Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20501 OLYMPIC PL NE, SUITE 102_BLD5726_2026
COMMERCIAL TENANT IMPROVEMENT 40 PERMIT APPLICATION Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 The following information is required for Commercial, Multi-Family,and Mixed-Use Building Permit Applications. Mark each box to designate that the information has been provided.Please submit this checklist as part of the submittal documents. See ASSISTANCE BULLETIN #30 for detailed design requirements. EACH BUILDING OR STRUCTURE REQUIRES A SEPARATE SUBMITTAL. SUBMIT ELECTRONIC FILES FOR EACH OF THE FOLLOWING;Incomplete applications will not be accepted. REQUIRED DHCUMENTs F71 City of Arlington Commercial Tenant Improvement Permit Application ❑ Site Plan 0 Architectural Plans ❑ Structural Plans ❑ Structural Calculations 0 Mechanical System Modifications,(if applicable) 0 Plumbing System Modifications,(if applicable) ❑ Project Specification Manuals,(if applicable) ❑ WSEC Compliance Forms,(if applicable) htWs:.I/waenergycodes.com/ ❑ Special Inspection and Testing Agreement ❑✓ Deferred Submittal Request ❑ Airport Property Lease (if building is located within the Arlington Airport Property Boundary) 1. Plan Review fee is due at time of submittal and remaining balance will be due at time of issuance. 2. The City of Arlington does not review or inspect electrical systems.Contact Labor and Industries at Ini.wa.gov or 360-416-3000. A. DEFERRED SUBMITTALS If the project requires any of the following,a Deferred Submittal Request MUST be completed.Deferred submittals require separate applications,plans and plan review. 1. Mechanical Plans(if not included in the plan set) 2. Plumbing Plans (if not included in the plan set) 3. Fire Sprinkler 4. Fire Alarm S. Signage B. SPECIAL INSPECTION AND TESTING AGREEMENT A Special Inspection Firm is required to perform special inspections for the following type of work. *The Special Inspection and Testing Agreement MUST be submitted with the Building Application. ❑ Reinforced Concrete ❑ Structural Steel and Welding ❑ Bolting in Concrete ❑ High-Strength Bolting ❑ Pre-stressed Concrete ❑ Spray-Applied Fireproofing ❑ Shotcrete ❑ Smoke-Control Systems ❑ Structural Masonry ❑ Other-Specify: F--,] I acknowledge that all items designated as submittal requirements must accompany my Tenant Improvement Permit Application to be considered a complete submittal, COMMERCIAL TENANT IMPROVEMENT INSTALLATION,MODIFICATION OR REMOVAL MAY REQUIRE A SEPARATE PERMIT SUBMITAL *CHECKALL THATAPPLY El Automatic fire extinguishing systems ❑ Compressed gas systems ❑ Fire pumps ❑ Flammable and combustible liquids(tanks,piping etc.) ❑ Standpipe systems ❑ Hazardous materials ❑ Private fire hydrants ❑ Industrial ovens/furnace 21 Fire alarm and detection systems ❑ Spraying or dipping operations ❑ High piled/rack storage ❑ Temporary membrane structure,tents(>200 sq.ft.)or canopies(>400 sq.ft.) ❑ Provide details on any of the above checked items: Type of Permit: ❑✓ New Space ❑ Addition ❑ Alteration Property Address: 20501 Olympic PI Suite 104 Arlington,WA 98223 Project Valuation: 150000 Lot#: 13 Parcel ID No.: 00847300001300 Subdivision: Project Scope of work: Tenant Improvement for a Coffee shop IBC Construction Type: VA IBC Occupancy Type: S-1 Building/Space Square Footage: 2,037 Number of Stories: Square Footage Per Floor: 1st 2,037 2nd 3rd 4th 5th 6th Primary Contact: ❑ Owner ❑ Architect ❑ Engineer ✓❑ Contractor Owner Name: Scott Wammack Office No.: 360-435-7171 Email Address: gv@grandviewinc.net Cell No.: 425-359-5630 Mailing Address: PO Box 159 City:Arlington State: WA Zip:98223 Architect Name: Glenn Wells Office No.: Email Address: glennwelisarchitect@gmaii.com Cell No.: 360-239-5971 Mailing Address: 3423 29th Ave NE City: Olympia State: WA _ Zip: 98223 Professional License Number: 40324 Expiration Date: 03/31/2024 Engineer Name: Robison Engineering Office No.: 206-364-3343 Email Address: jrobison@robisonengineering.com Cell No.: Mailing Address: 19401 40th Ave W City: Lynnwood State: WA Zip:98036 Professional License Number: Expiration Date: Primary Contractor: Grandview North LLC Office No.: 360-435-7171 Email Address: gv@grandviewinc.net Cell No.: 425-359-5630 Mailing Address: PO BOX 159 City: Arlington State:WA zip: 98223 L&I Contractor License Number: GRANDLO13KP Expiration Date: 07/14/2024 REV03.2022 Page 2 of 6 COMMERCIAL TENANT IMPROVEMENT MECHANICAL SYSTEM INFORMATION Type of Permit: El New Installation ❑ Addition ❑ Alteration ❑ Replaced ❑ Gas Piping Mechanical Contractor: A&D Mechanical Office No.: 425-923-5923 Email Address: IOadmechanical q@gmaii.com Cell No.: Mailing Address: 9726 Waterworks Rd city: Marysville State: WA Zip: 98271 L&I Contractor License Number: DMECHDM902CD Expiration Date: 04/25/2024 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured per IFGS,Section 415 • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of each appliance Gas Piping Specification and complete Schematic PAGE 4 ❑ Not Applicable Proposed Piping Material: ❑CSST ❑ Brass ❑ Black Steel El Galvanized Steel ❑ Other Proposed Piping Size: ❑ 1/2" ❑ 5/s" ❑ 3/4" ❑ 1" 0 11/2" ❑ 2" Inlet Pressure: 2 PSI Pressure Drop: Specific Gravity: . MECHANICAL PERMIT FEES (per unit) Type of Fixture No.of Units Cost per Unit Subtotal Additional Plan Review fees _ x $ 75.00 = $ Air Cond.Unit<_100Btu h x $ 15.00 = $ Air Cond.Unit>100Btu h 1 x $ 25.00 = $25.00 Air Cond.Unit>50OBtu/hp x $ 50.00 = $ Air Handling Units 1 1 x $ 15.00 = $25.00 Base Mechanical Fee $ 25.00 $ 25.00 Boiler<100Btu h>3h x $ 15.00 = $ Boiler>1 million Btu/h<50hp x $ 25.00 = $ Boiler>1.5 million Btu/h<50hp x $ 50.00 = $ Boiler>100Btu h 3-15h x $ 15.00 = $ Boiler>500Btu h 15-30hp x $ 25.00 = $ Commercial Hoods -Type I x $ 25.00 = $ Commercial Hoods -Type II x $ 50.00 = $ Diffusers 10 x $ 15.00 = $150.00 D er Ducting x $ 15.00 = $ Ductwork(drawings required) 1 x $ 25.00 = $25.00 Evaporative Coolers x $ 15.00 = $ Exhaust/Ventilation Fans 1 x $ 15.00 = $15.00 Fire lace Insert/Stove x $ 15.00 = $ Forced Air Heat<_100 Btu h x $ 15.00 = $ Forced Air Heat>100 Btu/h x $ 25.00 = $ Gas Clothes Dr ,er x $ 15.00 = $ Gas Fired AC <_100 Btul x $ 15.00 = $ Gas Fired AC>100 Btu h x $ 25.00 = $ AEV03.2022 Page 3 of 6 COMMERCIAL TENANT IMPROVEMENT MECHANICAL PERMIT FEES (per unit) Gas Fired AC> 500 Btu h x $ 50.00 = $ Gas Pi in <_ 5 units 1 x $ 15.00 = $15.00 Gas Piping> 5 units (plus <5 units) x $ 2.00 = $ Heat Exchangers x $ 15.00 = $ Heat Pump-Condensing Unit x $ 25.00 _ $ Hot Water Heat Coils x $ 15.00 = $ Miscellaneous Appliance-regulated by x $ 15.00 = $ mechanical code,not otherwise specified Pkg.Units<_100btu x $ 25.00 = $ Pk . Units>100btu x $ 50.00 = $ Ran Cook top-Gas Fired x $ 15.00 = $ Refrigeration Unit<-100Btu/h 2 x $ 15.00 = $30.00 Refrigeration Unit>100Btu h x $ 25.00 = $ Refrigeration Unit>500Btu/h x $ 50.00 = $ Re-inspection fee (all) x $ 75.00 = $ Unit Heaters :5 100 Btu h x $ 15.00 = $ Unit Heaters>100 Btu h x $ 25.00 = $ VAV Boxes (Variable Air Volume,part of air x $ 10.00 = $ conditioning system) Wall Heaters-Gas Fired x $ 25.00 = $ Water Heater-Gas Fired 1 x $ 25.00 = $25.00 Permit Fee $335.00 Table 4-8; Plan Review Fee $ Processing/Technology Fee $25.00 Total $360.00 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY—USE A SEPARATE SHEET, IF NECESSARY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE:Any interior pressure regulators must be indicated REV03.2022 Page 4 of 6 COMMERCIAL TENANT IMPROVEMENT PLUMBING SYSTEM INFORMATION Type of Permit: O New Installation O Addition O Alteration O Replaced O Industrial Plumbing Contractor: Absolute Plumbing Office No.: Email Address: pawl@absoluteplumbingwa.com Cell No.: Mailing Address: PO BOX 1455 City: Mount Vernon State: WA Zip: 98273 L&I Contractor License Number: ABSOLP*799MB Expiration Date: 07/12/2024 The following items need to be specified on the plans: O Fixture specifications and equipment with locations. 0 Location and type of all backflow assemblies for each fixture. O Calculations for Grease Interceptor. O Pipe size and location of sanitary and potable water systems. O Riser diagram of waste,vent, and rain water systems,including sizes. 0 Medical gas piping riser diagram,type of gas,storage room and size of piping. PLUMBING PERMIT FEES (per fixture) Commercial plumbing permits are required to submit line drawings.A plan review fee of 65%per Table 4-6 for plumbing permits will be assessed at time of submittal.Includes two f 21 ins ections with permit. Type of Fixture No.of Fixtures Cost per Fixture Subtotal Additional Plan Review fees x $ 75.00 = Alteration/repair piping x $ 15.00 = Backflow Assembly x $25.00 = Base Plumbing Fee $ 25.00 $25.00 Bath Shower Combo x $ 15.00 = Building Main Waste 1 x $ 25.00 = 25.00 Clothes Washer x $ 15.00 = Dishwasher 1 x $ 15.00 = 15.00 Drinking Fountain x 1 $ 15.00 = Floor Drains 2 x $ 15.00 = 30.00 Grease Interceptor 1 x $ 75.00 = 75.00 Grease Trap 1 x $ 25.00 = 25.00 Hose Bibb x $ 15.00 = Icemaker Refri erator 2 x $ 15.00 = 30.00 Irrigation-per meter x $ 25.00 = Kitchen Sink&Disposal 2 x $ 15.00 = 30.00 Laundry Tray x $ 15.00 = Lavatory x $ 15.00 = Med Gas Pipings 5 inlets outlets 1 x $ 60.00 160.00 Med Gas Piping> 5 inlets/outlets (plus<_ 5 x $ 5.00 = inlets outlets Miscellaneous-regulated by plumbing x $ 15.00 = code,not otherwise specified Pretreatment Interceptor x $ 15.00 = REV03.2022 Page 5 of 6 COMMERCIAL TENANT IMPROVEMENT PLUMBING PERMIT FEES (per fixture) Re-inspection Fee (all) x $ 75.00 = Roof Drains 2 x $ 15.00 = 15.00 Shower(only) x $ 15.00 = Sink bar,service, etc. 3 x $ 15.00 = 45.00 Toilets 2 x $ 15.00 = 30.00 Urinal x $ 15.00 = Vacuum Breakers x $ 25.00 = Water Heater x $ 25.00 = Water Heater-Tankless 1 x $ 25.00 = 50.00 Permit Fee 455.00 Table 4-6; Plan Review Fee Processing/Technology Fee $25.00 Total 480.00 PROPOSED BUILDING USE ❑ New ❑ Addition/Alteration ❑ Medical ❑ Automotive Based ❑ Industrial ❑ Office ❑ Restaurant ❑ Machine Shop 0 Other: Coffee Shop CROSS CONNECTION Please check all appliances that are proposed or permanently connected to the water supply. El Ice Machine ❑ Dialysis Equip. ❑ Air washers ❑ Coffee Urn/Espresso ❑ Hydrotherapy Equip. ❑ Steam Generators ❑ Carbonated Bev. ❑ Dental Equip. ❑ Dye Vats ❑ Fume Hoods ❑ Laboratory Equip. ❑ Pressure Washers ❑ Degreasers ❑ Autoclave/Sterilizers ❑ Cooling Towers ® Hot Tub/Spa ❑ Decorative Fountain ❑ Fire Sprinkler ❑ Aquarium ❑ Swimming Pools ❑ Sprinkler w/chemicals ❑ Lawn Irrigation ❑ Well on property ❑ Other: WASTEWATER DISCHARGE Does the plumbing system currently have a grease interceptor? 0 Yes ❑ No ❑ Don't Know Does the plumbing system currently have an oil/water 0 Yes ❑ No ❑ Don't Know separator? Is water used in the business process (washing, rinsing,? ❑ Yes 0 No ❑ Don't Know cooling)? Does your business require a NPDES permit? ❑ Yes 0 No ❑ Don't Know 1 hereby certify that 1 am the❑owner, ❑Applicant, ❑Contractor,and authorized to sign this application and that the above information is correct and construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulation of the State of Washington,and the City ofArlington.A final inspection and approval shall be obtained when complete. /� Scott Wammack 11/30/2023 Signature Print Name Date SAVE PRINT REV03.2022 Page 6 of 6 DEFERRED SUBMITTAL REQUEST Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 •Phone (360) 403-3551 The undersigned has been issued a permit for construction prior to final approval of the following. The following items shall be considered deferred submittals and shall be submitted AND approved prior to installation. Property Address: 20501 Olympic Place Unit 104 Parcel ID No.: 13 Project Name: The Lux a R Project Description: Tenant Improvement for cofFe-pshop Primary Contact: ✓❑ Owner ❑ Owner's Agent Owner Name: Scott Wammack Office No.: 360-435-7171 Email Address: gv@grandviewinc.net Cell No.: 425-359-5630 Mailing Address: PO Box 159 Cit,,: Arlington State: WA Zip:98223 Owner's Agent: Office No.: Email Address: Cell No.: Mailing Address: City: State: Zi;): LIST ALL ITEMS PROPOSED TO BE DEFERRED ESTIMATED DATE OF SUBMITTAL ITEM: Automatic fire extinguishing systems DATE: 12/11/2023 ITEM: Fire alarm and detection systems DATE: 12/11/2023 ITEM: Fire sprinkler DATE: 12/11/2023 ITEM: DATE: ITEM: DATE: ITEM: DATE: I, [E]Owner/❑ Owner's Agent,hereby assumes all risk,financially and otherwise,for any construction performed that may need to be removed if the deferred submittals listed above are not appropriate. 1 understand that certain inspections will NOT be performed until the submissions are accepted,reviewed and issued.I understand additional fees will be required based on the additional time spent for plan review.All deferred submittals must be submitted to the City of Arlington Community and Economic Development Department for review. Scott Wammack 11/27/2023 Signature Print Name Date SAVE PRINT REV03.2022 54"MIN. PLAM.WAINSCOT TYP. 54"MIN. P1AM.WAINSCOT TYP. AROUND PERIMETER OF AROUND PERIMETER OF 12" 42"MIN. RESTROOM(ALL WALLS) 42"MIN. 12" RESTROOM(ALL WALLS) - -. q MIN.4'ABOVE FLOOR. q MIN.4'ABOVE FLOOR , SOAP DISPENSER SOAP DISPENSER E E Highland Dr z+nx St HE _ - r--� - _ DEMO EXISTING CLOSET P.T.DISPENSER 24"x36"S.S.MIRROR `�'•"`•'� a 39"-41" 24"x36"S.S.MIRROR 36^MIN. 3g'-41" 36'MIN. N P.T.DISPENSER w w.A' 2'-0" 12" 12" 2'-0" z b.LEVER HANDLE MIN MI _ z MIN MIN Fa.LEVER HANDLE w-angi5 B cr,.w .reoa°cr.°w AREA OF WORK To - FAUCET - z FAUCET T x x aX orroe. ,y a° S vo00s[NE s c 6 24"MIN. WRAP PIPES IN FLOOR TO r 24"MIN. r SHEET VINYL WRAP PIPES IN z ' 42"MAX. RIGID INSUL.i0 EXTEND UPWARDS Ib"MIN. 42"MAX I. w/6"COVED BASE RIGID INSUL.TO a, you PREVENT BURNS ON WALL 6" —,,.INPREVENT BURNS IS"MAX. IS"MAX. W SIT EA A B A B d E o ORESTROOM ELEVATIONS RESTROOM ELEVATIONS 10,st St NE SCALE: 1/4"=1._0„ O SCALE: 1/4 s� N STRICTURE ABOVE VICINITY MAP L-------- J SCALE: N.T.S. I,,< (1) N KEY PLAN 6"ROCK WOOL CODE INFORMATION SCALE: N.T.S. f2x4 RACE a S'-0"O.C. AT DOORS BUILDING AREA: 37,978 S.F. TOTAL BUILDING HEIGHT: 53'-2" CODE: 2018 IBC LEGEND TYPE OF CONSTRUCTION: VA OCCUPANCY: B AS.5USP, SPRINKLER SYSTEM: YES NFPA 13 EXISTING WALL CEILING FIRE ALARM: YES 2"GRID T.I. AREA: 2,037 S.F. NEW WALL ANGLE OCCUPANT LOAD: 39 PERSONS ca. CATCH BASIN STUDS a I6"O.C.R-II ROCK WOOL FILL-IN TO 5/5"GW5 EACH SIDE ALIGN w/WALL MATCH EXISTING 2x4 P.T.BOTTOM PLATE SECURED i0 CONCRETE w/0.145"DIA.PINS a 24"O.C. 0 II caeE a ORDER F--- ccwmffxlsi rtuwx w G UJIF DINING ROOM 36"MIN.WIDE BYiExR - LI (35)SEATS 36"MAX.HIGH DELIR MAX OCC.=49 ACCESSIBLE COUNTER I OINTERIOR WALL c8. m SCALE: 1'=1'-0' oil � I e ���� V a�1Dt' a�1DP a� F OOR �� a rnEx I � •Di •Di 10� uoE D IN �-J i'� Z —R 0 ' _ KITCHEN x - 1 5 4 DOOR SCHEDULE m �00°"5 PREP/ a DOOR DOORS FRAME DOOR KICKS COOK 1, NO. WIDTH HEIGHT iHICKNESS TYPE MAT FIN MAT FIN HDW TYPE PLATE NOTES 1 3'-0" T-0" 1 3 4" EXISTING DOOR TO REMAIN UNCHANGED 1 a 2 3'-0" T-0" 1 3/4" A FG P HM P 2 �j� V PICK-UP ❑ ' -`� f#P cB. (¢¢�� E / `FLOOR 0 Ego OGLE DRAIN HARDWARE TYPE m T.. � rvw 1 EXISTING DOOR HARDWARE TO REMAIN UNCHANGED. o N 2 1 1/2 PAIR BALL-BEARING HINGES, LEVER LATCH SET W/PRIVACY LOCK, STOP. l� 4'-6" Y- " 3'- " TOBLE ALIGN w/WALL \� I SCULLERY SEATING BY _ _J sr racra CLOSURE NOTES: OTHERS,TYP. rTl� - a1. THE MAXIMUM UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS. LOUNGE A3.0 TYP. + a 2. ALL CLOSERS TO BE 5 POUNDS MAX. PRESSURE. �` 1RasN 3. THRESHOLDS TO BE 1/2" BEVELED EDGE MAX, PROVIDE SWEEPS®ALL THRESHOLDS +n sx 0P 3-4' reo•w r rw I{�1 CO'1P0° I I N p--q ��-�111 ddd�...r eEcrcL r Ih` J'I A A L w DRY e e s.m a e STORAGER MEN'S O UIOMEN'S L o 0 0 0 o wxrG cwaER A �DOOR TYPES 15'-0" 6'-0"CLR. CLR. TOTAL TRAVEL DISTANCE 95'<100'M o' SCALE: 1 14"-1' 0" BUILDING 1 FIRST FLOOR PLAN 0 2 4 8 2 SCALE: 1/4"-1'-O" 1/4"=1'-0 3 ♦�♦ `cit issue: 11-16-23 m title: sheet no. 1. GLENN 324 WEST BAY DRIVE NW date: 11-15-23 2 ♦ ♦ ♦ SUITE 214 38m9 RRCIH EC ����� WELLS drawn: R.C.T. FIRST FLOOR PLAN � , OLYMPIA, WA 98502 EDISON CAFE A1.0 . ..� GLENN C.WELLS W U .,' �.,. (360) 239-5971 ATE OF WASHINGTGN checked: G.C.,1. •ft= -- ARCHITECT - OLYMPIC AVE ..��at.��.. glennwellsarchitect�gmail.com Ex°.,E_,e_„ ARLINGTON, WASHINGTON s E u_ 3 LEGEND 2'X4'LED LIGHT TROFFER Q� TRACK LIGHT FIXTURE O PENDANT LIGHT FIXTURE �Q EXHAUST FAN IEXITI LIGHTED EXIT SIGN/EMERGENCY LIGHT C 0 0 0 0 WALK-IN C LER/FREZER C 0 0 0 OPEN�i0 ABO�J C CC CC 0FQ> aQ> 0 � C C C � a 0 0 �Ol-TR GLL16.CEILING, G1ll.�s;CEILING a u In In n In In 11 01 1 m ______ m 3 a H w x F N v v 11 2 4 8 12 BUILDING 1 FIRST FLOOR REFLECTED CEILING PLAN SCALE: 1/4"-1'-B" 1/4 1'-0", 3 ♦�♦ `cit issue: 11-16-23 title: sheet no. GLENN 324 WEST BAY DRIVE NW date: 11-15-23 ♦ • ♦ SUITE 214 3809 RE'0 FIRST FLOOR REFLECTED CEILING PLAN ' • • . GH EC drawn: R.C.T. ��•��� WELLS OLYMPIA, WA 98502 .;,.,,. GLENN WELLS EDISON CAFE A2.0 (360) 239-5971 ATE OF WASHINGTON checked: G.C.,1. •�= ARCHITECT - DLYMPIC AVE glennwellsarchitect�gmail.com E,,.,e_,e_„ IL ARLINGTON, WASHINGTON sof E u_ 3 LFG END REQUIREMENTS ENOTES ABBREVIATIONS GENERAL 1) ALL DEVICES, WIRING, AND INSTALLATION IS NEW, UNLESS NOTED OTHERWISE. GENERAL A AMPERE CONTRACTOR SHALL MAINTAIN POWER, DATA WIRING, AND FUNCTIONALITY OF ALL AC ALTERNATING CURRENT EQUIPMENT AND DEVICES DESIGNATED AS EXISTING TO REMAIN OR RELOCATED EXISTING. 1. PROVIDE ELECTRICAL INSTALLATION IN ACCORDANCE WITH AFC ABOVE FINISHED FLOOR LIGHT LINE INDICATES NON-ELECTRICAL OR BACKGROUND CONTRACTOR SHALL WARRANTEE ALL WORK FOR NO LESS THAN ONE YEAR. NATIONAL ELECTRICAL CODE, LOCAL CODES, AND ORDINANCES. AIC AMPS INTERRUPTING CAPACITY (THIS IS NOT CONTRACTUAL DEFINITION OF WORK) AL ALUMINUMAMP AMPERE Z 2) PROVIDE A MINIMUM SIZE OF 3/4" CONDUIT. AWG AMERICAN WIRE GAUGE z o HEAVY LINE INDICATES NEW WORK 2. PROVIDE ITEMS NECESSARY TO COMPLETE ELECTRICAL SYSTEMS. LLI O 5 (THIS IS NOT CONTRACTUAL DEFINITION OF WORK) 3) REFER TO ARCHITECTURAL SET FOR ALL RECEPTACLE MOUNTING HEIGHTS. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND DO NOT BKR BREAKER N a w NECESSARILY SHOW EVERY CONDUIT, BOX, CONDUCTOR OR DETAIL IDENTIFICATION OTHERWISE, ALL RECEPTACLES MTD 18" A.F.F. SIMILAR ITEMS FOR A COMPLETE INSTALLATION. BLDG BUILDING � U K N 4) REFER TO ARCHITECTURAL SET FOR ALL SWITCHES MOUNTING HEIGHTS. C COIL or CONDUIT a o SYMBOL NAME 3. WHEREVER THE WORD "PROVIDE" IS USED, IT MEANS, "FURNISH CRT CIRCUIT OTHERWISE, ALL SWITCHES MTD 48" A.F.F. AND INSTALL COMPLETE AND READY FOR USE." G CO CONDUIT/RACEWAY ONLY 5 ALL DEVICES TO MATCH BUILDING STYLES U.N.O. CT CURRENT TRANSFORMER < ) 4. VERIFY ALL FINAL ROOM NAMES AND NUMBERS WITH OWNER PRIOR � o DETAIL, DIAGRAM, OR PARTIAL PLAN TO PREPARING PERMANENT PANEL SCHEDULES. Cu COPPER 6) THE CONTRACTOR SHALL REFER TO THE STRUCTURAL, PLUMBING, HVAC, FIRE CW COOL WHITE PROTECTION, AND ARCHITECTURAL DRAWINGS BEFORE INSTALLING ANY ELECTRICAL 5. NOT ALL SYMBOLS AND ABBREVIATIONS ARE USED. D DIMMER EQUIPMENT. DED DEDICATED tSECTION 7) ALL WIRES, TERMINATIONS, & DEVICES SHALL BE RATED 75`C. ALL BRANCH CIRCUIT CIRCUITS WIRING, AND DISTRIBUTION FEEDERS SHALL BE COPPER WITH THHN/THWN INSULATION EXIST EXISTING UNLESS NOTED OTHERWISE. 1. BRANCH CIRCUIT CONNECTIONS ARE SHOWN FOR THE SOLE PURPOSE OF EF EXHAUST FAN OpO013 ALL DETAIL SYMBOLS CONTAIN INDICATING ALL OF THE DEVICES WHICH ARE TO BE CONNECTED TO A ELEC ELECTRICAL S... THE FOLLOWING INFORMATION: PARTICULAR BRANCH CIRCUIT. CONDUCTOR SIZES AND/OR QUANTITIES EMT ELECTRICAL METALLIC TUBING oFWgsti ,t. 8) ALL COMPONENTS FURNISHED BY THE CONTRACTOR SHALL BE UL LISTED FOR THEIR SEQUENTIAL CHARACTER (BY SHEET) INTENDED USE. ARE NOT INDICATED FOR 20 AND 15 AMP, BRANCH CIRCUITS. EQUIP EQUIPMENT ..�� 4'�A..((\ 3 CONDUCTOR SIZES AND/OR QUANTITIES ARE ONLY INDICATED WHERE ALPHABET - SECTIONS & ELEVATIONS OVERSIZED CONDUCTORS ARE REQUIRED TO MINIMIZE VOLTAGE FACE FIRE ALARM CONTROL PANEL p NUMBER - DETAILS & PARTIAL PLANS 9) CONTRACTOR SHALL PROVIDE FULLY RATED ELECTRICAL EQUIPMENT OF THEIR FLUOR FLUORESCENT NAMEPLATE VALUES. g DROP OR ON BRANCH CIRCUIT CONNECTIONS WHICH ARE NOT FED 1s 1 BY 15 OR 20 AMP CIRCUIT BREAKERS. THE ELECTRICAL CONTRACTOR 00" E- E-1 DRAWING CONTAINING SECTION, ELEVATION, 10 THE CONTRACTOR SHALL PROVIDE BOX, CONDUIT AND PULL STRING FOR SHALL DETERMINE RACEWAY ROUTING, GROUPING OF BRANCH CIRCUITS GND GROUND FAULT CIRCUIT INTERRUPTER �AL\ 23 PARTIAL PLAN, OR DETAIL COMMUNICATION CABLES. COORDINATE WITH SECURITY AND COMM DATA VENDORS AND FOR JUNCTION NUMBERS OF CONDUCTORS REQUIRED AND PLACEMENT GRS GALVANIZED RIGID STEEL 1,16' / OF JUNCTION BOXES. SHOW ACTUAL RACEWAY ROUTING AND CIRCUITING 1 DRAWING CONTAINING PLAN AT WHICH SECTION, DETERMINE REQUIREMENTS. ON RECORD DRAWINGS. ELEVATION, PARTIAL PLAN, OR DETAIL APPLIES HID HIGH INTENSITY DISCHARGE (NOT ALWAYS USED) 11) ALL WIRING SHALL BE ROUTED PERPENDICULAR TO COLUMN LINES. 2. PROVIDE #10 CONDUCTORS IN LIEU #12 IN 20A CIRCUIT HOMERUNS HP HORSEPOWER r LONGER THAN 75 FEET. - ' FLAG NOTE 12) CONTRACTOR SHALL COORDINATE ELECTRICAL SYSTEM SHORT-CIRCUIT WITHSTAND KCMIL THOUSAND CIRCULAR MILLS AND INTERRUPT WITH THE SHELL ELECTRICAL SYSTEM AND DESIGN. LIGHTING KVA KILOVOLT AMPERES KW KILOWATT ' REVISION NOTE 13) CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION & 1. SUPPORT LIGHT FIXTURES FROM BUILDING STRUCTURE. DO NOT LTG LIGHTING ROB1SON QUANTITIES OF ALL DEVICES. SUPPORT FIXTURES FROM SUSPENDED CEILING. LV LOW VOLTAGE ENGINEERING,INC REVISION DEFINITION. AREA ENCIRCLED 2. PROVIDE LIGHT FIXTURES WITH PROPER FITTING FLANGES, a01 noTH Avew.sulTs3c� CID14) CONTRACTOR SHALL MATCH BUILDING STANDARDS FOR ALL ELECTRICAL DEVICES, MFR MANUFACTURER NNWOOOWADJITE CONTAINS DRAWING CHANGES MADE MOUNTING SUPPORTS, AND ACCESSORY ITEMS, UL LISTED FOR Lv SUBSEQUENT TO PREVIOUS ISSUE COVER PLATES, RECEPTACLES AND THE LIKE. TRIMS, FINISHES AND COLORS SHALL BE MIN MINIMUM 20636633E3m COORDINATED THROUGH THE ARCHITECT. CONDITIONS OF USE. MLO MAIN LUGS ONLY Rnrnc�'c�L�eocX. AD 3. THE MAXIMUM LIGHTING POWER THAT MAY BE CONTROLLED FROM N NEUTRAL 15) CONTRACTOR SHALL GUARANTEE ALL WORK PERFORMED AS PART OF THIS A SINGLE SWITCH OR AUTOMATIC CONTROL SHALL NOT EXCEED NEC NATIONAL ELECTRICAL CODE (NFPA-70) LIGHTING CONTRACT IS FREE FROM DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF THAT WHICH IS PROVIDE BY A TWENTY AMPERE CIRCUIT NEMA NATIONAL ELECTRICAL MANUFACTURERS SUBSTANTIAL COMPLETION. EC SHALL REPLACE OR REPAIR ANY DAMAGED OR DEFECTIVE LOADED TO NOT MORE THAN EIGHTY PERCENT. A MASTER ASSOCIATION DEVICES OR WORK FREE OF CHARGE DURING THIS PERIOD. CONTROL MAY BE INSTALLED PROVIDED THE INDIVIDUAL SWITCHES NTS NOT TO SCALE F2 FIXTURE IDENTIFICATION SYMBOL RETAIN THEIR CAPABILITY TO FUNCTION INDEPENDENTLY. PNL PANEL a = of SEE LUMINAIRE SCHEDULE FOR FIXTURE SYMBOLS 16) A MANUFACTURER'S SPEC SHEET(INCLUDING CATALOG NUMBER AND SHOP POC POINT OF CONNECTION g g w DRAWINGS) SHALL BE SUBMITTED FOR APPROVAL ON ALL DISTRIBUTION RACEWAYS AND 4. CIRCUIT BREAKERS MAY NOT BE USED AS THE SOLE MEANS PT POTENTIAL TRANSFORMER WIRING, FIXTURES, DEVICES AND EQUIPMENT PRIOR TO PURCHASING. OF SWITCHING. PVC POLYVINYL CLORIDE PWR POWER z z w O Y 17) ALL WIRING SHALL BE IDENTIFIED WITH PANELBOARD AND CIRCUIT NUMBERS IN ALL a N w a JUNCTION BOXES, TROUGHS, POINTS OF TERMINATION, ETC. QTY QUANTITY GROUNDING SWITCHES RECEPT RECEPTACLE 18) CONTRACTOR SHALL CLEAN, VACUUM & TIGHTEN ALL CONNECTIONS FOR ALL ELECTRICAL DISTRIBUTION EQUIPMENT THAT IS TO BE RE-USED 1. GROUND ALL ELECTRICAL DEVICES, MOTORS, METALLIC PIPING, RI ROUGH-IN . $0 SWITCH, SINGLE POLE; WITH SWITCHING SUBSCRIPT DUCTWORK, METAL FRAMING, REINFORCING STEEL, ETC., IN RM ROOM ACCORDANCE WITH NEC ARTICLE 250. RO RACEWAY ONLY $M THERMAL OVERLOAD MOTOR STARTER SWITCH 19) ALL KNOCKOUTS IN ALL ENCLOSURES SHALL BE SEALED. UTILIZE THE METALLIC RACEWAY SYSTEMS AS THE SYSTEM GROUNDING PATH FOR ALL DEVICES UNLESS OTHERWISE SHT SHEET $ SWITCH, SINGLE POLE; WITH SWITCHING SUBSCRIPT 20) CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN UPDATED TYPED CIRCUIT NOTED. PROVIDE SEPARATE GREEN GROUNDING CONDUCTOR FOR SPEC SPECIFICATIONS° DIRECTORY FOR ALL PANELBOARDS THAT ARE AFFECTED BY THE CONSTRUCTION. ALL FLEXIBLE EQUIPMENT CONNECTIONS AND ALL EXTERIOR SW SWITCH D "D" INDICATES WALLBOX DIMMER ELECTRICAL DEVICES, SUCH AS POLE MOUNTED LIGHTING, SWBD SWITCHBOARD 21) CONTRACTOR SHALL PROVIDE ENGRAVED NAMEPLATES FOR ALL PANELBOARDS, RECEPTACLES, BUILDING MOUNTED LIGHTING, ETC. SWGR SWITCHGEAR SWITCH & CONTROLLED OUTLET OR FIXTURE JUNCTION BOXES, DISCONNECT SWITCHES AND TRANSFORMERS. TYP TYPICAL ® RELAY 22) CONTRACTOR SHALL CROSS REFERENCE AND IDENTIFY ALL EQUIPMENT THAT UG UNDERGROUND REQUIRES ELECTRICAL AND FIRE ALARM SERVICE WITH ALL OTHER TRADES.$T SWITCH WITH TWIST TIMER LIGHTING CONTROL COMMISSIONING UL UNDERWRITERS LABORATORIES ('')22) CONTRACTOR SHALL REVIEW PROJECT SPECIFICATIONS FOR ALL ELECTRICAL WORK. 1. OCCUPANCY SENSORS, PHOTOCELLS, CONTACTORS AND OTHER LON UNLESS OTHERWISE NOTED w Cv $os VACANCY SENSOR WALL SWITCH LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT V VOLTS � CO 23) CONTRACTOR SHALL UTILIZE THE MOST STRINGENT SPECIFICATIONS IN THESE CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS Cr, DOCUMENTS. IF THERE ARE ANY CONFLICTS OR CONTRADICTIONS, THE MOST STRINGENT ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE SPECIFICATIONS SHALL APPLY. WITH APPROVED PLANS AND SPECIFICATIONS. WW WARM WHITE OS >Q CEILING MOUNTED OCCUPANCY SENSOR WP WEATHERPROOF U > Fw 2. SUBMIT A REPORT OF TEST PROCEDURES AND RESULTS TO WHO WITHOUT �( tomo v PS a PHOTOSENSOR FOR DAYLIGHT ZONE. LETTER THE OWNER. WSNREC WASH. STATE NONRESIDENTIAL W b 3 m INDICATES LIGHTING ZONE CONTROLLED BY SENSOR ENERGY CODE a RECEPTACLES 0= =p XFMR TRANSFORMER F O o IQ DUPLEX RECEPTACLE XFR TRANSFER w Q 3 N Z IMPEDANCE OR ZONE 0 3 z O ICE GFCI DUPLEX RECEPTACLE WITH GROUND FAULT CIRCUIT [L rn za INTERRUPTER (GFCI). INDICATES MOUNTING HEIGHT SHOWN. V) CJ CLG SHOW WINDOW RECEPTACLE 7 Q Z $ CEILING MOUNTED DUPLEX RECEPTACLE L ® SPECIAL EQUIPMENT O V Z CD j CONTROLLED RECEPTACLE DRAWING INDEX �1 Ln � o mZ OTHER O ® SPECIAL HARDWIRED ELECTRICAL CONNECTION o Z 0' FUSED DISCONNECT SWITCH a w JO JUNCTION BOX LOW VOLTAGE EQUIPMENT FOR REFERENCE INCLUDED IN SET DATE: 11/15/2023 ONLY. CONFIRM WITH LOW VOLTAGE VENDOR V BROADBAND OUTLET - SHEET TITLE: TELEPHONE OUTLET DWG DESCRIPTION E0.00 LEGEND,GENERAL NOMS,DRAWING INDEX X LEGEND,GENERAL E1.o0 NOTES,DRAWING E1.11 PHOTOMETRICN IAII PLAN_ - AIN N INDEX E},01 POWER PLAN-ROOF E5.00 ONE-LINE DIAGRAM SHEET NO. E0.00 LUMINAIRE SCHEDULE GENERAL LIGHTING NOTES T LIGHTING CONTROLS SHALL BE INSTALLED WHICH MEET ALL REQUIREMENTS OF LOCAL ENERGY CODES. CALLOUT SYMBOL MOUNTING DESCRIPTION MODEL VOLTAGE TYPE LAMPING WATTAGE NOTES 2. EMERGENCY LIGHT FIXTURES:PROVIDE UNSWITGHED HOT. 3. LOCATIONS OF OCCUPANCY SENSORS,PHOTO SENSORS,DIMMERS,AND SWITCHES ARE DIAGRAMMATIC. Al SURFACE 4" CYLINDER PENDANT DIVE: DC4 C2 S S D 12 FL 0 00 00 40 120 0-10V DIMMING (1) 14W LED 14 90 / 4000K CONTRACTOR TO COORDINATE QUANTITIES AND OPTIMAL LOCATIONS WITH LIGHTING CONTROL [FINISH] 0 OO R DGGX-J MANUFACTURER AND ARCH/OWNER. 4. AUTOMATIC LIGHTING SHUT-OFF CONTROLS SHALL BE PROVIDED BY LOCAL OCCUPANCY SENSORS UNLESS 60 OTHERWISE NOTED.PUBLIC SPACES ARE ACTIVE 24/7 AND THEREFORE EXEMPT FROM AUTOMATIC LIGHTING Z A2 SURFACE DCCxxxx4D-15F-0000-30-Wx T9MF Lighting, 120 0-10V DIMMING (1) 14W LED 18.7 90 / 4000K SHUT-OFF REQUIREMENTS FOR SECURITY(WSEC C405.2) o DCCxxxx4D-15F-0000-30-Wxx-R z GO 5. DAYLIGHT ZONES ARE SHOWN ON PLANS AS DEFINED BY WASHINGTON STATE ENERGY CODE(WSEC) W o j C405.2.4.2.SIDELIGHT DAYLIGHT ZONES ARE REFERRED TO AS'PRIMARY AND'SECONDARY ON PLANS AND o H- W B1 RECESSED GR 2'X4' LED TROFFER w/ F1 COOPER LIGHTING SOLUTIONS - METALUX 120 0-10V DIMMING (1) 56W 3500K 48.7 80 / 3500K DENOTED BY DASHED LINES. CL EC LENS (FORMERLY EATON), CCT, 80 CRI F� 6. FOR CUSTOM FF&E FIXTURES,IT IS THE MANUFACTURER'S RESPONSIBILITY TO FURNISH PRODUCTS WHICH U 24GR-LD5-72-F1-UNV-L835-CD1-U LEDS ARE COMPLIANT WITH ALL REQUIREMENTS OF LOCAL ENERGY CODES,AS WELL AS MATCH THE ELECTRICAL CC 00 SPECIFICATIONS PROVIDED IN THE LUMINAIRE SCHEDULES.PROVIDE SUBMITTAL SHOP DRAWINGS WITHIN 30 Lj d LJ B2 RECESSED 1X4 TROFFER - LAUNDRY / COOPER - METALUX: 14GR LDS 72 F1 120 0-10V DIMMING (1) 56W LED 56 80 / 3500K DAYS OF RECEIVING FIXTURE ORDER,SUBMITTALS SHALL CLEARLY INDICATE LAMPING AND MAXIMUM WATTAGE RATING OF LAMP SOCKETS.NON-COMPLIANT FIXTURES REJECTED BY ELECTRICAL INSPECTOR FOOD PREP /HOUSEKEEPING UNV L835 CD1 U SHALL BE RETURNED TO THE MANUFACTURER FOR REWORKING AND/OR RE-LABELING. ]. ALL FIXTURES SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. \ ¢ BATTERY BACKUP - HATCH X1 ® SURFACE EXIT SIGN EMERGENCY LSI: EMS WE SERIES (OR EQUAL) MULTIPLE EM (1) SW EM 5 EM / EM 8. CONTRACTOR SHALL BE RESPONSIBLE TO ORDER ALL NECESSARY HARDWARE,ELECTRICAL CABLE,TIMERS,INDICATES LIT FACE TRANSFORMERS,ETC.,AS REQUIRED FOR COMPLETION OF INSTALLATION OF A FULLY FUNCTIONING SYSTEM. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR EQUIPPING ALL FIXTURES WITH THE EXACT LAMPS SPECIFIED IN THE FIXTURE SCHEDULE. � Z 10.WHERE FIXTURES REQUIRE REMOTE TRANSFORMERS OR BALLASTS,THE CONTRACTOR SHALL DETERMINE LOCATIONS AS REQUIRED FOR EVEN LOAD DISTRIBUTION,SERVICE ACCESS,AND VENTILATION. 11,THE CONTRACTOR SHALL COORDINATE WITH THE ELECTRICAL ENGINEER FOR EXACT LOCATIONS OF TIMERS 130 AND/OR PHOTO CELLS,IF ANY. 12.WHERE APPLICABLE,THE CONTRACTOR SHALL AIM AND ADJUST LIGHTING FIXTURES AS DIRECTED BY THE ............ y LIGHTING DESIGNER UPON COMPLETION OF THE INSTALLATION. SPECIAL NOTE TO THE CONTRACTOR m (� pAo 13 O 1. FIXTURE SUBMITTALS THAT DO NOT INCLUDE LAMP SPECIFICATIONS WILL BE CONSIDERED INCOMPLETE AND O WILL NOT BE RENEWED. 155 �p O LIGHTING CONTROL SYSTEM REQUIREMENTS Do �A\ 23 1. CONTRACTOR TO PROVIDE A FULLY OPERATIONAL LIGHTING CONTROL SYSTEM. 1/ 2. CONTRACTOR SHALL VERIFY THE COMPATIBILITY OF DIMMING AND CONTROL MODULES WITH FIXTURE TYPES PRIOR TO INSTALLATION. 3. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH A LIGHTING CONTROLS VENDOR TO OBTAIN LIGHTING rn CONTROL SYSTEM PACKAGE COMPLETE WI1H DEVICES,WIRING DIAGRAMS,ANNOTATED PLANS INDICATING " ~ WHICH DEVICE TO BE USED IN EACH LOCATION,CONNECTEN REQUIREMENTS,SET UP INSTRUCTIONS, COMMISSIONING AND CHECK-OUT FOLLOWING COMPLETION.PROVIDE ALL LOW VOLTAGE WIRING AS REQUIRED FOR CONTROL DEVICE INTERCONNECTIONS. 4. INSTALLER QUALIFICATIONS:TECHNICIAN INSTAWNG AND WIRING THE LIGHTING CONTROL SYSTEM SHALL o B i s o ry HAVE INSTALLED THIS SAME SYSTEM AT LEAST ONCE PREMOUSLV,TECHNICIAN SHALL HA RECEIVED R TRAINI VE NO BY FACTORY REPRESENTATIVE ON THE SYSTEM BEING INSTALLED. 5. PROVIDE LIGHTING CONTROL SYSTEM TO PERFORM THE FUNCTIONS DESCRIBED BELOW: ENGINEERING,INC 40TH AVE W.,SUITE3c2 5.1. PROVIDE MULTI-SCENE DIMMING SCHEDULING AND CONTROL.INSTALLER TO COORDINATE SCENE Y NNWOOD,WA-6 CON FIGURATIONS WITH BRAND AND PROPERTY MANAGER. 20636b3343m 5.1.1. PROVIDE KEYPAD CONTROLS STATIONS FOR SELECTING LIGHTING SCENES AND FOR MANUAL ON/OFF REIPROJECTNO.:96— AND MULTI-LEVEL LIGHTNG CONTROL.REFER TO PLANS FOR KEYPAD LOCATIONS. CONTACT PETERROCKsTEND 5.2. LIGHTING CONTROL SCHEDULE:PROVIDE SEPARATE SWITCHING AND DIMMING CONTROL FOR LIGHTING ZONES AS INDICATED. 5.3. AUTOMATIC LIGHTING CONTROLS: 5.3.1. UNLESS OTHERWISE NOTED ON PLANS,OCCUPANCY SENSORS SHALL AUTOMATICALLY TURN OFF ALL CONNECTED LIGHTING WITHIN 30 MINUTES OF SPACE BEING UNOCCUPIED.OCCUPANCY SENSORS SHALL EITHER BE MANUAL ON OR SHALL BE CONTROLLED TO AUTOMATICALLY TURN THE LIGHTING m m LO ON TO NOT MORE THAN 50 PERCENT POWER EXCEPT WHERE MANUAL ON WOULD ENDANGER THE W EL = Of SAFETY OR SECURITY OF THE ROOM OR BUILDING OCCUPANTS.(C405.2.1.1) LL 53.2. MULT-ZONE PHOTO-SENSORS SHALL PROVIDE SEPARATE CONTROL FOR LUMINAIRES IN EACH TYPE OF DAYIJGHT ZONE.(C4O5.2.4A) 5.3.3. EXTERIOR LIGHTING CONTROLS SHALL AUTOMATICALLY TURN OFF LIGHTING AS A FUNCTION OF o W AVAILABLE DAYLIGHT.BUILDING FACADE AND LANDSCAPE LIGHTING SHALL HAVE CONTROLS THAT Z Z LO oAUTOMATICALLY SHUT OFF THE LIGHTING AS A FUNCTION OF UAWN/DUSK AND A SET OPENING 3 o U EC TIME AND CLOSING TIME.OTHER LIGHTING SHALL HAVE CONTROLS CONFIGURED TO AUTOMATICALLY ¢ N W W REDUCE THE CONNECTED LIGHTING POWER BY AT LEAST 30 PERCENT FROM NO LATER TITAN 12 O_ W = LL MIDNIGHT TO 6 AM OR FROM ON HOUR AFTER BUSINESS CLOSING TO ONE HOUR BEFORE BUSINESS O p U ¢ OPENING OR DURING ANY PERIOD WHEN NO ACTIVITY HAS BEEN DETECTED FOR A TIME OF NO LONGER THAN 15 MINUTES.(C405.2.7) 6. DURING EMERGENCY CONDITIONS EMERGENCY LIGHTING CIRCUITS SHALL BYPASS ALL LIGHTING CONTROLS IN ORDER TO ENERGIZE ALL CONNECTED LUMINAIRES AT FULL CAPACITY.PROVIDE UL924 RELAYS AS REQUIRED TO BYPASS AREA CONTROLS. 6.1. EMERGENCY PATHWAY EGRESS LIGHTING:ILLUMINATION PROVIDED ALONG THE EGRESS PATH AT FLOOR LEVEL SHALL AVERAGE AT LEAST 1 FOOT CANDLE.(SBC 1008.3.5) 6.2. EMERGENCY LIGHTING SHALL BE SUPPLIED BY:TBD EXIT SIGN NOTES DURING CONSTRUCTION UPON COMPLETION OF A TYPICAL FLOOR FRAMING AND BEFORE WALL COVER, ELECTRICAL CONTRACTOR SHALL WALK THE EGRESS PATHS WITH THE LOCAL INSPECTOR(AHJ)TO CONFIRM THAT ALL THE EXIT SIGNS ARE LOCATED PER THE AHJ'S SATISFACTION AND IDENTIFY ANY ADDITONAL EXIT C'7 SIGNS THAT THE AHJ WISHES TO BE INSTALLED(IBC 1013.1).CONTRACTOR SHALL PROVIDE UP TO 10% ADDITIONAL EXIT SIGNS AT NO ADDITIONAL COST. w N U— co 01 LIGHTING CONTROLS LEGEND Q < N �A TOGGLE SWITCH FOR MANUAL ON/OFF LIGHTING CONTROL SUBSCRIPT INDICATES WHICH UW �D FIXTURES ARE TO BE CONTROLLED BY WHICH SWITCH.(WSEC C405.2.3) GO cp N o CO 06 O 3DOM a DIMMER SVATCH FOR MANUAL MULTI-LEVEL LIGHTING CONTROL.SWITCH SHALL ALSO HAVE DUUO ¢ IWII MANUAL ON/OFF FUNCTIONALITY.SUBSCRIPT INDICATES WHICH FIXTURES ARE TO BE ¢GO m CONTROLLED BY WHICH DIMMER.(C405.2.3) J H cl 0 uj Q ,3 N IaI SWITCHES LABELED'OS'SHALL TURN OFF ALL CONNECTED LUMINAIRES WITHIN 30 MINUTES OF Q p 2 0 SPACE BEING VACANT.(C405.2.1.1) z a TIP WALLBO%DIMMER OR SWITCH FOR MANUAL LOCAL LIGHTING CONTROL.WALLBOXES SHALL ALSO U A HAVE MANUAL ON/OFF FUNCTIONALITY OF ALL CONNECTED LUMINAIRES.SUBSCRIPT INDICATES Z ®® WHICH FIXTURES ARE TO BE CONTROLLED BY ZONE ACCORDING TO LIGHTING CONTROL Z Q SCHEDULE(130.1(b)).SUBSCRIPT'TR'INDICATES TAMPER RESISTANT CONTROLS TO BE O C ACCESSED BY AUTHORIZED PERSONNEL ONLY. C O w ® MINUTESCY OF SPACERBENGL VACANT.ATICALLY(C404.2.1NRN OFF ALL CONNECTED LUMINAIRES WITHIN 30 //1 O U) vZ Ln 0 CD ® MUTLIZONE PHOTOSENSOR FOR DAYLIGHT ZONE CONTROL SHALL AUTOMATICALLY ADJUST THE N W LIGHT OUTPUT OF ALL CONNECTED LUMINAIRES BASED ON THE DAYLIGHT LEVEL IN THE LIJ PRIMARY AND SECONDARY ZONES.(C405.2.4) O LO U a W DATE: 11/15/2023 SHEET TITLE: LUMINAIRE GENERAL NOTES, SCHEDULES SHEET NO. E 1 .00 COPYRIGHT 2023.ROBISON ENGINEERING,INC MBENZAR E\1131-003 JUST POKE IN SNON ISH,WA\DWG\E3.W POINER.M 04-28 2023 12:24 GENERAL NOTES 1. EMERGENCY EGRESS LIGHTING: TDD. 2. REFER TO SERIES E3.00 DRAWINGS FOR ELECTRICAL AND PANEL LAYOUT. 3. SEE SHEET E1.00 FOR LUMINAIRE SCHEDULE AND LIGHTING NOTES. � FLAG NOTES o N O 1. EXIT SIGNS: PROVIDE UNSWITCHED HOT. IN ADDITION TO N w STANDARD HIGH LEVEL EXIT SIGNS, PROVIDE LOW LEVEL EXIT a SIGNS IN ALL INTERIOR CORRIDORS OF GROUP R, DIVISION I 5 (6.7 7 (7.5 8 OCCUPANCIES AS INDICATED ON PLAN. (TYP) (IBC 1013.2) w w a o 2. PROVIDE TAMPER RESISTANT LIGHTING CONTROLS. (TYP) a . . . . . . . . > o 0 z P..S... O ._X A O ° g` o T ° � g `a�/CNAL '\p0� 38 38 38 f3 (40 �O°°°°1 5�23 T T T T Al Al Al 38 T 38 T 38 RoBisory ENGINEERING,INC amN.—s11-02 O TB1 NNJl000,WA9B036 A2 40 LY 20636b33E3m REIPROJECTN0.:9fi2020 38Fff D 40 D 1 Al Al r44 a 38 38 38 o 0 0 q0 � d =TT o o Q o 3 v �JF- A2 A2 � � w = a a o o U a 38 G A2 38 COED 8 38 03 38 3 F A8 F OL a UJ M CV Al Al Al LL co G Q 01 N U � dS ° W MCI LU Q o0N,p3� z IL °'na 5 7 8 Z D ZZ 0 0 � (f) Z Ln C) CD 0-1 rx W cr) m W w 0 � LlW DATE: 11/15/2023 SHEET TITLE: LIGHTING PLAN- MAIN LIGHTING PLAN - MAIN SCALE: 1/4" = 1'-0" N SHEET NO. El .01 COP—T 2023,ROBISON ENGirvEENNG,INC, BBENEAR F:\1131-003 JJST POKE IN SNOxWiSN,wA\DK\E3.W POKERDC 04-28-2023 12:24 GENERAL NOTES 1. EMERGENCY EGRESS LIGHTING: TBD. 2. REFER TO SERIES E3.00 DRAWINGS FOR ELECTRICAL AND PANEL LAYOUT. 3. SEE SHEET E1.00 FOR LUMINAIRE SCHEDULE AND LIGHTING NOTES. FLAG NOTES o z N 1. EXIT SIGNS: PROVIDE UNSWITCHED HOT. IN ADDITION TO N w STANDARD HIGH LEVEL EXIT SIGNS, PROVIDE LOW LEVEL EXIT a SIGNS IN ALL INTERIOR CORRIDORS OF GROUP R, DIVISION I 5 (6.7 T (7.5 8 OCCUPANCIES AS INDICATED ON PLAN. (TYP) (IBC 1013.2) w w a o 2. PROVIDE TAMPER RESISTANT LIGHTING CONTROLS. (TYP) a > o 0 z Egress Photometric S.T.. ® II II ® O Schedule OF`ly4SN I O ule ° '�`` ti°gm 13 S 10.5 ched AVERAGE 23.63 FOOT-CANDLES 209 9.7 5.9 16.9 O 17.0 6.1 10.1 204 O MAXIMUM 64.5 o`a��CNA \ 23 FOOT-CANDLES �OOO°1°1,15� Ion MINIMUM .2 FOOT-CANDLES 10.6 0 MINIMUM TO MAXIMUM .10 O O O O FC RATIO 6 9 MAXIMUM TO MINIMUM 10.45 FC RATIO ROTOR' AVERAGE TO MINIMUM 3.83 ENGINEERING,INC FC RATIO 1nmNA .s11 E 2 O NNJl000WA9B0, 36 LY R0636b33E3m REIPROJECTN0.:9fi2020 O D D CONTACT P-ROC-EAD O O O o o�' m m N 6.4 0 0 0 o w U a in w a 6.9 4.6 4.0 6.9 5.5 4.0 7.0 10.2 18.5 O 20.2 o o O 16.5 O O O 0 COED LO 18.4 O 0 n n F F Ell71) O O O (0 w CN LL CO G Q O, o U � 06 a LU 000 Q �p3� Q w z IL ° a 5 7 8 Z L) ZZ o 0 (f) Z Ln 0 CD LJJ cr m W w 0 � LW DATE: 11/15/2023 SHEET TITLE: PHOTOMETRIC PLAN-MAIN PHOTOMETRIC PLAN - MAN SCALE: 1/4" = 1'-0" N SHEET N0. E1 . 11 COP-T 2023.ROBISON ENGNEWN6,INC, BBENEAR F:\1131-003 JJST POKE IN SNOxWiSN,wA\DK\E3.W POKERM 04-28-2023 12:24 11/14/23,3:25 PM waenergycodes.com/print_lroject_summary_form.php?k=aWQ9MjlxMjgmZnZpPTE4JnJlc2VOPTE=&debug=1 IGHTIN 2018 WSEC Compliance Forms for Commercial Buildings including Group R2,R3&R4 over 3 stories and all Rl Administered by:m2023 NEEA,All rights reserved Project Title Edison's Cafe-2018 WSEC For Building Department Use: I Date: NOV 14,2023 2505 Olympic PI zo Project Address Arlington,WA,WA 98223 z N Project&Applicant Sth> o Information Applicant Name Matthew Benzar N w a e Applicant Phone 206-364-3343 � it Applicant Email mbenzar@robisonengineering.com w w For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com a General Occupancy All Commercial General Building Use Type Dining,Restaurant Building Cond.Floor Area 1,912 a New Building or Project Cond.Floor Area 1,912 = Alteration General Project Types Tenant Spaces—Fast Build Out Addition Interior Lighting Lighting Scope Floors Above Grade 1 Lighting Scope Compliance Method Compliance Method 1-General z Lighting Project Description Small Cafe at the bottom of an apartment building. Interior/Exterior �C STF7 Lighting Compliance LPA Calculation Compliance !1' Scope g p Project Type [Interior&parkin�h Interior Luminaire Replacement Scope Compliance Method Adjustment Verification °Fti'p�Am° and Method Tenant Spaces—First Build Out Interior Lighting Building area No Calculation Adjustments selected COMPLIESIR Edison's Cafe-2018 WSEC icNAL \ oo°°°tm� 1 y,23 Lighting Power Calculation TENANT SPACES—FIRST BUILD OUT-INTERIOR LIGHTING Compliance Verification COMPLIES Compliance Method Building area LPA Calculation Adjustment none Interior Lighting Power Allowance-Building Area Building Areas Gross Interior Area(SF) LPA(Watts/SF) Total Watts Allowed Total Proposed Watts Compliance Status by (SF x LPA x l) By Building Area Building Area RO B I SO N Dining-Cafeteria/fast food 1 1,912 1 0.72 1 1,377 1 594 1 COMPLIES ENGINEERING,INC 1e 10THA ew' - Proposed Lighting Power Density LP 206°b63ias Total Watts I CO'Ne'TA'C.TJP'c�ENR.RO'CK"�"AD Watts per Proposed Fixture New or Existing-to- Quantity of Fixtures, Fixture,CLD Total Watts per (#F x WpF) e/A hcation Fixture ID Building Area Remain CLDs or or Linear Linear or PP Luminaires(#F) Luminaire Feet(LF) Foot(WpLF) (LF x (WpF) WpLF) m m cn Individual Fixtures a Direct/indirect Dining-Cafeteria/fast o pant DMF:DC4 C2 S S D 12 FL 0 00 00 40[FINISH]O 00 R DCCX-J food New 11 14 154 0 0 COOPER LIGHTING SOLUTIONS-METALUX(FORMERLY EATON), Dining-Cafeteria/fast 3 cY.3 Of Troffer 24GR-LD5-72-Fl-UNV-L835-CD1-U food New 2 56 112 w = a O � U Q Troffer COOPER-METALUX:14GR LD5 72 Fl UNV L835 CDl U Dining-Cafeteria/fast New 1 56 56 Recessed downlight DMF Lighting,DCCxxxx4D-15F-0000-30-Wxx-R Dining-f Cafeteria/fast New 14 19 262 od Edison's Cafe-2018 WSEC Date Nov 14,2023 Proposed Fixtures Details ENANT SPACES-FIRST BUILD OUT Fixture Type/Application Fixture ID Location in Documents Lamp Type Building Area New or Existing-to-Remain https://waenergycodes.com/print_project_summary_form.php?k=aWQ9MjlxMjgmZnZpPTE4JnJlc2VOPTE=&debug=l 1/2 t ) UJ CV LL oo Q o1 11/14123,3:25 PM waenergycodes.com/print�roject_summary_form.php?k=aWQ9MjlxMjgmZnZpPTE4JnJlc2VOPTE=&debug=1 Q>> N Individual Fixtures U w Direct/indirect pendant DMF:DC4 C2 S S D 12 FL 0 00 00 40[FINISH]O 00 R DCCX-J E 1.00 LED Dinin -Cafet a/fastfoodl New Fixture Description:PENDANT Are these fixtures located within a daylight zone?:No t7() O W m m Do these fixtures require specific application lighting controls?:None required a Troffer COOPER LIGHTING SOLUTIONS-METALUX(FORMERLY EATON),24GR-LD5-72-Fl-UNV-L835-CDl-U E1.00 LED Dining-Cafeteria/fast food New J C F o 0 Fixture Description:BOH 2X4 TROFFER Are these fixtures located within a daylight zone?:No w °o w Do these fixtures require specific application lighting controls?:None required Q o z z 0 Troffer COOPER-METALUX:I4GR LD5 72 Fl UNV L835 CDl U EL00 LED Dining-Cafeteria/fast food New n a Fixture Description:BOH 1X4 TROFFER Are these fixtures located within a daylight zone?:No _ U Do these fixtures require specific application lighting controls?:None required Z Q Z z Recessed downlight DMF Lighting,DCCxxxx4D-15F-0000-30-Wxx-R E.100 LED Dining-Cafeteria/fast food New 0 E O Fixture Description:RECESSED DOWNLIGHT Are these fixtures located within a daylight zone?:No t- i9 Do these fixtures require specific application lighting controls?:None required O (n Z QCD N mw w w c U ��7 a w DATE: 11/15/2023 SHEET TITLE: LIGHTING COMPLIANCE FORMS SHEET NO. El .50 COP—T 2023.ROBISON ENCnEWNO,INC, KGENEAR P:\1131-003 JJST POKE IN SNONWiSH,wA\DK\E3.W POKERDw 04-28-2023 12:24 F- ' SHEET NOTES: I 1. PER 2020 NEC 210.8(B): ALL 50 AMPS OR LESS SINGLE PHASE RECEPTACLES RATED 150V TO GROUND OR LESS&ALL 100 AMPS OR LESS,THREE PHASE RECEPTACLES RATED 150V TO GROUND OR LESS WITHIN KITCHEN,BATHROOM,ROOFTOP,OUTDOORS,SINKS, AND INDOOR WET LOCATIONS SHALL HAVE GFCI PROTECTION AT THE PANEL OR AT THE RECEPTACLE 2 PROVIDE CONDUIT,WIRING,CIRCUITS AND CONNECTIONS AS COORDINATED WITH SECURITY VENDOR FOR FULLY FUNCTIONING SECURITY AND ACCESS CONTROL SYSTEM.COORDINATE WITH L ' SECURITY CONSTRUCTION DOCUMENTS TO IDENTIFY ALL CAMERA LOCATIONS,AT ALL DOORS CALLED OUT BY OWNER. N 3. AMENITY SPACES,OFFICES AND PUBLIC AREAS: ROUGH-INFOR 0 EQUIPMENT,OUTLETS AND APPLIANCES IN AMENITY SPACES BE COORDINATED WITH ARCHITECT.REFER TO ARCHITECTS DRAWINGS Z AND ELEVATIONS. W O > 4. (000NTRACTOR TO COORDINATE DOOR CONTROLS AND CONNECTIONS O_ Of WITH DOOR VENDOR,PROVIDE RACEWAY,CONDUCTORS,POWER U SUPPLY AND TERMINATIONS FOR A FULLY FUNCTIONING SYSTEM. 7 7 (7 8 COORDINATE NTH SECURITY VENDOR FOR MONITORING AND w CONTROL AS NEEDED. d o S. ELECTRICAL CONTRACTOR(EC)TO PROVIDE J-BOX/PULL BOX 50 w NUMBER OF BENDS IN CONDUIT DOES NOT EXCEED CODE REQUIREMENT(360 MAX TOTAL).EC TO FIELD VERIFY LOCATION OF Q ' A-42 J-BOX/PULL BOX.COORDINATE WITH ARCHITECT WHERE ACCESS = #10 117 PANEL IS REQUIRED. 0 A 7 A 9 C FLAG NOTES: ® z O (NOT EVERY FLAG IS USED ON EVERY SHEET) 1. SERVICE RECEPTACLES MUST BE WITHIN 25'OF HVAC EQUIPMENT, OOOpO ST 0000 II 94 II CONTRACTOR RESPONSIBLE TO COORDINATE LOCATION WITH HVAC II II A 12 1.1 1 HOVAIC EQUIPMEO TT FRAMEWORK.MAY MOUNT THE RECEPTACLES ON THE �pF yCA��QOO O 2. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR - g a PRIOR TO INSTALLATION. O A-30 FCU-1 ,5 3. COORDINATE PUMP ROUGH-IN,CONTROLLER LOCATION AND 13 OO 0.73K VA,208V2P2W A-10 CONDUITS FOR PUMP CONTROLS WITH PLUMBING CONTRACTOR. 000�css B-9,11 CONFIRM PUMP HE AND VOLTAGE WITH SUPPLIER. O TONAL71 °oa000000 -23 A-14 A 8 O A-11,13,15 4. COORDINATE FINAL SPECIFICATION WITH KITCHEN DESIGN SUBMITTAL SPEC SHEET. 3/4,.G,3#6,H10G A-16 A-2 4 5. INDOOR UNIT POWERED BY OUTDOOR HEAT PUMP UNIT. 6 rr A-17,19,21 1/2"C,3#10,//10G A-20 3 2 9 FCU-2 ENG��RING,INC ���A-22 FHP,120V - 75 A-24 D D O 16 A-23 7 5 m m cn A_31 5 o000° o a A-26 A-28 � � Y o ❑ HWCP-1 Q w a ERV-1-1 FHP,120V1P2 0 0 ¢ p 1/2HP,1/2HPV2P2W B-17 A 2 A-33,35,37 0 ' -13,15 COED - --- ELECTRICAL KITCHEN EQUIPMENT SCHEDULE ------WH-1 TAG p DESCRIPTION VOLTAGE/PH kW MAKE&MODEL 0.24KVA,120V1P2W A-29 1 WALK-IN COOLER/FREEZER 208V/3 - KOLPAK F O ' 1.1 EVAPORATOR COIL 120V/1 1.44 ROBOT COUPE CL50 ULTRA 1 04 0 00 L-LL- ED 1.4 EVAPORATOR COIL 120V/1 1.22 HOSHIZAKI KM-520MAJ w CV ---- IN El G 8 MULTICOOK OVEN 208V/3 13.9 ALTO-SHAAM VMC-H4H 0. 9 COMBI OVEN 208V/1 6.77 ALTO-SHAAM CTX4-10EVH / \ j o I O 16 REF SANDWICH TABLE 115V/1 0.747 TSSU-60-12-HC \y� > co ' mo 20 FOOD PROCESSOR 120V/1 0.84 ROBOT COUPE R2CLRDICE -" O §rn m pJ 23 20 OT FOOD MIXER 120V/1 0.39 HOBART HL200-1STD J _ m '0 O ui N 35 VENTLESS DISHWASHER 208V/3 2.62 CHAMPION DH-6000-VHR Q Q !3 z 50 GLASS DOOR MERCHANDISER 115V/1 0.839 GDM-49HC-TSLO1 4 J 0 5 7 — 55 HIGH SPEED OVEN 208V/1 6.5 UNOX XASW-03HS-EDDS _U ' 56 2 DOOR UC REFRIGERATOR 115V/1 0.345 HOSHIZAKI UR4 78B Z ICI Z_ 57 COFFEE BREWER 120V/1 1.37 BUNN 12950.0360 0 _t- �O//) 65 POINT OF SALES 120V/1 1,759 STRUCTURAL CONCEPTS C3Z3667 O V Z 68 ESPRESSO MACHINE 120V/1 1.7 CIMBALI M26 TE RE DT/2 F5 CD N /'1A w w Lu w 69 UC ICE MACHINE 115V/1 0.345 SCOTSMAN CU0415MA-1 Z 71 UC REFRIGERATOR 115V/1 0.253 TURBO AIR TUR-28SD-N-L w Z 72 ESPRESSO GRINDER 11OV/1 0.600 ROSITOBISANI F64E d w' ' 75 AMBIENT DISPLAY CASE 120V/1 0.048 STRUCTURAL CONCEPTS CG2830 DATE: 11/15/2023 76 REF GRAB&GO CASE 120V/1 1.05 STRUCTURAL CONCEPTS C033R-U 94 OPEN AIR REF MERCHANDISER 120V/1 1.2 STRUCTURAL CONCEPTS 83424 SHEET TITLE: POWER PLAN- POWER PLAN - MAN 1 MAIN SCALE: 1/4" = 1'-0" N SHEET N0 E3.00 COP—T 2023.RNEKON ENGINEEPoNC.INC KEENEAR F:\1131-003 JOST POKE IN SNOHOMISH,wA\DK\E3.W POKERNiN 04-28-2023 12:24 SHEET NOTES: 1. PER 2020 NEC 210.8(B): ALL 50 AMPS OR LESS SINGLE PHASE RECEPTACLES RATED 150V TO GROUND OR LESS&ALL 100 AMPS OR LESS,THREE PHASE RECEPTACLES RATED 150V TO GROUND OR LESS WITHIN KITCHEN,BATHROOM,ROOFTOP,OUTDOORS,SINKS, AND INDOOR WET LOCATIONS SHALL HAVE GFCI PROTECTION AT THE PANEL OR AT THE RECEPTACLE 2. PROVIDE CONDUIT,WIRING,CIRCUITS AND CONNECTIONS AS COORDINATED WITH SECURITY VENDOR FOR FULLY FUNCTIONING SECURITY AND ACCESS CONTROL SYSTEM.COORDINATE WITH SECURITY CONSTRUCTION DOCUMENTS TO IDENTIFY ALL CAMERA LOCATIONS,AT ALL DOORS CALLED OUT BY OWNER. N 3, AMENITY SPACES,OFFICES AND PUBLIC AREAS: ROUGH-INFOR 0 EQUIPMENT,OUTLETS AND APPLIANCES IN AMENITY SPACES BE COORDINATED WITH ARCHITECT.REFER TO ARCHITECTS DRAWINGS Z N AND ELEVATIONS. W O N P: W 4. CONTRACTOR TO COORDINATE DOOR CONTROLS AND CONNECTIONS Q_ EC WITH DOOR VENDOR.PROVIDE RACEWAY,CONDUCTORS,POWER K SUPPLY AND TERMINATIONS FOR A FULLY FUNCTIONING SYSTEM. :E U COORDINATE WITH SECURITY VENDOR FOR MONITORING AND w W O CONTROL AS NEEDED. CL 0 O 5. ELECTRICAL CONTRACTOR(EC)TO PROVIDE BOX/PULL BOX SO NUMBER OF BENDS IN CONDUIT DOES NOT EXX CEED CODE REQUIREMENT(360 MAX TOTAL).EC TO FIELD VERIFY LOCATION OF Q J-BOX/PULL BOX.COORDINATE WITH ARCHITECT WHERE ACCESS = PANEL IS REQUIRED. O FLAG NOTES: ® f Z (NOT EVERY FLAG IS USED ON EVERY SHEET) 1. SERVICE RECEPTACLES MUST BE WITHIN 25'OF HVAC EQUIPMENT. OOOpO ST 0000 CONTRACTOR RESPONSIBLE TO COORDINATE LOCATION WITH HVAC HQIC CONTRACTOR F MOUNT THE RECEPTACLES ON THE OF VA EQUIPMENT FRAMEWORK. yCA��OOO 2. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR - g 0 PRIOR TO INSTALLATION. p 3. COORDINATE PUMP ROUGH-IN,CONTROLLER LOCATION AND O ' o� 00O0 CONDUITS FOR PUMP CONTROLS WITH PLUMBING CONTRACTOR. O� �AL.. ($' CONFIRM PUMP HP AND VOLTAGE WITH SUPPLIER. `�O'�`/ 4. COORDINATE FINAL SPECIFICATION WITH KITCHEN DESIGN SUBMITTAL �aDo SPEC SHEET. 5. INDOOR UNIT POWERED BY OUTDOOR HEAT PUMP UNIT. ROBISON ENGINEERING,INC I WIWTHA ew'SJIILISI �vzos�ais<3 - REIPNOJECTNO CONTACT PETERROC—AID HP-1 4.83KVA,208V2P2W B-1,3 2 W ECI o 0 3 HP-2 Z Z > 3 � Y o U � 3.16KVA,208V2P2W a U) w a w T a 8-5,7 0 o U a 0 2 3 ELECTRICAL KITCHEN EQUIPMENT SCHEDULE TAG R DESCRIPTION VOLTAGE/PH kW MAKE&MODEL 1 WALK-IN COOLER/FREEZER 208V/3 - KOLPAK 1.1 EVAPORATOR COIL 120V/1 1.44 ROBOT COUPE CL50 ULTRA 1 1.4 EVAPORATOR COIL 120V/1 1.22 HOSHIZAKI KM-520MAJ w CV LL 00 8 MULTICOOK OVEN 208V/3 13.9 ALTO-SHAAM VMC-H4H p. 9 COMBI OVEN 208V/1 6.77 ALTO-SHAAM CTX4-10EVH U j o > w 16 REF SANDWICH TABLE 115V/1 0.747 TSSU-60-12-HC co 20 FOOD PROCESSOR 120V/1 0.84 ROBOT COUPE R2CLRDICE 05 _O W m 23 20 OT FOOD MIXER 120V/1 0.39 HOBART HL200-1STD mwo N 35 VENTLESS DISHWASHER 208V/3 2.62 CHAMPION DH-6000-VHR Q Q 3 z 50 GLASS DOOR MERCHANDISER 115V/1 0.839 GDM-49HC-TSLO1 J 2a 00 55 HIGH SPEED OVEN 208V/1 6.5 UNOX XASW-03HS-EDDS _U7 56 2 DOOR UC REFRIGERATOR 115V/1 0.345 HOSHIZAKI UR48B Z ICI Z_ 57 COFFEE BREWER 120V/1 1.37 1 BUNN 12950.0360 0 _t- �O//�� Lo 65 POINT OF SALES 120V/1 1,759 STRUCTURAL CONCEPTS C3Z3667 O V Z 68 ESPRESSO MACHINE 120V/1 1.7 CIMBALI M26 TE RE DT/2 0 CD N /'� w w w 69 UC ICE MACHINE 115V/1 0.345 SCOTSMAN CU0415MA-1 Z 71 UC REFRIGERATOR 115V/1 0.253 TURBO AIR TUR-28SD-N-L w 72 ESPRESSO GRINDER 110V/1 0.600 ROSITOBISANI F64E a a W / 75 AMBIENT DISPLAY CASE 120V/1 0.048 STRUCTURAL CONCEPTS CG2830 DATE: 11/15/2023 76 REF GRAB&GO CASE 120V/1 1.05 STRUCTURAL CONCEPTS C033R-U 94 OPEN AIR REF MERCHANDISER 1 120V/1 1 1.2 STRUCTURAL CONCEPTS 83424 SHEET TITLE: POWER PLAN- POWER PLAN - ROOF ROOF SCALE: 1/4" = 1'-0" N SHEET N0 3.01 CO-IIOHT 2023,ROBISON ENOINEEPoNO,INC BBENEAR F:\1131-003 JOST POKE IN SNOHOMISH,WA\DWO\E3.W POKRDNN 04-28-202312:24 COORDINATION AND ARC FLASH STUDIES: GROUNDING NOTES AND REQUIREMENTS: SHEET NOTES: (FOR E5.00) Panel ROOM VOLTS 208Y/120V 3P 4W AIC 22,000 Panel ROOM VOLTS 201 3P 4W AIC 2$000 MOUNTING FLUSH BUS AMPS 200 MAIN BKR MILD MOUNTING FLUSH BUS AMPS 200 MAIN BKR MLO IMMEDIATELY UPON SELECTION OF ACTUAL EQUIPMENT BEING PROVIDED THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE A. CONTRACTOR TO OBTAIN UTILITY APPROVAL OF ALL SERVICE A FED FROM XFMR NEUTRAL 100% LUGS STANDARD B FED FROM XFMR NEUTRAL 100% LUGS STANDARD FOR THE PROJECT,THE ELECTRICAL CONTRACTOR SHALL PERFORM AN GENERAL CONTRACTOR,POWER COMPANY,PHONE COMPANY, AND METERING EQUIPMENT PRIOR TO ORDERING. NOTE NOTE ARC FLASH ANALYSIS AND COORDINATION STUDY ON THE STANDBY INTERNET COMPANY, CABLE TV COMPANY, AND THE SATELLITE DISTRIBUTION BASED ON ACTUAL EQUIPMENT TO BE PROVIDED, TV COMPANY TO ENSURE REQUIRED GROUNDING IS INSTALLED B. DISTRIBUTION SYSTEM AS DESIGNED IS FULLY RATED. GKT CKT LOAD CKT CUT LOAD CKT CUT LOAD CKT CKT LOAD CONDUCTOR TYPES/SIZES/LENGTHS,ETC.COORDINATION SHALL BE FOR EACH SYSTEM. CONTRACTOR WILL BE RESPONSIBLE FOR ENGINEERING IF SERIES BKR KVA CIRCUIT DESCRIPTION BKR KVA CIRCUIT DESCRIPTION BKR KVA CIRCUIT DESCRIPTION BKR KVA CIRCUIT DESCRIPTION CONFIRMED BASED ON FAULT NUMBERS SHOWN ON THIS DRAWING. RATED SYSTEMS ARE SUBMITTED,THE SUBMITTED SYSTEM SHALL 1 20/3 1.73 WALK IN COOLER/FREEZER a 2 30/3 6.5 HIGH SPEED OVEN 1 40/2 4.83 HI a 2 20/1 0 SPARE STUDIES SUBMITTED SHALL BE STAMPED BY A PROFESSIONAL THIS SHALL BE DONE PRIOR TO AND DURING INSTALLATION OF MEET NEC 240.86(B)REQUIREMENTS FOR TESTED COMBINATIONS, 3 1 b 4 1 3 b 4 20/1 0 SPARE ELECTRICAL ENGINEER HOLDING A CURRENT LICENSE FROM THE STATE FOUNDATION RE-BAR AND CONTINUE DURING THE CONSTRUCTION AND SHALL NOT BE USED IF MOTOR CONTRIBUTION EXCEEDS 5 1 c 6 1 5 25/2 3.16 HP-2 c 6 20/1 0 SPARE OF WA. PHASES, TO ENSURE EACH SYSTEM HAS ITS REQUIRED LIMITS PER 240.86(C).NEC 110.22 MARKING REQUIREMENTS 7 20/1 1.44 EVAPORATOR COIL a 8 20/1 0.345 2 DR UC FRIDGE 7 1 a 8 20/1 0 SPARE PRELIMINARY ARC FLASH AND COORDINAPON STUDIES ARE TO BE GROUNDING INSTALLED FOR PROPER OPERATION OF THE SYSTEM. MUST BE MET. � 9 20/1 1.44 EVAPORATOR COIL b 10 20/1 1.37 COFFEE BREWER 9 15/2 0.729 FCU-1 b 10 20/1 0 SPARE SUBMITTED WITH THE SUBMITTALS FOR THE PROTECTIVE DEVICES, C. PROVIDE PERMANENT WARNING LABELS FOR ARC FLASH AND Z 11 50/3 13 MULTI COOK OVEN c 12 20/1 1.76 POS 11 1 c 12 20/1 0 SPARE PANELBOARDS,SWITCHBOARDS,AND OTHER ELECTRICAL EQPT. PPE REQUIREMENTS FOR THE SERVICE EQUIPMENT AND PANELS. o 13 1 a 14 20/1 0.253 UC ICE MACHINE 13 15/2 2.35 ERV-1-1 a 14 20/1 0 SPARE THE ELECTRICAL CONTRACTOR SHALL COORDINATE AND PROVIDE ZU VI b 16 20 1 1.7 ESPRESSO MACHINE 15 20 1 0 SPARE THE ELECTRICAL CONTRACTOR SHALL SUBMIT THE STAMPED AND WHAT IS REQUIRED TO DO THE FOLLOWING 15 : w / b 16 / SIGNED ARC FLASH AND COORDINATION STUDY TO THE AHJ AS N w 17 30/3 6.77 COMBI OVEN c 18 20/1 0.253 UC FRIDGE 17 20/1 0.1 HIc 18 20/1 0 SPARE REQUIRED. 1. FOOTING GROUND RE-BAR COMES UP IN THE ELECTRICAL 19 a 20 20/1 0.8 COFFEE GRINDER 19 20/1 0.18 RECEPTACLE a 20 20/1 0 SPARE OD ROOM AND THE RE-BAR IS SNUGLY SECURED TO THE U 21 b 22 20 1 1 0.6 COFFEE GRINDER 21 20 0 SPARE b 22 20 1 0 SPARE THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL . / / / PERMANENT LABELS INDICATING ARC FLASH HAZARD RISK CATEGORIES FOOTING RE-BAR PER OWNER DETAIL w w 23 20/1 0.84 REF SANDWICH TABLE c 24 20/1 1..048 PASTRY DISPLAY CASE 23 20/1 0 SPARE c 24 20/1 0 SPARE DI ALL DISTRIBUTION POINTS(SWITCHBOARDS.COMPLY OARDS, PA 7 2. THE MSB GROUNDING TIES TO THE FOOTING RE-BAR, d 25 20/1 0.39 FOOD PROCESSOR a 26 20/1 1.76 REF GRAB STAND 25 20/1 0 SPARE a 26 20/1 0 SPARE DISCONNECT SWITCHES,ETC). LABELS SHALL COMPLY WITH NFPA 70E. COUNTERPOISE,BUILDING STEEL, AND WATER PIPING. 27 20/1 0.39 FOOD MIXER b 28 20/1 1.78 POS 27 20/1 0 SPARE b 28 20/1 0 SPARE FLAG NOTES: (FOR E5.00) 29 20/1 0.24 WH-1 c 30 20/1 1.2 OPEN AIR MERCHANDISER 29 20/1 0 SPARE c 30 20/1 0 SPARE 3. THE GROUND WIRE FOR THE COUNTERPOISE SHALL BE 4 31 20/1 0.84 GLASS DOOR MERCHANDISER a 32 20/1 0 SPARE 31 20/1 0 SPARE a 32 20/1 0 ARE STRANDED, INSULATED WIRE IN CONDUIT UNTIL IT REACHES o 33 20/3 2.62 VENTLESS DISHWASHER b 34 20/1 0 SPARE 33 20/1 0 SPARE b 34 20/1 0 SPARE THE FIRST BAR OF THE COUNTERPOISE.BETWEEN THE 1. EXISTING ELECTRICAL EQUIPMENT. 35 1 c 36 20/1 0 SPARE 35 20/1 0 SPARE c 36 20/1 0 SPARE COUNTERPOISE BARS IT SHALL BE A STRANDED BARE COPPER WIRE. 37 1 a 38 20/1 0.332 LIGHTING 37 20/1 0 SPARE a 38 20/1 0 SPARE f Z 39 20/1 0 SPARE b 40 20/1 0.238 UGHTING 39 20/1 0 SPARE b 40 20/1 0 SPARE 41 20/1 0 SPARE c 42 20/1 1.26 RECEPTACLE 41 20/1 0 SPARE c 42 20/1 0 SPARE CON �OOOppOOO CALL CONN CALL CONN CALL CONN CALL EVA GENERAL FEEDER SCHEDULE KVA KVA KVA KVA KVA KVA KVA KVA V OFVy4SN LIGHTING 0.569 0.712 (125%) MOTORS 0.24 0.24 (100%) LARGEST RECEPTACLES 0.18 0.18 (50%>10) LARGEST RECEPTACLES 4.78 4.78 (50%>10) MOTOR 4.83 1.21 (25%) HEATING 2.35 2.35 (100%) FEEDER CONDUIT AND FEEDER FEEDING THESE DEVICES m p H'I 0.24 0.06 (25%) KITCHEN MOTOR MOTORS 8.82 8.82 (100%) COOLING 2.35 0 (100 p EQUIPMENT 43.7 28.4 (65%) 200 2-1/2"C,3#250kcmil AL,#250kcmil AL N,#2 AL G A, B OS IS p TOTAL LOAD 12.6 TOTAL LOAD 34.2 BALANCED 3-PHASE ADD (2)2-1/2"C,3#25Okil AL,#250kil AL N,#1/0 XFMR \C' 10 ' BALANCED 3-PHASE P A QgSp 3 CNAL LOAD 95 A X8 A A cm cm L G �O �Fj'23 PHASE A 95.7% PHASE B 137 SIZING METHOD: COPPER,60'C#12 THROUGH#1,75 ODOOD'C 1/0 AND ABOVE 1l� PHASE B 108E PHASE C 54% PHASE C 95.7% FEEDER SCHEDULE NOTES: CONDUIT FILL: * FOR CONDUIT SIZES 1-1/2"AND BELOW,FILL IS BASED ON EMT. - * FOR CONDUIT SIZES 2"AND ABOVE,FILL IS BASED ON SCHEDULE 40 PVC. a,s IN LOCATIONS APPROVED FOR THE PURPOSE, CONTRACTOR MAY USE MC CABLE. IN LOCATIONS APPROVED FOR THE PURPOSE CONTRACTOR MAY USE OTHER CONDUIT TYPES,INCLUDING RMC, FMC AND LFMC. CONTRACTOR REQUIRED TO ENSURE CONDUIT FILL DOES NOT EXCEED 40%. R0131SON CONTRACTOR RESPONSIBLE TO ENSURE TERMINATION/LUG CAPACITY FOR ALL SCHEDULED FEEDERS. ENGINEERING,INC XHHW/THHN/THWN SHALL BE USED FOR INSULATION OF THE CONDUCTOR. mi_HAVEw.SUrE3C2 LYWO NOD,MW36 .S.33E3T¢ RCONTACT ECEN0.:9fi2020 m ED V1 OL D_ x Of 0 0 o w w 0 3 Y o U C a n w a s w x a LEVEL 02 M UJ N A LL cp 2208Y/0 0001 i0V 3P 4W 2 20 0001 i0V 3P 4W 01 N 0 �x Fw 0.6 O 3 M XFMR EXISTING 208Y/120V 3P 4W 1 ¢3 m BUILDING W .� oo1 DISTRIBUTION Q Q n: El E GEAR zo IL OIL L) Z Zz 0 0 0 ICI � m W LEVEL 01 LJJ N W Ll0 W DATE: 11/15/2023 SHEET TITLE: ONE-LINE DIAGRAM SHEET NO. E5.00 CO-TIGHT 2022,RWISON ENawEEPoNa,INC MSIEINHE C.\TRESOURCE`WER\STBNKE ILAt4NS TEMPLATES\APARIMENT 30%42\E500 ONE MNI IO-0Y2022 10:41 GENERAL NOTES ABBREVIATIONS SYMBOLS ACU AIR CONDITIONING UNIT EQUIPMENT DUCTWORK AFF ABOVE FINISHED FLOOR EF-1 TYPICAL EQUIPMENT DESIGNATION DUCT(1ST FIGURE=SIDE SHOWN,2ND GENERAL NOTES-MECHANICAL 4. APPROVALS:MECHANICAL AND PLUMBING EQUIPMENT SHALL BE AHJ AUTHORITY HAVING (EXHAUST FAN SHOWN) 18z12 FIGURE=SIDE NOT SHOWN) APPROVED FOR INSTALLATION IN THE PROJECT LOCATION AND SHALL 4. ROUND TEES AND LATERALS:CONICAL TEE PER SMACNA HVAC FIG 3-5;DO JURISDICTION 1. REFERENCE TO RELATED WORK:"REF"INDICATIONS DENOTE WORK HAVE ALL CERTIFICATIONS AND RATINGS TO MEET ALL ENERGY, NOT USE STRAIGHT TEE;DO NOT USE CONICAL SADDLE TAP FOR EXPOSED AHU AIR HANDLING UNIT UP DOWN COVERED ELSEWHERE(ARCHITECTURAL,STRUCTURAL,CIVIL, POLLUTION,ENVIRONMENTAL,SEISMIC,ETC.CODES AND REGULATIONS. DUCTWORK IN FINISHED SPACES.90-DEGREE TEE WITH OVAL TO ROUND BDD BACKDRAFT DAMPER DSD DUCT SMOKE DETECTOR ® DUCT SECTION,POSITIVE PRESSURE ELECTRICAL,LANDSCAPE,OR KITCHEN),OR ITEM BASED ON A SPECIFIC THE CONTRACTOR SHALL COORDINATE WITH HIS MANUFACTURE TAP,LATERAL,AND 45-DEGREE RECTANGULAR LEAD-IN PER SMACNA HVAC BHP BRAKE HORSEPOWER MANUFACTURER'S DIMENSIONS(VERIFY). SUPPLIERS AND SHALL INCLUDE ALL COSTS REQUIRED TO MEET THESE FIG 3-4. BTUH BRITISH THERMAL UNIT ROOM THERMOSTAT OR UP DOWN REQUIREMENTS IN HIS BID. PER HOUR TEMPERATURE TRANSMITTER DUCT SECTION,NEGATIVE PRESSURE 2. ELECTRICAL CHARACTERISTICS:REFER TO ELECTRICAL DRAWINGS FOR 5. RECTANGULAR ELBOWS AND OFFSETS:FULL RADIUS WHERE SPACE C COMMON ELECTRICAL CHARACTERISTICS(VOLTAGES,ETC.OF MECHANICAL 5. FIRE PROTECTION:CONTRACTOR SHALL PROVIDE A FULLY DESIGNED FIRE PERMITS,R/W=1.5;OTHERWISE USE SQUARE CORNER ELBOW WITH CAP CAPACITY y UP DOWN N EQUIPMENT,UNLESS OTHERWISE INDICATED. PROTECTION SPRINKLER SYSTEM IN COMPLIANCE WITH NFPA AND LOCAL TURNING VANES. CC COOLING COIL O ROOM HUMIDISTAT OR HUMIDITY 1 I\ � ROUND DUCT SECTION O CODES.PROVIDE DESIGN,PERMITS,MATERIALS,INSTALLATION,TESTING CD CEILING DIFFUSER TRANSMITTER ITIY z N 3. CODES:COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE AND ALL OTHER FOR A FULLY OPERATIONAL SYSTEM.LOCATION OF ALL 6. RECTANGULAR DIVIDED FLOW FITTINGS:USE GENERALLY,EXCEPT CFM CUBIC FEET PER MINUTE ® CARBON MONOXIDE SENSOR UP UP UP DUCT PENETRATION THRU FLOOR OR o w PER THE APPLICABLE BUILDING,MECHANICAL,ENERGY,PLUMBING,FIRE, PIPING TO BE COORDINATED WITH OTHER TRADES. BRANCHES TO TERMINALS;SMACNA HVAC FIG 2-5,TYPES 1,2,4A,AND 4B. CLG CEILING,COOLING ® 4 m ROOF tr w AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL AHJ. DO NOT USE TYPE 3. CO CLEANOUT SMOKE DETECTOR v 6. FIREPLACES:COORDINATE WITH THE GENERAL CONTRACTOR TO COMB COMBUSTION TERMINALS N 4. PREPARE AND SUBMIT FOR REVIEW A SHOP DRAWING BASED ON FINAL DETERMINE GAS FIREPLACE FLUE AND COMBUSTION AIR DUCTWORK 7. TURNING VANES:H.E.P.MANUFACTURER OR APPROVED HIGH EFFICIENCY CONT CONTINUE,CONTROL VOLUME DAMPER o STRUCTURAL SHOP DRAWINGS FOR LOCATING AND ROUTING ALL REQUIREMENTS PRIOR TO BIDDING. PROFILE AIRFOIL TYPE FOR RECTANGULAR SQUARE THROAT ELBOWS. COP COEFFICIENT OF CD-12z12 OR CD-1 rDIFFUSER/GRILLE TYPE,AND NUMBER DUCTWORK,DAMPERS,EQUIPMENT,PIPING,ETC. ACOUSTICAL TYPE FOR RETURN AIR MITERED ELBOWS. PERFORMANCE 400 400 -DESIGN CFM(WHERE APPLICABLE) TFSD FIREISMOKE DAMPER(--<I=HORIZ w A. COORDINATE FLOOR AND BEAM PENETRATIONS WITH STRUCTURAL. PIPING NOTES CWS CHILLED/CONDENSER WATER FSD DUCT,-<>=VERT DUCT),2-HR RATED, Q CEILING DIFFUSER(FLOW ARROWS B. COORDINATE FINAL LOCATION AND ROUTING WITH CEILING LIGHTS 8. TAKEOFFS TO OPENINGS:CONICAL TYPE WITH VOLUME DAMPER FOR o WALLS,FIRE SPRINKLER PIPING,AND OTHER TRADES WORK. 1. DISASSEMBLY PROVISIONS:PROVIDE UNIONS OR FLANGES AT PIPING ROUND DUCT BRANCHES PER SMACNA HVAC FIG 2-6,MINIMUM INLET CWR CHILLED/CONDENSER WATER SHOWN FOR NON SYMMETRICAL UON AIRFLOW) T FD FIRE DAMPER(-<=HORIZ DUCT, C. INCLUDE ADDITIONAL OFFSETS,ELBOWS,ROUTING,EQUIVALENT DUCT CONNECTIONS TO EQUIPMENT,COILS,TRAPS,CONTROL VALVES,AND DIAMETER 2 INCHES LARGER THAN DUCT SIZE.45 DEGREE ENTRY FITTING RETURN I� FD VERT DUCT),2-HR RATED,ION SIZING EXCHANGE,RELOCATING,ETC.AS REQUIRED FOR A COMPLETE OTHER COMPONENTS TO ALLOW DISASSEMBLY FOR MAINTENANCE. FOR RECTANGULAR DUCT BRANCHES PER SMACNA HVAC FIG 2-6. D DIAMETER VJ o OPERATING MECHANICAL SYSTEM. IDS DRY BULB,DECIBEL �J- CEILING RETURN/EXHAUST GRILLE z D. PROVIDE SHOP DRAWINGS AT NO ADDITIONAL COST TO THE OWNER. 2. REDUCERS:PROVIDE AS REQUIRED FROM LINE PIPE SIZE TO EQUIPMENT, 9. FLEXIBLE CONNECTIONS:PROVIDE AT EACH DUCT CONNECTION TO FANS, DIM DIMENSION I LINEAR DIFFUSER,CEILING OR WALL 90°ELBOW,RID OR R/W=1.5 5. MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE EXACT TRAP,COIL,AND CONTROL VALVE CONNECTION SIZES. PACUNITS,GED FAN COIL UNITS,AND SIMILAR EQUIPMENC EQUIPMENT,EXTERNALLY T.EXCEPTION:EQUIPMENT TED AIR HANDLING pN CH DISCHARGE O MOUNTED(FLOW ARROWS SHOWN OOppo0 AC0000 LOCATION OF ALL MECHANICAL EQUIPMENT WITHIN THE STRUCTURE. 3. OFFSETS:PROVIDE FOR BRANCH LINES TO EQUIPMENT. IN CORRIDOR CEILING SPACES WHERE FIRE RATING IS REQUIRED. EA EXHAUST AIR FOR NON SYMMETRICAL AIRFLOW) pp EAT ENTERING AIR TEMPERATURE SQUARE CORNER ELBOW WITH OD WALL SUPPLY GRILLE(SG) 6. ACCESS DOORS:COORDINATE WITH ARCHITECT AND LOCATE ALL ACCESS 4. DIELECTRIC UNIONS:PROVIDE AT CONNECTIONS OF DISSIMILAR PIPE. HVAC NOTES EER ENERGY EFFICIENCY RATIO TURNING VANES 'yam o DOORS ON P ACCESS IN FIRE RATED STRUCTURE BEGINNING SHALL BE F RE RATED.OF IVERIFY 5. REFRIGERANT PIPING:PROVIDE SIZING R INSTALLATION IN STRICT 1. ATTACHMENTS:AIR DISTRIBUTION OUTLETS AND LOUVERS SHALL HAVE EFF EFFICON. EF IENCY N E CY WALL RETURN/EXHAUST GRILLE(FIG, ACCESS DOOR LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. ALL REQUIRED ACCESSORIES AND ATTACHMENTS FOR A COMPLETE EG EXHAUST GRILLE �� EG) 90°TAKE-OFF OR TEE O R ins �000 BIDDING. CONNECTION TO THE SPECIFIC TYPE OF STRUCTURE THAT THEY ARE ELEC ELECTRIC pOs9 TRANSFER GRILLE(TG),DU 6. CONDENSATE DRAIN:PROVIDE A P-TRAP FOR EACH HVAC UNIT BEING ATTACHED TO.THIS INCLUDES,BUT IS NOT LIMITED TO,EXTERIOR ESP EXTERNAL STATIC PRESSURE CT �000 CID 7. RATED PENETRATION:DUCT PENETRATIONS THROUGH RATED CONDENSATE PAN WITH PLUG TEES FOR CLEANING.CONDENSATE DRAINS BRICKS,GWB WALLS,GWB CEILING,ETC. EXH EXHAUST �� 50 CONNECTED,WALL MOUNTED W/ 90°CONICAL TAKE-OFF 15 2 ENCLOSURES SHALL BE FIRE/SMOKE DAMPERED PER THE LATEST EDITION SHALL BE DISCHARGED TO AN INDIRECT WASTE OR OUTSIDE. OPTIONAL CFM SHOWN 11' EXT EXTERIOR,EXTERNAL TRANSFER GRILLE,CEILING MOUNTED OF THE UNDERWRITERS LABORATORIES(UL)FIRE RESISTANCE WITH 2. DUCTWORK:DUCTWORK SHALL BE SMOOTH SHEET METAL(CLASS-1). F FAHRENHEIT i i� � WITH FULL-SIZED LINED DUCT 45°LATERAL TAKE-OFF HOURLY RATINGS FOR THROUGH-PENETRATION FIRE STOPS SYSTEM INSULATION/LINING NOTES DUCTWORK THROUGH FIRE RATED STRUCTURE AND FLOOR SHALL BE MIN. FCU FAN COIL UNIT CONNECTION VOLUME#2,OR SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE 26 GA.STEEL.MAXIMUM LENGTH OF FLEXIBLE DUCTS SHALL BE 5'-0", FLR FLOOR MANUFACTURER'S UL LISTINGS(3M OR EQUIVALENT).DETERMINE 1. ENERGY CODE:AS A MINIMUM,COMPLY WITH THICKNESSES AND TYPES UNLESS OTHERWISE NOTED ON DRAWINGS.DUCTWORK SIZES SHOWN FPM FEET PER MINUTE PIPING TRANSITION OR REDUCER(FOT=FLAT ' REQUIREMENTS WITH GENERAL CONTRACTOR PRIOR TO BID. LISTED IN ENERGY CODE ENFORCED BY AHJ. ARE INSIDE CLEAR DIMENSIONS. FPS FEET PER SECOND CD CONDENSATE DRAINAGE ON TOP,FOB=FLAT ON BOTTOM) ,l FSD FIRE/SMOKE DAMPER G NATURAL GAS-STD.PRESSURE 8. EXHAUST OUTLETS:SOURCE-SPECIFIC FANS SHALL BE VENTED TO 2. EXTENT OF INTERNAL DUCT LINING: 3. VOLUME DAMPERS:PROVIDE AN ACCESSIBLE MANUAL VOLUME DAMPER G GAS WYE FITTING O I ON OUTDOORS WITH A MINIMUM T CLEARANCE BETWEEN VENT OUTLETS AND A. GRILLE AND DIFFUSER BOXES AND BOOTS. FOR EACH SUPPLY,RETURN,OSA,AND EXHAUST OPENING,LOCATED AS GAL GALLONS MPG NATURAL GAS-MEDIUM PRESSURE BUILDING OPENINGS,AND 10'MINIMUM BETWEEN VENT OUTLETS AND B. TRANSFER DUCTS. FAR UPSTREAM AS POSSIBLE FROM THE OPENING.PROVIDE A MANUAL GPM GALLONS PER MINUTE ] PIPE CAP ENGINEERING,INC MECHANICAL AIR INTAKES. C. THE FIRST 10 FEET OF SUPPLY AND RETURN DUCTWORK FROM THE VOLUME DAMPER FOR BRANCH MAINS SERVING MORE THAN ONE GRID GRILLES,REGISTERS, 90°RECTANGULAR TAKE-OFF WITH 45° aai aorH nvew,swrs3c� AIR HANDLER. OPENING.VOLUME DAMPERS IN NON-ACCESSIBLE CEILINGS SHALL HAVE A DIFFUSERS PIPE PLUG LYMfW00 EWAS3l 9. ROOF PENETRATIONS:SEE ARCHITECTURAL DRAWINGS FOR ROOF CAP, CONTROL ARM EXTENDED TO AN ACCESSIBLE LOCATION. GWB GYPSUM WALLBOARD TAPER 20636b33E3m ROOF CURB,ROOF DRAIN,AND VTR DETAILS. 3. EXTENT OF EXTERNAL DUCT INSULATION: HD HEAD UNION on ncac�eacrsrea A. SUPPLY AND RETURN AIR IN UNCONDITIONED SPACES,MECHANICAL 4. SEISMIC:PROVIDE SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT, HORIZ HORIZONTAL FLANGE JiF 10. EXPOSED PIPING:PROVIDE CHROME PLATING FOR EXPOSED PIPING IN ROOMS,ELECTRICAL ROOMS,AND EQUIPMENT ROOMS NOT SPECIFIED PIPING,AND DUCTWORK PER SMACNA AND LOCAL REGULATIONS. HP HORSEPOWER i I IfF 90°DIVERGING RECTANGULAR TEE, FINISHED ROOMS. TO BE INTERNALLY LINED. HPU HEAT PUMP UNIT ���� GATE VALVE OR BALL VALVE EITHER RADIUS OR TURNING VANES B. SUPPLY AIR ABOVE CEILINGS OR EXPOSED NOT SPECIFIED TO BE 5. FILTER CLEARANCE:PROVIDE ADEQUATE CLEARANCE FOR CHANGING AIR HRU HEAT RECOVERY UNIT r�I� BALL VALVE 11. PENETRATIONS:PROVIDE ESCUTCHEON PLATES FOR EXPOSED PIPING INTERNALLY LINED. FILTERS. HVAC HEATING,VENTILATING, ^lam PRESSURE REDUCING VALVE(PRV) PENETRATIONS AND SHEET METAL FLASHING FOR EXPOSED DUCTWORK C. OUTDOOR AIR INTAKE. AND AIR CONDITIONING PARALLEL FLOW BRANCH PENETRATIONS. 6. DUCTWORK AND PIPING OUTSIDE OF MECHANICAL ROOMS SHALL BE HVU HEATING&VENTILATION i BREAK IN PIPING OR DUCTWORK CONNECTION,EITHER RADIUS OR a a a 4. MISCELLANEOUS DUCT FITTINGS(CONICAL TAKEOFFS,ETC.):WRAP WITH CONCEALED,COORDINATE WITH THE GENERAL CONTRACTOR TO FUR-OUT UNIT RL RAIN LEADER(RL) TURNING VANES o 0 12. SHAFT AND PLENUM CONNECTIONS:SEAL CONNECTIONS TO AIR SHAFTS INSULATION FOR CONDENSATION CONTROL. AS REQUIRED. HWR HOT WATER RETURN w o AIRTIGHT.PROVIDE AIRTIGHT SEAL AROUND PENETRATIONS IN AIR HWS HOT WATER SUPPLY OL OVERFLOW RAIN LEADER(OL) FLEXIBLE DUCT z z Y o PLENUMS. PLAN NOTES 7. FIRE RATINGS:RATED FLOOR/CEILING JOINT SPACES HAVING DUCTWORK HX HEAT EXCHANGER CHECK VALVE O ROUND DUCT INDICATOR a N w a INSIDE THEM SHALL BE FIRE/SMOKE PROTECTED TO MAINTAIN THE 1-HOUR ID INDIRECT DRAIN,INSIDE � w T a O Q 13. LIGHT FIXTURE CLEARANCE:COORDINATE LOCATIONS OF MECHANICAL 1. DUCTWORK SHALL BE METALLIC DUCTWORK FLOOR/CEILING RATING PER LOCAL JURISDICTIONS.EXHAUST DUCTWORK DIAMETER U WORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES FOR REMOVAL PENETRATING THE 1-HOUR ROOF/CEILING OR FLOOR/CEILING ASSEMBLY IN INCH AND REPLACEMENT. 2. TEST AND BALANCE WORK SHALL BE PERFORMED BY AN INDEPENDENT SHALL HAVE ACCESSIBLE CEILING FIRE DAMPERS.ALTERNATIVELY,THE KW KILOWATT CONTRACTOR SUBSTITUTIONS & REVISION S TEST AND BALANCE AGENCY.PROVIDE(3)COPIES OF TEST AND BALANCE EXHAUST DUCTWORK SHALL BE ROUTED INSIDE A RATED SHAFT TO L LONG,LENGTH 14. MOTORS:COMPLY WITH ENERGY CODE ENFORCED BY AHJ FOR MINIMUM REPORT TO OWNER. PROTECT THE CEILING/ROOF RATING PER THE LOCAL JURISDICTIONS. LB POUND EFFICIENCIES UNDER FULL LOAD. MBH THOUSAND BTU PER HOUR 3. COORDINATE DUCTWORK WITH MISCELLANEOUS OBSTRUCTIONS IN 8. FIRESTOP:PIPE,DUCT AND CONDUIT PENETRATIONS THROUGH RATED MECH MECHANICAL CONTRACTOR SUBSTITUTIONS&REVISIONS:PLEASE SUBMIT PROPOSALS FOR SUBSTITUTIONS OR REVISIONS 15. ACCESS CLEARANCES FOR MAINTENANCE AND REPLACEMENT:VERIFY CEILING SPACE. ASSEMBLIES SHALL BE FIRE AND SMOKE STOPPED PER CODE. MCA MIN.CIRCUIT AMPACITY FOR REVIEW AND APPROVAL PRIOR TO ORDERING MATERIAL OR DOING WORK.FOR EQUIPMENT THAT IS PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS MOCP MAX.OVER CURRENT SCHEDULED BY MANUFACTURER'S NAME AND CATALOG DESIGNATIONS,THE MANUFACTURER'S PUBLISHED CLEARANCES CAN BE MET.COORDINATE LOCATIONS OF MECHANICAL 4. RESTROOM EXHAUST SHALL BE A MINIMUM OF 10'FROM ANY MECHANICAL 9. DUCTWORK:DUCTWORK SHALL BE SMOOTH SHEET METAL(CLASS-1). PROTECTION DATA AND/OR SPECIFICATION FOR THAT ITEM ARE CONSIDERED PART OF SPECIFICATION.ENGINEERING COSTS WORK AND WORK OF OTHER TRADES TO PROVIDE ACCESS CLEARANCES OUTSIDE AIR INTAKES. DUCTWORK THROUGH FIRE RATED STRUCTURE AND FLOOR SHALL BE MIN. MTD MOUNTED FOR REVISING MEP PLANS SHALL BE ADDRESSED IN THE COST ANALYSIS OF THE SUBSTITUTION FOR SERVICE AND MAINTENANCE. 26 GA.STEEL.MAXIMUM LENGTH OF FLEXIBLE DUCTS SHALL BE 5'4- OSA OUTDOOR AIR PROPOSAL.CONTRACTOR TO COORDINATE WITH ENGINEER AND DETERMINE ASSOCIATED DESIGN AND 5. ROUTE DUCTWORK UNDERNEATH JOISTS UON. UNLESS OTHERWISE NOTED ON DRAWINGS.DUCTWORK SIZES SHOWN OBD OPPOSED BLADE DAMPER PERMITTING COSTS.CONTRACTOR SHALL BE RESPONSIBLE FOR OTHER COSTS ASSOCIATED WITH COORDINATION REQUIREMENTS ARE INSIDE CLEAR DIMENSIONS. OD OUTSIDE DIMENSION OR DIAMETER UNFORESEEN ISSUES RESULTING FROM SUBSTITUTIONS OR REVISIONS. 6. TRANSITION DUCT UNDER BEAMS AND DUCTS.FIELD VERIFY AVAILABLE OPNG OPENING M 1. PIPING:COORDINATE WITH STRUCTURAL FOR EXACT LOCATION OF ALL CEILING CAVITY DIMENSIONS. 10. VOLUME DAMPERS:PROVIDE AN ACCESSIBLE MANUAL VOLUME DAMPER P PUMP 04 STRUCTURAL FRAMING AND FOOTINGS AND FINALIZE THE EXACT ROUTING FOR EACH SUPPLY,RETURN,OSA AND EXHAUST OPENING,LOCATED AS PD PRESSURE DROP,PUMPED DRAIN w CV OF ALL PIPES WITH STRUCTURAL AND AT THE SITE PRIOR AND DURING THE 7. COORDINATE MOUNTING HEIGHT OF DIFFUSERS WITH ARCHITECTURAL FAR UPSTREAM AS POSSIBLE FROM THE OPENING.PROVIDE A MANUAL POC POINT OF CONNECTION U- 00 CONSTRUCTION. PLANS. VOLUME DAMPER FOR BRANCH MAINS SERVING MORE THAN ONE PRV PRESSURE REDUCING VALVE 01 OPENING.VOLUME DAMPERS IN NON-ACCESSIBLE CEILING SHALL HAVE A PSIG POUNDS PER SQUARE N 2. DUCTWORK:LOCATE AND COORDINATE THE EXACT LOCATION OF SHEET METAL NOTES CONTROL ARM EXTENDED TO AN ACCESSIBLE LOCATION.PROVIDE DRAWINGS ARE DIAGRAMMATIC,SHOWING THE GENERAL LOCATION,TYPE,LAYOUT,AND EQUIPMENT REQUIRED.THE Q o RA IN GAUGE AIR DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENT.REFER TO ARCHITECTURAL DRAWINGS FOR > m DUCTWORK WITH STRUCTURAL PLANS AND WITH THE GENERAL "YOUNG"REGULATOR OR EQUAL.EXACT LOCATION OF CONTROL DEVICES > w DIMENSIONS.REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND CONTRACTOR PRIOR TO INSTALLATION OF ANY STRUCTURE OR 1. REFERENCE:SMACNA HVAC DUCT CONSTRUCTION STANDARDS,METAL VISIBLE IN FINISHED SPACES SHALL BE COORDINATED WITH THE RD ROOF DRAIN INSTALLATION REQUIREMENTS.PROVIDE DUCTWORK NECESSARY FOR A COMPLETE SYSTEM.,CONNECTIONS,ACCESSORIES,OFFSETS,AND MATERIALS �x EQUIPMENT.COORDINATE WITH FRAMING CONTRACTOR TO ASSURE JOIST AND FLEXIBLE,CURRENT EDITION. ARCHITECT. REF REFERENCE W Nod' SPACES LINE UP WHEN DUCTWORK MUST PASS THROUGH DIFFERENT RF RELIEF FAN O 3 m JOIST SPACES. 2. CLEARANCE:COORDINATE DUCTWORK WITH MISCELLANEOUS 11. CORRIDOR THERMOSTAT:PROVIDE TAMPERPROOF THERMOSTATS IN RG RETURN GRILLE a 3 OBSTRUCTIONS IN CEILING SPACE. CORRIDORS.DO NOT PROVIDE PLASTIC GUARDS TO MAKE THE RPM REVOLUTIONS PER MINUTE 3. ADJUSTMENTS:ALL EQUIPMENT,MOTORS,FANS GAS BURNERS,IGNITION THERMOSTATS TAMPERPROOF.PROVIDE BLANK SECURABLE SA SUPPLY AIR O DEVICES,DRIVES,ETC.SHALL BE ADJUSTED AND BALANCED TO OPERATE 3. ROUND ELBOWS AND OFFSETS:FULL RADIUS(RID=1.5),5-PIECE THERMOSTAT COVERS. SCH SCHEDULE 04 CJ AT SPECIFIED RATINGS AS REQUIRED FOR THIS PROJECT SITE AND SEGMENTED OR STAMPED.REFER TO SMACNA HVAC FIG 2-7,3-3.DO NOT SF SUPPLY FAN,SQUARE FOOT Q Q o z z ACCOUNTING FOR ELEVATION ABOVE SEA LEVEL. USE ANGLED OFFSET(TYPE 1).MITERED OFFSET(TYPE 2)MAY BE USED UP SENS SENSIBLE D RAW I N G INDEX rn z a TO 30 DEGREE OFFSET ANGLE. SG SUPPLY GRILLE VICINITY MAP SMACNASHEET METAL AND AIR U CONDITIONING CONTRACTORS INCLUDED IN SET Z Z Z NATIONAL ASSOCIATION SO SCREENED OPENING O O SP STATIC PRESSURE �' SS STAINLESS STEEL, O SANITARY SEWER Z 34 SQ SQUARE H M Q 0 '^ TG TRANSFER GRILLE 0 L0M TYP TYPICAL W CAI �i1 W UH UNIT HEATER O Z UON UNLESS OTHERWISE NOTED w V VENT ' VENT VENTILATION,VENTILATOR W R VENT THRU ROOF WASTE,WATT,WIDE DWG DESCRIPTION a W •^`K WB WET BULB(TEMPERATURE) M0.00 LEGEND,GENERAL NOTES&DRAWING INDEX X M0.01 PROJECT NOTES,TABLES&CALCULATIONS X DATE: 11/15/2023 M0.02 MECHANICAL SCHEDULES X M2.01 LEVEL 1 HVAC FLOOR PLAN X SHEET TITLE: M2.02 LEVELS 2-4 TYPICAL HVAC FLOOR PLAN X COVER SHEET, M2.05 HVAC ROOF PLAN X GENERAL NOTES 8. APPLICABLE CODES M4.00 MECHANICAL DETAILS X DRAWING INDEX X THESE DRAWINGS ARE BASED ON THE FOLLOWING CODES: PROJECT INFORMATION M8.00 HVAC LOAD CALCULATIONS -2018 WASHINGTON STATE BUILDING CODE PARCEL NUMBERS: -2018 WASHINGTON STATE MECHANICAL CODE 00847300001 (SOUTH WING) SHEET NO -2018 WASHINGTON STATE FUEL GAS CODE 00847300001200 00(NORTH WING,OUTSIDE SCOPE OF WORK) O•OO -2018 WASHINGTON STATE ENERGY CODE VENTILATION CALCULATIONS 2018 WSMC-TABLE 403.3.1.1 AREA,SF ACTUAL ZONE AIR OSACFM OSACFM EXH CFM EXH CFM ROOM MECHANICALUNIT(S) ROOM CATEGORY DEFAULT OSACFM OSACFM OSACFM EXH CFM DISTRIBUTION (4) OCCUPANTS DEFAULT PEOPLE PER OSACFM/ OSACFM EXH CFM (WSMC (WSMC (WSMC (WSMC EFFECTIVENESS REQUIRED PROVIDED REQUIRED PROVIDED 0 OCCUPANTS 1,000 SF PERSON /SF /SF PERSON) AREA) TOTAL) TOTAL) o z VI KITCHEN 455 KITCHEN(COOKING) 10 10 20 7.5 0.12 0.7 75 55 130 319 0.8 163 175 399 600 U > r= w DRY STORAGE 52 JANITOR,TRASH,RECYCLING 0 0 0 0 0 1 0 0 0 52 0.8 0 0 65 100 MEN'S RR 52 TOILET ROOM(PUBLIC) 0 0 0 0 0 50 CFM 0 0 0 50 0.8 0 0 63 100 w WOMEN'S RR 52 TOILET ROOM(PUBLIC) 0 0 0 0 0 50 CFM 0 0 0 50 0.8 0 0 63 100 01 DINING ERV-1(900 CFM) 1,160 DINING ROOM 1 43 1 82 70 1 7.5 1 0.18 0 323 209 532 0 0.8 1 665 725 1 0 0 w CORRIDOR A 10/17/2023 TOTAL: 828 900 590 900 1 a 0 OTES: (1)VENTILATION RATES CALCULATED PER TABLE 403.3.1.1 AND ZONE AIR DISTRIBUTION EFFECTIVENESS FROM TABLE 403.3.1.1.1.2 IN THE 2018 WSMC. o z Oppp❑❑❑o0 O D Jq C,,O ❑oO��Ne oFvmvsy�ti:�o 00a O R ms �DO � SS/ONAL�00000 oaaCE3 ,23 11,15 n R0131SON ENGINEERING,INC I-AVEw.Swl E 2 LYNWOOWA930 O36 R0636b3 0 962 R EC�N 0.:9fi2020 NTACT 0 K U U (n a a a 0 0 o w 'w > 3 Y o U � a n w a co LU N IL 000 Q o. o C) REFRIGERANT PIPE INSULATION SCHEDULE(1)(2)(3)(4) 0,5 0 3A. _ a WSEC TABLE C403.10.3 OPERATING a 3 M J C xp to TEMPERATURE INSULATION CONDUCTIVITY NOMINAL PIPE OR TUBE SIZE VAPOR Lu •� ~O 0 N SERVICE RANGE,"F RETARDER NOTES O w 6 CONDUCTIVITY RANGE, MEAN TEMP. 1"TO 1Y2" 4"TO 8"AND REQUIRED Q ^3 z () BTU`IN/HOUR`FT'`"F RATING,°F <1 <1Y2" TO<4" 8" LARGER o z a 2.5" 2.5" NOT USED 201-250 0.27-0.30 150 (5) (5) 2.5" 3.0" 3.0" YES (7)(8) () VRF MAIN HIGH PRESSURE PIPE TO BRANCH CONTROLLER, Z Zz VRF MAIN GAS/SUCTION LINE, 1.5" 1.5" O 2018 WSEC-C DUCT INSULATION SCHEDULE VRF BRANCH SUCTION LINE TO INDOOR UNIT(HOT GAS SUPPLY) 141-200 0.25-0.29 125 (5) (5) 2.0" 2.0" 2.0" YES (7)(8) 2:_ MINI-SPLIT GAS LINE(HOT GAS SUPPLY,HEATING MODE) (� O DUCT TYPE INSULATION TYPE MIN.R-VALUE � ��� Z SUPPLY&RETURN AIR DUCTS IN UNCONDITIONED SPACE MINERAL-WOOL BLANKET 6.0 VRF BRANCH LIQUID LINE TO INDOOR UNIT(LIQUID RETURN), Q M W w rx VRF MAIN LIQUID LINE 105-140 0.21-0.28 100 1.0" 1.0" 1.5" 1.5" 1.5" YES (7)(8) Fil SUPPLY&RETURN AIR DUCTS LOCATED OUTSIDE THE BUILDING MINERAL-WOOL BLANKET 8.0 MINI-SPLIT LIQUID LINE(LIQUID RETURN,HEATING MODE) w SUPPLY&RETURN AIR DUCTS LOCATED IN BUILDING ENVELOPE ASSEMBLY MINERAL-WOOL BLANKET 16.0 O 'Z SUPPLY WITH AIR TEMP<55"F OR>105"F WITHIN CONDITIONED SPACE MINERAL-WOOL BLANKET 3.3 NOT USED 40-60 0.21-0.27 75 0.5" 0.5" 1.0" 1.0" 1.0" YES (7)(8) U SUPPLY WITH AIR TEMP<55"F OR>105"F WITHIN CONDITIONED SPACE DIRECTLY SERVED BY DUCT MINERAL-WOOL BLANKET 0.0 VRF VRF MA I MAIN SUCTION LINE FROM BRANCH CONTROLLER, N GAS/SUCTION LINE, w SUPPLY DUCTS EXPOSED WITHIN CONDITIONED SPACE MINERAL-WOOL BLANKET 0.0 VRF BRANCH SUCTION LINE TO INDOOR UNIT(GAS RETURN) <40 0.20-0.26 75 0.5" 1.0" 1.0" 1.0" 1.5" YES (7)(8) a RETURN&EXHAUST WITHIN CONDITIONED SPACE,DOWNSTREAM OF AN ENERGY RECOVERY MEDIA AND UPSTREAM OF MINERAL-WOOL BLANKET 8.0 MINI-SPLIT GAS LINE(RETURN,COOLING MODE) AUTOMATIC SHUTOFF DAMPER MINI-SPLIT LIQUID LINE(SUPPLY,COOLING MODE) DATE: 11/15/2023 RELIEF&EXHAUST WITHIN CONDITIONED SPACE,DOWNSTREAM OF AUTOMATIC SHUTOFF DAMPER MINERAL-WOOL BLANKET 16.0 NOTES: OUTSIDE AIR INSIDE CONDITIONED SPACE,UPSTREAM OF AUTOMATIC SHUTOFF DAMPER AND GREATER THAN 2,800 CFM MINERAL-WOOL BLANKET 16.0 (1) PROTECT PIPING INSULATION PER WSEC C403.10.3.1 OUTSIDE AIR INSIDE CONDITIONED SPACE,DOWNSTREAM OF AUTOMATIC SHUTOFF DAMPER AND GREATER THAN 2,800 CFM MINERAL-WOOL BLANKET 8.0 (2) INSULATION&COVERING ON PIPE&TUBING SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND SMOKE DEVELOPED INDEX OF NOT MORE THAN 450 PER WSBC 720.7. SHEET TITLE: INSULATION MATERIAL&THICKNESS ARE BASED ON CODE MINIMUM EFFICIENCY ONLY.ADDITIONAL PROVISIONS SHALL BE PROVIDED BY CONTRACTOR AS REQUIRED BY LOCAL AUTHORITIES, PROJECT NOTES, OUTSIDE AIR INSIDE CONDITIONED SPACE AND LESS THAN 2,800 CFM MINERAL-WOOL BLANKET 7.0 (3) MANUFACTURER'S INSTRUCTION,OWNER,BRAND STANDARD AND PROJECT SPECIFICATIONS. TABLES& OUTSIDE AIR DUCT IN UNHEATED EQUIPMENT ROOMS WITH COMBUSTION AIR LOUVERS,ISOLATED FROM CONDITIONED SPACE MINERAL-WOOL BLANKET 0.0 ALTERNATE INSULATION MATERIAL:FOR INSULATION WITH CONDUCTIVITY OUTSIDE THE REQUIRED RANGE SHOWN IN TABLE,THE INSULATION SHALL HAVE A MINIMUM THICKNESS AS CALCULATIONS AT SIDES,TOP AND BOTTOM WITH R-11 INSULATION (4) CALCULATED WITH INSULATION THICKNESS EQUATION AS SHOWN BELOW WSEC TABLE C403.10.3.THIS CALCULATION SHALL BE PROVIDED BY CONTRACTOR AND APPROVED BY AHJ. NOTES: (1) DUCT INSULATION SHALL COMPLY WITH IMC AND WSEC. ENGINEERING CAN PROVIDE CALCULATION OR REVIEW CONTRACTORS CALCULATION UNDER SEPARATE CONTRACT OR ADD SERVICE. (2) VAPOR RETARDER IS INSTALLED ON SUPPLY AND OUTSIDE AIR DUCT PER IMC 604.11. (5) REDUCE INSULATION THICKNESS BY 1-INCH TO A MINIMUM INSULATION THICKNESS OF 1-INCH IF PIPE IS IN PARTITIONS WITHIN CONDITION SPACE PER WSEC TABLE C403.10.3 (3) EXTERNAL DUCT INSULATION IS IDENTIFIABLE PER IMC 604.7. (6) OPERATING TEMPERATURE:TYPICAL OPERATING TEMPERATURE RANGE OF EACH SYSTEMS IS SHOWN ON THIS TABLE.CONTRACTOR SHALL VERIFY THE ACTUAL OPERATING TEMPERATURE (4) ALL DUCTWORK IS CONSTRUCTED AND SEALED PER IMC. OF PIPE.IF ACTUAL OPERATION TEMPERATURE OF PIPE IS OUTSIDE TEMPERATURE RANGE,CONTRACTOR SHALL SUBMIT RFI TO ENGINEERING. SHEET NO. (5) INSULATION SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND A MAXIMUM SMOKE DEVELOPED INDEX OF 50 PER IMC 604.3. (7) INSULATION MATERIAL SHALL BE CLOSED-CELL ELASTOMERIC. O•O (8) ALL PIPES SHALL BE INSULATED INDEPENDENT OF ONE ANOTHER. SPLIT HEAT PUMP SCHEDULE -OUTDOOR UNIT COOLING HEATING ELECTRICAL EQUIP NO. SERVICE NOMINCAL SEER/EER HSPF/COP ,SOUND WEIGHT LBS BASIS OF DESIGN(1)(2)(3)(4)(5)(6)(7) CONNECTED CAPACITY,TONS CAPACITY,BTU/H CAPACITY,BTU/H 041F VOLTAGE MCA MOCP PRESSURE,dBA INDOOR UNITS RATED REQUIRED RATED REQUIRED HP-1 DINING 4.0 48,000 16.5/11.3 14.0/- 54,000 11.013.3 8.2/-- 208V/1P 29 44 54 271 MITSUBISHI PUMY-P48NKMU3 FCU-1 cn HP-2 KITCHEN 2.0 24,000 24.7/14.3 14.0/- 29,000 9.3/4.35 8.2/-- 208V/1P 19.0 26 48 165 MITSUBISHI PUZ-A24NHA7 FCU-2 O NOTES: (1) ARI LISTED WITH ALL STANDARD FEATURES,INSTALLATION ACCESSORIES AND COMPRESSOR SHORT CYCLING PROTECTION.FILTER DRIVER,REFRIGERANT LINE FILTER,LIQUID SOLENOID VALVE,AND SAFETY PRESSURE SWITCHES.INSTALL REFRIGERANT TUBING AND LENGTH IN STRICT _0 5 ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION. �" w (2) PROVIDE FACTORY OPTION ELECTRICAL DISCONNECT. (3) ROUTING OF REFRIGERANT LINES FROM INDOOR TO OUTDOOR UNITS NOT SHOWN ON PLANS.CONTRACTOR TO FIELD COORDINATE ROUTING. v (4) ROUTE CONDENSATE TO APPROVED DRAIN. N (5) PROVIDE ALL REQUIRED ACCESSORIES FOR LOW-AMBIENT AND LONG-LINE APPLICATIONS. (6) REFRIGERANT SHALL BE R-410A.FAN SHALL HAVE EC MOTOR. (7) ECONOMIZER NOT REQUIRED PER EXCEPTION 1 C403.5(DOAS).COMMERCIAL SPACE IS VENTILATED BY ERVS. (8) HEAT PUMPS ARE SIZED PER HVAC LOAD CALCULATIONS ON SHEET M8.00. o o z °p❑Oo O oo00 O ❑o0°°�Ne oFvvvsy�ti2°°a SPLIT HEAT PUMP SCHEDULE - INDOOR UNIT DO�osla °aa000° 5,23 FAN ELECTRICAL DIMENSIONS,INCHES SOUND CONDENSATE DRAIN 1 �� MOUNTING/ COOLING HEATING CONNECTED EQUIP NO. SERVICE DISCHARGE MAX AIRFLOW,CFM ESP,WG IN CAPACITY(BTU/H) CAPACITY(BTU/H) VOLTAGE MCA MOCP L �/y H dBA (INCHES)PRESSURE, OUTLET DIAMETER BASIS OF DESIGN(1)(2)(4) OUTDOOR UNIT FCU-1 DINING CEILING DUCTED 1300 0.6 48,000 54,000 208V/1P 4.38 15 29 60 9 44 1-1/4" MITSUBISHI PEFY-P48NMAU-E4 HP-1 FCU-2 KITCHEN CEILING CASSETTE 810 - 24,000 29,000 (3) (3) (3) 38 38 12 36 1-1/4" MITSUBISHI PLA-A24LA(3) HP-2 NOTES: (1) PROVIDE ELECTRICAL DISCONNECT SWITCH AND INDIVIDUAL THERMOSTAT FOR EACH UNIT. (2) PROVIDE INTEGRAL CONDENSATE PUMP KIT AND ROUTE CONDENSATE TO APPROVED DRAIN. ROBISON (3) INDOOR UNIT IS POWERED FROM OUTDOOR UNIT. ENGINEERING,INC (4) THERMOSTAT TO BE INITIALLY SET TO 68°F(ADJUSTABLE). a61aorHnvew,swr LY00,313—66 RNW00636b3E3m REIPFOJEC�N0.:9fi2020 K K K U U (n a a a 0 0 o w z > 3 � Y o U � a in w a w = a O � U Q co W N LL Doo Q O` o U � 05 ° W a J a3� ENERGY RECOVERY VENTILATORS uj Q o3N Q w Z Z FAN ELECTRICAL rn i Oz SENSIBLE INCHES WEIGHT BASIS OF DESIGN d a EQUIP NO. SERVICE FILTER EFFECTIVENESS AIRFLOW, SUPPLY EXHAUST AMPS/ (LBS) (1)(2) _ (� ESP.IN WG / VOLTAGE MOCP L W H CFM FAN HP FAN HP MCA 7 U DIFFUSER SCHEDULE KITCHEN,DINING,STORAGE, O S= Z ERV-1-1 RESTROOMS 900 0.5 MERV-8 74.2% 208V/1P 0.5 0.5 -111.10 15 31 47 18 225 RUSKIN MV 75OXE CALLOUT DESCRIPTION AIRFLOW RANGE, FACE SIZE ENERGY RECOVERY SYSTEM SHALL HAVE THE CAPABILITY TO PROVIDE A CHANGE IN THE ENTHALPY OF THE THE OUTDOOR AIR SUPPLY OF NOT LESS THAN 50 PERCENT OF THE DIFFERENCE BETWEEN THE OUTDOOR AIR AND RETURN 2:_ O (, CFM ,IN BASIS OF DESIGN(1) NOTES: (1) AIR ENTHALPIES,AT DESIGN CONDITIONS. (n O U) Z CD-2 CEILING SUPPLY DIFFUSER 0-350 12x12 TITUS TDC (2) PROVIDE OCCUPANCY SENSORS PER WSEC C403.7.2 TO SWITCH UNIT BETWEEN OCCUPIED AND UNOCCUPIED MODE. L0 RG-7 SIDEWALL RETURN GRILLE 0-850 14x14 TITUS 350ZRL 0 W RG-8 SIDEWALL RETURN GRILLE 0-1700 18x18 TITUS 350ZRL W EG-2 CEILING EXHAUST GRILLE 0-615 12x12 TITUS 350ZRL O Z EG-3 CEILING EXHAUST GRILLE 0-1200 18x18 TITUS 350ZRL F SG-3 SIDEWALL SUPPLY GRILLE 0-350 12x8 TITUS 30ORL v NOTES: (1) ALL DIFFUSERS,REGISTERS,AND GRILLES SHALL BE FACTORY PAINTED. p W a DATE: 11/15/2023 SHEET TITLE: MECHANICAL SCHEDULES SHEET NO M0.02 0(6.7 7 (7.5 8 I I N z 0 I ZN O j DEMO ADDED a WALLS WALL a w 0 II II oc a MERCH REFER ME o SHELVING DISPLAY CASE SHELVING ORDER II (FUTURE) II CONDIMENTS/ TRASH O Z WALL DINING 1300 RE`Eu eEL I F °°oDDDoo 0 FCUMF 1 �ac�°O°o ROOM 00 4 ow\ 000� oF�N;ti?oo (35)SEATS 1,300 o MAX OCC.=49 2C0 TONS o°o ss/QVAL aK� 1,200 CFM °poao1 4-TOP 4-TOP(42"D) (42"D) T T CD-2 KITCHEN ROBISON 175 ENGINEERING,INC 375 375 6Tre AVEw.S111 c2 CD-3 �YNNJl000,WA93036 PREP/ 0636b33E3m 725 1 4� 1 8� reEiPNaccrrvo sfizozo "� COOK S -4 -4 D D PICK-UP o 0 a a a I4-TOP I � 4-TOP 4-TOP -- - 4 42 D 42 D _ I 4 U U , in w a w = a I ES 80 600 ` soli ERV-1-1 � �� ❑ SCULLERY ,' 900 CFM \ I I NGE �- CONDIMENTS/ comws. � TRASH L � �\+ 71 co wN X z-roP 140 140 80 ILL ap ol 2-TOP rac < Q o E —1 E 1 EG 1 U w J N'S WOMEN'S 1 o 1 DRYao 0,5 E 'm-0 o WQa RCH TO (ARCH TO STORAGE > V RIFY) VERIFY) J a 3 LF OF w s =o0 L O O N Q ��z Zo Ella DINING LL: _ � (� / COUNTER 7 •Q Z O ADDED V G 0 _ WALL O (J) Z I�..I C o0 mw a W LEVELI H V A C PLAN . - * DATE 5,2023 SCALE: 1/4" — 1'-0' ` SHEET TITLE: 5 7 ❑ I SHEET N0. M2.01 Z O Z N O j F- W w 0 w i_ 0 HP-1 0 DINING Z �-`- -- z,� 4.0 TONS 271 LBS o°°oAc�Ooo o° E.. s o O _____ 000�';e�oFvuvSyiti�?O°p0 O o O° ss/QVAL EtF'�oO00 H P—2 °paa000°°5 23 KITCHEN �� 1 2.0 TONS 165 LBS � ' r: ROBISON ENGINEERING,INC i aorH AVEw,swrc3c Nw000,WA93036 LY R0636b3 0 9 RN]"RC�N ROCK. AD 020 K K K U U (n a a a 0 0 o w 'w 3 o z Y U � a in w a w T a O � U Q O O M w N LL 0No Qa o o U � 06 ° W a J a3� ED Q ogN Q W Z Z Oa d °z � U Z Zz 0 - 0 U) z Lo C) 0 m-, W w o m w U ROOF H VAC PLAN a W DATE: 11/15/7 SCALE: 1/4" — 1'-0" SHEET TITLE: SHEET NO M2.02 FUNCTIONAL DEVICES TERMINALS ON DELAY RELAY HVAC UNIT #RIBD0IBDC OR EQUAL THAT 5-MINUTE DELAY ENABLE/DISABLE (MC) HATING& COOLING 120V POWER BLU _____________ 120VAC PER � N N/C POWER PLAN _ YEL C DISCONNECT N SWITCH N pG LOW VOLTAGE HVAC UNIT O (EC) WIRING (MC) z 'n 0 > (MC) LOW VOLTAGE a it DOOR CONTACTS DRY CONTACT INPUT v TO CLOSE WHEN N DOOR OPENS I o (MC) r — SEQUENCE OF OPERATION LOW VOLTAGE CONTROL 1. PROVIDE CONTROLS TO DISABLE HATING&COOLING ON HVAC o INPUT WIRING UNIT WHEN OUTSIDE DOOR REMAINS OPEN 5 MINUTES OR (MC) LONGER,PER WSEC C403.4.1.6. 2. WHEN ENTRY DOOR IS OPENED,THE DOOR SWITCH CONTACT o CLOSES AND SIGNALS DELAY RELAY TO START DELAY z PROVIDE KADTRONIX HVAC SEQUENCE. HEN ESMART QUIVALENT SYSTEM OR 3 H AS OWNER PROPS DOOR OPEN ON A NICE DAY),THE HEATING NT & OO�po AC�000 COOLING ON THE HVAC UNIT IS DISABLED. <v; oFv�wsy� 4. THE FAN CAN STILL OPERATE TO CIRCULATE AIR. p'p00 OO tie ti ? a 5. WHEN THE DOOR CLOSES,THE CONTROLS ENABLE HEATING& ❑ COOLING. ❑ NOT USED HEATING/COOLING DISABLE WITH DOOR SWITCH 6 HTHE EATING OSEOOLING F THESE CONHENTROLS IS TO IS PREVENT LEFT WASTING �p0^F99/ONAL EtF'�oOO DETAIL 6 DETAIL MAIN ENTRY DOOR 1 p�p❑❑0015 �3 (NOT TO SCALE) 11' SCALE:NONE M4.00 SCALE:NONE M4.00 �w ROBISON ENGINEERING,INC '—EW.SUITE— NW000WA93036 LY R0636b33E3m RNIT'--N0.:9fi2020 K � K U U (n a a a 0 0 o w z > 3 � Y o U � a in w a NOT USED NOT USED NOT USED `o w N DETAIL DETAIL 4 DETAIL z < 00 Q °l N SCALE:NONE M4.00 SCALE:NONE M4.00 SCALE:NONE Wo wed � a J a 3 M C xp to w Q ogN Q Z w Z O d °'tea V U Z Zz O cn o U) z 0 wL mW w LaU W DATE: 11/15/2023 SHEET TITLE: MECHANICAL DETAILS NOT USED NOT USED NOT USED DETAIL DETAIL DETAIL SHEET NO. SCALE:NONE M4.00 SCALE:NONE M4.00 SCALE:NONE /M4.00 M4.00 Z ) Z Vl O j F- W 0 0 0 z °popoopo° o°O°°�Ne oFWasy/ti��°Oa 11/1523,1:08 PM den hvaotoatlsl.hMl 11/1523,198 PM den hvaoloatlsl.hMl 11/15/23,198 PM cm_hvac-loadst html O Load Total Summary-System Room Information,Part 2 (tacludes Ventilation and Plenum Loads) Felues in i(dics have been changedfromthe d�uh Project Information °°o Si ,L pO°o Conlin Hearin Pmjeet Name: �l7ED° (Ji23 g 8 Equipment Load People Glass Lontion Area bmh Tons Number Lighting Load Pmjeet Location: Arlington,WA D2/ CFM/ CFM/ CFM/ Sensible Latent Sensible bmh/Person Latent bmh/Persov Zone Type - CFM Peak CFM bmh kW Heating Safety Factor(Roam): 0% Total Sensible Latent Total Sensible Lalenl ma ton it2 BZ D]NIG ROOM 0.8 watts/fl 7,160 0 0 43 people 275 275 B Default Heating Temperamre: 68°F 1,610 Heatvg Safety Factor(Vevtilatiov): 0% Zone Default OS 1,450 July 12'' 60,800 36,600 24,200 5.1 3.1 2 318 285 0.9 1,450 20,600 6.1 0.9 KITCHIN 0.8 watts/0 1,240 11.5 watts/fl2 776 0 to people 375 625 B Coaling Safety Factor(Ruom): 0% Tempered OSA tl2 P.m. Dafadt Cooling Temperamre: - F Cooling Safety Factor(Ventilation): 0% Room DINING L160 5:00 ROOM a 1,170 July P m 46,400 29,700 16,700 3-9 2.5 .4 300 304 1.01 725 17,300 5.1 0.63 Default Relative Humidity: 50°° Floor Slab Heal Lms Coeificiem: 0.54 3:00 Ventilation Schedule Calculation Date: November 15,2023,1:08 pm. Room KITCHEN 455 ft 2711Wy p m 14,4fq 6,900 7,470 1.2 0.6k..6 3R0 226 0.6 175 3,310 1 0.39 Design Conditions D O B I O N Ventilation Area Ventilation Supply Ventilation R Location Room-type Requirements (R2) People CFM CFM % OSA Low: 18°1 Latitude: 48°N Zane Default- OSA Daily Range: 16°1 Elevation: g2' ENGINEERING,INC 1,610 53 900 1,450 62 not notry nvrw,surtssc� Load Total Summary-Room Tempered OSA OSA High Dry Bulb OSA High Wet Bulb rvrvw000 wnasosc Room DNIG (SMC/WSMC 2018)Dmmg Room- July 86°F 68°F 2o69aa-- (Excludes Ventilation and Plenum Loads) ROOM (Food Service) Direct 1,160 43 725 1,170 62% reNiCON PRWTPC o..9a2a2o AD Cooling Healing Locatioe Area bluh Tons (SMC/WSMC 2018)Ki[chea Cookmg- CFM Peak ft2/ CFM/ CFM/CFM bmh kW CFM/ Room KITCHEN (Feed F�Service) Direct 455 10 175 Tom]Sensible Lalenl MW Sensible Latent ton toe fl2 D2 Wall Types Zone Default- 1,610 1 450 CV-Sum of 50200 31,700 18,400 4.2 2.6 I.5 386 346 0.9 900 8,040 2.4 0.56 Wan Type D-Yams ASHRAE Type Color Descrill Tempered OSA R2 Peaks Edisoa's Cafe Wall 0.078 1 Dark Mass Wall(2015 WA Mmimum) K K Room DB4I]G 1,160 5�00 Cooling Load Details-System ROOM tt21,170 July Pm. 37,800 25,80012,100 3.2 22 1 367 372 1.01 7257,180 2.1 0.63 (Btdh/%Total) a a a 3:00 (See"Cooling Load Derails-Room-for lighting,equipment,and people loads) Walls Room KITCHEN 455 ftz 271 July I2,300 5,960 6,350 1 OS 0.5 443 264 0.6 175 861 0.3 0.39 W P.m. Ventilation InDNration Room Number Length Height Area(Minus Doors and Glass) Type Facing Direction On Perimeler Z Z y O Location Peak Roof W.I. Class Sensible Latent Sensible Latent 3 O U DINING ROOM 31'-8" 10' 215 R Edison's Cafe Wall W Zone Default-T pemd OSA July 12.00 p.m. 0 0% 1,920 3% 8,470 14% 4,151 8% 5,760 9% 584 1% 352 1% K w S d Room DINING ROOM July 5:00 p.m. 0 0% 1,920 4% 8,470 IS% 3,900 8% 4'640 10% 395 1% 249 1% DINING ROOM 3'-9" 10 38 R2 Edison's Cafe Wall W O U Q Room KITCHEN July 3011p.m. 0 0% 0 0% 0 0% 942 7% 1,120 8% 190 1% 102 1% DINING ROOM IS' l0' 150 R2 Edison Cafe WA S Cooling Load Details-Room Glass Types (B./h/%of Total) On.Type D-Value I SHGC I Deacripthm Location Peak Roo Wall I Glaas I Lighting Equipment People Infiltration Edisw's Cafe Glazed Door 0.6 0A 2015 WA Min Window(Entrance Door) Sensible Latent Sensible Latent Sensible Latest EdiaoWs Cafe Window 0.38 0.4 2015 WA Min Window(Metal Framed,Fired) Zone Default-T pered Cv-Sum of Pek OSA Pes 00%1,9204%8,47017%4,400 9%7762%0 0%15,60031%18,10036%5841%3521% ak Glass Room DINING ROOM July 5:00 pm. 0 0°/1920 5%8,470 22%3,160 B% 0 0%0 0%11,800 31%11,800 31%395 1%249 1 Room KITCHEN July 3:00p.m. 00% 01-1 0(11,240 10%776 6%0 0%3,75030%6,25051%1%2%1021% Raom Number Area Type Facing Direction Shaded DINING ROOM 21 ft Fdisou's Cale Glazed Door W DINING ROOM 80 1112 Ediaon's Cafe Window W CY) W N Heating Load Details-System and Room L L 04 (Btu/b/%of Sysmm Total) 01 Location Roof Wall Glass Slab Ventilation Infiltration,Infiltration, Room Information,Part 1 Q Q N Zone Default-T OSA 0 0% 1,570 8% 2,150 10% 1,360 7% 12,600 61% 2,960 14% 0 a� Fdues in italics have been changedfmm the def uh cn tu Room DI4ING ROOM 0 0% 1,570 9% 2,150 12% 1,360 8% 10,100 59% 2,100 12 Ceiling Ventilation Infiltration Cooling Heating Relative Room KITCHEN 0 0% 0 0% 0 0% 0 0% 2,450 74% 861 26% Number Name Area W M Height C--; Heating CooHag Hcatiag Temperamre Temperamre Humidity _�( (SMC/WSMC 2011) 0.25 {J(� _O �00 M DINING 1,160 125 Same as 725 39 Setae as 39 Dining Room- 8'Direct AC/ 75°F 68°F 50•/ ROOM (F�Service) t12 CFM cooling CFM hom CFM cooling CFM J Q (SMC/WSMC 2018) 0.25 •� H O p 455 175 Same as 175 16 Same as 16 O KITCHEN Kitchen Cooking- I'Di- AC/ 75°F 68°F 50•A O (Food Service) 11? CFM cooling CFM hour CFM cooling CFM Q Q 3 tit Z Z O fileJW:/962 Gmadsiew NoM LLU962-028 Edisoes Cafe Mington,WA/Dwg/dm_hvaaloadsl.html 3/3 file:///F:1%2 GmMview North LLC/%2-028 Edisous Cale Atlington,WAM-91dm_hvaaloads1.henl 2/3 file:i//F:1%2 GMMWew NoM LLC/%2-028 Edi.o s Cafe Mington,WA/Dwgfdm_hvaaloadsl.hbnl 1/3 �/) U Z Zz 0 60 o (j) z �, w0 mW w U a W DATE: 11/15/2023 SHEET TITLE: HVAC LOAD CALCULATIONS SHEET NO M8.00 GENERAL NOTES SYMBOLS ABBREVIATIONS 1. REFERENCE TO RELATED WORK:"REF"INDICATIONS DENOTE WORK COVERED ELSEWHERE(ARCHITECTURAL, GENERAL PIPE SYMBOLS ABV ABOVE FPM FEET PER MINUTE OPD OVER PRESSURE DEVICE STRUCTURAL,CIVIL,ELECTRICAL,LANDSCAPE,OR KITCHEN),OR ITEM BASED ON A SPECIFIC MANUFACTURER'S AD AREA DRAIN FPS FEET PER SECOND OPNG OPENING DIMENSIONS(VERIFY). ARCHITECTURAL BACKGROUND Cl TOP PIPE CONNECTION AFF ABOVE FINISHED FLOOR FS FLOOR SINK P PUMP (THIN LINE) AHJ AUTHORITY HAVING JURISDICTION FT FEET PD PRESSURE DROP,PLANTER DRAIN 2. ELECTRICAL CHARACTERISTICS:REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS(VOLTAGES, BOTTOM PIPE CONNECTION BFF BELOW FINISHED FLOOR FU FIXTURE UNITS POC POINT OF CONNECTION ETC.OF MECHANICAL EQUIPMENT,UNLESS OTHERWISE INDICATED. T BFP BACKFLOW PREVENTER G GAS(LOW PRESSURE) PRV PRESSURE REDUCING VALVE NEW PIPING(HEAVY LINE) _ 0 PIPE TURNING UP BOH BACK OF HOUSE GAL GALLONS PRESSURE RELIEF VALVE 3. CODES:COMPLETE INSTALLATION OF THE PLUMBING SYSTEM SHALL BE PER THE APPLICABLE BUILDING, Bp BOOSTER PUMP GO GARAGE DRAIN PS PUMPED STORM DRAINAGE MECHANICAL,ENERGY,PLUMBING,FIRE,AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL AHJ. BT BATHTUB GM GAS METER PSIG POUNDS PER SQUARE INCH GAUGE z rn EXISTING PIPING(THIN LINE) PIPE TURNING DOWN/DROP BTUH BRITISH THERMAL UNIT PER HOUR GPG GRAINS PER GALLON PSD PUMPED STORM DRAINAGE F z 4. PREPARE AND SUBMIT FOR REVIEW A SHOP DRAWING BASED ON FINAL STRUCTURAL SHOP DRAWINGS FOR C COMMON GPM GALLONS PER MINUTE PSS PUMPED SANITARY SEWER a 2 LOCATING AND ROUTING ALL EQUIPMENT,PIPING,ETC. EXISTING WORK TO BE REMOVED 7 PIPE CAP CAP CAPACITY GV GATE VALVE PSW PUMPED SANITARY WASTE O w A. COORDINATE FLOOR AND BEAM PENETRATIONS WITH STRUCTURAL. PIPE PLUG CB CATCH BASIN GWB GYPSUM WALLBOARD PW PUMPED WASTE w w B. COORDINATE FINAL LOCATION AND ROUTING WITH CEILING,LIGHTS,WALLS,FIRE SPRINKLER PIPING,AND CD CONDENSATE DRAIN GWH GAS WATER HEATER RD ROOF DRAIN o OTHER TRADES WORK. - - MATCHLINE OR PROPERTY LINE, UNION CFF CAPPED FOR FUTURE HB HOSE BIBB REF REFERENCE C. INCLUDE ADDITIONAL OFFSETS,ELBOWS,ROUTING,EQUIVALENT DUCT SIZING EXCHANGE,RELOCATING,ETC. CFM CUBIC FEET PER MINUTE HD HEAD RPBP REDUCED PRESSURE BACKFLOW AS REQUIRED FORA COMPLETE OPERATING MECHANICAL SYSTEM. �i FLANGE CI CAST IRON HDR HUB DRAIN PREVENTER D. PROVIDE SHOP DRAWINGS AT NO ADDITIONAL COST TO THE OWNER. CONNECTION TO EXISTING CLG CEILING,COOLING HEDV HOSE END DRAIN VALVE RPM REVOLUTIONS PER MINUTE o WYE STRAINER CLW CLOTHES WASHER HORIZ HORIZONTAL S SINK 5. PLUMBING CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF ALL PLUMBING EQUIPMENT WITHIN CO CLEANOUTS HP HORSEPOWER SCH SCHEDULE THE STRUCTURE. SECTION IDENTIFICATION WYESTRAINER WITH CAPPED HOSE COMB COMBUSTION HPCW HIGH PRESSURE COLD WATER SCW SOFTENED COLD WATER END BLOWDOWN VALVE CONT CONTINUE,CONTROL HW HOT WATER SD STORM DRAIN END O 6. ACCESS DOORS:COORDINATE WITH ARCHITECT AND LOCATE ALL ACCESS DOORS ON SHOP DRAWINGS PRIOR TO INDICATES DIRECTION OF CUTTING CONTR CONTRACTOR HWC HOT WATER RE-CIRCULATION SEP SEWAGE EJECTOR PUMP z BEGINNING OF CONSTRUCTION.ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE FIRE RATED.VERIFY ACCESS PLANE VALVE COTG CLEANOUTS TO GRADE HWCP HOT WATER CIRCULATION PUMP SF SQUARE FOOT DOOR LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO BIDDING. CP CIRCULATING PUMP HWR HOT WATER RETURN SGSV SEISMIC GAS SHUTOFF VALVE LETTER INDICATES SECTION BALL VALVE CV CHECK VALVE HWST HOT WATER STORAGE TANK SH SHOWER pOOD00p 7. ROOF PENETRATIONS:SEE ARCHITECTURAL DRAWINGS FOR ROOF CAP,ROOF CURB,ROOF DRAIN,OVERFLOW (NO.INDICATES DETAIL) CW COLD WATER HX HEAT EXCHANGER SO STORM OVERFLOW �O Q J q�SOS D DIAMETER ICW INDUSTRIAL COLD WATER SP STATIC PRESSURE/SUMP PUMP E P DRAINS AND VTR DETAILS. A GLOBE VALVE �v:' J A O DB DRY BULB,DECIBEL ID INDIRECT DRAIN,INSIDE DIAMETER SR SUDS RELIEF 8. EXPOSED PIPING:PROVIDE CHROME PLATING FOR EXPOSED PIPING IN FINISHED ROOMS. P-3 P 3 SHEET NUMBER WHERE SECTION IS CHECK VALVE DF DRINKING FOUNTAIN IE INVERT ELEVATION SS STAINLESS STEEL/SANITARY SEWER DRAWN DFU DRAIN FIXTURE UNITS IHW INDUSTRIAL HOW WATER SSS SIDE SANITARY SEWER 9. PENETRATIONS:PROVIDE ESCUTCHEON PLATES FOR EXPOSED PIPING PENETRATIONS AND SHEET METAL FLASHING SHEET NUMBER WHERE SECTION IS ^�� DI DUCTILE IRON IN INCH STD STANDARD ��� BALANCING OR PLUG VALVE .p sn EO FOR EXPOSED DUCTWORK PENETRATIONS. TAKEN DIM DIMENSION KS KITCHEN SINK SQ SQUARE D ...,.i BUTTERFLY VALVE DIN DOWN KW KILOWATT TO TRENCH DRAIN 10. SHAFT AND PLENUM CONNECTIONS:SEAL CONNECTIONS TO AIR SHAFTS AIRTIGHT.PROVIDE AIRTIGHT SEAL DS DOWN SPOUT L LONG,LENGTH TMV THERMOSTATIC MIXING VALVE �OOppp `.3 AROUND PENETRATIONS IN AIR PLENUMS. DWG DRAWING LAV LAVATORY TP TRAP PRIMER ,11,15�2 DETAIL IDENTIFICATION FLEXIBLE FLEXIBLE CONNECTION IN PIPING (E) EXISTING LB POUND TYP TYPICAL 11. LIGHT FIXTURE CLEARANCE:COORDINATE LOCATIONS OF MECHANICAL WORK TO PROVIDE CLEARANCES OVER EFF EFFICIENCY M WATER METER UH UNIT HEATER LIGHTING FIXTURES FOR REMOVAL AND REPLACEMENT. DETAIL NUMBER ELEC ELECTRIC MBH THOUSAND BTU PER HOUR UON UNLESS OTHERWISE NOTED DRAWING/SHEET NUMBER EQUIV EQUIVALENT MECH MECHANICAL UR URINAL 12. CABLE TRAYS:PIPING INSTALLED ADJACENT TO ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM ACCESS OF 6" --- PRESSURE REDUCING VALVE(PRV) EWC ELECTRIC WATER COOLER MCA MIN.CIRCUIT AMPACITY V VENT ABOVE AND TO THE SIDE OF CABLE TRAYS. PRV EWH ELECTRIC WATER HEATER MOCP MAX.OVER CURRENT PROTECTION VTR VENT THRU ROOF pp EXT EXTERIOR,EXTERNAL MPG MEDIUM PRESSURE GAS W WASTE,WATT,WIDE 13. MOTORS:COMPLY WITH ENERGY CODE ENFORCED BY AHJ FOR MINIMUM EFFICIENCIES UNDER FULL LOAD. 1 AUTOMATIC CONTROL VALVE,2-WAY F FAHRENHEIT MTD MOUNTED WC WATER CLOSET Ro BI SON EQUIPMENT �/�> FCO FLOOR CLEANOUTS (N) NEW WCO WALL CLEANOUTS 14. ACCESS CLEARANCES FOR MAINTENANCE AND REPLACEMENT:VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO /�� FD FLOOR DRAIN NC NORMALLY CLOSED WHO WALL HYDRANT ENSURE THAT ACCESS CLEARANCES CAN BE MET.COORDINATE LOCATIONS OF MECHANICAL WORK AND WORK OF TYPICAL EQUIPMENT DESIGNATION AUTOMATIC CONTROL VALVE,3-WAY FDC FIRE DEPARMENT CONNECTION NO NORMALLY OPEN WM WASHING MACHINE ENGINEERING,INC OTHER TRADES TO PROVIDE ACCESS CLEARANCES FOR SERVICE AND MAINTENANCE. FF FINISHED FLOOR OD OUTSIDE DIMENSION/DIAMETER WSFU WATER SUPPLY FIXTURE UNITS isw,amHn ..-2 HWCP-1 FLR FLOOR OVERFLOW DRAIN/DECK DRAIN L 36 2069 3E3- COORDINATION REQUIREMENTS ID RELIEF VALVE pCOn acr crrEe0reaci- 1. IRRIGATION SYSTEM:COORDINATE IRRIGATION WATER DEMAND,MINIMUM WATER PRESSURE REQUIREMENTS& CONTRACTOR SUBSTITUTIONS & REVISIONS CONTROL CABINET LOCATIONS WITH IRRIGATION CONTRACTOR. PIPING ��� BALANCING/MEASURING VALVE 2. GAS:CONTRACTORIGAS COMPANY SHALL FINALIZE GAS METER AND GAS SERVICE LOCATIONS.INSTALL SEISMIC -W- WASTE BELOW GRADE REDUCER O O 0 GAS SHUT OFF VALVE PER GAS COMPANY REGULATIONS. PLEASE SUBMIT PROPOSALS FOR SUBSTITUTIONS OR REVISIONS FOR REVIEW AND APPROVAL PRIOR TO ORDERING MATERIAL OR DOING 13 W WASTE ABOVE GRADE DIRECTION OF FLOW WORK.FOR EQUIPMENT THAT IS SCHEDULED BY MANUFACTURER'S NAME AND CATALOG DESIGNATIONS,THE MANUFACTURER'S PUBLISHED Y 3. UTILITIES:COORDINATE WITH SITE UTILITY CONTRACTOR AND CIVIL DRAWINGS FOR UTILITY CONNECTIONS AND PVy PUMPED WASTE DATA AND/OR SPECIFICATION FOR THAT ITEM ARE CONSIDERED PART OF SPECIFICATION.ENGINEERING COSTS FOR REVISING MEP PLANS EXTENSIONS. A SHALL BE ADDRESSED IN THE COST ANALYSIS OF THE SUBSTITUTION PROPOSAL.CONTRACTOR TO COORDINATE WITH ENGINEER AND o j IW INDIRECT WASTE �� PIPE ANCHOR DETERMINE ASSOCIATED DESIGN AND PERMITTING COSTS.CONTRACTOR SHALL BE RESPONSIBLE FOR OTHER COSTS ASSOCIATED WITH Y O 4. ROOF DRAINAGE:COORDINATE WITH GENERAL CONTRACTOR FOR ROOF DRAIN AND OVERFLOWS,SCUPPER DRAINS, PIPE ALIGNMENT GUIDE UNFORESEEN ISSUES RESULTING FROM SUBSTITUTIONS OR REVISIONS. O CL 0: AND CONDENSATE DRAINS. SS SANITARY SEWER ABOVE GRADE o wo L"I -SS- SANITARY SEWER BELOW GRADE PIPE SUPPORT NOTE TO CONTRACTOR 5. PLUMBING FIXTURES&EQUIPMENT:COORDINATE EXACT LOCATION OF ALL PLUMBING FIXTURES&EQUIPMENT WITH i PS ARCHITECTURAL AND OTHER TRADES DOCUMENTS. -V- VENT VALVE STATION OR ASSEMBLY 6. PIPING:COORDINATE EXACT LOCATION OF ALL STRUCTURAL FRAMING&FOOTINGS AND FINALIZE THE EXACT RL RAIN LEADER ROUTING OF ALL PIPES WITH STRUCTURAL ENGINEER AT THE SITE PRIOR TO AND DURING THE CONSTRUCTION. ORL OVERFLOW RAIN LEADER y ID INDIRECT DRAIN,PIPE TO DRAIN DRAWINGS ARE DIAGRAMMATIC,SHOWING THE GENERAL LOCATION,TYPE,LAYOUT,AND EQUIPMENT REQUIRED.THE COORDINATE UNDER GRADE PIPING&FOUNDATION DRAINAGE PIPING WITH CIVIL ENGINEER. DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENT.REFER TO ARCHITECTURAL DRAWINGS FOR CD CONDENSATE DRAIN DIMENSIONS.REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND 7. ADJUSTMENTS:ALL EQUIPMENT,MOTORS,FANS GAS BURNERS,IGNITION DEVICES,DRIVES,ETC.SHALL BE - COLD WATER(CW) POINT OF CONNECTION INSTALLATION REQUIREMENTS.PROVIDE DUCTWORK,CONNECTIONS,ACCESSORIES,OFFSETS,AND MATERIALS ADJUSTED AND BALANCED TO OPERATE AT SPECIFIED RATINGS AS REQUIRED FOR THIS PROJECT SITE AND NECESSARY FOR A COMPLETE SYSTEM. ACCOUNTING FOR ELEVATION ABOVE SEA LEVEL. HOT WATER(HW),POTABLE,120-F O O RD OD ROOF DRAIN,OVERFLOW DRAIN 8. APPROVALS:MECHANICAL AND PLUMBING EQUIPMENT SHALL BE APPROVED FOR INSTALLATION IN THE PROJECT -- -140 HOT WATER,POTABLE, APPLICABLE CODES LOCATION AND SHALL HAVE ALL CERTIFICATIONS AND RATINGS TO MEET ALL ENERGY,POLLUTION, TEMPERATURE OTHER THAN 120°F ENVIRONMENTAL,SEISMIC,APPLICABLE CODES AND REGULATIONS.THE CONTRACTOR SHALL COORDINATE WITH ® o❑ FLOOR DRAIN (h MANUFACTURE SUPPLIERS AND SHALL INCLUDE ALL COSTS REQUIRED TO MEET THE BID DOCUMENTS. --- HOT WATER CIRCULATING(HWC), N POTABLE,120"F 9. FIRE PROTECTION:CONTRACTOR SHALL PROVIDE A FULLY DESIGNED FIRE PROTECTION SPRINKLER SYSTEM IN HOSE BIBB U- ON THE FOLLOWING PROJECT DESIGN IS BASED ON THE FOLLOWING CODES: O COMPLIANCE WITH NFPA AND LOCAL CODES.PROVIDE DESIGN,PERMITS,MATERIALS,INSTALLATION,TESTING AND - ----140 HOT WATER CIRCULATING,POTABLE, 01 ALL OTHER FORA FULLY OPERATIONAL SYSTEM.LOCATION OF ALL PIPING TO BE COORDINATED WITH OTHER TEMPERATURE OTHER THAN 120"F -20181NTERNATIONAL BUILDING CODE(IBC)&WASHINGTON STATE AMENDMENTS TRADES. i BREAK IN PIPING OR DUCTWORK -2018 INTERNATIONAL MECHANICAL CODE(IMC)&WASHINGTON STATE AMENDMENTS Q o FOF FUEL OIL FILL I� -2018 UNIFORM PLUMBING CODE(UPC)&WASHINGTON STATE AMENDMENTS m 10. PRIOR TO PIPING INSTALLATION:PLUMBING CONTRACTOR TO COORDINATE PIPING LAYOUT WITH ALL OTHER GAS METER -2018 WASHINGTON STATE ENERGY CODE(WSEC) ao TRADES. FOS FUEL OIL SUPPLY c p�M FOR FUEL OIL RETURN INLINE WATER METER w°� 11. ACCESS:COORDINATE ALL ACCESS LOCATIONS WITH GENERAL CONTRACTOR AND ARCHITECT TO ENSURE ALL a 3 REQUIRED ACCESS HATCHES,ACCESS PANELS&ACCESS COVERS ARE PROVIDED. DRAWING INDEX-FOV - FUEL OIL VENT PUMP J m O o 12. PROVIDE&INSTALL WATER TIGHT SEALS FOR ANY PIPING PENETRATING THE EXTERIOR FOUNDATION WALLS OR -RV- RELIEF VENT (� w Q 80 8 3 o SLABS. Y PRESSURE GAUGE o Z O G LOW PRESSURE NATURAL GAS rn za 13. ANY DISCREPANCIES SHOULD BE REPORTED TO THE ARCHITECT IMMEDIATELY. '^ MPG MEDIUM PRESSURE NATURAL GAS y THERMOMETER ,,I v I U 14. PROVIDE&INSTALL FIRE PROOFING FOR ALL PIPING PENETRATING FIRE BARRIER WALLS OR FLOOR SLABS. Drawing Index Q z Z IRR IRRIGATION(NON POTABLE) t PR PRESSUREITEMPERATURE TEST PORT DISINFECTION OF POTABLE WATER SYSTEM REQUIREMENTS (m N O O 1. NEW OR REPAIRED POTABLE WATER SUPPLY SYSTEMS SHALL BE DISINFECTED PRIOR TO USE. Sheet Number Sheet Title 2:-E �_ O Vl Z REDUCED PRESSURE BACKFLOW y �a~~D - PREVENTER a' 2. INITIAL COLIFORM SAMPLE IS REQUIRED PRIOR TO ADMINISTERING WATER-CHLORINE SOLUTION. RPBP Q L0 P0.0 LEGEND,GENERAL NOTES,AND DRAWING INDEX X w N M W 3. SECTION 609.9 ITEMS#2 OR#3 CAN BE USED PRECEDED BY AND FOLLOWED BY ITEM#1. �Q"�N X- DOUBLE CHECK VALVE ASSEMBLY W W 3.1. NOTE FILL PORT TO ADD CHLORINE MUST BE WHERE WATER SUPPLY ENTERS BUILDING AND A FLOW METER TO DCVA P0.1 PLUMBING NOTES AND TABLES X MEASURE SOLUTION. I 1 O Z w 4. AFTER WATEROCHLORINE SOLUTION IS INCORPORATED INTO THE NEW OR REPAIRED WATER SUPPLY SYSTEM A 48 CATCH BASIN P0.2 PLUMBING CALCULATIONS&SCHEDULES X aZ HOUR WAITING PERIOD MUST BE OBSERVED PRIOR TO BACTERIOLOGICAL TEST. I I I TRENCH DRAIN P0.3 PLUMBING SCHEDULES X W 5. BACTERIOLOGICAL TEST SHALL BE CONDUCTED BY A LABORATORY CERTIFIED FOR DRINKING WATER IN STATE AFFIRMING WATER QUALITY CONTAINS NO COLIFORM BY SAMPLE TESTING THE FURTHEST FIXTURE FROM PUBLIC ------� EMERGENCY GAS SHUT-OFF VALVE P2.0 UNDERSLAB WASTE&VENT PLAN X WATER SOURCE AND NOT LESS THAN TWO OTHER LOCATIONS PART OF THE WATER SUPPLY SYSTEM. TE: 11/15/2023 P2.1 LEVEL 1 WASTE&VENT PLAN X 6. CHLORINE LEVEL IN THE NEW OR REPAIRED WATER SUPPLY SYSTEM SHALL NOT BE LESS THAN THE MEAN AVERAGE T GAS SEISMIC SHUT-OFF VALVE OF THE AREA IN RELATIONSHIP FROM THE WATER PURVEYOR SOURCE. P3.0 UNDERSLAB SUPPLY PLAN X SHEET TITLE: 7. WARNING:IN CASE A WATER SOFTENER IS PART OF THE COLD WATER SYSTEM,CONTRACTOR TO ENSURE THE WASHER BOX P3.1 LEVEL 1 SUPPLY PLAN X LEGEND,GENERAL WATER SOFTENER IS CONNECTED AND OPERATIONAL BEFORE STARTING THE DISINFECTION PROCESS.FAILURE TO /��, NOTES,AND FOLLOW THE INSTRUCTIONS WILL VOID THE WATER HEATER OR HEAT PUMP WARRANTY. (%//,1 GREASE INTERCEPTOR P4,0 WASTE&SUPPLY DIAGRAMS X WING INDEX P6.0 DETAILS X P6.1 DETAILS X SHEET NO. P0.0 PLUMBING TABLES PLUMBING NOTES 1. CONNECTIONS:PROVIDE PLUMBING FIXTURE CONNECTIONS TO BUILDING WASTE,VENT,COLD WATER,AND HOT WATER SYSTEM IN ACCORDANCE WITH 23. REDUCERS:PROVIDE AS REQUIRED FROM LINE PIPE SIZE TO EQUIPMENT, DRAWINGS,MANUFACTURER'S RECOMMENDATIONS,AND LOCAL CODES. TRAP,COIL,AND CONTROL VALVE CONNECTION SIZES. CONNPLUMBING FIXTURE FLOW RATES PER WAC 51-56-0400 VALVE,VACUUCT TO BREAKERS REGULATORS, S,UNIONSC.WITH ALL ACCESSORIES, VALVES,VACUUM BREAKERS,REGULATORS,UNIONS,ETC.AS REQUIRED AND 24. VALVE TAGS:PROVIDE VALVE TAGS PER SPECIFICATIONS TO IDENTIFY VALVE AS RECOMMENDED BY THE MANUFACTURERS.REFER TO PLUMBING FIXTURE AND THE AREA IT SERVES. Z N O CONNECTION SCHEDULE ON PLANS. F O 25. OFFSETS:PROVIDE FOR BRANCH LINES TO EQUIPMENT. a D FIXTURE TYPE MAXIMUM FLOW RATE NOTES HANGER SPACING FOR 2. HOT AND COLD:WATER PIPING CONNECTION TO EACH FIXTURE SHALL BE U w WASTE AND VENT PIPING SIDE. WATER ON THE RIGHT HAND SIDE AND HOT WATER ON THE LEFT HAND 26. SALL TANDARD9ATORE MIXING VALVES SHALL COMPLY WITH ASSE-1070 SAFETY w w p SHOWERHEADS 1.8 GPM @ 80 PSI 1 LAVATORY FAUCETS,RESIDENTIAL 1.2 GPM @ 60 PSI 2 ALL SUSPENDED SANITARY AND VENT PIPE SHALL BE SUPPORTED AS 3. HOT WATER:NON-CIRCULATING HOT WATER PIPE SHALL NOT EXCEED 10, 27. PROVIDE PIPE MARKER WITH DIRECTION OF FLOW.LABEL"NON-POTABLE LAVATORY FAUCETS,PUBLIC&NON-RESIDENTIAL 0.5 GPM @ 60 PSI 3 FOLLOWS PER 2018 UPC TABLE 313.3: UNLESS OTHERWISE SHOWN ON DRAWINGS. WATER DO NOT DRINK"CLEARLY ON NON-POTABLE WATER PIPING. MAX.HORIZ. MAX.VERT. p METERING FAUCETS 0.25 GALLONS PER CYCLE 3 SPACING SPACING 4. VENT STACKS:COORDINATE VENT STACK WITH HVAC EQUIPMENT TO MAINTAIN 28. PROVIDE EXPANSION LOOPS/EXPANSION JOINTS IN PIPING PER 2018 UPC SINKS 2.2 GPM @ 60 PSI 4 ASS 4 FT. 10 FT. MINIMUM 10'CLEARANCE FROM OUTSIDE AIR INTAKES. TABLE 313.3 AND MANUFACTURER INSTALLATION INSTRUCTIONS. KITCHEN FAUCETS 1.8 GPM @ 60 PSI 5 CAST-IRON HUBLESS' EVERY OTHER 15 FT. 5. CLEANOUTS:PROVIDE CLEANOUTS PER CURRENT UPC AND AS REQUIRED BY 29. PROVIDE APPROVED PIPE HANGERS&PIPE SUPPORTS IN ACCORDANCE WITH p PRERINSE SPRAY VALVES 1.6 GPM @ 60 PSI 6 JOINT LOCAL JURISDICTIONS.CLEANOUTS SHALL BE LOCATED IN WALLS/FLOORS MANUFACTURER'S INSTALLATION INSTRUCTIONS AND 2018 UPC TABLES 313.3& Z PVC(TYPE DWV) 4 FT. 10 FT. WHERE THEY ARE NOT HIGHLY VISIBLE.FLOOR CLEANOUTS IN CARPETED 313.6.SUBMIT FOR APPROVAL. GRAVITY TANK-TYPE WATER CLOSETS 1.28 GALLONS/FLUSH 'CAST-IRON OVER 4'SHALL BE SUPPORTED AT EVERY JOINT AREAS TO BE FITTED WITH CARPET INSERTS.LOCATIONS SHALL BE SUBMITTED FLUSHOMETER TANK WATER CLOSETS 1.28 GALLONSIFLUSH FLUSHOMETER VALVE WATER CLOSETS 1.28 GALLONS/FLUSH TO ARCHITECT FOR E PLUMBING DRAWINGS.APPROVAL. OVAL.NOTE:NOT ALL CLEANOUTS ARE SHOWN ON 30. DIELECTRIC UNIONS:PROVIDE AT CONNECTIONS OF DISSIMILAR PIPE. OO�p o?C SOO 31. CONDENSATE DRAIN:PROVIDE A P-TRAP FOR EACH HVAC UNIT CONDENSATE ,O F, p ELECTROMECHANICAL HYDRAULIC WATER CLOSETS 1.28 GALLONS/FLUSH 6. SHUT-OFFS:PROVIDE 1/4 TURN BALL VALVE ANGLE STOP SHUT-OFF VALVES PAN WITH PLUG TEES FOR CLEANING.CONDENSATE DRAINS SHALL BE 00'�_.�!ol O URINALS,WALL MOUNTED 0.125 GALLONS/FLUSH AND BRAIDED STAINLESS STEEL FLEX CONNECTORS AT HOT AND COLD WATER DISCHARGED TO AN INDIRECT WASTE OR OUTSIDE. P O HANGER SPACING FOR SUPPLY TO EACH FIXTURE.EXCEPTION:PROVIDE SCREWDRIVER STOPS AT N URINALS,OTHER 0.5 GALLONS/FLUSH WATER PIPING BATH/SHOWERS. 32. PIPING&EQUIPMENT SUPPORTS/HANGERS&SEISMIC RESTRAINTS TO BE .p sri EO NOTES: DESIGNED BY DESIGN BUILT CONTRACTOR. 00 ....�" ALL SUSPENDED WATER SUPPLY PIPE SHALL BE SUPPORTED 7. TRAP ARMS:PROVIDE TRAP ARMS SUCH THAT THE MAXIMUM LENGTH WILL (1)WHEN A SHOWER IS SE VED B ONE OR MORE AND/OR SHOWER INCLUDING CONTROLLED BY A SINGLE VALVE AS FOLLOWS PER 2018 UPC TABLE 313.3: NOT EXCEED CODE REQUIREMENTS. 33. IF NEEDED,PROVIDE VACUUM BREAKERS AT ALL HOSE BIBBS. COMBINED FLOW RATE OOOp 11 5'23 SHALL NOT EXCEED 1.8 GPM @ 80 PSI. MAX.HORIZONTAL MAX.VERTICAL 8. ADA INSULATION:AT PLUMBING PIPING EXPOSED UNDER LAVATORIES, 34. FLOOR DRAINS OR SIMILAR TRAPS DIRECTLY CONNECTED TO THE DRAINAGE SPACING SPACING INSULATE THE EXPOSED PIPING AND TRAPS WITH PRODUCT SPECIFICALLY AND SUBJECT TO INFREQUENT USE SHALL BE PROVIDED WITH AN APPROVED (2)WHEN INSTALLED IN COMMON&PUBLIC USE AREAS(OUTSIDE OF DWELLINGS OR SLEEPING UNITS)IN COPPER PIPE<1 z" 6 FT. 10 FT. DESIGNED FOR THIS APPLICATION MEETING ADA REQUIREMENTS.PROVIDE AUTOMATIC MEANS OF MAINTAINING THEIR WATER SEALS IN ACCORDANCE RESIDENTIAL BUILDINGS,FLOW RATE SHALL NOT EXCEED 0.5 GPM @ 60 PSI COPPER PIPE>2" 10 FT. 10 FT. HANDI-LAV GUARD OR EQUIVALENT.OFFSET P-TRAPS TO CLEAR WHEELCHAIR WITH 2O18 UPC 1007.0. (3)LAVATORY FAUCETS LOCATED IN RESTROOMS INTENDED FOR USE BY THE GENERAL PUBLIC SHALL BE COPPER TUBING< 2" 6 FT. 10 FT. ACCESS. EQUIPPED WITH A SELF-CLOSING METERING VALVE WHEN LEFT UNATTENDED.EXCEPTION:WHERE DESIGNED AND COPPER TUBING>2" 10 FT. 10 FT. 35. INSULATION MATERIAL SHALL MEET CITY OF ARLINGTON QUALITY STANDARDS. INSTALLED FOR USE BY PERSONS WITH A DISABILITY.EXCEPTION:WHERE INSTALLED IN DAY CARE CENTERS,FOR CPVC<1" 3 FT. 10 FT. 9. GAS EQUIPMENT:GAS EQUIPMENT SHALL BE INSTALLED PER EQUIPMENT USE PRIMARILY BY CHILDREN UNDER 6 YEARS OF AGE. CPVC>14" 4 FT. 10 FT. LISTINGS,APPLICABLE IFGC,UPC,LOCAL CODES&NFPA STANDARDS. 36. ALL PIPING AND DUCTWORK SHALL BE INSULATED CONSISTENT WITH THE 2018 RO I O (4)EXCEPTION:CLINICAL SINKS,LAUNDRY TRAYS,SERVICE SINKS 10. GAS CONNECTIONS:INSTALL FLEXIBLE QUICK DISCONNECT ASSEMBLIES FOR WA STATE ENERGY CODE. 5 KITCHEN FAUCETS MAY TEMPORARILY INCREASE FLOW ABOVE THE MAXIMUM FLOW RATE,BUT NOT ABOVE 2.2 ALL GAS FIRED KITCHEN EQUIPMENT PER APPLICABLE IFGC,UPC,LOCAL 37. BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH 2O18 UPC ENGINEERING,INC O GPM @ 60 PSI AND MUST DEFAULT TO A MAXIMUM FLOW RATE OF 1.8 GPM @ 60 PSI.AERATORS OR OTHER MEANS CODES&NFPA STANDARDS.PROVIDE LOCKABLE GAS SHUT-OFF VALVES FOR 701.0 AND 903.0. iemiamBnvew,sa-20D,wa 96036 MAY BE USED TO ACHIEVE REDUCTION. FIREPLACES&BBQS IN UNATTENDED PUBLIC LOCATIONS IN THE BUILDING. 2063 343mti 38. ALL SANITARY SYSTEM MATERIAL SHALL BE LISTED BY AN APPROVED LISTING pn ac�r crrEeDreac2i"A (6)PRERINSE SPRAY VALVES SHALL BE EQUIPPED WITH AN INTEGRAL AUTOMATIC SHUTOFF. 11. GAS PIPING CONNECTIONS TO WATER HEATERS,BOILERS AND FURNACES AGENCY. SHALL HAVE DIRT LEGS AND UNIONS PROVIDED ON APPLIANCE SIDE OF SHUTOFF VALVE. 39. ALL STORAGE WATER HEATING EQUIPMENT SHALL BE PROVIDED WITH AN APPROVED,LISTED EXPANSION TANK OR OTHER DEVICE DESIGNED FOR 12. GAS PIPING INSTALLATION:STEEL OR MALLEABLE IRON FUEL LINES 2"OR INTERMITTENT OPERATION FOR THERMAL EXPANSION CONTROL PER 2018 UPC O O 0 SMALLER SHALL BE ASSEMBLED USING THREAD SEALANT SUITABLE FOR 608.3. NATURAL GAS.GAS PIPING LARGER THAN 2"SHALL HAVE WELDED FITTINGS. Y 40. WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST HORIZONTAL 13. GAS PIPING ABOVE GROUND:WHERE PASSING THROUGH AN OUTSIDE WALL, DISPLACEMENTS DUE TO SEISMIC MOTION PER 2018 UPC 507.2. o GAS PIPING SHALL BE PROTECTED AGAINST CORROSION BY COATING OR i U Y O WRAPPING WITH AN INERT MATERIAL.WHERE PIPING IS ENCASED IN A 41. MATERIAL EXPOSED WITHIN A DUCT OR PLENUM SHALL COMPLY WITH 20181MC O Q: PROTECTIVE PIPE SLEEVE,THE ANNULAR SPACE BETWEEN THE PIPING AND 602.2.1. w x a p p � 2018 WASHINGTON STATE PIPE INSULATION SCHEDULE THE SLEEVE SHALL BE SEALED. 42. HVAC EQUIPMENT AND WATER HEATERS SHALL COMPLY WITH 20181MC 14. GAS PIPE SUPPORT:FUEL LINES SHALL BE SUPPORTED OR STRAPPED,AND CHAPTER 3. SHALL BE PLUMB AND SQUARE. OPTION 1 OPTION 2 43. PLUMBING FIXTURES AND FITTINGS SHALL COMPLY WITH CITY OF ARLINGTON SERVICE VAPOR RETARDER NOTES 15. GAS PIPING SHALL NOT BE BURIED UNDER BUILDING,SLAB OR OTHER WATER CONSERVATION STANDARDS. REQUIRED STRUCTURE. MATERIAL THICKNESS MATERIAL THICKNESS 44. CONTRACTOR SHALL PROVIDE FIRESTOPPING AT PENETRATIONS AS 16. GAS PIPING PROTECTIVE COATING:PAINT ALL EXTERIOR EXPOSED GAS PIPING NECESSARY TO RETAIN THE FIRE RATING OF ALL ASSEMBLIES.ALL WORK DOMESTIC COLD WATER,IRRIGATION WATER,CONDENSATE DRAINS, WITH TWO COATS OF RUST INHIBITIVE PAINT.COLOR:GRAY. SHALL BE IN COMPLIANCE WITH CODE REQUIREMENTS FOR THE BUILDING STORM DRAIN(IN CONDITIONED SPACE) MINERAL-FIBER WITH JACKET ALL SIZES:Yi' PVC/NBR ALL SIZES:3/e" YES 8,9 CONSTRUCTION TYPE. 17. WATER HAMMER ARRESTORS:PROVIDE AT THE END OF HOT AND COLD WATER DOMESTIC COLD WATER,IRRIGATION WATER,CONDENSATE DRAINS, (R-3) (R-3) LINES SERVING TWO OR MORE FIXTURES;SIZE IN ACCORDANCE WITH 45. PLUMBING CONTRACTOR SHALL PROVIDE REDUCED PRESSURE BACKFLOW PLUMBING AND DRAINAGE INSTITUTE(PDI)REQUIREMENTS.WATER HAMMER PREVENTERS OR OTHER APPROVED BACKFLOW PREVENTION DEVICE WHERE WASTE(OUTSIDE THE CONDITIONED SPACE) MINERAL-FIBER WITH JACKET Y2"PIPE:Y2" PVC/NBR Y2"PIPE:Y2" YES 4.5,7 ARRESTORS ARE REQUIRED FOR QUICK CLOSING VALVES,SUCH AS LAUNDRY REQUIRED BY HEALTH AUTHORITIES,FOOD SERVICE DRAWINGS,APPLIANCE ALL OTHER SIZES:1" ALL OTHER SIZES:3/a" WASHERS,FLUSH VALVES(PUBLIC TOILETS),ETC. MANUFACTURER INSTRUCTIONS AND BY CODE. M W N DOMESTIC HOT WATER AND RECIRCULATED HOT WATER Y2"-1Y4 Y2"PIPE:1" "-1Y4"PIPE:1" 18. TRAP PRIMERS AS SPECIFIED:PROVIDE TRAP PRIMERS AND PIPING FOR FLOOR PROVIDE REQUIRED&PROPER BACK FLOW PREVENTERS AS SPECIFIED FOR U- N MINERAL-FIBER WITH JACKET PVC/NBR NO 3,6 00 (NONRESIDETIAL) 1Yz''-4"PIPE:1.5" 1Yi'-4"PIPE:1.5" DRAINS,FLOOR SINKS,AREA DRAINS&HUB DRAINS.ARRANGE PIPING TO THE APPLIANCES INCLUDING,BUT NOT LIMITED TO THE FOLLOWING: � 01 ACHIEVE EQUAL FLOW TO EACH DRAIN AND FLOOR SINK FOR TRAP PRIMERS EXPOSED SANITARY DRAINS AND DOMESTIC WATER SUPPLIES AND SERVING MULTIPLE DRAINS AND FLOOR SINKS.COORDINATE EXACT a. ICE MACHINES AND ICE MAKERS >Q m STOPS FOR ADA FIXTURES. TRUEBRO LAV-GUARD N/A N/A N/A NO 12 LOCATIONS WITH ARCHITECT&ELECTRICAL ENGINEER. b. CARBONATED BEVERAGE DISPENSING SYSTEMS U > H c. COFFEE BREWERS co NOTES: 19. P-TRAPS:ALL EXPOSED P-TRAPS SHALL BE CHROME-PLATED BRASS.P-TRAPS d. ESPRESSO MACHINES C45 N o SERVING HANDICAPPED COUNTER TOP LAVATORIES SHALL BE INSULATED. e. WATER FILTERS 0 m f. STEAM OR HOT WATER BOILERS } ¢3 1. SEE BELOW PLUMBING NOTES FOR APPLICABLE CODES. J a) 20. THROUGHOUT THE PROJECT PROVIDE BALL VALVES.GATE VALVES SHALL NOT g. IRRIGATION SYSTEM 2. PIPING INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FROM DAMAGE.CONTRACTOR SHALL PROVIDE SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL.ADHESIVE TAPE SHALL NOT BE BE USED.NO EXCEPTIONS. h. FIRE PROTECTION SYSTEM p o PERMITTED. L CHEMICAL TREATMENT SYSTEM w L 0`4 3. NOT USED. 21. HOT WATER RECIRCULATING BALANCING VALVES SHOULD BE BELL&GOSSETT j. SOAP/CHEMICAL DISPENSER SYSTEM Q Q o Z o CIRCUIT SETTER(WATTS OR EQUAL)WITH INTEGRAL READOUT PORTS, k. COMMERCIAL WASHER o z_ 4. PER 2018 SECTION E (NON-RESIDENTIAL). ADJUSTMENT KNOB,DRAIN CONNECTION,AND POSITIVE SHUTOFF. v I 0- ^�a 5. PIPING FROOMM W WATER HEATTERR T TO THE TERMINATION OF HEATED WATER SUPPLY PIPE SHALL BE INSULATED IN ACCORDANCE WITH TABLE C403.2.9. _ () 6. ON BOTH THE INLET AND OUTLET PIPING OF A STORAGE HOT WATER HEATER,THE FIRST 8 FEET OF PIPING OR PIPING FROM WATER HEATER TO HEAT TRAP SHALL BE INSULATED. 22. DISASSEMBLY PROVISIONS:PROVIDE UNIONS OR FLANGES AT PIPING J 9 z Z_ 7. HEAT TRACED PIPING SHALL BE INSULATED IN THE SAME MANNER AS NON HEAT TRACED PIPING OR PER HEAT TRACE MANUFACTURER SPEC. CONNECTIONS TO EQUIPMENT,COILS,TRAPS,CONTROL VALVES,AND OTHER L I( COMPONENTS TO ALLOW DISASSEMBLY FOR MAINTENANCE. O O 8. TUBULAR PIPING INSULATION SHALL NOT BE REQUIRED FOR THE FOLLOWING: :_ A. TUBING FROM FROM THE CONNECTION AT THE TERMINATION OF THE FIXTURE PIPING TO A PLUMBING FIXTURE SUPPLY PIPING TO A PLUMBING FIXTURE. (/� O IA Z' B. VALVES,PUMPS,STRAINERS AND THREADED UNIONS IN PIPING THAT IS 1 INCH OR LESS. Lf') {�/f C. PIPING FROM USER CONTROLLED SHOWER AND BATH MIXING VALVES TO THE WATER OUTLET. Q 0 ~~D. COLD WATER PIPING OF A DEMAND RETICULATION WATER SYSTEM m W W E. TUBING FROM A HOT DRINKING WATER UNIT TO THE WATER OUTLET. O Z F. PIPING AT LOCATION WHERE A VERTICAL SUPPORT OF PIPING IS INSTALLED. r G. PIPING SURROUNDED BY BUILDING INSULATION WITH R-VALUE OF NOT LESS THAN R-3. U w Z 9. PER 2018 UPC,SECTION 312.6 NO WATER,SOIL OR WASTE PIPE SHALL BE INSTALLED OR PERMITTED OUTSIDE OF THE BUILDING,IN ATTIC OR IN AN EXTERIOR WALL UNLESS ADEQUATE PROVISION IS MADE TO PROTECT SUCH PIPE FROM VJ FREEZING.ALL HOT AND COLD WATER PIPES OUTSIDE THE CONDITIONED SPACE SHALL BE INSULATED TO MINIMUM R-3. 10. HEAT TRACING SHALL BE PROVIDED FOR COLD WATER AND IRRIGATION WATER IN UNCONDITIONED SPACES.REFER TO HEAT TRACING SCHEDULE FOR DETAIL.CONTACT ENGINEERING IF NECESSARY.PER 2018 WSEC SECTION C403.2.4.6 TE: 11/15/2023 FREEZE PROTECTION SYSTEMS,SUCH AS HEAT TRACING OF OUTDOOR PIPING SHALL INCLUDE AUTOMATIC CONTROLS CONFIGURED TO SHUT OFF THE SYSTEM WHEN OUTDOOR AIR TEMPERATURES ARE ABOVE 40"F. 11. PER 2018 WSEC TABLE C403.2.9(FOR NON-RESIDENTIAL)INSULATION FOR HOT WATER AND HOT WATER RETICULATION SHALL HAVE CONDUCTIVITY OF 0.21-0.28(BTU.IN/H.FT'."F)AT OPERATING TEMPERATURE. 12. INSULATION R-VALUE SHALL MEET MINIMUM REQUIREMENT.THICKNESS IS BASED ON GRAINGER SAMPLE DATA FOR K-FLEX(PVC/NBR)AND OWENS CORNING(FIBER GLASS). SHEET TITLE: 13. ALL ADA P-TRAPS,HOT WATER SUPPLY TUBING AND SHUT-OFF COCKS SHALL BE PROTECTED WITH APPROVED COVERS TO PREVENT SCALDING. PLUMBING NOTES 14. REQUIRED BY ENGINEERING BASED ON BEST PRACTICE. AND TABLES 15. INSULATION IS NOT REQUIRED ON PLASTIC PIPING. SHEET NO. P0. 1 PLUMBING CALCULATIONS PLUMBING SCHEDULES FIXTURE UNIT CALCULATIONS CALCULATIONS BASED ON 2018 UPC APPENDIX A TABLE A103.1&CH.7 TABLE 702.1 FIXTURE UNITS LEVEL TOTAL CITY TOTAL FIXTURE UNITS FIXTURE OF FIXTURES TOTAL CW HW WN 1 SERVICE CW ONLY HW ONLY WN ONLY z WATER CLOSET FLUSH VALVE 5 5 0 4 2 2 10 10 0 8 a 0 PUBLIC LAVATORY 1 0.75 0.75 1 2 2 2 1.5 1.5 2 O w 2"FLOOR DRAIN 0 0 0 2 2 2 0 0 0 4 0 4"FLOOR SINK 0 0 0 8 6 6 0 0 0 48 MOP SINK 3 2.25 2.25 3 1 1 3 2.25 2.25 3 HAND SINK 1 0.75 0.75 1 2 2 2 1.5 1.5 2 0 DUMP SINK 1 0.75 0.75 0 1 1 1 0.75 0.75 0 3-COMP SINK 3 2.25 2.25 0 1 1 3 2.25 2.25 0 DISHWASHER 3 3 0 0 1 1 3 3 0 0 Z 1-COMP SNK 1.5 1.125 1.125 0 1 1 1.5 1.125 1.125 0 PIPE MATERIALS SCHEDULE COMBIOVEN 1 1 0 0 1 1 1 1 0 0 PIPE TYPE MATERIAL JOINT NOTES Opp000ppp GLASS RINSER 1 1 0 0 1 1 1 1 0 0 00 C WATER FILTRATION SYSTEM 1 1 0 0 3 3 3 3 0 0 O J A ks Q, UNDERGROUND WATER DISTRIBUTION PIPING PEX SOLDERED,WELDED,OR PROPRESS (2) SUBTOTAL 30.5 27.375 9.375 67 P p ABOVE GROUND WATER DISTRIBUTION PIPING PEX SOLDERED,WELDED,OR PROPRESS O TOTAL CW MH� WN UNDERGROUND WASTE AND VENT PIPING SCHEDULE 40 PVC OR ABS SOLVENT CEMENT TOTAL FIXTURE UNITS: 30.5 27.375 67 OOp Sg/CN ABOVE GROUND WASTE AND VENT PIPING CAST IRON WASTE WITH ABS VENTS SOLVENT CEMENT OR HUBLESS COUPLINGS (3) PEAK FLOW: 20 GPM ppoD 11,E 5,23 REQUIRED SERVICE SIZE IN BUILDING: (1)1 1/4" (1)4" CONDENSATE DRAIN PIPING COPPER,TYPE M OR CPVC SOLDERED OR SOLVENT CEMENT GREASE INTERCEPTOR CALCULATIONS NATURAL GAS PIPING STEEL PIPE,ASTM A 53:TYPE E OR S;GRADE B;SCHEDULE 40 THREADED,WELDED,OR MEGAPRESS NOTES: CALCULATIONS BASED ON 2018 UPC (1)ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN APPROVED LISTING AGENCY. FIXTURE QUANTITY L W D CU IN. GALLONS FLOW RATE (2)PLASTIC WRAP UNDERGROUND WATER SUPPLY PIPING TO PREVENT CORROSION. OBI SON HAND SINK 2 14 10 10 2633 11 4 ENGINEERING,INC MOPSINK 1 20 16 6 1920 8 3 iswiam-w,.-2 LYNNWO0OWA96036 3-COMP SINK 1 18 18 14 13608 59 22 FEI PFOhC�20636bN30 E36 ..962L26 1-COMP SINK 1 18 18 14 4536 20 7 DUMP SINK 1 14 10 10 1400 6 2 DISHWASHER 1 N/A N/A N/A - - 29 2"FLOOR DRAIN 2 N/A N/A N/A - - 0 PLUMBING FIXTURE SCHEDULE o 0 0 0 4"FLOOR SINK 6 N/A N/A N/A - - 6 Y SERVICE SIZE-INCHES TOTAL FIXTURE FLOW RATE(GPM) 74 PLAN MARK FIXTURE TYPE LOCATION FINISH MANUFACTURERS BASIS OF DESIGN NOTES o CW HW W V Z y O PIPE SIZING FOR PEX PIPE AT 2 PSI/100' WITH HUNTER'S CURVE- FLUSH TANK SIZING WC-1 WATER CLOSET 3/4" 3" 2" PEP�FLNSOR TBD TBD TBD w O U Q 52°COLD WATER 120°HOT WATER 116°RECIRUCLATED LAV-1 FAUCET Y,' )/2" - - PER FLOOR PLANS TBD TBD TBD - WSFU GPM FT/S WSFU GPM FT/S GPM FT/S PER FLOOR LAVATORY - - 2" 1Yz" PLANS TBD TBD TBD - 0.0 1.0 1.8 0.1 1.1 2.0 1.1 2.0 Y" 1.5 2.5 2.3 1.9 2.9 2.6 2.2 2.0 FCO-1 CLEANOUT - - - - NOTE 1 IRON/BRASS WATTS CO-260 8"GASKET 1" 6.0 5.0 2.8 6.6 5.6 3.1 3.6 2.0 1%" 11.3 8.7 3.2 12.7 9.7 3.6 5.4 2.0 NOTES: 1 Y." 19.1 13.5 3.6 21.9 15.1 4.0 7.6 2.0 (1)CONTRACTOR TO INSTALL AS REQUIRED BY CODE 2" 47.6 28.0 4.3 55.4 31.2 4.8 13.0 2.0 2 Y." 121.5 49.3 5.0 122.3 49.5 5.0 19.8 2.0i-- M 3" 271.6 79.3 6.6 227.6 70.6 5.0 28.2 2.0 W N u- OD 01 PRESSURE CALCULATION DRAIN SCHEDULE U CALCULATION BASED ON 2018 UPC APPENDIX A H SERVICE SIZE m ro MINIMUM PRESSURE AT BACKFLOW PREVENTOR,PSI 45 N o EQUIP NO. LOCATION FIXTURE TYPE FINISH MANUFACTUER BASIS OF DESIGN NOTES O6 PER BACKFLOW ASSEMBLY TEST REPORT,05/09/23 W V w a d FS-1 PER FLOOR PLANS NOTE 2 NOTE 2 FLOOR SINK N/A JAY R.SMITH 310Y (3) o J C x d PIPING FRICTION LOSSES w L 00 FD-1 PER FLOOR PLANS NOTE 2 NOTE 2 FLOOR DRAIN NICKEL BRONZE SIOUX CHIEF 833 (3) Q Q 3 w PIPING SYSTEM LENGTH,FEET 250 Z O rn a FITTING ALLOWANCE,FEET 62.5 NOTES: _ V FROM BACKFLOW TO FURTHEST FIXTURE (1)CONTRACTOR SHALL CONFIRM MAKE,MOOEL,AND FINISH OF ALL FIXTURES WITH OWNER,ARCHITECT,AND INTERIOR DESIGNER PRIOR TO ORDERING. J Q Z Z (2)SIZE PER PLANS ZONE FRICTION LOSS FACTOR,PSI/100' 2.0 (3)INSTALL FLUSH WITH FINISHED FLOOR. O {jI ) Z TOTAL ZONE FRICTION LOSS,PSI 6.25 Q "-y re w � MINIMUM PRESSURE AT FURTHEST FIXTURE,PSI mW 38.8 �l.� Z HOT WATER HEATER CALCS W - 1) HOURLY HOT WATER DEMAND TABLE(GPH) Z HAND SINK 6 GALLONS PER SINK W MOP SINK 8 GALLONS PER SINK 3-COMP SINK 20 GALLONS PER COMPARTMENT 1-COMP SINK 20 GALLONS PER COMPARTMENT TE: 11�15�2023 DUMP SINK 6 GALLONS PER SINK PUBLIC LAVATORY 5 GALLONS PER LAVATORY SHEET TITLE: 2) FIXTURE QUANTITY GPH TOTAL GPH REQ'D PLUMBING HAND SINK 2 6 12 MOP SINK 1 8 8 CALCULATIONS& 3-COMP SINK 1 60 60 t HEDULES 1-COMP SINK 1 20 20 DUMP SINK 1 6 6 PUBLIC LAVATORY 2 5 10 TOTAL 116 3) WATER HEATER SIZE CALCULATION: SHEET N0. 1 INSTANTANEOUS WATER HEATER PROVIDED,CAPABLE OF PROVIDING 288 GPH @ 68°F RISE. ^O.^ PLUMBING EQUIPMENT SCHEDULES WATER HEATER HEATEXCHANGER INLET/OUTLET GAS OPERATING EQUIP NO. SERVICE FUEL THERMAL GPH RECOVERYAT WEIGHT ELECTRICAL BASIS OF DESIGN NOTES z N SOURCE INPUT(MBH) EFFICIENCY 68°F CONNECTION CONNECTION (LBS) 0 F z 0 a � > U W WH-1 HOT WATER NAT.GAS 199.9 0.82 288 3/4" 3/4" 60 120VAC,MAX 2 wAMPS NORITZ NC199DVC 1 p NOTES: (1)PROVIDE CONCENTRIC VENT KIT p (2)INSTALL IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS. (3)ALL DOMESTIC WATER EQUIPMENT SHALL BE NSF-61 LISTED. O Z HOT WATER CIRCULATION PUMP 0000❑❑Ac E 000 ELECTRICAL A �p NO PRESSURE WEIGHT, pO�v:'pvaas SERVICE TYPE FLOW,GPM HEAD,FT PUMP RPM BASIS OF DESIGN NOTES NO. RATING,PSI LBS O P ❑❑ VOLTAGE HP ❑ h O HWCP-1 HOT WATER RECIRCULATION INLINE 1 5 1474 150 115V/iP - 7 BELL&GOSSETT-ECOCIRC 19-16 1 oo��Sso�oao �3 NOTES: (1)ALL BRONZE,MAINTENANCE FREE,SUITABLE FOR POTABLE WATER APPLICATION. (2)INSTALL IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS. (3)ALL DOMESTIC WATER EQUIPMENT SHALL BE NSF-61 LISTED. EXPANSION TANK ROBISON TANK SIZE ENGINEERING,INC OPERATING WEIGHT isnoiamHnvew,6ni—2 EQUIP NO. SERVICE CAPACITY(GAL) BASIS OF DESIGN NOTES LPNNW 0 WA9B036 DIAMETER(INCHES) HEIGHT(INCHES) (LBS) 206-3E3- FEI -NO..96- ET-1 DOMESTIC HOT WATER 2 8 13 281 AMTROL ST-5 1,2 NOTES: z z 0 (1)INSTALL IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS. O 0 0 (2)ALL DOMESTIC WATER EQUIPMENT SHALL BE NSF-61 LISTED. Y o z TRAP PRIMER ui w U w =<Ea p O U ¢ EQUIP SERVICE INLET/OUTLET CONNECTION DIMENSIONS(D"x H") BASIS OF DESIGN NOTES NO. TP-1 FLOOR DRAINS Y2"/Y2" 1%"x43%" PRECISION PLUMBING PRODUCTS MP-500-115V 1 NOTES: (1)NSF-61 COMPLIANT GREASE INTERCEPTOR M EQUIP NO. SERVICE FLOW RATE(GPM) GREASE CAPACITY LIQUIDS CAPACITY WEIGHT(LBS) CONNECTION BASIS OF DESIGN NOTES w CV (LBS) (GAL) SIZE 00 GI-1 GREASE WASTE 75 175 40 404 4" SCHIER GB-3 1,2,3 Q CT Q N > O NOTES: > w F (1)INSTALL IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS. (2)OR EQUIVALENTLY APPROVED. (3)PROVIDE SCHIER SV10 SAMPLING PORT. _C'6 O W J a3M C xdl REDUCED PRESSURE BACKF Z ZLOW ASSEMBLY Q z o EQUIP NO. SERVICE INLET/OUTLET SIZE BASIS OF DESIGN NOTES V Z Zz RPBP-1 DISHWASHER Y2"1Y2" ZURN WILKINS 375XLB 1,2 O O RPBP-2,3,4 WATER FILTER SYSTEM Y2"1Y2" ZURN WILKINS 375XLB 1,2 Q U) Z NOTES: {/�'Jy/~~f�J (1)MEETS AWWA C551-92 STANDARDS. w O W (2)ALL DOMESTIC WATER EQUIPMENT SHALL BE NSF-61 LISTED. r O w GAS PRESSURE REGULATOR9 Z w EQUIP NO. SERVICE MAX INLET MIN INLET OUTLET PRESSURE CAPACITY(MBH) MAX INDIVIDUAL LOAD ORIFICE SIZE BASIS OF DESIGN NOTES TE: 11/15/2023 PRESSURE PRESSURE (MBH) GPRV-1 PER PLANS 2 PSI 1 PSI T'WC 500 425 1" MAXITROL 325-5L 1,2 SHEET TITLE: PLUMBING NOTES: SCHEDULES (1)PROVIDE APPROVED VENT LIMITING DEVICE OR VENT TO EXTERIOR SIZED TO MATCH VENT CONNECTION ON REGULATOR.VENTS ARE NOT SHOWN ON THE PLANS. (2)STEPDOWN REGULATORS MUST BE AT 4 FEET AFF. SHEET NO. P0.3 Z 0 O F ap D) > N W w � SHEET NOTES: 1. Waste&Vent Sizing:waste&vent piping sized per 2018 d 5 16.7 7 17.5 8 UPC Table 703.2.Piping 4"and larger shall be sloped atY8" Z per foot with approval of AHJ.Piping smaller than 4"shall be sloped at Y4"per foot: boo°�o Ae s°o� peviasy PIPE SIZE VERT. HORIZ. VENT 1y2'' 2 FU 1 FU 8 FU J'___FF 2" 16 FU 8 FU 24DFU C 3" 48 FU 35 FU 84 FU °°ossi 4" 256 FU 172 FU 256 FU °pOoao 15 23 i 9� 6rvEL�ND ° „ oFsr RE,A6E 6rvEL�rv� ORDER � 6" 1,380 FU 576 FU 1,380 FU 11� TRA6H 8" 3,600 FU 2,112 FU 3,600 FU DINING IF ROOM 2. Provide floor and wall cleanouts as required by code. DELI 2'G O.°w 3. Provide trap primers for all floor drains per 2018 UPC 1007.1.G ROBISON = - a.. V_GW See Detail 2/P6.0. ENGINEERING,INC 3"GW ( V3 i9wi mrDAvew,.1— LYNNWOOD,WA96036 FLAG NOTES: D636633E3 n pE - ___3"G FNIT JECN0.:962L29 W G GW I VYI 1. 4"SS point of connection to existing sanitary sewer. a"s 2. WC-1 underslab waste piping.Architect to verify fixture z z za°ss 0 0 0 v2° location. c 3. GI-1 sample box. Y D 1v2"v 3„ b d� G z V D PICK-UP 3 W GW2„GW z3 X O (37 3 °. o---_ 3�VJ M —o W =U Ld a � O Q EE1/'vI 3 � o GI-1 S-C L LOUNGE 3 O �i OU F GW 4 G G - 2 07 O 3"SS I 3' 3"SS LL 00 (ARC IV TO .a O` FDRY FY) FY) STORAGE F N 5 U 3 0 unnnn courvrea 2"SS o `iV 0 rn m t Q G J � a3ccOn C xd� w Q 800 w oZz � o � rn�a Z Zz � 0 0 _ z_ 5 7 8 Q o -- W 04 m LO W 0 z z W TE: 11/15/2023 SHEET TITLE: UNDERSLAB WASTE &VENT PLAN UNDERSLAB WASTE&VENT PLAN ( Y SCALE:1/4"-1'-0" J SHEET NO. P2.0 Z 0 O F ap D) 5 N W w � SHEET NOTES: 1. Waste&Vent Sizing:waste&vent piping sized per 2018 z 5 16.7 7 17.5 8 UPC Table 703.2.Piping 4"and larger shall be sloped atY8" per foot with approval of AHJ.Piping smaller than 4"shall be poopp sloped at Y4"per foot: oo�o J AC soo PIPE SIZE VERT. HORIZ. VENT o 1Y2" 2 FU 1 FU 8 FU JE7 2" 16 FU 8 FU 24DFU ooR s„ Eo C 3" 48 FU 35 FU 84 FU 4" 256 FU 172 FU 256 FU °000pp 15 23 i 9 EL IrvD ° „ oFsr RE,a6E ELVIrv" ORDER a 6" 1,380 FU 576 FU 1,380 FU 11 �6ry 3"FS-1 F 8" 3,600 FU 2,112 FU 3,600 FU DINING > I ROOM ' 2. Provide floor and wall cleanouts as required by code. DFrLOD- __� 1/2° 3. Provide trap primers for all floor drains per 2018 UPC 1007.1. ROBISON ---- — See Detail 2/P6.0. __S6_sa_a ENGINEERING,INC � 3/a'CD i9noiamDnvEw,wrtE3c 1Y"V a LYNNWOOD T 0 ^ 20636b33E3�36 %"Co CD — 1 'V FLAG NOTES: P 2L26 L , FEI0.:96 CO-T I ��3(a6D „ �I K 3 ES_i 1. Existing 4"V to roof. �I �s 2. Walk-in cooler evaporator.Equipment shown for reference z z PREPN only. 0 0 0 0 ' COOK 3. Walk-in freezer evaporator.Equipment shown for reference Y 2"FD-1 only. n 4. 2"V;wet vent for WC-1.Architect to verify fixture location. Z Y 'o PICK-UP 1Vv 31. 5. 2"V for WC-1.Architect to verify fixture location. < W = a O 3'V 1 ,7 3°F_°o 7 LOJ I 6. GI-1 pedestrian rated cover. 0 0 0 a 7. FC sample box cover. r--1 � 8. FCU-1.Mechanical equipment shown for reference only.See I s mechanical plans for more detail. SC 9. FCU-2.Mechanical equipment shown for reference only.See tans for more detail. ?I L--J LOUNGE [" mechanical p in l 3 10. Provide 5 "Nortiz concentric stainless steel pipe to outdoors. - I � Terminate with required clearances to operable windows, O I a 2,v— __1Y2" _ doors and OSA intakes. UOD I � - WG1 I i WC-1 Cl) EN'S I WOMEN' s o w04 (ARCH TO I (AR TO IpRAGE < CD Q < F UC n nV RIFY) I VERS1`H) F Q O m courvrea T Qx m 0 v V O i�E� rnm t Q G J c =o� D LJJ 800 Q 3:6' IO pZZ 0 V) d rn E Z D Zz � 0 0 _ z_ 5 7 8 Q o 0 0 W c`nv m W W O Z W TE: 11/15/2023 SHEET TITLE: LEVEL 1 WASTE& VENT PLAN LEVEL 1 WASTE &VENT PLAN SCALE'.1/4"-V-0" ` SHEET NO. 1 SHEET NOTES: 1. Provide expansion loops for all water piping per the manufacturer's instructions.See Detail 2/P6.0. z 0 F 0 2. Provide trap primers for all floor drains per 2018 UPC 1007.1. a See Detail 5/P6.0. w 0 0 5 (6.7 7 17 5 8 Z °ppOopp�p 00 J A C °oQ F,o...._..._kS, `b of �, ... C3 T--FF °o p sn Eo C ooOossia� g 6 d E N� osPar E E N� ORDER �o0 11 15 23 II (FUTURE)A6 u RA6N DINING IF ROOM 3%-cw DELI A' TP1 ROBDSON ENGINEERING,INC sno,amHnvew,wrtE3cz 36"cw 200-3E3� KITCHEN PREP/ 0 0 0 0 �r COOK Y V3 D Cw Do O PICK-UP M w a U O SCULLERY LOUNGE -7 TE, I �� O . O O M O wN EN'S WOMEN'S DRY LL ONO (ARCH TO (ARCH TO STORAGE 01 F VERIFY) VERIFY) OFQ UC In In In n U < F COUNTER N Ell 0 kWWI o M ?rnm t Q G J a3M C 0 0 o Q LU Q o()o w pzzo� rn a Z Z z � 0 0 _ z_ 5 7 8 Q o I--I rX LU C`NN m W W Oz z W VTE: 11/15/2023 SHEET TITLE: UNDERSLAB SUPPLY PLAN UNDERSLAB SUPPLY PLAN (OY� SCALE:1/4"-V-0" J SHEET NO. P3.0 SHEET NOTES: 1. Provide expansion loops for all water piping per the manufacturer's instructions.See Detail 2/P6.0. Z o F p 2. Provide trap primers for all floor drains per 2018 UPC 1007.1. See Detail 5/P6.0. w 0 3. Provide MV-1 thermostatic mixing valves and set to 120T in all public lavatories and kitchen handwashing sinks.See Detail H 7/P6.0. 4. Provide vents to outdoors for regulators per local jurisdiction o 5 16.7 7 (7.5 8 and NFPA-54.Routing of vents is not shown on the plans. Z 5. Mount Reduced Pressure Backflow Preventers where o 10 Ac accessible for testing' ° ,ee�uasy� FLAG NOTES: o C 1. 2"CW point of connection from existing water meter. °000sy d' 2. Provide RPBP-1 on CW line to dishwasher. °p❑❑❑❑ 15,23 i 9 d EL°Iry osPa° E EL Irv„ 4 ORDER 3. Provide RPBP-2 on CW line to water filtersystem. 11' � T— , 4. Provide RPBP-3 on CW line to water filter system. DINING _ ::�l 5. Provide RPBP-4 on CW line to water filter system. ROOM 6. 3/4"CW line for WC-1.Architect to verify fixture location. DELI 3 :; u; 7. Provide GPRV-1 pressure regulator set to 7"WC outlet cW pressure,vented to exterior. e — _' 1"cW 8. %z"MPG point of connection from existing gas meter. ROBISON Y4"CW A; 1„CW ENGINEERING,INC ,9w,4or„n wrt "CW LYNNWD—31 96036 20636b3343- 4"HW —NO CO— .. 1-CW - 111cw- - L—__—� 1%4''CW 3" PREP/ 0 0 0 � COOK Y D ,ti.. D PICK-UP 4 Hw...,., c Y o U O ::�:• U 3 - w = a EE 'HW 4"HW Y"CW 3/4"CW-4 HW SCULLERY LOUNGE 9 � T p'CW .. Yz"H ... O — "HW UOD ,i'HWC 1 - 1"CW � 1Y Hw � M 3/4„HW g w (y IFI "Hw 00 VERIFY) 4"G — p.EMS z„ON 00 ( CH TO LL F 1"Cw /4"HW UC n n n U m �w _ C w m M couNTER __ �- NEI (� O zM � wad G J a3M 8 7 LU L 0 0 o Q Q w �Z Z O � rn�a Z Zz � 0 0 _ z 5 7 8 Q o "--o E LU c`nv m W W 0 tI z W TE: 11/15/2023 SHEET TITLE: LEVEL SUPPLY PLAN LEVEL 1 SUPPLY PLAN ( 11 SCALE:1/4"=V-0" J SHEET NO. P3. 1 SHEET NOTES: 1. Provide expansion loops for all water piping per the manufacturer's instructions.See Detail 2/P6.0. 2. Provide trap primers for all floor drains per 2018 UPC 1007.1. ROOF See Detail 5/P6.0. 1"HW(3.38 FU) O Z 1yeCW(8.38 FU) 3. Provide MV-1 thermostatic mixing valves and set to 120°F in EL 2 1Ya"CW(9.5 FU) all public lavatories and kitchen handwashing sinks.See I W 1-CW(3.75 FU) 2"CWFU) N 1"CW(1.75 FU) 1"CW(4.5 FU) 1Ya"CW(6.5 FU) 1Ya"CW(7.25 FU) 1Ya'"CW(10.63 FU)1Y2"CW(13.63 FU) 2"CW(20.88 FU) 2"CW(25 FU) 2"CW(30.25 FU) Detail 7/P6.0. o - - -f'CW(2 FU) 3%"CW(1.13 FU� - - - - - - W(7.25 FU) - - 1 CW(5.75 FU) _ 1Ya"CW(9.38 FU) 1 FLAG NOTES: F1"HW(2.25 FU) 1'HW(4.5 FU) - - LL %a'"HW(0.75 FU) 3%a"HW(1.5 FU) � 1"HW(5.63 FU 1Y<"HW 7.88 FU) T3/a_HW(1_5 FU) _ __ 1. EXISYIng Z"CW line O__ _ -__--__ -__ 3 Y2_Hwc - HWCP-1 �rYz'Hwc� 2. Provide RPBP-1 on CW line to dishwasher. 3. Provide RPBP-2 on CW line to water filter system. z > j %"CW(1 FU)) LL LL LL LL 1"cw(3 Fu) 7 Y2"Hwc 4. Provide RPBP-3 on CW line to water filter system. N LL N LL LL M �2 m 3 0 0 o o 5. Provide RPBP-4 on CW line to water filter system. oFo❑❑❑�o V JA /,0OQ > op..... S z 1n 'x U x O evaas o b❑ N tV U P ❑ sn WATER WATERLIMP FILTER SINK RINSER FILTER HAND FILTER COMBI HAND 1-COMP 3-COMP 3-COMP DISH LAV LAV 0000Ospp�p `,j SYSTEM SYSTEM U SINK SYSTEM OVEN SINK SINK SINK SINK WASHER 11�15�2 LL � WH-1 Mo / 5 U 3%'CW(1 FU) / Yz"CW SINK WC t FLOOR 1 -T- T __w TP-1 TP-1 - 1"CW(2FU) RoBRSON ENGINEEING,INC i mrHnvew,s 1-2 LYNNWO0OWA96036 20636b33E3�n FEI PFOhQ`9C=" AD CONT UNDERSLAB O O 0 Y � SUPPLY DIAGRAM Z Y o U � w = a � O U Q a"v(saFu) ROOF SHEET NOTES: 2"V(14 FU) 3"V(84 FU) 2"V(7 FU) 2"V(13 FU) 3"V(79 FU) 3"V 30 FU 2"V(14 FU) 1. Waste&Vent Sizing:waste&vent piping sized per 2018 -- 3"V(73 FU) ( ) 2"V(21 Fu) 2"V(15 FU) UPC Table 703.2.Piping 4"and larger shall be sloped at r 2"V(5 FU) ----J__ 2"v�2zFuj------ - ----i- 3' ------------------------------------� per foot with approval ofAHJ.Piping smaller than 4"shall be ---- I I I V(79 FU) 1 "1Y2V(a FU) sloped at/a per foot: T-- T ----- T -- - -------T-------� I I I I 1 3"V(28 FU) I I I I I IL I L--- - ------ PIPE SIZE VERT. HORIZ. VENT L----_I-----1 1Y2"V(1FU) - ____I________I____I____I____I____I________I________I________ , I 1 �� 1Yz'v(1 Fu) I --I--------------------I----1----I--------I--------I--------1 I I 1/z 2 FU 1 FU 8 FU w N ----I____I--------I---J I I I I I 1 I I 2" 16 FU 8 FU 24DFU N -------------------I-----1--------1 I 1 1 I I I I I I ll co I �--------I---------------__I____I________I_______-I---J 3" 48 FU 35 FU 84 FU 4" 256 FU 172 FU 256 FU Q a Q o I I I I I I I LL I SI 6" 1,380 FU 576 FU 1,380 FU U 3 w I 1/2w(1 Fu) I 1 I I I SI LL 1 I I 8" 3,600 FU 2,112 FU 3,600 FU c N m"I �y I LLI LLI LLI �I �I >1 ?I >1 I I LL LL LL �I �I �I �I � a1 lVI 06 O W�L LL M 1 LLI >I I I I I I 2. Provide floor and wall cleanouts as required b code. a 3 I _ 1 4 Y HAND HAND v > > m a I �I I I I F o SINK SINK I ? I I I I I I wi 0 0 N 1 I I I I j I I 3. Provide trap primers for all floor drains per 2018 UPC 1007.1. Q o Z z 1 I I I I I I See Detail 5/P6.0. C m 1 I I I I I I '^ EL SINK I I I I I MopW FLOOR 1 ^ V7 1 3"FS-1 1 3"FS-1 1 2"FD-1 1 3"FS-1 1 3"FS-1 1 3"FS-1 1 2"FDA I 3"FS-1 FLAG NOTES: Z Z z 1 L L L I I I L 1 LL LL L I L L L L 00 1. Existing 4"V to roof. O 9) 1 S 2. Existing 4"SS to existing P.O.C. Vl Z 1 S S LL N S Q O ~/� 1 � �3 D3 LL3 _ LO IM W TV 43 FU soU soU c0 `-C7 �O -t7 LL LL w N W 2"SS(2 FU) <yt.�3"GW(8 FU) a a N W Z GI-1 4"GWG43 FU) 4"GW 40 FU) 3"GW 34 FU 3"GW 28 FU)�3"GWG�y W GW yy W 4"SS(45 FU) ( ) (20 FU) 3"GW4 FU) 3"GW(8 FU) 3"GW FU) 2 4"SS(55 FU) 1SS(43 FU) TE: 11/15/2023 3"SS(10 FU) 3"SS(6 FU) 3"SS(5 FU) SHEET TITLE: WASTE&SUPPLY DIAGRAMS UNDERSLAB SHEET NO. WASTE DIAGRAM P4.0 CONDENSATE DRAIN THROUGH-SLAB LAVATORY OR SINK PENETRATION SLEEVE OR WRAP F O_ PIPING TO PROTECT AGAINST BREAKAGE a CONCRETE FLOOR PER CODE HOT(i4p N w OR WALL TEE WITH SLIP JOIN ° °BY MECHANICAL CONTRACTOR COLD o FIXT.TAIL PIECE P-TRAP O Z WASTE THERMOSTATIC MIXING VALVE MAXIMUM ALLOWABLE PIPE LENGTH TO COMPLY WITH ASSE 1017 WALL BETWEEN FIXTURE AND HOT WATER PER WSEC TABLE C404.3.1 OOOOao ACO000Q, 0 02 ��eP`x^sy�: 0 °o p sn Eo CONDENSATE DRAIN TERMINATION PIPE SLAB PENETRATION A THERMOSTATIC MIXING VALVE 0D❑ °o�ssi SCALE:NONE V SCALE:NONE V SCALE:NONE • O 1"/�J CONNECT ABOVE CENTERLINE OF MAIN R O B I S O`'V■ 112" ENGINEERING,INC ,ew,amHavew,so—2 UNION WITHIN 12" Lvrvrvw000,wassoes BALL VALVE 20636b33E3n WATER TEST PORT MUST BE A MINIMUM DISTANCE OF REGULATOR pn a T 1rrEeorrosc_sreA PIPING—, OF 10X THE PIPE DIAMETER DOWNSTREAM MOUNT TRAP PRIMER OF THE REGULATOR GAS SUPPLY VALVE 12"FOR EVERY INSULATE PIPING TEST PORT TEST PORT Z z Q AS SHOWN IN SPECS 20'OF FOR LINE � O O BALL VALVE ABOVE Y 13 CEILING-SEE PLANS PPP MODEL PR-500 — FOR LOCATION. TRAP PRIMER VALVE o Z 0 1/2"GRAVITY TRAP O PROVIDE 8"x 8" PRIMER LINE CI Q v, w a ACCESS PANEL O U WHEN IN GYP. FLOOR DRAIN BOARD CEILING 6"MAX. L TO APPLIANCE I I ..... 3 SHUTOFF VALVES CEILING I I SLOPE TRAP ( ( J r PRIMER LINE P-TRAP SEDIMENTTRAP (") LU CV TYPICAL VALVE LOCATION FLOOR DRAIN AND TRAP PRIMER ^r� GAS PRESSURE REGULATOR IL a SCALE:NONE 6 SCALE:NONE V SCALE:NONE U3 oZf ° Wo m WALL "OFFSET'CONFIGURATION TERMINATE SLEEVE FLUSH WITH PIPE SLEEVE OF SIZE TO J x d PROVIDE STANDOFF FINISHED WALL SURFACE PASS PIPE AND INSULATION — MOUNTED TO WALL , (IF APPLICABLE)WITH MIN d" W i p o b x"L" ANNULAR SPACE Q Q �Z DRAIN 45° 777- CUT END D_ °' a HANGER OR GUIDE PIPE AND INSULATION f V FLOOR SINK jx"L" (IFAPPLICABLE) ` "JI Z REFER TO SPECIFICATIONS HANGER OR GUIDE CENTERED IN SLEEVE FINISHED ESCUTCHEON PLATE Z 1"MINIMUM PIPE AIR GAP FLUSH AGAINST WALL AND /\ FIRESTOP SLEEVE AT FLOOR FIRE-RATED WALLS OF SIZE TO COMPLETELY {rlr///f\ }x"L" COVER OPENING O Z CONCEALED PIPING PIPING EXPOSED TO VIEW a a.-. a INTERIOR WALLS 0 ~~ �' •_a • a a "LOOP"CONFIGURATION "CORNER"CONFIGURATION GALV STEEL PIPE SLEEVE COLLLA FOR CONCRET AND E LC140 W RESTRAINT OF SIZE TO PASS PIPE WALLS O Z S AND INSULATION WITH SEAL ENDS OF SLEEVE WITH U U' MIN d"ANNULAR SPACE w —� �—EXPANDING FOAM WEATHER- Z TIGHT SEALANT w LONG RUN OF PIPE "L" sx s x"L"MIN,TYP. PIPE AND INSULATION TE: 11/15/2023 (IF APPLICABLE) 'P'TRAP CENTERED IN SLEEVE sx"L" HANGERORGUIDE SHEET TITLE: COAT EXTERIOR SURFACES DETAILS HANGER OR GUIDE OUTDOOR INDOOR OF SLEEVE WITH COAL TAR EXTERIOR CONCRETE WALLS INDIRECT DRAIN TO FLOOR SINK 3 EXPANSION LOOP CONFIGURATIONS 2 PIPE SLEEVES THROUGH WALLS SHEET No. SCALE:NONE SCALE:NONE SCALE:NONE P6.0 Z N O F a0 D > N W w K O Z °pppopp°O °O J A °o NOT USED $ NOT USED 7 NOT USED 6 °OO°o op 15 2g SCAT F.NO- SLHLE:NONE S—E:NONE RoBiSON ENGINEERING,INC isADi amDAvew,wrt LYNNWOOD,WA96036 20636b33E3n FEI PFOJEC�N0.:962L29 0 0 0 0 Y � !J Z U U � w = a O U Q M LU N NOT USED ^r� NOT USED NOT USED ( LL- 00 S—E:NONE V S—E:NONE SLILLE:NONE V < 01 U 3 "6 O ?0 WATER HEATER VENT j¢ J ¢3M C =d10 "CLEANOUT"TO BE CAST 0 LLI i O 0 o 6"THICK BY 18" IN COVER CAST IRON CLEANOUT Q Q v Z SQUARE CONCRETE WITH COVER FOR ¢ Q o Z O PAD CAST IRON CLEANOUT MAY EXTEND AS APPLICABLE DUTY �3 rn _ -�a APPLICABLE DUTY WASTE OR VENT V FINISHED ��I V GRADE OR PAVING WALL FLOOR Z Q / ZI WITH COVER FOR PRESSURE&TEMP.RELIEF VALVE ll E O�� �jj�� (ROUTE TO NEAREST INDIRECT DRAIN) O � I-III-I I Imo-III-III- (' CHROME WALL COVER SHUTOFF VALVE JER �_ O Lo Z_AND SCREW AT FINISH CAST IRON EXTENSION- Q � �yAREAS ONLY SAME AS DRAIN SIZE MCAST IRON LONG SWEEP CAST IRON LONG SWEEP UP TO 4"DIAMETER ui CVitW 1/4BENDOR CAST IRON PLUGGED TEE 114 BEND OR CAST IRON W COMB.Y&1/8 BEND. WITH CLEANOUTCOMB.Y&118 BEND. O Z (USE REDUCING TYPE FLOOR (USE REDUCING TYPE FOR SIZE CHANGES) FOR SIZE CHANGES) DOMESTIC HOT WAT W DOMESTIC RECIRC RETURN�� R COLD WATER S- \ -�- TE: 11/15/2023 ILDING WASTE BUILDING WASTE DIRECTION OF FLOW OR DRAIN OR DRAIN CHECK VALVE EXTERIOR CLEANOUT TO GRADE(COTG) INTERIOR WALL CLEANOUT(WCO) INTERIOR FLOOR CLEANOUT(FCO) SHEET TITLE: (LIGHT TRAFFIC AREA) INSTALLTHERMAL EXPANSION DETAILS TANK(ET-1) FLOOR CLEANOUTS 2 WALL-MOUNTED WATER HEATER SHEET NO. S—E:NONE S—E NONE P6. 1 /.*I COMBITHERM. Item no. ALT&SHAAM, CTE'rp~ems CTX4 - 10EVH smart® • EcoSmart design uses less electricity than competitive models. The reduced energy setting further minimizes electricity use. • Cooks with variable steam, convection heat, or a combination of both to roast, steam, bake, or oven-fry. Cooking speeds are increased by as much as 70% compared to conventional cooking methods. ® • Cook with the optional product temperature probe or by time. • Boiler-free, flash-steam generation increases reliability by eliminating boiler maintenance and boiler heating element burnout. The steam levels are maintained without a water reservoir. • Two-speed reversing fan design provides excellent baking results and prevents excessive water and power consumption. • Exclusive Gold-n-BrownTM feature on the ExpressTouch Control gives the operator the ability to achieve the ideal cooking environment for the ideal finish. ` • Hand-held sprayer can be used to stop the cooking process in steaming vegetables, add water to your dishes, or rinse the inside oven cavity. • Self-contained, oven venting system features a high-power fan that draws steam and fumes into the hood intake and out the top surface exhaust vent, trapping grease as the air moves through the filter system. Model CTX4-IOEVH • Optional broiler element revolutionizes the utilization of a multi-functional Combi to Capacity: five(5)2-1/2"full-size or 65mm GN 1/1 pans, accommodate new recipe applications and entree finishing [Patent Pending]. ten(10)1-1/4"full-size 20mm GN 1/1 pans, or ten(10)half-size sheet pans • CombiClean®tablet-based cleaning system with a choice of four(4)different levels of cleaning. SHORT FORM SPEC Alto-Shaam Combitherm°countertop Model CTX4-10EVH with stainless steel exteriors and stainless steel interior flash-steam electric CombiOven designed with EcoSmart° cavities. CombiOven includes cool-down function, and four technology for reduced energy usage. The oven includes (4) adjustable bullet legs. Each oven accommodates up to operational modes for steam, convection, and a combination ten (10) half-size sheet pans or five (5) full-size hotel pans, of steam and convection heat. Standard features include: and includes a standard right hinged door,ten (10) non-tilt CombiClean°tablet-based cleaning system with a choice of four support rails with 1-1/2" (38mm) vertical spacing between (4)different levels of cleaning,hand-held sprayer,an integrated rails, and two (2) stainless steel shelves. Oven venting system oven venting system, positive action casual catch door includes one (1) grease and one (1) charcoal filter,with access handle, built-in drip tray,two-speed reversing fan, and from the left side of the oven for easy replacement. Hood removable door gasket. Oven and hood are constructed control includes an ON/OFF switch and indicator light. ❑ ExpressTouch Control: Includes two-speed reversing fan control,retherm mode,moisture injection,six(6)browning levels,reduced energy levels,steam venting,delayed start time,shelf timer,USB port,and software operation in English,French, German,Korean,Mandarin,Russian,and Spanish ❑Single-point product temperature probe,Delta-T and cook&hold functionality(additional option) ❑ Single-point product temperature probe,Delta-T and cook&hold functionality with HACCP data access(additional option) ❑ Broiler element—not available on 1ph units[Patent Pending](reduces pan capacity by one(1))(additional option) • Electrical Choices: • Leg Choices: • Panel Color Choices: ❑208V, 1ph ❑4" (102mm) bullet legs, 5014178, ❑ Stainless Steel, standard c ❑240V, 1ph for countertop applications ❑ Black, optional UJ ❑208 240V, 3ph ❑ 6" (152mm) bullet legs, 5014179, for [I Burgundy, optional Ja ❑208-240V, 1ph floor standing applications, optional ❑ Brown, optional H ❑220-240V, 1ph ❑ Red, optional Z ❑380-415V 3 h ❑ 6" r stand) seismic legs, s, optional for ❑White, optional > p floor standing applications, optional [additional charge applies] ❑ Custom Color, optional o • Door Swing Choices: [longer lead time applies] El Right hinged, standard LL ❑ Left hinged, optional ALTO .SHAAM. W164 N9221 Water Street • P.O.Box 450 • Menomonee Falls,Wisconsin 53052-0450 • U.S.A. V Phone: 262.251.3800 800.558.8744 U.S.A./cANADA Fax: 262.251.7067 800.329.8744 U.S.A.only www.alto-shaam.com #423a-07/18 Printed in the U.S.A. Tiul Due to ongoing product improvement,specifications are subject to change without notice. A LTQ S H AA M COMBITHERM. C T X 4- 10 E V H lj crE_ss,M Bottom az-1/z" (1078mm) Front Back ' 24-1/8"(612mm) \ 20-3/4"(526mm) A=Treated water inlet \ D: " B=Untreated water inlet / (a28mm8mm) C=Water drain c: D=Electrical connection \ 10-7/8" / (276m m) A,B. A:11-1/2" 1 7-1/8 (292mm) I c O (181mm) (211mm) cA 45-1/2" (1153mm) B D C 39-3/8" 20-3/4" (999mm) (527mm) ------------------------------ D:6" (152mm) 17-3/8" (C:5-3/4" 442mm) (145mm) 4"(102mm) 4" 6"(152mm) (102mm) Floor standing units require o 6"leg. Exterior Dimensions(H x W x D) 45-1/2"x 24-1/8"x 39-3/8"(1153mm x 612mm x 999mm) Net Weight 260 lb(118 kg) Ship Dimensions(L x W x H) 43"x 42"x 58"(1092mm x 1067mm x 1473mm)* Ship Weight 415 lb(188 kg)* 'Domestic ground shipping information.Contact factory for export weight and dimensions. WATER REQUIREMENTS WATER QUALITY STANDARDS TWO(2)COLD WATER INLETS-DRINKING QUALITY* It is the sole responsibility of the owner/operator/purchaser of this equipment ONE(1)TREATED WATER INLET: 3/4"NPT connection.Line pressure 30 psi minimum dynamic and to verify that the incoming water supply is comprehensively tested and 90 psi maximum static(200 to 600 kPa)at a minimum flow rate of 0.13 gpm(0.5 L/min). if required,a means of"water treatment"provided that would meet ONE(1)UNTREATED WATER INLET: 3/4"NPT connection.Line pressure 30 psi minimum dynamic and compliance requirements with the published water quality standards shown 90 psi maximum static(200 to 600 kPa)at a minimum flow rate of 2.64 gpm(10 L/min). below.Non-compliance with these minimum standards will potentially Both inlets can be from same source.Divide using a manifold.Run one side through treatmentdevice before runningto oven. damage this equipment and/or components and void the original equipment Must meet line pressure and flow rate specifications for both inlets. WATER DRAIN:1-1/2"NPT(50mm)connection with a vertical vent to extend above the exhaust vent. manufacturer's warranty.Alto-Shaam recommends using OptiPure°[www. Materials must withstand temperatures up to 2007(93°C). optipurewater.com]products to properly treat your water. CLEARANCE REQUIREMENTS Contaminant Inlet Water Requirements LEFT: a"(102mm) 18"(457mm)recommended service access Free Chlorine Less than 0.1 ppm(mg/L) RIGHT: 4"(102mm)Non-combustible surfaces 2"(51mm)door swing or combustible surfaces Hardness 30-70 ppm TOP: 20"(508mm)forair movement Chloride Less than 30 ppm(mg/L) BOTTOM: 4"(102mm)for air movement pH 7.0 to 8.5 BACK: 4"(102mm) Silica Less than 12 ppm(mg/L) INSTALLATION REQUIREMENTS Total Dissolved Solids(tds) Treated line:50-125 ppm •Oven must be installed level. Untreated line:50-360 ppm •Water supply shut-off valve and back-flow preventer when required by local code. ELECTRICAL(DEDICATED CIRCUIT REQUIRED) Certification VOLTAGE PH HZ AMPS kW AWG CORD&PLUG ® 208 1 60 23.4 4.87 — 7 NEMA L6-30P-US only 240 1 60 26.3 6.31 8 no cord or plug 208—240 3 60 15.9—18.8 5.59—7.67 10 no cord or plug IP X4 208—240 1 50 23.4—26.3 4.87—6.31 — 8/3 cord,no plug IP X4 220—240 1 50/60 24.9—26.3 5.47—6.60 no cord or plug IP X4 380-415 3 50/60 9.8-10.8 6.49-7.67 10 no cord or plug ER G CE CAPACITY Product Maximum 48lb(22 kg) Volume Maximum 30 qt(38 Q Pan Capacity=10* Pan Capacity=5* Pan Capacity=3* Half-Size Sheet:1" Full-Size Hotel: 1-1/4" Full-Size Hotel:2-1/2" Full-Size Hotel:4" GN 1/1: 20mm GN 1/1: 65mm GN 1/1: 100mm Half-Size Hotel" 10-3/8 x 12-3/4" Half-Size Sheet: GN 1/2: 265mm x 325mm 18"x 13" (35mm) 22-5/8" 20-7/8" Full-Size Hotel" ;574mm) iir(529rnrn) 20-7/8x 12-3/4" GN 1/1: 530mm x 325mm 12-3/8"(313mm Rack Depth Distance between ledges Cavity Depth 13"(335mm) "Broiler option(gray area)reduces pan capacity by one pan. Rack width "'Hotel pan width varies by brand.Pans with a width less than 12-112"require wire shelves and may require purchase of additional shelves(standard=2)for maximum capacity. #423a-07/18 DUE TO ONGOING PRODUCT IMPROVEMENT,SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. WWW.ALTO-SHAAM.COM CTX4 - 10EVH COMBITHERMa: 345O F CTEx�re o: 1 :43 45 ExpressTouch with programmable control Steam Mode •Automatic steaming at 212°F(100°C). •Quick steaming at 213°F to 250oF(101°C to 121°C). •Low temperature steaming for poaching or proofing. 85°F and 211°F(29°C and 99°C). Combination Mode •Combines steam and convection modes for faster production and better moisture retention. •Improves yield,quality and shelf life. •Automatic humidity control—212°F to 485°F(100°C to 252°C). ® Convection Mode 0 •Cooking,roasting,baking and finishing applications. —85 F to 485 F(290 C to 252 C). Retherm Mode(ExpressTouch only) •Bulk food or plated meal reheating with automatic steam injection. —245°F to 320oF(118°C to 160°C). •Automatic humidity control. ® Broiler Element(Optional on ExpressTouch only) [Patent Pending] •Top heat element accommodates new recipe applications and entree finishing. Gold-n-Brown—(ExpressTouch only) •Gold-n-Brown vents just the right amount of humidity in the oven cavity for perfect browning. Six levels of Gold-n-Brown are featured. © Moisture Injection(ExpressTouch only) •��'+ •A quick burst of moisture can be added with a touch of a button at any time when cooking in the convection mode. Automatic Time Delay(ExpressTouch only) ■ •Quick and simple method to begin preheating your oven while you're away,and ready to go when you are. HACCP Data Access(Optional on ExpressTouch only) •Records cooking mode,time and temperature completed within a two week time period.The information is captured in a text format and can be downloaded to a USB device. www.alto-shaam.com DUE TO ONGOING PRODUCT IMPROVEMENT,SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. #423a-07/18 /1001 CTX4 - 10EVH A LT -S H AA M COMBITHERM. CT Express M OPTIONS&ACCESSORIES ❑ COMBITHERM CLEANING LIQUID—SPECIALLY FORMULATED FOR COMBITHERM OVENS r► TWELVE(12)CONTAINERS/CASE,1 QUART(C.1 LITER) EACH [SPECIAL HANDLING REQUIRED] CE-24750 ❑ COMBICLEAN®COMBITABSTM—SPECIALLY FORMULATED FOR COMBITHERM OVENS r► 90 (0.5 OUNCES) PACKETS EACH CONTAINER CE-28892 COMBIHOODO FILTERS ❑ CHARCOAL FI-24114 ❑ GREASE FI-24113 ❑ EXTENDED ONE-YEAR WARRANTY CONTACT FACTORY ❑ FRY BASKET,12-3/4"x 20-7/8" (325mm x 530mm) BS-26730 ❑ GRILLING GRATE,12-3/4"x 20-7/8" (325mm x 530mm) SH-26731 ❑ POULTRY ROASTING RACK 6 CHICKEN CAPACITY—FITS INSIDE FULL-SIZE PAN:1 RACK PER OVEN SH-23000 ❑ SCALE FREETM(CITRUS BASED, NON-CORROSIVE DELIMING PRODUCT) CE-27889 INSTALLATION OPTIONS ❑ Alto-Shaam Combitherm Factory Authorized Installation Program-AVAILABLE IN THE U.S.AND CANADA ONLY ❑ Installation Start-Up Check-AVAILABLE THROUGH AN ALTO-SHAAM AUTHORIZED SERVICE AGENCY ❑ SHELF,STAINLESS STEEL WIRE,12-3/4"x 20-7/8" (325mm x 530mm) SH-2903 ❑ STACKING KIT,MOUNTING ON TOP OF A 750-S,750-TH-11,750-TH/111,1000-S,1000-TH-11,OR 1000-TH/III 5019679 ❑ STACKING KIT,MOUNTING ON TOP OF QUICKCHILLERTM QC3-3 OR QC3-20 WITHOUT BACKSPLASH 5015781 STAND,STAINLESS STEEL(H x W x D) ❑ STATIONARY WITH DOUBLE SHELF,FOR SINGLE UNITS ONLY(HEIGHT WITH OVEN=77-1/4"[1962mm]) 35-13/16"x 22-1/4"x 31-9/16"(910mm x 565mm x 802mm) 5014985 ❑ STATIONARY WITH DOUBLE SHELF;LOWER SHELF TO HOLD 300-TH/III OR 300-S,(HEIGHT WITH OVEN=77-1/4"[1962mm]) 35-13/16"x 23-3/4"x 31-9/16"(910mm x 603mm x 802mm) 5014986 . 7!11L. 1 Fry Basket BS-26730J_�J�� Grilling Grate SH-26731 Stacking Kit, QC3-3 5015781 Stacking Kit, QC3-20 without backsplash 5015781 #423a-07/18 DUE TO ONGOING PRODUCT IMPROVEMENT,SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. www.alto-shaam.com Vector° H Series Multi-Cook Oven ALT SHAAM U L-Listed Providing an unmatched volume and variety of food,Vector H Series t countertop models are specifically designed for foodservice operations where space is at a premium but food demand is high. Featuring up to four independent oven chambers,operators can control the temperature,fan speed and cook time in each individual chamber for maximum flexibility-simultaneously cooking a variety of menu items with no _ flavor transfer. Exclusive Structured Air Technology®delivers focused heat for faster,more `- au even cooking and consistent,high-quality results. I au Reduce labor by eliminating extra steps in food production and the need to watch and rotate pans. VMC-H4 VMC-H3 VMC-H2 Place anywhere with a small,21"(533mm)footprint and ventless,waterless operation. Configurations(select one) Custom colors available for enhanced branding and a front-of-house Models experience for customers. An advanced control-designed intentionally simple-features an intuitive, These models accommodate a half-size sheet pan ❑ VMC-H2 ❑ VMC-H3 user-friendly interface and programmable recipes to ensure consistency with ❑ VMC-H4 each cook. These models accommodate a full-size hotel pan ChefLincTM,cloud-based remote oven management software,streamlines ❑ VMC-H2H ❑ VMC-H3H processes and maximizes profits with data-driven insights[deluxe control only]. ❑ VMC-H4H ISO 9001:2015-certified Control ❑ Deluxe ❑ Simple Standard Features Kit ❑ Ethernet Cable[5030518] for Deluxe only *Programmable,touchscreen control Door swing •Easy recipe upload/download via USB port ❑ Right hinged ❑ Left hinged •UL-listed ventless catalytic converter •Double-pane glass door Electrical •One[1)wire stainless steel rack and two(2]jet plates per VMC-H2/H2H cooking chamber ❑ 208-240V,1PH,with cord and plug •4"(102mmJ adjustable legs El208-240V,1PH,no cord,no plug(Canada) ❑ 220-240V,1PH,no cord,no plug •Cord and plug on 208-240V models(except Canada) ❑ 380-415V,3PH,no cord,no plug VMC-H3/H3H — El208-240V,1PH,with cord and plug Li208-240V,1PH,no cord,no plug[Canada) 2 VMC-H2:2 shelf,2 half-size sheet pans-18"x 13"x 1" (2 GN 2/3 El208-240V,3PH,with cord and plug / \ pans 354mm x 325mm x 25mm] ❑ 208-240V,3PH,no cord,no plug(Canada) ❑ 220-240V,1PH,no cord,no plug i VMC-H3:3 shelf,3 half-size sheet pans-18"x 13"x 1" [3 GN 2/3 ❑ 380-415V,3PH,no cord,no plug CAPACITY pans-354mm x 325mm x 25mm] VMC-H4/H4H 4 VMC-H4:4 shelf,4 half-size sheet pans-18"x 13"x 1" [4 GN 2/3 ❑ 208-240V,3PH,with cord and plug pans-354mm x 325mm x 25mm] ❑ 208-240V,3PH,no cord,no plug(Canada] ❑ 380-415V,3PH,no cord,no plug 2 VMC-H2H:2 shelf,2 full-size hotel pans-20-3/4"x 12-3/4"x 4" (2 GN 1/1 pans-530mm x 325mm x 65mm)or 2 half-size sheet Accessories pans-18"x 13"x 1"(2 GN 2/3 pans-354mm x 325mm x 25mm) ❑ See accessories brochure for all available accessories 3 VMC-H3H:3 shelf,3 full-size hotel pans-20-3/4"x 12-3/4"x 4" Casters and legs (3 GN 1/1 pans-530mm x 325mm x 65mm)or 3 half-size sheet ❑ 3"[76mm]casters,set of four(4)(5027946) pans-18"x 13"x 1"(3 GN 2/3 pans-354mm x 325mm x 25mm) Cookware 4 VMC-H4H:4 shelf,4 full-size hotel pans-20-3/4"x 12-3/4"x 4" ❑ Jet plate assembly,half-size sheet pan(50252351 ❑ Jet plate assembly,hotel pan(5025236) (4 GN 1/1 pans-530mm x 325mm x 65mm)or 4 half-size sheet ❑ Wire shelf,half-size sheet pan(SH-37662] pans-18"x 13"x 1"(4 GN 2/3 pans-354mm x 325mm x 25mm) ❑ Wire shelf,hotel pan[SH-39077] Cleaning T ElAlto-Shaam®non-caustic cleaner,one(1)bottle(CE-46828) c L: us � LiAlto-Shaam®non-caustic cleaner,case of six[6]bottles[CE- USTEo Q 46829) .1..,.0 "'" ANSI/NSF 4 G I P X4 Grease filters COA#5879 ❑ Internal chamber filters—order one[1]kit per chamber[5027119) Vector° H Series Multi-Cook Oven ALT SHAAM Specification H2,H3,H4:54-3/8"(1382mm) VMC-H2:37-1/2"(953mm) H2H,H3H,H4H:56-3/8"(1432mm) VMC-H2H:39-1/2"(1003mm) 19-9/16" VMC-H2:34-11/16"(882mm) I -- --.1 (546mm) _-- (498mm)� VMC-H2H:36-11/16"(932mm) Ee e e e e e E g eeeeee I ��14-3/6- l---H:19•�453 mmli^ m= r HN 21 l electrical connection Co E oelectrical connection a o o N ro 4-5/16" wmmi 0 Li N o000000® N I � .. I I ` \� 0 16-3/8"(416mm) E �2321/116"(593mm)(688mm) I 21 I 1 Chamber width VMC-H4:37-1/2"(953mm) (535mm) " 0 VMC-H4H:39-1/2"(1003mm) v VMC-H3:37-1/2"(953mm) (2 Chamber depth 21-1/2" r VMC-H4:34-11/16"(882mm) VMC-H3H:39-1/2"(1003mm) (546mm) VMC-H4H:36-11/16"(932mm) I Q3 Chamber height 21-1/2"(546mm) h� VMC-H3:34-11/16"(882mm) VMC-H3H:36-11/16"(932mm) i ®Chamber height with wire shelf ®®o e b electrical connection ®®o 0 o e ` J E E electrical connection E E E r E E E E I zw E m n � io C aM 6"(152mm) I e I I I 16-3/8" mm) 16-3/8" 4-1/4 (108mm E 46mm1 �23-5/16" (46 E �23-5/16"(593mm) ( ) ) 4.15/16"(125mm)J I 21" c 27-1/8"(688mm) 27-1/8(688mm) ————————— 535mm) I (535mm) Model Exterior(H x W x D) Interior(H x W x D) Net Weight VMC-H2 29-5/8"x 21-1/2"x 37-1/2"(752mm x 546mm x 953mm) 14-3/8"x 14-11/16"x 19"(366mm x 373mm x 483mm) 209 lb(95 kg) VMC-H2H 29-5/8"x 21-1/2"x 39-1/2"(752mm x 546mm x 1003mm] 14-3/8"x 14-11/16"x 21-1/2"(366mm x 373mm x 546mm) 213 lb(97 kg) VMC-H3 36-5/8"x 21-1/2"x 37-1/2"[929mm x 546mm x 953mm] 21-3/8"x 14-11/16"x 19"[544mm x 373mm x 483mm] 272 lb[123 kg] VMC-H3H 36-5/8"x 21-1/2"x 39-1/2"(929mm x 546mm x 1003mm) 21-3/8"x 14-11/16"x 21-1/2"[544mm x 373mm x 546mm] 278 lb(126 kg) VMC-H4 43-5/8"x 21-1/2"x 37-1/2"(1108mm x 546mm x 953mm] 28-3/8"x 14-11/16"x 19"[721mm x 373mm x 483mm] 341 lb[155 kg] DIMENSIONS VMC-H4H 43-5/8"x 21-1/2"x 39-1/2"(1108mm x 546mm x 1003mm) 28-3/8"x 14-11/16"x 21-1/2"(721mm x 373mm x 546mm] 348 lb(158 kg) Model Ship Dimensions(L x W x H)* Ship Weight* VMC-H2/H 48"x 29"x 56"[1219mm x 737mm x 1422mm) 291 lb(132 kg] VMC-H3/H 48"x 29"x 56"[1219mm x 737mm x 1422mm) 375 lb(170 kg) VMC-H4/H 48"x 29"x 56"[1219mm x 737mm x 1422mm) 425 lb[193 kg] *Domestic ground shipping information.Contact factory for export weight and dimensions. Vector° H Series Multi-Cook Oven S ALTQiHAAM QNTop: 2"(51mm)* *The oven must be installed level. Left: 2"(51mm) *The oven must not be installed in any area Right: 2"(51mm) where it may be affected by steam,grease, Front: 20"[508mm] dripping water,high temperatures,or any other CLEARANCE Back: 2"(51mm) CHECK FIRST severely adverse conditions. *18"(457mm)recommended for service access *Oven not intended for built-in installation. rA►� Heat of rejection Maximum temperature:525°F(274°C) 1 (((-4 VMC-H Heat Gain Heat Gain \I� qs qs BTU/hr kW HEAT 1898 0.56 TEMPERATURE VMC-H2/VMC-H2H V Ph Hz Awg IEC A Breaker[A) kW Plug Configuration— Certification 208-240V 208 1 1 60 8 25 30* 5.2 NEMA 6-30 �O�$ • 240 1 60 8 — 28 30* 6.7 NEMA 6 30 2WO n MSIMSF4 ELECTRIC 220-240V 220 1 50/60 — 4 25 32* 5.4 No cord,no plug E R[ C E 240 1 50/60 — 4 28 32* 6.4 No cord,no plug 1p X4 380-415V 380 3 50/60 — 1.5 8 16 5.4 No cord,no plug E R[ C E 415 3 50/60 — 1.5 9 16 6.4 No cord,no plug Ip X4 VMC-H3/VMC-H3H 208-240V 208 1 60 6 — 38 50* 7.9 NEMA 6-50 C uL 1 sno 240 1 60 6 — 43 50* 10.3 NEMA 6-50 _ , ANS,MSF4 208-240V 208 3 60 10 — 22 30 7.9 NEMA 15 30P CQ91 LORD 240 3 60 10 — 25 30 10.3 NEMA 15-30P W ° gNSIMSF4 220-240V 220 1 50/60 6 10 37 63 8.1 No cord,no plug E R[ c E 240 1 50/60 6 10 41 63 9.6 No cord,no plug I X4AeX 380-415V 380 3 50/60 — 1.5 13 16 8.1 No cord,no plug E R[ c E 415 3 50/60 — 1.5 14 16 9.6 No cord,no plug I X4 VMC-H4/VMC-H4H 208-240V 208 3 60 6 — 32 40 10.6 NEMA 15-50P y��s 4i• LORD 240 3 60 6 — 36 40 13.9 NEMA 15-50P ANSVNSF4 380-415V 380 3 50/60 — 4 17 32 10.8 No cord,no plug R[ C E 415 3 50/60 — 4 18 32 12.7 No cord,no plug I X4 AVA Electrical connections must meet all applicable federal,state,and local codes. *For use on individual branch circuit only. NEMA 630P NEMA 6-50P NEMA1530P NEMA15-50P **No cord,no plug,in Canada. �n oeo Vector° H Series Multi-Cook Oven S ALTQiHAAM Stacked Configurations and Stands VMC-H on stand 5034115 VMC-H4/H4H 1 VMC-H3/H3H Lbz.. 62-1/8^ VMC-H2/H2H (Sg6mm) (1572mm) 56-1/8•'(1578mm) 5034115 r — — — — — — — — — — � 48-1/8" (1222mm) 2%ImIm) I I I I I 1-1/2"(38mm) 2za r I 2-5/8"(67mm) (572mm) /® L — — — — — — — — — — J 6-11/2^ (165mm) Y - Dimensions shown are with adjustable feet at minimum height. VMC-H on stand 5034118 VMC-H4/H4H VMC-H3/H3H 8mm 1 VMC-H2/H2H (1654 ) 58a/8" 3p, (1476mm) 5034118 s1-1/a•' 1' (1299mm) �-_---------------� 263/4" L (BSAmm) zss 5-1/8"(130mm) LT (654mm) ® i 5-1/4"(133mm) (22 mm) Dimensions shown are with casters at minimum height. VMC-H on stand 5034294 VMC-H4/H4H VMC-H3/H3H 21,1/Z 72" (628mm)1 VMC-H2/H2H ss^ sa'• 5034294 \}\ (1473mm) - 32-3/8" I i 822mm) 1-1/2"(38mm) I 2-5/8"(67mm) I L — — — — — — — — — — J 32-3/8" (822mm) 42) (165mm) Dimensions shown are with adjustable feet at minimum height. k Vector° H Series Multi-Cook Oven S ALTQiHAAM Stacked Configurations and Stands VMC-H on stand 5033311 over VMC-H3 or VMC-H3H with casters VMC-H4/H4H VMC-H3/H3H I I VMC-H2/H2H (2007mm) 114(BhSm - - IN") 2-5/8"(67mm) 72" 33 L — — (1829mm) 5033311 - 65" (1651mm) 37-3/4" arE (959mm) I-T 39-318" (1000mm) 37-3/4" (959mm) 4-1/4" (108mm) Dimensions shown are with adjustable feet at minimum height. Other Bottom Unit Options 300-TH,500-S,500-TH,500-1DN,500-2DN,500-3DN,VMC-H2/H2H VMC-H on stand 5033314 over VMC-H4 or VMC-H4H with casters VMC-H4/H4H VMC-H3/H3H Ji 86" T VMC-H2/H2H 11a — (2184m7 l�5mm jz•(8g8 — —25/8 (67mm)9 mm) L II J (2007mm) 33' - 5033314 72 (1829mm) 44-3/4" • (1137mm) 46-3/8" (1178mm) 44-3/4" (1137mm) 4-1/4" (108mm) 11 1 _,--",--i Dimensions shown are with adjustable feet at minimum height. Other Bottom Unit Options 300-TH;500-S;500-TH;500-1DN;500-2DN;500-3DN;VMC-H2/H2H; VMC-H3/H3H Vector° H Series Multi-Cook Oven ALT SHAAM Alternative Stacked Configurations and Stands VMC-H on stand 5033317 over VMC-H3 or VMC-H31H VMC-H4/H4H 1 VMC-H3/H3H 79" I I (2007mm)� VMC-H2/H2H I I 72° ?-5/8"(67mm) i 1-1/2"(38mm (1829mm) L...... j 65" (1651mm) . 5033317 8 8 8 37-3/4" (959mm) 37-3/4" (959mm) 39-3/8" (1000mm) 4-1/4" (108mm) Dimensions shown are with adjustable feet at minimum height. Other Bottom Unit Options *Smoker models must be under a hood. 300-TH,500-S,500-TH,750-TH,750-S,500-1D,500-2D,500-3D,500-2DI,500- 1DN,500-2DN,500-3DN,VMC-H2/H2H,VMC-H2HW VMC-H on stand 5033384 over VMC-1-112,VMC-H2H,or VMC-H2HW VMC-H4/H4H i VMC-H3/H3H � I � I � I 75-5/8' 7 ,_ � 5-1/8"(130mm) 5-1/4"(M..)I (1921mm) VMC-H2/H2H >��Z- a (1743mm) 61-5/8" (1565mm) 5033383 - r 30-3/4" (781 mm) 8 g g 36" (914mm) 30-3/4" (781mm) 4-1/4" (108mm) T_ Dimensions shown are with casters at minimum height. Other Bottom Unit Options *Smoker models must be under a hood. 300-TH,500-S*,500-TH,750-TH,750-S*,500-1D,500-2D,500-3D,500-2DI,500- 1DN,500-2DN,500-3DN *exluding ovens with 5"[127mm)casters Vector° H Series Multi-Cook Oven ALT SHAAM Alternative Stacked Configurations and Stands VMC-H on stand 5027834 over 500-TH VMC-H4/H4H a VMC-H3/H3H 79" 8 (2007mm) VMC-H2/H2H -- 72" (1829mm) I 1-1/2"(38mm I 65" 2-5/8"(67mm) (1651mm) J 8q 33 5033479 37-3/4" 37-3/4" (959mm) (959mm) 39-3/8" (1000mm) 3-1/2" ■■ ■■ ■■ (88mm) Dimensions shown are with adjustable feet at minimum height. Other Bottom Unit Options 300-TH,500-S,500-TH,500-1DN,500-2DN,500-3DN CTX4-10 on stand 5033312 over VMC-H3 or VMC-H3H 80 5mm) (1851mm) 33" 5033312 - I I I I 2_5/8"(67mm) ----- 8 37 (959mm) 39-3/8" (1000mm) 37-3/4" (959mm) 4-1/4" (lOBmm) Dimensions shown are with adjustable feet at minimum height. Other Bottom Unit Options 300-TH,500-S,500-TH,500-1DN,500-2DN,500-3DN,VMC-H2/H2H W164 N9221 Water Street I Menomonee Falls,Wisconsin 53051 1 U.S.A. Phone:262.251.3800 1 800.558.8744 U.S.A./Canada I Fax:262.251.7067 1 alto-shaam.com VMC-SPC-0005-08/22 Printed in U.S.A. Due to ongoing product improvement,specifications are subject to change without notice. v Chain iod Project p Item No. O O The Dishwashing Machine Specialists Quantity OCC C STANDARD FEATURES DH-6000 = • Factory Authorized Startup with Ventless Heat-Recovery and • Ventless Heat Recovery Condensate Removal M • HMI-Operator Touch Screen Interface • On-Board Service Diagnostics • Field Convertible-three to single phase M • Sleep Programable-All internal heaters shut off after - r1 selected time is reached O • Door Interlock-locks door closed during cycle — T • Auto delime with delime notification Ventless r � • Built-in booster configured to ensure 180' rinse Heat Recovery Champion • Field convertible from straight to corner operation Removal • Dual NSF listed as both a dishwasher and potwasher • Rinse Sentry-ensures 1807 final rinse • Cycle counter • Auto start-starts unit when hood is closed L • Single or dual point electrical connection i • • High efficiency 2 HP pump 11 • Self draining pump • Automatic tank fill • Automatic drain valve-drains wash tank when power is off L�I • PRV(Mounted Pressure Reducing Valve) • 4 selectable cycles Photo is forgeneral visual representation OPTIONS & ACCESSORIES c �� US NSF only.Please refer ductiifi'rmatsforthe O latestdetailedproductinformation. ❑ NEW Built in detergent and rinse aid pumps SPECIFIER STATEMENT ❑ Drain Water Tempering Kit(unmounted) ❑ Racks Specified unit will be Champion model DH-6000 with ❑ Peg Ventless Heat-Recovery and Condensate Removal,high ❑ Flat temperature hood-type dishwashing machine.Features HMI controls,Rinse Sentry,Auto start,up to 40 racks/hour, El Corner operation splash baffle 0.73 US gals/rack[2.76 liters/rack,0.61 imp.gals/rack]. ❑ NEW Champion ION scale prevention system 1 year parts and labor warranty. Champion Industries,Inc. 3765 Champion Blvd.,Winston-Salem,NC 27105 Tel:336/661-1556 Fax:336/661-1979 2674 N.Service Road Jordan Station,Ontario,Canada LOR 1 SO Tel:800/263-5798 Fax:905/562-4618 www.Championindustries.com 7121 Printed in U.S.A. D H-6000 with Ventless Heat-Recovery Champiod and Condensate Removal The Dishwashing Machine Specialists Shipping weight crated:350 lbs. Dimensions shown in inches and[mm] VENTLESSMEAT RECOVERY/CONDENSATE REMOVAL 34" [8631 Rinse Pressure Rinse Aid Gauge Injection O 1/8"NPT 5-3/4' [1451 Min Clearance 17-3/16" [4371 72' [18291 70" Detergent [1778] g7/8aion 3/8" "Dia [1101 50-7/8" Detergent 31-5/8" 0-7/8.[12931 3-9/16" Probe [804] Q2 1911 8-9/16"O 7/8"Dia [2171 11-5/16" $ 6-1M V'r= O[2 881 C [O9] a ® 4-11/16" 11191 Side View Front View [a96] 4-7/16" Side View [1121 10 30" [762] I�/ 5 O 5 18-7/16"[)3 1/2"[32]Roll 7- 4"[184] [1461 146] [4691 6 I to[752nsid] e 6-7/8"O Tank Wall 21-3/8' [1751 [5431 4n3zz�"O Corner Table [291 25-3/8" 6-1/16"O Configuration Typical Table Construction LsF[ Teble [1541 &teRec°71g Plan View Guide UTILITIES [6831 [683] 1 Electrical Machine Connection (See Electrical Box) 2 Cold Water 3/4"NPT Cold Water 50°-75°F Machine&Built-in Booster(Standard) SPECIFICATIONS 45 PSI dynamic min.incoming Max[mum Capacities Rated Min[mum Supply Overcurrent Final rinse 18 PSI Voltage Amps CircuitAmpac Protective Device Racks per hr.(NSF rated) 40 3 Drain 1"NPT Connection 208-240/60/1 77-68 100 100 Wash tank(gal.) 10 Motor horsepower 2 HP Gravity flow,15 GPM max flow 208-240/60/3 46-41 60 60 Water consumption 4 Drain Water Tempering 1/2"Cold water 480/60/3 20 30 30 Gal.per hr. 29 line with customer supplied cut-offvalve Gal.per rack 0.73 (optional) Machine Only Temperature°F (two point electrical connection or no built-in booster) Wash 150 5 Integrated Detergent System Detergent Minimum Maximum Rinse 180 bottle supply connections(optional) Rated SuppplyC[rcu[t Overcurrent Voltage Am Am aci Protective Device Heating Warning:Plumbing,electrical connections should be 208-240/60/1 38-34 50 50 Tank heat,electric 5.2 kW made by qualified personnel who will observe all the 208-240/60/3 25-23 30 30 Electric Booster 7.5 kW applicable plumbing,sanitary and safety codes and the Dish- Pot& National Electrical Code. 480/60/3 11 15 15 washer Pan Note:Optional Drain Tempering:1/2"NPT cold water Mode Mode connection required.1/2"NPT drain connection from back flow BoosterOnl (two point electrical connection) Selectable cycle preventer to house drain.(FIELD INSTALLED and PLUMBED). Minimum Maximum times in minutes 1 2 4 6 Rated Supp[y Circuit Overcurrent Due to an ongoing value analysis program at Volta a Am Ampaci Protective Device Time des in seconds Champion,specifications contained in this catalog 208-240/60/1 39-34 50 50 Wash 36 94 214 334 are subject to change without notice. 208-240/60/3 21-18 25 25 Rinse 8 10270 390 10 10 Champion Industries,Inc., 480/60/3 9 15 15 Sanitary Dwell 16 16 16 16 3765 Champion Blvd.,NC 27105 Vent Fan 3 30 30 30 336/661-1556 • Fax:336/661-1979 Note:Water Hammer Arrestor(meeting ASSE 1010 standard or equivalent) Cham pion Ind ustries.com to besupplied(byothers)incommonwatersupplylineatserviceconnection. Total 90 150 an Ali Group Company AN G R O U P The Spirit of Excellence Project x Item Quantity XASW-03HS—EDDS Date Model Baking speed oven Electric SPEED.ProTm 3 trays 18"x 13"(BAKE) Drop down opening 1 tray 17-23/32"x 13"(SPEED) 6"Touch control panel Description SPEED.Pro-rm is the world's first and only speed baking oven:a convection oven and a speed baking oven in a single piece of equipment.Thanks to the large baking chamber of the SPEED.PrOTM you can use the Bake mode to bake up to 3 460 x 330 trays of bakery or pastry products,even frozen ones,obtaining perfectly I I uniform results.The Speed mode allows you to cook and regenerate food,in single or multiple portions,in record time thanks to the combination of controlled hot air flows,microwave technology and the special Speed.Plate baking tray that transmits heat by contact, perfectly toasting all bread-based products. U_= —�I Standard cooking features Advanced and automatic cooking features Manual cooking Unox Intelligent Performance • Temperature:86°F-500°F • ADAPTIVE.Cooking"':automatically regulates the cooking • Up to 9 cooking steps parameters to ensure repeatable results • 24 quick programs(12 Speed and 12 Bake) • SMART.Preheating:automatically sets the preheating temperature and duration Programs • AUTO.Soft:manages the heat rise to make it more delicate • 384 Bake programs Unox Intensive Cooking • 384 Speed programs • SPEED.PIus:generates microwaves and distributes them • CHEFUNOX:choose something to cook from the library and evenly throughout the baking chamber the oven will automatically set all the parameters(Bake) • DRY.PIus:rapidly extracts humidity from the cooking chamber • SPEEDUNOX:choose something to cook from the library and the oven will automatically set all the parameters(Speed) ' AIR.PIus:multiple fans with reverse gear and 2 speed settings Key features Data Driven Cooking • High-resistance AISI 304 stainless steel cooking chamber • Check and monitor in real-time the operating conditions of your ovens,create and share new recipes.Artificial intelligence • Baking chamber with integrated tray supports transforms consumption data into useful information and • Visual display of the baking status by means of multicoloured allows you to increase daily profits LEDs • Crumb collection system integrated in the filter under the App and web services door Data Driven Cooking app&webapp • Proximity door contact switch • Top Training app • Wi-Fi/USB data:download/upload HACCP data • Combi guru app • Wi-Fi/USB data:download/upload programs C E NSFo c ON . ��� K "This product has been tested in accordance with the procedures and in compliance with the limits prescribed by EPA202.' Unox INC. We deserve the right to make technical improvements 23-3-2022 987 Airlie Parkway-Denver,NC 28037-Tel.1-800-489-UNOX-info.usa@unox.com Pag.1/3 Views x Connection positions Dimensions and weight XASW-03HS-EDDS 796 E31 5/16"1 a 50 C1 15/[6"] 1746 129 3/8"1] 10 38 C1 1/2"] 600 C23 5/8'1 �u m x Q � � H �2 Ln a u CU Q� u - + 6 ID Ln TI 22 C7/8"] 658 125 7/8"1 1102 C43 3/8"1 399 115 11/1 61 1 201 C7 30 11 3/16"1 2 M O 3 2 C, 377 C14 13 16"1 612 124 1/8"] 100 rein C3 15/16"1 100 rein E3 15/16"1 Dimensions and weight Connection positions Width 23-5/8" 600 mm 2 Terminal board power supply 27 Cooling air outlet Depth 31-3/8" 797mm 3 Unipotential terminal Height 21-5/16" 541 mm 6 Technical data plate Net weight 197lbs 89kg 7 Safety thermostat Tray pitch 2-15/16" 75 mm 12 Hot fumes exhaust chimney 13 Accessories connection Unox INC. We deserve the right to make technical improvements 23-3-2022 987 Airlie Parkway-Denver,NC 28037-Tel.1-800-489-UNOX-info.usa@unox.com Pag.2/3 Power supply x Installation requirements Accessories XASW-03HS-EDDS Electrical power supply Acces,nv°-s STANDARD SPRAY&Rinse:Practical spray detergent to manually clean all Voltage 240 V kinds of oven.It degreases and removes all kind of dirt • Baking Essentials:special trays for BAKE mode Phase -3PH+PE • Speed Essentials:special trays and spatulas for SPEED mode Frequency 60 Hz Ethernet:Connection board to keep the oven connected to Total power 5.6-6.5 kW Unox and DDC.App Max Amp draw 17 A Wi-Fi:Connection board to keep the oven connected to Unox Required breaker 30 A cloud,mandatory to extend the warranty size Ventilation Powe cable 4 x AWG 10 Tested by Intertek for ventless operation. requirements* Plug NEMA 15-30P EPA 202 test(8 hr): OPTION A Product Pepperoni Pizzas(150) Voltage 208 V Ventless <5.00 mg/m3 requirement Phase -3PH+PE Result Requirement met Frequency 60 Hz Internal catalytic filtration to limit smoke,grease,and odor Total power 5.6-6.5 kW emissions. Max Amp draw 17.1 A Installation requirements Required breaker 30 A size Installations must comply with all local electrical systems, particularly as for minimum wire gauge required for field Powe cable requirements* 4 x AWG 10 connection,and ventilation supply. Plug NEMA 15-30P *Recommended size-observe local ordinance. Register to DDC Service to access data and product specifications. www.ddc.unox.com Unox INC. We deserve the right to make technical improvements 23-3-2022 987 Airlie Parkway-Denver,NC 28037-Tel.1-800-489-UNOX-info.usa@unox.com Pag.3/3 PLAPL WAINSCOT TYP. PLAM.WAINSCOT TYP. 54'MRL AROUND PERIMETER OF 54"MIL AROUND PERIMETER OF 12' 42•MIN. RESTROOM(ALL WALLS) 42"MR 12" RESTROOM(ALL WALLS) MIN 4'ABOVE FLOOR MIN 4'A50VE FLOOR SOAP DISPENSER SOAP DISPENSER E E Highland Dr 21M 51 HE DEMO EXISTING CLOSET 24536"S.S.MIRROR 24°x3b"SS.MIRROR 39"-41" P.T.DISPENSER 36,MIN. 39'-41' 36°MIN. P.T.DISPENSER1 y P-0. p. IV T-O" a r C l}LEVER HANDLE MIN M MIN FS LFAXEVER HANDLE k cr„L °reeir".N AREA OF WORK C Ip _�mO S mm wwr�v ear 'i TP Y O y 9 O ertvjr e� r° OT0 St NE 24"MM. 24"MIN WRAP PIPEB IN FLOOR 70 SHEET VINYL WRAP PIPES M 42"MAX, RIGID INSUL TO EXTEND UPWARDS Ib"MIN. 41•MAX I6"M.", w/b'COVED BASE RIGID INSUL.70 PREVENT BURNS ON WALL b° IS'MAX is.,MAX PREVENT 51RdS A B A B s o2 RESTROOM ELEVATIONS S RESTROOM ELEVATIONS ?OTst51NE ;, _ �•�� SCALE: 1/4"=1' 0" o SCALE: 1/4"-1'-0" N STSUC71'E A50VE VICINITY MAP --------- SCALE: N.T.S. N KEY PLAN 6"ROCK WOOL CODE INFORMATION SCALE: N.T.S. �),. BRACE•8'-0°OL. t AT DOORS BUILDING AREA: 37,978 S.F. TOTAL BUILDING HEIGHT: 53'-2" CODE: 2018 IBC LEGEND TYPE OF CONSTRUCTION: VA OCCUPANCY: B AL SUER SPRINKLER SYSTEM: YES NFPA 13 EXISTING WALL CEILING' FIRE ALARM: YES 2"GRID T.I. AREA: 2,037 S.F. o NEW WALL ANGLE 2x4 STUDS a Ib"O.C. OCCUPANT LOAD: 39 PERSONS W/R-11 ROCK WOOL 0 CATCH BASIN FILL-IN TO 5/8'CTWB EACH SIDE ALIGN w/WALL MATCH EXISTING 10'-5" II 2x4 P.T.BOTTOM PLATE - IVSECUIRED 70 CONCRETE w/0.145•0IA PINS a 24"O.G. 0 3 e mi a �R DININCs -1 a WIC WIF ROOM 36"MR WIDE 5Y (35)SEATS 36"MAX HIGH DELI INTERIOR WALL MAX°"'" ACCEW15LE COUNTER ,�j o SCALE: 1"=1'-0" F _ ,-T(1 /-TOP TOP F.. �j rIP DJ rrr W ra•D� � _ M - KITCHEN 0 DOOR SCHEDULE Z DOOR DOORS FRAME DOOR KICK 1 PREP/ NOTES N0. WIDTH HEIGHT 1H[q(NESS TYPE MAT FIN MAT FIN HDW TYPE PLATE COOK < 5 ' 1 3'-0" 1 7'-0" 11 3 4" EXISTING DOOR TO REMAIN UNCHANGED 1 � / °!�, � � � � < T 0 2 3'-0" 1 7'-0" 1 1 3 4" A FG P HM P 2 PICK-UP \l� \ J -lOP. 4TQ 4-W drC DI I rQ'D) fv j i maw a- FLOG HARDWARE TYPE or �,- DRAIN bi 1 IEXISTING DOOR HARDWARE TO REMAIN UNCHANGED. ° 2 1 1/2 PAIR BALL-BEARING HINGES, LEVER LATCH SET w PRIVACY LOCK, STOP. 2'- 3'-" NIL ALIGN wl WALL SEATING 5 I SCULLERY Y L_ _J.� eTarArt ;TY OF ARLINGTON � CLOSURE NOTES: T a 1. THE MAXIMUM UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS. `1 1 L- -- �' a A3.0 TY N W ®� BUILDING DEPARTMENT 0 2. ALL CLOSERS TO BE 5 POUNDS MAX. PRESSURE. APPROVED 3. THRESHOLDS TO BE 1/2" BEVELED EDGE MAX, PROVIDE SWEEPS®ALL THRESHOLDS a lcaex `3d r3°•D DATE_4� BY� O 2-TM p UNLESS APPROVED BY THE ZED BUILDING INSPECTOR A A e m ®B .�7TOR46E \ ` L J 0 Received g o oLC2 NOV 3 0 2023 b STLIo DOOR TYPES e'-m"CLR b� '-O" � b'-m"CLR S5 N TOTAL TRAVEL DISTANCE '<100'OK SCALE: 1/4"=l'—O" 0 2 4 8 12 BUILDING 1 FIRST FLOOR PLAN SCALE: 1/4"=1'-0" 1/4"=1'-0 3 ♦♦♦ GLENN 324 WEST BAY DRIVE NW date: 11-15-23 cit issue: 11-16-23 title: sheet no. ♦ ♦ ♦ SUITE 214 3809 RE C;H C WELLS drawn: R.C.T. FIRST FLOOR PLAN ♦##< OLYMPIA, WA 98502 CLENN C.WELLS EDISON CAFE A1.0 ARCHITECT (360) 239-5971 ATE OF WASH[NGTONoo checked: G.C.W. U IC AVE ��Z�i' .." glennwellsarchitect®gmail.com a-,e-z, ARLINGTON,P WASHINGTON E E 4 3 LEGEND 2'X4'LED LIGHT TROFFER Q� TRACK LIGHT FIXTURE O PENDANT LIGHT FIXTURE �Q EXHAUST FAN IEXITI LIGHTED EXIT SIGN/EMERGENCY LIGHT C 0 0 0 0 WALK-IN C LER/FREZER C 0 0 0 OPEN�i0 ABO�J C CC CC 0FQ> aQ> 0 � C C C � a 0 0 �Ol-TR GLL16.CEILING, G1ll.�s;CEILING a u In In n In In 11 01 1 m ______ m 3 a H w x F N v v 11 2 4 8 12 BUILDING 1 FIRST FLOOR REFLECTED CEILING PLAN SCALE: 1/4"-1'-B" 1/4 1'-0", 3 ♦�♦ `cit issue: 11-16-23 title: sheet no. GLENN 324 WEST BAY DRIVE NW date: 11-15-23 ♦ • ♦ SUITE 214 3809 RE'0 FIRST FLOOR REFLECTED CEILING PLAN ' • • . GH EC drawn: R.C.T. ��•��� WELLS OLYMPIA, WA 98502 .;,.,,. GLENN WELLS EDISON CAFE A2.0 (360) 239-5971 ATE OF WASHINGTON checked: G.C.,1. •�= ARCHITECT - DLYMPIC AVE glennwellsarchitect�gmail.com E,,.,e_,e_„ IL ARLINGTON, WASHINGTON sof E u_ 3 LEGEND REQUIREMENTS GENERAL NOTES ABBREVIATIONS 1) ALL DEVICES, WIRING, AND INSTALLATION IS NEW, UNLESS NOTED OTHERWISE. GENERAL A AMPERE GENERAL CONTRACTOR SHALL MAINTAIN POWER, DATA WIRING, AND FUNCTIONALITY OF ALL AC ALTERNATING CURRENT EQUIPMENT AND DEVICES DESIGNATED AS EXISTING TO REMAIN OR RELOCATED EXISTING. 1. PROVIDE ELECTRICAL INSTALLATION IN ACCORDANCE WITH AFF ABOVE FINISHED FLOOR LIGHT LINE INDICATES NON—ELECTRICAL OR BACKGROUND CONTRACTOR SHALL WARRANTEE ALL WORK FOR NO LESS THAN ONE YEAR. NATIONAL ELECTRICAL CODE, LOCAL CODES, AND ORDINANCES. AIC AMPS INTERRUPTING CAPACITY (THIS IS NOT CONTRACTUAL DEFINITION OF WORK) AL ALUMINUMAMP AMPERE z 2) PROVIDE A MINIMUM SIZE OF 3/4" CONDUIT. AWG AMERICAN WIRE GAUGE r Z O HEAVY LINE INDICATES NEW WORK 2. PROVIDE ITEMS NECESSARY TO COMPLETE ELECTRICAL SYSTEMS. w o 5 (THIS IS NOT CONTRACTUAL DEFINITION OF WORK) 3) REFER TO ARCHITECTURAL SET FOR ALL RECEPTACLE MOUNTING HEIGHTS. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND DO NOT BKR BREAKER d NECESSARILY SHOW EVERY CONDUIT, BOX, CONDUCTOR OR DETAIL IDENTIFICATION OTHERWISE, ALL RECEPTACLES MTD 18" A.F.F. SIMILAR ITEMS FOR A COMPLETE INSTALLATION. BLDG BUILDING 4) REFER TO ARCHITECTURAL SET FOR ALL SWITCHES MOUNTING HEIGHTS. C COIL or CONDUIT In SYMBOL NAME 3. WHEREVER THE WORD "PROVIDE" IS USED, IT MEANS, "FURNISH CKT CIRCUIT a OTHERWISE, ALL SWITCHES MTD 48" A.F.F. AND INSTALL COMPLETE AND READY FOR USE." CO CONDUIT/RACEWAY ONLY G5 ALL DEVICES TO MATCH BUILDING STYLES U.N.O. CT CURRENT TRANSFORMER < 4. VERIFY ALL FINAL ROOM NAMES AND NUMBERS WITH OWNER PRIOR a DETAIL, DIAGRAM, OR PARTIAL PLAN Cu COPPER � o TO PREPARING PERMANENT PANEL SCHEDULES. CW COOL WHITE 6) THE CONTRACTOR SHALL REFER TO THE STRUCTURAL, PLUMBING, HVAC, FIRE PROTECTION, AND ARCHITECTURAL DRAWINGS BEFORE INSTALLING ANY ELECTRICAL 5. NOT ALL SYMBOLS AND ABBREVIATIONS ARE USED. D DIMMER EQUIPMENT. TS EXIST DEDICATED SECTION 7) ALL WIRES, TERMINATIONS, & DEVICES SHALL BE RATED 75'C. ALL BRANCH CIRCUIT R I WIRING, AND DISTRIBUTION FEEDERS SHALL BE COPPER WITH THHN/THWN INSULATION EXIST EXISTING 1. BRANCH CIRCUIT CONNECTIONS ARE SHOWN FOR THE SOLE PURPOSE OF EF EXHAUST FAN UNLESS NOTED OTHERWISE. oo❑Opp ALL DETAIL SYMBOLS CONTAIN INDICATING ALL OF THE DEVICES WHICH ARE TO BE CONNECTED TO A ELEC ELECTRICAL OO��STEA�*O THE FOLLOWING INFORMATION: 8) ALL COMPONENTS FURNISHED BY THE CONTRACTOR SHALL BE UL LISTED FOR THEIR PARTICULAR BRANCH CIRCUIT. CONDUCTOR SIZES AND/OR QUANTITIES EMT ELECTRICAL METALLIC TUBING ARE NOT INDICATED FOR 20 AND 15 AMP, BRANCH CIRCUITS. EQUIP EQUIPMENT SEQUENTIAL CHARACTER (BY SHEET) INTENDED USE. CONDUCTOR SIZES AND/OR QUANTITIES ARE ONLY INDICATED WHERE ❑❑ Z`. o ALPHABET= SECTIONS & ELEVATIONS OVERSIZED CONDUCTORS ARE REQUIRED TO MINIMIZE VOLTAGE FACP FIRE ALARM CONTROL PANEL ❑ 9) CONTRACTOR SHALL PROVIDE FULLY RATED ELECTRICAL EQUIPMENT OF THEIR p NUMBER = DETAILS & PARTIAL PLANS DROP OR ON BRANCH CIRCUIT CONNECTIONS WHICH ARE NOT FED FLUOR FLUORESCENT �s I NAMEPLATE VALUES. BY 15 OR 20 AMP CIRCUIT BREAKERS. THE ELECTRICAL CONTRACTOR DRAWING CONTAINING SECTION, ELEVATION, SHALL DETERMINE RACEWAY ROUTING, GROUPING OF BRANCH CIRCUITS GFCI GROUND FAULT CIRCUIT INTERRUPTER O /QWL E-1 E-1 10) THE CONTRACTOR SHALL PROVIDE BOX, CONDUIT AND PULL STRING FOR GNO GROUND `J PARTIAL PLAN, OR DETAIL COMMUNICATION CABLES. COORDINATE WITH SECURITY AND COMM/DATA VENDORS AND FOR HOMERUNS, NUMBERS OF CONDUCTORS REQUIRED AND PLACEMENT GRS GALVANIZED RIGID STEEL ❑❑00 �`'� OF JUNCTION BOXES. SHOW ACTUAL RACEWAY ROUTING AND CIRCUITING DRAWING CONTAINING PLAN AT WHICH SECTION, DETERMINE REQUIREMENTS. ON RECORD DRAWINGS. ELEVATION, PARTIAL PLAN, OR DETAIL APPLIES HID HIGH INTENSITY DISCHARGE (NOT ALWAYS USED) # 11) ALL WIRING SHALL BE ROUTED PERPENDICULAR TO COLUMN LINES. 2. PROVIDE #10 CONDUCTORS IN LIEU 12 IN 20A CIRCUIT HOMERUNS HP HORSEPOWER LONGER THAN 75 FEET. KCMIL THOUSAND CIRCULAR MILLS FLAG NOTE 12) CONTRACTOR SHALL COORDINATE ELECTRICAL SYSTEM SHORT—CIRCUIT WITHSTAND KVA KILOVOLT AMPERES AND INTERRUPT WITH THE SHELL ELECTRICAL SYSTEM AND DESIGN. LIGHTING KW KILOWATT R 0 REVISION NOTE 13) CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION & 1. SUPPORT LIGHT FIXTURES FROM BUILDING STRUCTURE. DO NOT LTG LIGHTING y 'OBISON QUANTITIES OF ALL DEVICES. SUPPORT FIXTURES FROM SUSPENDED CEILING. LV LOW VOLTAGE REVISION DEFINITION, AREA ENCIRCLED 2. PROVIDE LIGHT FIXTURES WITH PROPER FITTING FLANGES, ENGINEERING,INC CONTAINS DRAWING CHANGES MADE 14) CONTRACTOR SHALL MATCH BUILDING STANDARDS FOR ALL ELECTRICAL DEVICES, MOUNTING SUPPORTS, AND ACCESSORY ITEMS, UL LISTED FOR MFR MANUFACTURER mownx�� COVER PLATES, RECEPTACLES AND THE LIKE. TRIMS, FINISHES AND COLORS SHALL BE CONDITIONS OF USE. MIN MINIMUM ms�xia3as,a SUBSEQUENT TO PREVIOUS ISSUE COORDINATED THROUGH THE ARCHITECT. MLO MAIN LUGS ONLY REtvRaEcrrvo_sszozo CQYfA(.T:'Ell FUCKSIFA� 3. THE MAXIMUM LIGHTING POWER THAT MAY BE CONTROLLED FROM N NEUTRAL 15) CONTRACTOR SHALL GUARANTEE ALL WORK PERFORMED AS PART OF THIS A SINGLE SWITCH OR AUTOMATIC CONTROL SHALL NOT EXCEED NEC NATIONAL ELECTRICAL CODE (NFPA-70) LIGHTING CONTRACT IS FREE FROM DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF THAT WHICH IS PROVIDE BY A TWENTY AMPERE CIRCUIT NEMA NATIONAL ELECTRICAL MANUFACTURERS SUBSTANTIAL COMPLETION. EC SHALL REPLACE OR REPAIR ANY DAMAGED OR DEFECTIVE LOADED TO NOT MORE THAN EIGHTY PERCENT. A MASTER ASSOCIATION DEVICES OR WORK FREE OF CHARGE DURING THIS PERIOD. CONTROL MAY BE INSTALLED PROVIDED THE INDIVIDUAL SWITCHES NTS NOT TO SCALE F2 FIXTURE IDENTIFICATION SYMBOL RETAIN THEIR CAPABILITY TO FUNCTION INDEPENDENTLY. PNL PANEL m m = SEE LUMINAIRE SCHEDULE FOR FIXTURE SYMBOLS 16) A MANUFACTURER'S SPEC SHEET(INCLUDING CATALOG NUMBER AND SHOP POC POINT OF CONNECTION g g a DRAWINGS) SHALL BE SUBMITTED FOR APPROVAL ON ALL DISTRIBUTION RACEWAYS AND 4. CIRCUIT BREAKERS MAY NOT BE USED AS THE SOLE MEANS PT POTENTIAL TRANSFORMER WIRING, FIXTURES, DEVICES AND EQUIPMENT PRIOR TO PURCHASING. OF SWITCHING. PVC POLYVINYL CLORIDE PWR POWER z w ' o 17) ALL WIRING SHALL BE IDENTIFIED WITH PANELBOARD AND CIRCUIT NUMBERS IN ALL a JUNCTION BOXES, TROUGHS, POINTS OF TERMINATION, ETC. QTY QUANTITY m w m GROUNDING o o a SWITCHES 18 CONTRACTOR SHALL CLEAN, VACUUM & TIGHTEN ALL CONNECTIONS FOR ALL RECEPT RECEPTACLE ) 1. GROUND ALL ELECTRICAL DEVICES, MOTORS, METALLIC PIPING, RI ROUGH—IN SWITCH, SINGLE POLE; WITH SWITCHING SUBSCRIPT ELECTRICAL DISTRIBUTION EQUIPMENT THAT IS TO BE RE—USED. DUCTWORK, METAL FRAMING, REINFORCING STEEL, ETC., IN RM ROOM 19 ALL KNOCKOUTS IN ALL ENCLOSURES SHALL BE SEALED. ACCORDANCE WITH NEC ARTICLE 250. RO RACEWAY ONLY THERMAL OVERLOAD MOTOR STARTER SWITCH ) UTILIZE THE METALLIC RACEWAY SYSTEMS AS THE �^^ SYSTEM GROUNDING PATH FOR ALL DEVICES UNLESS OTHERWISE SHT SHEET 20) CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN UPDATED TYPED CIRCUIT NOTED. PROVIDE SEPARATE GREEN GROUNDING CONDUCTOR FOR SPEC SPECIFICATIONS $a SWITCH, SINGLE POLE; WITH SWITCHING SUBSCRIPT DIRECTORY FOR ALL PANELBOARDS THAT ARE AFFECTED BY THE CONSTRUCTION. ALL FLEXIBLE EQUIPMENT CONNECTIONS AND ALL EXTERIOR SW SWITCH D "D" INDICATES WALLBOX DIMMER ELECTRICAL DEVICES, SUCH AS POLE MOUNTED LIGHTING, SNBD SWITCHBOARD � 21) CONTRACTOR SHALL PROVIDE ENGRAVED NAMEPLATES FOR ALL PANELBOARDS, RECEPTACLES, BUILDING MOUNTED LIGHTING, ETC. SWGR SWITCHGEAR fl 1\0 SWITCH & CONTROLLED OUTLET OR FIXTURE JUNCTION BOXES, DISCONNECT SWTCHES AND TRANSFORMERS. TYP TYPICAL 22) CONTRACTOR SHALL CROSS REFERENCE AND IDENTIFY ALL EQUIPMENT THAT ® RELAY REQUIRES ELECTRICAL AND FIRE ALARM SERVICE WITH ALL OTHER TRADES. UG UNDERGROUND LIGHTING CONTROL COMMISSIONING UL UNDERWRITERS LABORATORIES $T SWITCH WITH TWIST TIMER 22) CONTRACTOR SHALL REVIEW PROJECT SPECIFICATIONS FOR ALL ELECTRICAL WORK. 1. OCCUPANCY SENSORS, PHOTOCELLS, CONTACTORS AND OTHER LION UNLESS OTHERWISE NOTED N w VACANCY SENSOR WALL SWITCH LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT WI CV $os 23) CONTRACTOR SHALL UTILIZE THE MOST STRINGENT SPECIFICATIONS IN THESE CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS V VOLTS �..L 00 DOCUMENTS. IF THERE ARE ANY CONFLICTS OR CONTRADICTIONS, THE MOST STRINGENT ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE W WATTS O1 SPECIFICATIONS SHALL APPLY. WITH APPROVED PLANS AND SPECIFICATIONS. WW WARM WHITE Q N OS CEILING MOUNTED OCCUPANCY SENSOR WP WEATHERPROOF U o w WTH 2. SUBMIT A REPORT OF TEST PROCEDURES AND RESULTS TO W/0 WITHOUT N m m PS a b PHOTOSENSOR FOR DAYLIGHT ZONE. LETTER THE OWNER. INDICATES LIGHTING ZONE CONTROLLED BY SENSOR WSNREC WASH. STATE NONRESIDENTIAL w ENERGY CODE +— RECEPTACLES XFMR TRANSFORMER CITY OF ARLINGTON (3) ¢3 m J Cm2 p o DUPLEX RECEPTACLE XFR TRANSFER BUILDING DEPARTMENT w _ 00 A�BY Q 3 W $GFCI DUPLEX RECEPTACLE WITH GROUND FAULT CIRCUIT Z IMPEDANCE OR ZONE o z z INTERRUPTER (GFCI). INDICATES MOUNTING HEIGHT SHOWN. DATE BY °' a 10 CLG SHOW WINDOW RECEPTACLE NOO ANGESAVEDBYTH z U ^ UNLESS APPROVED BY THE � CEILING MOUNTED DUPLEX RECEPTACLE BUILDING INSPECTOR Z E Z Z O ® SPECIAL EQUIPMENT O CONTROLLED RECEPTACLE DRAWING INDEX � � m W OTHER O Z ® SPECIAL HARDWIRED ELECTRICAL CONNECTION U FUSED DISCONNECT SWITCH a W J JUNCTION BOX INCLUDED IN SET DATE: 11/15/2023 IOW VOLTAGE EQUIPMENT FOR REFERENCE ONLY. CONFIRM WITH LOW VOLTAGE VENDOR 0 BROADBAND OUTLET SHEET TITLE: TELEPHONE OUTLET Do u-m+oWG DESCRIPTIONµ N Ec LEGEND,GENERAL 00 NOTES,DRAWING ' oc couvuAR-"" INDEX v -unw 1 -R A Received SHEET NO. NOV 302023 EO.00 LUMINAIRE SCHEDULE GENERAL LIGHTING NOTES T LIGHTING CONTROLS SHALL BE INSTALLED WHICH MEET ALL REQUIREMENTS OF LOCAL ENERGY CODES. CALLOUT SYMBOL MOUNTING DESCRIPTION MODEL VOLTAGE TYPE LAMPING WATTAGE NOTES 2. EMERGENCY LIGHT FIXTURES:PROVIDE UNSWITGHED HOT. 3. LOCATIONS OF OCCUPANCY SENSORS,PHOTO SENSORS,DIMMERS,AND SWITCHES ARE DIAGRAMMATIC. Al SURFACE 4" CYLINDER PENDANT DIVE: DC4 C2 S S D 12 FL 0 00 00 40 120 0-10V DIMMING (1) 14W LED 14 90 / 4000K CONTRACTOR TO COORDINATE QUANTITIES AND OPTIMAL LOCATIONS WITH LIGHTING CONTROL [FINISH] 0 OO R DGGX-J MANUFACTURER AND ARCH/OWNER. 4. AUTOMATIC LIGHTING SHUT-OFF CONTROLS SHALL BE PROVIDED BY LOCAL OCCUPANCY SENSORS UNLESS 60 OTHERWISE NOTED.PUBLIC SPACES ARE ACTIVE 24/7 AND THEREFORE EXEMPT FROM AUTOMATIC LIGHTING Z A2 SURFACE DCCxxxx4D-15F-0000-30-Wx T9MF Lighting, 120 0-10V DIMMING (1) 14W LED 18.7 90 / 4000K SHUT-OFF REQUIREMENTS FOR SECURITY(WSEC C405.2) o DCCxxxx4D-15F-0000-30-Wxx-R z GO 5. DAYLIGHT ZONES ARE SHOWN ON PLANS AS DEFINED BY WASHINGTON STATE ENERGY CODE(WSEC) W o j C405.2.4.2.SIDELIGHT DAYLIGHT ZONES ARE REFERRED TO AS'PRIMARY AND'SECONDARY ON PLANS AND o H- W B1 RECESSED GR 2'X4' LED TROFFER w/ F1 COOPER LIGHTING SOLUTIONS - METALUX 120 0-10V DIMMING (1) 56W 3500K 48.7 80 / 3500K DENOTED BY DASHED LINES. CL EC LENS (FORMERLY EATON), CCT, 80 CRI F� 6. FOR CUSTOM FF&E FIXTURES,IT IS THE MANUFACTURER'S RESPONSIBILITY TO FURNISH PRODUCTS WHICH U 24GR-LD5-72-F1-UNV-L835-CD1-U LEDS ARE COMPLIANT WITH ALL REQUIREMENTS OF LOCAL ENERGY CODES,AS WELL AS MATCH THE ELECTRICAL CC 00 SPECIFICATIONS PROVIDED IN THE LUMINAIRE SCHEDULES.PROVIDE SUBMITTAL SHOP DRAWINGS WITHIN 30 Lj d LJ B2 RECESSED 1X4 TROFFER - LAUNDRY / COOPER - METALUX: 14GR LDS 72 F1 120 0-10V DIMMING (1) 56W LED 56 80 / 3500K DAYS OF RECEIVING FIXTURE ORDER,SUBMITTALS SHALL CLEARLY INDICATE LAMPING AND MAXIMUM WATTAGE RATING OF LAMP SOCKETS.NON-COMPLIANT FIXTURES REJECTED BY ELECTRICAL INSPECTOR FOOD PREP /HOUSEKEEPING UNV L835 CD1 U SHALL BE RETURNED TO THE MANUFACTURER FOR REWORKING AND/OR RE-LABELING. ]. ALL FIXTURES SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. \ ¢ BATTERY BACKUP - HATCH X1 ® SURFACE EXIT SIGN EMERGENCY LSI: EMS WE SERIES (OR EQUAL) MULTIPLE EM (1) SW EM 5 EM / EM 8. CONTRACTOR SHALL BE RESPONSIBLE TO ORDER ALL NECESSARY HARDWARE,ELECTRICAL CABLE,TIMERS,INDICATES LIT FACE TRANSFORMERS,ETC.,AS REQUIRED FOR COMPLETION OF INSTALLATION OF A FULLY FUNCTIONING SYSTEM. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR EQUIPPING ALL FIXTURES WITH THE EXACT LAMPS SPECIFIED IN THE FIXTURE SCHEDULE. � Z 10.WHERE FIXTURES REQUIRE REMOTE TRANSFORMERS OR BALLASTS,THE CONTRACTOR SHALL DETERMINE LOCATIONS AS REQUIRED FOR EVEN LOAD DISTRIBUTION,SERVICE ACCESS,AND VENTILATION. 11,THE CONTRACTOR SHALL COORDINATE WITH THE ELECTRICAL ENGINEER FOR EXACT LOCATIONS OF TIMERS 130 AND/OR PHOTO CELLS,IF ANY. 12.WHERE APPLICABLE,THE CONTRACTOR SHALL AIM AND ADJUST LIGHTING FIXTURES AS DIRECTED BY THE ............ y LIGHTING DESIGNER UPON COMPLETION OF THE INSTALLATION. SPECIAL NOTE TO THE CONTRACTOR m (� pAo 13 O 1. FIXTURE SUBMITTALS THAT DO NOT INCLUDE LAMP SPECIFICATIONS WILL BE CONSIDERED INCOMPLETE AND O WILL NOT BE RENEWED. 155 �p O LIGHTING CONTROL SYSTEM REQUIREMENTS Do �A\ 23 1. CONTRACTOR TO PROVIDE A FULLY OPERATIONAL LIGHTING CONTROL SYSTEM. 1/ 2. CONTRACTOR SHALL VERIFY THE COMPATIBILITY OF DIMMING AND CONTROL MODULES WITH FIXTURE TYPES PRIOR TO INSTALLATION. 3. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH A LIGHTING CONTROLS VENDOR TO OBTAIN LIGHTING rn CONTROL SYSTEM PACKAGE COMPLETE WI1H DEVICES,WIRING DIAGRAMS,ANNOTATED PLANS INDICATING " ~ WHICH DEVICE TO BE USED IN EACH LOCATION,CONNECTEN REQUIREMENTS,SET UP INSTRUCTIONS, COMMISSIONING AND CHECK-OUT FOLLOWING COMPLETION.PROVIDE ALL LOW VOLTAGE WIRING AS REQUIRED FOR CONTROL DEVICE INTERCONNECTIONS. 4. INSTALLER QUALIFICATIONS:TECHNICIAN INSTAWNG AND WIRING THE LIGHTING CONTROL SYSTEM SHALL o B i s o ry HAVE INSTALLED THIS SAME SYSTEM AT LEAST ONCE PREMOUSLV,TECHNICIAN SHALL HA RECEIVED R TRAINI VE NO BY FACTORY REPRESENTATIVE ON THE SYSTEM BEING INSTALLED. 5. PROVIDE LIGHTING CONTROL SYSTEM TO PERFORM THE FUNCTIONS DESCRIBED BELOW: ENGINEERING,INC 40TH AVE W.,SUITE3c2 5.1. PROVIDE MULTI-SCENE DIMMING SCHEDULING AND CONTROL.INSTALLER TO COORDINATE SCENE Y NNWOOD,WA-6 CON FIGURATIONS WITH BRAND AND PROPERTY MANAGER. 20636b3343m 5.1.1. PROVIDE KEYPAD CONTROLS STATIONS FOR SELECTING LIGHTING SCENES AND FOR MANUAL ON/OFF REIPROJECTNO.:96— AND MULTI-LEVEL LIGHTNG CONTROL.REFER TO PLANS FOR KEYPAD LOCATIONS. CONTACT PETERROCKsTEND 5.2. LIGHTING CONTROL SCHEDULE:PROVIDE SEPARATE SWITCHING AND DIMMING CONTROL FOR LIGHTING ZONES AS INDICATED. 5.3. AUTOMATIC LIGHTING CONTROLS: 5.3.1. UNLESS OTHERWISE NOTED ON PLANS,OCCUPANCY SENSORS SHALL AUTOMATICALLY TURN OFF ALL CONNECTED LIGHTING WITHIN 30 MINUTES OF SPACE BEING UNOCCUPIED.OCCUPANCY SENSORS SHALL EITHER BE MANUAL ON OR SHALL BE CONTROLLED TO AUTOMATICALLY TURN THE LIGHTING m m LO ON TO NOT MORE THAN 50 PERCENT POWER EXCEPT WHERE MANUAL ON WOULD ENDANGER THE W EL = Of SAFETY OR SECURITY OF THE ROOM OR BUILDING OCCUPANTS.(C405.2.1.1) LL 53.2. MULT-ZONE PHOTO-SENSORS SHALL PROVIDE SEPARATE CONTROL FOR LUMINAIRES IN EACH TYPE OF DAYIJGHT ZONE.(C4O5.2.4A) 5.3.3. EXTERIOR LIGHTING CONTROLS SHALL AUTOMATICALLY TURN OFF LIGHTING AS A FUNCTION OF o W AVAILABLE DAYLIGHT.BUILDING FACADE AND LANDSCAPE LIGHTING SHALL HAVE CONTROLS THAT Z Z LO oAUTOMATICALLY SHUT OFF THE LIGHTING AS A FUNCTION OF UAWN/DUSK AND A SET OPENING 3 o U EC TIME AND CLOSING TIME.OTHER LIGHTING SHALL HAVE CONTROLS CONFIGURED TO AUTOMATICALLY ¢ N W W REDUCE THE CONNECTED LIGHTING POWER BY AT LEAST 30 PERCENT FROM NO LATER TITAN 12 O_ W = LL MIDNIGHT TO 6 AM OR FROM ON HOUR AFTER BUSINESS CLOSING TO ONE HOUR BEFORE BUSINESS O p U ¢ OPENING OR DURING ANY PERIOD WHEN NO ACTIVITY HAS BEEN DETECTED FOR A TIME OF NO LONGER THAN 15 MINUTES.(C405.2.7) 6. DURING EMERGENCY CONDITIONS EMERGENCY LIGHTING CIRCUITS SHALL BYPASS ALL LIGHTING CONTROLS IN ORDER TO ENERGIZE ALL CONNECTED LUMINAIRES AT FULL CAPACITY.PROVIDE UL924 RELAYS AS REQUIRED TO BYPASS AREA CONTROLS. 6.1. EMERGENCY PATHWAY EGRESS LIGHTING:ILLUMINATION PROVIDED ALONG THE EGRESS PATH AT FLOOR LEVEL SHALL AVERAGE AT LEAST 1 FOOT CANDLE.(SBC 1008.3.5) 6.2. EMERGENCY LIGHTING SHALL BE SUPPLIED BY:TBD EXIT SIGN NOTES DURING CONSTRUCTION UPON COMPLETION OF A TYPICAL FLOOR FRAMING AND BEFORE WALL COVER, ELECTRICAL CONTRACTOR SHALL WALK THE EGRESS PATHS WITH THE LOCAL INSPECTOR(AHJ)TO CONFIRM THAT ALL THE EXIT SIGNS ARE LOCATED PER THE AHJ'S SATISFACTION AND IDENTIFY ANY ADDITONAL EXIT C'7 SIGNS THAT THE AHJ WISHES TO BE INSTALLED(IBC 1013.1).CONTRACTOR SHALL PROVIDE UP TO 10% ADDITIONAL EXIT SIGNS AT NO ADDITIONAL COST. w N U— co 01 LIGHTING CONTROLS LEGEND Q < N �A TOGGLE SWITCH FOR MANUAL ON/OFF LIGHTING CONTROL SUBSCRIPT INDICATES WHICH UW �D FIXTURES ARE TO BE CONTROLLED BY WHICH SWITCH.(WSEC C405.2.3) GO cp N o CO 06 O 3DOM a DIMMER SVATCH FOR MANUAL MULTI-LEVEL LIGHTING CONTROL.SWITCH SHALL ALSO HAVE DUUO ¢ IWII MANUAL ON/OFF FUNCTIONALITY.SUBSCRIPT INDICATES WHICH FIXTURES ARE TO BE ¢GO m CONTROLLED BY WHICH DIMMER.(C405.2.3) J H cl 0 uj Q ,3 N IaI SWITCHES LABELED'OS'SHALL TURN OFF ALL CONNECTED LUMINAIRES WITHIN 30 MINUTES OF Q p 2 0 SPACE BEING VACANT.(C405.2.1.1) z a TIP WALLBO%DIMMER OR SWITCH FOR MANUAL LOCAL LIGHTING CONTROL.WALLBOXES SHALL ALSO U A HAVE MANUAL ON/OFF FUNCTIONALITY OF ALL CONNECTED LUMINAIRES.SUBSCRIPT INDICATES Z ®® WHICH FIXTURES ARE TO BE CONTROLLED BY ZONE ACCORDING TO LIGHTING CONTROL Z Q SCHEDULE(130.1(b)).SUBSCRIPT'TR'INDICATES TAMPER RESISTANT CONTROLS TO BE O C ACCESSED BY AUTHORIZED PERSONNEL ONLY. C O w ® MINUTESCY OF SPACERBENGL VACANT.ATICALLY(C404.2.1NRN OFF ALL CONNECTED LUMINAIRES WITHIN 30 //1 O U) vZ Ln 0 CD ® MUTLIZONE PHOTOSENSOR FOR DAYLIGHT ZONE CONTROL SHALL AUTOMATICALLY ADJUST THE N W LIGHT OUTPUT OF ALL CONNECTED LUMINAIRES BASED ON THE DAYLIGHT LEVEL IN THE LIJ PRIMARY AND SECONDARY ZONES.(C405.2.4) O LO U a W DATE: 11/15/2023 SHEET TITLE: LUMINAIRE GENERAL NOTES, SCHEDULES SHEET NO. E 1 .00 COPYRIGHT 2023.ROBISON ENGINEERING,INC MBENZAR E\1131-003 JUST POKE IN SNON ISH,WA\DWG\E3.W POINER.M 04-28 2023 12:24 GENERAL NOTES 1. EMERGENCY EGRESS LIGHTING: TDD. 2. REFER TO SERIES E3.00 DRAWINGS FOR ELECTRICAL AND PANEL LAYOUT. 3. SEE SHEET E1.00 FOR LUMINAIRE SCHEDULE AND LIGHTING NOTES. � FLAG NOTES o N O 1. EXIT SIGNS: PROVIDE UNSWITCHED HOT. IN ADDITION TO N w STANDARD HIGH LEVEL EXIT SIGNS, PROVIDE LOW LEVEL EXIT a SIGNS IN ALL INTERIOR CORRIDORS OF GROUP R, DIVISION I 5 (6.7 7 (7.5 8 OCCUPANCIES AS INDICATED ON PLAN. (TYP) (IBC 1013.2) w w a o 2. PROVIDE TAMPER RESISTANT LIGHTING CONTROLS. (TYP) a . . . . . . . . > o 0 z P..S... O ._X A O ° g` o T ° � g `a�/CNAL '\p0� 38 38 38 f3 (40 �O°°°°1 5�23 T T T T Al Al Al 38 T 38 T 38 RoBisory ENGINEERING,INC amN.—s11-02 O TB1 NNJl000,WA9B036 A2 40 LY 20636b33E3m REIPROJECTN0.:9fi2020 38Fff D 40 D 1 Al Al r44 a 38 38 38 o 0 0 q0 � d =TT o o Q o 3 v �JF- A2 A2 � � w = a a o o U a 38 G A2 38 COED 8 38 03 38 3 F A8 F OL a UJ M CV Al Al Al LL co G Q 01 N U � dS ° W MCI LU Q o0N,p3� z IL °'na 5 7 8 Z D ZZ 0 0 � (f) Z Ln C) CD 0-1 rx W cr) m W w 0 � LlW DATE: 11/15/2023 SHEET TITLE: LIGHTING PLAN- MAIN LIGHTING PLAN - MAIN SCALE: 1/4" = 1'-0" N SHEET NO. El .01 COP—T 2023,ROBISON ENGirvEENNG,INC, BBENEAR F:\1131-003 JJST POKE IN SNOxWiSN,wA\DK\E3.W POKERDC 04-28-2023 12:24 GENERAL NOTES 1. EMERGENCY EGRESS LIGHTING: TBD. 2. REFER TO SERIES E3.00 DRAWINGS FOR ELECTRICAL AND PANEL LAYOUT. 3. SEE SHEET E1.00 FOR LUMINAIRE SCHEDULE AND LIGHTING NOTES. FLAG NOTES o z N 1. EXIT SIGNS: PROVIDE UNSWITCHED HOT. IN ADDITION TO N w STANDARD HIGH LEVEL EXIT SIGNS, PROVIDE LOW LEVEL EXIT a SIGNS IN ALL INTERIOR CORRIDORS OF GROUP R, DIVISION I 5 (6.7 T (7.5 8 OCCUPANCIES AS INDICATED ON PLAN. (TYP) (IBC 1013.2) w w a o 2. PROVIDE TAMPER RESISTANT LIGHTING CONTROLS. (TYP) a > o 0 z Egress Photometric S.T.. ® II II ® O Schedule OF`ly4SN I O ule ° '�`` ti°gm 13 S 10.5 ched AVERAGE 23.63 FOOT-CANDLES 209 9.7 5.9 16.9 O 17.0 6.1 10.1 204 O MAXIMUM 64.5 o`a��CNA \ 23 FOOT-CANDLES �OOO°1°1,15� Ion MINIMUM .2 FOOT-CANDLES 10.6 0 MINIMUM TO MAXIMUM .10 O O O O FC RATIO 6 9 MAXIMUM TO MINIMUM 10.45 FC RATIO ROTOR' AVERAGE TO MINIMUM 3.83 ENGINEERING,INC FC RATIO 1nmNA .s11 E 2 O NNJl000WA9B0, 36 LY R0636b33E3m REIPROJECTN0.:9fi2020 O D D CONTACT P-ROC-EAD O O O o o�' m m N 6.4 0 0 0 o w U a in w a 6.9 4.6 4.0 6.9 5.5 4.0 7.0 10.2 18.5 O 20.2 o o O 16.5 O O O 0 COED LO 18.4 O 0 n n F F Ell71) O O O (0 w CN LL CO G Q O, o U � 06 a LU 000 Q �p3� Q w z IL ° a 5 7 8 Z L) ZZ o 0 (f) Z Ln 0 CD LJJ cr m W w 0 � LW DATE: 11/15/2023 SHEET TITLE: PHOTOMETRIC PLAN-MAIN PHOTOMETRIC PLAN - MAN SCALE: 1/4" = 1'-0" N SHEET N0. E1 . 11 COP-T 2023.ROBISON ENGNEWN6,INC, BBENEAR F:\1131-003 JJST POKE IN SNOxWiSN,wA\DK\E3.W POKERM 04-28-2023 12:24 11/14/23,3:25 PM waenergycodes.com/print_lroject_summary_form.php?k=aWQ9MjlxMjgmZnZpPTE4JnJlc2VOPTE=&debug=1 IGHTIN 2018 WSEC Compliance Forms for Commercial Buildings including Group R2,R3&R4 over 3 stories and all Rl Administered by:m2023 NEEA,All rights reserved Project Title Edison's Cafe-2018 WSEC For Building Department Use: I Date: NOV 14,2023 2505 Olympic PI zo Project Address Arlington,WA,WA 98223 z N Project&Applicant Sth> o Information Applicant Name Matthew Benzar N w a e Applicant Phone 206-364-3343 � it Applicant Email mbenzar@robisonengineering.com w w For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com a General Occupancy All Commercial General Building Use Type Dining,Restaurant Building Cond.Floor Area 1,912 a New Building or Project Cond.Floor Area 1,912 = Alteration General Project Types Tenant Spaces—Fast Build Out Addition Interior Lighting Lighting Scope Floors Above Grade 1 Lighting Scope Compliance Method Compliance Method 1-General z Lighting Project Description Small Cafe at the bottom of an apartment building. Interior/Exterior �C STF7 Lighting Compliance LPA Calculation Compliance !1' Scope g p Project Type [Interior&parkin�h Interior Luminaire Replacement Scope Compliance Method Adjustment Verification °Fti'p�Am° and Method Tenant Spaces—First Build Out Interior Lighting Building area No Calculation Adjustments selected COMPLIESIR Edison's Cafe-2018 WSEC icNAL \ oo°°°tm� 1 y,23 Lighting Power Calculation TENANT SPACES—FIRST BUILD OUT-INTERIOR LIGHTING Compliance Verification COMPLIES Compliance Method Building area LPA Calculation Adjustment none Interior Lighting Power Allowance-Building Area Building Areas Gross Interior Area(SF) LPA(Watts/SF) Total Watts Allowed Total Proposed Watts Compliance Status by (SF x LPA x l) By Building Area Building Area RO B I SO N Dining-Cafeteria/fast food 1 1,912 1 0.72 1 1,377 1 594 1 COMPLIES ENGINEERING,INC 1e 10THA ew' - Proposed Lighting Power Density LP 206°b63ias Total Watts I CO'Ne'TA'C.TJP'c�ENR.RO'CK"�"AD Watts per Proposed Fixture New or Existing-to- Quantity of Fixtures, Fixture,CLD Total Watts per (#F x WpF) e/A hcation Fixture ID Building Area Remain CLDs or or Linear Linear or PP Luminaires(#F) Luminaire Feet(LF) Foot(WpLF) (LF x (WpF) WpLF) m m cn Individual Fixtures a Direct/indirect Dining-Cafeteria/fast o pant DMF:DC4 C2 S S D 12 FL 0 00 00 40[FINISH]O 00 R DCCX-J food New 11 14 154 0 0 COOPER LIGHTING SOLUTIONS-METALUX(FORMERLY EATON), Dining-Cafeteria/fast 3 cY.3 Of Troffer 24GR-LD5-72-Fl-UNV-L835-CD1-U food New 2 56 112 w = a O � U Q Troffer COOPER-METALUX:14GR LD5 72 Fl UNV L835 CDl U Dining-Cafeteria/fast New 1 56 56 Recessed downlight DMF Lighting,DCCxxxx4D-15F-0000-30-Wxx-R Dining-f Cafeteria/fast New 14 19 262 od Edison's Cafe-2018 WSEC Date Nov 14,2023 Proposed Fixtures Details ENANT SPACES-FIRST BUILD OUT Fixture Type/Application Fixture ID Location in Documents Lamp Type Building Area New or Existing-to-Remain https://waenergycodes.com/print_project_summary_form.php?k=aWQ9MjlxMjgmZnZpPTE4JnJlc2VOPTE=&debug=l 1/2 t ) UJ CV LL oo Q o1 11/14123,3:25 PM waenergycodes.com/print�roject_summary_form.php?k=aWQ9MjlxMjgmZnZpPTE4JnJlc2VOPTE=&debug=1 Q>> N Individual Fixtures U w Direct/indirect pendant DMF:DC4 C2 S S D 12 FL 0 00 00 40[FINISH]O 00 R DCCX-J E 1.00 LED Dinin -Cafet a/fastfoodl New Fixture Description:PENDANT Are these fixtures located within a daylight zone?:No t7() O W m m Do these fixtures require specific application lighting controls?:None required a Troffer COOPER LIGHTING SOLUTIONS-METALUX(FORMERLY EATON),24GR-LD5-72-Fl-UNV-L835-CDl-U E1.00 LED Dining-Cafeteria/fast food New J C F o 0 Fixture Description:BOH 2X4 TROFFER Are these fixtures located within a daylight zone?:No w °o w Do these fixtures require specific application lighting controls?:None required Q o z z 0 Troffer COOPER-METALUX:I4GR LD5 72 Fl UNV L835 CDl U EL00 LED Dining-Cafeteria/fast food New n a Fixture Description:BOH 1X4 TROFFER Are these fixtures located within a daylight zone?:No _ U Do these fixtures require specific application lighting controls?:None required Z Q Z z Recessed downlight DMF Lighting,DCCxxxx4D-15F-0000-30-Wxx-R E.100 LED Dining-Cafeteria/fast food New 0 E O Fixture Description:RECESSED DOWNLIGHT Are these fixtures located within a daylight zone?:No t- i9 Do these fixtures require specific application lighting controls?:None required O (n Z QCD N mw w w c U ��7 a w DATE: 11/15/2023 SHEET TITLE: LIGHTING COMPLIANCE FORMS SHEET NO. El .50 COP—T 2023.ROBISON ENCnEWNO,INC, KGENEAR P:\1131-003 JJST POKE IN SNONWiSH,wA\DK\E3.W POKERDw 04-28-2023 12:24 F- ' SHEET NOTES: I 1. PER 2020 NEC 210.8(B): ALL 50 AMPS OR LESS SINGLE PHASE RECEPTACLES RATED 150V TO GROUND OR LESS&ALL 100 AMPS OR LESS,THREE PHASE RECEPTACLES RATED 150V TO GROUND OR LESS WITHIN KITCHEN,BATHROOM,ROOFTOP,OUTDOORS,SINKS, AND INDOOR WET LOCATIONS SHALL HAVE GFCI PROTECTION AT THE PANEL OR AT THE RECEPTACLE 2 PROVIDE CONDUIT,WIRING,CIRCUITS AND CONNECTIONS AS COORDINATED WITH SECURITY VENDOR FOR FULLY FUNCTIONING SECURITY AND ACCESS CONTROL SYSTEM.COORDINATE WITH L ' SECURITY CONSTRUCTION DOCUMENTS TO IDENTIFY ALL CAMERA LOCATIONS,AT ALL DOORS CALLED OUT BY OWNER. N 3. AMENITY SPACES,OFFICES AND PUBLIC AREAS: ROUGH-INFOR 0 EQUIPMENT,OUTLETS AND APPLIANCES IN AMENITY SPACES BE COORDINATED WITH ARCHITECT.REFER TO ARCHITECTS DRAWINGS Z AND ELEVATIONS. W O > 4. (000NTRACTOR TO COORDINATE DOOR CONTROLS AND CONNECTIONS O_ Of WITH DOOR VENDOR,PROVIDE RACEWAY,CONDUCTORS,POWER U SUPPLY AND TERMINATIONS FOR A FULLY FUNCTIONING SYSTEM. 7 7 (7 8 COORDINATE NTH SECURITY VENDOR FOR MONITORING AND w CONTROL AS NEEDED. d o S. ELECTRICAL CONTRACTOR(EC)TO PROVIDE J-BOX/PULL BOX 50 w NUMBER OF BENDS IN CONDUIT DOES NOT EXCEED CODE REQUIREMENT(360 MAX TOTAL).EC TO FIELD VERIFY LOCATION OF Q ' A-42 J-BOX/PULL BOX.COORDINATE WITH ARCHITECT WHERE ACCESS = #10 117 PANEL IS REQUIRED. 0 A 7 A 9 C FLAG NOTES: ® z O (NOT EVERY FLAG IS USED ON EVERY SHEET) 1. SERVICE RECEPTACLES MUST BE WITHIN 25'OF HVAC EQUIPMENT, OOOpO ST 0000 II 94 II CONTRACTOR RESPONSIBLE TO COORDINATE LOCATION WITH HVAC II II A 12 1.1 1 HOVAIC EQUIPMEO TT FRAMEWORK.MAY MOUNT THE RECEPTACLES ON THE �pF yCA��QOO O 2. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR - g a PRIOR TO INSTALLATION. O A-30 FCU-1 ,5 3. COORDINATE PUMP ROUGH-IN,CONTROLLER LOCATION AND 13 OO 0.73K VA,208V2P2W A-10 CONDUITS FOR PUMP CONTROLS WITH PLUMBING CONTRACTOR. 000�css B-9,11 CONFIRM PUMP HE AND VOLTAGE WITH SUPPLIER. O TONAL71 °oa000000 -23 A-14 A 8 O A-11,13,15 4. COORDINATE FINAL SPECIFICATION WITH KITCHEN DESIGN SUBMITTAL SPEC SHEET. 3/4,.G,3#6,H10G A-16 A-2 4 5. INDOOR UNIT POWERED BY OUTDOOR HEAT PUMP UNIT. 6 rr A-17,19,21 1/2"C,3#10,//10G A-20 3 2 9 FCU-2 ENG��RING,INC ���A-22 FHP,120V - 75 A-24 D D O 16 A-23 7 5 m m cn A_31 5 o000° o a A-26 A-28 � � Y o ❑ HWCP-1 Q w a ERV-1-1 FHP,120V1P2 0 0 ¢ p 1/2HP,1/2HPV2P2W B-17 A 2 A-33,35,37 0 ' -13,15 COED - --- ELECTRICAL KITCHEN EQUIPMENT SCHEDULE ------WH-1 TAG p DESCRIPTION VOLTAGE/PH kW MAKE&MODEL 0.24KVA,120V1P2W A-29 1 WALK-IN COOLER/FREEZER 208V/3 - KOLPAK F O ' 1.1 EVAPORATOR COIL 120V/1 1.44 ROBOT COUPE CL50 ULTRA 1 04 0 00 L-LL- ED 1.4 EVAPORATOR COIL 120V/1 1.22 HOSHIZAKI KM-520MAJ w CV ---- IN El G 8 MULTICOOK OVEN 208V/3 13.9 ALTO-SHAAM VMC-H4H 0. 9 COMBI OVEN 208V/1 6.77 ALTO-SHAAM CTX4-10EVH / \ j o I O 16 REF SANDWICH TABLE 115V/1 0.747 TSSU-60-12-HC \y� > co ' mo 20 FOOD PROCESSOR 120V/1 0.84 ROBOT COUPE R2CLRDICE -" O §rn m pJ 23 20 OT FOOD MIXER 120V/1 0.39 HOBART HL200-1STD J _ m '0 O ui N 35 VENTLESS DISHWASHER 208V/3 2.62 CHAMPION DH-6000-VHR Q Q !3 z 50 GLASS DOOR MERCHANDISER 115V/1 0.839 GDM-49HC-TSLO1 4 J 0 5 7 — 55 HIGH SPEED OVEN 208V/1 6.5 UNOX XASW-03HS-EDDS _U ' 56 2 DOOR UC REFRIGERATOR 115V/1 0.345 HOSHIZAKI UR4 78B Z ICI Z_ 57 COFFEE BREWER 120V/1 1.37 BUNN 12950.0360 0 _t- �O//) 65 POINT OF SALES 120V/1 1,759 STRUCTURAL CONCEPTS C3Z3667 O V Z 68 ESPRESSO MACHINE 120V/1 1.7 CIMBALI M26 TE RE DT/2 F5 CD N /'1A w w Lu w 69 UC ICE MACHINE 115V/1 0.345 SCOTSMAN CU0415MA-1 Z 71 UC REFRIGERATOR 115V/1 0.253 TURBO AIR TUR-28SD-N-L w Z 72 ESPRESSO GRINDER 11OV/1 0.600 ROSITOBISANI F64E d w' ' 75 AMBIENT DISPLAY CASE 120V/1 0.048 STRUCTURAL CONCEPTS CG2830 DATE: 11/15/2023 76 REF GRAB&GO CASE 120V/1 1.05 STRUCTURAL CONCEPTS C033R-U 94 OPEN AIR REF MERCHANDISER 120V/1 1.2 STRUCTURAL CONCEPTS 83424 SHEET TITLE: POWER PLAN- POWER PLAN - MAN 1 MAIN SCALE: 1/4" = 1'-0" N SHEET N0 E3.00 COP—T 2023.RNEKON ENGINEEPoNC.INC KEENEAR F:\1131-003 JOST POKE IN SNOHOMISH,wA\DK\E3.W POKERNiN 04-28-2023 12:24 SHEET NOTES: 1. PER 2020 NEC 210.8(B): ALL 50 AMPS OR LESS SINGLE PHASE RECEPTACLES RATED 150V TO GROUND OR LESS&ALL 100 AMPS OR LESS,THREE PHASE RECEPTACLES RATED 150V TO GROUND OR LESS WITHIN KITCHEN,BATHROOM,ROOFTOP,OUTDOORS,SINKS, AND INDOOR WET LOCATIONS SHALL HAVE GFCI PROTECTION AT THE PANEL OR AT THE RECEPTACLE 2. PROVIDE CONDUIT,WIRING,CIRCUITS AND CONNECTIONS AS COORDINATED WITH SECURITY VENDOR FOR FULLY FUNCTIONING SECURITY AND ACCESS CONTROL SYSTEM.COORDINATE WITH SECURITY CONSTRUCTION DOCUMENTS TO IDENTIFY ALL CAMERA LOCATIONS,AT ALL DOORS CALLED OUT BY OWNER. N 3, AMENITY SPACES,OFFICES AND PUBLIC AREAS: ROUGH-INFOR 0 EQUIPMENT,OUTLETS AND APPLIANCES IN AMENITY SPACES BE COORDINATED WITH ARCHITECT.REFER TO ARCHITECTS DRAWINGS Z N AND ELEVATIONS. W O N P: W 4. CONTRACTOR TO COORDINATE DOOR CONTROLS AND CONNECTIONS Q_ EC WITH DOOR VENDOR.PROVIDE RACEWAY,CONDUCTORS,POWER K SUPPLY AND TERMINATIONS FOR A FULLY FUNCTIONING SYSTEM. :E U COORDINATE WITH SECURITY VENDOR FOR MONITORING AND w W O CONTROL AS NEEDED. CL 0 O 5. ELECTRICAL CONTRACTOR(EC)TO PROVIDE BOX/PULL BOX SO NUMBER OF BENDS IN CONDUIT DOES NOT EXX CEED CODE REQUIREMENT(360 MAX TOTAL).EC TO FIELD VERIFY LOCATION OF Q J-BOX/PULL BOX.COORDINATE WITH ARCHITECT WHERE ACCESS = PANEL IS REQUIRED. O FLAG NOTES: ® f Z (NOT EVERY FLAG IS USED ON EVERY SHEET) 1. SERVICE RECEPTACLES MUST BE WITHIN 25'OF HVAC EQUIPMENT. OOOpO ST 0000 CONTRACTOR RESPONSIBLE TO COORDINATE LOCATION WITH HVAC HQIC CONTRACTOR F MOUNT THE RECEPTACLES ON THE OF VA EQUIPMENT FRAMEWORK. yCA��OOO 2. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR - g 0 PRIOR TO INSTALLATION. p 3. COORDINATE PUMP ROUGH-IN,CONTROLLER LOCATION AND O ' o� 00O0 CONDUITS FOR PUMP CONTROLS WITH PLUMBING CONTRACTOR. O� �AL.. ($' CONFIRM PUMP HP AND VOLTAGE WITH SUPPLIER. `�O'�`/ 4. COORDINATE FINAL SPECIFICATION WITH KITCHEN DESIGN SUBMITTAL �aDo SPEC SHEET. 5. INDOOR UNIT POWERED BY OUTDOOR HEAT PUMP UNIT. ROBISON ENGINEERING,INC I WIWTHA ew'SJIILISI �vzos�ais<3 - REIPNOJECTNO CONTACT PETERROC—AID HP-1 4.83KVA,208V2P2W B-1,3 2 W ECI o 0 3 HP-2 Z Z > 3 � Y o U � 3.16KVA,208V2P2W a U) w a w T a 8-5,7 0 o U a 0 2 3 ELECTRICAL KITCHEN EQUIPMENT SCHEDULE TAG R DESCRIPTION VOLTAGE/PH kW MAKE&MODEL 1 WALK-IN COOLER/FREEZER 208V/3 - KOLPAK 1.1 EVAPORATOR COIL 120V/1 1.44 ROBOT COUPE CL50 ULTRA 1 1.4 EVAPORATOR COIL 120V/1 1.22 HOSHIZAKI KM-520MAJ w CV LL 00 8 MULTICOOK OVEN 208V/3 13.9 ALTO-SHAAM VMC-H4H p. 9 COMBI OVEN 208V/1 6.77 ALTO-SHAAM CTX4-10EVH U j o > w 16 REF SANDWICH TABLE 115V/1 0.747 TSSU-60-12-HC co 20 FOOD PROCESSOR 120V/1 0.84 ROBOT COUPE R2CLRDICE 05 _O W m 23 20 OT FOOD MIXER 120V/1 0.39 HOBART HL200-1STD mwo N 35 VENTLESS DISHWASHER 208V/3 2.62 CHAMPION DH-6000-VHR Q Q 3 z 50 GLASS DOOR MERCHANDISER 115V/1 0.839 GDM-49HC-TSLO1 J 2a 00 55 HIGH SPEED OVEN 208V/1 6.5 UNOX XASW-03HS-EDDS _U7 56 2 DOOR UC REFRIGERATOR 115V/1 0.345 HOSHIZAKI UR48B Z ICI Z_ 57 COFFEE BREWER 120V/1 1.37 1 BUNN 12950.0360 0 _t- �O//�� Lo 65 POINT OF SALES 120V/1 1,759 STRUCTURAL CONCEPTS C3Z3667 O V Z 68 ESPRESSO MACHINE 120V/1 1.7 CIMBALI M26 TE RE DT/2 0 CD N /'� w w w 69 UC ICE MACHINE 115V/1 0.345 SCOTSMAN CU0415MA-1 Z 71 UC REFRIGERATOR 115V/1 0.253 TURBO AIR TUR-28SD-N-L w 72 ESPRESSO GRINDER 110V/1 0.600 ROSITOBISANI F64E a a W / 75 AMBIENT DISPLAY CASE 120V/1 0.048 STRUCTURAL CONCEPTS CG2830 DATE: 11/15/2023 76 REF GRAB&GO CASE 120V/1 1.05 STRUCTURAL CONCEPTS C033R-U 94 OPEN AIR REF MERCHANDISER 1 120V/1 1 1.2 STRUCTURAL CONCEPTS 83424 SHEET TITLE: POWER PLAN- POWER PLAN - ROOF ROOF SCALE: 1/4" = 1'-0" N SHEET N0 3.01 CO-IIOHT 2023,ROBISON ENOINEEPoNO,INC BBENEAR F:\1131-003 JOST POKE IN SNOHOMISH,WA\DWO\E3.W POKRDNN 04-28-202312:24 COORDINATION AND ARC FLASH STUDIES: GROUNDING NOTES AND REQUIREMENTS: SHEET NOTES: (FOR E5.00) Panel ROOM VOLTS 208Y/120V 3P 4W AIC 22,000 Panel ROOM VOLTS 201 3P 4W AIC 2$000 MOUNTING FLUSH BUS AMPS 200 MAIN BKR MILD MOUNTING FLUSH BUS AMPS 200 MAIN BKR MLO IMMEDIATELY UPON SELECTION OF ACTUAL EQUIPMENT BEING PROVIDED THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE A. CONTRACTOR TO OBTAIN UTILITY APPROVAL OF ALL SERVICE A FED FROM XFMR NEUTRAL 100% LUGS STANDARD B FED FROM XFMR NEUTRAL 100% LUGS STANDARD FOR THE PROJECT,THE ELECTRICAL CONTRACTOR SHALL PERFORM AN GENERAL CONTRACTOR,POWER COMPANY,PHONE COMPANY, AND METERING EQUIPMENT PRIOR TO ORDERING. NOTE NOTE ARC FLASH ANALYSIS AND COORDINATION STUDY ON THE STANDBY INTERNET COMPANY, CABLE TV COMPANY, AND THE SATELLITE DISTRIBUTION BASED ON ACTUAL EQUIPMENT TO BE PROVIDED, TV COMPANY TO ENSURE REQUIRED GROUNDING IS INSTALLED B. DISTRIBUTION SYSTEM AS DESIGNED IS FULLY RATED. GKT CKT LOAD CKT CUT LOAD CKT CUT LOAD CKT CKT LOAD CONDUCTOR TYPES/SIZES/LENGTHS,ETC.COORDINATION SHALL BE FOR EACH SYSTEM. CONTRACTOR WILL BE RESPONSIBLE FOR ENGINEERING IF SERIES BKR KVA CIRCUIT DESCRIPTION BKR KVA CIRCUIT DESCRIPTION BKR KVA CIRCUIT DESCRIPTION BKR KVA CIRCUIT DESCRIPTION CONFIRMED BASED ON FAULT NUMBERS SHOWN ON THIS DRAWING. RATED SYSTEMS ARE SUBMITTED,THE SUBMITTED SYSTEM SHALL 1 20/3 1.73 WALK IN COOLER/FREEZER a 2 30/3 6.5 HIGH SPEED OVEN 1 40/2 4.83 HI a 2 20/1 0 SPARE STUDIES SUBMITTED SHALL BE STAMPED BY A PROFESSIONAL THIS SHALL BE DONE PRIOR TO AND DURING INSTALLATION OF MEET NEC 240.86(B)REQUIREMENTS FOR TESTED COMBINATIONS, 3 1 b 4 1 3 b 4 20/1 0 SPARE ELECTRICAL ENGINEER HOLDING A CURRENT LICENSE FROM THE STATE FOUNDATION RE-BAR AND CONTINUE DURING THE CONSTRUCTION AND SHALL NOT BE USED IF MOTOR CONTRIBUTION EXCEEDS 5 1 c 6 1 5 25/2 3.16 HP-2 c 6 20/1 0 SPARE OF WA. PHASES, TO ENSURE EACH SYSTEM HAS ITS REQUIRED LIMITS PER 240.86(C).NEC 110.22 MARKING REQUIREMENTS 7 20/1 1.44 EVAPORATOR COIL a 8 20/1 0.345 2 DR UC FRIDGE 7 1 a 8 20/1 0 SPARE PRELIMINARY ARC FLASH AND COORDINAPON STUDIES ARE TO BE GROUNDING INSTALLED FOR PROPER OPERATION OF THE SYSTEM. MUST BE MET. � 9 20/1 1.44 EVAPORATOR COIL b 10 20/1 1.37 COFFEE BREWER 9 15/2 0.729 FCU-1 b 10 20/1 0 SPARE SUBMITTED WITH THE SUBMITTALS FOR THE PROTECTIVE DEVICES, C. PROVIDE PERMANENT WARNING LABELS FOR ARC FLASH AND Z 11 50/3 13 MULTI COOK OVEN c 12 20/1 1.76 POS 11 1 c 12 20/1 0 SPARE PANELBOARDS,SWITCHBOARDS,AND OTHER ELECTRICAL EQPT. PPE REQUIREMENTS FOR THE SERVICE EQUIPMENT AND PANELS. o 13 1 a 14 20/1 0.253 UC ICE MACHINE 13 15/2 2.35 ERV-1-1 a 14 20/1 0 SPARE THE ELECTRICAL CONTRACTOR SHALL COORDINATE AND PROVIDE ZU VI b 16 20 1 1.7 ESPRESSO MACHINE 15 20 1 0 SPARE THE ELECTRICAL CONTRACTOR SHALL SUBMIT THE STAMPED AND WHAT IS REQUIRED TO DO THE FOLLOWING 15 : w / b 16 / SIGNED ARC FLASH AND COORDINATION STUDY TO THE AHJ AS N w 17 30/3 6.77 COMBI OVEN c 18 20/1 0.253 UC FRIDGE 17 20/1 0.1 HIc 18 20/1 0 SPARE REQUIRED. 1. FOOTING GROUND RE-BAR COMES UP IN THE ELECTRICAL 19 a 20 20/1 0.8 COFFEE GRINDER 19 20/1 0.18 RECEPTACLE a 20 20/1 0 SPARE OD ROOM AND THE RE-BAR IS SNUGLY SECURED TO THE U 21 b 22 20 1 1 0.6 COFFEE GRINDER 21 20 0 SPARE b 22 20 1 0 SPARE THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL . / / / PERMANENT LABELS INDICATING ARC FLASH HAZARD RISK CATEGORIES FOOTING RE-BAR PER OWNER DETAIL w w 23 20/1 0.84 REF SANDWICH TABLE c 24 20/1 1..048 PASTRY DISPLAY CASE 23 20/1 0 SPARE c 24 20/1 0 SPARE DI ALL DISTRIBUTION POINTS(SWITCHBOARDS.COMPLY OARDS, PA 7 2. THE MSB GROUNDING TIES TO THE FOOTING RE-BAR, d 25 20/1 0.39 FOOD PROCESSOR a 26 20/1 1.76 REF GRAB STAND 25 20/1 0 SPARE a 26 20/1 0 SPARE DISCONNECT SWITCHES,ETC). LABELS SHALL COMPLY WITH NFPA 70E. COUNTERPOISE,BUILDING STEEL, AND WATER PIPING. 27 20/1 0.39 FOOD MIXER b 28 20/1 1.78 POS 27 20/1 0 SPARE b 28 20/1 0 SPARE FLAG NOTES: (FOR E5.00) 29 20/1 0.24 WH-1 c 30 20/1 1.2 OPEN AIR MERCHANDISER 29 20/1 0 SPARE c 30 20/1 0 SPARE 3. THE GROUND WIRE FOR THE COUNTERPOISE SHALL BE 4 31 20/1 0.84 GLASS DOOR MERCHANDISER a 32 20/1 0 SPARE 31 20/1 0 SPARE a 32 20/1 0 ARE STRANDED, INSULATED WIRE IN CONDUIT UNTIL IT REACHES o 33 20/3 2.62 VENTLESS DISHWASHER b 34 20/1 0 SPARE 33 20/1 0 SPARE b 34 20/1 0 SPARE THE FIRST BAR OF THE COUNTERPOISE.BETWEEN THE 1. EXISTING ELECTRICAL EQUIPMENT. 35 1 c 36 20/1 0 SPARE 35 20/1 0 SPARE c 36 20/1 0 SPARE COUNTERPOISE BARS IT SHALL BE A STRANDED BARE COPPER WIRE. 37 1 a 38 20/1 0.332 LIGHTING 37 20/1 0 SPARE a 38 20/1 0 SPARE f Z 39 20/1 0 SPARE b 40 20/1 0.238 UGHTING 39 20/1 0 SPARE b 40 20/1 0 SPARE 41 20/1 0 SPARE c 42 20/1 1.26 RECEPTACLE 41 20/1 0 SPARE c 42 20/1 0 SPARE CON �OOOppOOO CALL CONN CALL CONN CALL CONN CALL EVA GENERAL FEEDER SCHEDULE KVA KVA KVA KVA KVA KVA KVA KVA V OFVy4SN LIGHTING 0.569 0.712 (125%) MOTORS 0.24 0.24 (100%) LARGEST RECEPTACLES 0.18 0.18 (50%>10) LARGEST RECEPTACLES 4.78 4.78 (50%>10) MOTOR 4.83 1.21 (25%) HEATING 2.35 2.35 (100%) FEEDER CONDUIT AND FEEDER FEEDING THESE DEVICES m p H'I 0.24 0.06 (25%) KITCHEN MOTOR MOTORS 8.82 8.82 (100%) COOLING 2.35 0 (100 p EQUIPMENT 43.7 28.4 (65%) 200 2-1/2"C,3#250kcmil AL,#250kcmil AL N,#2 AL G A, B OS IS p TOTAL LOAD 12.6 TOTAL LOAD 34.2 BALANCED 3-PHASE ADD (2)2-1/2"C,3#25Okil AL,#250kil AL N,#1/0 XFMR \C' 10 ' BALANCED 3-PHASE P A QgSp 3 CNAL LOAD 95 A X8 A A cm cm L G �O �Fj'23 PHASE A 95.7% PHASE B 137 SIZING METHOD: COPPER,60'C#12 THROUGH#1,75 ODOOD'C 1/0 AND ABOVE 1l� PHASE B 108E PHASE C 54% PHASE C 95.7% FEEDER SCHEDULE NOTES: CONDUIT FILL: * FOR CONDUIT SIZES 1-1/2"AND BELOW,FILL IS BASED ON EMT. - * FOR CONDUIT SIZES 2"AND ABOVE,FILL IS BASED ON SCHEDULE 40 PVC. a,s IN LOCATIONS APPROVED FOR THE PURPOSE, CONTRACTOR MAY USE MC CABLE. IN LOCATIONS APPROVED FOR THE PURPOSE CONTRACTOR MAY USE OTHER CONDUIT TYPES,INCLUDING RMC, FMC AND LFMC. CONTRACTOR REQUIRED TO ENSURE CONDUIT FILL DOES NOT EXCEED 40%. R0131SON CONTRACTOR RESPONSIBLE TO ENSURE TERMINATION/LUG CAPACITY FOR ALL SCHEDULED FEEDERS. ENGINEERING,INC XHHW/THHN/THWN SHALL BE USED FOR INSULATION OF THE CONDUCTOR. mi_HAVEw.SUrE3C2 LYWO NOD,MW36 .S.33E3T¢ RCONTACT ECEN0.:9fi2020 m ED V1 OL D_ x Of 0 0 o w w 0 3 Y o U C a n w a s w x a LEVEL 02 M UJ N A LL cp 2208Y/0 0001 i0V 3P 4W 2 20 0001 i0V 3P 4W 01 N 0 �x Fw 0.6 O 3 M XFMR EXISTING 208Y/120V 3P 4W 1 ¢3 m BUILDING W .� oo1 DISTRIBUTION Q Q n: El E GEAR zo IL OIL L) Z Zz 0 0 0 ICI � m W LEVEL 01 LJJ N W Ll0 W DATE: 11/15/2023 SHEET TITLE: ONE-LINE DIAGRAM SHEET NO. E5.00 CO-TIGHT 2022,RWISON ENawEEPoNa,INC MSIEINHE C.\TRESOURCE`WER\STBNKE ILAt4NS TEMPLATES\APARIMENT 30%42\E500 ONE MNI IO-0Y2022 10:41 GENERAL NOTES ABBREVIATIONS SYMBOLS ACU AIR CONDITIONING UNIT EQUIPMENT DUCTWORK AFF ABOVE FINISHED FLOOR EF-1 TYPICAL EQUIPMENT DESIGNATION GENERAL NOTES-MECHANICAL 4. APPROVALS:MECHANICAL AND PLUMBING EQUIPMENT SHALL BE AHJ AUTHORITY HAVING - 18x12 DUCT(1ST FIGURE=SIDE SHOWN,2ND APPROVED FOR INSTALLATION IN THE PROJECT LOCATION AND SHALL 4. ROUND TEES AND LATERALS:CONICAL TEE PER SMACNA HVAC FIG 3-5;DO JURISDICTION (EXHAUST FAN SHOWN) -" FIGURE=SIDE NOT SHOWN) 1. REFERENCE TO RELATED WORK"REF"INDICATIONS DENOTE WORK HAVE ALL CERTIFICATIONS AND RATINGS TO MEET ALL ENERGY, NOT USE STRAIGHT TEE;DO NOT USE CONICAL SADDLE TAP FOR EXPOSED AHU AIR HANDLING UNIT DS Up DOWN COVERED ELSEWHERE(ARCHITECTURAL,STRUCTURAL,CIVIL, POLLUTION,ENVIRONMENTAL,SEISMIC,ETC.CODES AND REGULATIONS. DUCTWORK IN FINISHED SPACES.90-DEGREE TEE WITH OVAL TO ROUND SDD BACKDRAFT DAMPER DUCT SMOKE DETECTOR DUCT SECTION,POSITIVE PRESSURE ELECTRICAL,LANDSCAPE,OR KITCHEN),OR ITEM BASED ON A SPECIFIC THE CONTRACTOR SHALL COORDINATE WITH HIS MANUFACTURE TAP,LATERAL,AND 45-DEGREE RECTANGULAR LEAD-IN PER SMACNA HVAC BHP BRAKE HORSEPOWER MANUFACTURER'S DIMENSIONS(VERIFY). SUPPLIERS AND SHALL INCLUDE ALL COSTS REQUIRED TO MEET THESE FIG 34. BTUH BRITISH THERMAL UNIT ROOM THERMOSTAT OR UP DOWN REQUIREMENTS IN HIS BID. PER HOUR DUCT SECTION,NEGATIVE PRESSURE (D TEMPERATURE TRANSMITTER 2. ELECTRICAL CHARACTERISTICS:REFER TO ELECTRICAL DRAWINGS FOR 5. RECTANGULAR ELBOWS AND OFFSETS:FULL RADIUS WHERE SPACE C COMMON ELECTRICAL CHARACTERISTICS(VOLTAGES,ETC.OF MECHANICAL 5. FIRE PROTECTION:CONTRACTOR SHALL PROVIDE A FULLY DESIGNED FIRE PERMITS,R/W=1.5;OTHERWISE USE SQUARE CORNER ELBOW WITH CAP CAPACITY UP DOWN m EQUIPMENT,UNLESS OTHERWISE INDICATED. PROTECTION SPRINKLER SYSTEM IN COMPLIANCE WITH NFPA AND LOCAL TURNING VANES. CC COOLING COIL ROOM HUMIDISTAT OR HUMIDITY yy�l z O TRANSMITTER \I� ROUND DUCT SECTION O CODES.PROVIDE DESIGN,PERMITS,MATERIALS,INSTALLATION,TESTING CD CEILING DIFFUSER TTT z 0 3. CODES:COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE AND ALL OTHER FOR A FULLY OPERATIONAL SYSTEM.LOCATION OF ALL 6. RECTANGULAR DIVIDED FLOW FITTINGS:USE GENERALLY,EXCEPT CFM CUBIC FEET PER MINUTE UP UP UP o® CARBON MONOXIDE SENSOR 5; PER THE APPLICABLE BUILDING,MECHANICAL,ENERGY,PLUMBING,FIRE, PIPING TO BE COORDINATED WITH OTHER TRADES. BRANCHES TO TERMINALS;SMACNA HVAC FIG 2-5,TYPES 1,2,4A,AND 48. CLG CEILING,COOLING DUCT PENETRATION THRU FLOOR OR 4 m AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL AHJ. DO NOT USE TYPE 3. CO CLEANOUT SMOKE DETECTOR ROOF 6. FIREPLACES:COORDINATE WITH THE GENERAL CONTRACTOR TO COMB COMBUSTION TERMINALS T N 4. PREPARE AND SUBMIT FOR REVIEW A SHOP DRAWING BASED ON FINAL DETERMINE GAS FIREPLACE FLUE AND COMBUSTION AIR DUCTWORK T TURNING VANES:H.E.P.MANUFACTURER OR APPROVED HIGH EFFICIENCY CONT CONTINUE,CONTROL rDIFFUSER/GRILLE TYPE,AND NUMBER ) VOLUME DAMPER o STRUCTURAL SHOP DRAWINGS FOR LOCATING AND ROUTING ALL REQUIREMENTS PRIOR TO BIDDING. PROFILE AIRFOIL TYPE FOR RECTANGULAR SQUARE THROAT ELBOWS. COP COEFFICIENT OF C0.12x12 OR CD-1 OR SIZE DUCTWORK,DAMPERS,EQUIPMENT,PIPING,ETC. ACOUSTICAL TYPE FOR RETURN AIR MITERED ELBOWS. PERFORMANCE 400 400 DESIGN CFM(WHERE APPLICABLE) FSD FIRE/SMOKE DAMPER(1=HORIZ A. COORDINATE FLOOR AND BEAM PENETRATIONS WITH STRUCTURAL. PIPING NOTES CWS CHILLED/CONDENSER WATER CEILING DIFFUSER(FLOW ARROWS _ FSD DUCT,-<>=VERT DUCT),2-HR RATED, B. COORDINATE FINAL LOCATION AND ROUTING WITH CEILING,LIGHTS, 8. TAKEOFFS TO OPENINGS:CONICAL TYPE WITH VOLUME DAMPER FOR SUPPLY SHOWN FOR NON SYMMETRICAL LION <>- WALLS,FIRE SPRINKLER PIPING,AND OTHER TRADES WORK. 1. DISASSEMBLY PROVISIONS:PROVIDE UNIONS OR FLANGES AT PIPING ROUND DUCT BRANCHES PER SMACNA HVAC FIG 2-6,MINIMUM INLET CWR CHILLED/CONDENSER WATER AIRFLOW) TFD FIRE DAMPER(1=HORIZ DUCT,- - C. INCLUDE ADDITIONAL OFFSETS,ELBOWS,ROUTING,EQUIVALENT DUCT CONNECTIONS TO EQUIPMENT,COILS,TRAPS,CONTROL VALVES,AND DIAMETER 2 INCHES LARGER THAN DUCT SIZE.45 DEGREE ENTRY FITTING RETURN T M- C. VERT DUCT),2-HR RATED,LION EXCHANGE,RELOCATING,ETC.AS REQUIRED FOR A COMPLETE OTHER COMPONENTS TO ALLOW DISASSEMBLY FOR MAINTENANCE. FOR RECTANGULAR DUCT BRANCHES PER SMACNA HVAC FIG 2-6. D DIAMETER ICJ CEILING RETURN/EXHAUST GRILLE _ OPERATING MECHANICAL SYSTEM. DB DRY BULB,DECIBEL D. PROVIDE SHOP DRAWINGS AT NO ADDITIONAL COST TO THE OWNER. 2. REDUCERS:PROVIDE AS REQUIRED FROM LINE PIPE SIZE TO EQUIPMENT, 9. FLEXIBLE CONNECTIONS:PROVIDE AT EACH DUCT CONNECTION TO FANS, DIM DIMENSION I LINEAR DIFFUSER,CEILING OR WALL TRAP,COIL,AND CONTROL VALVE CONNECTION SIZES. PACKAGED HVAC EQUIPMENT,EXTERNALLY ISOLATED AIR HANDLING DISCH DISCHARGE O MOUNTED(FLOW ARROWS SHOWN 90°ELBOW,RID OR R/W=1.5 O❑ODOOp 5. MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE EXACT UNITS,FAN COIL UNITS,AND SIMILAR EQUIPMENT.EXCEPTION:EQUIPMENT ON DOWN �p 00 LOCATION OF ALL MECHANICAL EQUIPMENT WITHIN THE STRUCTURE. 3. OFFSETS:PROVIDE FOR BRANCH LINES TO EQUIPMENT. IN CORRIDOR CEILING SPACES WHERE FIRE RATING IS REQUIRED. EA EXHAUST AIR 4FOR NON SYMMETRICAL AIRFLOW) 00"PIP, '�..,V�.A......T, 0 EAT ENTERING AIR TEMPERATURE SQUARE CORNER ELBOW WITH 00 6. ACCESS DOORS:COORDINATE WITH ARCHITECT AND LOCATE ALL ACCESS 4. DIELECTRIC UNIONS:PROVIDE AT CONNECTIONS OF DISSIMILAR PIPE. HVAC NOTES EER ENERGY EFFICIENCY RATIO WALL SUPPLY GRILLE(SG) 0 ❑ TURNING VANES DOORS ON SHOP DRAWINGS PRIOR TO BEGINNING OF CONSTRUCTION. EF EXHAUST FAN :h ❑ i ❑ ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE FIRE RATED.VERIFY 5. REFRIGERANT PIPING:PROVIDE SIZING&INSTALLATION IN STRICT 1. ATTACHMENTS:AIR DISTRIBUTION OUTLETS AND LOUVERS SHALL HAVE EFF EFFICIENCY WALL RETURN/EXHAUST GRILLE(RG, ACCESS DOOR LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. ALL REQUIRED ACCESSORIES AND ATTACHMENTS FOR A COMPLETE EG EXHAUST GRILLE V EG) 90°TAKE-OFF OR TEE BIDDING. CONNECTION TO THE SPECIFIC TYPE OF STRUCTURE THAT THEY ARE ELEC ELECTRIC DO L \ O' TRANSFER GRILLE DUCT /�p MO EtT>�O 6. CONDENSATE DRAIN:PROVIDE A P-TRAP FOR EACH HVAC UNIT BEING ATTACHED TO.THIS INCLUDES,BUT IS NOT LIMITED TO,EXTERIOR ESP EXTERNAL STATIC PRESSURE -1�3 -� CONNECTED,WALL MOUNTED W/ � 90°CONICAL TAKE-OFF Opp❑❑ 7. RATED PENETRATION:DUCT PENETRATIONS THROUGH RATED CONDENSATE PAN WITH PLUG TEES FOR CLEANING.CONDENSATE DRAINS BRICKS,GWB WALLS,GWB CEILING,ETC. EXH EXHAUST 50 OPTIONAL CFM SHOWN 5� ENCLOSURES SHALL BE FIRE/SMOKE DAMPERED PER THE LATEST EDITION SHALL BE DISCHARGED TO AN INDIRECT WASTE OR OUTSIDE. EXT EXTERIOR,EXTERNAL 1 TRANSFER GRILLE,CEILING MOUNTED OF THE UNDERWRITERS LABORATORIES(UL)FIRE RESISTANCE WITH 2. DUCTWORK DUCTWORK SHALL BE SMOOTH SHEET METAL(CLASS-1). F FAHRENHEIT HOURLY RATINGS FOR THROUGH-PENETRATION FIRE STOPS SYSTEM INSULATION/LINING NOTES DUCTWORK THROUGH FIRE RATED STRUCTURE AND FLOOR SHALL BE MIN. FCU FAN COIL UNIT �/� I WITH FULL-SIZED D LINED DUCT _L 45°LATERAL TAKE-OFF VOLUME#2,OR SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE 26 GA.STEEL.MAXIMUM LENGTH OF FLEXIBLE DUCTS SHALL BE 5'-0", FLR FLOOR CONNECTION , MANUFACTURER'S UL LISTINGS(3M OR EQUIVALENT).DETERMINE 1. ENERGY CODE:AS A MINIMUM,COMPLY WITH THICKNESSES AND TYPES UNLESS OTHERWISE NOTED ON DRAWINGS.DUCTWORK SIZES SHOWN FPM FEET PER MINUTE PIPING TRANSITION OR REDUCER(FOT=FLAT REQUIREMENTS WITH GENERAL CONTRACTOR PRIOR TO BID. LISTED IN ENERGY CODE ENFORCED BY AHJ. ARE INSIDE CLEAR DIMENSIONS. FPS FEET PER SECOND CD CONDENSATE DRAINAGE ON TOP,FOB=FLAT ON BOTTOM) FSD FIREISMOKE DAMPER d' .. 8. EXHAUST OUTLETS:SOURCE-SPECIFIC FANS SHALL BE VENTED TO 2. EXTENT OF INTERNAL DUCT LINING: 3. VOLUME DAMPERS:PROVIDE AN ACCESSIBLE MANUAL VOLUME DAMPER G GAS G NATURAL GAS-STD.PRESSURE OUTDOORS WITH A MINIMUM&CLEARANCE BETWEEN VENT OUTLETS AND A. GRILLE AND DIFFUSER BOXES AND BOOTS. FOR EACH SUPPLY,RETURN,OSA,AND EXHAUST OPENING,LOCATED AS GAL GALLONS MPG NATURAL GAS-MEDIUM PRESSURE WYE FITTING D O���ON BUILDING OPENINGS,AND 10'MINIMUM BETWEEN VENT OUTLETS AND B. TRANSFER DUCTS. FAR UPSTREAM AS POSSIBLE FROM THE OPENING.PROVIDE A MANUAL GPM GALLONS PER MINUTE :1 PIPE CAP R MECHANICAL AIR INTAKES. C. THE FIRST 10 FEET OF SUPPLY AND RETURN DUCTWORK FROM THE VOLUME DAMPER FOR BRANCH MAINS SERVING MORE THAN ONE GIRD GRILLES,REGISTERS, ENGINEERING,INC AIR HANDLER. OPENING.VOLUME DAMPERS IN NON-ACCESSIBLE CEILINGS SHALL HAVE A DIFFUSERS PIPE PLUG 90°RECTANGULAR TAKE-OFF WITH 45° �smi 4mrvavewsmeaoz 9. ROOF PENETRATIONS:SEE ARCHITECTURAL DRAWINGS FOR ROOF CAP, CONTROL ARM EXTENDED TO AN ACCESSIBLE LOCATION. GWB GYPSUM WALLBOARD TAPER w" UNION zossrw,+3e3m ROOF CURB,ROOF DRAIN,AND VTR DETAILS. 3. EXTENT OF EXTERNAL DUCT INSULATION: HD HEAD R°=r^e= 420 A. SUPPLY AND RETURN AIR IN UNCONDITIONED SPACES,MECHANICAL 4. SEISMIC:PROVIDE SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT, HORIZ HORIZONTAL FLANGE �},µ�,_ 10. EXPOSED PIPING:PROVIDE CHROME PLATING FOR EXPOSED PIPING IN ROOMS,ELECTRICAL ROOMS,AND EQUIPMENT ROOMS NOT SPECIFIED PIPING,AND DUCTWORK PER SMACNA AND LOCAL REGULATIONS. HP HORSEPOWER --� GATE VALVE OR BALL VALVE 5� ( 90°DIVERGING RECTANGULAR TEE, FINISHED ROOMS. TO BE INTERNALLY LINED. HPU HEAT PUMP UNIT EITHER RADIUS OR TURNING VANES B. SUPPLY AIR ABOVE CEILINGS OR EXPOSED NOT SPECIFIED TO BE 5. FILTER CLEARANCE:PROVIDE ADEQUATE CLEARANCE FOR CHANGING AIR HRU HEAT RECOVERY UNIT BALL VALVE 11. PENETRATIONS:PROVIDE ESCUTCHEON PLATES FOR EXPOSED PIPING INTERNALLY LINED. FILTERS. HVAC HEATING,VENTILATING, PRESSURE REDUCING VALVE(PRY) PENETRATIONS AND SHEET METAL FLASHING FOR EXPOSED DUCTWORK C. OUTDOOR AIR INTAKE. AND AIR CONDITIONING PARALLEL FLOW BRANCH PENETRATIONS. 6. DUCTWORK AND PIPING OUTSIDE OF MECHANICAL ROOMS SHALL BE HVU HEATING&VENTILATION i BREAK IN PIPING OR DUCTWORK CONNECTION,EITHER RADIUS OR a a a 4. MISCELLANEOUS DUCT FITTINGS(CONICAL TAKEOFFS,ETC.):WRAP WITH CONCEALED,COORDINATE WITH THE GENERAL CONTRACTOR TO FUR-OUT UNIT RL RAIN LEADER(RL) TURNING VANES o 12. SHAFT AND PLENUM CONNECTIONS:SEAL CONNECTIONS TO AIR SHAFTS INSULATION FOR CONDENSATION CONTROL. AS REQUIRED. HWR HOT WATER RETURN o AIRTIGHT.PROVIDE AIRTIGHT SEAL AROUND PENETRATIONS IN AIR HWS HOT WATER SUPPLY OL OVERFLOW RAIN LEADER(OL) FLEXIBLE DUCT z z y PLAN NOTES 7. FIRE RATINGS:RATED FLOORICEILING JOINT SPACES HAVING DUCTWORK FIX HEAT EXCHANGER O u PLENUMS. INSIDE THEM SHALL BE FIREISMOKE PROTECTED TO MAINTAIN THE 1-HOUR ID INDIRECT DRAIN,INSIDE " CHECK VALVE O ROUND DUCT INDICATOR w T a 13. LIGHT FIXTURE CLEARANCE:COORDINATE LOCATIONS OF MECHANICAL 1. DUCTWORK SHALL BE METALLIC DUCTWORK FLOOR/CEILING RATING PER LOCAL JURISDICTIONS.EXHAUST DUCTWORK DIAMETER o o O a WORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES FOR REMOVAL PENETRATING THE I-HOUR ROOF/CEILING OR FLOORICEILING ASSEMBLY IN INCH AND REPLACEMENT. 2. TEST AND BALANCE WORK SHALL BE PERFORMED BY AN INDEPENDENT SHALL HAVE ACCESSIBLE CEILING FIRE DAMPERS.ALTERNATIVELY,THE KW KILOWATT CONTRACTOR SUBSTITUTIONS & REVISIONS TEST AND BALANCE AGENCY.PROVIDE(3)COPIES OF TEST AND BALANCE EXHAUST DUCTWORK SHALL BE ROUTED INSIDE A RATED SHAFT TO L LONG,LENGTH 14. MOTORS:COMPLY WITH ENERGY CODE ENFORCED BY AHJ FOR MINIMUM REPORT TO OWNER. PROTECT THE CEILING/ROOF RATING PER THE LOCAL JURISDICTIONS. LB POUND EFFICIENCIES UNDER FULL LOAD. MBH THOUSAND BTU PER HOUR 3. COORDINATE DUCTWORK WITH MISCELLANEOUS OBSTRUCTIONS IN 8. FIRESTOP:PIPE,DUCT AND CONDUIT PENETRATIONS THROUGH RATED MECH MECHANICAL 15. ACCESS CLEARANCES FOR MAINTENANCE AND REPLACEMENT:VERIFY CEILING SPACE. ASSEMBLIES SHALL BE FIRE AND SMOKE STOPPED PER CODE. MCA MIN.CIRCUIT AMPACITY CONTRACTOR SUBSTITUTIONS&REVISIONS:PLEASE SUBMIT PROPOSALS FOR SUBSTITUTIONS OR REVISIONS PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS MOCP MAX.OVER CURRENT FOR REVIEW AND APPROVAL PRIOR TO ORDERING MATERIAL OR DOING WORK.FOR EQUIPMENT THAT IS CLEARANCES CAN BE MET.COORDINATE LOCATIONS OF MECHANICAL 4. RESTROOM EXHAUST SHALL BE A MINIMUM OF 10'FROM ANY MECHANICAL 9. DUCTWORK:DUCTWORK SHALL BE SMOOTH SHEET METAL(CLASS-1). PROTECTION SCHEDULED BY MANUFACTURER'S NAME AND CATALOG DESIGNATIONS,THE MANUFACTURER'S PUBLISHED DATA AND/OR SPECIFICATION FOR THAT ITEM ARE CONSIDERED PART OF SPECIFICATION.ENGINEERING COSTS WORK AND WORK OF OTHER TRADES TO PROVIDE ACCESS CLEARANCES OUTSIDE AIR INTAKES. DUCTWORK THROUGH FIRE RATED STRUCTURE AND FLOOR SHALL BE MIN. MTD MOUNTED FOR SERVICE AND MAINTENANCE. 26 GA.STEEL.MAXIMUM LENGTH OF FLEXIBLE DUCTS SHALL BE V-0" OSA OUTDOOR AIR FOR REVISING MEP PLANS SHALL BE ADDRESSED IN THE COST ANALYSIS OF THE SUBSTITUTION 5. ROUTE DUCTWORK UNDERNEATH JOISTS LION. UNLESS OTHERWISE NOTED ON DRAWINGS.DUCTWORK SIZES SHOWN OBD OPPOSED BLADE DAMPER PROPOSAL.CONTRACTOR TO COORDINATE WITH ENGINEER AND DETERMINE ASSOCIATED DESIGN AND PERMITTING COSTS.CONTRACTOR SHALL BE RESPONSIBLE FOR OTHER COSTS ASSOCIATED WITH COORDINATION REQUIREMENTS ARE INSIDE CLEAR DIMENSIONS. OD OUTSIDE DIMENSION OR DIAMETER UNFORESEEN ISSUES RESULTING FROM SUBSTITUTIONS OR REVISIONS. 6. TRANSITION DUCT UNDER BEAMS AND DUCTS.FIELD VERIFY AVAILABLE OPNG OPENING 1. PIPING:COORDINATE WITH STRUCTURAL FOR EXACT LOCATION OF ALL CEILING CAVITY DIMENSIONS. 10. VOLUME DAMPERS:PROVIDE AN ACCESSIBLE MANUAL VOLUME DAMPER P PUMP (y) STRUCTURAL FRAMING AND FOOTINGS AND FINALIZE THE EXACT ROUTING FOR EACH SUPPLY,RETURN,OSA AND EXHAUST OPENING,LOCATED AS PD PRESSURE DROP,PUMPED DRAIN UJ N OF ALL PIPES WITH STRUCTURAL AND AT THE SITE PRIOR AND DURING THE 7. COORDINATE MOUNTING HEIGHT OF DIFFUSERS WITH ARCHITECTURAL FAR UPSTREAM AS POSSIBLE FROM THE OPENING.PROVIDE A MANUAL POC POINT OF CONNECTION H CN CONSTRUCTION. PLANS. VOLUME DAMPER FOR BRANCH MAINS SERVING MORE THAN ONE PRV PRESSURE REDUCING VALVE D01 o OPENING.VOLUME DAMPERS IN NON-ACCESSIBLE CEILING SHALL HAVE A PSIG POUNDS PER SQUARE DRAWINGS ARE DIAGRAMMATIC,SHOWING THE GENERAL LOCATION,TYPE,LAYOUT,AND EQUIPMENT REQUIRED.THE Q Q 2. DUCTWORK:LOCATE AND COORDINATE THE EXACT LOCATION OF SHEET METAL NOTES CONTROL ARM EXTENDED TO AN ACCESSIBLE LOCATION.PROVIDE IN GAUGE o DUCTWORK WITH STRUCTURAL PLANS AND WITH THE GENERAL "YOUNG"REGULATOR OR EQUAL.EXACT LOCATION OF CONTROL DEVICES RA RETURN AIR DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENT.REFER TO ARCHITECTURAL DRAWINGS FOR U m CONTRACTOR PRIOR TO INSTALLATION OF ANY STRUCTURE OR 1. REFERENCE:SMACNA HVAC DUCT CONSTRUCTION STANDARDS,METAL VISIBLE IN FINISHED SPACES SHALL BE COORDINATED WITH THE RD ROOF DRAIN DIMENSIONS.REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND r INSTALLATION REQUIREMENTS.PROVIDE DUCTWORK,CONNECTIONS,ACCESSORIES,OFFSETS,AND MATERIALS m m EQUIPMENT.COORDINATE WITH FRAMING CONTRACTOR TO ASSURE JOIST AND FLEXIBLE,CURRENT EDITION. ARCHITECT. REF REFERENCE NECESSARY FOR A COMPLETE SYSTEM SPACES LINE UP WHEN DUCTWORK MUST PASS THROUGH DIFFERENT RE RELIEF FAN . W O 3 M JOIST SPACES. 2. CLEARANCE:COORDINATE DUCTWORK WITH MISCELLANEOUS 11. CORRIDOR THERMOSTAT:PROVIDE TAMPERPROOF THERMOSTATS IN RG RETURN GRILLE 3 OBSTRUCTIONS IN CEILING SPACE. CORRIDORS.DO NOT PROVIDE PLASTIC GUARDS TO MAKE THE RPM REVOLUTIONS PER MINUTE J ¢ m 3. ADJUSTMENTS:ALL EQUIPMENT,MOTORS,FANS GAS BURNERS,IGNITION THERMOSTATS TAMPERPROOF.PROVIDE BLANK SECURABLE SA SUPPLY AIR •� =o tO DEVICES,DRIVES,ETC.SHALL BE ADJUSTED AND BALANCED TO OPERATE 3. ROUND ELBOWS AND OFFSETS:FULL RADIUS(RID=1.5),5-PIECE THERMOSTAT COVERS. SCH SCHEDULE w O O AT SPECIFIED RATINGS AS REQUIRED FOR THIS PROJECT SITE AND SEGMENTED OR STAMPED.REFER TO SMACNA HVAC FIG 2-7,3-3.DO NOT SF SUPPLY FAN,SQUARE FOOT Q Q 3 z ACCOUNTING FOR ELEVATION ABOVE SEA LEVEL. USE ANGLED OFFSET(TYPE 1).MITERED OFFSET(TYPE 2)MAY BE USED UP SENS SENSIBLE DRAWING INDEX 'z o TO 30 DEGREE OFFSET ANGLE. SG SUPPLY GRILLE lL ° o= VICINITY MAP SMACNASHEET METAL AND AIR U CONDITIONING CONTRACTORS z INCLUDED IN SET NATIONAL ASSOCIATION Z Z SO SCREENED OPENING SP STATIC PRESSURE 0 SS STAINLESS STEEL, O Z SANITARY SEWER CIT O AIr IN T �_ SQ SQUARE B ILDI G DE ART ENT TG TRANSFER GRILLE w N A� V F5 C) "..0 It TYP TYPICAL £� LU (V Fib w UH UNIT HEATER )ATE BY Z UON UNLESS OTHERWISE NOTED w O V VENT 0 a CHA GESA JTHORI KED w VENT VENTILATION,VENTILATOR UNLESSPPROED BY THE G IN PECT R o VTR WAVENTT,WATT,RU I DWG DESCRIPTION Z W WASTE,WATT,WIDE a W WB WET BULB(TEMPERATURE) M0.00 LEGEND,GENERAL NOTES&DRAWING INDEX X M0.01 PROJECT NOTES,TABLES&CALCULATIONS X DATE: 11/15/2023 o�Ec;s'Te M0.02 MECHANICAL SCHEDULES X M2.01 LEVEL I HVAC FLOOR PLAN X SHEET TITLE: s M2.02 LEVELS 24 TYPICAL HVAC FLOOR PLAN X M2.05 HVAC ROOF PLAN X COVER SHEET, GENERAL OTES APPLICABLE CODES M4.00 MECHANICAL DETAILS x DRAWING II �INDEX THESE DRAWINGS ARE BASED ON THE FOLLOWING CODES: PROJECT INFORMATION M8.00 HVAC LOAD CALCULATIONS X PARCEL NUMBERS: Received -2018 WASHINGTON STATE BUILDING CODE 00847300001300(SOUTH WING) SHEET NO. -2018 WASHINGTON STATE MECHANICAL CODE 00847300001200(NORTH WING,OUTSIDE SCOPE OF WORK) NOV 8 0 2023 -2018 WASHINGTON STATE FUEL GAS CODE ro�51� \�\V/�0•00 -2018 WASHINGTON STATE ENERGY CODE 'p`J VENTILATION CALCULATIONS 2018 WSMC-TABLE 403.3.1.1 AREA,SF ACTUAL ZONE AIR OSACFM OSACFM EXH CFM EXH CFM ROOM MECHANICALUNIT(S) ROOM CATEGORY DEFAULT OSACFM OSACFM OSACFM EXH CFM DISTRIBUTION (4) OCCUPANTS DEFAULT PEOPLE PER OSACFM/ OSACFM EXH CFM (WSMC (WSMC (WSMC (WSMC EFFECTIVENESS REQUIRED PROVIDED REQUIRED PROVIDED 0 OCCUPANTS 1,000 SF PERSON /SF /SF PERSON) AREA) TOTAL) TOTAL) o z VI KITCHEN 455 KITCHEN(COOKING) 10 10 20 7.5 0.12 0.7 75 55 130 319 0.8 163 175 399 600 U > r= w DRY STORAGE 52 JANITOR,TRASH,RECYCLING 0 0 0 0 0 1 0 0 0 52 0.8 0 0 65 100 MEN'S RR 52 TOILET ROOM(PUBLIC) 0 0 0 0 0 50 CFM 0 0 0 50 0.8 0 0 63 100 w WOMEN'S RR 52 TOILET ROOM(PUBLIC) 0 0 0 0 0 50 CFM 0 0 0 50 0.8 0 0 63 100 01 DINING ERV-1(900 CFM) 1,160 DINING ROOM 1 43 1 82 70 1 7.5 1 0.18 0 323 209 532 0 0.8 1 665 725 1 0 0 w CORRIDOR A 10/17/2023 TOTAL: 828 900 590 900 1 a 0 OTES: (1)VENTILATION RATES CALCULATED PER TABLE 403.3.1.1 AND ZONE AIR DISTRIBUTION EFFECTIVENESS FROM TABLE 403.3.1.1.1.2 IN THE 2018 WSMC. o z Oppp❑❑❑o0 O D Jq C,,O ❑oO��Ne oFvmvsy�ti:�o 00a O R ms �DO � SS/ONAL�00000 oaaCE3 ,23 11,15 n R0131SON ENGINEERING,INC I-AVEw.Swl E 2 LYNWOOWA930 O36 R0636b3 0 962 R EC�N 0.:9fi2020 NTACT 0 K U U (n a a a 0 0 o w 'w > 3 Y o U � a n w a co LU N IL 000 Q o. o C) REFRIGERANT PIPE INSULATION SCHEDULE(1)(2)(3)(4) 0,5 0 3A. _ a WSEC TABLE C403.10.3 OPERATING a 3 M J C xp to TEMPERATURE INSULATION CONDUCTIVITY NOMINAL PIPE OR TUBE SIZE VAPOR Lu •� ~O 0 N SERVICE RANGE,"F RETARDER NOTES O w 6 CONDUCTIVITY RANGE, MEAN TEMP. 1"TO 1Y2" 4"TO 8"AND REQUIRED Q ^3 z () BTU`IN/HOUR`FT'`"F RATING,°F <1 <1Y2" TO<4" 8" LARGER o z a 2.5" 2.5" NOT USED 201-250 0.27-0.30 150 (5) (5) 2.5" 3.0" 3.0" YES (7)(8) () VRF MAIN HIGH PRESSURE PIPE TO BRANCH CONTROLLER, Z Zz VRF MAIN GAS/SUCTION LINE, 1.5" 1.5" O 2018 WSEC-C DUCT INSULATION SCHEDULE VRF BRANCH SUCTION LINE TO INDOOR UNIT(HOT GAS SUPPLY) 141-200 0.25-0.29 125 (5) (5) 2.0" 2.0" 2.0" YES (7)(8) 2:_ MINI-SPLIT GAS LINE(HOT GAS SUPPLY,HEATING MODE) (� O DUCT TYPE INSULATION TYPE MIN.R-VALUE � ��� Z SUPPLY&RETURN AIR DUCTS IN UNCONDITIONED SPACE MINERAL-WOOL BLANKET 6.0 VRF BRANCH LIQUID LINE TO INDOOR UNIT(LIQUID RETURN), Q M W w rx VRF MAIN LIQUID LINE 105-140 0.21-0.28 100 1.0" 1.0" 1.5" 1.5" 1.5" YES (7)(8) Fil SUPPLY&RETURN AIR DUCTS LOCATED OUTSIDE THE BUILDING MINERAL-WOOL BLANKET 8.0 MINI-SPLIT LIQUID LINE(LIQUID RETURN,HEATING MODE) w SUPPLY&RETURN AIR DUCTS LOCATED IN BUILDING ENVELOPE ASSEMBLY MINERAL-WOOL BLANKET 16.0 O 'Z SUPPLY WITH AIR TEMP<55"F OR>105"F WITHIN CONDITIONED SPACE MINERAL-WOOL BLANKET 3.3 NOT USED 40-60 0.21-0.27 75 0.5" 0.5" 1.0" 1.0" 1.0" YES (7)(8) U SUPPLY WITH AIR TEMP<55"F OR>105"F WITHIN CONDITIONED SPACE DIRECTLY SERVED BY DUCT MINERAL-WOOL BLANKET 0.0 VRF VRF MA I MAIN SUCTION LINE FROM BRANCH CONTROLLER, N GAS/SUCTION LINE, w SUPPLY DUCTS EXPOSED WITHIN CONDITIONED SPACE MINERAL-WOOL BLANKET 0.0 VRF BRANCH SUCTION LINE TO INDOOR UNIT(GAS RETURN) <40 0.20-0.26 75 0.5" 1.0" 1.0" 1.0" 1.5" YES (7)(8) a RETURN&EXHAUST WITHIN CONDITIONED SPACE,DOWNSTREAM OF AN ENERGY RECOVERY MEDIA AND UPSTREAM OF MINERAL-WOOL BLANKET 8.0 MINI-SPLIT GAS LINE(RETURN,COOLING MODE) AUTOMATIC SHUTOFF DAMPER MINI-SPLIT LIQUID LINE(SUPPLY,COOLING MODE) DATE: 11/15/2023 RELIEF&EXHAUST WITHIN CONDITIONED SPACE,DOWNSTREAM OF AUTOMATIC SHUTOFF DAMPER MINERAL-WOOL BLANKET 16.0 NOTES: OUTSIDE AIR INSIDE CONDITIONED SPACE,UPSTREAM OF AUTOMATIC SHUTOFF DAMPER AND GREATER THAN 2,800 CFM MINERAL-WOOL BLANKET 16.0 (1) PROTECT PIPING INSULATION PER WSEC C403.10.3.1 OUTSIDE AIR INSIDE CONDITIONED SPACE,DOWNSTREAM OF AUTOMATIC SHUTOFF DAMPER AND GREATER THAN 2,800 CFM MINERAL-WOOL BLANKET 8.0 (2) INSULATION&COVERING ON PIPE&TUBING SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND SMOKE DEVELOPED INDEX OF NOT MORE THAN 450 PER WSBC 720.7. SHEET TITLE: INSULATION MATERIAL&THICKNESS ARE BASED ON CODE MINIMUM EFFICIENCY ONLY.ADDITIONAL PROVISIONS SHALL BE PROVIDED BY CONTRACTOR AS REQUIRED BY LOCAL AUTHORITIES, PROJECT NOTES, OUTSIDE AIR INSIDE CONDITIONED SPACE AND LESS THAN 2,800 CFM MINERAL-WOOL BLANKET 7.0 (3) MANUFACTURER'S INSTRUCTION,OWNER,BRAND STANDARD AND PROJECT SPECIFICATIONS. TABLES& OUTSIDE AIR DUCT IN UNHEATED EQUIPMENT ROOMS WITH COMBUSTION AIR LOUVERS,ISOLATED FROM CONDITIONED SPACE MINERAL-WOOL BLANKET 0.0 ALTERNATE INSULATION MATERIAL:FOR INSULATION WITH CONDUCTIVITY OUTSIDE THE REQUIRED RANGE SHOWN IN TABLE,THE INSULATION SHALL HAVE A MINIMUM THICKNESS AS CALCULATIONS AT SIDES,TOP AND BOTTOM WITH R-11 INSULATION (4) CALCULATED WITH INSULATION THICKNESS EQUATION AS SHOWN BELOW WSEC TABLE C403.10.3.THIS CALCULATION SHALL BE PROVIDED BY CONTRACTOR AND APPROVED BY AHJ. NOTES: (1) DUCT INSULATION SHALL COMPLY WITH IMC AND WSEC. ENGINEERING CAN PROVIDE CALCULATION OR REVIEW CONTRACTORS CALCULATION UNDER SEPARATE CONTRACT OR ADD SERVICE. (2) VAPOR RETARDER IS INSTALLED ON SUPPLY AND OUTSIDE AIR DUCT PER IMC 604.11. (5) REDUCE INSULATION THICKNESS BY 1-INCH TO A MINIMUM INSULATION THICKNESS OF 1-INCH IF PIPE IS IN PARTITIONS WITHIN CONDITION SPACE PER WSEC TABLE C403.10.3 (3) EXTERNAL DUCT INSULATION IS IDENTIFIABLE PER IMC 604.7. (6) OPERATING TEMPERATURE:TYPICAL OPERATING TEMPERATURE RANGE OF EACH SYSTEMS IS SHOWN ON THIS TABLE.CONTRACTOR SHALL VERIFY THE ACTUAL OPERATING TEMPERATURE (4) ALL DUCTWORK IS CONSTRUCTED AND SEALED PER IMC. OF PIPE.IF ACTUAL OPERATION TEMPERATURE OF PIPE IS OUTSIDE TEMPERATURE RANGE,CONTRACTOR SHALL SUBMIT RFI TO ENGINEERING. SHEET NO. (5) INSULATION SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND A MAXIMUM SMOKE DEVELOPED INDEX OF 50 PER IMC 604.3. (7) INSULATION MATERIAL SHALL BE CLOSED-CELL ELASTOMERIC. O•O (8) ALL PIPES SHALL BE INSULATED INDEPENDENT OF ONE ANOTHER. SPLIT HEAT PUMP SCHEDULE -OUTDOOR UNIT COOLING HEATING ELECTRICAL EQUIP NO. SERVICE NOMINCAL SEER/EER HSPF/COP ,SOUND WEIGHT LBS BASIS OF DESIGN(1)(2)(3)(4)(5)(6)(7) CONNECTED CAPACITY,TONS CAPACITY,BTU/H CAPACITY,BTU/H 041F VOLTAGE MCA MOCP PRESSURE,dBA INDOOR UNITS RATED REQUIRED RATED REQUIRED HP-1 DINING 4.0 48,000 16.5/11.3 14.0/- 54,000 11.013.3 8.2/-- 208V/1P 29 44 54 271 MITSUBISHI PUMY-P48NKMU3 FCU-1 cn HP-2 KITCHEN 2.0 24,000 24.7/14.3 14.0/- 29,000 9.3/4.35 8.2/-- 208V/1P 19.0 26 48 165 MITSUBISHI PUZ-A24NHA7 FCU-2 O NOTES: (1) ARI LISTED WITH ALL STANDARD FEATURES,INSTALLATION ACCESSORIES AND COMPRESSOR SHORT CYCLING PROTECTION.FILTER DRIVER,REFRIGERANT LINE FILTER,LIQUID SOLENOID VALVE,AND SAFETY PRESSURE SWITCHES.INSTALL REFRIGERANT TUBING AND LENGTH IN STRICT _0 5 ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION. �" w (2) PROVIDE FACTORY OPTION ELECTRICAL DISCONNECT. (3) ROUTING OF REFRIGERANT LINES FROM INDOOR TO OUTDOOR UNITS NOT SHOWN ON PLANS.CONTRACTOR TO FIELD COORDINATE ROUTING. v (4) ROUTE CONDENSATE TO APPROVED DRAIN. N (5) PROVIDE ALL REQUIRED ACCESSORIES FOR LOW-AMBIENT AND LONG-LINE APPLICATIONS. (6) REFRIGERANT SHALL BE R-410A.FAN SHALL HAVE EC MOTOR. (7) ECONOMIZER NOT REQUIRED PER EXCEPTION 1 C403.5(DOAS).COMMERCIAL SPACE IS VENTILATED BY ERVS. (8) HEAT PUMPS ARE SIZED PER HVAC LOAD CALCULATIONS ON SHEET M8.00. o o z °p❑Oo O oo00 O ❑o0°°�Ne oFvvvsy�ti2°°a SPLIT HEAT PUMP SCHEDULE - INDOOR UNIT DO�osla °aa000° 5,23 FAN ELECTRICAL DIMENSIONS,INCHES SOUND CONDENSATE DRAIN 1 �� MOUNTING/ COOLING HEATING CONNECTED EQUIP NO. SERVICE DISCHARGE MAX AIRFLOW,CFM ESP,WG IN CAPACITY(BTU/H) CAPACITY(BTU/H) VOLTAGE MCA MOCP L �/y H dBA (INCHES)PRESSURE, OUTLET DIAMETER BASIS OF DESIGN(1)(2)(4) OUTDOOR UNIT FCU-1 DINING CEILING DUCTED 1300 0.6 48,000 54,000 208V/1P 4.38 15 29 60 9 44 1-1/4" MITSUBISHI PEFY-P48NMAU-E4 HP-1 FCU-2 KITCHEN CEILING CASSETTE 810 - 24,000 29,000 (3) (3) (3) 38 38 12 36 1-1/4" MITSUBISHI PLA-A24LA(3) HP-2 NOTES: (1) PROVIDE ELECTRICAL DISCONNECT SWITCH AND INDIVIDUAL THERMOSTAT FOR EACH UNIT. (2) PROVIDE INTEGRAL CONDENSATE PUMP KIT AND ROUTE CONDENSATE TO APPROVED DRAIN. ROBISON (3) INDOOR UNIT IS POWERED FROM OUTDOOR UNIT. ENGINEERING,INC (4) THERMOSTAT TO BE INITIALLY SET TO 68°F(ADJUSTABLE). a61aorHnvew,swr LY00,313—66 RNW00636b3E3m REIPFOJEC�N0.:9fi2020 K K K U U (n a a a 0 0 o w z > 3 � Y o U � a in w a w = a O � U Q co W N LL Doo Q O` o U � 05 ° W a J a3� ENERGY RECOVERY VENTILATORS uj Q o3N Q w Z Z FAN ELECTRICAL rn i Oz SENSIBLE INCHES WEIGHT BASIS OF DESIGN d a EQUIP NO. SERVICE FILTER EFFECTIVENESS AIRFLOW, SUPPLY EXHAUST AMPS/ (LBS) (1)(2) _ (� ESP.IN WG / VOLTAGE MOCP L W H CFM FAN HP FAN HP MCA 7 U DIFFUSER SCHEDULE KITCHEN,DINING,STORAGE, O S= Z ERV-1-1 RESTROOMS 900 0.5 MERV-8 74.2% 208V/1P 0.5 0.5 -111.10 15 31 47 18 225 RUSKIN MV 75OXE CALLOUT DESCRIPTION AIRFLOW RANGE, FACE SIZE ENERGY RECOVERY SYSTEM SHALL HAVE THE CAPABILITY TO PROVIDE A CHANGE IN THE ENTHALPY OF THE THE OUTDOOR AIR SUPPLY OF NOT LESS THAN 50 PERCENT OF THE DIFFERENCE BETWEEN THE OUTDOOR AIR AND RETURN 2:_ O (, CFM ,IN BASIS OF DESIGN(1) NOTES: (1) AIR ENTHALPIES,AT DESIGN CONDITIONS. (n O U) Z CD-2 CEILING SUPPLY DIFFUSER 0-350 12x12 TITUS TDC (2) PROVIDE OCCUPANCY SENSORS PER WSEC C403.7.2 TO SWITCH UNIT BETWEEN OCCUPIED AND UNOCCUPIED MODE. L0 RG-7 SIDEWALL RETURN GRILLE 0-850 14x14 TITUS 350ZRL 0 W RG-8 SIDEWALL RETURN GRILLE 0-1700 18x18 TITUS 350ZRL W EG-2 CEILING EXHAUST GRILLE 0-615 12x12 TITUS 350ZRL O Z EG-3 CEILING EXHAUST GRILLE 0-1200 18x18 TITUS 350ZRL F SG-3 SIDEWALL SUPPLY GRILLE 0-350 12x8 TITUS 30ORL v NOTES: (1) ALL DIFFUSERS,REGISTERS,AND GRILLES SHALL BE FACTORY PAINTED. p W a DATE: 11/15/2023 SHEET TITLE: MECHANICAL SCHEDULES SHEET NO M0.02 0(6.7 7 (7.5 8 I I N z 0 I ZN O j DEMO ADDED a WALLS WALL a w 0 II II oc a MERCH REFER ME o SHELVING DISPLAY CASE SHELVING ORDER II (FUTURE) II CONDIMENTS/ TRASH O Z WALL DINING 1300 RE`Eu eEL I F °°oDDDoo 0 FCUMF 1 �ac�°O°o ROOM 00 4 ow\ 000� oF�N;ti?oo (35)SEATS 1,300 o MAX OCC.=49 2C0 TONS o°o ss/QVAL aK� 1,200 CFM °poao1 4-TOP 4-TOP(42"D) (42"D) T T CD-2 KITCHEN ROBISON 175 ENGINEERING,INC 375 375 6Tre AVEw.S111 c2 CD-3 �YNNJl000,WA93036 PREP/ 0636b33E3m 725 1 4� 1 8� reEiPNaccrrvo sfizozo "� COOK S -4 -4 D D PICK-UP o 0 a a a I4-TOP I � 4-TOP 4-TOP -- - 4 42 D 42 D _ I 4 U U , in w a w = a I ES 80 600 ` soli ERV-1-1 � �� ❑ SCULLERY ,' 900 CFM \ I I NGE �- CONDIMENTS/ comws. � TRASH L � �\+ 71 co wN X z-roP 140 140 80 ILL ap ol 2-TOP rac < Q o E —1 E 1 EG 1 U w J N'S WOMEN'S 1 o 1 DRYao 0,5 E 'm-0 o WQa RCH TO (ARCH TO STORAGE > V RIFY) VERIFY) J a 3 LF OF w s =o0 L O O N Q ��z Zo Ella DINING LL: _ � (� / COUNTER 7 •Q Z O ADDED V G 0 _ WALL O (J) Z I�..I C o0 mw a W LEVELI H V A C PLAN . - * DATE 5,2023 SCALE: 1/4" — 1'-0' ` SHEET TITLE: 5 7 ❑ I SHEET N0. M2.01 Z O Z N O j F- W w 0 w i_ 0 HP-1 0 DINING Z �-`- -- z,� 4.0 TONS 271 LBS o°°oAc�Ooo o° E.. s o O _____ 000�';e�oFvuvSyiti�?O°p0 O o O° ss/QVAL EtF'�oO00 H P—2 °paa000°°5 23 KITCHEN �� 1 2.0 TONS 165 LBS � ' r: ROBISON ENGINEERING,INC i aorH AVEw,swrc3c Nw000,WA93036 LY R0636b3 0 9 RN]"RC�N ROCK. AD 020 K K K U U (n a a a 0 0 o w 'w 3 o z Y U � a in w a w T a O � U Q O O M w N LL 0No Qa o o U � 06 ° W a J a3� ED Q ogN Q W Z Z Oa d °z � U Z Zz 0 - 0 U) z Lo C) 0 m-, W w o m w U ROOF H VAC PLAN a W DATE: 11/15/7 SCALE: 1/4" — 1'-0" SHEET TITLE: SHEET NO M2.02 FUNCTIONAL DEVICES TERMINALS ON DELAY RELAY HVAC UNIT #RIBD0IBDC OR EQUAL THAT 5-MINUTE DELAY ENABLE/DISABLE (MC) HATING& COOLING 120V POWER BLU _____________ 120VAC PER � N N/C POWER PLAN _ YEL C DISCONNECT N SWITCH N pG LOW VOLTAGE HVAC UNIT O (EC) WIRING (MC) z 'n 0 > (MC) LOW VOLTAGE a it DOOR CONTACTS DRY CONTACT INPUT v TO CLOSE WHEN N DOOR OPENS I o (MC) r — SEQUENCE OF OPERATION LOW VOLTAGE CONTROL 1. PROVIDE CONTROLS TO DISABLE HATING&COOLING ON HVAC o INPUT WIRING UNIT WHEN OUTSIDE DOOR REMAINS OPEN 5 MINUTES OR (MC) LONGER,PER WSEC C403.4.1.6. 2. WHEN ENTRY DOOR IS OPENED,THE DOOR SWITCH CONTACT o CLOSES AND SIGNALS DELAY RELAY TO START DELAY z PROVIDE KADTRONIX HVAC SEQUENCE. HEN ESMART QUIVALENT SYSTEM OR 3 H AS OWNER PROPS DOOR OPEN ON A NICE DAY),THE HEATING NT & OO�po AC�000 COOLING ON THE HVAC UNIT IS DISABLED. <v; oFv�wsy� 4. THE FAN CAN STILL OPERATE TO CIRCULATE AIR. p'p00 OO tie ti ? a 5. WHEN THE DOOR CLOSES,THE CONTROLS ENABLE HEATING& ❑ COOLING. ❑ NOT USED HEATING/COOLING DISABLE WITH DOOR SWITCH 6 HTHE EATING OSEOOLING F THESE CONHENTROLS IS TO IS PREVENT LEFT WASTING �p0^F99/ONAL EtF'�oOO DETAIL 6 DETAIL MAIN ENTRY DOOR 1 p�p❑❑0015 �3 (NOT TO SCALE) 11' SCALE:NONE M4.00 SCALE:NONE M4.00 �w ROBISON ENGINEERING,INC '—EW.SUITE— NW000WA93036 LY R0636b33E3m RNIT'--N0.:9fi2020 K � K U U (n a a a 0 0 o w z > 3 � Y o U � a in w a NOT USED NOT USED NOT USED `o w N DETAIL DETAIL 4 DETAIL z < 00 Q °l N SCALE:NONE M4.00 SCALE:NONE M4.00 SCALE:NONE Wo wed � a J a 3 M C xp to w Q ogN Q Z w Z O d °'tea V U Z Zz O cn o U) z 0 wL mW w LaU W DATE: 11/15/2023 SHEET TITLE: MECHANICAL DETAILS NOT USED NOT USED NOT USED DETAIL DETAIL DETAIL SHEET NO. SCALE:NONE M4.00 SCALE:NONE M4.00 SCALE:NONE /M4.00 M4.00 Z ) Z Vl O j F- W 0 0 0 z °popoopo° o°O°°�Ne oFWasy/ti��°Oa 11/1523,1:08 PM den hvaotoatlsl.hMl 11/1523,198 PM den hvaoloatlsl.hMl 11/15/23,198 PM cm_hvac-loadst html O Load Total Summary-System Room Information,Part 2 (tacludes Ventilation and Plenum Loads) Felues in i(dics have been changedfromthe d�uh Project Information °°o Si ,L pO°o Conlin Hearin Pmjeet Name: �l7ED° (Ji23 g 8 Equipment Load People Glass Lontion Area bmh Tons Number Lighting Load Pmjeet Location: Arlington,WA D2/ CFM/ CFM/ CFM/ Sensible Latent Sensible bmh/Person Latent bmh/Persov Zone Type - CFM Peak CFM bmh kW Heating Safety Factor(Roam): 0% Total Sensible Latent Total Sensible Lalenl ma ton it2 BZ D]NIG ROOM 0.8 watts/fl 7,160 0 0 43 people 275 275 B Default Heating Temperamre: 68°F 1,610 Heatvg Safety Factor(Vevtilatiov): 0% Zone Default OS 1,450 July 12'' 60,800 36,600 24,200 5.1 3.1 2 318 285 0.9 1,450 20,600 6.1 0.9 KITCHIN 0.8 watts/0 1,240 11.5 watts/fl2 776 0 to people 375 625 B Coaling Safety Factor(Ruom): 0% Tempered OSA tl2 P.m. Dafadt Cooling Temperamre: - F Cooling Safety Factor(Ventilation): 0% Room DINING L160 5:00 ROOM a 1,170 July P m 46,400 29,700 16,700 3-9 2.5 .4 300 304 1.01 725 17,300 5.1 0.63 Default Relative Humidity: 50°° Floor Slab Heal Lms Coeificiem: 0.54 3:00 Ventilation Schedule Calculation Date: November 15,2023,1:08 pm. Room KITCHEN 455 ft 2711Wy p m 14,4fq 6,900 7,470 1.2 0.6k..6 3R0 226 0.6 175 3,310 1 0.39 Design Conditions D O B I O N Ventilation Area Ventilation Supply Ventilation R Location Room-type Requirements (R2) People CFM CFM % OSA Low: 18°1 Latitude: 48°N Zane Default- OSA Daily Range: 16°1 Elevation: g2' ENGINEERING,INC 1,610 53 900 1,450 62 not notry nvrw,surtssc� Load Total Summary-Room Tempered OSA OSA High Dry Bulb OSA High Wet Bulb rvrvw000 wnasosc Room DNIG (SMC/WSMC 2018)Dmmg Room- July 86°F 68°F 2o69aa-- (Excludes Ventilation and Plenum Loads) ROOM (Food Service) Direct 1,160 43 725 1,170 62% reNiCON PRWTPC o..9a2a2o AD Cooling Healing Locatioe Area bluh Tons (SMC/WSMC 2018)Ki[chea Cookmg- CFM Peak ft2/ CFM/ CFM/CFM bmh kW CFM/ Room KITCHEN (Feed F�Service) Direct 455 10 175 Tom]Sensible Lalenl MW Sensible Latent ton toe fl2 D2 Wall Types Zone Default- 1,610 1 450 CV-Sum of 50200 31,700 18,400 4.2 2.6 I.5 386 346 0.9 900 8,040 2.4 0.56 Wan Type D-Yams ASHRAE Type Color Descrill Tempered OSA R2 Peaks Edisoa's Cafe Wall 0.078 1 Dark Mass Wall(2015 WA Mmimum) K K Room DB4I]G 1,160 5�00 Cooling Load Details-System ROOM tt21,170 July Pm. 37,800 25,80012,100 3.2 22 1 367 372 1.01 7257,180 2.1 0.63 (Btdh/%Total) a a a 3:00 (See"Cooling Load Derails-Room-for lighting,equipment,and people loads) Walls Room KITCHEN 455 ftz 271 July I2,300 5,960 6,350 1 OS 0.5 443 264 0.6 175 861 0.3 0.39 W P.m. Ventilation InDNration Room Number Length Height Area(Minus Doors and Glass) Type Facing Direction On Perimeler Z Z y O Location Peak Roof W.I. Class Sensible Latent Sensible Latent 3 O U DINING ROOM 31'-8" 10' 215 R Edison's Cafe Wall W Zone Default-T pemd OSA July 12.00 p.m. 0 0% 1,920 3% 8,470 14% 4,151 8% 5,760 9% 584 1% 352 1% K w S d Room DINING ROOM July 5:00 p.m. 0 0% 1,920 4% 8,470 IS% 3,900 8% 4'640 10% 395 1% 249 1% DINING ROOM 3'-9" 10 38 R2 Edison's Cafe Wall W O U Q Room KITCHEN July 3011p.m. 0 0% 0 0% 0 0% 942 7% 1,120 8% 190 1% 102 1% DINING ROOM IS' l0' 150 R2 Edison Cafe WA S Cooling Load Details-Room Glass Types (B./h/%of Total) On.Type D-Value I SHGC I Deacripthm Location Peak Roo Wall I Glaas I Lighting Equipment People Infiltration Edisw's Cafe Glazed Door 0.6 0A 2015 WA Min Window(Entrance Door) Sensible Latent Sensible Latent Sensible Latest EdiaoWs Cafe Window 0.38 0.4 2015 WA Min Window(Metal Framed,Fired) Zone Default-T pered Cv-Sum of Pek OSA Pes 00%1,9204%8,47017%4,400 9%7762%0 0%15,60031%18,10036%5841%3521% ak Glass Room DINING ROOM July 5:00 pm. 0 0°/1920 5%8,470 22%3,160 B% 0 0%0 0%11,800 31%11,800 31%395 1%249 1 Room KITCHEN July 3:00p.m. 00% 01-1 0(11,240 10%776 6%0 0%3,75030%6,25051%1%2%1021% Raom Number Area Type Facing Direction Shaded DINING ROOM 21 ft Fdisou's Cale Glazed Door W DINING ROOM 80 1112 Ediaon's Cafe Window W CY) W N Heating Load Details-System and Room L L 04 (Btu/b/%of Sysmm Total) 01 Location Roof Wall Glass Slab Ventilation Infiltration,Infiltration, Room Information,Part 1 Q Q N Zone Default-T OSA 0 0% 1,570 8% 2,150 10% 1,360 7% 12,600 61% 2,960 14% 0 a� Fdues in italics have been changedfmm the def uh cn tu Room DI4ING ROOM 0 0% 1,570 9% 2,150 12% 1,360 8% 10,100 59% 2,100 12 Ceiling Ventilation Infiltration Cooling Heating Relative Room KITCHEN 0 0% 0 0% 0 0% 0 0% 2,450 74% 861 26% Number Name Area W M Height C--; Heating CooHag Hcatiag Temperamre Temperamre Humidity _�( (SMC/WSMC 2011) 0.25 {J(� _O �00 M DINING 1,160 125 Same as 725 39 Setae as 39 Dining Room- 8'Direct AC/ 75°F 68°F 50•/ ROOM (F�Service) t12 CFM cooling CFM hom CFM cooling CFM J Q (SMC/WSMC 2018) 0.25 •� H O p 455 175 Same as 175 16 Same as 16 O KITCHEN Kitchen Cooking- I'Di- AC/ 75°F 68°F 50•A O (Food Service) 11? CFM cooling CFM hour CFM cooling CFM Q Q 3 tit Z Z O fileJW:/962 Gmadsiew NoM LLU962-028 Edisoes Cafe Mington,WA/Dwg/dm_hvaaloadsl.html 3/3 file:///F:1%2 GmMview North LLC/%2-028 Edisous Cale Atlington,WAM-91dm_hvaaloads1.henl 2/3 file:i//F:1%2 GMMWew NoM LLC/%2-028 Edi.o s Cafe Mington,WA/Dwgfdm_hvaaloadsl.hbnl 1/3 �/) U Z Zz 0 60 o (j) z �, w0 mW w U a W DATE: 11/15/2023 SHEET TITLE: HVAC LOAD CALCULATIONS SHEET NO M8.00 GENERAL NOTES SYMBOLS ABBREVIATIONS 1. REFERENCE TO RELATED WORK:"REF'INDICATIONS DENOTE WORK COVERED ELSEWHERE(ARCHITECTURAL, GENERAL PIPE SYMBOLS ABV ABOVE FPM FEET PER MINUTE OPD OVER PRESSURE DEVICE STRUCTURAL,CIVIL,ELECTRICAL,LANDSCAPE,OR KITCHEN),OR ITEM BASED ON A SPECIFIC MANUFACTURER'S AD AREA DRAIN FPS FEET PER SECOND OPNG OPENING DIMENSIONS(VERIFY). --- ARCHITECTURAL BACKGROUND Cl TOP PIPE CONNECTION AFF ABOVE FINISHED FLOOR FS FLOOR SINK P PUMP AHJ AUTHORITY(THIN LINE) HAVING JURISDICTION FT FEET PD PRESSURE DROP,PLANTER DRAIN 2. ELECTRICAL CHARACTERISTICS:REFER SS ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS(VOLTAGES, BFF BELOW FINISHED FLOOR FU FIXTURE UNITS POC POINT OF CONNECTION BOTTOM PIPE CONNECTION BFP BACKFLOW PREVENTER G GAS(LOW PRESSURE) PRV PRESSURE REDUCING VALVE ETC.OF MECHANICAL EQUIPMENT,UNLESS OTHERWISE INDICATED. NEW PIPING(HEAVY LINE) BOH BACK OF HOUSE GAL GALLONS PRESSURE RELIEF VALVE 3. CODES:COMPLETE INSTALLATION OF THE PLUMBING SYSTEM SHALL BE PER THE APPLICABLE BUILDING, PIPE TURNING UP BP BOOSTER PUMP GO GARAGE DRAIN PS PUMPED STORM DRAINAGE MECHANICAL,ENERGY,PLUMBING,FIRE,AND HEALTH CODES AND REGULATIONS AS ADOPTED BY HE LOCAL AHJ. EXISTING PIPING(THIN LINE) J PIPE TURNING DOWNIDROP BT BATHTUB GM GAS METER PSIG POUNDS PER SQUARE INCH GAUGE BTUH BRITISH THERMAL UNIT PER HOUR GPG GRAINS PER GALLON PSD PUMPED STORM DRAINAGE 4. PREPARE AND SUBMIT FOR REVIEW A SHOP DRAWING BASED ON FINAL STRUCTURAL SHOP DRAWINGS FOR ] PIPE CAP C COMMON GPM GALLONS PER MINUTE PSS PUMPED SANITARY SEWER LOCATING AND ROUTING ALL EQUIPMENT,PIPING,ETC. EXISTING WORK TO BE REMOVED CAP CAPACITY GV GATE VALVE PSW PUMPED SANITARY WASTE A. COORDINATE FLOOR AND BEAM PENETRATIONS WITH STRUCTURAL. I PIPE PLUG CB CATCH BASIN GWB GYPSUM WALLBOARD PW PUMPED WASTE B. COORDINATE FINAL LOCATION AND ROUTING WITH CEILING,LIGHTS,WALLS,FIRE SPRINKLER PIPING,AND CD CONDENSATE DRAIN GWH GAS WATER HEATER RD ROOF DRAIN OTHER TRADES WORK MATCHL UNION INE OR PROPERTY LINE CFF CAPPED FOR FUTURE HB HOSE BIBB REF REFERENCE C. INCLUDE ADDITIONAL OFFSETS,ELBOWS,ROUTING,EQUIVALENT DUCT SIZING EXCHANGE,RELOCATING,ETC. CFM CUBIC FEET PER MINUTE HD HEAD RPBP REDUCED PRESSURE BACKFLOW i CI AS REQUIRED FOR A COMPLETE OPERATING MECHANICAL SYSTEM. CONNECTION TO EXISTING 1 FLANGE CLG CAST IRON HDR HUB DRAIN PREVENTER D. PROVIDE SHOP DRAWINGS AT NO ADDITIONAL COST TO THE OWNER. CEILING,COOLING HEDV HOSE END DRAIN VALVE RPM REVOLUTIONS PER MINUTE WYE STRAINER CLW CLOTHES WASHER HORIZ HORIZONTAL S SINK 5. PLUMBING CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF ALL PLUMBING EQUIPMENT WITHIN SECTION IDENTIFICATION CO CLEANOUTS HP HORSEPOWER SCH SCHEDULE THE STRUCTURE. WYE STRAINER WITH CAPPED HOSE COMB COMBUSTION HPCW HIGH PRESSURE COLD WATER SCW SOFTENED COLD WATER END SLOWDOWN VALVE CONT CONTINUE,CONTROL HW HOT WATER SO STORM DRAIN 6. ACCESS DOORS:COORDINATE WITH ARCHITECT AND LOCATE ALL ACCESS DOORS ON SHOP DRAWINGS PRIOR TO INDICATES DIRECTION OF CUTTING CONTR CONTRACTOR HWC HOT WATER RE-CIRCULATION SEP SEWAGE EJECTOR PUMP BEGINNING OF CONSTRUCTION,ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE FIRE RATED.VERIFY ACCESS PLANE � BALL VALVE COTG CLEANOUTS TO GRADE HWCP HOT WATER CIRCULATION PUMP SF SQUARE FOOT DOOR LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO BIDDING. CP CIRCULATING PUMP HWR HOT WATER RETURN SGSV SEISMIC GAS SHUTOFF VALVE LETTER INDICATES SECTION BALL VALVE rwt CV CHECK VALVE HWST HOT WATER STORAGE TANK SH SHOWER �+.1- 7. ROOF PENETRATIONS:SEE ARCHITECTURAL DRAWINGS FOR ROOF CAP,ROOF CURB,ROOF DRAIN,OVERFLOW NO.INDICATES DETAIL CW COLD WATER HX HEAT EXCHANGER SO STORM OVERFLOW ( ) -Dill D DIAMETER ICW INDUSTRIAL COLD WATER SP STATIC PRESSURE/SUMP PUMP F-� JACkS DRAINS AND VTR DETAILS. A GLOBE VALVE I.�.� 4r:'Fy+lg4`'O DB DRY BULB,DECIBEL ID INDIRECT DRAIN,INSIDE DIAMETER SR SUDS RELIEF p �:"F,p "u�.'•.y 8. EXPOSED PIPING:PROVIDE CHROME PLATING FOR EXPOSED PIPING IN FINISHED ROOMS. P-3 P-3 SHEET NUMBER WHERE SECTION IS �\ OF DRINKING FOUNTAIN IE INVERT ELEVATION SS STAINLESS STEEL/SANITARY SEWER CHECKVALVE DRAWNDFU DRAIN FIXTURE UNITS IHW INDUSTRIAL HOW WATER SSS SIDE SANITARY SEWER 9. PENETRATIONS:PROVIDE ESCUTCHEON PLATES FOR EXPOSED PIPING PENETRATIONS AND SHEET METAL FLASHING SHEET NUMBER WHERE SECTION IS DI DUCTILE IRON IN INCH STD STANDARD mow- BALANCING OR PLUG VALVE DIM DIMENSION KS KITCHEN SINK SO SQUARE �O R �:'• FOR EXPOSED DUCTWORK PENETRATIONS. TAKEN \� BUTTERFLY VALVE ON DOWN KW KILOWATT TO TRENCH DRAIN 10. SHAFT AND PLENUM CONNECTIONS:SEAL CONNECTIONS TO AIR SHAFTS AIRTIGHT.PROVIDE AIRTIGHT SEAL DS DOWN SPOUT L LONG,LENGTH TMV THERMOSTATIC MIXING VALVE AROUND PENETRATIONS IN AIR PLENUMS. DWG DRAWING LAV LAVATORY TP TRAP PRIMER p 5� DETAIL IDENTIFICATION �,/�/W'I (E) EXISTING LB POUND TYP TYPICAL 11. LIGHT FIXTURE CLEARANCE:COORDINATE LOCATIONS OF MECHANICAL WORK TO PROVIDE CLEARANCES OVER FLEXIBLE CONNECTION IN PIPING EFF EFFICIENCY M WATER METER UH UNIT HEATER DETAIL NUMBER � ELEC ELECTRIC MBH THOUSAND BTU PER HOUR LON UNLESS OTHERWISE NOTED L I GHT ING FIXTURES FOR REMOVAL AND REPLACEMENT. � DRAWING/SHEET NUMBER EQUIV EQUIVALENT MECH MECHANICAL UR URINAL 12. CABLE TRAYS:PIPING INSTALLED ADJACENT TO ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM ACCESS OF 6" - PRESSURE REDUCING VALVE(PRV) EWC ELECTRIC WATER COOLER MCA MIN.CIRCUIT AMPACITY V VENT ABOVE AND TO THE SIDE OF CABLE TRAYS. PRV EWH ELECTRIC WATER HEATER MOCP MAX.OVER CURRENT PROTECTION VTR VENT THRU ROOF pp EXT EXTERIOR,EXTERNAL MPG MEDIUM PRESSURE GAS W WASTE,WATT,WIDE 13. MOTORS:COMPLY WITH ENERGY CODE ENFORCED BY AHJ FOR MINIMUM EFFICIENCIES UNDER FULL LOAD. nln AUTOMATIC CONTROL VALVE,2-WAY F FAHRENHEIT MTD MOUNTED WC WATER CLOSET EQUIPMENT �/•� FCO FLOOR CLEANOUTS (N) NEW WCO WALL CLEANOUTS 14. ACCESS CLEARANCES FOR MAINTENANCE AND REPLACEMENT:VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO FD FLOOR DRAIN NC NORMALLY CLOSED WHO WALL HYDRANT O BI SO N ENSURE THAT ACCESS CLEARANCES CAN BE MET.COORDINATE LOCATIONS OF MECHANICAL WORK AND WORK OF TYPICAL EQUIPMENT DESIGNATION AUTOMATIC CONTROL VALVE - --- ,3-WAY F OTHER TRADES TO PROVIDE ACCESS CLEARANCES FOR SERVICE AND MAINTENANCE. FF FIRE FINISHED T CONNECTION NO NORMALLY OPEN WM WASHING MACHINE ENGINEERING,INC FLOOR OD OUTSIDE DIMENSION/DIAMETER WSFU WATER SUPPLY FIXTURE UNITS 19401dm""�'"-51AiE3p2 HWCP-1 FLR FLOOR OVERFLOW DRAIN/DECK DRAIN ass RELIEF VALVE rmawecrrvo:sszo� COORDINATION REQUIREMENTS ID conr"cr:aErwaocxs�nn 1. IRRIGATION SYSTEM:COORDINATE IRRIGATION WATER DEMAND,MINIMUM WATER PRESSURE REQUIREMENTS& CONTRACTOR SUBSTITUTIONS & REVISIONS CONTROL CABINET LOCATIONS WITH IRRIGATION CONTRACTOR. PIPING K Ij�j� BALANCING/MEASURING VALVE 0 2. GAS:CONTRACTOR/GAS COMPANY SHALL FINALIZE GAS METER AND GAS SERVICE LOCATIONS.INSTALL SEISMIC -W- WASTE BELOW GRADE REDUCER PLEASE SUBMIT PROPOSALS FOR SUBSTITUTIONS OR REVISIONS FOR REVIEW AND APPROVAL PRIOR TO ORDERING MATERIAL OR DOING GAS SHUT OFF VALVE PER GAS COMPANY REGULATIONS. W WASTE ABOVE GRADE ► DIRECTION OF FLOW WORK.FOR EQUIPMENT THAT IS SCHEDULED BY MANUFACTURER'S NAME AND CATALOG DESIGNATIONS,THE MANUFACTURER'S PUBLISHED MEP 3. UTILITIES:COORDINATE WITH SITE UTILITY CONTRACTOR AND CIVIL DRAWINGS FOR UTILITY CONNECTIONS AND pW PUMPED WASTE A DATA SHALLI BEOADDR SISED IN HEOCOST ANALYSIS OF THE SUBSTITUTION PROPOSAL.CONTRACTOR TO COORDINATE WIT H THAT ITEM ARE CONSIDERED PART OF SPECIFICATION.ENGINEERING COSTS FOR RIENGINEER D PLANS EXTENSIONS. �� PIPE ANCHOR IW INDIRECT WASTE DETERMINE ASSOCIATED DESIGN AND PERMITTING COSTS.CONTRACTOR SHALL BE RESPONSIBLE FOR OTHER COSTS ASSOCIATED WITH 4. ROOF DRAINAGE:COORDINATE WITH GENERAL CONTRACTOR FOR ROOF DRAIN AND OVERFLOWS,SCUPPER DRAINS, SS SANITARY SEWER ABOVE GRADE - PIPE ALIGNMENT GUIDE UNFORESEEN ISSUES RESULTING FROM SUBSTITUTIONS OR REVISIONS. AND CONDENSATE DRAINS. 1 I 5. PLUMBING FIXTURES&EQUIPMENT:COORDINATE EXACT LOCATION OF ALL PLUMBING FIXTURES&EQUIPMENT WITH -SS- - SANITARY SEWER BELOW GRADE I PS PIPE SUPPORT NOTE TO CONTRACTOR ARCHITECTURAL AND OTHER TRADES DOCUMENTS. -V- VENT pOC VALVE STATION OR ASSEMBLY - 6. PIPING:COORDINATE EXACT LOCATION OF ALL STRUCTURAL FRAMING&FOOTINGS AND FINALIZE THE EXACT RL RAIN LEADER ROUTING OF ALL PIPES WITH STRUCTURAL ENGINEER AT THE SITE PRIOR TO AND DURING THE CONSTRUCTION. ORL OVERFLOW RAIN LEADER 1 ID INDIRECT DRAIN,PIPE TO DRAIN DRAWINGS ARE DIAGRAMMATIC,SHOWING THE GENERAL LOCATION,TYPE,LAYOUT,AND EQUIPMENT REQUIRED.THE COORDINATE UNDER GRADE PIPING&FOUNDATION DRAINAGE PIPING WITH CIVIL ENGINEER. DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENT.REFER TO ARCHITECTURAL DRAWINGS FOR CD CONDENSATE DRAIN DIMENSIONS.REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND 7. ADJUSTMENTS:ALL EQUIPMENT,MOTORS,FANS GAS BURNERS,IGNITION DEVICES,DRIVES,ETC.SHALL BE - COLD WATER(CW) POINT OF CONNECTION INSTALLATION REQUIREMENTS.PROVIDE DUCTWORK,CONNECTIONS,ACCESSORIES,OFFSETS,AND MATERIALS ADJUSTED AND BALANCED TO OPERATE AT SPECIFIED RATINGS AS REQUIRED FOR THIS PROJECT SITE AND ACCOUNTING FOR ELEVATION ABOVE SEA LEVEL. HOT WATER(HW),POTABLE,120"F O O NECESSARY FOR A COMPLETE SYSTEM, 8. APPROVALS:MECHANICAL AND PLUMBING EQUIPMENT SHALL BE APPROVED FOR INSTALLATION IN THE PROJECT -- -140 HOT WATER,POTABLE, RD OD ROOF DRAIN,OVERFLOW DRAIN LOCATION AND SHALL HAVE ALL CERTIFICATIONS AND RATINGS TO MEET ALL ENERGY,POLLUTION, TEMPERATURE OTHER THAN 120°F APPLICABLE CODES ENVIRONMENTAL,SEISMIC,APPLICABLE CODES AND REGULATIONS.THE CONTRACTOR SHALL COORDINATE WITH FLOOR DRAIN MANUFACTURE SUPPLIERS AND SHALL INCLUDE ALL COSTS REQUIRED TO MEET THE BID DOCUMENTS. --- HOT WATER CIRCULATING(HWC), \ 04 9. FIRE PROTECTION:CONTRACTOR SHALL PROVIDE A FULLY DESIGNED FIRE PROTECTION SPRINKLER SYSTEM IN -f HOSE BIBB THE FOLLOWING PROJECT DESIGN IS BASED ON THE FOLLOWING CODES: 00 POTABLE,120'F N COMPLIANCE WITH NFPA AND LOCAL CODES.PROVIDE DESIGN,PERMITS,MATERIALS,INSTALLATION,TESTING AND ----140- HOT WATER CIRCULATING,POTABLE, ALL OTHER FOR A FULLY OPERATIONAL SYSTEM.LOCATION OF ALL PIPING TO BE COORDINATED WITH OTHER TEMPERATURE OTHER THAN 120°F BREAK IN PIPING OR DUCTWORK -2018 INTERNATIONAL BUILDING CODE(IBC)&WASHINGTON STATE AMENDMENTS -2018 INTERNATIONAL MECHANICAL CODE(IMC)&WASHINGTON STATE AMENDMENTS Q o TRADES. FOF FUEL OIL FILL 11 -2018 UNIFORM PLUMBING CODE(UPC)&WASHINGTON STATE AMENDMENTS CITY OF ARCING ll:., U w 10. PRIOR TO PIPING INSTALLATION:PLUMBING CONTRACTOR TO COORDINATE PIPING LAYOUT WITH ALL OTHER FOS FUEL OIL SUPPLY ( GAS METER -2018 WASHINGTON STATE ENERGY CODE(WSEC) BUILDING DEPARTMENT C TRADES. C45M� INLINE WATER METER 0 N m 11. ACCESS:COORDINATE ALL ACCESS LOCATIONS WITH GENERAL CONTRACTOR AND ARCHITECT TO ENSURE ALL FOR FUEL OIL RETURN D RAW I N G INDEX /, REQUIRED ACCESS HATCHES,ACCESS PANELS&ACCESS COVERS ARE PROVIDED. _ DATE gy /�� c w Q} -FOV- - FUEL OIL VENT PUMP NO CHANGES AUTHORITHp -� -� x p 12. PROVIDE&INSTALL WATER TIGHT SEALS FOR ANY PIPING PENETRATING THE EXTERIOR FOUNDATION WALLS OR - RV- RELIEF VENT I-00 BUILDING INSPECTOR Q Q O z SLABS. Y PRESSURE GAUGE o Z 13. ANY DISCREPANCIES SHOULD BE REPORTED TO THE ARCHITECT IMMEDIATELY. G LOW PRESSURE NATURAL GAS 1 w>a MPG MEDIUM PRESSURE NATURAL GAS THERMOMETER 14. PROVIDE&INSTALL FIRE PROOFING FOR ALL PIPING PENETRATING FIRE BARRIER WALLS OR FLOOR SLABS. Drawing Index - U IRR IRRIGATION(NON POTABLE) -r PIT PRESSURE/TEMPERATURE TEST PORT Z L Z Z DISINFECTION OF POTABLE WATER SYSTEM REQUIREMENTS L n� O O 1. NEW OR REPAIRED POTABLE WATER SUPPLY SYSTEMS SHALL BE DISINFECTED PRIOR TO USE. Sheet Number Sheet Title REDUCED PRESSURE BACKFLOW € V) O 2. INITIAL COLIFORM SAMPLE IS REQUIRED PRIOR TO ADMINISTERING WATER-CHLORINE SOLUTION. RPBP PREVENTER 0. _ Z Po LEGEND,GENERAL NOTES,AND DRAWING INDEX X Uj N ~~ W 3. SECTION 609.9 ITEMS#2 OR#3 CAN BE USED PRECEDED BY AND FOLLOWED BY ITEM#1. ---pQ\�\�� DOUBLE CHECK VALVE ASSEMBLY LIJ 3.1. NOTE FILL PORT TO ADD CHLORINE MUST BE WHERE WATER SUPPLY ENTERS BUILDING AND A FLOW METER TO DCVA P0.1 PLUMBING NOTES AND TABLES X MEASURE SOLUTION. CATCH BASIN P0.2 PLUMBING CALCULATIONS&SCHEDULES X Z 4. AFTER WATEROCHLORINE SOLUTION IS INCORPORATED INTO THE NEW OR REPAIRED WATER SUPPLY SYSTEM A 48 HOUR WAITING PERIOD MUST BE OBSERVED PRIOR TO BACTERIOLOGICAL TEST. I I I I TRENCH DRAIN P0.3 PLUMBING SCHEDULES X Z 5. BACTERIOLOGICAL TEST SHALL BE CONDUCTED BY A LABORATORY CERTIFIED FOR DRINKING WATER IN STATE W AFFIRMING WATER QUALITY CONTAINS NO COLIFORM BY SAMPLE TESTING THE FURTHEST FIXTURE FROM PUBLIC -��F EMERGENCY GAS SHUT-OFF VALVE P2.0 UNDERSLAB WASTE&VENT PLAN X WATER SOURCE AND NOT LESS THAN TWO OTHER LOCATIONS PART OF THE WATER SUPPLY SYSTEM. GAS SEISMIC SHUT-OFF VALVE �1 LEVEL 1 WASTE&VENT PLAN X 6. CHLORINE LEVEL IN THE NEW OR REPAIRED WATER SUPPLY SYSTEM SHALL NOT BE LESS THAN THE MEAN AVERAGE OF THE AREA IN RELATIONSHIP FROM THE WATER PURVEYOR SOURCE. P3.0 UNDERSLAB SUPPLY PLAN X 7. WARNING:IN CASE A WATER SOFTENER IS PART OF THE COLD WATER SYSTEM,CONTRACTOR TO ENSURE THE F-71 WASHER BOX P3.1 LEVEL 1 SUPPLY PLAN X LEGEND,GENERAL WATER SOFTENER IS CONNECTED AND OPERATIONAL BEFORE STARTING THE DISINFECTION PROCESS.FAILURE TO NOTES,AND FOLLOW THE INSTRUCTIONS WILL VOID THE WATER HEATER OR HEAT PUMP WARRANTY. ® GREASE INTERCEPTOR P4.0 WASTE&SUPPLY DIAGRAMS X DRAWING INDEX P6.0 DETAILS X P6.1 DETAILS X Received NOV 3 0 2023 P O.O U7,G-17& PLUMBING TABLES PLUMBING NOTES 1. CONNECTIONS:PROVIDE PLUMBING FIXTURE CONNECTIONS TO BUILDING WASTE,VENT,COLD WATER,AND HOT WATER SYSTEM IN ACCORDANCE WITH 23. REDUCERS:PROVIDE AS REQUIRED FROM LINE PIPE SIZE TO EQUIPMENT, DRAWINGS,MANUFACTURER'S RECOMMENDATIONS,AND LOCAL CODES. TRAP,COIL,AND CONTROL VALVE CONNECTION SIZES. CONNPLUMBING FIXTURE FLOW RATES PER WAC 51-56-0400 VALVE,VACUUCT TO BREAKERS REGULATORS, S,UNIONSC.WITH ALL ACCESSORIES, VALVES,VACUUM BREAKERS,REGULATORS,UNIONS,ETC.AS REQUIRED AND 24. VALVE TAGS:PROVIDE VALVE TAGS PER SPECIFICATIONS TO IDENTIFY VALVE AS RECOMMENDED BY THE MANUFACTURERS.REFER TO PLUMBING FIXTURE AND THE AREA IT SERVES. Z N O CONNECTION SCHEDULE ON PLANS. F O 25. OFFSETS:PROVIDE FOR BRANCH LINES TO EQUIPMENT. a D FIXTURE TYPE MAXIMUM FLOW RATE NOTES HANGER SPACING FOR 2. HOT AND COLD:WATER PIPING CONNECTION TO EACH FIXTURE SHALL BE U w WASTE AND VENT PIPING SIDE. WATER ON THE RIGHT HAND SIDE AND HOT WATER ON THE LEFT HAND 26. SALL TANDARD9ATORE MIXING VALVES SHALL COMPLY WITH ASSE-1070 SAFETY w w p SHOWERHEADS 1.8 GPM @ 80 PSI 1 LAVATORY FAUCETS,RESIDENTIAL 1.2 GPM @ 60 PSI 2 ALL SUSPENDED SANITARY AND VENT PIPE SHALL BE SUPPORTED AS 3. HOT WATER:NON-CIRCULATING HOT WATER PIPE SHALL NOT EXCEED 10, 27. PROVIDE PIPE MARKER WITH DIRECTION OF FLOW.LABEL"NON-POTABLE LAVATORY FAUCETS,PUBLIC&NON-RESIDENTIAL 0.5 GPM @ 60 PSI 3 FOLLOWS PER 2018 UPC TABLE 313.3: UNLESS OTHERWISE SHOWN ON DRAWINGS. WATER DO NOT DRINK"CLEARLY ON NON-POTABLE WATER PIPING. MAX.HORIZ. MAX.VERT. p METERING FAUCETS 0.25 GALLONS PER CYCLE 3 SPACING SPACING 4. VENT STACKS:COORDINATE VENT STACK WITH HVAC EQUIPMENT TO MAINTAIN 28. PROVIDE EXPANSION LOOPS/EXPANSION JOINTS IN PIPING PER 2018 UPC SINKS 2.2 GPM @ 60 PSI 4 ASS 4 FT. 10 FT. MINIMUM 10'CLEARANCE FROM OUTSIDE AIR INTAKES. TABLE 313.3 AND MANUFACTURER INSTALLATION INSTRUCTIONS. KITCHEN FAUCETS 1.8 GPM @ 60 PSI 5 CAST-IRON HUBLESS' EVERY OTHER 15 FT. 5. CLEANOUTS:PROVIDE CLEANOUTS PER CURRENT UPC AND AS REQUIRED BY 29. PROVIDE APPROVED PIPE HANGERS&PIPE SUPPORTS IN ACCORDANCE WITH p PRERINSE SPRAY VALVES 1.6 GPM @ 60 PSI 6 JOINT LOCAL JURISDICTIONS.CLEANOUTS SHALL BE LOCATED IN WALLS/FLOORS MANUFACTURER'S INSTALLATION INSTRUCTIONS AND 2018 UPC TABLES 313.3& Z PVC(TYPE DWV) 4 FT. 10 FT. WHERE THEY ARE NOT HIGHLY VISIBLE.FLOOR CLEANOUTS IN CARPETED 313.6.SUBMIT FOR APPROVAL. GRAVITY TANK-TYPE WATER CLOSETS 1.28 GALLONS/FLUSH 'CAST-IRON OVER 4'SHALL BE SUPPORTED AT EVERY JOINT AREAS TO BE FITTED WITH CARPET INSERTS.LOCATIONS SHALL BE SUBMITTED FLUSHOMETER TANK WATER CLOSETS 1.28 GALLONSIFLUSH FLUSHOMETER VALVE WATER CLOSETS 1.28 GALLONS/FLUSH TO ARCHITECT FOR E PLUMBING DRAWINGS.APPROVAL. OVAL.NOTE:NOT ALL CLEANOUTS ARE SHOWN ON 30. DIELECTRIC UNIONS:PROVIDE AT CONNECTIONS OF DISSIMILAR PIPE. OO�p o?C SOO 31. CONDENSATE DRAIN:PROVIDE A P-TRAP FOR EACH HVAC UNIT CONDENSATE ,O F, p ELECTROMECHANICAL HYDRAULIC WATER CLOSETS 1.28 GALLONS/FLUSH 6. SHUT-OFFS:PROVIDE 1/4 TURN BALL VALVE ANGLE STOP SHUT-OFF VALVES PAN WITH PLUG TEES FOR CLEANING.CONDENSATE DRAINS SHALL BE 00'�_.�!ol O URINALS,WALL MOUNTED 0.125 GALLONS/FLUSH AND BRAIDED STAINLESS STEEL FLEX CONNECTORS AT HOT AND COLD WATER DISCHARGED TO AN INDIRECT WASTE OR OUTSIDE. P O HANGER SPACING FOR SUPPLY TO EACH FIXTURE.EXCEPTION:PROVIDE SCREWDRIVER STOPS AT N URINALS,OTHER 0.5 GALLONS/FLUSH WATER PIPING BATH/SHOWERS. 32. PIPING&EQUIPMENT SUPPORTS/HANGERS&SEISMIC RESTRAINTS TO BE .p sri EO NOTES: DESIGNED BY DESIGN BUILT CONTRACTOR. 00 ....�" ALL SUSPENDED WATER SUPPLY PIPE SHALL BE SUPPORTED 7. TRAP ARMS:PROVIDE TRAP ARMS SUCH THAT THE MAXIMUM LENGTH WILL (1)WHEN A SHOWER IS SE VED B ONE OR MORE AND/OR SHOWER INCLUDING CONTROLLED BY A SINGLE VALVE AS FOLLOWS PER 2018 UPC TABLE 313.3: NOT EXCEED CODE REQUIREMENTS. 33. IF NEEDED,PROVIDE VACUUM BREAKERS AT ALL HOSE BIBBS. COMBINED FLOW RATE OOOp 11 5'23 SHALL NOT EXCEED 1.8 GPM @ 80 PSI. MAX.HORIZONTAL MAX.VERTICAL 8. ADA INSULATION:AT PLUMBING PIPING EXPOSED UNDER LAVATORIES, 34. FLOOR DRAINS OR SIMILAR TRAPS DIRECTLY CONNECTED TO THE DRAINAGE SPACING SPACING INSULATE THE EXPOSED PIPING AND TRAPS WITH PRODUCT SPECIFICALLY AND SUBJECT TO INFREQUENT USE SHALL BE PROVIDED WITH AN APPROVED (2)WHEN INSTALLED IN COMMON&PUBLIC USE AREAS(OUTSIDE OF DWELLINGS OR SLEEPING UNITS)IN COPPER PIPE<1 z" 6 FT. 10 FT. DESIGNED FOR THIS APPLICATION MEETING ADA REQUIREMENTS.PROVIDE AUTOMATIC MEANS OF MAINTAINING THEIR WATER SEALS IN ACCORDANCE RESIDENTIAL BUILDINGS,FLOW RATE SHALL NOT EXCEED 0.5 GPM @ 60 PSI COPPER PIPE>2" 10 FT. 10 FT. HANDI-LAV GUARD OR EQUIVALENT.OFFSET P-TRAPS TO CLEAR WHEELCHAIR WITH 2O18 UPC 1007.0. (3)LAVATORY FAUCETS LOCATED IN RESTROOMS INTENDED FOR USE BY THE GENERAL PUBLIC SHALL BE COPPER TUBING< 2" 6 FT. 10 FT. ACCESS. EQUIPPED WITH A SELF-CLOSING METERING VALVE WHEN LEFT UNATTENDED.EXCEPTION:WHERE DESIGNED AND COPPER TUBING>2" 10 FT. 10 FT. 35. INSULATION MATERIAL SHALL MEET CITY OF ARLINGTON QUALITY STANDARDS. INSTALLED FOR USE BY PERSONS WITH A DISABILITY.EXCEPTION:WHERE INSTALLED IN DAY CARE CENTERS,FOR CPVC<1" 3 FT. 10 FT. 9. GAS EQUIPMENT:GAS EQUIPMENT SHALL BE INSTALLED PER EQUIPMENT USE PRIMARILY BY CHILDREN UNDER 6 YEARS OF AGE. CPVC>14" 4 FT. 10 FT. LISTINGS,APPLICABLE IFGC,UPC,LOCAL CODES&NFPA STANDARDS. 36. ALL PIPING AND DUCTWORK SHALL BE INSULATED CONSISTENT WITH THE 2018 RO I O (4)EXCEPTION:CLINICAL SINKS,LAUNDRY TRAYS,SERVICE SINKS 10. GAS CONNECTIONS:INSTALL FLEXIBLE QUICK DISCONNECT ASSEMBLIES FOR WA STATE ENERGY CODE. 5 KITCHEN FAUCETS MAY TEMPORARILY INCREASE FLOW ABOVE THE MAXIMUM FLOW RATE,BUT NOT ABOVE 2.2 ALL GAS FIRED KITCHEN EQUIPMENT PER APPLICABLE IFGC,UPC,LOCAL 37. BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH 2O18 UPC ENGINEERING,INC O GPM @ 60 PSI AND MUST DEFAULT TO A MAXIMUM FLOW RATE OF 1.8 GPM @ 60 PSI.AERATORS OR OTHER MEANS CODES&NFPA STANDARDS.PROVIDE LOCKABLE GAS SHUT-OFF VALVES FOR 701.0 AND 903.0. iemiamBnvew,sa-20D,wa 96036 MAY BE USED TO ACHIEVE REDUCTION. FIREPLACES&BBQS IN UNATTENDED PUBLIC LOCATIONS IN THE BUILDING. 2063 343mti 38. ALL SANITARY SYSTEM MATERIAL SHALL BE LISTED BY AN APPROVED LISTING pn ac�r crrEeDreac2i"A (6)PRERINSE SPRAY VALVES SHALL BE EQUIPPED WITH AN INTEGRAL AUTOMATIC SHUTOFF. 11. GAS PIPING CONNECTIONS TO WATER HEATERS,BOILERS AND FURNACES AGENCY. SHALL HAVE DIRT LEGS AND UNIONS PROVIDED ON APPLIANCE SIDE OF SHUTOFF VALVE. 39. ALL STORAGE WATER HEATING EQUIPMENT SHALL BE PROVIDED WITH AN APPROVED,LISTED EXPANSION TANK OR OTHER DEVICE DESIGNED FOR 12. GAS PIPING INSTALLATION:STEEL OR MALLEABLE IRON FUEL LINES 2"OR INTERMITTENT OPERATION FOR THERMAL EXPANSION CONTROL PER 2018 UPC O O 0 SMALLER SHALL BE ASSEMBLED USING THREAD SEALANT SUITABLE FOR 608.3. NATURAL GAS.GAS PIPING LARGER THAN 2"SHALL HAVE WELDED FITTINGS. Y 40. WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST HORIZONTAL 13. GAS PIPING ABOVE GROUND:WHERE PASSING THROUGH AN OUTSIDE WALL, DISPLACEMENTS DUE TO SEISMIC MOTION PER 2018 UPC 507.2. o GAS PIPING SHALL BE PROTECTED AGAINST CORROSION BY COATING OR i U Y O WRAPPING WITH AN INERT MATERIAL.WHERE PIPING IS ENCASED IN A 41. MATERIAL EXPOSED WITHIN A DUCT OR PLENUM SHALL COMPLY WITH 20181MC O Q: PROTECTIVE PIPE SLEEVE,THE ANNULAR SPACE BETWEEN THE PIPING AND 602.2.1. w x a p p � 2018 WASHINGTON STATE PIPE INSULATION SCHEDULE THE SLEEVE SHALL BE SEALED. 42. HVAC EQUIPMENT AND WATER HEATERS SHALL COMPLY WITH 20181MC 14. GAS PIPE SUPPORT:FUEL LINES SHALL BE SUPPORTED OR STRAPPED,AND CHAPTER 3. SHALL BE PLUMB AND SQUARE. OPTION 1 OPTION 2 43. PLUMBING FIXTURES AND FITTINGS SHALL COMPLY WITH CITY OF ARLINGTON SERVICE VAPOR RETARDER NOTES 15. GAS PIPING SHALL NOT BE BURIED UNDER BUILDING,SLAB OR OTHER WATER CONSERVATION STANDARDS. REQUIRED STRUCTURE. MATERIAL THICKNESS MATERIAL THICKNESS 44. CONTRACTOR SHALL PROVIDE FIRESTOPPING AT PENETRATIONS AS 16. GAS PIPING PROTECTIVE COATING:PAINT ALL EXTERIOR EXPOSED GAS PIPING NECESSARY TO RETAIN THE FIRE RATING OF ALL ASSEMBLIES.ALL WORK DOMESTIC COLD WATER,IRRIGATION WATER,CONDENSATE DRAINS, WITH TWO COATS OF RUST INHIBITIVE PAINT.COLOR:GRAY. SHALL BE IN COMPLIANCE WITH CODE REQUIREMENTS FOR THE BUILDING STORM DRAIN(IN CONDITIONED SPACE) MINERAL-FIBER WITH JACKET ALL SIZES:Yi' PVC/NBR ALL SIZES:3/e" YES 8,9 CONSTRUCTION TYPE. 17. WATER HAMMER ARRESTORS:PROVIDE AT THE END OF HOT AND COLD WATER DOMESTIC COLD WATER,IRRIGATION WATER,CONDENSATE DRAINS, (R-3) (R-3) LINES SERVING TWO OR MORE FIXTURES;SIZE IN ACCORDANCE WITH 45. PLUMBING CONTRACTOR SHALL PROVIDE REDUCED PRESSURE BACKFLOW PLUMBING AND DRAINAGE INSTITUTE(PDI)REQUIREMENTS.WATER HAMMER PREVENTERS OR OTHER APPROVED BACKFLOW PREVENTION DEVICE WHERE WASTE(OUTSIDE THE CONDITIONED SPACE) MINERAL-FIBER WITH JACKET Y2"PIPE:Y2" PVC/NBR Y2"PIPE:Y2" YES 4.5,7 ARRESTORS ARE REQUIRED FOR QUICK CLOSING VALVES,SUCH AS LAUNDRY REQUIRED BY HEALTH AUTHORITIES,FOOD SERVICE DRAWINGS,APPLIANCE ALL OTHER SIZES:1" ALL OTHER SIZES:3/a" WASHERS,FLUSH VALVES(PUBLIC TOILETS),ETC. MANUFACTURER INSTRUCTIONS AND BY CODE. M W N DOMESTIC HOT WATER AND RECIRCULATED HOT WATER Y2"-1Y4 Y2"PIPE:1" "-1Y4"PIPE:1" 18. TRAP PRIMERS AS SPECIFIED:PROVIDE TRAP PRIMERS AND PIPING FOR FLOOR PROVIDE REQUIRED&PROPER BACK FLOW PREVENTERS AS SPECIFIED FOR U- N MINERAL-FIBER WITH JACKET PVC/NBR NO 3,6 00 (NONRESIDETIAL) 1Yz''-4"PIPE:1.5" 1Yi'-4"PIPE:1.5" DRAINS,FLOOR SINKS,AREA DRAINS&HUB DRAINS.ARRANGE PIPING TO THE APPLIANCES INCLUDING,BUT NOT LIMITED TO THE FOLLOWING: � 01 ACHIEVE EQUAL FLOW TO EACH DRAIN AND FLOOR SINK FOR TRAP PRIMERS EXPOSED SANITARY DRAINS AND DOMESTIC WATER SUPPLIES AND SERVING MULTIPLE DRAINS AND FLOOR SINKS.COORDINATE EXACT a. ICE MACHINES AND ICE MAKERS >Q m STOPS FOR ADA FIXTURES. TRUEBRO LAV-GUARD N/A N/A N/A NO 12 LOCATIONS WITH ARCHITECT&ELECTRICAL ENGINEER. b. CARBONATED BEVERAGE DISPENSING SYSTEMS U > H c. COFFEE BREWERS co NOTES: 19. P-TRAPS:ALL EXPOSED P-TRAPS SHALL BE CHROME-PLATED BRASS.P-TRAPS d. ESPRESSO MACHINES C45 N o SERVING HANDICAPPED COUNTER TOP LAVATORIES SHALL BE INSULATED. e. WATER FILTERS 0 m f. STEAM OR HOT WATER BOILERS } ¢3 1. SEE BELOW PLUMBING NOTES FOR APPLICABLE CODES. J a) 20. THROUGHOUT THE PROJECT PROVIDE BALL VALVES.GATE VALVES SHALL NOT g. IRRIGATION SYSTEM 2. PIPING INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FROM DAMAGE.CONTRACTOR SHALL PROVIDE SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL.ADHESIVE TAPE SHALL NOT BE BE USED.NO EXCEPTIONS. h. FIRE PROTECTION SYSTEM p o PERMITTED. L CHEMICAL TREATMENT SYSTEM w L 0`4 3. NOT USED. 21. HOT WATER RECIRCULATING BALANCING VALVES SHOULD BE BELL&GOSSETT j. SOAP/CHEMICAL DISPENSER SYSTEM Q Q o Z o CIRCUIT SETTER(WATTS OR EQUAL)WITH INTEGRAL READOUT PORTS, k. COMMERCIAL WASHER o z_ 4. PER 2018 SECTION E (NON-RESIDENTIAL). ADJUSTMENT KNOB,DRAIN CONNECTION,AND POSITIVE SHUTOFF. v I 0- ^�a 5. PIPING FROOMM W WATER HEATTERR T TO THE TERMINATION OF HEATED WATER SUPPLY PIPE SHALL BE INSULATED IN ACCORDANCE WITH TABLE C403.2.9. _ () 6. ON BOTH THE INLET AND OUTLET PIPING OF A STORAGE HOT WATER HEATER,THE FIRST 8 FEET OF PIPING OR PIPING FROM WATER HEATER TO HEAT TRAP SHALL BE INSULATED. 22. DISASSEMBLY PROVISIONS:PROVIDE UNIONS OR FLANGES AT PIPING J 9 z Z_ 7. HEAT TRACED PIPING SHALL BE INSULATED IN THE SAME MANNER AS NON HEAT TRACED PIPING OR PER HEAT TRACE MANUFACTURER SPEC. CONNECTIONS TO EQUIPMENT,COILS,TRAPS,CONTROL VALVES,AND OTHER L I( COMPONENTS TO ALLOW DISASSEMBLY FOR MAINTENANCE. O O 8. TUBULAR PIPING INSULATION SHALL NOT BE REQUIRED FOR THE FOLLOWING: :_ A. TUBING FROM FROM THE CONNECTION AT THE TERMINATION OF THE FIXTURE PIPING TO A PLUMBING FIXTURE SUPPLY PIPING TO A PLUMBING FIXTURE. (/� O IA Z' B. VALVES,PUMPS,STRAINERS AND THREADED UNIONS IN PIPING THAT IS 1 INCH OR LESS. Lf') {�/f C. PIPING FROM USER CONTROLLED SHOWER AND BATH MIXING VALVES TO THE WATER OUTLET. Q 0 ~~D. COLD WATER PIPING OF A DEMAND RETICULATION WATER SYSTEM m W W E. TUBING FROM A HOT DRINKING WATER UNIT TO THE WATER OUTLET. O Z F. PIPING AT LOCATION WHERE A VERTICAL SUPPORT OF PIPING IS INSTALLED. r G. PIPING SURROUNDED BY BUILDING INSULATION WITH R-VALUE OF NOT LESS THAN R-3. U w Z 9. PER 2018 UPC,SECTION 312.6 NO WATER,SOIL OR WASTE PIPE SHALL BE INSTALLED OR PERMITTED OUTSIDE OF THE BUILDING,IN ATTIC OR IN AN EXTERIOR WALL UNLESS ADEQUATE PROVISION IS MADE TO PROTECT SUCH PIPE FROM VJ FREEZING.ALL HOT AND COLD WATER PIPES OUTSIDE THE CONDITIONED SPACE SHALL BE INSULATED TO MINIMUM R-3. 10. HEAT TRACING SHALL BE PROVIDED FOR COLD WATER AND IRRIGATION WATER IN UNCONDITIONED SPACES.REFER TO HEAT TRACING SCHEDULE FOR DETAIL.CONTACT ENGINEERING IF NECESSARY.PER 2018 WSEC SECTION C403.2.4.6 TE: 11/15/2023 FREEZE PROTECTION SYSTEMS,SUCH AS HEAT TRACING OF OUTDOOR PIPING SHALL INCLUDE AUTOMATIC CONTROLS CONFIGURED TO SHUT OFF THE SYSTEM WHEN OUTDOOR AIR TEMPERATURES ARE ABOVE 40"F. 11. PER 2018 WSEC TABLE C403.2.9(FOR NON-RESIDENTIAL)INSULATION FOR HOT WATER AND HOT WATER RETICULATION SHALL HAVE CONDUCTIVITY OF 0.21-0.28(BTU.IN/H.FT'."F)AT OPERATING TEMPERATURE. 12. INSULATION R-VALUE SHALL MEET MINIMUM REQUIREMENT.THICKNESS IS BASED ON GRAINGER SAMPLE DATA FOR K-FLEX(PVC/NBR)AND OWENS CORNING(FIBER GLASS). SHEET TITLE: 13. ALL ADA P-TRAPS,HOT WATER SUPPLY TUBING AND SHUT-OFF COCKS SHALL BE PROTECTED WITH APPROVED COVERS TO PREVENT SCALDING. PLUMBING NOTES 14. REQUIRED BY ENGINEERING BASED ON BEST PRACTICE. AND TABLES 15. INSULATION IS NOT REQUIRED ON PLASTIC PIPING. SHEET NO. P0. 1 PLUMBING CALCULATIONS PLUMBING SCHEDULES FIXTURE UNIT CALCULATIONS CALCULATIONS BASED ON 2018 UPC APPENDIX A TABLE A103.1&CH.7 TABLE 702.1 FIXTURE UNITS LEVEL TOTAL CITY TOTAL FIXTURE UNITS FIXTURE OF FIXTURES TOTAL CW HW WN 1 SERVICE CW ONLY HW ONLY WN ONLY z WATER CLOSET FLUSH VALVE 5 5 0 4 2 2 10 10 0 8 a 0 PUBLIC LAVATORY 1 0.75 0.75 1 2 2 2 1.5 1.5 2 O w 2"FLOOR DRAIN 0 0 0 2 2 2 0 0 0 4 0 4"FLOOR SINK 0 0 0 8 6 6 0 0 0 48 MOP SINK 3 2.25 2.25 3 1 1 3 2.25 2.25 3 HAND SINK 1 0.75 0.75 1 2 2 2 1.5 1.5 2 0 DUMP SINK 1 0.75 0.75 0 1 1 1 0.75 0.75 0 3-COMP SINK 3 2.25 2.25 0 1 1 3 2.25 2.25 0 DISHWASHER 3 3 0 0 1 1 3 3 0 0 Z 1-COMP SNK 1.5 1.125 1.125 0 1 1 1.5 1.125 1.125 0 PIPE MATERIALS SCHEDULE COMBIOVEN 1 1 0 0 1 1 1 1 0 0 PIPE TYPE MATERIAL JOINT NOTES Opp000ppp GLASS RINSER 1 1 0 0 1 1 1 1 0 0 00 C WATER FILTRATION SYSTEM 1 1 0 0 3 3 3 3 0 0 O J A ks Q, UNDERGROUND WATER DISTRIBUTION PIPING PEX SOLDERED,WELDED,OR PROPRESS (2) SUBTOTAL 30.5 27.375 9.375 67 P p ABOVE GROUND WATER DISTRIBUTION PIPING PEX SOLDERED,WELDED,OR PROPRESS O TOTAL CW MH� WN UNDERGROUND WASTE AND VENT PIPING SCHEDULE 40 PVC OR ABS SOLVENT CEMENT TOTAL FIXTURE UNITS: 30.5 27.375 67 OOp Sg/CN ABOVE GROUND WASTE AND VENT PIPING CAST IRON WASTE WITH ABS VENTS SOLVENT CEMENT OR HUBLESS COUPLINGS (3) PEAK FLOW: 20 GPM ppoD 11,E 5,23 REQUIRED SERVICE SIZE IN BUILDING: (1)1 1/4" (1)4" CONDENSATE DRAIN PIPING COPPER,TYPE M OR CPVC SOLDERED OR SOLVENT CEMENT GREASE INTERCEPTOR CALCULATIONS NATURAL GAS PIPING STEEL PIPE,ASTM A 53:TYPE E OR S;GRADE B;SCHEDULE 40 THREADED,WELDED,OR MEGAPRESS NOTES: CALCULATIONS BASED ON 2018 UPC (1)ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN APPROVED LISTING AGENCY. FIXTURE QUANTITY L W D CU IN. GALLONS FLOW RATE (2)PLASTIC WRAP UNDERGROUND WATER SUPPLY PIPING TO PREVENT CORROSION. OBI SON HAND SINK 2 14 10 10 2633 11 4 ENGINEERING,INC MOPSINK 1 20 16 6 1920 8 3 iswiam-w,.-2 LYNNWO0OWA96036 3-COMP SINK 1 18 18 14 13608 59 22 FEI PFOhC�20636bN30 E36 ..962L26 1-COMP SINK 1 18 18 14 4536 20 7 DUMP SINK 1 14 10 10 1400 6 2 DISHWASHER 1 N/A N/A N/A - - 29 2"FLOOR DRAIN 2 N/A N/A N/A - - 0 PLUMBING FIXTURE SCHEDULE o 0 0 0 4"FLOOR SINK 6 N/A N/A N/A - - 6 Y SERVICE SIZE-INCHES TOTAL FIXTURE FLOW RATE(GPM) 74 PLAN MARK FIXTURE TYPE LOCATION FINISH MANUFACTURERS BASIS OF DESIGN NOTES o CW HW W V Z y O PIPE SIZING FOR PEX PIPE AT 2 PSI/100' WITH HUNTER'S CURVE- FLUSH TANK SIZING WC-1 WATER CLOSET 3/4" 3" 2" PEP�FLNSOR TBD TBD TBD w O U Q 52°COLD WATER 120°HOT WATER 116°RECIRUCLATED LAV-1 FAUCET Y,' )/2" - - PER FLOOR PLANS TBD TBD TBD - WSFU GPM FT/S WSFU GPM FT/S GPM FT/S PER FLOOR LAVATORY - - 2" 1Yz" PLANS TBD TBD TBD - 0.0 1.0 1.8 0.1 1.1 2.0 1.1 2.0 Y" 1.5 2.5 2.3 1.9 2.9 2.6 2.2 2.0 FCO-1 CLEANOUT - - - - NOTE 1 IRON/BRASS WATTS CO-260 8"GASKET 1" 6.0 5.0 2.8 6.6 5.6 3.1 3.6 2.0 1%" 11.3 8.7 3.2 12.7 9.7 3.6 5.4 2.0 NOTES: 1 Y." 19.1 13.5 3.6 21.9 15.1 4.0 7.6 2.0 (1)CONTRACTOR TO INSTALL AS REQUIRED BY CODE 2" 47.6 28.0 4.3 55.4 31.2 4.8 13.0 2.0 2 Y." 121.5 49.3 5.0 122.3 49.5 5.0 19.8 2.0i-- M 3" 271.6 79.3 6.6 227.6 70.6 5.0 28.2 2.0 W N u- OD 01 PRESSURE CALCULATION DRAIN SCHEDULE U CALCULATION BASED ON 2018 UPC APPENDIX A H SERVICE SIZE m ro MINIMUM PRESSURE AT BACKFLOW PREVENTOR,PSI 45 N o EQUIP NO. LOCATION FIXTURE TYPE FINISH MANUFACTUER BASIS OF DESIGN NOTES O6 PER BACKFLOW ASSEMBLY TEST REPORT,05/09/23 W V w a d FS-1 PER FLOOR PLANS NOTE 2 NOTE 2 FLOOR SINK N/A JAY R.SMITH 310Y (3) o J C x d PIPING FRICTION LOSSES w L 00 FD-1 PER FLOOR PLANS NOTE 2 NOTE 2 FLOOR DRAIN NICKEL BRONZE SIOUX CHIEF 833 (3) Q Q 3 w PIPING SYSTEM LENGTH,FEET 250 Z O rn a FITTING ALLOWANCE,FEET 62.5 NOTES: _ V FROM BACKFLOW TO FURTHEST FIXTURE (1)CONTRACTOR SHALL CONFIRM MAKE,MOOEL,AND FINISH OF ALL FIXTURES WITH OWNER,ARCHITECT,AND INTERIOR DESIGNER PRIOR TO ORDERING. J Q Z Z (2)SIZE PER PLANS ZONE FRICTION LOSS FACTOR,PSI/100' 2.0 (3)INSTALL FLUSH WITH FINISHED FLOOR. O {jI ) Z TOTAL ZONE FRICTION LOSS,PSI 6.25 Q "-y re w � MINIMUM PRESSURE AT FURTHEST FIXTURE,PSI mW 38.8 �l.� Z HOT WATER HEATER CALCS W - 1) HOURLY HOT WATER DEMAND TABLE(GPH) Z HAND SINK 6 GALLONS PER SINK W MOP SINK 8 GALLONS PER SINK 3-COMP SINK 20 GALLONS PER COMPARTMENT 1-COMP SINK 20 GALLONS PER COMPARTMENT TE: 11�15�2023 DUMP SINK 6 GALLONS PER SINK PUBLIC LAVATORY 5 GALLONS PER LAVATORY SHEET TITLE: 2) FIXTURE QUANTITY GPH TOTAL GPH REQ'D PLUMBING HAND SINK 2 6 12 MOP SINK 1 8 8 CALCULATIONS& 3-COMP SINK 1 60 60 t HEDULES 1-COMP SINK 1 20 20 DUMP SINK 1 6 6 PUBLIC LAVATORY 2 5 10 TOTAL 116 3) WATER HEATER SIZE CALCULATION: SHEET N0. 1 INSTANTANEOUS WATER HEATER PROVIDED,CAPABLE OF PROVIDING 288 GPH @ 68°F RISE. ^O.^ PLUMBING EQUIPMENT SCHEDULES WATER HEATER HEATEXCHANGER INLET/OUTLET GAS OPERATING EQUIP NO. SERVICE FUEL THERMAL GPH RECOVERYAT WEIGHT ELECTRICAL BASIS OF DESIGN NOTES z N SOURCE INPUT(MBH) EFFICIENCY 68°F CONNECTION CONNECTION (LBS) 0 F z 0 a � > U W WH-1 HOT WATER NAT.GAS 199.9 0.82 288 3/4" 3/4" 60 120VAC,MAX 2 wAMPS NORITZ NC199DVC 1 p NOTES: (1)PROVIDE CONCENTRIC VENT KIT p (2)INSTALL IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS. (3)ALL DOMESTIC WATER EQUIPMENT SHALL BE NSF-61 LISTED. O Z HOT WATER CIRCULATION PUMP 0000❑❑Ac E 000 ELECTRICAL A �p NO PRESSURE WEIGHT, pO�v:'pvaas SERVICE TYPE FLOW,GPM HEAD,FT PUMP RPM BASIS OF DESIGN NOTES NO. RATING,PSI LBS O P ❑❑ VOLTAGE HP ❑ h O HWCP-1 HOT WATER RECIRCULATION INLINE 1 5 1474 150 115V/iP - 7 BELL&GOSSETT-ECOCIRC 19-16 1 oo��Sso�oao �3 NOTES: (1)ALL BRONZE,MAINTENANCE FREE,SUITABLE FOR POTABLE WATER APPLICATION. (2)INSTALL IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS. (3)ALL DOMESTIC WATER EQUIPMENT SHALL BE NSF-61 LISTED. EXPANSION TANK ROBISON TANK SIZE ENGINEERING,INC OPERATING WEIGHT isnoiamHnvew,6ni—2 EQUIP NO. SERVICE CAPACITY(GAL) BASIS OF DESIGN NOTES LPNNW 0 WA9B036 DIAMETER(INCHES) HEIGHT(INCHES) (LBS) 206-3E3- FEI -NO..96- ET-1 DOMESTIC HOT WATER 2 8 13 281 AMTROL ST-5 1,2 NOTES: z z 0 (1)INSTALL IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS. O 0 0 (2)ALL DOMESTIC WATER EQUIPMENT SHALL BE NSF-61 LISTED. Y o z TRAP PRIMER ui w U w =<Ea p O U ¢ EQUIP SERVICE INLET/OUTLET CONNECTION DIMENSIONS(D"x H") BASIS OF DESIGN NOTES NO. TP-1 FLOOR DRAINS Y2"/Y2" 1%"x43%" PRECISION PLUMBING PRODUCTS MP-500-115V 1 NOTES: (1)NSF-61 COMPLIANT GREASE INTERCEPTOR M EQUIP NO. SERVICE FLOW RATE(GPM) GREASE CAPACITY LIQUIDS CAPACITY WEIGHT(LBS) CONNECTION BASIS OF DESIGN NOTES w CV (LBS) (GAL) SIZE 00 GI-1 GREASE WASTE 75 175 40 404 4" SCHIER GB-3 1,2,3 Q CT Q N > O NOTES: > w F (1)INSTALL IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS. (2)OR EQUIVALENTLY APPROVED. (3)PROVIDE SCHIER SV10 SAMPLING PORT. _C'6 O W J a3M C xdl REDUCED PRESSURE BACKF Z ZLOW ASSEMBLY Q z o EQUIP NO. SERVICE INLET/OUTLET SIZE BASIS OF DESIGN NOTES V Z Zz RPBP-1 DISHWASHER Y2"1Y2" ZURN WILKINS 375XLB 1,2 O O RPBP-2,3,4 WATER FILTER SYSTEM Y2"1Y2" ZURN WILKINS 375XLB 1,2 Q U) Z NOTES: {/�'Jy/~~f�J (1)MEETS AWWA C551-92 STANDARDS. w O W (2)ALL DOMESTIC WATER EQUIPMENT SHALL BE NSF-61 LISTED. r O w GAS PRESSURE REGULATOR9 Z w EQUIP NO. SERVICE MAX INLET MIN INLET OUTLET PRESSURE CAPACITY(MBH) MAX INDIVIDUAL LOAD ORIFICE SIZE BASIS OF DESIGN NOTES TE: 11/15/2023 PRESSURE PRESSURE (MBH) GPRV-1 PER PLANS 2 PSI 1 PSI T'WC 500 425 1" MAXITROL 325-5L 1,2 SHEET TITLE: PLUMBING NOTES: SCHEDULES (1)PROVIDE APPROVED VENT LIMITING DEVICE OR VENT TO EXTERIOR SIZED TO MATCH VENT CONNECTION ON REGULATOR.VENTS ARE NOT SHOWN ON THE PLANS. (2)STEPDOWN REGULATORS MUST BE AT 4 FEET AFF. SHEET NO. P0.3 Z 0 O F ap D) > N W w � SHEET NOTES: 1. Waste&Vent Sizing:waste&vent piping sized per 2018 d 5 16.7 7 17.5 8 UPC Table 703.2.Piping 4"and larger shall be sloped atY8" Z per foot with approval of AHJ.Piping smaller than 4"shall be sloped at Y4"per foot: boo°�o Ae s°o� peviasy PIPE SIZE VERT. HORIZ. VENT 1y2'' 2 FU 1 FU 8 FU J'___FF 2" 16 FU 8 FU 24DFU C 3" 48 FU 35 FU 84 FU °°ossi 4" 256 FU 172 FU 256 FU °pOoao 15 23 i 9� 6rvEL�ND ° „ oFsr RE,A6E 6rvEL�rv� ORDER � 6" 1,380 FU 576 FU 1,380 FU 11� TRA6H 8" 3,600 FU 2,112 FU 3,600 FU DINING IF ROOM 2. Provide floor and wall cleanouts as required by code. DELI 2'G O.°w 3. Provide trap primers for all floor drains per 2018 UPC 1007.1.G ROBISON = - a.. V_GW See Detail 2/P6.0. ENGINEERING,INC 3"GW ( V3 i9wi mrDAvew,.1— LYNNWOOD,WA96036 FLAG NOTES: D636633E3 n pE - ___3"G FNIT JECN0.:962L29 W G GW I VYI 1. 4"SS point of connection to existing sanitary sewer. a"s 2. WC-1 underslab waste piping.Architect to verify fixture z z za°ss 0 0 0 v2° location. c 3. GI-1 sample box. Y D 1v2"v 3„ b d� G z V D PICK-UP 3 W GW2„GW z3 X O (37 3 °. o---_ 3�VJ M —o W =U Ld a � O Q EE1/'vI 3 � o GI-1 S-C L LOUNGE 3 O �i OU F GW 4 G G - 2 07 O 3"SS I 3' 3"SS LL 00 (ARC IV TO .a O` FDRY FY) FY) STORAGE F N 5 U 3 0 unnnn courvrea 2"SS o `iV 0 rn m t Q G J � a3ccOn C xd� w Q 800 w oZz � o � rn�a Z Zz � 0 0 _ z_ 5 7 8 Q o -- W 04 m LO W 0 z z W TE: 11/15/2023 SHEET TITLE: UNDERSLAB WASTE &VENT PLAN UNDERSLAB WASTE&VENT PLAN ( Y SCALE:1/4"-1'-0" J SHEET NO. P2.0 Z 0 O F ap D) 5 N W w � SHEET NOTES: 1. Waste&Vent Sizing:waste&vent piping sized per 2018 z 5 16.7 7 17.5 8 UPC Table 703.2.Piping 4"and larger shall be sloped atY8" per foot with approval of AHJ.Piping smaller than 4"shall be poopp sloped at Y4"per foot: oo�o J AC soo PIPE SIZE VERT. HORIZ. VENT o 1Y2" 2 FU 1 FU 8 FU JE7 2" 16 FU 8 FU 24DFU ooR s„ Eo C 3" 48 FU 35 FU 84 FU 4" 256 FU 172 FU 256 FU °000pp 15 23 i 9 EL IrvD ° „ oFsr RE,a6E ELVIrv" ORDER a 6" 1,380 FU 576 FU 1,380 FU 11 �6ry 3"FS-1 F 8" 3,600 FU 2,112 FU 3,600 FU DINING > I ROOM ' 2. Provide floor and wall cleanouts as required by code. DFrLOD- __� 1/2° 3. Provide trap primers for all floor drains per 2018 UPC 1007.1. ROBISON ---- — See Detail 2/P6.0. __S6_sa_a ENGINEERING,INC � 3/a'CD i9noiamDnvEw,wrtE3c 1Y"V a LYNNWOOD T 0 ^ 20636b33E3�36 %"Co CD — 1 'V FLAG NOTES: P 2L26 L , FEI0.:96 CO-T I ��3(a6D „ �I K 3 ES_i 1. Existing 4"V to roof. �I �s 2. Walk-in cooler evaporator.Equipment shown for reference z z PREPN only. 0 0 0 0 ' COOK 3. Walk-in freezer evaporator.Equipment shown for reference Y 2"FD-1 only. n 4. 2"V;wet vent for WC-1.Architect to verify fixture location. Z Y 'o PICK-UP 1Vv 31. 5. 2"V for WC-1.Architect to verify fixture location. < W = a O 3'V 1 ,7 3°F_°o 7 LOJ I 6. GI-1 pedestrian rated cover. 0 0 0 a 7. FC sample box cover. r--1 � 8. FCU-1.Mechanical equipment shown for reference only.See I s mechanical plans for more detail. SC 9. FCU-2.Mechanical equipment shown for reference only.See tans for more detail. ?I L--J LOUNGE [" mechanical p in l 3 10. Provide 5 "Nortiz concentric stainless steel pipe to outdoors. - I � Terminate with required clearances to operable windows, O I a 2,v— __1Y2" _ doors and OSA intakes. UOD I � - WG1 I i WC-1 Cl) EN'S I WOMEN' s o w04 (ARCH TO I (AR TO IpRAGE < CD Q < F UC n nV RIFY) I VERS1`H) F Q O m courvrea T Qx m 0 v V O i�E� rnm t Q G J c =o� D LJJ 800 Q 3:6' IO pZZ 0 V) d rn E Z D Zz � 0 0 _ z_ 5 7 8 Q o 0 0 W c`nv m W W O Z W TE: 11/15/2023 SHEET TITLE: LEVEL 1 WASTE& VENT PLAN LEVEL 1 WASTE &VENT PLAN SCALE'.1/4"-V-0" ` SHEET NO. 1 SHEET NOTES: 1. Provide expansion loops for all water piping per the manufacturer's instructions.See Detail 2/P6.0. z 0 F 0 2. Provide trap primers for all floor drains per 2018 UPC 1007.1. a See Detail 5/P6.0. w 0 0 5 (6.7 7 17 5 8 Z °ppOopp�p 00 J A C °oQ F,o...._..._kS, `b of �, ... C3 T--FF °o p sn Eo C ooOossia� g 6 d E N� osPar E E N� ORDER �o0 11 15 23 II (FUTURE)A6 u RA6N DINING IF ROOM 3%-cw DELI A' TP1 ROBDSON ENGINEERING,INC sno,amHnvew,wrtE3cz 36"cw 200-3E3� KITCHEN PREP/ 0 0 0 0 �r COOK Y V3 D Cw Do O PICK-UP M w a U O SCULLERY LOUNGE -7 TE, I �� O . O O M O wN EN'S WOMEN'S DRY LL ONO (ARCH TO (ARCH TO STORAGE 01 F VERIFY) VERIFY) OFQ UC In In In n U < F COUNTER N Ell 0 kWWI o M ?rnm t Q G J a3M C 0 0 o Q LU Q o()o w pzzo� rn a Z Z z � 0 0 _ z_ 5 7 8 Q o I--I rX LU C`NN m W W Oz z W VTE: 11/15/2023 SHEET TITLE: UNDERSLAB SUPPLY PLAN UNDERSLAB SUPPLY PLAN (OY� SCALE:1/4"-V-0" J SHEET NO. P3.0 SHEET NOTES: 1. Provide expansion loops for all water piping per the manufacturer's instructions.See Detail 2/P6.0. Z o F p 2. Provide trap primers for all floor drains per 2018 UPC 1007.1. See Detail 5/P6.0. w 0 3. Provide MV-1 thermostatic mixing valves and set to 120T in all public lavatories and kitchen handwashing sinks.See Detail H 7/P6.0. 4. Provide vents to outdoors for regulators per local jurisdiction o 5 16.7 7 (7.5 8 and NFPA-54.Routing of vents is not shown on the plans. Z 5. Mount Reduced Pressure Backflow Preventers where o 10 Ac accessible for testing' ° ,ee�uasy� FLAG NOTES: o C 1. 2"CW point of connection from existing water meter. °000sy d' 2. Provide RPBP-1 on CW line to dishwasher. °p❑❑❑❑ 15,23 i 9 d EL°Iry osPa° E EL Irv„ 4 ORDER 3. Provide RPBP-2 on CW line to water filtersystem. 11' � T— , 4. Provide RPBP-3 on CW line to water filter system. DINING _ ::�l 5. Provide RPBP-4 on CW line to water filter system. ROOM 6. 3/4"CW line for WC-1.Architect to verify fixture location. DELI 3 :; u; 7. Provide GPRV-1 pressure regulator set to 7"WC outlet cW pressure,vented to exterior. e — _' 1"cW 8. %z"MPG point of connection from existing gas meter. ROBISON Y4"CW A; 1„CW ENGINEERING,INC ,9w,4or„n wrt "CW LYNNWD—31 96036 20636b3343- 4"HW —NO CO— .. 1-CW - 111cw- - L—__—� 1%4''CW 3" PREP/ 0 0 0 � COOK Y D ,ti.. D PICK-UP 4 Hw...,., c Y o U O ::�:• U 3 - w = a EE 'HW 4"HW Y"CW 3/4"CW-4 HW SCULLERY LOUNGE 9 � T p'CW .. Yz"H ... O — "HW UOD ,i'HWC 1 - 1"CW � 1Y Hw � M 3/4„HW g w (y IFI "Hw 00 VERIFY) 4"G — p.EMS z„ON 00 ( CH TO LL F 1"Cw /4"HW UC n n n U m �w _ C w m M couNTER __ �- NEI (� O zM � wad G J a3M 8 7 LU L 0 0 o Q Q w �Z Z O � rn�a Z Zz � 0 0 _ z 5 7 8 Q o "--o E LU c`nv m W W 0 tI z W TE: 11/15/2023 SHEET TITLE: LEVEL SUPPLY PLAN LEVEL 1 SUPPLY PLAN ( 11 SCALE:1/4"=V-0" J SHEET NO. P3. 1 SHEET NOTES: 1. Provide expansion loops for all water piping per the manufacturer's instructions.See Detail 2/P6.0. 2. Provide trap primers for all floor drains per 2018 UPC 1007.1. ROOF See Detail 5/P6.0. 1"HW(3.38 FU) O Z 1yeCW(8.38 FU) 3. Provide MV-1 thermostatic mixing valves and set to 120°F in EL 2 1Ya"CW(9.5 FU) all public lavatories and kitchen handwashing sinks.See I W 1-CW(3.75 FU) 2"CWFU) N 1"CW(1.75 FU) 1"CW(4.5 FU) 1Ya"CW(6.5 FU) 1Ya"CW(7.25 FU) 1Ya'"CW(10.63 FU)1Y2"CW(13.63 FU) 2"CW(20.88 FU) 2"CW(25 FU) 2"CW(30.25 FU) Detail 7/P6.0. o - - -f'CW(2 FU) 3%"CW(1.13 FU� - - - - - - W(7.25 FU) - - 1 CW(5.75 FU) _ 1Ya"CW(9.38 FU) 1 FLAG NOTES: F1"HW(2.25 FU) 1'HW(4.5 FU) - - LL %a'"HW(0.75 FU) 3%a"HW(1.5 FU) � 1"HW(5.63 FU 1Y<"HW 7.88 FU) T3/a_HW(1_5 FU) _ __ 1. EXISYIng Z"CW line O__ _ -__--__ -__ 3 Y2_Hwc - HWCP-1 �rYz'Hwc� 2. Provide RPBP-1 on CW line to dishwasher. 3. Provide RPBP-2 on CW line to water filter system. z > j %"CW(1 FU)) LL LL LL LL 1"cw(3 Fu) 7 Y2"Hwc 4. Provide RPBP-3 on CW line to water filter system. N LL N LL LL M �2 m 3 0 0 o o 5. Provide RPBP-4 on CW line to water filter system. oFo❑❑❑�o V JA /,0OQ > op..... S z 1n 'x U x O evaas o b❑ N tV U P ❑ sn WATER WATERLIMP FILTER SINK RINSER FILTER HAND FILTER COMBI HAND 1-COMP 3-COMP 3-COMP DISH LAV LAV 0000Ospp�p `,j SYSTEM SYSTEM U SINK SYSTEM OVEN SINK SINK SINK SINK WASHER 11�15�2 LL � WH-1 Mo / 5 U 3%'CW(1 FU) / Yz"CW SINK WC t FLOOR 1 -T- T __w TP-1 TP-1 - 1"CW(2FU) RoBRSON ENGINEEING,INC i mrHnvew,s 1-2 LYNNWO0OWA96036 20636b33E3�n FEI PFOhQ`9C=" AD CONT UNDERSLAB O O 0 Y � SUPPLY DIAGRAM Z Y o U � w = a � O U Q a"v(saFu) ROOF SHEET NOTES: 2"V(14 FU) 3"V(84 FU) 2"V(7 FU) 2"V(13 FU) 3"V(79 FU) 3"V 30 FU 2"V(14 FU) 1. Waste&Vent Sizing:waste&vent piping sized per 2018 -- 3"V(73 FU) ( ) 2"V(21 Fu) 2"V(15 FU) UPC Table 703.2.Piping 4"and larger shall be sloped at r 2"V(5 FU) ----J__ 2"v�2zFuj------ - ----i- 3' ------------------------------------� per foot with approval ofAHJ.Piping smaller than 4"shall be ---- I I I V(79 FU) 1 "1Y2V(a FU) sloped at/a per foot: T-- T ----- T -- - -------T-------� I I I I 1 3"V(28 FU) I I I I I IL I L--- - ------ PIPE SIZE VERT. HORIZ. VENT L----_I-----1 1Y2"V(1FU) - ____I________I____I____I____I____I________I________I________ , I 1 �� 1Yz'v(1 Fu) I --I--------------------I----1----I--------I--------I--------1 I I 1/z 2 FU 1 FU 8 FU w N ----I____I--------I---J I I I I I 1 I I 2" 16 FU 8 FU 24DFU N -------------------I-----1--------1 I 1 1 I I I I I I ll co I �--------I---------------__I____I________I_______-I---J 3" 48 FU 35 FU 84 FU 4" 256 FU 172 FU 256 FU Q a Q o I I I I I I I LL I SI 6" 1,380 FU 576 FU 1,380 FU U 3 w I 1/2w(1 Fu) I 1 I I I SI LL 1 I I 8" 3,600 FU 2,112 FU 3,600 FU c N m"I �y I LLI LLI LLI �I �I >1 ?I >1 I I LL LL LL �I �I �I �I � a1 lVI 06 O W�L LL M 1 LLI >I I I I I I 2. Provide floor and wall cleanouts as required b code. a 3 I _ 1 4 Y HAND HAND v > > m a I �I I I I F o SINK SINK I ? I I I I I I wi 0 0 N 1 I I I I j I I 3. Provide trap primers for all floor drains per 2018 UPC 1007.1. Q o Z z 1 I I I I I I See Detail 5/P6.0. C m 1 I I I I I I '^ EL SINK I I I I I MopW FLOOR 1 ^ V7 1 3"FS-1 1 3"FS-1 1 2"FD-1 1 3"FS-1 1 3"FS-1 1 3"FS-1 1 2"FDA I 3"FS-1 FLAG NOTES: Z Z z 1 L L L I I I L 1 LL LL L I L L L L 00 1. Existing 4"V to roof. O 9) 1 S 2. Existing 4"SS to existing P.O.C. Vl Z 1 S S LL N S Q O ~/� 1 � �3 D3 LL3 _ LO IM W TV 43 FU soU soU c0 `-C7 �O -t7 LL LL w N W 2"SS(2 FU) <yt.�3"GW(8 FU) a a N W Z GI-1 4"GWG43 FU) 4"GW 40 FU) 3"GW 34 FU 3"GW 28 FU)�3"GWG�y W GW yy W 4"SS(45 FU) ( ) (20 FU) 3"GW4 FU) 3"GW(8 FU) 3"GW FU) 2 4"SS(55 FU) 1SS(43 FU) TE: 11/15/2023 3"SS(10 FU) 3"SS(6 FU) 3"SS(5 FU) SHEET TITLE: WASTE&SUPPLY DIAGRAMS UNDERSLAB SHEET NO. WASTE DIAGRAM P4.0 CONDENSATE DRAIN THROUGH-SLAB LAVATORY OR SINK PENETRATION SLEEVE OR WRAP F O_ PIPING TO PROTECT AGAINST BREAKAGE a CONCRETE FLOOR PER CODE HOT(i4p N w OR WALL TEE WITH SLIP JOIN ° °BY MECHANICAL CONTRACTOR COLD o FIXT.TAIL PIECE P-TRAP O Z WASTE THERMOSTATIC MIXING VALVE MAXIMUM ALLOWABLE PIPE LENGTH TO COMPLY WITH ASSE 1017 WALL BETWEEN FIXTURE AND HOT WATER PER WSEC TABLE C404.3.1 OOOOao ACO000Q, 0 02 ��eP`x^sy�: 0 °o p sn Eo CONDENSATE DRAIN TERMINATION PIPE SLAB PENETRATION A THERMOSTATIC MIXING VALVE 0D❑ °o�ssi SCALE:NONE V SCALE:NONE V SCALE:NONE • O 1"/�J CONNECT ABOVE CENTERLINE OF MAIN R O B I S O`'V■ 112" ENGINEERING,INC ,ew,amHavew,so—2 UNION WITHIN 12" Lvrvrvw000,wassoes BALL VALVE 20636b33E3n WATER TEST PORT MUST BE A MINIMUM DISTANCE OF REGULATOR pn a T 1rrEeorrosc_sreA PIPING—, OF 10X THE PIPE DIAMETER DOWNSTREAM MOUNT TRAP PRIMER OF THE REGULATOR GAS SUPPLY VALVE 12"FOR EVERY INSULATE PIPING TEST PORT TEST PORT Z z Q AS SHOWN IN SPECS 20'OF FOR LINE � O O BALL VALVE ABOVE Y 13 CEILING-SEE PLANS PPP MODEL PR-500 — FOR LOCATION. TRAP PRIMER VALVE o Z 0 1/2"GRAVITY TRAP O PROVIDE 8"x 8" PRIMER LINE CI Q v, w a ACCESS PANEL O U WHEN IN GYP. FLOOR DRAIN BOARD CEILING 6"MAX. L TO APPLIANCE I I ..... 3 SHUTOFF VALVES CEILING I I SLOPE TRAP ( ( J r PRIMER LINE P-TRAP SEDIMENTTRAP (") LU CV TYPICAL VALVE LOCATION FLOOR DRAIN AND TRAP PRIMER ^r� GAS PRESSURE REGULATOR IL a SCALE:NONE 6 SCALE:NONE V SCALE:NONE U3 oZf ° Wo m WALL "OFFSET'CONFIGURATION TERMINATE SLEEVE FLUSH WITH PIPE SLEEVE OF SIZE TO J x d PROVIDE STANDOFF FINISHED WALL SURFACE PASS PIPE AND INSULATION — MOUNTED TO WALL , (IF APPLICABLE)WITH MIN d" W i p o b x"L" ANNULAR SPACE Q Q �Z DRAIN 45° 777- CUT END D_ °' a HANGER OR GUIDE PIPE AND INSULATION f V FLOOR SINK jx"L" (IFAPPLICABLE) ` "JI Z REFER TO SPECIFICATIONS HANGER OR GUIDE CENTERED IN SLEEVE FINISHED ESCUTCHEON PLATE Z 1"MINIMUM PIPE AIR GAP FLUSH AGAINST WALL AND /\ FIRESTOP SLEEVE AT FLOOR FIRE-RATED WALLS OF SIZE TO COMPLETELY {rlr///f\ }x"L" COVER OPENING O Z CONCEALED PIPING PIPING EXPOSED TO VIEW a a.-. a INTERIOR WALLS 0 ~~ �' •_a • a a "LOOP"CONFIGURATION "CORNER"CONFIGURATION GALV STEEL PIPE SLEEVE COLLLA FOR CONCRET AND E LC140 W RESTRAINT OF SIZE TO PASS PIPE WALLS O Z S AND INSULATION WITH SEAL ENDS OF SLEEVE WITH U U' MIN d"ANNULAR SPACE w —� �—EXPANDING FOAM WEATHER- Z TIGHT SEALANT w LONG RUN OF PIPE "L" sx s x"L"MIN,TYP. PIPE AND INSULATION TE: 11/15/2023 (IF APPLICABLE) 'P'TRAP CENTERED IN SLEEVE sx"L" HANGERORGUIDE SHEET TITLE: COAT EXTERIOR SURFACES DETAILS HANGER OR GUIDE OUTDOOR INDOOR OF SLEEVE WITH COAL TAR EXTERIOR CONCRETE WALLS INDIRECT DRAIN TO FLOOR SINK 3 EXPANSION LOOP CONFIGURATIONS 2 PIPE SLEEVES THROUGH WALLS SHEET No. SCALE:NONE SCALE:NONE SCALE:NONE P6.0 Z N O F a0 D > N W w K O Z °pppopp°O °O J A °o NOT USED $ NOT USED 7 NOT USED 6 °OO°o op 15 2g SCAT F.NO- SLHLE:NONE S—E:NONE RoBiSON ENGINEERING,INC isADi amDAvew,wrt LYNNWOOD,WA96036 20636b33E3n FEI PFOJEC�N0.:962L29 0 0 0 0 Y � !J Z U U � w = a O U Q M LU N NOT USED ^r� NOT USED NOT USED ( LL- 00 S—E:NONE V S—E:NONE SLILLE:NONE V < 01 U 3 "6 O ?0 WATER HEATER VENT j¢ J ¢3M C =d10 "CLEANOUT"TO BE CAST 0 LLI i O 0 o 6"THICK BY 18" IN COVER CAST IRON CLEANOUT Q Q v Z SQUARE CONCRETE WITH COVER FOR ¢ Q o Z O PAD CAST IRON CLEANOUT MAY EXTEND AS APPLICABLE DUTY �3 rn _ -�a APPLICABLE DUTY WASTE OR VENT V FINISHED ��I V GRADE OR PAVING WALL FLOOR Z Q / ZI WITH COVER FOR PRESSURE&TEMP.RELIEF VALVE ll E O�� �jj�� (ROUTE TO NEAREST INDIRECT DRAIN) O � I-III-I I Imo-III-III- (' CHROME WALL COVER SHUTOFF VALVE JER �_ O Lo Z_AND SCREW AT FINISH CAST IRON EXTENSION- Q � �yAREAS ONLY SAME AS DRAIN SIZE MCAST IRON LONG SWEEP CAST IRON LONG SWEEP UP TO 4"DIAMETER ui CVitW 1/4BENDOR CAST IRON PLUGGED TEE 114 BEND OR CAST IRON W COMB.Y&1/8 BEND. WITH CLEANOUTCOMB.Y&118 BEND. O Z (USE REDUCING TYPE FLOOR (USE REDUCING TYPE FOR SIZE CHANGES) FOR SIZE CHANGES) DOMESTIC HOT WAT W DOMESTIC RECIRC RETURN�� R COLD WATER S- \ -�- TE: 11/15/2023 ILDING WASTE BUILDING WASTE DIRECTION OF FLOW OR DRAIN OR DRAIN CHECK VALVE EXTERIOR CLEANOUT TO GRADE(COTG) INTERIOR WALL CLEANOUT(WCO) INTERIOR FLOOR CLEANOUT(FCO) SHEET TITLE: (LIGHT TRAFFIC AREA) INSTALLTHERMAL EXPANSION DETAILS TANK(ET-1) FLOOR CLEANOUTS 2 WALL-MOUNTED WATER HEATER SHEET NO. S—E:NONE S—E NONE P6. 1 � f I , Permit#: 5726 Permit Date: 12/01/23 Permit Type: COMMERCIAL ALTERATION Project Name: Edison Cafe Applicant Name: Grandview North LLC Applicant Address: PO Box 159 Applicant, City, State, Zip: Arlington, WA 98223 Contact: Scott Wammack/ Sum Phone: 3604357171 Email: gv@grandviewinc.net Scope of Work: Tenant improvement for a coffee shop Valuation: 150000.00 Square Feet: 2037 Number of Stories: 1 Construction Type: VA Occupancy Group: A-2;Assembly ID Code: Permit Issued: Permit Expires: Form Permit Type: COMMERCIAL ALTERATION Status: IN PROCESS Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00847300001300 20501 OLYMPIC PL NE AFN 200507120732 GRANDVIEW 140 MIXED-USE NORTH LLC Contractors Contractor Primary Contact Phone Address Contractor Type License License# GRANDVIEW NORTH SCOTT 360-435-7171 PO BOX 159 CONSTRUCTION COA 601 858 917 LLC WAMMACK CONTRACTOR GRANDVIEW NORTH SCOTT CONSTRUCTION Labor& GRANDNL013KP LLC WAMMACK 360-435-7171 PO BOX 159 CONTRACTOR Industries Fees Fee Description Notes Amount Building Plan Review Table 4-2 $1,246.86 Total $1,246.86 Notes Date Note Created By: 12/04/2023 Need to verify suite number and update address in iWorQ Kristin Foster From: Summer Stemick To: Hannah Hardwick Subject: RE: BLD5726-Expiration Notice Date: Friday,February 21,2025 12:10:29 PM Attachments: image001.ona This message is from an External Sender This message came from outside the City of Arlington Hi Hannah, Can we please request another extension for this permit due to material delays and rescheduling of the subcontractors. Thanks, Summer Stemick Phone: (360) 435-7171 Gr dview PO Box 159 Arlington,WA 98223 From: Hannah Hardwick<hhardwick@arlingtonwa.gov> Sent:Tuesday,January 28, 2025 3:49 PM To: Summer Stemick<summer@grandviewinc.net>; Scott Wammack<gv@grandviewinc.net> Subject: BLD5726 - Expiration Notice Hello, This email is to inform you of the upcoming expiration date for permit 5726.This permit will expire on 03/17/2025. Please ensure that an inspection has been requested and approved prior to the expiration date. If you are not ready an inspection prior to the expiration date, please reply requesting an extension.The request needs to state cause for the extension and requires approval by the Building Official once received.Additional fees may be required upon extension approval. Please use the link below to view and request an inspection.You can also call in an inspection at 360-403-3417. Permits-Arlington (iworq.net) Sincerely, I OHannah Hardwick Arlington Community&Economic Development,Permit Technician I 18204 59th Ave NE,Arlington,WA 98223 O:360.403.3549 hhardwickCa'Oarlingtonwa.gov I www.arlingtonwa.gov Note: Emails and attachments sent to and from the City of Arlington are public records and may be subject to disclosure pursuant to the Public Records Act. ' CITY OF ARLINGTON • 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 20501 OLYMPIC PL NE,SUITE 102 Permit#: 5726 PERMIT EXPIRES 180 DAYS AFTER Parcel#: 00847300001300 DATE OF ISSUANCE. Scope of Work:Tenant improvement for a coffee shop Valuation: 150000.00 OWNER APPLICANT CONTRACTOR GRANDVIEW NORTH LLC Grandview North LLC GRANDVIEW NORTH LLC PO BOX 159 PO Box 159 PO BOX 159 ARLINGTON,WA 98223 Arlington,WA 98223 ARLINGTON,WA 98223 3604357171 360-435-7171 LIC:601 858 917 EXP:05/31/2024 LIC:GRANDNLO13KP EXP:07/14/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR A&D Mechanical Absolute Plumbing 9726 Waterworks Rd PO Box 1455 Marysville,WA 98271 Mount Vernon,WA 98273 LIC#:DMECHDM902CD EXP: 4/25/2024 LIC#:ABSOLP*799MB EXP:7/12/2024 JOB DESCRIPTION PERMIT TYPE: COMMERCIAL ALTERATION CODE YEAR: 2018 STORIES: 1 CONST.TYPE: VA DWELLING UNITS: 0 OCC GROUP: A-2;Assembly BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. cr� 03/06/2024 v"' Applicant Signature Date Building Official Date CONDITIONS Cross connection may be required.A discharge agreement is required with the Public Works Department for sanitary sewer. Contact the Public Works Department at 360-403-3526.Adhere to the approved plans.Approved job copy shall be onsite for inspections.Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 03/08/2024 Building Plan Review $1,246.86 03/08/2024 Credit Card Service $37.41 03/08/2024 Processing/Technology $25.00 03/08/2024 State Surcharge-Commercial $25.00 03/08/2024 Building Permit $1,918.24 Total Due: $3,252.51 Total Payment: $3,252.51 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Pen-nit Center:360-403-3551 BUILDING PERMIT 20501 OLYMPIC PL NE,SUITE 102 Permit#:5726 Parcel#:00847300001300 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:Tenant improvement for a coffee shop Valuation: 150000.00 OWNER APPLICANT CONTRACTOR GRANDVIEW NORTH LLC Grandview North LLC GRANDVIEW NORTH LLC PO BOX 159 PO Box 159 PO BOX 159 ARLINGTON,WA 98223 Arlington,WA 98223 ARLINGTON,WA 98223 3604357171 360-435-7171 LIC:601 858 917 EXP:05/31/2024 LIC:GRANDNL013KP EXP:07/14/2024 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR A&D Mechanical Absolute Plumbing 9726 Waterworks Rd PO Box 1455 Marysville,WA 98271 Mount Vernon,WA 98273 LIC#:DMECHDM902CD EXP: 4/25/2024 LIC#:ABSOLP*799MB EXP:7/12/2024 JOB DESCRIPTION PERMIT TYPE: COMMERCIAL ALTERATION CODE YEAR: 2018 STORIES: 1 CONST.TYPE: VA DWELLING UNITS: 0 OCC GROUP: A-2;Assembly BUILDINGS: I OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a stricture where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBCI 10/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 3 Ian I�� 03/06/2024 Applicant Signature / Date Building Official Date CONDITIONS Cross connection may be required.A discharge agreement is required with the Public Works Department for sanitary sewer. Contact the Public Works Department at 360-403-3526. Adhere to the approved plans. Approved job copy shall be onsite for nlspections. Call for inspections. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding envirom-nent or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 03/21/2024 Building Plan Review $1,246.86 03/21/2024 Credit Card Service $37.41 03/21/2024 ProcessinglTechnology $25.00 03/21/2024 State Surcharge-Commercial $25.00 03/21/2024 Building Permit $1,918.24 Total Due: $3,252.51 Total Payment: $3,252.51 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail From: Summer Stemick To: Kristin Foster Subject: RE:City of Arlington Permit Expiration-BLD5726 Date: Monday,August 19,2024 4:53:33 PM Attachments: imacae003.i)na This message is from an External Sender This message came from outside the City of Arlington We are going to need an extension on this permit due to material delays and rescheduling of the subcontractors. Thanks Summer Stemick Phone: (360) 435-7171 / f 9 l' Gra,q' dview_bj PO Box 159 Arlington,WA 98223 From: Kristin Foster<kfoster@arlingtonwa.gov> Sent:Thursday, August 8, 2024 1:54 PM To: Summer Stemick<summer@grandviewinc.net> Subject: RE: City of Arlington Permit Expiration - BLD5726 Hello, Can you please provide a brief summary of the reason for the extension request. I also sent one for the restaurant TI permit. Can you respond to that email as well. Thanks! Kristin Foster Permit Technician II Community and Economic Development 18204 59th Ave NE,Arlington,WA 98223 P.(360)403-3545 E.kfosterc@arlingtonwa.gov From: Summer Stemick<summer(@grandviewinc.net> Sent: Wednesday, August 7, 2024 12:49 PM To: Kristin Foster<kfoster(@arlingtonwa.gov> Subject: RE: City of Arlington Permit Expiration - BLD5726 This message is from an External Sender This message came from outside the City of Arlington We are going to need an extension on the permit. Thanks, Summer Stemick Phone: (360) 435-7171 Grfc-i ,qldNiew PO Box 159 Arlington,WA 98223 From: Kristin Foster<kfoster(@arlingtonwa.gov> Sent: Wednesday, August 7, 2024 10:49 AM To: Scott Wammack<gv(@grandviewinc.net>; Summer Stemick<summer(@grandviewinc.net> Subject: City of Arlington Permit Expiration - BLD5726 Hello, This email is a courtesy to inform you of the upcoming expiration date for permit BLD-5726 for the Edison Cafe TI. This permit will expire on September 17. Please ensure that an inspection has been requested and approved prior to the expiration date. If you are not ready an inspection prior to the expiration date, please reply requesting an extension.The request needs to state cause for the extension and requires approval by the Building Official once received. Additional fees may be required upon extension approval. Please use the link below to view and request an inspection. You can also call in an inspection at 360-403-3417. Permits-Arlington (iworq.net) Kristin Foster Permit Technician II Community and Economic Development 18204 59th Ave NE,Arlington,WA 98223 P.(360)403-3545 E.kfoster(@arlingtonwa.gov From: Summer Stemick To: Hannah Hardwick Subject: RE: BLD5726-Expiration Notice Date: Monday,August 11,2025 2:43:30 PM Attachments: image005.pno imaae006.Dna image007.png This message is from an External Sender This message came from outside the City of Arlington Hi Hannah, Can we please request another extension for this permit due to material delays and rescheduling of the subcontractors. Thanks, Summer Stemick Phone: (360) 435-7171 Grandview PO Box 159 Arlington,WA 98223 From: Hannah Hardwick<hhardwick@arlingtonwa.gov> Sent: Friday, July 25, 2025 2:22 PM To: Summer Stemick<summer@grandviewinc.net> Subject: BLD5726- Expiration Notice Hello, This email is to inform you of the upcoming expiration date for permit 5726.This permit will expire on 9/16/2025. Please ensure that an inspection has been requested and approved prior to the expiration date. If you are not ready an inspection prior to the expiration date, please reply requesting an extension.The request needs to state cause for the extension and requires approval by the Building Official once received.Additional fees may be required upon extension approval. Please use the link below to view and request an inspection.You can also call in an inspection at 360-403-3417. Permits -Arlington (iworq.net) Sincerely, I Hannah Hardwick Community&Economic Development Fire Permit Technician 11 18204 59th Ave NE,Arlington,WA 98223 O:360.403.3549 hhardwick(@arlinetonwa.goy I www.arlinetonwa.eov Note: Emails and attachments sent to and from the City of Arlington are public records and may be subject to disclosure pursuant to the Public Records Act. Permit#: 5726 Permit Date: 12/01/23 Permit Type: COMMERCIAL ALTERATION Project Name: Edison Cafe Applicant Name: Grandview North LLC Applicant Address: PO Box 159 Applicant, City, State, Zip: Arlington,WA 98223 Contact: Scott Wammack/ Sum Phone: 3604357171 Email: gv@grandviewinc.net Scope of Work: Tenant improvement for a coffee shop Valuation: 150000.00 Square Feet: 2037 Number of Stories: 1 Construction Type: VA Occupancy Group: A-2;Assembly ID Code: Permit Issued: 03/21/2024 Permit Expires: 03/16/2026 Form Permit Type: COMMERCIAL ALTERATION Status: ISSUED Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00847300001300 20501 OLYMPIC PL NE, AFN 200507120732 GRANDVIEW 140 MIXED-USE SUITE 102 NORTH LLC Contractors Contractor Primary Contact Phone Address Contractor Type License License# GRANDVIEW NORTH SCOTT 360-435-7171 PO BOX 159 CONSTRUCTION COA 601 858 917 LLC WAMMACK CONTRACTOR GRANDVIEW NORTH SCOTT 360-435-7171 PO BOX 159 CONSTRUCTION Labor& GRANDNLO13KP LLC WAMMACK CONTRACTOR Industries Plan Reviews Date Review Type Description Assigned To Review Status 12/08/2023 COMMERCIAL AIRPORT No Comment ALTERATION Received O1/05/2024 COMMERCIAL BUILDING Approved ALTERATION 12/08/2023 COMMERCIAL Please verify suite number PLANNING Pending Information ALTERATION 12/08/2023 COMMERCIAL No comments,LT&KS PW-ADMIN-GIS Approved ALTERATION 12/08/2023 COMMERCIAL A discharge agreement is required.Class 2.SB PW-SEW-REV Approved with ALTERATION Conditions COMMERCIAL Cross connection may be required after plumbing review. Approved with 12/08/2023 ALTERATION Gus PW-WAT-REV Conditions 03/06/2024 PERMIT TECHNICIAN Kristin Foster In Review 08/20/2024 PERMIT EXTENSION BUILDING Approved REQUEST 02/24/2025 PERMIT EXTENSION BUILDING Approved REQUEST 08/12/2025 PERMIT EXTENSION BUILDING Approved REQUEST Fees Fee Description Notes Amount Building Plan Review Table 4-2 $1,246.86 Credit Card Service $37.41 Processing/Technology $25.00 State Surcharge-Commercial Commercial Only $25.00 Building Permit Table 4-1 $1,918.24 Permit Extension $110.00 Permit Extension $110.00 Permit Extension $110.00 Total $3,582.51 Attached Letters Date Letter Description 03/06/2024 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 12/07/2023 XBP Conf: $1,246.86 160306090 12/07/2023 Summer Stemick 160306090 Kristin Foster $37.41 02/27/2024 XBP Con£ $1,968.24 166688437 08/23/2024 XBP Conf: $110.00 208227342 02/24/2025 XBP Con£ $110.00 224085400 08/29/2025 XBP Con£ $110.00 241564916 Outstanding Balance $0.00 Notes Date Note Created By: 03/02/2026 sent expiration notice Hannah Hardwick 02/02/2026 Expiration Notice sent LaNay Hendrick 07/25/2025 sent expiration notice Hannah Hardwick O1/28/2025 sent expiration notice Hannah Hardwick 08/28/2024 KO approved the permit extension.New expiration date is 3.17.2025 Kristin Foster 08/20/2024 Received a request for a permit extension. Kristin Foster 08/07/2024 Sent permit expiration notice. Kristin Foster O1/05/2024 Received appliance specification sheets as requested by KO. Kristin Foster 12/04/2023 Need to verify suite number and update address in iWorQ Kristin Foster Uploaded Files Date File Name 08/12/2025 27777210-20250812 BLD5726 Permit Extension Request.pdf 02/24/2025 24644809-20240224 BLD5726 Permit Extension Request.pdf 08/20/2024 22077457-20240819 BLD5726 PermitExtensionRequestEmail.pdf 03/06/2024 18837487-20240118 BLD5726 ApnrovedPlumbPlans.pdf 03/06/2024 18837488-20240118 BLD5726 ApprovedArchPlans.pdf 03/06/2024 18837485-20240118 BLD5726 ApprovedElectricalPlans.pdf 03/06/2024 18837486-20240118 BLD5726 AnprovedMechPlans.pdf 12/08/2023 17710476-20231201 BLD5726 Application.pdf