Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20016 44th Dr Ne_BLD3744_2026
CITY OF ARLINGTON • 18204 59th Avenue NE i1�S g'ECTTONS: ,Arlington, WA 98223 360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 20016 44TH DR NE Permit#:3744 Parcel#:00898600001600 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. OWNER AP1P i .IC—ANT Valuation:.00 WEBB VICKIE Was"'"' ton Ener CONTRACTOR g gy Services 20016 44TH DR NE 3909 1 96th St S W WASHINGTON ENERGY ARLINGTON,WA 98223-4724 LY >rzwo n 3909 196th S SERVICES od,WA 98036 treet SW 2063 786648 Lynnwood, WA 98036 2063786648 MECHANICAL CONTRACTOR LIC:WASHIES851NS EXP:09/07/2021 Washington Energy Services PLUMBING CONTRACTOR 3909 196th Street SW Lynnwood,WA 98036 2063786648 LIC#: WASHIES85INS EXP: 09/07/2021 LIC#: JOB DESCRIPTION EXP: PERMIT TYPE: Residential Mechanical STORIES: CODE YEAR: 2018 DWELLING UNITS: CONST. TYPE: BUILDINGS: OCC GROUP: OCC LOAD: I-ERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a other ordinance or order of the City,of an state or federal per►nr for,or approval of,an violation of this Code or any Governor of this State.To the extent the issuance or deral law,or of any order,proc prova n Y granting of this e ,guidance advice or decision of the period of time when such construction is prohibited or restricted bl not P it is interpreted to allow construction activity during any advice or decision of the Governor of this State, this Y an state or federal law,or order,proclamation,guidance p occupancy Permit (where inhviolation of this Coand shall not be valid,The building official is authorized to prevent occu ane or use of a jurisdiction or any other ordinance or executive order of the City, de,any other City guidance advice or decision of the Governor.The building or al is autho anyrized state or federal law,or of an �'ordinances of this determined to be issued in error or on the basis of incorrect � inaccurate uorin om to suspend or revoke th s permit f itlis anon' ordinance,regulation or order,state or federal law, or an incomplete information,or in violation oft i Y order,proclamation,guidance or decision of the Governor. Y City 1 AGREE TO COMPLY WITH CITY AND STATE LAWS AUTHORIZED THEREBY;NO PERSON WILL BE REGULATING CONSTRUCTION AND IN DOING THE WORK EMPLOYED IN VIOLATION OF THE LABOR CODE O THE STAT OF WASHTNGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27, F THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HERD E ALL FEES ARE PAID. DEPUTY AND IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN UNTIL A FINAL INSPECTION HAS BEEN GRANTED. IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington mus your sales tax return form and coded City of Arlington#31 t be reported on 01. KAREN MATHEN Signature Print Name EY 3l30/21 Date 03/30/2021 cic�lsed By Date Permit#: 3744 Permit Date: 03/05/21 Project Name: Taylor Company/Applicant Name: Washingt o1r7, Company/Applicant Address: 3909 196 tl-1 :StS rgy Services City, State, Zip: Lynnwoo cj W Contact: Karen N4. hTe 98036 Phone: 206378664$ Y Email: permits cry washi Permit Type: Residentia 1 M0 n9t0nenergy com Valuation: 0.00 �hax''cal Square Feet: 0 Number of Stories: 0 Type of Construction: Occupancy Type: Scope of Work: Replacing ga,s MIC/Opportunity Zone: rnace and qC like in kind Permit Issued: Permit Expires: 09/01/202 1 DNU: Status: IN PROC I S S Assigned To: Jennifer Pittl-nan Property Parcel# Address Legal Description 00898600001600 20016 44TH DR NE 0"erName On'ner Phone WE13B VICKIE Zoning 100 SINGLE Contractors FAMILY Contractor Primary Contact Phone RESIpENCE WASHINGTON Address ENERGY SERVICES Karen Matheney 20637 S 6648 3909 196th Street Contractor Type License S W CONTRACTOR Labor& License# Fees Industries WAS!{IRS8SINS Fee Descri ption Inspection Fee Air Cond.Unit Notes 13t4<100>� Amount $75.00 $15.00 RESIDENTIAL PERMIT APPLICATION ® Department of Community& Economic Development City of Arlington • 18204 59th Ave NE•Arlington, WA 98223 • Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE, ADDITION, DECK,OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING VERIFICATION MAY BE SUBMITTED PRIOR. Project Address: 20016 44th Dr NE Plat: 00898600001600 Single-family ❑ Duplex ❑ Townhouse ❑ Addition ❑ Accessory structure 20016 44th Dr NE Proposed Area: ls' Floor: 2°d Floor: Garage: Total SF: Describe Proposal (include cross street): REPLACING GAS FURNACE AND AC LIKE IN KIND. Valuation: 8300 Owner: Vickie Taylor Address. 20016 44th Dr NE City: ARLINGTON State: WA Zip Code: 98223 Phone: 425-923-6463 Email: wevck@aol.com Applicant: WASHINGTON ENERGY SERVICES/ KAREN MATHENEY Address: 3909 196TH ST SW City: LYNNWOOD State: WA Zip Code: 98036 Phone: 206-378-6648 Email: PERMITS(&WASHINGTONENERGY.COM Contractor: WASHINGTON ENERGY SERVICES Address: 3909 196TH ST SW City: LYNNWOOD State:WA Zip Code: 98036 Phone: 206-378-6648 Email: PERMITS@WASHINGTONENERGY.COM Contact Person: KAREN MATHENEY License Number: WASHIES851NS Expiration: 9/7/21 Received 6l16LP MAR 2a�1 of 3 7,1 -1), 2J11 41 RESIDENTIAL PERMIT APPLICATION Department of Community& Economic Development L City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551 ING� Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: I-A Furnace(80+) Model# 206-378-6648 AFUE ❑ Heat Pump Model# SEER HSPE ❑ AC Unit Model# 206-378-6648 ER ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ Hydronic Piping ❑ Boiler ❑ Solid-Fuel Appliance ❑ PV System ❑ Fireplace Insert ❑ Outdoor BBQ ❑ Storage Tank ❑ Freestanding Stove ❑ Gas Piping Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Total BTU's of all Appliances: Distance from Meter to Furthest Appliance: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet Proper combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances Applicant Signature: �_ X�l Date: 3/1/21 Print Applicants Name: KAREN MATHENEY 6/16LP Page 3 of 3 PREFERRED' SERIES 13 AIR CONDITIONER WITH o REFRIGERANT i • 1 060) Product Data INDUSTRY LEADING FEATURES/BENEFITS EFFICIENCY • 13 SEER/11 EER • Microtube Technology— refrigeration system • Indoor air quality accessories available SOUND • Sound level as low as 70 dBA COMFORT tt,y� t!.t',�. v• • System supports Thermidistat- Control or standard thermostat tti 1111111� RELIABILITY 1l� • Non-ozone depleting Puron°refrigerant • Front-seating service valves :. • Scroll compressor • Intemal pressure-relief valve • Intemal thermal overload • Low-pressure switch • High-pressure switch • Filter drier • Balanced refrigeration system for maximum reliability Preferred"T�" DUR ABILITY Peron — DuraGuard Plus- protection package: Bryant's Air Conditioners with non-ozone depleting PuronO • Solid,durable sheet metal construction refrigerant provide a collection of features unmatched by any other • Steel louver coil guard family of equipment. • Baked-on,complete outer coverage, powder paint APPLICATIONS NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory ' Long-line - up 0 2fe feet .96.20 m) total equivalent (www.ahridirectory.org) for the most up-to-date ratings length, up to 20t feet . (24.3 m) condenser above information. evaporator, or up to 80 ft. (24.38 m) evaporator above condenser(See Longline Guide for more information.) • Low ambient(down to -20°F/-28.9°C)with accessory kit (3 L � \ e a m � a) § c \ / q .§ � = o > = 2 � & @ co J f \ 0- a- a) . 2 0 2 % / 2 / / / 7 k LL $ ± / C c \ E § / C 2 m 7 § ƒ § f M m 9 « _ ' o ] S E@ q / g U 7 U J k 9 U 5 2 4 q 7 0 2 w Q 7 R & 2 N a _ ■ e a Lo ® ) a a I $ k c - $ U. t k k 15 ■ a 2 2 CL I I I R k § k k K � o ■ a@ E Q 2 f m g f E : . § k # k > _ E c 011 m x Q m ■ ■ 2 0 0 0 0 . ■ ■ V u % j \� I $ ¥ ■ m m D 2 Z � . . . 1 § % E / 4 0 45 Ln 2 R ul R / \ c 7 S o co 0 0 0 0 0 0 0 ? 2 b 3 - & 2 M m R m 2 2 2 2 2 2 ■ 2 in 2 U ■ ± c c ■ o ® a: § § D ■ § ' ■ 0 0 R / 0 0 _ _ ■ Q ■ m g m p § w E p d t : : E - ; a a a a 3 3 CL r o I . . . r w D � Z � 2 � Q y y 4 w 1 $ f f T U 4 PREFERRED' I I' CONDITIONER WITII . 1 0 REFRIGERANTi 1 5 NOMINAL1 I : 1 ICI o Product Data INDUSTRY LEADING FEATURES/BENEFITS EFFICIENCY • 13 SEER/11 EER • Microtube Technology- refrigeration system • Indoor air quality accessories available SOUND • Sound level as low as 70 dBA - COMFORT • System supports Thermidistat- Control or standard I)I I I I I I I I I IN I thermostat Ip1 RELIABILITY �IIIllllllllll • Non-ozone depleting Puron@ refrigerant ll)llllllllld ' Front-seating service valves r l 11 • Scroll compressor 1111111111111 • Internal pressure-relief valve �Il1I111111IY • Internal thermal overload • Low-pressure switch • High-pressure switch • Filter drier • Balanced refrigeration system for maximum reliability Preferred` DURABILITY Peron i DuraGuard Plus- protection package: Bryant's Air Conditioners with non-ozone depleting Purone • Solid,durable sheet metal construction refrigerant provide a collection of features unmatched by any other • Steel louver coil guard family of equipment. • Baked-on,complete outer coverage, powder paint APPLICATIONS NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory • Long-line - up to 250 feet (76.20 m) total equivalent length, up to 200 feet (624.3 m) condenser above (www.ahridirectory.org) for the most up-to-date ratings evaporator, or up to 80 ft. ( 4.38 m) evaporator above information. condenser(See Longline Guide for more information.) • Low ambient(down to -20'F/-28.9'C)with accessory kit MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 14 N N N A A/N N N N N A/N A/N N A 1 2 3 A N A 0 3 6 0 0 0 a Product Tier SEER Major Voltage Variations Cooling Capacity Open Open Open Minor Family Series Series 1=AC 2= 3=13 A=Puron N=208/230-1 A=Standard O=Not 0= 0= A= Preferred SEER P=208/230-3 Defined Not Not Original (Nominal) E=460/3 Defined Defined Series Puron P",c L us Use of the AHRI Certified TM Mark indicates a manufacturer's This product has been designed and manufactured to participation in the meet Energy Star®criteria for energy efficiency when matched with appropriate coil components. However, program For verification , proper refrigerant charge and proper air flow are critical of certification for Individual to achieve rated capacity and efficiency. Installation of prOduCYS,g0 t0 ISO 9001 this pro duct should follow all manufacturing refrigerant charging and airflow instructions. Failure to confirm www.ahridirectory.org. QMI-SAI Global proper charge and air flow may reduce energy efficiency and shorten equipment life. STANDARD FEATURES Feature 18 24 30 36 42 48 60 Puron Refrigerant X X X X X X X 13 SEER/11 EER X X X X X X X Scroll Compressor X X X X X X X Louvered Coil Guard X X X X X X X Field—Installed Filter Drier X X X X X X X Front—Seating Service Valves X X X X X X X Internal Pressure—Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X Low—Pressure Switch X X X X X X X High—Pressure Switch X X X X X X X Compressor Sound Blanket X X X X X X X X=Standard 2 PHYSICAL DATA UNIT SIZE SERIES 18—E 24—E 30—E 36—E 42—C 48—C 60—D Compressor Type Scroll REFRIGERANT Puron®(R-410A) Control TXV(Puron®Hard Shutoff) Factory Charge lb (kg) 3.15 4.40 5.12 5.32 5.84 8.00 8.44 (1.43) (2.00) (2.32) (2.41) (2.65) (3.63) (3.83) Required Charge lb(kg)# 4.91 (1.20) -- -- -- COND FAN Propeller Type,Direct Drive Air Discharge Vertical Air Qty(CFM) 1792 2196 2196 3700 3170 3365 4050 Motor HP 1/12 1/10 1/10 1/4 1/5 1/4 1/4 Motor RPM 1100 1100 1100 1100 825 825 825 COND COIL Face Area(Sq.ft.) 8.40 9.85 11.49 15.09 17.25 21.56 25.15 Fins per In. 20 25 25 25 25 25 25 Rows 1 1 1 1 1 1 1 Circuits 3 5 3 4 4 5 5 VALVE CONNECT.(In.ID) Vapor 3/4 3/4 3/4 7/8 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES(In.OD) Rated Vapor* 3/4 3/4 3/4 7/8 7/8 7/8 1-1/8 Max Liquid Line 3/8 f For 15 ft.Line set -- =Factory charge and required charge values are equal *Units are rated with 25 ft(7.6 m)of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. OUTDOOR UNIT CONNECTED TO A FACTORY APPROVED INDOOR UNIT Check piston size shipped with indoor unit to see if it matches required indoor piston size. If it does not match,replace indoor piston with correct piston size in table below: OUTDOOR UNIT SIZE—SERIES FAN COIL PISTON SIZE BY OUTDOOR MODEL 018—E FB4CNF* 49 024—E FB4CNF* 55 030—E FB4CNF* 61 036—E FB4CNF* 70 042—C FB4CNF* 76 048—C FB4CNF* 78 * Ratings contained in this document are subject to change at any time.Always refer to the AHRI directory(www.ahridirectory.org)for the most up—to—date ratings information. NOTE: Pistons shipped with outdoor units are only qualified and approved with the above listed fan coils. The piston included with the FFMANP*and FPMAN* fan coils are unique to those products and CANNOT be replaced with the piston shipped with outdoor unit. Refer to the AHRI directory (www.ahridirectory.org)to check if your combination can use a piston or requires an accessory TXV. 3 REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengthst for Cooling Only Systems with Puron®Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. See Table below for liquid line sizing and maximum lengths: Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit Liquid AC with Puron Refrigerant Liquid Line Line Maximum Total Equivalent Lengtht: Outdoor unit BELOW Indoor Size Connection Diam. Vertical Separation ft(m) W/TXV 0-5 6-10 11-20 21-30 31-40 41-50 51-60 61-70 71-80 (0-1.5) (1.8-3.0) (3.4-6.1) (6.4-9.1) (9.4-12.2) (12.5-15.2) (15.5-18.3) (18.6-21.3) (21.6-24.4) 1/4 150 150 125 100 100 75 —— —— —— 18 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 225* 150 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 1/4 75 75 75 50 50 -- -- -- -- 24 3/8 5/16 250* 250* 250* 250* 250* 225* 175 125 100 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 1/4 30 -- -- -- -- -- -- 30 3/8 5/16 175 225* 200 175 125 100 75 —— —— 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 36 3/8 5/16 175 150 150 100 100 100 75 -- -- 3//8 250* 250* 250* 250* 250* 250* 250* 250* 250* 42 3/8 5/16 125 100 100 75 75 50 -- -- -- 3/8 250* 250* 250* 250* 250* 250* 250* 250* 150 48 3/8 3/8 250* 250* 250* 250* 250* 250* 230 160 —— 60 3/8 3/8 250* 250* 250* 225* 190 150 110 -- -- * Maximum actual length not to exceed 200 ft(61 m) t Total equivalent length accounts for losses due to elbows or fitting.See the Long Line Guideline for details. -- =outside acceptable range Maximum Total Equivalent Length Outdoor Unit ABOVE Indoor Unit Liquid AC with Puron Refrigerant Liquid Line Line Maximum Total Equivalent Lengtht: Outdoor unit ABOVE Indoor Size Connection Diam. Vertical Separation ft(m) w/TXV 25 26-50 51-75 76-100 101-125 126-150 151-175 176-200 (7.6) (7.9-15.2) (15.5-22.9) (23.2-30.5) (30.8-38.1) (38.4-45.7) (46.0-53.3) (53.6-61.0) 1/4 175 250* 250* 250* 250* 250* 250* 250* 18 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 1/4 100 125 175 200 225* 250* 250* 250* 24 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 1/4 30 -- -- -- -- -- -- -- 30 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 36 3/8 5/16 225* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 42 3/8 5/16 175 200 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 48 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* 60 1 3/8 1 3/8 1 250* 250* 250* 250* 250* 250* 250* 250* *Maximum actual length not to exceed 200 ft(61 m) t Total equivalent length accounts for losses due to elbows or fitting.See the Long Line Guideline for details. -- =outside acceptable range 4 REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size Puron Charge oz/ft(g/m) 3/8 0.60(17.74) (Factory charge for lineset=9 oz/266.16 g) 5/16 0.40(11.83) 1/4 0.27(7.98) Units are factory charged for 15 ft(4.6 m)of 3/8"liquid line*. The factory charge for 3/8"lineset 9 oz. When using other length or diameter liquid lines,charge adjustments are required per the chart above. Chareine Formula: [(Lineset oz/ft x total length)-(factory charge for lineset)]=charge adjustment Example 1: System has 15 ft of line set*using existing 1/4"liquid line. What charge adjustment is required? Formula: (.27 oz/ft x 15ft)-(9 oz)=(4.95)oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16"liquid line.What is the charge adjustment? Formula: (.40 oz/ft.x 45ft)-(9 oz.)=9 oz. Net result is to add 9 oz of refrigerant to the system NOTE: Conditions must be favorable for charging by subcooling method. Indoor temperature must be 70°F to 80°F(21.1°C to 26.7°C), and outdoor temperature must be 70°F to 100°F(21.1°C to 37.8°C).If outside these conditions,adjust charge for long line sets by weigh-in method. *When applicable. Refer to Physical Data Table in this PD and to the Installation Instructions for more information. LONG LINE APPLICATIONS An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter,actual length of the tubing,and vertical separation between the indoor and outdoor units. For Air Conditioner systems,the chart below shows when an application is considered Long Line. AC with Puron®Refrigerant Long Line Description ft(m)Beyond these lengths,a TXV is required Total Length Outdoor Unit Above or Below Indoor Unit TXV required beyond 50 ft.(15.2 m) TXV required beyond 20 ft.(6.1 m) AC with Puron®Refrigerant Long Line Description ft(m)(Beyond these lengths,long line accessories are required) Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 1/4+TXV No accessories needed within al- No accessories needed within 175(53.3) lowed lengths allowed lengths 5/16+TXV 120(36.6) 50(15.2)vertical or 120(36.6)total 120(36.6) 3/8 +TXV 80(24.4) 35(10.7)vertical or 80(24.4)total 80(24.4) Note: See Residential Piping and Long Line Guideline for details VAPOR LINE SIZING AND COOLING CAPACITY LOSS Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with Puron refrigerant: Vapor Line Sizing and Cooling Capacity Losses—Puron®Refrigerant 1-Stage Air Conditioner Applications Maximum Cooling Capacity Loss(%) Unit Vapor Line Total Equivalent Line Length ft.(m) Nominal Liquid Line Diameters 1-Stage AC with Puron Size(Btuh) Diameters(In.OD) (in.OD) 26-50 51-80 81-100 101-125 126-150 151-175 176-200 201-225 226-250 (7.9-15.2) (15.5-24.4) (24.7-30.5) (30.8-38.1) (38.4-45.7) (46.0-53.3) (53.6-61.0) (61.3-68.6) (68.9-76.2) 1/2 1 2 3 11,5 6 7 8 9 11 18 3/8 5/8 0 1 1 1 2 2 2 3 3 3/4 0 0 0 0 1 1 1 1 1 5/8 0 1 2 2 3 3 4 5 5 24 3/8 3/4 0 0 1 1 1 1 1 2 2 7/8 0 0 0 0 0 1 1 1 1 5/8 1 2 3 3 4 5 6 7 8 30 3/8 3/4 0 0 1 1 1 2 2 2 3 7/8 0 0 0 0 1 1 1 1 1 5/8 1 2 4 5 6 8 9 10 12 36 3/8 3/4 0 1 1 2 2 3 3 4 4 7/8 0 0 0 1 1 1 1 2 2 3/4 0 1 2 2 3 4 4 5 6 42 3/8 7/8 0 0 1 1 1 2 2 2 3 11/8 0 0 0 0 0 0 0 0 0 3/4 0 1 2 3 4 5 5 6 7 48 3/8 7/8 0 0 1 1 2 2 2 3 3 11/8 0 0 0 0 0 0 0 1 1 3/4 1 2 4 5 6 7 9 10 11 60 3/8 7/8 0 1 2 2 3 4 4 5 5 11/8 0 0 0 1 1 1 1 1 1 Applications' heiglMstrictions. See the Residential Piping and Long Line Guideline. 5 ACCESSORIES KIT NUMBER KIT NAME 18—E 24—E 30—E 36—E 42—C 48—C 60—D KAACH1401AAA CRANKCASE HEATER X X X X KAACH1201AAA CRANKCASE HEATER X X X KSACY0101AAA CYCLE PROTECTOR X X X X X X X KAAFT0101AAA FREEZE THERMOSTAT X X X X X X X KSAHS1501AAA HARD START(CAP/RELAY) X X X X X X X KSALA0301410 LOW AMBIENT KIT X X X X X X X HC40GE228 MOTOR,FAN BALL BEARING X X KSALA0601AAA MOTORMASTER 230V X X X X X X X KAALS0201LLS SOLENOID VALVE X X X X X X X KSASF0201AAA SUPPORT FEET KIT X X X KSASF0101AAA SUPPORT FEET KIT X X X X KAATD0101TDR TIME DELAY RELAY X X X X X X X KSATX0201PUR TXV PURON X X KSATX0301PUR TXV PURON X X X KSATX0401PUR TXV PURON X KSATX0501PUR TXV PURON X KSBTX0201PUR TXV PURON X X KSBTX0301PUR TXV PURON X X X KSBTX0401PUR TXV PURON X X KAAWS0101AAA WINTER START X X X X X X X x=Accessory ACCESSORY THERMOSTATS PART NUMBER DESCRIPTION T6—WEM01 Housewise—Wi—Fi®thermostat T6—PRH01—A Programmable Relative Humidity Thermostat T6—PAC01 Programmable Thermostat T6—NRH01 Non—Programmable Relative Humidity Thermostat T6—NAC01 Non—Programmable Thermostat T2—WHS01 Wi—Fi®Thermostat T2—PAC01 Programmable Thermostat T2—NAC01 Non—Programmable Thermostat T2SNAC01 Non—Programmable Standard Screen Thermostat THERMOSTAT ACCESSORIES PART NUMBER DESCRIPTION THERMOSTATS USED WITH T6—EXP EXPO Card T6—Pxx,T6—Nxx TSTATXXSEN01—B Outdoor Air Temperature Sensor T6—Pxx,T6—Nxx TSTATXXCNV10 Thermostat Conversion Kit(4 to 5 wire) —10 pack All Bryant®branded thermostats TX—MBP01 Medium Decorative Backplate T2—Nxx TX—LBP01 Large Decorative Backplate T6—Pxx,T6—Nxx,T2—Pxx 6 ACCESSORY USAGE GUIDELINE REQUIRED FOR LOW-AMBI- REQUIRED FOR LONG REQUIRED FOR ACCESSORY ENT COOLING APPLICATIONS LINE SEA COAST (Below 55°F/12.80C) APPLICATIONS* APPLICATIONS (Over 80 ft./24.38 m) (Within 2 miles/3.22 km) Ball Bearing Fan Motor Yest No No Compressor Start Assist Capacitor and Relay Yes Yes No Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Hard Shut-Off TXV Yes Yes Yes Liquid Line Solenoid Valve No No No Motor Master®Control or Yes No No Low-ambient Pressure Switch Support Feet Recommended No Recommended Winter Start Control Yes No No *For tubing line sets between 80 and 200 ft.(24.38 and 60.96 m) and/or 35 ft.(10.67 m)vertical differential,refer to Residential Split-System Longline Application Guideline. t Required for Low-Ambient Controller(full modulation feature)MotorMaster®Control. ACCESSORY DESCRIPTION AND USAGE (LISTED ALPHABETICALLY) 1.Ball-Bearing Fan Motor 6.Low-Ambient Pressure Switch Kit A fan motor with ball bearings which permits speed reduction A long life pressure switch which is mounted to outdoor unit while maintaining bearing lubrication. service valve.It is designed to cycle the outdoor fan motor in order Usage Guideline: to maintain head pressure within normal operating limits. The Required on all units when using MotorMaster@ control will maintain working head pressure at low-ambient 2.Compressor Start Assist-Capacitor and Relay temperatures down to 0°F(-17.8°C)when properly installed. Start capacitor and relay gives a"hard"boost to compressor motor Usage Guideline: at each start up. A Low-Ambient Pressure Switch must be used when cooling operation is at outdoor temperatures below Usage Guideline: 55°F(12.8°C)to a minimum of 0°F(-17.8°C). Required for single-phase scroll compressors in the Suggested for all commercial applications. following applications: 7.MotorMaster@ Low-Ambient Controller Long line A fan-speed control device activated by a temperature sensor, Low-ambient cooling designed to control condenser fan motor speed in response to the Suggested for all compressors in areas with a history of saturated, condensing temperature during operation in cooling low voltage problems. mode only.For outdoor temperatures down to-20°F(-28.9°C),it 3.Crankcase Heater maintains condensing temperature at 100°F ±10°F (37.8°C An electric resistance heater which mounts to the base of the 6.5°Q. compressor to keep the lubricant warm during off cycles.Improves Usage Guideline: compressor lubrication on restart and minimizes the chance of A MotorMaster@ Low Ambient Controller or liquid slugging. Low-Ambient Pressure Switch must be used when Usage Guideline: cooling operation is used at outdoor temperatures Required in Low-ambient cooling applications. below 55°F(12.8°C). Required in long line applications. Suggested for all commercial applications. Suggested in all commercial applications. 8.Outdoor Air Temperature Sensor 4.Cycle Protector Designed for use with Bryant Thermostats listed in this The cycle protector is designed to prevent compressor short publication. This device enables the thermostat to display the cycling.This control provides an approximate 5-minute delay after outdoor temperature.This device also power to the compressor has been interrupted for any reason, is required to enable special thermostat features such as auxiliary including power outage,protector control trip, thermostat jiggling, heat lock out. or normal cycling. Usage Guideline: 5.Evaporator Freeze Thermostat Suggested for all Bryant thermostats listed in this An SPST temperature-actuated switch that stops unit operation publication. when evaporator reaches freeze-up conditions. Usage Guideline: Required when Low-ambient kit has been added. 7 ACCESSORY DESCRIPTION AND USAGE (LISTED ALPHABETICALLY) (CONT) 9.Support Feet 11.Time-Delay Relay Four or five astick-on plastic feet that raise the unit 4 in. (101.6 An SPST delay relay which briefly continues operation of indoor mm) above the mounting pad. This allows sand, dirt, and other blower motor to provide additional cooling after the compressor debris to be flushed from the unit base,minimizing corrosion. cycles off. Usage Guideline: NOTE: Most indoor unit controls include this feature. For those Suggested in the following applications: that do not,use the guideline below. Coastal installations. Usage Guideline: Windy areas or where debris is normally circulating. Accessory required to meet AHRI rating,where indoor Rooftop installations. not equipped. For improved sound ratings. 12.Winter Start Control 10.Thermostatic Expansion Valve(TXV) This control is designed to alleviate nuisance opening of the A modulating flow-control valve which meters refrigerant liquid low-pressure switch by bypassing it for the first 3 minutes of flow rate into the evaporator in response to the superheat of the operation. refrigerant gas leaving the evaporator. Kit includes valve,adapter tubes,and external equalizer tube.Hard shutoff types are available. NOTE: When using a hard shutoff TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required. Usage Guideline: Accessory required to meet AHRI rating and system reliability,where indoor not equipped. Hard shutoff TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems. 8 AHRI RATINGS For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Bryant database at:www.MyBryantRatings.com For performance data at specific application &/or design conditions with various indoor unit combinations,the equipment performance calculator can be accessed at: http://rpmobbry.wrightsoft.com/ ELECTRICAL DATA UNIT SIZE OPER VOLTS* COMPR FAN MAX FUSE**or -VOLTAGE, V/PH MCA SERIES MAX MIN. LRA RLA FLA CKTBRKAMPS 18-E 47.5 9.0 0.5 11.8 20 24-E 62.9 10.9 0.7 14.3 25 30-E 67.8 12.8 0.6 16.6 25 36-E 208/230/1 253 197 75.0 14.7 1.4 19.8 30 42-C 112.0 17.9 1.2 23.6 40 48-C 109.0 19.9 1.2 26.2 40 60-D 134.0 26.4 1.20 34.2 50 *Permissible limits of the voltage range at which the unit will operate satisfactorily. **Time-Delay fuse. FLA -Full Load Amps LRA -Locked Rotor Amps MCA -Minimum Circuit Amps RLA -Rated Load Amps NOTE:Control circuit is 24-V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with 2007 requirements of ASHRAE Standards 90.1 A-WEIGHTED SOUND POWER (dBA) STANDARD TYPICAL OCTAVE BAND SPECTRUM(dBA,without tone adjustment) UNIT SIZE-VOLTAGE,SERIES RATING (dBA) 125 250 500 1000 2000 4000 8000 18-E 70 50.1 55.6 61.3 67.4 63.2 60.4 52.8 24-E 72 52.9 62.3 65.0 67.8 64.0 61.9 55.3 30-E 74 52.8 62.4 65.0 69.2 68.6 63.0 55.7 36-E 72 58.7 65.1 66.4 65.6 62.6 60.0 52.3 42-C 74 55.0 64.0 68.0 68.5 64.5 60.0 54.0 48-C 74 52.5 62.5 65.5 69.0 63.5 60.5 56.0 60-D 74 54.0 59.0 65.5 67.5 63.5 60.0 55.5 NOTE: Tested in accordance with AHRI Standard 270-2008(not listed in AHRI). CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE-VOLTAGE,SERIES REQUIRED SUBCOOLING°F(°C) 18-E 15(8.33) 24-E 13(7.22) 30-E 14(7.78) 36-E 10(5.56) 42-C 10(5.56) 48-C 17(9.44) 60-D 11 (6.11) 9 DIMENSIONS ING SHIPPING OPERATING SHIPP UNIT SERIES ELECTRICAL A B C D E F G 11I K WEIGHT WEIGHT LENGTH ENG(Sq WIDTH SHIPPING HEIGHT CHARACTERISTICS INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM INCH MM Lbs s Lbs K s INCH MM INCH MM 123ANA018 E Y N N N 23 1/8 587.3 25 5/16 642.9 3/4 19.1 4 7116 113.0 18 1116 459.0 7 13/16 197.9 5/16 7.9 3 76.2 11 112 292.1 13 330.2 12 1/2 317.5 117 53.1 130 59.0 25 1/4 641.5 29 3/4 755.8 123ANA024 E Y N N N 25 3/4 654.0 25 5/16 642.4 3/4 19.1 4 7116 113.0 21 114 539.9 9 1/8 231.3 5116 7.9 3 76.2 14 355.6 15 381.0 11 112 292.1 127 57.6 150 68.0 27 7/8 708.2 29 3/4 755.8 123ANA030 E Y N N N 25 3/4 654.0 28 11/16 728.7 3/4 19.1 4 7116 113.0 21 114 539.9 9 118 231.3 5/16 7.9 3 76.2 13 330.2 13 1/2 342.9 13 330.2 138 62.6 162 73.5 27 7/8 708.2 33 3/16 843.1 123ANA036 E Y N N N 31 3/16 792.5 28 11/16 728.7 718 22.2 6 9116 166.1 24 11/16 626.3 9 1/8 231.3 5/16 7.9 3 76.2 15 112 393.7 16 406.4 14 355.6 169 76.7 194 88.0 33 5/16 846.6 33 3/16 843.1 123ANA042 C Y N N N 31 3/16 792.5 32 1/16 815.1 7/8 22.2 6 9116 166.1 2411116 626.3 9 118 231.3 5/16 7.9 3 76.2 15 314 400.1 16 114 412.8 13 314 349.3 205 93.0 233 105.7 33 5116 846.6 36 5/8 929.5 123ANA048 C Y N N N 31 3116 792.5 38 7/8 987.8 7/8 22.2 6 9116 166.1 2411116 626.3 9 118 231.3 5/16 7.9 3 76.2 14 114 362.0 17 1/4 438.2 19 1/4 489.0 228 103.4 256 116.1 33 5116 846.6 43 3/8 1102.2 123ANA060 D Y N N N 35 889.0 38 7/8 987.8 7/8 22.2 6 9/16 166.1 28 7/16 722.8 9 1/8 231.3 5/16 7.9 3 76.2 20 5/8 523.9 19 3/4 501.7 18 3/8 466.7 251 113.9 285 129.3 37 1/8 943.1 43 3/8 1102.2 Y=YES NOTES: N d N=NO 1.ALLOW 24'(609.6)CLEARANCE TO SERVICE SIDE OF UNIT,48"(1219.2)ABOVE UNIT, 6"(152.4)ON ONE SIDE,12"(304.8)ON REMAINING SIDE,AND 24'(609.6)BETWEEN UNITS FOR PROPER AIRFLOW. 2.CENTER OF GRAVITY Q� . 3.SERIES DESIGNATION IS THE 14TH POSITION OF THE A S0. UNIT MODEL NUMBER. AIR DI1T1SCHARGE / \ / AIR IN AIR I F � DISCHARGE O FIELD POWER SUPPLY CONN. 15 7/8'(0 22.2) HOLE WITH AIR IN D -AIR IN X7118022.2) 1/8'(028.6) KNOCKOUT FIELD CONTROL SUPPLY CONN. ® G 0 7/8'(022.2) HOLE ®� E LIOUID3L NE�CONN. K J 3 3/4" 3 1/2" D (96.0) (88.9) I H O CVAPOR LINE CONN.I Y 50. 1 13/16' r X S0. f46.71 112' (12.71 03/8"(09.5) TIEDOWN KNOCKOUTS (2) PLACES 2 13116' AIR IN ..X.. ..Y.. (71.0) UNIT.SIZE MINIMUM GROUND MOUNTING MINIMUM ROOF-TOP MOUNTING PAD APPLICATION DIMENSIONS PAD APPLICATION DIMENSIONS 18 23 1/8 587.3 17 7/8 454.6 24.30 25 3/4 654.0 20 7/16 518.5 36,42,48 31 3/16 792.5 2215/16 583.2 NOTE:ALL DIMENSIONS IN INCH (MM) U.S. EXPORT CLASSIFICATION: EAR99 60 35 889.0 26 3/4 679.7 SD5421-4 REV.D CLEARANCES Clearances (various examples) Wall Wall 6„ 24„ (152.4 mm) Service 24" 12" 12" 6" (609.6) (304.8) (304.8) (152.4) Service 12" 12" (304.8) (304.8) Wall 24" 24" 24" (609.6) (609.6) (609.6) Service Service Service 18" 18" 18" (457.2) (457.2) (457.2) Note: Numbers in () = mm IMPORTANT: When installing multiple units in an alcove,roof well,or partially enclosed area,ensure there is adequate ventilation to prevent re-circulation of discharge air. A07833 DETAILED COOLING CAPACITIES# CONDENSER ENTERING AIR TEMPERATURES °F(°C) EVAPORATOR AIR 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) CFM EWB Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. °F(°C) Total Sens$ KW** Total Sens$ KW** Total Sens$ KW** Total Sens$ KW** Total Sens$ KW** Outdoor 12(22.2) 20.77 10.24 1.24 19.95 9.96 1.39 19.07 9.66 1.56 18.09 9.33 1.76 17.01 8.96 1.98 67(19.4) 19.01 12.71 1.25 18.21 12.41 1.40 17.37 12.09 1.57 16.44 11.75 1.77 15.41 11.39 1.99 525 63(17.2)tt 17.69 12.24 1.26 16.91 11.92 1.41 16.09 11.59 1.58 15.20 11.24 1.77 14.20 10.87 1.99 62(16.7) 17.46 15.15 1.26 16.72 14.80 1.41 15.94 14.49 1.58 15.21 15.08 1.77 14.37 14.37 1.99 57(13.9) 17.10 17.10 1.26 16.48 16.48 1.41 15.83 15.83 1.58 15.13 15.13 1.77 14.35 14.35 1.99 72(22.2) 21.08 10.74 1.27 20.25 10.46 1.42 19.34 10.15 1.59 18.33 9.82 1.79 17.21 9.44 2.01 67(19.4) 19.30 13.54 1.28 18.49 13.23 1.43 17.60 12.93 1.60 16.62 12.61 1.80 15.59 12.26 2.02 600 63(17.2)tt 17.98 13.01 1.29 17.17 12.69 1.44 16.30 12.38 1.61 15.39 12.06 1.80 14.41 11.65 2.02 62(16.7) 17.85 16.29 1.29 17.23 15.65 1.43 16.51 16.37 1.60 15.71 15.71 1.80 14.88 14.88 2.02 57(13.9) 17.75 17.75 1.29 17.10 17.10 1.44 16.42 16.42 1.61 15.68 15.68 1.80 14.86 14.86 2.02 72(22.2) 21.29 11.21 1.29 20.45 10.93 1.45 19.53 10.62 1.62 18.50 10.28 1.82 17.36 9.89 2.04 67(19.4) 19.50 14.36 1.31 18.65 14.08 1.46 17.76 13.80 1.63 16.82 13.42 1.83 15.78 13.00 2.05 675 63(17.2)tt 18.17 13.78 1.32 17.33 13.50 1.47 16.49 13.17 1.64 15.59 12.76 1.83 14.61 12.32 2.05 62(16.7) 18.39 16.74 1.31 17.64 17.64 1.46 16.93 16.93 1.63 16.16 16.16 1.83 15.30 15.30 2.05 57(13.9) 18.28 18.28 1.31 17.61 17.61 1.46 16.90 16.90 1.63 16.14 16.14 1.83 15.28 15.28 2.05 CONDENSER ENTERING AIR TEMPERATURES °F(°C) EVAPORATOR AIR 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) CFM EWB Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. °F(°C) Total Sent KW** Total Sens$ KW** Total Sens$ KW** Total Sens$ KW** Total Sens$ KW** Outdoor �. 12(22.2) 27.25 13.68 1.65 26.06 13.26 1.83 25.42 13.04 2.09 23.78 12.47 2.31 22.10 11.90 2.56 N 67(19.4) 24.87 16.90 1.65 23.80 16.48 1.84 22.68 16.05 2.05 21.79 15.71 2.37 20.31 15.15 2.59 700 63(17.2)tt 23.14 16.27 1.66 22.14 15.85 1.85 21.09 15.42 2.06 20.07 15.00 2.32 18.78 14.48 2.60 62(16.7) 22.83 20.07 1.66 21.87 19.64 1.85 20.88 19.17 2.06 20.02 19.86 2.32 18.95 18.95 2.59 57(13.9) 22.38 22.38 1.66 21.60 21.60 1.85 20.77 20.77 2.06 20.01 20.01 2.36 18.91 18.91 2.59 72(22.2) 27.61 14.35 1.68 26.41 13.93 1.87 25.79 13.72 2.13 24.06 13.14 2.34 22.56 12.63 2.62 67(19.4) 25.26 18.00 1.69 24.16 17.58 1.88 23.00 17.15 2.09 22.12 16.82 2.40 20.57 16.24 2.63 800 63(17.2)tt 23.54 17.31 1.70 22.50 16.88 1.88 21.41 16.44 2.10 20.42 16.03 2.36 19.07 15.49 2.63 62(16.7) 23.36 21.53 1.70 22.54 20.81 1.88 21.55 21.55 2.10 20.72 20.72 2.36 19.62 19.62 2.63 57(13.9) 23.27 23.27 1.70 22.42 22.42 1.88 21.55 21.55 2.10 20.76 20.76 2.41 19.59 19.59 2.63 72(22.2) 27.98 15.02 1.72 26.66 14.57 1.91 26.05 14.37 2.16 24.33 13.79 2.39 22.71 13.26 2.66 67(19.4) 25.55 19.06 1.73 24.42 18.64 1.92 23.24 18.20 2.13 22.16 17.79 2.39 20.75 17.25 2.66 900 63(17.2)tt 23.83 18.29 1.74 22.83 17.88 1.92 21.66 17.41 2.13 20.62 16.99 2.40 19.28 16.44 2.67 62(16.7) 24.00 24.00 1.73 23.11 23.11 1.92 22.19 22.19 2.13 21.34 21.34 2.40 20.14 20.14 2.67 57(13.9) 23.97 23.97 1.73 23.08 23.08 1.92 22.13 22.13 2.13 21.30 21.30 2.39 20.13 20.13 2.67 See notes on page 15 DETAILED COOLING CAPACITIES# CONTINUED CONDENSER ENTERING AIR TEMPERATURES °F(°C) EVAPORATOR AIR 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) CFM EWB Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. °F(°C) Total Sens$ KW** Total Sens$ KW** Total Sens$ KW** Total L Sens$ KW** Total Sens$ KW** Outdoor 72(22.2) 33.50 16.91 2.08 32.19 16.46 2.29 30.70 15.95 2.54 29.03 15.39 2.82 27.46 14.86 3.17 67(19.4) 30.64 21.05 2.08 29.42 20.59 2.29 28.01 20.05 2.53 26.45 19.47 2.81 24.75 18.84 3.13 875 63(17.2)tt 28.61 20.29 2.07 27.42 19.80 2.29 26.06 19.25 2.53 24.61 18.66 2.81 23.01 18.03 3.13 62(16.7) 28.25 25.13 2.07 27.13 24.61 2.29 25.89 25.89 2.53 24.71 24.71 2.81 23.39 23.39 3.13 57(13.9) 27.91 27.91 2.07 26.95 26.95 2.28 25.86 25.86 2.53 24.67 24.67 2.81 23.36 23.36 3.13 72(22.2) 33.97 17.81 2.13 32.58 17.34 2.35 31.07 16.84 2.59 29.34 16.27 2.87 27.74 15.75 3.22 67(19.4) 31.09 22.51 2.13 29.82 22.03 2.34 28.40 21.50 2.58 26.78 20.90 2.86 25.05 20.28 3.19 1000 63(17.2)tt 29.06 21.64 2.13 27.84 21.15 2.34 26.45 20.59 2.58 24.94 19.99 2.86 23.30 19.34 3.18 62(16.7) 28.99 28.99 2.12 28.00 28.00 2.34 26.84 26.83 2.58 25.57 25.57 2.86 24.17 24.17 3.18 57(13.9) 29.00 29.00 2.12 27.96 27.96 2.34 26.80 26.80 2.58 25.53 25.53 2.86 24.13 24.13 3.18 72(22.2) 34.31 18.68 2.18 32.86 18.20 2.40 31.31 17.69 2.64 29.56 17.13 2.92 27.93 16.60 3.27 67(19.4) 31.50 23.94 2.18 30.12 23.42 2.39 28.67 22.89 2.63 27.04 22.28 2.91 25.28 21.64 3.25 1125 63(17.2)tt 29.40 22.94 2.18 28.16 22.44 2.39 26.73 21.87 2.63 25.20 21.25 2.91 23.53 20.57 3.23 62(16.7) 29.90 29.90 2.18 28.79 28.79 2.39 27.60 27.60 2.63 26.26 26.26 2.91 24.79 24.79 3.24 57(13.9) 29.86 29.86 2.18 28.76 28.76 2.39 27.56 27.56 2.63 26.22 26.22 2.91 24.75 24.75 3.24 CONDENSER ENTERING AIR TEMPERATURES °F(°C) EVAPORATOR AIR 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) CFM EWB Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. °FVC) Total Sens$ KW** Total Sens$ KW** Total Sens$ KW** Total Sens$ KW** Total I Sens$ KW** 123ANA036-E Outdoor Section With CNPV*3617AL*Indoor Section 72(22.2) 45.00 21.31 2.82 42.27 20.46 2.93 39.43 1958. 3.06 36.45 18.68 3.21 33.29 17.73 3.37 67(19.4) 39.66 26.49 2.80 37.23 25.64 2.91 34.72 24.76 3.04 32.11 23.84 3.18 29.33 22.84 3.36 1050 63(17.2)tt 35.73 24.94 2.78 33.45 24.08 2.90 31.18 23.22 3.03 28.80 22.30 3.17 26.25 21.28 3.34 w 62(16.7) 36.27 36.27 2.78 34.49 34.49 2.90 32.64 32.64 3.03 30.67 30.67 3.18 28.50 28.50 3.35 57(13.9) 36.21 36.21 2.78 34.44 34.44 2.90 32.59 32.59 3.03 30.62 30.62 3.18 28.46 28.46 3.35 72(22.2) 44.13 21.83 3.08 41.23 20.95 3.20 38.29 20.06 3.32 35.19 19.14 3.47 31.92 18.16 3.64 67(19.4) 38.86 27.67 3.06 36.32 26.77 3.18 33.75 25.84 3.30 31.08 24.84 3.45 28.32 23.68 3.62 1200 63(17.2)tt 34.85 25.91 3.04 32.54 25.02 3.16 30.20 24.08 3.29 27.79 23.05 3.43 25.60 21.29 3.61 62(16.7) 36.56 36.56 3.05 34.64 34.64 3.17 32.64 32.64 3.30 30.50 30.50 3.44 28.17 28.17 3.62 57(13.9) 36.51 36.51 3.05 34.60 34.60 3.17 32.59 32.59 3.30 30.46 30.46 3.44 28.14 28.14 3.62 72(22.2) 42.95 22.22 3.34 39.98 21.33 3.46 36.93 20.42 3.58 33.75 19.48 3.73 30.38 18.48 3.90 67(19.4) 37.85 28.64 3.32 35.28 27.68 3.44 32.72 26.65 3.56 30.22 25.21 3.71 27.63 27.62 3.88 1350 63(17.2)tt 33.87 26.69 3.30 31.51 25.70 3.42 29.29 24.42 3.55 26.98 26.98 3.70 24.61 24.61 3.87 62(16.7) 36.50 36.50 3.31 34.44 34.44 3.43 32.30 32.30 3.56 30.02 30.02 3.71 27.54 27.54 3.88 57(13.9) 36.46 36.46 3.31 34.41 34.41 3.43 32.26 32.26 3.56 29.99 29.99 3.71 27.52 27.52 3.88 See notes on page 15 DETAILED COOLING CAPACITIES# CONTINUED CONDENSER ENTERING AIR TEMPERATURES °F(°C) EVAPORATOR AIR 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) CFM EWB Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. °F(°C) Total Sens$ KW** Total Sens$ KW** Total Sens$ KW** Total Sens$ KW** Total Sens$ KW** 123ANA042-C Outdoor Section With CAP-4221AL*Indoor Section 72(22.2) 48.93 25.83 3.05 46.69 24.96 3.36 44.35 24.08 3.73 41.90 23.16 4.17 39.33 22.20 4.68 67(19.4) 44.63 31.68 2.97 42.59 30.82 3.28 40.45 29.92 3.64 38.19 28.99 4.07 35.83 28.03 4.57 1225 63(17.2)tt 41.46 30.51 2.93 39.58 29.65 3.23 37.58 28.76 3.59 35.48 27.82 4.00 33.28 26.86 4.49 62(16.7) 40.87 37.50 2.92 39.07 36.62 3.22 37.20 35.70 3.58 35.25 34.67 4.00 33.36 33.36 4.50 57(13.9) 39.83 39.83 2.91 38.36 38.36 3.21 36.79 36.79 3.57 35.10 35.10 4.00 33.31 33.31 4.50 72(22.2) 49.71 26.98 3.13 47.35 26.09 3.45 44.94 25.19 3.82 42.39 24.26 4.26 39.73 23.29 4.77 67(19.4) 45.42 33.57 3.06 43.22 32.66 3.36 41.00 31.75 3.73 38.68 30.82 4.16 36.25 29.84 4.65 1400 63(17.2)tt 42.17 32.25 3.01 40.19 31.36 3.31 38.13 30.46 3.67 35.96 29.52 4.09 33.69 28.53 4.58 62(16.7) 41.78 40.06 3.00 39.96 39.11 3.31 38.09 38.09 3.67 36.34 36.34 4.10 34.43 34.43 4.60 57(13.9) 41.35 41.35 3.00 39.77 39.77 3.31 38.10 38.10 3.67 36.29 36.29 4.10 34.39 34.39 4.60 72(22.2) 50.30 28.09 3.21 47.88 27.19 3.53 45.37 26.27 3.91 42.75 25.32 4.35 40.03 24.34 4.86 67(19.4) 45.99 35.38 3.14 43.72 34.46 3.44 41.44 33.55 3.81 39.05 32.60 4.24 36.58 31.60 4.74 1575 63(17.2)tt 42.76 33.94 3.09 40.69 33.04 3.39 38.56 32.12 3.75 36.34 31.16 4.17 34.03 30.15 4.66 62(16.7) 42.58 42.58 3.08 40.97 40.97 3.40 39.19 39.17 3.76 37.30 37.30 4.19 35.30 35.30 4.70 57(13.9) 42.60 42.60 3.08 40.92 40.92 3.40 39.15 39.15 3.76 37.26 37.26 4.19 35.26 35.26 4.70 CONDENSER ENTERING AIR TEMPERATURES °F(°C) EVAPORATOR AIR 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) CFM EWB Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. °F(°C) Total Sens$ KW** Total Sens$ KW** Total Sens$ KW** Total Sens$ KW** Total I Sens$ KW** 123ANA048-C Outdoor Section With CAP**4821AL*Indoor Section 72(22.2) 54.80 28.81 3.36 52.36 27.89 3.71 49.81 26.94 4.11 47.12 25.95 4.56 44.29 24.93 5.06 67(19.4) 49.76 35.37 3.33 47.53 34.45 3.68 45.17 33.48 4.08 42.70 32.48 4.53 40.10 31.44 5.03 A 1400 63(17.2)tt 46.11 33.99 3.31 44.03 33.06 3.66 41.83 32.09 4.06 39.51 31.08 4.51 37.07 30.04 5.01 62(16.7) 45.39 41.86 3.31 43.42 40.91 3.66 41.35 39.87 4.05 39.18 39.18 4.50 37.29 37.29 5.01 57(13.9) 44.38 44.38 3.30 42.77 42.77 3.65 41.04 41.04 4.05 39.20 39.20 4.50 37.24 37.24 5.01 72(22.2) 55.95 30.53 3.46 53.38 29.59 3.81 50.68 28.61 4.21 47.88 27.60 4.66 44.93 26.56 5.16 67(19.4) 50.81 38.12 3.43 48.46 37.17 3.78 46.00 36.19 4.18 43.42 35.17 4.63 40.74 34.11 5.13 1650 63(17.2)tt 47.13 36.55 3.42 44.92 35.59 3.76 42.62 34.60 4.16 40.21 33.58 4.61 37.69 32.50 5.11 62(16.7) 46.71 45.46 3.41 44.79 44.79 3.76 42.93 42.93 4.16 40.95 40.95 4.61 38.84 38.84 5.12 57(13.9) 46.50 46.50 3.41 44.75 44.75 3.76 42.88 42.88 4.16 40.90 40.90 4.61 38.80 38.80 5.12 72(22.2) 56.45 31.49 3.52 53.81 30.54 3.87 51.07 29.55 4.27 48.20 28.54 4.72 45.19 27.47 5.22 67(19.4) 51.28 39.68 3.49 48.88 38.73 3.84 46.37 37.73 4.24 43.75 36.70 4.69 41.02 35.61 5.19 1800 63(17.2)tt 47.58 37.99 3.48 45.32 37.03 3.82 42.98 36.03 4.22 40.53 34.98 4.67 37.96 33.87 5.17 62(16.7) 47.62 47.62 3.47 45.78 45.78 3.82 43.84 43.84 4.22 41.78 41.78 4.68 39.59 39.59 5.18 57(13.9) 47.56 47.56 3.47 45.73 45.73 3.82 43.79 43.79 4.22 41.73 41.73 4.68 39.55 39.55 5.18 See notes on page 15 DETAILED COOLING CAPACITIES# CONTINUED CONDENSER ENTERING AIR TEMPERATURES °F(°C) EVAPORATOR AIR 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) CFM EWB Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. Capacity MBtuh Total Sys. °F(°C) Total Sens* KW** Total Sens* KW** Total Sens$ KW** Total Sens$ KW** Total Sens$ KW** 0.0 •Outdoor 72(22.2) 68.36 36.10 4.29 65.33 34.94 4.72 62.14 33.73 5.20 58.75 32.46 5.75 55.15 31.13 6.37 67(19.4) 62.33 44.29 4.21 59.57 43.11 4.64 56.65 41.89 5.12 53.55 40.62 5.67 50.25 39.28 6.30 1750 63(17.2)tt 57.90 42.64 4.16 55.34 41.48 4.58 52.62 40.25 5.06 49.73 38.98 5.61 46.65 37.62 6.25 62(16.7) 57.03 52.36 4.16 54.56 51.17 4.57 51.97 49.89 5.05 49.29 48.49 5.60 46.62 46.62 6.25 57(13.9) 55.44 55.44 4.13 53.46 53.46 4.56 51.33 51.33 5.05 49.04 49.04 5.60 46.55 46.55 6.24 72(22.2) 69.50 37.80 4.40 66.35 36.63 4.83 63.02 1 35.39 5.31 59.50 34.10 1 5.86 55.77 32.75 6.48 67(19.4) 63.42 47.04 4.32 60.53 45.85 4.75 57.50 44.61 5.23 54.29 43.31 5.78 50.88 41.95 6.40 2000 63(17.2)tt 58.95 45.21 4.27 56.28 44.02 4.69 53.46 42.78 5.17 50.46 41.49 5.72 47.29 40.10 6.36 62(16.7) 58.29 56.06 4.26 55.81 54.75 4.69 53.26 53.26 5.17 50.84 50.84 5.73 48.18 48.18 6.37 57(13.9) 57.63 57.63 4.26 55.50 55.50 4.68 53.22 53.22 5.17 50.77 50.77 5.72 48.13 48.13 6.37 72(22.2) 70.34 39.41 4.51 67.07 38.20 4.94 63.64 36.95 5.42 60.02 35.64 5.97 56.18 34.27 6.59 67(19.4) 64.22 49.65 4.43 61.25 48.45 4.86 58.12 47.19 5.34 54.83 45.87 5.88 51.34 44.46 6.51 2250 63(17.2)tt 59.74 47.64 4.38 56.98 46.44 4.80 54.07 45.17 5.28 51.01 43.84 5.83 47.75 42.41 6.46 62(16.7) 59.46 59.46 4.37 57.24 57.24 4.80 54.82 54.82 5.29 52.23 52.23 5.84 49.44 49.44 6.48 57(13.9) 59.43 59.43 4.37 57.17 57.17 4.80 54.76 54.76 5.29 52.15 52.15 5.85 49.39 49.39 6.48 *Tested combination. t Total and sensible capacities are net capacities.Blower motor heat has been subtracted. $Sensible capacities shown are based on 80°F(27°C)entering air at the indoor coil.For sensible capacities at other than 80°F(27°C),deduct 835 Btuh (245 kW)per 1000 CFM(480 US)of indoor coil air for each degree below 80°F(27°C),or add 835 Btuh(245 kW)per 1000 CFM(480 L/S)of indoor coil air per degree above 80°F(27°C). #Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240-2008.If additional tubing length and/or indoor unit is located above outdoor unit,a slight variation in capacity may occur. **System kw is total of indoor and outdoor unit kilowatts. "' tt At TVA rating indoor condition(75°F edb/63°F ewb).All other indoor air temperatures are at 80°F edb. EWB-Entering Wet Bulb NOTE:When the required data fall between the published data,interpolation may be performed.Extrapolation is not an acceptable practice.i. CONDENSER ONLY RATINGS* SST CONDENSER ENTERING AIR TEMPERATURES°F(°C) °F CC) 55 017D 65(18.33) 75(23.89) 85(29.44) 95(35.0) 105(40.56) 115(46.11) 30 TCG 15.90 14.80 13.70 12.80 11.90 10.90 9.90 (-1 11) SDT 69.60 78.90 88.30 97.70 107.10 116.40 125.80 KW 0.85 0.96 1.09 1.22 1.38 1.55 1.75 35 TCG 17.40 16.30 15.20 14.20 13.20 12.20 11.10 (167) SDT 70.70 80.00 89.30 98.70 108.00 117.30 126.60 KW 0.84 0.96 1.09 1.22 1.38 1.56 1.76 40 TCG 19.10 17.90 16.80 15.70 14.60 13.50 12.30 (4.44) SDT 71.80 81.10 90.40 99.70 109.00 118.30 127.50 KW 0.83 0.95 1.08 1.22 1.38 1.56 1.76 45 TCG 20.80 19.50 18.40 17.30 16.10 14.90 13.60 (7.22) SDT 72.90 82.20 91.50 100.80 110.10 119.30 128.40 KW 0.82 0.95 1.08 1.22 1.38 1.56 1.77 50 TCG 22.60 21.30 20.10 18.90 17.70 16.40 15.00 (10.0) SDT 74.10 83.40 92.60 101.90 111.10 120.30 129.40 KW 0.81 0.94 1.07 1.22 1.38 1.56 1.77 55 TCG 24.40 23.10 21.90 20.60 19.30 18.00 16.50 (12.78) SDT 75.40 84.60 93.80 103.10 112.30 121.40 130.40 KW 0.80 0.93 1.06 1.21 1.38 1.56 1.77 30 TCG 20.90 19.70 18.60 17.50 16.30 15.10 13.80 (-1 11) SDT 70.60 79.20 88.70 98.20 107.70 117.90 129.70 KW 1.13 1.26 1.41 1.59 1.80 2.05 2.39 35 TCG 23.10 21.80 20.60 19.30 18.10 16.80 15.40 (167) SDT 71.90 80.40 89.70 99.10 108.60 119.00 127.90 KW 1.13 1.26 1.41 1.59 1.80 2.06 2.32 40 TCG 25.50 24.10 22.70 21.30 19.90 18.60 17.10 (4.44) SDT 73.60 82.00 90.80 100.10 109.60 119.60 128.80 KW 1.13 1.26 1.41 1.59 1.80 2.06 2.32 45 TCG 27.90 26.30 24.90 23.40 22.00 20.60 18.90 (7.22) SDT 73.20 82.40 91.80 101.20 110.70 120.80 129.70 KW 1.11 1.25 1.41 1.59 1.80 2.06 2.32 50 TCG 30.40 28.80 27.20 25.60 24.00 22.60 20.80 (10.0) SDT 74.40 83.70 93.00 102.30 111.70 121.70 130.50 KW 1.10 1.24 1.40 1.59 1.80 2.06 2.32 55 TCG 33.10 31.30 29.60 27.90 26.20 24.70 22.40 (12.78) SDT 75.60 84.80 94.20 103.40 112.80 122.60 130.90 KW 1.09 1.23 1.40 1.58 1.80 2.06 2.30 , 30 TCG 25.50 24.20 22.80 21.50 20.00 18.50 16.90 (-1.11) SDT 71.50 80.80 89.50 98.90 108.20 117.50 126.70 KW 1.41 1.58 1.75 1.96 2.18 2.45 2.74 35 TCG 28.20 26.70 25.20 23.70 22.10 20.50 18.70 (1.67) SDT 73.60 82.10 90.70 100.00 109.30 118.50 127.70 KW 1.43 1.59 1.76 1.96 2.19 2.46 2.76 40 TCG 30.90 29.30 27.70 26.00 24.30 22.50 20.60 (4.44) SDT 73.80 83.10 92.20 101.20 110.40 119.50 128.80 KW 1.41 1.58 1.76 1.97 2.20 2.46 2.78 45 TCG 33.70 32.10 30.30 28.60 26.70 24.70 22.60 (7.22) SDT 75.10 84.50 93.40 102.50 111.60 120.70 129.90 KW 1.41 1.58 1.76 1.97 2.21 2.47 2.79 50 TCG 36.90 35.10 33.20 31.20 29.20 27.00 24.70 (10.0) SDT 76.70 85.80 94.80 103.90 112.90 121.90 131.00 KW 1.42 1.59 1.77 1.98 2.22 2.48 2.80 TCG 40.30 38.30 36.20 34.00 31.80 29.50 27.40 55 SDT 78.40 87.40 96.30 105.30 114.20 123.10 132.60 (12.78) KW 1.43 1.59 1.78 1.99 2.22 2.50 2.83 See notes on page 18 16 CONDENSER ONLY RATINGS CONTINUED SST CONDENSER ENTERING AIR TEMPERATURES°F(°C) °F(°C) 55(12.78) 65(18.33) 75(23.89) 85(29.44) 95(35.0) 105(40.56) 115(46.11) 30 TCG 32.60 30.50 28.70 27.00 25.20 23.40 21.50 (-1 11) SDT 73.10 82.60 91.10 100.30 109.70 119.00 128.30 KW 1.61 1.88 2.11 2.36 2.63 2.95 3.32 35 TCG 36.10 33.90 31.80 29.90 27.90 26.00 23.90 (167) SDT 74.30 83.90 92.40 101.60 110.80 120.00 129.20 KW 1.61 1.90 2.13 2.38 2.65 2.96 3.34 40 TCG 40.10 37.60 35.30 33.10 30.90 28.70 26.40 (4.44) SDT 76.00 85.10 93.90 102.90 112.10 121.20 130.30 KW 1.64 1.91 2.16 2.41 2.68 2.99 3.36 45 TCG 44.50 41.70 39.20 36.70 34.30 31.80 29.30 (7.22) SDT 77.80 86.60 95.60 104.40 113.40 122.40 131.40 KW 1.69 1.95 2.19 2.44 2.71 3.02 3.38 50 TCG 49.40 46.30 43.50 40.70 38.00 35.20 32.40 (10.0) SDT 79.70 88.50 97.30 106.10 114.90 123.80 132.70 KW 1.74 2.00 2.24 2.48 2.75 3.06 3.42 55 TCG 54.80 51.40 48.20 45.10 42.00 39.00 35.80 (12.78) SDT 82.20 90.70 99.20 107.90 116.60 125.30 134.00 KW 1 1.81 1 2.06 1 2.30 1 2.54 1 2.81 1 3.11 1 3.46 30 TCG 37.60 35.70 33.80 31.70 29.60 27.30 25.00 (_1.11) SDT 72.60 81.80 91.10 100.30 109.50 118.70 127.90 KW 1.92 2.15 2.40 2.69 3.02 3.40 3.84 35 TCG 41.50 39.40 37.30 35.00 32.70 30.30 27.70 (167) SDT 74.10 83.30 92.40 101.60 110.70 119.80 129.00 KW 1.94 2.17 2.43 2.72 3.05 3.44 3.89 40 TCG 45.70 43.30 40.90 38.50 36.00 33.40 30.60 (4.44) SDT 75.70 84.80 93.80 102.90 112.00 121.00 130.10 KW 1.98 2.21 2.46 2.76 3.09 3.49 3.94 45 TCG 50.10 47.50 44.90 42.20 39.40 36.60 33.70 (7.22) SDT 77.40 86.30 95.30 104.30 113.30 122.20 131.30 KW 2.03 2.25 2.51 2.81 3.15 3.55 4.01 50 TCG 54.80 51.90 49.00 46.10 43.10 40.00 36.90 (10.0) SDT 79.20 88.00 96.90 105.80 114.70 123.60 132.50 KW 2.09 2.32 2.58 2.87 3.22 3.63 4.10 55 TCG 59.70 56.50 53.30 50.10 46.90 43.60 40.20 (12.78) SDT 81.10 89.80 98.50 107.30 116.10 125.00 133.80 KW 2.17 2.39 2.66 2.96 3.32 3.73 4.21 0. 30 TCG 41.30 39.40 37.20 35.00 32.70 30.20 27.60 (-1.11) SDT 74.10 84.20 92.90 102.10 111.40 120.70 129.90 KW 2.19 2.46 2.74 3.06 3.44 3.86 4.32 35 TCG 45.50 43.40 41.10 38.60 36.10 33.50 30.70 (1.67) SDT 75.60 85.20 94.20 103.40 112.70 121.90 131.00 KW 2.22 2.48 2.76 3.10 3.48 3.90 4.37 40 TCG 50.10 47.70 45.20 42.50 39.80 37.00 34.00 (4.44) SDT 78.10 86.50 96.00 104.90 114.00 123.10 132.20 KW 2.27 2.50 2.81 3.13 3.51 3.94 4.41 45 TCG 55.10 52.40 49.60 46.70 43.80 40.70 37.60 (7.22) SDT 79.00 88.10 97.20 106.30 115.40 124.40 133.50 KW 2.28 2.53 2.83 3.17 3.55 3.98 4.45 50 TCG 60.40 57.40 54.40 51.20 48.10 44.70 41.40 (10.0) SDT 81.00 90.00 98.90 107.90 117.10 125.80 134.80 KW 2.31 2.57 2.86 3.20 3.60 4.02 4.50 TCG 66.20 62.80 59.50 56.10 52.60 49.00 45.40 55 SDT 84.00 91.90 100.70 109.70 118.40 127.30 136.10 (12.78) KW 2.37 2.60 2.90 3.24 3.63 4.06 4.54 See notes on page 18 17 CONDENSER ONLY RATINGS CONTINUED SST CONDENSER ENTERING AIR TEMPERATURES°F(°C) °F(°C) 55(12.78) 65(18.33) 75(23.89) 85(29.44) 95(35.0) 105(40.56) 115(46.11) 0.0 30 TCG 52.10 49.70 47.10 44.30 41.40 38.40 35.20 (_1 11) SDT 75.20 84.80 93.60 102.70 111.90 121.00 130.10 KW 2.70 3.04 3.39 3.79 4.25 4.78 5.40 35 TCG 57.50 54.80 51.90 48.90 45.70 42.40 39.00 (167) SDT 77.00 86.80 95.10 104.20 113.20 122.20 131.30 KW 2.74 3.11 3.44 3.84 4.30 4.83 5.45 40 TCG 63.20 60.10 57.00 53.70 50.30 46.70 43.00 (4.44) SDT 78.70 87.70 96.70 105.60 114.60 123.60 132.50 KW 2.79 3.13 3.49 3.90 4.36 4.89 5.51 45 TCG 69.30 65.90 62.40 58.80 55.10 51.30 47.30 (7.22) SDT 80.60 89.50 98.30 107.20 116.10 124.90 133.70 KW 2.85 3.19 3.56 3.97 4.43 4.96 5.57 50 TCG 75.80 72.00 68.20 64.30 60.20 56.10 51.80 (10.0) SDT 82.60 91.30 100.10 108.80 117.60 126.30 135.10 KW 2.92 3.26 3.63 4.04 4.50 5.03 5.63 TCG 82.80 78.50 74.30 70.00 65.60 61.10 56.40 55 SDT 85.70 93.40 101.90 110.50 119.20 127.80 136.40 (12.78) KW 3.04 3.34 3.71 4.12 4.58 5.11 5.71 *AHRI listing applies only to systems shown in Combination Ratings table. KW - Outdoor Unit Kilowatts Only. SDT - Saturated Temperature Leaving Compressor(°F) SST - Saturated Temperature Entering Compressor(°F/°C) TCG - Gross Cooling Capacity(1000 Btuh) 18 GUIDE SPECIFICATIONS AIR-COOLED,SPLIT-SYSTEM AIR CONDITIONER 123ANA GENERAL 1-1/2 TO 5 NOMINAL TONS System Description Fans Outdoor-mounted, air-cooled, split-system air conditioner unit — Condenser fan will be direct-drive propeller type, suitable for ground or rooftop installation. Unit consists of a discharging air upward. hermetic compressor, an air-cooled coil,propeller-type condenser — Condenser fan motors will be totally enclosed, 1-phase fan, and a control box. Unit will discharge supply air upward as type with class B insulation and permanently lubricated shown on contract drawings. Unit will be used in a refrigeration bearings.Shafts will be corrosion resistant. circuit to match up to a packaged fan coil or coil unit. — Fan blades will be statically and dynamically balanced. Quality Assurance — Condenser fan openings will be equipped with coated — Unit will be rated in accordance with the latest edition of steel wire safety guards. AHRI Standard 210. Compressor — Unit will be certified for capacity and efficiency, and — Compressor will be hermetically sealed. listed in the latest AHRI directory. — Compressor will be mounted on rubber vibration — Unit construction will comply with latest edition of isolators. ANSI/ASHRAE and with NEC. Condenser Coil — Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit — Condenser coil will be air cooled. will have c-UL-us approval. — Coil will be constructed of aluminum fins mechanically — Unit cabinet will be capable of withstanding Federal Test bonded to copper tubes which are then cleaned, Method Standard No. 141 (Method 6061) 500-hr salt dehydrated,and sealed. spray test. Refrieeration Components — Air-cooled condenser coils will be leak tested at 150 — Refrigeration circuit components will include liquid-line psig and pressure tested at 450 psig. shutoff valve with sweat connections,vapor-line shutoff — Unit constructed in IS09001 approved facility. valve with sweat connections, system charge of Puron@ Delivery,Storage,and Handling (R-410A)refrigerant,and compressor oil. — Unit will be shipped as single package only and is stored Unit will be equipped with filter drier for Puron refrigerant. and handled per unit manufacturer's recommendations. Warranty(for inclusion by specifying engineer) Operating Characteristics — U.S.and Canada only. — The capacity of the unit will meet or exceed Btuh at a suction temperature of °F/°C. The power PRODUCTS consumption at full load will not exceed kW. Equipment — Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of Btuh Factory assembled, single piece, air-cooled air conditioner unit. conditions of CFM entering air temperature or greater at Contained within the unit enclosure is all factory wiring, piping, at the evaporator at °F/°C wet bulb controls, compressor, refrigerant charge Puron@ (R-410A), and and °F/th dry bulb, and air entering the unit at special features required prior to field start-up. °F/°C. Unit Cabinet — The system will have a SEER of Btuh/watt or — Unit cabinet will be constructed of galvanized steel, greater at DOE conditions. bonderized,and coated with a powder coat paint. Electrical Requirements — Nominal unit electrical characteristics will be v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of v to V. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. 19 ©2019 Bryant Heating&Cooling Systems 7310 W.Morris St. Indianapolis,IN 46231 Edition Date:10/19 Catalog No.PDS123A-12 Manufacturer reserves the right to discontinue,or change at any time,specifications or designs without notice and without incurring obligations. Replaces:PDS123A-11 20 y °� RESIDENTIAL PERMIT APPLICATION Department of Community& Economic Development ��lING�O City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE, ADDITION, DECK, OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING VERIFICATION MAY BE SUBMITTED PRIOR. Project Address: 20016 44th Dr NE Plat: 00898600001600 Single-family ❑ Duplex ❑ Townhouse ❑ Addition ❑ Accessory structure 20016 44th Dr NE Proposed Area: 1 st Floor: 2nd Floor: Garage: Total SF: Describe Proposal (include cross street): REPLACING GAS FURNACE AND AC LIKE IN KIND. Valuation: 8300 Owner: Vickie Taylor Address: 20016 44th Dr NE City: ARLINGTON State: WA Zip Code: 98223 Phone: 425-923-6463 Entail: wevck@aol.com Applicant: WASHINGTON ENERGY SERVICES/ KAREN MATHENEY Address: 3909 196TH ST SW City: LYNNWOOD State: WA Zip Code: 98036 Phone: 206-378-6648 Entail: PERMITS(@-WASHINGTONENERGY.COM Contractor: WASHINGTON ENERGY SERVICES Address: 3909 196TH ST SW City: LYNNWOOD State:WA Zip Code: 98036 Phone: 206-378-6648 Entail: PERMITS@WASHINGTONENERGY.COM Contact Person: KAREN MATHENEY License Number: WASHIES851NS Expiration: 9/7/21 6/16LP Page 1 of 3 G1�Y °� RESIDENTIAL PERMIT APPLICATION Department of Community& Economic Development ��lING�O City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 Plumbing Section (continue filling out if plumbing is involved) (Check all that apply and indicate the number of fixtures proposed) ❑ Bath/Shower Combo (4.0) x Q Sink (1.5) x ❑ Shower (2.0) x ❑ Lavatory (1.0) x ❑ Clothes Washer (4.0) x ❑ Water Closet (2.5) x ❑ Dishwasher (1.5) x ❑ Water Heater x ❑ Hose Bibb (2.5) x Water Heater Model # ❑ Other (list) x Plumbing Section Continued Proposed Water Piping Size: Proposed DWV Material: Proposed Piping Material: Proposed DWV Size: • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) 6/16LP Page 2 of 3 G1�Y °� RESIDENTIAL PERMIT APPLICATION Department of Community& Economic Development ��lING�O City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: DI Furnace (80+) Model # 206-378-6648 AFUE Q Heat Pump Model # SEER HSPE ❑ AC Unit Model # 206-378-6648 SEER ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ Hydronic Piping ❑ Boiler ❑ Solid-Fuel Appliance ❑ PV System ❑ Fireplace Insert D Outdoor BBQ ❑ Storage Tank ❑ Freestanding Stove ❑ Gas Piping ❑ Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Total BTU's of all Appliances: Distance from Meter to Furthest Appliance: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances Applicant Signature: �_ Xfl Date: 3/1/21 Print Applicants Name: KAREN MATHENEY 6/16LP Page 3 of 3 Specifications -Length 29 -Width 14.2 -Height 33.33 -Weight 119 -Equipment Type Gas Furnace -Air Flow 4-way Multipoise -Fuel Type Convertible to Propane,Natural Gas -Blower Motor Type Fixed-Speeds. Constant Torque ECM -Blower Motor HP 1/3 -Blower Motor Speeds Multi-Speed ECM -Blower Motor RPM 1050 -Blower Wheel Gx10 -Drive Type Direct Drive -Maximum Pressure 13.G -Gas Connection Size 1/2 -Heat Exchanger Type Aluminized Steel Clamshell -Number Of Burners 2 -Ignition Type Silicon Nitride Hot Surface -Configuration U pflow:Downflow;Horizonta I -Includes Filter Pack No -Color Taupe Metallic -Cycle GO -Phase Single -Voltage 115 -Maximum Fuse Size 15 -Pnase Singie -Voltage 115 -Maximum Fuse Size 15 -Minumum Circuit Breaker 15 -IFM Full Load 4.4 -BTU Input 44000 -BTU Output 36000 -AFUE 80 -CFM Cooling 1080 -CFM Heating 710 -Tonnage 3 -Energy Star Rated No -LEED Certified No -ETL Certified No -ETL Listed No -UL Listed No -UL Recognized No -Package Quantity 1 -Shipping Length 16 -Shipping Width 31 -Shipping Height 36 -Shipping Weight 104 -UPC/Optical Product Code 1P800SA3604SE14 -Country Of Origin United States of America -Country Of Origin - ISO Code US -Shipping Point 46231 CITY OF ARLINGTON Dw 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT Permit#:3744 20016 44TH DR NE PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Parcel#: 00898600001600 Valuation: .00 OWNER APPLICANT CONTRACTOR WEBB VICKIE Washington Energy Services WASHINGTON ENERGY SERVICES 20016 44TH DR NE 3909 196th St SW 3909 196th Street SW ARLINGTON,WA 98223-4724 Lynnwood,WA 98036 Lynnwood,WA 98036 2063786648 2063786648 LIC:WASHIES851NS EXP:09/07/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Washington Energy Services 3909 196th Street SW Lynnwood,WA 98036 2063786648 LIC#:WASHIES85INS EXP: 09/07/2021 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. r P41- KAREN MATHENEY 3/30/21 03/30/2021 Signature Print Name Date Meleased By Date CONDITIONS 3"concrete pad with seismic bracing attached.Provide electrical disconnect.Lines shall be insulated;use of adhesive tapes are prohibited.Adhere to approved appliances.Approved job copy shall be onsite for inspections.Call for final inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 03/30/2021 Inspection Fee $75.00 03/30/2021 Air Cond. Unit $15.00 03/30/2021 Forced Air Heat $15.00 03/30/2021 Mechanical Base $25.00 03/30/2021 Processing/Technology Fee $25.00 03/30/2021 Credit Card Surcharge $4.65 Total Due: $159.65 Total Payment: $159.65 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON Dw 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT Permit#:3744 20016 44TH DR NE PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Parcel#: 00898600001600 Valuation: .00 OWNER APPLICANT CONTRACTOR WEBB VICKIE Washington Energy Services WASHINGTON ENERGY SERVICES 20016 44TH DR NE 3909 196th St SW 3909 196th Street SW ARLINGTON,WA 98223-4724 Lynnwood,WA 98036 Lynnwood,WA 98036 2063786648 2063786648 LIC:WASHIES851NS EXP:09/07/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Washington Energy Services 3909 196th Street SW Lynnwood,WA 98036 2063786648 LIC#:WASHIES85INS EXP: 09/07/2021 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 03/30/2021 Signature Print Name Date Meleased By Date CONDITIONS 3"concrete pad with seismic bracing attached.Provide electrical disconnect.Lines shall be insulated;use of adhesive tapes are prohibited.Adhere to approved appliances.Approved job copy shall be onsite for inspections.Call for final inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 03/30/2021 Inspection Fee $75.00 03/30/2021 Air Cond. Unit $15.00 03/30/2021 Forced Air Heat $15.00 03/30/2021 Mechanical Base $25.00 03/30/2021 Processing/Technology Fee $25.00 03/30/2021 Credit Card Surcharge $4.65 Total Due: $159.65 Total Payment: $159.65 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 3744 Permit Date: 03/05/21 Permit Type: RESIDENTIAL MECHANICAL Project Name: Taylor Applicant Name: Washington Energy Services Applicant Address: 3909 196th St SW Applicant, City, State, Zip: Lynnwood, WA 98036 Contact: Karen Matheney Phone: 2063786648 Email: permits@washingtonenergy.com Scope of Work: Replacing gas furnace and AC like in kind Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 03/30/2021 Permit Expires: 09/01/2021 Form Permit Type: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 100 SINGLE 00898600001600 20016 44TH DR NE WEBB VICKIE FAMILY RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# WASHINGTON Karen Matheney 2063786648 3909 196th Street CONSTRUCTION COA 603 522 032 ENERGY SERVICES SW CONTRACTOR WASHINGTON Karen Matheney 2063786648 3909 196th Street CONSTRUCTION Labor&WASHIES85INS ENERGY SERVICES SW CONTRACTOR Industries Fees Fee Description Notes Amount Inspection $75.00 Air Cond.Unit Btu/h< 100>; $15.00 Btu/hp>500 Forced Air Heat fee per Btu $15.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Credit Card Service $4.65 Total $159.65 Attached Letters Date Letter Description 03/30/2021 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 03/30/2021 CRAIG OLSON 85732040 $155.00 03/30/2021 Craig Olson 85732040 Jennifer Pittman $4.65 Outstanding Balance $0.00 Uploaded Files Date File Name 03/30/2021 8437596-3744 Issued Permit.pdf 03/05/2021 8280466-3744 Application.pdf 03/05/2021 8280467-3744 Furnace Specs.pdf 03/05/2021 8280468-3744 AC Specs.pdf