Loading...
HomeMy WebLinkAbout6615 172ND ST NE_BLD1230_2026 Y COMMERCIAL MECHANICAL • PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE • Arlington,WA 98223 • Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IF APPLICABLE. Type of Permit: �✓ New Installation ❑ Replacement ❑ Alteration Project Address: 6615 172nd Street Arlington, WA 98223 Parcel #: Place a 500 LPG tank and dispenser. Project Description: Valuation:2,200 Owner:Washington Trucking Inc. Phone#:425-259-5115 Address: 6615 172nd Street City: Arlington State:WA Zip:98223 Email Address: kriswti@yahoo.com rian jonnson 253-345-1015 Contact Person: Phone #: Address:2320 Milwaukee Way City:Tacoma State: WA Zip: 98421_ Email Address:bjohnson@gotoapp.com Contractor Name:Associated Petroleum Products Phone#: 253-627-6179 Contractor Address: 2320 Milwaukee Way City:Tacoma State:WA Zip:98421 Email:bjohnson@gotoapp.com Contact Person: Brian Johnson Contractor License Number: CCASSOCPP989LJ Expiration: 6/11/2018— Please indicate type of number of appliances: FURNACE CONDENSING UNIT GAS PIPING OUTLET BOILER HEAT PUMP(multi-split) UNIT HEATER CHILLER HEAT PUMP(mini-split) PAINT BOOTH COOLER HEAT PUMP (other) TYPE I HOOD AC(air cooled) HEAT REJECTION EQUIP TYPE II HOOD AC(water cooled) VENTILATION SYSTEM AST AC(evaporator) PACKAGED UNIT UST AC(VRF) DRYER OTHER X I hereby certify that the above infor ation is correct and that the construction on, and the occupancy and the use of the above- described property will be in a nce with the laws, rules and regulation of the State of Washington. Applicants Signature: Date Applicants Printed Name: FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received 6/16LP Page 1 of 1 4W, , OPERATING PERMIT APPLICATION Appendix A Hazardous Materials Storage Department of Community& Economic Development City of Arlington•18204 59th Ave NE•Arlington,WA 98223•Phone(360)403-3551 ■ An Operating Permit is required when a hazardous material listed in any of the categories in tables 5003.1.1 (1), 5003.1.1 (2), 5003.1.1 (3), or 5003.1.1 (4) of the Fire Code is manufactured, stored, or handled; and the quantity of such hazardous material exceeds the quantity listed in the applicable table. o This includes any building that is, whole or in part, a"Group W occupancy; is a pre-existing and non-conforming hazardous occupancy; or has outdoor use of, manufactures, and/or stores materials that exceed the tables for physical and/or health hazard. • An Operating Permit will not be issued until an inspection has been performed and establishes,to the satisfaction of the Fire Marshal,that the requirements of the Fire Code are satisfied; including provisions and requirements regarding manufacture, use,and storage,listed in Chapter 50 of the Fire Code. o A previous fire safety inspection will not wave this requirement. • Tests necessary to verify compliance with the Fire Code must be performed by the applicant, and the reports of such tests must be provided to the Fire Marshal. These tests and reports vary from product to product; however,they must include the following requirements: ❑Verification of inspection of the fire protection systems ❑Verification of inspection of storage cylinders,tanks, or containers ❑ Presentation of Material Safety Data Sheets (MSDS) ❑Verification of compliance with any other applicable State Agency Revised 9/2016 OPERATING PERMIT APPLICATION Department of Community& Economic Development City of Arlington•18204 59th Ave NE•Arlington,WA 98223•Phone(360)403-3551 Part I Applicant/Building InformlIatiion Applicant's Name: �S rr�o• l 1��✓Z��¢tt van P✓Gd�.u/ Applicant's Address: Z 3 Z() i'�; �uavt c� ��a-� . �� Usk fgyz 1 Contact Person: �,<,�,� �� �„5,;�) Telephone: Z53— 3Ll Address of Premises for which Operating Permit is requested: ❑ Same as above ❑ Other(specify): Tax Parcel ID#: Current Occupancy Class: Part II Type of Operating Permit An Operating Permit is required to conduct any activity or to use any class of building listed below. Please indicate the type(s)of Operating Permit(s)requested by checking each applicable box. (If you require assistance, or would like more information, contact the City of Arlington Building Department at 360-403- 3551.) ❑ Manufacturing, storing or handling hazardous materials in quantities exceeding those listed in the Fire Code (see Appendix A.) Identify the materials and quantities and describe the manner in which the materials will be manufactured, stored or((handled(attach additional sheets if necessary):�I � exr Q Q("t(A IL- �(�(� ,4(-,o r•lvkN-e et�/1P NSA✓ T�tR /yC� Revised 4/l/08 Page 1 of 4 Part H(cont'd) ❑ Conducting a hazardous process or activity, including, but not limited to, any commercial or industrial operation which produces combustible dust as a byproduct, fruit and crop ripening, waste handling, spray operations, and high-piled storage (see Appendix B.)Describe the process(es) or activity(ies)to be conducted (attach additional sheets if necessary): ❑ Use of pyrotechnic devices in assembly occupancies (see Appendix C.)Describe the devices to be used and type of event(attach additional sheets if necessary): ❑ Aboveground Storage Tank(AST)(see Appendix D) ❑ Removal ❑ Decommissioning ❑ Temporary tank closure ❑ Changes in service ❑ Permanent tank closure Brief description: ❑ Underground Storage Tank(UST) (see Appendix D) ❑ Removal ❑ Decommissioning ❑ Temporary tank closure ❑ Changes in service ❑ Permanent tank closure Brief description: ❑ Temporary Membrane Structures, including tents and canopies(see Appendix E.)Brief description of structure and use: Cc: Fire Department Page 2 of 4 Part II(cont'd) ❑ Special Event Operating Permit-An Operating Permit is required for any special event that takes place within an occupied building, or an outdoor mass gathering,which is outside the scope of the permitted use(see Appendix F.)Brief description of type of gathering proposed: Part III Premises/Building Information 1. Date of last inspection of Premises: 2. Has a Certificate of Occupancy been issued for the premises?Lfj Yes ❑No Type: ❑ Permanent ❑ Temporary Date of Issuance: 3. Are there currently any open Building Permits associated with the premises? ❑ Yes ❑No If yes, please describe (attach additional sheets if necessary): 4. Additional Comments: SIGNATURE OF APPLICANT I herby certify that the foregoing information (and all information in attached sheets, if any) is true and complete. Signatur pplicant or Authorized Representatives Signature Date Name and Title (if applicable)of person signing Application (Please print) Cc: Fire Department Page 3 of 4 Part IV To be completed by the City of Arlington Building Department Inspection Required: ❑ Yes ❑No Inspections Performed: ❑ Yes ❑No Date of Inspection: Tests or Reports required verifying compliance? ❑ Yes ❑No If YES, have Tests or Reports been received? ❑ Yes ❑No Application(s) Approved: ❑ Yes ❑ No Operating Permit Issued by: _ Date Operating Permit Issued: Date Operating Permit Expires: Type/Description of Operating Permit: Conditions of Operating Permit(list conditions here AND in the space provided in the Operating Permit): Additional Comments: (Attach additional pages if needed) Cc: Fire Department Page 4 of 4 CITY OF ARLINGTON e; 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:6615 172nd Street Permit#:1230 Parcel#:31052200401100 Valuation:2200.00 OWNER APPLICANT CONTRACTOR Name:WTI LLC Name:Associated Petroleum Products Name:Associated Petroleum Products Address:2810 34TH ST Address:2320 Milwaukee Way Address:2320 Milwaukee Way City,State Zip:EVERETT,WA 98201 City,State Zip:Tacoma,WA 98421 City,State Zip:Tacoma,WA 98421 Phone: Phone:253-345-1015 Phone:253-627-6179 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Associated Petroleum Products Name: Address:2320 Milwaukee Way Address: City,State,Zip:Tacoma,WA 98421 City,State,Zip: Phone:253-627-6179 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded 'y of Arlington#3101, i Signature Print Name We Released By tc CONDITIONS Final inspection is required prior to filling of tank. Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 12/8/2016 Mechanical Permit Base Fee $25.00 12/8/2016 Mechanical Plan Review Fee $200.00 Total Due: $225.00 Total Payment: $0.00 Balance Due: $225.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Project: Set 500 LPG tank and dispenser Address: 6615 172"d Street NE Arlington,WA Contractor: Associated Petroleum Products Contractor Licsense: CCASSOCPP989U Contact: Brian Johnson 253-345-1015/bjohnson@gotoapp.com 1 6 5 e O 'St NE N �J L LPG Tank Site � - r - 53T Project: Set 500 LPG tank and dispenser Address: 6615 172"d Street NE Arlington,WA Contractor: Associated Petroleum Products Contractor Licsense: CCASSOCPP989U Contact: Brian Johnson 253-345-1015/ bjohnson@gotoapp.com *Concrete Ecology blocks to be set around the tank at 3 feet off the tank and no greater hat 3 feet spacing in between blocks. 1.) 60 feet to wash rack 2.) 55 feet to tracks, 30 feet to property line 3.) 42 feet to office building ate: IUSyr••+fit; � t imam r ! rr� a`oma M`ii .•� � .A.• • LJ err 1 � • �t1= -r TRINITY CONTAINERS AO DOMESTIC TANKS �_- OVERALL LENGTH LIQUID DOME WITHDRAWAL -RELIEF I VALVE l' 2 -' OUTSIDE I + DIAMETER it o u � I I I LEG *PLUG i- WIDTH LEG SPACING General Specifications Conforms to the latest edition and addenda of the ASME code for Pressure Vessels, Section VIII, Division 1. Complies with NFPA 58. ;�jC� l NOTICE Rated at 250 psig from-20' F.to 125' F.All tanks may be i LP GAS FILLER VALVE ! evacuated to a full (14.7 psi)vacuum, i r Vessel Finish: Coated with TGIC powder. FLOAT Liquid withdrawal opening located under the dome on the GAUGE NAME 120wg vessels ONLY. SERVICE/ PLATE I MULTIVALVE --� ABOVEGROUND VESSEL DIMENSIONAL INFORMATION All vessels dimensions are ap roximate WATER OUTSIDE HEAD OVERALL OVERALL LEG LEG QUANTITY CAPACITY DIAMETER TYPE LENGTH HEIGHT WIDTH SPACING WEIGHT FULL PER LOAD STACK ! *120 wg. 24" Ellip 5'-5 13/16" 2'-8 1/4" 10 1/8" T-0" 245 lbs. 96 12 454.2 L 609.6 mm 1671.6 mm 819.2 mm 257.2 mm 914.4 mm 111.1 kg. "250 wg. 31.5" Hemi T-2 1/2" 3'-3 3/4" 12 3/4" 3'-6" 472 Ibs. 63 9 946.3 L 800.1 mm 2197.1 mm 1009.7 mm 323.9 mm 1066.8 mm 214.1 kg. *320 wg. 31.5" Hemi 8'- 11 314" T-3 3/4" 12 3/4" 4'-0 1/4" 588 Ibs. 45 9 ! 1211.2 L 800.1 mm 2736.9 mm 1009.7 mm ' 323.9 mm 1225.E mm 266.7 kg. 500 wg. 37.42" Hemi 9'-10" T-9 11/16" 15" 5'-0" 871 lbs. 30 6 1892.5 L 950.5 mm 2997.2 mm 1160.5 mm 381.0 mm 1524.0 mm 395.1 kg 1000 wg. 40.96" Hemi 15'- 10 13/16" 4'- 1 3/8" 16 1/4" 9'-0" 1729 lbs. 15 5 3785.0 L 1040.4 mm 4846.6 mm 1254.1 mm 412.8 mm 2743.2 mm 784.3 kg 1465 wg. 46.77" Ellip IT-6 7/8" 4'- 4 3/4" 21" lot- 0" 2745 lbs. 12 4 5545.0 L 1188 mm 5356.2 mm 1339.9 mm 533.4 mm 3048 mm 1245 kg 2000 wg. 46.77" Ellip 23'-9" 4'- 7" 21" 20' - 0" 3676 Ibs. 8 4 7570.0 L 1188 mm 7239 mm 1709.7 mm 1 533.4 mm 6096 mm 1 1667.5 kg DRAIIJ PLUG NOT AVAILABLE �__ _�_a_. -Al r gnev - ..• -....... x I WY We have redesigned ourf.3209RSeries intemal valves;the new par t Designed primanly for use with LP-Gas and anhydrous ammonia as a number will be A3209D Series the rest price will not change, rain valve on smalFcaoacity pumping systems,NH3 nurse tanks and Your order For the A3209RO50 and A3269ROSO will be changed to I w In-line installations. It may also be installed in the vapor equalizing the new part numberfor orders scheduled as follows: Opening an bobtail delivery trucks_Installation is quick and easy and s it ns in both full and 'half couplings,as well as, in-line applications_ A3209R050 to A3209D0$11:your onier scheduled for delivery after I The valve may be actuated manually by hand or cable. u� June 2007. Features A3209R0&0 to A3209D080:your order scheduled for delivery after February 2007• Valve is comoact,with one piece body construction. We have developed a new Tee stye A32D9DT050 and A3209D 1080 teat Spring loaded VIpacking with heavy duty wiper ring on operating vwll replace u eA3210A065.The L;st price for this valve is:S 417•_30 • shaft for dependable leak-free construction. sa Nylon bearing supported operting shaft provides smooth, easy operation. RHF Simple operating fever allows for easy connection of cable controls. Lj • Built in excess flow valve �P .. 4 O Return spring forces the valve to the closed position when the _ Ol lever is released. x�l.�• O All cFffical operating components are located in the valve body and inside the container coupling for ma)dmum pmtecbon against damage. Iviidv,d-y stem position allows for quick pressure equalization. / A3209DT Equipped with 2 12'F, UL listed fuse Gnk for thermal protection. A. r �- Material 3< Body............................__....... _. . . .... .� Ductile Iron Operating Lever--------------------------- Cadmium Plated Carbon Steel Stem _ _ _ �._ _. Stainless Steel a Springs------------------------------------------------------------------ Stainless Steel �•..r. �_. Too View ! Seat Disc.......... _. Resilient Synthetic Rubber ShaftBearing.......................... ---------•-••-................... Nylon A3209D Seat disc fully retained and i i q I held 2placaable m �Fn A-AZZML50 1 K, b s �+za000ao - it I t It ! 2D i Nd Cotk.p' I i 4'F_ o ' I I t 11 r 4• -.4 4 er Ir, 1 0 Cam attached with Allen x I 1 head fastener which is I i� accessed from the 14"pipe piug on side of the body °J 2 3 A 5 5789.1 t 3 4 s crE 10 m s 40 D,.pT_V.1-rP-q ND 1 c Muraply fa.rate by 94 m dmt---e rtouid buiere flow Ordera»g Infoa•rr;/atEoa;; aid by SD to*Awrrnte Squid ardry�s ammone low. _ - :,:�'�Win.- - -�; - _• - .�. - .� - T ��� ,err A32D9Dn50 1'/." 1'/<" �50� 45V 13,300 � 22,900 A32D.9D090 1YA" 11,7." BO 72 15,7D0 26,700 A3209PA A32D9DTD50 1'/." 1''/.' S0 45 13,300 22,90D A3209TL A32D9PAF A32n9D T o80 1/" 11W 80 72 15,7D0 26,700 G8 59a, Enoineered controls Inia-mhor1,6ic100 ReoO Dr..P.C.6=24i Elor„NC Z7244 US:, www.rt?�aprod�ds.con Phone(�6)"—;��T FG(336J 49v594 �_ W -gar'MMill, No Application -- - Designed for use as a primary refief valve on ASME containers such g >; as 250.500 and 1,D00 gallon tanks.Underwriiers'Laboratories lists - C containers systems on which these types of valves are mounted outside the hood without additional protection, if mounted near file �. A hood and flited with a protective cap. Constructed of nor-corresive materials. "Pop-action"design keeps product lass of a minimum. n ASME rated for use Kfth LP-Gas. Request Rego@ Refief Valves on all your original eguipmentASNE a atee iags containers for reliable perfomance_ Body--•---------------------- ---- -------------------------------------------- Brass Spring ----------------------------------•------------------------ St>5-1 Stem-----------------------------------------------------------.......... Stainless steel Seat Disc_.......-...--------------—------------------—--------- Resiilerrt Rubber Ordering Information -_ _ _�•• .\--. . - -� :r�.�> -_ __ -_.� � >.� .Gib 75B3G l %' B E T'.' ! t%' 1980 18D6 B0 Sa.FL 7583-40X 8654G 250 1' � 9�• 1°;� 1%," 262D 2565 113 Sq-Ft 8684-4II 86ESG --1'/<<'— j 11;5. "PY�' 2'/," 4385 ` 4035 212 Sq-Ft_ 7585-LOX • Per NFPA Pamphlet 45E,Appor)d=G_Area shown is for UL or ASME now larger. Appiicny or 3'NT Designed especially for use as a primary relief valve on large 3133 \ stationary storage gontainars, 'These low profile relief, valves are generally mounted In half couplings_However,they are designed so Hole that the inlet porn clear the bottom of a full 2'coupling.I his assures Deflector that the relief valve should always be capable of maximum flow under emergency conditions. _ wrenching y lop of HE- f Coupling Features High capacity,low turbulence design has a maximum guiding area .aa 201A' r providing for dependable shut-ul after opening. 2"NF F 1. rcx h, Built-in spring stop 6mis the rise of the seat in full open position t- and prevents the spring from going`solid'. External 3" NP-threaded 'body allows easy attachment of vent — stacks. Optional pioeaway adapter has break-off groove to prevent damage to the nalief valve should piping be stressed by damaging winds. Materials � ' i "Pop-Action'design keeps product loss at a minimum. Body..__...._...___.._.._._......................_...._.�._._..__.._......__._. grass I! No guiing projec5ons around the seat disc retainer to bind and Spring.._._...____._.._......-__.... Steel hinder opening of valve'ri body is damaged_ Stem— — --- •------------—- - ------------ ------ stainless Steel Seat —----------- Resifient Rubber Ordering hiformation to-_- .� .--• '�' , 75346 125 6,025 - 31-4 Sq.Ft 7534G 250 2 11,675 1D,422 1 7D8 Sq.FL 7534 40 75?4 20" 'Row rates shown are for barn_ref vak­4jdep5rs and pipeaways will reduce flow as dszvssed in the forewordn9 in(om,Pion_ Per NFPF Pamphlet 6,Appendix Q.A o shown is(or'JL or ASME-�.vhiciev�is large:. "T F.NPT outlet m me_tion. 013 Mg Mz Enoineered Cord oL Intamational,lnLiw Rego Dr.P,o,Sox 2C Ban,NC 2.7244 USA w _regopmduais m Phone(336)4-0L�-r.07 Fa;i-36)4�55�4 =� _ PRQQII�T , i €ice. Hose High Pressure LPG Hose 350 psi maximum working pressure. UL listed.7 1 32-25354E-350 sized for shipment by UPS. Par[no. S¢e LID. S¢e D.D. SDiralll-r-id Wt,/100 Senderd LLd _ Reel S"¢e Prim/foot 7132-253a4 i/4° 7164" 4 spiras 14 Ibs. 7D0' $1.66 132 series 7 i 3S 32-254E•350 1/4' 7/64' 4 spirals 14 Ibs. 359 S�,-45 7132 83S4 I 3/s• 3/4` 4 spirals 22 ms. ;,D' S3-04 t 71a2-SC 54 1/2 f 15/10 4 spirals 3o lbs 459 &24 7 132-'&3�, 3/4` I i%<' 4 spirals 42 Ibs. 30V I �B-04 7132-1D3a54 1° 114' 4 spirals 62 Ls. ) 25U S7S0 _ braids 96 1� 3D0' S15B4 7232 Ssrias 72v'2-1503 VA, 23,e' 3 braids ' 114 lbs. 159 $26.76 ' + 7c32-20x 2° Tbfi 3 braids 1z2lbs_ 150' �e0.12 High Pressure LPG Hcse- Stainless Steel RF-4 fDrced Rubber cover. 350 psi merimum working pressure. UL Listed. Cut lengths-bulk lots 300' to 4-00'. i—.h no- Sim-LD. Srze D.D. Braid WelglT 100 Standard Lisa 7 Series k Re:=_-I Size Pricy-, got 72MC-311 5/16' 43/64' 1 is h& 500' $420 7231-751 3/4' 1Y<° 1 59lbs_ 100' $3.0.98 T—MI-1D01 1' VA, 1 io Ibs 100 -$44.rB 7221-1251 11/1' I'W 1 22lb- 1.00' $4832 /231-1501K i,/- 2° 1 ii3lb<. 150 S68_BB _ 7231-2002K 7 2m/.' 2 1EF/lbs. 150' $'102Z-4 7231 Series00 - � High Pressure LPG Garburetion Hose-Stainless Steel Reinforced I eKdle braid cover. 350 psi ma imum worldrig pressure. UL Listed. Cut IenlY:s-bulk lots 300'to 400'. Part no. Sty I.D. 5¢e D.D_ Weighth00 it List Pric�Jfoot FG321 -04 1/47 3:3/64" 11 Ibs- �5,44 0-ass ! FC°a21-08 1/2` 49/E4' 21 Ibs $6.46 -rt: _ Fw21-12 3/4. 1 15{u` .sr Ibs raso yy�� Low Pressure General 'Purpose Hose-Red. LP-Gas vapor-only service. Recommended working ressure 125 psi. Rubber coated. _ Part no. Spirals See I.D. Size 0-D.Weighi/100 Standaly ReJ Size Price/foot � 7122.362 2 3/F 21,/3 145 Ibs. 559 1 $236 - - - LPG Vapor/Water Hed er Hose Part no. Size I.D. StandardPackage Pius List Prir=Jfoot VH 5B ! 5!6' 30' 3 I �•4LT e-4 _ �v z y_ m VI 34 3/4' , 30, 3 $9-BD - VF-78 7/6' 30, 3 i $S.OD V!--100 1' I 30' 3 1 $°.60 VI- 11,2 11fz' 30' 3 i $10.72 Vacuum 'Hose Part no. Descr bon IDS Pricma oat s �' - !sr , 340-VH Vaaaum hose,31115" I.D. i tI-02 _9� 341-V I Vacuum hos,11a^l_D. S132 Il I 342-VH Vaeium hose,31F!-D. Prix s blea to rams=wfthoui node Same itE-rs may nol ba in .^' E1 BV. 9/2��/ I- 2d all war�tousa or may be soecel order.Plzese d ie�Mth 1 F—�. (� G Online, •e'-t rder unvw,tee=products.com Sacramento, aA Rapid Gi:-y, SD Aubun,WA e-mail: info,@teeecopr-ocuctss-com (500) 225-6621 (B00) 843�8660 (BOO) 42E-9456 (°1 j I• r, c i ���'---. + A G!!.^c--._—_ + 1 +I I �! �I1�:,�{ I i+ + �R�i- yc --� .s- _ i —_ _J 1-�y �• � I y'-..�����`9y�� � _ .-�� -Y -ALL �� ��.�.�� `.r�fy�"§..,vs.. -_ �. _ .mac�.SS �•' .�'- � _:�- .����'��+.. MOE �e 7554S Series valves provide instant shut-oft and fist opening control 1 ideal for charging manifold on LP-C:as mop driers.They are also 9 ng hoses,stationary fuel transfer hoses and other applications requiring t- quicK positive shut-off.They are not for use with delivery truck hoses because the handle could snag on the ground and open the valve as k the hose is reeled back to the truck J _ �355' 7554L Series valves feature a locking handle device to help prevent - = = accidental opening of the valve.It is ideal for all the same applications �c as the 7554S Series and may be used on delivery trucks as it incorporates the locking handle design. �.aate r .p Both valve series must be installed so that now through the valve is 3�� at opposite tO th of a conventional glo')e valve.This allows the'Inlet - floW ID assist in closing.the valve and prevents the>r?Ive from being TSB ee opened-by high pump pressures. °`'--�� --------° Features 3'° Quick-ac'dng design speeds t-nsfer operaions, permithng rapid, �L one-handed opening and closing. Resilient seat disc provides positive shlt-off- Fange seal stem design provides for leak-proof operation- No packing to retighten or replace. II t�'Y,►� 755A.L Series incorporates locking handle to prevent accidental opening of the valve. Vent valve installed on the downstream side of the valve permits _ bleeding of trapped product to assure safe uncoupling- Swivel seat disc minimizes grinding on the body seat and assures Q longer Service life. Materials Body_-----•--•---- ............ Ductile Iron Bonnet-------------------------------------------------------------------------------------- Brass W'-Ring.---•----•-----...--.-•--••-----_---------------------------------•-••-_-•--- Won Stem.___......--------------------_----------------------------------- Stainless Steel 7554LV Seat Disc..__.......... ---••................................ Synthetic Eastomer ACME Connector---•-.•---------_----_--.-----.--.-_. .Alumintrrrl w/Steel Insert Seal Housing----------------------------------------------------------- Stainless Steal O Lever•-•-------••-•-- ------------------------.................. Stainless Steel 3'r5s' (;B o - � • ••- ! Inlet • yy I - I 1 r--lafx'�I dsri n3q Information _ y 75:.,4-.S AV +, No I 7.3 I 7554LA�i / YES -155a'a'd _ No 113 7-540) Yes To obtain:ooroamate Bow at othc then 1 PSIG PnusSuft drop,mulrioly flow in table by sa-re roU of p___�ra Crop-pram*:7554UJ Ira-9 PSIG-11 5 X propane. E C l C ! 119VA'F._l�=r: rni—ii—I Inc 100 ReoO Dr.P.O.S=247 Jan,NC ZTZ"i USA www.regopmduct�=m Phone('tab'44Q-7707 =a;(336)449-E_�-4 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:6615 172nd Street Permit#:1230 Parcel#:31052200401100 Valuation:2200.00 OWNER _ APPLICANT CONTRACTOR Name:WTI LLC Name:Associated Petroleum Products Name:Associated Petroleum Products Address:2810 34TH ST Address:2320 Milwaukee Way Address:2320 Milwaukee Way City,State Zip:EVERETT,WA 98201 City,State Zip:Tacoma,WA 98421 City,State Zip:Tacoma,WA 98421 Phone: Phone:253-345-1015 Phone:253-627-6179 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Associated Petroleum Products Name: Address:2320 Milwaukee Way Address: City,State,Zip:Tacoma,WA 98421 City,State,Zip: Phone:253-627-6179 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: W PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALFS TAX NOTICE.-.Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded Ci of Arlington#3101. Signature Print Name bale Released By < L3atc CONDITIONS Final inspection is required prior to filling of tank. Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 12/8/2016 Mechanical Permit Base Fee $25.00 12/8/2016 Mechanical Plan Review Fee $200.00 Total Due: $225.00 Total Payment: $0.00 Balance Due: $225.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following inrormation: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon i Permit Information Date 12/7/2016 Permit Number 1230 Project Name Washington Trucking Applicant Name Associated Petroleum Products Applicant Address 2320 Milwaukee Way City, State,Zip Tacoma,WA 98421 Contact Brian Johnson Phone 253-345-1015 Email bjohnson@gotoapp.com Permit Type Commercial Mechanical Site Address 6615 172nd Street Valuation 2200.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use Install 500 gallon propane tank Assigned To Kristin Foster Property Information Owner Information Parcel#:31052200401100 WT1 LLC WT1 LLC 2810 34TH ST 6615 172ND ST NE EVERETT,WA 98201 Review Date Type Description 1 Target Date I Completed Date IAssigned To Status 12/7/2016 iCommercial Mechanical 12/14/2016 1 lKevin Olander 111n Review Uploaded Files Upload File J Date File Uploaded B 12/7/2016 9:57:46 AM 1230 Tank Location.pdf (Foster,Kristin 12/7/2016 9:57:46 AM 1230 Applications.pdf (Foster, Kristin 12/7/2016 9:57:45 AM 1230 Tank Specs._ df (Foster, Kristin I ,� , - I 4 �•.iY CC JIMERCIAL MECK_1NICAL • PERMIT APPLICATION .y Department of Community& Economic Development City of Arlington• 18204 59th Ave NE • Arlington, WA 98223 • Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS AND ALL OTHER INFORMATION OUTLINED IN THE MECHANICAL PERMIT SUBMITTAL REQUIREMENTS, IF APPLICABLE. Type of Permit: W New Installation Replacement Alteration Project Address: 6615 172nd Street Arlington, WA 98223 Parcel #: Place a 500 LPG tank and dispens-er. --- 2,200 Project Description: _ Valuation: ' Owner:Washington Trucking Inc. Phone#:425-259-5115 Address: 6615 172nd Street City: Arlington State:WA Zip:98223 Email Address: kriswti@yahoo.com nan onnson - - 253-345-1015 Contact Person: Phone #: Address: 2320 Milwaukee Way City:Tacoma State: WA Zip: 98421 Email Address:bjohnson@gotoapp.com Contractor Name:Associated Petroleum Products Phone #: 253-627-6179 2320 Milwaukee Way Tacoma WA 98421 Contractor Address: City: __ State: Zip: Email:bjohnson@gotoapp.com Contact Person: Brian Johnson Contractor License Number: CCASSOCPP989LJ Expiration: 6/11/2018 Please indicate type of number of appliances: FURNACE CONDENSING UNIT GAS PIPING OUTLET BOILER HEAT PUMP(multi-split) UNIT HEATER CHILLER HEAT PUMP(mini-split) PAINT BOOTH COOLER HEAT PUMP(other) TYPE I HOOD AC(air cooled) HEAT REJECTION EQUIP TYPE II HOOD AC(water cooled) VENTILATION SYSTEM AST AC(evaporator) PACKAGED UNIT UST AC(VRF) DRYER OTHER X hereby certify that the above info ation is correct and that the construction on, and the occupancy and the use of the above- described property will be in a r nce with the laws, rules and regulation of the State of Washington. Applicants Signature: Date !n Applicants Printed Name: �f Ih� 6N 50r� Re-calloGid � 'I FOR STAFF USE ONLY �'✓U DEC 06 2016 Permiil# pt Amount Received Heceopt# Date Received 6/16LP Page 1 of 1 � �� �. I I OPERATING PERMIT APPLICATION Appendix A Hazardous Materials Storage Department of Community& Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223•Phone(360)403-3551 • An Operating Permit is required when a hazardous material listed in any of the categories in tables 5003.1.1 (1), 5003.1.1 (2), 5003.1.1 (3), or 5003.1.1 (4) of the Fire Code is manufactured, stored, or handled; and the quantity of such hazardous material exceeds the quantity listed in the applicable table. o This includes any building that is,whole or in part, a "Group H"occupancy; is a pre-existing and non-conforming hazardous occupancy; or has outdoor use of,manufactures,and/or stores materials that exceed the tables for physical and/or health hazard. • An Operating Permit will not be issued until an inspection has been performed and establishes,to the satisfaction of the Fire Marshal,that the requirements of the Fire Code are satisfied; including provisions and requirements regarding manufacture, use, and storage,listed in Chapter 50 of the Fire Code. o A previous fire safety inspection will not wave this requirement. ■ Tests necessary to verify compliance with the Fire Code must be performed by the applicant,and the reports of such tests must be provided to the Fire Marshal. These tests and reports vary from product to product; however,they must include the following requirements: ❑Verification of inspection of the fire protection systems ❑Verification of inspection of storage cylinders,tanks,or containers ❑ Presentation of Material Safety Data Sheets (MSDS) ❑ Verification of compliance with any other applicable State Agency Received Revised 9/2016 DEC 06 �oI6 010111_mil/ it I I } � i'. OPERATING PERMIT APPLICATION Department of Community& Economic Development City of Arlington•18204 59th Ave NE•Arlington,WA 98223•Phone(360)403-3551 Part I Applicant/Building Information Applicant's Name: Applicant's Address: Z3 Zt) N1;j,L,&A fgiYz Contact Person: -trap-& 1 Telephone:_ 7— Address of Premises for which Operating Permit is requested: ���3 r'7Z" ��AAe �'' � WA- 9Vzz 3 ❑ Same as above ❑ Other(specify): Tax Parcel ID#: Current Occupancy Class: Part H Type of Operating Permit An Operating Permit is required to conduct any activity or to use any class of building listed below. Please indicate the type(s) of Operating Permit(s)requested by checking each applicable box. (If you require assistance, or would like more information, contact the City of Arlington Building Department at 360-403- 3551.) ❑ Manufacturing, storing or handling hazardous materials in quantities exceeding those listed in the Fire Code (see Appendix A.) Identify the materials and quantities and describe the manner in which the materials will be manufactured, stored or !handled(attach additional sheets if necessary):: L JO— GI,P'Q Q1(�.l.�lvL, � �!�(� tic�D� p.?JpQ,N-� ''�'�,�1� {- G�1 t�eN��✓- I blR ��lv(� Revised 4/1/08 Page 1 of 4 i Part H (cont'd) ❑ Conducting a hazardous process or activity, including, but not limited to, any commercial or industrial operation which produces combustible dust as a byproduct, fruit and crop ripening, waste handling, spray operations, and high-piled storage (see Appendix B.) Describe the process(es)or activity(ies)to be conducted (attach additional sheets if necessary): ❑ Use of pyrotechnic devices in assembly occupancies (see Appendix C.)Describe the devices to be used and type of event(attach additional sheets if necessary): ❑ Aboveground Storage Tank(AST) (see Appendix D) ❑ Removal ❑ Decommissioning ❑ Temporary lank closure ❑ Changes in service ❑ Permanent tank closure Brief description: ❑ Underground Storage Tank(UST)(see Appendix D) ❑ Removal ❑ Decommissioning ❑ Temporary lank closure ❑ Changes in service ❑ Permanent tank closure Brief description: ❑ Temporary Membrane Structures, including tents and canopies (see Appendix E.)Brief description of structure and use: Cc: Fire Department Page 2 of 4 i) 1 I Part II(cont'd) ❑ Special Event Operating Permit-An Operating Permit is required for any special event that takes place within an occupied building, or an outdoor mass gathering,which is outside the scope of the permitted use(see Appendix F.)Brief description of type of gathering proposed: Part III Premises/Building Information 1. Date of last inspection of Premises: 2. Has a Certificate of Occupancy been issued for the premises?X Yes ❑No Type: ❑ Permanent ❑ Temporary Date of Issuance: 3. Are there currently any open Building Permits associated with the premises? ❑ Yes ❑No If yes, please describe(attach additional sheets if necessary): 4. Additional Comments: SIGNATURE OF APPLICANT I herby certify that the foregoing information (and all information in attached sheets, if any) is true and complete,,, V-"- N Signaturid Gfkpplicant or Authorized Representatives Signature Date Name and Title (if applicable)of person signing Application(Please print) Cc: Fire Department Page 3 of 4 i i I �� i Part IV To be completed by the City of Arlington Building Department Inspection Required: ❑ Yes ❑No Inspections Performed: ❑ Yes ❑No Date of Inspection: Tests or Reports required verifying compliance? ❑ Yes ❑No If YES, have Tests or Reports been received? ❑ Yes ❑No Application(s) Approved: ❑ Yes ❑ No Operating Permit Issued by: Date Operating Permit Issued: Date Operating Permit Expires: Type/Description of Operating Permit: Conditions of Operating Permit(list conditions here AND in the space provided in the Operating Permit): Additional Comments: (Attach additional pages if needed) Cc: Fire Department Page 4 of 4 I I I I I� Project: Set 500 LPG tank and dispense Address: 6615 172"d Street NE Arlington,WA Contractor:Associated Petroleum Products Contractor Licsense: CCASSOCPP989U Contact: Brian Johnson 253-345-1015/bjohnson@gotoapp.com • • 0 LAG Tank Site . , - 531 CITY OF ARLINGTON BUILDING DEPARTMENT APPROVED �. OFFICE COPY Received DATE/� DEC 0 6 2016 CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING TOR i i VvTrr uuw Project: Set 500 LPG tank and dispenser Address: 6615 172"d Street NE Arlington, WA Contractor:Associated Petroleum Products Contractor Licsense: CCASSOCPP989U Contact: Brian Johnson 253-345-1015/bjohnson@gotoapp.com *Concrete Ecology blocks to be set around the tank at 3 feet off the tank and no greater hat 3 feet spacing in between blocks. 1.) 60 feet to wash rack 2.) 55 feet to tracks, 30 feet to property line 3.) 42 feet to office building �J IN 1 �w &s • rrr►. Ili J I too V �i I II II II ti. TRINITY CONTAINERS AG DOMESTIC TANKS OVERALL LENGTH z2 I`i LIQUID ii'lI ItIIj DOME -RELI`E�F WITHDRA VALVE 0LL u Ii OUTSIDE MRE O �1,r irI!t CT -E - 'PLUG WIDTH emeiv LEG SPACING General Specifications _ Conforms to the latest edition and addenda of the ASME code for Pressure Vessels, Section Vill, Division 1. Complies with NFPA 58. �J F NOTICE LP GAS I \ Rated at 250 psig from-20' F.to 125' F,All tanks may be i FILLER l VALVE evacuated to a full (14.7 psi)vacuum. Vessel Finish: Coated with TGIC powder. 1 FLOAT Liquid withdrawal opening located under the dome on the GAUGE NAME PLATE 120wg vessels ONLY. SERVICE/ MULTIVALVE ABOVEGROUND VESSEL DIMENSIONAL INFORMATION ' All vessels dimensions are approximate WATER OUTSIDE HEAD OVERALL OVERALL LEG LEG QUANTITY CAPACITY DIAMETER TYPE LENGTH HEIGHT WIDTH SPACING UVEIGHT FULL PER j LOAD STACK i *120 wg. 24" Ellip 5'-5 13/16" 2'-8 1/4" 10 1/8" T-0" 245 lbs. 96 12 454.2 L 609.6 mm 1671.6 mm 819.2 mm 257.2 mm 914.4 mm 111.1 kg. " 250 wg. 31.5" Hemi T-2 1/2" T-3 3/4" 12 3/4" T-6" 472 lbs. 63 9 946.3 L 800.1 mm 2197,1 mm 1009.7 mm 323.9 mm 1066.8 mm 214.1 kg. *320 wg. 31.5" Hemi 8'- 11 3/4" T-3 3/4" 12 3/4" 4'-0 1/4" 588 lbs. 45 9 i 1211.2 L 800.1 mm 2736.9 mm 1009.7 mm 323.9 mm 1225.6 mm 266.7 kg. 500 wg. 37.42" Hemi 9'-10" T-9 11/16" 15" 5'-0" 871 lbs. 30 6 1892.5 L 950.5 mm 2997.2 mm 1160.5 mm 381.0 mm 1524.0 mm 395.1 kg 1000 wg. 40.96" Hemi 15'- 10 13/16" 4'- 1 3/8" 16 114" 9'-0" 1729 lbs. 15 5 3785.0 L 1040.4 mm 4846.6 mm 1254.1 mm 412.8 mm 2743.2 mm 784.3 kg 1465 wg. 46.77" Ellip 17'-6 7/8" 4'- 4 3/4" 21" 10'- 0" 2745 lbs. 12 4 5545.0 L 1188 mm 5356.2 mm 1339.9 mm 533.4 mm 3048 mm 1245 kg 2000 wg. 46.77" Ellip 23'-9" 4'- 7" 21" 20' - 0" 3676 lbs. 8 4 7570.0 L 1188 mm 7239 mm 1709.7 mm 533.4 mm 6096 mm 1667.5 kg 'DRAIN PLUG NOT AVAILABLE .. .- - . �I 1 - - = E i' '•�' f- - Ja a W_ We have redesigned ourA32D9R Series ntemal valves:the new par number will be A3209D Series the list price will not change. Designed primanly for use with LP-Gas and anhydrous ammonia as a main valve on small"capacity pumping systems,NH3 nurse tanks and Your order for the A3209R050 and A3269ROBO will be changed to in-line installations. It may also be installed In the vapor equalizing the new part number for orders scheduled as follows: j opening on bobtail delivery trucks.Installation is quick and easy,and ` it tis in both full and 'Half couplings,as well as, in-line applications- A3209R050 to A3209D05D:your order scheduled for delivery after The valve may be actuated manually by hand or cable- June 2007. 1Y� � r A3209RD80 to A3209DOBO: our order scheduled for derive, after t, ?Ec'2aa�r�5 y 'a February 2007, Valve is compact,with one piece body construction. _ We have developed a new Tee style A3209DT050 and A3209DTOBO that Spring loaded V packing with heavy duty wiper ring on operating will replace the A3210A065.The List price for this valve is:S 417•30 shaft for depandable leak-free construction. �- • Nylon bearing supported operating shaft provides smooth, easy ti operation, kka i; Simple operating fever allows for easy connection of cable controls. • Built in excess now valve ,, Return spring forces the valve to the dosed position when the x rr lever is released. f�+ O All critical operating components are iocated in the valve body and inside the container Coupling for maximum protection against damage. �. Midvay stern position allows for quick pressure equalization. A3209DT fl Equipped with 2 12' F, UL listed fuse link for thermal protection. .. a: t Body - Ductile iron ' Operating Lever---------------.------------------ Cadmium Plated Carbon Steel ' Stem...................... »_... _ » ._ ».:..... Stainless Slee_ sa,_,i• -�1� a Springs - - - -- Stainless Steel iK..•r. �-<^� To View p Seat Disc-------...---------....-.......--------------- Resllent Synthetic Rubber �`•ram Sheri:Bearing-----•-•--..._..-•--•--------------------------_----_--•---•---•----- Nylon A3z09D Seat disc fully retained and m •' b nJd replaceable m t' 'O B A-A$L30t50 i v• �! �20I Of I rwr Cady 11 r dw -H a Tom• F • '' ' s 1 1 av a711-11 O� I , i Cam attached with Allen I head fastener which is I ti 1 1� accessed from the 14'pipe r� plug on side of the body As 2 ] A s 5]a9.1 t a 4 sera to m s b D.P•_v.a..IPq NO i c MWtipy tow r�by-44 m detern-M Emrid bLaare flow and by M to 0.0.-T:au Bquid anhorors ammor�Bow. Ordering Inforrnation k1 „ln - �► _r - 1���;e - r1• _,.tip 1 y.' 1'/z 50 45 13,300 22,900 ind A3209 DO50 ' A3209D060 1114' 117' 80 72 15,7D0 26,700 - A3205PA A3209TL A32129PAF 43209DT050 1l" I 1'l.' 50 45 13,300 I 2,900 A3209DT080 1%" I 1�' I 80 72 15,7DO 26,700 II `3 8 c ^S.$ Enoin—d Contmis Inierm6o-1,Lic100 Rego Dr.P.C.Sox 247 Bon,NC y244 USA w .reioproduds.mn Phone(336)64 TTDT Fes;(336)449�94 }- I ;r, 1 d.. Apphcatfion Designed for Use as a primary relief valve on ASME containers such `i D as 250,50D and 1,000 gallon tanks.Underwriers'Laboratories lists containers systems on which ulese types of valves are mounted } RZA outside the hood without additional protection, ti mounted near the A r hood and fitted with a protective cap_ I; t 1 C..r=-• �- �1 Constructed of non-corrosive materials. - "- "Pop-action"design keeps product lass a`a minimum. - 'r t ASME rated for use with LP-Gas. •Request Regt@ Relief Valves on all your orioina equipmentASMIE Ac3tc➢ials containers for raliable perform;ance_ ----1 Body..._.......__-. »... ._. _ --- ,...., »_. __�_ Brass Spring....-...-----------•----------------•----.•-------------------•-----------•-..... Ste__{ Stem---------------------•---•---•--•-------------------- ----------------- Stainless Steel Seat Disc------------------------.------------------------ ------ Resident Rubber Ordering Information �. 3r-G"��,�ram. ..yam- �,- 3 :IL ::"' t r. '��u,• T`..' r:.0 ems', - _ i`=� 7583G I %' 8�E T'r' 1'/ 1980 1$O6 80 Sa.P� I ,5R34ZX 8684G 250 1' 9%" 19 1 hl1" 2620_ 2565 113 So.-FL j 8684-4Z 8685Gi vw 1,X6 _W 2'/. 1 4385 4035 212 5 .FL 7585-48X ' Per NFPA Pamphlet#58,Appencim U_Araa shown is for UL or ASME fiow rating—whidhews is larger. Application 3'NT Designed especially for use as a primary relief valve on large 3133-11 stationary storage containers,these low pronle relief, valves are generally mounted in half couplings.However,they are designed so Hole that the inlet ports clear the bouom of a full 2'coupling.This assures Deflector that the relief valve should always be capable of maxim Urn flow l under emergency conditions. Wrenchin 3g - A Too of _ in HEDL Coupling Features 2ohA' High capacity,low turbulence design has a maximum guiding area providing a for dependable Shut-off after opening. 2' � T Built-in spring stop pries the rise of the seat in full open position and prevents the spring from going`solid". - NFT Extemal 3" NP t threaded body allows easy attachment of vent stacks- Optional pipeaway adapter has break-0$ groeve to prevent damage to the relief valve should piping be stressed by darrraging winds. Materials t op-Action'design keeps product loss at a minimum. Body•-•------••---••-----•-------•------------------------- ----------------------- Brass No guiding projections around the seat disc retainer to bind and Spring..---------•---•-------•------------------...---•---..—_._---------------_. Steel hinder opening of valve if body is damaged. Stem—-----------------------------— - --------------- Stainless Seel Seat Disc--.__.....------_-----------.___-___-------------._._._ Resilient Rubber Ordering Information _• ,r.f 1 - - ��•11i.� / 11". Ill JI' .- - 7534B J' 125 12 I 6,025 1 - 313 Sq.FL 74G 250 11,675 10,422 708 So.FL 753440 7534 20"` S, 'Fvw rates down are for trace ref valves Adaoi5r and pipeaways w111;duce flow as @sr_vssed in the foreww6mg bfomhzfion_ -Per NFPA Pamphlet 1*5B,Append¢❑..Area shown is for UL or ASWE--whichever is*aroa-. -"•S F.NPT outlet onne:fion, D13 MMULF Engine=_red CordrnL Intamatio al,Im.100 Rego Dr.P.O.Sox 247 Elan,NC=44 USA w xen.oprodui,om Phone(a3E)M4-Tr 07 F=C-36)'-.555w 4 _ . ; r _ 1 V r Hose OPP RDUCTS, INC. High Pressure LPG Hose 350 psi ma)dmum working pressure. UL Listed. 7 132-25354E-350 sized for shipment by UPS. i= Par'no. �!_D- Size O.D. Spir-al/Brid W_/100 7L 9eel Sid Lis` Reel Sze Prime/foot 7132-2MS4 114" 7/B4' 4 spirals 14 Ibs- 7D9 $I.E6 7132 Series 7 1 32-25354E-350 1/ 7/64" 4 spirals 14 lbs. 35a 5 -48 _ 7132-38354 3/E' 3/4' I 4 spirals 22 ms. 550 $2-04 71�-5D354 1/z 15/16, 4 iraL% 301bs- 45C $424 7-M-7-Ea54 3/4' 1 i' 4 spiral 42 ba. 300, r..D4 71 -iDD3S4 1;4' 4 spirals B2 bs. Z59 �5C _ j 72-2-1252 -'/' Ill.' 2 braids 96 It_ 30v 11 B94 7232 Saias - =-1S03 1%z' Z'hc' 3 braids 114 M. 159 $2a.79 7232-20Dr Z 211%' 3 braids 1&2 ibs- 1 SIY $30.12 High Pressure LPG Hose- Stairdess StE--I RArrfDrced Rubber cover. 350 psi maximum working pressure. UL Listed. Cut, lengths-bulk lots 300' to 4-00'. Reel Part no- Size I-D. Size 03. Braid W elgW 00 RRMStandard List 4 - - �II Size Price/Tout 7233 Series c�,; e 7'M7. 11 5119, 43/64' 1 19 lbs. 500' �420 _ 7�1-751 1 3/4' 1IA 1 591hs 109 po-BB 7M1-10D1 1' 11h' 1 1'os 10P W-78 7231.1251 1/' 11W 1 92 lb-- 1W I $48 32 7M-,-15D1 K I W T 1 ':13 lts- 159 S68-B8 { Series 7231-2D0ZK Z' 2m/ee 2 1�It1s 150' $'IC2^4 7231 S .- ^� a ffl- W'Mm High Pressure LPG C:arburetion Hose-Stainless Steel Reinforced Textile braid cover. 350 psi maximum working pressure. UL Listed. Cut lengths-bulk lots 300'to 400'. Part no. Si,--I.D. Si,--MD- Weight'100 m List Pric--a/fnot E0R�FC321-04 /4' 33/6?" 11 Its. $5.44 -Y'FCa21-08 1� 49/64' 211bs $a48 _ I-12 3/4' 1 151W .sr Ibs $18-5D -- Low Pressure General Purpose Hose-Red =yyr'-tom LP-Gas vapor-onty service. Recommended working ressure 125 psi, Rubber coated. L st ?art no. Spirals Sze LD. Size 0-D.Weigh'/i standard 00 Reel SizePice�fooi } - - .ya I 7122-382 2 3/8' 2/32' 149lbs. E5P $236 -- ' fLPG Vapor/Wazer Heater Hose Standard Part no. S¢e I.D. Paclmge I Piers List Prceffoot — - VH 58 5B' - VF�34 3/4' 30' 3 $9-80 VFi-fB 7/5' 30' 3 I M.00 - VH1100 1' 3C 3 IBM VI-L 1 l2 11/2' 30' 3 $10-72 Vacuum Hose Part no. Desorip5on List Prices opt r ti 340-VH Vacxrum hose,3/16' I.D. $1-02 i :! 341--1^r Vacuum hose,1/4'I.D. $-132 !` I 942-VH Vamium hose,3/6"I.D. $CAL Prixs subject to chance wrdmu notce.Some I—may nol be in s'vdc E1 'Rev, 9/200 7 lat all warehouses or—y be speLal order.Plese c�redt w di TCECD. GrIec CTdine:uv%NW.tee=prroducas.com Sacramento, aA Rapid Cttf, SD i Aubur-a,WA e-mail: info@teecoproducts.com (500) 225-6621 (B00) &43�B660 (B00) 42E9456 .� Ii 1 r.� H li ••,s tj� f�l' _'� ;A Pls �� _� _ -II ''� ,1:'I � . � •� A p P iir2faO_5 _ tt 7554S Series valves provide instant shut-on and fast opening control on LP-Gas crop driers. They are also ideal for charging manifold hoses,stationary ffiel transer hoses and other applications requiring quick,positive shut-0fr.They are not for use with delivery truck hoses �• because the handle could snag on the ground and open the valve as the hose is reeled back to the truck. ' 7554L Series valves feature a locking handle device to help prevent , accidental opening of the valve.It is ideal for all the same applications as the 7554S Series and may be used on delwsly trucks as it =. incorporates the locking handle deslgR. Both valve series must be installed so that now through the valve is opposite to tidal of a conventional globe valve.This allows the inlet flow to assist in closing.the valve and prevents the from being 75545 opened-by high pump pressures. I ` -------- � ' 1= 5 ? 3% Quick-acting design speeds transfer operations, permitting rapid; one-handed opening and dosing. / Resilient seat disc provides pos tive shlf-0ff_ iange seal stem design provides for leak-proof operation. No j packing to retigMen or replace. 7554L Series incorporates locking handle to prevent accidental opening of the valve. �-- Vent valve installed on the downstream side of the valve permits =r bleeding of trapped product to assure safe uncoupling. Swivel seat disc minimizes grinding on the body seat and assures = - longer serviG.Fife. '9 Body-------------_--•--------------------------------••--•-----------_-•--- DucSle Iron IBonnet---------.-- - ------------•----•----------------.----------._ Brass W"-Ring-----........................------------------------------------------» _.._.. Teton stem..........._._----.--.---. -----. Stainless Steel 7554LV r B' ----------------••----------------------- Seat Disc--- --------..-...---..._.----__.-_-----------------•-. Synthetic DastDmer ACME Connector--•--.-.-----------_---------------- Aluminum w/Steel Insert Seal Housing................. Stainless Steel O Lever.-•---•-- - -- - - Stainless Steel 3�/ri6 1 ` to / i♦'i{A � ' Y / Inlet R�ip4� Ordariing Information �-3'14t•--t �e— i 5-4SAV No 7.3 75541-AV Yes 7 55,LSV No 113 7-54L5; yes I •7o aotsln app 6niste Bow at othe Ilion 1 PSIG pressure drop,multiply flow in iable by a term WCO of pn=W le drop.E—rnple:7S 4LV 0 4 PSIG=11.5 X I propane. _q Ef IMem.ii—I Inc 100 Reno Dr.P.O.Bo.:247 Son.NC 2724A USA ~w.re?vproduats.=rn Phone(236)"El.-M7 F=(336)44�'4 »: . r I 1 i :� Date: 04/03/2026 Permit#: 1230 Perm Date: 12/07/2016 Review Date: 12/07/2016 Perm Type: COMM IRCIAL MECHANICAL Review Type: COMM 1RCIAL MECHANICAL Target Date: 12/14/2016 Scheduled Time 00:00 Com pleted Date: 12/08/2016 Description: Will require Final Inspection before filling of tank. Review Status: Assigned To: BUILDING Tim eln: 00:00 Time O it: 00:00 H curs: 0.0 Property Information Pl rcel#: 31052200401100 W I LLC WTl LLC 2810 34TH ST 6615 172ND ST NE E VERETT,WA98201 Zoning: 910 Undeveloped (Vacant) LandLot: Block: Permit#: 1230 Permit Date: 12/07/16 Permit Type: COMM IRCIAL M ECHANICAL Project Nam e Washington Trucking Applicant Nam a Associated Petroleum Products Applicant Address: 2320 M 17waukee Way Applicant, City, State, Zip: Tacom 4 WA98421 Contact: Brian Johnson Phone: 253-345-1015 Em al: bjohnson@gotoapp.com Scope of Work: Install 500 gallon propane tank Valuation: 2200.00 Square Feet: 0 Num ber of Stories: 0 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 01/03/2017 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel# Address L egal Description O wner Nam e Caner Phone Zoning 310522GD401100 6 615 172ND ST NE W 1 LLC 910 Undeveloped (Vacant)Land Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License Associated Petroleum Brian Johnson 2 53-627-6179 2320 Milwaukee CONSTRUCTION Products Way CONTRACTOR Plan Reviews Date R eview Type D escription A ssigned To R eview Status 12/07/2016 COMMIRCIAL Will require Final Inspection before filling of tank. B UILDING MECHANICAL Fees Fee D escription N otes A m cant Mechanical Base P erm i Fee $ 25.00 Mechanical Comm ecial Plan Review T able 4-1 $200.00 Total $225.00 Attached Letters Date Letter D escription 12/08/2016 Building Perm i Paym ants Date Paid By D escription P aym ant Type A ccepted By A m amt O1/03/2017 Brian Johnson 6 2936565 c c $225.00 O ttstanding Balance $0.00 Uploaded Files Date File Nam e O1/03/2017 2030630-1230 Issued Permt.pdf 12/07/2016 1999498-1230 Applications.pdf 12/07/2016 1999499-1230 Tank Location.pdf 12/07/2016 1999497-1230 Tank Specs.pdf