HomeMy WebLinkAbout20227 77th Avenue NE_BLD1189_2026 (3) FIRE PROTECTION, INC. PO BOX 12642 MILL CREEK,WA 98082 14251 290-9600 OR 1-800-681-1125 FAX (4251353-4546 October 20,2016 City of ARLINGTON - PLAN REVIEW RE; FIRE ALARM SYSTEM Please find enclosed plans for a FIRE ALARM SYSTEM.The FACP will be located in building 17 ( lower floor of this building is the site community building) , all residential buildings will have their own individual fire alarm annunciator and remote power supply. All residential buildings sprinkler systems will be tied to and monitored by the FACP located in building 17 . The site electricians (Express Electric) are providing building linking conduit/wiring as shown on the included site building linking plan. The SLC and SBUS will be run in a Class A loop as shown. When a Waterflow, Smoke Detector or Pull-station is activated in a residential building, it will annunciate at the annunciator in that specific building and also at the FACP located in building 17 . Residential building occupant notification devices will only activate when an initiating device in that building is triggered, no other building' s occupant notification devices will active. The system has been designed per NFPA 72 , 2013 edition requirements as well as WAC, IBC, IFC 2012 , NEC current and your additional requirements . The building is fully-sprinkled. The system shall monitor by zone activation as well as separate trouble signals . Monitoring shall be provided via UL listed Central Station, The Alarm Center LACEY, WA. Audibility shall be in compliance with NFPA standards . Interior DB shall be 75 DB minimum throughout, (LOW FREQUECNY NOTIFICATION DEVICES TO BE INSTALLED IN RESIDENTAL SLEEPING AREAS . A full service and monitoring agreement is in force for the proper service and maintenance per NFPA requirements . A full pre-test and NFPA form shall be conducted and completed prior to calling the AHJ for acceptance testing. INSTALLATION COMPANY Fire Protection, Inc. 1730 Gibson Rd. Everett, WA 98204 WSCL# FIREPI*021ML UL CERT #608242-002 JOB SITE Park 77 Apartments *Building 9* 20201 77th Ave Ne Arlington , WA APPROVED UL MONITORING COMPANY Alarm Center, Inc. /FPI 4300 3rd Ave. SE Lacey, WA 800-429-0991 UL CERT #902799-02 CONTRACTUAL RESPONSIBLE PARTIES Installation; Monitoring; Service; Testing; Fire Protection, Inc. AMBIENT TEMPERATURES No area with alarm service equipment shall fall below 40 degrees, common areas shall be at 68 degrees per builder AMBIENT NOISE RANGE All areas serviced by the Fire Alarm Control and notification system will be as listed for per UBC listings, per builder. SEQUENCE OF OPERATIONS All Alarm and Trouble conditions shall enunciate at FACP as well as remote notify UL listed Central Station. Zones of alarm shall cause for all notification circuits to activate, send alarm zone to CS, re-dispatch to Fire and dispatch FPI runner service. Trouble and supervisory signals shall transmit to CS which will dispatch FPI runner service to site, (no notification circuits shall activate. ) On site emergency contact personnel shall be notified. Wet Waterflow ALARMS shall be retarded by a period of not more than 45 seconds . Low air shall activate at 25lbs, causing for a supervisory signal . A short on FACP smoke, Waterflow Switches, (wet and dry) and pull station shall cause a alarm. Shorts on PIV, tamper and Hi-low air zones shall cause a Supervisory condition. Opens on any zones shall cause for a trouble signal . Should you have any further questions, please feel free to contact me directly. David Mow VP of Operations/Designer NICET-3 #120904 CITY OF REDMOND D.O.R. #16-B-141 WA JOURNEYMAN LICENSE #MOW**DDE957M6 FACP FOR ALL BUILDINGS LOCATED IN BUILDING 17 @POTTER P 3 00 P/uS Fire Alarm Control Panel Features • 127 expandable to 381 Analog Addressable Points.Any combination of detectors/modules • 5 Amp Power Supply.Expandable to 315 amps • 2 NAC circuits rated at 3 amps maximum,expandable to 188. • 2 Input/Output(1/0)Circuits for system flexibility rated at 1 Amp . �• each _ • Built-in UL Listed IP Communicator • Built-in email event notification and report capability. • Optional Dual Line Digital Alarm Communicator • System wide synchronization of Potter/AMSECO,Gentex, Cooper/Wheelock,and System Sensor signals. • No twisted or shielded wiring required. • Cabinet will accommodate up to 18AH batteries.Panel will charge up to 55AH. • Capable of Class A or Class B wiring configurations • Built-in NFPA 72 compliant smoke detector sensitivity test • Dead-front cabinet design '' �. • 1000 Event History Buffer V` i NYC Fire Dept. Certificate of Approval Potter/Nohmi Protocol Features S735 7165-0328:0195 6156 • Less than 4 second polling time Product includes a 5 year warranty • LED's visible from 360' • Adjustable Smoke Detector Sensitivity • Adjustable Heat Detector Temperature annunciators,intelligent power supplies and other optional modules. • High Temperature Heat Detector as fixed temp The P-Link will support 31 accessories in any combination.The RA- Drift6075 is a 2 x 16 LCD annunciator.The RA-6500 offers a larger 4 x • Compensation 40 line LCD display that allows points and descriptions to be shown • Maintenance Alerts simultaneously.Intelligent remote power supplies repeat the P-Link data • Day/Night Mode and can be mounted 6,500 feet from reach other.P-Link devices such as the RLY-5 relay module,SPG-1000 serial parallel gateway and DRV-50 Description LED driver can be mounted anywhere in the chain of communication with a maximum of 31 of each P-Link devices.A total of two(2) The P300 is a mid-sized analog/addressable fire alarm control panel SLCE-127 Signaling Line Circuit Expanders(loop cards)may be with a total of 381 points.The points may be any combination of smoke installed in the P300 enclosure,in a remote enclosure such as the AE-8 sensors,heat detectors or modules.This panel has a 5 amp power supply or with a PSN-1000E remote intelligent power supply. that is distributed across two Notification Appliance Circuits(NACs) and two Input/Output(1/0)Circuits. The entire system,including the SLC,NACs and P-Link may be converted with a CA-6075 Class A module.The entire system is The NAC circuits are rated at a maximum of 3 Amps each and the 1/0 programmed using a Windows based computer software and requires circuits are rated for a maximum of 1 Amp each.All of the outputs may the use of a software programming software key. be configured for notification or auxiliary power.In addition,each NAC and Output can be programmed for strobe synchronization and utilizes The P300 can communicate to a monitoring station using the on board Quadrasync for strobe synchronization across circuits of various brands. Ethernet connection to an IP communicator or using optional UL listed The 1/0 may also be programmed for a dry contact input such as a water UD-1000 traditional two line alarm communicator.The UD-1000 flow switch or pull station. connects to the main board and has two phone line jacks provided. The IP communicator uses a RJ-45 connection and when connected The cabinet will hold two 12 volt,8 amp/hour batteries or two 12 volt, to the intemet may be programmed to E-mail system status,history 18 amp/hour batteries.The system when fully loaded will charge 55 reports,reminders and the configuration file.The panel may be updated amp/hour batteries.Anything larger than 18 amp/hour will require an remotely using the LTD-1000.If the Ethernet connection is needed external battery cabinet the SSU-00050. remotely,the FCB-1000 fire communication bridge may be installed to The panel has the Potter P-Link connection for expansion with remote allow the Ethernet connection to be installed in a rack. Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • wwpottersignal.com P'�O�IUsJ w. #8830035-REV A PAGE 1 OF 4 08/12 (E) POTT ER P 3 00 Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 381 addressable devices or modules in any combination.The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PSA Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PSHA Combination Analog Photo Electric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135'Fahrenheit heat detector FHA Analog Fixed Temperature Heat Detector that is selectable from 135'F to 185°F RHA Analog Rate or Rise Heat Detector that has a fixed temperature selection from 135°F and 174°F and also will alarm if the temperature increase 12-15°F in one minute DDA Addressable Duct Smoke Detector AB-6 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors AB-4 4"round base that may be mounted to an electrical box and wired for connection to the above sensors AIB Isolater base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop ARB Addressable Relay Base that contains two relays controlled by the SLC.One relay is rated at 8 amps at 240 VAC/30VDC and the other is rated at 2 amps 240 VAC/30 VDC ASB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call. Modules Device Description MCM Miniature Contact Module provides a small foot print contact module for mounting inside an enclosure. APS-SA Single Action Addressable Pull Station APS-DA Dual Action Addressable Pull Station SCM-4 Single Contact Module is a standard contact module with an LED that mounts into a 4"square electrical box. DCM-4 Dual Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. TRM-4 Twin Relay Module provides two form C relays that simultaneously active when the module is triggered by the control panel. Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC. MOM-4 Monitored Output Module is a power switching module that monitors the circuit that is controlled by the control panel. CIZM-4 Conventional Input Zone Module is used to connect conventional smoke detectors to the system that receive their power from the module.This module is like a conventional zone on the SLC. SCI Short Circuit Isolater interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • www.pottersignal.com P"�O�A'SP v #8830035-REV A PAGE 2 OF 4 08/12 (E) POTT ER P 3 00 Fire Alarm Control Panel SLC Features RA-6075—2 x 16 LCD annunciator with a key pad in a locked metal enclosure. The Potter/Nohmi protocol is a digital protocol with a proven design for reliability and noise immunity.The system does not require special RA-6500—4 x 40 LCD annunciator with a key pad in a locked metal cable or conductors for connection of the Signaling Line Circuit as enclosure long as the cable is compliant with NFPA 70 and NFPA 72.The system LED-16—16 LED annunciator with common indicators in a locked allows for Class A or Class B installations as well as"T-Taps." metal enclosure The total polling time for the protocol is about four(4)seconds which PSN-1000(E)—10 amp,remote intelligent power supply with 6 NACs, allows two polling cycles in the ANSUUL 864 requirement of alarms 2 I/Os and a P-Link repeater reporting in less than ten seconds.Each loop is capable of 127 points with the exception of the P100 and P200. CA-6075—Class A convertor that converts the SLC,NACs and P-Link connection Sensor Features UD-1000—UL listed,Dual line telephone alarm communicator The sensors through the fire alarm control panel provide a real DRV-50—LED driver expander,used to connect up to 50 LEDs in a time status as to the condition of the system.The smoke detector graphic display sensitivity,heat detector temperature level and drift compensation FCB-1000—Fire communication bridge,provides remote mounting of as all programmable options.The system also allows for a day/night the Ethernet connection mode where the panel automatically adjusts the sensitivity depending on the time of day.To assist in the reduction of false alarms,the smoke FIB-1000—Fiber interface module,used to extend P-Link to multi- detectors also have a maintenance warning that sends a trouble signal mode fiber(2 required) when a detector is dirty to the point that it can no longer maintain the RLy--5—Relay module,provides 5 form C relay contacts rated at 3.0 programmed sensitivity. amps 24VDC/125AC User Interface SPG-1000—Serial parallel gateway,allows for the connection to a serial or parallel printer The fire alarm control panel has a 4 x 40 LCD display to provide information to the system status.The keypad has navigation keys The FIB-1000,FCB-1000 and the SPG-1000 maybe installed in the t stacker bracket or ordered with the optional rack mount enclosure.o allow manipulation of the Menu on board the panel.The panel is shipped standard with the following LEDs: AE-8—Eight card expansion cabinet • AC Power—Green AE-14—Fourteen card expansion cabinet • Alarm—Red Ethernet/I.P. Connection • Earth Fault—Amber The P300 is shipped standard with an Ethernet connection.This • Supervisory-Amber connection is the programming port and may be connected to a building • Silenced-Amber Wide Area Network(WAN)or Local Area Network(LAN).Once connected to the Internet,the panel may be selectively programmed to • Trouble-Amber e-mail alarm conditions,trouble conditions,supervisory conditions,test, The common buttons include a Silence,Reset,Acknowledge and Drill. Event History and detector status.An e-mail may be sent to the panel All of the buttons are accessible once the locked door is opened. and the panel will e-mail the event history,detector status,configuration file or server status to an authorized E-mail account.In addition, P-Link reminders may be set to send an e-mail for service,testing or other The P300 has a proprietary communication protocol that communicates conditions. through a RS-485 connection to field devices.Up to thirty-one In addition,the Ethernet connection is UL listed as an IP communicator. (31)devices may be connected to a single P-Link connection.The The IP communicator is listed to report to the UL listed Sur-Gard III P-Link includes the communication terminals and regulated 24 VDC IP receiver.The IP communicator replaces the traditional less reliable connection for the field devices.The field devices may be any of the alarm communicator transmitter that utilized telephone lines.The IP following: communicator is an active method of connection and communication to SLCE-127-Analog/Addressable loop expansion module(maximum of 2 the monitoring station. per P300) Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • wwpottersignal.com P'��PlusZ* w. #8830035-REV A PAGE 3 OF 4 08/12 (E) POTT ER P 3 00 Fire Alarm Control Panel Specifications 18.91" 17.60" Electrical Specs:AC Mains O O TOP o 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @ 240 VAC 50/60 HZ 4.41" 3.75" DEPTH Battery p 0 130 mA Standby 220mA Alarm b • 5 Amps power for NACs,I/O and P-Link • 3 Amps per NAC,regulated a • 1 Amp per I/O circuit,regulated �e c7 O • Battery Charger range 8-55 Ah • Battery Charger voltage 27.3 VDC • P-Link maximum current of 1 Amp • Panel holds(2)8AH or(2) 18AH batteries LEFT SIDE RIGHT SIDE Cabinet • 16 gauge cold rolled steel with removable BOTTOM ` locked door • Dimensions—18 15/16"W x 27 5/16"H x 4 7/16"D • Dead front to cover all electronics • Lexan viewing window Temperature and Humidity This fire alarm control is listed and approved for operation in an indoor application with temperature range fluctuations of 32'to 120'(0°C to 49°C) with a maximum humidity of 93%non-condensing.The ideal temperature is 77°F +/- 10°F(25°C+/-5°C). Standards The P300 series fire alarm control panel complies with the following standards and codes. • NFPA 13,70 and 72 • ANSI/UL 864 0 Local(L),Remote Station(RS),Central Station(CS),Propriety(PPU),Auxiliary(AUX) 0 Type of Service:Automatic(A),Manual(M),Water flow(WF)Sprinkler Supervisory(SS) 0 Type of Signaling:Digital Alarm Communicator(DAC),March Time(March),Non Coded(NC),Reverse Polarity(Rev Pol),Other Technologies(OT) • IBC 2000,2003,2006,2009,2012 Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • wwpottersignal.com P'h�T PUF'J w. #8830035-REV A PAGE 4 OF 4 08/12 POTTER RA-6075 The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Features Standby Current 20 mA Alarm Current 25 mA Operating Temperature 0°C-49°C(32°F-120°F) 10%-93% @ 30°C(86°F)non-condensing 0 © humidity Maximum Wire Length 6500 FT ® © Maximum Annunciators 31 - Dimensions(WxHxD) 8"x 6-1/4"x 1-5/8"(Cabinet) Wire Gauge 14 AWG-22 AWG Display 2 lines x 16 characters Product includes 5 year warranty U� LISTED S2930 7165-0328:0195 Description Installation The RA-6075 is a LCD remote annunciator for the PFC-6075 and The RA-6075 is connected to the PFC-6075 using a four wire RS-485 PFC-6030 addressable fire control panel.The RA-6075 communicates connection.The connection is power limited and supervised.Up to using a RS-485 connection to the main panel providing common thirty-one(31)RA-6075 LCD annunciators can be connected using indication of Alarms,Supervisory,Trouble and other system status and Class B or Class A wiring.Class A wiring requires an optional Class A control functions. Expander. The RA-6075 features a 32 character, 16x2 LCD display with LED's for Power,Alarm,Supervisory,Trouble,and Silenced conditions. , It can be mounted on a single gang electrical box or a four square electrical box.The annunciator is enclosed in a sheet metal enclosure Instal!inac!cord!anc!e with compatib7fir,alarm panel. and has a Potter lock securing the keypad. Figure 1:RA-6075 Class B Wiring Example Figure 2:RA-6075 Class A Wiring Example To the next annunciator 4CA-60775 + m + a P-LINK + a + A B + + + + Panel + + + + + + Panel + + Connection Remote -LIN + Annunciator Connection + Remote -LIN< Annunciator m Q m Oa O a + Q O Remote O Remote Annunciator Annunciator Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#5406077-REV B-1 PAGE 1 OF 2 9/11 (E) POTTER RA-6075 The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Address Settings The RA-6075 address is set by dip switch S 1 located on the back of the RA-6075.The address must be set in the range of 1 to 31 to be recognized by the control panel. Figure 3:RA-6075 Class A(back panel view) O ❑ 0 0 OWWWW .-9. O 0 © A on ® 9 ® + Al O o Dip Switch Settings Refer to the table below for dip switch settings per Annunciator Address. Annunciator Dip Switch Settings Annunciator Dip Switch Settings Address SW-1 SW-2 SW-3 SW-4 SW-5 Address SW-1 SW-2 SW-3 SW-4 SW-5 1 On Off Off Off Off 17 On Off Off Off On 2 Off On Off Off Off 18 Off On Off Off On 3 On On Off Off Off 19 On On Off Off On 4 Off Off On Off Off 20 Off Off On Off On 5 On Off On Off Off 21 On Off On Off On 6 Off On On Off Off 22 Off On On Off On 7 On On On Off Off 23 On On On Off On 8 Off Off Off On Off 24 Off Off Off On On 9 On Off Off On Off 25 On Off Off On On 10 Off On Off On Off 26 Off On Off On On 11 On On Off On Off 27 On On Off On On 12 Off Off On On Off 28 Off Off On On On 13 On Off On On Off 29 On Off On On On 14 Off On On On Off 30 Off On On On On 15 On On On On Off 31 On On On On On 16 Off Off Off Off On PRINTED IN USA MFG.#5406077-REV 13-1 PAGE 2 OF 2 9/11 CPOTTER PSN-1000(E) The Symbol of Protection POWER EXPANDER Features 10 Amp Power Supply • 3 Amps,regulated per NAC • 6 NACs Class B or 3 NACs Class A • 2 dry contact inputs • Fully programmable and monitored through control panel _ I Isolated P-Link repeater connection,Class A or B • Up to 31 power supplies per control panel with system wide sync • Quadrasync feature synchronizes strobes from Potter/AMSECO, Gentex,Cooper-Wheelock and System Sensor. ®RPOTTFR PSN-1000 Compatible with all Potter PFC-6000 series fire alarm control panels. Ines➢pool of Frowpon P.—Supply --. Electrical Specs • 120/240 VAC Input at 50/60 HZ • 5.1 Amps/3.0 Amps max draw • Standby Current 60 mA • Alarm Current 200 mA U` S2930 7165-0328: 0195 Product includes a 5 year warranty Description The PSN-1000 series is a UL listed intelligent 10 amp notification power supply and P-Link(RS-485)repeater.The power supply connects to the P-Link bus from the control panel and is operated and supervised from the panel.The power supply may be installed 6,500 feet from the control panel.The PSN-1000 then repeats the P-Link communication for another 6,500 feet. The power supply has six(6)Class B or three(3)Class A power outputs.Each output is regulated and power limited with a 3 Amp maximum rating.In addition,the PSN-1000 has two(2)programmable dry contact inputs.The dry contact inputs are Class B,supervised inputs. The power supply operates on either 120 or 220 VAC power and has a regulated 24 VDC output.In addition,the panel can charge up to 55 AH batteries and will house 18 AH batteries.The cabinet is constructed out of 18 gauge cold rolled steel with a durable red powder coat finish.A standard Potter key lock is provided for securing the door.Electrical conduit knockouts are provided on the sides and top providing installers with multiple options for installing conduits and providing proper power separations. The PSN-1000 is a self contained intelligent power supply/P-Link repeater complete with cabinet.The PSN-1000E is the intelligent power supply/P-Link repeater with additional cabinet room for the exclusive Stacker Bracket for SLCE-127 loop expanders.Both cabinets include space for 18 AH batteries. The power supplies are programmed and controlled through the main control panel P-Link bus.The panel displays any troubles or off normal conditions of the power supply and the events are stored in the panel history buffer. Each output can be independently configured to provide one of four synchronization patterns,constant power,ANSI temporal Code 3 or Door Holder power.The panel can be configured to synchronize Potter/AMSECO®,Gentex®,Cooper Wheelock®and System Sensor®. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830032-REV B PAGE 1 OF 2 09/14 (E) POTTER PSN-1000(E) The Symbol of Protection POWER EXPANDER 18.91" 17.60" 4 0 0 TOP w 0 4.41" 3.75" DEPTH O O 0 0 0 N O O O 0 LEFT SIDE RIGHT SIDE BOTTOM Dimensional drawings showing the cabinet in all three planes. Knock out locations. PRINTED IN USA MFG.#8830032-REV B PAGE 2 OF 2 09/14 4, �� SYSTEM � SENSOR t 41, Photoelectric Smoke Detectors System Sensor i3-series smoke detectors represent significant advancement in conventional detection. 3 The i3 family is founded on three principles:installation TM ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its •Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included with heads).The large wire entry port and in-line terminals provide Large wire entry port ample room for neatly routing the wiring inside the base.The base •In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single-gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,i3 boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock'action. •Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features •Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and •Built-in remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize nuisance alarms.2-wire i3 detectors can generate a remote LED- indicated maintenance and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 •Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i3 •Wide-angle,dual-color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof i3 Loop testing via EZ Walk feature detectors in terms of percent-per-foot obscuration. • •Built-in test switch Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on 2-wire P detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. T istin s M MEA MSFMTPROVED approved approved cC I,us I W6 7272-1653:152 290-01-_ 3C93? (-L3)Smoke Detector Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 1357 (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5 V Maximum:35 V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 NA maximum average;4-wire:50 NA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V Peak Standby Current 2-wire:100 uA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 1207(0°C to 49°C);2WT-B and 4WT-B:327 to 1007(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 1357(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:417(5°C) Sensitivity 2.50/o/ft nominal Input Terminals 14 to 22 AWG Mounting 3'/2-inch octagonal back box 4-inch octagonal back box Single-gang back box flinch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12 V,23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V,23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter f_ SY TE� m2cha system Sensor. �/ 3825 Ohio Avenue•St.Charles, L 60174 Product specifications subjec[to009 System Sensotice.Vsit rystemsensoccom for SENSOR Phone:800-SENSOR2•Fax:630-377-6495 urrentproductinformat5-03180i7-6/09 latest version okhis data sheet. A06-0318-007.6/09•#2169 PULL STATION SERIES (E) POTTER DIE-CAST METAL The Symbol of Protection MANUAL PULL STATIONS • UL and cUL Listed,FM Approved,CSFM Listed,MEA ' Approved,ADA Compliant • Single or Dual Action • Terminal connectors PULL UOWN Big . 10 Amp Snap Action Switch Gold plated SPST contacts Optional auxiliary contacts Mounts on standard single gangbox • Surface backboxes available • High-gloss red enamel finish • Glass breakrod DUs FMo �5 Made in the U.S.A. LISTED Description Engineering Specifications The Potter Pull Station Series offers a complete line of die-cast pull The contractor shall furnish and install the Potter series of pull stations for a variety of applications focusing mainly on fire alarm stations as indicated.The pull station shall be die cast construction systems.The pull stations are available in single or dual action with a"T"type pull handle that is ADA compliant.Single action pull models.All of the pull stations have a 10-amp snap action switch and stations shall be a P32-lT.Dual action pull stations shall be the Potter a dedicated terminal block for the ease of wire connections.All of P32-1T-LP.Any manual pull station installed in an outdoor or wet the metal is completely coated to inhibit corrosion and provide for a location shall be a RMS-IT--WP weather proof unit.The contact shall uniform and quality finish. be a single pole,single throw switch rated at 1 amp 30V DC/125V The standard models have a hex key reset,however a key reset is also AC.The device shall have a terminal block for ease of wiring.Once available.The models are available with shallow and deep surface activated,the pull station shall be reset by opening the front cover. mount back boxes and as a weatherproof version. Opening of the cover in a normal state shall initiate an alarm. Operation Specifications The Potter single action series of pull stations operate by pulling Switch Rating: 1 Amp @ 30 VDC the white operating handle straight down and the handle will lock 10 Amps @ 125 VAC into place.The dual action stations require the lifting of the front Pull Station Dimensions: 4-3/4"H x 3-1/4"W x 7/8"D cover and then pulling the white operating handle straight down.The Color:Red with raised white letters,white pull bar with raised red letters stations are reset by opening the front and placing the handle in the For special application manual stations see bulletin#8910014. normal position. For explosion proof manual stations see bulletin#8880014. Ordering Information Type Model Number Stock Number Contact Type P32-1T 1000447 SPST RMS-2T 1000477 DPST Single Action RMS-6T 1000478 DPDT RMS-1 T-KL 1000451 SPST RMS-IT-KO 1000450 SPST,key operated,no pull Weather Proof RMS-1 T-WP 1000401 Dual Action P32-1 T-LP 1000476 SPST Weather Proof Dual Action RMS-IT-WP-LP 1000403 Accessories Notes Dual Action RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1000470 Replacement glass rods(10 per pkg) Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8900097-REV L PAGE 1 OF 1 9/10 P POTT ERS A ka-"Wl' DCM-4 ® The Symbol of Protection Dual Contact Module Features • Single module with dual contact monitoring inputs • Two(2)Class B or one(1)Class A monitoring inputs • SLC Class A(Style 6,7)&Class B(Style4) • Mounts in a standard 4"or double gang box s- S. • Wiring terminals accessible when mounted in box ©E�►•■-�+•�.+o • All wiring terminals accept 22 to 14 AWG li wsiar • Product includes a 5 year warranty ee _.. NOTE: This addressable module does not support 2-wire smoke f zz1,1" zi ;, ci detectors. Stock Number: 1430822 LISTED �zw� S2930 7165-0328:0196 Application Technical Specifications The DCM-4 is compatible with Potter's PFC-6000 series and PFC- Operating Voltage 22.0-24.OV 8500 addressable fire alarm control panels.The DCM-4 is an interface Max SLC Standby Current 325 µA module used to monitor dry contact devices such as sprinkler water Aux Power Required 1mA flow,valve tamper switches,or conventional pull stations.The module is capable of monitoring two separate Class B or one Class A circuits. Max Wiring Resistance of IDC I 100 S2 Max Wiring Cpacitance of IDC 1 µF EOL Resistor 5.lK S2 Description Operating Tempurature Range 32 to 120°F(0 to 49°C) The DCM-4 uses two (2) consecutive SLC loop addresses when Operating Humidity Range 0 to 93%(non-condensing) monitoring two(2)Class B circuits or one(1)address when monitoring 127 units(Class A)or 63 units a single class A(Style D)circuit.The module mounts on either a 4" Max no.of Module Per Loop (Class B) square or double gang box.The module is capable of monitoring two (2)separate class B circuits making it ideal for monitoring sprinkler Dimensions 4.17"(106mm)L X 4.17" waterflow and valve tamper switches when they are located in the same (106mm)W X 1.14"(29mm)D proximity.The DCM-4 includes one red LED to indicate the modules Standard 4"Square or status.In normal condition,the LED flashes when the device is being Mounting Options Double Gang Box polled by the control panel.When a contact is activated,the LED will Shipping Weight 0.6 lbs light continuously and in case of an open circuit,the LED will turn off. Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com 8830008-REV B • 7/14 PAGE 1 OF 2 P POTT ERS OHM/® DCM-4 ® The Symbol of Protection Dual Contact Module Setting the Address Each addressable module, smoke sensor,heat detector and combination sensor/detector must be assigned an address prior to installing the device.The address is set using either the hand held device programmer or the addressing feature on the PFC 6000/PFC 8500 Series control panels.When the DCM- 4 is used to monitor two individual Class B circuits a single device address is assigned,with the second address number assigned automatically by the module assuming the next consecutive address.For example,if the first address number is assigned as"2",the second address number will automatically be assigned as SLC device address"3". Before connecting a device to the SLC loop,take the following precautions to prevent potential damage to the panel or device verify the following: 1.Power to the device is removed 2.Field wiring is correctly installed. 3.Field wiring has no open or short circuits. Installation Using Compatible Electrical Box O e ° ° o e Wiring Diagrams DCM-4 With One Class ACircuit NOl FROM FACP OR C 1 PREVIOUS MODULE S+ ZI S- NO2 TO THE NEXT MODULE F 1 C2 SELECT STYLE D 0000 LED Q Z2 NOTE:END-OF-LINE RESISTOR IS NOT REQUIRED DCM-4 With Two Class B Circuits NOl FROM FACP OR C 1 PREVIOUS MODULE S+ Zl "OHM1/2W S- NO2 TO THE NEXT MODULE ppH1pC2 �000 LED O Z2 SELECT STYLE B 5.1K OHM 1/2W Potter Electric Signal Company,LLC St. Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 www.pottersignal.com :so 9001:2008 1 DESIGNING,MANUFACTURING, 8 DISTRIBUTING QUALITY SYSTEMS 8830008-REV B • 7/14 PAGE 2 OF 2 GENTEX CORPORATION Low Frequency Audible Signal GHLF Applications 24 V D C The GHLF is a high quality, low profile, low frequency audible appliance that offers a dependable audible alarm with a low current draw. The GHLF is ideal for any S E R I E S occupancy that requires notification appliances. The GHLF horn offers a 520 Hz square wave,temporal 3 tone. A jumper selection is available for normal or loud decibel tone. A temporal 4 pattern is available when used with the Gentex GTSM Synchronization Control Module. The GHLF is shipped with a standard 4" metal mounting plate which incorporates the popular Super-Slide°feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The GHLF also features the patented Checkmate°- Instant Voltage Verification feature which allows the installer to check the voltage drop and match it to the blueprint. The GHLF horn is listed to ANSI/UL 464 and CAN/ULC S525, is listed for use with fire Product Listings protective systems and is warranted for three years from date of purchase. SIGNALING Standard Features � • Nominal voltage 24 VDC • Input terminals accept 12 to 18 AWG C&uS :U0= O Unit Dimensions:6-1/8"(15.55 cm)high x • Produces a 520Hz square wave,temporal 3 LISTED 5-1/2"(13.97 cm)wide x 1-5/8"(4.13 cm) tone deep • Jumper selection for normal or loud dBA • ANSI/UL 464 Listed • Super-Slide®Bracket-Ease of Supervision • Temporal 4 pattern available when used • CAN/ULC S525 Listed Testing with Gentex GTSM Synchronization Module • CSFM: Pending • Checkmate°-Instant Voltage Verification • Temporal 4 520Hz measured per Product Compliance • Synchronize horn with Gentex GTSM ANSI/UL 2075 • NFPA 72 Synchronization Control Module • Tamperproof re-entrant style grill and • IBC/IFC/IRC • Prewire entire system,install mounting locking screw(optional use) • Quality Management System bracket,then install signals • Faceplate available in red or off-white is certified to:ISO 9001:2008 Model Number Part Number Nominal Voltage Model Designations: �i •j ' = R=Red Faceplate MEMBER •� GHLFW 904-0530-002 24 VDC W=White Faceplate ASSEMBLED IN GHLFR 904-0531-002 24 VDC All units are plain(no lettering) THE USA Horn Decibel Levels: 24VDC Nominal Horn Horn Current Ratings Reverberant Room Current Ratings(mA) Over Input Voltage Range of 16-33V(mA) Minimum SPL Minimum SPL 24VDC 24VDC 24VFWR 24VFWR Regulated Regulated Regulated Regulated at 10Ft.Per at 10Ft.Per Operating Operating Operating Operating 24VDC Max. 24VDC Max. 24VFWR Max. 24VFWR Max. Horn Mode Operating Operating Operating Operating ANSI/UL 464 ANSI/UL 464 Current Current Current Current Current Current Current Current (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) Temporal 3 520 Hz I 77.8 dBA 1 79.8 dBA 72.1 mA 120.1 mA 104.6 mA 158.4 mA 99.4 mA 155.8 mA 152.1 mA 213.5 mA Temporal 4 520 Hz*1 81.5 dBA 1 83.4 dBA 75.9 mA 116.0 mA 108.1 mA 182.0 mA 100.1 mA 157.2 mA 163.1 mA 235.2 mA O Temporal 4 520 Hz measured per ANSI/UL 2075 NOTES: • Operating temperature:32 to 120 F(0 to 49 C).The GHLF is not listed for outdoor use. • For nominal and peak current across ANSUUL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. RMS current ratings are per ANSUUL average RMS method. ANSUUL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units). For unfiltered FWR ratings,see installation manual. GHLF 24 VDC S E R I E NOTES: UL Listed • THIS APPLIANCE IS NOT RECOMMENDED FOR USE ON CODED OR Control Signal Signal PULSING SIGNALING CIRCUITS Panel S+ s- s- H+ H- S+ s+ s- H+ H- • THE FOUR PULSE TEMPORAL PATTERN(TEMPORAL 4)CAN ONLY BE Supervised 0 0 0 0 OBTAINED ON THIS PRODUCT WHEN USED IN CONJUNCTION WITH Signal Circuit THE GENTEX GTSM SYNCHRONIZATION MODULE 1 + ENO LINE • SEE GTSM CONTROL MODULE MANUAL(550-0632,MANUAL ISSUE RESISTOR DATE(02-01-15)FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. S GTSM MANUAL CAN BE OBTAINED AT WWW.GENTEX.COM/FIRE OR CALL GENTEX CORPORATION AT 1-800-436-8391. DOIMIW x o Lt LOCKING 0 0 o SCREW 0 " (optional) Cho H+ logo RED WIRES �- H! Q BLACK WIRES 6- � O o H- U a O o 00 NORMAL-LOUD o c �`f/ DECIBEL JUMPER. 0 0 FOR LOUD DECIBEL CEED INSTALL JUMPER. SLIDE ONTO BRACK Gentex Checkmate® Gentex Super-Slide® LOCKING Instant Voltage Verification: Mounting Bracket: SCREW It is often necessary to confirm the voltage drop Allows the installer to pre wire the system, (optional) along a line of devices.The access holes are test for system supervision,remove the provided in the back of the terminal block to signal head until occupancy,switch out allow the voltage to be measured directly without Gentex signals without changing removing the device.Typically this would be done mounting brackets and has locking edge at the end of the line to confirm design criteria. connector for snap-in-place installation. Most measurements will be taken using the S+ and S-locations although access is provided to other locations. NOTICE:CARE SHOULD BE TAKEN TO NOT qM SHORT THE TEST PROBES. Architect & Engineering Specifications The alarm horns shall be Gentex model GHLF.The appliance shall be listed with Underwriters Laboratories(ANSI/UL)for use with fire protective signaling systems (ANSI/UL 464) and with CAN/ULC S525 with intended use in fire alarm systems. The GHLF will produce a peak sound output of 88.3 dBA as measured in an anechoic chamber. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power at 24 VDC. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton Important Notice: GHLF-01 GENTEX These materials have been prepared Gentex Corporation Gentex')for informational purposes only,are O necessarily summary,and are not purported to serve as legall advice and should not used s such. Gentex makes no representations and warranties,express or implied,that these materials are complete and CORPORATION accurate,up-to-date,or in compliance with all relevant local,state and federal laws,regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to Fire Protection Products Group•www.gentex.com particular fact patterns.Each persons activities can differently affect the obligations that exist under applicable laws,regulations or rules.Therefore,these materials should be used only for informational 10985 Chicago Drive •Zeeland, Michigan 49464 purposes and should not be used as a substitute for seeking professional legal advice.Gentex will not be 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. CPOTTER MHT 1224 SERIES The Symbol of Protection LOW CURRENT MINI-HORN Features • Single unit is capable of 12 or 24 VDC determined by the input I voltage - Y I I IEI I Unit Dimensions:4.48"(11.38cm)high x 2.84"(7.21 cm)wide x F I 0.5"(1.27 cm)deep Jumper selectable temporal 3 or continuous tone I I I i Horn frequency is 3100Hz I I I I Terminal blocks(12 AWG to 18 AWG) • Low current consumption • Variety of mounting options for new construction and retrofit E applications • Synchronize using the AVSM Series control module • ANSUUL 464 listed for fire protective service • Textured finish high impact plastic faceplate,available in red or off-white Ordering Information Operating Temperature(indoor use only) Stock Number Model Number Model Designations 320 to 120OF(00 to 49°C) 4890001 MHT-1224R R=Red facepalte 4890002 MHT-1224W W=Off-White faceplate 4890003 MHT-1224PR P=Plain 4890004 MHT-1224PW SIGNALING U� LISTED Product includes a 5 year warranty Description The MHT-1224 Series mini-horn is a high quality remote The MHT-1224 can be used on the same sync circuit(AVSM audible signaling appliance that offers dependable remote annunciation. Series Control Module)as other Potter signals.The MHT-1224 Series The MHT-1224 is ideal for applications where a dependable audible is ANSUUL 464 listed for use with fire protective systems. alarm signal is required in applications such as hotels, dormitories, and apartments.The MHT-1224 is listed for use with both filtered and unfiltered power and a jumper is provided to select either temporal 3 or continuous tone. Architect&Engineering Specifactions The alarm horns shall be Potter model MHT-1224.The appliance shall be listed with Underwriters Laboratories(ANSUUL)for use with fire protective signaling systems(ANSUUL 464)and produce a peak sound output of 90dBA or greater as measured in an anechoic chamber.The appliance shall be of solid-state construction and be polarized to operate from 8-33VDC with a 22mA current drain at 24VDC.The appliance shall be provided with 2 terminals,and mount to a variety of single-gang back boxes. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830065-REV A PAGE 1 OF 2 06/13 (E) POTTER MHT 1224 SERIES ® The Symbol of Protection LOW CURRENT MINI-HORN Mini-Horn Wiring UL MHT-1221 MHT-I I 1151I I; WIRING DIAGRAM FOR DUAL CLASS B CIRCUITS WITH A SINGLE AVS"CONTROL MODULE CONTROI PANtI + — + SYNCODULAl10N F A C P MUrAIIE 1MT•t7H ANT•t!N h• lu M SIJI>f kV F.I 'NU IT I INr SIGnn•. tE51STDR CIRI'I ' EOI R SIGNAL CIRCUITS wr-Tti+ rrtfar 1_4Cf< B:-ALK Et,-ACK BLAf,R a., Wiring Diagram EOLR Mini-Horn Wiring Use a screwdriver to break the jumper for a continuous tone. O DO NOT BREAK m JUMPER IF TEMPORAL 3 TONE IS NEEDED. Horn Mode Minimum SPL at 10 Minimum SPL at 10 Reverberant dBA at 10 In Anechoic MHT-1224 Current Ratings feet per ANSI/UL feet per ANSFUL feet per ANSI/UL 464 Room dBA @ I 24 VDC 22 mA 464 at 24 VDC 464 at 12 VDC 10 ft. 24 VDC UL Max 18 mA Temporal 3 81 dBA 78 dBA 78-86 90 12 VDC UL Max 13 mA Continuous 86 dBA 1 83 dBA 78-86 90 NOTES:The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. 1 RMS current ratings are per ANSFUL average RMS method.ANSFUL max current is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units)(8-17 VDC for 12 VDC units).For strobes,the ANSFUL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units)(8 VDC for 12 VDC units).For audibles,the max current is usually at the maximum listed voltage.For unfiltered FAIR ratings,see installation manual. PRINTED IN USA MFG.#8830065-REV A PAGE 2 OF 2 06/13 Effective June 2014 Technical Data TDO01009EN Exceder LED Low Frequency Sounder Strobes and Sounders Description ••�• �.�•�.••� � Eaton's Cooper Notification business has developed the Wheelock . •.•:•;...;•.•;••. Exceder LED Low Frequency Sounder Strobes and Sounders to ;••: meet the new National Fire Protection Association (NFPA) low •:•:;:•:•••• •' frequency sounder requirements for sleeping rooms -NFPA 72 for fire alarm and NFPA 720 for Carbon Monoxide (CO)alarm. In a single ••' device,the Exceder LED Low Frequency Sounders can provide alarm ••.•;:•:;�:�;:•:'•;: signals for dual applications-T3 (Fire)and T4(CO)tones. It is the � first product in the industry to be listed to the audibility requirements �'•:;;;;;:�'• X;�����:;�.� of UL 2034 and UL 2075 for CO applications. H ,., fib :;:;:::,•:•;••;; The Exceder LED Low Frequency Sounder Strobes and Sounders feature multiple 520 Hz modes of operation:T3 (fire),T4(CO), •: �••�••��••�.�.•.�. Continuous,T3/T4 Sync Control. The 520 tone is generated within the appliance itself. When '.•;:;:;:;;;:�;:•.;• the selector switch is set forT3 orT4,the sound pattern is also •.•.••...••.•; generated within the appliance. When the selection switch is set to continuous,the product is listed for coded operations. TheT3,T4 pattern or other pattern must be generated by the FACP according to ....... •.�•..•. •� the alarm condition sensed by the panel (fire or CO alarm). . . . . . When the device is set toT3/T4, the appliance can switch fromT3 to '�' '•"'�'•'•'�' T4 based upon the condition sensed by the FACP and passed to the %•% Wheelock DSM module. ••••.••••.••• 0 0 •. Like the entire Wheelock Exceder LED product line, the Low �.�.•�•.;�;.����; Frequency Sounder Strobes will utilize Light Emitting Diode (LED) N ••;.;•:;;;:•; as the light source—a breakthrough optical design, resulting in best- in-class efficiency that enables material and system cost savings, allowing for a greater number of appliances on the notification appliance circuit and fewer power supplies. All LLFHS strobe models include a 110 candela setting. Providing a sleek aesthetic appearance, the Exceder LLFHS and LLFHN models feature one of the industry's smallest footprints and a sleek, modern, low-profile design. Installers will benefit from its comprehensive feature list, multiple 520 Hz modes of operation, lowest current draw, no tools needed for setting changes, and convenient mounting options.These products are suitable for indoor wall-mount applications.The Sounder and Sounder Strobe models are for 24V operation. Exceder LED Sounder Strobes may be synchronized when used in conjunction with the DSM Sync Modules,Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol.Wheelock synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. The Exceder LED Low Frequency Sounders and Sounder Strobes are UL Listed for indoor use under Standard 1971 and 464 and ULC under S525 and S526. The appliances are Restriction of Hazardous Substances (RoHS)compliant and contain no mercury or other F AIkT* N hazardous substances. Powering Business Worldwide Technical Data TDO01009EN Exceder LED Low Frequency Sounder Strobes and Sounders Effective May 2014 Features Drawings • Meets dual low frequency sounder codes for sleeping rooms in a 4.56 1.29 single device • NFPA 72 for fire alarm • NFPA 720 for CO alarm "'eeeeeaeo • 4 Settings in 1 device 000000000000000 • T3 (fire) o°omoo°o°00000°0°0°°0 o°o mo 000000000000 oo°om • T4(CO) °000°o°o°000°o°o°o°o0 m°m°o°Oo°Oo°O°o°o°o°o°m°u • Continuous (Coded) moeo°o°o°o°o°o°0000°oo°° 6. 10 • T3/T4 °o om o0 00°0°00000 o°°a o o eoo °o0 000 o • Energy efficient °ooaooeoo°0o0000o00° eeeee • Patented LED technology provides industry's lowest current O000000es°o draw • Low-profile design • Smallest footprint with sleek, modern aesthetics • --- t 11 • 110 candela setting I.40-I • Easy-to-install • Finger slide switches—No tools needed for setting changes • Built-in level adjustment feature and snap-on grille cover Figure 1.Wall Low Frequency Sounder Strobe • IN/OUT screw terminals using#12 to#18 AWG wires • Mounting Options include Exceder LSPKBB _ backboxes and 4" square backboxes o°000°0000°o 0o0o0aes°°a°o°0 • Strobe synchronization components o o ¢ 00000 0 0 0 Y p o o°o°OpOo°o°o°0°a°o o • Meet synchronizing standards with Wheelock's DSM Sync mom 00 oaop0°o°o°o°°o m Modules or PS-6/8 Power Supplies ®000000°°000°°o$00000 pP m0m0o0o00000000o0o00° m o 0 0 0 0 0 0 0 0 0 m o0 o°o00 o°o°o°o°o°o°o° • Compliance o°m°000°000°0°00000 • UL 2034, UL 2075, UL 1971, UL 464, ULC S525, ULC S526 °o°m o°°o°Op°o°00000°®oo° °aooee000000oee0000 • California State Fire Marshal (CSFM) o o eeeee o o o°aoeeeeeepe0o • ADA/NFPA/ANSI/OSHA 000 • RoHS Note: All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. A WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION Figure 2.Wall Low Frequency Sounder INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT.VISIT WWW.000PERNOTIFICATION.COM OR CONTACT Table 1. Horn Strobe Current Draw COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. ULIULC Max Current a FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR Exceder LED Sounder Strobes 24VDC WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, 16-33 Volts WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR Model Horn Setting 110 cd DEATH TO YOU AND/OR OTHERS. LLFHS Continuous 0.292 Code 3 0.292 Code 4 0.292 General Notes Code 3/Code 4 0.292 • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range:' Note that NFPA-72 specifies a Table 2. Horn Only Current Draw flash rate of 1 to 2 flashes per second and ADA Guidelines specify ULIULC Max Current a a flash rate of 1 to 3 flashes per second. Exceder LED Sounders 24VDC • All candela ratings represent minimum effective Strobe intensity Model Horn Settings 16.0-33.0 based on UL 1971. LLFHN Continuous 0.113 Code 3 0.113 Code 4 0.113 Code 3/Code 4 0.113 2 EATON www.eaton.com Technical Data TDO01009EN Exceder LED Low Frequency Sounder Strobes and Sounders Effective May 2014 Table 3. Sound Output (SPL)- UL Table 4. Sound Output (SPL)- ULC LLFHS/LLFHN 24V LLFHS/LLFHN Reverberant dBA per UL 464 dBA per ULC S525-07c Description 16.OV 24.OV 33.OV Description 16.OV 24.0V 33.OV Continuous 80 80 80 Continuous 80 80 80 Code 3 76 76 76 Code 3 80 80 80 Code 4 b 85 85 85 Code 4 80 80 80 Code 3/Code 4 76 76 76 Code 3/Code 4 80 80 80 Table 5. Specification &Ordering Information Sync w/DSM or Model Strobe Candela Red White Lettering Wheelock Power Supplies Sounder Strobes LLFHSR 110 X FIRE X LLFHSW 110 X FIRE X LLFHSR-AL 110 X ALERT X LLFHSW-AL 110 X ALERT X LLFHSR-CO 110 X CO X LLFHSW-CO 110 X CO X LLFHSR-N 110 X No Lettering X LLFHSW-N 110 X No Lettering X Sounders LLFHNR-AL X ALERT X LLFHNW-AL X ALERT X LLFHNR-CO X CO X LLFHNW-CO X CO X LLFHNR-N X No Lettering X LLFHNW-N X No Lettering X Accessories Description Red White LSPKBB-R 0756 Exceder LED Backbox X LSPKBB-W 0757 Exceder LED Backbox X Table 6. Specifications Physical Material Red or white textured UV stabilized,colored impregnated engineered plastic. Exceeds 94V-0 UL flammabil- ity rating Weight 1.10 lbs. Lens Light Emitting Diode(LED)in a rugged Lexan lens Dimensions 6.1"H x 4.56"W x 1.4" D Operating Temperature Indoor:33.8°F to 120.2°F WC to 49°C)and maximum humidity of 85% Mounting&Wire Connections Mounting(indoor only) Wall-mount applications only. Exceder LSPKBB backboxes or to 4" square backboxes Wire Connections #12 through#18 AWG Power&General Operating voltage 24 VDC: 16-33 VDC Strobe Output Rating UL 1971: 110 candela output Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules, PS-6/8 Power Supplies, using Wheelock patented sync protocol Temporal Audible Pattern Continuous, Code 3, Code 4 or Code 3/Code 4 Sync Control. The Code 3 temporal pattern (1/2 second on, 1/2 second off, 1/2 second on, 1/2 second off, 1/2 second on, 1-1/2 off and repeat) is specified by ANSI and NFPA 72 for standard emergency evacuation signaling. The Code 4 temporal pattern (four cycles of 100 milliseconds 10 percent"on"and 100 milliseconds 10 percent"off;'followed by 5 seconds 10 percent"off) is specified by NFPA 720. a RMS current ratings are per UL maximum RMS method.UL max current rating is the maximum RMS current within the listed voltage range(16-33A. For strobes the UL max current is usually at the minimum listed voltage. For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings,see installation instructions. b Code 4 setting rated per UL 2075, UL 2034. c For dwelling use only. 3 EATON www.eaton.com Technical Data TDO01009EN Exceder LED Low Frequency Sounder Strobes & Sounders Effective May 2014 Architects and Engineers Specifications backboxes and to standard 4" square backboxes. The sounder and The low frequency sounders and sounder strobes appliances shall sounder strobe shall incorporate a mounting plate with a snap-on be Wheelock® ExcederTm LED Series LLFHN Sounder and LLFHS grille cover and shall mount to standard electrical hardware requiring Sounder Strobe for wall-mount applications with a low-profile design no additional trimplate or adapter. Removal of an appliance shall or approved equals.The sounders shall be UL Listed under UL 464 result in a supervision fault condition by the Fire Alarm Control Panel (FACP). All notification appliances shall be backwards compatible. for Fire Protective Service and to the requirements of UL 2034/UL 2075 for CO applications and ULC S525. Sounders equipped with The Series LLFHN wall model shall have a low profile measuring strobes shall be listed under UL 1971 for Emergency Devices for the 6.1" H x 4.56"W x 1.29" D.The Series LLFHS wall model shall have Hearing-Impaired and ULC S526.The Series shall be Restriction of a low profile measuring 6.1" H x 4.56"W x 1.4" D. Finish shall be Hazardous Substances (RoHS) compliant and contain no mercury or red or white. Special lettering,ALERT, CO and No lettering, shall be other hazardous substances. In addition, the sounder strobes shall available. meet the requirements of FCC Part 15.All inputs shall be compatible When synchronization is required, the appliance shall be with standard reverse polarity supervision of circuit wiring by a Fire compatible with Wheelock's DSM Sync Modules, PS 6/8 Power Alarm Control Panel (FACP)with the ability to operate from 16 to 33 Supplies,or other manufacturer's panels with built-in Wheelock VDC. Patented Sync Protocol.The strobes shall not drift out of synchro- nization at any time during operation. If the sync protocol fails to The Series LLFHS Sounder Strobe shall produce a flash rate of one operate,the strobe shall revert to a non-synchronized flash-rate and (1)flash per second over the Regulated Voltage Range and shall still maintain (1)flash per second over its Regulated Voltage Range. incorporate a Light Emitting Diode (LED)as the light source with a The appliance shall also be designed so that the audible signal may rugged Lexan®lens.The Series shall be of low current design.The be silenced while maintaining strobe activation when used with strobe intensity shall have a 110 candela for wall mount applications. Wheelock patented sync protocol. The audible shall have a minimum of four(4) 520 Hz modes of operation:T3 (fire),T4(CO), Continuous,T3/T4 Sync Control. UL 1971, UL 464, ULC S525, ULC S526, CSFM, FCC, RoHS The Series LLFHS and LLFHN shall be designed for indoor surface or flush mounting. Mounting options shall include LED speaker Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. 111=11A WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Cooper Notification 273 Branchport Ave. Long Branch,NJ 07740 CooperN otif i cation.com ©2014 Eaton All Rights Reserved Eaton is a registered trademark. - Printed in USA Publication No.TDO01009EN All other trademarks are property Powering Business Worldwide June 2014 of their respective owners. pp- 000 COOPER Notification EJCED _ Strobe, Horn Strobe, and Horn Notification Appliances - Ceiling Wall Description: The Wheelock°Exceder`Series of notification appliances feature a sleek modern design that will please building owners with reduced - Save up to 48% in current draw* total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes,voltage test - Up to 9 models now in 1 appliance points, 12/24 VDC operation,universal mounting base and multiple mounting options for both new and retrofit construction. - Save up to 14% cost of installation** The Wheelock°ExcederTm Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe models feature an industry first of 8 candela settings on a single U Sleek Modern Aesthetics appliance.Models with an audible feature 3 sound settings(90,95, 99 dB).All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. C40 Finger Slide Switches Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock° ExcederTm Series of wall and ceiling notification Voltage Test Points appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting Multiple Voltages base can be pre-wired to allow full testing of circuit wiring before ' the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt,dust,paint 3 Audible Settings and damage to the contacts. The Contact Cover also acts as a 90,95,99 dB shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while 8 Candela Settings *** it is on the UMB. When the Contact Cover is removed the circuit Wall-15/1575/30/75/95/110/135/185 will show an open until the appliance is installed.The UMB allows Ceiling-15/30/60/75/95/115/150/177 for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra Universal Mounting Base *** secure installation, while the ceiling models provide a captivated Ceiling and Wall screw to prevent the screw from falling during installation. UU Mounts to 5 Backbox Types Compliance Environmentally Friendly -UL 1971, UL 464, ULC, CSFM, FM Low Current Draw -ADA/NFPA/ANSI/OSHA -RoHS Compatibility and Requirements -Synchronize using the Wheelock°Sync Modules or panels with built-in Wheelock°Patented Sync Protocol -Compatible with UL"Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage -Strobes produce 1 flash per second over the"Regulated Voltage" range Compared to competitive models ""Patented Compared to previous models NOTE:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range". •All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 1207(0°C to 49°C)and maximum humidity of 93%(±2%)UL 464(85%UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances(Indoor use only). Low Current Draw = FewerPower • • Strobe Ratings per UL Standard 1971 UL Max Current* 24 VDC/24 FWR 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 0.253 0.110 0.140 STC 8.0-33.0 0.061 0.085 0.103 0.135 0.163 0.182 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 &Anechoic at 24 VDC AnechoicUL Max Current*at •• •:A 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 10.125 AnechoicUL Max Current*at •:A 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.272 0.122 AnechoicUL Max Current*at •• •:A 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 Horn Ratings per UL Anechoic Model Regulated Voltage 99 dB 95 dB 90 dB Range VDC HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 *UL max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage(33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Sync w/ Model Strobe DSM or 12/24 VDC* Mounting Candela Wheelock Power Options Supplies HSR 15/1575/30/75/95/110/135/185 X X UMB** ' HSW 15/1575/30/75/95/110/135/185 X X UMB** H S RC 15/30/60/75/95/115/150/177 X X UMB** ' HSWC 15/30/60/75/95/115/150/177 X X UMB** STIR 1511575/30/75/95/110/135/185 X X UMB** STW 15/1575/30/75/95/110/135/185 X X UMB** STRC _ 15/30/60/75/95/115/150/177 X X UMB** STWC 15/30/60/75/95/115/150/177 X X UMB** HNR X X UMB** HNW X X UMB** HNRC .. X X UMB** HNWC 117 X X UMB** *12 VDC models feature 15&15/75 settings **UMB=Universal Mounting Base Model Legend HN = Horn A =Agent Lettering - ST = Strobe (Strobes only) 4r HS = Horn Strobe AL=Alert Lettering C = Ceiling Mount (Strobes only) W =White N = No Lettering R = Red (Strobes only) Example 1: STRC=Strobe,Red,Ceiling Mount / Example 2: HSR=Horn Strobe, Red,Wall Mount / Example 3: HSW=Horn Strobe,White,Wall Mount ' r Example 4:STW-AL=Strobe,White,Wall Mount,Alert Lettering ■ p g Example. Example: HSWC • 1 *UMB Contact Cover NOTE: Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Cooper Notification standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock° ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design. Where Multi-Candela appliances are specified,the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g.ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe,ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP). The mounting base shall be the same base among all horn, strobe, horn strobe,wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24"H x 4.58"W x 2.19"D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63" D. Series HNC ceiling shall have a diameter of 6.68"x 1.50" D. When synchronization is required,the appliance shall be compatible with Wheelock®'s DSM Sync Modules,Wheelock®Power Supplies or other manufacturer's panels with built-in Wheelock®Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate,the strobe shall revert to a non-synchronized flash-rate and still maintain(1) flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock®synchronization protocol. Wall Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS W WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder- Spec Sheet 5/13 NJ Location 273 Branchport Ave. Long Branch, NJ 07740 800-631-2148 www.coopernotification.com Cooper Notification is Wheelock' MEDC SAFEPATH® WAVES { COOPER Notification S-24 & HS-24 CPOTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Features • 24VDC units have field selectable candela options of 15,30,60, 75,& 110 • Super-Slide®Bracket-Ease of Supervision Testing • Checkmate®-Instant Voltage Verification • Synchronize strobe and/or horn with AVSM Control Module • Prewire entire system,install mounting bracket,then install - signals f, _ — Documented lower installation and operating costs Input terminals accept 12 to 18 AWG Switch selection for high or low dBA Switch for chime,whoop,mechanical and 2400Hz tone Tamperproof re-entrant style grill R I I I I I I I I Switch for continuous or temporal 3 tone(not available on whoop tone) • Surface mount with the AVBB(Surface Mount Back Box) • Silence audible while visual appliance will remain flashing(for use in accepted jurisdictions) • Faceplate available in red or off-white Operating Temperature • 320F to 120OF(0°C to 49°C).The HS and S Series are not listed for outdoor use. Unit Dimensions • 5"(12.7 cm)high x 4.5"(11.43 cm)wide x 2.5"(6.35 cm)deep U� LISTED S3247 Description The S-24/HS-24 Series is a low profile strobe and horn/strobe This Series is shipped with a standard 4" metal mounting combination that offers dependable audible and visual alarms and the plate which incorporates the popular Super-Slide®feature that allows absolute lowest current available. the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without The S-24 & HS-24 Series 24VDC offers tamperproof field any screws showing. selectable candela options of 15,30,60,75,and 110 candela. The S-24/HS-24 also features the patented Checkmate® - The Strobe and Horn/Strobe offers a continuous or sync Instant Voltage Verification feature which allows the installer to check temporal three in 2400Hz and mechanical tone, a chime and whoop the voltage drop draw and match it to the blueprint. tone.All tones are easy for the professional to change in the field by the use of switches. The S-24&HS-24 Series appliances are ANSI/UL 464 and ANSI/TJL 1971, listed for use with fire protective systems and are The S-24 & HS-24 Series has a minimal operating current warranted for three years from date of purchase. and has a minimum flash rate of 1 Hz regardless of input voltage. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 1 OF 4 06/13 S-24 & HS-24 (E) POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Tone Switch Locations TONE SWITCH POSITION 3 4 5 ®o Mechanical Temporal 3 ON ON ON �® 1, Mechanical-Continuous OFF ON ON 2400Hz-Temporal 3 ON OFF ON ® S+ 2400Hz-Continuous OFF OFF ON S- Chime-Temporal 3 ON ON OFF -® H+ � Chime-Continuous I OFF ON OFF Whoop I ON OFF OFF Whoop OFF OFF OFF NOTE: • Switch Positions 1 and 2 in the OFF position to select isolated horn and strobe power inputs • Switch Position 6 ON=HIGH dBA • Switch Position 6 OFF=LOW dBA Super Slide®Mounting Bracket Checkmate®Instant Allows the installer to pre-wire Voltage Verification the system,test for system It is often necessary to confirm the voltage supervision,remove the signal drop along a line of devices.The access head until occupancy,switch holes are provided in the back of the out signals without terminal block to allow the voltage to be changing mounting brackets measured directly without removing the and has locking edge connector device.Typically,this would be done at the for snap-in-place installation. end of line to confirm design criteria.Most - measurements will be taken using the S+ and S-locations althouhg access is provided to other locations. NOTE:Care should be taken to not short the test probes. Candela selection slider switch. Depress center and slide switch to desire brightness level. r- T Break off pin and insert l S into hole at the bottom of .a the selector to lock candela setting.Signal must be removed from bracket and pin pushed forward from backside out of hole to change candela. To remove bezel,grip both sides of bezel and pull in a download and outward motion. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 2 OF 4 06/13 S-24 & HS-24 CF POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES S-24 24 VDC Selectable Candela,Low Profile Evacuation Strobe Model Part Nominal Candela Number Number Voltage (ANSI/UL 1971) S-24WR I 4890010 24 VDC 15,30,60,75, 110 S-24WW 4890011 24 VDC 15,30,60,75, 110 HS-24 24 VDC Selectable Candela,Low Profile Evacuation Horn/Strobe Model Part Nominal Candela Reverberant dBA at In Anechoic Room Number Number Voltage (ANSFUL 1971) 10 ft.,per ANSI/UL 464 dBA at 10 ft. HS-24WR 4890030 24 VDC 15,30,60,75, 110 62-82 100 HS-24WW 4890031 24 VDC 15,30,60,75, 110 62-82 100 S-24&HS-24 Product Strobe Current Ratings(mA) 24 VDC(16-33 Volts) Model Designations: W=Wall Mount Candela 24 VDC UL Maxi R=Red Faceplate W=White Faceplate 15 cd 30 mA 42 mA 30 cd 35 mA 58 mA All units are available in plain(no lettering). Plain units are non-returnable. 60 cd 66 mA 97 mA 75 cd 80 mA 116 mA ALERT bezel available for order. 110 cd 103 mA 161 mA ALERT bezel available for order. S-24&HS-24 Product Horn Current Ratings Horn Decibel Levels Horn Current Ratings Minimum SPL Minimum SPL Regulated 24 VDC Horn Mode at 10 ft.,per at 10 ft.,per Max.Operating @ ANSI/UL 464 ANSI/UL 464 High Setting(mA) (HIGH) (LOW) Temp 3 2400 Hz 78 dBA 71*dBA 28 mA Temp 3 Mechanical 76 dBA 70*dBA 25 mA Temp 3 Chime 70*dBA 66*dBA 15 mA Continuous 2400 Hz 81 dBA 74*dBA 28 mA Continuous Mechanical 80 dBA 72*dBA 25 mA Continuous Chime 70*dBA 66*dBA 15 mA Whoop 82 dBA 69*dBA 56 mA NOTES: • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified]) power,see installation manual. • Potter does nto recommend usign a coded or pulsing signaling circuit with any of our strobe products. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service.These settings are acceptable only for private mode fire alarm use.Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 3 OF 4 06/13 S-24 & HS-24 (E) POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Architect&Engineering Specifications The audible and/or visible signal shall be Potter S-24 strobe and Potter HS-24 horn/strobe Series or approved equal and shall be listed by Underwriters Laboratories,Inc.per ANSI/UL 1971 and/or ANSI/UL 464.The notification appliance shall also be listed with Factory Mutual Listing Service(FM)and the California State Fire Marshal(CSFM). The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater at 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage.The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control Control Panel signal signal Panel Signal Signal g+ S+ S- H+ H- S+ S+ S- H+ H- s+ S+ S- H+ H- S+ S+ S- H+ H. Supervised Supervised 0 B 0 B Signal Circuit Signal Circuit \ + \ + END LINE END OF LINE RESISTOR RESISTOR \ + 7D END OF LINE RESISTOR NOTES: • All strobes are designed to flash as specified with continuous applied voltage.Strobes should not be used on coded or pulsing signaling circuits.However,use of the Potter AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe,horn,and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION,REFERENCE AVSM CONTROL MODULE DATA SHEET(8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS.AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 4 OF 4 06/13 GENTEX CORPORATION GOE OUTDOOR ENCLOSURE Applications A C C E S S O R I E S The Gentex GOE Outdoor Enclosure is ANSI/UL 464 listed for use in indoor and P A G E outdoor applications when used with the Gentex GEH Series horn and WGE Series strobe and horn/strobe. Standard Features • ANSI/UL 464 listed • Back box with side mount tabs • Made of clear Lexan°- providing maximum visibility and reliability • Unit Dimensions: 5.75" (14.61 cm) high x 4.75" (12.10 cm)wide x l •�,''- 4.18" (10.62 cm) deep • 3/4"conduit knockouts l'llll� • Reinforcement steel hardware --- R • Outdoor resistant gasket • Available in red or off-white GOE-R GOE-W GOELP OUTDOOR ENCLOSURE Applications The Gentex GOELP Low Profile Outdoor Enclosure that creates a surface mount look, is ANSI/UL 464 listed for use in indoor and outdoor applications when used with the Gentex GEH Series horn and WGE Series strobe and horn/strobe. Standard Features • ANSI/UL 464 listed • Back box with outdoor resistant seal for mounting to wall GOELP GOE • Made of clear Lexan°- providing maximum visibility and reliability • Unit Dimensions: 5.75" (14.61 cm) high x 4.75" (12.10 cm)wide x 3.25" (8.255 �+- cm) deep • 3/4"conduit knockouts • Reinforcement steel hardware • Outdoor resistant gasket • Available in red or off-white GOE AND GOELP NOTES: • Product does not meet ANSI/UL 1971 light distribution requirements • To allow for drainage, the seal on the bottom edge is not water tight GOELP-R GOELP-W GBLP OUTDOOR BACK BOX Applications f ►'� The Gentex GBLP Outdoor Back Box is constructed of durable plastic is ANSI/UL _ •, 464 listed for use indoor and outdoor applications when used with the WSSPK Series speaker and speaker/strobe. Gl Standard Features o' v • ANSI/UL 464 listed ,.. • 1/2"conduit knockouts with metal washer reinforcements i • Wiremold knockouts for 500, 700 Series and pendulum mount • Unit Dimensions: 6.20" (15.75 cm) square x 2.04" (5.18 cm) deep • Reinforcement steel hardware GBLP-R GBLP-W • Outdoor resistant gasket • Available in red or off-white ACCESSORIES PAGE GSB SURFACE BACK BOX Applications The Gentex GSB Surface Back Box is constructed of durable plastic and is fully compatible with the Commander' (GE)and Commander'(GE3) Series horns, strobes and horn/strobes. Standard Features • ANSI/UL listed for indoor use • 1/2" conduit knockouts with metal washer reinforcement • Wiremold knockouts for 500 and 700 Series • Unit Dimensions: 5.57" (14.15 cm) high x 4.55" (11.56 cm) wide x 1.47" (3.73 cm) deep • Screw heads hidden GSB-R • Available in red or off-white ALERT & AGENT BEZELS Applications The Gentex ALERT and AGENT bezels are constructed of durable plastic and is q fully compatible with the Commander (GE)and Commander' (GE3) Series horns, l strobes and horn/strobes. E Standard Features R T • Easy to install I • ALERT or AGENT wording on both sides of bezel • Available in red or off-white ALERT-W AGENT-R GCSB CEILING SURFACE BACK BOX Applications The Gentex GCSB Surface Back Box is constructed of durable plastic and is fully compatible with the Commander (GC) Series strobes and horn/strobes. Standard Features • ANSI/UL listed for indoor use • 1/2"conduit knockouts with metal washer reinforcement • Wiremold knockouts for 500, 700 Series and pendulum mount • Unit Dimensions: 6.2" (15.75 cm) round x 1.67" (4.24 cm) deep • Screw heads hidden • Available in red or off-white GCSB-R GCSB-W Important Notice: 551-0031-02 G E N T E X These materials have been prepared Gentex Corporation("Gentex")for informational purposes only,are necessarily summary,and arere not purported to servee as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these materials are complete and accurate,up-to-date,or in compliance with all relevant local,state and federal laws, CORPORATION regulations and rules. The materials do not address all legal considerations as there is inevitable Fire Protection Products Group•www.gentex.com uncertainty regarding interpretation of laws,regulations and rules and the application of such laws, regulations and rules to particular fact patterns. Each person's activities can differently affect the 10985 Chicago Drive •Zeeland, Michigan 49464 obligations that exist under applicable laws,regulations or rules. Therefore,these materials should be used only for informational purposes and should not be used as a substitute for seeking professional 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax legal advice. Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. 9 8 7 6 5 4 3 2 1 FIRE PROTECTION INC. DEVICE INSTALLATION REQUIREMENTSPARK 77 APARTMENTS Everett, Road VICINITY MAP 1 425-290-900730 GibsWA.98204 Gibson 600 xvAcwrrtr CEILING MOUNTED II � NOT PCRMITTED DAVID MOW SMOKEME 3'(YIN) HERE CEILING < m AUDIO/NSUAI I~I k VISUAL DEVCES ' PERMITTCD ERMNoTD , 12• 120904 x HERE HCRE MAX BUILDING 9 LEVEL III raec PERMITTED, D HERE DFAR INS PEE etvrtw B PIC1rISR PIG1rIFR 7wx NFPA NXH to.µ. �� FIRE ALARM di•IaN {AS•D ys.n 1/.7SN• OOOS05173 {.6•D YS N # � °u O ROY L CATS aa-nN WANT WAR WW PH MANUAL PH PULL -c--.;ce xJvi:nl' Q�QgOTECr�Oy • a�enE r,sr..:.r. JACK STATION iactunng Tech 48-YA% G N� y FlNISHED FLOOR A R L I N G T O N, WA �, CFPS #1473 CITY OF REDMO14D ° INSTALLATION NOTES raxloM°Boa °sa016-B-141 Fire Alarm Symbol Legend 204TH STREET N.E. 1) Prior to calling for inspection,the installer shall provide SYMBOL DESCRIPTION PART NUMBER M_FG QTY BACKBOXREQURREMENTS MOUNTING REQUIREMENTS documentation to the local AHJ stating that the system has been ® LCO REMOTE ANNUNCIATOR RA-6075 POTTER installed,tested,evaluated and confirmed to be in accordance with all > > C governing codes and the approved plans.The Fire Alarm System PS INTELLIGENT 10 AMP REMOTE POWER EXPANDER PSN-1000 POTTER 1 AREA OF WORK = w installer shall complete an NFPA72 Record of Completion(NFPA72 m w rs SPRINKLER TAMPER BY OTHERS BY OTHERS 10.18.2.1.1). The completed Record of Completion shall be provided to BUILDING 9 m q C Z the AHJ inspector at the time of inspection NFPA72 10.18.2.1.2.4. DM DUAL INPUT CONTACT MODULE DCM-4 POTTER 1 BBOX-4,Standard backbox,4 K Q U S P P ( ) BLDG.13 3 o c u7 u PULL STATION SINGLE ACTION P31.1T POTTER 1 BBOX-2,Standard backbox,2 48'AFF 2t]JFO 2) Instructions for the operating,testing and maintenance of the z'o ua N a system,along with record drawings otherwise referred to as (S) SMOKE,PHOTO,2-WIRE 2W-B SYSSENSOR 1 SBOX-2,Standard backbox.2 = 0 C w is LL ("as-built")and equipment specifications shall be provided at an BLDG.12 — °w m a N LF LED.LF,HORN/STROBE,MC,WH LLFHSW WHEELOCK 9 BBOX-4,Standard backbox,4 STAFF - > E: approved location(NFPA72 10.18.2.3). BLDG.11 m w w g z w 3 O w ® ° STROBE,EXCEDER 24V M-C,WALL,WHITE STW WHEELOCK 7 BBOX-2,Standard backbox,2 82-AFF BLDG.14 _ < Q u cL 3) All systems and devices shall be installed and tested per the 2� < �" o u r y�'11 R manufactures listing and the authority having jurisdiction(NFPA72 AMA HORN/STROBE,EXCEDER 24V M-C,WALL,WHITE HSW WHEELOCK 4 BBOX-2,Standard backbox.2 STAFF Z ________ BLDG.17 I REVISION RECORD 10.14.2.1).Label all device locations containing EOL resistors. Q _ -c Community_ ommunity _ d DATE I DESCRIPTION LF HORN LOW FREQUENCY,WH GHLFW GENTEX 16 BBOX-4,Standard backbox,4 BTAFF ^ r Building _ I -- - -- m 4)FACP&all Remote Power Supplies REQUIRE a DEDICATED 120VAC BLDG.15 I BLDG.9 j 20amp circuit.A notice placed in the FACP shall direct personnel to the MINI HORN,WH MHT-1224W POTTER 8 BBOX-2,Standard backbox.2 82-AFF location of the electrical panel that is supplying DEDICATED power to �NlW BLDG.10 ��II��II '�`-----`--'� ' the system(NFPA72,Section 10.5.5.1). The DEDICATED circuit breaker na° HORN/STROBE,2 WIRE,MC,RED,WALL HS-24WR POTTER 1 BBOX-2,Standard backbox,2 8TAFF 1 BLDG. @ that serves the fire alarm system shall be Labeled and Secured against FS WATERFLOW SWTICH BY OTHERS BY OTHERS 1 _ L SHEET LIST BLDG. tampering with a RED breaker lockout(NFPA72,Section 10.5.5.2). 16 1 - — FA 0.0 FA DETAILS FACP FRCP LOCATED IN BUILDING 17 P300 POTTER E — 1 _ OUTDOOR HIS WEATHERPROOF ENCLOSURE GOELP POTTER 1 d 'BLDG.5-. I,- BLDG.6 BLDG.7 __ FA 1.0 FIRE ALARM 5)This property will have one FACP located in the Community Building. I _ FA 2.0 RISER/CALCS Each residential building will have a Remote Power Supply and a —_______--__- __J I B Remote Fire Alarm Annunciator connected to the main FACP in the Community Building.The FACP will monitor each buildings fire B sprinkler system via SLC,the occupant notification devices in each r IL . .BLDG 1 --� --R-- --R - --- H- R-- the building will only activated when a fire alarm device from that - BLDG.2 J I BLDG..3 BLDG.4 specific building(waterflow,smoke detector,pull-station) is activated. _ - _ [ 6) Wall mounted strobes shall be placed 80"minimum to 96"maximum above floor level.(NFPA72 18.5.4.1 &2).Wall mounted strobes shall be SITE PHASING PLAN -� sized in accordance with(NFPA72 Table 18.5.4.3.1(a).Ceiling mounted SYSTEM OUTPUTS strobes shall be placed and sized in accordance with(NFPA72 Table Required Fire Safety Control 18.5.4.3.1(b). Control Unit Annunciation 7) When MORE than two notification appliances are visible at the same a°9 IF SCALE: 1/8"=1' time whether they are in the same room or adjacent space within the y C� Q° a h; DATE: 10/10/16 field of view,the flash of those strobes shall be synchronized(NFPA72, C N C; P g�"E�, Section 18.5.4.3.2(3)&(4). ,yA PROJECT NAME �g '�y CIRCUIT LINE TYPE Circuit Legend 8) Pull stations shall be placed between 42 and 48 inches above floor ';a °;moo'°°4 ° y.gym c .or f.E'ru level.Devices shall be red in color(ICC A117.1 309&NFPA 72 17.14.5) F c F y��o c'm=; Abbreviation Type Name Z w 9) Outdoor strobes required for approaching Emergency Vehicles to be located in the upper 25%of the building(at a serviceable height), ��� --- D U #18/4 FPLR SLC-SIGNAL LINE CRKT W w a?� 4"y `3" L� A #16/4 FPLR TWISTED PAIR NAC-NOTIFICATION CRKT and to be clearly visible from the emergency vehicle approach path. a d e F q B R #1814 FPLR SBUS of Z Q Z A J may= O 10 Fire Alarm circuits to be installed/secured/terminated in accordance Q~A° ` 1 ~ ~ A SYSTEM INPUTS A B C D E F G H I J Q J n with NEC,NFPA 72,IFC and Local AHJ requirements&standards. 1 Manual Fire Alarm Boxes ♦ ♦ ♦ ♦♦ 1 m r Z r- 2 Smoke Detectors ♦ ♦ - - ♦ - ♦♦ 2 3 Waterflow ♦ - - ♦ - - ♦♦♦♦ 3 Y N 11)The means of communication to the central stations for the fire Fire Alarm Device Numbering 4 Sprinkler Control Valve ♦ - ♦ 4 O alarm system is to be provided by a Potter UD-1000 DACT as per plan. 5 Fire Alarm AC Power Failure ♦ ♦ 5 (SLC)ADDRESSABLE DEVICES NOTIFICATION DEVICES Q N System requires 2 x POTS telephone lines,1 of these lines is required 6 Fire Alarm System Low Battery ♦ ♦ 6 a to be DEDICATED to the FACP.The FACP is located in building 17. 7 Open Circuit ♦ ♦ 7 CIRCUIT clRculr 8 Ground Fault ♦ ♦ 8 F �DEVICE ADDRESS DEVICE 11 12)All building linking conduit&wiring to be provided/installed by 9 Notification Appliance Circuit Short ♦ ♦ 9 / \ CANDELA o Remote Power Supply Trouble ♦ ♦ 10 slc•Alt \�I SHEET DESCRIPTION others. A B C D E F G H I J ` ) FIRE ALARM K I•sxr I I IacD OPERATIONAL MATRIX SMOKE DETECTOR SHOWN AS EXAMPLE s DETAILS SHEET NUMBER FA 0.0 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 FIRE PROTECTION INC. 1730 Gibson Road Everett,WA.98204 425-290-9600 DAVID MOW m L 120904 LEVEL III D -- - --- - — UNITB41 NFPAJ D scsmos — 000805173 III UNITB-10 I UNITB-8 j--- %1 UMTS42 9tasMs ` ROY L CATS H Q�Q9.,OTECI'ip2 r-- siGsoas 614 FPLR SIG 5 WO PS IN RISER ROOM w I moo 12 NFPA'yy 1 j _ ' CFPS L 1 I #1473 CITY OF REDMOND L I I — - - I _ i DAVID MOW RI I I STAIR/ '� I I etcxsa or as a De#16-B-141 ENT co H �011 A I ENTRY - ENTRY sKs.om I - ar�o,oT 2 - W_'S2N C 2 N Ll z�Fa O J � SO zow�l 510mm OmzO > Y wY mz.wti6K 3RD FLOOR 3o � a Q>>< 0= N ou ZH-+o.w REVISION RECORD DATE I DESCRIPTION OP164 THHN(SBUS)TO THE FACP LOCATED IN BUILDING 17 614 FPLR SIG 3 — 612 THHN SLC TO THE FAC O PS IN RISER ROOM - OCATED IN BUILDING 17 r10rT0 FPLR SIG 2 --- PS IN RISER ROOM I SHEET LIST FA 0.0 FA DETAILS I �+ zN,•aor FA 1.0 FIRE ALARM I I g S) J FA 2.0 RISER/CALCS UNIT:B-71L _UNIT B-2 UNIT B,3 I B I I siG,om UNIT B-1 I Type A siGaoo Type A I rs Fs UNIT B4 �— jl ,tOCD --- ZNZ•001 ZNt•001 �` I �H sw<.00s I UNIT BSTYPe A UNIT BS d ---- - UIT134 Type ASaao< r IG2,11 614 FPLR SIG -� - I I �. I 1111J I I 1 A I --— --O PS IN RISER ROOM A� T1II E«us SiNGG.3Dc.000 ' .. jII ssic—o�on— D rox_ mi l_yI STA—It1 1IYI'III-"_r_' SCA IIII A —ooH LE _ 1 , DATE 10/0/16 PROJECT NAME c s1D ue° O R/ STAIR/ STAIR s . sTAlw j ENTRY a I wD ENTRY G<W ENTRY ENTRY T sisl� z W Q W W SIG-5 1 110CD ' 3Kil006 . 4 SIGt•008 1,UGD I eO siGa att I i e N z Q O SIGt4W LF „OCp --- •. SIG,-0p5 A U I I LL _ A SiGI.005 I SIG9 Ot3 I I Q _ � z CD UP — V Y o Q UP 1ST FLOOR 2ND FLOOR a N N N SHEET DESCRIPTION FIRE ALARM SHEET NUMBER FA 1 .0 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 FIRE PROTECTION INC- 1730 Gibson Road Everett,WA.96204 425-290-9600 Battery Calculations for Panel:PS BUILDING 09 Part No:PSN-1000-INTELLIGENT 10AMP REMOTE POWER EXPANDER DAVID MOW Part No. oty. Description Standby Total Standby. Alarm Total Alarm Panel Equipment PSN-1000 MB 1 10 AMP POWER EXPANDER_MB 75.0000.4 75.0000mA 215.0000mA 215.0000mA �v Told Panel Stay 75.00WmA Total Papal Alarm 215.000OmN Peripheral Devices 2W-B 1 SMOKE,PHOTO,2-WIRE(Initialing) 0.010D.A 0.0100mA 6.5000mA 6. 120904, P31AT 1 PULL STATION SINGLE ACTION(Initiating) 0.000OMI 0.0000mA 0.0000mA O. I LEVEL III LLFHSW 9 LED,LF,HORWSTROBE,MC,WH(Notification) 0000OrM 0.0000mA 292.0000mA 2628.0000mA STW 7 STROBE,EXCEDER 24V MC,WALL,WHITE(Notification) D.000DMA O.000OMA 57.ODOOMA 399.0000.A HSWJ I HORN/STROSE,EXCEDER 24V,MC,WALL,WHITE(Notification) D.000OmA 0.0000.Al 102.0000mA 408.000DmA GHLFW 1 HORN LOW FREQUENCY,WH(Notification) 0000DMI 0.0000MA 99.4000mA 1590.4000mA MHT-1224W MINI HORN,WH(Notification) 0.0000.4 0.0000mA 22.0000mA 176.000DmA HS-24WR 11 HORN/STROBE,2 WIRE,MC,RED,WALL(Notifica8on) O.0000mA 0.000OmA 186.00M.A 186.00WmA D Total Peripheral Stby 0.0100mA Total Penph Alarm 53M.9000.A N F PA Total StandbyAmPs 75.0100mA TOW Alarm Ampsl 5608.9000.A 000805173 Standby time:24 Him lam ROYL CATS Alarm time:5 Min 0.467Ah P�QpOTECl/0y Battery requirement. 2.288Ah Compensation Factors-Standby:12 Alarm:12 Requirement with compensation: 2121Ah o ■ .A, ■ NFFW a b NFPA C and y5 Circuit Calculations Panel:PS Card:00 Circuit:SIG1 Circuit Calculations Panel:PS Card:00 Circuit:SIG2 Circuit Calculations Panel:PS Card:00 Circuit:SIG3 CFPS ClicuitName:SIGI Circu'itilame:SIG2 CirwitName:SIG3 #1473 Circuit Type:Notification Terminal Voltage:20.4V:DC Amperage:3.000OA Circult Type:Notification Terminal Voltage:204V:DC Amperage:3.0000A Circuit Type:Notification Terminal Voltage:20.4V.DC Amperage:3.0000A Cable:16/4C TWISTED FPLR#16 Cabls:16/4C TWISTED FPLR#16 Cable:16/4C TWISTED FPLR#16 Calculations based on Running Total Length. Calculations based on Running Total Length. Calculations based on Running Total Length, Design Criteria:Ambient temperature:167'F Max.operating voltage drop:15% Design Crilena:Ambient temperature:1676F Max.operating voltage drop:15% Design C item:Ambient temperature:167'F Max.operating voltage drop:15% •j'►��// Device Part No Appliance Desc Distance Current Voltage Voltage Drop Device Part No Appliance Desc Distance Current Voltage Voltage Drop Device Part No Appliance Desc Distance Current Voltage Voltage Drop CITY OF REDMOND PSN.lOD0 Panel - - - -20- PSN-1000 Panel 20.4 PSN-1 Panel 20AV DAVID MOW 001 HSW HORN/STROBE,EXCEDER 24V,MC,WALL,WHITE,30GD 39' 102.0000mA 19. (0.41� 001 LLFHB LED,LF,HORNISTROBE,MC,WH,110CD 4W 292.000OmA 19.812 (0.5873V) got S STROBE,EXCEDER 24V MC,WALL,WHITE,1SCD 107 5T 19310 0.0893V) 416-oe ea STW STROBE,EXCEDER 24V MC,WALL,WHITE,15CD Y-0 57.000OnIA 19.9641 (0.0194Vj 002 ST W STROBE,EXCEDER 24V MC,WALL,WHITE,15CD 16 57.00DOMA 19.6 (0T-V) 002 HSWHORNISTROBE,EXCEDER 24V MC,WALL,WHITE,30CD 21 102.0000mA 19.0981 (01126V) na#16-B-141cow 003 STW STROBE,EXCEDER 24V MC,WALL.WHITE,15CD 21'-0 57.0000MA 19. (0.1916V) DD3 STW STROBE,EXCEDER 24V M-C,WALL,WHITE,1SCD 1T-0 57.0000mA 19.5221V (O.15V) 003 STW STROBE,EXCEDER 24V MC,WALL,WHITE,15CD 117 57,000MM 18.9521 (0.146V) 004 LLFHSW LED,LF,HORN/STROBE,MC,WH,110CD 2-0 292.000OmA 19.7554 (0.0171V) 004 HSW HORN/STROBE,EXCEDER 24V,MC,WALL,WHITE,3DCD 21' 102.000OmA 19. (0.1735V) 004 LLFHSW LED,LF,HORWSTROBE,MC,WH,110CD 19' 292.000OmA 18. (0.1628V) LLFHSW LED,LF,HORNISTROBE,MC,WH,110CD 26'-0 292.000OmA 19. (0.1485V) 005 LLFHSW LED,LFi HORN/STROBE,MC,WH,110CD T 292.0000mA 1929M oo5 LLFHS w LED,LF,HORN/STROBE,MC,WH,110CD 4 2922-0000MA 18. (0.02281 O DDS LLFHSW LED,LF,HORN/STROBE,MC,WH,110CD Y-0 292.000D.A 19.8012 (OA0571/) D06 HSW HORNISTROBE,EXCEDER 24V,MC,WALL,WHITE,30CD 19-0 102.000OmA 1921 (0.0838V) 006 LLFHSW LED,LF,HORMSTROSE,MC,WH,IIDCD 14 292-OOOO.A 18.7265V (0.w > C 92'-0 1092.000OmA 007 LLFHSW LED,IF,HORN(STROBE,MC,WH,11000 R 292.0000mA 19.2002 (0.0137V) 176 1092.000OmA Taal Curren:1092.ODOUM 008 STW STROBE,EXCEDER 24V MC,WALL,WHITE,15CD 29' S7.000OmA 19.184_ (0.0162V) Taal Current:1052DOM (Taal VDnap Pement:3.92%) Tota Vaage Drop:0.7988V 160'-0 1251.000OmA (Total VDrop Percem:820%)Total Voltage Drop:1.6735V w m V m 1' Total Current:1251.000DMA Z (Taal VDrop Percerd:5.96%) Total Voltage Drop:1.216V 2#ad6 H D CS l2 0 2O Or W H Q QOJ� _Circuit Calculations Panel:PS Card:00 CircuitSIG4 Circuit Calculations Panel:PS Card:00 Circuit:SIG5 o m z W o Cimu"Mlame:SIG4 Cimud4ame:SIG5 m O LL H 0r dType:Notification Terminal Voltage:20.4V:DC Amperage:3.0000A Circuit Type:Notification Terminal V0lrege:20.4V:DC Amperage:3.0000A Cable:161 4C TWISTED FPLR#16 Cable:16/4C TWISTED FPLR#16 Calculations based on Running Total Length. Calculations based on Running Total Length. U COa Design Criteria'Ambient temperature:167°F Max.operating voltage drop:15% Design Cn na:Ambierntampereture:167'F Malcoperatingvogagedrop:15% Device Part No Appliance Desc Distance Current Voltage Volta a Drop Device Part No Appliance Desc Distance Current Voltage Voltage Drop REVISION RECORD PSN-1000 palm 20AV PSN-1000 Panel 204 DATE/DESCRIPTION OD1 GHLFW 74C RRLOW FREQUENCY,WH 44' 99.4000mA 19.8971V (0.5D2MI Doi GHLFW HORN LOW FREQUENCY,WH 66' 99.4000mA 19.8941V (0.5059V) 002MHT-1224W MINI HORN,WH V-0 22 19.8448 (0.0523V) 002 GHLFW HORN LOW FREQUENCY,WH 13' 99.400U.A 19.8071V (0.087V) 003 HS-24WR HORWSTROBE,2 WIRE,MC,RED,WALL,110CD 21' 186.000DmA 19.6298 (0.2151 003 MHT-1224W MINI HORN,WH X-O 22.0000.A 19.7899V (0.0172V) 004 GHLFW HORN LOW FREQUENCY,WH 11' 99.4000mA 19.5371 (0.092M 004 GHLFW HORN LOW FREQUENCY,WH 3fi' 99.4000 19.591 (0.19821,) GHLFW HORN LOW FREQUENCY,WH Y-0 99.4000mA 19.51 (0.0224V) HT-1224W MINI HORN,WH 3V 220000.A 19.4511 (0.1406V) MHT--1224W MINI HORN,WH 59 22.DWOmA 19.152 (0.3628V) 006 GHLFW HORN LOW FREQUENCY,WH 5-0 99.4000.A 19.42 (0.0216V) SHEET LIST 007 GHLFW HORN LOW FREQUENCY,WH 5' 99.4000.A 19.120 (0.0313V) 00 MHT-1224W MINI HORN,WH 37 22oO00mA 193191V (0-1104V) 008 GHLFW HORN LOW FREQUENCY,WH 3T 99.4000mA 18.9514 (0.1693V) 008 GHLFW HORN LOW FREQUENCY.WH 6-0 99.40OW 19.3034 (0.0157V) FA 0.0 FA DETAILS MHT 1224W MINI HORN,WH 447 22.000OmA 18.752 (0.1987V) 009GHLFW HORN LOW FREQUENCY,WH 3 r-O 99.4000 19.2 (0.0734V) 010 GHLFW HORN LOW FREQUENCY,WH 5' 99.4000mA 18.7322 (0.0205V) 010 GHLFW HORN LOW FREQUENCY,WH I V 99.4003mA 19.2134V (0.0166V) FA 1.0 FIRE ALARM 011 GHLFW HORN LAW FREQUENCY,WH 4TA 99.4000mA 18.600 (0.1315v) 011 MHT-1224W MINI HORN,WH 4' 22. 19.212 .0009V) FA 2.0 RISER/CALCS 01 GHLFW HORN LOW FREQUENCY,WH W 99.4000mA 18.592 (0.008" 244-0753. 01 GHLFW HORN LOW FREQUENCY,WH 26 99.4000mA 18.5623 (0.0297V) Total Current 783.8000mA 01 MHT-1224W MINI HORN,WH T 22. 18.5617V (O.00D810 (Total Vrrop PeMent:5.62%) Total Voltage Drab,1,1675V B 302 1168.6000mA Total Current:1168.6000mA (Total VDrep Percent9.01%) Total Voltage Drop:1.8383V SCALE: 1/8"=1' H LF LF LF LF FHl LF rHI LF LF DATE:1 10/10/16 gq g �g PROJECT NAME LF LF LF LF F-H1 LF LF H LF LF +p D F1 LF Uj Saco Uj 0) W I- C7 nao nao uao ucD � Ixo Q Z LF LF LF Jx Z O A y a < taco 3.D n 5 r Z +srn nao Waco Isco +sct ++ow h oo e- J TI LF b LF b o a < N Pt d 3000 BLDa 1+a0 11aD ItaD +5G0 rSCD 'vim LF LF LF Jx R � TsSHEET DESCRIPTION FA FIRE ALARM IN CALCS/RISER BUILDI SHEET NUMBER FA 2.0 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 FIRE PROTECTION INC. 1730 Gibson Road Everett 98204 425-290-90-9800 INSTALLATION NOTES ONDUIT WITH �g L D G. 1 � \ DAVID MOW 1 CONDUIT ROUTES ARE FOR REFERENCE, EXACT 6x THHN#16 1 x RED,1 x BLACK ROUTE TO BE DETERMINED BY THE ELECTRICIAN. 1 x BLUE,1 x WHITE \ BUILDING LINKING MUST BE DONE AS SHOWN FOR 1 xGREEN 1 xYELLOW \ A CLASS A LOOP AND PROJECT PHASING. 120904, \ \ / LEVEL III p 2)JUNCTION BOXES SHOWN ARE TO BE LOCATED IN THE FIRE SPRINKLER RISER ROOM OF EACH / \ \ BLDG 12 �� �� n BUILDING OR ON THE EXTERIOR WALL OF EACH . SPRINKLER RISER ROOM WITH A MINIMUM OF 16 J \\ \\ 4 f BLDG. 11 _ NFPA AWG WIRE AS SHOWN. JUNCTION BOX LOCATIONS 000sos173 SHOWN ARE BASED ON INDIVIDUAL BUILDING \ ROYL CATS ONDUIT WITH ONDUIT WITH Qaoreo> PLANS. i x THHN#16 x THHN#16 1 x RED 1 x BLACK 1 x RED,1 x BLACK ONDUIT WITH w 1 x BLUE,1 x WHITE 2 X THHN#16 L'1►J BLDG. 14 1XBLUE,IXWHITE 3) BUILDING LINKING CONDUITS/WIRING TO BE RUN 1 x GREEN,1 x YELLOW � 1x GREEN,1xYELLOW �' ,J 2xRED,2xBLAC b�JNFPAyyc TO A GUTTER IN THE ELECTRICAL/MECHANICAL `� \ 2x BLUE,2x WHIT E CFPS ROOM IN BUILDING 17 THE SITE FACP IS LOCATED 2x GREEN,2xYELLOW #1473 IN BUILDING 17). \\ \� / I I I I �& 4 ALL FIRE SPRINKLER RISER ROOMS REQUIRE 1 x ONDUIT WITH I I I CITY OF REbMOND DEDICATED 120VAC 20AMP CIRCUIT FOR EACH \ xTHHN#16 ONDUITWITH - C .,abnswo MO o BLDG. 17 xTHHN#16 1 x RED,1 z BLACK o.#16-B-141 w REMOTE POWER SUPPLY. 1 x DEDICATED 120VAC J- �� 1 x BLUE,1 x WHITE 1 x RED,1 x BLACK 20AMP CIRCUIT IS REQUIRED AT THE MAIN FACP IN \, 1 xGREEN,1 xYELLOW 1 x BLUE,1 x WHITE I 1 1 1 cn Community w 1 x GREEN,1 x YELLOW Q BUILDING 17 ( SEE FIRE ALARM DRAWINGS FOR oNDu1TWITH GEC ROOM II I T. d� w BUILDING FIRE ALARM DETAILS). -ONDUIT WITH xTHHN#16 Building �. _��� W x THHN#16 1 x RED,1 x BLACK G —m W N y w,oVm 'wx 1 x RED,1 x BLACK 1 x BLUE,1 x WHITE y � z#H a C 1 x BLUE,1 x WHITE t x GREEN,1 x YELLOW 1X GREEN,IX YELL OW oo� pS2 -BLD . 15� �� BLDG. 9 2 CI_ FilEXTERIOR OUTDOOR RATED JUNCTION BOX `� \ ® J ,,. _ __ N p o m a ONDUIT WITH __�� 1 a W p W a. x THHN#16 \ _ � , W 3o� a ` W 1 x RED,1 x BLACK N >a o a ELEC.GUTTER TO BE LOCATED IN ELEC RM OF BUILDING 17 \ J w La;; z a 1 x BLUE,1 x WHITE ����_ p O w N M w 1 x GREEN,1 x YELLOW \ g L D G. 10 ONDUIT TH REVISION RECORD \ WI x THHN M6 ^ DATE/DESCRIPTION 1 x RED,1 x BLACK {+� ONDUIT WITH 1 x BLUE,1 x WHITE x THHN ON WITH 1 x GREEN,1 x YEL I x LOW BLDG. 8 1 x RED, x BLACK x THHNHHN#16 r ` 1 x BLUE,1 x WHITE 1 x RED,1 x BLACKSHEET LIST r 1 x GREEN,1 x YELLOW 1 x BLUE,1 x WHITE 1 �.nnnnn�I I ' 1 x GREEN,1 x YELLOW Wuu BLDG. 16 N �� ONDUIT WITH o x THHN#16 B WI!® — 's—� f 1 x RED,1 x BLACK N J 1 x GREEN,1'xYETLLOW B _ BLDG. 5 ; J BLDG. 6, J BLDG. 7 a � N — ONDUIT WITH ONDUIT WITH x THHN#16 tu x THHN#16 1 x RED,1 x BLACK (� = 1 x RED,1 x BLACK _ t x BLUE 1 x WHITE \1 1 x BLUE,1 x WHITE 1 x GREEN,1 x YELLOW DATE: 10/10/16 ONDUITXTHH WITH 1 xGREEN 1 xYELLO e J� PROJECT NAME 2 X THHN#16 a 2 x RED,2 x BLACK 2 x BLUE,2 x WHITE 2 x GREEN,2 x YELLOW ~ LU I W Z Q BLDG. 1 ��BLDG. 2 BLDG. 3_ BLDG. 4 Q Z A Boa p� N ONDUIT WITH ONDUIT WITH d x THHN#16 x THHN#16 t x RED,1 x BLACK 1 x RED,1 x BLACK 1 x BLUE,1 x WHITE 1 x BLUE 1 x WHITE 1 x GREEN 1 xYELLOW 1 x GREEN,1 x YELLOW SHEET DESCRIPTION N FIRE ALARM SITE BUILDING 41 LINKING PLAN SITE BLDG LINKING PLAN E SHEET NUMBER 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 \ FIRE PROTECTION, INC. PO BOX 12642 MILL CREEK,WA 98082 14251 290-9600 OR 1-800-681-1125 FAX (4251353-4546 October 20,2016 City of ARLINGTON - PLAN REVIEW RE; FIRE ALARM SYSTEM Please find enclosed plans for a FIRE ALARM SYSTEM.The FACP will be located in building 17 ( lower floor of this building is the site community building) , all residential buildings will have their own individual fire alarm annunciator and remote power supply. All residential buildings sprinkler systems will be tied to and monitored by the FACP located in building 17 . The site electricians (Express Electric) are providing building linking conduit/wiring as shown on the included site building linking plan. The SLC and SBUS will be run in a Class A loop as shown. When a Waterflow, Smoke Detector or Pull-station is activated in a residential building, it will annunciate at the annunciator in that specific building and also at the FACP located in building 17 . Residential building occupant notification devices will only activate when an initiating device in that building is triggered, no other building' s occupant notification devices will active. The system has been designed per NFPA 72 , 2013 edition requirements as well as WAC, IBC, IFC 2012 , NEC current and your additional requirements . The building is fully-sprinkled. The system shall monitor by zone activation as well as separate trouble signals . Monitoring shall be provided via UL listed Central Station, The Alarm Center LACEY, WA. Audibility shall be in compliance with NFPA standards . Interior DB shall be 75 DB minimum throughout, (LOW FREQUECNY NOTIFICATION DEVICES TO BE INSTALLED IN RESIDENTAL SLEEPING AREAS . A full service and monitoring agreement is in force for the proper service and maintenance per NFPA requirements . A full pre-test and NFPA form shall be conducted and completed prior to calling the AHJ for acceptance testing. INSTALLATION COMPANY Fire Protection, Inc. 1730 Gibson Rd. Everett, WA 98204 WSCL# FIREPI*021ML UL CERT #608242-002 JOB SITE Park 77 Apartments *Building 9* 20201 77th Ave Ne Arlington , WA APPROVED UL MONITORING COMPANY Alarm Center, Inc. /FPI 4300 3rd Ave. SE Lacey, WA 800-429-0991 UL CERT #902799-02 CONTRACTUAL RESPONSIBLE PARTIES Installation; Monitoring; Service; Testing; Fire Protection, Inc. AMBIENT TEMPERATURES No area with alarm service equipment shall fall below 40 degrees, common areas shall be at 68 degrees per builder AMBIENT NOISE RANGE All areas serviced by the Fire Alarm Control and notification system will be as listed for per UBC listings, per builder. SEQUENCE OF OPERATIONS All Alarm and Trouble conditions shall enunciate at FACP as well as remote notify UL listed Central Station. Zones of alarm shall cause for all notification circuits to activate, send alarm zone to CS, re-dispatch to Fire and dispatch FPI runner service. Trouble and supervisory signals shall transmit to CS which will dispatch FPI runner service to site, (no notification circuits shall activate. ) On site emergency contact personnel shall be notified. Wet Waterflow ALARMS shall be retarded by a period of not more than 45 seconds . Low air shall activate at 25lbs, causing for a supervisory signal . A short on FACP smoke, Waterflow Switches, (wet and dry) and pull station shall cause a alarm. Shorts on PIV, tamper and Hi-low air zones shall cause a Supervisory condition. Opens on any zones shall cause for a trouble signal . Should you have any further questions, please feel free to contact me directly. David Mow VP of Operations/Designer NICET-3 #120904 CITY OF REDMOND D.O.R. #16-B-141 WA JOURNEYMAN LICENSE #MOW**DDE957M6 FACP FOR ALL BUILDINGS LOCATED IN BUILDING 17 @POTTER P 3 00 P/uS Fire Alarm Control Panel Features • 127 expandable to 381 Analog Addressable Points.Any combination of detectors/modules • 5 Amp Power Supply.Expandable to 315 amps • 2 NAC circuits rated at 3 amps maximum,expandable to 188. • 2 Input/Output(1/0)Circuits for system flexibility rated at 1 Amp . �• each _ • Built-in UL Listed IP Communicator • Built-in email event notification and report capability. • Optional Dual Line Digital Alarm Communicator • System wide synchronization of Potter/AMSECO,Gentex, Cooper/Wheelock,and System Sensor signals. • No twisted or shielded wiring required. • Cabinet will accommodate up to 18AH batteries.Panel will charge up to 55AH. • Capable of Class A or Class B wiring configurations • Built-in NFPA 72 compliant smoke detector sensitivity test • Dead-front cabinet design '' �. • 1000 Event History Buffer V` i NYC Fire Dept. Certificate of Approval Potter/Nohmi Protocol Features S735 7165-0328:0195 6156 • Less than 4 second polling time Product includes a 5 year warranty • LED's visible from 360' • Adjustable Smoke Detector Sensitivity • Adjustable Heat Detector Temperature annunciators,intelligent power supplies and other optional modules. • High Temperature Heat Detector as fixed temp The P-Link will support 31 accessories in any combination.The RA- Drift6075 is a 2 x 16 LCD annunciator.The RA-6500 offers a larger 4 x • Compensation 40 line LCD display that allows points and descriptions to be shown • Maintenance Alerts simultaneously.Intelligent remote power supplies repeat the P-Link data • Day/Night Mode and can be mounted 6,500 feet from reach other.P-Link devices such as the RLY-5 relay module,SPG-1000 serial parallel gateway and DRV-50 Description LED driver can be mounted anywhere in the chain of communication with a maximum of 31 of each P-Link devices.A total of two(2) The P300 is a mid-sized analog/addressable fire alarm control panel SLCE-127 Signaling Line Circuit Expanders(loop cards)may be with a total of 381 points.The points may be any combination of smoke installed in the P300 enclosure,in a remote enclosure such as the AE-8 sensors,heat detectors or modules.This panel has a 5 amp power supply or with a PSN-1000E remote intelligent power supply. that is distributed across two Notification Appliance Circuits(NACs) and two Input/Output(1/0)Circuits. The entire system,including the SLC,NACs and P-Link may be converted with a CA-6075 Class A module.The entire system is The NAC circuits are rated at a maximum of 3 Amps each and the 1/0 programmed using a Windows based computer software and requires circuits are rated for a maximum of 1 Amp each.All of the outputs may the use of a software programming software key. be configured for notification or auxiliary power.In addition,each NAC and Output can be programmed for strobe synchronization and utilizes The P300 can communicate to a monitoring station using the on board Quadrasync for strobe synchronization across circuits of various brands. Ethernet connection to an IP communicator or using optional UL listed The 1/0 may also be programmed for a dry contact input such as a water UD-1000 traditional two line alarm communicator.The UD-1000 flow switch or pull station. connects to the main board and has two phone line jacks provided. The IP communicator uses a RJ-45 connection and when connected The cabinet will hold two 12 volt,8 amp/hour batteries or two 12 volt, to the intemet may be programmed to E-mail system status,history 18 amp/hour batteries.The system when fully loaded will charge 55 reports,reminders and the configuration file.The panel may be updated amp/hour batteries.Anything larger than 18 amp/hour will require an remotely using the LTD-1000.If the Ethernet connection is needed external battery cabinet the SSU-00050. remotely,the FCB-1000 fire communication bridge may be installed to The panel has the Potter P-Link connection for expansion with remote allow the Ethernet connection to be installed in a rack. Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • wwpottersignal.com P'�O�IUsJ w. #8830035-REV A PAGE 1 OF 4 08/12 (E) POTT ER P 3 00 Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 381 addressable devices or modules in any combination.The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PSA Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PSHA Combination Analog Photo Electric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135'Fahrenheit heat detector FHA Analog Fixed Temperature Heat Detector that is selectable from 135'F to 185°F RHA Analog Rate or Rise Heat Detector that has a fixed temperature selection from 135°F and 174°F and also will alarm if the temperature increase 12-15°F in one minute DDA Addressable Duct Smoke Detector AB-6 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors AB-4 4"round base that may be mounted to an electrical box and wired for connection to the above sensors AIB Isolater base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop ARB Addressable Relay Base that contains two relays controlled by the SLC.One relay is rated at 8 amps at 240 VAC/30VDC and the other is rated at 2 amps 240 VAC/30 VDC ASB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call. Modules Device Description MCM Miniature Contact Module provides a small foot print contact module for mounting inside an enclosure. APS-SA Single Action Addressable Pull Station APS-DA Dual Action Addressable Pull Station SCM-4 Single Contact Module is a standard contact module with an LED that mounts into a 4"square electrical box. DCM-4 Dual Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. TRM-4 Twin Relay Module provides two form C relays that simultaneously active when the module is triggered by the control panel. Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC. MOM-4 Monitored Output Module is a power switching module that monitors the circuit that is controlled by the control panel. CIZM-4 Conventional Input Zone Module is used to connect conventional smoke detectors to the system that receive their power from the module.This module is like a conventional zone on the SLC. SCI Short Circuit Isolater interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • www.pottersignal.com P"�O�A'SP v #8830035-REV A PAGE 2 OF 4 08/12 (E) POTT ER P 3 00 Fire Alarm Control Panel SLC Features RA-6075—2 x 16 LCD annunciator with a key pad in a locked metal enclosure. The Potter/Nohmi protocol is a digital protocol with a proven design for reliability and noise immunity.The system does not require special RA-6500—4 x 40 LCD annunciator with a key pad in a locked metal cable or conductors for connection of the Signaling Line Circuit as enclosure long as the cable is compliant with NFPA 70 and NFPA 72.The system LED-16—16 LED annunciator with common indicators in a locked allows for Class A or Class B installations as well as"T-Taps." metal enclosure The total polling time for the protocol is about four(4)seconds which PSN-1000(E)—10 amp,remote intelligent power supply with 6 NACs, allows two polling cycles in the ANSUUL 864 requirement of alarms 2 I/Os and a P-Link repeater reporting in less than ten seconds.Each loop is capable of 127 points with the exception of the P100 and P200. CA-6075—Class A convertor that converts the SLC,NACs and P-Link connection Sensor Features UD-1000—UL listed,Dual line telephone alarm communicator The sensors through the fire alarm control panel provide a real DRV-50—LED driver expander,used to connect up to 50 LEDs in a time status as to the condition of the system.The smoke detector graphic display sensitivity,heat detector temperature level and drift compensation FCB-1000—Fire communication bridge,provides remote mounting of as all programmable options.The system also allows for a day/night the Ethernet connection mode where the panel automatically adjusts the sensitivity depending on the time of day.To assist in the reduction of false alarms,the smoke FIB-1000—Fiber interface module,used to extend P-Link to multi- detectors also have a maintenance warning that sends a trouble signal mode fiber(2 required) when a detector is dirty to the point that it can no longer maintain the RLy--5—Relay module,provides 5 form C relay contacts rated at 3.0 programmed sensitivity. amps 24VDC/125AC User Interface SPG-1000—Serial parallel gateway,allows for the connection to a serial or parallel printer The fire alarm control panel has a 4 x 40 LCD display to provide information to the system status.The keypad has navigation keys The FIB-1000,FCB-1000 and the SPG-1000 maybe installed in the t stacker bracket or ordered with the optional rack mount enclosure.o allow manipulation of the Menu on board the panel.The panel is shipped standard with the following LEDs: AE-8—Eight card expansion cabinet • AC Power—Green AE-14—Fourteen card expansion cabinet • Alarm—Red Ethernet/I.P. Connection • Earth Fault—Amber The P300 is shipped standard with an Ethernet connection.This • Supervisory-Amber connection is the programming port and may be connected to a building • Silenced-Amber Wide Area Network(WAN)or Local Area Network(LAN).Once connected to the Internet,the panel may be selectively programmed to • Trouble-Amber e-mail alarm conditions,trouble conditions,supervisory conditions,test, The common buttons include a Silence,Reset,Acknowledge and Drill. Event History and detector status.An e-mail may be sent to the panel All of the buttons are accessible once the locked door is opened. and the panel will e-mail the event history,detector status,configuration file or server status to an authorized E-mail account.In addition, P-Link reminders may be set to send an e-mail for service,testing or other The P300 has a proprietary communication protocol that communicates conditions. through a RS-485 connection to field devices.Up to thirty-one In addition,the Ethernet connection is UL listed as an IP communicator. (31)devices may be connected to a single P-Link connection.The The IP communicator is listed to report to the UL listed Sur-Gard III P-Link includes the communication terminals and regulated 24 VDC IP receiver.The IP communicator replaces the traditional less reliable connection for the field devices.The field devices may be any of the alarm communicator transmitter that utilized telephone lines.The IP following: communicator is an active method of connection and communication to SLCE-127-Analog/Addressable loop expansion module(maximum of 2 the monitoring station. per P300) Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • wwpottersignal.com P'��PlusZ* w. #8830035-REV A PAGE 3 OF 4 08/12 (E) POTT ER P 3 00 Fire Alarm Control Panel Specifications 18.91" 17.60" Electrical Specs:AC Mains O O TOP o 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @ 240 VAC 50/60 HZ 4.41" 3.75" DEPTH Battery p 0 130 mA Standby 220mA Alarm b • 5 Amps power for NACs,I/O and P-Link • 3 Amps per NAC,regulated a • 1 Amp per I/O circuit,regulated �e c7 O • Battery Charger range 8-55 Ah • Battery Charger voltage 27.3 VDC • P-Link maximum current of 1 Amp • Panel holds(2)8AH or(2) 18AH batteries LEFT SIDE RIGHT SIDE Cabinet • 16 gauge cold rolled steel with removable BOTTOM ` locked door • Dimensions—18 15/16"W x 27 5/16"H x 4 7/16"D • Dead front to cover all electronics • Lexan viewing window Temperature and Humidity This fire alarm control is listed and approved for operation in an indoor application with temperature range fluctuations of 32'to 120'(0°C to 49°C) with a maximum humidity of 93%non-condensing.The ideal temperature is 77°F +/- 10°F(25°C+/-5°C). Standards The P300 series fire alarm control panel complies with the following standards and codes. • NFPA 13,70 and 72 • ANSI/UL 864 0 Local(L),Remote Station(RS),Central Station(CS),Propriety(PPU),Auxiliary(AUX) 0 Type of Service:Automatic(A),Manual(M),Water flow(WF)Sprinkler Supervisory(SS) 0 Type of Signaling:Digital Alarm Communicator(DAC),March Time(March),Non Coded(NC),Reverse Polarity(Rev Pol),Other Technologies(OT) • IBC 2000,2003,2006,2009,2012 Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • wwpottersignal.com P'h�T PUF'J w. #8830035-REV A PAGE 4 OF 4 08/12 POTTER RA-6075 The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Features Standby Current 20 mA Alarm Current 25 mA Operating Temperature 0°C-49°C(32°F-120°F) 10%-93% @ 30°C(86°F)non-condensing 0 © humidity Maximum Wire Length 6500 FT ® © Maximum Annunciators 31 - Dimensions(WxHxD) 8"x 6-1/4"x 1-5/8"(Cabinet) Wire Gauge 14 AWG-22 AWG Display 2 lines x 16 characters Product includes 5 year warranty U� LISTED S2930 7165-0328:0195 Description Installation The RA-6075 is a LCD remote annunciator for the PFC-6075 and The RA-6075 is connected to the PFC-6075 using a four wire RS-485 PFC-6030 addressable fire control panel.The RA-6075 communicates connection.The connection is power limited and supervised.Up to using a RS-485 connection to the main panel providing common thirty-one(31)RA-6075 LCD annunciators can be connected using indication of Alarms,Supervisory,Trouble and other system status and Class B or Class A wiring.Class A wiring requires an optional Class A control functions. Expander. The RA-6075 features a 32 character, 16x2 LCD display with LED's for Power,Alarm,Supervisory,Trouble,and Silenced conditions. , It can be mounted on a single gang electrical box or a four square electrical box.The annunciator is enclosed in a sheet metal enclosure Instal!inac!cord!anc!e with compatib7fir,alarm panel. and has a Potter lock securing the keypad. Figure 1:RA-6075 Class B Wiring Example Figure 2:RA-6075 Class A Wiring Example To the next annunciator 4CA-60775 + m + a P-LINK + a + A B + + + + Panel + + + + + + Panel + + Connection Remote -LIN + Annunciator Connection + Remote -LIN< Annunciator m Q m Oa O a + Q O Remote O Remote Annunciator Annunciator Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#5406077-REV B-1 PAGE 1 OF 2 9/11 (E) POTTER RA-6075 The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Address Settings The RA-6075 address is set by dip switch S 1 located on the back of the RA-6075.The address must be set in the range of 1 to 31 to be recognized by the control panel. Figure 3:RA-6075 Class A(back panel view) O ❑ 0 0 OWWWW .-9. O 0 © A on ® 9 ® + Al O o Dip Switch Settings Refer to the table below for dip switch settings per Annunciator Address. Annunciator Dip Switch Settings Annunciator Dip Switch Settings Address SW-1 SW-2 SW-3 SW-4 SW-5 Address SW-1 SW-2 SW-3 SW-4 SW-5 1 On Off Off Off Off 17 On Off Off Off On 2 Off On Off Off Off 18 Off On Off Off On 3 On On Off Off Off 19 On On Off Off On 4 Off Off On Off Off 20 Off Off On Off On 5 On Off On Off Off 21 On Off On Off On 6 Off On On Off Off 22 Off On On Off On 7 On On On Off Off 23 On On On Off On 8 Off Off Off On Off 24 Off Off Off On On 9 On Off Off On Off 25 On Off Off On On 10 Off On Off On Off 26 Off On Off On On 11 On On Off On Off 27 On On Off On On 12 Off Off On On Off 28 Off Off On On On 13 On Off On On Off 29 On Off On On On 14 Off On On On Off 30 Off On On On On 15 On On On On Off 31 On On On On On 16 Off Off Off Off On PRINTED IN USA MFG.#5406077-REV 13-1 PAGE 2 OF 2 9/11 CPOTTER PSN-1000(E) The Symbol of Protection POWER EXPANDER Features 10 Amp Power Supply • 3 Amps,regulated per NAC • 6 NACs Class B or 3 NACs Class A • 2 dry contact inputs • Fully programmable and monitored through control panel _ I Isolated P-Link repeater connection,Class A or B • Up to 31 power supplies per control panel with system wide sync • Quadrasync feature synchronizes strobes from Potter/AMSECO, Gentex,Cooper-Wheelock and System Sensor. ®RPOTTFR PSN-1000 Compatible with all Potter PFC-6000 series fire alarm control panels. Ines➢pool of Frowpon P.—Supply --. Electrical Specs • 120/240 VAC Input at 50/60 HZ • 5.1 Amps/3.0 Amps max draw • Standby Current 60 mA • Alarm Current 200 mA U` S2930 7165-0328: 0195 Product includes a 5 year warranty Description The PSN-1000 series is a UL listed intelligent 10 amp notification power supply and P-Link(RS-485)repeater.The power supply connects to the P-Link bus from the control panel and is operated and supervised from the panel.The power supply may be installed 6,500 feet from the control panel.The PSN-1000 then repeats the P-Link communication for another 6,500 feet. The power supply has six(6)Class B or three(3)Class A power outputs.Each output is regulated and power limited with a 3 Amp maximum rating.In addition,the PSN-1000 has two(2)programmable dry contact inputs.The dry contact inputs are Class B,supervised inputs. The power supply operates on either 120 or 220 VAC power and has a regulated 24 VDC output.In addition,the panel can charge up to 55 AH batteries and will house 18 AH batteries.The cabinet is constructed out of 18 gauge cold rolled steel with a durable red powder coat finish.A standard Potter key lock is provided for securing the door.Electrical conduit knockouts are provided on the sides and top providing installers with multiple options for installing conduits and providing proper power separations. The PSN-1000 is a self contained intelligent power supply/P-Link repeater complete with cabinet.The PSN-1000E is the intelligent power supply/P-Link repeater with additional cabinet room for the exclusive Stacker Bracket for SLCE-127 loop expanders.Both cabinets include space for 18 AH batteries. The power supplies are programmed and controlled through the main control panel P-Link bus.The panel displays any troubles or off normal conditions of the power supply and the events are stored in the panel history buffer. Each output can be independently configured to provide one of four synchronization patterns,constant power,ANSI temporal Code 3 or Door Holder power.The panel can be configured to synchronize Potter/AMSECO®,Gentex®,Cooper Wheelock®and System Sensor®. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830032-REV B PAGE 1 OF 2 09/14 (E) POTTER PSN-1000(E) The Symbol of Protection POWER EXPANDER 18.91" 17.60" 4 0 0 TOP w 0 4.41" 3.75" DEPTH O O 0 0 0 N O O O 0 LEFT SIDE RIGHT SIDE BOTTOM Dimensional drawings showing the cabinet in all three planes. Knock out locations. PRINTED IN USA MFG.#8830032-REV B PAGE 2 OF 2 09/14 4, �� SYSTEM � SENSOR t 41, Photoelectric Smoke Detectors System Sensor i3-series smoke detectors represent significant advancement in conventional detection. 3 The i3 family is founded on three principles:installation TM ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its •Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included with heads).The large wire entry port and in-line terminals provide Large wire entry port ample room for neatly routing the wiring inside the base.The base •In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single-gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,i3 boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock'action. •Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features •Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and •Built-in remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize nuisance alarms.2-wire i3 detectors can generate a remote LED- indicated maintenance and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 •Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i3 •Wide-angle,dual-color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof i3 Loop testing via EZ Walk feature detectors in terms of percent-per-foot obscuration. • •Built-in test switch Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on 2-wire P detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. T istin s M MEA MSFMTPROVED approved approved cC I,us I W6 7272-1653:152 290-01-_ 3C93? (-L3)Smoke Detector Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 1357 (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5 V Maximum:35 V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 NA maximum average;4-wire:50 NA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V Peak Standby Current 2-wire:100 uA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 1207(0°C to 49°C);2WT-B and 4WT-B:327 to 1007(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 1357(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:417(5°C) Sensitivity 2.50/o/ft nominal Input Terminals 14 to 22 AWG Mounting 3'/2-inch octagonal back box 4-inch octagonal back box Single-gang back box flinch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12 V,23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V,23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter f_ SY TE� m2cha system Sensor. �/ 3825 Ohio Avenue•St.Charles, L 60174 Product specifications subjec[to009 System Sensotice.Vsit rystemsensoccom for SENSOR Phone:800-SENSOR2•Fax:630-377-6495 urrentproductinformat5-03180i7-6/09 latest version okhis data sheet. A06-0318-007.6/09•#2169 PULL STATION SERIES (E) POTTER DIE-CAST METAL The Symbol of Protection MANUAL PULL STATIONS • UL and cUL Listed,FM Approved,CSFM Listed,MEA ' Approved,ADA Compliant • Single or Dual Action • Terminal connectors PULL UOWN Big . 10 Amp Snap Action Switch Gold plated SPST contacts Optional auxiliary contacts Mounts on standard single gangbox • Surface backboxes available • High-gloss red enamel finish • Glass breakrod DUs FMo �5 Made in the U.S.A. LISTED Description Engineering Specifications The Potter Pull Station Series offers a complete line of die-cast pull The contractor shall furnish and install the Potter series of pull stations for a variety of applications focusing mainly on fire alarm stations as indicated.The pull station shall be die cast construction systems.The pull stations are available in single or dual action with a"T"type pull handle that is ADA compliant.Single action pull models.All of the pull stations have a 10-amp snap action switch and stations shall be a P32-lT.Dual action pull stations shall be the Potter a dedicated terminal block for the ease of wire connections.All of P32-1T-LP.Any manual pull station installed in an outdoor or wet the metal is completely coated to inhibit corrosion and provide for a location shall be a RMS-IT--WP weather proof unit.The contact shall uniform and quality finish. be a single pole,single throw switch rated at 1 amp 30V DC/125V The standard models have a hex key reset,however a key reset is also AC.The device shall have a terminal block for ease of wiring.Once available.The models are available with shallow and deep surface activated,the pull station shall be reset by opening the front cover. mount back boxes and as a weatherproof version. Opening of the cover in a normal state shall initiate an alarm. Operation Specifications The Potter single action series of pull stations operate by pulling Switch Rating: 1 Amp @ 30 VDC the white operating handle straight down and the handle will lock 10 Amps @ 125 VAC into place.The dual action stations require the lifting of the front Pull Station Dimensions: 4-3/4"H x 3-1/4"W x 7/8"D cover and then pulling the white operating handle straight down.The Color:Red with raised white letters,white pull bar with raised red letters stations are reset by opening the front and placing the handle in the For special application manual stations see bulletin#8910014. normal position. For explosion proof manual stations see bulletin#8880014. Ordering Information Type Model Number Stock Number Contact Type P32-1T 1000447 SPST RMS-2T 1000477 DPST Single Action RMS-6T 1000478 DPDT RMS-1 T-KL 1000451 SPST RMS-IT-KO 1000450 SPST,key operated,no pull Weather Proof RMS-1 T-WP 1000401 Dual Action P32-1 T-LP 1000476 SPST Weather Proof Dual Action RMS-IT-WP-LP 1000403 Accessories Notes Dual Action RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1000470 Replacement glass rods(10 per pkg) Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8900097-REV L PAGE 1 OF 1 9/10 P POTT ERS A ka-"Wl' DCM-4 ® The Symbol of Protection Dual Contact Module Features • Single module with dual contact monitoring inputs • Two(2)Class B or one(1)Class A monitoring inputs • SLC Class A(Style 6,7)&Class B(Style4) • Mounts in a standard 4"or double gang box s- S. • Wiring terminals accessible when mounted in box ©E�►•■-�+•�.+o • All wiring terminals accept 22 to 14 AWG li wsiar • Product includes a 5 year warranty ee _.. NOTE: This addressable module does not support 2-wire smoke f zz1,1" zi ;, ci detectors. Stock Number: 1430822 LISTED �zw� S2930 7165-0328:0196 Application Technical Specifications The DCM-4 is compatible with Potter's PFC-6000 series and PFC- Operating Voltage 22.0-24.OV 8500 addressable fire alarm control panels.The DCM-4 is an interface Max SLC Standby Current 325 µA module used to monitor dry contact devices such as sprinkler water Aux Power Required 1mA flow,valve tamper switches,or conventional pull stations.The module is capable of monitoring two separate Class B or one Class A circuits. Max Wiring Resistance of IDC I 100 S2 Max Wiring Cpacitance of IDC 1 µF EOL Resistor 5.lK S2 Description Operating Tempurature Range 32 to 120°F(0 to 49°C) The DCM-4 uses two (2) consecutive SLC loop addresses when Operating Humidity Range 0 to 93%(non-condensing) monitoring two(2)Class B circuits or one(1)address when monitoring 127 units(Class A)or 63 units a single class A(Style D)circuit.The module mounts on either a 4" Max no.of Module Per Loop (Class B) square or double gang box.The module is capable of monitoring two (2)separate class B circuits making it ideal for monitoring sprinkler Dimensions 4.17"(106mm)L X 4.17" waterflow and valve tamper switches when they are located in the same (106mm)W X 1.14"(29mm)D proximity.The DCM-4 includes one red LED to indicate the modules Standard 4"Square or status.In normal condition,the LED flashes when the device is being Mounting Options Double Gang Box polled by the control panel.When a contact is activated,the LED will Shipping Weight 0.6 lbs light continuously and in case of an open circuit,the LED will turn off. Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com 8830008-REV B • 7/14 PAGE 1 OF 2 P POTT ERS OHM/® DCM-4 ® The Symbol of Protection Dual Contact Module Setting the Address Each addressable module, smoke sensor,heat detector and combination sensor/detector must be assigned an address prior to installing the device.The address is set using either the hand held device programmer or the addressing feature on the PFC 6000/PFC 8500 Series control panels.When the DCM- 4 is used to monitor two individual Class B circuits a single device address is assigned,with the second address number assigned automatically by the module assuming the next consecutive address.For example,if the first address number is assigned as"2",the second address number will automatically be assigned as SLC device address"3". Before connecting a device to the SLC loop,take the following precautions to prevent potential damage to the panel or device verify the following: 1.Power to the device is removed 2.Field wiring is correctly installed. 3.Field wiring has no open or short circuits. Installation Using Compatible Electrical Box O e ° ° o e Wiring Diagrams DCM-4 With One Class ACircuit NOl FROM FACP OR C 1 PREVIOUS MODULE S+ ZI S- NO2 TO THE NEXT MODULE F 1 C2 SELECT STYLE D 0000 LED Q Z2 NOTE:END-OF-LINE RESISTOR IS NOT REQUIRED DCM-4 With Two Class B Circuits NOl FROM FACP OR C 1 PREVIOUS MODULE S+ Zl "OHM1/2W S- NO2 TO THE NEXT MODULE ppH1pC2 �000 LED O Z2 SELECT STYLE B 5.1K OHM 1/2W Potter Electric Signal Company,LLC St. Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 www.pottersignal.com :so 9001:2008 1 DESIGNING,MANUFACTURING, 8 DISTRIBUTING QUALITY SYSTEMS 8830008-REV B • 7/14 PAGE 2 OF 2 GENTEX CORPORATION Low Frequency Audible Signal GHLF Applications 24 V D C The GHLF is a high quality, low profile, low frequency audible appliance that offers a dependable audible alarm with a low current draw. The GHLF is ideal for any S E R I E S occupancy that requires notification appliances. The GHLF horn offers a 520 Hz square wave,temporal 3 tone. A jumper selection is available for normal or loud decibel tone. A temporal 4 pattern is available when used with the Gentex GTSM Synchronization Control Module. The GHLF is shipped with a standard 4" metal mounting plate which incorporates the popular Super-Slide°feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The GHLF also features the patented Checkmate°- Instant Voltage Verification feature which allows the installer to check the voltage drop and match it to the blueprint. The GHLF horn is listed to ANSI/UL 464 and CAN/ULC S525, is listed for use with fire Product Listings protective systems and is warranted for three years from date of purchase. SIGNALING Standard Features � • Nominal voltage 24 VDC • Input terminals accept 12 to 18 AWG C&uS :U0= O Unit Dimensions:6-1/8"(15.55 cm)high x • Produces a 520Hz square wave,temporal 3 LISTED 5-1/2"(13.97 cm)wide x 1-5/8"(4.13 cm) tone deep • Jumper selection for normal or loud dBA • ANSI/UL 464 Listed • Super-Slide®Bracket-Ease of Supervision • Temporal 4 pattern available when used • CAN/ULC S525 Listed Testing with Gentex GTSM Synchronization Module • CSFM: Pending • Checkmate°-Instant Voltage Verification • Temporal 4 520Hz measured per Product Compliance • Synchronize horn with Gentex GTSM ANSI/UL 2075 • NFPA 72 Synchronization Control Module • Tamperproof re-entrant style grill and • IBC/IFC/IRC • Prewire entire system,install mounting locking screw(optional use) • Quality Management System bracket,then install signals • Faceplate available in red or off-white is certified to:ISO 9001:2008 Model Number Part Number Nominal Voltage Model Designations: �i •j ' = R=Red Faceplate MEMBER •� GHLFW 904-0530-002 24 VDC W=White Faceplate ASSEMBLED IN GHLFR 904-0531-002 24 VDC All units are plain(no lettering) THE USA Horn Decibel Levels: 24VDC Nominal Horn Horn Current Ratings Reverberant Room Current Ratings(mA) Over Input Voltage Range of 16-33V(mA) Minimum SPL Minimum SPL 24VDC 24VDC 24VFWR 24VFWR Regulated Regulated Regulated Regulated at 10Ft.Per at 10Ft.Per Operating Operating Operating Operating 24VDC Max. 24VDC Max. 24VFWR Max. 24VFWR Max. Horn Mode Operating Operating Operating Operating ANSI/UL 464 ANSI/UL 464 Current Current Current Current Current Current Current Current (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) Temporal 3 520 Hz I 77.8 dBA 1 79.8 dBA 72.1 mA 120.1 mA 104.6 mA 158.4 mA 99.4 mA 155.8 mA 152.1 mA 213.5 mA Temporal 4 520 Hz*1 81.5 dBA 1 83.4 dBA 75.9 mA 116.0 mA 108.1 mA 182.0 mA 100.1 mA 157.2 mA 163.1 mA 235.2 mA O Temporal 4 520 Hz measured per ANSI/UL 2075 NOTES: • Operating temperature:32 to 120 F(0 to 49 C).The GHLF is not listed for outdoor use. • For nominal and peak current across ANSUUL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. RMS current ratings are per ANSUUL average RMS method. ANSUUL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units). For unfiltered FWR ratings,see installation manual. GHLF 24 VDC S E R I E NOTES: UL Listed • THIS APPLIANCE IS NOT RECOMMENDED FOR USE ON CODED OR Control Signal Signal PULSING SIGNALING CIRCUITS Panel S+ s- s- H+ H- S+ s+ s- H+ H- • THE FOUR PULSE TEMPORAL PATTERN(TEMPORAL 4)CAN ONLY BE Supervised 0 0 0 0 OBTAINED ON THIS PRODUCT WHEN USED IN CONJUNCTION WITH Signal Circuit THE GENTEX GTSM SYNCHRONIZATION MODULE 1 + ENO LINE • SEE GTSM CONTROL MODULE MANUAL(550-0632,MANUAL ISSUE RESISTOR DATE(02-01-15)FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. S GTSM MANUAL CAN BE OBTAINED AT WWW.GENTEX.COM/FIRE OR CALL GENTEX CORPORATION AT 1-800-436-8391. DOIMIW x o Lt LOCKING 0 0 o SCREW 0 " (optional) Cho H+ logo RED WIRES �- H! Q BLACK WIRES 6- � O o H- U a O o 00 NORMAL-LOUD o c �`f/ DECIBEL JUMPER. 0 0 FOR LOUD DECIBEL CEED INSTALL JUMPER. SLIDE ONTO BRACK Gentex Checkmate® Gentex Super-Slide® LOCKING Instant Voltage Verification: Mounting Bracket: SCREW It is often necessary to confirm the voltage drop Allows the installer to pre wire the system, (optional) along a line of devices.The access holes are test for system supervision,remove the provided in the back of the terminal block to signal head until occupancy,switch out allow the voltage to be measured directly without Gentex signals without changing removing the device.Typically this would be done mounting brackets and has locking edge at the end of the line to confirm design criteria. connector for snap-in-place installation. Most measurements will be taken using the S+ and S-locations although access is provided to other locations. NOTICE:CARE SHOULD BE TAKEN TO NOT qM SHORT THE TEST PROBES. Architect & Engineering Specifications The alarm horns shall be Gentex model GHLF.The appliance shall be listed with Underwriters Laboratories(ANSI/UL)for use with fire protective signaling systems (ANSI/UL 464) and with CAN/ULC S525 with intended use in fire alarm systems. The GHLF will produce a peak sound output of 88.3 dBA as measured in an anechoic chamber. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power at 24 VDC. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton Important Notice: GHLF-01 GENTEX These materials have been prepared Gentex Corporation Gentex')for informational purposes only,are O necessarily summary,and are not purported to serve as legall advice and should not used s such. Gentex makes no representations and warranties,express or implied,that these materials are complete and CORPORATION accurate,up-to-date,or in compliance with all relevant local,state and federal laws,regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to Fire Protection Products Group•www.gentex.com particular fact patterns.Each persons activities can differently affect the obligations that exist under applicable laws,regulations or rules.Therefore,these materials should be used only for informational 10985 Chicago Drive •Zeeland, Michigan 49464 purposes and should not be used as a substitute for seeking professional legal advice.Gentex will not be 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. CPOTTER MHT 1224 SERIES The Symbol of Protection LOW CURRENT MINI-HORN Features • Single unit is capable of 12 or 24 VDC determined by the input I voltage - Y I I IEI I Unit Dimensions:4.48"(11.38cm)high x 2.84"(7.21 cm)wide x F I 0.5"(1.27 cm)deep Jumper selectable temporal 3 or continuous tone I I I i Horn frequency is 3100Hz I I I I Terminal blocks(12 AWG to 18 AWG) • Low current consumption • Variety of mounting options for new construction and retrofit E applications • Synchronize using the AVSM Series control module • ANSUUL 464 listed for fire protective service • Textured finish high impact plastic faceplate,available in red or off-white Ordering Information Operating Temperature(indoor use only) Stock Number Model Number Model Designations 320 to 120OF(00 to 49°C) 4890001 MHT-1224R R=Red facepalte 4890002 MHT-1224W W=Off-White faceplate 4890003 MHT-1224PR P=Plain 4890004 MHT-1224PW SIGNALING U� LISTED Product includes a 5 year warranty Description The MHT-1224 Series mini-horn is a high quality remote The MHT-1224 can be used on the same sync circuit(AVSM audible signaling appliance that offers dependable remote annunciation. Series Control Module)as other Potter signals.The MHT-1224 Series The MHT-1224 is ideal for applications where a dependable audible is ANSUUL 464 listed for use with fire protective systems. alarm signal is required in applications such as hotels, dormitories, and apartments.The MHT-1224 is listed for use with both filtered and unfiltered power and a jumper is provided to select either temporal 3 or continuous tone. Architect&Engineering Specifactions The alarm horns shall be Potter model MHT-1224.The appliance shall be listed with Underwriters Laboratories(ANSUUL)for use with fire protective signaling systems(ANSUUL 464)and produce a peak sound output of 90dBA or greater as measured in an anechoic chamber.The appliance shall be of solid-state construction and be polarized to operate from 8-33VDC with a 22mA current drain at 24VDC.The appliance shall be provided with 2 terminals,and mount to a variety of single-gang back boxes. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830065-REV A PAGE 1 OF 2 06/13 (E) POTTER MHT 1224 SERIES ® The Symbol of Protection LOW CURRENT MINI-HORN Mini-Horn Wiring UL MHT-1221 MHT-I I 1151I I; WIRING DIAGRAM FOR DUAL CLASS B CIRCUITS WITH A SINGLE AVS"CONTROL MODULE CONTROI PANtI + — + SYNCODULAl10N F A C P MUrAIIE 1MT•t7H ANT•t!N h• lu M SIJI>f kV F.I 'NU IT I INr SIGnn•. tE51STDR CIRI'I ' EOI R SIGNAL CIRCUITS wr-Tti+ rrtfar 1_4Cf< B:-ALK Et,-ACK BLAf,R a., Wiring Diagram EOLR Mini-Horn Wiring Use a screwdriver to break the jumper for a continuous tone. O DO NOT BREAK m JUMPER IF TEMPORAL 3 TONE IS NEEDED. Horn Mode Minimum SPL at 10 Minimum SPL at 10 Reverberant dBA at 10 In Anechoic MHT-1224 Current Ratings feet per ANSI/UL feet per ANSFUL feet per ANSI/UL 464 Room dBA @ I 24 VDC 22 mA 464 at 24 VDC 464 at 12 VDC 10 ft. 24 VDC UL Max 18 mA Temporal 3 81 dBA 78 dBA 78-86 90 12 VDC UL Max 13 mA Continuous 86 dBA 1 83 dBA 78-86 90 NOTES:The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. 1 RMS current ratings are per ANSFUL average RMS method.ANSFUL max current is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units)(8-17 VDC for 12 VDC units).For strobes,the ANSFUL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units)(8 VDC for 12 VDC units).For audibles,the max current is usually at the maximum listed voltage.For unfiltered FAIR ratings,see installation manual. PRINTED IN USA MFG.#8830065-REV A PAGE 2 OF 2 06/13 Effective June 2014 Technical Data TDO01009EN Exceder LED Low Frequency Sounder Strobes and Sounders Description ••�• �.�•�.••� � Eaton's Cooper Notification business has developed the Wheelock . •.•:•;...;•.•;••. Exceder LED Low Frequency Sounder Strobes and Sounders to ;••: meet the new National Fire Protection Association (NFPA) low •:•:;:•:•••• •' frequency sounder requirements for sleeping rooms -NFPA 72 for fire alarm and NFPA 720 for Carbon Monoxide (CO)alarm. In a single ••' device,the Exceder LED Low Frequency Sounders can provide alarm ••.•;:•:;�:�;:•:'•;: signals for dual applications-T3 (Fire)and T4(CO)tones. It is the � first product in the industry to be listed to the audibility requirements �'•:;;;;;:�'• X;�����:;�.� of UL 2034 and UL 2075 for CO applications. H ,., fib :;:;:::,•:•;••;; The Exceder LED Low Frequency Sounder Strobes and Sounders feature multiple 520 Hz modes of operation:T3 (fire),T4(CO), •: �••�••��••�.�.•.�. Continuous,T3/T4 Sync Control. The 520 tone is generated within the appliance itself. When '.•;:;:;:;;;:�;:•.;• the selector switch is set forT3 orT4,the sound pattern is also •.•.••...••.•; generated within the appliance. When the selection switch is set to continuous,the product is listed for coded operations. TheT3,T4 pattern or other pattern must be generated by the FACP according to ....... •.�•..•. •� the alarm condition sensed by the panel (fire or CO alarm). . . . . . When the device is set toT3/T4, the appliance can switch fromT3 to '�' '•"'�'•'•'�' T4 based upon the condition sensed by the FACP and passed to the %•% Wheelock DSM module. ••••.••••.••• 0 0 •. Like the entire Wheelock Exceder LED product line, the Low �.�.•�•.;�;.����; Frequency Sounder Strobes will utilize Light Emitting Diode (LED) N ••;.;•:;;;:•; as the light source—a breakthrough optical design, resulting in best- in-class efficiency that enables material and system cost savings, allowing for a greater number of appliances on the notification appliance circuit and fewer power supplies. All LLFHS strobe models include a 110 candela setting. Providing a sleek aesthetic appearance, the Exceder LLFHS and LLFHN models feature one of the industry's smallest footprints and a sleek, modern, low-profile design. Installers will benefit from its comprehensive feature list, multiple 520 Hz modes of operation, lowest current draw, no tools needed for setting changes, and convenient mounting options.These products are suitable for indoor wall-mount applications.The Sounder and Sounder Strobe models are for 24V operation. Exceder LED Sounder Strobes may be synchronized when used in conjunction with the DSM Sync Modules,Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol.Wheelock synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. The Exceder LED Low Frequency Sounders and Sounder Strobes are UL Listed for indoor use under Standard 1971 and 464 and ULC under S525 and S526. The appliances are Restriction of Hazardous Substances (RoHS)compliant and contain no mercury or other F AIkT* N hazardous substances. Powering Business Worldwide Technical Data TDO01009EN Exceder LED Low Frequency Sounder Strobes and Sounders Effective May 2014 Features Drawings • Meets dual low frequency sounder codes for sleeping rooms in a 4.56 1.29 single device • NFPA 72 for fire alarm • NFPA 720 for CO alarm "'eeeeeaeo • 4 Settings in 1 device 000000000000000 • T3 (fire) o°omoo°o°00000°0°0°°0 o°o mo 000000000000 oo°om • T4(CO) °000°o°o°000°o°o°o°o0 m°m°o°Oo°Oo°O°o°o°o°o°m°u • Continuous (Coded) moeo°o°o°o°o°o°0000°oo°° 6. 10 • T3/T4 °o om o0 00°0°00000 o°°a o o eoo °o0 000 o • Energy efficient °ooaooeoo°0o0000o00° eeeee • Patented LED technology provides industry's lowest current O000000es°o draw • Low-profile design • Smallest footprint with sleek, modern aesthetics • --- t 11 • 110 candela setting I.40-I • Easy-to-install • Finger slide switches—No tools needed for setting changes • Built-in level adjustment feature and snap-on grille cover Figure 1.Wall Low Frequency Sounder Strobe • IN/OUT screw terminals using#12 to#18 AWG wires • Mounting Options include Exceder LSPKBB _ backboxes and 4" square backboxes o°000°0000°o 0o0o0aes°°a°o°0 • Strobe synchronization components o o ¢ 00000 0 0 0 Y p o o°o°OpOo°o°o°0°a°o o • Meet synchronizing standards with Wheelock's DSM Sync mom 00 oaop0°o°o°o°°o m Modules or PS-6/8 Power Supplies ®000000°°000°°o$00000 pP m0m0o0o00000000o0o00° m o 0 0 0 0 0 0 0 0 0 m o0 o°o00 o°o°o°o°o°o°o° • Compliance o°m°000°000°0°00000 • UL 2034, UL 2075, UL 1971, UL 464, ULC S525, ULC S526 °o°m o°°o°Op°o°00000°®oo° °aooee000000oee0000 • California State Fire Marshal (CSFM) o o eeeee o o o°aoeeeeeepe0o • ADA/NFPA/ANSI/OSHA 000 • RoHS Note: All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. A WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION Figure 2.Wall Low Frequency Sounder INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT.VISIT WWW.000PERNOTIFICATION.COM OR CONTACT Table 1. Horn Strobe Current Draw COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. ULIULC Max Current a FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR Exceder LED Sounder Strobes 24VDC WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, 16-33 Volts WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR Model Horn Setting 110 cd DEATH TO YOU AND/OR OTHERS. LLFHS Continuous 0.292 Code 3 0.292 Code 4 0.292 General Notes Code 3/Code 4 0.292 • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range:' Note that NFPA-72 specifies a Table 2. Horn Only Current Draw flash rate of 1 to 2 flashes per second and ADA Guidelines specify ULIULC Max Current a a flash rate of 1 to 3 flashes per second. Exceder LED Sounders 24VDC • All candela ratings represent minimum effective Strobe intensity Model Horn Settings 16.0-33.0 based on UL 1971. LLFHN Continuous 0.113 Code 3 0.113 Code 4 0.113 Code 3/Code 4 0.113 2 EATON www.eaton.com Technical Data TDO01009EN Exceder LED Low Frequency Sounder Strobes and Sounders Effective May 2014 Table 3. Sound Output (SPL)- UL Table 4. Sound Output (SPL)- ULC LLFHS/LLFHN 24V LLFHS/LLFHN Reverberant dBA per UL 464 dBA per ULC S525-07c Description 16.OV 24.OV 33.OV Description 16.OV 24.0V 33.OV Continuous 80 80 80 Continuous 80 80 80 Code 3 76 76 76 Code 3 80 80 80 Code 4 b 85 85 85 Code 4 80 80 80 Code 3/Code 4 76 76 76 Code 3/Code 4 80 80 80 Table 5. Specification &Ordering Information Sync w/DSM or Model Strobe Candela Red White Lettering Wheelock Power Supplies Sounder Strobes LLFHSR 110 X FIRE X LLFHSW 110 X FIRE X LLFHSR-AL 110 X ALERT X LLFHSW-AL 110 X ALERT X LLFHSR-CO 110 X CO X LLFHSW-CO 110 X CO X LLFHSR-N 110 X No Lettering X LLFHSW-N 110 X No Lettering X Sounders LLFHNR-AL X ALERT X LLFHNW-AL X ALERT X LLFHNR-CO X CO X LLFHNW-CO X CO X LLFHNR-N X No Lettering X LLFHNW-N X No Lettering X Accessories Description Red White LSPKBB-R 0756 Exceder LED Backbox X LSPKBB-W 0757 Exceder LED Backbox X Table 6. Specifications Physical Material Red or white textured UV stabilized,colored impregnated engineered plastic. Exceeds 94V-0 UL flammabil- ity rating Weight 1.10 lbs. Lens Light Emitting Diode(LED)in a rugged Lexan lens Dimensions 6.1"H x 4.56"W x 1.4" D Operating Temperature Indoor:33.8°F to 120.2°F WC to 49°C)and maximum humidity of 85% Mounting&Wire Connections Mounting(indoor only) Wall-mount applications only. Exceder LSPKBB backboxes or to 4" square backboxes Wire Connections #12 through#18 AWG Power&General Operating voltage 24 VDC: 16-33 VDC Strobe Output Rating UL 1971: 110 candela output Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules, PS-6/8 Power Supplies, using Wheelock patented sync protocol Temporal Audible Pattern Continuous, Code 3, Code 4 or Code 3/Code 4 Sync Control. The Code 3 temporal pattern (1/2 second on, 1/2 second off, 1/2 second on, 1/2 second off, 1/2 second on, 1-1/2 off and repeat) is specified by ANSI and NFPA 72 for standard emergency evacuation signaling. The Code 4 temporal pattern (four cycles of 100 milliseconds 10 percent"on"and 100 milliseconds 10 percent"off;'followed by 5 seconds 10 percent"off) is specified by NFPA 720. a RMS current ratings are per UL maximum RMS method.UL max current rating is the maximum RMS current within the listed voltage range(16-33A. For strobes the UL max current is usually at the minimum listed voltage. For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings,see installation instructions. b Code 4 setting rated per UL 2075, UL 2034. c For dwelling use only. 3 EATON www.eaton.com Technical Data TDO01009EN Exceder LED Low Frequency Sounder Strobes & Sounders Effective May 2014 Architects and Engineers Specifications backboxes and to standard 4" square backboxes. The sounder and The low frequency sounders and sounder strobes appliances shall sounder strobe shall incorporate a mounting plate with a snap-on be Wheelock® ExcederTm LED Series LLFHN Sounder and LLFHS grille cover and shall mount to standard electrical hardware requiring Sounder Strobe for wall-mount applications with a low-profile design no additional trimplate or adapter. Removal of an appliance shall or approved equals.The sounders shall be UL Listed under UL 464 result in a supervision fault condition by the Fire Alarm Control Panel (FACP). All notification appliances shall be backwards compatible. for Fire Protective Service and to the requirements of UL 2034/UL 2075 for CO applications and ULC S525. Sounders equipped with The Series LLFHN wall model shall have a low profile measuring strobes shall be listed under UL 1971 for Emergency Devices for the 6.1" H x 4.56"W x 1.29" D.The Series LLFHS wall model shall have Hearing-Impaired and ULC S526.The Series shall be Restriction of a low profile measuring 6.1" H x 4.56"W x 1.4" D. Finish shall be Hazardous Substances (RoHS) compliant and contain no mercury or red or white. Special lettering,ALERT, CO and No lettering, shall be other hazardous substances. In addition, the sounder strobes shall available. meet the requirements of FCC Part 15.All inputs shall be compatible When synchronization is required, the appliance shall be with standard reverse polarity supervision of circuit wiring by a Fire compatible with Wheelock's DSM Sync Modules, PS 6/8 Power Alarm Control Panel (FACP)with the ability to operate from 16 to 33 Supplies,or other manufacturer's panels with built-in Wheelock VDC. Patented Sync Protocol.The strobes shall not drift out of synchro- nization at any time during operation. If the sync protocol fails to The Series LLFHS Sounder Strobe shall produce a flash rate of one operate,the strobe shall revert to a non-synchronized flash-rate and (1)flash per second over the Regulated Voltage Range and shall still maintain (1)flash per second over its Regulated Voltage Range. incorporate a Light Emitting Diode (LED)as the light source with a The appliance shall also be designed so that the audible signal may rugged Lexan®lens.The Series shall be of low current design.The be silenced while maintaining strobe activation when used with strobe intensity shall have a 110 candela for wall mount applications. Wheelock patented sync protocol. The audible shall have a minimum of four(4) 520 Hz modes of operation:T3 (fire),T4(CO), Continuous,T3/T4 Sync Control. UL 1971, UL 464, ULC S525, ULC S526, CSFM, FCC, RoHS The Series LLFHS and LLFHN shall be designed for indoor surface or flush mounting. Mounting options shall include LED speaker Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. 111=11A WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Cooper Notification 273 Branchport Ave. Long Branch,NJ 07740 CooperN otif i cation.com ©2014 Eaton All Rights Reserved Eaton is a registered trademark. - Printed in USA Publication No.TDO01009EN All other trademarks are property Powering Business Worldwide June 2014 of their respective owners. pp- 000 COOPER Notification EJCED _ Strobe, Horn Strobe, and Horn Notification Appliances - Ceiling Wall Description: The Wheelock°Exceder`Series of notification appliances feature a sleek modern design that will please building owners with reduced - Save up to 48% in current draw* total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes,voltage test - Up to 9 models now in 1 appliance points, 12/24 VDC operation,universal mounting base and multiple mounting options for both new and retrofit construction. - Save up to 14% cost of installation** The Wheelock°ExcederTm Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe models feature an industry first of 8 candela settings on a single U Sleek Modern Aesthetics appliance.Models with an audible feature 3 sound settings(90,95, 99 dB).All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. C40 Finger Slide Switches Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock° ExcederTm Series of wall and ceiling notification Voltage Test Points appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting Multiple Voltages base can be pre-wired to allow full testing of circuit wiring before ' the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt,dust,paint 3 Audible Settings and damage to the contacts. The Contact Cover also acts as a 90,95,99 dB shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while 8 Candela Settings *** it is on the UMB. When the Contact Cover is removed the circuit Wall-15/1575/30/75/95/110/135/185 will show an open until the appliance is installed.The UMB allows Ceiling-15/30/60/75/95/115/150/177 for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra Universal Mounting Base *** secure installation, while the ceiling models provide a captivated Ceiling and Wall screw to prevent the screw from falling during installation. UU Mounts to 5 Backbox Types Compliance Environmentally Friendly -UL 1971, UL 464, ULC, CSFM, FM Low Current Draw -ADA/NFPA/ANSI/OSHA -RoHS Compatibility and Requirements -Synchronize using the Wheelock°Sync Modules or panels with built-in Wheelock°Patented Sync Protocol -Compatible with UL"Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage -Strobes produce 1 flash per second over the"Regulated Voltage" range Compared to competitive models ""Patented Compared to previous models NOTE:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range". •All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 1207(0°C to 49°C)and maximum humidity of 93%(±2%)UL 464(85%UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances(Indoor use only). Low Current Draw = FewerPower • • Strobe Ratings per UL Standard 1971 UL Max Current* 24 VDC/24 FWR 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 0.253 0.110 0.140 STC 8.0-33.0 0.061 0.085 0.103 0.135 0.163 0.182 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 &Anechoic at 24 VDC AnechoicUL Max Current*at •• •:A 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 10.125 AnechoicUL Max Current*at •:A 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.272 0.122 AnechoicUL Max Current*at •• •:A 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 Horn Ratings per UL Anechoic Model Regulated Voltage 99 dB 95 dB 90 dB Range VDC HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 *UL max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage(33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Sync w/ Model Strobe DSM or 12/24 VDC* Mounting Candela Wheelock Power Options Supplies HSR 15/1575/30/75/95/110/135/185 X X UMB** ' HSW 15/1575/30/75/95/110/135/185 X X UMB** H S RC 15/30/60/75/95/115/150/177 X X UMB** ' HSWC 15/30/60/75/95/115/150/177 X X UMB** STIR 1511575/30/75/95/110/135/185 X X UMB** STW 15/1575/30/75/95/110/135/185 X X UMB** STRC _ 15/30/60/75/95/115/150/177 X X UMB** STWC 15/30/60/75/95/115/150/177 X X UMB** HNR X X UMB** HNW X X UMB** HNRC .. X X UMB** HNWC 117 X X UMB** *12 VDC models feature 15&15/75 settings **UMB=Universal Mounting Base Model Legend HN = Horn A =Agent Lettering - ST = Strobe (Strobes only) 4r HS = Horn Strobe AL=Alert Lettering C = Ceiling Mount (Strobes only) W =White N = No Lettering R = Red (Strobes only) Example 1: STRC=Strobe,Red,Ceiling Mount / Example 2: HSR=Horn Strobe, Red,Wall Mount / Example 3: HSW=Horn Strobe,White,Wall Mount ' r Example 4:STW-AL=Strobe,White,Wall Mount,Alert Lettering ■ p g Example. Example: HSWC • 1 *UMB Contact Cover NOTE: Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Cooper Notification standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock° ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design. Where Multi-Candela appliances are specified,the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g.ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe,ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP). The mounting base shall be the same base among all horn, strobe, horn strobe,wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24"H x 4.58"W x 2.19"D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63" D. Series HNC ceiling shall have a diameter of 6.68"x 1.50" D. When synchronization is required,the appliance shall be compatible with Wheelock®'s DSM Sync Modules,Wheelock®Power Supplies or other manufacturer's panels with built-in Wheelock®Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate,the strobe shall revert to a non-synchronized flash-rate and still maintain(1) flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock®synchronization protocol. Wall Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS W WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder- Spec Sheet 5/13 NJ Location 273 Branchport Ave. Long Branch, NJ 07740 800-631-2148 www.coopernotification.com Cooper Notification is Wheelock' MEDC SAFEPATH® WAVES { COOPER Notification S-24 & HS-24 CPOTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Features • 24VDC units have field selectable candela options of 15,30,60, 75,& 110 • Super-Slide®Bracket-Ease of Supervision Testing • Checkmate®-Instant Voltage Verification • Synchronize strobe and/or horn with AVSM Control Module • Prewire entire system,install mounting bracket,then install - signals f, _ — Documented lower installation and operating costs Input terminals accept 12 to 18 AWG Switch selection for high or low dBA Switch for chime,whoop,mechanical and 2400Hz tone Tamperproof re-entrant style grill R I I I I I I I I Switch for continuous or temporal 3 tone(not available on whoop tone) • Surface mount with the AVBB(Surface Mount Back Box) • Silence audible while visual appliance will remain flashing(for use in accepted jurisdictions) • Faceplate available in red or off-white Operating Temperature • 320F to 120OF(0°C to 49°C).The HS and S Series are not listed for outdoor use. Unit Dimensions • 5"(12.7 cm)high x 4.5"(11.43 cm)wide x 2.5"(6.35 cm)deep U� LISTED S3247 Description The S-24/HS-24 Series is a low profile strobe and horn/strobe This Series is shipped with a standard 4" metal mounting combination that offers dependable audible and visual alarms and the plate which incorporates the popular Super-Slide®feature that allows absolute lowest current available. the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without The S-24 & HS-24 Series 24VDC offers tamperproof field any screws showing. selectable candela options of 15,30,60,75,and 110 candela. The S-24/HS-24 also features the patented Checkmate® - The Strobe and Horn/Strobe offers a continuous or sync Instant Voltage Verification feature which allows the installer to check temporal three in 2400Hz and mechanical tone, a chime and whoop the voltage drop draw and match it to the blueprint. tone.All tones are easy for the professional to change in the field by the use of switches. The S-24&HS-24 Series appliances are ANSI/UL 464 and ANSI/TJL 1971, listed for use with fire protective systems and are The S-24 & HS-24 Series has a minimal operating current warranted for three years from date of purchase. and has a minimum flash rate of 1 Hz regardless of input voltage. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 1 OF 4 06/13 S-24 & HS-24 (E) POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Tone Switch Locations TONE SWITCH POSITION 3 4 5 ®o Mechanical Temporal 3 ON ON ON �® 1, Mechanical-Continuous OFF ON ON 2400Hz-Temporal 3 ON OFF ON ® S+ 2400Hz-Continuous OFF OFF ON S- Chime-Temporal 3 ON ON OFF -® H+ � Chime-Continuous I OFF ON OFF Whoop I ON OFF OFF Whoop OFF OFF OFF NOTE: • Switch Positions 1 and 2 in the OFF position to select isolated horn and strobe power inputs • Switch Position 6 ON=HIGH dBA • Switch Position 6 OFF=LOW dBA Super Slide®Mounting Bracket Checkmate®Instant Allows the installer to pre-wire Voltage Verification the system,test for system It is often necessary to confirm the voltage supervision,remove the signal drop along a line of devices.The access head until occupancy,switch holes are provided in the back of the out signals without terminal block to allow the voltage to be changing mounting brackets measured directly without removing the and has locking edge connector device.Typically,this would be done at the for snap-in-place installation. end of line to confirm design criteria.Most - measurements will be taken using the S+ and S-locations althouhg access is provided to other locations. NOTE:Care should be taken to not short the test probes. Candela selection slider switch. Depress center and slide switch to desire brightness level. r- T Break off pin and insert l S into hole at the bottom of .a the selector to lock candela setting.Signal must be removed from bracket and pin pushed forward from backside out of hole to change candela. To remove bezel,grip both sides of bezel and pull in a download and outward motion. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 2 OF 4 06/13 S-24 & HS-24 CF POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES S-24 24 VDC Selectable Candela,Low Profile Evacuation Strobe Model Part Nominal Candela Number Number Voltage (ANSI/UL 1971) S-24WR I 4890010 24 VDC 15,30,60,75, 110 S-24WW 4890011 24 VDC 15,30,60,75, 110 HS-24 24 VDC Selectable Candela,Low Profile Evacuation Horn/Strobe Model Part Nominal Candela Reverberant dBA at In Anechoic Room Number Number Voltage (ANSFUL 1971) 10 ft.,per ANSI/UL 464 dBA at 10 ft. HS-24WR 4890030 24 VDC 15,30,60,75, 110 62-82 100 HS-24WW 4890031 24 VDC 15,30,60,75, 110 62-82 100 S-24&HS-24 Product Strobe Current Ratings(mA) 24 VDC(16-33 Volts) Model Designations: W=Wall Mount Candela 24 VDC UL Maxi R=Red Faceplate W=White Faceplate 15 cd 30 mA 42 mA 30 cd 35 mA 58 mA All units are available in plain(no lettering). Plain units are non-returnable. 60 cd 66 mA 97 mA 75 cd 80 mA 116 mA ALERT bezel available for order. 110 cd 103 mA 161 mA ALERT bezel available for order. S-24&HS-24 Product Horn Current Ratings Horn Decibel Levels Horn Current Ratings Minimum SPL Minimum SPL Regulated 24 VDC Horn Mode at 10 ft.,per at 10 ft.,per Max.Operating @ ANSI/UL 464 ANSI/UL 464 High Setting(mA) (HIGH) (LOW) Temp 3 2400 Hz 78 dBA 71*dBA 28 mA Temp 3 Mechanical 76 dBA 70*dBA 25 mA Temp 3 Chime 70*dBA 66*dBA 15 mA Continuous 2400 Hz 81 dBA 74*dBA 28 mA Continuous Mechanical 80 dBA 72*dBA 25 mA Continuous Chime 70*dBA 66*dBA 15 mA Whoop 82 dBA 69*dBA 56 mA NOTES: • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified]) power,see installation manual. • Potter does nto recommend usign a coded or pulsing signaling circuit with any of our strobe products. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service.These settings are acceptable only for private mode fire alarm use.Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 3 OF 4 06/13 S-24 & HS-24 (E) POTTER SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Architect&Engineering Specifications The audible and/or visible signal shall be Potter S-24 strobe and Potter HS-24 horn/strobe Series or approved equal and shall be listed by Underwriters Laboratories,Inc.per ANSI/UL 1971 and/or ANSI/UL 464.The notification appliance shall also be listed with Factory Mutual Listing Service(FM)and the California State Fire Marshal(CSFM). The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater at 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage.The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control Control Panel signal signal Panel Signal Signal g+ S+ S- H+ H- S+ S+ S- H+ H- s+ S+ S- H+ H- S+ S+ S- H+ H. Supervised Supervised 0 B 0 B Signal Circuit Signal Circuit \ + \ + END LINE END OF LINE RESISTOR RESISTOR \ + 7D END OF LINE RESISTOR NOTES: • All strobes are designed to flash as specified with continuous applied voltage.Strobes should not be used on coded or pulsing signaling circuits.However,use of the Potter AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe,horn,and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION,REFERENCE AVSM CONTROL MODULE DATA SHEET(8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS.AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 4 OF 4 06/13 GENTEX CORPORATION GOE OUTDOOR ENCLOSURE Applications A C C E S S O R I E S The Gentex GOE Outdoor Enclosure is ANSI/UL 464 listed for use in indoor and P A G E outdoor applications when used with the Gentex GEH Series horn and WGE Series strobe and horn/strobe. Standard Features • ANSI/UL 464 listed • Back box with side mount tabs • Made of clear Lexan°- providing maximum visibility and reliability • Unit Dimensions: 5.75" (14.61 cm) high x 4.75" (12.10 cm)wide x l •�,''- 4.18" (10.62 cm) deep • 3/4"conduit knockouts l'llll� • Reinforcement steel hardware --- R • Outdoor resistant gasket • Available in red or off-white GOE-R GOE-W GOELP OUTDOOR ENCLOSURE Applications The Gentex GOELP Low Profile Outdoor Enclosure that creates a surface mount look, is ANSI/UL 464 listed for use in indoor and outdoor applications when used with the Gentex GEH Series horn and WGE Series strobe and horn/strobe. Standard Features • ANSI/UL 464 listed • Back box with outdoor resistant seal for mounting to wall GOELP GOE • Made of clear Lexan°- providing maximum visibility and reliability • Unit Dimensions: 5.75" (14.61 cm) high x 4.75" (12.10 cm)wide x 3.25" (8.255 �+- cm) deep • 3/4"conduit knockouts • Reinforcement steel hardware • Outdoor resistant gasket • Available in red or off-white GOE AND GOELP NOTES: • Product does not meet ANSI/UL 1971 light distribution requirements • To allow for drainage, the seal on the bottom edge is not water tight GOELP-R GOELP-W GBLP OUTDOOR BACK BOX Applications f ►'� The Gentex GBLP Outdoor Back Box is constructed of durable plastic is ANSI/UL _ •, 464 listed for use indoor and outdoor applications when used with the WSSPK Series speaker and speaker/strobe. Gl Standard Features o' v • ANSI/UL 464 listed ,.. • 1/2"conduit knockouts with metal washer reinforcements i • Wiremold knockouts for 500, 700 Series and pendulum mount • Unit Dimensions: 6.20" (15.75 cm) square x 2.04" (5.18 cm) deep • Reinforcement steel hardware GBLP-R GBLP-W • Outdoor resistant gasket • Available in red or off-white ACCESSORIES PAGE GSB SURFACE BACK BOX Applications The Gentex GSB Surface Back Box is constructed of durable plastic and is fully compatible with the Commander' (GE)and Commander'(GE3) Series horns, strobes and horn/strobes. Standard Features • ANSI/UL listed for indoor use • 1/2" conduit knockouts with metal washer reinforcement • Wiremold knockouts for 500 and 700 Series • Unit Dimensions: 5.57" (14.15 cm) high x 4.55" (11.56 cm) wide x 1.47" (3.73 cm) deep • Screw heads hidden GSB-R • Available in red or off-white ALERT & AGENT BEZELS Applications The Gentex ALERT and AGENT bezels are constructed of durable plastic and is q fully compatible with the Commander (GE)and Commander' (GE3) Series horns, l strobes and horn/strobes. E Standard Features R T • Easy to install I • ALERT or AGENT wording on both sides of bezel • Available in red or off-white ALERT-W AGENT-R GCSB CEILING SURFACE BACK BOX Applications The Gentex GCSB Surface Back Box is constructed of durable plastic and is fully compatible with the Commander (GC) Series strobes and horn/strobes. Standard Features • ANSI/UL listed for indoor use • 1/2"conduit knockouts with metal washer reinforcement • Wiremold knockouts for 500, 700 Series and pendulum mount • Unit Dimensions: 6.2" (15.75 cm) round x 1.67" (4.24 cm) deep • Screw heads hidden • Available in red or off-white GCSB-R GCSB-W Important Notice: 551-0031-02 G E N T E X These materials have been prepared Gentex Corporation("Gentex")for informational purposes only,are necessarily summary,and arere not purported to servee as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these materials are complete and accurate,up-to-date,or in compliance with all relevant local,state and federal laws, CORPORATION regulations and rules. The materials do not address all legal considerations as there is inevitable Fire Protection Products Group•www.gentex.com uncertainty regarding interpretation of laws,regulations and rules and the application of such laws, regulations and rules to particular fact patterns. Each person's activities can differently affect the 10985 Chicago Drive •Zeeland, Michigan 49464 obligations that exist under applicable laws,regulations or rules. Therefore,these materials should be used only for informational purposes and should not be used as a substitute for seeking professional 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax legal advice. Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. 9 8 7 6 5 4 3 2 1 FIRE PROTECTION INC. DEVICE INSTALLATION REQUIREMENTSPARK 77 APARTMENTS Everett, Road VICINITY MAP 1 425-290-900730 GibsWA.98204 Gibson 600 xvAcwrrtr CEILING MOUNTED II � NOT PCRMITTED DAVID MOW SMOKEME 3'(YIN) HERE CEILING < m AUDIO/NSUAI I~I k VISUAL DEVCES ' PERMITTCD ERMNoTD , 12• 120904 x HERE HCRE MAX BUILDING 9 LEVEL III raec PERMITTED, D HERE DFAR INS PEE etvrtw B PIC1rISR PIG1rIFR 7wx NFPA NXH to.µ. �� FIRE ALARM di•IaN {AS•D ys.n 1/.7SN• OOOS05173 {.6•D YS N # � °u O ROY L CATS aa-nN WANT WAR WW PH MANUAL PH PULL -c--.;ce xJvi:nl' Q�QgOTECr�Oy • a�enE r,sr..:.r. JACK STATION iactunng Tech 48-YA% G N� y FlNISHED FLOOR A R L I N G T O N, WA �, CFPS #1473 CITY OF REDMO14D ° INSTALLATION NOTES raxloM°Boa °sa016-B-141 Fire Alarm Symbol Legend 204TH STREET N.E. 1) Prior to calling for inspection,the installer shall provide SYMBOL DESCRIPTION PART NUMBER M_FG QTY BACKBOXREQURREMENTS MOUNTING REQUIREMENTS documentation to the local AHJ stating that the system has been ® LCO REMOTE ANNUNCIATOR RA-6075 POTTER installed,tested,evaluated and confirmed to be in accordance with all > > C governing codes and the approved plans.The Fire Alarm System PS INTELLIGENT 10 AMP REMOTE POWER EXPANDER PSN-1000 POTTER 1 AREA OF WORK = w installer shall complete an NFPA72 Record of Completion(NFPA72 m w rs SPRINKLER TAMPER BY OTHERS BY OTHERS 10.18.2.1.1). The completed Record of Completion shall be provided to BUILDING 9 m q C Z the AHJ inspector at the time of inspection NFPA72 10.18.2.1.2.4. DM DUAL INPUT CONTACT MODULE DCM-4 POTTER 1 BBOX-4,Standard backbox,4 K Q U S P P ( ) BLDG.13 3 o c u7 u PULL STATION SINGLE ACTION P31.1T POTTER 1 BBOX-2,Standard backbox,2 48'AFF 2t]JFO 2) Instructions for the operating,testing and maintenance of the z'o ua N a system,along with record drawings otherwise referred to as (S) SMOKE,PHOTO,2-WIRE 2W-B SYSSENSOR 1 SBOX-2,Standard backbox.2 = 0 C w is LL ("as-built")and equipment specifications shall be provided at an BLDG.12 — °w m a N LF LED.LF,HORN/STROBE,MC,WH LLFHSW WHEELOCK 9 BBOX-4,Standard backbox,4 STAFF - > E: approved location(NFPA72 10.18.2.3). BLDG.11 m w w g z w 3 O w ® ° STROBE,EXCEDER 24V M-C,WALL,WHITE STW WHEELOCK 7 BBOX-2,Standard backbox,2 82-AFF BLDG.14 _ < Q u cL 3) All systems and devices shall be installed and tested per the 2� < �" o u r y�'11 R manufactures listing and the authority having jurisdiction(NFPA72 AMA HORN/STROBE,EXCEDER 24V M-C,WALL,WHITE HSW WHEELOCK 4 BBOX-2,Standard backbox.2 STAFF Z ________ BLDG.17 I REVISION RECORD 10.14.2.1).Label all device locations containing EOL resistors. Q _ -c Community_ ommunity _ d DATE I DESCRIPTION LF HORN LOW FREQUENCY,WH GHLFW GENTEX 16 BBOX-4,Standard backbox,4 BTAFF ^ r Building _ I -- - -- m 4)FACP&all Remote Power Supplies REQUIRE a DEDICATED 120VAC BLDG.15 I BLDG.9 j 20amp circuit.A notice placed in the FACP shall direct personnel to the MINI HORN,WH MHT-1224W POTTER 8 BBOX-2,Standard backbox.2 82-AFF location of the electrical panel that is supplying DEDICATED power to �NlW BLDG.10 ��II��II '�`-----`--'� ' the system(NFPA72,Section 10.5.5.1). The DEDICATED circuit breaker na° HORN/STROBE,2 WIRE,MC,RED,WALL HS-24WR POTTER 1 BBOX-2,Standard backbox,2 8TAFF 1 BLDG. @ that serves the fire alarm system shall be Labeled and Secured against FS WATERFLOW SWTICH BY OTHERS BY OTHERS 1 _ L SHEET LIST BLDG. tampering with a RED breaker lockout(NFPA72,Section 10.5.5.2). 16 1 - — FA 0.0 FA DETAILS FACP FRCP LOCATED IN BUILDING 17 P300 POTTER E — 1 _ OUTDOOR HIS WEATHERPROOF ENCLOSURE GOELP POTTER 1 d 'BLDG.5-. I,- BLDG.6 BLDG.7 __ FA 1.0 FIRE ALARM 5)This property will have one FACP located in the Community Building. I _ FA 2.0 RISER/CALCS Each residential building will have a Remote Power Supply and a —_______--__- __J I B Remote Fire Alarm Annunciator connected to the main FACP in the Community Building.The FACP will monitor each buildings fire B sprinkler system via SLC,the occupant notification devices in each r IL . .BLDG 1 --� --R-- --R - --- H- R-- the building will only activated when a fire alarm device from that - BLDG.2 J I BLDG..3 BLDG.4 specific building(waterflow,smoke detector,pull-station) is activated. _ - _ [ 6) Wall mounted strobes shall be placed 80"minimum to 96"maximum above floor level.(NFPA72 18.5.4.1 &2).Wall mounted strobes shall be SITE PHASING PLAN -� sized in accordance with(NFPA72 Table 18.5.4.3.1(a).Ceiling mounted SYSTEM OUTPUTS strobes shall be placed and sized in accordance with(NFPA72 Table Required Fire Safety Control 18.5.4.3.1(b). Control Unit Annunciation 7) When MORE than two notification appliances are visible at the same a°9 IF SCALE: 1/8"=1' time whether they are in the same room or adjacent space within the y C� Q° a h; DATE: 10/10/16 field of view,the flash of those strobes shall be synchronized(NFPA72, C N C; P g�"E�, Section 18.5.4.3.2(3)&(4). ,yA PROJECT NAME �g '�y CIRCUIT LINE TYPE Circuit Legend 8) Pull stations shall be placed between 42 and 48 inches above floor ';a °;moo'°°4 ° y.gym c .or f.E'ru level.Devices shall be red in color(ICC A117.1 309&NFPA 72 17.14.5) F c F y��o c'm=; Abbreviation Type Name Z w 9) Outdoor strobes required for approaching Emergency Vehicles to be located in the upper 25%of the building(at a serviceable height), ��� --- D U #18/4 FPLR SLC-SIGNAL LINE CRKT W w a?� 4"y `3" L� A #16/4 FPLR TWISTED PAIR NAC-NOTIFICATION CRKT and to be clearly visible from the emergency vehicle approach path. a d e F q B R #1814 FPLR SBUS of Z Q Z A J may= O 10 Fire Alarm circuits to be installed/secured/terminated in accordance Q~A° ` 1 ~ ~ A SYSTEM INPUTS A B C D E F G H I J Q J n with NEC,NFPA 72,IFC and Local AHJ requirements&standards. 1 Manual Fire Alarm Boxes ♦ ♦ ♦ ♦♦ 1 m r Z r- 2 Smoke Detectors ♦ ♦ - - ♦ - ♦♦ 2 3 Waterflow ♦ - - ♦ - - ♦♦♦♦ 3 Y N 11)The means of communication to the central stations for the fire Fire Alarm Device Numbering 4 Sprinkler Control Valve ♦ - ♦ 4 O alarm system is to be provided by a Potter UD-1000 DACT as per plan. 5 Fire Alarm AC Power Failure ♦ ♦ 5 (SLC)ADDRESSABLE DEVICES NOTIFICATION DEVICES Q N System requires 2 x POTS telephone lines,1 of these lines is required 6 Fire Alarm System Low Battery ♦ ♦ 6 a to be DEDICATED to the FACP.The FACP is located in building 17. 7 Open Circuit ♦ ♦ 7 CIRCUIT clRculr 8 Ground Fault ♦ ♦ 8 F �DEVICE ADDRESS DEVICE 11 12)All building linking conduit&wiring to be provided/installed by 9 Notification Appliance Circuit Short ♦ ♦ 9 / \ CANDELA o Remote Power Supply Trouble ♦ ♦ 10 slc•Alt \�I SHEET DESCRIPTION others. A B C D E F G H I J ` ) FIRE ALARM K I•sxr I I IacD OPERATIONAL MATRIX SMOKE DETECTOR SHOWN AS EXAMPLE s DETAILS SHEET NUMBER FA 0.0 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 FIRE PROTECTION INC. 1730 Gibson Road Everett,WA.98204 425-290-9600 DAVID MOW m L 120904 LEVEL III D -- - --- - — UNITB41 NFPAJ D scsmos — 000805173 III UNITB-10 I UNITB-8 j--- %1 UMTS42 9tasMs ` ROY L CATS H Q�Q9.,OTECI'ip2 r-- siGsoas 614 FPLR SIG 5 WO PS IN RISER ROOM w I moo 12 NFPA'yy 1 j _ ' CFPS L 1 I #1473 CITY OF REDMOND L I I — - - I _ i DAVID MOW RI I I STAIR/ '� I I etcxsa or as a De#16-B-141 ENT co H �011 A I ENTRY - ENTRY sKs.om I - ar�o,oT 2 - W_°S2N C 2 N Ll z�Fa O J � SO zow�l 510mm OmzO > Y wY mz.wti6K 3RD FLOOR 3o � a Q>>< 0= N ou ZH-+o.w REVISION RECORD DATE I DESCRIPTION OP164 THHN(SBUS)TO THE FACP LOCATED IN BUILDING 17 614 FPLR SIG 3 — 612 THHN SLC TO THE FAC O PS IN RISER ROOM - OCATED IN BUILDING 17 r10rT0 FPLR SIG 2 --- PS IN RISER ROOM I SHEET LIST FA 0.0 FA DETAILS I �+ zN,•aor FA 1.0 FIRE ALARM I I g S) J FA 2.0 RISER/CALCS UNIT:B-71L _UNIT B-2 UNIT B,3 I B I I siG,om UNIT B-1 I Type A siGaoo Type A I rs Fs UNIT B4 �— jl ,tOCD --- ZNZ•001 ZNt•001 �` I �H sw<.00s I UNIT BSTYPe A UNIT BS d ---- - UIT134 Type ASaao< r IG2,11 614 FPLR SIG -� - I I �. I 1111J I I 1 A I --— --O PS IN RISER ROOM A� T1II E«us SiNGG.3Dc.000 ' .. jII ssic—o�on— D rox_ mi l_yI STA—It1 1IYI'III-"_r_' SCA IIII A —ooH LE _ 1 , DATE 10/0/16 PROJECT NAME c s1D ue° O R/ STAIR/ STAIR s . sTAlw j ENTRY a I wD ENTRY G<W ENTRY ENTRY T sisl� z W Q W W SIG-5 1 110CD ' 3Kil006 . 4 SIGt•008 1,UGD I eO siGa att I i e N z Q O SIGt4W LF „OCp --- •. SIG,-0p5 A U I I LL _ A SiGI.005 I SIG9 Ot3 I I Q _ � z CD UP — V Y o Q UP 1ST FLOOR 2ND FLOOR a N N N SHEET DESCRIPTION FIRE ALARM SHEET NUMBER FA 1 .0 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 FIRE PROTECTION INC- 1730 Gibson Road Everett,WA.96204 425-290-9600 Battery Calculations for Panel:PS BUILDING 09 Part No:PSN-1000-INTELLIGENT 10AMP REMOTE POWER EXPANDER DAVID MOW Part No. oty. Description Standby Total Standby. Alarm Total Alarm Panel Equipment PSN-1000 MB 1 10 AMP POWER EXPANDER_MB 75.0000.4 75.0000mA 215.0000mA 215.0000mA �v Told Panel Stay 75.00WmA Total Papal Alarm 215.000OmN Peripheral Devices 2W-B 1 SMOKE,PHOTO,2-WIRE(Initialing) 0.010D.A 0.0100mA 6.5000mA 6. 120904, P31AT 1 PULL STATION SINGLE ACTION(Initiating) 0.000OMI 0.0000mA 0.0000mA O. I LEVEL III LLFHSW 9 LED,LF,HORWSTROBE,MC,WH(Notification) 0000OrM 0.0000mA 292.0000mA 2628.0000mA STW 7 STROBE,EXCEDER 24V MC,WALL,WHITE(Notification) D.000DMA O.000OMA 57.ODOOMA 399.0000.A HSWJ I HORN/STROSE,EXCEDER 24V,MC,WALL,WHITE(Notification) D.000OmA 0.0000.Al 102.0000mA 408.000DmA GHLFW 1 HORN LOW FREQUENCY,WH(Notification) 0000DMI 0.0000MA 99.4000mA 1590.4000mA MHT-1224W MINI HORN,WH(Notification) 0.0000.4 0.0000mA 22.0000mA 176.000DmA HS-24WR 11 HORN/STROBE,2 WIRE,MC,RED,WALL(Notifica8on) O.0000mA 0.000OmA 186.00M.A 186.00WmA D Total Peripheral Stby 0.0100mA Total Penph Alarm 53M.9000.A N F PA Total StandbyAmPs 75.0100mA TOW Alarm Ampsl 5608.9000.A 000805173 Standby time:24 Him lam ROYL CATS Alarm time:5 Min 0.467Ah P�QpOTECl/0y Battery requirement. 2.288Ah Compensation Factors-Standby:12 Alarm:12 Requirement with compensation: 2121Ah o ■ .A, ■ NFFW a b NFPA C and y5 Circuit Calculations Panel:PS Card:00 Circuit:SIG1 Circuit Calculations Panel:PS Card:00 Circuit:SIG2 Circuit Calculations Panel:PS Card:00 Circuit:SIG3 CFPS ClicuitName:SIGI Circu'itilame:SIG2 CirwitName:SIG3 #1473 Circuit Type:Notification Terminal Voltage:20.4V:DC Amperage:3.000OA Circult Type:Notification Terminal Voltage:204V:DC Amperage:3.0000A Circuit Type:Notification Terminal Voltage:20.4V.DC Amperage:3.0000A Cable:16/4C TWISTED FPLR#16 Cabls:16/4C TWISTED FPLR#16 Cable:16/4C TWISTED FPLR#16 Calculations based on Running Total Length. Calculations based on Running Total Length. Calculations based on Running Total Length, Design Criteria:Ambient temperature:167'F Max.operating voltage drop:15% Design Crilena:Ambient temperature:1676F Max.operating voltage drop:15% Design C item:Ambient temperature:167'F Max.operating voltage drop:15% •j'►��// Device Part No Appliance Desc Distance Current Voltage Voltage Drop Device Part No Appliance Desc Distance Current Voltage Voltage Drop Device Part No Appliance Desc Distance Current Voltage Voltage Drop CITY OF REDMOND PSN.lOD0 Panel - - - -20- PSN-1000 Panel 20.4 PSN-1 Panel 20AV DAVID MOW 001 HSW HORN/STROBE,EXCEDER 24V,MC,WALL,WHITE,30GD 39' 102.0000mA 19. (0.41� 001 LLFHB LED,LF,HORNISTROBE,MC,WH,110CD 4W 292.000OmA 19.812 (0.5873V) got S STROBE,EXCEDER 24V MC,WALL,WHITE,1SCD 107 5T 19310 0.0893V) 416-oe ea STW STROBE,EXCEDER 24V MC,WALL,WHITE,15CD Y-0 57.000OnIA 19.9641 (0.0194Vj 002 ST W STROBE,EXCEDER 24V MC,WALL,WHITE,15CD 16 57.00DOMA 19.6 (0T-V) 002 HSWHORNISTROBE,EXCEDER 24V MC,WALL,WHITE,30CD 21 102.0000mA 19.0981 (01126V) na#16-B-141cow 003 STW STROBE,EXCEDER 24V MC,WALL.WHITE,15CD 21'-0 57.0000MA 19. (0.1916V) DD3 STW STROBE,EXCEDER 24V M-C,WALL,WHITE,1SCD 1T-0 57.0000mA 19.5221V (O.15V) 003 STW STROBE,EXCEDER 24V MC,WALL,WHITE,15CD 117 57,000MM 18.9521 (0.146V) 004 LLFHSW LED,LF,HORN/STROBE,MC,WH,110CD 2-0 292.000OmA 19.7554 (0.0171V) 004 HSW HORN/STROBE,EXCEDER 24V,MC,WALL,WHITE,3DCD 21' 102.000OmA 19. (0.1735V) 004 LLFHSW LED,LF,HORWSTROBE,MC,WH,110CD 19' 292.000OmA 18. (0.1628V) LLFHSW LED,LF,HORNISTROBE,MC,WH,110CD 26'-0 292.000OmA 19. (0.1485V) 005 LLFHSW LED,LFi HORN/STROBE,MC,WH,110CD T 292.0000mA 1929M oo5 LLFHS w LED,LF,HORN/STROBE,MC,WH,110CD 4 2922-0000MA 18. (0.02281 O DDS LLFHSW LED,LF,HORN/STROBE,MC,WH,110CD Y-0 292.000D.A 19.8012 (OA0571/) D06 HSW HORNISTROBE,EXCEDER 24V,MC,WALL,WHITE,30CD 19-0 102.000OmA 1921 (0.0838V) 006 LLFHSW LED,LF,HORMSTROSE,MC,WH,IIDCD 14 292-OOOO.A 18.7265V (0.w > C 92'-0 1092.000OmA 007 LLFHSW LED,IF,HORN(STROBE,MC,WH,11000 R 292.0000mA 19.2002 (0.0137V) 176 1092.000OmA Taal Curren:1092.ODOUM 008 STW STROBE,EXCEDER 24V MC,WALL,WHITE,15CD 29' S7.000OmA 19.184_ (0.0162V) Taal Current:1052DOM (Taal VDnap Pement:3.92%) Tota Vaage Drop:0.7988V 160'-0 1251.000OmA (Total VDrop Percem:820%)Total Voltage Drop:1.6735V w m V m 1' Total Current:1251.000DMA Z (Taal VDrop Percerd:5.96%) Total Voltage Drop:1.216V 2#ad6 H D CS l2 0 2O Or W H Q QOJ� _Circuit Calculations Panel:PS Card:00 CircuitSIG4 Circuit Calculations Panel:PS Card:00 Circuit:SIG5 o m z W o Cimu"Mlame:SIG4 Cimud4ame:SIG5 m O LL H 0r dType:Notification Terminal Voltage:20.4V:DC Amperage:3.0000A Circuit Type:Notification Terminal V0lrege:20.4V:DC Amperage:3.0000A Cable:161 4C TWISTED FPLR#16 Cable:16/4C TWISTED FPLR#16 Calculations based on Running Total Length. Calculations based on Running Total Length. U COa Design Criteria'Ambient temperature:167°F Max.operating voltage drop:15% Design Cn na:Ambierntampereture:167'F Malcoperatingvogagedrop:15% Device Part No Appliance Desc Distance Current Voltage Volta a Drop Device Part No Appliance Desc Distance Current Voltage Voltage Drop REVISION RECORD PSN-1000 palm 20AV PSN-1000 Panel 204 DATE/DESCRIPTION OD1 GHLFW 74C RRLOW FREQUENCY,WH 44' 99.4000mA 19.8971V (0.5D2MI Doi GHLFW HORN LOW FREQUENCY,WH 66' 99.4000mA 19.8941V (0.5059V) 002MHT-1224W MINI HORN,WH V-0 22 19.8448 (0.0523V) 002 GHLFW HORN LOW FREQUENCY,WH 13' 99.400U.A 19.8071V (0.087V) 003 HS-24WR HORWSTROBE,2 WIRE,MC,RED,WALL,110CD 21' 186.000DmA 19.6298 (0.2151 003 MHT-1224W MINI HORN,WH X-O 22.0000.A 19.7899V (0.0172V) 004 GHLFW HORN LOW FREQUENCY,WH 11' 99.4000mA 19.5371 (0.092M 004 GHLFW HORN LOW FREQUENCY,WH 3fi' 99.4000 19.591 (0.19821,) GHLFW HORN LOW FREQUENCY,WH Y-0 99.4000mA 19.51 (0.0224V) HT-1224W MINI HORN,WH 3V 220000.A 19.4511 (0.1406V) MHT--1224W MINI HORN,WH 59 22.DWOmA 19.152 (0.3628V) 006 GHLFW HORN LOW FREQUENCY,WH 5-0 99.4000.A 19.42 (0.0216V) SHEET LIST 007 GHLFW HORN LOW FREQUENCY,WH 5' 99.4000.A 19.120 (0.0313V) 00 MHT-1224W MINI HORN,WH 37 22oO00mA 193191V (0-1104V) 008 GHLFW HORN LOW FREQUENCY,WH 3T 99.4000mA 18.9514 (0.1693V) 008 GHLFW HORN LOW FREQUENCY.WH 6-0 99.40OW 19.3034 (0.0157V) FA 0.0 FA DETAILS MHT 1224W MINI HORN,WH 447 22.000OmA 18.752 (0.1987V) 009GHLFW HORN LOW FREQUENCY,WH 3 r-O 99.4000 19.2 (0.0734V) 010 GHLFW HORN LOW FREQUENCY,WH 5' 99.4000mA 18.7322 (0.0205V) 010 GHLFW HORN LOW FREQUENCY,WH I V 99.4003mA 19.2134V (0.0166V) FA 1.0 FIRE ALARM 011 GHLFW HORN LAW FREQUENCY,WH 4TA 99.4000mA 18.600 (0.1315v) 011 MHT-1224W MINI HORN,WH 4' 22. 19.212 .0009V) FA 2.0 RISER/CALCS 01 GHLFW HORN LOW FREQUENCY,WH W 99.4000mA 18.592 (0.008" 244-0753. 01 GHLFW HORN LOW FREQUENCY,WH 26 99.4000mA 18.5623 (0.0297V) Total Current 783.8000mA 01 MHT-1224W MINI HORN,WH T 22. 18.5617V (O.00D810 (Total Vrrop PeMent:5.62%) Total Voltage Drab,1,1675V B 302 1168.6000mA Total Current:1168.6000mA (Total VDrep Percent9.01%) Total Voltage Drop:1.8383V SCALE: 1/8"=1' H LF LF LF LF FHl LF rHI LF LF DATE:1 10/10/16 gq g �g PROJECT NAME LF LF LF LF F-H1 LF LF H LF LF +p D F1 LF Uj Saco Uj 0) W I- C7 nao nao uao ucD � Ixo Q Z LF LF LF Jx Z O A y a < taco 3.D n 5 r Z +srn nao Waco Isco +sct ++ow h oo e- J TI LF b LF b o a < N Pt d 3000 BLDa 1+a0 11aD ItaD +5G0 rSCD 'vim LF LF LF Jx R � TsSHEET DESCRIPTION FA FIRE ALARM IN CALCS/RISER BUILDI SHEET NUMBER FA 2.0 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 FIRE PROTECTION INC. 1730 Gibson Road Everett 98204 425-290-90-9800 INSTALLATION NOTES ONDUIT WITH �g L D G. 1 � \ DAVID MOW 1 CONDUIT ROUTES ARE FOR REFERENCE, EXACT 6x THHN#16 1 x RED,1 x BLACK ROUTE TO BE DETERMINED BY THE ELECTRICIAN. 1 x BLUE,1 x WHITE \ BUILDING LINKING MUST BE DONE AS SHOWN FOR 1 xGREEN 1 xYELLOW \ A CLASS A LOOP AND PROJECT PHASING. 120904, \ \ / LEVEL III p 2)JUNCTION BOXES SHOWN ARE TO BE LOCATED IN THE FIRE SPRINKLER RISER ROOM OF EACH / \ \ BLDG 12 �� �� n BUILDING OR ON THE EXTERIOR WALL OF EACH . SPRINKLER RISER ROOM WITH A MINIMUM OF 16 J \\ \\ 4 f BLDG. 11 _ NFPA AWG WIRE AS SHOWN. JUNCTION BOX LOCATIONS 000sos173 SHOWN ARE BASED ON INDIVIDUAL BUILDING \ ROYL CATS ONDUIT WITH ONDUIT WITH Qaoreo> PLANS. i x THHN#16 x THHN#16 1 x RED 1 x BLACK 1 x RED,1 x BLACK ONDUIT WITH w 1 x BLUE,1 x WHITE 2 X THHN#16 L'1►J BLDG. 14 1XBLUE,IXWHITE 3) BUILDING LINKING CONDUITS/WIRING TO BE RUN 1 x GREEN,1 x YELLOW � 1x GREEN,1xYELLOW �' ,J 2xRED,2xBLAC b�JNFPAyyc TO A GUTTER IN THE ELECTRICAL/MECHANICAL `� \ 2x BLUE,2x WHIT E CFPS ROOM IN BUILDING 17 THE SITE FACP IS LOCATED 2x GREEN,2xYELLOW #1473 IN BUILDING 17). \\ \� / I I I I �& 4 ALL FIRE SPRINKLER RISER ROOMS REQUIRE 1 x ONDUIT WITH I I I CITY OF REbMOND DEDICATED 120VAC 20AMP CIRCUIT FOR EACH \ xTHHN#16 ONDUITWITH - C .,abnswo MO o BLDG. 17 xTHHN#16 1 x RED,1 z BLACK o.#16-B-141 w REMOTE POWER SUPPLY. 1 x DEDICATED 120VAC J- �� 1 x BLUE,1 x WHITE 1 x RED,1 x BLACK 20AMP CIRCUIT IS REQUIRED AT THE MAIN FACP IN \, 1 xGREEN,1 xYELLOW 1 x BLUE,1 x WHITE I 1 1 1 cn Community w 1 x GREEN,1 x YELLOW Q BUILDING 17 ( SEE FIRE ALARM DRAWINGS FOR oNDu1TWITH GEC ROOM II I T. d� w BUILDING FIRE ALARM DETAILS). -ONDUIT WITH xTHHN#16 Building �. _��� W x THHN#16 1 x RED,1 x BLACK G —m W N y w,oVm 'wx 1 x RED,1 x BLACK 1 x BLUE,1 x WHITE y � z#H a C 1 x BLUE,1 x WHITE t x GREEN,1 x YELLOW 1X GREEN,IX YELL OW oo� pS2 -BLD . 15� �� BLDG. 9 2 CI_ FilEXTERIOR OUTDOOR RATED JUNCTION BOX `� \ ® J ,,. _ __ N p o m a ONDUIT WITH __�� 1 a W p W a. x THHN#16 \ _ � , W 3o� a ` W 1 x RED,1 x BLACK N >a o a ELEC.GUTTER TO BE LOCATED IN ELEC RM OF BUILDING 17 \ J w La;; z a 1 x BLUE,1 x WHITE ����_ p O w N M w 1 x GREEN,1 x YELLOW \ g L D G. 10 ONDUIT TH REVISION RECORD \ WI x THHN M6 ^ DATE/DESCRIPTION 1 x RED,1 x BLACK {+� ONDUIT WITH 1 x BLUE,1 x WHITE x THHN ON WITH 1 x GREEN,1 x YEL I x LOW BLDG. 8 1 x RED, x BLACK x THHNHHN#16 r ` 1 x BLUE,1 x WHITE 1 x RED,1 x BLACKSHEET LIST r 1 x GREEN,1 x YELLOW 1 x BLUE,1 x WHITE 1 �.nnnnn�I I ' 1 x GREEN,1 x YELLOW Wuu BLDG. 16 N �� ONDUIT WITH o x THHN#16 B WI!® — 's—� f 1 x RED,1 x BLACK N J 1 x GREEN,1'xYETLLOW B _ BLDG. 5 ; J BLDG. 6, J BLDG. 7 a � N — ONDUIT WITH ONDUIT WITH x THHN#16 tu x THHN#16 1 x RED,1 x BLACK (� = 1 x RED,1 x BLACK _ t x BLUE 1 x WHITE \1 1 x BLUE,1 x WHITE 1 x GREEN,1 x YELLOW DATE: 10/10/16 ONDUITXTHH WITH 1 xGREEN 1 xYELLO e J� PROJECT NAME 2 X THHN#16 a 2 x RED,2 x BLACK 2 x BLUE,2 x WHITE 2 x GREEN,2 x YELLOW ~ LU I W Z Q BLDG. 1 ��BLDG. 2 BLDG. 3_ BLDG. 4 Q Z A Boa p� N ONDUIT WITH ONDUIT WITH d x THHN#16 x THHN#16 t x RED,1 x BLACK 1 x RED,1 x BLACK 1 x BLUE,1 x WHITE 1 x BLUE 1 x WHITE 1 x GREEN 1 xYELLOW 1 x GREEN,1 x YELLOW SHEET DESCRIPTION N FIRE ALARM SITE BUILDING 41 LINKING PLAN SITE BLDG LINKING PLAN E SHEET NUMBER 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 \ FIRE ALARM ` PERMIT APPLICATION �iI1 CK�O Department of Community & Economic Development City of Arlington • 18204 59th Ave NE •WA 98223 • Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO, INCLUDE SPECIFICATION SHEETS,WIRING DIAGRAMS, (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) ✓❑ New Fire Alarm ❑ Fire Alarm Alteration/Addition Project Address: 20201 77THAVE NE BUILDING 9 Parcel ID#: 00829100000103-109 Njmber of Zones lPanels:2 B i d ng Area i,Sq I t;: 7000 Valuation: 3000 Owner: WD ARLINGTON INVESTMENTS Phone Number: 360 6710113 Address: 1020 W CASINO ROAD C ty:EVERETT State: WA Z p Code: 98204 Contact Person:DAVID MOW Phone Number: 425 290 9600 Cell Phone: 425 290 9600 Livia : DAVID@FPISEATTLE.COM Address: 1730 GIBSON ROAD C ty:EVERETT State:WA Z p Code: 98204 Contractor: FIRE PROTECTION INC Phone Number: 425 290 9600 Address: 1730 GIBSON ROAD City: EVERETT State: WA Z p Code:98204 Contractor's License Number: FIREPI*021ML Expiration:7/31/17 Contact Person: DAVID MOW Email: DAVID@FPISEATTLE.COM Electrical Contractor: FIREPI*021ML Phone Number:4252909600 1730 GIBSON ROAD EVERETT WA 98204 Address C ty: State: Zip Code: Contractor's License Number:FIREPI*021ML Expiration:7/31/17 I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described ro wi(1fhP arp nrrian�th the laws,rules and regulations of the State of Washington. 10/24/2016 Applicants Signature Date DAVID MOW Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received WEB Form—130 Page 1 of 1 6/16LP CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT _ Address:20227 77th Avenue NE,#9 Permit#:1189 Parcel#:00829100000103 Valuation:3500.00 OWNER APPLICANT CONTRACTOR Name:WD ARLINGTON INVESTMENT LLC Name:Fire Protection,Inc. Name:FIRE PROTECTION INC Address: 1020 WEST CASINO RD Address:1730 Gibson Road Address: 1730 Gibson Rd City,State Zip:EVERETT,WA 98204 City,State Zip:Everett,WA 98204 City,State Zip:Everett,WA 98204 Phone: Phone:425-290-9600 Phone:425-290-9600 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2015 STORIES: 3 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: 1 OCC LOAD: --lip _A ' PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. [BC 110/IRC 110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the Arlingt n must be reported on your sales tax return form and cod d Cly of ington#3101. 14 1 W Sigilature Print Name f Date Relea By to CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount Total Due: $0.00 Total Payment: $0.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon 9 I 8 I 7 I 6 5 1 4 3 ( zAffir J FIRE PROTECTION INC. 1130 Gibson RDed verett,WA DEVICE INSTALLATION REQUIREMENTSPARK 77 APARTMENTS VICINITY MAP E425-290-9600204 ....IDAVID MOW %%or MWNTW! 3'(MIN) a w NOTPEMIr1ED OVECI -I V A CELND r' , � Iu1R I AuaoPosuu e NSJk0EVCE5 °°1°" RrMIrtO Mu", 12' E`!EL III AX W.M , - BUILDING 9 "ta NFPA D - r•w ra.rP°. [F7_n"_1 sIP DsRO�oOT PSODI,5 Cc1CA7T J aFIRE ALARMOFFICE s m Nr r•rl mAz r FIAt - J.Or STAT•I � +BMAX , t 1 FlNISMED FLOgi ARLINGTON WA I � crrs M 1473 il�Jlfll/ �l�f�llffl�l���� . LITV OF REOMOND DAVID MOW n nan•+. INSTALLATION NOTES n1,16:8•tA, Fire Alarm Symbol Legend 204TH STREET N E 1) Prior to calling for inspection,the installer shall provide srMBa otatrls tnv rMRrMAAlER MFG +r BACABU%REDLgEMENTs MDl%Nr°K NEavo+Ew?�Ts - w documentation to the local AHJ stating that the system has been ANN LCDREMOTE ANNUNCIATOR RAC 7E installed,tested,evaluated and confirmed to be in accordance with all AREA OF WORK w " C governing codes and the approved plans,The Fire Alarm System Ps INTELLIGENT mAMP REMOTE POWER EXPANDER PSNa000 POTTER installer shall complete an NFPA72 Record of Completion(NFPA72 a SPRINKLER TAMPER BY OTHERS BY OTHERS BUILDING 9 w za 10.18.2.1.1). The completed Record of Completion shall be provided to DuauNPurcONracTMoouLF DCM-4 POTTER + eeoxa,smnaam badtox,4 BLOC.t3 0 o u the AHJ inspector at the time of inspection(NFPA72 10 18.2.1.2.4). C o���� PULL STATION SINGLE ACTION P31-IT POTTER t BBOX-2,Smndartl backbux,3 4B•AFF 4p 'c- pU•,� 711 `+ozooa 2) Instructions for the operating,testing and maintenance of the a`00 w�" system,along with record drawings otherwise referred to as S) snDKE.PHoraz-WIRE zw-B syssENsoR 1 eeoz-z,sm"a.ramauo.z \, Om��- "as-built" and equipment s specifications shall be provided at an 1 D6.12 9�DG 11 m z o u~W ( ) P P LFr acc LED,LF.HORNISTROBE,MC,WH LLFHSW WHEELOCK 9 BBOX-0,Stentlerd beckbar,4 STAFF O Wj.� approved location(NFPA72 10.18.2.3). � 1 C w Hi.UG.11 � � ;�.Imn STROBE.EXCEDER 24V WC,WALL WHITE STW WHEELOCK T BBI Standard backbox,2 62'AFF , _ f5u o& 3) All systems and devices shall be installed and tested per the 2 -- manufactures listing and the authority having jurisdiction(NFPA72 �c HORNGTROSE EXCEDER24V M-C,WALL WHITE HI WHEFLOCK 4 BBOx-2. WI,dartlbackbm,2 6TAFF - 3 r—�� — f REVISION RECORD Q' am.17 , 1 I DATE I DESCRIPTION 62 10.14.2.1).Label all device locations containingEOL resistors. 'e ' Co"R"� 8L0(3,9 I ) R��Init � HORN LOW FREQUENCY.WH GHLFlM GENTE% 16 BBO%d SGWnr40KlGat4 'AFF a~ nLDf` 'r 1__ 4)FACP 8 all Remote Power Supplies REQUIRE a DEDICATED 120VAC a 20amp circuit.A notice placed in the FACP shall direct personnel to the �H MINI HORN WH MHr-1224W POTTER 6 BBOx-2,SNntlardb.W-.z 87AFF .._.6 111 -- —^1 .T location of the electrical panel that is supplying DEDICATED power to -� the system(NFPA72,Section 10.5.5.1). The DEDICATED circuit breaker "ao HoawsTRoeE,zwIRE,M-c,RED,wALL HS29WR POTTER + eeox-z.sa.a.a a�wea z BZAFF I gLpg g SHEET LIST FA 0.0 FA DETAILS that serves the fire alarm system shall be Labeled and Secured against 0 wATERFLowswncH BY OTHERS BY OTHERS r,1:;; e I tampering with a RED breaker lockout(NFPA72,Section 10.5.5.2). - __ I 'gU -7 FA 1.0 FIRE ALARM FACP FACP LOCATED IN BUILDING 17 P300 POTTER E BLOC,6 OUTDOOR FDS WEATHERPROOF ENCLOSURE GOELP POTTER i �, I,I.`� I _ - FA 2.0 RISERICALCS 5)This property will have one FACP located in the Community Building. Each residential building will have a Remote Power Supply and a _ B B Remote Fire Alarm Annunciator connected to the main FACP in the Community Building.The FACP will monitor each buildings fire &sprinkler system via SLC,the occupant notification devices in each 7 4- t BLDG.2 _+c r a Z the building will only activated when a fire alarm device from that specific building(waterflow,smoke detector,pull-station) is activated. O to 6) Wall mounted strobes shall be placed 80"minimum to 96"maximum F-I Z LLI °C SITE PHASING PLAN - - above floor level.(NFPA72 18.5.4.1 8 2).Will mounted strobes shall be SYSTEM cw °uTs m(� sized in accordance with(NFPA72 Table 18.5.4.3.1(a).Ceiling mounted R.4uu.d FM.s.1.1y C..ojeluA+ strobes shall be placed and sized in accordance with(NFPA72 Table c,vdu.nan M Non / 0 18 5 4 3.1(b). �/! / \�, } 1-W a SCALE:116"=1' 7) When MORE than two notification appliances are visible at the same ,� yT a O Q 0 Z DATE: 10110/16 time whether they are in the same room or adjacent space within the u i field of view,the flash of those strobes shall be synchronized(NFPA72, g - TF{t w N d - PROJECT NAME Section 18.5.4 3.2(3)8(4). Fp3o Q � r- C7 ` Z Z CIRCUIT LINE TYPE Circuit Legend 8) Pull stations shall be placed between 42 and 48 inches above floor . ~ .R 3 F is>/ i•+^f Z_ _ 0 Abbreviation T e Name Z Z Q level.Devices shall be red in color(IOC A117.1 309 8 NFPA 72 17.14.5) E � ��g'a� ® I0 V W J ____ u U #1B/4 FPLR SLCSIGNAL LINE CRKT W W 3 d`r 5 J J - —� p #1614 FPLR TWISTED PAIR NAC-NOTIFICATION CRKT � 9) Outdoor strobes required for approaching Emergency Vehicles to §� g s " t� �. 0 Z " ~ Z Q Z be located in the upper 25%of the building(at a serviceable height), r '`Y°`m g a I_ Z�m a B #1B/4 FPLR SBUS Q Z _ and to be clearly visible from the emergency vehicle approach path., p� 1 m w11 - - Q A A r.rr .-r- r Z 10)Fire Alarm circuits to be installed/secured/terminated in accordance SYSTEM INPUTS A O C D E F o N I J ~ Q r m J with NEC,NFPA 72,IFC and Local AHJ requirements 8 standards. +TIA.ZA to.Alnm9m.. • • • •• + v a 7 S.M.I IKYY. • • • •• 1 N r w 1.,Pm. • • •••• � Fire Alarm Device Numbering 11)The means of communication to the central stations for the fire e.4 S&1nMMM Cnnl lAM • • J (SLC)ADDRESSABLEDENCES NOTNRGATION DEVICES a alarm system is to be provided by a Potter UD-1000 DACT as per plan. s -AM—AG III F.dur. ♦ • s System requires 2 x POTS telephone lines,1 of these lines is required F FInAWmSF.1.InLo IM. " • • • +%` c Tcu to be DEDICATED to the FACP.The FACP is located in building 17. r oM"uNm1 • • t ^ `► ��oFVICEAODREss -o DEIICE n n lueund Faun • • ! Received SHEET DESCRIPTION 12)All building linking conduit 8 wiring to be provided/installed by + NAtwc.ImoAnnnAc.cNemtsw+ • • + SLc_"# others. to R`m°e—a°`2.4 I vwu` • • +o (S) ' 1 � FIRE ALARM A B C D E F B N 1 J q OCT 2 Z01� ws aCD DETAILS OPERATIONAL MATRIX l,� GU SMOKE DEFECTOR SHOWN EXAMPLE SHEET NUMBER FA 0.0 9 I 8 I 7 4 3 2 t 6 5 9 8 7 6 5 4 3 2 1 FIRE PROTECRON INC. 1730 C,ba Road EYere#,WA,98204 425-290-9600 DAVIDDMMOW �M1C.SL�. 120904 LEVELAL- D D UNIT B-11 NFPA ouueoslva aaa+a i UNIT B-10 r-- UNIT 8-12 A UNIT B-9 � i :--I� �'P�—F\� � � I 1•-J0p OvBIN-Ali1�Eklfio�fl � Lam, I 1'o------'--_ _ I 1 �'• NFPA 1 C------ crvs ` I I I fTa�a I I I I I I 1 I I A I I J Cm oo eEbLwNo I ------------- 1 STWR 1 I STAIR! I I I Yte B-Ift T.— ENTRY ��I-- I ENTRYCN g2„ � rn C 1 �m C _ z ;mQU s 1.- CI.0 — C, p Qsw�LL omm, ° 3RD FLOOR Zlu�m&a V mm�aLL N REVISION RECORD DATE I DESCRIPTION Tmw .^ NIeA LDLR- Rlel.T/IHN S!. TO THE FRCP T - I LOCATEbi_r DiI-Nc» SHEET LIST J FA0.0 FA DETAILS -------- 1— �-- . 1—� $ FA 1.0 FIRE ALARM 1 "IF FA 2.0 RISERICALCS 1 I I UNIT BA UNIT Ba 1 B I UNIT A T Type A YP0 A 1 I eoa UNIT BI � Fs ` UNIT B-6 C{'y UNIT 11-1 I — B UNIT Bs..�.. TypeA I UNIT � ea.,u 1 U!,--------------1 ---il0s,. 1 Type - H----- - 1 1 IA-J"• I ----- ---f--- ; � i� i I -- R16N FPLR e104 I i' I I Y6�lFi{6S'Elf IFOOAI_' ti 0-INiF�sE"R_ I 1 I I 1 I •00JO I 1 I L I ,, 1 I I I I SCALE:118"=1' DATE: 10/10116 I I I I r-——————— I I 1 I fo' I - I - - PROJECT NAME ❑ 1 -?----- ISTAIR/ STAIR/ � � eTAFb �_ ( ENTRYI ENTRY EN7/"1Y j x..ea I 1 l I N u ENTRY ( ( I I p ,. NN y„ ILU • -- lA 1 I Z Z ...� I I a. Z Q Z 0t---.,f. ,y 1 I I Q = 0 Z A o Q w UP Q 1STFLOOR � 2NDFLOOR* a N N SHEET DESCRIPTION FIRE ALARM SHEET NUMBER FA 1 .0 9 8 7 6 5 4 3 2 1 i i AR'E.PROTECTFONiNC. 1730 Gibson Road Everett,WA 98204 425-290-9600 Battery Calculations for Panel:PS BUILDING 09 DAVID MOW IanNapsR.i .Drt[um'3'--ae:�rriur o Hailnl¢--v6Cvcr�a�rio6H- --— Pan No ty _DDsmipuon Atelln_Tdd Alarm oo w"E�aMM To toALiip,7WERvol reaaoamA 75 n60000mA 2n6nooalN r6olpoow � P.L., _ _ rtlY Rrwldpr �00001M T' �IAIr+INrm .15 „ -. 161110",PROM2uARE-6- "-1 v 001 --- D LEVEL III --_.. 19/•1 1 POLLSTAT10NSa1GLEACT16H o000omN 8(100rAnA' 000UomA 00ub6nAl LLFHSW'. LED LF.HORNISTROBE,MC WH INobficalionl DWWW DOOOOmA' 21120000mA 2820 SrNOBF.00EDER24VNC.WALL,WHITE P11MItafa�-_-_ ___ODDOaN 0.06bbmAI 57A000nM-3iD 0000mA D �lllltlM5TR00C,C)4CEGER'MC.IIYMLYM�iE�� 0 0.0000mA1-- t0o.000OnA.4aaaga.A ` I HLFW 1 HORN Law FREOW4"W"PUWWMN 0 0000"IN 00000m11i 994000mA 15eo400omA*f Mn•1 WN IiDH1R,WM{NFIanaFN 000a A 00000m 1 22 a0oDmA 176 0000rnAl 1 HHW1177gO6E,7WRE.MC.REO.WALLo/NfirafioN 00000mA 00000mFi tab o0o0mn 1680U U D �To IP tlPh ISW OO OOmA malPenpnAmm S7:i1KOWA. NFPA elFIIA AA a 7�TarAIWrM +-sooeDDwaA1� Sbmdby lima 24 Hrs 1BAhl O Alarm Bme:S WII 0467M �A,QA0Tte4p4 EZy qui-1, 2260M Compensmion Factors-Sp :12 Ala-12 ReeutremeMw9h rom nsafion: 2721M} y,�FIPPA yx VV CFIS Circuit Calculations Panel:PS Card:00 CircuitSlG1 Circuit Calculations Panel:PS Card:OD Circuit:SIG2 Circuit Calculations Panel:PS Card:00 Circuit SIG3 aJ473 o"Cole—so' C-06mo a1a7 CimuilName:SIG3 Circu4Typm:NW—fl.n Terminal V0a,,,20AVDC Amperage3WWA Circuit Type:NOifire0on Terminol Vnitege204V:DC Ampemge:30000A Q..h Tylm:NofirF.ation T Inal%k&W,:2o4VDC Am,mmite:30000A Cable 16'4CTWISTEDFPLRk16 Cable'16 4C TWISTED FPLR etfi Cade 1614C1 WI6TED FPLRp16 Czlcmahons b.—I-Rumning Total Length IW4 Calculationsb d on Runnng Toml Length Calculations Weed en Running Teml Length :._ T-..-�11P -L T 4 ,. _ 'Va. 9__P- Deafen Cn7eAa:Amdenl lemomalure:167•F Max opemlNg vdmgTtlmp 15% _ GM -AMWW'1W.A-%.167-F M 15% C,Mtla IATF&U.a Far dmG laT1 DW400 Part No_ an1:eDDa, O�torwel Current VoIHIpOVoltageD10p' OoVI*PWNo• Appwn=Dw DifiLn,e Conant VoltaaDro D�Y1calPan110 AppllorlceDes. DIfi1811Cei CuRrwD Villa VnIIaOeDrop by T Oe . OF etEOA101R0 Pswoao Pend 2o4J_ wwMow S iR446V W EH24VM2iV. I.WMrE,If,OD 2 37000aM HIlit 1 0o2P5N•t f7nY 20 —_.- o.emeeowasa w 1 h11M 1— T 20 �•� ---�- _ -.. _ LLFHM LED.LF HORWSTR24V MC WH TIMID WHI 46'-01 257 faAl2 8E ASW STROBE,E%CEOER 24V M-Ct WALL WHIFE.ISCD I 102' S70Wg 1rr 451 1 ft OaL�VJ � ST STROBE EXCEDER 24V M-C,WALL WHITE 15C0 _ 15'-0I 570000mA ID Ie1V1'. HSW HOrtN5TR0 FJ(CEDER AV.MC,WALL WHITE 30GD 21'4 M Is 098111 f02128VF 91a49141 .—OaT 6S M -CERtNIM1C 1VIAtC WHIM 10CD 2000 21•g 10a. f97 fa1N 003 SW STROBE E%CEDER 24V M-C._WPLL WHITE,I5CA 17'-0 57000o HI.a2'!1 .IDr) E1WR.STROBL LycgmR Mul— L,WHITE.I5CD 16'-0 ST0000 189521VI (a146W AHD IF, ODE.MCyWN.IIOCD 2-0�70T lav /D0 004, HS HOID4M&[EEIOCEDER MIC,WALL,WHITE,3 b - 21'-0�1o200a0 ta- e0.77YlYI' 00 LLFHSW'LED,LF,F!MNSTROBE,IAC,WM,110CD l9'-0'[92W0r1 i6 a06�LLF .IlORNE1R09E.MC,w LI�T10CID z6-0t 2g0 to .. W./4a011f 605 LLFHSW LED.LFHGRNISTROBEMC,WH,110CD T-0 zsl 1 L►FN6Rr LEO,LF_HOFMSTRORE.MO_WM,1tarD 4' 712 to IDIOM) p 00!LLFHS (®.LF.-li'ORlOL1RaDE W,WRLnDCD 242D2 _ 9iDT q-0 Fh gW HSW HORWSTROBL EXCEDER 24V,MC,WALL WHITE,3DCD _ 18-0 l02 - LD2 _ 11FHDPA LEa•if-NDRNITROK,MC•WN 11DDD - +4_, ???-_._.�!•-- -- > aZ-0�IDa2 007 LLFHSW LED,LF,HORWSTROBE,MG,WH,110CD 4-0 2922 MM /D b _ _ r7f t0a2 TrealCelrMF'40a2000ant1 =pjwn m C 741MISFHM'1010 DODOm4 OOB: aTVJ STROBE,E_X_CEDER24VMC.WALL.WHITE,15C6 75-0I 5i 00162V� m V m m rTaIY WIOpPOImM19lDI TalN tkRlae OVP'07oaaY t674Y,1}':1 l7 fYmmeaYo%)ToIaIVRaaq aFP:19'�V U'z . 111. T4W OuI,Ma f201.0a00m111 z"ti u I- (TaRYt�WiAN_'J-.�11 IeW�Gap:tal4V� �.[u = DD � \� �OJ�l7� p0>�NJ >OCOw4 Circuit Calculations Panel:PS Card:00 Circuit:SIGS m rc F o Circuit Calculations Panel:PS Card:00 Circuit SIG4 >u O u y> CKu4lRsme SIW — c"uiw—v sw m ty W�Q1 rc CircuA Typo:No�cafion Terminal V,11nN:204V:DC Amperage:30000A C1muRTyW Nelil won T inal Voldge:204VAC AmpemW:30DOOA CFH4 10 4C TWMIDD FIRR eta Cede:16 i 4C TWISTED FPLR i16 t Fu y1 b&a C+k,+tb...a former Htmraq immLAMA C*ItWMu Wale enR—V TOW La%V,. oVKa aI� ddpn GRM.N An40.eNean�oera4n'.q7•P No.IlparaYgvaaapstl'ep 15% f ah AA1YW mtir4187'f 1W 8Fe'15% °R" REVISION RECORD �D*VWO Part No � Apphome Des,, Diatana Current Volul Voltage Dr011. DedOe Pan ND_ Appoomoo 0esa Dbtanae C40mm V070 Vor ape Drop PSBR 1006 Poem 20 P6b4I_PxW- _ 2D __ _ _ am Wa. HORN LOW FRe0VE11Cl:VM DP../D_ D 1 ID - DATE/DESCRIPTION Got,, 00.F1N HMN LONFREDDENCY NM 4a aa40W.Al� — -- H01MIlAW flIL01lIEN4 M� lY a0 4 7 m 1 OODMNT.127 faM1gRN WN _S 22 la.. ' HORN LONFREOIIE .-_.F312 — T.1Y,t�4W MIMH0101 WN 7 22 to. 001 HS-24WH FCRIiSTROOE 2WRE.YC-RE41'NICO 1Y 1o6000aM19. 2167 oO GHLFW1 LQI9rt1E0+1[NCY.'1V11 11 —S III _D� AdOOMMA 1a 1 , _ 00. cHLFw*HOWIL—ON!pREO1,ENCYYAI S-._So.-�-_ Iasi r.I hMaLglill wH 10 q�1' 101�09M1QSAHT-1224W UMHMN VM ar 22 lei +a�R/�ai."!Fr�n�oYWN " SHEET LIST GHLFWI/OIDILOVVVFREOIEMY 9 Da�101 t 00. 1 A10a110W1W/1 ta21D1. 11!! P FA 0.0 FA DETAILS allGHLFW RoRRLOW(REOILIENCy:tWH 1Y N400aM1aD614J .tO.agIO , RIRLRFRE01llNOY yM0ta7Y�.-- FA I.0 FIRE ALARM W GHLFW NOMLOWFRE00EgC1yW" 6 DD4 to 7J2 0206Y Ot -__HORNLOW FREOUENCR. /on GHLFW on�•77NIA11/111N1111G11 N?1 FA2A RISERICALCS .. �- I�OPIiIdN— iNC1;WN A}' 00a 141)15W IA B 01 NORNLONIFREOLIfNC�,WM_,� — _ 4 09-' ,14'�- N, '!) Tdm C--d lwu000"A� -bi �HLFVF IIGN�IIA YFPlOUENCY ItlH ]Y a fe a 1 HT.1224 .yM 3' I�IaE6t.. P000a�V — gr40FyD1oPPettele6a2%1 raM VNmpe Dto►:1 tallow W2' 1IOa ' TwaaAaert am+riilul (Fina1 VDrap Pllt6"1IR U T00V WWDW IXXN SCALE:1/8"=1' DATE 10110116 PROJECT NAME ®Ju lF V L�F lI :r:F tjr IF IF U) LU Z a � C2W� a4v mace .Io:a •1cn r ace Ix a Z Cq F s ao�� A } 1 of If >; QJ_ n(7+ �' X 8 s n =)Il--Z nm�J 11CO 1as „eo n1a C IY N PS a N a •' BLDG 09 SHEET DESCRIPTION ip FACP a FIRE ALARM t IN f CALCS 1 RISER BUILDING 17 A/Tt] SHEET NUMBER FA 2.0 9 8 7 6 5 4 3 F 2 1 f_ ___I ?i / FIRE PROTECTION INC. Everett.WA 98204 425-290-90.9600 INSTALLATION NOTES _ "� _ L I t---i -`� 'I DAVID MOW aNDurr w1TH _ - 1)CONDUIT ROUTES ARE FOR REFERENCE EXACT 6"TMHiu��6 - 1,;--BLDG. 13 e 1 x RED,I x BLACK ROUTE TO BE DETERMINED BY THE ELECTRICIAN. 1 x BLUE,1 x WHITE BUILDING LINKING MUST BE DONE AS SHOWN FOR 1 xGREEN,1 x YELLOW Z �- i r / r J' j l 1 120904 A CLASS A LOOP AND PROJECT PHASING. _ LEVEL 01 0 2)JUNCTION BOXES SHOWN ARE TO BE LOCATED 1 IN THE FIRE SPRINKLER RISER ROOM OF EACH BLDG. 12 BUILDING OR ON THE EXTERIOR WALL OF EACH NFPA SPRINKLER RISER ROOM WITH A MINIMUM OF 16 j,- ! J BLDG. 11 AWG WIRE AS SHOWN.JUNCTION BOX LOCATIONS :. / / f I y------­r- 1 SHOWN ARE BASED ON INDIVIDUAL BUILDING Rovl.cera PLAN$. b xNHHrT r+v6 H / CONDUIT WITH , i / I.' _ 1 �Qaorecpo 8xWHN$16 f I.RED,1,.BLACK •', 1 x RED,1 x BLACK CONDUIT WITH ( I IxBLUE ,x�'JHITE `BBLDG. 14. 1xBLUE IxWHITE—�I '12_X THHN M,B �n 3)BUILDING LINKING CONDUITS/WIRING TO BE RUN I.GREEN 1.YELLOW C 1 x GREEN,t x YELLO , ,f 2%RED 2 x BLACK_ -- TO A GUTTER IN THE ELECTRICAL/MECHANICAL ;� I sxGREE xwHiTe ` � - � 2 x GREEN,2 x VE_LLOW ROOM IN BUILDING 17(THE SITE FACP IS LOCATED 1 t 1 1 IN BUILDING 17). 4)ALL FIRE SPRINKLER RISER ROOMS REQUIRE 1 x \ / L CONDUIT WITH cirv�o eoMw o / 6% DEDICATED 120VAC 20AMP CIRCUIT FOR EACH THHN Nib / `B L L G. 1 7 /x RED.I x BLACK x _ REMOTE POWER SUPPLY.1 x DEDICATED 120VAC / 1 x BLUE.1 x WHITE x x 20AMP CIRCUIT IS REQUIRED AT THE MAIN FACP IN / J ` f C o rr m u n ity,x GREEN 1 x.YELLOW x BR N 7 x BUILDING 17(SEE FIRE ALARM DRAWINGS FOR GUTTER IN C BUILDING FIRE ALARM DETAILS). coraoulT wl EC ROOM j cONouITWITH / � ti IR.,, n5 Buildin _ aZ 6xTHHNn16 • c IxRID,IxULAC g G 1 I ymu9 it C 1 x RCLI 1<BLACK _ 1 x BLUE,I x WHITE - a i R ULUE,I x WHITE 1 x GREEN i x YELLOV.' I�- - 1 0$u 1 x GREEN,1 x YELLOWI ,BLDG. 15 _ _ - I'� _ o>o0, � BLDG. 9 I _ _ _- go�oo - CV o s u LL Fil EXTERIOR OUTDOOR RATED JUNCTION BOX / I �1 .' ++ _ I m.2"r OgaoulI%V1Ili { o�uW 6x THHN+16 -`. / M��l++ - 1 W /© 1 x RED.1 x BLACK ELEC.GUTTER TO BE LOCATED IN ELEC RM OF BUILDING 17 ( - 1 ,1 x BLUE.1 x WHITE +d J rd 1 1 x GREEN,1 x YELLOW_, BLDG. 1 O ++r 1 r` 1 REVISION RECORD / ++-+,�+++ CONDUIT WITH C16. DATE I DESCRfPT10N ++ \ G.a THHN N18 � --�y 4 . 1 Jr _ - 1 1 +.%+++ 1 x RED 1 x BLACK�'� 1 I CONDUIT WITHf _ r �r- 1 x BLUE,1 x W_ HITE 6 x TI IIN A16 ICONOUIT WITH 1 x GREEN,1 z YELLOW_ ?(1S I x RED.1 xBLACK �ax THHN Nth BLDG. V -- I I x BLUE 1 x NINITE• J 1 x RED,1 x BLACK - _ 11 SHEET LIST 1 xGREEN.1 x YELLOW I 1 x BLUE,1 x WHITE 1 1 rfI 1 x GREEN,1 z YELLOW r-�B L D G. 1 6- - _ '�.�_� - -" ,- QNUUIT WITH — __ i THMN 016 B - JI - -i -- �� f , 1 x RED,1 x BLACK a _ �� ;- -- J-BLDG. 5 J BLDG. 6 J BLDG. 7) 1x6LREEN WHITE w1 I_ B j I I -TM I I }"1. I �jTMTFONDUIT I\� Nb�TtITWNiTIH _xTE _ z THNN M16 —1 x RED ,x I (A - i x R D 1 x BLACK 1 z BLUE 1 x 1 `1 1 xGREEN 1 x DATE: 10/10/16 BLUE 1 x WHITE I T 1 ` CONDUIT I I l x T.xGRE_i,_1�x_�YELLOW} `—� I I LI ! PROJECT NAME y -�,Iq I 1 X THHN N16LU _ a �� �xRE02xBLACK --_ _ ` 2 z BLUE,2 x WHITE �- I�, () - 11. W- !4 _2 x GREEN_,2 x YELLOW• ( BLDG., 'i PI _ BLDG. 3 BLDG. 'P =-`'1 I W =o 1 - BLDG. 2 ,r LU a Z A IL J ONDU11 WITH ONDUIT WITH 1� a x THHN A _ x THHN 616 IX RED,7 x BLACK 1 t x-1EW,,x BLACK t x BLUE,1 x WHITE 1 x BLUE,i x:WHITE 1 x GREEN t x YELLOW! I x GREEN,1 x YELLOW SHEET DESCRIPTION N FIRE ALARM f BUILDINGSITE LINKING PLAN E SHEET NUMBER a PLAN- 9 18 1 7 1 6 1 5 1 4 1 3 1 2 1 1 CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 _1 PHONE; (360)403-3551 BUILDING PERMIT Address:20227 77th Avenue NE,#9 Permit#: 1189 Parcel#:00829100000103 Valuation:3500.00 OWNER APPLICANT CONTRACTOR Name:WD ARLINGTON INVESTMENT LLC Name:Fire Protection,Inc. Name:FIRE PROTECTION INC Address: 1020 WEST CASINO RD Address:1730 Gibson Road Address: 1730 Gibson Rd City,State Zip:EVERETT,WA 98204 City,State Zip:Everett,WA 98204 City,State Zip:Everett,WA 98204 Phone: Phone:425-290-9600 Phone:425-290-9600 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP L[C#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2015 STORIES: 3 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: ] OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the .y fArlingt n must be reported on your sales tax return form and cod cad C'ty of A ington#3101. lee Sig lalure Print Name Date Relea By Dak CONDITIONS Adhere to approved plans. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount Total Due: $0.00 Total Payment: $0 00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit Information Date 10/24/2016 Permit Number 1189 Project Name Park 77 Applicant Name Fire Protection,Inc. Applicant Address 1730 Gibson Road City, State, Zip Everett,WA 98204 Contact David Mow Phone 425-290-9600 Email david@fpiseattle.com Permit Type Fire Alarm Site Address 20227 77th Avenue NE,#9 Valuation 3500.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use Apartments Assigned To Launa Peterson Property • • Owner Information Parcel#:00829100000103 PARK 77 LLC PARK 77 LLC 1191 SECOND AVE STE 1901 20227 77th Avenue NE SEATTLE,WA 98101 Contractors ContractorContractor Name Primary Contact Phone Email Type License License# IRE PROTECTION INC pavid Mow 25-290-9600 pdavid@fplseattle.com 17ONTRACTOR abor and Industries IREPI-021 ML Review Date ype Description Target Date Completed Date Assigned To Status 10/24/2016 eire Alarm 11/7/2016 1 revin Olander In Review UploadedUpload File Date File Uploaded By 10/24/2016 2:32:01 PM a9 Fire Specs Part1. df lReterson, Launa �. 10/24/2016 2:32:01 PM 4 Fire Alarm Permit Application C ZBBm Tlbzl<ON. df Peterson,Launa , 10/24/2016 2:32:01 PM 149 Fire S ecs Part?. df Peterson.Launa y: ,: } crt •L � i I 4sc; `' FIRE ALARM PERMIT APPLICATION t Department of Community &Economic Development City of Arlington• 18204 59th Ave NE •WA 98223• Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO,INCLUDE SPECIFICATION SHEETS,WIRING DIAGRAMS, (POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) ✓0 New Fire Alarm Fire Alarm Alteration/Addition Project Address: 20201 77THAVE NE BUILDING 9 00829100000103-109 Parcel ID#: Number of Zones/Panels:2 Building Area(Sci Ft) 7000 Valuation: 3000 Owner: WD ARLINGTON INVESTMENTS Phone Number: 360 6710113 Address 1020 W CASINO ROAD City:EVERETT State: WA Zip Code:98204 Contact Person:DAVID MOW Phone Number:425 290 9600 Cell Phone: 425 290 9600 Email: DAVID@FPISEATrLE.COM Address: 1730 GIBSON ROAD City:EVERET17 State:W4 Zip Code: 98204 Contractor: FIRE PROTEC-nON INC Phone Number: 425 290 9600 Address: 1730 GIBSON ROAD EVERETT WA 98204 City: State: Zip Code: Contractor's License Number:FIREPI*021ML_ Expiration:7/31/17 Contact Person: DAVID MOW Email: DAVID@FPISEATn E.COM Electrical Con8a�tor: FIREPI*021ML Phone Number:4252909600 1730 GIBSON ROAD EVERETT WA 98204 Address: City: State: Zip Code: Contractor's License Number:FIREPI*021ML Expiration.7/31/17 1 hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property W!!hA ate.nrr+ance with the laws,rules and regulations of the State of Washington. 10/24/2016 Applicants Signature Date DAVID MOW Print Applicants Name FOR STAFF USE ONLY OCT 2 4 2016 Permit# Accepted By Amount Received Receipt# Date Received WEB Form—130 Page 1 of 1 6/16LP FIRE PROTECTION, INC. PO e0X 12642 MILL CREEK,WA 98082 (4251 290-9600 OR 1-6004814125 FAX 142513534546 OCleher 20,2016 City of ARLINGTON - PLAN REVIEW RE; FIRE ALARM SYSTEM Please find enclosed plans for a FIRE ALARM SYSTEM.The FACP will be located in building 17 ( lower floor of this building is the site community building) , all residential buildings will have their own individual fire alarm annunciator and remote power supply. All residential buildings sprinkler systems will be tied to and monitored by the FACP located in building 17 . The site electricians (Express Electric) are providing building linking conduit/wiring as shown on the included site building linking plan. The SLC and SBUS will be run in a Class A loop as shown. When a Waterflow, Smoke Detector or Pull-station is activated in a residential building, it will annunciate at the annunciator in that specific building and also at the FACP located in building 17. Residential building occupant notification devices will only activate when an initiating device in that building is triggered, no other building' s occupant notification devices will active. The system has been designed per NFPA 72, 2013 edition requirements as well as WAC, IBC, IFC 2012, NEC current and your additional requirements. The building is fully-sprinkled. The system shall monitor by zone activation as well as separate trouble signals. Monitoring shall be provided via UL listed Central Station, The Alarm Center LACEY, WA. Audibility shall be in compliance with NFPA standards. Interior DB shall be 75 DB minimum throughout, (LOW FREQUECNY NOTIFICATION DEVICES TO BE INSTALLED IN RESIDENTAL SLEEPING AREAS. A full service and monitoring agreement is in force for the proper service and maintenance per NFPA requirements. A full pre-test and NFPA form shall be conducted and completed prior to calling the AHJ for acceptance testing. INSTALLATION COMPANY Fire Protection, Inc. 1730 Gibson Rd. Everett, WA 98204 WSCL# FIREPI*021ML UL CERT #608242-002 JOB SITE Park 77 Apartments *Building 9* 20201 77 th Ave Ne Arlington, WA Received OCT 2 4 2016 APPROVED UL MONITORING COMPANY Alarm Center, Inc./FPI 4300 3rd Ave. SE Lacey, WA 800-429-0991 UL CERT #902799-02 CONTRACTUAL RESPONSIBLE PARTIES Installation; Monitoring; Service; Testing; Fire Protection, Inc. AMBIENT TEMPERATURES No area with alarm service equipment shall fall below 40 degrees, common areas shall be at 68 degrees per builder AMBIENT NOISE RANGE All areas serviced by the Fire Alarm Control and notification system will be as listed for per UBC listings, per builder. SEQUENCE OF OPERATIONS All Alarm and Trouble conditions shall enunciate at FACP as well as remote notify UL listed Central Station. Zones of alarm shall cause for all notification circuits to activate, send alarm zone to CS, re-dispatch to Fire and dispatch FPI runner service. Trouble and supervisory signals shall transmit to CS which will dispatch FPI runner service to site, (no notification circuits shall activate. ) On site emergency contact personnel shall be notified. Wet Waterflow ALARMS shall be retarded by a period of not more than 45 seconds. Low air shall activate at 251bs, causing for a supervisory signal. A short on FACP smoke, Waterflow Switches, (wet and dry) and pull station shall cause a alarm. Shorts on PIV, tamper and Hi-low air zones shall cause a Supervisory condition. Opens on any zones shall cause for a trouble signal. Should you have any further questions, please feel free to contact me directly. David Mow VP of Operations/Designer NICET-3 #120904 CITY OF REDMOND D.O.R. #16-B-141 WA JOURNEYMAN LICENSE #MOW**DDE957M6 FACP FOR ALL BUT7,DINGS LOCATED 7-1 BUILDING 17 @POTTER P300 P/US J Fire Alarm Control Panel Features • 127 expandable to 381 Analog Addressable Points.Any combination of detectors/modules • 5 Amp Power Supply.Expandable to 315 amps • 2 NAC circuits rated at 3 amps maximum,expandable to 188. • 2 Input/Output(I/O)Circuits for system flexibility rated at 1 Amp each • Built-in UL Listed IP Communicator • Built-in email event notification and report capability. • Optional Dual Line Digital Alarm Communicator • System wide synchronization of Potter/AMSECO,Gentex, Cooper/Wheelock,and System Sensor signals. • No twisted or shielded wiring required. • Cabinet will accommodate up to 18AH batteries.Panel will charge up to 55AH. • Capable of Class A or Class B wiring configurations • Built-in NFPA 72 compliant smoke detector sensitivity test • Dead-front cabinet design • 1000 Event History Buffer U` y, NYC Fire Dept. - Certificate of Approval Pottsr/Nohmi Protocol Features S735 7165-0328:0195 6156 • Less than 4 second polling time Product includes a S year warranty • LED's visible from 360' • Adjustable Smoke Detector Sensitivity • Adjustable Heat Detector Temperature annunciators,intelligent power supplies and other optional modules. • High Temperature Heat Detector as fixed temp The P-Link will support 31 accessories in any combination.The RA- Drift6075 is a 2 x 16 LCD annunciator.The RA-6500 offers a larger 4 x • Compensation 40 line LCD display that allows points and descriptions to be shown • Maintenance Alerts simultaneously.Intelligent remote power supplies repeat the P-Link data • Day/Night Mode and can be mounted 6,500 feet from reach other.P-Link devices such as the RLY 5 relay module,SPG-1000 serial parallel gateway and DRY 50 O e s c r i pt i o n LED driver can be mounted anywhere in the chain of communication with a maximum of 31 of each P-Link devices.A total of two(2) The P300 is a mid-sized analog/addressable fire alarm control panel SLCE-127 Signaling Line Circuit Expanders(loop cards)may be with a total of 381 points.The points may be any combination of smoke installed in the P300 enclosure,in a remote enclosure such as the AE-8 sensors,heat detectors or modules.This panel has a 5 amp power supply or with a PSN-1000E remote intelligent power supply. that is distributed across two Notification Appliance Circuits(NACs) and two Input/Output(I/O)Circuits. The entire system,including the SLC,NACs and P-Link may be converted with a CA-6075 Class A module.The entire system is The NAC circuits are rated at a maximum of 3 Amps each and the 1/0 programmed using a Windows based computer software and requires circuits are rated for a maximum of 1 Amp each.All of the outputs may the use of a software programming software key. be configured for notification or auxiliary power.In addition,each NAC and Output can be programmed for strobe synchronization and utilizes The P300 can communicate to a monitoring station using the on board Quadrasync for strobe synchronization across circuits of various brands. Ethernet connection to an IP communicator or using optional UL listed The I/O may also be programmed for a dry contact input such as a water UD-1000 traditional two line alarm communicator.The UD-1000 flow switch or pull station. connects to the main board and has two phone line jacks provided. The IP communicator uses a RJ-45 connection and when connected The cabinet will hold two 12 volt,8 amp/hour batteries or two 12 volt, to the internet may be programmed to E-mail system status,history 18 amp/hour batteries.The system when fully loaded will charge 55 reports,reminders and the configuration file.The panel may be updated amp/hour batteries.Anything larger than 18 amp/hour will require an remotely using the UD-1000.If the Ethernet connection is needed external battery cabinet the SSU-00050. remotely,the FCB-1000 fire communication bridge may be installed to The panel has the Potter P-Link connection for expansion with remote allow the Ethernet connection to be installed in a rack. Potter Electric Signal Company,LLC • St.Louis,MO ©P07TrO 800-325-3936 • wwwpottersignal.com P/US' #8830035-REV A PAGE 1 OF 4 08/12 P POTTER P 0 0 0 e PLUS J Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 381 addressable devices or modules in any combination.The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PSA Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PSHA Combination Analog Photo Electric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135'Fahrenheit heat detector FHA Analog Fixed Temperature Heat Detector that is selectable from 135D F to 1850F RHA Analog Rate or Rise Heat Detector that has a fixed temperature selection from 135°F and 174°F and also will alarm if the temperature increase 12-15°F in one minute ODA Addressahle Duct Smoke Detector AB-6 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors AB-4 4"round base that may be mounted to an electrical box and wired for connection to the above sensors AIB Isolater base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop ARB Addressable Relay Base that contains two relays controlled by the SLC.One relay is rated at 8 amps at 240 VAC/30VDC and the other is rated at 2 amps 240 VAC/30 VDC ASB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call. Modules Device Description MCM Miniature Contact Module provides a small foot print contact module for mounting inside an enclosure. APS-SA Single Action Addressable Pull Station APS-DA Dual Action Addressable Pull Station SCM-4 Single Contact Module is a standard contact module with an LED that mounts into a 4"square electrical box. DCM-4 Dual Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. TRM-4 Twin Relay Module provides two form C relays that simultaneously active when the module is triggered by the control panel. Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC. MOM4 Monitored Output Module is a power switching module that monitors the circuit that is controlled by the control panel. CIZM4 Conventional Input Zone Module is used to connect conventional smoke detectors to the system that receive their power from the module.This module is like a conventional zone on the SLC. SCI Short Circuit Isolater interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. Potter Electric Signal Company,LLC • St.Louis,MO P �i 800-325-3936 • www.pottersignal.com ��s! #8830035-REV A PAGE 2 OF 4 08/12 P POTTER P300 P/US J Fire Alarm Control Panel SLC Features RA-6075—2 x 16 LCD annunciator with a key pad in a locked metal The Potter/Nohmi protocol is a digital protocol with a proven design enclosure. for reliability and noise immunity.The system does not require special RA-6500—4 x 40 LCD annunciator with a key pad in a locked metal cable or conductors for connection of the Signaling Line Circuit as enclosure long as the cable is compliant with NFPA 70 and NFPA 72.The system LED-16—16 LED annunciator with common indicators in a locked allows for Class A or Class B installations as well as"T Taps." metal enclosure The total polling time for the protocol is about four(4)seconds which PSN-1000(E)—10 amp,remote intelligent power supply with 6 NACs, allows two polling cycles in the ANSI/UL 864 requirement of alarms 2 I/Os and a P-Link repeater reporting in less than ten seconds.Each loop is capable of 127 points with the exception of the P 100 and P200. C —Class A convertor that converts the SLC,NACs and P-Link connection Sensor Features UD-1000—UL listed,Dual line telephone alarm communicator The sensors through the fire alarm control panel provide a real DRV-50—LED driver expander,used to connect up to 50 LEDs in a time status as to the condition of the system.The smoke detector graphic display sensitivity,heat detector temperature level and drift compensation FCB-1000—Fire communication bridge,provides remote mounting of as all programmable options.The system also allows for a day/night the Ethernet connection mode where the panel automatically adjusts the sensitivity depending on the time of day.To assist in the reduction of false alarms,the smoke FIB-1000—Fiber interface module,used to extend P-Link to multi- detectors also have a maintenance warning that sends a trouble signal mode fiber(2 required) when a detector is dirty to the point that it can no longer maintain the RL,y--5—Relay module,provides 5 form C relay contacts rated at 3.0 programmed sensitivity. amps 24VDC/125AC User Interface SPG-1000—Serial parallel gateway,allows for the connection to a serial or parallel printer The fire alarm control panel has a 4 x 40 LCD display to provide information to the system status.The keypad has navigation keys The FIB-1000,FCB-1000 and the SPG-1000 may be installed in the to allow manipulation of the Menu on board the panel.The panel is stacker bracket or ordered with the optional rack mount enclosure. shipped standard with the following LEDs: AE-8—Eight card expansion cabinet • AC Power—Green AE-14—Fourteen card expansion cabinet • Alarm—Red Ethernet/I.P. Connection • Earth Fault—Amber The P300 is shipped standard with an Ethernet connection.This • Supervisory-Amber connection is the programming port and may be connected to a building • Silenced-Amber Wide Area Network(WAN)or Local Area Network(LAN).Once Trouble-Amber connected to the Internet,the panel may be selectively programmed to • e-mail alarm conditions,trouble conditions,supervisory conditions,test, The common buttons include a Silence,Reset,Acknowledge and Drill. Event History and detector status.An e-mail may be sent to the panel All of the buttons are accessible once the locked door is opened. and the panel will e-mail the event history,detector status,configuration file or server status to an authorized E-mail account.In addition, P-Link reminders may be set to send an e-mail for service,testing or other The P300 has a proprietary communication protocol that communicates conditions. through a RS-485 connection to field devices.Up to thirty-one In addition,the Ethernet connection is UL listed as an IP communicator. (31)devices may be connected to a single P-Link connection.The The IP communicator is listed to report to the UL listed Sur-Gard III P-Link includes the communication terminals and regulated 24 VDC IP receiver.The IP communicator replaces the traditional less reliable connection for the field devices.The field devices may be any of the alarm communicator transmitter that utilized telephone lines.The IP following: communicator is an active method of connection and communication to SLCE-127-Analog/Addressable loop expansion module(maximum of 2 the monitoring station. per P300) Potter Electric Signal Company,LLC • St.Louis,MO © �+���Ep 800-325-3936 • wwwpottersignal.com ■ � #8830035-REV A PAGE 3 OF 4 08/12 P POTTERMV P300 e PLUS Fire Alarm Control Panel Specifications 18.91- 17,E- Electrical Specs:AC Mains TOP 0 O O 0 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @ 240 VAC 50/60 HZ 4.11. a7s- Battery O 0 130 mA Standby 220mA Alarm O • 5 Amps power for NACs,I/O and P-Link • 3 Amps per NAC,regulated 0 • 1 Amp per I/O circuit,regulated 0 9 0 O • Battery Charger range 8-55 Ah 0 0 • Battery Charger voltage 27.3 VDC • P-Link maximum current of 1 Amp • Panel holds(2)8AH or(2)18AH batteries t LEFT51DE WGlIFfpE Cabinet • 16 gauge cold rolled steel with removable BOTTOM �• locked door • Dimensions—18 15/16"W x 27 5/16"H x 4 7/16"D • Dead front to cover all electronics • Lexan viewing window Temperature and Humidity This fire alarm control is listed and approved for operation in an indoor application with temperature range fluctuations of 32'to 120'(0°C to 49°C) with a maximum humidity of 93%non-condensing.The ideal temperature is 77°F +/-10°F(25°C+/-50C). Standards The P300 series fire alarm control panel complies with the following standards and codes. • NFPA 13,70 and 72 • ANSI/UL 864 o Local(L),Remote Station(RS),Central Station(CS),Propriety(PPU),Auxiliary(AUX) o Type of Service:Automatic(A),Manual(M),Water flow(WF)Sprinkler Supervisory(SS) o Type of Signaling:Digital Alarm Communicator(DAC),March Time(March),Non Coded(NC),Reverse Polarity(Rev Pol),Other Technologies(OT) • IBC 2000,2003,2006,2009,2012 Potter Electric Signal Company,LLC • St.Louis,MO 800-325-3936 • www.pottersignal.com P �� N8830035-REV A PAGE 4 OF 4 0/12 (E) POTTER RA_6075 The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Features Standby Current 20 mA Alarm Current 25 mA Operating Temperature 0°C-49°C(32°F-120°F)101/6-93% @ 30°C(86°F)non-condensing humidity 0 Maximum Wire Length 6500 FT 0 Maximum Annunciators 31 Dimensions(WxHxD) 8"x 6-1/4"x 1-5/8"(Cabinet) Wire Gauge 14 AWG-22 AWG Display 2 lines x 16 characters �p pqM.- , Product includes 5 year warranty .. LISTED S2930 7165-0328:0195 Description Installation The RA-6075 is a LCD remote annunciator for the PFC-6075 and The RA-6075 is connected to the PFC-6075 using a four wire RS-485 PFC-6030 addressable fire control panel.The RA-6075 communicates connection.The connection is power limited and supervised.Up to using a RS-485 connection to the main panel providing common thirty-one(31)RA-6075 LCD annunciators can be connected using indication of Alarms,Supervisory,Trouble and other system status and Class B or Class A wiring.Class A wiring requires an optional Class A control functions. Expander. The RA-6075 features a 32 character,16x2 LCD display with LED's for Power,Alarm,Supervisory,Trouble,and Silenced conditions. , It can be mounted on a single gang electrical box or a four square electrical box.The annunciator is enclosed in a sheet metal enclosure Install in accordance with compatible fire alarm panel. and has a Potter lock securing the keypad. Figure 1:RA-6075 Class B Wiring Example Figure 2:RA-6075 Class A Wiring Example To the next annunciator nnectlon onnoatlon .}. CA-6 075 P-LINK AB +Panel Panel ++ + I 1- C W Remote Annunciator nnWlon a Remote i m + < ..}. a Remote s Remote Annunciator Annunciator Potter Electric Signal Company,LLC•St Louis,MO•Cost Service:866-956-1211•Tech Support:866-240-1870•Canada:888-982-1833•www.pottersignal-com PRINTED 1N USA MFG.#5406077-REV B-1 PAGE I OF 2 9/11 (E) POTTER RA_6075 The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Address Settings The RA-6075 address is set by dip switch S 1 located on the back of the RA-6075.The address must be set in the range of 1 to 31 to be recognized by the control panel. Figure 3:RA-6075 Class A(back panel view) U .aww-w.w i t!� I Imp Dip Switch Settings Refer to the table below for dip switch settings per Annunciator Address. Annunciator Dip Switch Settings Annunciator Dip Switch Settings Address SW-1 SW-2 SW-3 SW4 SW-5 Address SW-1 SW-2 SW-3 SW4 SW-5 1 On Off Off Off Off 17 On Off Off Off On 2 Off On Off Off Off 18 Off On Off Off On 3 On On Off Off Off 19 On On Off Off On 4 Off Off On Off Off 20 Off Off On Off On 5 On Off On Off Off 21 On Off On Off On 6 Off On On Off Off 22 Off On On Off On 7 On On On Off Off 23 On On On Off On 8 Off Off Off On Off 24 Off Off Off On On 9 On Off Off On Off 25 On Off Off On On 10 Off On Off On Off 26 Off On Off On On 11 On On Off On Off 27 On On Off On On 12 Off Off On On Off 28 Off Off On On On 13 On Off On On Off 29 On Off On On On 14 Off On On On Off 30 Off On On On On 15 On On On On Off 31 On On On On On 16 Off Off Off Off On PRINTED IN USA MFG.#5406077-REV B-1 PAGE 2 OF 2 9/11 (E) POTTER PSN-1 000(E) The Symbol of Protection POWER EXPANDER Features • 10 Amp Power Supply • 3 Amps,regulated per NAC • 6 NACs Class B or 3 NACs Class A • 2 dry contact inputs • Fully programmable and monitored through control panel • Isolated P-Link repeater connection,Class A or B • Up to 31 power supplies per control panel with system wide sync • Quadrasync feature synchronizes strobes from Potter/AMSECO, Qj] •�•�p Gentex,Cooper-Wheelock and System Sensor. i V 1 l ER PSN-1 • Compatible with all Potter PFC-6000 series fire alarm control panels. ne*ftQfAftCW Power supply --•-•--. Electrical Specs • 120/240 VAC Input at 50/60 HZ • 5.1 Amps/3.0 Amps max draw • Standby Current 60 mA • Alarm Current 200 mA S2930 7165-0328: 0195 Product includes a 5 year warranty Description The PSN-1000 series is a UL listed intelligent 10 amp notification power supply and P-Link(RS-485)repeater.The power supply connects to the P-Link bus from the control panel and is operated and supervised from the panel.The power supply may be installed 6,500 feet from the control panel.The PSN-1000 then repeats the P-Link communication for another 6,500 feet. The power supply has six(6)Class B or three(3)Class A power outputs.Each output is regulated and power limited with a 3 Amp maximum rating.In addition,the PSN-1000 has two(2)programmable dry contact inputs.The dry contact inputs are Class B,supervised inputs. The power supply operates on either 120 or 220 VAC power and has a regulated 24 VDC output.In addition,the panel can charge up to 55 AH batteries and will house 18 AH batteries.The cabinet is constructed out of 18 gauge cold rolled steel with a durable red powder coat finish.A standard Potter key lock is provided for securing the door.Electrical conduit knockouts are provided on the sides and top providing installers with multiple options for installing conduits and providing proper power separations. The PSN-1000 is a self contained intelligent power supply/P-Link repeater complete with cabinet.The PSN-1000E is the intelligent power supply/P-Link repeater with additional cabinet room for the exclusive Stacker Bracket for SLCE-127 loop expanders.Both cabinets include space for 18 AH batteries. The power supplies are programmed and controlled through the main control panel P-Link bus.The panel displays any troubles or off normal conditions of the power supply and the events are stored in the panel history buffer. Each output can be independently configured to provide one of four synchronization patterns,constant power,ANSI temporal Code 3 or Door Holder power.The panel can be configured to synchronize Potter/AMSECO®,Gentex®,Cooper Wheelock®and System Sensor®. Potter Electric Signal Company,LLC•St Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•wwwpottersignal-com PRINTED IN USA MFG.#8830032-REV B PAGE I OF 2 09/14 (E) POTTER PSN-1000(E) ® The Symbol of Protection POWER EXPANDER 18.91" 17.60" TOP e G w 4.41" 3.75" DEPTH d O CV O CV h N V LEFT SIDE RIGHT SIDE BOTTOM Dimensional drawings showing the cabinet in all three planes. Knock out locations. PRINTED IN USA MFG.#8830032-REV B PAGE 2 OF 2 09/14 SYSTEM ~ ; SENSOR" Photoelectric Smoke Detectors f System Sensor i3-series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles:installation TM ease, intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its •Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included with heads).The large wire entry port and in-line terminals provide -Large wire entry port ample room for neatly routing the wiring inside the base.The base •In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single-gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,i3 boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock-action. Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features •Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and Built-in remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize nuisance alarms.2-wire P detectors can generate a remote LED- Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 •Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i3 •Wide-angle,dual-color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof i3 Loop testing via EZ Walk feature detectors in terms of percent-per-foot obscuration. • Built-in test switch Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on 2-wire i3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Listings U� M A ed m LISTED approved approved S911 3 11446 7272-1653:152 290-01-E 2093 3180932 (_j1 Smoke Detector Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31k-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2,5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model ANT-B,4WT-B)conditions,When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verifythe circuit without testing each detector individually. Electrical SpeLifications Operating voltage Nominal: 12/24V non-polarized Minimum: 8.5V Maximum:35 V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 NA maximum average;4-wire:50 uA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12V,23 mA @ 24 V Peak Standby Current 2-wire:100 pA,4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC Physical Specifications Dimensions(including base) 53 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 120°F(0°C to 49°Q;2WT-B and 4WT--B:32°F to 100°F(0°C to 37.80Q Operating Humidity Range 0 to 9S%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) Sensitivity 2,51/o/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12 V,23 mA @ 24 V 4WT-B Yes 4-wire 20 mA @ 12 V,23 mA @ 24 V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter STEM 020095ystem Sensor. SENSOR 3825 Ohio Avenue•St.Charles,IL 60174 Roductswproanot information, nfer ationcnangewntha latest e systemsensa.eet ra Phone:800-SENSOR2•Fax:630-377-6495 N"entplOa"n'"r"mao-0318 007-6/09.0st—on"this aztzsneer A05-0318-007.6/09•g2169 E) POTTER PULL STATION SERIES DIE-CAST METAL The Symbol of Protection MANUAL PULL STATIONS • UL and cUL Listed,FM Approved,CSFM Listed,MEA ' Approved,ADA Compliant • Single or Dual Action • Terminal connectors PULL i 0 , 1 i 10 Amp Snap Action Switch Gold plated SPST contacts • Optional auxiliary contacts • Mounts on standard single gangbox • Surface backboxes available • High-gloss red enamel finish • Glass breakrod Made in the U.S.A. Description Engineering Specifications The Potter Pull Station Series offers a complete line of die-cast pull The contractor shall furnish and install the Potter series of pull stations for a variety of applications focusing mainly on fire alarm stations as indicated.The pull station shall be die cast construction systems.The pull stations are available in single or dual action with a"T"type pull handle that is ADA compliant.Single action pull models.All of the pull stations have a 10-amp snap action switch and stations shall be a P32-1T.Dual action pull stations shall be the Potter a dedicated terminal block for the ease of wire connections.All of P32-IT LP.Any manual pull station installed in an outdoor or wet the metal is completely coated to inhibit corrosion and provide for a location shall be a RMS-IT WP weather proof unit.The contact shall uniform and quality finish. be a single pole,single throw switch rated at 1 amp 30V DC/125V The standard models have a hex key reset,however a key reset is also AC.The device shall have a terminal block for ease of wiring.Once available.The models are available with shallow and deep surface activated,the pull station shall be reset by opening the front cover. mount back boxes and as a weatherproof version. Opening of the cover in a normal state shall initiate an alarm. Operation Specifications The Potter single action series of pull stations operate by pulling Switch Rating: 1 Amp @ 30 VDC the white operating handle straight down and the handle will lock 10 Amps @ 125 VAC into place.The dual action stations require the lifting of the front Pull Station Dimensions: 4-3/4"H x 3-1/4"W x 7/8"D cover and then pulling the white operating handle straight down.The Color:Red with raised white letters,white pull bar with raised red letters stations are reset by opening the front and placing the handle in the normal position. For special application manual stations see bulletin#8910014. For explosion proof manual stations see bulletin#8880014. Ordering Information Type Model Number Stock Number Contact Type P32-IT 1000447 SPST RMS-2T 1000477 DPST Single Action RMS-6T 1000478 DPDT RMS-1T KL 1000451 SPST RMS-IT KO 1000450 SPST,key operated,no pull Weather Proof RMS-IT-WP 1000401 Dual Action P32-IT LP 1000476 SPST Weather Proof Dual Action RMS-IT WP-LP 1000403 Accessories Notes Dual Action RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1000470 Replacement glass rods(10 per pkg) Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8900097-REV L PAGE I OF 1 9/10 P POTTER® O"M1" DCM-4 The Symbul of Protection Dual Contact Module Features • Single module with dual contact monitoring inputs • Two(2)Class B or one(1)Class A monitoring inputs • SLC Class A(Style 6,7)&Class B(Style4) • Mounts in a standard 4"or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 14 AW G • Product includes a 5 year warranty ars,....._. ;VOTE: This addressable module does not support 2-wire smoke ii detectors. Stock Number: 1430822 r(@Us LISTED S2930 7165-0328:0196 Application Technical Specifications The DCM-4 is compatible with Potter's PFC-6000 series and PFC- Operating Voltage 22.0-24.OV 8500 addressable fire alarm control panels.The DCM-4 is an interface Max SLC Standby Current 325 µA module used to monitor dry contact devices such as sprinkler water Aux Power Required 1mA flow,valve tamper switches,or conventional pull stations.The module is capable of monitoring two separate Class B or one Class A circuits. Max Wiring Resistance of IDC 1000 Max Wiring Cpacitance of IDC 1 µF EOL Resistor 5.1 K D Description Operating Tempurature Range 32 to 120°F(0 to 49°C) The DCM-4 uses two (2) consecutive SLC loop addresses when Operating Humidity Range 0 to 93%(non-condensing) monitoring two(2)Class B circuits or one(1)address when monitoring or G3 units a single class A(Style D)circuit.The module mounts on either a 4" Max no.of Module Per Loop (Class 127 waits(Class A) square or double gang box.The module is capable of monitoring two (2)separate class B circuits making it ideal for monitoring sprinkler Dimensions 4.17"(106mm)L X 4.17" waterflow and valve tamper switches when they are located in the same (I 06mm)W x 1.14"(29mm)D proximity.The DCM-4 includes one red LED to indicate the modules Standard 4"Square or status.In normal condition,the LED flashes when the device is beingMounting Options Double Gang Box polled by the control panel.When a contact is activated,the LED will Shipping Weight 0.6 Ibs light continuously and in case of an open circuit,the LED will turn off. Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com 8830008-REV B • 7/14 PAGE l OF 2 P POT TFR®A AOHM/ DCM-4 The Symbol of Protection Dual Contact Module Setting the Address Each addressable module,smoke sensor,heat detector and combination sensor/detector must be assigned an address prior to installing the device.The address is set using either the hand held device programmer or the addressing feature on the PFC 6000/PFC 8500 Series control panels.When the DCM- 4 is used to monitor two individual Class B circuits a single device address is assigned,with the second address number assigned automatically by the module assuming the next consecutive address.For example,if the first address number is assigned as"2",the second address number will automatically be assigned as SLC device address"3". Before connecting a device to the SLC loop,take the following precautions to prevent potential damage to the panel or device verify the following: 1.Power to the device is removed 2.Field wiring is correctly installed. 3.Field wiring has no open or short circuits. Installation Using Compatible Electrical Box e 0 0 b ° ° oos ° o 0 Wiring Diagrams DCM4 With One ClassA Circuit NO] FROM FACP OR C1 - PREVIOUS MODULE S+ ZI S- NO' TO THE NEXT MODULE )PI C2 SELECT STYLE 13 1110 LED O Z2 NOTE:END-OF-LINE RESISTOR IS NOT REQUIRED DCM4WithTwo ClassB Circuits NOI FROM FACP OR CI PREVIOUS MODULE S+ ZI END-OF-LINE RESISTOR 5.1K OHM 1/2W C2 g- NO2 TOTH E NEXT MODULE ppSp-p 00008 LED O Z2 SELECT STYLE B 0000 END-OF-LINE RESISTOR 5-1KOHM 1/2W Potter Electric Signal Company,LLC St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 www.pottersignai.com IBO 9081c2008 1 DESIGNING.MANUFACTURING, &DISTRIBUTING QUALITY SYSTEMS 8830008-REV B • 7/14 PAGE 2 OF 2 ENTEX CORPORATION Low Frequency Audible Signal GHLF Applications `�F•�A VDC The GHLF is a high quality,low profile, low frequency audible appliance that offers a V dependable audible alarm with a low current draw. The GHLF is ideal for any ' P t S occupancy that requires notification appliances. The GHLF horn offers a 520 Hz square wave,temporal 3 tone. A jumper selection is available for normal or loud decibel tone. A temporal 4 pattern is available when used with the Gentex GTSM Synchronization Control Module. The GHLF is shipped with a standard 4"metal mounting plate which incorporates the popular Super-Slide®feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The GHLF also features the patented Checkmate'-Instant Voltage Verification feature which allows the installer to check the voltage drop and match it to the blueprint. The GHLF horn is listed to ANSI/UL 464 and CAN/ULC S525, is listed for use with fire Product Listings protective systems and is warranted for three years from date of purchase. SIGNALING Standard Features i' _ • Nominal voltage 24 VDC • Input terminals accept 12 to 18 AWG C ul US . a Unit Dimensions:6-1/8"(15.55 cm)high x • Produces a 520Hz square wave,temporal 3 LISTED 5-1/2"(13.97 cm)wide x 1-5/8"(4.13 cm) tone deep • Jumper selection for normal or loud dBA • ANSWL464 Listed • Super-Slide®Bracket-Ease of Supervision • Temporal 4 pattern available when used • CAN/ULC S525 Listed Testing with Gentex GTSM Synchronization Module e CSFM: Pending • Checkmate®-Instant Voltage Verification • Temporal 4 520Hz measured per Product Compliance • Synchronize horn with Gentex GTSM ANSI/UL 2075 • NFPA 72 Synchronization Control Module • Tamperproof re-entrant style grill and • IBCAFCARC • Prewire entire system,install mounting locking screw(optional use) • Quality Management System bracket,then install signals • Faceplate available in red or off-white is certified to:ISO 9001:2008 Model Number Part Number Nominal Voltage Model Designations: R=Red Faceplate MEMBER JHLFW 904-0530-002 24 VDC W=White Faceplate ASSEMBLED IN 3HLFR 904-0531-002 24 VDC All units are plain(no lettering) THE USA Horn Decibel Levels: 24VDC Nominal Horn Horn Current Ratings Reverberant Room Current Ratings(mA) Over Input Voltage Range of 16-33V(mA) Minimum SPL Minimum SPL 24VDC 24VDC 24VFWR 24VFWR Regulated Regulated Regulated Regulated at 10Ft.Per at 10Ft.Per Operating Operating Operating Operating 24VDC Max 24VDC Max 24VFWR Max 24VFWA Max, Horn Mode ANSI/UL 464 ANSI/UL 464 Current Current Current Current Operating Operating Operating Operating (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) Current Current Current Current (NORMAL) (LOUD) (NORMAL) (LOUD) temporal 3 520 Hz 77.8 dBA 79.8 dBA 72.1 mA 120.1 mA 104.6 mA 158.4 mA 99.4 mA 155.8 mA 152.1 mA 213.5 mA temporal 4 520 Hz"1 81.5 dBA 1 83.4 dBA 75.9 mA 1 116.0 mA 1 108.1 mA 182.0 mA 100.1 mA 1 157.2 mA 1 163.1 mA 1 235.2 mA •Temporal 4 520 Hz measured per ANSI/UL 2075 NOTES: • Operating temperature:32'to 120°F(0'to 49°C).The GHLF is not listed for outdoor use. • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. RMS current ratings are per ANSI/UL average RMS method. ANSI/UL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units). For unfiltered FWR ratings,see installation manual. GHLF 24 VDC RIES NOTES: C Listed THIS APPLIANCE IS NOT RECOMMENDED FOR USE ON CODED OR Control Signal Signal PULSING SIGNALING CIRCUITS Panel THE FOUR PULSE TEMPORAL PATTERN(TEMPORAL 4)CAN ONLY BE Supervised 0 0 0 0 OBTAINED ON THIS PRODUCT WHEN USED IN CONJUNCTION WITH Signal Circuit THE GENTEX GTSM SYNCHRONIZATION MODULE \ + END OF E SEE GTSM CONTROL MODULE MANUAL(550-0632,MANUAL ISSUE RESISTOR DATE(02-01-15)FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. GTSM MANUAL CAN BE OBTAINED AT WWW.GENTEX.COM/FIRE OR CALL GENTEX CORPORATION AT 1-800-436-8391. DO IfII)FW" L tyT LOCKING o ^ %CS o s+ r S j SCREW (o 0 3 o o H. (optional)U RED WIRES M � O BLACK WIRES li► - o Go 0 0 ,o N RMAL-LOUD o DECIBEL JUMPER. o •'•" p O FOR LOUD DECIBEL INSTALL JUMPER. SLIDE ONTO BRACKET Gentex Checkmate" Gentex Super•Slide® LOCKING Instant Voltage Verification: Mounting Bracket: SCREW It is often necessary to confirm the voltage drop Allows the installer to pre-wire the system, (optional) along a line of devices.The access holes are test for system supervision,remove the provided in the back of the terminal block to signal head until occupancy,switch out allow the voltage to be measured directly without Gentex signals without changing removing the device.Typically this would be done mounting brackets and has locking edge at the end of the line to confirm design criteria. connector for snap-in-place installation. Most measurements will be taken using the S+ and S-locations although access is provided to other locations. NOTICE.CARE SHOULD BE TAKEN TO NOT SHORT THE TEST PROBES. Architect & Engineering Specifications The alarm horns shall be Gentex model GHLF.The appliance shall be listed with Underwriters Laboratories(ANSI/UL)for use with fire protective signaling systems(ANSI/UL 464)and with CAN/ULC S525 with intended use in fire alarm systems. The GHLF will produce a peak sound output of 88.3 dBA as measured in an anechoic chamber. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power at 24 VDC. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton TheseImportant Noticmaterials GHLF-01 O GENTEX These materiels have been re xg purported by Gentex serve leg lsdOce a for informational adonel purposes only,are neceexma summary,and are not and waed to serve re legal n plied and should not be used as such. Gentex makes no representations and warranlles,express or implied,that these materials are complete and CORPORATIONaccurate,up-todate,or in compliance with all relevant local,state and federal laws,regulations and rules. The materiels do not address all legal considerations as there is inevitable uncertainty regarding interprelatton of laws,regulations and rules and the epoicadm of such laws,regulations and rules to Fire Protection Products Group•vvvVW.gentex.com particular fact patterns.Each person's activities can differently allect the obligations that exist under applicable laws,regulations a rules.Th4mlore,these materials should be used only for inform.1-1 10985 Chicago Drive •Zeeland, Michigan 49464 purposes and should not be used as a substitute for cooking ptoteselmal legal advice,Gentex wJl not be 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax responsible for any action or failure to act in reliance upm the mlormatmn contained m Ibis mailm at Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. (E) POTTER MHT 1224 SERIES ® The Symbol of Protection LOW CURRENT MINI-HORN Features • Single unit is capable of 12 or 24 VDC determined by the input E voltage Unit Dimensions:4.48"(11.38cm)high x 2.84"(7.21 cm)wide x 0.5"(1.27 cm)deep • Jumper selectable temporal 3 or continuous tone • Hom frequency is 31001lz Terminal blocks(12 AWG to 18 AWG) Low current consumption 017 Variety of mounting options for new construction and retrofit [loll, o "' applications 1 Synchronize using the AVSM Series control module • ANSI/UL 464 listed for fire protective service • Textured finish high impact plastic faceplate,available in red or off-white Ordering Information Operating Temperature(indoor use only) Stock Number Model Number Model Designations 320 to 120OF(00 to 49°C) 4890001 MHT 1224R R=Red facepaate 4890002 MHT 1224W W=Off-White faceplate 4890003 MHT 1224PR P=Plain 4890004 MHT 1224PW SISMAUNG LISTED Product includes a 5 year warranty Description The MHT-1224 Series mini-horn is a high quality remote The MHT-1224 can be used on the same sync circuit(AVSM audible signaling appliance that offers dependable remote annunciation. Series Control Module)as other Potter signals.The MHT-1224 Series The MHT 1224 is ideal for applications where a dependable audible is ANSI/UL 464 listed for use with fire protective systems. alarm signal is required in applications such as hotels, dormitories, and apartments.The MHT-1224 is listed for use with both filtered and unfiltered power and a jumper is provided to select either temporal 3 or continuous tone. Architect&Engineering Specifactions The alarm horns shall be Potter model MHT 1224.The appliance shall be listed with Underwriters Laboratories(ANSI/UL)for use with fire protective signaling systems(ANSI/UL 464)and produce a peak sound output of 90dBA or greater as measured in an anechoic chamber.The appliance shall be of solid-state construction and be polarized to operate from 8-33VDC with a 22mA current drain at 24VDC.The appliance shall be provided with 2 terminals,and mount to a variety of single-gang back boxes. Potter Electric Signal Company,LLC•St,Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.com PRINTED IN USA WG.#8830065-REV A PAGE I OF 2 06/13 1 (E) POTTER MHT 1224 SERIES ® The Symbol of Protection LOW CURRENT MINI-HORN Mini-Horn Wiring UL MHT-1224 MHT-1224 LISTED WIRING DIAGRAM FOR DUAL CLASS B CIRCUITS WITH A SINGLE AVS44 CONTROL MODULE CONTROL PANEL + _ + 0 0 SYNCHRONIZATION FACP MODULE 00'014 95MM SIP ENO OF LINE r CRb-U� RESISTOR Or- 1 0- EOLR z:n z:n z:o RED SIGNAL CIRCUITS } 41AfK 40 BLACK PA AC A!ACK Wiring Diagram EOLR Mini-Horn Wiring 0 Use a screwdriver to break the jumper for a continuous tone. �^ o DO NOT BREAK t ' ® JUMPER IF TEMPORAL 3 TONE IS NEEDED. Horn Mode Minimum SPL at 10 Minimum SPL at 10 Reverberant dBA at 10 In Anechoic MHT 1224 Current Ratings feet per ANSFUL feet per ANSUUL feet per ANSUUL 464 Room dBA @ 24 VDC 22 mA 464 at 24 VDC 464 at 12 VDC 10 ft. Temporal 3 81 dBA 78 dBA 78-86 90 24 VDC UL Max 18 mA Continuous 86 dBA 83 dBA 78-86 90 12 VDC UL Max 13 mA NOTES:The sound output for the temporal 3 tone is rated lower since the time the hom is off is averaged into the sound output rating.While the hom is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. ' RMS current ratings are per ANSUUL average RMS method.ANSI/UL max current is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units)(8-17 VDC for 12 VDC units).For strobes,the ANSI/UL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units)(8 VDC for 12 VDC units).For audibles,the max current is usually at the maximum listed voltage.For unfiltered FWR ratings,see installation manual. PRINTED IN USA WG.#8830065-REV A PAGE 2 OF 2 06/13 Technical Data TDO01009EN Exceder LED Low Frequency Sounder Strobes and Sounders Description •.•.��...��.•.� Eaton's Cooper Notification business has developed the Wheelock ''•" ' ' ' Exceder LED Low Frequency Sounder Strobes and Sounders to meet the new National Fire Protection Association (NFPA)low ;.;.;.;.;;.•.;.;.;.; frequency sounder requirements for sleeping rooms -NFPA 72 for ::; :•:•:•:•:•:• fire alarm and NFPA 720 for Carbon Monoxide(CO)alarm. In a single .;.;:;:•;•:•;:;:;o;: • •.• device,the Exceder LED Low Frequency Sounders can provide alarm •.•�•�.�•:::,.;�.� signals for dual applications-T3(Fire)and T4(CO)tones. It is the • • ••••°'•'• • first product in the industry to be listed to the audibility requirements of UL 2034 and UL 2075 for CO applications. �rtAi The Exceder LED Low Frequency Sounder Strobes and Sounders feature multiple 520 Hz modes of operation:T3(fire),T4(CO), Continuous,T3/T4 Sync Control. The 520 tone is generated within the appliance itself. When the selector switch is set for T3 or T4,the sound pattern is also generated within the appliance. When the selection switch is set to continuous,the product is listed for coded operations. The T3/T4 pattern or other pattern must be generated by the FACP according to the alarm condition sensed by the panel (fire or CO alarm). When the device is set to T3/T4,the appliance can switch from T3 to T4 based upon the condition sensed by the FACP and passed to the '•°•'"'• Wheelock DSM module. •.•.°.••ems Like the entire Wheelock Exceder LED product line,the Low Frequency Sounder Strobes will utilize Light Emitting Diode(LED) as the light source—a breakthrough optical design, resulting in best- in-class efficiency that enables material and system cost savings, allowing for a greater number of appliances on the notification appliance circuit and fewer power supplies. All LLFHS strobe models include a 110 candela setting. Providing a sleek aesthetic appearance,the Exceder LLFHS and LLFHN models feature one of the industry's smallest footprints and a sleek, modern, low-profile design. Installers will benefit from its comprehensive feature list, multiple 520 Hz modes of operation, lowest current draw, no tools needed for setting changes, and convenient mounting options.These products are suitable for indoor wall-mount applications.The Sounder and Sounder Strobe models are for 24V operation. Exceder LED Sounder Strobes may be synchronized when used in conjunction with the DSM Sync Modules,Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol.Wheelock synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. The Fxceder LED Low Frequency Sounders and Sounder Strobes are UL Listed for indoor use under Standard 1971 and 464 and ULC under 5525 and S526. The appliances are Restriction of Hazardous Substances(RoHS)compliant and contain no mercury or other FM,TON hazardous substances. Powering Business Worldwide Technical Data TDO01009EN Exceder LED Low Frequency Sounder Strobes and Sounders Effective May 2014 Features Drawings • Meets dual low frequency sounder codes for sleeping rooms in a - single device • NFPA 72 for fire alarm NFPA 720 for CO alarm d p000 • 4 Settings in 1 device 000o000O900000000 00 T3 (fire) 0°000,00000000 910000000000 0°°0 °a c 0 o°o 0000° o 0 o 00000000 °0 00°o° • T4(CO) o°o0000°Oo°o°00%%0o°o° 0000000°00000 00 00 0 0 0° • Continuous(Coded) 00000%o00000000 0 000°00° 6 10 • T3/T4 0°0 00o°,o°OpO°o00o°o Qo°� p0 00000°°000000°00o • Energyefficient 000oes0o°O0o0seo0o0 o o eeeee o 0 • Patented LED technology provides industry's lowest current oOpoe°eeo0°0 draw • Low-profile design Smallest footprint with sleek, modern aesthetics • 110 candela setting 1,40 • Easy-to-install • Finger slide switches-No tools needed for setting changes - • Built-in level adjustment feature and snap-on grille cover Figure 1.Wall Low Frequency Sounder Strobe • IN/OUT screw terminals using#12 to#18 ____. 29 AWG wires Mounting Options include Exceder LSPKBB backboxes and 4" square backboxes ;e°o°. 00�00° 000 p°°O°°°°000 • Strobe synchronization components o0oOo000000000000 00 0°00000°0°000000°0o Meet synchronizing standards with Wheelock's DSM Sync 0 Qo°000000S8o0o1 0 0g Modules or PS-6/8 Power Supplies °o°0°0°0°0°0 0°0°0°0° PP 10v0o0o00000000000000 • Compliance o0000 00°0$o°o°eo°oo°eo°v 6.10 UL 2034, UL 2075, UL 1971, UL 464, ULC S525, ULC S526 °o0 0 0°0000°0°o0°o°Oo�o° 000°000o0o0 0oa o °°o°0°e°e°e°ee°0°o°0 • California State Fire Marshal(CSFM) 00000000000 • ADA/NFPA/ANSI/OSHA oeaeoa • RoHS m Note: All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. A WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION Figure 2.Wall Low Frequency Sounder INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT.VISIT WWW.000PERNOTIFICATION.COM OR CONTACT Table 1.Horn Strobe Current Draw COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. UL/ULC Max Current a FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR Exceder LED Sounder Strobes 24VDC WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, 1633 Volts WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR Model Horn Setting 110 cd DEATH TO YOU AND/OR OTHERS. LLFHS Continuous 0.292 Code 3 0.292 Code 4 0.292 General Notes Code 3/Code 4 0.292 • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range." Note that NFPA-72 specifies a Table 2.Horn Only Current Draw flash rate of 1 to 2 flashes per second and ADA Guidelines specify UL/ULC Max Current a a flash rate of 1 to 3 flashes per second. Exceder LED Sounders 24VDC • All candela ratings represent minimum effective Strobe intensity Model Horn Settings 16.0•33.0 _ based on UL 1971. LLFHN Continuous 0.113 Code 3 0.113 Code 4 0.113 Code 3/Code 4 0.113 Z EATON www.eaton.com Technical Data TDO01009EN Exceder LED Low Frequency Sounder Strobes and Sounders Effective May 2014 Table 3. Sound Output(SPL►-UL Table 4. Sound Output(SPL►-ULC LLFHS/LLFHN 24V LLFHS/LLFHN Reverberant dBA per UL 464 dBA per ULC S525-07c Description 16.0V 24.OV 33.OV Description 16.0V 24.0V 33.OV Continuous 80 80 80 Continuous 80 80 80 Code 3 76 76 76 Code 3 80 80 80 Code 4 b 85 85 85 Code 4 80 80 80 Code 3/Code 4 76 76 76 Code 3/Code 4 80 80 80 Table 5. Specification&Ordering Information Syync w/DSM or Mudel 9lrube Carrdele ReJ White Lettering Wheelock Power Supplies Sounder Strobes LLFHSR 110 X FIRE X LLFHSW 110 X FIRE X LLFHSR-AL 110 X ALERT X LLFHSW-AL 110 X ALERT X LLFHSR-CO 110 X c0 X LLFHSW-CO 110 X CO X LLFHSR-N 110 X No Lettering X LLFHSW-N 110 X No Lettering X Sounders LLFHNR-AL X ALERT X LLFHNW-AL X ALERT X LLFHNR-CO X CO X LLFHNW-CO X CO X LLFHNR-N X No Lettering X LLFHNW-N X No Lettering X Accessories Description Red White LSPKBB-R 0756 Exceder LED Backbox X LSPKBB-W 0757 Exceder LED Backbox X Table 6. Specifications Physical Material Red or white textured UV stabilized,colored impregnated engineered plastic. Exceeds 94V-0 UL flammabil- ity rating Weight 1.10 lbs. Lens Light Emitting Diode(LED)in a rugged Lexan lens Dimensions 6.1"H x 4.56"W x 1.4" D Operating Temperature Indoor:33.8°F to 120.2°F WC to 49°C)and maximum humidity of 85% Mounting&Wire Connections Mounting(indoor only) Wall-mount applications only. Exceder LSPKBB backboxes or to 4" square backboxes Wire Connections #12 through#18 AWG Power&General Operating voltage 24 VDC: 16-33 VDC Strobe Output Rating UL 1971: 110 candela output Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules, PS-6/8 Power Supplies, using Wheelock patented sync protocol Temporal Audible Pattern Continuous, Code 3,Code 4 or Code 3/Code 4 Sync Control. The Code 3 temporal pattern (1/2 second on, 1/2 second off, 1/2 second on, 1/2 second off, 1/2 second on, 1-1/2 off and repeat)is specified by ANSI and NFPA 72 for standard emergency evacuation signaling. The Code 4 temporal pattern(four cycles of 100 milliseconds t 10 percent"on" and 100 milliseconds t 10 percent"off;'followed by 5 seconds t 10 percent"off) is specified by NFPA 720. a RMS current ratings are per UL maximum RMS method.UL max current rating is the maximum RMS current within the listed voltage range(16-33v). For strobes the UL max current is usually at the minimum listed voltage. For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings,see installation instructions. b Code 4 setting rated per UL 2075,UL 2034. c For dwelling use only. 3 EATON www.eaton.com 1 Technical Data TDO01009EN Exceder LED Low Frequency Sounder Strobes & Sounders Effective May 2014 Architects and Engineers Specifications backboxes and to standard 4" square backboxes. The sounder and The low frequency sounders and sounder strobes appliances shall sounder strobe shall incorporate a mounting plate with a snap-on be Wheelock®ExcederT"' LED Series LLFHN Sounder and LLFHS grille cover and shall mount to standard electrical hardware requiring Sounder Strobe for wall-mount applications with a low profile design no additional trimplate or adapter. Removal of an appliance shall or approved equals.The sounders shall be UL Listed under UL 464 result in a supervision fault condition by the Fire Alarm Control Panel for Fire Protective Service and to the requirements of UL 2034/UL (FACP). All notification appliances shall be backwards compatible. 2075 for CO applications and ULC S525.Sounders equipped with The Series LLFHN wall model shall have a low profile measuring strobes shall be listed under UL 1971 for Emergency Devices for the 6.1" H x 4.56"W x 1.29" D.The Series LLFHS wall model shall have Hearing-Impaired and ULC S526.The Series shall be Restriction of a low profile measuring 6.1" H x 4.56"W x 1.4" D. Finish shall be Hazardous Substances(RoHS)compliant and contain no mercury or red or white.Special lettering,ALERT, CO and No lettering,shall be other hazardous substances. In addition,the sounder strobes shall available. meet the requirements of FCC Part 15.All inputs shall be compatible When synchronization is required,the appliance shall be with standard reverse polarity supervision of circuit wiring by a Fire compatible with Wheelock's DSM Sync Modules, PS 6/8 Power Alarm Control Panel(FACP)with the ability to operate from 16 to 33 Supplies,or other manufacturer's panels with built-in Wheelock VDC. Patented Sync Protocol.The strobes shall not drift out of synchro- nization at any time during operation. If the sync protocol fails to The Series LLFHS Sounder Strobe shall produce a flash rate of one operate,the strobe shall revert to a non-synchronized flash-rate and (1)flash per second over the Regulated Voltage Range and shall still maintain (1)flash per second over its Regulated Voltage Range. incorporate a Light Emitting Diode(LED)as the light source with a The appliance shall also be designed so that the audible signal may rugged Lexan®lens.The Series shall be of low current design.The be silenced while maintaining strobe activation when used with strobe intensity shall have a 110 candela for wall mount applications. Wheelock patented sync protocol. The audible shall have a minimum of four(4) 520 Hz modes of operation:T3 (fire),T4(CO), Continuous,T3/T4 Sync Control. UL 1971, UL 464, ULC S525, ULC S526, CSFM, FCC, RoHS The Series LLFHS and LLFHN shall be designed for indoor surface or flush mounting. Mounting options shall include LED speaker Note: Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. ma WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Cooper Notification 273 Branchport Ave. Long Branch,NJ 07740 CooperNot ifi cati on.com ©2014 Eaton All Rights Reserved Eaton is a registered trademark. _ Printed in USA Publication No,TDO01009LN All other trademarks are property Powering BusinessWorldwede June 2014 of their respective owners. COOPER Notification ED M Strobe, Horn Strobe, and Horn Notification Appliances FIRS v ceiling wall Description: The Wheelock'®ExcederT"Series of notification appliances feature a sleek modern design that will please building owners with reduced - Save up to 48% in current draw* total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw,no tools needed for setting changes,voltage test - Up to 9 models now in 1 appliance points, 12/24 VDC operation,universal mounting base and multiple mounting options for both new and retrofit construction. - Save up 1 40/O to cost of installation** The Wheelock®ExcederTm Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe models feature an industry first of 8 candela settings on a single Sleek Modern Aesthetics appliance.Models with an audible feature 3 sound settings(90,95, 99 dB).All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Finger Slide Switches Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederT"^ Series of wall and ceiling notification Voltage Test Points appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting Multiple Voltages base can be pre-wired to allow full testing of circuit wiring before ° the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt,dust,paint 3 Audible Settings and damage to the contacts. The Contact Cover also acts as a 90,95,99 dB shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while 8 Candela Settings'#` it is on the UMB. When the Contact Cover is removed the circuit Wall-15/1575/30/75/95/110/135/185 will show an open until the appliance is installed.The UMB allows Ceiling-15/30/60/75/95/115/150/177 for consistent installation and easy replacement of appliances if required.Wall models provide an optional locking screw for extra UU Universal Mounting Base secure installation, while the ceiling models provide a captivated Ceiling and Wall screw to prevent the screw from falling during installation. Mounts to 5 Backbox Types Compliance Environmentally Friendly -UL 1971, UL 464, ULC, CSFM, FM Low Current Draw -ADA/NFPA/ANSI/OSHA -RoHS Compatibility and Requirements -Synchronize using the Wheelock®Sync Modules or panels with built-in Wheelock®Patented Sync Protocol -Compatible with UL"Regulated Voltage"using filtered VDC or unfiltered VRMS input voltage -Strobes produce 1 flash per second over the"Regulated Voltage"range `Compared to competitive models """Patented ""Compared to previous models I NOTE:All CAUTIONS and WARNINGS are Identified by the symbol A.All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT W W W.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: •Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range'. •All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. •Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32•F to 120•F(0"C to 49•C)and maximum humidity of 93%(t 2%)UL 464(65%UL 1971). •Series Exceder horns are under UL Standard 464 for audible signal appliances(Indoor use only). Low Current Draw = Fewer Power Supplies Strobe Ratings per UL Standard 1971 UL Max Current' 24 VDC/24 FWR 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 0.253 0.110 0.140 STC 8.0-33.0 0.061 0.085 0.103 0.135 0.163 0.182 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 &Anechoic at 24 VDC UL Max Current' at Anechoic 99 dBA 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 _ 0.242 0.282 10.125 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 11IM0.087 0.128 0.139 0.163 0.186 0.230 0.272 0.122 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 Horn Ratings per UL Anechoic �? Model Regulated Range VDC Voltage 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 18.0-17.5 10.047 1 0.0261 0.017 "UL max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units).For strobes the UL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage(33 VDC for 24 VDC units). For unfiltered ratings,see installation instructions. Specification & Ordering Information JSync w/ H odel Strobe DSM or 12124 VDC* Mounting Candela Wheelock Power Options Supplies R 16/1575/30/75/95/110/135/185 X X UMB** W 15/1575/30/75/95/110/135/185 X X UMB** RC 15/30/60f75/95/115/150/177 X X UMB** WC 15/30/60f75/95/115/150/177 X X UMB** R 15/1575/30f75/95/110/135/185 X X UMB** W15l1575/30f75/95/110/135/185 X X UMB*' TRC 15/30/60f75/95/115/150/177 X X UMB*' STWC 15/30/60/75/95/115/150/177 X X UMB** HNR • X X UMB** HNW X X UMB** HNRC .. X X UMB** HNWC X X UMB** *12 VDC models feature 15&15/75 settings **UMB=Universal Mounting Base Model Legend HN = Horn A =Agent Lettering ST =Strobe (Strobes only) -� HS = Horn Strobe AL=Alert Lettering C =Ceiling Mount (Strobes only) W =White N =No Lettering R = Red (Strobes only) r Example 1: STRC=Strobe,Red,Ceiling Mount / Example 2: HSR=Horn Strobe,Red,Wall Mount / Example 3: HSW=Horn Strobe,White,Wall Mount I Example 4:STW-AL=Strobe,White,Wall Mount,Alert Lettering ' Example. Example: HSWC 46 c � *UMB Contact Co NOTE:Due to continuous development of our products,specifications and offerings are subject to change without notice In accordance with Cooper Wheelock Inc.,dba Cooper Notification standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock®ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design. Where Multi-Candela appliances are specified,the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount.The selector switch for selecting the candela shall be tamper resistant.The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g.ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HSAudible Strobe,ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP). The mounting base shall be the same base among all horn, strobe, horn strobe,wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24"H x 4.58"W x 2.19"D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63" D. Series HNC ceiling shall have a diameter of 6.68"x 1.50"D. When synchronization is required,the appliance shall be compatible with Wheelock®'s DSM Sync Modules,Wheelock®Power Supplies or other manufacturer's panels with built-in Wheelock®Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate,the strobe shall revert to a non-synchronized flash-rate and still maintain(1) flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock®synchronization protocol. Wall Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal(CSFM), ULC, FM, RoHS Ceiling Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal(CSFM), ULC, FM, RoHS R' WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder- Spec Sheet 5/13 NJ Location Long Bralldi, NJ •0 800-631-2148 Cooper Notification is Wheelock*=MEDC SAFEPATH' WAVS COOPER Notification E) POTTER 5-24 & HA-24 ND SELEC'I'Al3LE CANllELA The Symbol of Protection STROBE & HORN/STROBES Features • 24VDC units have field selectable candela options of 15,30,60, 75,&110 • Super-Slide®Bracket-Ease of Supervision Testing Checkmate®-Instant Voltage Verification • Synchronize strobe and/or horn with AVSM Control Module • Prewire entire system,install mounting bracket,then install signals Documented lower installation and operating costs • Input terminals accept 12 to 18 AWG • Switch selection for high or low dBA • Switch for chime,whoop,mechanical and 240011z tone w Tamperproof re-entrant style grill Switch for continuous or temporal 3 tone(not available on whoop tone) 1 Surface mount with the AVBB(Surface Mount Back Box) I Silence audible while visual appliance will remain flashing(for use in accepted jurisdictions) • Faceplate available in red or off-white Operating Temperature • 32°F to 120°F(0°C to 49°C).The HS and S Series are not listed for outdoor use. Unit Dimensions • 5"(12.7 cm)high x 4.5"(11.43 cm)wide x 2.5"(6.35 cm)deep U� LISTED S3247 Description The S-24/HS-24 Series is a low profile strobe and horn/strobe This Series is shipped with a standard 4" metal mounting combination that offers dependable audible and visual alarms and the plate which incorporates the popular Super-Slide®feature that allows absolute lowest current available. the installer to easily test for supervision.The product also features a locking mechanism which secures the product to the bracket without The S-24 & HS-24 Series 24VDC offers tamperproof field any screws showing. selectable candela options of 15,30,60,75,and 110 candela. The S-24/14S-24 also features the patented Checkmate® - The Strobe and Horn/Strobe offers a continuous or sync Instant Voltage Verification feature which allows the installer to check temporal three in 240011z and mechanical tone, a chime and whoop the voltage drop draw and match it to the blueprint. tone.All tones are easy for the professional to change in the field by the use of switches. The S-24&HS-24 Series appliances are ANSI/UL 464 and ANSI/UL 1971, listed for use with fire protective systems and are The S-24 & HS-24 Series has a minimal operating current warranted for three years from date of purchase. and has a minimum flash rate of 1Hz regardless of input voltage. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA•CustService:866-572-3005-Tech Support:866-956-0988-Canada888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 1 OF 4 06/13 E P TTF1Z 5-24 & H 5-24 O SELECTABLE CANDELA The Symbol of Protectlon STROBE &HORN/STROBES Tone Switch Locations TONE SWITCH POSITION . 3 1 4 5 ,® 0 Mechanical Temporal 3 ON ON ON N® Mechanical-Continuous OFF ON ON S¢ 240011z-Temporal 3 ON OFF ON Cc 2400Hz-Continuous OFF OFF ON A® S¢ S- Chime-Temporal 3 ON ON OFF CZE rn® 14+ Chime-Continuous OFF ON OFF ® H- Whoop ON OFF OFF Whoop OFF J. OFF OFF NOTE: • Switch Positions 1 and 2 in the OFF position to select isolated horn and strobe power inputs • Switch Position 6 ON=HIGH dBA • Switch Position 6 OFF=LOW dBA Super Slide*Mounting Bracket Checkmate*Instant Allows the installer to pre-wire Voltage Verification the system,test for system It is often necessary to confirm the voltage supervision,remove the signal drop along a line of devices.The access head until occupancy,switch holes are provided in the back of the out signals without terminal block to allow the voltage to be changing mounting brackets measured directly without removing the and has locking edge connector device.Typically,this would be done at the for snap-in-place installation. end of line to confirm design criteria.Most �— measurements will be taken using the S+ and S-locations althouhg access is provided to other locations. NOTE:Care should be taken to not short the test probes. Candela selection slider switch. Depress center and slide switch to desire brightness level. �l t Break off pin and insert t s into hole at the bottom of ,s the selector to lock _� 99 candela setting.Signal 16 must be removed from y bracket and pin pushed forward from backside out of hole to change candela. To remove bezel,grip both sides of bezel and pull in a download and outward motion. PotterElectric Signal Company,LLC-St.Louis,MO 63042 USA•CustService:866-572-3005-Tech Support:866-956-0988•Canada 888-882-1833•wwwpottersignal corn PRINTED IN USA ►viFG.#8830054-REV A PAGE 2 OF 4 06/13 E) POTTER 5-24 & Hs-24 SELECTABLE CANDELA The Symbol of Protection STROBE &HORN/STROBES S-24 24 VDC Selectable Candela,Low Profile Evacuation Strobe Model Part Nominal Candela Number Number Voltage (ANSI/UL 1971) S-24WR 4890010 24 VDC 15,30,60,75, 110 S-24WW 4890011 24 VDC 15,30,60,75,110 HS-24 24 VDC Selectable Candela,Low Profile Evacuation Horn/Strobe Model Part Nominal Candela Reverberant dBA at In Anechoic Room Number Number Voltage (ANSI/UL 1971) 10 ft.,per ANSI/UL 464 dBA at 10 ft. HS-24WR 4890030 24 VDC 15,30,60,75,110 62-82 100 HS-24WW 4890031 24 VDC 15,30,60,75,110 62-82 100 S-24&HS-24 Product Strnhe Current Ratings(mA) 24 VDC(16-33 Volts) Model Designations: W=Wall Mount Candela 24 VDC UL Max R=Red Faceplate W=White Faceplate 15 cd 30 mA 42 mA 30 cd 35 mA 58 mA All units are available in plain(no lettering). Plain units are non-rehimahle. 60 cd 66 mA 97 mA 75 cd 80 mA 116 mA ALERT bezel available for order. 110 cd 103 mA 161 mA ALERT bezel available for order. S-24&HS-24 Product Horn Current Ratings Horn Decibel Levels Horn Current Ratings Minimum SPL Minimum SPL Regulated 24 VDC Horn Mode at 10 ft.,per at 10 ft.,per Max.Operating @ ANSI/UL 464 ANSI/UL 464 High Setting(mA) (HIGH) (LOW) Temp 3 2400 Hz 78 dBA 71*dBA 28 mA Temp 3 Mechanical 76 dBA 70*dBA 25 mA Temp 3 Chime 70*dBA 66*dBA 15 mA Continuous 2400 Hz 81 dBA 74*dBA 28 mA Continuous Mechanical 80 dBA 72*dBA 25 mA Continuous Chime 70*dBA 66*dBA 15 mA Whoop 82 dBA 69*dBA 56 mA NOTES: • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified]) power,see installation manual. • Potter does nto recommend usign a coded or pulsing signaling circuit with any of our strobe products. • The sound output for the temporal 3 tone is rated lower since the time the hom is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service.These settings are acceptable only for private mode fire alarm use.Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA•CustService:866-572-3005-Tech Support:866-956-0988•Canada 888-882-1833•wwwpottersignal.com PRINTED IN USA NEG.#8830054-REV A PAGE 3 OF 4 06/13 ' I E P0TT� 5-24 & H SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Architect&Engineering Specifications The audible and/or visible signal shall be Potter S-24 strobe and Potter HS-24 horn/strobe Series or approved equal and shall be listed by Underwriters Laboratories,Inc.per ANSI/UL 1971 and/or ANSFUL 464.The notification appliance shall also be listed with Factory Mutual Listing Service(FM)and the California State Fire Marshal(CSFM). The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater at 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage.The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control Control Panel signal signal Panel Signal Signal $. S+ S. H+ H- g. g. S. Hr H- Panel 8• S• H. H. s• s• s- H. H- Supervised Supervised I IS q S1B 0 0 0 Signal Circuit Signal Circuit \ \ O END LINE END OF LINE RESISTOR RESISTOR \ + EN11 OF LINE RCSI6TOR NOTES: • All strobes are designed to flash as specified with continuous applied voltage.Strobes should not be used on coded or pulsing signaling circuits.However,use of the Potter AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe,horn,and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION,REFERENCE AVSM CONTROL MODULE DATA SHEET(8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS.AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005-Tech Support:866-956-0988•Canada 888-882-1833•wwwpottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 4 OF 4 06/13 GENTEX CORPORATION GOE OUTDOOR ENCLOSURE Applications A C C E S S ® R 9 E S The Gentex GOE Outdoor Enclosure is ANSI/UL 464 listed for use in indoor and P A G E outdoor applications when used with the Gentex GEH Series horn and WGE /�1 Series strobe and horn/strobe. Standard Features • ANSI/UL 464 listed • Back box with side mount tabs • Made of clear Lexan®-providing maximum visibility and reliability • Unit Dimensions:5.75"(14.61 cm)high x 4.75" (12.10 cm)wide x 4.18"(10.62 cm)deep • 3/4"conduit knockouts • Reinforcement steel hardware • Outdoor resistant gasket • Available in red or off-white QOE-R GOE-W GOELP OUTDOOR ENCLOSURE Applications The Gentex GOELP Low Profile Outdoor Enclosure that creates a surface mount 1101 look, is ANSI/UL 464 listed for use in indoor and outdoor applications when used with the Gentex GEH Series horn and WGE Series strobe and horn/strobe. Standard Features • ANSI/UL 464 listed • Back box with outdoor resistant seal for mounting to wall GOELP GOE • Made of clear Lexan®-providing maximum visibility and reliability • Unit Dimensions:5.75"(14.61 cm) high x 4.75"(12.10 cm)wide x 3.25"(8.255 cm)deep • 3/4"conduit knockouts • Reinforcement steel hardware • Outdoor resistant gasket • Available in red or off-white GOE AND GOELP NOTES: • Product does not meet ANSI/UL 1971 light distribution requirements • To allow for drainage,the seal on the bottom edge is not water tight GOELP-R GOELP-W GBLP OUTDOOR BACK BOX Applications The Gentex GBLP Outdoor Back Box is constructed of durable plastic is ANSI/UL 464 listed for use indoor and outdoor applications when used with the WSSPK v c Series speaker and speaker/strobe. Standard Features • ANSI/UL 464 listed �.. • 1/2"conduit knockouts with metal washer reinforcement ► i • Wiremold knockouts for 500, 700 Series and pendulum mount • Unit Dimensions: 6.20"(15.75 cm)square x 2.04"(5.18 cm)deep • Reinforcement steel hardware GBLP-R GBLP-W • Outdoor resistant gasket • Available in red or off-white GSB SURFACE BACK BOX Applications The Gentex GSB Surface Back Box is constructed of durable plastic and is fully compatible with the Commander' (GE)and Commander'(GE3) Series horns, strobes and horn/strobes. Standard Features • ANSI/UL listed for indoor use • 1/2" conduit knockouts with metal washer reinforcement • Wiremold knockouts for 500 and 700 Series • Unit Dimensions: 5.57" (14.15 cm) high x 4.55" (11.56 cm) wide x 1.47" (3.73 cm) deep • Screw heads hidden GSB-R • Available in red or off-white ALERT & AGENT BEZELS Applications The Gentex ALERT and AGENT bezels are constructed of durable plastic and is A fully compatible with the Commander2(GE)and Commander'(GE3) Series horns, l strobes and horn/strobes. F Standard Features R • Easy to install • ALERT or AGENT wording on both sides of bezel • Available in red or off-white ALERT-W AGENT-R GCSB CEILING SURFACE BACK BOX Applications The Gentex GCSB Surface Back Box is constructed of durable plastic and is fully compatible with the Commander'(GC) Series strobes and horn/strobes. Standard Features III I • ANSI/UL listed for indoor use • 1/2"conduit knockouts with metal washer reinforcement • Wiremold knockouts for 500, 700 Series and pendulum mount • Unit Dimensions:6.2" (15.75 cm) round x 1.67"(4.24 cm)deep • Screw heads hidden • Available in red or off-white GCSB-R GCSB-W Important Notice' 551-0031-02 G E N T E X These materials have been prepared by Gentex Corporation eGentex l for informational andshould purposes only,are necessarily summary,and are not purported nt some as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these materiels CORPORATION are complele and accurate,up-to-date,or in compliance with all relevant local,slate and federal laws, regulations and rules.The materials do not address all legal considerations as there is inevitable Fire Protection Products Group•www.gentex.com uncertainty regarding interpretation of laws,regulations and rules and the application of such laws, regulations and rules le particular fact padems. Each person's activities can dill.mrilly affect the 10985 Chicago Drive •Zeeland, Michigan 49464 obligations that exist under applicable laws,regulations or rules.Therefore,these materials should be used only for informational purposes and should not be used as a substitute for seeking professional 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax legal advice.Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. Affordable Washington Backflow ..__ing BACKELOW PREVENTION ASSEMBLY TEST REPORT (360)863-3784 WATER PURVEYOR Arlington ACCOUNT# ASSEMBLY ID/FILE#/UTILITY DEVICE# Meter# NAME OF PREMISE Park 77 Commercial ❑ Residential ❑� SERVICE ADDRESS 20201 77th Ave NE Arlington ZIP 98223 CONTACT PERSON Yancy Constant PHONE (360) 384-4800 LOCATION OF ASSEMBLY Bldg D Right Side Fire Room DOWNSTREAM PROCESS Domestic DCVA ❑ RPBA W PVBA ❑ OTHER NEW INSTALL W EXISTING ❑ REPLACEMENT ❑ REMOVED ❑ OLD SER.# APPROVED ASSEMBLY? YES W NO ❑ PROPER INSTALLATION?YES W NO ❑ MAKE OF ASSEMBLY Conbraco/Apollo MODEL RPLF4A SERIAL NO. 816222 SIZE 2" INITIAL DCVA/RPBA DCVA/RPBA RPBA PVBA/SVBA TEST CHECK VALVE NOA CHECK VALVE NO.2 AIR INLET OPENED AT 2.2 PSID CLOSED TIGHT 0 CLOSED TIGHT W OPENED AT PSID PASSED LEAKED ❑ LEAKED El #1 CHECK 7.7 PSID FAILED ❑ TIGHT PSID TIGHT PSID AIR GAP OK? yes DID NOT OPEN ❑ CLEAN REPLACE PART CLEAN REPLACE PART CLEAN REPLACE PART CHECK VALVE NEW ❑ ❑ ❑ ❑ ❑ ❑ HELD AT PSID PARTS ❑ ❑ ❑ ❑ ❑ ❑ LEAKED ❑ AND ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ El El El El CLEANED REPAIRS REPAIRED ❑ TEST AFTER CLOSED TIGHT ❑ CLOSED TIGHT ❑ RV EXERCISED ❑ REPAIRS LEAKED ElLEAKED ❑ OPENED AT PSID AIR INLET PSID PASSED ❑ FAILED ❑ PSID PSID #I CHECK PSID CHK VALVE PSID AIR GAP INSPECTION: Required minimum air gap separation provided? YES ❑ NO ❑ Detector Meter Reading LEFT SERVICE AS FOUND Isolation valve: Open d❑ Closed ❑ SOV#1• Open W Closed ❑ SOV#2• Open ❑d Closed ❑ REMARKS: LINE PRESSURE 75 PSI CONFINED SPACE? No TESTERS SIGNATURE: CERT.NO. B6450 DATE 10/27/2017 TESTERS NAME PRINTED Jeff Hansen TESTERS PHONE# (360)333-2057 REPAIRED BY: LIC NO. DATE FINAL TEST BY: CERT. NO. DATE CALIBRATION DATE 04-25-2017 GAUGE 4 04172217 MODEL Midwest 835 SERVICE RESTORED YES W NO 0 ji FIRE PROTECTION BUREAU—PLAN REVIEW i PO Box 42600 + Olympia WA 98504-2600 ""`""°"""" '« (360)596-3911 FAX: (360)596-3934 � NFPA 13 SPRINKLER INSTALLATION CERTIFICATION Permit#: 1428-Building# [) Date: 10/19/2017 Property Protected System Installer System Supplier Business Name: Park 77 Apartments lUnlimited Mechanical Inc. HD Supply _ Address: 20227 77th Ave NE PO Box 1457 PO Box 1419 Arlington,WA. 98223 Marysville,WA. 98270 Thomasville GA 31799 Representative: Wayne Williams Telephone: 360-657-2182 Location of Plans: GC Office Location of Owner's Manual: Riser Room 1. Certification of System Installation: Complete this section after the system is installed, but prior to conducting operational acceptance tests. This system installation was inspected and found to comply with the installation requirements of: NFPA 13 IFC and IBC Manufacturer's Instructions Other(specify: FM, UL, etc.) Print Name: Wayne Williams Signed: 9. Date: 10/19/2017 Organization: Unlimited Mechanical, Inc. 2. Certification of System Operation: All operational features and functions of this system were tested and found to be ogprating properly in accordance with the requirements of: NFPA 13 IFC and IBC Manufacturer's Instructions Other(specify) Print Name: Wayne Williams Signed: � .�'��<�1<R-�"�:- Date: 10/19/2017 r Organization: Unlimited Mechanical, Inc. Sprinkler Information for Storage in 2002 NFPA 13, Chapter 12 and IFC Chapter 23 0 Automatic Sprinkler Systems FORM 2-1 Contractor's Material and Test Certificate for Aboveground Piping Date: 10/19/17 Property Name: Park 77 Apartments-D Property Address: 20227 77th Ave NE-Arlington, WA. 98223 Procedure Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and the system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authori- ties, owners, and contractors. It is understood that the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Plans Accepted by[approving authority's name(s)] City of Arlington Address 238 N Olympic Ave-Arlington, WA. 98223 Installation conforms to accepted plans? 0 Yes ❑ No Equipment used is approved? 0 Yes ❑ No If no, explain deviations. Instructions Has person in charge of fire equipment been instructed as to location of control valves and care and maintenance of this new equipment? Yes ❑ No If no, explain. Have copies of appropriate instructions and care and maintenance charts and NFPA 13 been left on premises? 0 Yes ❑ No If no, explain. Location of System Supplies building(s) Sprinklers Year of Orifice Temperature Make Model Manufacture Size Quantity Rating Tvco: TY2234 L,FII Res Rec Pend-White 3/8 231 155" Tvco: TY3331 1/2 54 155" Tvco: TY2234 FIR Rec p 3/8 130 175" Tvco: TY2334 LFII Res Rec SM-White 3/8 114 175' Pipe and Fittings Pipe conforms to NFPA 13 standard. 0 Yes ❑ No Fittings conform to NFPA 13 standard. Cl Yes ❑ No If no, explain. PAGE 1 of 3 Copyright©2000 National Fire Protection Association r - i � - i i � - Automatic Sprinkler Systems FORM 2-1 O Contractor's Material and Test Certificate for Aboveground Piping (coat.) Alarm Valve or Flow Indicator Alarm Device Maximum Time to Operate Through Test Pipe Type Make Model Min. Sec. Water Flow Potter VSR 30-45 Dry Pipe Operating Test Dry Valve Q.O.D. Make Model Serial No. Make Model Serial No. Time to Trip Trip Point Time Water Alarm Through Water Air Air Reached Operated Test Pipe* Pressure Pressure Pressure Test Outlet* Properly Min. Sec. Psi (Bar) Psi (Bar) Psi (Bar) Min. Sec. Yes No Without Q.O.D. With Q.O.D. If no, explain. Deluge and Preaction Valves Operation ❑ Pneumatic ❑ Electric ❑ Hydraulic Piping supervised? ❑ Yes ❑ No Detecting media supervised? ❑ Yes r l No Is there an accessible facility in each circuit for testing? ❑ Yes -1 No If no, explain. Does each circuit operate Does each circuit Maximum Time to supervision loss alarm? operate valve release? Operate Release Make Model Yes No Yes No Min. Sec. Test Description HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar)for two hours or 50 psi (3.4 bar) above static pressure in excess of 150 psi (10.2 bar)for two hours. Differential dry pipe valve clappers shall be left open during test to prevent damage. All aboveground piping leakage shall be stopped. FLUSHING: Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets such as hydrants and blow-offs. Flush at flows not less than 400 gpm (1514 L/min)for 4-in. (102-mm) pipe, 600 gpm (2271 L/min)for 5-in. (127-mm) pipe, 750 gpm (2839 L/min)for 6-in. (152-mm) pipe, 1000 gpm (3785 L/min)for 8-in. (203-mm) pipe, 1500 gpm (5678 L/min)for 10-in. (254-mm) pipe and 2000 gpm (7570 L/min)for 12-in. (305-mm) pipe. When supply cannot produce stipulated flow rates, obtain maximum available. *Measured from time inspector's test pipe is opened. PAGE 2 of 3 Copyright©2000 National Fire Protection Association � ' - �_ I FORM 2-i O Automatic Sprinkler Systems Contractor's Material and Test Certificate for Aboveground Piping (coat.) Test Description (cont.) PNEUMATIC: Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 11/2 psi (0.1 bar) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 11/2 psi (0.1 bar) in 24 hours. Tests All piping hydrostatically tested at 200+ psi (bar)for 2 hrs. Dry piping pneumatically tested? ❑ Yes ❑ No Equipment operates properly? ❑ Yes ❑ No If no, state reason. Drain test—Reading of gauge located near water supply test pipe: Static pressure: eZ psi (bar) Drain test—Residual pressure with valve in test pipe open wide: ._psi (bar) Underground mains and lead-in connections to system risers flushed before connections made to sprinkler piping Verified by copy of the U Form No. 85B 0 Yes ❑ No ❑ Other Flushed by installer of underground sprinkler piping 2 Yes ❑ No ❑ Other If other, explain. Blank Testing Gaskets Number used Locations N/A Number removed Welding Welded piping? ❑ Yes ❑ No If yes, Do you certify as the sprinkler contractor that welding procedures comply with the requirements of at least AWS D10.9, Level AR-3? ❑ Yes ❑ No Do you certify that the welding was performed by welders qualified in com- pliance with the requirements of at least AWS D10.9, Level AR-3? ❑ Yes ❑ No Do you certify that welding was carried out in compliance with a documented quality control procedure to insure that all discs are retrieved, that openings in piping are smooth, that slag and other welding residue are removed, and that the internal diameters of piping are not penetrated? ❑ Yes ❑ No Hydraulic Data Nameplate Nameplate provided? 0 Yes ❑ No If no, explain. Remarks Date left in service with all control valves open: Sprinkler Contractor: Unlimited Mechanical, Inc. Signatures of Test Witnesses For property owner(signed) Title Date For sprinkler contractor(signed) '�zcyLw �c.��''���" Title President _ Date 10/19/17 PAGE 3 of 3 Copyright©2000 National Fire Protection Association i i i i i ii - i + ra i Park 77 20227 77th Ave NE See Master File BLD-1070 for complete submittal. 9 A 91 S O o0 M eh C O C"IllL� O M Ci C i rN� O O d� N N bD y C11 0 O� N \0 N \Q g m q \0 Lq N O N N N \0 H N N 00 N di N 00 N 4 N N 4" r-4 rr-I �O� M e-ar-4r~ " r-i r 4 t!3 ['r) r-+ r-4 r-I r� N rti r-I Cl1 !V t!? d3 ER } Efl ft3 H? WR t M � H3 tR Wf WR t 3 t 4 d4 tf3 W O O O O O O O O O O O O O O O O O O O O O O O O O O O O S O O O O O O O O S + lV cv� R W �N � O, m O� t � L\d� mN L\d� m d� L\di m ,S4 cf tl cr] K c� c$ l� rl n a 00 Cl) c� c� t, [ri ch t, erg r-4 r-4 r-I r-4 r~ r� r-4 r 4 In r-i r~ r-I r-I r-4 r-4 r-4 UtF3 t0 to is to V�. &3 tR q)- � 05. 0) ti3 to Vf V)- t� Ntl3 00 00 N 00 \0 N 00 N 00 N 00 00 N 00 0J M M r~ M 00 � � " m fn tr] n (r7 m L� O S wO� l!] O� lf� r- O\ In 1n ID O� rti m In m m Ill O Ln yy k n k n 9 r R, n n 6 n n N r~ Il') r~ IA O �-i L lfi L f7 pppp ti O Pd L rti r-1 In Off\ 00 EtC4 r4 r-4 r-1 r� N r r-4 � r-I ift eq r-+ N r-I r-4 r� r-o rq 01 e7 � ER tf3 tR tf? tR &3 t!3 t!3 ts3 ri tR t!3 t!3 t13 to tA- tf3 V? lV rr 03. E!3 � ON ti eN-4 M O O� O\ N O� T a0 O F 0 M N LM N In lO N In In In M N �0 N In N N In N Q�r N CD00 � Lo rr � r♦ w {�tp� O O O S In mCDZ m O O l� In 0 0 0 0 " n " L N M " d! t� M L� "I rLn r ti rr-1 M r oc� 0.1 O� 4 e� Gr rw .O v Q pq N � � a�a im c�\ T '. �n ci o N N F 1114 12 o r+ N frm d� In \O ° In O� .� r~ r~ U Qr QI N Date: 04/03/2026 Permit#: 1189 Perm Date: 10/24/2016 Review Date: 10/24/2016 Perm Type: FIRE ALARM Review Type: FIRE ALARM Target Date: 11/07/2016 Scheduled Time 00:00 Com pleted Date: 11/08/2016 Description: Ok to issue Review Status: Assigned To: z.Christopher Young Tim eln: 00:00 Time O it: 00:00 H curs: 0.0 Property Information PDrcel#: 00829100000103 W ARLINGTON INVESTMENT LLC WDARLINGTON INVESTMENT LLC 1 020 WEST CASINO RD 20227 77th Avenue NE E VERETT,WA98204 Zoning: 910 Undeveloped (Vacant) LandLot: Block: jari@william anvest.com Permit#: 1189 Permit Date: 10/24/16 Permit Type: FIRE ALARM Project Nam e Park 77 Applicant Nam a Fire Protection, Inc. Applicant Address: 1730 Gibson Road Applicant, City, State, Zip: Everett,WA98204 Contact: David Mow Phone: 425-290-9600 Em al: david@fpiseattle.com Scope of Work: Apartm olts Valuation: 3500.00 Square Feet: 0 Num ber of Stories: 0 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 11/16/2016 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Launa Black Property Parcel# Address L egal Description O wrier Nam e Caner Phone Zoning 00829100000103 2 0227 77thAvenue NE WDARLINGTON 910 Undeveloped INVESTMINT LLC (Vacant)Land Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# FIRE PROTECTION David Mow 4 25-290-9600 1 730 Gibson Rd CONSTRUCTION UBI 601 848 346 INC CONTRACTOR FIRE PROTECTION CONSTRUCTION Labor and INC David Mow 4 25-290-9600 1 730 Gibson Rd CONTRACTOR Industries FIREPI*021ML Inspections Date I nspection Type D escription S cheduled Date C om lieted Date I nspector S tatus 10/23/2017 FA00.FIRE ALARM Building D-9 Fire alarm 10/19/2017 B UILDING C om Oeted FINAL com Bete&arm a1. Plan Reviews Date Review Type D escription A ssigned To R eview Status 10/24/2016 FIRE ALARM O k to issue z.Christopher Young Attached Letters Date Letter D escription 11/10/2016 Building Perm i Notes Date Note C reated By: 09/01/2017 Bldg.#9 Kristin Foster 11/08/2016 See Master Fire Alarm Perm i#1194(Phase I)for fees.This perm i contains Type A units. C hris Young Uploaded Files Date File Nam e 11/16/2016 1953061-1189 Issued Perm i.pdf 10/24/2016 190973649 Fire Specs Part2.pdf 10/24/2016 190973749 Fire Alarm Perm i Application CgZBBm QTIbzKON.pdf 10/24/2016 190973849 Fire Specs Partl.pdf