Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18924 46th Ave Ne_BLD3973_2026
CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT Permit#: 3973 18924 46TH AVE NE PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Parcel#: 00955700001700 Valuation: .00 OWNER APPLICANT CONTRACTOR WRIGHT BENJAMIN&NORMA CM Heating CM Heating Inc 18924 46TH AVE NE 1415 Broadway 1415 Broadway ARLINGTON,WA 98223-4792 Everett,WA 98201 Everett, WA 98201 4252590550 425-259-0550 LIC:CM IEAI*095R4 EXP:05/04/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR CM Heating Inc 1415 Broadway Everett,WA 98201 425-259-0550 LIC#: CMHEAI*095R4 EXP: 05/04/2023 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law, or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. TBCI]0/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. I'�4C&xItl)4 Wntl)cwy Kailana Moniz 06/21/21 �°fZ 6/21/2021 Signature Print Name Date U Releasd By Date CONDITIONS Adhere to approved appliance.Approved permit shall be onsite for inspections.Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 06/21/2021 Inspection Fee $75.00 06/21/2021 Forced Air Heat $15.00 06/21/2021 Mechanical Base $25.00 06/21/2021 Processing/Technology Fee $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon N. RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:18924 46TH AVE NE Project Description:GAS FURNACE REPLACEMENT A Owner: NORMA WRIGHT Address: 18924 46TH AVE NE City: ARLINGTON State WA Zip Code: 98223 Phone: 360-435-0974 Email:NORMALEEWRIGHT@OUTLOOK.COM Applicant: CM HEATING INC Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 Phone: 4252590550 Email: KAILANA@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:CM HEATING INC Address: 1415 BROADWAY City: EVERETT StateWA Zip Code: 98201 License Number: Expiration. Expiration. 05/2023 Phone:4252590550 Email:KAILANA@CMHEATING.COM I' STAFF USE ONLY + Received Permit #: �j(/D' j 1 Accepted by: DateJUN 17 202) 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #S8X2B080M4PSBA AFUE80 Heat Pump Model # - AFUE HSPE AC Unit Model # SEER - i❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ! Solid-Fuel Appliance Other - - I Gas Piping Information Not Applicable: [ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: p""r`nfl Date, 06/16/2021 Applicant Printed Name: KAILANA MONIz I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 C M HEATING INC Owner or tradesperson 1415 BROADWAY Principals EVERETT,WA 98201 GARNER,JAMES NICHOLAS,PRESIDENT 425-259-0550 SNOHOMISH County GIACOMI,JOHN A,DIRECTOR GARNER,JAMES NICHOLAS,AGENT SMITH,PAMELA (End:01/01/1980) GARNER,KATHLEEN DIANE,SECRETARY (End:06/04/2021) GARNER,PAUL MILTON,PRESIDENT (End: 10/01/2012) Doing business as C M HEATING INC WA UBI No Business type 601 114 652 Corporation Governing persons JAMES GARNER PAUL M GARNER; KATHLEEN GARNER; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. CMHEAI"095R4 Effective—expiration 12124/1991—05/04/2023 Bond CBIC $12,000.00 Bond account no. 655840 Received by L&I Effective date 04/24/2002 12/01/2001 Expiration date Until Canceled Insurance American Hallmark Ins Co of Te $1,000.000.00 Policy no. 44CL603347 Received by L&I Effective date 04122/2021 05/0312020 Expiration date 05/03/2022 Insurance history Savings No savings accounts during the previous L_ .r period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent No active Washington registered apprentices exist for this business.Washington allows the use of apprentices registered with Oregon or Montana.Contact the Oregon Bureau of Labor&Industries or Montana Department of Labor &Industry to verify if this business has apprentices. Workers' Comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 490,794-01 Doing business as CHIMNEY MASTERS Estimated workers reported Quarter 1 of Year 2021"51 to 75 Workers" L&I acuuunl uunlaul T3/NICHOLE CAROW(360)902-5634-Email:CANI235@lni.wa.gov Public Works Requirements Verify the contractor is eligible to perform work on public works projects Required Training—Effective July 1,2019 Needs to complete training. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace Safety & Health Check for any past safety and health violations found on jobsites this business was responsible for. No inspections during the previous 6 year period. Submittal Upflow / Downflow / Horizontal Left/Right Two Stage Non-condensing Gas Fired Furnace 80,000 BTU H S8X2B080M4PSBA Note:Models may have a "T"in the 12th digit designating they meet California less than 40 ng/J(NOx)emissions requirements. Note:Graphics in this document are for representation only.Actual model may differ in appearance. November 2020 S8X2B080M4-SUB-2B-EN ,-� - 3� 73 Outline Drawing Table 1. 17.5"Width Cabinet a "�- F- 3 o ,--r TT—L Lz� .a 3 = - i ' 10 a It III" 4 3 - - 00010E f s-¢r e 2 S8X2B080M4-SUB-2 B-E N Product Specifications MODEL S8X2B080M4PSBA(a) MODEL S8X2B080M4PSBA(a) Upflow/Horizontal/ TYPE Downflow Inducer Orifice 1.75 RATINGS(b) FILTER—Furnished? No 1st Stage Input BTUH 52,000 Type recommended High Velocity 1st Stage Capacity BTUH(ICS) 42,300 High Vel.(No.-Size-Thk.) 1-16 X 25-1 in. 2nd Stage Input BTUH 80,000 VENT PIPE DIAMETER—Min(in.)(e) 4 Round 2nd Stage Capacity BTUH(ICS)(c) 64,700 HEAT EXCHANGER-Type Aluminized Steel 1st Stage Temp.Rise(Min.-Max.)°F 30—60 Gauge(Fired) 20-19 2nd Stage Temp.Rise(Min.-Max.)°F 30—60 ORIFICES—Main AFUE(%)(c) 80 Nat.Gas Qty.—Drill Size 4-45 Return Air Temp.(Min.-Max.)°F 55°F-80°F L.P.Gas Qty.-Drill Size 4-56 GAS VALVE Redundant-Two Stage BLOWER DRIVE DIRECT Diameter—Width(In.) 11 X 8 PILOT SAFETY DEVICE-Type 120 V SiNi Igniter No.Used 1 BURNERS—(QTY) 4 Speeds(No.)(d) CTM-9 POWER CONN.—V/Ph/Hz M 120/1/60 Ampacity(Amps) 12.0 CFM vs,in.w. 9• See Fan Performance Table Max.Overcurrent Protection(Amps) 15 Motor HP 3/4 PIPE CONN.SIZE(in.) 1/2 RPM 1050 (e) Central Furnace heating designs are certified to ANSI Z21.47-latest Volts/Ph/Hz 120/1/60 edition. (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 FLA 9.2 feet,derate 4%per 1,0000 feet for elevations above 2,000 feet above sea level. COMBUSTION FAN—Type PSC (0 Based on U.S.government standard tests. (d) 9 Speed constant torque ECM Blower Motor. Drive—No.Speeds Direct-2 (e) Refer to the Installer's Guide. Motor RPM 3200/2400 M The above wiring specifications are in accordance with National Volts/Ph/Hz 120/1/60 Electric Code,however,installations must comply with local codes. FLA 0.29 S8X2B080M4-SUB-2B-EN 3 Airflow Table Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 O.S 0.7 0.9 1 633 297 — — — 2 957 800 719 428 213 3 1220 1080 940 B00 660 4 1403 1298 1192 1087 981 SBX2BOBOM4PSBA 5 1524 1428 1336 1248 1164 6 1684 1574 1544 1401 1337 7 1700 1625 1551 1476 1401 8 1858 1790 1723 1656 1589 9 1967 1898 1829 1760 1691 4 S8X213080M4-SUB-213-EN CFM Versus Temperature Rise Table 2. SM — Low Heat Model CFM Versus Temperature Rise—First Stage(Low)Heating 400 15001,600170018001 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 SBX2B080M4PSBA I 1 1 55 1 48 1 43 1 39 1 35 1 32 1 30 1 28 Table 3. S8X2 — High Heat Model CFM Versus Temperature Rise—Second Stage(High)Heating 400 500 600 700 800 900 110001110011200 1 1300 1400 1500 1600 1700 1800 1900 12000 121001 2200 2300 24o0 S8X213080WPSBA 59 1 54 1 49 1 46 1 42 1 40 1 37 1 35 1 33 SM26080W-SUB-213-EN 5 General Features NATURAL GAS MODELS valve,flame control and includes self diagnostics for Central Heating furnace designs are certified by Intertek ease of service. for both natural and L.P. gas. Limit setting and rating ENERGY EFFICIENT OPERATION data were established and approved under standard Air-TiteT11 cabinet design is certified to<1%air leakage rating conditions using American National Standards per ASHRAE 193 "Method of Test for Determining the Institute standards. Airtightness of HVAC Equipment." SAFE OPERATION AIR DELIVERY The Integrated System Control is a solid state device The 9 speed constant torque blower motor has which continuously monitors for presence of flame sufficient airflow for most heating and cooling when the system is in the heating mode of operation. requirements and will switch from heating to cooling Dual solenoid combination gas valve and regulator speeds on demand from room thermostat. provide additional safety. STYLING QUICK HEATING Heavy gauge steel and "wrap-around"cabinet Durable,cycle tested, Leavy gauge tubular aluminized construction is used in the cabinet with baked-on steel heat exchanger quickly transfers heat to provide enamel finish for strength and beauty. Every warm conditioned air to the structure. Low energy orientation has at least two venting options.There are power vent blower,to increase efficiency and provide no knockouts on cabinet. a discharge of gas fumes to the outside. FEATURES AND GENERAL OPERATION BURNERS The S-Series furnace utilizes a Silicon Nitride Hot Multiport,Inshot burners will give years of quiet and Surface Ignition system,which eliminates the waste of efficient service.All models can be converted to L.P. a constant burning pilot.The integrated system control gas with LP conversion kit. lights the main burners upon a demand for heat from INTEGRATED SYSTEM CONTROL the room thermostat.Complete front service access. Exclusively designed operational program provides a. Low energy power venter total control of furnace limit sensors, blowers,gas b.Vent proving pressure switches. 6 S8X2B080M4-SUB-2B-EN Features and Benefits 80%AFUE on S8X2 FURNACE MODELS Cabinet is compatible with industry standard coils,as Lowers utility bills well as,other accessories ELECTRICALLY EFFICIENT INTEGRATED FURNACE CONTROL Efficient airflow design reduces electrical energy use Setup/Status/Diagnostics/Digital Display 34 INCH TALL No dip switches Lighter,easier to move and fit into tight spaces like Last six errors stored short basements or tight closets Dry contact EAC and HUM connections Works great with larger,high-efficiency coils All Molex connections;no spade terminals No knockouts Low voltage labeled above and below 4—WAY MULTI-POISE Rain shield over IFC keeps condensate off the control 7 SKU's — Upflow/Downflow/Horizontal Left/ TUBULAR ALUMINIZED STEEL HEAT EXCHANGER Horizontal Right VORTICA II BLOWER, DESIGNED EXCLUSIVELY Added application flexibility and reduction in FOR THE S-SERIES FURNACE specification errors Improved airflow efficiency AIRFLOW Durable,easy to clean,housing At least 400 CFM/ton at 0.5 in. H2O external static Single piece belly band/motor arm assembly pressure REGULATORY Blower deck has full-length rails for easy removal and replacement,regardless of poise All models are air tight; 1%or less air leakage as per FOUR—WAY MULTI-POISE(UPFLOW,DOWNFLOW, ASHRAE 193 HORIZONTAL LEFT AND RIGHT) Open vestibule design provides a full 34" high open Easier to specify vestibule for ease of installation and service DIMENSIONS Shipped ready to install (no conversion kits required) Width is industry standard: 17.5" Every model has at least two venting options Depth remains approximately 28" S8X2 B080M4-SUB-2 B-E N 7 About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable,energy efficient indoor environments for residential applications. For more information,please visit www.trane.com or www.americanstandardair.com. O�jus Intertek The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. SSX2B080M4-SUB-2B-EN 20 Nov 2020 Supersedes S8X2B080M4-SUB-2A-EN (October 2020) 02020 CITY OF ARLINGTON Dw 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 —BUILDING PERMIT Permit#:3973 18924 46TH AVE NE PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Parcel#: 00955700001700 Valuation: .00 OWNER APPLICANT CONTRACTOR WRIGHT BENJAMIN&NORMA CM Heating CM Heating Inc 18924 46TH AVE NE 1415 Broadway 1415 Broadway ARLINGTON,WA 98223-4792 Everett,WA 98201 Everett,WA 98201 4252590550 425-259-0550 LIC:CMHEAI*095R4 EXP:05/04/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR CM Heating Inc 1415 Broadway Everett,WA 98201 425-259-0550 LIC#: CMHEAI*095R4 EXP: 05/04/2023 LIC#: EXP: JOB DESCRIPTION FEW PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: - `PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. rLv� 6/21/2021 Signature Print Name Date Rcicas By Date -CONDITION - Adhere to approved appliance.Approved permit shall be onsite for inspections.Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. ' PERMIT FEES - Date Description Fee Amount 06/21/2021 Inspection Fee $75.00 06/21/2021 Forced Air Heat $15.00 06/21/2021 Mechanical Base $25.00 06/21/2021 Processing/Technology Fee $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 3973 Permit Date: 06/21/21 Permit Type: RESIDENTIAL MECHANICAL Project Name: Wright Applicant Name: CM Heating Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett,WA 98201 Contact: Kailana Moniz Phone: 4252590550 Email: kailana@cmheating.com Scope of Work: Gas furnace change out Like for like Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 06/22/2021 Permit Expires: 12/22/2021 Form Permit Type: Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning WRIGHT 100 SINGLE 00955700001700 18924 46TH AVE NE BENJAMIN& FAMILY NORMA RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Plumbing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751W ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION UBI 605890285 ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C10. 06/22/2021 MECHANICAL 06/23/2021 06/23/2021 BUILDING Completed ROUGH-IN Fees Fee Description Notes Amount Inspection $75.00 Forced Air Heat fee per Btu $15.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Credit Card Service $4.20 Total $144.20 Attached Letters Date Letter Description 06/21/2021 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 06/21/2021 JOHN GIACOMI 87148774 $140.00 06/21/2021 87148774 Ameresia Lawlis $4.20 Outstanding Balance $0.00 Uploaded Files Date File Name 06/22/2021 9077322-NORMA WRIGHT SIGNED MECH PERMIT.pdf 06/21/2021 9067555-Wright S8X2B080M4-SUB-2B-EN.pdf 06/21/2021 9067556-Wright Residential Mechanical 1NFFavhDUO1JC0.pdf CITY OF ARLINGTON ` 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT Permit#:3973 18924 46TH AVE NE PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Parcel#: 00955700001700 Valuation: .00 OWNEIR APPLICANT CONTRACTOR WRIGHT BENJAMIN&NORMA CM Heating CM Heating Inc 18924 46TH AVE NE 1415 Broadway 1415 Broadway ARLINGTON,WA 98223-4792 Everett,WA 98201 Everett,WA 98201 4252590550 425-259-0550 LIC:CMIIEAI*095R4 EXP:05/04/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR CM Heating Inc 1415 Broadway Everett,WA 98201 425-259-0550 LIC#: CMHEAI*095R4 EXP: 05/04/2023 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington 93101. ?! o'� Kailana Moniz 06/21/21 6/21/2021 Signature ellPrint Name Date Releas&d By Date CONDITIONS _ Adhere to approved appliance.Approved permit shall be onsite for inspections.Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 06/21/2021 Inspection Fee $75.00 06/21/2021 Forced Air Heat $15.00 06/21/2021 Mechanical Base $25.00 06/21/2021 Processing/Technology Fee $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon �_y Q. RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address- 18924 46TH AVE N E Project Description:GAS FURNACE REPLACEMENT Owner: NORMA WRIGHT Address: 18924 46TH AVE NE City: ARLINGTON State WA Zip Code: 98223 Phone: 360-435-0974 Email:N0RMALEEWRIGHT@0UTLO0K.00M Applicant: CM HEATING INC Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 Phone: 4252590550 Email: KAILANA@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:CM HEATING INC Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration. 05/2023 Phone. 4252590550 Email:KAI LANA@ C M H EATI N G.0 OM STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #S8X2B080M4PSBA AFUE80 ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: tl5a51c3bba4a9294ftlaeB�e Date: 06/16/2021 Applicant Printed Name: KAILANA MONIZ I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 Submittal Upflow / Downflow / Horizontal Left/Right Two Stage Non-condensing Gas Fired Furnace 80,000 BTU H S8X2B080M4PSBA e u•� Note:Models may have a "T"in the 12th digit designating they meet California less than 40 ng/J(NOx)emissions requirements. Note:Graphics in this document are for representation only.Actual model may differ in appearance. November 2020 S8X2 B080M4-SUB-2 B-E N Outline Drawing Table 1. 17.5"Width Cabinet m= z= F7 I I I I I I - I I I I I — ----- I=-- 00000v T TF-` LT L-7-!-L�L2 19 _ m - � 000000 I I I I s " a o 2 S8X2B080M4-SUB-2B-EN Product Specifications MODEL S8X2B080M4PSBA(a) MODEL S8X2B080M4PSBA(a) TYPE Upflow/Horizontal/ Inducer Orifice 1.75 Downflow RATINGS(b) FILTER—Furnished? No 1st Stage Input BTUH 52,000 Type recommended High Velocity 1st Stage Capacity BTUH(ICS) 42,300 High Vel.(No.-Size-Thk.) 1-16 X 25-1 in. 2nd Stage Input BTUH 80,000 VENT PIPE DIAMETER—Min(in.)(e) 4 Round 2nd Stage Capacity BTUH(ICS)W 64,700 HEAT EXCHANGER-Type Aluminized Steel 1st Stage Temp.Rise(Min.-Max.)°F 30—60 Gauge(Fired) 20-19 2nd Stage Temp.Rise(Min.-Max.)°F 30—60 ORIFICES—Main AFUE(%)(c) 80 Nat.Gas Qty.—Drill Size 4-45 Return Air Temp.(Min.-Max.)°F 55°F-80°F L.P.Gas Qty.-Drill Size 4-56 GAS VALVE Redundant-Two Stage BLOWER DRIVE DIRECT Diameter—Width(In.) it X 8 PILOT SAFETY DEVICE-Type 120 V SiNi Igniter BURNERS—(QTY) 4 No.Used 1 Speeds(No.)(d) CTM-9 POWER CONN.—V/Ph/Hz(f) 120/1/60 CFM vs.in.w.g. See Fan Performance Table Ampacity(Amps) 12.0 Max.Overcurrent Protection(Amps) 15 Motor HP 3/4 PIPE CONN.SIZE(in.) 1/2 RPM 1050 (a) Central Furnace heating designs are certified to ANSI Z21.47-latest Volts/Ph/Hz 120/1/60 edition. (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 FLA 9.2 feet,derate 4%per 1,0000 feet for elevations above 2,000 feet above sea level. COMBUSTION FAN—Type PSC (c) Based on U.S.government standard tests. Drive—No.Speeds Direct-2 (d) 9 Speed constant torque ECM Blower Motor. (e) Refer to the Installer's Guide. Motor RPM 3200/2400 M The above wiring specifications are in accordance with National Electric Code,however,installations must comply with local codes. Volts/Ph/Hz 120/1/60 FLA 0.29 S8X2B080M4-SUB-2B-EN 3 Airflow Table Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 633 297 — — — 2 957 800 719 428 213 3 1220 1080 940 800 660 4 1403 1298 1192 1087 981 S8X2BO8OM4PSBA 5 1524 1428 1336 1248 1164 6 1684 1574 1544 1401 1337 7 1700 1625 1551 1476 1401 8 1858 1790 1723 1656 1589 9 1967 1898 1829 1760 1691 4 S8X2B080M4-SUB-2B-EN CFM Versus Temperature Rise Table 2. SM — Low Heat CFM Versus Temperature Rise—First Stage(Low)Heating Model 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 S8X2BO8OM4PSBA 1 1 55 48 1 43 1 39 1 35 1 32 1 30 1 28 Table 3. S8X2 — High Heat CFM Versus Temperature Rise—Second Stage(High)Heating Model 400 500 600 700 800 900 1000 1100 1200 1 1300 1400 1500 1600 1700 1800 1900 1 2000 2100 2200 2300 2400 S8X2BO8OM4PSBA 59 1 54 1 49 1 46 1 42 1 40 1 37 1 35 1 33 S8X2BO8OM4-SUB-2B-EN 5 General Features NATURAL GAS MODELS valve,flame control and includes self diagnostics for Central Heating furnace designs are certified by Intertek ease of service. for both natural and L.P.gas. Limit setting and rating ENERGY EFFICIENT OPERATION data were established and approved under standard Air-TiteT°^ cabinet design is certified to<1%air leakage rating conditions using American National Standards per ASHRAE 193"Method of Test for Determining the Institute standards. Airtightness of HVAC Equipment." SAFE OPERATION AIR DELIVERY The Integrated System Control is a solid state device The 9 speed constant torque blower motor has which continuously monitors for presence of flame sufficient airflow for most heating and cooling when the system is in the heating mode of operation. requirements and will switch from heating to cooling Dual solenoid combination gas valve and regulator speeds on demand from room thermostat. provide additional safety. STYLING QUICK HEATING Heavy gauge steel and "wrap-around"cabinet Durable,cycle tested, heavy gauge tubular aluminized construction is used in the cabinet with baked-on steel heat exchanger quickly transfers heat to provide enamel finish for strength and beauty. Every warm conditioned air to the structure. Low energy orientation has at least two venting options.There are power vent blower,to increase efficiency and provide no knockouts on cabinet. a discharge of gas fumes to the outside. FEATURES AND GENERAL OPERATION BURNERS The S-Series furnace utilizes a Silicon Nitride Hot Multiport, Inshot burners will give years of quiet and Surface Ignition system,which eliminates the waste of efficient service.All models can be converted to L.P. a constant burning pilot.The integrated system control gas with LP conversion kit. lights the main burners upon a demand for heat from INTEGRATED SYSTEM CONTROL the room thermostat. Complete front service access. Exclusively designed operational program provides a. Low energy power venter total control of furnace limit sensors,blowers,gas b.Vent proving pressure switches. 6 S8X2B080W-SUB-213-EN Features and Benefits 80%AFUE on S8X2 FURNACE MODELS Cabinet is compatible with industry standard coils,as Lowers utility bills well as,other accessories ELECTRICALLY EFFICIENT INTEGRATED FURNACE CONTROL Efficient airflow design reduces electrical energy use Setup/Status/Diagnostics/Digital Display 34INCH TALL No dip switches Lighter,easier to move and fit into tight spaces like Last six errors stored short basements or tight closets Dry contact EAC and HUM connections Works great with larger, high-efficiency coils All Molex connections; no spade terminals No knockouts Low voltage labeled above and below 4—WAY MULTI-POISE Rain shield over IFC keeps condensate off the control 7 SKU's — Upflow/Downflow/Horizontal Left/ TUBULAR ALUMINIZED STEEL HEAT EXCHANGER Horizontal Right VORTICA II BLOWER,DESIGNED EXCLUSIVELY Added application flexibility and reduction in FOR THE S-SERIES FURNACE specification errors Improved airflow efficiency AIRFLOW Durable,easy to clean, housing At least 400 CFM/ton at 0.5 in. H2O external static Single piece belly band/motor arm assembly pressure REGULATORY Blower deck has full-length rails for easy removal and replacement,regardless of poise All models are airtight; 1%or less air leakage as per FOUR—WAY MULTI-POISE (UPFLOW, DOWNFLOW, ASHRAE 193 HORIZONTAL LEFT AND RIGHT) Open vestibule design provides a full 34" high open Easier to specify vestibule for ease of installation and service DIMENSIONS Shipped ready to install (no conversion kits required) Width is industry standard: 17.5" Every model has at least two venting options Depth remains approximately 28" S8X2BO80M4-SUB-2B-EN 7 About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable,energy efficient indoor environments for residential applications. For more information,please visit www.trane.com or www.americanstandardair.com. M"Admklt, 0%. -s Intertek The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. S8X2B080M4-SUB-2B-EN 20 NOV 2020 Supersedes S8X2BO8OM4-SUB-2A-EN (October 2020) ©2020