Loading...
HomeMy WebLinkAbout3229 179TH ST NE_BLD1164_2026 I CITY OF ARLINGTON 238 N. OLYMPIC AVE- ARLINGTON,WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:3229 179th Street NE Permit#:1164 Parcel#:00621300005700 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:GILLIS JULIA G Name:Blue Flame Heating and Air Name:BLUE FLAME HEATING AND AIR Address:3229 179TH ST NE Address:71 l6 220th Street SW,#1 Address:7116 220 ST SW City,State Zip:ARLINGTON,WA 98223-6313 City,State Zip:Mount Lake Terrace,WA 98043 City,State Zip:MOUNTLK TERRACE,WA 98043 Phone: Phone:425-771-7139 Phone:425-771-7139 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:BLUE FLAME HEATING AND AIR Name: Address:7116 220 ST SW Address: City,State,Zip:MOUNTLK TERRACE,WA 98043 City,State,Zip: ! Phone:425-771-7139 Phone: LIC#:BLUEFFH865JB EXP: 4/2/2018 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: ] OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI l0/IRCI 10. SAL :Sales tax r Ieting to construction and construction materials in the City of Arl(pilton must be reported on your sales tax return r and co ed i of Arlington O1.I l / u 'D f') / /vtt/v I �n Si afore Print Name Date Relcased By Date CONDITIONS Rheem R801 S-AFUE 80%-APPROVED AS 8UBMITTED THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/11/2016 Fumace $25.00 10/11/2016 Mechanical Permit Base Fee $25.00 Total Due: $50.00 Total Payment: $0.00 Balance Due: $50.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,TI pe of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:3229 179th Street NE Permit#• 1164 Parcel#:00621300005700 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:GILLIS JULIA G Name:Blue Flame Heating and Air Name:BLUE FLAME HEATING AND AIR Address:3229 179TH ST NE Address:7116 220th Street SW,#1 Address:7116 220 ST SW City,State Zip:ARLINGTON,WA 98223-6313 City,State Zip:Mount Lake Terrace,WA 98043 City,State Zip:MOUNTLK TERRACE,WA 98043 Phone: Phone:425-771-7139 Phone:425-771-7139 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:BLUE FLAME HEATING AND AIR Name: Address:7116 220 ST SW Address: City,State,Zip:MOUNTLK TERRACE,WA 98043 City,State,Zip: Phone:425-771-7139 Phone: LIC#:BLUEFFH865JB EXP: 4/2/2018 LIC#: EXP: JOB DESCRIPTION _ PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL _ I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1I OARC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arli ton must be reported on your sales tax return form and coded City of Arlington#3101. LOA14�-, Signature Print Name Date V Released By Date CONDITIONS Rheem R801 S -AFUE 80% -APPROVED AS WBMITTED THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/11/2016 Furnace $25.00 10/11/2016 Mechanical Permit Base Fee $25.00 Total Due: $50.00 Total Payment: $0.00 Balance Due: $50.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon BUILDING INSPECTION REPORT — MECHANICAL (RESIDENTIAL) Permit No. 1164 Address: 3229 179th Street NE Contractor: Blue Flame Heating and Air Owner: Gillis Date: 10/31/2016 ® APPROVAL ❑ PARTIAL APPROVAL ❑ CORRECTION ❑ OTHER APPLIANCE: Gas Furnace CO DETECTOR: N HEAT PUMP/AC UNIT: ❑ GAS PIPING: N DISCONNECT: ❑ DRIP LEG: ❑ SEISMIC: N VENTING: N 3" PAD: ❑ ACCESS: N INSULATION/PROTECTION: ❑ SHUT-OFF VALVE: N DUCTS: N/A L&I: Yes Date: 10/31/2016 Inspector: Kevin Olander ° CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON,WA. 98223 PHONE; (360)403-3551 BUILDING PERNIIT Address:3229 179th Street NE Permit#:1164 Parcel#:00621300005700 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:GILLIS JULIA G Name:Blue Flame Heating and Air Name:BLUE FLAME HEATING AND AIR Address:3229 179TH ST NE Address:7116 220th Street SW,#1 Address:7116 220 ST SW City,State Zip:ARLINGTON,WA 98223-6313 City,State Zip:Mount Lake Terrace,WA 98043 City,State Zip:MOUNTLK TERRACE,WA 99043 Phone: Phone:425-771-7139 Phone:425-771-7139 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:BLUE FLAME HEATING AND AIR Name: Address:7116 220 ST SW Address: City,State,Zip:MOUNTLK TERRACE,WA 98043 tatty,State,Zip: Phone:425-771-7139 Phone: LIC#:BLUEFFH865JB EXP: 4/2/2018 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES, CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMENS COMPENSATION INSURANCE AND RCW 19.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI l0/IRCI 10. * jQF,: Sales tax r lilting to construction and construction materials in the City of Arliagion must be reported on your sales tax return r and co ed 40 of Arlington O1. �c,i�G�«ot �Zu Vl L J/(�1 I St uture Print Name Date Released By Date CONDITIONS Rheem R801S -AFUE 80%-APPROVED AS SUBMITTED THIS PERMIT AUCHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/11/2016 Furnace $25.00 10/11/2016 Mechanical Permit Base Fee $25.00 Total Due: $50.00 Total Payment: $0.00 Balance Due: S50.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:3229 179th Street NE Permit#: 1164 Parcel#:00621300005700 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:GILLIS JULIA G Name:Blue Flame Heating and Air Name:BLUE FLAME HEATING AND AIR Address:3229 179TH ST NE Address:7116 220th Street SW,#1 Address:7116 220 ST SW City,State Zip:ARLINGTON,WA 98223-6313 City,State Zip:Mount Lake Terrace,WA 98043 City,State Zip:MOUNTLK TERRACE,WA 98043 Phone: Phone:425-771-7139 Phone:425-771-7139 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:BLUE FLAME HEATING AND AIR Name: Address:7116 220 ST SW Address: City,State,Zip:MOUNTLK TERRACE,WA 98043 City,State,Zip: Phone:425-771-7139 Phone: LIC#:BLUEFFH865JB EXP: 4/2/2018 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arli ton must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By Date CONDITIONS Rheem R801 S -AFUE 80% -APPROVED AS WBMITTED THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/11/2016 Furnace $25.00 10/11/2016 Mechanical Permit Base Fee $25.00 Total Due: $50.00 Total Payment: $0.00 Balance Due: $50.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon RLSIDENTIAL MECH#4NICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE- Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:3229 179TH ST NE ARLINGTON, WA 98223 Project Description:LIKE IN KIND FURNACE REPLACEMENT Owner: JULIE GILLIS Address: 3229 179TH ST NE City:ARLINGTON State WA Zip Code: 98223 Phone: 360-631-2191 Email:INFO@BLUEFLAMECOMFORT.COM Applicant: KAILANA MONIZ Address:7116 220TH ST SW#1 City: MOUNTLAKE State WA Zip Code: 98043 Phone: 425-771-7139 Email: INFO@BLUEFLAMECOMFORT.COM CONTRACTOR INFORMATION Contractor Name:BLUE FLAME HEATING AND AIR Address:7116 220TH ST SW#1 City: MOUNTLAKE State.WA Zip Code: 98/043 License Number:BLUEFFH865JB Expiration: 04/02/18 Phone:425-771-7139 Email:INFO@BLUEFLAMECOMFORT.COM RA ocr r d STAFF USE ONLY 0 2016 Permit #: Accepted by: Date: 6/16LP Page 1 of 2 RLSIDENTIAL MECH#4NICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES [Vjj Furnace (80+) Model #R801 SA050314ZSA AFUE80 Heat Pump Model # AFUE HSPE AC Unit Model # SEER Freestanding Stove CI; Fire Place Insert ❑i Outdoor BBQ g Gas Piping 0: Solid-Fuel Appliance D Other Gas Piping Information Not Applicable: , Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: " Date: 10/10/2016 Applicant Printed Name: KAILANA MONIZ I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 Gas Furnaces Air R8O1S(DF)Series / 1 I The new degree of comfort'" Rheem Classic®Series Downflow Gas Furnace ew�#Iav Series 00'a A.F.U.E.t — Input Rates 50-150 kBT tA.F.U.E.(Annual Fuel Utilization Efficiency)calculated in accordance with Department of Energy test procedures. t 1 ' • 80% residential Gas Furnace CSA certified • Low profile 34" cabinet ideal for space constrained installations • PlusCine-Diagnostics — 7 Segment LED all units • Integrated Control board features dip switches for easy • PlusCine-Ignition System-DSI for reliability and longevity system set up • Heat exchanger is removable for improved serviceability. . QR code for quick access to product information from your Aluminized steel construction provides maximum corrosion smart phone or tablet resistance and thermal fatigue reliability. Received OCT 10 2016 �D - III FORM NO.G11-647 REV.1 --D' Air Table of Contents 7 1 R801S(DF)Series TABLE OF CONTENTS Standard&Optional Equipment ......................................................................3 Model Features/Physical Data&Specifications..................................................4 Model Number Identification............................................................................5 DimensionalData............................................................................................6 Blower Performance Data................................................................................7 Accessories....................................................................................................8 LimitedWarranty ............................................................................................9 COMFORTINTEGRATED HOME 'f1 Air Standard&Optional Equipment R801 S(DIF)Series ilulni HEAT EXCHANGER — ff INTEGRATED FURNACE CONTROL i DRAFT INDUCER MOTOR - l DIRECT SPARK IGNITOR WITH REMOTE SENSE - IN-SHOT BURNERS 001 STANDARD EQUIPMENT OPTIONAL EQUIPMENT Completely assembled and wired;induced draft; pressure NOTE: Furnace is not listed for use with fuels other than switch;redundant main gas control;blower compartment door natural or L.P. (propane)gas. safety switch;solid state time on/time off blower control; limit The complete terms of limited and other warranties are control; manual shut-off valve, pressure regulator for natural available at our sales office,or through local installer. and L.P.(propane)gas;transformer;direct drive multi-speed All models can be converted by a qualified Rheem distributor blower motor. Furnaces are equipped with cooling/heating or local service dealer to use L.P. (propane)gas without relay and transformer(40VA)ready for air conditioning applications.(Please note:a thermostat is not included as changing burners. Factory approved kits must be used to board convert from natural to L.P. (propane)gas and may be ordered standard equipment.) Flame sensor diagnostics; ud twinning;fused-protection(secondary),3rd speed option for as optional accessories from a Rheem parts distributor. continuous fan;common heat/cool terminal. For L.P.(propane)operation,refer to Conversion Kit Index Form. NOTE: For natural and L.P.(propane)gas models, direct spark ignition is 100% lockout type. WARNING �IS NOTACPROvED •' FE0CMMH4DBD •' USE IN NACSLE • ES INTEGRATED HOME •- �. Model Features/Physical Data&Specifications Air R801S(DF)Series Model Features • 80% residential Gas Furnace CSA certified • Low profile 34" cabinet ideal for space constrained installations • PlusOne'"Diagnostics - 7 Segment LED all units . Blower shelf design-serviceable in all furnace orientations • PlusOne'" Ignition System-DSI for reliability and longevity . Integrated Controls board features dip switches for easy • Heat exchanger is removable for improved serviceability. system set up Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability. smart code for quick access to product information from your smart phone or tablet Physical Data and Specifications U.S.and Canadian Models MCDB_NUMBERS R801SA R801SA M01SA R801SA R801SA R801SA R801SA R801SA R801S(DOAWLCR 050314ZIA 075317Z'A 075417ZIA 100317ZA 100421Z`A 100521ZIA 125524Z*A 150524Z"A Inputs Ull-t[kW]TO 50,000[15] 75,000 [22] 75,000 [22] 100,000[29.31 100,000[29.3] 100,000[29.3] 125,000[36.61 150,000 [44] Heating Capacity S U/Ft[kW]T 41,000[12] 60,500 [18] 60,500 [18] 80,000 [23] 80,000 (23] 81,000 [24] 99,000 [29] 120,000 [35] Figh Altitude Input[kW] 45,000[13] 67,500[19.8] 67,500[19.8] 90,000[26.41 90,000[26.41 90,000[26.4] 112,500 [331 135,000[39.6] Figh AltitudeQitput 36,500[10.7] 54,000[15.8] 54,000[15.8] 72,000[21.1] 72,000[21.1] 72,500[21.2] 89,000[26.1] 107,500[31.5] Capacity[MM Heat Bd.Static Pressure[kN] .10[.025] .12[.029] .12[.029] .15[.037] .15[.037] .15[.037] .20[.05] .20[.051 Blower(DxW[mm] 11x6 11x6 11x7 11x7=10'AM 11x10 11x10 11x10 11x10 [279 x 152] [279 x 1521 [279 x 178] [279 x 1781 [279 x 254] [279 x 254] [279 x 254] [279 x 254] Motor RR[W]-Sqoeeds[W]- 1/2-4-PSC 112-3-PSC 314-3-PSC 1/2-3-PSC 1/2-3-PSC 3/4-3-PSC 3/4-3-PSC 3/4-3-PSC PSCType [373] [373] [5591 [3731 [373] [559] [559] [5591 Motor Full Load Amps 6.8 5.8 9.5 7.1 7.9 9.5 9.5 9.5 Heating Speed LON MEDIUM LON M® MED LOR LOAN LON Cooling Speed F*GH FIG-1 F IGH F IGH HI -1 1-11113H FIG-1 FIG-1 Coding CFM @.5"[kPa]ES.P. 1200 1200 1600 1200 2000 2000 2000 2000 (Nominal)[Us] [566] [566] [755] [566] [9441 [944] [944] (9441 Rated ES.P.(in.1l Q)[kPa] 0.5[.12] 0.5[.12] 0.5[.12] 0.5[.12] 0.5[.121 0.5[.12] 0.5[.12] 0.5[.12] Temperature Pose Range°F 25-55 30-60 25-55 45-75 40-70 40-70 40-70 50-80 ['Cl [13.9-30.6] [16.7-33.3] [13.9-30.61 [25-41.7] (22.2-38.91 [22.2-38.9] [22.2-38.9] [27.8-44.4] Mao(.Cutlet Air Temp.°F 155 165 155 190 190 170 180 170 [,q [68.3] [73.9] [68.3] [87.8] [87.8] [76.7] [82.2] [76.7] Approx.Shipping Weight(Lbs.) 85 105 105 115 120 120 140 150 [kg] [38.6] [47.6] [47.6] [52.2] [54.4] [54.4] [63.5] [68.0] AR1E-Bec tric Ignition Models O 1 80% 80% 80% 80% 80% 80% 80% 80% NOTES All models are 116\{60F7,12l Gas oonnecticn sim far all models is W'NPT. T In aocardancewith 110E test procedures. s0 See 03wersion At Index Form for high altitude derate in US applications. [ ]Designates Metric Conversions COMFORTINTEGRATED HOME Air Mcd•ei Number Identification R801S(DF)Series Model Number Identification—Downflow Models R 80 1 S A 075 4 17 Z S A Rheem 80= 1=Single Stage S=Standard Design Series I nput 3=Up to Cabinet Z=Down X=Low N0x Revision- 80%AFLE PSC A=1st Design 6TU/FR 3 Ton Wdth and Zero S=Standard Marketing 050= 50,000[15] 4=Up to 14=14" aearanoe (A—First Time 075= 75,000[22] 4 Ton 17=17.5' Downflow Release) 100=100,000[29] 5=Up to 21=21" 125=125,000[37] 5 Ton 24=24.5" 150=150,000[44] [ ]Designates Metric Conversions INTEGRATED HOME COMFORT Air' Dimensional Data . 0 R801S(DF)Series Downflow Dimensions 7/16" TOP BOTTOM 111 mml RETURN SUPPLY 19'+ 24112' Aii AIR 1502 mml 16V mm1 L L � C E A [19 mm] � 281he"1713 mm] m R.A. 20Ve' We' B --�[ e/e"[16 mm] D [ �e�511 mm] (18 mml I —7[ 6 mm[ 79M MIS.1675 mml IW DIA.[13 mml [676 mm] I W DIA. 1 LOW VOLTAGE 7 [22 mml COELECTRICAL GH VOLTAGE)�NNECTION / I [864 mm] 23�' p p 2331e' I 2813/is. [584 mml 1594 mml [681 mml °� IIII 24rhe" [518 mm) 2031e" (621 mm] MI [518 mm] GAS CONNECTION 63/,e" 6311e' 13/s'DIA. 1157 mm] �— [157 mm] [35—1 LEFT SIDE FRONT RIGHT SIDE Dimensions and Clearance to Combustible Material (inches) [mm] MCDE- FEDLUD CLEARANCES(IR)[mm] R801S A B C D E [gT FZJGff SHP.V167S. ( 6M SIDE SIDE BACK TCP FRCN[T V9VT (LB5)[k9] SER050 14 [356] 1227/32[326] 103/e[264] O 131/6[333] 0 42 0 1[25] 3[76] 6[152]03 85[38.6] 075 171/2[445] 1611/32[415] 121/8[308] 1p 165/e[422] 0 30 0 1[25] 3[76] 6[152]03 105[47.6] 100317 171/2[445] 1611/32[415] 121/6[308] ip 165/6[422] 0 30 0 1[25] 3[76] 6[152]03 115[52.2] 100421 21 [533] 1927/32[504] 137/6[352] iD 201/e[511] 0 0 0 1[25] 3[76] 6[152]OO 120[54.4] 100521 125 241/2[622] 2311/32[593] 155/e[397] iD 235/6[600] 0 0 0 1[25] 3[76] 6[152]( 140[63.5] 150 241/2[622] 1 2311/32[593] 1 155/8[397] 1 i0 235/8[600] 0 0 0 1[25] 3[76] 6[152]OO 150 [68] MOTES O May require a 3"[76 mm]to 4"[102 mm]or 3"[76 mn]to 5'[127 mm]adapter. 02 May be 0"[0 mm]with type B vent. 03 May be f(25 mm]with type B ver t. Furnaces must be vented in accordance with the National Fuel Gas Code,ANSI Z223.1 and in accordance with local codes. [ ]Designates Metric Conversions Air Blower Performance Data 0 I R801S(DF)Series Blower Performance Data—Downflow Models MCDEL ELCIAER MOTOR CFM[Us]AIR DELIVERY RBOISDR SIZEOP BLOJVfft WrEINAL STATIC PRESR1RE INU ES[kPa]WATER CCLUNN �1IS [mm] [W] SPEED 1[.02] .2[.05] .3[.07] .4[.10] .5[.12] .6[.151 .7[.17] LOW 735[347] 715 [337] 690 [326] 660 [311] 635 [300] 605 [286] 575[271] 050 11 x 6 1/2 MB)-LO 1025[484] 1015 [479] 995 [470] 975 [460] 955 [451] 930 [439] 905[427] [279 x 152] [373] MED•1-1 1185[559] 1165 [550] 1150 [543] 1130 [533] 1100 [519] 1075 [507] 1040[491] FIGH 1345[635] 1330 [628] 1310 [618] 1295 [611] 1265 [597] 1235 [583] 1205[569] 11x6 1/2 LOW 1104[529] 1081 [510] 1050 [496] 1025 [484] 999 [471] 971 [458] 940[444] 075317 [279 x 52] [373] MED 1284[606] 1269 [599] 1236 [583] 1206 [569] 1179 [556] 1139 [538] 1102[520] FIG-1 1478[698] 1438 [679] 1397 [659] 1362 [643] 1392 [657] 1282 [605] 1242[586] 11x7 1/2 LOW 1210[571] 1205 [569] 1195 [564] 1180 [557] 1165 [550] 1155 [545] 1130[533] 075417 [279 x 178] [3 3] MED 1580[746] 1560 [736] 1550 [732] 1530 [722] 1495 [706] 1465 [691] 1430[675] FIC+i 1915[904] 1880 [887] 1825 [8611 1790 [845] 1740 [821] 1675 [791] 1600[755] 11x7 1/2 LOW 1070[505] 1055 [498] 1040 [491] 1010 [477] 980 [463] 945 [446] 905[427] 100317 [279 x 178] [373] MED 1240[585] 1210 [571] 1190 [562] 1165 [550] 1135 [536] 1095 [517] 1055[498] FIG-1 1420[670] 1395 [658] 1370 [647] 1340 [632] 1305 [616] 1265 [5971 1220[576] 11X10 1/2 LOW 1303[615] 1304 [615] 1280 [604] 1250 [590] 1222 [577] 1188 [5571 1160[547] 100421 1279 x 2541 [33] MED 1697[801] 1674 [790] 1655 [781] 1638 [773] 1621 [765] 1581 [7461 1542[728] FIG-1 2O78[981] 2068 [976] 2037 [961] 2010 [9491 1988 [938] 1938 [915] 1898[896] lIX10 3/4 LOW 1690[798] 1670 [788] 1655 [781] 1615 [762] 1585 [748] 1565 [739] 1525[720] 100521 1279 x 254] [559] MED — 2085 [984] 2055 [970] 2005 [946] 1970 [9301 1945 [918] 1880[887] FIG-1 — 2410[1137] 2355[1111] 2305[1088] 2240[1057] 2165[1022] 2100[991] LOW — 1690 [798] 1660 [783] 1635 [772] 1580 [746] 1535 [724] 1480[698] 125524 [279 x 254] [559] MED — 2090 [986] 2035 [960] 1985 [937] 1930 [911] 1850 [873] 1785[842] FIG-1 — 2395[1130] 2335[1102] 2260[1067] 2185[1031] 2080 [982] 1965[927] LOW 1675[791] 1650 [779] 1620 [765] 1570 [741] 1545 [729] 1485 [701] 1425[673] 150524 11 x 10 3/4 MED 2105[993] 2075 [979] 2035 [960] 1990 [939] 1955 [923] 1900 [897] 1815[857] [279 x 2541 [559] FIG-I — — — — — — NOM fbarnrrended dower speeds are in bdd. [ ]Designates Metric Conversions OME COMFORT Air Accessories , 0 R801S(DF)Series DOWNFLOW ACCESSORIES DOWNFLOW WARNING:Unit design is certified for installation on GXGP-F03 non-combustible floor.A special factory supplied combustible PARALLEL FURNACE KITS—are for parallel operation requirements, floor sub-base is required when installing on a combustible floor.Failure to install the sub-base may result in fire,property damage and personal injury. RXGF-CC* FILTER RACK—Davnflow top return rnou nL Ibguires(2)14 x 20 filters. COMBUSTIBLE FLOOR BASE DIMENSIONS NOTE: Filter racks are shipped without filters COMBUSTIBLE USEwIhI A B C *Filters availablethrough PFCSTC)CKO. FLOCR BASE FUR AC'FSIZES IR [mm] IR[mm] IR[mm] RXOGB14 801 SO50 141/2[368] 131/4[337] 111/4[286] RXOGB17 801 S075,801 SA1 00317 18 [4571 163/4[4251 143/4[4511 RXGF-DB* RXOGB21 801 SA100421, 211/2[5461 201/4[514] 181/4[4641 Each order contains(1)one box of 10 filter racks supplied without filters 801SA100521 _ RXOGB24 801S125,801S150 25 [635] 233/4[603] 213/4[552] *Filters a�raladethraJgh TO�C'. FOR HIGH ALTITUDES: 191'e 1496 mmi HIGH ALTITUDE OPTION CODE: US— -� [None required for high altitudes. HIGH ALTITUDE CONVERSION KITS: US— c None required for high altitudes. 80+HIGH ALTITUDE INSTRUCTIONS I- >>r.• 1-p.� r vT- Caution:Plways fdlav National FA Gas Code(NFL guidelines �^[184 mm1 �;: when converting for high altitudes 1721 mm1 A Hgh altitude option codes are not required for these models `L H7uveveer,the burner orifice size needs to be recalculated and verified FIBERGLASS I25 mml ak el�ions above 2000 ft.See Installation Instructions far more �� s ,,t 3 LB.11.4k91 o NSITV I 1178 mm1. 1 FIBERGLASS InfOn'T1ati0n• (51 mmi 2" 3 I.B.(1 41 1 0ENSRV nOOR t-PLENUM OR IT - 3.178 mm1 DUCTWORK [ ]Designates Metric Conversions L21 r:" ILF B M" U NOTE:FLOOR OPENING 21-h"150 MITI]x5 MAX.PLENUM SIZE W W 1495 mm1 x C __0 INTEGRATED HOME COMFORT Air Limited Warranty 0 RSOtS(DF)Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Heat Exchanger ......................................Twenty(20)Years which fails in normal use and service within the applicable Conditional Parts(Registration Required)........Ten(10)Years period stated, in accordance with the terms of the limited warranty. "For complete details of the Limited and Conditional Warranties, including applicable terms and conditions,contact your local contractor or the Manufacturer for a copy of the product warranty certificate. INTEGRATED HOME COMFORT Air 1 Notes 0 R801S(DF)Series 10 INTEGRATED • • •- 'f1 Air Notes 0 RBO1S(Di7 Series 11 INTEGRATED • • •- The new degree of comfort' In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Heating,Cooling&Water Heating • P.O.Box 17010 Rheem Canada Ltd./Ltee • 125 Edgeware Road,Unit 1 Fort Smith,Arkansas 72917 • www.rheem.com Brampton,Ontario • L6Y 0135 INTEGRATED HOME COMFORT PRINTED IN U.S.A 7/14 OG FORM NO.G11-547 REV.1 Permit#: 1164 Permit Date: 10/10/16 Permit Type: RESIDENTIAL MECHANICAL Project Name Gillis Applicant Nam a Blue Flam eHeating and Air Applicant Address: 7116 220th Street SW,#I Applicant, City, State, Zip: Mount Lake Terrace,WA98043 Contact: Kailana M oniz Phone: 425-771-7139 Em al: info@blueflam xom firt.com Scope of Work: Replace Gas Furnace Valuation: 0.00 Square Feet: 0 Num ber of Stories: 0 Construction Type: O xupancy G ioup: ID Code: Permit Issued: 10/11/2016 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Launa Black Property Parcel# Address L egal Description O wner Nam e Ovner Phone Zoning 00621300005700 3 229 179TH ST NE G ILLIS JULIA G 111 Single Fam iy Residence-Detached Contractors Contractor P rim ay Contact P hone A ddress C ontractor Type L icense License# BLUE FLAME RODNEY CONSTRUCTION HEATINGANDAIR WALKER CONTRACTOR 425-771-7139 7 116 220 ST SW COA 601 837 949 BLUE FLAME RODNEY CONSTRUCTION Labor& BLUEFFH825RM HEATING AND AIR WALKER 425-771-7139 7 116 220 ST SW CONTRACTOR Industries Inspections Date I nspection Type D escription S cheduled Date C om lieted Date I nspector S tatus CIO. Furnaces were operating and 12/19/2016 MECHANICAL balanced.All diffusers,fans, 12/19/2016 1 2/19/2016 z.Christopher Young A pproved ROUGH-IN and return air functioning. C10. 10/31/2016 MECHANICAL 10/31/2016 A pproved ROUGH-IN Fees Fee D escription N otes A m cant Forced Air Heat f ee per Btu $25.00 Mechanical Base P erm i Fee $25.00 Total $50.00 Attached Letters Date Letter D escription 10/11/2016 Building Perm i Paym eats Date Paid By D escription P aym elt Type A ccepted By A m cunt 10/11/2016 KAILANAMONIZ 6 1806634 c c $50.00 O ttstanding Balance $0.00 Notes Date Note C reated By: 10/10/2016 Rheem R801 S-AFUE 80%L auna Black Uploaded Files Date File Nam e 11/03/2016 1931886-3229 179th Street NE.docx 10/11/2016 1886159-1164 Issued Perm i.pdf 10/10/2016 1884304-Residential Mechanical CgE2oHOGOZ4aRe.pdf 10/10/2016 1884305-ResMech Specs.pdf RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:3229 179TH ST NE ARLI NGTON, WA 98223 Project Description:LIKE IN KIND FURNACE REPLACEMENT Owner: JULIE GILLIS Address. 3229 179TH ST NE City. ARLINGTON State YVA Zip Code: 98223 Phone. 360-631-2191 Entail:INFO@BLUEFLAMECOMFORT.COM Applicant: KAILANA MONIZ Address: 7116 220TH ST SW#1 City. MOUNTLAKE State WA Zip Code: 98043 Phone. 425-771-7139 Email. INFO@BLUEFLAMECOMFORT.COM CONTRACTOR INFORMATION Contractor Name:BLUE FLAME HEATING AND AIR Address: 7116 220TH ST SW#1 City: MOUNTLAKE State WA Zip Code: 98/043 License Number: BLUEFFH865JB Expiration: 04/02/18 Phone:425-771-7139 Email:INFO@BLUEFLAMECOMFORT.COM STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #R801 SA050314ZSA AFUE80 ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: [El Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date: 10/10/2016 Applicant Printed Name: KAILANA MONIZ I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 Air Gas Furnaces ' D R801S(DF)Series The new degree of comfort:" Rheem Classic'Series Downflow Gas Furnace R801 S (Downflow) Series 80% A.F.U.E.t Input Rates 50-150 kBTU tA.FU.E.(Annual Fuel Utilization Efficiency)calculated in accordance with Department of Energy test procedures. I • 80% residential Gas Furnace CSA certified • Low profile 34" cabinet ideal for space constrained installations • PlusOne—Diagnostics — 7 Segment LED all units • Integrated Control board features dip switches for easy • PlusOne—Ignition System-DSI for reliability and longevity system set up • Heat exchanger is removable for improved serviceability. . QR code for quick access to product information from your Aluminized steel construction provides maximum corrosion smart phone or tablet resistance and thermal fatigue reliability. INTEGRATED HOME .- FORM NO.G11-547 REV.1 Air Table of Contents �i R801S(DF)Series TABLE OF CONTENTS Standard&Optional Equipment ......................................................................3 Model Features/Physical Data&Specifications..................................................4 Model Number Identification............................................................................5 DimensionalData............................................................................................6 Blower Performance Data................................................................................7 Accessories....................................................................................................8 LimitedWarranty ............................................................................................9 COMFORT2 INTEGRATED HOME Air Standard&Optional Equipment a R801S(DF)Series 111111 _ •---- �,,�� HEAT EXCHANGER INTEGRATED FURNACE . " CONTROL DRAFT INDUCER R� MOTOR 1' DIRECT SPARK IGNITOR = _ WITH REMOTE SENSE — IN-SHOT BURNERS STANDARD EQUIPMENT OPTIONAL EQUIPMENT Completely assembled and wired; induced draft; pressure NOTE: Furnace is not listed for use with fuels other than switch; redundant main gas control; blower compartment door natural or L.P. (propane)gas. safety switch; solid state time on/time off blower control; limit The complete terms of limited and other warranties are control; manual shut-off valve, pressure regulator for natural available at our sales office,or through local installer. and L.P. (propane)gas;transformer; direct drive multi-speed All models can be converted by a qualified Rheem distributor blower motor. Furnaces are equipped with cooling/heating relay and transformer(40VA)ready for air conditioning or local service dealer to use L.P. (propane)gas without applications. (Please note: a thermostat is not included as changing burners. Factory approved kits must be used to standard equipment.) Flame sensor diagnostics; on-board convert from natural ie L.P. (propane)gas and may be ordered twinning;fused-protection(secondary),3rd speed option for as optional accessories from a Rheem parts distributor. continuous fan;common heat/cool terminal. For L.P. (propane)operation,refer to Conversion Kit Index Form. NOTE: For natural and L.P. (propane)gas models, direct spark ignition is 100% lockout type. WARNING THS A• • "'• :D •R USE IN NAM LE HCMEB INTEGRATED . COMFORT Air Model Features/Physical Data&Specifications a R801S(DF)Series Model Features • 80% residential Gas Furnace CSA certified • Low profile 34" cabinet ideal for space constrained installations • PlusOneT"^Diagnostics - 7 Segment LED all units . Blower shelf design-serviceable in all furnace orientations • PlusOneT" Ignition System-DSI for reliability and longevity • Integrated Controls board features dip switches for easy • Heat exchanger is removable for improved serviceability. system set up Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability. • QR code for quick access to product information from your smart phone or tablet Physical Data and Specifications U.S. and Canadian Models MODE_NUMBERS R801 SA R801 SA R801 SA R801 SA R801 SA R801 SA R801 SA R801 SA R801 S(DCANNFLCW) 050314Z'A 075317Z A 075417Z A 100317Z A 100421 Z'A 100521 Z"A 125524Z A 150524Z'A Input-BTU/H-[kW]OO 50,000[15] 75,000 [22] 75,000 [22] 100,000[29.3] 100,000[29.3] 100,000[29.3] 125,000[36.6] 150,000 [44] Heating Capacity BTU/Hr[kVV] i0 41,000[12] 60,500 [18] 60,500 [18] 80,000 [23] 80,000 [23] 81,000 [24] 99,000 [29] 120,000 [35] High Altitude Input[k\fq 45,000[13] 67,500[19.8] 67,500[19.8] 90,000[26.4] 90,000[26.4] 90,000[26.4] 112,500 [33] 135,000[39.6] High Altitude Output 36,500[10.7] 54,000[15.8] 54,000[15.8] 72,000[21.1] 72,000[21.1] 72,500[21.2] 89,000[26.1] 107,500[31.5] Capacity[kVV] Heat Ext.Static Pressure[kPa] .10[.025] .12[.029] .12[.029] .15[.037] .15[.037] .15[.037] .20[.05] .20[.05] Bower(DxVV)[mm] 11x6 11x6 11x7 11x7=10*AM 11x10 11x10 11x10 11x10 [279 x 152] [279 x 152] [279 x 178] [279 x 178] [279 x 254] [279 x 254] [279 x 254] [279 x 254] Motor HP[VA-Speeds[VA- 1/2-4-PSC 1/2-3-PSC 3/4-3-PSC 1/2-3-PSC 1/2-3-PSC 3/4-3-PSC 3/4-3-PSC 3/4-3-PSC PSC Type [373] [373] [559] [373] [373] [559] [559] [559] Motor Full Load Amps 6.8 5.8 9.5 7.1 7.9 9.5 9.5 9.5 Heating Speed LON MEDIUM LON IVIED IVIED LON LON LON Cooling Speed HIGH HIGH HIGH HIGH HIGH HIGH HIGH HIGH Cooling OAVI @.5"[kPa] ESP 1200 1200 1600 1200 2000 2000 2000 2000 (Nominal)[Us] [566] [566] [755] [566] [944] [944] 1 [944] [944] Rated ES.P.(In.WC)[kPa] 0.5[.12] 0.5[.12] 0.5[.12] 0.5[.12] 0.5[.12] 0.5[.12] 0.5[.12] 0.5[.12] Temperature Pose Range°F 25-55 30-60 25-55 45-75 40-70 40-70 40-70 50-80 [°q [13.9-30.6] [16.7-33.3] [13.9-30.6] [25-41.7] [22.2-38.9] [22.2-38.9] [22.2-38.9] [27.8-44.4] Max.Outlet Air Temp.°F 155 165 155 190 190 170 180 170 [oq [68.3] [73.9] [68.3] [87.8] [87.8] [76.7] [82.2] [76.7] Approx.Shipping Weight(Lbs.) 85 105 105 115 120 120 140 150 [kg] [38.6] [47.6] [47.6] [52.2] [54.4] [54.4] [63.5] [68.0] AFUE-Eectric Ignition Models O 80% 80% 80% 80% 80% 80% 80% 80% NOTES.Al models are 115V 601-17,10 Gas connection size for all models is 1/2"RPT O In accordance with D.QE test procedures. 02 See Oxwersion Nt Index Form for high altitude derate in US applications. [ ]Designates Metric Conversions 4 INTEGRATED • • •- Air Model Number Identification �i R801S(DF)Series Model Number Identification—Downflow Models R 80 1 S A 075 4 17 Z S A Rheem 80= 1=Single Stage S=Standard Design Series Input 3=Up to Cabinet Z=Down X=Low NOK Revision- 80%AFUE PSC A=1st Design BTU/HR[kq 3 Ton Width and Zero S=Standard Marketing 050= 50,000[15] 4=Up to 14=14" Clearance (A—First Time 075= 75,000[22] 4 Ton 17=17.5" Downflow Release) 100=100,000[29] 5=Up to 21 =21" 125=125,000[37] 5 Ton 24=24.5" 150=150,000[44] [ ]Designates Metric Conversions INTEGRATED HOME COMFORT 5 Air Dimensional Data D R801S(DF)Series Downflow Dimensions 71,e" TOP BOTTOM 111 mmI RETURN SUPPLY 193/4" 24112' AIR AIR [502 mm] [622 mm) C E 3/4' 281ho"1713 mm] A [19 mm) RL FMe' .A.B Ne"116 mm] p 2011e' we• [t6 mm) [511 mm] i[18 mmI 119 mm[ 1676 mm] 26e1e" Me"DIA.(13 mm) [676 mm] ale"DIA. LOW VOLTAGE 122 mm) ELECTRICAL 34• [ CONNECTION 1864 mm] (HIGH VOLTAGE) O 2613/,e" [594 mmI O 94 mm[ [681 mml 20�e' IIII [518 mm] 203/e" 241/,e" 1518 mm] [621 mm] GAS CONNECTION 63/1e" 63he' 1157 mm) �— [157 mm) 135 mm[ LEFT SIDE FRONT RIGHT SIDE Dimensions and Clearance to Combustible Material (inches) [mm] MODa- REDUCED CLEARANCES(IN.)[mm] R801S A B C D E (DOMFLO/� LEFT RIGHT TOP FRONT VENT SHIP.WGTS. Sff2I ES SIDE SIDE (LBS.)[kg] 050 14 [356] 1227/32[326] 103/8[264] O 131/8[333] 0 4 O 0 1 [25] 3[76] 6[152]O 85[38.6] 075 171/2[445] 1611/32[415] 121/8[308] O 165/8[422] 0 3 O 0 1 [25] 3[76] 6[152]O 105[47.6] 100317 171/2[445] 1611/32[415] 121/8[308] 10 165/8[422] 0 3 02 0 1 [25] 3[76] 6[152]® 115[52.2] 100421 21 [533] 1927/32[504] 137/8[352] D 201/8[511] 0 0 0 1 [25] 3[76] 6[152]03 120[54.4] 100521 125 241/2[622] 2311/32[593] 155/8[397] D 235/8[600] 0 0 0 1 [25] 3[76] 6[152]OO 140[63.5] 150 241/2[622] 2311/32[593] 155/8[397] D 235/8[600] 0 0 0 1 [25] 3[76] 6[152]03 150 [68] NC111S O May require a 3"[76 mm]to 4"[102 mm]or 3"[76 mm]to 5"[127 mm]adapter. O May be 0"[0 mm]with type B vent. OO May be 1"[25 mm]with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code,ANSI Z223.1 and in accordance with local codes. [ ]Designates Metric Conversions 6 INTEGRATED • • •- Air Blower Performance Data D R801S(DF)Series Blower Performance Data—Downflow Models MODEL BLONER MOTOR CFM[L/s]AIR DELIVERY R801S SIZE H.P BLONEF2 EXTERNAL STAl1C PRESSURE INCHES[kPa] WATER OCLUMN (SAES [mm] IN SPEED .1 [.02] .2[.05] .3[.07] .4[.10] .5[.12] .6[.15] .7[.17] LON 735[347] 715 [337] 690 [326] 660 [311] 635 [300] 605 [286] 575[271] 050 11 x 6 1/2 MED-1-0 1025[484] 1015 [479] 995 [470] 975 [460] 955 [451] 930 [439] 905[427] [279 x 152] [373] MED-HI 1185[559] 1165 [550] 1150 [543] 1130 [533] 1100 [519] 1075 [507] 1040[491] HIGH 1345[635] 1330 [628] 1310 [618] 1295 [611] 1265 [597] 1235 [583] 1205[569] x6 1/2 LON 1104[529] 1081 [510] 1050 [496] 1025 [484] 999 [471] 971 [458] 940[444] 075317 [279 x 52] [373] M® 1284[606] 1269 [599] 1236 [583] 1206 [569] 1179 [556] 1139 [538] 1102[520] HIGH 1478[698] 1438 [679] 1397 [659] 1362 [643] 1392 [657] 1282 [605] 1242[586] x7 1/2 LON 1210[571] 1205 [569] 1195 [564] 1180 [557] 1165 [550] 1155 [545] 1130[533] 075417 [279 x 178] [373] M® 1580[746] 1560 [736] 1550 [732] 1530 [722] 1495 [706] 1465 [691] 1430[675] HIGH 1915[904] 1880 [887] 1825 [861] 1790 [845] 1740 [821] 1675 [791] 1600[755] x7 1/2 LON 1070[505] 1055 [498] 1040 [491] 1010 [477] 980 [463] 945 [446] 905[427] 100317 [279 x 178] [3 3] MED 1240[585] 1210 [571] 1190 [562] 1165 [550] 1135 [536] 1095 [517] 1055[498] HIGH 1420[670] 1395 [658] 1370 [647] 1340 [632] 1305 [616] 1265 [597] 1220[576] LON 1303[615] 1304 [615] 1280 [604] 1250 [590] 1222 [577] 1188 [557] 1160[547] 100421 [279 x 254] [373] M® 1697[801] 1674 [790] 1655 [781] 1638 [773] 1621 [765] 1581 [746] 1542[728] HIGH 2078[981] 2068 [976] 2037 [961] 2010 [949] 1988 [938] 1938 [915] 1898[896] LON 1690[798] 1670 [788] 1655 [781] 1615 [762] 1585 [748] 1565 [739] 1525[720] 100521 [279 x 254] [559] MED — 2085 [984] 2055 [970] 2005 [946] 1970 [930] 1945 [918] 1880[887] HIGH — 2410[1137] 2355[1111] 2305[1088] 2240[1057] 2165[1022] 2100[991] LON — 1690 [798] 1660 [783] 1635 [772] 1580 [746] 1535 [724] 1480[698] 125524 [279 x 254] [559] M® — 2090 [986] 2035 [960] 1985 [937] 1930 [911] 1850 [873] 1785[842] HIGH — 2395[1130] 2335[1102] 2260[1067] 2185[1031] 2080 [982] 1965[927] LON 1675[791] 1650 [779] 1620 [765] 1570 [741] 1545 [729] 1485 [701] 1425[673] 150524 11 x 10 35 MED2105[993] 2075 [979] 2035 [960] 1990 [939] 1955 [923] 1900 [897] 1815[857] [279 x 254] [559] HIGH — — — — — — — N=R3cmr coded blower speeds are in bold. [ ]Designates Metric Conversions INTEGRATED HOME COMFORT Air Accessories �i R801S(DF)Series DOWNFLOW ACCESSORIES DOWNFLOW WARNING:Unit design is certified for installation on GXGP-F03 non-combustible floor.A special factory supplied combustible PARALLEL FURNACE KITS—are for parallel operation requirements. floor sub-base is required when installing on a combustible floor.Failure to install the sub-base may result in fire,property damage and personal injury. RXGF-CC* FILTER RACK—Ckrivr low tap return mount.Pequires(2)14 x 20 filters. COMBUSTIBLE FLOOR BASE DIMENSIONS NOTE: Filter racks are shipped Wthout filters. OOMBUSTBLE USEWITH A B C *Filters available through PROSTOCK°. FLOOR BASE FURNACESIZES IN. [mm] IN. [mm] IN. [mm] RXOGB14 801S050 141/2[368] 131/4[337] 111/4[286] RXOGB17 801S075,801SA100317 18 [457] 163/4[425] 143/4[451] RXGF-DB* RXCyGB21 801SA100421, 211/2[546] 201/4[514] 181/4[464] Each order contains(1)one box of 10 filter racks supplied without filters. 801SA100521 RX130,1324 801S125,801S150 125 [635] 233/4[603] 213/4[552] *Filters available through KNOCK"'. FOR HIGH ALTITUDES: �.--1496'rnmi HIGH ALTITUDE OPTION CODE: US— __ None required for high altitudes. T. HIGH ALTITUDE CONVERSION KITS: US.— D None required for high altitudes. 80+ HIGH ALTITUDE INSTRUCTIONS �. Caution:/Mays follow National Fuel Cas Code(NFCC)guidelines Il84 mm l when converting for high altitudes. 28"!i [121 MMI 1 —A B Hgh altitude option codes are not required for these models. H7uvever-,the burner orifice size needs to be recalculated and verified �I �: 5 mml at elevations above 2000 ft.See Installation Instructions for more FIBERGLASS 4" r 3 I.S.11.4 ky)DENSITY I102 MMI 1711 i FIBERGLASS Information. 151 mm)2" 3 LB.[1.4 k9I DENSITY FLOOR PLENUM OR 3'[78 mm1 DUCTWORK [ ]Designates Metric Conversions 7 21lie Is"mm, NOTE:FLOOR OPENING 21 lb"1546 mm]z 0 MAX PLENUM SIZE 184h"1485 mm)a C 8 INTEGRATED HOME COMFORT Air Limited Warranty D R801S(DF)Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Heat Exchanger ......................................Twenty(20)Years which fails in normal use and service within the applicable Conditional Parts(Registration Required)........Ten (10)Years period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions,contact your local contractor or the Manufacturer for a copy of the product warranty certificate. '-5 INTEGRATED HOME COMFORT Air Notes D R801S(DF)Series 10 INTEGRATED • • •- Air Notes D R801S(DF)Series '-5 INTEGRATED HOME COMFORT The new degree of comfort.' In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Heating,Cooling&Water Heating • P.O.Box 17010 Rheem Canada Ltd./Ltee • 125 Edgeware Road,Unit 1 Fort Smith,Arkansas 72917 • www.rheem.com Brampton,Ontario • L6Y OP5 INTEGRATED HOME COMFORT PRINTED IN U.S.A 7/14 QG FORM NO.G11-547 REV.1