Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
19413 45th Dr Ne_BLD3864_2026
CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS'360-403_3417-Permit Center:360-403-3551 BUILDING PERMIT 19413 45�TD, NE Permit#:3864 Parcel#l: 00928200007400 PERMIT EXPIRES 180 DAYS AFTER OWNER DATE OF ISSUANCE. AYNOR GORDON&ANGGLA APPLICANT Valuation: .00 eating 19413 45TH DR NE CM if CONTRACTOR ARLINGTON, WA 98223-4758 1415 Broadway CM Heating Inc Everett. WA 98201 1415 Broadway 425-259-0550 Everett,WA 98201 MECHANICAL CONTRACTOR425-259-0550 CM Heating Inc LIC:CMHEAI*095R4 EXP:05/04/2023 1415 Broadway PL UMgiNG CONTRACTOR Everett, WA 98201 425-259-0550 LIC#: CMHEAI*095R4 EXP: 05/04/2023 LIC #: PF,RMIT'TYPE; JOB DESCRip EXP: Residential Mechanical TjON S TORIES: DWELLING UNITS; CODE YEAR: 2018 BUILDINGS: CGNST- TYPE: OCC GROUP: The issuance or granting of this a PERMIT gppCC LOgp p rmit shall not be construed to be ROYAL` other ordinance or order of the City,of an state Governor of this State. To the extent the issu issuance a eral granting a Pew it for,or approval of,any violation of this Code or any or s anY order, proclamation,guidance advice or decision of the Period of time when such construction is prohibited or restricted b y aadvice or decision of the Governor of this State,this g of this pew�t is interpreted to allow construction activity during any ur Official is authorized a prevent occupancy or use of a structure Where ny State or federal law,or order,proclamation,guidance jurisdiction or an Permit shall not authorize such work and shall not be valid.The building guidance advice or decision ordin nee or executive r. order�di the Ct �n Violation of this Code,any other City ordinances of this deter►nined to be issued in error or on the basis of incorrect, inaccurate of any State or federal law,or of any order,proclamation, ordinance,regulation or order,state or federal law,or incorrect, t d etal is authorized to suspend a revoke this permit o it n rate or incomplete information,or in violation of any City I AGREE TO COMPLY WITH CI y order,prOClamatton, guidance or decision of the Governor. AUTHORIZED THERE NO PERSON OF WASH�GTON RELATING�AND STATE LAWS RF,GULA1- WILL BE EMPLOYED ilV V G CONSTRUCTION AND IN DOING THE WORK THIS APPLICATION IS NOT A PERMIT UNTIL COMPENSATIONIDEATION OF THE LABOR CODE OF THE STATE ALL FEES ARE PAID. UNTIL SIGNED BY THE $ "4SURANCE AND RCW 18.27. UIL-DrNG OFFICIAL OR HIS/HER DEPUTY AND IT[S UNLAWFUL TO USE OR OCCUPY MADF.AND APPROVAL OR A CERTIFICATE OF CCU OCCUPANCY SALFS T TUIZE UNTIL A FINAL INSPECTION HAS BEEN AX NOTiC Sales tax relating to construction and construHA S B EEN GR ANTED. IBC I I0/IRC 110. Your sales tax return form and coded City of Arlington#3101. ctip� TIMI aterials in the City of Arlington must be reported on Signature Kailana Moniz 05/04/ Print Name 7 Date 05/04/2021 _!raked By Date use of adhesive tapes are CONDITIONS inspection. shall be onsite for inspections.Call for final bracing attached.Provide electrica disconnect.Lines shall be t'o TO BE DONE ON PRIVATE 3 concrete pad with seismic .Approved job copy RK prohibited.Adhere to approved applianceTHIS PERMIT COVERS WOIDEWALKS,DRIVEWAYS, T1IIS PERMIT AUTHORIZES ONLY THE WORK NOTED. P Y. ANY CONS'I'RUC I'IUN ON L REQUIRE SEPARATE PERMS SION. ROPER'lY ONLY. MARQUEES,ETC.)WiL PERMIT FEES Fee Amount $75.00 $25.00 Date Description $15.00 05/04/2021 Inspection Fee $25.00 05/04/2021 Air Cond.Unit $4.20 05/04/2021 Mechanical Base $144 20 05104/2021 processin9Rechnology Fee Total Due: 05/04/2021 Credit Card Surcharge $144.20 Total Payment: $0.00 Balance Due' CALL FOR INSPECTIONS inspections m for next day inspection,allow 48 hours for information. or afternoon Call by 3:30 p ection please Icave the following When calling for an insp you refer morning per mit Number,Type of Inspection being requested,and whether y P Permit#: 3864 Permit Date: 05/04/21 Project Name: Gaynor Company/Applicant Name: CM Heating Company/Applicant Address: 1415 Broadway City, State, Zip: Everett, WA 98201 Contact: Kailana Phone: 425-259-0550 Email: Kailana@cmheating.com Permit Type: Residential Mechanical Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Type of Construction: Occupancy Type: Scope of Work: Ac installation MIC/Opportunity Zone: Permit Issued: Permit Expires: 10/31/2021 DNU: Status: IN PROCESS Assigned To: Jennifer Pittman Property Parcel# Address Legal Description Owner Name Owner Phone Zoning GAYNOR 100 SINGLE 00928200007400 19413 45TH DR NE GORDON& FAMILY ANGELA RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM Heating Inc 425-259-0550 1415 Broadway CONTRACTOR Labor& CMHEAI*095R4 Industries Fees Fee Description Notes Amount Inspection Fee $75.00 Air Cond.Unit Btu/h< 100>; $25.00 Btu/hp>500 Mechanical Base Permit Fee $15.00 Processing/Technology Fee $25.00 Total $140.00 Uploaded Files Date File Name 05/04/2021 8736771-38(-4 Specs.pdf OS/04/2021 8736772-3864 App(ication.pdf RESIDENTIAL MECHANICAL • A PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address;19413 45TH DR N E Project Description:AC INSTALLATION Owner: GORDON GAYNOR Address: 19413 45TH DR NE City: ARLINGTON State WA Zip Code: 98223 Phone: 3606584981 Email:gaab67@ comcast.net Applicant: KAILANA MONIZ- CM HEATING 1415 BROADWAY EVERETT Address: . City: StatewA Zip Code: 98201 Phone: 4252590550 Email: KAILANA@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:CM HEATING INC Address: 1415 BROADWAY City: EVERETT StateYVA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration: 05/03/21 Phone:4252590550 Email:KAILANA@ C M H EATIN G.0 OM STAFF USE ONLY Received U Permit#: B LD- 4'3(p -( Accepted by: Date:APR 2 9 2021 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION IN Department of Community & Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223 • Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model# AFUE _ Heat Pump Model # AFUE HSPE [� AC Unit Model # 4A7A3024H1000N SEER ❑ Freestanding Stove U Fire Place Insert [A Outdoor BBO Gas Piping U Solid-Fuel Appliance Other Gas Piping Informatlon Not Applicable: Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances keY�JC�r�'ICyf Applicant Signature: Date: 04/29/2021 Applicant Printed Name: KAILANA MONIZ I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws'of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 Amerfew Shwdard.. HEATING & AIR CONDITIONING Submittal Split System Cooling 2.0 Ton 4A7A3024H1000N IIIIII IIII llllll. � �! III[10[[ 11111111111 � [I[[[IIII II llllllllllll IIIIII IIIII Illlffl[fll[II I llllllllll111111, I IIIIII IUII[Illf[ IIIII llllllllllllllll , [II II IIIIII flllf[UI[ III llllll1111111, [III IIIIII 111 � II[ III llllllllllllllll, � TAG: I Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. December2014 4A7A3024H-SUB-1A-EN LR�IngersollRand HEATING & AIR CONDITIONING SERVICE PANEL ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES I UP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524(5 FEET) ABUVL UIVI I.UNI I SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT AND SHOULD BE AT LEAST 305(12")FROM WALL AND ALL SURROUNDING SHRUBBERY ONTWO SIDES. OTHERTWO SIDES UNRESTRICTED ELECTRICAL SERVICE. K PANEL 25{7I 22,2(7/8)DIA.HOLE A LOW VOLTAGE 28.6(1-1/8)DIA.K.O.WITH 22.2(7/8)DIA.HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPLY LIOUIDLINESERVILEVALVE,— H „E.. C I.D.FEMALE BRAZE CONNECTION WITH WITH 1l4"SAE FLARE PRESSURETAP FITTINGS O FIG.1 K.O.rOR ALTERNATE ELECTRICAL ROUTING From Dwg.D152890 GAS LINE 1/4TURN BALL SERVICE VALVE, „D" I.D.FEMALE BRAZED CONNECTION WITH 1/4"SAE FLARE PRESSURE TAP FITTING.A Model Base A B C D E F G H ] K 4A7A3024H 2 730 724 651 3/4 3/8 137 65 210 57 457 (28-3/4) (28-1/2) (25-5/8) (5-3/8) (2-5/8) (8-1/4) (2-1/4) (18) SOUND POWER LEVEL Model A-Weighted Sound Full Octave Sound Power[dB] Power Level[dB(A)] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A7A3024H 74 47.9 60.5 64.1 71.2 71.2 _ 69.0 58.2 51.5 Note:Rated In accordance with AHRI Standard 270-2008 2 4A7A3024H-SUB-1 A-E N 79AW�Off sAWd HEATING & AIR CONDITIONING Product Specifications OUTDOOR UNIT(a)(b) 4A7A3024H1000N (a) Certified in accordance with the Air-Source Unitary Air-conditioner POWER CONNS.—V/PH/HZ(0 208/230/1/60 Equipment certification program,which is based on AHRI standard 210/240. MIN.BRCH.CIR.AMPACITY 18 (b) Rated in accordance with AHRI standard 270. BR.CIR.PROT.RTG.—MAX.(AMPS) 30 M Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. COMPRESSOR DURATION'"-SCROLL (a) This value shown for compressor RLA on the unit nameplate and on NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit ampacity and max,fuse size.The value shown is the branch circuit VOLTS/PH/HZ 208/230/1/60 selection current. R.L.AMPS(d)—L.R.AMPS 13.5—58.3 (a) No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter. FACTORY INSTALLED M Standard Air—Dry Coil—Outdoor (a) This value approximate.For more precise value see unit nameplate. START COMPONENTS(el NO (h) Max.linear length 60ft.;Max.lift—Suction 60ft.;Max.lift—Liquid INSULATION/SOUND BLANKET NO 60 ft.For greater length consult refrigerant piping software Pub.No. COMPRESSOR HEAT NO 32-3312-0*(*denotes latest revision). OUTDOOR FAN PROPELLER DIA.(IN.)—NO.USED 18.2—1 TYPE DRIVE—NO.SPEEDS DIRECT—1 CFM @ 0.0IN.W.G.M 2450 NO.MOTORS—HP 1-1/8 MOTOR SPEED R.P.M. 1075 VOLTS/PH/H Z 200/230/1/60 F.L.AMPS 0.90 OUTDOOR COIL—TYPE SPINE FIN'" ROWS—F.P.I. 1-24 FACE AREA(SQ.FT.) 12.89 TUBE SIZE(IN.) 3/8 REFRIGERANT LBS.—R-410A(O.D.UNIT)(9) 4 LBS.,11 OZ FACTORY SUPPLIED YES LINE SIZE—IN.O.D.GAS(h) 3/4 LINE SIZE—IN.O.D.LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10°F DIMENSIONS H X W X D CRATED(IN.) 30.1 x 26.7 x 30 WEIGHT SHIPPING(LBS.) 150 NET(LBS.) 130 4A7A3024H-SUB-1 A-EN 3 J (* Wff SAWdW r HEATING & AIR CONDITIONING Mechanical Specification Options General Compressor The Outdoor Units are fully ohargod from tho factory The comprecsor featurec internal over temperature, for up to 15 feet of piping.This unit is designed to pressure protection and total dipped hermetic motor. operate at outdoor ambient temperatures as high as Other features include:Centrifugal oil pump and low 11 YF.Cooling capacities are matched with a wide vibration and noise. selection of air handlers and furnace coils that are AHRI Condenser Coil certified.The unit is certified to UL 1995.Exterior is designed for outdoor application. The outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protected on all four Casing sides by louvered panels. Unit casing is constructed of heavy gauge,G60 Low Ambient Cooling galvanized steel and painted with a weather-resistant powder paint on all louvered panels and prepaint on all As manufactured,this system has a cooling capacity to other panels.Corrosion and weatherproof CMBP-G30 55°F.The addition of an evaporator defrost control base. permits operation to 401F.The addition of an evaporator defrost control with TXV permits low Refrigerant Controls ambient cooling to 30°F. Refrigeration system controls include condenser fan, Thermostats—Cooling only and heat/cooling(manual compressor contactor and high pressure switch.High and automatic change over).Sub-base to match and low pressure controls are inherent to the thermostat and locking thermostat cover. compressor.A factory supplied liquid line drier is standard.Some models may require field installation. Evaporator Defrost Control—See Low Ambient Cooling. AMRS CERTIFIED,. O(t� U Intertek Amai6" S*",dzw t,, HEATING & AIR CONDITIONING American Standard optimizes the performance of homes and buildings around the world.A business of Ingersoll Rand, the leader in creating and sustaining safe,comfortable and energy efficient environments,American Standard offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information,visit www.americanstandardair.com. American Standard has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2012 American Standard Heating&Air Conditioning 4A7A3024H-SUB-IA-EN 19 Dec 2014 4M0Ingersoll Rand Supersedes(New) �_y Q. RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 19413 45TH DR NE Project Description:AC INSTALLATION Owner: GORDON GAYNOR Address: 19413 45TH DR NE City: ARLINGTON State WA Zip Code: 98223 Phone: 3606584981 Email:gaab67@ comcast.net Applicant: KAILANA MONIZ- CM HEALING Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 Phone: 4252590550 Email: KAILANA@CMHEALING.COM CONTRACTOR INFORMATION Contractor Name:CM HEALING INC Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration. 05/03/21 Phone. 4252590550 Email:KAI LANA@ C M H EALI N G.0 OM STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) Model # AFUE ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # 4A7A3024H1000N SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: tl5a51c3bba4a9294ftlaeB�e Date: 04/29/2021 Applicant Printed Name: KAILANA MONIZ I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 CITY OF ARLINGTON ` 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT Permit#:3864 19413 45TH DR NE PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Parcel#: 00928200007400 Valuation: .00 OWNER APPLICANT CONTRACTOR GAYNOR GORDON&ANGELA CM Heating CM Heating Inc 19413 45TH DR NE 1415 Broadway 1415 Broadway ARLINGTON,WA 98223-4758 Everett,WA 98201 Everett,WA 98201 425-259-0550 425-259-0550 LIC:CMIIEAI*095R4 EXP:05/04/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR CM Heating Inc 1415 Broadway Everett,WA 98201 425-259-0550 LIC#: CMHEAI*095R4 EXP: 05/04/2023 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington 93101. N24 Kailana Moniz 05/04/21 05/04/2021 Signature Print Name Date leased By Date CONDITIONS 3"concrete pad with seismic bracing attached.Provide electrical disconnect.Lines shall be insulated;use of adhesive tapes are prohibited.Adhere to approved appliance.Approved job copy shall be onsite for inspections.Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 05/04/2021 Inspection Fee $75.00 05/04/2021 Air Cond. Unit $25.00 05/04/2021 Mechanical Base $15.00 05/04/2021 Processing/Technology Fee $25.00 05/04/2021 Credit Card Surcharge $4.20 Total Due: $144.20 Total Payment: $144.20 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON Dw 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT Permit#:3864 19413 45TH DR NE PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Parcel#: 00928200007400 Valuation: .00 OWNER APPLICANT CONTRACTOR GAYNOR GORDON&ANGELA CM Heating CM Heating Inc 19413 45TH DR NE 1415 Broadway 1415 Broadway ARLINGTON,WA 98223-4758 Everett,WA 98201 Everett,WA 98201 425-259-0550 425-259-0550 LIC:CMHEAI*095R4 EXP:05/04/2023 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR CM Heating Inc 1415 Broadway Everett,WA 98201 425-259-0550 LIC#: CMHEAI*095R4 EXP: 05/04/2023 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 05/04/2021 Signature Print Name Date Meased By Date CONDITIONS 3"concrete pad with seismic bracing attached.Provide electrical disconnect.Lines shall be insulated;use of adhesive tapes are prohibited.Adhere to approved appliance.Approved job copy shall be onsite for inspections.Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 05/04/2021 Inspection Fee $75.00 05/04/2021 Air Cond. Unit $25.00 05/04/2021 Mechanical Base $15.00 05/04/2021 Processing/Technology Fee $25.00 05/04/2021 Credit Card Surcharge $4.20 Total Due: $144.20 Total Payment: $144.20 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon AM& ems SAwd"d® HEATING & AIR CONDITIONING Submittal Split System Cooling 2.0 Ton 4A7A3024H1000N [[[[[[[[[[[[[[ [[[[[[[[[[[[[[ lllllllllllllll [ [[[[[[[[[[[[[ fill]lllllllllll [ [[[[[[[[[[[ TAG: t SAFETY WAR Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. December 2014 4A7A3024H-SUB-1A-EN 4#)Ingersoll Rand 4mmP " Slaffdard H EATING & AIR CONDITION ING B SERVICE PANEL C ELECTRICALAND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524(5 FEET) ABOVE UNIT.UNIT SHOULD BE PLACED SO ROOF RUN-OFFWATER DOES NOT POUR DIRECTLY ON UNIT AND SHOULD BE AT LEAST 305(12")FROM WALL AND ALL SURROUNDING SHRUBBERY ONTWO SIDES. OTHERTWO SIDES UNRESTRICTED ELECTRICAL SERVICE K PANEL 'a 25(1) 22.2(7/8)DIA.HOLE A LOW VOLTAGE 28.6(1-1/8)DIA.K.O.WITH 22.2(7/8)DIA.HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPLY LIQUID LINE SERVICE VALVE, E„ I.D.FEMALE BRAZE CONNECTION WITH 1/4"SAE FLARE PRESSURETAP FITTINGS G FIG.I K.O.FOR ALTERNATE ELECTRICAL ROUTING From Dwg.D152898 GAS LINE 1/4TURN BALL SERVICEVALVE, „D„ I.D.FEMALE BRAZED CONNECTION WITH 1/4"SAE FLARE PRESSURE TAP FITTING.A Model Base A B C D E F G H I K 4A7A3024H 2 730 724 651 3/4 3/8 137 65 210 57 457 (28-3/4) (28-1/2) (25-5/8) (5-3/8) (2-5/8) (8-1/4) (2-1/4) (18) SOUND POWER LEVEL Model A-Weighted Sound Full Octave Sound Power[dB] Power Level[dB(A)] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A7A3024H 74 47.9 60.5 1 64.1 71.2 71.2 69.0 58.2 51.5 Note:Rated in accordance with AHRI Standard 270-2008 2 4A7A3024H-SUB-1 A-E N 4mmP " SS'fidard HEATING & AIR CONDITIONING Product Specifications OUTDOOR UNIT(a)(b) 4A7A3024H1000N (a) Certified in accordance with the Air-Source Unitary Air-conditioner POWER CONNS.—V/PH/HZ W 208/230/1/60 Equipment certification program,which is based on AHRI standard 210/240. MIN.BRCH.CIR.AMPACITY 18 (b) Rated in accordance with AHRI standard 270. BR.CIR.PROT.RTG.—MAX.(AMPS) 30 (0 Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. COMPRESSOR DURATIONTM-SCROLL (d) This value shown for compressor RLA on the unit nameplate and on NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit VOLTS/PH/HZ 208/230/1/60 selection current. R.L.AMPS(d)—L.R.AMPS 13.5—58.3 M No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter. FACTORY INSTALLED (f) Standard Air—Dry Coil—Outdoor (g) This value approximate.For more precise value see unit nameplate. START COMPONENTS(e) NO (h) Max.linear length 60 ft.;Max.lift—Suction 60 ft.;Max.lift—Liquid INSULATION/SOUND BLANKET NO 60 ft.For greater length consult refrigerant piping software Pub.No. COMPRESSOR HEAT NO 32-3312-0*(*denotes latest revision). OUTDOOR FAN PROPELLER DIA.(IN.)—NO.USED 18.2—1 TYPE DRIVE—NO.SPEEDS DIRECT—1 CFM @ 0.0IN.W.G.M 2450 NO.MOTORS—HP 1-1/8 MOTOR SPEED R.P.M. 1075 VOLTS/PH/HZ 200/230/1/60 F.L.AMPS 0.90 OUTDOOR COIL—TYPE SPINE FINTM ROWS—F.P.I. 1-24 FACE AREA(SQ.FT.) 12.89 TUBE SIZE(IN.) 3/8 REFRIGERANT LBS.—R-410A(O.D.UNIT)(9) 4 LBS.,11 OZ FACTORY SUPPLIED YES LINE SIZE—IN.O.D.GAS(h) 3/4 LINE SIZE—IN.O.D.LIQ. 3/8 CHARGING SPECIFICATIONS SU BCOOLI NG 10OF DIMENSIONS H X W X D CRATED(IN.) 30.1 x 26.7 x 30 WEIGHT SHIPPING(LBS.) 150 NET(LBS.) 130 4A7A3024H-S1JB-1 A-E N 3 Aw eao S7imd rd® HEATING & AIR CONDITIONING Mechanical Specification Options General Compressor The Outdoor Units are fully charged from the factory The compressor features internal over temperature, for up to 15 feet of piping.This unit is designed to pressure protection and total dipped hermetic motor. operate at outdoor ambient temperatures as high as Other features include: Centrifugal oil pump and low 11YE Cooling capacities are matched with a wide vibration and noise. selection of air handlers and furnace coils that are AHRI Condenser Coil certified.The unit is certified to UL 1995. Exterior is designed for outdoor application. The outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protected on all four Casing sides by louvered panels. Unit casing is constructed of heavy gauge,G60 Low Ambient Cooling galvanized steel and painted with a weather-resistant powder paint on all louvered panels and prepaint on all As manufactured,this system has a cooling capacity to other panels.Corrosion and weatherproof CMBP-G30 55°F.The addition of an evaporator defrost control base. permits operation to 40°F.The addition of an evaporator defrost control with TXV permits low Refrigerant Controls ambient cooling to 30°F. Refrigeration system controls include condenser fan, Thermostats—Cooling only and heat/cooling (manual compressor contactor and high pressure switch. High and automatic change over).Sub-base to match and low pressure controls are inherentto the thermostat and locking thermostat cover. compressor.A factory supplied liquid line drier is standard.Some models may require field installation. Evaporator Defrost Control — See Low Ambient Cooling. c iI . us Unitary Small AG IISTEO Intertek Am of few SAWdArd, H EATIN G & Al R CON DITION ING American Standard optimizes the performance of homes and buildings around the world.A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments,American Standard offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information,visit www.americanstandardair.com. American Standard has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2012 American Standard Heating&Air Conditioning Supersede-SUB New) -EN 19 Dec 2014 "AR Ingersoll Rand Supersedes(New) Permit#: 3864 Permit Date: 05/04/21 Permit Type: RESIDENTIAL MECHANICAL Project Name: Gaynor Applicant Name: CM Heating Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett,WA 98201 Contact: Kailana Phone: 425-259-0550 Email: Kailana@cmheating.com Scope of Work: Ac installation Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 05/04/2021 Permit Expires: 11/01/2021 Form Permit Type: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning GAYNOR GORDON 100 SINGLE 00928200007400 19413 45TH DR NE FAMILY &ANGELA RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Plumbing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751W ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION UBI 605890285 ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 05/12/2021 R04.PLUMBING AC 05/13/2021 05/13/2021 BUILDING Approved GROUNDWORK Fees Fee Description Notes Amount Inspection $75.00 Air Cond.Unit Btu/h<100>; $25.00 Btu/hp>500 Mechanical Base Permit Fee $15.00 Processing/Technology $25.00 Credit Card Service $4.20 Total $144.20 Attached Letters Date Letter Description 05/04/2021 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 05/04/2021 john giacomi 86401676 $140.00 05/04/2021 John Giacomi 86401676 Jennifer Pittman $4.20 Outstanding Balance $0.00 Uploaded Files Date File Name 05/05/2021 8743419-3864 Issued Permit.pdf 05/04/2021 8736771-3864 Specs.pdf 05/04/2021 8736772-3864 Application.pdf