HomeMy WebLinkAbout20227 77th Avenue NE_BLD1191_2026 FIRE PROTECTION, INC. PO BOX 12642 MILL CREEK,WA 98082 14251 290-9600 OR 1-800-681-1125 FAX (4251353-4546 October 20,2016 City of ARLINGTON - PLAN REVIEW RE; FIRE ALARM SYSTEM Please find enclosed plans for a FIRE ALARM SYSTEM.The FACP will be located in building 17 ( lower floor of this building is the site community building) , all residential buildings will have their own individual fire alarm annunciator and remote power supply. All residential buildings sprinkler systems will be tied to and monitored by the FACP located in building 17 . The site electricians (Express Electric) are providing building linking conduit/wiring as shown on the included site building linking plan. The SLC and SBUS will be run in a Class A loop as shown. When a Waterflow, Smoke Detector or Pull-station is activated in a residential building, it will annunciate at the annunciator in that specific building and also at the FACP located in building 17 . Residential building occupant notification devices will only activate when an initiating device in that building is triggered, no other building' s occupant notification devices will active. The system has been designed per NFPA 72 , 2013 edition requirements as well as WAC, IBC, IFC 2012 , NEC current and your additional requirements . The building is fully-sprinkled. The system shall monitor by zone activation as well as separate trouble signals . Monitoring shall be provided via UL listed Central Station, The Alarm Center LACEY, WA. Audibility shall be in compliance with NFPA standards . Interior DB shall be 75 DB minimum throughout, (LOW FREQUECNY NOTIFICATION DEVICES TO BE INSTALLED IN RESIDENTAL SLEEPING AREAS . A full service and monitoring agreement is in force for the proper service and maintenance per NFPA requirements . A full pre-test and NFPA form shall be conducted and completed prior to calling the AHJ for acceptance testing. INSTALLATION COMPANY Fire Protection, Inc. 1730 Gibson Rd. Everett, WA 98204 WSCL# FIREPI*021ML UL CERT #608242-002 JOB SITE Park 77 Apartments *Building 15* 20201 77th Ave Ne Arlington , WA APPROVED UL MONITORING COMPANY Alarm Center, Inc. /FPI 4300 3rd Ave. SE Lacey, WA 800-429-0991 UL CERT #902799-02 CONTRACTUAL RESPONSIBLE PARTIES Installation; Monitoring; Service; Testing; Fire Protection, Inc. AMBIENT TEMPERATURES No area with alarm service equipment shall fall below 40 degrees, common areas shall be at 68 degrees per builder AMBIENT NOISE RANGE All areas serviced by the Fire Alarm Control and notification system will be as listed for per UBC listings, per builder. SEQUENCE OF OPERATIONS All Alarm and Trouble conditions shall enunciate at FACP as well as remote notify UL listed Central Station. Zones of alarm shall cause for all notification circuits to activate, send alarm zone to CS, re-dispatch to Fire and dispatch FPI runner service. Trouble and supervisory signals shall transmit to CS which will dispatch FPI runner service to site, (no notification circuits shall activate. ) On site emergency contact personnel shall be notified. Wet Waterflow ALARMS shall be retarded by a period of not more than 45 seconds . Low air shall activate at 25lbs, causing for a supervisory signal . A short on FACP smoke, Waterflow Switches, (wet and dry) and pull station shall cause a alarm. Shorts on PIV, tamper and Hi-low air zones shall cause a Supervisory condition. Opens on any zones shall cause for a trouble signal . Should you have any further questions, please feel free to contact me directly. David Mow VP of Operations/Designer NICET-3 #120904 CITY OF REDMOND D.O.R. #16-B-141 WA JOURNEYMAN LICENSE #MOW**DDE957M6 FACP FOR ALL BUILDINGS LOCATED IN BUILDING 17 @POTTER P 3 00 P/uS Fire Alarm Control Panel Features • 127 expandable to 381 Analog Addressable Points.Any combination of detectors/modules • 5 Amp Power Supply.Expandable to 315 amps • 2 NAC circuits rated at 3 amps maximum,expandable to 188. • 2 Input/Output(1/0)Circuits for system flexibility rated at 1 Amp . �• each _ • Built-in UL Listed IP Communicator • Built-in email event notification and report capability. • Optional Dual Line Digital Alarm Communicator • System wide synchronization of Potter/AMSECO,Gentex, Cooper/Wheelock,and System Sensor signals. • No twisted or shielded wiring required. • Cabinet will accommodate up to 18AH batteries.Panel will charge up to 55AH. • Capable of Class A or Class B wiring configurations • Built-in NFPA 72 compliant smoke detector sensitivity test • Dead-front cabinet design '' �. • 1000 Event History Buffer V` i NYC Fire Dept. Certificate of Approval Potter/Nohmi Protocol Features S735 7165-0328:0195 6156 • Less than 4 second polling time Product includes a 5 year warranty • LED's visible from 360' • Adjustable Smoke Detector Sensitivity • Adjustable Heat Detector Temperature annunciators,intelligent power supplies and other optional modules. • High Temperature Heat Detector as fixed temp The P-Link will support 31 accessories in any combination.The RA- Drift6075 is a 2 x 16 LCD annunciator.The RA-6500 offers a larger 4 x • Compensation 40 line LCD display that allows points and descriptions to be shown • Maintenance Alerts simultaneously.Intelligent remote power supplies repeat the P-Link data • Day/Night Mode and can be mounted 6,500 feet from reach other.P-Link devices such as the RLY-5 relay module,SPG-1000 serial parallel gateway and DRV-50 Description LED driver can be mounted anywhere in the chain of communication with a maximum of 31 of each P-Link devices.A total of two(2) The P300 is a mid-sized analog/addressable fire alarm control panel SLCE-127 Signaling Line Circuit Expanders(loop cards)may be with a total of 381 points.The points may be any combination of smoke installed in the P300 enclosure,in a remote enclosure such as the AE-8 sensors,heat detectors or modules.This panel has a 5 amp power supply or with a PSN-1000E remote intelligent power supply. that is distributed across two Notification Appliance Circuits(NACs) and two Input/Output(1/0)Circuits. The entire system,including the SLC,NACs and P-Link may be converted with a CA-6075 Class A module.The entire system is The NAC circuits are rated at a maximum of 3 Amps each and the 1/0 programmed using a Windows based computer software and requires circuits are rated for a maximum of 1 Amp each.All of the outputs may the use of a software programming software key. be configured for notification or auxiliary power.In addition,each NAC and Output can be programmed for strobe synchronization and utilizes The P300 can communicate to a monitoring station using the on board Quadrasync for strobe synchronization across circuits of various brands. Ethernet connection to an IP communicator or using optional UL listed The 1/0 may also be programmed for a dry contact input such as a water UD-1000 traditional two line alarm communicator.The UD-1000 flow switch or pull station. connects to the main board and has two phone line jacks provided. The IP communicator uses a RJ-45 connection and when connected The cabinet will hold two 12 volt,8 amp/hour batteries or two 12 volt, to the intemet may be programmed to E-mail system status,history 18 amp/hour batteries.The system when fully loaded will charge 55 reports,reminders and the configuration file.The panel may be updated amp/hour batteries.Anything larger than 18 amp/hour will require an remotely using the LTD-1000.If the Ethernet connection is needed external battery cabinet the SSU-00050. remotely,the FCB-1000 fire communication bridge may be installed to The panel has the Potter P-Link connection for expansion with remote allow the Ethernet connection to be installed in a rack. Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • wwpottersignal.com P'�O�IUsJ w. #8830035-REV A PAGE 1 OF 4 08/12 (E) POTT ER P 3 00 Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 381 addressable devices or modules in any combination.The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PSA Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PSHA Combination Analog Photo Electric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135'Fahrenheit heat detector FHA Analog Fixed Temperature Heat Detector that is selectable from 135'F to 185°F RHA Analog Rate or Rise Heat Detector that has a fixed temperature selection from 135°F and 174°F and also will alarm if the temperature increase 12-15°F in one minute DDA Addressable Duct Smoke Detector AB-6 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors AB-4 4"round base that may be mounted to an electrical box and wired for connection to the above sensors AIB Isolater base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop ARB Addressable Relay Base that contains two relays controlled by the SLC.One relay is rated at 8 amps at 240 VAC/30VDC and the other is rated at 2 amps 240 VAC/30 VDC ASB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call. Modules Device Description MCM Miniature Contact Module provides a small foot print contact module for mounting inside an enclosure. APS-SA Single Action Addressable Pull Station APS-DA Dual Action Addressable Pull Station SCM-4 Single Contact Module is a standard contact module with an LED that mounts into a 4"square electrical box. DCM-4 Dual Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. TRM-4 Twin Relay Module provides two form C relays that simultaneously active when the module is triggered by the control panel. Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC. MOM-4 Monitored Output Module is a power switching module that monitors the circuit that is controlled by the control panel. CIZM-4 Conventional Input Zone Module is used to connect conventional smoke detectors to the system that receive their power from the module.This module is like a conventional zone on the SLC. SCI Short Circuit Isolater interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • www.pottersignal.com P"�O�A'SP v #8830035-REV A PAGE 2 OF 4 08/12 (E) POTT ER P 3 00 Fire Alarm Control Panel SLC Features RA-6075—2 x 16 LCD annunciator with a key pad in a locked metal enclosure. The Potter/Nohmi protocol is a digital protocol with a proven design for reliability and noise immunity.The system does not require special RA-6500—4 x 40 LCD annunciator with a key pad in a locked metal cable or conductors for connection of the Signaling Line Circuit as enclosure long as the cable is compliant with NFPA 70 and NFPA 72.The system LED-16—16 LED annunciator with common indicators in a locked allows for Class A or Class B installations as well as"T-Taps." metal enclosure The total polling time for the protocol is about four(4)seconds which PSN-1000(E)—10 amp,remote intelligent power supply with 6 NACs, allows two polling cycles in the ANSUUL 864 requirement of alarms 2 I/Os and a P-Link repeater reporting in less than ten seconds.Each loop is capable of 127 points with the exception of the P100 and P200. CA-6075—Class A convertor that converts the SLC,NACs and P-Link connection Sensor Features UD-1000—UL listed,Dual line telephone alarm communicator The sensors through the fire alarm control panel provide a real DRV-50—LED driver expander,used to connect up to 50 LEDs in a time status as to the condition of the system.The smoke detector graphic display sensitivity,heat detector temperature level and drift compensation FCB-1000—Fire communication bridge,provides remote mounting of as all programmable options.The system also allows for a day/night the Ethernet connection mode where the panel automatically adjusts the sensitivity depending on the time of day.To assist in the reduction of false alarms,the smoke FIB-1000—Fiber interface module,used to extend P-Link to multi- detectors also have a maintenance warning that sends a trouble signal mode fiber(2 required) when a detector is dirty to the point that it can no longer maintain the RLy--5—Relay module,provides 5 form C relay contacts rated at 3.0 programmed sensitivity. amps 24VDC/125AC User Interface SPG-1000—Serial parallel gateway,allows for the connection to a serial or parallel printer The fire alarm control panel has a 4 x 40 LCD display to provide information to the system status.The keypad has navigation keys The FIB-1000,FCB-1000 and the SPG-1000 maybe installed in the t stacker bracket or ordered with the optional rack mount enclosure.o allow manipulation of the Menu on board the panel.The panel is shipped standard with the following LEDs: AE-8—Eight card expansion cabinet • AC Power—Green AE-14—Fourteen card expansion cabinet • Alarm—Red Ethernet/I.P. Connection • Earth Fault—Amber The P300 is shipped standard with an Ethernet connection.This • Supervisory-Amber connection is the programming port and may be connected to a building • Silenced-Amber Wide Area Network(WAN)or Local Area Network(LAN).Once connected to the Internet,the panel may be selectively programmed to • Trouble-Amber e-mail alarm conditions,trouble conditions,supervisory conditions,test, The common buttons include a Silence,Reset,Acknowledge and Drill. Event History and detector status.An e-mail may be sent to the panel All of the buttons are accessible once the locked door is opened. and the panel will e-mail the event history,detector status,configuration file or server status to an authorized E-mail account.In addition, P-Link reminders may be set to send an e-mail for service,testing or other The P300 has a proprietary communication protocol that communicates conditions. through a RS-485 connection to field devices.Up to thirty-one In addition,the Ethernet connection is UL listed as an IP communicator. (31)devices may be connected to a single P-Link connection.The The IP communicator is listed to report to the UL listed Sur-Gard III P-Link includes the communication terminals and regulated 24 VDC IP receiver.The IP communicator replaces the traditional less reliable connection for the field devices.The field devices may be any of the alarm communicator transmitter that utilized telephone lines.The IP following: communicator is an active method of connection and communication to SLCE-127-Analog/Addressable loop expansion module(maximum of 2 the monitoring station. per P300) Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • wwpottersignal.com P'��PlusZ* w. #8830035-REV A PAGE 3 OF 4 08/12 (E) POTT ER P 3 00 Fire Alarm Control Panel Specifications 18.91" 17.60" Electrical Specs:AC Mains O O TOP o 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @ 240 VAC 50/60 HZ 4.41" 3.75" DEPTH Battery p 0 130 mA Standby 220mA Alarm b • 5 Amps power for NACs,I/O and P-Link • 3 Amps per NAC,regulated a • 1 Amp per I/O circuit,regulated �e c7 O • Battery Charger range 8-55 Ah • Battery Charger voltage 27.3 VDC • P-Link maximum current of 1 Amp • Panel holds(2)8AH or(2) 18AH batteries LEFT SIDE RIGHT SIDE Cabinet • 16 gauge cold rolled steel with removable BOTTOM ` locked door • Dimensions—18 15/16"W x 27 5/16"H x 4 7/16"D • Dead front to cover all electronics • Lexan viewing window Temperature and Humidity This fire alarm control is listed and approved for operation in an indoor application with temperature range fluctuations of 32'to 120'(0°C to 49°C) with a maximum humidity of 93%non-condensing.The ideal temperature is 77°F +/- 10°F(25°C+/-5°C). Standards The P300 series fire alarm control panel complies with the following standards and codes. • NFPA 13,70 and 72 • ANSI/UL 864 0 Local(L),Remote Station(RS),Central Station(CS),Propriety(PPU),Auxiliary(AUX) 0 Type of Service:Automatic(A),Manual(M),Water flow(WF)Sprinkler Supervisory(SS) 0 Type of Signaling:Digital Alarm Communicator(DAC),March Time(March),Non Coded(NC),Reverse Polarity(Rev Pol),Other Technologies(OT) • IBC 2000,2003,2006,2009,2012 Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • wwpottersignal.com P'h�T PUF'J w. #8830035-REV A PAGE 4 OF 4 08/12 POTTER RA-6075 The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Features Standby Current 20 mA Alarm Current 25 mA Operating Temperature 0°C-49°C(32°F-120°F) 10%-93% @ 30°C(86°F)non-condensing 0 © humidity Maximum Wire Length 6500 FT ® © Maximum Annunciators 31 - Dimensions(WxHxD) 8"x 6-1/4"x 1-5/8"(Cabinet) Wire Gauge 14 AWG-22 AWG Display 2 lines x 16 characters Product includes 5 year warranty U� LISTED S2930 7165-0328:0195 Description Installation The RA-6075 is a LCD remote annunciator for the PFC-6075 and The RA-6075 is connected to the PFC-6075 using a four wire RS-485 PFC-6030 addressable fire control panel.The RA-6075 communicates connection.The connection is power limited and supervised.Up to using a RS-485 connection to the main panel providing common thirty-one(31)RA-6075 LCD annunciators can be connected using indication of Alarms,Supervisory,Trouble and other system status and Class B or Class A wiring.Class A wiring requires an optional Class A control functions. Expander. The RA-6075 features a 32 character, 16x2 LCD display with LED's for Power,Alarm,Supervisory,Trouble,and Silenced conditions. , It can be mounted on a single gang electrical box or a four square electrical box.The annunciator is enclosed in a sheet metal enclosure Instal!inac!cord!anc!e with compatib7fir,alarm panel. and has a Potter lock securing the keypad. Figure 1:RA-6075 Class B Wiring Example Figure 2:RA-6075 Class A Wiring Example To the next annunciator 4CA-60775 + m + a P-LINK + a + A B + + + + Panel + + + + + + Panel + + Connection Remote -LIN + Annunciator Connection + Remote -LIN< Annunciator m Q m Oa O a + Q O Remote O Remote Annunciator Annunciator Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#5406077-REV B-1 PAGE 1 OF 2 9/11 (E) POTTER RA-6075 The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Address Settings The RA-6075 address is set by dip switch S 1 located on the back of the RA-6075.The address must be set in the range of 1 to 31 to be recognized by the control panel. Figure 3:RA-6075 Class A(back panel view) O ❑ 0 0 OWWWW .-9. O 0 © A on ® 9 ® + Al O o Dip Switch Settings Refer to the table below for dip switch settings per Annunciator Address. Annunciator Dip Switch Settings Annunciator Dip Switch Settings Address SW-1 SW-2 SW-3 SW-4 SW-5 Address SW-1 SW-2 SW-3 SW-4 SW-5 1 On Off Off Off Off 17 On Off Off Off On 2 Off On Off Off Off 18 Off On Off Off On 3 On On Off Off Off 19 On On Off Off On 4 Off Off On Off Off 20 Off Off On Off On 5 On Off On Off Off 21 On Off On Off On 6 Off On On Off Off 22 Off On On Off On 7 On On On Off Off 23 On On On Off On 8 Off Off Off On Off 24 Off Off Off On On 9 On Off Off On Off 25 On Off Off On On 10 Off On Off On Off 26 Off On Off On On 11 On On Off On Off 27 On On Off On On 12 Off Off On On Off 28 Off Off On On On 13 On Off On On Off 29 On Off On On On 14 Off On On On Off 30 Off On On On On 15 On On On On Off 31 On On On On On 16 Off Off Off Off On PRINTED IN USA MFG.#5406077-REV 13-1 PAGE 2 OF 2 9/11 CPOTTER PSN-1000(E) The Symbol of Protection POWER EXPANDER Features 10 Amp Power Supply • 3 Amps,regulated per NAC • 6 NACs Class B or 3 NACs Class A • 2 dry contact inputs • Fully programmable and monitored through control panel _ I Isolated P-Link repeater connection,Class A or B • Up to 31 power supplies per control panel with system wide sync • Quadrasync feature synchronizes strobes from Potter/AMSECO, Gentex,Cooper-Wheelock and System Sensor. ®RPOTTFR PSN-1000 Compatible with all Potter PFC-6000 series fire alarm control panels. Ines➢pool of Frowpon P.—Supply --. Electrical Specs • 120/240 VAC Input at 50/60 HZ • 5.1 Amps/3.0 Amps max draw • Standby Current 60 mA • Alarm Current 200 mA U` S2930 7165-0328: 0195 Product includes a 5 year warranty Description The PSN-1000 series is a UL listed intelligent 10 amp notification power supply and P-Link(RS-485)repeater.The power supply connects to the P-Link bus from the control panel and is operated and supervised from the panel.The power supply may be installed 6,500 feet from the control panel.The PSN-1000 then repeats the P-Link communication for another 6,500 feet. The power supply has six(6)Class B or three(3)Class A power outputs.Each output is regulated and power limited with a 3 Amp maximum rating.In addition,the PSN-1000 has two(2)programmable dry contact inputs.The dry contact inputs are Class B,supervised inputs. The power supply operates on either 120 or 220 VAC power and has a regulated 24 VDC output.In addition,the panel can charge up to 55 AH batteries and will house 18 AH batteries.The cabinet is constructed out of 18 gauge cold rolled steel with a durable red powder coat finish.A standard Potter key lock is provided for securing the door.Electrical conduit knockouts are provided on the sides and top providing installers with multiple options for installing conduits and providing proper power separations. The PSN-1000 is a self contained intelligent power supply/P-Link repeater complete with cabinet.The PSN-1000E is the intelligent power supply/P-Link repeater with additional cabinet room for the exclusive Stacker Bracket for SLCE-127 loop expanders.Both cabinets include space for 18 AH batteries. The power supplies are programmed and controlled through the main control panel P-Link bus.The panel displays any troubles or off normal conditions of the power supply and the events are stored in the panel history buffer. Each output can be independently configured to provide one of four synchronization patterns,constant power,ANSI temporal Code 3 or Door Holder power.The panel can be configured to synchronize Potter/AMSECO®,Gentex®,Cooper Wheelock®and System Sensor®. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830032-REV B PAGE 1 OF 2 09/14 (E) POTTER PSN-1000(E) The Symbol of Protection POWER EXPANDER 18.91" 17.60" 4 0 0 TOP w 0 4.41" 3.75" DEPTH O O 0 0 0 N O O O 0 LEFT SIDE RIGHT SIDE BOTTOM Dimensional drawings showing the cabinet in all three planes. Knock out locations. PRINTED IN USA MFG.#8830032-REV B PAGE 2 OF 2 09/14 4, �� SYSTEM � SENSOR t 41, Photoelectric Smoke Detectors System Sensor i3-series smoke detectors represent significant advancement in conventional detection. 3 The i3 family is founded on three principles:installation TM ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its •Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included with heads).The large wire entry port and in-line terminals provide Large wire entry port ample room for neatly routing the wiring inside the base.The base •In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single-gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,i3 boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock'action. •Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features •Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and •Built-in remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize nuisance alarms.2-wire i3 detectors can generate a remote LED- indicated maintenance and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 •Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i3 •Wide-angle,dual-color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof i3 Loop testing via EZ Walk feature detectors in terms of percent-per-foot obscuration. • •Built-in test switch Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on 2-wire P detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. T istin s M MEA MSFMTPROVED approved approved cC I,us I W6 7272-1653:152 290-01-_ 3C93? (-L3)Smoke Detector Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 1357 (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5 V Maximum:35 V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 NA maximum average;4-wire:50 NA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V Peak Standby Current 2-wire:100 uA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 1207(0°C to 49°C);2WT-B and 4WT-B:327 to 1007(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 1357(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:417(5°C) Sensitivity 2.50/o/ft nominal Input Terminals 14 to 22 AWG Mounting 3'/2-inch octagonal back box 4-inch octagonal back box Single-gang back box flinch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12 V,23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V,23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter f_ SY TE� m2cha system Sensor. �/ 3825 Ohio Avenue•St.Charles, L 60174 Product specifications subjec[to009 System Sensotice.Vsit rystemsensoccom for SENSOR Phone:800-SENSOR2•Fax:630-377-6495 urrentproductinformat5-03180i7-6/09 latest version okhis data sheet. A06-0318-007.6/09•#2169 P POTT ERS A ka-"Wl' DCM-4 ® The Symbol of Protection Dual Contact Module Features • Single module with dual contact monitoring inputs • Two(2)Class B or one(1)Class A monitoring inputs • SLC Class A(Style 6,7)&Class B(Style4) • Mounts in a standard 4"or double gang box s- S. • Wiring terminals accessible when mounted in box ©E�►•■-�+•�.+o • All wiring terminals accept 22 to 14 AWG li wsiar • Product includes a 5 year warranty ee _.. NOTE: This addressable module does not support 2-wire smoke f zz1,1" zi ;, ci detectors. Stock Number: 1430822 LISTED �zw� S2930 7165-0328:0196 Application Technical Specifications The DCM-4 is compatible with Potter's PFC-6000 series and PFC- Operating Voltage 22.0-24.OV 8500 addressable fire alarm control panels.The DCM-4 is an interface Max SLC Standby Current 325 µA module used to monitor dry contact devices such as sprinkler water Aux Power Required 1mA flow,valve tamper switches,or conventional pull stations.The module is capable of monitoring two separate Class B or one Class A circuits. Max Wiring Resistance of IDC I 100 S2 Max Wiring Cpacitance of IDC 1 µF EOL Resistor 5.lK S2 Description Operating Tempurature Range 32 to 120°F(0 to 49°C) The DCM-4 uses two (2) consecutive SLC loop addresses when Operating Humidity Range 0 to 93%(non-condensing) monitoring two(2)Class B circuits or one(1)address when monitoring 127 units(Class A)or 63 units a single class A(Style D)circuit.The module mounts on either a 4" Max no.of Module Per Loop (Class B) square or double gang box.The module is capable of monitoring two (2)separate class B circuits making it ideal for monitoring sprinkler Dimensions 4.17"(106mm)L X 4.17" waterflow and valve tamper switches when they are located in the same (106mm)W X 1.14"(29mm)D proximity.The DCM-4 includes one red LED to indicate the modules Standard 4"Square or status.In normal condition,the LED flashes when the device is being Mounting Options Double Gang Box polled by the control panel.When a contact is activated,the LED will Shipping Weight 0.6 lbs light continuously and in case of an open circuit,the LED will turn off. Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com 8830008-REV B • 7/14 PAGE 1 OF 2 P POTT ERS OHM/® DCM-4 ® The Symbol of Protection Dual Contact Module Setting the Address Each addressable module, smoke sensor,heat detector and combination sensor/detector must be assigned an address prior to installing the device.The address is set using either the hand held device programmer or the addressing feature on the PFC 6000/PFC 8500 Series control panels.When the DCM- 4 is used to monitor two individual Class B circuits a single device address is assigned,with the second address number assigned automatically by the module assuming the next consecutive address.For example,if the first address number is assigned as"2",the second address number will automatically be assigned as SLC device address"3". Before connecting a device to the SLC loop,take the following precautions to prevent potential damage to the panel or device verify the following: 1.Power to the device is removed 2.Field wiring is correctly installed. 3.Field wiring has no open or short circuits. Installation Using Compatible Electrical Box O e ° ° o e Wiring Diagrams DCM-4 With One Class ACircuit NOl FROM FACP OR C 1 PREVIOUS MODULE S+ ZI S- NO2 TO THE NEXT MODULE F 1 C2 SELECT STYLE D 0000 LED Q Z2 NOTE:END-OF-LINE RESISTOR IS NOT REQUIRED DCM-4 With Two Class B Circuits NOl FROM FACP OR C 1 PREVIOUS MODULE S+ Zl "OHM1/2W S- NO2 TO THE NEXT MODULE ppH1pC2 �000 LED O Z2 SELECT STYLE B 5.1K OHM 1/2W Potter Electric Signal Company,LLC St. Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 www.pottersignal.com :so 9001:2008 1 DESIGNING,MANUFACTURING, 8 DISTRIBUTING QUALITY SYSTEMS 8830008-REV B • 7/14 PAGE 2 OF 2 PULL STATION SERIES (E) POTTER DIE-CAST METAL The Symbol of Protection MANUAL PULL STATIONS • UL and cUL Listed,FM Approved,CSFM Listed,MEA ' Approved,ADA Compliant • Single or Dual Action • Terminal connectors PULL UOWN Big . 10 Amp Snap Action Switch Gold plated SPST contacts Optional auxiliary contacts Mounts on standard single gangbox • Surface backboxes available • High-gloss red enamel finish • Glass breakrod DUs FMo �5 Made in the U.S.A. LISTED Description Engineering Specifications The Potter Pull Station Series offers a complete line of die-cast pull The contractor shall furnish and install the Potter series of pull stations for a variety of applications focusing mainly on fire alarm stations as indicated.The pull station shall be die cast construction systems.The pull stations are available in single or dual action with a"T"type pull handle that is ADA compliant.Single action pull models.All of the pull stations have a 10-amp snap action switch and stations shall be a P32-lT.Dual action pull stations shall be the Potter a dedicated terminal block for the ease of wire connections.All of P32-1T-LP.Any manual pull station installed in an outdoor or wet the metal is completely coated to inhibit corrosion and provide for a location shall be a RMS-IT--WP weather proof unit.The contact shall uniform and quality finish. be a single pole,single throw switch rated at 1 amp 30V DC/125V The standard models have a hex key reset,however a key reset is also AC.The device shall have a terminal block for ease of wiring.Once available.The models are available with shallow and deep surface activated,the pull station shall be reset by opening the front cover. mount back boxes and as a weatherproof version. Opening of the cover in a normal state shall initiate an alarm. Operation Specifications The Potter single action series of pull stations operate by pulling Switch Rating: 1 Amp @ 30 VDC the white operating handle straight down and the handle will lock 10 Amps @ 125 VAC into place.The dual action stations require the lifting of the front Pull Station Dimensions: 4-3/4"H x 3-1/4"W x 7/8"D cover and then pulling the white operating handle straight down.The Color:Red with raised white letters,white pull bar with raised red letters stations are reset by opening the front and placing the handle in the For special application manual stations see bulletin#8910014. normal position. For explosion proof manual stations see bulletin#8880014. Ordering Information Type Model Number Stock Number Contact Type P32-1T 1000447 SPST RMS-2T 1000477 DPST Single Action RMS-6T 1000478 DPDT RMS-1 T-KL 1000451 SPST RMS-IT-KO 1000450 SPST,key operated,no pull Weather Proof RMS-1 T-WP 1000401 Dual Action P32-1 T-LP 1000476 SPST Weather Proof Dual Action RMS-IT-WP-LP 1000403 Accessories Notes Dual Action RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1000470 Replacement glass rods(10 per pkg) Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8900097-REV L PAGE 1 OF 1 9/10 PULL STATION SERIES (E) POTTER DIE-CAST METAL The Symbol of Protection MANUAL PULL STATIONS • UL and cUL Listed,FM Approved,CSFM Listed,MEA ' Approved,ADA Compliant • Single or Dual Action • Terminal connectors PULL UOWN Big . 10 Amp Snap Action Switch Gold plated SPST contacts Optional auxiliary contacts Mounts on standard single gangbox • Surface backboxes available • High-gloss red enamel finish • Glass breakrod DUs FMo �5 Made in the U.S.A. LISTED Description Engineering Specifications The Potter Pull Station Series offers a complete line of die-cast pull The contractor shall furnish and install the Potter series of pull stations for a variety of applications focusing mainly on fire alarm stations as indicated.The pull station shall be die cast construction systems.The pull stations are available in single or dual action with a"T"type pull handle that is ADA compliant.Single action pull models.All of the pull stations have a 10-amp snap action switch and stations shall be a P32-lT.Dual action pull stations shall be the Potter a dedicated terminal block for the ease of wire connections.All of P32-1T-LP.Any manual pull station installed in an outdoor or wet the metal is completely coated to inhibit corrosion and provide for a location shall be a RMS-IT--WP weather proof unit.The contact shall uniform and quality finish. be a single pole,single throw switch rated at 1 amp 30V DC/125V The standard models have a hex key reset,however a key reset is also AC.The device shall have a terminal block for ease of wiring.Once available.The models are available with shallow and deep surface activated,the pull station shall be reset by opening the front cover. mount back boxes and as a weatherproof version. Opening of the cover in a normal state shall initiate an alarm. Operation Specifications The Potter single action series of pull stations operate by pulling Switch Rating: 1 Amp @ 30 VDC the white operating handle straight down and the handle will lock 10 Amps @ 125 VAC into place.The dual action stations require the lifting of the front Pull Station Dimensions: 4-3/4"H x 3-1/4"W x 7/8"D cover and then pulling the white operating handle straight down.The Color:Red with raised white letters,white pull bar with raised red letters stations are reset by opening the front and placing the handle in the For special application manual stations see bulletin#8910014. normal position. For explosion proof manual stations see bulletin#8880014. Ordering Information Type Model Number Stock Number Contact Type P32-1T 1000447 SPST RMS-2T 1000477 DPST Single Action RMS-6T 1000478 DPDT RMS-1 T-KL 1000451 SPST RMS-IT-KO 1000450 SPST,key operated,no pull Weather Proof RMS-1 T-WP 1000401 Dual Action P32-1 T-LP 1000476 SPST Weather Proof Dual Action RMS-IT-WP-LP 1000403 Accessories Notes Dual Action RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1000470 Replacement glass rods(10 per pkg) Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8900097-REV L PAGE 1 OF 1 9/10 GENTEX CORPORATION Low Frequency Audible Signal GHLF Applications 24 V D C The GHLF is a high quality, low profile, low frequency audible appliance that offers a dependable audible alarm with a low current draw. The GHLF is ideal for any S E R I E S occupancy that requires notification appliances. The GHLF horn offers a 520 Hz square wave,temporal 3 tone. A jumper selection is available for normal or loud decibel tone. A temporal 4 pattern is available when used with the Gentex GTSM Synchronization Control Module. The GHLF is shipped with a standard 4" metal mounting plate which incorporates the popular Super-Slide°feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The GHLF also features the patented Checkmate°- Instant Voltage Verification feature which allows the installer to check the voltage drop and match it to the blueprint. The GHLF horn is listed to ANSI/UL 464 and CAN/ULC S525, is listed for use with fire Product Listings protective systems and is warranted for three years from date of purchase. SIGNALING Standard Features � • Nominal voltage 24 VDC • Input terminals accept 12 to 18 AWG C&uS :U0= O Unit Dimensions:6-1/8"(15.55 cm)high x • Produces a 520Hz square wave,temporal 3 LISTED 5-1/2"(13.97 cm)wide x 1-5/8"(4.13 cm) tone deep • Jumper selection for normal or loud dBA • ANSI/UL 464 Listed • Super-Slide®Bracket-Ease of Supervision • Temporal 4 pattern available when used • CAN/ULC S525 Listed Testing with Gentex GTSM Synchronization Module • CSFM: Pending • Checkmate°-Instant Voltage Verification • Temporal 4 520Hz measured per Product Compliance • Synchronize horn with Gentex GTSM ANSI/UL 2075 • NFPA 72 Synchronization Control Module • Tamperproof re-entrant style grill and • IBC/IFC/IRC • Prewire entire system,install mounting locking screw(optional use) • Quality Management System bracket,then install signals • Faceplate available in red or off-white is certified to:ISO 9001:2008 Model Number Part Number Nominal Voltage Model Designations: �i •j ' = R=Red Faceplate MEMBER •� GHLFW 904-0530-002 24 VDC W=White Faceplate ASSEMBLED IN GHLFR 904-0531-002 24 VDC All units are plain(no lettering) THE USA Horn Decibel Levels: 24VDC Nominal Horn Horn Current Ratings Reverberant Room Current Ratings(mA) Over Input Voltage Range of 16-33V(mA) Minimum SPL Minimum SPL 24VDC 24VDC 24VFWR 24VFWR Regulated Regulated Regulated Regulated at 10Ft.Per at 10Ft.Per Operating Operating Operating Operating 24VDC Max. 24VDC Max. 24VFWR Max. 24VFWR Max. Horn Mode Operating Operating Operating Operating ANSI/UL 464 ANSI/UL 464 Current Current Current Current Current Current Current Current (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) Temporal 3 520 Hz I 77.8 dBA 1 79.8 dBA 72.1 mA 120.1 mA 104.6 mA 158.4 mA 99.4 mA 155.8 mA 152.1 mA 213.5 mA Temporal 4 520 Hz*1 81.5 dBA 1 83.4 dBA 75.9 mA 116.0 mA 108.1 mA 182.0 mA 100.1 mA 157.2 mA 163.1 mA 235.2 mA O Temporal 4 520 Hz measured per ANSI/UL 2075 NOTES: • Operating temperature:32 to 120 F(0 to 49 C).The GHLF is not listed for outdoor use. • For nominal and peak current across ANSUUL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. RMS current ratings are per ANSUUL average RMS method. ANSUUL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units). For unfiltered FWR ratings,see installation manual. GHLF 24 VDC S E R I E NOTES: UL Listed • THIS APPLIANCE IS NOT RECOMMENDED FOR USE ON CODED OR Control Signal Signal PULSING SIGNALING CIRCUITS Panel S+ s- s- H+ H- S+ s+ s- H+ H- • THE FOUR PULSE TEMPORAL PATTERN(TEMPORAL 4)CAN ONLY BE Supervised 0 0 0 0 OBTAINED ON THIS PRODUCT WHEN USED IN CONJUNCTION WITH Signal Circuit THE GENTEX GTSM SYNCHRONIZATION MODULE 1 + ENO LINE • SEE GTSM CONTROL MODULE MANUAL(550-0632,MANUAL ISSUE RESISTOR DATE(02-01-15)FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. S GTSM MANUAL CAN BE OBTAINED AT WWW.GENTEX.COM/FIRE OR CALL GENTEX CORPORATION AT 1-800-436-8391. DOIMIW x o Lt LOCKING 0 0 o SCREW 0 " (optional) Cho H+ logo RED WIRES �- H! Q BLACK WIRES 6- � O o H- U a O o 00 NORMAL-LOUD o c �`f/ DECIBEL JUMPER. 0 0 FOR LOUD DECIBEL CEED INSTALL JUMPER. SLIDE ONTO BRACK Gentex Checkmate® Gentex Super-Slide® LOCKING Instant Voltage Verification: Mounting Bracket: SCREW It is often necessary to confirm the voltage drop Allows the installer to pre wire the system, (optional) along a line of devices.The access holes are test for system supervision,remove the provided in the back of the terminal block to signal head until occupancy,switch out allow the voltage to be measured directly without Gentex signals without changing removing the device.Typically this would be done mounting brackets and has locking edge at the end of the line to confirm design criteria. connector for snap-in-place installation. Most measurements will be taken using the S+ and S-locations although access is provided to other locations. NOTICE:CARE SHOULD BE TAKEN TO NOT qM SHORT THE TEST PROBES. Architect & Engineering Specifications The alarm horns shall be Gentex model GHLF.The appliance shall be listed with Underwriters Laboratories(ANSI/UL)for use with fire protective signaling systems (ANSI/UL 464) and with CAN/ULC S525 with intended use in fire alarm systems. The GHLF will produce a peak sound output of 88.3 dBA as measured in an anechoic chamber. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power at 24 VDC. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton Important Notice: GHLF-01 GENTEX These materials have been prepared Gentex Corporation Gentex')for informational purposes only,are O necessarily summary,and are not purported to serve as legall advice and should not used s such. Gentex makes no representations and warranties,express or implied,that these materials are complete and CORPORATION accurate,up-to-date,or in compliance with all relevant local,state and federal laws,regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to Fire Protection Products Group•www.gentex.com particular fact patterns.Each persons activities can differently affect the obligations that exist under applicable laws,regulations or rules.Therefore,these materials should be used only for informational 10985 Chicago Drive •Zeeland, Michigan 49464 purposes and should not be used as a substitute for seeking professional legal advice.Gentex will not be 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. CPOTTER MHT 1224 SERIES The Symbol of Protection LOW CURRENT MINI-HORN Features • Single unit is capable of 12 or 24 VDC determined by the input I voltage - Y I I IEI I Unit Dimensions:4.48"(11.38cm)high x 2.84"(7.21 cm)wide x F I 0.5"(1.27 cm)deep Jumper selectable temporal 3 or continuous tone I I I i Horn frequency is 3100Hz I I I I Terminal blocks(12 AWG to 18 AWG) • Low current consumption • Variety of mounting options for new construction and retrofit E applications • Synchronize using the AVSM Series control module • ANSUUL 464 listed for fire protective service • Textured finish high impact plastic faceplate,available in red or off-white Ordering Information Operating Temperature(indoor use only) Stock Number Model Number Model Designations 320 to 120OF(00 to 49°C) 4890001 MHT-1224R R=Red facepalte 4890002 MHT-1224W W=Off-White faceplate 4890003 MHT-1224PR P=Plain 4890004 MHT-1224PW SIGNALING U� LISTED Product includes a 5 year warranty Description The MHT-1224 Series mini-horn is a high quality remote The MHT-1224 can be used on the same sync circuit(AVSM audible signaling appliance that offers dependable remote annunciation. Series Control Module)as other Potter signals.The MHT-1224 Series The MHT-1224 is ideal for applications where a dependable audible is ANSUUL 464 listed for use with fire protective systems. alarm signal is required in applications such as hotels, dormitories, and apartments.The MHT-1224 is listed for use with both filtered and unfiltered power and a jumper is provided to select either temporal 3 or continuous tone. Architect&Engineering Specifactions The alarm horns shall be Potter model MHT-1224.The appliance shall be listed with Underwriters Laboratories(ANSUUL)for use with fire protective signaling systems(ANSUUL 464)and produce a peak sound output of 90dBA or greater as measured in an anechoic chamber.The appliance shall be of solid-state construction and be polarized to operate from 8-33VDC with a 22mA current drain at 24VDC.The appliance shall be provided with 2 terminals,and mount to a variety of single-gang back boxes. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830065-REV A PAGE 1 OF 2 06/13 (E) POTTER MHT 1224 SERIES ® The Symbol of Protection LOW CURRENT MINI-HORN Mini-Horn Wiring UL MHT-1221 MHT-I I 1151I I; WIRING DIAGRAM FOR DUAL CLASS B CIRCUITS WITH A SINGLE AVS"CONTROL MODULE CONTROI PANtI + — + SYNCODULAl10N F A C P MUrAIIE 1MT•t7H ANT•t!N h• lu M SIJI>f kV F.I 'NU IT I INr SIGnn•. tE51STDR CIRI'I ' EOI R SIGNAL CIRCUITS wr-Tti+ rrtfar 1_4Cf< B:-ALK Et,-ACK BLAf,R a., Wiring Diagram EOLR Mini-Horn Wiring Use a screwdriver to break the jumper for a continuous tone. O DO NOT BREAK m JUMPER IF TEMPORAL 3 TONE IS NEEDED. Horn Mode Minimum SPL at 10 Minimum SPL at 10 Reverberant dBA at 10 In Anechoic MHT-1224 Current Ratings feet per ANSI/UL feet per ANSFUL feet per ANSI/UL 464 Room dBA @ I 24 VDC 22 mA 464 at 24 VDC 464 at 12 VDC 10 ft. 24 VDC UL Max 18 mA Temporal 3 81 dBA 78 dBA 78-86 90 12 VDC UL Max 13 mA Continuous 86 dBA 1 83 dBA 78-86 90 NOTES:The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. 1 RMS current ratings are per ANSFUL average RMS method.ANSFUL max current is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units)(8-17 VDC for 12 VDC units).For strobes,the ANSFUL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units)(8 VDC for 12 VDC units).For audibles,the max current is usually at the maximum listed voltage.For unfiltered FAIR ratings,see installation manual. PRINTED IN USA MFG.#8830065-REV A PAGE 2 OF 2 06/13 GENTEX CORPORATION GOE OUTDOOR ENCLOSURE Applications A C C E S S O R I E S The Gentex GOE Outdoor Enclosure is ANSI/UL 464 listed for use in indoor and P A G E outdoor applications when used with the Gentex GEH Series horn and WGE Series strobe and horn/strobe. Standard Features • ANSI/UL 464 listed • Back box with side mount tabs • Made of clear Lexan°- providing maximum visibility and reliability • Unit Dimensions: 5.75" (14.61 cm) high x 4.75" (12.10 cm)wide x l •�,''- 4.18" (10.62 cm) deep • 3/4"conduit knockouts l'llll� • Reinforcement steel hardware --- R • Outdoor resistant gasket • Available in red or off-white GOE-R GOE-W GOELP OUTDOOR ENCLOSURE Applications The Gentex GOELP Low Profile Outdoor Enclosure that creates a surface mount look, is ANSI/UL 464 listed for use in indoor and outdoor applications when used with the Gentex GEH Series horn and WGE Series strobe and horn/strobe. Standard Features • ANSI/UL 464 listed • Back box with outdoor resistant seal for mounting to wall GOELP GOE • Made of clear Lexan°- providing maximum visibility and reliability • Unit Dimensions: 5.75" (14.61 cm) high x 4.75" (12.10 cm)wide x 3.25" (8.255 �+- cm) deep • 3/4"conduit knockouts • Reinforcement steel hardware • Outdoor resistant gasket • Available in red or off-white GOE AND GOELP NOTES: • Product does not meet ANSI/UL 1971 light distribution requirements • To allow for drainage, the seal on the bottom edge is not water tight GOELP-R GOELP-W GBLP OUTDOOR BACK BOX Applications f ►'� The Gentex GBLP Outdoor Back Box is constructed of durable plastic is ANSI/UL _ •, 464 listed for use indoor and outdoor applications when used with the WSSPK Series speaker and speaker/strobe. Gl Standard Features o' v • ANSI/UL 464 listed ,.. • 1/2"conduit knockouts with metal washer reinforcements i • Wiremold knockouts for 500, 700 Series and pendulum mount • Unit Dimensions: 6.20" (15.75 cm) square x 2.04" (5.18 cm) deep • Reinforcement steel hardware GBLP-R GBLP-W • Outdoor resistant gasket • Available in red or off-white ACCESSORIES PAGE GSB SURFACE BACK BOX Applications The Gentex GSB Surface Back Box is constructed of durable plastic and is fully compatible with the Commander' (GE)and Commander'(GE3) Series horns, strobes and horn/strobes. Standard Features • ANSI/UL listed for indoor use • 1/2" conduit knockouts with metal washer reinforcement • Wiremold knockouts for 500 and 700 Series • Unit Dimensions: 5.57" (14.15 cm) high x 4.55" (11.56 cm) wide x 1.47" (3.73 cm) deep • Screw heads hidden GSB-R • Available in red or off-white ALERT & AGENT BEZELS Applications The Gentex ALERT and AGENT bezels are constructed of durable plastic and is q fully compatible with the Commander (GE)and Commander' (GE3) Series horns, l strobes and horn/strobes. E Standard Features R T • Easy to install I • ALERT or AGENT wording on both sides of bezel • Available in red or off-white ALERT-W AGENT-R GCSB CEILING SURFACE BACK BOX Applications The Gentex GCSB Surface Back Box is constructed of durable plastic and is fully compatible with the Commander (GC) Series strobes and horn/strobes. Standard Features • ANSI/UL listed for indoor use • 1/2"conduit knockouts with metal washer reinforcement • Wiremold knockouts for 500, 700 Series and pendulum mount • Unit Dimensions: 6.2" (15.75 cm) round x 1.67" (4.24 cm) deep • Screw heads hidden • Available in red or off-white GCSB-R GCSB-W Important Notice: 551-0031-02 G E N T E X These materials have been prepared Gentex Corporation("Gentex")for informational purposes only,are necessarily summary,and arere not purported to servee as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these materials are complete and accurate,up-to-date,or in compliance with all relevant local,state and federal laws, CORPORATION regulations and rules. The materials do not address all legal considerations as there is inevitable Fire Protection Products Group•www.gentex.com uncertainty regarding interpretation of laws,regulations and rules and the application of such laws, regulations and rules to particular fact patterns. Each person's activities can differently affect the 10985 Chicago Drive •Zeeland, Michigan 49464 obligations that exist under applicable laws,regulations or rules. Therefore,these materials should be used only for informational purposes and should not be used as a substitute for seeking professional 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax legal advice. Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. S-24 & HS-24 CPOTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Features • 24VDC units have field selectable candela options of 15,30,60, 75,& 110 • Super-Slide®Bracket-Ease of Supervision Testing • Checkmate®-Instant Voltage Verification • Synchronize strobe and/or horn with AVSM Control Module • Prewire entire system,install mounting bracket,then install - signals f, _ — Documented lower installation and operating costs Input terminals accept 12 to 18 AWG Switch selection for high or low dBA Switch for chime,whoop,mechanical and 2400Hz tone Tamperproof re-entrant style grill R I I I I I I I I Switch for continuous or temporal 3 tone(not available on whoop tone) • Surface mount with the AVBB(Surface Mount Back Box) • Silence audible while visual appliance will remain flashing(for use in accepted jurisdictions) • Faceplate available in red or off-white Operating Temperature • 320F to 120OF(0°C to 49°C).The HS and S Series are not listed for outdoor use. Unit Dimensions • 5"(12.7 cm)high x 4.5"(11.43 cm)wide x 2.5"(6.35 cm)deep U� LISTED S3247 Description The S-24/HS-24 Series is a low profile strobe and horn/strobe This Series is shipped with a standard 4" metal mounting combination that offers dependable audible and visual alarms and the plate which incorporates the popular Super-Slide®feature that allows absolute lowest current available. the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without The S-24 & HS-24 Series 24VDC offers tamperproof field any screws showing. selectable candela options of 15,30,60,75,and 110 candela. The S-24/HS-24 also features the patented Checkmate® - The Strobe and Horn/Strobe offers a continuous or sync Instant Voltage Verification feature which allows the installer to check temporal three in 2400Hz and mechanical tone, a chime and whoop the voltage drop draw and match it to the blueprint. tone.All tones are easy for the professional to change in the field by the use of switches. The S-24&HS-24 Series appliances are ANSI/UL 464 and ANSI/TJL 1971, listed for use with fire protective systems and are The S-24 & HS-24 Series has a minimal operating current warranted for three years from date of purchase. and has a minimum flash rate of 1 Hz regardless of input voltage. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 1 OF 4 06/13 S-24 & HS-24 (E) POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Tone Switch Locations TONE SWITCH POSITION 3 4 5 ®o Mechanical Temporal 3 ON ON ON �® 1, Mechanical-Continuous OFF ON ON 2400Hz-Temporal 3 ON OFF ON ® S+ 2400Hz-Continuous OFF OFF ON S- Chime-Temporal 3 ON ON OFF -® H+ � Chime-Continuous I OFF ON OFF Whoop I ON OFF OFF Whoop OFF OFF OFF NOTE: • Switch Positions 1 and 2 in the OFF position to select isolated horn and strobe power inputs • Switch Position 6 ON=HIGH dBA • Switch Position 6 OFF=LOW dBA Super Slide®Mounting Bracket Checkmate®Instant Allows the installer to pre-wire Voltage Verification the system,test for system It is often necessary to confirm the voltage supervision,remove the signal drop along a line of devices.The access head until occupancy,switch holes are provided in the back of the out signals without terminal block to allow the voltage to be changing mounting brackets measured directly without removing the and has locking edge connector device.Typically,this would be done at the for snap-in-place installation. end of line to confirm design criteria.Most - measurements will be taken using the S+ and S-locations althouhg access is provided to other locations. NOTE:Care should be taken to not short the test probes. Candela selection slider switch. Depress center and slide switch to desire brightness level. r- T Break off pin and insert l S into hole at the bottom of .a the selector to lock candela setting.Signal must be removed from bracket and pin pushed forward from backside out of hole to change candela. To remove bezel,grip both sides of bezel and pull in a download and outward motion. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 2 OF 4 06/13 S-24 & HS-24 CF POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES S-24 24 VDC Selectable Candela,Low Profile Evacuation Strobe Model Part Nominal Candela Number Number Voltage (ANSI/UL 1971) S-24WR I 4890010 24 VDC 15,30,60,75, 110 S-24WW 4890011 24 VDC 15,30,60,75, 110 HS-24 24 VDC Selectable Candela,Low Profile Evacuation Horn/Strobe Model Part Nominal Candela Reverberant dBA at In Anechoic Room Number Number Voltage (ANSFUL 1971) 10 ft.,per ANSI/UL 464 dBA at 10 ft. HS-24WR 4890030 24 VDC 15,30,60,75, 110 62-82 100 HS-24WW 4890031 24 VDC 15,30,60,75, 110 62-82 100 S-24&HS-24 Product Strobe Current Ratings(mA) 24 VDC(16-33 Volts) Model Designations: W=Wall Mount Candela 24 VDC UL Maxi R=Red Faceplate W=White Faceplate 15 cd 30 mA 42 mA 30 cd 35 mA 58 mA All units are available in plain(no lettering). Plain units are non-returnable. 60 cd 66 mA 97 mA 75 cd 80 mA 116 mA ALERT bezel available for order. 110 cd 103 mA 161 mA ALERT bezel available for order. S-24&HS-24 Product Horn Current Ratings Horn Decibel Levels Horn Current Ratings Minimum SPL Minimum SPL Regulated 24 VDC Horn Mode at 10 ft.,per at 10 ft.,per Max.Operating @ ANSI/UL 464 ANSI/UL 464 High Setting(mA) (HIGH) (LOW) Temp 3 2400 Hz 78 dBA 71*dBA 28 mA Temp 3 Mechanical 76 dBA 70*dBA 25 mA Temp 3 Chime 70*dBA 66*dBA 15 mA Continuous 2400 Hz 81 dBA 74*dBA 28 mA Continuous Mechanical 80 dBA 72*dBA 25 mA Continuous Chime 70*dBA 66*dBA 15 mA Whoop 82 dBA 69*dBA 56 mA NOTES: • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified]) power,see installation manual. • Potter does nto recommend usign a coded or pulsing signaling circuit with any of our strobe products. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service.These settings are acceptable only for private mode fire alarm use.Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 3 OF 4 06/13 S-24 & HS-24 (E) POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Architect&Engineering Specifications The audible and/or visible signal shall be Potter S-24 strobe and Potter HS-24 horn/strobe Series or approved equal and shall be listed by Underwriters Laboratories,Inc.per ANSI/UL 1971 and/or ANSI/UL 464.The notification appliance shall also be listed with Factory Mutual Listing Service(FM)and the California State Fire Marshal(CSFM). The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater at 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage.The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control Control Panel signal signal Panel Signal Signal g+ S+ S- H+ H- S+ S+ S- H+ H- s+ S+ S- H+ H- S+ S+ S- H+ H. Supervised Supervised 0 B 0 B Signal Circuit Signal Circuit \ + \ + END LINE END OF LINE RESISTOR RESISTOR \ + 7D END OF LINE RESISTOR NOTES: • All strobes are designed to flash as specified with continuous applied voltage.Strobes should not be used on coded or pulsing signaling circuits.However,use of the Potter AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe,horn,and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION,REFERENCE AVSM CONTROL MODULE DATA SHEET(8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS.AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 4 OF 4 06/13 9 8 7 6 5 4 3 2FIRE PROTECT70N INC. 1 DEVICE INSTALLATION REQUIREMENTS PARK 77 APARTMENTSVICINITY MAP 1730 Gibson Road Everett,WA.98204 trvu awnr 425-290-9600800 CEILING MOUN NOT PERMITTED SMOKE/HEATJ+ Y(MINI) CEILING) HRE DAVID MOW DETECTOR �' AUDIO/VISUAL L�y E T B VISUAL DEVICES L A• 1OT H RE RM H� MAX _ 120904, HERE LEVEL III BUILDING 15 a.....wno�...ew.wo�un�a yafewav PERMITTED, D PALR P➢tE RBE we rlox HERE McDonalcr ��H„B n°mER NFPA no D e e 6w PFlD]E V W6 FIRE ALARM = A' fAr� %SNH 7YM —�r 000805173 0 f.6'D 2SR yM{ f6'AR 6PAa 64'An FIRE �NANUAL O v_ ROY L CATS tx n6t 71M PRONE PULL Aerospace Avenue NattAott Q�QPOTECjjOy JACK STATION nufactunng Tech FlNISHEII FLOOA 48-MAX ARLINGTON' WA y NFPA' y^' CFPS #1473 INSTALLATION NOTES CITY OF REDMOND DAaVIIDD MO W Fire Alarm Symbol Legend as#16-B-141cc° SYMBOL 1) Prior to calling for inspection,the installer shall provide DESCRIPTION PART NUMBER MFG CITY BACKBOX REQUIREMENTS MOUNTING REQUIREMENTS 204TH STREET N.E. documentation to the local AHJ stating that the system has been ® LCD REMOTE ANNUNCIATOR RA£075 POTTER 1 installed,tested,evaluated and confirmed to be in accordance with all ® DUAL INPUT CONTACT MODULE DCM4 POTTER 1 BBOX4,Standard backbox,4 °w governing codes and the approved plans.The Fire Alarm System - -'� AREA OF WORK C IJ PULL STATION SINGLE ACTION P31-1T POTTER 1 BBOX-2,Standard backbox,2 48'AFF = H n installer shall complete an NFPA72 Record of Completion(NFPA72 n W�s� 10.18.2.1.1). The completed Record of Completion shall be provided to SPRINKLER TAMPER BY OTHERS BY OTHERS BUILDING 15 U u m n C the AHJ inspector at the time of inspection(NFPA72 10.18.2.1.2.4). WATERFLOW BY OTHERS BVOTHERS BLDG.13 =/ i- -T} Z oc Q s - -•> o°O K 2) Instructions for the operating,testing and maintenance of the !,S) SMOKE,PHOTO.2-WIRE 2W-B SYS SENSOR 1 BBOX-2,Standard baclmox,2 o W N Q system,along with record drawings otherwise referred to as > a o a- ® SITE FACP LOCATED IN BUDDING 17 P300 POTTER E BLDG.12 o 1 ¢ >w w ("as-built")and equipment specifications shall be provided at an DID z z o approved location(NFPA72 10.18.2.3). 0 MINI HORN, MHT-1224W POTTER 12 BBOX-2, 2 STAFF BLDG.11 >IMpu ti m C w w r BLDG.14,' 3 p w�1 W a LF HORN LOW FREQUENCY,WH GENTEX GHLFW 23 BBOX-4,Standard backbox,4 82'AFF a,Q O 3) All systems and devices shall be installed and tested per the �" t w w c E manufactures listing and the authority having jurisdiction(NFPA72 ------- 3 c v a w 10.14.2.1).Label all device locations containing EOL resistors. Ps I INTELLIGENT IOAMP REMOTE POWER EXPANDER PSN-1000 POTTER 1 T I BLDG.17 y REVISION RECORD HORN/STROBE,2 WIRE,M-C,RED,WALL HS-24WR POTTER 1 BBOX-2,Standard backbox.2 82'AFF I Community _+ccu /� _ °' DATE/DESCRIPTION 4)FACP&all Remote Power Supplies REQUIRE a DEDICATED 120VAC Building, BLDG.9 20amp circuit.A notice placed in the FACP shall direct personnel to the OUTDOOR HORNISTROBE WEATHERPROOF ENCLOSURE GOELP POTTER i I L BLDG.10 �- - - location of the electrical panel that is supplying DEDICATED power to the system(NFPA72,Section 10.5.5.1). The DEDICATED circuit breaker I ;BLDG.8 that serves the fire alarm system shall be Labeled and Secured against BLDG.16 I d SHEET LIST J --. tampering with a RED breaker lockout(NFPA72,Section 10-5.5.2). I - FA 0.0 FA DETAILS -, '-BLDG.6 rBLDG.7_ 5 This property will have one FACP located in the Community Building. = BLDG.5- I. FA 1.0 FIRE ALARM P P T'tY Y 9• @ I __y _ -I) FA 2.0 RISER/CALCS --_ Each residential building will have a Remote Power Supply and a - --- ----- _- B Remote Fire Alarm Annunciator connected to the main FACP in the - Community Building.The FACP will monitor each buildings fire IN op - B sprinkler system via SLC,the occupant notification devices in each no no BLDG.1 a the building will only activated when a fire alarm device from that J specific building(waterflow,smoke detector,pull-station) is activated. -BLDG®2 BLDG.3 BLDG 4 6) Wall mounted strobes shall be placed 80"minimum to 96"maximum above floor level.(NFPA72 18.5.4.1&2).Wall mounted strobes shall be SITE PHASING PLAN sized in accordance with(NFPA72 Table 18.5.4.3.1(a).Ceiling mounted SYSTEM OUTPUTS strobes shall be placed and sized in accordance with(NFPA72 Table Required Fire Safety Control 18.5.4.3.1(b). Control Unit Annunciation cO1 / - 7) When MORE than two notification appliances are visible at the same .r``f� a° ;' SCALE: 1/8"=1' time whether they are in the same room or adjacent space within the y a °Q` field of view,the flash of those strobes shall be synchronized(NFPA72, ,.sue:`y y.�° ` DATE: 10/10/16 .n�2¢m c.e cm Section 18.5.4.3.2(3)&(4). °,y �d`"'$�� PROJECT NAME w.o> e m 7 a Q•O 8) Pull stations shall be placed between 42 and 48 inches above floor °zko o o°y a' CIRCUIT LINE TYPE Circuit Legend level.Devices shall be red in color ICC A117.1 309&NFPA 72 17.14.5 . ° y W Abbreviation Type Name ( ) F 4 f y C O P m ��'y ua �y o c u U #18/4 FPLR SLC-SIGNAL LINE CRKT Z Z Q 9) Outdoor strobes required for approaching Emergency Vehicles to a a a Q F� d,°,3 ----- W LO be located in the upper 25%of the building(at a serviceable height), ;4 y 3 9 A A #16/4 FPLR TWISTED PAIR NAC-NOTIFICATION CRKT UJ and to be clear) visible from the emergency vehicle approach path. d °F e F e> B B #18/4 FPLR SBUS I-- CD Q Z Y 9 Y PP P A A Z O 10 SYSTEM INPUTS Fire Alarm circuits to be installed/secured/terminated in accordance D EF~G QHI oJ ~ /� B C with NEC,NFPA 72,IFC and Local AHJ requirements&standards. 1 Manual Fire Alarm Boxes ♦ ♦ ♦ ♦♦ 1 Q 0 1-:3 2 Smoke Detectors ♦ ♦ ♦ ♦♦ 2 n :3 0 J 11)The means of communication to the central stations for the fire 3 W Sprinkler ♦ ♦ ♦♦♦♦ 3 Fire Alarm Device Numbering Y cV IX 4 Sprinkler Control Valve ♦ - ♦ - 4 N Q alarms stem is to be provided b a Potter UD-1000 DACT as per Ian. Q y P y P P 5 Fire Alarm AC Power Failure ♦ - ♦ 5 (SLC)ADDRESSABLE DEVICES NOTIFICATION DEVICES System requires 2 x POTS telephone lines,1 of these lines is required 6 Fire Alarm System Low Battery ♦ ♦ 6 d to be DEDICATED to the FACP.The FACP is located in building 17. 7 Open Circuit ♦ ♦ 7 CIRCUIT CIRCUIT 8 Ground Fault ♦ ♦ 8 F �DEVICEADDRESS DEVICE 12)All building linking conduit&wiring to be provided/installed by 9 Notification Appliance pliance Circuit Short ♦ ♦ 9 ` CANDELA— ' SHEET DESCRIPTION (S) 10 Remote Pow sLc•#x# Power Supply Trouble - - ♦ ♦ - 10 ` l others. a a c D E F G H I J FIRE ALARM OPERATIONAL MATRIX SIG#•### ##CD SMOKE DETECTOR SHOWN AS EXAMPLE DETAILS SHEET NUMBER FA 0.0 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 FIRE PROTECTION INC. 1730 Gibson Road Everett,WA.98204 425-290-9600 DAVID MOW m _ _, 120904 - - LEVEL III D UO.11 n1 NR UNITD-9 UNIT 0.10 r--- 3 I D slca•aoe I B/{FPLR H UWD-12 IN THE RIBERROOM.. NFpA rI- 000805173 I �❑ ROY L CATS n L I 1-7 'rt� .. - b N�• 5 #1473 L 1 q I R/ I I E ENT - ENTRY I I ENTRY I -I SIG1009-. I I —__ I _ _ DN DN ` I CITY VI REDMOND slca.14 E�.jLL.I slcsa+a Ir D VI AD o MwOaW a c I De#16-B-141co 1 1 I I O W �? W _ W oUT K C 2 N z F 6 d Q U = 3000� ,7 Ir 3RD FLOOR �ZOw.x N aoYa's 3OCOca p�Yw�w OmzEO Y W Ou.mY mmww6K 2 p r U w 614THHNISBIL TO THE FAC 3Y�<R_O LOCATED IN BUILDING 17 i �¢�w w^'C a DUN—,aw z REVISION RECORD F DATE/DESCRIPTION z Sze, �F1612 THHN(SLC)TO THE FACP C LOCATED IN BUILDING 17 I I' _ - SHEET LIST 1 Ts Fs FA 0.0 FA DETAILS 1 Z 20^ zN,•oo, _ _ II FA 1.0 FIRE ALARM cam— ENLARGED — I I UNRD-7 FA 2.0 RISERICALCS UN RISER ROOM slG,.00x UNIT D3 �UNIT � UNIT D-2 r— UNIT DS siGaocy UNIT D-6 �- t t UNITD� S IN THE RI ER TROOM B I -----" -- -�s,G,wae uNRw I YY A I 11Ti� I`R fIG2.o— AJ t �7 � O II II- ------------ - ____ __ ,. .�� sTNFU I I STAIR/ ;' ��-- ------- r slaw j I___ STAIR/ J I,�I I_ } SCALE:1/8"=1' t I ENTRY I ENTRY I I DATE: 1Dt1D/16 I I ENTRY I ENTRY I I I I—`�� G.o I up t-6 up I _H soo, PROJECT NAME 16/4 FPLR SIG 1 TO THE Gz ma ^4 s SIG— slc+•o+a IN THE RISER ROOM L I �� Z 51G. 81GI•WI Blp,-003 EOI NGC SIGx Ott .� I SIG2003 I GIG09� EaL we SIGt-011 SIGI-0,0 it .,0 I W LU I I� � N V Q Z t Q Z O A — I. H UP UP noco r j ^ Z swaooa m CD 1 ST FLOOR N 2ND FLOOR N a N a 0- SHEET DESCRIPTION FIRE ALARM SHEET NUMBER FA 1 .0 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 HRE PROTECTION INC- 1730 Gibson Road Everett,WA.96204 425-290-9600 DAVID MOW Battery Calculations for Panel:PS BUILDING 15 ® v Part No:PSN-10D0-INTELLIGENT 10AMP REMOTE POWER EXPANDER Part No. Qty. Description Standby Total Standby Alarm Total Alarm 120904, Panel Equipment LEVEL III PSN-1000 MB 1 10AMP POWER EXPANDER MB 75.000OmA 75.000OmA 215.0000mA 215.0000mA Total Panel alloy 75.0000nA Total Panel Alarm 215.03DOmA Peripheral Devices 2W-B 1 SMOKE,PHOTO,2-WIRE(Initiating) 0.01IXMnA 0.0100mA 6.5000mA 6.5000mA P31-IT 1 PULL STATION SINGLE ACTION(Initiating) 0.0000mA 0.0000rrA O.000OmA 0. MKT-1224W 12 MINI HORN,WH(Notification) 0.000OnA 0.0000muk 22.000OmA 264.00013mA D GHLFW 23 HORN LOW FREQUENCY.WH(Notification) O.0000mA 0.0000mA 99.4000mA2286.2000mA NFPA HS-24WR 1 HORN/STROBE,2 WIRE,M-C,RED,WALL(Notification) O.000OmA O.0000mA 186.000OmA 188.0000.A Tolel Peripheral Slby O.Ot00mA Total Periph Alarm 2742.7000 000805173 Total Standby Amps 75.0100mA Total Alarm Amps 2957.7000.A ROY L CATS Standby time:24 His 1.SM Q-SOTECl @��^�y Alarm time:5 Min 0.246 w ■■,��`,, ■■, Battery requirement 2.047MM Compensation Factors-Standby:1.2 Alarm:1.2 Requirement with compensation: 2.458M b NFRW C and y5 CFPB #1473 Circuit Calculations Panel:PS Card:00 Circuit:SIG1 Circuit Calculations Panel:PS Card:00 Circuit:SIG2 Circuit Calculations Panel:PS Card(00 Circuit:SIG3 �& CircuitName:SIG CIrcuhName:SIG2 CircuitName:SIG3 CITY OF REDMOND Circuit Type:Notification Terminal Voltage:20.4V:DC Amperage:3.lXg0A Circuit Type:Notification Terminal Voltage:20.4V:DC Amperage:3.0000A Circuit Type:Notification Terminal Voltage:20.4V:DC Amperage:3.0000A DAVID MOW Cable:16/4C TWISTED FPLR#16 Cable:16/4C TWISTED FPLR#16 Cable:16/4C TWISTED FPLR#16 Calculations based on Running Total Length. Calculations based on Running Total Length. Calculations based on Running Total Length. na#16-B-141co Design Criteria:Ambient temperature:167'F Max.operating voltage drop:15% Design Criteria:Ambient temperature:1676F Max.operating voltage drop:15% Design Criteria:Ambient temperature:167'F Max.operating voltage drop:15% Device Part No Appliance Desc Distance Current Vottage Vottage Drop Device Part No Appliance Desc Distance Current Voltage Voltage Drop Device Part No Appliance Desc Distance Current Voltage Voltage Drop PSN-1000 Panel 20AV PSW1000 Panel 20AV PSN-1000 Panel 20.4V p 001 GHLFW HORN LOW FREQUENCY,WH 59 99.4000nA 19,861 TV (0.538MI 001 MHT-1224W MINI HORN,WH 17 22.0000mA 202745 (0.1255V)l 001 GHLFW HORN LOW FREQUENCY,WH 58'-0 99.4000mA 20.0118V (0.3862V) w C 002 MHT-1224W MINI HORN,WH 91-0 22.0000mA 19.7641 (0.0777V) 002 GHLFW HORN LOW FREQUENCY,WH 10' 99.4000.A 20.1721 (0.1024V) 002 MHT-1224W MINI HORN,WH 9-0 22.0000mA 19.977 (0.0343V) - 003 GHLFW HORN LOW FREQUENCY,WH 10' 99.400DmA 19. (0.0842V) 003 GHLFVV HORN LOW FREQUENCY,WH 7-0 99.4000mA 20.1 (0.01 GHLFW HORN LOW FREQUENCY,WH 17-0 99.40DOmA 19.9114V (00661V) -ac w�n W 004 GHLFW HORN LOW FREQUENCY,WH V 99.400DmA 19.677 (0.0224V) D04 HS-24WR HORN/STROBE,2 WIRE,M-C,RED,WALL,IIDCD IY 186.0000mA 20.045 (0.1079V) 004 GHLFW HORN LOW FREQUENCY,WH 44'-0 99.4000mA 19.7119 (0.1995V) w m V m K C DD5 GHLFW HORN LOW FREQUENCY,WH 49-0 99.4000.1A 19.3601 (0.3174V) 005 GHLFW HORN LOW FREQUENCY,WH 2D 99.4000mA 19.9161 (0.1296V) 005 MHT-1224W MINI HORN,WH 36-0 22.000OMA 19.583 (0.1282V) 2 u y 6 to DOG MHT-1224W MINI HORN,WH 3-P 22. 19.1 (0.2037V) ON MHT-1224W MINI HORN,WH 36' 22.000OmA 19.7179 (0.1982V) GHLFW HORN LOW FREQUENCY,WH 9-0 99ADOOmA 1956M (0.020114 Q U = 007 GHLFW HORN LOW FREQUENCY,WH 9-0 99.40ODMA 19.12 (0.0317V) 0D7 GHLFW HORN LOW FREQUENCY,WH 5 99.4000mA 19.6862 (0.0317V) 007 MHT-1224W MINI HORN,WH 37- 22.000OmA 19.487 (0.076V) 0 O U ir DDB HT-1224W MINI HORN,WH W 22.000OmA 18.9951 (OA296V) U08MHT-1224W MINI HORN,WH 1 37 22.0000mA 19. (0.1382V) 0081 GHLFW HORN LOW FREQUENCY,WH V-0 99.4000mA 19.47 (0.013V) G O a a N 009 GHLFW HORN LOW FREQUENCY,WH 6' 99. 18.97 (0.0246V) 009 GHLFW HORN LOW FREQUENCY,WH 8' 99,1000.A 19.5233 (0.0246V) MKT-1224W MINI HORN,WH 3g'-0 22c000.A 19.439V (0.0356� 2 O w H a 010 GHLFW HORN LOW FREQUENCY,WH - 99. 18.83 (D.1378V) 010 GHLFW HORN LOW FREQUENCY,WH 24' 99A000MA 19.4482 (0.07 01 GHLFW HORN LOW FREQUENCY,WH V-0 99.40DOmA 19.4332V (0.0058V) a O a O J 011 GHLFW HORN LOW FREQUENCY,WH 2'-0 99. 18. (0.0043V) O O m K O 011 GKLFW HORN LOW FREQUENCY,WH 7 99.4000mA 19. (0.0043V) 236-0 684A000mA t IX O ri N 012 HT-1224W MINI HORN,WH 15 D 22.000OInA 18b1 (0.0178V) 012 MHT-1224W MINI HORN,WH 15 22. 19.4261 (0.0178V) Total CurterR 664.4000nIA m C ly H 013 GHLFW HORN LOW FREQUENCY,WH 6-0 99A000rnA 18.805 (0.0049V) 013 GHLFW HORN LOW FREQUENCY,WH 5 99.400D.A 19.4212 (0.0049V) (Toml VDrop Peroerit4.74%) Totel Voltage Drap:0.9B68V Z F w 272' 982.6000 3 H- 183' 1(169.2000mA a Total Current:982.60DOmA }>a O (Total VDmp Percent7.82%) Total Votage Drop,1.5943V Total Current:Drop 0.9788V ~ra lu tl C 6 (Total VDrop Percent:4.t1096) Total Voltage Drop:09788V O O w N�a w REVISION RECORD DATE/DESCRIPTION SHEET LIST FA 0.0 FA DETAILS FA 1.0 FIRE ALARM FA 2.0 RISER/CALCS B g LF H LF H LF H F11111 LF H LF SCALE: 1/8"=1' L1 H LF LF LF H LF H LF floca LF LF H F DATE: 10/10/16 PROJECT NAME o PS BLDG 15 LF LF LF LF LF L,yF LF LF LF c)1`� 1- W H P H Sy H ii & H & J Z Q TS F- it n Q Z A FACP Fs Z = O 1 XDEDICATED 120-1 20AMP IN Me ..h'On ll I' A CIRCUIT IS REQUIRED BLDG 17 ANN Q t` Z Ym (V X (D Q 14 SHEET DESCRIPTION FIRE ALARM CALCS/RISER SHEET NUMBER FA 2.0 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 FIRE PROTECTION INC. 1730 Gibson Road Everett 98204 425-290-90-9800 INSTALLATION NOTES ONDUIT WITH �g L D G. 1 � \ DAVID MOW 1 CONDUIT ROUTES ARE FOR REFERENCE, EXACT 6x THHN#16 1 x RED,1 x BLACK ROUTE TO BE DETERMINED BY THE ELECTRICIAN. 1 x BLUE,1 x WHITE \ BUILDING LINKING MUST BE DONE AS SHOWN FOR 1 xGREEN 1 xYELLOW \ A CLASS A LOOP AND PROJECT PHASING. 120904, \ \ / LEVEL III p 2)JUNCTION BOXES SHOWN ARE TO BE LOCATED IN THE FIRE SPRINKLER RISER ROOM OF EACH / \ \ BLDG 12 �� �� n BUILDING OR ON THE EXTERIOR WALL OF EACH . SPRINKLER RISER ROOM WITH A MINIMUM OF 16 J \\ \\ 4 f BLDG. 11 _ NFPA AWG WIRE AS SHOWN. JUNCTION BOX LOCATIONS 000sos173 SHOWN ARE BASED ON INDIVIDUAL BUILDING \ ROYL CATS ONDUIT WITH ONDUIT WITH Qaoreo> PLANS. i x THHN#16 x THHN#16 1 x RED 1 x BLACK 1 x RED,1 x BLACK ONDUIT WITH w 1 x BLUE,1 x WHITE 2 X THHN#16 L'1►J BLDG. 14 1XBLUE,IXWHITE 3) BUILDING LINKING CONDUITS/WIRING TO BE RUN 1 x GREEN,1 x YELLOW � 1x GREEN,1xYELLOW �' ,J 2xRED,2xBLAC b�JNFPAyyc TO A GUTTER IN THE ELECTRICAL/MECHANICAL `� \ 2x BLUE,2x WHIT E CFPS ROOM IN BUILDING 17 THE SITE FACP IS LOCATED 2x GREEN,2xYELLOW #1473 IN BUILDING 17). \\ \� / I I I I �& 4 ALL FIRE SPRINKLER RISER ROOMS REQUIRE 1 x ONDUIT WITH I I I CITY OF REbMOND DEDICATED 120VAC 20AMP CIRCUIT FOR EACH \ xTHHN#16 ONDUITWITH - C .,abnswo MO o BLDG. 17 xTHHN#16 1 x RED,1 z BLACK o.#16-B-141 w REMOTE POWER SUPPLY. 1 x DEDICATED 120VAC J- �� 1 x BLUE,1 x WHITE 1 x RED,1 x BLACK 20AMP CIRCUIT IS REQUIRED AT THE MAIN FACP IN \, 1 xGREEN,1 xYELLOW 1 x BLUE,1 x WHITE I 1 1 1 cn Community w 1 x GREEN,1 x YELLOW Q BUILDING 17 ( SEE FIRE ALARM DRAWINGS FOR oNDu1TWITH GEC ROOM II I T. d� w BUILDING FIRE ALARM DETAILS). -ONDUIT WITH xTHHN#16 Building �. _��� W x THHN#16 1 x RED,1 x BLACK G —m W N y w,oVm 'wx 1 x RED,1 x BLACK 1 x BLUE,1 x WHITE y � z#H a C 1 x BLUE,1 x WHITE t x GREEN,1 x YELLOW 1X GREEN,IX YELL OW oo� pS2 -BLD . 15� �� BLDG. 9 2 CI_ FilEXTERIOR OUTDOOR RATED JUNCTION BOX `� \ ® J ,,. _ __ N p o m a ONDUIT WITH __�� 1 a W p W a. x THHN#16 \ _ � , W 3o� a ` W 1 x RED,1 x BLACK N >a o a ELEC.GUTTER TO BE LOCATED IN ELEC RM OF BUILDING 17 \ J w La;; z a 1 x BLUE,1 x WHITE ����_ p O w N M w 1 x GREEN,1 x YELLOW \ g L D G. 10 ONDUIT TH REVISION RECORD \ WI x THHN M6 ^ DATE/DESCRIPTION 1 x RED,1 x BLACK {+� ONDUIT WITH 1 x BLUE,1 x WHITE x THHN ON WITH 1 x GREEN,1 x YEL I x LOW BLDG. 8 1 x RED, x BLACK x THHNHHN#16 r ` 1 x BLUE,1 x WHITE 1 x RED,1 x BLACKSHEET LIST r 1 x GREEN,1 x YELLOW 1 x BLUE,1 x WHITE 1 �.nnnnn�I I ' 1 x GREEN,1 x YELLOW Wuu BLDG. 16 N �� ONDUIT WITH o x THHN#16 B WI!® — 's—� f 1 x RED,1 x BLACK N J 1 x GREEN,1'xYETLLOW B _ BLDG. 5 ; J BLDG. 6, J BLDG. 7 a � N — ONDUIT WITH ONDUIT WITH x THHN#16 tu x THHN#16 1 x RED,1 x BLACK (� = 1 x RED,1 x BLACK _ t x BLUE 1 x WHITE \1 1 x BLUE,1 x WHITE 1 x GREEN,1 x YELLOW DATE: 10/10/16 ONDUITXTHH WITH 1 xGREEN 1 xYELLO e J� PROJECT NAME 2 X THHN#16 a 2 x RED,2 x BLACK 2 x BLUE,2 x WHITE 2 x GREEN,2 x YELLOW ~ LU I W Z Q BLDG. 1 ��BLDG. 2 BLDG. 3_ BLDG. 4 Q Z A Boa p� N ONDUIT WITH ONDUIT WITH d x THHN#16 x THHN#16 t x RED,1 x BLACK 1 x RED,1 x BLACK 1 x BLUE,1 x WHITE 1 x BLUE 1 x WHITE 1 x GREEN 1 xYELLOW 1 x GREEN,1 x YELLOW SHEET DESCRIPTION N FIRE ALARM SITE BUILDING 41 LINKING PLAN SITE BLDG LINKING PLAN E SHEET NUMBER 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 \ FIRE PROTECTION, INC. PO BOX 12642 MILL CREEK,WA 98082 14251 290-9600 OR 1-800-681-1125 FAX (4251353-4546 October 20,2016 City of ARLINGTON - PLAN REVIEW RE; FIRE ALARM SYSTEM Please find enclosed plans for a FIRE ALARM SYSTEM.The FACP will be located in building 17 ( lower floor of this building is the site community building) , all residential buildings will have their own individual fire alarm annunciator and remote power supply. All residential buildings sprinkler systems will be tied to and monitored by the FACP located in building 17 . The site electricians (Express Electric) are providing building linking conduit/wiring as shown on the included site building linking plan. The SLC and SBUS will be run in a Class A loop as shown. When a Waterflow, Smoke Detector or Pull-station is activated in a residential building, it will annunciate at the annunciator in that specific building and also at the FACP located in building 17 . Residential building occupant notification devices will only activate when an initiating device in that building is triggered, no other building' s occupant notification devices will active. The system has been designed per NFPA 72 , 2013 edition requirements as well as WAC, IBC, IFC 2012 , NEC current and your additional requirements . The building is fully-sprinkled. The system shall monitor by zone activation as well as separate trouble signals . Monitoring shall be provided via UL listed Central Station, The Alarm Center LACEY, WA. Audibility shall be in compliance with NFPA standards . Interior DB shall be 75 DB minimum throughout, (LOW FREQUECNY NOTIFICATION DEVICES TO BE INSTALLED IN RESIDENTAL SLEEPING AREAS . A full service and monitoring agreement is in force for the proper service and maintenance per NFPA requirements . A full pre-test and NFPA form shall be conducted and completed prior to calling the AHJ for acceptance testing. INSTALLATION COMPANY Fire Protection, Inc. 1730 Gibson Rd. Everett, WA 98204 WSCL# FIREPI*021ML UL CERT #608242-002 JOB SITE Park 77 Apartments *Building 15* 20201 77th Ave Ne Arlington , WA APPROVED UL MONITORING COMPANY Alarm Center, Inc. /FPI 4300 3rd Ave. SE Lacey, WA 800-429-0991 UL CERT #902799-02 CONTRACTUAL RESPONSIBLE PARTIES Installation; Monitoring; Service; Testing; Fire Protection, Inc. AMBIENT TEMPERATURES No area with alarm service equipment shall fall below 40 degrees, common areas shall be at 68 degrees per builder AMBIENT NOISE RANGE All areas serviced by the Fire Alarm Control and notification system will be as listed for per UBC listings, per builder. SEQUENCE OF OPERATIONS All Alarm and Trouble conditions shall enunciate at FACP as well as remote notify UL listed Central Station. Zones of alarm shall cause for all notification circuits to activate, send alarm zone to CS, re-dispatch to Fire and dispatch FPI runner service. Trouble and supervisory signals shall transmit to CS which will dispatch FPI runner service to site, (no notification circuits shall activate. ) On site emergency contact personnel shall be notified. Wet Waterflow ALARMS shall be retarded by a period of not more than 45 seconds . Low air shall activate at 25lbs, causing for a supervisory signal . A short on FACP smoke, Waterflow Switches, (wet and dry) and pull station shall cause a alarm. Shorts on PIV, tamper and Hi-low air zones shall cause a Supervisory condition. Opens on any zones shall cause for a trouble signal . Should you have any further questions, please feel free to contact me directly. David Mow VP of Operations/Designer NICET-3 #120904 CITY OF REDMOND D.O.R. #16-B-141 WA JOURNEYMAN LICENSE #MOW**DDE957M6 FACP FOR ALL BUILDINGS LOCATED IN BUILDING 17 @POTTER P 3 00 P/uS Fire Alarm Control Panel Features • 127 expandable to 381 Analog Addressable Points.Any combination of detectors/modules • 5 Amp Power Supply.Expandable to 315 amps • 2 NAC circuits rated at 3 amps maximum,expandable to 188. • 2 Input/Output(1/0)Circuits for system flexibility rated at 1 Amp . �• each _ • Built-in UL Listed IP Communicator • Built-in email event notification and report capability. • Optional Dual Line Digital Alarm Communicator • System wide synchronization of Potter/AMSECO,Gentex, Cooper/Wheelock,and System Sensor signals. • No twisted or shielded wiring required. • Cabinet will accommodate up to 18AH batteries.Panel will charge up to 55AH. • Capable of Class A or Class B wiring configurations • Built-in NFPA 72 compliant smoke detector sensitivity test • Dead-front cabinet design '' �. • 1000 Event History Buffer V` i NYC Fire Dept. Certificate of Approval Potter/Nohmi Protocol Features S735 7165-0328:0195 6156 • Less than 4 second polling time Product includes a 5 year warranty • LED's visible from 360' • Adjustable Smoke Detector Sensitivity • Adjustable Heat Detector Temperature annunciators,intelligent power supplies and other optional modules. • High Temperature Heat Detector as fixed temp The P-Link will support 31 accessories in any combination.The RA- Drift6075 is a 2 x 16 LCD annunciator.The RA-6500 offers a larger 4 x • Compensation 40 line LCD display that allows points and descriptions to be shown • Maintenance Alerts simultaneously.Intelligent remote power supplies repeat the P-Link data • Day/Night Mode and can be mounted 6,500 feet from reach other.P-Link devices such as the RLY-5 relay module,SPG-1000 serial parallel gateway and DRV-50 Description LED driver can be mounted anywhere in the chain of communication with a maximum of 31 of each P-Link devices.A total of two(2) The P300 is a mid-sized analog/addressable fire alarm control panel SLCE-127 Signaling Line Circuit Expanders(loop cards)may be with a total of 381 points.The points may be any combination of smoke installed in the P300 enclosure,in a remote enclosure such as the AE-8 sensors,heat detectors or modules.This panel has a 5 amp power supply or with a PSN-1000E remote intelligent power supply. that is distributed across two Notification Appliance Circuits(NACs) and two Input/Output(1/0)Circuits. The entire system,including the SLC,NACs and P-Link may be converted with a CA-6075 Class A module.The entire system is The NAC circuits are rated at a maximum of 3 Amps each and the 1/0 programmed using a Windows based computer software and requires circuits are rated for a maximum of 1 Amp each.All of the outputs may the use of a software programming software key. be configured for notification or auxiliary power.In addition,each NAC and Output can be programmed for strobe synchronization and utilizes The P300 can communicate to a monitoring station using the on board Quadrasync for strobe synchronization across circuits of various brands. Ethernet connection to an IP communicator or using optional UL listed The 1/0 may also be programmed for a dry contact input such as a water UD-1000 traditional two line alarm communicator.The UD-1000 flow switch or pull station. connects to the main board and has two phone line jacks provided. The IP communicator uses a RJ-45 connection and when connected The cabinet will hold two 12 volt,8 amp/hour batteries or two 12 volt, to the intemet may be programmed to E-mail system status,history 18 amp/hour batteries.The system when fully loaded will charge 55 reports,reminders and the configuration file.The panel may be updated amp/hour batteries.Anything larger than 18 amp/hour will require an remotely using the LTD-1000.If the Ethernet connection is needed external battery cabinet the SSU-00050. remotely,the FCB-1000 fire communication bridge may be installed to The panel has the Potter P-Link connection for expansion with remote allow the Ethernet connection to be installed in a rack. Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • wwpottersignal.com P'�O�IUsJ w. #8830035-REV A PAGE 1 OF 4 08/12 (E) POTT ER P 3 00 Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 381 addressable devices or modules in any combination.The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PSA Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PSHA Combination Analog Photo Electric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135'Fahrenheit heat detector FHA Analog Fixed Temperature Heat Detector that is selectable from 135'F to 185°F RHA Analog Rate or Rise Heat Detector that has a fixed temperature selection from 135°F and 174°F and also will alarm if the temperature increase 12-15°F in one minute DDA Addressable Duct Smoke Detector AB-6 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors AB-4 4"round base that may be mounted to an electrical box and wired for connection to the above sensors AIB Isolater base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop ARB Addressable Relay Base that contains two relays controlled by the SLC.One relay is rated at 8 amps at 240 VAC/30VDC and the other is rated at 2 amps 240 VAC/30 VDC ASB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call. Modules Device Description MCM Miniature Contact Module provides a small foot print contact module for mounting inside an enclosure. APS-SA Single Action Addressable Pull Station APS-DA Dual Action Addressable Pull Station SCM-4 Single Contact Module is a standard contact module with an LED that mounts into a 4"square electrical box. DCM-4 Dual Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. TRM-4 Twin Relay Module provides two form C relays that simultaneously active when the module is triggered by the control panel. Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC. MOM-4 Monitored Output Module is a power switching module that monitors the circuit that is controlled by the control panel. CIZM-4 Conventional Input Zone Module is used to connect conventional smoke detectors to the system that receive their power from the module.This module is like a conventional zone on the SLC. SCI Short Circuit Isolater interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • www.pottersignal.com P"�O�A'SP v #8830035-REV A PAGE 2 OF 4 08/12 (E) POTT ER P 3 00 Fire Alarm Control Panel SLC Features RA-6075—2 x 16 LCD annunciator with a key pad in a locked metal enclosure. The Potter/Nohmi protocol is a digital protocol with a proven design for reliability and noise immunity.The system does not require special RA-6500—4 x 40 LCD annunciator with a key pad in a locked metal cable or conductors for connection of the Signaling Line Circuit as enclosure long as the cable is compliant with NFPA 70 and NFPA 72.The system LED-16—16 LED annunciator with common indicators in a locked allows for Class A or Class B installations as well as"T-Taps." metal enclosure The total polling time for the protocol is about four(4)seconds which PSN-1000(E)—10 amp,remote intelligent power supply with 6 NACs, allows two polling cycles in the ANSUUL 864 requirement of alarms 2 I/Os and a P-Link repeater reporting in less than ten seconds.Each loop is capable of 127 points with the exception of the P100 and P200. CA-6075—Class A convertor that converts the SLC,NACs and P-Link connection Sensor Features UD-1000—UL listed,Dual line telephone alarm communicator The sensors through the fire alarm control panel provide a real DRV-50—LED driver expander,used to connect up to 50 LEDs in a time status as to the condition of the system.The smoke detector graphic display sensitivity,heat detector temperature level and drift compensation FCB-1000—Fire communication bridge,provides remote mounting of as all programmable options.The system also allows for a day/night the Ethernet connection mode where the panel automatically adjusts the sensitivity depending on the time of day.To assist in the reduction of false alarms,the smoke FIB-1000—Fiber interface module,used to extend P-Link to multi- detectors also have a maintenance warning that sends a trouble signal mode fiber(2 required) when a detector is dirty to the point that it can no longer maintain the RLy--5—Relay module,provides 5 form C relay contacts rated at 3.0 programmed sensitivity. amps 24VDC/125AC User Interface SPG-1000—Serial parallel gateway,allows for the connection to a serial or parallel printer The fire alarm control panel has a 4 x 40 LCD display to provide information to the system status.The keypad has navigation keys The FIB-1000,FCB-1000 and the SPG-1000 maybe installed in the t stacker bracket or ordered with the optional rack mount enclosure.o allow manipulation of the Menu on board the panel.The panel is shipped standard with the following LEDs: AE-8—Eight card expansion cabinet • AC Power—Green AE-14—Fourteen card expansion cabinet • Alarm—Red Ethernet/I.P. Connection • Earth Fault—Amber The P300 is shipped standard with an Ethernet connection.This • Supervisory-Amber connection is the programming port and may be connected to a building • Silenced-Amber Wide Area Network(WAN)or Local Area Network(LAN).Once connected to the Internet,the panel may be selectively programmed to • Trouble-Amber e-mail alarm conditions,trouble conditions,supervisory conditions,test, The common buttons include a Silence,Reset,Acknowledge and Drill. Event History and detector status.An e-mail may be sent to the panel All of the buttons are accessible once the locked door is opened. and the panel will e-mail the event history,detector status,configuration file or server status to an authorized E-mail account.In addition, P-Link reminders may be set to send an e-mail for service,testing or other The P300 has a proprietary communication protocol that communicates conditions. through a RS-485 connection to field devices.Up to thirty-one In addition,the Ethernet connection is UL listed as an IP communicator. (31)devices may be connected to a single P-Link connection.The The IP communicator is listed to report to the UL listed Sur-Gard III P-Link includes the communication terminals and regulated 24 VDC IP receiver.The IP communicator replaces the traditional less reliable connection for the field devices.The field devices may be any of the alarm communicator transmitter that utilized telephone lines.The IP following: communicator is an active method of connection and communication to SLCE-127-Analog/Addressable loop expansion module(maximum of 2 the monitoring station. per P300) Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • wwpottersignal.com P'��PlusZ* w. #8830035-REV A PAGE 3 OF 4 08/12 (E) POTT ER P 3 00 Fire Alarm Control Panel Specifications 18.91" 17.60" Electrical Specs:AC Mains O O TOP o 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @ 240 VAC 50/60 HZ 4.41" 3.75" DEPTH Battery p 0 130 mA Standby 220mA Alarm b • 5 Amps power for NACs,I/O and P-Link • 3 Amps per NAC,regulated a • 1 Amp per I/O circuit,regulated �e c7 O • Battery Charger range 8-55 Ah • Battery Charger voltage 27.3 VDC • P-Link maximum current of 1 Amp • Panel holds(2)8AH or(2) 18AH batteries LEFT SIDE RIGHT SIDE Cabinet • 16 gauge cold rolled steel with removable BOTTOM ` locked door • Dimensions—18 15/16"W x 27 5/16"H x 4 7/16"D • Dead front to cover all electronics • Lexan viewing window Temperature and Humidity This fire alarm control is listed and approved for operation in an indoor application with temperature range fluctuations of 32'to 120'(0°C to 49°C) with a maximum humidity of 93%non-condensing.The ideal temperature is 77°F +/- 10°F(25°C+/-5°C). Standards The P300 series fire alarm control panel complies with the following standards and codes. • NFPA 13,70 and 72 • ANSI/UL 864 0 Local(L),Remote Station(RS),Central Station(CS),Propriety(PPU),Auxiliary(AUX) 0 Type of Service:Automatic(A),Manual(M),Water flow(WF)Sprinkler Supervisory(SS) 0 Type of Signaling:Digital Alarm Communicator(DAC),March Time(March),Non Coded(NC),Reverse Polarity(Rev Pol),Other Technologies(OT) • IBC 2000,2003,2006,2009,2012 Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • wwpottersignal.com P'h�T PUF'J w. #8830035-REV A PAGE 4 OF 4 08/12 POTTER RA-6075 The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Features Standby Current 20 mA Alarm Current 25 mA Operating Temperature 0°C-49°C(32°F-120°F) 10%-93% @ 30°C(86°F)non-condensing 0 © humidity Maximum Wire Length 6500 FT ® © Maximum Annunciators 31 - Dimensions(WxHxD) 8"x 6-1/4"x 1-5/8"(Cabinet) Wire Gauge 14 AWG-22 AWG Display 2 lines x 16 characters Product includes 5 year warranty U� LISTED S2930 7165-0328:0195 Description Installation The RA-6075 is a LCD remote annunciator for the PFC-6075 and The RA-6075 is connected to the PFC-6075 using a four wire RS-485 PFC-6030 addressable fire control panel.The RA-6075 communicates connection.The connection is power limited and supervised.Up to using a RS-485 connection to the main panel providing common thirty-one(31)RA-6075 LCD annunciators can be connected using indication of Alarms,Supervisory,Trouble and other system status and Class B or Class A wiring.Class A wiring requires an optional Class A control functions. Expander. The RA-6075 features a 32 character, 16x2 LCD display with LED's for Power,Alarm,Supervisory,Trouble,and Silenced conditions. , It can be mounted on a single gang electrical box or a four square electrical box.The annunciator is enclosed in a sheet metal enclosure Instal!inac!cord!anc!e with compatib7fir,alarm panel. and has a Potter lock securing the keypad. Figure 1:RA-6075 Class B Wiring Example Figure 2:RA-6075 Class A Wiring Example To the next annunciator 4CA-60775 + m + a P-LINK + a + A B + + + + Panel + + + + + + Panel + + Connection Remote -LIN + Annunciator Connection + Remote -LIN< Annunciator m Q m Oa O a + Q O Remote O Remote Annunciator Annunciator Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#5406077-REV B-1 PAGE 1 OF 2 9/11 (E) POTTER RA-6075 The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Address Settings The RA-6075 address is set by dip switch S 1 located on the back of the RA-6075.The address must be set in the range of 1 to 31 to be recognized by the control panel. Figure 3:RA-6075 Class A(back panel view) O ❑ 0 0 OWWWW .-9. O 0 © A on ® 9 ® + Al O o Dip Switch Settings Refer to the table below for dip switch settings per Annunciator Address. Annunciator Dip Switch Settings Annunciator Dip Switch Settings Address SW-1 SW-2 SW-3 SW-4 SW-5 Address SW-1 SW-2 SW-3 SW-4 SW-5 1 On Off Off Off Off 17 On Off Off Off On 2 Off On Off Off Off 18 Off On Off Off On 3 On On Off Off Off 19 On On Off Off On 4 Off Off On Off Off 20 Off Off On Off On 5 On Off On Off Off 21 On Off On Off On 6 Off On On Off Off 22 Off On On Off On 7 On On On Off Off 23 On On On Off On 8 Off Off Off On Off 24 Off Off Off On On 9 On Off Off On Off 25 On Off Off On On 10 Off On Off On Off 26 Off On Off On On 11 On On Off On Off 27 On On Off On On 12 Off Off On On Off 28 Off Off On On On 13 On Off On On Off 29 On Off On On On 14 Off On On On Off 30 Off On On On On 15 On On On On Off 31 On On On On On 16 Off Off Off Off On PRINTED IN USA MFG.#5406077-REV 13-1 PAGE 2 OF 2 9/11 CPOTTER PSN-1000(E) The Symbol of Protection POWER EXPANDER Features 10 Amp Power Supply • 3 Amps,regulated per NAC • 6 NACs Class B or 3 NACs Class A • 2 dry contact inputs • Fully programmable and monitored through control panel _ I Isolated P-Link repeater connection,Class A or B • Up to 31 power supplies per control panel with system wide sync • Quadrasync feature synchronizes strobes from Potter/AMSECO, Gentex,Cooper-Wheelock and System Sensor. ®RPOTTFR PSN-1000 Compatible with all Potter PFC-6000 series fire alarm control panels. Ines➢pool of Frowpon P.—Supply --. Electrical Specs • 120/240 VAC Input at 50/60 HZ • 5.1 Amps/3.0 Amps max draw • Standby Current 60 mA • Alarm Current 200 mA U` S2930 7165-0328: 0195 Product includes a 5 year warranty Description The PSN-1000 series is a UL listed intelligent 10 amp notification power supply and P-Link(RS-485)repeater.The power supply connects to the P-Link bus from the control panel and is operated and supervised from the panel.The power supply may be installed 6,500 feet from the control panel.The PSN-1000 then repeats the P-Link communication for another 6,500 feet. The power supply has six(6)Class B or three(3)Class A power outputs.Each output is regulated and power limited with a 3 Amp maximum rating.In addition,the PSN-1000 has two(2)programmable dry contact inputs.The dry contact inputs are Class B,supervised inputs. The power supply operates on either 120 or 220 VAC power and has a regulated 24 VDC output.In addition,the panel can charge up to 55 AH batteries and will house 18 AH batteries.The cabinet is constructed out of 18 gauge cold rolled steel with a durable red powder coat finish.A standard Potter key lock is provided for securing the door.Electrical conduit knockouts are provided on the sides and top providing installers with multiple options for installing conduits and providing proper power separations. The PSN-1000 is a self contained intelligent power supply/P-Link repeater complete with cabinet.The PSN-1000E is the intelligent power supply/P-Link repeater with additional cabinet room for the exclusive Stacker Bracket for SLCE-127 loop expanders.Both cabinets include space for 18 AH batteries. The power supplies are programmed and controlled through the main control panel P-Link bus.The panel displays any troubles or off normal conditions of the power supply and the events are stored in the panel history buffer. Each output can be independently configured to provide one of four synchronization patterns,constant power,ANSI temporal Code 3 or Door Holder power.The panel can be configured to synchronize Potter/AMSECO®,Gentex®,Cooper Wheelock®and System Sensor®. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830032-REV B PAGE 1 OF 2 09/14 (E) POTTER PSN-1000(E) The Symbol of Protection POWER EXPANDER 18.91" 17.60" 4 0 0 TOP w 0 4.41" 3.75" DEPTH O O 0 0 0 N O O O 0 LEFT SIDE RIGHT SIDE BOTTOM Dimensional drawings showing the cabinet in all three planes. Knock out locations. PRINTED IN USA MFG.#8830032-REV B PAGE 2 OF 2 09/14 4, �� SYSTEM � SENSOR t 41, Photoelectric Smoke Detectors System Sensor i3-series smoke detectors represent significant advancement in conventional detection. 3 The i3 family is founded on three principles:installation TM ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its •Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included with heads).The large wire entry port and in-line terminals provide Large wire entry port ample room for neatly routing the wiring inside the base.The base •In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single-gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,i3 boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock'action. •Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features •Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and •Built-in remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize nuisance alarms.2-wire i3 detectors can generate a remote LED- indicated maintenance and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 •Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i3 •Wide-angle,dual-color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof i3 Loop testing via EZ Walk feature detectors in terms of percent-per-foot obscuration. • •Built-in test switch Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on 2-wire P detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. T istin s M MEA MSFMTPROVED approved approved cC I,us I W6 7272-1653:152 290-01-_ 3C93? (-L3)Smoke Detector Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 1357 (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5 V Maximum:35 V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 NA maximum average;4-wire:50 NA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V Peak Standby Current 2-wire:100 uA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 1207(0°C to 49°C);2WT-B and 4WT-B:327 to 1007(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 1357(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:417(5°C) Sensitivity 2.50/o/ft nominal Input Terminals 14 to 22 AWG Mounting 3'/2-inch octagonal back box 4-inch octagonal back box Single-gang back box flinch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12 V,23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V,23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter f_ SY TE� m2cha system Sensor. �/ 3825 Ohio Avenue•St.Charles, L 60174 Product specifications subjec[to009 System Sensotice.Vsit rystemsensoccom for SENSOR Phone:800-SENSOR2•Fax:630-377-6495 urrentproductinformat5-03180i7-6/09 latest version okhis data sheet. A06-0318-007.6/09•#2169 P POTT ERS A ka-"Wl' DCM-4 ® The Symbol of Protection Dual Contact Module Features • Single module with dual contact monitoring inputs • Two(2)Class B or one(1)Class A monitoring inputs • SLC Class A(Style 6,7)&Class B(Style4) • Mounts in a standard 4"or double gang box s- S. • Wiring terminals accessible when mounted in box ©E�►•■-�+•�.+o • All wiring terminals accept 22 to 14 AWG li wsiar • Product includes a 5 year warranty ee _.. NOTE: This addressable module does not support 2-wire smoke f zz1,1" zi ;, ci detectors. Stock Number: 1430822 LISTED �zw� S2930 7165-0328:0196 Application Technical Specifications The DCM-4 is compatible with Potter's PFC-6000 series and PFC- Operating Voltage 22.0-24.OV 8500 addressable fire alarm control panels.The DCM-4 is an interface Max SLC Standby Current 325 µA module used to monitor dry contact devices such as sprinkler water Aux Power Required 1mA flow,valve tamper switches,or conventional pull stations.The module is capable of monitoring two separate Class B or one Class A circuits. Max Wiring Resistance of IDC I 100 S2 Max Wiring Cpacitance of IDC 1 µF EOL Resistor 5.lK S2 Description Operating Tempurature Range 32 to 120°F(0 to 49°C) The DCM-4 uses two (2) consecutive SLC loop addresses when Operating Humidity Range 0 to 93%(non-condensing) monitoring two(2)Class B circuits or one(1)address when monitoring 127 units(Class A)or 63 units a single class A(Style D)circuit.The module mounts on either a 4" Max no.of Module Per Loop (Class B) square or double gang box.The module is capable of monitoring two (2)separate class B circuits making it ideal for monitoring sprinkler Dimensions 4.17"(106mm)L X 4.17" waterflow and valve tamper switches when they are located in the same (106mm)W X 1.14"(29mm)D proximity.The DCM-4 includes one red LED to indicate the modules Standard 4"Square or status.In normal condition,the LED flashes when the device is being Mounting Options Double Gang Box polled by the control panel.When a contact is activated,the LED will Shipping Weight 0.6 lbs light continuously and in case of an open circuit,the LED will turn off. Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com 8830008-REV B • 7/14 PAGE 1 OF 2 P POTT ERS OHM/® DCM-4 ® The Symbol of Protection Dual Contact Module Setting the Address Each addressable module, smoke sensor,heat detector and combination sensor/detector must be assigned an address prior to installing the device.The address is set using either the hand held device programmer or the addressing feature on the PFC 6000/PFC 8500 Series control panels.When the DCM- 4 is used to monitor two individual Class B circuits a single device address is assigned,with the second address number assigned automatically by the module assuming the next consecutive address.For example,if the first address number is assigned as"2",the second address number will automatically be assigned as SLC device address"3". Before connecting a device to the SLC loop,take the following precautions to prevent potential damage to the panel or device verify the following: 1.Power to the device is removed 2.Field wiring is correctly installed. 3.Field wiring has no open or short circuits. Installation Using Compatible Electrical Box O e ° ° o e Wiring Diagrams DCM-4 With One Class ACircuit NOl FROM FACP OR C 1 PREVIOUS MODULE S+ ZI S- NO2 TO THE NEXT MODULE F 1 C2 SELECT STYLE D 0000 LED Q Z2 NOTE:END-OF-LINE RESISTOR IS NOT REQUIRED DCM-4 With Two Class B Circuits NOl FROM FACP OR C 1 PREVIOUS MODULE S+ Zl "OHM1/2W S- NO2 TO THE NEXT MODULE ppH1pC2 �000 LED O Z2 SELECT STYLE B 5.1K OHM 1/2W Potter Electric Signal Company,LLC St. Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 www.pottersignal.com :so 9001:2008 1 DESIGNING,MANUFACTURING, 8 DISTRIBUTING QUALITY SYSTEMS 8830008-REV B • 7/14 PAGE 2 OF 2 PULL STATION SERIES (E) POTTER DIE-CAST METAL The Symbol of Protection MANUAL PULL STATIONS • UL and cUL Listed,FM Approved,CSFM Listed,MEA ' Approved,ADA Compliant • Single or Dual Action • Terminal connectors PULL UOWN Big . 10 Amp Snap Action Switch Gold plated SPST contacts Optional auxiliary contacts Mounts on standard single gangbox • Surface backboxes available • High-gloss red enamel finish • Glass breakrod DUs FMo �5 Made in the U.S.A. LISTED Description Engineering Specifications The Potter Pull Station Series offers a complete line of die-cast pull The contractor shall furnish and install the Potter series of pull stations for a variety of applications focusing mainly on fire alarm stations as indicated.The pull station shall be die cast construction systems.The pull stations are available in single or dual action with a"T"type pull handle that is ADA compliant.Single action pull models.All of the pull stations have a 10-amp snap action switch and stations shall be a P32-lT.Dual action pull stations shall be the Potter a dedicated terminal block for the ease of wire connections.All of P32-1T-LP.Any manual pull station installed in an outdoor or wet the metal is completely coated to inhibit corrosion and provide for a location shall be a RMS-IT--WP weather proof unit.The contact shall uniform and quality finish. be a single pole,single throw switch rated at 1 amp 30V DC/125V The standard models have a hex key reset,however a key reset is also AC.The device shall have a terminal block for ease of wiring.Once available.The models are available with shallow and deep surface activated,the pull station shall be reset by opening the front cover. mount back boxes and as a weatherproof version. Opening of the cover in a normal state shall initiate an alarm. Operation Specifications The Potter single action series of pull stations operate by pulling Switch Rating: 1 Amp @ 30 VDC the white operating handle straight down and the handle will lock 10 Amps @ 125 VAC into place.The dual action stations require the lifting of the front Pull Station Dimensions: 4-3/4"H x 3-1/4"W x 7/8"D cover and then pulling the white operating handle straight down.The Color:Red with raised white letters,white pull bar with raised red letters stations are reset by opening the front and placing the handle in the For special application manual stations see bulletin#8910014. normal position. For explosion proof manual stations see bulletin#8880014. Ordering Information Type Model Number Stock Number Contact Type P32-1T 1000447 SPST RMS-2T 1000477 DPST Single Action RMS-6T 1000478 DPDT RMS-1 T-KL 1000451 SPST RMS-IT-KO 1000450 SPST,key operated,no pull Weather Proof RMS-1 T-WP 1000401 Dual Action P32-1 T-LP 1000476 SPST Weather Proof Dual Action RMS-IT-WP-LP 1000403 Accessories Notes Dual Action RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1000470 Replacement glass rods(10 per pkg) Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8900097-REV L PAGE 1 OF 1 9/10 PULL STATION SERIES (E) POTTER DIE-CAST METAL The Symbol of Protection MANUAL PULL STATIONS • UL and cUL Listed,FM Approved,CSFM Listed,MEA ' Approved,ADA Compliant • Single or Dual Action • Terminal connectors PULL UOWN Big . 10 Amp Snap Action Switch Gold plated SPST contacts Optional auxiliary contacts Mounts on standard single gangbox • Surface backboxes available • High-gloss red enamel finish • Glass breakrod DUs FMo �5 Made in the U.S.A. LISTED Description Engineering Specifications The Potter Pull Station Series offers a complete line of die-cast pull The contractor shall furnish and install the Potter series of pull stations for a variety of applications focusing mainly on fire alarm stations as indicated.The pull station shall be die cast construction systems.The pull stations are available in single or dual action with a"T"type pull handle that is ADA compliant.Single action pull models.All of the pull stations have a 10-amp snap action switch and stations shall be a P32-lT.Dual action pull stations shall be the Potter a dedicated terminal block for the ease of wire connections.All of P32-1T-LP.Any manual pull station installed in an outdoor or wet the metal is completely coated to inhibit corrosion and provide for a location shall be a RMS-IT--WP weather proof unit.The contact shall uniform and quality finish. be a single pole,single throw switch rated at 1 amp 30V DC/125V The standard models have a hex key reset,however a key reset is also AC.The device shall have a terminal block for ease of wiring.Once available.The models are available with shallow and deep surface activated,the pull station shall be reset by opening the front cover. mount back boxes and as a weatherproof version. Opening of the cover in a normal state shall initiate an alarm. Operation Specifications The Potter single action series of pull stations operate by pulling Switch Rating: 1 Amp @ 30 VDC the white operating handle straight down and the handle will lock 10 Amps @ 125 VAC into place.The dual action stations require the lifting of the front Pull Station Dimensions: 4-3/4"H x 3-1/4"W x 7/8"D cover and then pulling the white operating handle straight down.The Color:Red with raised white letters,white pull bar with raised red letters stations are reset by opening the front and placing the handle in the For special application manual stations see bulletin#8910014. normal position. For explosion proof manual stations see bulletin#8880014. Ordering Information Type Model Number Stock Number Contact Type P32-1T 1000447 SPST RMS-2T 1000477 DPST Single Action RMS-6T 1000478 DPDT RMS-1 T-KL 1000451 SPST RMS-IT-KO 1000450 SPST,key operated,no pull Weather Proof RMS-1 T-WP 1000401 Dual Action P32-1 T-LP 1000476 SPST Weather Proof Dual Action RMS-IT-WP-LP 1000403 Accessories Notes Dual Action RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1000470 Replacement glass rods(10 per pkg) Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8900097-REV L PAGE 1 OF 1 9/10 GENTEX CORPORATION Low Frequency Audible Signal GHLF Applications 24 V D C The GHLF is a high quality, low profile, low frequency audible appliance that offers a dependable audible alarm with a low current draw. The GHLF is ideal for any S E R I E S occupancy that requires notification appliances. The GHLF horn offers a 520 Hz square wave,temporal 3 tone. A jumper selection is available for normal or loud decibel tone. A temporal 4 pattern is available when used with the Gentex GTSM Synchronization Control Module. The GHLF is shipped with a standard 4" metal mounting plate which incorporates the popular Super-Slide°feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The GHLF also features the patented Checkmate°- Instant Voltage Verification feature which allows the installer to check the voltage drop and match it to the blueprint. The GHLF horn is listed to ANSI/UL 464 and CAN/ULC S525, is listed for use with fire Product Listings protective systems and is warranted for three years from date of purchase. SIGNALING Standard Features � • Nominal voltage 24 VDC • Input terminals accept 12 to 18 AWG C&uS :U0= O Unit Dimensions:6-1/8"(15.55 cm)high x • Produces a 520Hz square wave,temporal 3 LISTED 5-1/2"(13.97 cm)wide x 1-5/8"(4.13 cm) tone deep • Jumper selection for normal or loud dBA • ANSI/UL 464 Listed • Super-Slide®Bracket-Ease of Supervision • Temporal 4 pattern available when used • CAN/ULC S525 Listed Testing with Gentex GTSM Synchronization Module • CSFM: Pending • Checkmate°-Instant Voltage Verification • Temporal 4 520Hz measured per Product Compliance • Synchronize horn with Gentex GTSM ANSI/UL 2075 • NFPA 72 Synchronization Control Module • Tamperproof re-entrant style grill and • IBC/IFC/IRC • Prewire entire system,install mounting locking screw(optional use) • Quality Management System bracket,then install signals • Faceplate available in red or off-white is certified to:ISO 9001:2008 Model Number Part Number Nominal Voltage Model Designations: �i •j ' = R=Red Faceplate MEMBER •� GHLFW 904-0530-002 24 VDC W=White Faceplate ASSEMBLED IN GHLFR 904-0531-002 24 VDC All units are plain(no lettering) THE USA Horn Decibel Levels: 24VDC Nominal Horn Horn Current Ratings Reverberant Room Current Ratings(mA) Over Input Voltage Range of 16-33V(mA) Minimum SPL Minimum SPL 24VDC 24VDC 24VFWR 24VFWR Regulated Regulated Regulated Regulated at 10Ft.Per at 10Ft.Per Operating Operating Operating Operating 24VDC Max. 24VDC Max. 24VFWR Max. 24VFWR Max. Horn Mode Operating Operating Operating Operating ANSI/UL 464 ANSI/UL 464 Current Current Current Current Current Current Current Current (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) Temporal 3 520 Hz I 77.8 dBA 1 79.8 dBA 72.1 mA 120.1 mA 104.6 mA 158.4 mA 99.4 mA 155.8 mA 152.1 mA 213.5 mA Temporal 4 520 Hz*1 81.5 dBA 1 83.4 dBA 75.9 mA 116.0 mA 108.1 mA 182.0 mA 100.1 mA 157.2 mA 163.1 mA 235.2 mA O Temporal 4 520 Hz measured per ANSI/UL 2075 NOTES: • Operating temperature:32 to 120 F(0 to 49 C).The GHLF is not listed for outdoor use. • For nominal and peak current across ANSUUL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. RMS current ratings are per ANSUUL average RMS method. ANSUUL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units). For unfiltered FWR ratings,see installation manual. GHLF 24 VDC S E R I E NOTES: UL Listed • THIS APPLIANCE IS NOT RECOMMENDED FOR USE ON CODED OR Control Signal Signal PULSING SIGNALING CIRCUITS Panel S+ s- s- H+ H- S+ s+ s- H+ H- • THE FOUR PULSE TEMPORAL PATTERN(TEMPORAL 4)CAN ONLY BE Supervised 0 0 0 0 OBTAINED ON THIS PRODUCT WHEN USED IN CONJUNCTION WITH Signal Circuit THE GENTEX GTSM SYNCHRONIZATION MODULE 1 + ENO LINE • SEE GTSM CONTROL MODULE MANUAL(550-0632,MANUAL ISSUE RESISTOR DATE(02-01-15)FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. S GTSM MANUAL CAN BE OBTAINED AT WWW.GENTEX.COM/FIRE OR CALL GENTEX CORPORATION AT 1-800-436-8391. DOIMIW x o Lt LOCKING 0 0 o SCREW 0 " (optional) Cho H+ logo RED WIRES �- H! Q BLACK WIRES 6- � O o H- U a O o 00 NORMAL-LOUD o c �`f/ DECIBEL JUMPER. 0 0 FOR LOUD DECIBEL CEED INSTALL JUMPER. SLIDE ONTO BRACK Gentex Checkmate® Gentex Super-Slide® LOCKING Instant Voltage Verification: Mounting Bracket: SCREW It is often necessary to confirm the voltage drop Allows the installer to pre wire the system, (optional) along a line of devices.The access holes are test for system supervision,remove the provided in the back of the terminal block to signal head until occupancy,switch out allow the voltage to be measured directly without Gentex signals without changing removing the device.Typically this would be done mounting brackets and has locking edge at the end of the line to confirm design criteria. connector for snap-in-place installation. Most measurements will be taken using the S+ and S-locations although access is provided to other locations. NOTICE:CARE SHOULD BE TAKEN TO NOT qM SHORT THE TEST PROBES. Architect & Engineering Specifications The alarm horns shall be Gentex model GHLF.The appliance shall be listed with Underwriters Laboratories(ANSI/UL)for use with fire protective signaling systems (ANSI/UL 464) and with CAN/ULC S525 with intended use in fire alarm systems. The GHLF will produce a peak sound output of 88.3 dBA as measured in an anechoic chamber. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power at 24 VDC. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton Important Notice: GHLF-01 GENTEX These materials have been prepared Gentex Corporation Gentex')for informational purposes only,are O necessarily summary,and are not purported to serve as legall advice and should not used s such. Gentex makes no representations and warranties,express or implied,that these materials are complete and CORPORATION accurate,up-to-date,or in compliance with all relevant local,state and federal laws,regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to Fire Protection Products Group•www.gentex.com particular fact patterns.Each persons activities can differently affect the obligations that exist under applicable laws,regulations or rules.Therefore,these materials should be used only for informational 10985 Chicago Drive •Zeeland, Michigan 49464 purposes and should not be used as a substitute for seeking professional legal advice.Gentex will not be 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. CPOTTER MHT 1224 SERIES The Symbol of Protection LOW CURRENT MINI-HORN Features • Single unit is capable of 12 or 24 VDC determined by the input I voltage - Y I I IEI I Unit Dimensions:4.48"(11.38cm)high x 2.84"(7.21 cm)wide x F I 0.5"(1.27 cm)deep Jumper selectable temporal 3 or continuous tone I I I i Horn frequency is 3100Hz I I I I Terminal blocks(12 AWG to 18 AWG) • Low current consumption • Variety of mounting options for new construction and retrofit E applications • Synchronize using the AVSM Series control module • ANSUUL 464 listed for fire protective service • Textured finish high impact plastic faceplate,available in red or off-white Ordering Information Operating Temperature(indoor use only) Stock Number Model Number Model Designations 320 to 120OF(00 to 49°C) 4890001 MHT-1224R R=Red facepalte 4890002 MHT-1224W W=Off-White faceplate 4890003 MHT-1224PR P=Plain 4890004 MHT-1224PW SIGNALING U� LISTED Product includes a 5 year warranty Description The MHT-1224 Series mini-horn is a high quality remote The MHT-1224 can be used on the same sync circuit(AVSM audible signaling appliance that offers dependable remote annunciation. Series Control Module)as other Potter signals.The MHT-1224 Series The MHT-1224 is ideal for applications where a dependable audible is ANSUUL 464 listed for use with fire protective systems. alarm signal is required in applications such as hotels, dormitories, and apartments.The MHT-1224 is listed for use with both filtered and unfiltered power and a jumper is provided to select either temporal 3 or continuous tone. Architect&Engineering Specifactions The alarm horns shall be Potter model MHT-1224.The appliance shall be listed with Underwriters Laboratories(ANSUUL)for use with fire protective signaling systems(ANSUUL 464)and produce a peak sound output of 90dBA or greater as measured in an anechoic chamber.The appliance shall be of solid-state construction and be polarized to operate from 8-33VDC with a 22mA current drain at 24VDC.The appliance shall be provided with 2 terminals,and mount to a variety of single-gang back boxes. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830065-REV A PAGE 1 OF 2 06/13 (E) POTTER MHT 1224 SERIES ® The Symbol of Protection LOW CURRENT MINI-HORN Mini-Horn Wiring UL MHT-1221 MHT-I I 1151I I; WIRING DIAGRAM FOR DUAL CLASS B CIRCUITS WITH A SINGLE AVS"CONTROL MODULE CONTROI PANtI + — + SYNCODULAl10N F A C P MUrAIIE 1MT•t7H ANT•t!N h• lu M SIJI>f kV F.I 'NU IT I INr SIGnn•. tE51STDR CIRI'I ' EOI R SIGNAL CIRCUITS wr-Tti+ rrtfar 1_4Cf< B:-ALK Et,-ACK BLAf,R a., Wiring Diagram EOLR Mini-Horn Wiring Use a screwdriver to break the jumper for a continuous tone. O DO NOT BREAK m JUMPER IF TEMPORAL 3 TONE IS NEEDED. Horn Mode Minimum SPL at 10 Minimum SPL at 10 Reverberant dBA at 10 In Anechoic MHT-1224 Current Ratings feet per ANSI/UL feet per ANSFUL feet per ANSI/UL 464 Room dBA @ I 24 VDC 22 mA 464 at 24 VDC 464 at 12 VDC 10 ft. 24 VDC UL Max 18 mA Temporal 3 81 dBA 78 dBA 78-86 90 12 VDC UL Max 13 mA Continuous 86 dBA 1 83 dBA 78-86 90 NOTES:The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. 1 RMS current ratings are per ANSFUL average RMS method.ANSFUL max current is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units)(8-17 VDC for 12 VDC units).For strobes,the ANSFUL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units)(8 VDC for 12 VDC units).For audibles,the max current is usually at the maximum listed voltage.For unfiltered FAIR ratings,see installation manual. PRINTED IN USA MFG.#8830065-REV A PAGE 2 OF 2 06/13 GENTEX CORPORATION GOE OUTDOOR ENCLOSURE Applications A C C E S S O R I E S The Gentex GOE Outdoor Enclosure is ANSI/UL 464 listed for use in indoor and P A G E outdoor applications when used with the Gentex GEH Series horn and WGE Series strobe and horn/strobe. Standard Features • ANSI/UL 464 listed • Back box with side mount tabs • Made of clear Lexan°- providing maximum visibility and reliability • Unit Dimensions: 5.75" (14.61 cm) high x 4.75" (12.10 cm)wide x l •�,''- 4.18" (10.62 cm) deep • 3/4"conduit knockouts l'llll� • Reinforcement steel hardware --- R • Outdoor resistant gasket • Available in red or off-white GOE-R GOE-W GOELP OUTDOOR ENCLOSURE Applications The Gentex GOELP Low Profile Outdoor Enclosure that creates a surface mount look, is ANSI/UL 464 listed for use in indoor and outdoor applications when used with the Gentex GEH Series horn and WGE Series strobe and horn/strobe. Standard Features • ANSI/UL 464 listed • Back box with outdoor resistant seal for mounting to wall GOELP GOE • Made of clear Lexan°- providing maximum visibility and reliability • Unit Dimensions: 5.75" (14.61 cm) high x 4.75" (12.10 cm)wide x 3.25" (8.255 �+- cm) deep • 3/4"conduit knockouts • Reinforcement steel hardware • Outdoor resistant gasket • Available in red or off-white GOE AND GOELP NOTES: • Product does not meet ANSI/UL 1971 light distribution requirements • To allow for drainage, the seal on the bottom edge is not water tight GOELP-R GOELP-W GBLP OUTDOOR BACK BOX Applications f ►'� The Gentex GBLP Outdoor Back Box is constructed of durable plastic is ANSI/UL _ •, 464 listed for use indoor and outdoor applications when used with the WSSPK Series speaker and speaker/strobe. Gl Standard Features o' v • ANSI/UL 464 listed ,.. • 1/2"conduit knockouts with metal washer reinforcements i • Wiremold knockouts for 500, 700 Series and pendulum mount • Unit Dimensions: 6.20" (15.75 cm) square x 2.04" (5.18 cm) deep • Reinforcement steel hardware GBLP-R GBLP-W • Outdoor resistant gasket • Available in red or off-white ACCESSORIES PAGE GSB SURFACE BACK BOX Applications The Gentex GSB Surface Back Box is constructed of durable plastic and is fully compatible with the Commander' (GE)and Commander'(GE3) Series horns, strobes and horn/strobes. Standard Features • ANSI/UL listed for indoor use • 1/2" conduit knockouts with metal washer reinforcement • Wiremold knockouts for 500 and 700 Series • Unit Dimensions: 5.57" (14.15 cm) high x 4.55" (11.56 cm) wide x 1.47" (3.73 cm) deep • Screw heads hidden GSB-R • Available in red or off-white ALERT & AGENT BEZELS Applications The Gentex ALERT and AGENT bezels are constructed of durable plastic and is q fully compatible with the Commander (GE)and Commander' (GE3) Series horns, l strobes and horn/strobes. E Standard Features R T • Easy to install I • ALERT or AGENT wording on both sides of bezel • Available in red or off-white ALERT-W AGENT-R GCSB CEILING SURFACE BACK BOX Applications The Gentex GCSB Surface Back Box is constructed of durable plastic and is fully compatible with the Commander (GC) Series strobes and horn/strobes. Standard Features • ANSI/UL listed for indoor use • 1/2"conduit knockouts with metal washer reinforcement • Wiremold knockouts for 500, 700 Series and pendulum mount • Unit Dimensions: 6.2" (15.75 cm) round x 1.67" (4.24 cm) deep • Screw heads hidden • Available in red or off-white GCSB-R GCSB-W Important Notice: 551-0031-02 G E N T E X These materials have been prepared Gentex Corporation("Gentex")for informational purposes only,are necessarily summary,and arere not purported to servee as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these materials are complete and accurate,up-to-date,or in compliance with all relevant local,state and federal laws, CORPORATION regulations and rules. The materials do not address all legal considerations as there is inevitable Fire Protection Products Group•www.gentex.com uncertainty regarding interpretation of laws,regulations and rules and the application of such laws, regulations and rules to particular fact patterns. Each person's activities can differently affect the 10985 Chicago Drive •Zeeland, Michigan 49464 obligations that exist under applicable laws,regulations or rules. Therefore,these materials should be used only for informational purposes and should not be used as a substitute for seeking professional 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax legal advice. Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. S-24 & HS-24 CPOTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Features • 24VDC units have field selectable candela options of 15,30,60, 75,& 110 • Super-Slide®Bracket-Ease of Supervision Testing • Checkmate®-Instant Voltage Verification • Synchronize strobe and/or horn with AVSM Control Module • Prewire entire system,install mounting bracket,then install - signals f, _ — Documented lower installation and operating costs Input terminals accept 12 to 18 AWG Switch selection for high or low dBA Switch for chime,whoop,mechanical and 2400Hz tone Tamperproof re-entrant style grill R I I I I I I I I Switch for continuous or temporal 3 tone(not available on whoop tone) • Surface mount with the AVBB(Surface Mount Back Box) • Silence audible while visual appliance will remain flashing(for use in accepted jurisdictions) • Faceplate available in red or off-white Operating Temperature • 320F to 120OF(0°C to 49°C).The HS and S Series are not listed for outdoor use. Unit Dimensions • 5"(12.7 cm)high x 4.5"(11.43 cm)wide x 2.5"(6.35 cm)deep U� LISTED S3247 Description The S-24/HS-24 Series is a low profile strobe and horn/strobe This Series is shipped with a standard 4" metal mounting combination that offers dependable audible and visual alarms and the plate which incorporates the popular Super-Slide®feature that allows absolute lowest current available. the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without The S-24 & HS-24 Series 24VDC offers tamperproof field any screws showing. selectable candela options of 15,30,60,75,and 110 candela. The S-24/HS-24 also features the patented Checkmate® - The Strobe and Horn/Strobe offers a continuous or sync Instant Voltage Verification feature which allows the installer to check temporal three in 2400Hz and mechanical tone, a chime and whoop the voltage drop draw and match it to the blueprint. tone.All tones are easy for the professional to change in the field by the use of switches. The S-24&HS-24 Series appliances are ANSI/UL 464 and ANSI/TJL 1971, listed for use with fire protective systems and are The S-24 & HS-24 Series has a minimal operating current warranted for three years from date of purchase. and has a minimum flash rate of 1 Hz regardless of input voltage. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 1 OF 4 06/13 S-24 & HS-24 (E) POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Tone Switch Locations TONE SWITCH POSITION 3 4 5 ®o Mechanical Temporal 3 ON ON ON �® 1, Mechanical-Continuous OFF ON ON 2400Hz-Temporal 3 ON OFF ON ® S+ 2400Hz-Continuous OFF OFF ON S- Chime-Temporal 3 ON ON OFF -® H+ � Chime-Continuous I OFF ON OFF Whoop I ON OFF OFF Whoop OFF OFF OFF NOTE: • Switch Positions 1 and 2 in the OFF position to select isolated horn and strobe power inputs • Switch Position 6 ON=HIGH dBA • Switch Position 6 OFF=LOW dBA Super Slide®Mounting Bracket Checkmate®Instant Allows the installer to pre-wire Voltage Verification the system,test for system It is often necessary to confirm the voltage supervision,remove the signal drop along a line of devices.The access head until occupancy,switch holes are provided in the back of the out signals without terminal block to allow the voltage to be changing mounting brackets measured directly without removing the and has locking edge connector device.Typically,this would be done at the for snap-in-place installation. end of line to confirm design criteria.Most - measurements will be taken using the S+ and S-locations althouhg access is provided to other locations. NOTE:Care should be taken to not short the test probes. Candela selection slider switch. Depress center and slide switch to desire brightness level. r- T Break off pin and insert l S into hole at the bottom of .a the selector to lock candela setting.Signal must be removed from bracket and pin pushed forward from backside out of hole to change candela. To remove bezel,grip both sides of bezel and pull in a download and outward motion. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 2 OF 4 06/13 S-24 & HS-24 CF POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES S-24 24 VDC Selectable Candela,Low Profile Evacuation Strobe Model Part Nominal Candela Number Number Voltage (ANSI/UL 1971) S-24WR I 4890010 24 VDC 15,30,60,75, 110 S-24WW 4890011 24 VDC 15,30,60,75, 110 HS-24 24 VDC Selectable Candela,Low Profile Evacuation Horn/Strobe Model Part Nominal Candela Reverberant dBA at In Anechoic Room Number Number Voltage (ANSFUL 1971) 10 ft.,per ANSI/UL 464 dBA at 10 ft. HS-24WR 4890030 24 VDC 15,30,60,75, 110 62-82 100 HS-24WW 4890031 24 VDC 15,30,60,75, 110 62-82 100 S-24&HS-24 Product Strobe Current Ratings(mA) 24 VDC(16-33 Volts) Model Designations: W=Wall Mount Candela 24 VDC UL Maxi R=Red Faceplate W=White Faceplate 15 cd 30 mA 42 mA 30 cd 35 mA 58 mA All units are available in plain(no lettering). Plain units are non-returnable. 60 cd 66 mA 97 mA 75 cd 80 mA 116 mA ALERT bezel available for order. 110 cd 103 mA 161 mA ALERT bezel available for order. S-24&HS-24 Product Horn Current Ratings Horn Decibel Levels Horn Current Ratings Minimum SPL Minimum SPL Regulated 24 VDC Horn Mode at 10 ft.,per at 10 ft.,per Max.Operating @ ANSI/UL 464 ANSI/UL 464 High Setting(mA) (HIGH) (LOW) Temp 3 2400 Hz 78 dBA 71*dBA 28 mA Temp 3 Mechanical 76 dBA 70*dBA 25 mA Temp 3 Chime 70*dBA 66*dBA 15 mA Continuous 2400 Hz 81 dBA 74*dBA 28 mA Continuous Mechanical 80 dBA 72*dBA 25 mA Continuous Chime 70*dBA 66*dBA 15 mA Whoop 82 dBA 69*dBA 56 mA NOTES: • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified]) power,see installation manual. • Potter does nto recommend usign a coded or pulsing signaling circuit with any of our strobe products. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service.These settings are acceptable only for private mode fire alarm use.Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 3 OF 4 06/13 S-24 & HS-24 (E) POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Architect&Engineering Specifications The audible and/or visible signal shall be Potter S-24 strobe and Potter HS-24 horn/strobe Series or approved equal and shall be listed by Underwriters Laboratories,Inc.per ANSI/UL 1971 and/or ANSI/UL 464.The notification appliance shall also be listed with Factory Mutual Listing Service(FM)and the California State Fire Marshal(CSFM). The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater at 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage.The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control Control Panel signal signal Panel Signal Signal g+ S+ S- H+ H- S+ S+ S- H+ H- s+ S+ S- H+ H- S+ S+ S- H+ H. Supervised Supervised 0 B 0 B Signal Circuit Signal Circuit \ + \ + END LINE END OF LINE RESISTOR RESISTOR \ + 7D END OF LINE RESISTOR NOTES: • All strobes are designed to flash as specified with continuous applied voltage.Strobes should not be used on coded or pulsing signaling circuits.However,use of the Potter AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe,horn,and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION,REFERENCE AVSM CONTROL MODULE DATA SHEET(8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS.AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 4 OF 4 06/13 9 8 7 6 5 4 3 2FIRE PROTECT70N INC. 1 DEVICE INSTALLATION REQUIREMENTS PARK 77 APARTMENTSVICINITY MAP 1730 Gibson Road Everett,WA.98204 trvu awnr 425-290-9600800 CEILING MOUN NOT PERMITTED SMOKE/HEATJ+ Y(MINI) CEILING) HRE DAVID MOW DETECTOR �' AUDIO/VISUAL L�y E T B VISUAL DEVICES L A• 1OT H RE RM H� MAX _ 120904, HERE LEVEL III BUILDING 15 a.....wno�...ew.wo�un�a yafewav PERMITTED, D PALR P➢tE RBE we rlox HERE McDonalcr ��H„B n°mER NFPA no D e e 6w PFlD]E V W6 FIRE ALARM = A' fAr� %SNH 7YM —�r 000805173 0 f.6'D 2SR yM{ f6'AR 6PAa 64'An FIRE �NANUAL O v_ ROY L CATS tx n6t 71M PRONE PULL Aerospace Avenue NattAott Q�QPOTECjjOy JACK STATION nufactunng Tech FlNISHEII FLOOA 48-MAX ARLINGTON' WA y NFPA' y^' CFPS #1473 INSTALLATION NOTES CITY OF REDMOND DAaVIIDD MO W Fire Alarm Symbol Legend as#16-B-141cc° SYMBOL 1) Prior to calling for inspection,the installer shall provide DESCRIPTION PART NUMBER MFG CITY BACKBOX REQUIREMENTS MOUNTING REQUIREMENTS 204TH STREET N.E. documentation to the local AHJ stating that the system has been ® LCD REMOTE ANNUNCIATOR RA£075 POTTER 1 installed,tested,evaluated and confirmed to be in accordance with all ® DUAL INPUT CONTACT MODULE DCM4 POTTER 1 BBOX4,Standard backbox,4 °w governing codes and the approved plans.The Fire Alarm System - -'� AREA OF WORK C IJ PULL STATION SINGLE ACTION P31-1T POTTER 1 BBOX-2,Standard backbox,2 48'AFF = H n installer shall complete an NFPA72 Record of Completion(NFPA72 n W�s� 10.18.2.1.1). The completed Record of Completion shall be provided to SPRINKLER TAMPER BY OTHERS BY OTHERS BUILDING 15 U u m n C the AHJ inspector at the time of inspection(NFPA72 10.18.2.1.2.4). WATERFLOW BY OTHERS BVOTHERS BLDG.13 =/ i- -T} Z oc Q s - -•> o°O K 2) Instructions for the operating,testing and maintenance of the !,S) SMOKE,PHOTO.2-WIRE 2W-B SYS SENSOR 1 BBOX-2,Standard baclmox,2 o W N Q system,along with record drawings otherwise referred to as > a o a- ® SITE FACP LOCATED IN BUDDING 17 P300 POTTER E BLDG.12 o 1 ¢ >w w ("as-built")and equipment specifications shall be provided at an DID z z o approved location(NFPA72 10.18.2.3). 0 MINI HORN, MHT-1224W POTTER 12 BBOX-2, 2 STAFF BLDG.11 >IMpu ti m C w w r BLDG.14,' 3 p w�1 W a LF HORN LOW FREQUENCY,WH GENTEX GHLFW 23 BBOX-4,Standard backbox,4 82'AFF a,Q O 3) All systems and devices shall be installed and tested per the �" t w w c E manufactures listing and the authority having jurisdiction(NFPA72 ------- 3 c v a w 10.14.2.1).Label all device locations containing EOL resistors. Ps I INTELLIGENT IOAMP REMOTE POWER EXPANDER PSN-1000 POTTER 1 T I BLDG.17 y REVISION RECORD HORN/STROBE,2 WIRE,M-C,RED,WALL HS-24WR POTTER 1 BBOX-2,Standard backbox.2 82'AFF I Community _+ccu /� _ °' DATE/DESCRIPTION 4)FACP&all Remote Power Supplies REQUIRE a DEDICATED 120VAC Building, BLDG.9 20amp circuit.A notice placed in the FACP shall direct personnel to the OUTDOOR HORNISTROBE WEATHERPROOF ENCLOSURE GOELP POTTER i I L BLDG.10 �- - - location of the electrical panel that is supplying DEDICATED power to the system(NFPA72,Section 10.5.5.1). The DEDICATED circuit breaker I ;BLDG.8 that serves the fire alarm system shall be Labeled and Secured against BLDG.16 I d SHEET LIST J --. tampering with a RED breaker lockout(NFPA72,Section 10-5.5.2). I - FA 0.0 FA DETAILS -, '-BLDG.6 rBLDG.7_ 5 This property will have one FACP located in the Community Building. = BLDG.5- I. FA 1.0 FIRE ALARM P P T'tY Y 9• @ I __y _ -I) FA 2.0 RISER/CALCS --_ Each residential building will have a Remote Power Supply and a - --- ----- _- B Remote Fire Alarm Annunciator connected to the main FACP in the - Community Building.The FACP will monitor each buildings fire IN op - B sprinkler system via SLC,the occupant notification devices in each no no BLDG.1 a the building will only activated when a fire alarm device from that J specific building(waterflow,smoke detector,pull-station) is activated. -BLDG®2 BLDG.3 BLDG 4 6) Wall mounted strobes shall be placed 80"minimum to 96"maximum above floor level.(NFPA72 18.5.4.1&2).Wall mounted strobes shall be SITE PHASING PLAN sized in accordance with(NFPA72 Table 18.5.4.3.1(a).Ceiling mounted SYSTEM OUTPUTS strobes shall be placed and sized in accordance with(NFPA72 Table Required Fire Safety Control 18.5.4.3.1(b). Control Unit Annunciation cO1 / - 7) When MORE than two notification appliances are visible at the same .r``f� a° ;' SCALE: 1/8"=1' time whether they are in the same room or adjacent space within the y a °Q` field of view,the flash of those strobes shall be synchronized(NFPA72, ,.sue:`y y.�° ` DATE: 10/10/16 .n�2¢m c.e cm Section 18.5.4.3.2(3)&(4). °,y �d`"'$�� PROJECT NAME w.o> e m 7 a Q•O 8) Pull stations shall be placed between 42 and 48 inches above floor °zko o o°y a' CIRCUIT LINE TYPE Circuit Legend level.Devices shall be red in color ICC A117.1 309&NFPA 72 17.14.5 . ° y W Abbreviation Type Name ( ) F 4 f y C O P m ��'y ua �y o c u U #18/4 FPLR SLC-SIGNAL LINE CRKT Z Z Q 9) Outdoor strobes required for approaching Emergency Vehicles to a a a Q F� d,°,3 ----- W LO be located in the upper 25%of the building(at a serviceable height), ;4 y 3 9 A A #16/4 FPLR TWISTED PAIR NAC-NOTIFICATION CRKT UJ and to be clear) visible from the emergency vehicle approach path. d °F e F e> B B #18/4 FPLR SBUS I-- CD Q Z Y 9 Y PP P A A Z O 10 SYSTEM INPUTS Fire Alarm circuits to be installed/secured/terminated in accordance D EF~G QHI oJ ~ /� B C with NEC,NFPA 72,IFC and Local AHJ requirements&standards. 1 Manual Fire Alarm Boxes ♦ ♦ ♦ ♦♦ 1 Q 0 1-:3 2 Smoke Detectors ♦ ♦ ♦ ♦♦ 2 n :3 0 J 11)The means of communication to the central stations for the fire 3 W Sprinkler ♦ ♦ ♦♦♦♦ 3 Fire Alarm Device Numbering Y cV IX 4 Sprinkler Control Valve ♦ - ♦ - 4 N Q alarms stem is to be provided b a Potter UD-1000 DACT as per Ian. Q y P y P P 5 Fire Alarm AC Power Failure ♦ - ♦ 5 (SLC)ADDRESSABLE DEVICES NOTIFICATION DEVICES System requires 2 x POTS telephone lines,1 of these lines is required 6 Fire Alarm System Low Battery ♦ ♦ 6 d to be DEDICATED to the FACP.The FACP is located in building 17. 7 Open Circuit ♦ ♦ 7 CIRCUIT CIRCUIT 8 Ground Fault ♦ ♦ 8 F �DEVICEADDRESS DEVICE 12)All building linking conduit&wiring to be provided/installed by 9 Notification Appliance pliance Circuit Short ♦ ♦ 9 ` CANDELA— ' SHEET DESCRIPTION (S) 10 Remote Pow sLc•#x# Power Supply Trouble - - ♦ ♦ - 10 ` l others. a a c D E F G H I J FIRE ALARM OPERATIONAL MATRIX SIG#•### ##CD SMOKE DETECTOR SHOWN AS EXAMPLE DETAILS SHEET NUMBER FA 0.0 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 FIRE PROTECTION INC. 1730 Gibson Road Everett,WA.98204 425-290-9600 DAVID MOW m _ _, 120904 - - LEVEL III D UO.11 n1 NR UNITD-9 UNIT 0.10 r--- 3 I D slca•aoe I B/{FPLR H UWD-12 IN THE RIBERROOM.. NFpA rI- 000805173 I �❑ ROY L CATS n L I 1-7 'rt� .. - b N�• 5 #1473 L 1 q I R/ I I E ENT - ENTRY I I ENTRY I -I SIG1009-. I I —__ I _ _ DN DN ` I CITY VI REDMOND slca.14 E�.jLL.I slcsa+a Ir D VI AD o MwOaW a c I De#16-B-141co 1 1 I I O W �? W _ W oUT K C 2 N z F 6 d Q U = 3000� ,7 Ir 3RD FLOOR �ZOw.x N aoYa's 3OCOca p�Yw�w OmzEO Y W Ou.mY mmww6K 2 p r U w 614THHNISBIL TO THE FAC 3Y�<R_O LOCATED IN BUILDING 17 i �¢�w w^'C a DUN—,aw z REVISION RECORD F DATE/DESCRIPTION z Sze, �F1612 THHN(SLC)TO THE FACP C LOCATED IN BUILDING 17 I I' _ - SHEET LIST 1 Ts Fs FA 0.0 FA DETAILS 1 Z 20^ zN,•oo, _ _ II FA 1.0 FIRE ALARM cam— ENLARGED — I I UNRD-7 FA 2.0 RISERICALCS UN RISER ROOM slG,.00x UNIT D3 �UNIT � UNIT D-2 r— UNIT DS siGaocy UNIT D-6 �- t t UNITD� S IN THE RI ER TROOM B I -----" -- -�s,G,wae uNRw I YY A I 11Ti� I`R fIG2.o— AJ t �7 � O II II- ------------ - ____ __ ,. .�� sTNFU I I STAIR/ ;' ��-- ------- r slaw j I___ STAIR/ J I,�I I_ } SCALE:1/8"=1' t I ENTRY I ENTRY I I DATE: 1Dt1D/16 I I ENTRY I ENTRY I I I I—`�� G.o I up t-6 up I _H soo, PROJECT NAME 16/4 FPLR SIG 1 TO THE Gz ma ^4 s SIG— slc+•o+a IN THE RISER ROOM L I �� Z 51G. 81GI•WI Blp,-003 EOI NGC SIGx Ott .� I SIG2003 I GIG09� EaL we SIGt-011 SIGI-0,0 it .,0 I W LU I I� � N V Q Z t Q Z O A — I. H UP UP noco r j ^ Z swaooa m CD 1 ST FLOOR N 2ND FLOOR N a N a 0- SHEET DESCRIPTION FIRE ALARM SHEET NUMBER FA 1 .0 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 HRE PROTECTION INC- 1730 Gibson Road Everett,WA.96204 425-290-9600 DAVID MOW Battery Calculations for Panel:PS BUILDING 15 ® v Part No:PSN-10D0-INTELLIGENT 10AMP REMOTE POWER EXPANDER Part No. Qty. Description Standby Total Standby Alarm Total Alarm 120904, Panel Equipment LEVEL III PSN-1000 MB 1 10AMP POWER EXPANDER MB 75.000OmA 75.000OmA 215.0000mA 215.0000mA Total Panel alloy 75.0000nA Total Panel Alarm 215.03DOmA Peripheral Devices 2W-B 1 SMOKE,PHOTO,2-WIRE(Initiating) 0.01IXMnA 0.0100mA 6.5000mA 6.5000mA P31-IT 1 PULL STATION SINGLE ACTION(Initiating) 0.0000mA 0.0000rrA O.000OmA 0. MKT-1224W 12 MINI HORN,WH(Notification) 0.000OnA 0.0000muk 22.000OmA 264.00013mA D GHLFW 23 HORN LOW FREQUENCY.WH(Notification) O.0000mA 0.0000mA 99.4000mA2286.2000mA NFPA HS-24WR 1 HORN/STROBE,2 WIRE,M-C,RED,WALL(Notification) O.000OmA O.0000mA 186.000OmA 188.0000.A Tolel Peripheral Slby O.Ot00mA Total Periph Alarm 2742.7000 000805173 Total Standby Amps 75.0100mA Total Alarm Amps 2957.7000.A ROY L CATS Standby time:24 His 1.SM Q-SOTECl @��^�y Alarm time:5 Min 0.246 w ■■,��`,, ■■, Battery requirement 2.047MM Compensation Factors-Standby:1.2 Alarm:1.2 Requirement with compensation: 2.458M b NFRW C and y5 CFPB #1473 Circuit Calculations Panel:PS Card:00 Circuit:SIG1 Circuit Calculations Panel:PS Card:00 Circuit:SIG2 Circuit Calculations Panel:PS Card(00 Circuit:SIG3 �& CircuitName:SIG CIrcuhName:SIG2 CircuitName:SIG3 CITY OF REDMOND Circuit Type:Notification Terminal Voltage:20.4V:DC Amperage:3.lXg0A Circuit Type:Notification Terminal Voltage:20.4V:DC Amperage:3.0000A Circuit Type:Notification Terminal Voltage:20.4V:DC Amperage:3.0000A DAVID MOW Cable:16/4C TWISTED FPLR#16 Cable:16/4C TWISTED FPLR#16 Cable:16/4C TWISTED FPLR#16 Calculations based on Running Total Length. Calculations based on Running Total Length. Calculations based on Running Total Length. na#16-B-141co Design Criteria:Ambient temperature:167'F Max.operating voltage drop:15% Design Criteria:Ambient temperature:1676F Max.operating voltage drop:15% Design Criteria:Ambient temperature:167'F Max.operating voltage drop:15% Device Part No Appliance Desc Distance Current Vottage Vottage Drop Device Part No Appliance Desc Distance Current Voltage Voltage Drop Device Part No Appliance Desc Distance Current Voltage Voltage Drop PSN-1000 Panel 20AV PSW1000 Panel 20AV PSN-1000 Panel 20.4V p 001 GHLFW HORN LOW FREQUENCY,WH 59 99.4000nA 19,861 TV (0.538MI 001 MHT-1224W MINI HORN,WH 17 22.0000mA 202745 (0.1255V)l 001 GHLFW HORN LOW FREQUENCY,WH 58'-0 99.4000mA 20.0118V (0.3862V) w C 002 MHT-1224W MINI HORN,WH 91-0 22.0000mA 19.7641 (0.0777V) 002 GHLFW HORN LOW FREQUENCY,WH 10' 99.4000.A 20.1721 (0.1024V) 002 MHT-1224W MINI HORN,WH 9-0 22.0000mA 19.977 (0.0343V) - 003 GHLFW HORN LOW FREQUENCY,WH 10' 99.400DmA 19. (0.0842V) 003 GHLFVV HORN LOW FREQUENCY,WH 7-0 99.4000mA 20.1 (0.01 GHLFW HORN LOW FREQUENCY,WH 17-0 99.40DOmA 19.9114V (00661V) -ac w�n W 004 GHLFW HORN LOW FREQUENCY,WH V 99.400DmA 19.677 (0.0224V) D04 HS-24WR HORN/STROBE,2 WIRE,M-C,RED,WALL,IIDCD IY 186.0000mA 20.045 (0.1079V) 004 GHLFW HORN LOW FREQUENCY,WH 44'-0 99.4000mA 19.7119 (0.1995V) w m V m K C DD5 GHLFW HORN LOW FREQUENCY,WH 49-0 99.4000.1A 19.3601 (0.3174V) 005 GHLFW HORN LOW FREQUENCY,WH 2D 99.4000mA 19.9161 (0.1296V) 005 MHT-1224W MINI HORN,WH 36-0 22.000OMA 19.583 (0.1282V) 2 u y 6 to DOG MHT-1224W MINI HORN,WH 3-P 22. 19.1 (0.2037V) ON MHT-1224W MINI HORN,WH 36' 22.000OmA 19.7179 (0.1982V) GHLFW HORN LOW FREQUENCY,WH 9-0 99ADOOmA 1956M (0.020114 Q U = 007 GHLFW HORN LOW FREQUENCY,WH 9-0 99.40ODMA 19.12 (0.0317V) 0D7 GHLFW HORN LOW FREQUENCY,WH 5 99.4000mA 19.6862 (0.0317V) 007 MHT-1224W MINI HORN,WH 37- 22.000OmA 19.487 (0.076V) 0 O U ir DDB HT-1224W MINI HORN,WH W 22.000OmA 18.9951 (OA296V) U08MHT-1224W MINI HORN,WH 1 37 22.0000mA 19. (0.1382V) 0081 GHLFW HORN LOW FREQUENCY,WH V-0 99.4000mA 19.47 (0.013V) G O a a N 009 GHLFW HORN LOW FREQUENCY,WH 6' 99. 18.97 (0.0246V) 009 GHLFW HORN LOW FREQUENCY,WH 8' 99,1000.A 19.5233 (0.0246V) MKT-1224W MINI HORN,WH 3g'-0 22c000.A 19.439V (0.0356� 2 O w H a 010 GHLFW HORN LOW FREQUENCY,WH - 99. 18.83 (D.1378V) 010 GHLFW HORN LOW FREQUENCY,WH 24' 99A000MA 19.4482 (0.07 01 GHLFW HORN LOW FREQUENCY,WH V-0 99.40DOmA 19.4332V (0.0058V) a O a O J 011 GHLFW HORN LOW FREQUENCY,WH 2'-0 99. 18. (0.0043V) O O m K O 011 GKLFW HORN LOW FREQUENCY,WH 7 99.4000mA 19. (0.0043V) 236-0 684A000mA t IX O ri N 012 HT-1224W MINI HORN,WH 15 D 22.000OInA 18b1 (0.0178V) 012 MHT-1224W MINI HORN,WH 15 22. 19.4261 (0.0178V) Total CurterR 664.4000nIA m C ly H 013 GHLFW HORN LOW FREQUENCY,WH 6-0 99A000rnA 18.805 (0.0049V) 013 GHLFW HORN LOW FREQUENCY,WH 5 99.400D.A 19.4212 (0.0049V) (Toml VDrop Peroerit4.74%) Totel Voltage Drap:0.9B68V Z F w 272' 982.6000 3 H- 183' 1(169.2000mA a Total Current:982.60DOmA }>a O (Total VDmp Percent7.82%) Total Votage Drop,1.5943V Total Current:Drop 0.9788V ~ra lu tl C 6 (Total VDrop Percent:4.t1096) Total Voltage Drop:09788V O O w N�a w REVISION RECORD DATE/DESCRIPTION SHEET LIST FA 0.0 FA DETAILS FA 1.0 FIRE ALARM FA 2.0 RISER/CALCS B g LF H LF H LF H F11111 LF H LF SCALE: 1/8"=1' L1 H LF LF LF H LF H LF floca LF LF H F DATE: 10/10/16 PROJECT NAME o PS BLDG 15 LF LF LF LF LF L,yF LF LF LF c)1`� 1- W H P H Sy H ii & H & J Z Q TS F- it n Q Z A FACP Fs Z = O 1 XDEDICATED 120-1 20AMP IN Me ..h'On ll I' A CIRCUIT IS REQUIRED BLDG 17 ANN Q t` Z Ym (V X (D Q 14 SHEET DESCRIPTION FIRE ALARM CALCS/RISER SHEET NUMBER FA 2.0 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 FIRE PROTECTION INC. 1730 Gibson Road Everett 98204 425-290-90-9800 INSTALLATION NOTES ONDUIT WITH �g L D G. 1 � \ DAVID MOW 1 CONDUIT ROUTES ARE FOR REFERENCE, EXACT 6x THHN#16 1 x RED,1 x BLACK ROUTE TO BE DETERMINED BY THE ELECTRICIAN. 1 x BLUE,1 x WHITE \ BUILDING LINKING MUST BE DONE AS SHOWN FOR 1 xGREEN 1 xYELLOW \ A CLASS A LOOP AND PROJECT PHASING. 120904, \ \ / LEVEL III p 2)JUNCTION BOXES SHOWN ARE TO BE LOCATED IN THE FIRE SPRINKLER RISER ROOM OF EACH / \ \ BLDG 12 �� �� n BUILDING OR ON THE EXTERIOR WALL OF EACH . SPRINKLER RISER ROOM WITH A MINIMUM OF 16 J \\ \\ 4 f BLDG. 11 _ NFPA AWG WIRE AS SHOWN. JUNCTION BOX LOCATIONS 000sos173 SHOWN ARE BASED ON INDIVIDUAL BUILDING \ ROYL CATS ONDUIT WITH ONDUIT WITH Qaoreo> PLANS. i x THHN#16 x THHN#16 1 x RED 1 x BLACK 1 x RED,1 x BLACK ONDUIT WITH w 1 x BLUE,1 x WHITE 2 X THHN#16 L'1►J BLDG. 14 1XBLUE,IXWHITE 3) BUILDING LINKING CONDUITS/WIRING TO BE RUN 1 x GREEN,1 x YELLOW � 1x GREEN,1xYELLOW �' ,J 2xRED,2xBLAC b�JNFPAyyc TO A GUTTER IN THE ELECTRICAL/MECHANICAL `� \ 2x BLUE,2x WHIT E CFPS ROOM IN BUILDING 17 THE SITE FACP IS LOCATED 2x GREEN,2xYELLOW #1473 IN BUILDING 17). \\ \� / I I I I �& 4 ALL FIRE SPRINKLER RISER ROOMS REQUIRE 1 x ONDUIT WITH I I I CITY OF REbMOND DEDICATED 120VAC 20AMP CIRCUIT FOR EACH \ xTHHN#16 ONDUITWITH - C .,abnswo MO o BLDG. 17 xTHHN#16 1 x RED,1 z BLACK o.#16-B-141 w REMOTE POWER SUPPLY. 1 x DEDICATED 120VAC J- �� 1 x BLUE,1 x WHITE 1 x RED,1 x BLACK 20AMP CIRCUIT IS REQUIRED AT THE MAIN FACP IN \, 1 xGREEN,1 xYELLOW 1 x BLUE,1 x WHITE I 1 1 1 cn Community w 1 x GREEN,1 x YELLOW Q BUILDING 17 ( SEE FIRE ALARM DRAWINGS FOR oNDu1TWITH GEC ROOM II I T. d� w BUILDING FIRE ALARM DETAILS). -ONDUIT WITH xTHHN#16 Building �. _��� W x THHN#16 1 x RED,1 x BLACK G —m W N y w,oVm 'wx 1 x RED,1 x BLACK 1 x BLUE,1 x WHITE y � z#H a C 1 x BLUE,1 x WHITE t x GREEN,1 x YELLOW 1X GREEN,IX YELL OW oo� pS2 -BLD . 15� �� BLDG. 9 2 CI_ FilEXTERIOR OUTDOOR RATED JUNCTION BOX `� \ ® J ,,. _ __ N p o m a ONDUIT WITH __�� 1 a W p W a. x THHN#16 \ _ � , W 3o� a ` W 1 x RED,1 x BLACK N >a o a ELEC.GUTTER TO BE LOCATED IN ELEC RM OF BUILDING 17 \ J w La;; z a 1 x BLUE,1 x WHITE ����_ p O w N M w 1 x GREEN,1 x YELLOW \ g L D G. 10 ONDUIT TH REVISION RECORD \ WI x THHN M6 ^ DATE/DESCRIPTION 1 x RED,1 x BLACK {+� ONDUIT WITH 1 x BLUE,1 x WHITE x THHN ON WITH 1 x GREEN,1 x YEL I x LOW BLDG. 8 1 x RED, x BLACK x THHNHHN#16 r ` 1 x BLUE,1 x WHITE 1 x RED,1 x BLACKSHEET LIST r 1 x GREEN,1 x YELLOW 1 x BLUE,1 x WHITE 1 �.nnnnn�I I ' 1 x GREEN,1 x YELLOW Wuu BLDG. 16 N �� ONDUIT WITH o x THHN#16 B WI!® — 's—� f 1 x RED,1 x BLACK N J 1 x GREEN,1'xYETLLOW B _ BLDG. 5 ; J BLDG. 6, J BLDG. 7 a � N — ONDUIT WITH ONDUIT WITH x THHN#16 tu x THHN#16 1 x RED,1 x BLACK (� = 1 x RED,1 x BLACK _ t x BLUE 1 x WHITE \1 1 x BLUE,1 x WHITE 1 x GREEN,1 x YELLOW DATE: 10/10/16 ONDUITXTHH WITH 1 xGREEN 1 xYELLO e J� PROJECT NAME 2 X THHN#16 a 2 x RED,2 x BLACK 2 x BLUE,2 x WHITE 2 x GREEN,2 x YELLOW ~ LU I W Z Q BLDG. 1 ��BLDG. 2 BLDG. 3_ BLDG. 4 Q Z A Boa p� N ONDUIT WITH ONDUIT WITH d x THHN#16 x THHN#16 t x RED,1 x BLACK 1 x RED,1 x BLACK 1 x BLUE,1 x WHITE 1 x BLUE 1 x WHITE 1 x GREEN 1 xYELLOW 1 x GREEN,1 x YELLOW SHEET DESCRIPTION N FIRE ALARM SITE BUILDING 41 LINKING PLAN SITE BLDG LINKING PLAN E SHEET NUMBER 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 \ FIRE ALARM ` PERMIT APPLICATION �iI1 CK�O Department of Community & Economic Development City of Arlington • 18204 59th Ave NE •WA 98223 • Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO, INCLUDE SPECIFICATION SHEETS,WIRING DIAGRAMS, (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) ✓❑ New Fire Alarm ❑ Fire Alarm Alteration/Addition Project Address: 20201 77TH AVE NE BUILDING 15 Parcel ID#: 0082910000103-109 Njmber of Zones lPanels:2 Building Area (Sq Ft,E: 21000 Valuation: 3500 Owner: WD ARLINGTON INVESTMENTS Phone Number: 425 290 9600 Address: 1020 WEST CASINO C ty:EVERETT State: WA Z p Code: 98204 Contact Person:DAVID MOW Phone Number: 425 290 9600 Cell Phone: 425 290 9600 Livia : DAVID@FPISEATTLE.COM Address: 1730 GIBSON ROAD C ty:EVERETT State:WA Z p Code: 98204 Contractor: FIRE PROTECTION INC Phone Number: 425 290 9600 Address: 1730 GIBSON ROAD City: EVERETT State: WA Z p Code:98204 Contractor's License Number: FIREPI*021ML Expiration:7/31/17 Contact Person: DAVID MOW Email: DAVID@FPISEATTLE.COM Electrical Contractor: FIRE PROTECTION INC Phone Number:4252909600 1730 GIBSON ROAD EVERETT WA 98204 Addresses C ty: State: Zip Code: Contractor's License Number:FIREPI*021ML Expiration:7/31/17 I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described ro wqu_e-ar-nrrianWith the laws,rules and regulations of the State of Washington. 10/24/2016 Applicants Signature Date DAVID MOW Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received WEB Form—130 Page 1 of 1 6/16LP CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 , PHONE; (360) 403-3551 BUILDING PERMIT Address:20227 77th Avenue NE,#15 Permit#: 1191 Parcel#:00829100000103 Valuation:3500.00 OWNER APPLICANT CONTRACTOR Name:WD ARLINGTON INVESTMENT LLC Name:Fire Protection,Inc. Name:FIRE PROTECTION INC Address: 1020 WEST CASINO RD Address:1730 Gibson Road Address: 1730 Gibson Rd City,State Zip:EVERETT,WA 98204 City,State Zip:Everett,WA 98204 City,State Zip:Everett,WA 98204 Phone: Phone:425-290-9600 Phone:425-290-9600 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2015 STORIES: 3 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCl IOARC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the Arlingto must be reported on your sales tax return form and coded C' of Arlin on#3101. Signature el Print Name Date Released / Date CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZE ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount Total Due: $0.00 Total Payment: $0.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon .. o 0 0 O 0 o 0 0 E ds v3 EACa > > O Q C� az a ° Qcn Z U N O W Q N Ow Z F- z w w ° F� e a o Ey F. z o a e w W a d �p w j d y e do ti M LL W +..' N ��.. � N a ~ � R C O p Z O E v c , O `d E E M d ro Z Q U a z vF U cD p FU e° Z a z 0 O z y 0 > OO c¢j W > a O> pU �o ►� � � � U Q z U U a �o ¢ z a a zdUa o 0 o a z � r�~� o 003 0 - � a s ° a° 0-4• 3 C7 x O u: E O a ] a o a 0 W V U O a W A u eu oar �0NH Hw ❑ V 3 a nd a M N cv W C7 oo >, Ln o W pa p 00 v O_UZ e° G E " o d > � z � z z - CIAz Q U a W Q O aQ � Suz, a 03z o Ua H CnOz � dawi o � �< b9 a 0 0 Q� aQ = >Iy M z 3 Q U \ Z C E F- oNo W U U W W A a Uaalza O Yoa y [1 z z 3 O w �, � a �o o � � 4t O W E °w V r.y 3 z 'n z 'A u o z a a d o U �- Ow� 0O W e y0 o C7 F v adz �W z W V V C) j O O o u a ` 1 0 oNo aj ccd44 a ~ N WWI O U ¢ n 0 W F� QU dU V W � p �o �1l 7 � b zQU � .a O a O G1 m Qxp da z ¢' va ~ U d � 'I+ °°4 SAC . ■ XX c wc o § . $ ƒ ) ) % \§w ` \ \ \ \ z§w 2 j « m /C) ' $ 000 m { sst y § . � k LO E ) ) ` k 2 o B 7 0 \ a ) @ ' 3 \ \ \ k \ § � _/ E / k } . \ 0 2 t 2 m k ) $ 0 E s / t / § k § \ e § / k ] \ \ w c f = E n < e e ■ . 0. e . . ■ , e e ■ o ' E a ■ § ® 0 e , e ■ e . k = % F ■ . , . m % ° § z z a § ' 2 2 7 \ ' ® ■ u « « 2 - e 2 ® , Q ' 0 ` ■ 2 d ■ ema , & � § § e ® . ■ e eee & - e & IL s E & w . 7 E / / C 2 z ' 2 ■ jww . a � � §>2 2 . (L (L CD co § § \ §° ; - E ' � \ §$/ % MEM- \�\ . ` § \ \ \ uC) ' o aa � - - ,, r � 0 z LU 0 MO �. as _ rL M c O1oCD w V CL = r�i CF N 8 � C? m a. a O O N O N p N O O P CV) 0tD 00 Co LLto w Q r-I t0 00 to 00 W 00 O 00 p U m It N W a O C1 Qt OlQQ C1 Q1 q Ol Oq y O Z0 CD > > i7 O C1 N c� N (� N C� L E M a V W � r-I ui N O a" Z d C1 m Ln Ln _n Ln _a u1 a _a — Q C W O a Cl) co N �N N N \ N \ 41 O J W Z O _ .. .. .. aria V� 0 E p ro a� m `m m a) m Q �`� a W cach > > a 3 0 E E Q c E `c� zm a A z z c� Z o ° z' o Sp W a a oL C Q CO a U) w a cn w � o o of a �aW w w �� Q W.QX Ln Ln 75 IL 'Z U� ~p o a.U- a O � o W Q ' a' 0_j to% N COw a s E LL a w W a owc o w a m w ° w w ° w �, � o } c�v v c7 Q ern w w w w Y_o oNc 00 O U i '� E E a o �i E — 3 LL Z U w v U w U �, W t9 m ° c 0. vQ zaWO id �z Z 00 coz g a0F0 w z z ,� o 0 2� HQ Q z w V NN 0 NN �; O Z w w z 2 F N E > t� 0— IL a s w ° ° w p 0a LL°C Z ~ > z a Q 3' bz WFd z R ? F o 0 LL,. 0 �L 0 E"aO o U a to z z a� U a a • n. aO N to > rn m z > wtn z $ a c 0 0 Ln Ln zLL51 Q N [L m � Q m v ro 0i i Q a` O� a C7 CL N d J 7 ° L W c ° 'o— c � �? � a2FCW Q NO O r. m LL n1 c `O T4; j" MW —J N Q o N om r-I Wit; O �I v a.IL .«- 0 5 a $ a d U�in $ � 4 JCL 2W A o 3C o � c c c .2 a 0 € m z O < v U ¢ t) ¢ u 0 w ¢ cU _ Q � a 3 •4r1 01 Id U H N --A, d W 'rl 0 0 dI �0+ .O w rI 0 Q) G-A.4a N A it 'd N N MM 14111 0 0 r•I b1 'd b1 'd 0 V -rl •rl r-I 0) 0 FM (D F- A U ro 0 01 0 r-1 A ro ro N b+ N o A m O 0 z 'd v d -rl 0 -rl •r1 N 01 Cl 04 N 0) A H -10 H 0 'd 'd Id '0 � 0 a Id -rl 'd 0 ri 0 11 ro H 0 -1 r-I u -1 A N -1 'd U 0 r•I N V1 O 0) rl -rl 0 •rl O S ro 0 0 H O W N ro a o w 12,10 O $ N -rl d r-I O G) 'd '1 1. 0) r1 0 H A w -rl U 01 N 'd A 11 V a 01 H A d 0) 'Ji N E) 11 H 'd 01 0 a 01 0 a s •rl 0 0 N $ A A A � 4) D O u U N U ,� rl H U N 0 Id o b1 U b1 4-) w ro Cl d r 1C �1 Ida 01 H D 0 0 0) 11 N M 11 0 0 C] ro 'd b1 a W 0 rl W 11 'd rl ro rl +1 01 ro H O •rl 11 H 0) 0 0 0 ® N $ 41 ro 01 A,' 0 rl 'd ro A A O N 01 z U 0 0 -A 01 -rl O 0 01 'd u U r-I D Q A 0) — d N Id 0 rl •rl 0 Cl 0 00 N H 0 0 u N H b+ 11 A 0 U H N d +1 ((�� rl 0) 'd H N rl 01 0! 0 rl •rl rl U ro N 0 A U 0 +� S O U 11 A 0 'd 0 A 0 A CJ 0 r-IrlN Cl Id 001 >1 N r-I � 'd H 01 N � r-I 01 H r-I H U 0 •r) >1 N ro H w H H U p uxro 00 H0 Id 1 � 0 H N rl l 'd {" 0 r-I A M r-I VEE4 : A Id .k 1!) Vl A p H 14 P4 0 0 01 O 14 A ri N H A,' N O W N V � ro 14 O rl ro 0 01 H 0 ro 01 a N •r4 • -r'rl w 0 9 �N Ind u � It9A9N11 °l 0 o a0 b� ,0 r•1 'J1 0 01 :3 1 O rl •rl 10 N 0 •H H W $ O U 0 1 �+ i1 r•I H O 14 0 11 •-1 () H $ 11 0, id N N z 11 W Id 04 N •� -rl a $ r-I I•1 a.1 •r) V >1 ` 01 w V' W $ a ii O N r� ro a N 0 N 0 N d) 0 N A' 11 O1 N b � aG 0 :3 'd w A A Al -AU 0) N U 0 r-I 0 +1 a a o ao N N 0 N U 04 a -rl ro 0 0) rl A 11 W W ro H O •� V3 H w b1 11 u w -rl 1 .0 1 +� $ i 0 z 1e� W o 0 11 N N r•1 O p 0 b+ H 11 H O Id a h f Val 0 -rl 00 0 Id r1 0 00 0 0 0) O r•I rl 11 'd rower o0 rroi d' $ 0 AV � � � '60 ppox p, +P► a4 !V 1y 14 'rl a 'd U O V1 +1 O H 0) 0 01 H Id I a H 01 01 w •fir O 11 fi d) rl rl b U H 0 O -rl N 11 H 0 ro -rl a 0 0 .0 11 E) (n 44 d) A 0 A 11 11 M 0 H ro -1 d 01 01 A ro 11 H - w A N 01 4••1 $ 0 V 0 rl Vl 0 •rl V A U 11 H 0 11 01 p� 0 w +1 01 D 9 4) N O H 0 u $ 01 $ O ro rl ro •rl ro 0 Q d A V b1 w .7 �i pp H ro at ar b o N U �1 D C�' Ci 11 p, at o o cn 11 1 0 u Z WN Id rl AH0 0 0HA Id 0) 0 0 a01CU u �" 0 01 -rl 0 w N �'1 H `•' �1 11 0) rl ro 01 rl ro 41 .�: 'd rl rl N N b1 41 11 H W H 4 Z r a 1` 1"i H p M -rl 1 0 a•1 1 'd 0 d ITi a H � W H 0) 'd H 01 'd U 'd V 0 -rl -rl r'1 N 01 -rl 0 �••� 0) ro Q ao 'd 'd r1 +1 u a tr o o 'd H ro +1 11 �+ O H U p N ro A,1 01 b1 A d $ A 0 w O 0 0 rl rl 0) H N 0l .0 W 11 r•1 V O 'd O N U rl 0 ro d H •rl A �1 Q 0 b 0 rl a * QI� p Z O •rl 0) 11 y 01 ` 'd b1 41 0 ro 1"1 W H r•1 H 41 41 0 0 H r'V OD O H 'd N 0 9 0) b1 .0 It H O 04D U H N 0 H N Z U O a O E•-I U H 0 0011 ,lr' O H O A A Id A O d Ill $ H WW 0 A,' 11 0) 0 w IS uh 0 rl H IdH rl H d 'd a 0, W N O rl Ida rl 0 O a t N p4 01 d H N rM.-rl - 41 A H 0 N 0) -rl >1 .0 rl H 0 A H b1 Q O Z A ro U >1 • 0 014 A a 'd 0 ` b1 Id Id N O z N N w [-1 11 „ W 0 rl Id N �+ O 'd 14 1` • 0) 0 U O 'd 0 rl A H A 0 a a s a cc 04 cl o ` S ra H H 0 id o b1 0 1` �+ -rl 0 s q 0 � � W H O •r•I N 3 �C A -rl .-. 0 11 a ro •rl 0 Id 'd O �1� a +1 'd 0) O 1•a H N N r-I .� ly W b+ �" 01 b1 b1 $ V U b1 A V H •rl 'd -rl pq w 0 01 11 a1 U H Id O O 'd 0 1° H 0 0 tT 0 A 0 4J �+ a 0 A 0 N H A A V rl l� W r W C1 e�.., 01 0) A A rl rl 0 Id 0) 41 -rl ro 1d W 0 d ro 'd A 1� 11 01 W H $ � W N W N O N 0 'd 0 'd 'd rl 'd A 'd -rl a z 01 A D •r1 A 1n ITi � rl H H Ca Id Id HA H H A 0 A U H V d $4 rl 0 •ri r, H 0) d7 CA m r 1eo �j 01 U -rl ro 11 A A 0 01 N 0 A A U 11 11 01 V 0 'd V1 $4 1•f O W at F V Qi a rii A N 04 M A A H $4 0" A A 0 p1 0 EA1 IIdd A4 A H Id $41Ul o FH1 113 nx Ct7 11 � roa, nbro 0 a rto 0 pe to n HH roa ww m8aIDIDow000r t4 HA 4 ri 0 0 a Cr• 0 " " rt w a ro w rtrrr x rd C4 M 0 1- ID 0 rt In F'• m r r• 10 O H rh P. n r a n N• 0 0 hn r N• pt fh � r� o rta rtwo ao ri w1 r roH y [ 'bD' O row r 0 IDW PH no rtID n a II• 0 tiw r0 o ° � � ror°i, � rta rtt� � n H H n � � noa r ri 0 aID 0 w0w a vN a 0ri .. ri0a0aP. 0ra H C o W w a k m a rt a p ao n' a 0 O H 00 w H a � C: �7 0 0 4 N p rt r n rt w n rt H tD o p. a p r w a w tD H �"1 0 H. w � rt r 0 a 0 o ri rt b M P• n ro 0 � U) w m x n o 0 4 a 00 � IDacato noon o m 0 P M - v a w P. a a m 0 rt 0 0 ri rt r tD N ° N .j - , 0 x0 m K I ri r• 0 n r• m �' rd r a rw o � to � cn - a a rp. 4 rto re En & 0 HNJ � w 7 M7d w M w0 hl N• W0 N N rtm 0 a 8 �4 a rt ro n 0 n n o+ ID W H ro 0 n y M r 0 r+ a �' rorta n a s OD H :3 N r tD rt ra Mwr• H0 ro H rrta P• 00 w2 n o x a � 0 or ri w wa � � a n o o% m n ri 0 In m I-r w a cn P. H a' o a �D rt ri H � ro H * M a P. P. r n n rt r• rt O m w �. w N N 1"1 k H H O N w a $ 0 rt a rt x w ri ri o p z rJ I a 0 'd ID a r• 0 w rt N• to 0 a 4 ID iv y r m 0 0 `� n � a r m 4 r• 0 to w m P• r em & a mra00rtrna0o arts aWa fo rn � r a Ma rro rt o a P. rt Lq rt o • a 4aa (D • $L ron a ro OD p O Pi li.' w rt '� FAW rt W rai N w ID tr• rai IIDD a C 0 o, 0 aaa rt (D104a0a ri8k atD w I a rrtal� ID arlDOr �• tr . n n rtrww0 rta o a r trrrt 4 tD N ri o 0 8 m n a p. a 0 r w Ia. n w H io b 0n0ri row • a w a r0n L=J k r a rta0o w00 F, tr P. � ID pa 0 ID 0 a V. $ ro H r M 0 P• ID ro ID ID a raw o n atria o a ri a to a IDIDa0 N• H0 an Ma rt rc 0 r a r a rt �, r N a s• `� N EQ. s rro w ID ri a P) a w 0 rn p � a 0 r rt r0 ri w a W n n r 0 a ID II- r ID r Iaro a ror 1 (Da a s rt a ran 0 r (DaaaarinaNwrt ID � rt ro ria nww P• oa P. a rs 4 rtaaa 0rro n wa ID P. a ii' Ir• r 0 ID a ID r h4 0 a w a a ID 4 r n m 0 n o 0 r a 0 a - a ►4 4 ro rt n to ri rt r r rt ri r rt tr P. a 0 a ri r 0 kPP :0mm nri r+ a o n rt �i a ID 4 n a a r rt P. cn ro rt a ° r°i ri o ff p• PP ft o o Lq p. W N. II ri r rt P. " 8 5 ID n rt In P. a s � w y a rt ID i P. H a ' 0 k .. a a " PP 0 a Q w rt a r. cz aj v ° b ; to �ao c a, ? QA o O o a a s a, a a G a ° b ;; o ❑ L d) A a''i o o `°pJ ° y 'bc a�i y >, '� •� >, C b m CL '� ti p y id �L' y E N s, O a� q `� E^ OR U U 'Cpp id O aJ U .U+ O U .� ¢� bp11 G U E 0, A g 0 " 5OWosa •" " .q O '" vOi ~ q k s0• bD U ^O v°i '� 0 c� c°i vi a a o °' a� o 13 cz Qoo '^ v c�i 6 a"i ,� U ,ar ca y O c°i b a J 1 M C 3 ° o C7 °3 on U 3 9 }' w r, I"- N o h o a, ° U o o }.� ° .. .5 b A. w0 U N O G " C O N s ^o^n a A 03 b o w o c .5 °' ° 3 a ° o W U i g w o f z ❑pqSO � y o N AU O a) N � l- a .a °' o O .W1 3 o H a a a o cc dlu IM IL 1 g a p n u W y C° N a -9: ° ❑ a� b ° a p'+ y O sy Q ►r�' OL U U Y+ cy k 12 4. baa ° c �cb 0 0 ~ av aFg. y a' ci0 -2 ¢ o E • C . s oO ° o Eb ti b C o «� 0 'No 0. c O d; O E UO 0 0 6 ? 1 c90C 9E7 U t"b o ° 0, ' N_yO U > Y� xa G t' ai a O O � y .b a w � a' U o �, N o c o ,x 'a a� ° •� � .� � o ° a.� ,b y � p � U U° w xp b O 4° o°3 ; Z a e to w c a w a Q N c ., 0 a a o o 0 ¢ � 0 d o ° ° kn N N a� PC pa 0 vn U Z U p U Q r l a Q x A A ti b '.. o o LL • • • • . . • . • • . . . . . . . . . • • • 13 az o �i w � � �1 � � I A A C � rSi A• O C7 � A O� � y � � � !�� A� � � ^� CD D CA _� ❑ 5 d 5 d N a s o ° a ] .'r o oa oa a w o 0 py, 5 eD m CD �. CD C CD CAD o o icyy c o �.��.!�C :1' N w N .OG•. n .n+ r. m [Nii `� tj A. vi W Q0 QQ W �i. N • 0. 1! �! w G ^• C• .w•' 6' O' O' P�7 X o' K. ."s% b O � N '""' G' o �. 'n•. D ck o c Fr 7 d cl� w 7y N rD CD C rL p G O p to 17J {i p oQ fD CD EL iD N o CD G p, m CD rn E rL ryj rD CD w N N CD CD ID z CA CDD CD CD N 'S7 CD :- CD -� .w•r (D O O w a � CD . o w g d 70`, 11 d w=e, cD m O 0. rD 'rl O O CD O `Y w p CD O N O O O- C/� a [� C\ aO O n J (D CDOG w 00 0 o CDCD w R' y -D a. o o C7 (D w m 0 o• CD w C7 p C n w ° CD 5 w tf°i w 0 5 cs co m_ o CL �• r� n ❑ 5 w C7 w 0 5 o LA 0 0 ��, w C N � � c :° o - C n n. 0D' w ~ h7 n w w rL 0 CD F a < 5 0 o o x b w rD � Cxf w w cD C s t i �» o o r`D S +' CD ° n a CD c. ° C o G rL a a fD a ® 5 a F_ o 0 5 y ° r* C" C,. m n h w C] n G CD G p CEr R X' O� C N CL CD O CDp tCD om" o 5 ° CD FrB o rD n 5 0 o Irl a a pD 3 C ,yh CD CD n N G O l�D O `C o o c at o o c c co CD vUQ o ° CD a w as n rP�. o O w ° TI �7 w CD o o o rn�rn K Ct CD y G w , o - J ° h� CD CDa �' S. CD N 00 C(D CD < o c V] G. 55 G. �. W n 9o' CD CD W C" N ra. CD n 0 3 co N (CD 0 � � a' � C � � r n w l J CD 'T'R O CD CD x G O N C'OD O O i7 C3 �I o � � � � � � ° o CD a r-r 0 0 0 d `. �' _ n CD CD o CD a g CD CD CD 0 U c Y •C .-� by y C 0 N d a, CIO o o q 0 b o x o O b o ° °' ur. H C ° U ' ° 0 0 a J T U > ° C v] qCU •a tu a�Ci >, 'ar7 ca .� c°i y ° u �y O .O .b //�•y�'�� O ,k G G O 'J' id C p V a� 40. O w O >, v°�i `On v cOd O ,� O Y c"i cd cd ° °' 'u O y, O '' y O -� td z N vg 'b '.r."J y 77 �a c a c o a o .N A� al O O c> ,�,• N y s., ° o b o vtoy U N 3 q c e � °�' � "' •� as °' o •ty '� x°' � b o > a o0 0 v Q o i LL A A a o A '�- c „ v ° b a C E o ,: '� d c �2 > O ❑� •C o Q G. p, C o b O v, is a o ri a v ° y C �C W O m h N 7 �° Q" W cd k, r� "X :M O " y y I I p W U C W a I 1 v 1ca c L Z o c °' y •� o ,n ai o O I o o v .° o I d o o v c a �' 0 0 o a°i d �' G 0 0 0 ,o o c '� o �o o u o o O o °� o I N o c pa W I o '- y a� o .� U •� c°i ° . ° o kn y o o kn „� 0 s d O o o �O o �p o ' �O v .� W ,a k, oo °� v O p '«� p 'C b "a" vEi U T� � A d A Ga a� W e c� C7 •r O "0 b O C `° '" a� o Q C C O a., U p a .0 R1 W W E J F4 a� O .W-1 a, N U U A bq w k, c2 v] m E•-' v"i Q d c°i 3 c°i a� W s0. .C, F �" is oCL m � 3 0 ' > � � •c � b � Fb � � A rq � U � 6 rn M a N 3 g ,� 0 ° C ti Pj 0LO b O v � a o ° v u 'M °10 °' v b o e N s 42 co U. -0b p �� n .� °' ° y O w v O w o a O 0 wu 3 v is = " 4° - u a�i 4w, V °° Q o � g° o � 'A O 0 .0 o k> >, a� vv C id 7 W ai C u O a� v, oZ ova a V) u 3 x o u o b �o „ o {y U 0 > > b .° -0d L o �° `°' .0 0 d H a0°i 3 i a°i E o o W N U O � ate+ p N N U ❑ a+ [O L ° c°i Oa .0 N o o °j o LL u '0u In LL �° U o a °Ua' 0 ,�, o N b .� o b y a ?: �0° 0 a �C o El a 4° d a L o .� C ° o C r a N 0 0 C 0 ob cli o O ° /�� u c U m N H w° o ° H s°' 3 N [� ' !~ 0 b 3 a .5 $ N H Q a H c; 0 w° 98. o �w 'b L7 � � r-s • • � • • O O C� yo O � Y/ W y �zy iC r d d G "0- tz G1 W LA 0 0 C, O� � � C � .. o o a o• �• -, � o Y a v, c by b o ? c A O. 5' c I a 5 p Z coo kA .A o � � x G ., _ ° o a o o p CD cr Qq Cy C O 0°rQ 0 'Cy7 p P� n K r p J V�i p n rr y 'A C O p J �*, 00 �-' W N C<D n ,.mayy z CI. .7 N " �• * 'J 'C1 Q. ti �4 O W b n' �7 as ? n• n m m_ c o � �' CO w O i9 P 26.0- Iq O c o. D 5. G rn ° ~ °' aq 00 O .N. E3 m a ° a A + 3 n a �' b o a 0 w O c) c + LA ° ° Ya - n GQ o iCD '" 0 D T a• � U NW DEPTH n CD o `0 CD O Q 0 o �= `) 00 000 O �� cu £• N �. oo Q cOi O a Ur a e Eby o o a �•1 ^ 0 Q 0. E a v F-1 � kn b y u N rL .� .� F o XN � U U .5 X 00 id �•'� o y' F, C7 K �'" 3 d to e um o � No �,C o o N 3 abi .� A `cd y 00 U y U U QQQ�J d 2 C }- oho UK a, 72 CD N U N H ce❑ vi N C `+V LUd T f ,1, G. p .-. Vi 'C •• O pp y [Q rn s� � �p p aJ r a 0 u u Lam, y Uv� to 'I'd, cpi +0. li a c vim~ s. a o a v U +a' c P; o b Q v� � `^ � p•� � ti �U p � � m c O to °3 ° PQ kn y m sip _ o a ' vq; °' c U Ucd �, ,n b 10 Q + vQ �n C r � 7 C U r Q p O p I�4 � u O O V] O O A (]G b 77 l� � OM A!i O '�+ � '. + N G O O •� m O O W O y ~ G C7qj CLC • N Q lI ? W N O 00 �1 CT lI A W N 7a' n n r O &i. cz-i G. V� w CD A fb Lh 4 CD rEQ y N CI 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c l i ,41 ❑ n Cb O O O O O O O O O O O O OPr rA 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 � I f9 ,�Vm o CD ` � C o o CD O m W W N N N N N N N N LJ N .. r-+ i--� d .4 O �D 00 J CT (.A A W N y R N y N CD C A o � C o o � � d �• � N 'C7 00000000000 0 0 0 0 s u a � � r M o00000000000000 `� ZN N •3 � a � � � � a`� g a.� � M o 00 00 „ � C4 m c b Z b 00 Is a� m Ln 6. > w co� CD a d ni °1 ° ou ❑ o n b o a U po•. �+ U Li, 4 q U p N 'b r� 6u a U Q y m a �a N d N Mw o o a ® > O qU ti W rn aN .� o o �av '� a � .N •� °' � d o � U � ��• 30 ' O �; �' O O40. ai a _ o �, > C +a' .411 a 4 +- o 0 � c o s. o � o � CL d o o u N °' a p 0 abi fi a¢i GA 'C w o c ON a o y b abi a Eq > U 'oc Uo ax 2 T aoi � a z O°O .� o aoi Lf.J x 00 rr i,� z v a0. '"i w° f'�z tic a � oc No yo � a U C T o p a N e � � e op ape b by °' -It ct d °'3 � o e a .a a eb a' g� a 0 26.00" a s m O O 00LA Q a L � v f oQ Ln Cn Vf OC C O_ a� O UQ 03 '^ 27.32 " v N OZI m • . �o a � 0 N O � o O C1 C r. y DEPTH �C O LA O 7d 1+ O m N , _0 _0 E / \ z 0 \ 2 0 2 3 % / G = » § -0E w ® = a ° ©2 e ® \ Q [ m . \ / z e G / \ { \ ® a ^ g f w @ 2 . k » ) / a E 2 2 \ / 2 / [ ( ± k � k j b » /a ƒ } / 2 ) E 2 = e E \ w e = % § i ( � \ m / \ } / $ KE \ / = 5gf ± { / f § [ E« § o E % o ? 2 G E \ ) k t » \ g * \\ o 6 ® / = \ C ( f / \ \ f / -4j ( ® e ® E z \ & u & t a 6 uw f § / / ) 2 2 § 7 b ? E u e / : m / & e M & ® ° \ w = ® z u - % e 2 a § \ o / 3 \ @_ z £ a 5 3 m o ; 2 ) & o ® ® . 0) ra \ \ \ ® g { $ } o o o ) \ \ \ /ƒ \ / E \ / [ / § 9 �\ § / \ = a � e 3 / aj / \ ° ƒ a - -0 8 2 E } / [ Q 0 e [ ° / § / » 7 2 $ \/ a @ @ G ■ ) _0. R Q \ p \ \ \ 2 j - 0) E / { § / 2 E } » . g e w / : Q a - a o &2 § \ / a b ■ , a E _ & . a =2 E E _ - c ® � & U 3 / ° o = ® ± : ® � - S z '1 " § 3 % > E E � z G a G o o « \ u c _ _ \£ \ o r @ { \ § 9 & ) S g E »- - E ` ® I o E 5 5 0 e » \ \ _ ` } \ _ ! 2 a = c 1 = = u a a , \ c ® e\ m f ( g ƒ 2.- � m @ ( \ G $ r v mIL x IL @ � _ 0Q -0 [ 4 % \ » 4 e 2 = 2 e 2 / \ C m ® © % CL C ` . IL . / \ / f ID a » o . - § ® 8 ( / ( / 7 \ E ( ) g \ , \ / e \ \ § k \ \ \ \ ® \ = ƒ o o g ƒ \ \ u © Q \ % \ ° ƒ / \ \ \ } j 2 \ \ ƒ y \ ƒ / { { j \ = e [ = a e E E \ \ \ / 0 2 u \ \ 2 2 % © § \ D ( \ E \ « \ / E \ IA � '/ § � \ > 2 « 2 \ e . . j . . . / . . . vt N D A A N N D 7 O Z v r to m 0 0 0 D v cn O o, 5 n n Q u, n 1`/ ♦ I m n p� �p c o_ O m �DeD S fD 7 O ni 7 fD • fb W W 3 N O 3 r�D c c - N N 3 X 3 N. N n 0 00 N °° �° �° o 0 �. ro 3 �°, °�, S 3 u a 3 v s r a o ri D H O O rD a in •+ S ?. �+ c m O 7 O O O o o a 3 5. S 3' 3' n c c m - 7 O u a N o' c° 7 o m o w �0 3 a 3 n 3 �o a a. � 7- rz c c 7 V n m Pl R a rD 9, ^. Mn 0 rD rD A a rD c or z 3 m ra o o n n c r� WLA 0 o rD o rD O m m l0 70 obi "�' r�D �_ o rrD � rSo = fD A > > ' rD re 00 O rD m v NO O� o t0 N n`q 3 rD 3 v p v 3 a W 7 c o IA o D o o n 7 3 rD 7 V rD n m a �_ o o A 3 07 no rD o D v a N O_ d p A Vt A W N N O N O� Ul IJ N N N W Z G N O n rD 7 D nnD n n o �' o oW j - - - S X D m nn a 6 ° 01 7 rY N S 7 \ T l0 N (D fD (D fD N 7 OI N J W 3 o s ij °W' G a 5 l 7 v, rD c 0 w 3 3 D �. rl n m O0 3 o °ND rrDD 3 D o L ti m w w g o z - m a c ° n < r C 2 3 A = n o - D } W 7 o n A m N o m w o� co o 0- a o 0 X o m v D D � G In N 2 s o3 7 S o o c N c - �' 5 a n m 7 - -' A < - .�. _ 3 0 0 n I m n F p1 O0 M ri ti 3 ro x A `c v `^, K .�. w 3 In D rD rD rD r d O O 3 O _ O < — of G lO 7 n N m Q D rD fD fD N rr< N m 7 p xx n w 7 7 m d U'i N fD C N 7 S 7 7 `G N n l0 O Z Jc' a a O O n d 6 G ° x CT D o o D 6 3 a 3 c c �� 7 o f n o o G 7 �. ro o o s x o T o rD r� n ro' o rD rD o r3D 3 rD ; rD x r� o O d �. T rD n0 nnD a 40 T < ti l0 O N 7 3 O r^ N O 7 O v n O 7 O O N D O D D , v O N 7 N w d a � O 70 O rD d n rD v n 7. D Q 00 0- r 73 n o CT Jyy 1 Q � R -. R A - -. N V W 3 N D O 0 N (D N n O C M A N 3 �. p� 3 In 7 O O WO WO 0 W S O x -<n' 0 7 0 rD �` 0 3 v� 3 3 a a D m. 3 3 n 3 7 i 3 7 D D D D m = 0- Lo� 3 a n rD 7 ,O7y j a Q 3 3 O N a N O C N N G rD rD l0 x x o, ao < rD 7 0 o N N N N v� LU N W l0 rD OC 0 O K d N vrDi W W 3 rD 7 6 S In 7 $ O 0 3 3 N rD d T D rrDD rD 0 !FT O r a^ � rD A A O O 7Do rD �' O 3 O- n O O Co r7�p 3 3 d S n 3 a v O ap --i 2 rD o°o spry rD 7 N N V n CA rp rD r'� fD rD rD < O_ d O •S 0, O n 0�0 rD N _ 7 n F.3 n - p O ro = �crD vi v o rD 0 v o p ? 0 0 a a Zr o x 0 a c arD o a.9 n n � o * � D �. a s o 5. _ D R C d ' W rB B n d rD rb N Tl r ID W L,• N T M V o ° aa a Q N Vl �. C ON M V1eq a U U -�. x •d 00 U 1 qr O C N O a Con kn M r- � o COD w U U00 a ca eq a c, H U � C UU ° Ij _v � � x Ien � � x � � g 3 v �_ " o o 00 u o 00 o a 00 0p. ° It 3 o chi S o w on b a 3 Ca� .w-1 .. F. c U z .07 O C ... O °o y 3 oo cz UU U •b a� 3 K o U C 0 U aNi U U 0 U c A � . .[ ?? Aen � � b a c v V c cd N vJ M Q C r1� 'b y o .b .� !1, 0 .� v N w > A C n C ° F U C i� E F ° m CO aUi o 0 a ZU '❑ „ o � o � �� a (� `° > o N) A ° en " aQi b c°i L16o rZ a R, o C C _� 3 w iv 1 o � L CO) a o o F1 O O N �• o o y p rt n A CR to o a rt �o to 4 � O o CC°c CD rr °cam a CdC 0a2 ego ° O N n(M R. fD IA'w� p m r y r ti m w o ' p N N N .,� Cs+. P. ,r p O ww�� Q tp C l oc n n h ' 0 5 c o 0 o a 0. � ��'� C"' x C• � C � G � Q. � � � G � � � O chi RIM .�•. �� '• + r� 0 9 V tap V C" I�QQQI�y oo so n <h ' O O Q O tt3�p O N N ZO N ZO N N O N n o � O! � s G. • N C. ~ CD' � as � A < oo 7C T O O N UQy o o co qr u '� w �' n--' Oc r" ^ C a. 71 • � �a 'a � `i ID N 0 A � o c �•t. P' � o pc a z C. o a cep n coo ° n n o � In, o n ° c n5 a 531 ocos °10, o a o < E• �i m �' �• o ' DID O a aID a R a O p Q•a°, y � � C y •� •� chi x a '� C O C A U I� y bo °U N 9 A ' o C -0 °LL Fa 00 j o bo H N u b0 U oc L 00 Cap s Ate - � ' ca o u A � U u ° '}o, F a�i C d c�i � cq o u � •Y •� [' ob o w A b b u o o °o CD �n o kn o v °� a Z a u v u .. r- r- W) W o c-- 0 00 y r rn Gy u �Q 4 It 't t v et eh ,y u ° a� ed C ea y b a p u v ra �y z o 0 0 0 0 0 0 0 0 0 0 0 p y . c C ct . 2'= 1@ y O . Q ° .y v 0 0 0 CCCCC CC 0 0 P.on ° •� •C G y C u Px a k a nF°' oC70 .4C7 ° u c `° p � .� 7H ny 6n xa o � 0 0� � N 4 �' V ° W •� � by U '�' C P fy.' O •S�." N L 3 N b 00 z °� cq ca C C �°. >� ¢' a• � '.�.'.I � H F-� �i �i "3 a' W G. � W CA O - N .:'d td N td .b �+ C b➢ N M V] V] (A r�•y� M N °' bin a ° °' c 3 ? •? °ol b O o cCi •Ei ;a0 F; NId C c aj Qj oa m lu 'to, v �¢ ,, i o Q CO CO CG a ° b J 0� C � 1-i '� .b .ti � W � U d i-i O � ^' N vi �"� Cn N •�' 'a y � buw Sc5 0,# � � m � g rc �•a a � � u O [�7 7. v P7 t R. O- a• CD OC O �' G e'n tb o w �D Y h 0 ^ o. ❑ r o, ua o �, 3 +— Y y r3 m = c ao a a 0 v w p n 0 m A O 0• x k pJ 0 �:j O O O to 7 7 w O.'� o v, p• C O O =. � � ^�' ram,• °_. O' •t LA t•" 'nr ryo N N 7. r t w w ^� C �tj�' CCb � �• O -• � � y ry W ry a C H N .S. 'O CS' S 77 C to to G Fit w _7 a 7 r10 10 cn x W b W .l'. r1 4' to F' S w ry 7 C .� 7' 7 1�4N I to [/i N :� C Oo C y ro W. 0.`C r' F Z3 EA cp f D bid bd b t" r TxH H "� f c ° °. aO0 N _ 00 0ry- 0 f' N w — co a C Cto O o � to to �• n to pip w o c tyo Ts C, b w C UQ 0 to 5' o ;� n v a _ r" o r* o to C. � m ? as N rr � y R 3 CDW a s `+ cw e' r� vo 0 o b c to R ° a o 0 0 0 0 0 0 0 0 0 0 0 o �. C7 ° 7 tD <.c -- coo t"D o o P' ° r0 L.- R to 0 O O O O O O O O O C O O `Z, b QQ y ry �y c, C a; ., t/� r�' y w p w fD A A A A A A A A A A A CC b ✓�" n O N to tD .< tp rj w �p N •s n rppn�, ul O L ? O W Oa, O O 00 -4 J O CD O y N r�'i N w w a• tf A- O .7 `: n'd ., w _ W k a � > aa � C. C N ''p3�' r� Y '� CD �f y C. O .+ S r`7i, 'O O w A CCU*, Cl Iy to b '� [o'C v' CD �. .5• `ti r`Ji C/� `7 .d C� C] ti io W C� =I. p, ;� E yy C wO m ;, w�q 6i w ps y C O A N C .7 ry v, w w P�1 v`, .7 y• fD �ii in n .7 '� C 'r1 R. ,S fD tlQ .7 t p• y � - c' '. 00 o C7 a yo sky � � ao. as to r, y fwi CCD "mod G`t. .f D. p' w— 00 5' �, O oo m w w to CD o `� Ev . Q. o : °o o' w & go I� !n Cy (/� d CA Qn K � 3• �. � � to O N 0 z a m y CD y y -3 y y oo cr too , oVF 5• S. A C7 rs 0 0 . o w a. o �o �. �'. � C 0 a °° c o w a o 0 �' o o0 9' d w b Y ro v, C sr o _ 0 0 LA p ryq CD /f/l4 o ' w a m e ¢ Q . N COD _ p cp E E U W �° n w N C — co > I- U d cn Lo _ LL Q 4 N N N _ � a E co m at —E E E o [•w, = V W �� $$ a m ��f v¢ U CDM m cn m U) y z O Z� J V L > �� 0 n r ' H Q aLL C � C mNOU�. �_ T n m i N i Zc3t.s C '¢ Q ;c d C Hp@� gg L ¢atv0Z_ m3 N a) N Cl) 0 = N c N m o N c ~c G E E ¢'o o � .o c 3 0E vj � u� C �i � -U v. o 3� cr >1 a) L �O .O O O a) C O N m(j 'LO N v 0cr i a) a) U U 7 i a0 > L N O_ O) O r L a m `0 3 o E coi o Q N c _ o 0 3 m a) ` d > m o OI� � •c O� c�� ¢ ¢ `c m o a`) m n w o ca a E E _ - E c a1 E a ] Y N E m � o o w a) O _.� �) o r c fd 7 > U O a) L 7 O '� C m C O ,p N O_•- Q L w O)O i a o- c a) (` C c LT }? c0 C N U � �� 3 > rn ca rn $ a) m ._ co c01� �' o E c •° a� L y o c O LL a) a) O O L a w ^) i s N a) a d a) = O J E >, U N 2 c a) Cn 2 O ca m e of„ ¢ ¢ a c) B = o cd 'in in N m c�a c~7 N cn �' !O a �� o a o E E j co Q d a7 N(D CD as E ' ca O N N . x Lo ^O O N i Q I� > r O o ` a) -O N N O .� eh OJ O ,p o 0 N j C O L C C U E o m c cO _..I Q v) N '�V N U 'N r o L V F- O ro C U ca J p 2 j O O � N Of Q a) 'N r r o Y E C O- O 7 N O_ O_ O_- 0_ c OJ L ® d 7 � a) t U) Y N N 3 E 3 0 o Z o o c E E E Z E o ca c � ro � n E :� E my ¢ � aHoci EE Q vi E o cn o 0 ' r a z Q a) ai cu .S .U) E a) U a) > > > m$ a O O C U 07 O C N V Z II- I� �_r chi v O O O Q U E it-•' s (}U C N N c Si Id (7 a) � y L 7 O. a) C v) U L j Y x c °' E O CO to C O �' a) U O c Z d ^p H B o w_ S • v _o E v o o,� y ° �, y �S' o ro m N v 2ca O O C O cn cU p) J ''pp L 2 O 2 C E -A J U ' a) ¢ c O_ O U) .N O C .0 C Y N r C. cn C N N E O R O '00 '� m `� m E N N U O f� Y N a) C E v O - H 7 O O .J .0 coZ" 'Oi ¢•�j 8 Z - m o 8 = a) t uJ p 0 io cn U m (7 a) o o O � ,'�< � oo Z z'� � o a x o E E c) ¢ o¢ o m a 3 o N a co vi .91 o Q H `` `�� aoi ro o ,) Z o o 0. ¢ ¢ " u M vs _ E c cn > >^ _ cn 3 $ �) r r cyo a) in ro p t� n N � m U) ro ocn — �cco a) m w a) U x w o (D S c E •'J2 D 'D mnz1 O d i O d0 m _ 0 co a) > Y 2 § LL�cc �c ay w, L o o vi N ++ > r �_ E y rn rn = Q to O N °�E a L N rn a��i o f (D _130 n a�c°i cn co d N 3 c U <? ,00 E Y m m m C N E `p y to j O Y E d L1. rn co O m c t .2 Q) .c N N _ o z¢z ++ c� .°c C v_) d O O O y O N N .� c 2 = O 3 a) .+ L O L U) O C O O a) N N O EE O O O N E N 5 l0 >, o a) LL U 3 `n i > a) M is c c c 3 N N "' J a) J cn 3 -i E in E o o Z C) vIt 2 v CO2 5 (D 2 O 2 ca = > c 'p Y t t Y m E N.__ E = 5 r c co a) 5 _ N o a`> U � � o W o y C a a) n N ro L_ a) n a) U I0 O 'C r N 7 L d J J Q a E O n t o m U > t of co L c t o *vZZ) cnvtoHUcncnaa _ = E E a, o�� ❑ w aa-my. � a CD0D00to = _ y;g� www C) v'Z o �°i vv �'•- 0 CO)cn -0 (D CD 0 C.-•- =O =n.0 3 0 0 o N•0 0 c n Ol N N d G W� N O—i �`-^- m 'ro o .yi.7 / y m TO N i p CD o � o 2 7c 0 cn 3.5• w x C 3 b' o J 9 CD ema c mrn m Cr O C cD Er ma0* 0m ' mca m 1 *ACL � Drt o o lo CO rv � wnO ' m3 0 O AA(l 7 O w � C D N -i 2 m � 3'c, o n w� Oro - • 3 F <0 0 CD Z= M -00 o N D m 6xI� O a 0own 0c w �cu30rc� mW wm ww6m �CD m+ LJ 8 O cmtoQwA 3 m mx3 c cwi W C' rn Z �.w D WX D CD cL n�'m EF d a ro 000 57) D ��OcD CCDD 3 -v m mcm.� nn' N � = Cn � + w w • O D •0 0 0 0 z -0 -.,D o m goo 0 �/ � rD � D� ) 0W 0 D p <_ qnZ�m� � V" o • a • �c° m�S�'L7 � i z CD CD o w m O rn o �� m 3 2 O _ntow Cr m a ° rn� x =-.,> i� 0 + m � o 0 0 xiAa _3 z fp CD + A l0 0r w �j CDC)w c C� N o O A + B J W !D N a N rn•p to c m m Erg C Q CD _ n x T. X fD C or�.N w oI p^ fn.cD,C w�'F(p Z-n 0 zN. Cr Z l v a x � O o m �• `1 0 vwcDB'd N) --iX0m + g � 3 �w� D �� 3 � 1,in y wW� r-0mD � x cn H p1 �•ocm� 7 �crr —O > _ �, v' ca D C 0 C r- 6�a Pda Oda � �0m� a c0 �_,w_ w o c� D 0 C O ¢ 80"�" �K�m 0 c 0CD m n � 5.� �H �C�C �� a c93v_ C CT M -um {� mo d,N.. n w c=1 � w rtlp G7mO aN2°d7o _ z < c 0 D m m £ ® m37 -, }` J nm 9'ocg.m c� m r EF 'N m <o n-C o n c SN 0G)0m �O--1 -0-1Z 7_w�vaa �w 3'o m ?� m 70c�iaDm mmm rc-x0 tom w pf 3 cn (nr O�mOODTcn� m mam;Q���_Q QD SU 0 w r a C)O ��o-i mZO Z-U "? N3 cn Qo m cm mr. G)Z0K �0MMEZ c X G) =;oX m w D y v� o cnr O w � z me c� Ov D aa= 0 o r CEO z p �r-�0 Oz- z0 m"=gym"mo lo N,DD.. 3v o' m� O frin-n� -i=� rm _ � w0 w y �� �G) D 0WU)r- U) G7z o cn =r c� mm <K <�� c>O s 5. . ao �cDN' 0 o czi0oC)X 3N�2���am� cn m D G)� O 37W2� m C M cm _-- z=mga, .o y.r=Z �ZOm O�� �O Pymg �Do.TW 0mzKz_gD 9 _vmd -=" 3 C.j•OF z0ND N2� age° 3 0 �� o=� ���z >z =e�eo m z "os m `CD oaOc70 0 ;� "�-- - N OnrO �oo i do zrzaaz m C m � cn c c 1 a 3cn ��� 0 � 3 .�� � � i ��o� oZ� o mF' o a3= o a3 w �zF_,bM �C)O c m9?_ U cD 0 �m � �mmN mzD U) �CD co - crM:�� 1?< C � O o Z=cp o- 0 oozz oo z C�n � < �w �� o �G)C �D n >•=0 sm o 1 nr O z 0 co CO CD am r- o c w vc o �' �Dc zp m 2 � 0 = c < i ! o moU z 0 — x —. D 77 C r 77 p SC >m =G o n N 0 U) m 0 0 maxis w b O y H y u O q C , v Neq Wo N v W V�'l N T z v H El � �+ U U O N N O N •C ,�" N N b N o 3 o a cc Neq Q w 00 ° 00 ° ° m a s o ci, a E 5 In 4. CD �.�r V o po a p •.7 .p, Q �p 23° o id o '� v U ctj b0 �.N 0. N u U . = N C td O OE O 10 N pN ,Ly' ga. No CL L O '^. O 1 a , N 4 1 N y V] i �D CD .5; td Vi Q H O b M z o0 y pJ y q •y Q .�C o h o F- L id N N ran p OR ° o ;p00 'd Ir- O by N O ��0y C G' a� N N O m � y � ;ao aim o c o oGotu y W ed cda a c o a •2 -0 b U V] y v b TJ kn Coe U- L � � �R .�. vi N N C � •N � ;ar7 C N U N -8 rq O Y W NUS. V y ° bo '� o � •fib F, OCL +.� N � � u O �0++ � �7 •� O O O OO ^� •C y y CL N O ° td O W F O a a° v°Ov°° � � Y � ° w Cwm 'o vG, w CD no N 04 O > > � A N � Pt O a CDC 4 f O A a � � a v, w Z fD CD (a oo 5 5 w -4 n o a C, 5. a + $c� rrr-•� o ° { . C, ^+ r • a G� O �' Z w w C n 5' rn o 0 0 fD CD CD Am a. CD r, y y ° EP 5 5; CD - � CD CD O CD w 5 Peet :3 CD N iP i rr O. q• X iC �] w C 1 yyy�yyy l`� Y N r. O '� d 4 � ti I c �1 /N m r~�•. W Oo N � b O O O ° Qcr CD 00 (D pt o 1 W W J LA O p J O WLA N1 Q d W a W _� W -' W _ - J V � Q c LO J Ica p 7 N Y E w � � a) 0) -O LO ¢ Cn C Ccay Ch �v'•' U O co ,x N O x a, .� fA +�. n C — O ca . = N (� L a) W C .� `o t 3 m = .3 .= ai � d a - 0' 3 O E W � .M 0 co' cts-0L � o E � Sin ccoC) m o o 3 � o w _0 aci = ao CEO L1J r y _ N O O a) co rn-v rn wA 3 E c -j (7 :n'� = 0 m c s W u� N 0 oxi > J o a m '> Ln cn � c a CM � c E � � ccacn of � o �� x Z d = x W ow E = x //,� c v iLaa) V QO E � oO DEL ` � V c0i -a Ld � Z W 0 r- Q � ca � ytr p>E cc � c -wEL � rn m o o >' Ccn W cn 3 c � O o c � �� WJ co m � � � c) Ei O -0 .G '0r N O a) 7 0 NUr N ca U 7 E ^ Lo d O C y r + a3 D O O t N 0 (C �, O cn 0 O m 0 � �, O LO � w q o N c ate. v t Q d W N m Q� -2 r Z Q d O - r- m N 3 LO vv t Q o f 0 CXJ y o® FZ w co 03 i o® Fn °' co d a� a) o co i CO C) c Q 3 Ecui10 0) -1 ocr� c � 0 J a� 0 O n 7 = N ca0 cn O ++ y x Ln� Y rn ' = r+v v X L() Y v� W E N �.., O -0 O *0 o 0 0 c6 rn NO c � (0 � � 0y c� � co dcoW (O cOy c� 0c `o c c •0 4200 `o O -D d. OJ O N � N OJ c O O ` ' N J 'O C N,y OY C uJ ��UJ c E c ca-a O W C7 41. c as -0 c cU = Oia Ica L6 -.oc� � c ;5m C OJ x LL .0 ccnm cn � Cm � U6 -e 0,0ccg2 O � C'3 .� a> 3 o cN 0 C' c 0 0 � a? cp•-Q) m 0 y c a) p 0 0 a5 ;s c in a) m e *' xa� -0 co5E0. a c �It3 c E0 . oo 13 't —ecE0 y x0m -0a) f. xU) om f+ o 10 d n o �-� o E - c U a' ..� R a) z a' y -� o E w c 0 a� Z 3 Q. m 0J o f a> W _ , co v o cn =v- Y D �R � Z!= W v m w t C Y�� as� ca a _0 p aci _ coi m� cv C ,�. o v a) �0 z ca Ca c v'a) > > Q a O Y 10 z 0 E > > W o o m �,C'3 - a) 10 Z N c > > �R 4L = �r<m� nv c�m0Q 0. 0 0 :_ a+Qm� � 0 c�mOQ O a H C o mi c a+Qr�� mOQ v a o (on H4 • • • V Q 0 3 IA 0 0 0 • a • 0 0 a F- ",to Con III • • • • • • • /w n /1� • • • C • • • • • • f, n rn DCnc`� D " 3 m DDm"* a �ro DCnZc::E D o B U, � w w.m� m �' L)� w 'vim n2j7 m w p�F CD Bn �a rrr � �' y m7� � a w -g Q, m mF ca43n —a ry � � ^' o ° m � tsar-; tv W 2: � w CD .� g3r� Q� C01 � 26m O1 9 '- 00 �. � �, d t rr L a ZF3x mw 3 a�rd Q. x w v°i �� LO o O w o � r O � n. Q-� �r«T o � O u, b �p d �c cD '*1 (� n n m =91 en CD ry•Z m a W O f l ] A v� j • 0 � � -, a0 ` oolA m Al �. � 0 ,' �alP C d o u. o c� o m N c) m CAN r1/ a �cx� 01 nc o Of a �, xo � pf c r Ain wins � y cwi Z � a fp �' C) > � JCL m 2CD �_ Vr O C,7 m y o N G H co o c7 m )o LL co m'ti m � emu, °' oWo • in_ m m Z Z .A O 7 C m � 3• n� Cr o —9 cn au o • . Gib ��, CD �) x 0) � � �� nK Nm m " L m � nT - ti o m � m �U) LIP gv � � w x U) 2 a, c- X CD 3 � n o cu �� n +�u, �u �a Nc - v) 0 m ' O na ID C2 9 .�.• G. C o CL N "�' R1 O -a CD o cr c m CD m m c a tD w 0CD Cn w v a 3 57 G CD o m � m Uj Y En C o d v 9ldqiw_;UN ups- "1, S < III m .lam�. 3�x: N 'A dam" � a 3'o ww - 6 N rn El 0 CD m cn a C; � •� c, d c: ° a� w � o p >~ is a� 00 ca 00 ° un � o �° ? " a pq o F" 3 id 3 i a°i y a, ^m w ^ ° a v w ° C o o y ' o ci Ca 0 W 9 W �° •� eb o o n c ti w N c 00 c a 8 ra o b cn c CD eoa �o a`i c"i w Cis u U. ' ° °pO, eu q •� a� 00 Ut� .rJ N N N pp cn 0 N 0 ^ id q N C•+'. N p O F. ° p p C + U Ij cn V i to N Ln cn u Do '•_' vNi cUd m N p kn^� F�.' 2 U v� f 'v, A �-, CA Ln 2 F+ CA %n p k, o w A 3 p > > v� T o f� . . . . . . . . . . OR a.•B o-- � o� u N 0 o N b ; on co Z ;�, � b •� N � � � �" w N IL p 4: A viZ5d O O O N G y y o CG nC40 kno v' o N ad C .12 dE N M G• A � Ql O ° O N p U N N , •u � � W W a° a ro 0, � e rl 5 ^' w o to r) ,o�, g pa�dt' a w a Y - . . . Z y/- .] O '"' N N .�' 'b p, P m 0. N w O A O N N N A rOi, `? w w va Y f�li, v� v4 m con C] C] +� A n "O�' 5' . �. rD �. .r-r o o o 5. o a ° d ° 6' °o o CCD a ci f D- C CD rD P. CD c� arn G N ov ao R CDID I ° p o ro ro '+ w ° cw ro b O O ,a y0 1.0 w R p y ro 'i�Q"q ;P Cd ` 7i 9 W G W y W ^ O 008- Jr O p O 0 0 0 0 p W C4 CDro z .I y Z .Izy Z III Z C g' p o•° O Irl Irl O z z I" � Z z 0 0 y $ O O � � � °z °z °z °z `" z � � -asax .► i 0. kA O O LA a 9 b £ Z l rA NO U U U U U U y LA CD Pr y � a '» � •� Cn Ot'' o cl O Pr <ypa ? aa°o 00.0 CD C rt o' F'n rpi w C 5' rw Q cvp w e c cao ro id y �jg �lJ '� � �. C �3*, O' ram•,' .�*' �' �' 0. .+,� O. � T '�' 7" f¢/1 � CL�i 00 ID c rc H N w w Q V r y CD CD e 5, p - ° .as Fo a CD 5.°Qo r ls1 yW. a ._°. ny n 0 Oc rho I < C/1 CD CD + Er A a `° CD ro a � W � a O u O •b o0 CD T V .� � O O � v°i '•� N Ob 'O °O ai U oo -t �, � EE ° o > rq r4 Ra w to a rn o v cn L E ~° Co e ,; ,� .. � o ,; b •° � b a •� E E E E E E � � 3 '� � E >, E CD ,�M O O y y Oo Vl Vn 00 W) In � 4 y E n n N n n ^O G C td O conN N N N kn c07 QJ o r, M o c c b a c c 4. U a� ,'• o ' E °' °' b w E o n � S o y ° ° " o � OHO it ed od vi e d vi vi ? a �'N N a d d �dp pdp pdp d d co 3 . U U Ln W Cam+ v y r� E F > 0 iF N k k M M M N G d 3 c� w� a� cn o �o N �o rn W o, 1 o a� o z 7° N N eC ° � v W, for I II _ W W .a 4 z n n n �o o E N .5 O O �. N N Q y y mCD 964 L L z lu N o.y c a�i ' w a oo, c a a a, d E U z x 0 0 0 0 c E go0 I=- ° Z er U z 00 m N oo n o �' d E Y40 `° a .o `�" •o E c ° E o ° c�a al N •� a� a. c� � Y ao � a q a Q g E E E E M }°, d o o o U a b $ y G� ry OO 7 N N U p a0i O b b0 O LL ¢ �"� •b p A .� p .� Pl N .b galC ,'' Aof. VJ ® A O E 7 �O �+ ry O 3 3 rn 'a7 t7 .7 m w •� N .� ro • • 'z A 0 N Cam' O" O (or Oy eon °o w 41. R e fD •� `N° ^ o t�1A � °rJrs �. yt17 i 6 R C �_ w � ". ar, y o ° o w � a L .��. 0 ° CD w Y v O (D acQ m "a a w Q m H w c n N fD ry f° Cr1 [o to O ° �o Ow C p' (D AE. O Q Cr1 Z t�o � N w °t° �' H •moo ro r C p tNo 'b �' ° Cb yy » •_ w O n � 1777 `3rC -C°s � + ° ro a- �°y � v A N. y Cn CD 781 p g o a`g CD CD Y x �, a'r- a a mac= n �3C' ,yc 0; co .11D ^ oa o o pw rr # CD y n ° �'Oho o' N oil Q G O 050' a c o ° ,r a 7, O C x d w o o S , beD w o o iy G 4C) co b ° a. w FsCD G o to rA, mo o ❑ a �• C � w 00 El CD .ram' Y -R df V) 0. "y p N. N W pn.. 'd a•y�yy w A 'U ryA w C�7 D\ O w es r� r� E• CD ° CD C o ao + ny � .' N 3. C � H �n w CD -s a T F FD T + T M a °0 CD w co y b o v7"i 06 c CSC e - n0Ln ?: ° � •_ ° c 4. H yZy A eT' Th T `° `° C7 w a ►i Q p tr rn C Jr ua C� rs °LA C Q d CD k 91 o x7 0' N ID ° p ° any `° Q r o CD 0 n C CD " C N n CD '°'h �p CD No �, O c°i w CD CD CD p c�D cD a CD y N w C� c ° oa 0 as �, y � b r[ bd 3d � a o I"D � � o Qyr. oo COLD co w ° o c N G CD CD w C R. C '' �+ C ° L��. .w. N CD O C,C ° fDN y C H o b o w y o o r x CD 8 CD Oq iO.1 w eD F r' Z £ ti S 9 L 8 6 WO v=1 a3i3WfIN 133HS SIItl130 atiNnn3sr.IMOLIsaal3uaoaMons waVItl3ald N0110HOS30133HS r 1 LL O a �J a 3 e v ` trt•'J,s PeA1932b NL I I 1 1*1 . •IS••+1.'(%W11--d LOWa NL "U"410 v 3oLN3 • I 1 1#101 Aq P811e1su!/popinoJd oq of Ouu!M 8 1!npuoo Bul4ull Su!Pllnq IIV(ZL t 3an,'19 - :J3tRJ3Y 73N73 ' • ♦ ♦ uml Wnnq • n3)^o xt3aA J ♦ ♦ " +ijui0p J Ll Bu!ppnq ul pa4e301 s!dOVA 041'd3Vd a4101031V31030 aq 01 N D • ♦ • awLlte '1"""f w•m•nf f f pel!nbel so seu!I asalil JO J.'sau!!auo4dolal SlOd x Z soi!nbar welsAS s331n3o1Jo:Jv3laLOL) sa3inm3,s.:s3aocrv,s' • ♦ •witt+•waeovLw•Lv++lt f ;a N ► • • -WAWWt *•i 4Af t void lad se 13V0 OOOt•0l1 Japod a Aq pap!AoJd aq of so walsAs w1e!e uagwnN g3!Aa0 uu01V a)!d (-�W� T♦•♦♦ ♦ ♦ InWwl•M c aly 0y1 Jol suo!lets iequa3 a41 0l uo4e3!unwwo3 l0 sueaw atll(Lt Z J C V i •• ♦ ♦ 10 w,•Iw•VM•9 1 v r D / •• • • ♦ L 's Je ues sluewaJ!nbw lP OdI'ZLVdjN'O3N 411M P p 3 8 rHVI¢3o ue b _.i-!O O r ) H o J 30 3 GIVI 41m)N1W3lfAt eauepJ000e ui peiewwiellpernaostpo!lelsu!eq of st!nw!3!w¢!V w!d(Ot zacziM 41htf � tl SL18S H1dd I'MW 8 J y g: ttt ttt yled 43eoJdde ap!4aA AouoOJowa a41 woJl oIq!s!A Auoalo eq of put M m 1AND NOLLtlOULLON-OWN a1Vd O31SIM1 ald�I.19LN tl ram] i f g p '(145104 aigeao!Atas a is)Su!p!!nq alp yo%SZ loddn 041 u!paleoo!aq D m Z MID 3NI7ltlN0l"IS aldd Y/8L� fl n --v----- D � �d� � €3 sY of seia!4aA Aouo8jew3 Bwyaeoldde lo}pallnbai sagolls loopin0 (6 aweN adi� uoljelAaulgV it f a -{ M f ��" (S'41,'L1,ZL VddN 8 60£ t"LttV OOI)jo!oo u!pai aq lie4s seo!As0 !ana! pue6e-1 Mnailo UAL 3Nn iinmo C z Ou +A�•8 o vafp 8 I r loog anoge s04ow at,Pus Zp ueaMtoq pea¢!d aq Be4s suO4els!Ind (8 3WVN 133r0ad C z 0 31$j!� �r« (Y!8(£)Z'£'D'S'Bl U0113aS 9L/OLIOL :31V0 r n > r. a f 'ZLVddN)poz!uol4ouAs aq Iie4s sag011s asoyl 10 4seU a41'MOIA JO Pia!l W D k,; 41 u1411M goods luau¢{p¢JO wow awes 041 u!Big A041 J0410yM aul!1 cn e z _ %/�Y awes a41 le a!q!s!A al¢sooue!!dde uoµvaUllou ON4 ueyl SHOW ua4M (L Z D m • Q �.w�N._r>_w�.wrwnpLpap '(glt'f'V'S'8t Z�(0 ",I. _,l rvnuoo-�Laiet e i wrlML I q I Nbrl d J N I SdH d / �l I S `0 c'�- s"IdInoKMAS ainol Z ujiloo 41!M aouep J,o1q u! LVd put pace d a !e4s sagwls Q D palunow Bu4!aO'(ell'£'4'S'9L algal ZLVddN141!M 03uep1o33e u!pe:!s • W m D. k aq Be4s sOgO'Jls PelunOUJ II¢M'(Z 8 Vor'S'9L ZLVddN)'level JO3!1 anoge m � „< X wnw!xew„g6 of wnwluiw„09 pooe!d aq pe4s sagwls palunow IteM (9 0 0 M -� gale c •JOIe �r ) Dalenp3e s1 (uoilels•Ond'Joloalap a>fows'MoilJalaM)OulPllnq 3ppads n ell- 1 Bals O=� 0 m te41 wwl g3!Agp wivie aly a ua4M pOloA!100 A!uo 11!M Bu!pllnq 841 8 4000 ul seo!AOP uo!le3p!1Ou luedno3o a41'3lS e!A walsAs Jol3luuds Q z ai4 sOu!p!!nq 43ea 3ol!uow 11IM dOVd 041'Owpling Al!unwwoO SOltlO121351M 0'Z tld �- ------ OM ul dOW u!ew ay1 of paloeuuoo Jole!3unuuV wJ¢IV aJ!d elOwea 9 11 u A e pue A!ddnS Jamod atow0a a-ell Him Ou!Pling ie!luap!sw 4003 Wi1VlV 3111d 0'L V S"90'18 ` ffi 'BulPi!ng Atiunww03 341 Ul 13810301 d3Vd auo OA¢4 IINA Aliedwd silll IS 0019 9 0018. SlIV130 tld 0'0 Vd - 1 91. 018 - '(Z'9'9'OL uOp3aS'ZLVddN)11104001 JOMvOJq 03a a 4tim Ouuadwel 1SII 133HS n B 9018' < 3su!e6e pwnaeS put paleq¢-1 aq Iletis wetsAs uue!e OJ4 041 SOAJes ieyl � - ----- i JelieaJq 7!noJ10 031V31030 04L '(L'S'S'OL uO!loaS'ZLVddN)walsAs 041 _L- 01 9018 r I of JaN 0d I 031V31030 Su!A!ddns s!10411aued jeouloa!a g41 to uoileoo! ( ! a3uod d,3oo 3Mnsn,xr3 Jn3MdM3HLra.Y 3NOH:sI:ao J000lnO 041 of lauuosJed laaJlp Iie4s dOVd 841 u!paoeld oogou V-1!naJ!o dweog 6 0018•_ (• Ql'tMlB I NOIldllfOS301 31V0 t.1�1 3VAOZt 1Vm 031030 a 3ap103a seliddnS J—Od gl0we m -- i I � JJr.:N L'••aPlV o.m,.ws Z.XCM I a3um1 HMKt 1,rM 04"3.n zw t ae3MlstaWH or t•itll a II¢8 d3tld(V ABl•xauloD L 060338NOISIA 'SJols!sw'103 Oulu!eluo3 S1.101 3o!a3!Aap Ile lage-!'(L'Z'VL'OL / 3a t'•OMS I h I I i-__��__J � I a3113.1 SNDI Yl9d 8301Ndx3 aaMaa 310i13b tlwr011t/30n 1311A .-FUN `•' ZLVddN)uo!Lo!psun(Ou!Ae4 AlU041ne a41 put Bupsll saJnloulnu0w s m T ot'��18 JJv.tt r xar aw•mar rxow cz MJ1.0 x31H30 /VA A^t13n03WMOl NWWf J/ a41 Jod poisel put polleisu!aq 11e4s s831AOp put swolsAs 11V (C omm ll'JOlB ,) en.cN :••a�•ns•vlws-xxosv LL aauod AWIVIM HMNN3Hxaw [� -(C-Z'9t'OL ZLVdjN)uope301POAOJdde 01MWO N m o 4 Zt t1018 a awmJ a•cd LI OLAov er+auvooraeaJ Sus ® us 1¢pap!Awd aq OOya suope3!l!3ads luawd!nba put(,JI!nq•se„) r g <o se of paJJalaJ es!MJey10 s8u!MeJp pJo3aJ yl!M Ouole'weisAs A a•y r o ps r`oaPNP.p�ns-xoeu I a0Y11.3SUI eme 3WMIG OIUN 31gwe (may 041;0 aoueuatu!ew Pus Ou!Lsel'Su!leJgdo ay1 Jol suo!lowlsul (Z x 0>M m hywry £t l7U18 Ra3HlaM Sa31J10 AN MD1JM3lVM tI x z W m (ITI Z'9VOL ZLVddN)uo!toodsu!/o awq o4i le Joloodsu!rHV 041 5 �N�41)n8 sa�Jo.e sa3HWAe aadnnaavwlas a 01 PaP!Ao/d Oq 1104S uoga!dwo3lo pjooaa pato!dwoo 041 "Z g_ ANOM JO d3ad N-t+ ten.-�awrn,3 r 909N Z1VdjN)uoNaidwo3lo pJ030a ZLVddN ue,ala!dwo3 1104s Jellelsu! welsAS wJ¢IV-!d ay1 sued penoidde 041 Pus SOPOO BIIIuJ•AOB O o ...aw3>.eolnr;"-xos0 alum) rim 3MOM13•MMIndrt,rn3 lie yp•M aOuepJO33e u!aq 01 pawJ!1u00 PUB Pglen!ena'Pelsal'palleisu! aauod af•VO wm3N1aNN 4LcI'J3atl3, DEMO ueaq se4 w01sAs 0411¢41 Ougels rHV ieooi ayl of uo!tetuewnoop L4 L'e-9 LH "B'N 133a1S HIPOZ cIH3wJarm3ae»o)/nar seuahaldnoaaxoex3ra uo aJw e3smt1brd No[l a3930 looms SP!Awd 11949 Je!!eisu!a41'uogoadsu!Jot Ou!Oe3 01 JOud (t Mow ama pua681lo4wASuuelVaJld aaoweaa Jo Aa3 SMON NOI.LVIIV1SNI Aft EL4IM dM `NOIDNl�2��d ' aDO,I at4iu f 1 OU LCM tr•sr ± Io AdOO I 301JAO 1 uJl CLl SONaOo � .. I I ,I� n.• 'I]gYVM IMSIM IINJI Y'n�f ��B ,(� .. ", 'r �Jwlne NwbY T �t 3yy pe LYI 3N1N WNVIV 3N1 =1 r �S71laW7d III 13A31 -l- ----••-•^-- �, rC7-07�6,50,Z IL�-� LCM E) N I C1 I i n a �^ILuens -- •- T. I-s Mow 0inva Ina) ' L am )� Ww/c,", lft wf1 (MOOS }`ir 'a•Ie 009VM ))SZ6 db�W �lll I N I In ��� " ro�eo vm'uoAM3 noel uo,o J a/r ':W N011331ONd 3NH S i\PiI,�nif NOT T VYIV i(!\!i•T�1T A Ali L71LLYY'111�1Q11t 111 LL♦ 1 A♦.LJ1Y1.1J1J W�l 6 Z I £ I ti I 9 9 1 L 9 6 4 Z £ Y S 9 1 8 6 0'� V=l a39wnN 133HS wavly 3MIA NOI1dINOS3O 133HS D N '�= 800-1-A ONZ � o T. N ;r 8001A IS l r C v Z -lC v 2 D I O z I - Z C Dm Z Z F m --�,- N - obet.t i 11 �.-,. W3i NiBrsixANI$A rm.v.' ,�,� 3WVN1o3rOad -1 3H1V1.F.O1B_3114l ► i �ms+ae 6-_I I I''j I eelw N � I i I I I I I I r M lE 1 roNlx ------- ------� ye MOO I I W11(d I 94/OLI04 �31VU I "'d++� 1 ealN3 r I _ 'L Nntx I vile I —•�------- 1 I - 1 � I 1 1 I I _L-__-----------1 I I I I I 1 _ 1 r----� 1 _ v I I. ------------� Ir 1 f3 3411 01"ors nxOlsi etvrsa N I I // raloNn wm. LF---J 81diY191.I Lf'-----1 "Um saivO WOOH 83SI2l al3sla 0z vi "AM wamr3al�0Lm _ 43EMt N3 S,IV13a VA 0'0 Vj -J -...n •'- 1SI'l 133HS _I _ ?o Yy x Li_#?p11f1U118+In3LT] ,}I FIB 31V0 -Oa003a NOISIA3a -�v Oxpo A�TmAm H1fKF11 OamW�o a � �^'mozS V J V ACOi�a�oo N a0017 Q�£ n y0o� y vyAz J # m z;,m w e0 nravl, � rrarr Mow auva allowo3adonllo '� �� • '^ r I N---- I w I ASIM ANlll� 1 I iWli I � lifYl: 1 Idl 1 r I I I edit, I woI 1---"------- r o I a1 x r 1 I VI 1. netas WINcdt.oxono _M.M. r,txaaM- Q t., �luolc muLan U`, -- *Pa am wm Mo wln 0 r06OZ4 MOW OI�VO 0096b61•9lk 60Z96 VM•Ae/aA3 peoa uo ql0 OEL! 'ONI N0110310ad Maki /�/ f I Z £ h S g L 8 6 9 L 8 6 0'Z VA 839mN 133HS N3SIa/SolV6 wNVIV 3ald NOILdIN0S30 133HS I] N D D o X AN v Z C V v i -J p -p u+ae [I JO1S o3mm3walmoato O= Z NI eWY0t 3MOxl a alWAM Yt D Z D O A , dovd V m , st D m Z -f GyrS1 -- � �I •d /• � � I (p n u n u n n ;l 101A sd 3WtlN 133fOad r 94/OL/04 :31tlO n 8 SOIVOIN3SIN 02 Vd 13 WNVIV 3NId 0.4 Vd SIIV130 Vd 0.0 V3 .LSIl 133HS NOU&HOS30131V0 08003a NOISIA38 m n c,gg n9ar0:QW�araA�MPtJiWlWrOgr IROII a$_"�5�5 rwootarl It�71gP1 IK9BL/ Ala trl>1 luo L,u►ipd��aAWle' AWWO o.�q 4wA�t (•Art rl�»>'>doorlr.IFuil -- �,•f�l NM AaN31w3xi Mo,wA7LlA,fltt9 E,0 UIli00a1000aI� P6�Q - IYA7LJr+9LW3m Mo1r000H A�l7MD l0 y m room psi u_aZl`— ivn►�r+arw3w wo,lubw! kow - o z y o a w0000tt x NM�RlO i NMl uL. �_ � t�an a uWZ et Iqn e/awawr M.fm ut 1" {o zN o 0 o uat m' t i w voli►ae 6 Niii A7ii3no3uAMInrlNoil"_ ow Gaon a, oo HM AOHano3luMo,laloN,_ __ ow w ww LaG7rw N oin M Ito _ — T e m m 3 q 1 ._.......-. / + NM gUON aA'1 MlYIO "I l0 1 -— �ctsa Aonano�ue - F _ V.q _ H_M�yD1_ wu wwr A Wk4ia� h , �-� --- - �_.._ ------ -^ Uu . si Oo-ai� 'ryNaO�Wu,Hu 'tODA[ _ Lan wubLiirmv fir to ) 1N�000r ____. - ___—.�� � -�_.._._ ._......_- OMMNN04 U V00 m $n `" (nWb{O� it[at No�orr ,t► �NM A9f131W3iW 1tl011 Rt 00 la NM MY ANtiVlM"D WLt _ �t -A�� 2C •'�^�"'-i�M Ntl011 Rr Owfp z rIIHLI a K /IM laWll Rllw Rl• ,-._..._..�.. rALlta0) E1 Yg000Yr v ti p s 100001 M� r ♦ raA A9N31t0]W!Ma',raloN M!'NO IA1MtOt m uaox.vgaoada x NMxollano3a�Nwirwal a too tawaoa.ee az wanano3alMa,N1,o� x� � tONOiMlnnaoil wa tro Ioa,Tiippprr ott NMA nwaaiamragNAyY19 no I Ro r LwAaN3r loolNWHnuw�o - a , fA w m m ---- vAmt OLN4100ar1 C.p aamI ISOM'aall 3N" tlrm,31iUWOMtlON Z+ coal YoW00[L a NM'l1aaL1oA11 L[r {AI[010, rw /x[t of VAWQr- Io'el II/A A:IPA[t03Nl MO,Nigh IM111t1 L00 01na0 W al r el tIM L'llt3[1paW Alai rllA,N Ma1ND ,nCree`oSO IlaGeIt a LlM NtlW/MrrlrASRr Ug41 rNad wit ao Oi wa000a {I Lan Ilyp11N11.M►LxrlNliw_ Lnta` iat wal 46 ea HM'A�`lnolloA wrninro I6o nuaA 0001 N9d tlaQaSaaoA aelnwA aa„nj'aaual[to _.x a 0-a mvi".-ON Md-w11w0 dap aft. ovxq;"lun,nO�laoaeta'a oaaa�rlddV ON wd�a,MaO 'eotp o601loA�a6v110A-tw,at0-tuuga I""a i•nlsd v[L oao"ell`taw'"7�inrNm.wl a.�oi a.vr+ 'wadvswr�rb'ra0 - L —- Ip- -btwQ oaumWdd oN Lad aotAap T,al�b�LY�Ogp OuAq+Yr'p1/1 l.1al;arnrtNwiN MgViuYiWW�t1�a Lrl H 9LH VIar1ROr,aN�lunaue t�llA,agrOn#9 VlagYl A1r16"�WIIYINslq rt,rgr�pp,1 KOl dapo wpA 0 NYr l.Lat'.eAgNaMW waautY anaq yr 01a71,d1 a3GaMl�r:01 rFtq 1118MVdU3lglMt�1at AM „f000[sOrNatW 'aAVOC it wrap VWWC'-N'-%W MArOt'rOgq,wtAWtrl 10waloN'"c v*2 ONMidlOataML�r,9t wo cm ..WIVO vW00t+0.waW *aM'0['+07MWgft Wvopor1."U p.0 S61S llnaNJ 00OO 3d.hued auogglna errlll� — --- —"""'° -— - loll -- Z61S�lInWlo oo;Pl®o Sd:"d SUORBlnWO ulbl!o L6ISM"'I0I0 00 PWD Sd IOUBd fUQlI9lnO[V31lnoilo EL4l, Sd,� �� t �� ti"ggRY t{ •�tr1�lL�rwOr10 t a Was �7,ra.4A ANMY WNto WAS JYIA IYNIY �a3lon" 4,9t NL1►t<uwAipiNts a , w _--_Laa ggMNRt ast '�+'ratio.tsnwl - - t'L[:Og000 - --- -- VdAN wit MPOOratnlal woo _AWWO aet t itav�iri�p3u ori�avnt 3eoviaiaia,I uMitaN U 9 r ;wxmo ftwa�+lOrrA wA A�N311a3Nl Ma,N7g11�CL Ml1LIa +x rwomou _a_ °'it°»o mgl�taa3'wn inloNwo tL +wuriwl _ _ _0 v,a�0000 "I�ii.W�M NOLLDy7jpNaN011YG61,l,d 1 l9fd 1 a Iwp00a0 100 wW100 16unauC•31aNP Oland 3g01Wt .._- awwp pNgaros 4 ,it[ L'�dlpl [t F9lStlrglHNt IIII il3l ----Sid_ _._-_._ MTN0091 °1?�ODSc _ - _ �!N3df!d%9 LJML)OdI/Y01 t 000i 3 +d - 7060Z1 amld lawl uuery L9M+olS lowli /gougg ugpteasap _" •.tl ON Uad VIONW ` dM01 alt'131 a eawe+a -I %Eo)walin Sd:pued lot sud,Blnoleo/laws MOW OIAVO 0096.06Z-SZh 00,796 HM :;O,en3 peon"WE)rr{,: JNl Noll D3108d 3NId � � � Z fi V S 9 IL 6 z I £ v s I s I s s H3evjnN 133HS NV'ld xJNDiNII EJNlallfl8 ails NVId ONI >iNil SCI El 31lS wavly 3ald N N0I1diNOS30133HS 3. x t 3nia x L H1N x iran,e r t NOVlB x 1 03a x L Via x L 03a x t 9t0NHHlx 9L%P►FIH x I H11M 1MON0 Him In N > `d o=n 1 r --- - ;I'm m31 1 L Z 9Q1B �' Ltl�Qzzm LI 3aJx La 3ma x e L Q3WtlN103r021d �3Rxi N33aflx 1M 11nON00nimi L -31Va x t O L I 311HM x L 3mBI y 311HM x L 3ma x L lone x L Q3a x L%L F- - N 1 HOVIa x i Q3a x L 8LM NH a 9LN NH x M UI1QN0 [n ( _- HUM Ij16 Q Lil - -- -- ---.. ------ _ �11 �-_`. -L �a�8 9 �a�8 �� f 8 ( I_ii,&* xL'N33a0x _ - 1 311HM x t 3n18% ` ,^ 1 - 1 NOV,H x l'031M a i �� J �'] I 919 inatx H111nON0 r-- I l ---� A10113A_x l N33HO x t ^ _ 11IHA1 t'3n,0 x t I '�N I 1SII133HS I Va�B Nw'113*/'133axt /� �311HMx 3nlBxt J St-JI 91 M NHNl X k9tllB x 'O3a x i 1 r M0113A x L N33arJ 1- I 311HMxL'3nl8xt ! H1iG111f10N0 I NOV,B r L'U3a r L'C -1 r H11N1UnON0 f p I f NOILdIaOS301 3*13 i I 91p NHHL x 9 0a003H NOISIA3a RUM 1,ln4N0 N•�-�-- , ! q i _ ' __ N 0 � SO]8 g mq A I -��/ _ _WO xt N33" •'��n��a (/• I _ - - r --- -_N f �� 311HMxl`3mex1 'm r — GJ 03a x L [t 9NIOlinB i0 Wa 0313 NI 031VOOl 38 Ol a311n'J'D313 ❑ 1'• �/ �- -9LN NHH 1 x ------- +--- UnQNo r XOn N011ONnr 031va a0001n0 a01a31X3 f �"'mpzo �, 0o� L _ 1t nn x nyp �- 1 `fin 5 •�.lQ�B, MO113Axt aox II y hzgn 1 r MOT73Ax_ L'NNpx�h� I xL 3m xt 7 I,I m so ( - -11 �I 31JHMxL 3 laxt�. k %noX& xL ` � /n� MOK18 �' j I 9/M NHH1 x " AJ u I I n 9LM NHHl%• ! H11AM1 Il,nONO SNI p�. 8 H M11nQNQ lljfll) . ( >. '(SIIV13a waves3811 ONlallne 3 1 Mon x=F N33a�k t ', U Cl U1 U10� a03 SJNIMVHG WHV1V 3H1d 33S)Ll. ONlallne ♦� 1 -�I � I f3UHMx t'7n,e x 1' O'iZ3A x L N33a�x 1 : ... V� I - ,l1 �k I ,O 4z t'038x L 3LHMxL 3f11H x 1 �• NI d0tld NIVW 3Hl lt/a3HInb3H SI llnOHlO dWb'OZ m 4 , 1 gj N Yy kOV1ax L 038 x I' n :)VAOZI,a3lt/Ola3a X L '.k-lddnS H3MOd 310W3H oN wa3uio°i�D � It "" � Hl SINNHHI x 3 L �. 0010 18 i � HOV3 HOd im?JIO dWVOZ OVAOZI,a31VOla3a T H11MUriQNoD , '�:' ~ iy x 6 38InO38 SWOON 83SI8 831NNI8dS 38Id llV(v '(LI•ONlallne NI :.w:. M0113Jl x Z'N33a'J z y' _ r i (131VO01 SI d3V3 ails 3H1)LL ONlalln8 NI WOOH 311HM x 9 V03U x 1 -- -'��. ,_ L 1 � ` `� �VOINVHO3Wl�b'OIHl03�3 3H1 NI a311nJ V Ol H�pie x L'03a x z (' MOl�3Ax t N3 aox w r_ — NnH 38 Ol JNIHIM/S11naNOO�JNINNI�JNIO�Ine(£ ^ ^ Mom x L N33ao x t 9tp NHHl X LL 'L 311HM x L n3a x` _ M X L 3 1 I 1 HlIM lInONOj i Dk Vl8 XL x Y 1.1 CJ.� 311HM x L 3R'IB x L kOV'IB x t 03a x L 90 NHHI x r� 9t N 1 x. H11M_ llf1l7N0 HUMUnoNo ONlallne ldnalAlONI NO 03SVe 38V NMOHS eel.ox000 ; ,~`CIJ Q \ SN011VOOl XOe N01IONnf'NMOHS SV SHIM EJMV Cldd.AN , I _ � �"%' 94 d0 WnWINIW V HlIM WOOH 83SIH H3lNNI8dS ESHOV3 -AO IIVM H01831X3 31-11 NO HO ONIaIIne - - -raj M - HOV3 3O WOOH HASIN H3INNIHdS 381-A 3Hl NI 1 - -----1''- a31VOOl 39 Ol 3HV NMOHS S3XO9 NOIlONnr(Z O 'JNISVHd inrOHd aNV dOOI V SSVIO V MO-1-11A s t'N33a0x► 803 NMOHS SV 3NOa 3e ism 9NINNII`JNlalln9 31,HM x L arils* 'NVIOIH13313 3H1 A9 o3NIWH313a 39 Ol 31no8 xovlext 03a2.i U MOLY 01Atl0 1 -_ " - ��, T•h / v a (%tuuNima o lOVX3 '3ON3H333H HOd 38V S31noH 11naNOO(1, 0096-06Z-9Z6 l 00L96 bM'Ae-18A3 ��� S310N N011d11`d1SNl I _ -3Nl NOU03108d 38ld I Z ti I 5 9 L I 8 6 Date: 04/03/2026 Permit#: 1191 Perm Date: 10/24/2016 Review Date: 10/24/2016 Perm Type: FIRE ALARM Review Type: FIRE ALARM Target Date: 11/07/2016 Scheduled Time 00:00 Com pleted Date: 11/08/2016 Description: Ok to issue Review Status: Assigned To: z.Christopher Young Tim eln: 00:00 Time O it: 00:00 H curs: 0.0 Property Information PDrcel#: 00829100000103 W ARLINGTON INVESTMENT LLC WDARLINGTON INVESTMENT LLC 1 020 WEST CASINO RD 20227 77th Avenue NE E VERETT,WA98204 Zoning: 910 Undeveloped (Vacant) LandLot: Block: jari@william anvest.com Permit#: 1191 Permit Date: 10/24/16 Permit Type: FIRE ALARM Project Nam e Park 77 Applicant Nam a Fire Protection, Inc. Applicant Address: 1730 Gibson Road Applicant, City, State, Zip: Everett,WA98204 Contact: David Mow Phone: 425-290-9600 Em al: david@fpiseattle.com Scope of Work: Apartm olts Valuation: 3500.00 Square Feet: 0 Num ber of Stories: 0 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 11/16/2016 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Launa Black Property Parcel# Address L egal Description O wner Nam e Caner Phone Zoning 00829100000103 2 0227 77thAvenue NE WDARLINGTON 910 Undeveloped INVESTMINT LLC (Vacant)Land Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# FIRE PROTECTION David Mow 4 25-290-9600 1 730 Gibson Rd CONSTRUCTION UBI 601 848 346 INC CONTRACTOR FIRE PROTECTION David Mow 4 25-290-9600 1 730 Gibson Rd CONSTRUCTION Labor and FIREPI*021ML INC CONTRACTOR Industries Plan Reviews Date R eview Type D escription A ssigned To R eview Status 10/24/2016 F IRE ALARM 0 k to issue z.Christopher Young Attached Letters Date L etter D escription 11/10/2016 Building Perm i Notes Date Note C reated By: 09/01/2017 Bldg.#15 Kristin Foster 11/08/2016 See Master Fire Alarm Perm 1#1194(Phase 1)for fees. C hris Young Uploaded Files Date File Nam e 11/16/2016 1953063-1191 Issued Perm i.pdf 10/24/2016 1909768415 Fire Alarm Perm i Application 7rfezz5TduYDy_.pdf 10/24/2016 1909769-#15 Fire Specs Part l.pdf 10/24/2016 1909770415 Fire Specs Part2.pdf