Loading...
HomeMy WebLinkAbout3319 176TH PL NE_BLD1001_2026 RESIDENTIAL MECHANICAL 01" "" PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:3319 176th PI NE Project Description: HVAC replacement: Ductwork, demo, furnace, AC, venting, (2) fans, and gas piping (3) outlets Owner: Donna Bosley Address: 3319 176th PI NE City: Arlington State Wa Zip Code: 98223 Phone. Serv-Pro #: 360-243-8313 Email:rightonheating@frontier.com Applicant: Contractor: Right On Heating -Jeanie Graves Address: PO 758 City: Lake Stevens StateWa Zip Code: 98258 Phone: 425-335-4207 Email. rightonheating@frontier.com CONTRACTOR INFORMATION Contractor Name:Right On Heating & Sheet Metal, Inc. Address: PO 758 City: Lake Stevens State:Wa Zip Code: 98258 License Number:RIGHTHM988CM Expiration: 02/14/2018 Phone 425-335-4207 Email.rightonheating@frontier.com STAFF USE ONLY Permit #: Accepted by: Date: RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #TG8SO40A08MP11 AFUE 80% [3 Heat Pump Model # AFUE HSPE [d AC Unit Model #TCHD18S41S3 SEER 13 [� Freestanding Stove Fire Place Insert Outdoor BBQ I� Gas Piping 0 Solid-Fuel Appliance Q Other Gas Piping Information Not Applicable: ❑ Pipe Material: Black Steel Pipe Size: 1" Distance From Meter to Furthest Appliance: 60' Total BTU's of all Appliances: 120K • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: L cv Date: 05/05/2016 Applicant Printed Name: Jeanie L Graves l hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. COMMERCIAL MECHANICAL , PRESSURE PIPING INFORMATION Department of Community& Economic Development City of Arlington •.18204 59th Ave NE•Arlington, WA 98223•Phone (360)403-3551 If gas piping will be installed this form Is required in addition to a Commercial Mechanical Permit Application Pipe Material: Inlet Pressure: Pressure Drop: _ Specific Gravity: _ Pressure Piping Schematic Show Pipe Size(s)and Length(s)from meter to all appliances. ❑ Scale or ❑ Not to Scale NOTE: any l l lntt?rior pressure regulators must be f trl Q C' e. indicated LJ a�� e NOTE: drip. . legs/sediment traps are required at all appliances unless integrated in the listed appliance I i 1Z/,/aM 1i1�� I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accordance with the laws, rules and regulation of the State of Washington. Appllcants Signature Date Print Applicants Name r CITY CIF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON,WA,98223 PHONE; (360)403-3551 . . - B�JILD�NG PERI4IIT �. Address:3319176th PI NE Permit#: 1001 Parcel 8:006213000093M Valuation:0,00 Nato:BOSLEY DONNA SUE Name:Right on Heating and Slut Metal Inc. Name:RIGHT ON HEATING Address:3319 176TH PL NE Addrtss:P.O.Box 758 Address:2213 13Ist Avenue NE City,State Zip:ARLINGTON,WA 98223 Cit},State Zip:Lake Stevens,WA 98258 City,State Zip:Lake Stevens,WA 98258 Phone: Phone:425.335-4207 Phonc:425.335-4207 MEPHANICAL CQNT RACTOR PLUMBING C IUiU"" Name:RIGHT'ON HEATING Name: Address:2213 131st Avenue NE Address: City,State,Zip:Lake Stevens,WA 98258 City,State,Zip: Phone; 425-335-4207 Phone; LIC#; EX.P: LIC#: EXP: JOB DESCRIPT)CON .PERMIT TYPE: Residential Mechanical CODE YEAR: 2012 STORIES: 1 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: 1 OCC LOAD: f PERMIT APPROVAL AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON'RELATING TO WORKMEN'S COMPENSATION INSURANCE?AND RCW 18.27, THIS APPLICATION IS NOT A PERMIT UNIT].SIGNED BY THE BUILDING OFFICIAL OR HISMER DEPUTY AND ALL FEES ARE PAID. I IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRCL.10, SALES TAX NOTICE:Sal tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form coded City of Arlington V0I. ow Signature Print Name Nate Released By to CONDITIONS Duct Testing is requited per the 2012 Washington State Energy Code RI O1.4.3.1,An Air Leakage test is required per the 2012 Washington State Energy Code R402.4.1.2,.Additional Requirements: 3" concrete pad with seismic bracing attached to pad;provide electrical disconnect; Lines shall be insulated-the use of adhesive tape is not permitted, THIS PERMIT AUTHORIZE ONLY THB WORK NOT Mi .THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY,ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REW MW SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 5/1 612 0 1 6 Furnace $25,00 5/1 612 0 1 6 Gas Outlets Base Fee 1 to 5 $10.00 5/16/2016 Heat Pump $25.00 5/16/2016 Mechanical Permit Base Fee $25.00 5116/2016 Vents $10.00 Total Due: S95.00 Total Payment: $0.00 Balance Due: S95.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following Information, Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon " CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:3319 176th PI NE Permit#:1001 Parcel#:00621300009300 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:BOSLEY DONNA SUE Name:Right on Heating and Sheet Metal Inc. Name:RIGHT ON HEATING Address:3319 176TH PL NE Address:P.O.Box 758 Address:2213 131st Avenue NE City,State Zip:ARLINGTON,WA 98223 City,State Zip:Lake Stevens,WA 98258 City,State Zip:Lake Stevens,WA 98258 Phone: Phone:425-335-4207 Phone:425-335-4207 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:RIGHT ON HEATING Name: Address:2213 131st Avenue NE Address: City,State,Zip:Lake Stevens,WA 98258 City,State,Zip: Phone: 425-335-4207 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2012 STORIES: 1 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRCI10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 5/7 Signature Print Name Date Released By I A lc CONDITIONS Duct Testing is required per the 2012 Washington State Energy Code RI O1.4.3.1,An Air Leakage test is required per the 2012 Washington State Energy Code R402.4.1.2.Additional Requirements: 3" concrete pad with seismic bracing attached to pad;provide electrical disconnect; Lines shall be insulated-the use of adhesive tape is not permitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 5/16/2016 Furnace $25 00 5/16/2016 Gas Outlets Base Fee 1 to 5 $10.00 5/16/2016 Heat Pump $25.00 5/16/2016 Mechanical Permit Base Fee $25.00 5/16/2016 Vents $10.00 Total Due: $95.00 Total Payment: $0.00 Balance Due: $95.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon 556454-YTG-E-0914 10- ® DESCRIPTION The 13 SEER Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be custom- i2YOR matched with one of UPG's complete line of evaporator sections, with each serving a specific function. Matching Air Handlers are available for upflow,downflow, or horizontal applications to pro- Technical Guide vide a complete system. Electric Heaters are available, if re- quired.Add-On coils are available for use with upflow,downflow, or horizontal furnaces and air handlers. SPLIT-SYSTEM AIR CONDITIONERS 13 SEER - R-410A- 1 PHASE FEATURES 1.5 THRU 5 NOMINAL TONS • Performance-Efficiency levels from 13.0 SEER/11.0 EER with a loose coil up to 16.0 SEER/14,0 EER(some models) MODEL : TCHD18 HRU 60 when coupled with an ECM indoor blower. • Small Footprint-Compact"slim-line"design allows for easy installation in tight spaces. Units can be stacked two-high with approved stacking kit, • QuietDriveTm System-The combination of a swept-wing fan, rigid base pan, isolated compressor compartment, and quiet scroll compressor reduce sound to as low as 70 dBA. • Low Operating Sound Levels-The swept-wing condenser fan in blow-through configuration provides for whisper-quiet operation by allowing air to flow smoothly and efficiently across the fan tips. • Quality Condenser Coils-The coil is constructed of alumi- num microchannel tubing and enhanced aluminum fins for compact size and increased efficiency. Environmentally Friendly Refrigerant-The next genera- tion refrigerant R-410A delivers environmentally friendly per- OUlC9IXAF.ALN�10 6pNLVApB2 formance with zero ozone depletion. GNausekeeping • ! Durable Finish-Heavy-gage steel cabinet and tubular base rails provide added support. Aesthetic-Powder paint"Champagne"color provides an at- AMERICAN tractive retail finish, p�'uALIETY ERED& Commercial Applications-The TCHD 3 Phase Series is al- so 900 ` S ® ASSEMBLED /zIN THE LISA so available in 2081230-3-60 and 460-3-60 voltages in the Certified Quality C US. 2 ,3,4, 8r 5 ton models. Management System • Other Features; Due to continuous product improvement,specifications are sub- — Factory supplied filter drier ject to change without notice. — High pressure switch, low pressure switch — Accumulator and crankcase heater in all sizes Visit us on the web at — Up to 200'line set out of the box www.upgnet,COM and www.york.com — Zero lot line-only 6"minimum clearance from structure Additional rating information can be found at Agency Listed-Safety certified by CSA to UL 1995/CSA www.ahridirectory.org 22.2. Performance certified to ANSI/AHRI Standard 210/240 in accordance with the Unitary Small Equipment certification WARRANTY SUMMARY program. Extended 10-year limited parts warranty. Standard 10-year[imited compressor warranty. Extended 10-year limited parts warranty requires online registration within 90 days of purchase for replacement or clos- ing for new home construction. 'Does not apply to R-22 models,3-Phase models,or Intemet sales, See Limited Warranty certificate in User's Information Manual for details. FOR DISTRIBUTION USE ONLY-NOT TO BE USED AT POINT OF RETAIL SALE 556454-YTG-E-0914 Physical and Electrical Data MODEL TCHD18 TCHD24 TCHD30 I TCHD36 TCHD48 TCHD60 S41S3 S41S4 S41S3 S41S3 S41S3 S41S3 Unit Supply Voltage 208-230V,1�,601-1z Normal Voltage Range 1 187 to 252 Minimum Circuit Ampacity 11.8 18.3 17.5 23.1 27.1 34.3 Max,Overcurrent Device Amps 2 20 30 30 40 45 60 Min.Overcurrent Device Amps 3 15 20 20 25 30 35 Type Scroll Scroll Scroll Scroll Scroll Scroll Compressor Rated Load Amps 9.0 13.5 12.8 17.3 20.5 26.3 Locked Rotor Amps 48,0 58.3 64.0 96.7 115.0 134.0 Crankcase Heater Yes Yes Yes Yes Yes Yes Factory External Discharge Muffler No No No No No No Factory External Check Valve No No No No No No HS Kit Required with TXV 4 No No No No No No Fan Diameter Inches 17.5 23 23 23 23 23 Rated HP 1/8 114 114 1/4 1/4 114 Rated Load Amps 0.6 1,5 1.5 1.5 1.5 1.5 Fan Motor Nominal RPM 840 850 850 850 850 850 Nominal CFM 1150 3200 3200 3200 3050 3050 Face Area Sq,F1, 5.76 11.96 11.96 11.96 13.96 13.96 Coil Rows Deep 1 1 1 1 1 1 Fins/Inch 23 23 23 23 23 23 Max.Length 200 200 200 200 200 200 Max.Lift 65 65 65 65 65 65 Refrigerant Lines Max.Drop 150 150 150 150 160 150 � Liquid Line Set OD(Field Installed) 318 3/8 3/8 3/8 3/8 318 Vapor Line Set OD(Field Installed) 3/4 3/4 3/4 314 7/8 7/8 Unit Charge(Lb s.-Oz.)5 2-10 4-1 4-0 4-8 5-5 5-6 Charge Per Foot,Oz. 0.62 0.62 0,62 0.62 0.67 0.67 Operating Weight Lbs. 130 195 195 215 240 250 1. Rated in accordance with AHRI Standard 110-2012,utilization range"A". 2. Dual element fuses or HACR circuit breaker.Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker.Minimum recommended overcurrent protection. 4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model. 5. When more than 50 feet of interconnecting tubing and more than 30 feet of vertical lift is used,consult the Application Data(part number 247077),For long-4ine ap- plications,interconnecting lines over 100 feet must be installed with liquid line solenoid, 6. The Unit Charge is correctfor the outdoor unit,smallest matched indoor unit.and 15 feet of refrigerant tubing,For tubing lengths other than 15 feet,add or subtract the amount of refrigerant,using the difference in actual lineset length(not equivalent length)multiplied by the per foot value. Dimensions Refrigerant - \ Unit (Inches) Connection Model Service Valve Size C A B C Liquid Vapor 18 25-1/4 17-1/2 37-1/4 24 37-1/4 20 45 3/4 A 30 37-1/4 20 45 3/8 36 37.1/4 20 45 48 43-1/4 20 45 7/8 60 43-1/4 20 45 All dimensions are in inches and are subject to change without notice. Overall height is from bottom of mounting feet to top of unit, Overall length and width include mounting feet and screw heads. �B 2 Johnson Controls Unitary Products 556454-YTG-E-0914 System Charge for Various Matched Systems Outdoor Unit TCHD18S41S3 TCHD24841S4 TCHD30S41S3 TCHD36S41S3 TCHD48S41S3 FTCHD60S41S3 Required TXV 1,2 4F1 4F1 4G1 4G1 4J1 4K1 Indoor Unit 3,4,6 Additional Charge,Oz AHE18B 4 — — — — — AHE24B 17 14 — — — — AHE30B 17 14 10 — — — AHE36C 24 20 16 12 — — AHE42D — 32 27 22 — — AHE48D — — — — 11 — AHE60D — — — — 16 13 AHR18B 4 — — — — — AHR24B -- 14 — — — — AHR30B — — 10 — — — AHR366 — — 16 12 — — AHR42C — — — 22 — AHR48D — — — — 11 — AHR60D — — — — 16 — AHV188 0 — — _ — AHV24B 13 9 — — — — AHV30B 14 9 0 — — — AHV36C 21 16 7 0 — — AHV42D — — 18 11 — — AHV48D — — — 10 0 — AHV60D — — — — 4 0 FC/MC/PC18 4 — — — — — FCIMC/PC24 4 0 — — — — FC/MClPC32 17 14 10 6 — — FC/MC/PC35 17 14 10 6 — — FCIMCIPC37 24 21 16 12 — — FC/MC/PC43 — 20 16 0 — — FClMC/PC48 — 32 27 22 0 — FC/MC/PC60 — — — — 10 .- FC/MC62 — — — — 16 0 FC64 — — — — 25 11 HD24 26 17 — — — — HD36 32 20 14 11 — — HD48 -- — — 33 24 — HD60 — — — — 30 22 UC18 5 — — — — — UC24 9 5 — — — — UC48 — 25 21 17 6 — UC60 - - I - - 11 Some of the combinations shown in the above System Charge table require Advanced Main Air Circulating Fan indoor product.For approved coil only matches,please see the"COOLING CAPACITY-Upflow,Downflow&Horizontal Furnaces and Coils"table. FOOTNOTES: 1. For applications requiring a TXV use S1-1TVM..*series kit. 2, A TXV klt must be used with these indoor units to obtain system performance. 3. Systems matched with furnaces or air handlers not equipped with blower-off delays may require blower Time Delay Kit S1-2FD06700224. 4. PC coils cannot be used in downflow or horizontal applications.FC coils cannot be used in horizontal appilcations. 5. Refer to Cooling Performance Data tables for actual system performance for specified system matches. PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the outdoor unit,the smallest matched indoor unit,and 15 feet of interconnecting line tubing. 2. Verify the TXV and additional charge required for specific matched indoor unit in the system using the above table. 3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specifed in Physical and Electrical Data Table. 4. For indoor matches requiring additional charge,the refrigerant needs to be weighed in for specific matched indoor unit and actual lineset length. 5. Permanently mark the unit nameplate with the total system charge,Total System Charge=Base Charge(as shipped)+charge adder for matched indoor unit +charge adder for actual Masai length. Johnson Controls Unitary Products 3 556454-YTG-E-0914 ACCESSORIES Start Assist Kit(S1-2SA067)-Provides increased starting tor- que for areas with low voltage.See Hard Start Kit Accessory In- Refer to Price Manual for specific model numbers. stallation Manual for Hard Start Kit part number for each model. Application Limits TXV Kits-51-1TVM series thermal expansion valves precisely Maximum Lineset Equivalent Length 200 Ft meter refrigerant for optimum performance over a wide range Outdoor Ambient Temperature Limits of conditions,See System Charge table for TXV part number Cooling Operation Maximum DB 115°FMinimum DB 50°F for each model. Low Ambient Pressure Switch Kit(S1-2LA06700424)-Al- Long Lineset Applications-For installations with more than lows the use of air conditioning at low outdoor ambient temper- 75'of equivalent lineset length, refer to the current version of atures down to+20°F(-7`C). For use with single-stage models the Piping Application Guide 247077-UAD-H-0209,available containing R-410A refrigerant only, in the Application Bulletins section on UPGnet. Thermostats-Compatible thermostat controls are available Off Cycle Timer Delay-Provides a 5-minute off cycle to pre- through accessory sourcing, For optimum performance and in- vent rapid recycling of the compressor. stallation, refer to the UPGNET"Low Voltage Wiring Diagram" document to select and apply controls. SOUND POWER LEVEL-TYPICAL OCTAVE BAND SPECTRUM(without tone adjustment) Model Octave Band Sound Power Level(db re.1-pM Number 63 125 250 Soo 1000 2000 4000 8000 dBA SQI - TCHD18841S3 71 71 76 65 62 57 52 48 70 19.0 TCHD24S41S4 73 78 69 67 65 60 57 58 70 19.1 TCHD30S41S3 73 78 69 67 65 60 57 58 70 19.1 TCHD36S41S3 74 77 68 67 66 61 58 58 71 19.1 TCHD48S4lS3 75 81 70 68 66 61 58 58 72 19.0 TCHD60S41S3 73 81 71 67 66 61 58 59 72 19.2 Rated in accordance wish ARI Standard 270 MOUNTING HOLE GRAPHIC Imo—28.06 20.38 7.50 I 18.73 16.23 EU SMALL CABINET LARGE CABINET Johnson Controls Unitary Products 23 556454-YTG-E-0914 TYPICAL INSTALLATION THERMOSTAT WEATHERPROOF 8 DISCONNECT SWITCH NEC CLASS 1 WIRING 6"CLEARANCE AROUND PERIMETER � TO FURNACE OR K AIR HANDLER TERMINAL BLOCK > N-C CLASS 2 WIRING AIRFLOW TO INDOOR UNIT DIRECTION NOTES: ALL OUTDOOR WIRING MUST BE WEATHERPROOF. CAN BE STACKED TWO-HIGH WITH APPROVED STACKING KIT. MINIMUM 18'CLEARANCE SEAL OPENING(S)WITH FOR CONTROL ACCESS PANELS PERMAGUM OR EOUIVANT TYPICAL FIELD WIRING ALL FIELD WRING TO BE IN ACCORDANCE WITH ELECTRIC CODE(NEC)AND/OR LOCAL CODES PCWFR WIRING - - - POWER WIRING 2081230-1-60 P4 VOLT CONTROL WIRING - - - - CONTROL WIRING MINIMUM 18 GA.WIRE FACTORY WIRING I (NEC CLASS 2) FURNACE OR AIR HANDLER TERMINAL BLOCK Y R O W *TERMINAL W IS ONLY 001 CONTACTOR I I I ( I REQUIRED ON SYSTEMS TERMINALS I I I I I I WITH HEAT. LUG COIL - -I OOOOW * i CONDENSING UNIT ROOM THERMOSTAT ALL OUTDOOR WIRING MUST BE WPA1'HERPROOR. USE COPPER CONDUCTORS ONLY. 24 Johnson Controls Unitary Products 556454-YTG-E-0914 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCHD18S41S3 INDOOR COIL MODEL NO. FCIMCIPC24 AIR TEMP.ENTER- IDCFM 450 600 750 ING OUTDOOR UNIT ID DB('F) 80 80 75 1 80 80 80 80 75 80 80 80 80 1 75 80 1 80 (*F) ID WB('F) 57 62 fit 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 17.3 18.2 18.6 19.7 1 21,5 18.9 19.0 19.2 20.6 22.5 20.4 19.7 19.8 21.5 23.4 65 S.C. 16.6 14.5 12,6 12.2 9.9 18.0 16.9 14.3 14.2 10.7 19.4 19.3 15,9 16,2 11.6 KW 1.07 1.08 1.09 1.08 1.07 1.07 1.07 1,09 1.07 1,07 1.07 1.07 1.08 1.07 1.08 T.C. 16.2 17.3 17.8 18.9 20.7 17.8 18.2 18.4 19.7 21.5 19.4 19,1 19.0 20.5 22.3 75 S.C. 15.7 13.9 12.2 11.8 9.6 17.2 16.4 13.9 13.7 10.5 18.7 18.8 15.6 16.6 11.4 KW 1.28 1.28 1.28 1.27 1.25 1.27 1.27 1.27 1.26 1.25 1.26 1.26 1.27 1.26 1,26 T.C. 15.1 16,5 16.9 18.1 20.0 16.7 17.5 17.6 18.9 20.5 18.3 18.5 18.2 19.6 21.1 85 S.C. 14.8 13,3 11,8 11.4 9.3 16.4 15.8 13.5 13.1 10.2 18.0 18.4 15.3 14,9 11.2 KW 1,48 1.48 1.47 1.46 1.44 1.46 1.46 1.46 1.45 1.43 1.44 1.44 1.46 1A4 1.43 T.C. 14.0 15.7 16.1 17.3 19.2 15.6 16.8 16.8 a 1,8.0 19.6 17.3 18,0 17A 18.7 19.9 95 S.C. 14.0 12.7 11.3 11.0 8.9 15,6 15.3 13.1 :12 6 10.0 17.3 17.9 14.9 14.2 11,0 KW 1.68 1.68 1.66 1.64 1.62 1.65 1.66 1.65 'fk4'r 1.61 1.63 1.63 1.64 1.63 1.61 T.C. 13.4 14,5 14.9 16.0 18.1 14.8 15.6 15.6 16.8 18,5 16.3 16.7 16,2 17.6 18.9 105 S.C. 13.3 12.2 10.7 10A 8.5 14,8 14.5 12.4 12.0 9.5 16.3 16.7 141 13.7 10.5 KW 2.16 2,12 2.11 2,12 1.93 2.08 2.06 2.07 2.04 1.92 1.99 1.99 2.02 1.95 1.91 T.C. 12.7 13.5 13.7 14.7 16.9 14.0 14.5 14.4 15.6 17.4 15,3 16.6 15.1 16.5 17.9 115 S.C. 12,6 11.6 10.0 9.8 8.0 14.0 13,6 11.6 11.5 9.0 15.3 15.6 13.2 13.2 10.0 KW 2.63 2.54 2.55 2.58 2,23 2.48 2.44 2.47 2.42 2.21 2.34 2,34 2.40 2.27 2.20 T.C. 12.1 12A 12.6 13.4 15.8 13.2 13.4 13.2 14.4 16.3 14.3 14.4 13.9 16.6 16.8 126 S.C. 12.0 11.1 9.4 9,2 7.6 13.1 12.8 10.9 10.9 8.5 14.3 14.4 12.4 12.7 9.5 KW 3.10 2,97 3.00 3.04 2.53 2.89 2.83 2.88 2.81 2.51 2,69 2.68 2.77 2.58 2.49 NOTE:ALL CAPACITIES INCLUDE INDOOR FAN HEAT.KW VALUES ARE FOR THE SYSTEM(OUTDOOR+INDOOR). Blue shaded cells are AHRI conditions. Green shaded cells are ACCA(TVA)conditions. Multipliers for determining the performance with other indoor sections. NOTE:For dry bulb temperatures different than those listed(between 73-87 IF),sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature. Air Handlers Coils T.C. S.C. KW Furnaces Coils T.C. S.C. KW - FC/MC/PC24 1.00 1.00 1.00 T'(8,L)C*Al2 FCIMC/PC18A 1.01 1.10 0.92 - FCIMC/PC32 1.01 1.00 1.00 T'(8,L)C'Al2 FCIMC/PC24A 1.03 1.06 0.93 - FC/MC/PC35 1.01 1.00 1.00 T'(8,L)C*Al2 FCIMC/PC32A 1.02 1.04 0.92 - FC/MC/PC37 1.02 1,01 1.00 T'(8,L)C'Al2 FC/MC/PC37A 1.04 1.07 0.93 - HD24 1.04 1,02 1.01 T'(8,L)C*Al2 HD24 1,06 1.10 0.93 - UC24 1.00 0.99 1.00 T''(B,L)C'Al2 HD36 1.03 1.02 0.92 AHE18B - 1.01 1.02 0.92 T'(8,L)C'Al2 UC18A 1.01 1.11 0.92 AHE24B 1.02 1.03 0,91 T'(8,L)C'Al2 UC24A 1.03 1.06 0.93 AHE30B 1.02 1.03 0.91 T'(8,L)C'B12 FC/MC/PC18B 0.99 1.09 0.91 AHE36C 1.08 1.16 0.93 T'(8,L)C'B12 FC/MC/PC24B 1,02 1.03 0.91 AHR18B - 0.99 1.02 0.99 T'(8,L)C'B12 FC/MC/PC35B 1,03 1.06 0.92 AHV18B 1.00 1.01 0.96 T'(8,L)C*B12 HD24 1.06 1.06 0.91 AHV24B - 1,01 1.02 0.95 T*(8,L)C*812 HD36 1.03 1.02 0.92 AHV306 1.02 1.10 0.96 T*(8,L)C*B12 UC18B 1.00 1.10 0.91 AHV36C 1.03 1.09 0.95 T'(B,L)C*B12 UC24B 1.02 1.04 0.90 MV12B FC/MC24B 1,02 1.02 0.93 T'(8,1-)C*C16 FC/MCIPC35C 1.03 1.06 0.91 MV12B FC/MC35B 1.02 1,04 0.93 T'(8,L)C'C16 HD36 1.03 1.02 0.91 MX12BN21 FC/MC18B 1.00 1.01 0.96 T*(8,L)V'Al2 FC/MCIPC24A 1,03 1.06 0.93 MX12BN21 FC/MC24B 1.02 1.03 0.94 T'(8,L)V*Al2 FCIMC/PC32A 1,02 1.04 0.92 MX12BN21 FC/MC35B 1.02 1.04 0,94 T*(8,L)V'Al2 FC/MC/PC37A 1,04 1.07 0.93 MX16CN21 FC/MC35C 1.01 1.02 1.03 T'(8,L)V*Al2 HD24 1.06 1A0 0.93 T'(8,L)V*Al2 HD36 1.03 1.02 0,92 T'(8,L)V*Al2 UC24A 1.03 1.06 0.93 T'(8,L)V*B12 FCIMC/PC24B 1.02 1.03 0.91 T'(8,L)V*B12 FCIMC/PC358 1.03 1,06 0.92 T*(8,L)V*B12 HD24 1,06 1.06 0.91 T'(8,L)V'B12 HD36 1.03 1.02 0.92 T*(8,L)V'B12 JUC24B 1.02 1.04 0,90 Johnson Controls Unitary Products 25 CITY OF ARLINGTON 238 N.OLYMPIC AVE -ARUNGTON, WA.98223 PHONE; (360)403-3551 BUILDING.PERMIT ..__; _..: --• ... . . Address:3319176th PI NE Permit f1:1001 Parcel 0:00621300009300 Valualion:0.00 OWNER APPLICANT _,M1kff RAC-0R Name:BOSLEY DONNA SUE Name:Right on Heating and Sheet Metal Inc. Name:RIGHT ON IW,,ATFNG Address:3319 176TH PL NE Address:P.O,Box 758 Address:2213 13 tst Avenue NE City,State Zip:ARLINGTON,WA 98223 City,State Zip:Lake Stevens,WA 98258 City,State Zip:Lake Stevens,WA 98258 Phone: Phone:425-335-4207 Phone:425.335-4207 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR i Name:RIGHT ON HEATING Name: Address:2213 131st Avenue NE Address: City,State,Zip:Lake Stevens,WA 98258 City,Slate,Zip: Phone: 425-335-4207 Phone; LIC 4; EXP: LIC St EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical COIIE YEAR: 2012 STORIES: 1 CONST,TYPE: DWELLING UNITS: OCCGROUP: BUILDINGS; ] OCC LOAD: PERMIT APPROVAL I.AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTFIORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF TIIE LABOR CODE;OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18,27, TIES APPfACATION IS NOT A PERMIT UNTIL SIGNED BY TIIE BUILDING OFFICIAL OR I IISMER DEPUTY AND ALL FEES ARE PAID. IT IS LNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. I.BCI10/IRCI I0. SALES TAN SNOTICC:Sal tax relating to construction and construction materials in[he City of Arlington must be reported on your sales tax return form coded City of Arlington Ol. i Signature Print Name Date Released By Dfitt CONDITIONS Duct Testing is required per the 2012 Washington State Energy Code R101.4.11,An Air Leakage testis required per the 2012 Washington State Energy Code R402,4.1.2, Additional Requirements: 3"concrete pad with seismic bracing attached to pad;provide electrical disconnect, Lines shall be insulated-the use of adhesive tape is not permitted, THIS PERMIT.AUTIIORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUESS,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES _ _ Date Description fee Amount 5/16/2016 Furnace $25,00 511612016 Gas Outlets Base Fee 1 to 5 $10.00 511612016 Heat Pump $25.00 5/16/2016 Mechanical Permit Base Fee $25.00 5/16/2016 Ve nts $10.00 Total Due: $95.00 Total Payment; f0.00 Balance Are: S95.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When eallinq for as Inspection please leave the following informatiost: Permit Number,Type of inspection being requested,and whether you prefer morning or afternoon ° CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMT Address:3319 176th PI NE Permit#:1001 Parcel#:00621300009300 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:BOSLEY DONNA SUE Name:Right on Heating and Sheet Metal Inc. Name:RIGHT ON HEATING Address:3319 176TH PL NE Address:P.O.Box 758 Address:2213 131st Avenue NE City,State Zip:ARLINGTON,WA 98223 City,State Zip:Lake Stevens,WA 98258 City,State Zip:Lake Stevens,WA 98258 Phone: Phone:425-335-4207 Phone:425-335-4207 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:RIGHT ON HEATING Name: Address:2213 131 st Avenue NE Address: City,State,Zip:Lake Stevens,WA 98258 City,State,Zip: Phone: 425-335-4207 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2012 STORIES: I CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 000 �d l7 Signature Print Name Date Released By Dhte CONDITIONS Duct Testing is required per the 2012 Washington State Energy Code R101.4.3.1, An Air Leakage test is required per the 2012 Washington State Energy Code R402.4.1.2.Additional Requirements: 3" concrete pad with seismic bracing attached to pad; provide electrical disconnect; Lines shall be insulated-the use of adhesive tape is not permitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 5/16/2016 Furnace $25.00 5/16/2016 Gas Outlets Base Fee 1 to 5 $10.00 5/16/2016 Heat Pump $25.00 5/16/2016 Mechanical Permit Base Fee $25.00 5/16/2016 Vents $10.00 Total Due: $95.00 Total Payment: $0.00 Balance Due: $95.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,'Type of Inspection being requested,and whether you prefer morning or afternoon �z1P_I.IAtE Z S. 00 445 OITLcr- /C7 Permit Information Date 5/5/2016 Permit Number 1001 Project Name Donna Bosley Applicant Name Right on Heating and Sheet Metal Inc. Applicant Address P.O.Box 758 City, State,Zip Lake Stevens,WA 98258 Contact Jeanie Graves Phone 425-335-4207 Email rightonheating@frontier.com Permit Type Residential Mechanical Site Address 3319 176th PI NE Valuation 0.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use HVAC Replacement Assigned To Kristin Foster Property Information Owner Information Parcel#:00621300009300 BOSLEY DONNA SUE BOSLEY DONNA SUE 3319 176TH PL NE 3319 176TH PL NE ARLINGTON,WA 98223 Contractors Contractor Name Primary Phone Email Contractor License License# Contact Type RIGHT ON 425-335- Labor& HEATING 4207 rightonheating@frontier.comCONTRACTOR Industries RIGHTHM988CM Review Date Type Description I Target Date Completed Date I Assigned To Status 5/5/2016 lResidential Mechanical 5/12/2016 lKevin Olander In Review Notes Date Note 5/5/2016 Furnace Model#TG8S040A08MP11 AFUE 80%A/C Model#TCHD18S41 S3 SEER 13 Uploaded Files Upload File Date File 5/5/2016 1027 28 AM 11001 So_ecs.odf 5/5/2016 10:27:28 AM 11001 Application.pdf RESIDENTIAL MECHANICAL PERMIT APPLICATION A Department of Community& Economic Development City of Arlington • 18204 59th Ave N E •Arlington,WA 98223•Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Addres0319 176th PI NE Project Description: HVAC replacement_Ductwork, demo, furnace, AC, venting, (2) fans, and gas piping (3) outlets Owner: Donna Bosley Address:3319 176th PI NE City: Arlington StateWa Zip Code: 98223 Phone: Serv-Pro#: 360-243-8313 Email:rightonheating@frontier.com Applicant: Contractor: Right On Heating -Jeanie Graves Address:PO 758 City: Lake Stevens State Wa Zip Code: 98258 Phone: 425-335-4207 Email: rightonheating@frontier.com CONTRACTOR INFORMATION Contractor Name:Right On Heating & Sheet Metal, Inc. Address: PO 758 City: Lake Stevens State:Wa Zip Code: 98258 License Number:RIGHTHM988CM Expiration. 02/14/2018 Phone:425-335-4207 Email:rightonheating@frontier.com STAFF USE ONLY Permit#: �,U� 1 Accepted by: Date: Received MAY 0 5 2016 BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afler000n - ' CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:3319 176th PI NE Permit#:1001 Parcel#:00621300009300 Valuation:0.00 OWNER_ APPLICANT CONTRACTOR Name:BOSLEY DONNA SUE Name:Right on Heating and Sheet Metal Inc. Name:RIGHT ON HEATING Address:3319 176TH PL NE Address:P.O.Box 758 Address:2213 131st Avenue NE City,State Zip:ARLINGTON,WA 98223 City,State Zip:Lake Stevens,WA 98258 City,State Zip:Lake Stevens,WA 98258 Phone: Phone:425-335-4207 Phone:425-335-4207 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:RIGHT ON HEATING Name: Address:2213 131st Avenue NE Address: City,State,Zip:Lake Stevens,WA 98258 City,State,Zip: Phone: 425-335-4207 Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2012 STORIES: I CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED r THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1I0/IRC1I0. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By Dfitc CONDITIONS Duct Testing is required per the 2012 Washington State Energy Code RI O1.4.3.1, An Air Leakage test is required per the 2012 Washington State Energy Code R402.4.1.2.Additional Requirements: 3" concrete pad with seismic bracing attached to pad;provide electrical disconnect; Lines shall be insulated-the use of adhesive tape is not permitted. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 5/16/2016 Furnace $25.00 5/16/2016 Gas Outlets Base Fee 1 to 5 $10.00 5/16/2016 Heat Pump $25.00 5/16/2016 Mechanical Permit Base Fee $25.00 5/16/2016 Vents $10.00 Total Due: $95.00 Total Payment: $0.00 Balance Due: $95.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon ha'114 S ®o r-zJP�.1 w-z Z S_ 00 l464r 41,5 DacL-r- 1� 95, oa Permit Information Date 5/5/2016 Permit Number 1001 Project Name Donna Bosley Applicant Name Right on Heating and Sheet Metal Inc. Applicant Address P.O.Box 758 City, State,Zip Lake Stevens,WA 98258 Contact Jeanie Graves Phone 425-335-4207 Email rightonheating@frontier.com Permit Type Residential Mechanical Site Address 3319 176th PI NE Valuation 0.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use HVAC Replacement Assigned To Kristin Foster Property Information Owner Information Parcel#:00621300009300 BOSLEY DONNA SUE BOSLEY DONNA SUE 3319 176TH PL NE 3319 176TH PL NE ARLINGTON,WA 98223 Contractors Contractor Name Primary Phone Email Contractor License License# Contact I I I Type RIGHT ON 425-335- (Labor& HEATING 4207 rightonheating@frontier.comCONTRACTOR (Industries 121GHTHM988C Review Date Type Description I Target Date Completed Date I Assigned To Status 5/5/2016 iResidential Mechanical 5/12/2016 JlKevin Olander In Review Notes Date Note 5/5/2016 IFurnace Model#TG8S040A08MP11 AFUE 80%A/C Model#TCHD18S41S3 SEER 13 Uploaded Files Upload File Date File 5/5/2016 10:27:28 AM 11001 Secs df 5/5/2016 10 27:28 AM 11001 Ao lication. df IV - ' RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE•Arlington,WA 98223•Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Addres0319 176th PI NE Project Description:HVAC replacement: Ductwork, demo, furnace, AC, venting, (2)fans, and gas piping (3) outlets Owner: Donna Bosley Address:3319 176th PI NE City: Arlington State Wa Zip Code: 98223 Phone: Serv-Pro#: 360-243-8313 Email:rightonheating@frontier.com Applicant: Contractor: Right On Heating -Jeanie Graves Address:PO 758 City: Lake Stevens State Wa Zip Code: 98258 Phone: 425-335-4207 Email: rightonheating@frontier.com CONTRACTOR INFORMATION Contractor Name•Right On Heating & Sheet Metal, Inc. Address: PO 758 City: Lake Stevens State:Wa Zip Code: 98258 License Number:RIGHTHM988CM Expiration. 02/14/2018 Phone:425-335-4207 Email:rightonheating@frontier.com STAFF USE ONLY Permit#: too Accepted by: Date: Received MAY 0 5 2016 RESIDENTIAL MECHANICAL . . o ! PERMIT APPLICATION -v- Department of Community & Economic Development City of Arlington•18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES [� Furnace (80+) Model #TG8SO4OAO8MP11 AFUE 80% Heat Pump Model # AFUE HSPE Q AC Unit Model#TCHD18S41 S3 SEER 13 (� Freestanding Stove Li Fire Place Insert Outdoor BBQ el Gas Piping Solid-Fuel Appliance Other Gas Piping Information Not Applicable: ❑ Pipe Material: Black Steel Pipe Size: r Distance From Meter to Furthest Appliance: 60' Total BTU's of all Appliances: 120K • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances o7ew"C6 a �CZUeQ- Applicant Signature: — Date: 05/05/2016 Applicant Printed Name: Jeanie L Graves I hereby certify that the above information is correct and that the construction,installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. COMMERCIAL MECHANICAL PRESSURE PIPING INFORMATION Department of Community& Economic Development City of Arlington •.18204 59th Ave NE•Arlington, WA 98223•Phone(360)403-3551 If gas piping will be installed, this form is required in addition to a Commercial Mechanical Permit Application Pipe Material: Inlet Pressure: Pressure Drop, Specific Gravity: Pressure Piping Schematic Show Pipe Size(s)and Lengths)from meter to all appliances, ❑ Scale or ❑ Not to Scale -- NOTE: any interior pressure �- regulators C must be � indicated Li Q �w NOTE; drip �e YL�Q�e legs/sediment traps are required at all appliances unless I integrated in the listed appliance "OT i t hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accordance with the laws, rules and regulation of the State of Washington. Applicants Signature J3!9 Print Applicants Name ' 556454-YTG-E-0914 DESCRIPTION �, The 13 SEER Series condensing unit is the outdoor part of a versatile system of air conditioning.It is designed to be custom- YOR matched with one of UPG's complete line of evaporator sections, with each serving a specific function.Matching Air Handlers are available for upflow,downflow,or horizontal applications to pro- Technical Guide vide a complete system. Electric Heaters are available, If re- quired.Add-On coils are available for use with upflow,downow, or horizontal furnaces and air handlers. SPLIT-SYSTEM AIR CONDITIONERS 13 SEER-R-410A- 1 PHASE FEATURES 1.5 THRU 5 NOMINAL TONS • Performance-Efficiency levels from 13.0 SEER/11.0 EER with a loose coil up to 16.0 SEER/14.0 EER(some models) MODEL TTCHD18 HRU 60 when coupled with an ECM indoor blower. • Small Footprint-Compact'slim-line design allows for easy installation in tight spaces.Units can be stacked two-high with approved stacking kit, • QuietDriveTm System-The combination of a swept-wing fan,rigid base pan,isolated compressor compartment,and quiet scroll compressor reduce sound to as low as 70 dBA. • Low Operating Sound Levels-The swept-wing condenser •• fan in blow-through configuration provides for whisper-quiet operation by allowing air to flow smoothly and efficiently across the fan tips. • Quality Condenser Coils-The coil is constructed of alumi- num microchannel tubing and enhanced aluminum fins for compact size and increased efficiency. • EnvironmentallyFriendlyRefrigerant-Thenextgenera- tion refrigerant R-410A delivers environmentally friendly per- formance with zero ozone depletion. GOOd HOUS81( hi - Durable Finish-Heavy-gage steel cabinet and tubular base N,f Promises 9 ® rails provide added support. ryfo R IfRQ><nt -, AMERI CAN Aesthetic-Powder paint Champagne"color provides an at- r� QUALITY tractive retail finish. DESIGNED,eNGINEERED P. Commercial Applications-The TCHD 3 Phase Series is al- 47616nYA810, ® ASSEMBLED IN 11E USA so available in 2081230-3-60 and 460-3-60 voltages in the I50 9001 2%,3,4, &5 ton models. Certified Quality Management System us Other Features: Due to continuous product improvement,specifications are sub- — Factory supplied Filter drier ject to change without notice. — High pressure switch,low pressure switch -- Accumulator and crankcase heater in all sizes Visit us on the web at — Up to 200'line set out of the box www.upgn et.cofn and WWW.york.Com — Zero lot line-only 6"minimum clearance from structure Additional rating information can be found at Agency Listed-Safety certified by CSA to UL 1995/CSA www.ahridirectory.org 22.2.Performance certified to ANSI/AHRI Standard 210/240 in accordance with the Unitary Small Equipment certification WARRANTY SUMMARY program. Extended 10-year limited parts warranty. Standard 10-year limited compressor warranty. Extended 10-year limited parts warranty requires online registration within 90 days of purchase for replacement or clos- ing for new home construction. 'Does not apply to R-22 models,3-Phase models,or Internet sales. See Limited Warranty certificate In User's Information Manual for details. FOR DISTRIBUTION USE ONLY-NOT TO BE USED AT POINT OF RETAIL SALE 556454-YTG-E-0914 Physical and Electrical Data MODEL TCHD18 TCHD24 1 TCH➢30 TCHD36 TCHD48 TCHD60 S41 1S4 S41S3 S41S3 I S41S3 Unit Supply Voltage 208-230V,I�,60Hz Normal Voltage Range 1 187 to 252 Minimum Circuit Ampacity 11.8 18.3 17.5 23.1 27.1 34.3 Max.Overcurrent Device Amps 2 20 30 30 40 45 60 Min.Overcurrent Device Amps 3 15 20 20 25 30 35 Type Scroll Scroll Scroll Scroll Scroll Scroll Compressor Rated Load Amps 9.0 13.5 12.8 17.3 20.5 26.3 Locked Rotor Amps 48.0 58.3 64.0 96.7 115.0 134.0 Crankcase Heater Yes Yes Yes Yes Yes Yes Factory Extemal Discharge Muffler No No Nu No No No Factory External Check Valve No No No No No No HS Kit Required with TXV 4 No No No No No No Fan Diameter Inches 17.5 23 23 23 23 23 Rated HP 1/8 114 1/4 1/4 114 1/4 Fan Motor Rated Load Amps 0.6 1.5 1.5 1.5 1.5 1.5 Nominal RPM 840 850 850 850 850 850 Nominal CFM 1150 3200 3200 3200 3050 3050 Face Area Sq.Ft. 5.76 11.96 11.96 11.96 13.96 13.96 Coil Rows Deep 1 1 1 1 1� 1 Fins/Inch 23 23 23 23 23 23 Max.Length 200 200 200 200 200 200 Max.Lift 65 65 65 65 65 66 Refrigerant Max.Drop 150 150 150 150 150 150 Liquid Line Set OD(Field Installed) 3/8 3/8 318 3/8 318 3/8 Vapor Line Set OD(Field Installed) 3/4 3/4 3/4 314 7/8 7/8 Unit Charge(Lbs.-Oz.)6 2-10 4-1 4-0 4-8 5-6 5-6 Charge Per Foot,Oz. 0.62 0.62 0.62 0,62 0.67 0.67 Operating Weight Lbs. 130 195 1 195 215 240 250 1. Rated in accordance with AHRI Standard 110-2012,utilization range"A". 2. Dual element fuses or HACR circuit breaker.Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker.Minimum recommended overcurrent protection. 4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model. 5. When mcre than 50 feet of tntaroonnecting tubing and more then 30 feet of vert cal lift is used,consult the Application Data(part number 247077).For long-line ap- pticatons,interconneahng lines over 100 feet must be Installed with liquid line solenoid. 6, The Unit Charge Is correct forthe outdoor unit,smalesl matched Indocrund.and 15 feet of refrigerant tubing.For tubing lengths other than 15 feet,add or subtract the amount of refrigerant,using the difference in actual lineset length(not equivalent length)mufbplied by the perfect value. Dimensions Refrigerant Unit � Connection Model (Inches) i Service Valve size C A B C Liquid Vapor 18 25-1/4 17-112 37-1/4 24 37-1/4 20 45 A 30 1 37-1/4 20 45 3/4 36 37-1/4 20 45 318 48 43-1/4 20 45 60 43-1/4 20 45 7/8 All dimensions are in inches and are subJectto changewithout notice. Overall height is from bottom of mounting feet to top of unit. Overall length and width include mounting feet and screw heads. �B 2 Johnson Controls Unitary Products 556454-YTG-E-0914 System Charge for Various Matched Systems Outdoor Unit TCHD18S41S3 TCHD24S41S4 TCHD34S41S3 TCHD36S41S31 TCHD48S4133 TCHD60S41S3 Required TXV 1,2 4171 4F1 4G1 4G1 01 4K1 Indoor Unit 3,4,6 Additional Charge,Oz AHE18B 4 _ - AHE24B 17 14 - AHE30B 17 14 10 - AHE36C 24 20 16 12 - AHE42D 32 27 22 - AHE48D 11 - AHE60D 16 13 AHR18B 4 - AHR24B 14 AHR30B 10 AHR368 16 12 - AHR42C 22 AHR48D 11 - AHR60D 16 - AHV18B 0 AHV24B 13 9 - - AHV30B 14 9 0 - AHV36C 21 16 7 0 - AHV42D ! 18 11 - - AHV48D 10 0 - AHV60D - I - 4 0 FC/MC/PC18 4 - - FC/MC/PC24 4 0 FC/MC/PC32 17 14 10 6 - - FC/MC/PC35 17 14 10 6 - FC/MC/PC37 24 21 16 12 - IFC/MC/PC43 20 16 0 - FC/MC/PC48 32 27 22 0 FC/MC/PC60 - 10 - iFC/MC62 - - 16 1 0 FC64 - 25 11 HD24 26 17 - - - HD36 32 20 14 11 - - HD48 - 33 24 H060 - - 30 22 UC18 5 - - - - UC24 9 1 5 1 UC48 - 25 21 17 6 UC60 - - - 11 - Some of the combinations shown in the above System Charge table require Advanced Main Air Circulating Fan indoor product.For approved coil only matches,please see the"COOLING CAPACITY-Upflow,Downflow&Horizontal Furnaces and Coils"table. FOOTNOTES: 1. For applications requiring a TXV use S1-iTVM"'series kit. 2. ATXV kit must be used with these indoor units to obtain system performance. 3. Systems matched with furnaces or air handlers not equipped with blower-off delays may require blower Time Delay Kit 81-2FD06700224. 4. PC coils cannot be used in downflow or horizontal applications.FC coils cannot be used In horizontal applications- 5. Refer to Cooling Performance Data tables for actual system performance for specified system matches. PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the outdoor unit,the smallest matched indoor unit,and 16 feet of interconnecting line tubing. 2. Verify the TXV and additional charge required for speck matched indoor unit In the system using the above table. 3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table, 4. For indoor matches requiring additional charge,the refrigerant needs to be weighed in for specific:matched indoor unit and actual lineset length. 5. Permanently mark the unit nameplate with the total system charge.Total System Charge=Base Charge(as shipped)+charge adder for matched indoor unit +charge adder for actual lineset length, Johnson Controls Unitary Products 3 556454-YTG-E-0914 ACCESSORIES Start Assist Kit(S1-2SA067)-Provides increased starting tor- que for areas with low voltage.See Hard Start Kit Accessory In- Refer to Price Manual for specific model numbers. stallation Manual for Hard Start Kit part number for each model. Application Limits TXV Kits-S1-1TVM series thermal expansion valves precisely Maximum Lineset Equivalent Length 200 Ft meter refrigerant for optimum performance over a wide range Outdoor Ambient Temperature Limits of conditions.See System Charge table for TXV part number Cooling Operation Maximum DB 115'F for each model. Minimum DB 50°F Low Ambient Pressure Switch Kit(S1-2LA06700424)-Al- Long Lineset Applications-For installations with more than lows the use of air conditioning at low outdoor ambient temper- 76 of equivalent Ilneset length,refer to the current version of atures down to+20°F(-70C). For use with single-stage models the Piping Application Guide 247077-UAD-H-0209,available containing R-410A refrigerant only, In the Application Bulletins seoliun un UPGnet. Off Cycle Timer Delay-Provides a 5-minute off cycle to pre- Thermostats-Compatible thermostat controls are available through accessory sourcing.For optimum performance and in- vent rapid recycling of the compressor. stallation,refer to the UPGNET'Low Voltage Wiring Diagram" document to select and apply controls. SOUND POWER LEVEL-TYPICAL OCTAVE BAND SPECTRUM(without tone adjustment) Model Octave Band Sound Power Level(db re.1-pW) Number 63 125 250 500 1000 2000 4000 8o00_ dBA SQI —� TCHD1884133 71 71 76 65 62 57 52 48 70 19.0 TCHD24S41S4 73 78 69 67 65 60 57 58 70 19.1 TCHD30S41S3 73 78 69 67 65 60 57 58 70 19.1 T0HD36S41S3 74 77 68 67 66 61 58 58 71 19.1 TCHD48S41S3 75 1 81 70 68 66 61 58 58 72 19.0 TCHD60S41 S3 73 1 81 1 71 67 fifi 61 58 59 72 19.2 Rated in accordance with ARI Standard 270 MOUNTING HOLE GRAPHIC r —28 06 V 20.38 7.50—� Fn 18.73 1023 , SMALL CABINET LARGE CABINET Johnson Controls Unitary Products 23 556454-YTG-E-0914 TYPICAL INSTALLATION THERMOSTAT WEATHERPROOF A' DISCONNECT SYATCH \� NEC CLASS 1 WIRING 0"CLEARANCE ` AROUND PERIMETER \ ♦ TO FURNACE OR K AIR HANDLER ♦ TERMINAL BLOCK ♦ NEC CLASS 2 WIRING TO INDOOR UNIT AIRP DIRELCTIOOI N NOTES: ALL OUTDOOR WIRING MUST BE WEATHERPROOF CAN BE STACKED TWO-HIGH WITH APPROVED STACKING KIT MINIMUM 16*CLEARANCE SAL OPEMNG(S)WITH FOR CONTROL ACCESS PANELS pERMAGUMOREOUIVANT TYPICAL FIELD WIRING ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE(NEC)ANDIOR LOCAL CODES POWER WIRING POWER WIRING 20Rf230-1-60 E4 VOLT CONTROL WIRING — CONTROL WIRING MINIMUM 1S GA.WIPE FACTORY WIRING _ I I (NEC CLASS 2) FURNACE OR AIR HANDLER TERMINAL BLOCK lR W \ I I I I I I TERMINAL W IS ONLY CONTACTOR REQUIRED ON SYSTEMS TERMINALS WITH HEAT. GND. COIL ram, LUG _ _ _ _ S — J (� (v1�{ I CONDENSING UNIT ROOM THERMOSTAT ALL OUTDOOR WIRING MUST HE WEATHERPROOF. USB COPPER CONDUCTORS ONLY, 24 Johnson Controls Unitary Products 556454-YTG-E-0914 COOLING PERFORMANCE DATA - AIR CONDITIONER MODEL NO. TCHD18S41S3 _ INDOOR COIL MODEL NO. FC/MC/PC24 AIR TEMP.ENTER- IDCFM 460 600 _ 750 lNG OUTDOOR UNIT ID pB(°F 80 80 75 80 80 BO 80 75 80 80 80 80 75 80 BO (°F) ID WB(°F) 57 62 62 67 72 57 62 62 67 72 57 62 1 62 67 72 T.C. 17.3 18.2 18.6 1,971 21,5 18.9 19.0 119.2 20.6 22.5 20.4 19.7 19.8 21.5 23.4 65 S.C. 16.6 14.5 12.6 1221 9.9 18.0 16.9 L 14.3 14.21 10.7 19.4 19.3 15,9 16.2 11,6 KW 1.07 1 1.08 1.09 1.08 _1.07 1.07 1.07 1.09 1.071 1.07 1.07 1.07 1.08 1.07 1.08 T.C. 16.2 1 17.31 17.8 18,9 20.7 17.8 18.2 18.4 19.7 21.5 19.4 19.1 19.0 20.5 22.3 75 S.C. 15.7 1 13.9 1 12,2 11.8 9.6 17,2 16.4 13.9 13.7 10.5 18.7 18.8 15.6 15.6 11.4 KW 1.28 1.28 1.28 1.27 1.25 1.27 1.27 1.27 1.26 1.25 1.26 1.26 1.27 1.26 1.26 T.C. 15.1 16.5 16.9 18.1 120.0 16.7 17.5 17.6 18.9 20.5 18.3 18.5 18.2 19.6 21.1 as S.C. 14.8 13.3 11.8 11.4 9.3 16.4 15.8 13.5 13.1 10.2 1&0 18.4 15.3 14.9 11.2 KW 1,48 1.48 1.471 1.46 1.44 1.46 1.46 1.46 1.45 1.43 1.44 1.44 1.46 1.44 1.43 T.C. 14.0 15.7 16.1 1 17.3 19.2 15.6 16.8 1 16.B ,18.0: 19.6 17.3 18,0 17.4 18.7 19.9 96 S.C. 14.0 12.7 11,3 11.0 8.9 15.6 15.3 13.1 }2.6 10.0 17.3 17.9 14.9 14.2 11.0 KW 1.68 1,68 1.66 1.64 1.62 1.65 1.66 1.65 1:64: 1.61 1.83 1.63 1.64 1.63 1.61 T,C, 13.4 14,5 14.9 16.0 18,1 14.8_ 15.6 15.6 16.8 18.5 16.3 16.7 16.2 17.6 18.9 105 S.C. 13.3 12.2 10.7 10.4 8.5 14.8 14.5 12.4 12.0 9.5 16.3 16.7 14.1 13,7 10.5 KW 2.16 2.12 2.11 2.12 1.93 2.08 2.06 2.07 2.04 1.92 1.99 1.99 2.02 1,95 1.91 T,C. 12.7 13,5 13.7 14.7 16.9 14.0 14.5 14.4 15.6 17.4 153 15.6 15.1 16.5 17.9 115 S.C. 12,6 11.6 10.0 9.8 8.0 14.0 13,6 11.6 11.5 9.0 15.3 15.6 13.2 -13-.2T 1o.o KW 2.63 2,54 2.56 2.68 2.23 2.48 2.44 2.47 2.42 2.21 2.34 2.34 2.40 2.27 1 2.20 T.C. 12.1 12.4 12.6 13A 16.8 13.2 13.4 ' 13.2 14.4 16.3 14.3 14.4 13.9 15.5 16,8 125 S.C. 12.0 11.1 9.4 9.2 7.6 33.1 -2.8 10.9 10.9 8.5 14.3 14.4 12.4 12.7 9.5 KW 3.10 2.97 3.00 3.04 2.53 2.89 2.83 2. 88 2.81 2.51 2,69 2,68 2.77 2.58 2.49 NOTE:ALL CAPACITIES INCLUDE INDOOR FAN HEAT.KW VALUES ARE FOR THE SYSTEM(OUTDOOR+INDOOR). Blue shaded cells are AHRI conditions.Green shaded cells are ACCA(TVA)conditions. Multipliers for determining the performance with other indoor sections. NOTE:For dry bulb temperatures different than those listed(between 73-87'F),sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 STUH per 1000 CFM per degree below the listed temperature. Air Handlers Coils 11.041.02 .C. KW Furnaces Coils T.C, S.C. KW - FC/MC/PC24 .00 1.00 T`(8,L)C'Al2 FClMClPC18A 1.01 1.10 0.92 FC/MClPC32 .00 1.00 T"(8,L)C*Al2 FCIMClPC24A 1.03 1.06 0.93 - FC/MC/PC35 .00 1.00 T*(8,L)C"Al2 FCIMC/PC32A 1.02 1.04 0.92 FC/MC/PC37 .01 1.00 T'(B,L)C'Al2 FC/MC/PC37A 1.04 1.07 0.93 HD24 02 1.01 T*(B,L)C'Al2 HD24 1.06 1.10 0.93 - UC24 99 1.00 T*(B,L)C*Al2 HD36 1.03 1.02 0.92 AHE18B - .02 0.92 T*(8,L)C'Al2 UC18A 1.01 1.11 0.92 AHE24B - 03 0.91 T*(8,QG'Al2 UC24A 1.03 1.06 0.93 AHE30B 03 0.91 T*(8,L)C*B12 FC/MC/PC1813 0.99 1.09 0.91 AHE36C - 1.08 1.16 0.93 T*(8,L)C'B12 FCIMCIPC24B 1 1,02 1,03 0.91 AHR186 - _ --fl;gg - g *8,L)6*B12 FG/MC/PC35B 1-4:03--1.06- 0.92- AHV18B - 1.00 1.01 0.96 T"(8,L)C'B12 HD24 1.06 1.06 1 0.91 AHV2413 - 1.01 1.02 1 T'(8,L)C*812 HD36 1.03 1.02 0.92 AHV30B 1.02 1,10 1 T'(8,L)C'B12 UC18B 1.00 1.10 0.91 AHV36C - 1.03 1.09 0.9J T*(8,L)C*B12 UC24B 1.02 1.04 0.90 MV12B FCIMC24B 1,02 1.02 0.93 T-(8,L)C'C16 FCIMCIPC35C 1.03 1.06 0.91 MV12B FC/MC35B 1.02 1.04 0.93 T'(8,L)C'C16 IHD36 1.03 1 1.02 0.91 MX12BN21 FC/MC18B 1.00 1.01 0.96 T'(B,L)V'Al2 FC/MCIPC24A 1.03 1 1.06 0.93 MX12BN21 FCIMC24B 1.02 1.03 0.9d T*(8,L)V'Al2 FC/MC/PC32A 1.02 1.04 0.92 MX12BN21 FC/MC35B 1.02 1.04 0,94 T*(e,L)V'Al2 FC/MC/PC37A 1,04 1.07 0.93 MX16CN21 I FC/MC35C 1.01 1.02 1 1.03 1T*(8,L)V*Al2 HD24 1.06 1.10 0.93 T*(8,L)V*Al2 HD36 1.03 1.02 0.92 T'(8,L)V*Al2 UC24A 1.03 ( 1.06 0.93 T*(8,L)V*B12 FCIMC/PC24B 1.02 1.03 0,91 T'(8,L)V'B12 FC/MCIPC358 1.03 1,06 0.92 T*(8,L)V'B12 HD24 1.06 1.06 0.91 T'(8,L)V*B12 HD36 1.03 1.02 0.92 T'(8,L)V'612 UC24B 1.02 1.04 0.90 Johnson Controls Unitary Products 25 Searcfi L&ISEARCH 4LjLFSafety&Health 40 Claims&Insurance Workplace Rights la Trades&Licensing 0- • !! aIndustries Washington State Department of "Labor & Industries RIGHT ON HEATINGISHT METAL INC 1 Owner or tradesperson P O BOX 758 2213131STAVE NE Principals LAKE STEVENS,WA 98258 GIPSON,KATHLEEN MARIE,PRESIDENT 425-335-4207 GIPSON,MARK WAITE,SECRETARY SNOHOMISH County Doing business as RIGHT ON HEATING/SHT METAL INC WA UBI No. Business type 602170 524 Corporation Governing persons KATHLEEN MARIE GIPSON MARK WAITE GIPSON; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no RIGHTHM988CM Effective—expiration 02/14/2002—02/14/2018 Bond OLD REPUBLIC SURETY CO $12,000.00 Bond account no YLI243178 Received by L&I Effective date 02/0112008 01/04/2008 Expiration date Until Canceled Insurance AMCO Ins Co $1,000,000 00 Policy no ACP3016790314 Received by L&I Effective date 09/28/2015 09/28/2015 Expiration date 09/28/2016 Insurance history Savings • e--/1 No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings ac its during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 004,991-01 Doing business as RIGHT ON HEATING Estimated workers reported Quarter 1 of Year 2016"11 to 20 Workers" L&I account representative T2 I LINDA ALGUIRE(360)902-4678-Email:POTH235@lni.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for A"1Vashinglon' J a o� Permit#: 1001 Permit Date: 05/05/16 Permit Type: RESIDENTIAL MECHANICAL Project Name: Donna Bosley Applicant Name: Right on Heating and Sheet Metal Inc. Applicant Address: P.O. Box 758 Applicant, City, State, Zip: Lake Stevens, WA 98258 Contact: Jeanie Graves Phone: 425-335-4207 Email: rightonheating@frontier.com Scope of Work: HVAC Replacement Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 05/17/2016 Permit Expires: 11/17/2016 Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00621300009300 3319 176TH PL NE BOSLEY DONNA 111 Single Family SUE Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# Right on Heating and 425-335-4207 PO Box 758 CONSTRUCTION UBI 602 170 524 Sheet Metal,Inc. CONTRACTOR Right on Heating and 425-335-4207 PO Box 758 CONSTRUCTION Labor&RIGHTHM988CM Sheet Metal,Inc. CONTRACTOR Industries Plan Reviews Date Review Type Description Assigned To Review Status 05/05/2016 RESIDENTIAL BUILDING MECHANICAL Fees Fee Description Notes Amount Forced Air Heat fee per Btu $25.00 Gas Piping/Units Enter#of units $10.00 Heat Pump/Heat Exchangers $25.00 Mechanical Base Permit Fee $25.00 Vents $10.00 Total $95.00 Attached Letters Date Letter Description 05/16/2016 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 05/17/2016 Jeanie Graves 59652513 cc $95.00 Outstanding Balance $0.00 Notes Date Note Created By: 05/16/2016 Will require blower door&Duct test Kevin Olander 05/05/2016 Waiting for the gas piping portion of the application. Kristin Foster 05/05/2016 Furnace Model#TG8S040A08MP11 AFUE 80%A/C Model#TCHD18S41S3 SEER 13 Kristin Foster Uploaded Files Date File Name 07/07/2016 1714006-1001 Issued Permit.pdf 05/06/2016 1608718-1001 Gas Piping.pdf 05/05/2016 1605419-1001 Application.pdf 05/05/2016 1605420-1001 Specs.pdf