Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3131 186TH PL NE_BLD1312_2026
RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address.3131 186TH PL NE Project Description-PHELPS Owner: CHERYL PHELPS Address. 3131 186TH PL NE City. ARLINGTON State.WA Zip Code: 98223 Phone. 206-227-2003 Entail:MEREDITH@CMHEATING.COM Applicant: CM HEATING Address: 1415 BROADWAY City. EVERETT State.WA Zip Code: 98201 Phone. 4252590550 Email: MEREDITH@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:CM HEALING Address: 1415 BROADWAY City. EVERETT State.WA Zip Code: 98201 License Number:CMHEAMH877DN Expiration. 5/2017 Phone: 4252590550 Email:MEREDITH@CMHEATING.COM STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #GDH80403AX AFUE80% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: [El Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date: 01/31/2017 Applicant Printed Name: MEREDITH GILBERT I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 Kristin Foster From: Meredith CM <meredith@cmheating.com> Sent: Wednesday, February 01, 2017 8:09 AM To: Kristin Foster Subject: Re: Cheryl Phelps Yes Meredith Gilbert 425-259-0550 x On Tue, Jan 31, 2017 at 5:02 PM, Kristin Foster<kfoster&arlin to�gov>wrote: Hello, Is the job located at 3131 186th Place NE for Cheryl Phelps a like-for-like furnace change out? Thanks Kristin Fo ste r Pe rm it Te c hnic ia n Community &Economic Development 360 403 3549 I kfoster(a�rlinetonwa.2ov HiNIUM FINALIST The Arlington/Darrington community has been selected as a finalist in the nationwide America's Best Communities competition. Read more here,and like our ABC Facebook nape 1 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON,WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:3131 186th Place NE Permit#:1312 Parcel#:00901400001800 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:PHELPS MATHEW A&CHERYL Name:CM Heating Name:CM Heating Inc Address:3131 186TH PL NE Address:1415 Broadway Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223-7890 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425.259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address:1415 Broadway Address: City,Slate,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC#: EXP: L1C#: EXP: JOB DESCRIPTION _ PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONsTRUC'I'ION AND IN DOING THE WORK AUTHORIZED TI IEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF TI IE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27, THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRCI 10. SALES TAX NOTICh::sales tax relating to construction and construction materials in the City of Arlin e{wrtcd on your sales tax return form and coded Ci ot'Arl'nglon#3101. Signature Print Name Date cleased By Date CONDITIONS Approved as submitted. Duct Testing is required per the 2015 Washington State Energy Code R402.4.1.2 THIS PERMIT AUTIIORIZS ONLY THE WORK NOTED THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC,)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 2/1/2017 Furnace $25.00 2/1/2017 Mechanical Permit Base Fee $25.00 2/1/2017 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following Information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 ` PHONE; (360) 403-3551 BUILDING PERMIT _ Address:3131 186th Place NE Permit#:1312 Parcel#:00901400001800 Valuation:0 00 OWNER APPLICANT CONTRACTOR Name:PHELPS MATHEW A&CHERYL Name:CM Heating Name:CM Heating Inc Address:3131 186TH PL NE Address:1415 Broadway Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223-7890 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address: 1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC 110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlin keporled on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date UV Ifeleascd By Date CONDITIONS Approved as submitted. Duct Testing is required per the 2015 Washington State Energy Code R402.4.1.2 THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 2/1/2017 Furnace $25.00 2/1/2017 Mechanical Permit Base Fee $25.00 2/1/2017 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon GMH81GDH8 L LGo co d m ai Jri Air Conditioning & Heating Two-STAGE CONVERTIBLE MULTI-SPEED GAS FURNACES 80%AFUE Contents Nomenclature........................................2 Product Specifications...........................3 Dimensions............................................5 Airflow Data...........................................7 Wiring Diagram....................................10 Accessories..........................................11 Minimum Filter Sizes ..........................11 Standard Features Cabinet Features • Heavy-duty aluminized-steel dual- • Multi-position installation: diameter,tubular heat exchanger GMH8: upflow, horizontal left or right • Two-stage convertible gas valve GDH8:dedicated downflow automatically adjust to high or low stage • Convenient left or right connection • Durable Silicon Nitride igniter for gas and electrical service • Quiet single speed draft inducer • Cabinet air leakage(QLeak)<_2% • Self-diagnostic control board • Heavy-gauge steel cabinet with with constant memory fault code durable baked-enamel finish • Color-coded low-voltage terminals with provisions • Fully insulated heat exchanger for electronic air cleaner and humidifier and blower section • Multi-speed blower motor • Low continuous fan speed options offer quiet air circulation • California Low NCx emissions standards models available OEM am, - *Complete warranty details available from your local dealer or at www.goodmanmfg.com.To receive the Lifetime Heat BBB Exchanger Limited Warranty(good for as long as you own your home),10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty,online registration must be completed within 60 days of installation.Online registration is not required in California or Quebec. SS-GMH8 www.goodmanmfg.com 10/15 Supersedes 5/14 NOMENCLATURE G M H 80 040 3 B X A A 1 2 4 5,6 7,8,9 10 11 12 13 14 Brand Minor Revision G-Goodman°Brand A-Initial Release B-First Revision Configuration C-Downflow/Horizontal Major Revision D-Dedicated Downflow A-Initial Release M-Upflow/Horizontal B-First Revision Gas Valve NOx E-Multi-Speed ECM N-Natural Gas H-Convertible Two-Stage,Single Phase X-Low NOx S-Single Stage,Single Speed Cabinet Width AFUE A-14" C-21" 80-80%AFUE B-17W' D-24M MBTU/h Maximum CFM 040-40,000 BTU/h 100-100,000 BTU/h 3-1200 CFM 060-60,000 BTU/h 120-120,000 BTU/h 4-1600 CFM 080-80,000 BTU/h 140-140,000 BTU/h 5-2000 CFM 2 www.goodmanmfg.com SS-G M H8 PRODUCT SPECIFICATIONS — GMH8 ICI I.I �.04: I:I I:I4: �:0 II I 4I HEATING CAPACITY Input 40,000 60,000 60,000 80,000 80,000 80,000 100,000 120,000 140,000 Natural Gas Output 32,000 48,000 48,000 64,000 64,000 64,000 80,000 96,000 112,000 LP Gas Output 32,000 48,000 48,000 64,000 64,000 64,000 80,000 96,000 96,000 AFUE' 80 80 80 80 80 80 80 80 80 Available AC @ 0.5"ESP 3 3 4 3 4 5 5 5 5 Temperature Rise Range(°F) 25-55 20-50 20-50 35-65 35-65 35-65 35-65 40-70 40-70 CIRCULATOR BLOWER Size (D x W) 10"x 6" 10"x 6" 10"x 8" 10"x 8" 10"x 8" 10"x 10" 10"x 10" 11"x 10" 11"x 10" Horsepower @1075 RPM %3 %3 Speed 4 4 4 4 4 4 4 4 4 Vent Diameter Z 4" 4" 4" 4" 4" 4" 4" 4" 4" No.of Burners 2 3 3 4 4 4 5 6 6 ELECTRICAL DATA Min.Circuit Ampacity 3 8.1 8.1 12.5 8.1 12.5 12.5 12.5 14.7 14.7 Max.Overcurrent Device(amps)° 15 15 15 15 15 15 15 15 15 SHIP WEIGHT(LBS) 86 90 98 106 107 114 118 132 132 ' DOE AFUE based upon Isolated Combustion System(ICS) z Vent and combustion air diameters may vary depending upon vent length.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA B149.1 and CAN/CSA B142.2(in Canada). 3 Minimum Circuit Ampacity=(1.25 x Circulator Blower Amps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. 4 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply. • Gas Service ConnectionYV'FPT • Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. SS-GMH8 www.goodmanmfg.com 3 PRODUCT SPECIFICATIONS - GDH8 0403A*Bl::l 0603A*B 080413*13 1005C*B HEATING CAPACITY Input 40,000 60,000 80,000 100,000 Natural Gas Output 32,000 48,000 64,000 80,000 LP Gas Output 32,000 48,000 64,000 80,000 AFUE' 80 80 80 80 Available AC @ 0.5"ESP 25-55 30-60 35-65 40-70 Temperature Rise Range ff) 3 3 4 5 CIRCULATOR BLOWER Size (DxW) 10X6 10X6 10X8 10X10 Horsepower @1075 RPM 1/3 1/3 1/2 3/4 Speed 4 4 4 4 Vent Diameter Z 4 4 4 4 No.of Burners 2 3 4 5 ELECTRICAL DATA Min.Circuit Ampacity s 8.5 8.5 12.9 12.9 Max.Overcurrent Device(amps)° 15 15 15 15 SHIP WEIGHT(LBS) 88 92 106 114 DOE AFUE based upon Isolated Combustion System(ICS) Vent and combustion air diameters may vary depending upon vent length.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA B149.1 and CAN/CSA B142.2(in Canada). a Minimum Circuit Ampacity=(1.25 x Circulator BlowerAmps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ° Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply. • Gas Service Connection W'FPT • Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. 4 www.goodmanmfg.com SS-G M H8 GMH8 DIMENSIONS Alternate Gas Inlet 13/<' A 17/16" B ® ® 0 33W Alt.Gas Inlet 27%6" High-Voltage Inlet 2U 235/16" Alt.High Voltage 0 Low-Voltage Inlet Alt.Low Voltage I� 2 33/4' _ GMH80403A*B 14" 12%2" 7GMH812rO5D*B 21" 19%2" GMH80603A*B 14" 12%" 21" 19%" GMH80604B*B 17%" 16" 24%" 23" GMH80803B*B 17%" 16" GMH81405D*B 24%" 23" GMH80804B*B 17%" 16" Notes • Line voltage wiring and low-voltage wiring can enter through the right or left side of furnace. • Conversion kits for high-altitude(4500+ft)natural gas operation are available.Contact your Goodman distributor or dealer for details. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS VENT' SIDES REAR FRONT' TOP SW B 1" 0" 3" 6" 1" 1" 24"clearance for serviceability recommended. ' Single Wall Vent(SW)to be used only as a connector.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA 3149.1 and CAN/CSA 3142.2(in Canada). Note:GMH8 approved for line contact in the horizontal position. SS-GMH8 www.goodmanmfg.com 5 GDH8 DIMENSIONS 4 28" A 19%g B High-Voltage Electrical Low-Voltage , Electrical O 00 Gas Inlet W 33%" O 18%" o 0 0 . . 1 000 MODELNON-COMBUSTIBLE ... BASE GDH80403A*B 14" 12%" SBT14 GDH80603A*B 14" 12%" SBT14 G DH80804B*B 17%" 16" SBT17 GDH81005C*B 21" 19%" SBT21 NOTES • Line voltage wiring and low-voltage wiring can enter through the right or left side of furnace. • Conversion kits for high-altitude(4500+ft)natural gas operation are available.Contact your Goodman distributor or dealer for details. • Installer must supply the following gas line fittings,according to which entrance is used: 0 Left:One 909 street elbow;one 2A"pipe nipple;one 909 elbow;straight pipe;one ground joint union 0 Right:Straight pipe to reach gas valve MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS VENT' SIDES REAR FRONT' TOP SW B 1" 0" 3" 6" 1" 1" ' 24"clearance for serviceability recommended. z Single Wall Vent(SW)to be used only as a connector.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA 6149.1 and CAN/CSA 3142.2(in Canada). 6 www.goodmanmfg.com SS-G M H8 GMH8 AIRFLOW DATA (CFM&TEMPERATURE RISE vs.EXTERNAL STATIC PRESSURE) M OTOR TONS EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) ICFM RISE C� CFM RISE CFM I RISE CFM I RISE CFM CFM CFM High 3 1,521 --- 1,466 --- 1,414 --- 1,373 --- 1,298 --- 1,243 1,164 1,075 GMH8 Med 2.5 1,160 26 1,160 26 1,132 26 1,121 26 1,082 27 1,042 997 925 0403A*B Med-Lo 2 961 31 955 31 948 31 932 32 913 33 882 821 803 Low 1.5 781 38 785 38 781 38 773 38 761 32 745 716 668 High 3 1,422 31 1,352 33 1,307 34 1,197 37 1,157 38 1,092 1,075 983 GMH8 Med 2.5 1,098 40 1,081 41 1,051 42 1,039 43 1,021 44 983 924 868 0603A*B Med-Lo 2 919 48 913 49 892 50 847 ---- 829 ---- 818 792 728 Low 1.5 758 ---- 741 -- 741 -- 733 ---- 699 ---- 677 649 626 High 4 2,134 21 2,100 21 2,042 22 1,975 23 1,883 24 1,786 1,700 1,601 GMH8 Med 3.5 1,668 27 1,663 27 1,656 27 1,645 27 1,616 28 1,549 1,492 1,391 060413*13 Med-Lo 3 1,419 31 1,426 31 1,426 31 1,432 31 1,419 31 1,378 1,328 1,261 Low 2.5 1,134 39 1,145 39 1,166 38 1,171 38 1,160 38 1,144 1,111 1,071 High 3 1,607 37 1,572 38 1,547 39 1,498 40 1,448 41 1,390 1,302 1,222 GMH8 Med 2.5 1,159 51 1,156 51 1,145 52 1,127 53 1,108 53 1,075 1,033 957 080313*13 Med-Lo 2 938 63 916 65 916 65 900 ---- 889 ---- 865 829 785 Low 1.5 785 ---- 766 -- 743 ---- 730 ---- 709 ---- 683 666 604 High 4 2,051 ---- 1,983 ---- 1,895 --- 1,812 --- 1,725 --- 1,627 1,530 1,439 GMH8 Med 3.5 1,736 --- 1,708 35 1,652 36 1,611 37 1,540 38 1,475 1,394 1,307 080413*13 Med-Lo 3 1,493 35 1,668 36 1,459 41 1,429 41 1,389 43 1,339 1,274 1,204 Low 2.5 1,200 49 1,185 50 1,180 50 1,173 51 1,158 51 1,125 1,125 1,080 High S 2,290 ---- 2,229 ---- 2,155 ---- 2,047 ---- 1,960 ---- 1,837 1,712 1,584 GMH8 Med 4 1,852 --- 1,820 --- 1,777 --- 1,719 --- 1,641 36 1,567 1,469 1,382 0805C*B Med-Lo 3.5 1,615 37 1,592 37 1,556 38 1,516 39 1,470 40 1,405 1,346 1,235 Low 3 1,290 46 1,285 46 1,265 47 1,235 48 1,214 49 1,174 1,044 904 High S 2,323 --- 2,225 --- 2,120 35 2,040 36 1,974 38 1,801 1,688 1,577 GMH8 Med 4 1,858 40 1,847 40 1,799 41 1,744 42 1,674 44 1,577 1,493 1,399 1005C*B Med-Lo 3.5 1,596 46 1,587 47 1,571 47 1,552 48 1,493 50 1,397 1,326 1,217 Low 3 1,291 57 1,272 58 1,261 59 1,257 59 1,205 61 1,168 1,118 1,060 High S 2,469 --- 2,389 --- 2,300 --- 2,223 40 2,131 42 2,027 1,902 1,786 GMH8 Med 4 1,575 56 1,558 57 1,545 58 1,513 59 1,500 59 1,419 1,354 1,271 1205D*B Med-Lo 3.5 1,402 63 1,380 64 1,343 66 1,319 67 1,296 69 1,245 1,183 1,106 Low 3 1,200 ---- 1,186 ---- 1,161 ---- 1,127 ---- 1,082 ---- 1,042 995 926 High S 2,469 42 2,389 43 2,300 45 2,223 47 2,131 49 2,027 1,902 1,786 GMH8 Med 4 1,575 66 1,558 67 1,545 67 1,513 69 1,500 69 1,419 1,354 1,271 1405D*C Med-Lo 3.5 1,402 ---- 1,380 ---- 1,343 ---- 1,319 ---- 1,296 ---- 1,245 1,183 1,106 Low 3 1,200 ---- 1,186 ---- 1,161 ---- 1,127 ---- 1,082 ---- 1,042 995 926 @ 0.5"ESP NOTES • CFM in chart is without filter(s).Filters do not ship with this furnace,but must be provided by the installer.If the furnace requires two return filters,this chart assumes both filters are installed. • All furnaces ship as high-speed cooling and medium-speed heating.Installer must adjust blower cooling and heating speed as needed. • For most jabs,400 CFM per ton for cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • This chart is for information only. For satisfactory operation,external static pressure should not exceed value shown on the rating plate. • The dashed(----)areas indicate a temperature rise not recommended for this model. • At higher altitudes,a properly derated unit will have approximately the same temperature rise at a particular CFM,while ESP at the CFM will be lower. SS-GMH8 www.goodmanmfg.com 7 GDH8 AIRFLOW DATA (CFM&TEMPERATURE RISE vs.EXTERNAL STATIC PRESSURE) R TONS MOT'0i EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN)High 3.0 1,353 --- 1,290 --- 1,246 --- 1,199 25 1,149 26 1,116 1,116 1,099 GDH8 Med 2.5 1,183 25 1,113 27 1,098 27 1,052 28 1,039 29 1,006 1,012 969 0403A*B (Med)2 Med-Lo 2.0 980 30 946 31 920 32 900 33 896 33 885 855 804 Low 1.5 778 38 762 39 738 40 746 40 738 40 717 696 678 High 3.0 1,290 34 1,236 36 1,194 37 1,166 38 1,176 38 1,166 1,108 1,029 GDH8 Med 2.5 1,139 39 1,090 41 1,035 43 1,063 42 1,063 42 1020 962 895 0603A*B (Med)2 Med-Lo 2.0 962 46 927 48 925 48 941 47 909 49 877 834 779 Low 1.5 787 56 776 57 763 58 744 60 723 --- 690 641 581 High 4.0 2,128 --- 2,063 --- 2,001 --- 1,927 --- 1,824 --- 1,726 1,628 1,529 GDH8 Med 3.5 1,840 --- 1,788 --- 1,745 --- 1,689 35 1,625 36 1,550 1,470 1,364 08046*B (Med)2 Med-Lo 3.0 1,602 37 1,558 38 1,543 38 1,493 40 1,455 41 1,402 1,328 1,239 Low 2.5 1,277 46 1,252 47 1,244 48 1,229 48 1,214 49 1,179 1141 1079 High 5.0 2,405 --- 2,361 --- 2,250 --- 2,161 --- 2,037 36 1,937 1,808 1,689 GDH8 Med 4.0 1,880 39 1,838 40 1,794 41 1,734 43 1,677 44 1,568 1,510 1,401 1005C*B (Med)2 Med-Lo 3.5 1659 45 1,630 45 1,587 47 1,537 48 1,492 50 1,445 1,368 1,287 Low 3.0 1,472 50 1,454 51 1,404 53 1,366 54 1,326 56 1300 1228 1139 Heating speed as shipped z @ 0.5"ESP NOTES • CFM in chart is without filter(s).Filters do not ship with this furnace,but must be provided by the installer.If the furnace requires two return filters,this chart assumes both filters are installed. • All furnaces ship as high-speed cooling and medium-speed heating.Installer must adjust blower cooling and heating speed as needed. • For most jobs,400 CFM per ton for cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • This chart is for information only. For satisfactory operation,external static pressure should not exceed value shown on the rating plate. • The dashed(----)areas indicate a temperature rise not recommended for this model. • At higher altitudes,a properly derated unit will have approximately the same temperature rise at a particular CFM,while ESP at the CFM will be lower. 8 www.goodmanmfg.com SS-G M H8 TEMPERATURE RISE RANGE CHART O = O x - W LL = O U Q r = O D m °° - G U - II p x O j \ LL Q LL m U _ O p - N O V = W - N Lu VLL - C)U O O O - Q O N p� oo N X w CD O d coo-0 LU o - rn m o - vi 0 - > o a ~ N NN N. - O ~ a - ~ 00 -col - - 0 o - \ rn = O � oo - m o - o - LL - U - O o - (0 co - VM O L() O - O co O O O O O O O O O CO O O ti c9 Ln It M N 3SI�j 3uniVU3dW31 SS-GMH8 www.goodmanmfg.com 9 WIRING DIAGRAM WARNING:DISCONNECT POWER BEFORE I———————— HUMIDIFIER — . INTEGRATED SERVICING.WIRING TO UNIT MUST BE I ---- CONTROL MODULE PROPERLY POLARIZED AND GROUNDED. I I XFMR(5) GND 2 VAC GND(8) HUMIDIFIER GAS i MVC(9) HI VALVE MVH(12) J I MVL(2) Mi R I I BLOWER AUXILIARY I PRESSURE LIMIT CONTROLS SWITCH C G R AUTO mSMIN 1N05ZG0 y G PS(10) C NO 1 STG a2 STG MODE 1 P50(4) 111 SEC m 100 SEC V =T0 10g� 2 O'cFp 0MICRO)HLI(7) HLO(1) FUSE O I II I AUTO RESET O R PRIMARY SEE NOTE fimy IR02(11) LIMIT CONTROL _ AUXILIARY () BR LIMITS INTEGRATED 2 I R01(5) N N CONTROL MODULE i MANUAL RESET ROLLOUT J LIMIT CONTROLS) CL FS XFMR(3) (SINGLE CONTROL ON SOME MODELS) O O i 24 VAC p- 40 VA 0 O BL BR TRANSFORMER J 3 RD � C o ON XFMR-H 115 VAC XFMR-N _ C 2 r0 FLAME SENSOR O J ` O W m FP Y O. HOT SURFACE IGNITER oD tl�D C N XFMR-H LINE-H EAC-H I IGN IGN-N m m 2_ c1 ID m$m `p w BK o- INU I BLWR p m O` ND-N 0 U O BK AxFMR ro i u m� O O COOL- CIRCULATOR O 5 0 BLWR CIR-N E AA A A FfS� O WH O O BK ELECTRONIC _ a OR 15 PIN PLUG EAC-H AIR CLEANER % _ ON SOME MODELS �•--- ICI N - N .- BLOWERCOMPARTMENT LINE-H LINE-N ly ______ u -------- ----------- ---------- N BURNER COMPARTMENT JUNCTION BOX C C N DOOR SWITCH 24 VAC DOOR HUMIDIFIER SWITCH SWITCH LOCATED IN BLOWER / OHO T T 0 O. COMPARTMENTON SOME MODELS I I �[^_—l.^,y^,', o WARNING: I I m > RD V D m DISCONNECT POWE j I DISCONNECT a+ ���/ vL BEFORE SERVICING PRESSURE YL O SWITCH PRIMARY LIMIT WIRING TO UNIT I L RD MUST BE I tw J YL PROPERLY I = O YL POLARIZED I I W AND GROUNDED. — BK L GND N Uj BR BL OVERCURRENT PROTECTION DEVICE z WH z BK PM C HI JUNCTION VICT 1 2 3 BOX SURFACE 2STAGE - LINE-N IGNITER GAS VALVE (HONEY WELL) (� - GND PU - LINE H a INDUCED DRAFT BLOWER TO 115VAC/1/50HZ pip pU POWER SUPPLY WITH FLAME OVERCURRENT PROTECTION N ROLLOUT LIMITS SENSOR DEVICE (SINGLE CONTROL ON SOME MODELS) 3 0 STEADY ON=NORMAL OPERATION Q E 3 OFF =CONTROL FAILURE LOW VOLTAGE(24V) EQUIPMENT GND /}j o°/n m m EEB 1 1 FLASH = SYSTEM LOCKOUT(RETRIES/RECYCLES EXCEEDED) LOW VOLTAGE FIELD ——— FIELD GND 1 t m O u is 17, 2 2 FLASHES=PRESSURE SWITCH STUCK CLOSED HI VOLTAGE(115V) «o, w fl- 3 3 FLASHES=PRESSURE SWITCH STUCK OPEN FIELD SPLICE �, .J. HI VOLTAGE FIELD y .— o 4 4 FLASHES=OPEN HIGH LIMIT SWITCH(TEMP.) ---Fa : 3 £ 5 5 FLASHES=FLAME SENSE WITHOUT GAS VALVE JUNCTION IGNITER mLr m« TERMINAL � '=' O w s 6 FLASHES=OPEN ROLLOUT OR OPEN FUSEpD SWITCH(PRESS.) 7 7 FLASHES=LOW FLAME SIGNAL INTERNAL TO _ INTEGRATED CONTROL OVERCURRENT v e 8 FLASHES=CHECK IGNITER OR IMPROPER GROUND OVERCURRENT DEVICE 3 J C RAPID FLASHES=REVERSED 115 VAC POLARITYNERIFY GND PLUG CONNECTION NOTES: COLOR CODES: PK PINK 1.SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2.MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. YL YELLOW BR BROWN 3.IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE OR ORANGE WH WHITE REPLACED,IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE PU PURPLE BL BLUE RATING OF AT LEAST 105 C.USE COPPER CONDUCTORS ONLY. GR GREEN GY GRAY 4.BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE BK BLACK RD RED CORRECT COOLING CFM.(SEE SPEC SHEET FOR AIR FLOW CHART) 5,UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C.AND LOCAL CODES, 6.TO RECALL THE LAST 5 FAULTS,MOST RECENT TO LEAST RECENT,DEPRESS SWITCH 0140F00662 REV.A FOR MORE THAN 2 SECONDS WHILE IN STANDBY(NO THERMOSTAT INPUTS). 10 www.goodmanmfg.com SS-G M H8 ACCESSORIES MODELDESCRIPTION 141 1.1 1.14: 181 1814: 181 11 1 • 41 • LPM-06 LP Conversion Kit(Springs&Orifice)' V V V d V V V V V HANG20 High-Altitude Natural Gas Kit(4500+ft) V V V V V V V V V FTK04 Twinning Kit V V V V V V V V V MVK-011 Masonry Vent Kits V V V V MVK-022 Masonry Vent Kits V V AFE18-60A Fossil Fuel Kit V V V V V V V V V ' Honeywell or White-Rodgers valves S Upflow applications only MODEL DESCRIPTION GDH8 1 141 1.1 1814 11 LPM-06 LP Conversion Kit(Springs&Orifice)' V V d V HANG20 High-Altitude Natural Gas Kit(4500+ft) V V d V FTK04 Twinning Kit V V V V AFE18-60A Fossil Fuel Kit V V V V SBT 14/17/21* Downflow Sub-base V d V V ' Honeywell or White-Rodgers valves GMH8 MINIMUM FILTER SIZES MODEL 141 1.1 1.1�: 1:1 1:14: 1:1 11 1 • 41 . Filter Size(in (1)16 x 25(Side)7or (1)16 x 25(Side or Bottom) (1)16 x 25 (2)16 x 25(Side)or (2)16 x 25(Side)or (1)14 x 24(Botto (Side or Bottom)' (1)20 x 25(Bottom) (1)24 X 24(Bottom) Note: Other size filters of equal or greater surface area may be used;filters may also be centrally located. Use 2-16 x 25 filters on side returns or 20 x 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. GDH8 MINIMUM FILTER SIZES MODEL1 :141 • :1.1 1 :1:14: . 11 Filter Size(inZ) (2)10 x 20 or(1)14 x 25 Top Return (2)14 x 20 or (2)14 x 20 or (1)16 x 25 Top Return (1)20 x 25 Top Return Note: Other size filters of equal or greater surface area may be used;filters may also be centrally located. SS-GMH8 www.goodmanmfg.com 11 NOTES Goodman Manufacturing Company,L.P.,reserves the right to discontinue,or change at any time,specifications or designs without notice or without incurring obligations.©2015 Goodman Manufacturing Company,L.P. • Houston,Texas • Printed in the USA. 12 www.goodmanmfg.com SS-G M H8 CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON,WA.98223 PHONE; (360)403-3551 BUILDING PERMIT Address:3131 186th Place NE Permit#:1312 Parcel#:00901400001800 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:PHELPS MATHEW A&CHERYL Name:CM Heating Name:CM Heating Inc Address:3131 186TH PL NE Address:1415 Broadway Address:1415 Broadway City,Stale Zip:ARLINGTON,WA 98223-7890 City,Stale Zip:Everett,WA 98201 City,Slate Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address:1415 Broadway Address: City,Slate,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREF TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCrION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF TILE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 182T THIS APPLICATION lS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HISMER DEPUTY AND ALL FEES ARE PAID. IT 1S UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10ARCI 10. S,%I.I,,S TAX NtyrlQ,',i Sales tax relating to construction and construction materials in the City ofAritn cportcd on your sales tax return form and coded CILV ol'Arl'n tun#3101. Signature Print Name Date cecased By Date CONDITIONS Approved as submitted. Duct Testing is required per the 2015 Washington State Energy Code R402.4.1.2 THIS PERMIT AUTI IORIZS ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC,)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 2/1/2017 Furnace $25.00 2/1/2017 Mechanical Permit Base Fee $25.00 2/1/2017 Processing/Technology Fee $25.00 Total Due: S75.00 Total Payment: $75.00 Balance Due: S0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following Information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon �\ 1 CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:3131 186th Place NE Permit#:1312 Parcel#:00901400001800 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:PHELPS MATHEW A&CHERYL Name:CM Heating Name:CM Heating Inc Address:3131 186TH PL NE Address:1415 Broadway Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223-7890 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address: 1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRCI I0. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlin &eorled on your sales tax return form and coded City of Arlington#3101. ' 2• A.2-DI�1 Signature Print Name Date 'leased By Date CONDITIONS Approved as submitted. Duct Testing is required per the 2015 Washington State Energy Code R402.4.1.2 THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 2/1/2017 Furnace $25.00 2/1/2017 Mechanical Permit Base Fee $25.00 2/1/2017 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit Information Date 1/31/2017 Permit Number 1312 Project Name Phelps Applicant Name CM Heating Applicant Address 1415 Broadway City,State,Zip Everett,WA 98201 Contact Meredith Gilbert Phone 425-259-0550 Email meredith@cmheating.com Permit Type Residential Mechanical Site Address 3131 186th Place NE Valuation 0.00 Status Issued Permit Issued 2/1/2017 Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use Replace gas furnace Assigned To Kristin Foster Property Information Owner Information Parcel#:00901400001800 PHELPS MATHEW A&CHERYL PHELPS MATHEW A&CHERYL 3131 186TH PL NE 3131 186TH PL NE ARLINGTON,WA 98223-7890 Contractors Contractor Primary Phone Email Contractor Type License License# Name Contact Meredith 125-259 MECHANICAL Labor& CMHEAMH877DN �M Heating Inc Silbert )550 neredith@cmheating.com CONTRACTOR Industries Fees Fee Description Notes Amount Furnace 322.10.00.00 $25.0 Mechanical Permit Base Fee 322.10.00.00 $25.0 Processing/Technology Fee 341.43.00.02 $25.0 TotaQ $75.0 Payments Date IPaid By Amount Description Pa ment T pe Accepted B 2/1/2017 DEBORAH BAUERS $75.00 3334367 Tota $75.00 Amount Outstanding $0.0 Uploaded Files Upload File Date File Uploaded B 2/1/2017 9:06:51 AM '1.312 _Issued Permit-Of Foster, Kristin 2/1/2017 8:24:26 AM 1312 Email-Like-fo_r-Lik_e_Change Out.pdf Foster, Kristin 2/l/2017 8:23:10 AM 1312 S ecs pdf Foster, Kristin 2/1/2017 8:23:10 AM 1312 Application.pdf Foster, Kristin Kristin Foster From: Meredith CM <meredith@cmheating.com> Sent: Wednesday, February 01,2017 8:09 AM To: Kristin Foster Subject: Re: Cheryl Phelps Yes Meredith Gilbert 425-259-0550 On Tue, Jan 31, 2017 at 5:02 PM,Kristin Foster<kfosterna arlin onwa.gov>wrote: Hello, Is the job located at 3131 186 h Place NE for Cheryl Phelps a like-for-like furnace change out?Thanks Kristin Foster Permit Technician Community 8 Economic Development 360 403 3549 ktoster@adinatonwa.aov FIAIi Misr The Arlington/Darrington community has been selected as a finalist in the nationwide America's Best Communities competition. Read more here,and like our ABC Facebook aaQe 1 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:3131 186TH PL NE Project Description:PHELPS Owner: CHERYL PHELPS Address: 3131 186TH PL NE City.ARLINGTON State WA Zip Code: 98223 Phone: 206-227-2003 Email:MEREDMi@CMHEATING.COM Applicant: CM HEATING Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 Phone: 4252590550 Email: MEREDMi@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name•CM HEATING Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 License Number:CMHEAMH877DN Expiration: 5/2017 Phone:4252590550 Email:MEREDrrH@CMHEATING.COM STAFF USE ONLY Received Permit#: Accepted by: Date: JAN 31 2017 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model#GDH80403AX AFUE80% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove Fire Place Insert C Outdoor BBQ ❑ Gas Piping Solid-Fuel Appliance L Other Gas Piping Information Not Applicable: Q Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date: 01/31/2017 Applicant Printed Name: MEREDITH GILBERT I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 2/1/2017 C M HEATING INC [lrnne Espanol Contact (Search L&I \-Z Index Help ldy[is;l Safety&Health Claims &Insurance Workplace Rights Trades&Licensing Washington State Department of " Labor & Industries C M HEATING INC Owner or tradesperson 1415 BROADWAY EVERETT,WA 98201 Principals 425-259-6666 Gamer,James N, PRESIDENT SNOHOMISH County Umayam,John A,VICE PRESIDENT Umayam,Antonio(Tony)G,SECRETARY Umayam,Antonio(Tony)G,TREASURER Gamer,James N,AGENT Gamer, Paul,PRESIDENT (End:06/29/2016) Gamer, Kathleen D,SECRETARY (End:06/29/2016) Gamer,Kathleen D,TREASURER (End:06/29/2016) Doing business as C M HEATING INC WA UBI No. Business type 601 114 652 Corporation Governing persons JAMES GARNER KATHLEEN GARNER; PAUL M GARNER; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. CMHEAMH877DN Effective—expiration 03/15/2013—03/15/2017 Designated administrator Active. Giacomi,John Meets current requirements. License type License no. Electrical Administrator GIACOJ*840MG Bond Contractors Bonding&Insurance Co $4,000.00 Bond account no. SC6810 Received by L&I Effective date Help us improve https://secure.Ini.wa.gov/verify/Detaii.aspx?UBI=601114652&LIC=CM HEAM H877D N&SAW= 1/2 2/1/2017 C M HEATING INC 03/15/2013 02/28/2000 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 490,794-M Doing business as CHIMNEY MASTERS Estimated workers reported Quarter 4 of Year 2016"31 to 50 Workers" L&I account representative T4/JULIE SUR(360)9024825-Email:SURJ2350ni.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/16/2015 No violations Inspection no. 317935327 Location 1415 Broadway Everett,WA 98201 Inspection results date 08/01/2011 Violations Inspection no. 315054981 Location 912 Rucker Everett,WA 98201 ©Washington State Dept.of Labor&Industries.Use of this site is subject to the laws or the state of Washington. Help us improve https://secure.Ini.wa.gov/verity/Detail.aspx?U B1=601114652&LIC=C M H EAM H877D N&SAW= 2/2 GMH8/GDH8 Air Conditioning& Heating TWO STAGE CONVERTIBLE MULTI SPEED GAS FURNACES 80%AFUE Contents Nomenclature........................................2 Product Specifications...........................3 Dimensions............................................5 Airflow Data...........................................7 Wiring Diagram....................................10 Accessories..........................................11 Minimum Filter Sizes ..........................11 Standard Features Cabinet Features • Heavy-duty aluminized-steel dual- • Multi-position installation: diameter,tubular heat exchanger GMH8:upflow,horizontal left or right • Two-stage convertible gas valve GDH8:dedicated downflow automatically adjust to high or low stage • Convenient left or right connection • Durable Silicon Nitride igniter for gas and electrical service • Quiet single speed draft inducer • Cabinet air leakage(QLeak)<_2% • Self-diagnostic control board • Heavy-gauge steel cabinet with with constant memory fault code durable baked-enamel finish • Color-coded low-voltage terminals with provisions • Fully insulated heat exchanger for electronic air cleaner and humidifier and blower section • Multi-speed blower motor • Low continuous fan speed options offer quiet air circulation • California Low NCx emissions standards models available AM- •Complete warranty details available from your local dealer or at www.goodmanmfg.com.To receive the Lifetime Heat BBB Exchanger Limited Warranty(good for as long as you own your home),10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty,online registration must be completed within 60 days of installation.Online registration is not required in California or Quebec. SS-GMH8 www.goodmanmfg.com 10/15 Supersedes 5/14 NOMENCLATURE G M H 80 040 3 B X A A 1 2 4 5,6 7,8,9 10 11 12 13 14 J_ Brand Minor Revision G-Goodman®Brand A-Initial Release B-First Revision Configuration C-Downflow/Horizontal Major Revision D-Dedicated Downflow A-Initial Release M-Upflow/Horizontal B-First Revision Gas Valve NOx E-Multi-Speed ECM N-Natural Gas H-Convertible Two-Stage,Single Phase X-Low NOx S-Single Stage,Single Speed Cabinet Width AFUE A-14" C-21" 80-80%AFUE 8-17%" D-24344" MBTU/h Maximum CFM 040-40,000 BTU/h 100-100,000 BTU/h 3-1200 CFM 060-60,000 BTU/h 120-120,000 BTU/h 4-1600 CFM 080-80,000 BTU/h 140-140,000 BTU/h 5-2000 CFM 2 www.goodmanmfg.com SS-GMHB Ph.OUCT SPECIFICATIONS- GMHS HEATING CAPACITY Input 40,000 60,000 60,000 80,000 80,000 80,000 100,000 120,000 140,000 Natural Gas Output 32,000 48,000 48,000 64,000 64,000 64,000 80,000 96,000 112,000 LP Gas Output 32,000 48,000 48,000 64,000 64,000 64,000 80,000 96,000 96,000 AFUE' 80 80 80 80 80 80 80 80 80 Available AC @ 0.5"ESP 3 3 4 3 4 5 5 5 5 Temperature Rise Range(•F) 25-55 1 20-50 20-50 35-65 35-65 35-65 35-65 1 40-70 40-70 CIRCULATOR BLOWER Size (DxW) 10"x6" 10"x6" 10"x8" 10"x8" 10"x8" 10"x10" 10"x10" 11"x10" 11"x10" Horsepower @1075 RPM % % %2 %3 % %: % % '/< Speed 4 4 4 4 4 4 4 4 4 Vent Diameter 2 4" 4" 4" 4" 4" 4" 4" 4" 4" No.of Burners 2 3 3 4 4 4 1 5 6 6 ELECTRICAL DATA Min.Circuit Ampacity 3 8.1 8.1 12.5 8.1 12.5 12.5 12.5 14.7 14.7 Max.Overcurrent Device(amps)° 15 15 1 15 15 15 15 15 15 15 SHIP WEIGHT(LBS) 1 86 90 98 1 106 1 107 114 118 1 132 132 ' DOE AFUE based upon Isolated Combustion System(ICS) Vent and combustion air diameters may vary depending upon vent length.Referto the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA B149.1 and CAN/CSA B142.2(in Canada). Minimum Circuit Ampacity=(1.25 x Circulator Blower Amps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. 4 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.May use fuses or HACR-type circuit breakers of the same size as noted - Nores • All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply. • Gas Service Connection"FPT • Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. SS-GMH8 www.goodmanmfg.com 3 PRODUCT SPECIFICATIONS-GUH8 I 0.I I:I4: I0 HEATING CAPACITY Input 40,000 60,000 80,000 100,000 Natural Gas Output 32,000 48,000 64,000 80,000 LP Gas Output 32,000 48,000 64,000 80,000 AFUE' 80 80 80 80 Available AC @ 0.5"ESP 25-55 30-60 35-65 40-70 Temperature Rise Range(°F) 3 3 4 5 CIRCULATOR BLOWER Size (DxW) 10X6 10X6 1OX8 10X10 Horsepower @1075 RPM 1/3 1/3 1/2 3/4 Speed 4 4 4 4 Vent Diameter 2 4 4 4 4 No.of Burners 2 3 4 5 ELECTRICAL DATA Min.Circuit Ampacity a 8.5 8.5 12.9 12.9 Max.Overcurrent Device(amps)4 15 15 15 15 SHIP WEIGHT(LBS) 88 92 106 114 i DOE AFUE based upon Isolated Combustion System(ICS) 1 Vent and combustion air diameters may vary depending upon vent length.Referto the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/GSA B149.1 and CAN/CSA B142.2(in Canada). Minimum Circuit Ampacity=(1.25 x Circulator Blower Amps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. • Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply. • Gas Service Connection%"FPT • Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. 4 www.goodmanmfg.com SS-GMH8 GMH8 DIMENSIONS Altemate Gas Inlet ®® O Alt.Gas Inlet 2T/e" High-Voltage Inlet 20° 23s/,6 Alt.High Voltage 0 13e/.° Low-Voltage Inlet Alt.Low Voltage t '/° 28° MODEL7GMH81005C*B GMH80403A*B 14" 12%2" 21" 19'/" GMH80603A*B 14" 12%2" 21" 19'/2" GMH80604B*B 17%2" 16" 24%2" 23" GMH80803B*B 17%" 16" GMH81405D*B 24'/" 23" GMH80804B*B 17%" 16" Notes • Line voltage wiring and low-voltage wiring can enter through the right or left side of furnace • Conversion kits for high-altitude(4500+ft)natural gas operation are available.Contact your Goodman distributor or dealer for details. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS VENT= SIDES REAR FRONT' SW B TOP 1" 0" 3" 6" ' 24"clearance for serviceability recommended. 2 Single Wall Vent(SW)to be used only as a connector.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA 8149.1 and CAN/CSA 13142.2(in Canada). Note:GMH8 approved for line contact in the horizontal position SS-GMH8 www.goodmanmfg.com 5 GDH8 DIMENSIONS 28" A 19%" B High-Voltage Electrical Low-Voltage Electrical O • 00 Gas Inlet 33 Y." 18%" 0 o� ooc MODELB NON-COMBUSTIBLE ••• BASE GDH80403A*B 14" 12Y22" SBT14 GDH80603A*B 14" 12%2" SBT14 GDH80804B*B 17%2" 16" SBT17 GDH81005C*B 21" 19%" SBT21 NOTES • Line voltage wiring and low-voltage wiring can enter through the right or left side of furnace • Conversion kits for high-altitude(4500+ft)natural gas operation are available.Contact your Goodman distributor or dealer for details. • Installer must supply the following gas line fittings,according to which entrance is used: 0 Left:One 909 street elbow;one 2%"pipe nipple;one 909 elbow;straight pipe;one ground joint union 0 Right:Straight pipe to reach VS valve MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS VENT'SIDES REAR FRONTt TOP Sw B J. C1" 3„ 6" 24"clearance for serviceability recommended. t Single Wall Vent(SW)to be used only as a connector.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA 13149.1 and CAN/CSA B142.2(in Canada). 6 www.goodmanmfg.com SS-GMH8 GMHS AIRFLOw DATA (CFM&TEMPERATURE RISE v5.EXTERNAL STATIC PRESSURE) MODELExTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) CFM I RISE CFM I RISE CFM I RISE CFM RISE CFM I RISE CFIVI CFM CFM High 3 1,521 -- 1,466 -- 1,414 - 1,373 --- 1,298 -- 1,243 1,164 1,075 GMH8 Med 2.5 1,160 26 1,160 26 1,132 26 1,121 26 1,082 27 1,042 997 925 0403A*B Med-Lo 2 961 31 955 31 948 31 932 32 913 33 882 821 803 Low 1.5 781 38 78S 38 781 38 773 38 761 32 745 716 668 High 3 1,422 31 1,352 33 1,307 34 1,197 37 1,157 38 1,092 1,07S 983 GMH8 Med 2.5 1,098 40 1,081 41 1,051 42 1,039 43 1,021 44 983 924 868 0603A*B Med-Lo 2 919 48 913 49 892 5o 847 - 829 -- 818 792 728 Low 1.5 758 - 741 -- 741 - 733 - 699 - 677 649 626 High 4 21134 21 2,100 21 2,042 22 1,975 23 1,883 24 1,786 1,700 1,601 GMH8 Med 3.5 1,668 27 1,663 27 1,656 27 1,645 27 1,616 28 1,S49 1,492 1,391 0604E*B Med-Lo 3 1,419 31 1,426 31 1,426 31 1,432 31 1,419 31 1,378 1,328 1,261 Low 2.5 1,134 39 1,145 39 1,166 38 1,171 38 1,160 38 1,144 1,111 1,071 High 3 1,607 37 1,572 38 1,547 39 1,498 40 1,448 41 1,390 1,302 1,222 GMH8 Med 2.5 1,159 51 1,156 51 1,145 52 1,127 53 1,108 53 1,07S 1,033 957 0803B*B Med-Lo 2 938 63 916 65 916 65 900 -- 889 - 865 829 78S Low 1.5 785 -- 766 - 743 -- 730 - 709 - 683 666 604 High 4 2,051 - 1,983 -- 1,895 - 1,812 --- 1,725 - 1,627 1,530 1,439 GMH8 Med 3.5 1,736 --- 1,708 35 1,652 36 1,611 37 1,540 38 1,475 1,394 1,307 0804B*B Med-Lo 3 1,493 35 1,668 36 1,459 41 1,429 41 1,389 43 1,339 1,274 1,204 Low 2.5 1,200 49 1 1,185 50 1,180 SO 1,173 51 1,158 S1 1,125 1,125 1,080 High 5 2,290 - 2,229 - 2,155 - 2,047 -- 1,960 ---- 1,837 1,712 1,584 GMH8 Med 4 1,852 -- 1,820 -- 1,777 - 1,719 -- 1,641 36 1,567 1,469 1,382 0805C*B Med-Lo 3.S 1,615 37 1,592 37 1,556 38 1,516 39 1,470 40 1,405 1,346 1,235 Low 3 1,290 1 46 1,285 46 1,265 47 1,23S 48 1,214 49 1,174 1,044 904 High 5 2,323 -- 2,225 - 2,120 35 2,040 36 1,974 38 1,801 1,688 1,S77 GMH8 Med 4 1,8S8 40 1,847 40 1,799 41 1,744 42 1,674 44 1,577 1,493 1,399 1005C*B Med-Lo 3.5 1,596 46 1,587 47 1,571 47 1,552 48 1,493 50 1,397 1,326 1,217 Low 3 1,291 S7 1 1,272 58 1,261 59 1,257 59 1,20S 61 1,168 1,118 1,060 High S 2,469 -- 2,389 --- 2,300 --- 21223 40 2,131 42 2,027 1,902 1,786 GMH8 Med 4 1,57S 56 1,558 57 1,545 58 1,513 59 1,500 59 1,419 1,354 1,271 1205D*B Med-Lo 3.S 1,402 63 1,380 64 1,343 66 1,319 67 1,296 69 1,24S 1,183 1,106 Low 3 1,200 --- 1,186 - 1,161 - 1,127 -- 1,082 - 1,042 995 926 High 5 2,469 42 2,389 43 2,300 45 2,223 47 2,131 49 2,027 1,902 1,786 GMH8 Med 4 1,57S 66 1,558 67 1,545 67 1,513 69 1,500 69 1,419 1,354 1,271 1405D*C Med-Lo 35 1,402 -- 1,380 - 1,343 -- 1,319 --- 1,296 - 1,24S 1,183 1,106 Low 3 1,200 1,186 - 1,161 1,127 - 1,082 ---- 1,042 995 926 @ 0.5"ESP NOTES • CFM in chart is without filter(s).Filters do not ship with this furnace,but must be provided by the installer.If the furnace requires two return filters,this chart assumes both filters are installed. • All furnaces ship as high-speed cooling and medium-speed heating.Installer must adjust blower cooling and heating speed as needed. • For most jobs,400 CFM per ton for cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • This chart is for information only. Forsatisfactory operation,external static pressure should not exceed value shown on the rating plate. • The dashed(-)areas indicate a temperature rise not recommended forthis model. • At higher altitudes,a properly derated unit will have approximately the same temperature rise at a particular CFM,while ESP at the CFM will be lower. SS-GMH8 www.goodmanmfg.com 7 GDH8 AIRFLOW DATA (CFM&TEMPERATURE RISE VS.EXTERNAL STATIC PRESSURE) MODEL MOTOR TONS EX=ESSURE,(INCHES WATER COLUMN) High 3.0 1,353 - 1,290 - 1,246 -- 1,199 2S 1,149 26 1,116 1,116 F96 GDH8 Med 2.5 1,183 25 1,113 27 1,098 27 1,OS2 28 1,039 29 1,006 1,012 0403A*B (Med)2 Med-Lo 2.0 980 30 946 31 920 32 900 33 896 33 885 855 804 Low 1.S 778 38 762 39 738 40 746 40 738 40 717 696 1 678 High 3.0 1,290 34 1,236 36 1,194 37 1,166 38 1,176 38 1,166 1,108 1,029 GDH8 Med 2.S 1,139 39 1,090 41 1,035 43 1,063 42 1,063 42 1020 962 89S 0603A*B (Med)2 Med-Lo 2.0 962 46 927 48 925 48 941 47 909 49 877 834 779 Low 1.5 787 S6 776 57 763 58 744 60 1 723 - 690 641 581 High 4.0 2,128 - 2,063 -- 2,001 -- 1,927 -- 1,824 -- 1,726 1,628 1,529 GDH8 Med 3.5 1,840 - 1,788 - 1,74S -- 1,689 35 1,625 36 1,550 1,470 1,364 0804E*B (Med)2 Med-Lo 3.0 1,602 37 1,558 38 1,543 38 1,493 40 1,455 41 1,402 1,328 1,239 Low 2.5 1,277 46 1,252 47 1,244 48 1 1,229 48 1 1,214 49 1,179 1141 1079 High 5.0 2,40S --- 2,361 -- 2,250 -- 2,161 - 2,037 36 1,937 1,808 1,689 GDH8 Med 4.0 1,880 39 1,838 40 1,794 41 1,734 43 1,677 44 1,568 1,510 1,401 1005C*B (Med)2 Med-Lo 3.5 16S9 45 1,630 4S 1,S87 47 1,537 48 1,492 50 1,445 1,368 1,287 Low 3.0 1,472 50 1,454 51 1,404 53 1,366 54 1,326 56 1300 1228 1139 Heating speed as shipped 2 @ 0.5"ESP Nc rFs • CFM in chart is without filter(s).Filters do not ship with this furnace,but must be provided by the installer.If the furnace requires two return filters,this chart assumes both filters are installed. • All furnaces ship as high-speed cooling and medium-speed heating.Installer must adjust blower cooling and heating speed as needed. • For mostjobs,400 CFM perton for cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • This chart is for information only. For satisfactory operation,external static pressure should not exceed value shown on the rating plate. • The dashed(-)areas indicate a temperature rise not recommended for this model. • At higher altitudes,a properly derated unit will have approximately the same temperature rise at a particular CFM,while ESP at the CFM will be lower. 8 www.goodmanmfg.com SS-GMH8 7 t,,4PERATURE RISE RANGE CHART O rr LO r v - O x � - W LL O U x 0 - (M O LL o - u � `i - G[ II O x O L - LL � m U = O O N L _ V'- � II M y _ ca K _ �. - Q _ O x - r u - W LLL - -_ 1Y V O O cc:) _ O o F - o N _ X W O N = d - O o W <D m � O � 0 - H O V\ \1 C) O GO `d O r Q t - O N N O - O 0 ~ co _ O r _ LL U - O o - co 0 - co - - O U) O n 11 t6LO (M O a) GOO O� (00 LO M N TO 3SIa 3dniv213dW31 SS-GMH8 www.goodmanmfg.com 9 WIRING DIAGRAM WARNING:DISCONNECT POWER BEFORE I--------�1eUylppp -1 INTEGRATED SERVICING WIRING TO UNIT MUST BE I ---- CONTROL MODULE PROPERLY POLARIZED AND GROUNDED I 1"MR b) GND I 24 VAC HUMIDIFIER I MVC 1%FF I MVH(1T1 M vntV I MVL fA I I ID BLOWER AUXILIARY I J PRESSURE C G R W V �� UMR CONTROLb bWITCH A1fT0 AD MN tl t; y�' PS(1o) G .�D 1 U9ECOO REL MMOD[ _'O P5014) JHUM AUTO RV lO 3 �'^Y ji I FUSE AUTO RESET J SEE NO Ee OR AUXILIARY � (RO2111) CONTROL LIMBS n I �ROf I5) W L PREGRATE0 L CONTROLNDDULE ; MANUAL RESET ROLLOUT G LNIT CONTROLS) a a TS (SINGLE CONTROL ON SOME MODELS) C c,�P fJ1 VAC G 40 VA F T BL RR TRANSFORMERF j?RD %F.— 115 VAC %FMR-N je 3 N C FLAME SENSOR j N t I HOi aiiR�A^F $ G S �nA+ [ I �ITJ•Lp LIGN-N C N t A a INTO IND-N O 2 m O I u n SK N 9 O coOLr r CIRCULATOR S W T OR BK 15 PIN PLUG y„ AIR CLE INEJ'% I CL W ON SOME MODELS L m � -_-_-_------ ----------- BLOWER COMPARTMENT- UNE-H L NE-N a+1y BURNER COMPARTMENT JUNCTON BOX C C 1 Odt SWITCH 24VAC DOR O W SNITCH LOCADOIN BLOWER HUMIDKTER SVVRCO H ^T1 /T' G COMPARTMENTON SOME MODELS W R \ ! WARNING: DISCONNECT PO'h'E Y S PRHIARY LIMB Yl SWITCH YL BEFORE SERVICINu. ) DISCONNECT ; WRING TO UNIT YL MUST BE I I I c n PROPERLY I I =o POLARIZED AND GROUNDED. 0R G D JUNCT ONN N I V eL OVERCURRENT PROTECTION DEVICE �► v•< K PM C HI C HOT T 2 3 BO% SURFACE 2 STAGE IGNITER GAS VALVE LtE - LINE-N (HONEY WELL) o- -- GND PU - LINE H 4 INDUCED DRAFT BLOWER TO 115VAC11-- PB PU FLAME POWER bUPPLV WITH SENSOR OVERCURRENTPROTECTION OLIOUT I.. DEVICE ?N e0 (SINGLE CONTROL OM SONS MODELS) 3 N C o STEADY ON=NORMAL OPERATION a o 3 OFF =CONTROL FAILURE LOW VOLTAGE(24V) EQUIPMENT GND rJ-j m E m 1 FLASH = SYSTEM LOCKOUT(RETRIES/RECYCLES EXCEEDED) LOW VOLTAGE FIELD --- } L o FIELD GND vA.2 FLASHES=PRESSURE SNITCH STUCK CLOSED HI VOLTAGE(115V) 1 3 FLASHES=PRESSURE SWITCH STUCK OPEN FIELD SPLICE v w a�a. J HI VOLTAGE FIELD --- a 4 FLASHES=OPEN HIGH LIMIT JUNCTION SWITCH(TEMP.) o--�a ; E z 5 FLASHES=FLAME SENSE WITHOUT GAS VALVE IGNITER S E a 6 FLASHES=OPEN ROLLOUT OR OPEN FUSE TERMINAL � _�� o J 7 FLASHES=LOW FLAME SIGNAL INTERNAL TO SWITCH(PRESS) "O- A B FLASHES=CHECK IGNITER OR IMPROPER GROUND INTEGRATED CONTROL OVERCURRENT c RAPID FLASHES=REVERSED 115 VAC POLARITYNERIFY GND PLUG CONNECTION PROT.DEVICE Ea NOTES: COLOR CODES: PK PINK 1.SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. YL YELLOW BR BROWN 2'MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. 3.IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE OR ORANGE WH WHITE REPLACED.IT MUST BE REPLACED WITH WIRING MATERIAL HAVING ATEMPERATURE PU PURPLE BL BLUE RATING OF AT LEAST WS C.USE COPPER CONDUCTORS ONLY. GR GREEN GY GRAY 4.BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION BK BLACK RD RED REOUIEMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM.(SEE SPEC SHEET FOR AIR FLOWCHART) 5.UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C.AND LOCAL CODES. 0140F00662 REV.A 6 F RRECALL MO E THAN 2 SECONDS THE LAST 5FAULTWHILE INSTANDBY(NO THERMOSTAT INPUTS)S SWITCH 10 www.goodmanmfg.com SS-GMH8 ACCESSORIES MODEL LPM-06 LP Conversion Kit(Springs&Orifice)' V V V V HANG20 High-Altitude Natural Gas Kit(4SOO+ft) V V V V V V V V FTK04 Twinning Kit V V V V V V V V V MVK-01' Masonry Vent Kits V V V V V V V MVK-021 Masonry Vent Kits V V AFE18-60A Fossil Fuel Kit V V V V V V V V V ' Honeywell or White-Rodgers valves ' Upflow applications only MODELDESCRIPTION ,., 1.1 1814 ill 511,111, E LP Conversion Kit(Springs&Orifice)' V V High-Altitude Natural Gas Kit(4500+ft) V V V V Twinning Kit V V V V Fossil Fuel Kit V V V V Downflow Sub-base V V V V ' Honeywell or White-Rodgers valves GMH8 MINIMUM FILTER SIZES MODEL „ 05 . . Filter Size(in') (1)16.21 (Side)or (1)16 x 25(Side or Bottom) (1)16 x 25 (2)16 x 25(Side)or (2)16 x 25(Side)or (1)14 x 24(Bottom) (Side or Bottom) (1)20 x 25(Bottom) (1)24 X 24(Bottom) Note:Other size filters of equal or greater surface area may be used;filters may also be centrally located. Use 2-16 x 25 filters on side returns or 20 x 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. GDH8 MINIMUM FILTER SIZES (2)14 x 20 Filter Size(in') (2)10 x 20 or(1)14 x 25 Top Return p e (1)16 x 25 Top Return (1)200 14 x x 25 Top Return Note:Other size filters of equal or greater surface area may be used;filters may also be centrally located, SS-GMH8 www.goodmanmfg.com 11 NoTEs Goodman Manufacturing Company,L.P.,reserves the right to discontinue,or change at any time,specifications or designs without notice or without Incurring obligations.02015 Goodman Manufacturing Company,L.P. • Houston,Texas • Printed in the USA. 12 www.goodmanmfg.com SS-GMH8 Permit#: 1312 Permit Date: 01/31/17 Permit Type: RESIDENTIAL MECHANICAL Project Nam e Phelps Applicant Nam a CM Heating Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett,WA98201 Contact: Meredith Gilbert Phone: 425-259-0550 Em al: m credith@cm Irating.com Scope of Work: Replace gas furnace Valuation: 0.00 Square Feet: 0 Num ber of Stories: 0 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 02/01/2017 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel# Address L egal Description O wner Nam e Caner Phone Zoning 00901400001800 3 131 186TH PL NE PHELPS MATHEW 111 Single Fam iy A&CHERYL Residence-Detached Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# CM HEATING INC 4 25-259-0550 1500 INDUSTRY CONSTRUCTION Plum fing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 4 25-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751 W ST STE 200 CONTRACTOR Contractor CM HEATING INC 4 25-259-0550 1500 INDUSTRY CONSTRUCTION UBI 6 05890285 ST STE 200 CONTRACTOR Fees Fee D escription N otes A m cunt Forced Air Heat f ee per Btu $ 25.00 Mechanical Base P enn i Fee $ 25.00 Processing/Technology $25.00 Total $75.00 Attached Letters Date Letter D escription 02/01/2017 Building Perm t Paym acts Date Paid By D escription P aym ant Type A ccepted By A m cunt 02/01/2017 DEBORAH BAUERS 6 3334367 c c $75.00 O ttstanding Balance $0.00 Uploaded Files Date File Nam e 02/01/2017 2078700-1312 Issued Perm t.pdf 02/01/2017 2078456-1312 Em al-Like-for-Like Change Out.pdf 02/01/2017 2078452-1312 Application.pdf 02/01/2017 2078453-1312 Specs.pdf