Loading...
HomeMy WebLinkAbout19927 67th Ave Ne_BLD3147_2026 L CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 19927 67th Avenue NE Permit#:3147 Permit Expiration Date: 10/31/2020 Parcel#:31051400200700 Valuation: 16074.00 OWNER APPLICANT CONTRACTOR Gayteway Business Park,LLC Signs Plus,Inc Signs Plus P.O.Box 1727 766 Marine Drive 766 Marine Drive Bellevue,WA 98009 Bellingham,WA 98225 Bellingham,WA 98225 360-393-1265 360-671-7165 LIC:SIGNSPT952IN FXP:06/16i2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC. #: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Sign CODE YEAR: 2015 STOR1ES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATNG CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTII.A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRCI 10. SALES TA!{NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax turn form and coded City of Arlington#3101. Al�Cr k�CA✓ftS 2b `7 Zo Signature Print Name Date Released By ) CONDITIONS ADHERE TO APPROVED PLANS.JOB COPY SHALL BE ONSITE FOR INSTALLATION AN INSPECTIONS.SIGN ,;RAr r NIC)T RF f OCATT-r)WTTNTN TPF'CrTV'¢ Cr( PT VTCTRTT TTV A PP A AT fATTRACF!`TTnXFQ nun ADr rrrriTrnri ML'—)IPAL CODE 20.48.042.CALL FOR INSPE/--'�NS. THIS PERMIT AUTHORIZES ONLl THE WORK NOTED.THIS PERMIT COVERo WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. -�! PERMIT FEES Date Description Fee Amount 07/06/2020 Processing/Technology Fee $25.00 07/06/2020 State Surcharge-Commercial $25.00 07/06/2020 Signs $418.00 Total Due: $468.00 Total Payment: $0.00 Balance Due: $468.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon w K I CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 19927 67th Avenue NE Permit#:3147 Permit Expiration Date: 10/31/2020 Parcel#: 31051400200700 Valuation: 16074.00 OWNER APPLICANT CONTRACTOR Gayteway Business Park,LLC Signs Plus,Inc Signs Plus P.O. Box 1727 766 Marine Drive 766 Marine Drive Bellevue,WA 98009 Bellingham,WA 98225 Bellingham,WA 98225 360-393-1265 360-671-7165 LTC:SIGNSPI952LW EXP:06/16/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR j LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Sign CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law, or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1 l0/IRCI10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. ZZ Z� Signature Print Name Date Released By bk CONDITIONS ADHERE TO APPROVED PLANS. JOB COPY SHALL BE ONSITE FOR INSTALLATION AN INSPECTIONS. SIGN SHALL NOT BE LOCATED WITHIN THE CITY'S SIGHT VISIBILITY AREAS AT INTERSECTIONS PER ARLINGTON Permit#: 3147 Permit Date: 05/04/20 Project Name: Gayteway Business Park Bldg. C Site Address: 19927 67th Avenue NE Company/Applicant Name: Signs Plus, Inc Company/Applicant Address: 766 Marine Drive City, State, Zip: Bellingham, WA 98225 Contact: Kenneth E Dennis Phone: 360-393-1265 Email: ken@signsplusnw.com Permit Type: Sign Valuation: 16074.00 Square Feet: 0 Number of Stories: 0 Type of Construction: Occupancy Type: Scope of Work: New monument sign MIC/Opportunity Zone: Permit Issued: Permit Expires: 10/31/2020 DNU: Status: IN PROCESS Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 399 Other Gayteway Business 31051400200700 ]9927 67TH AVE NE Park,LLC Miscellaneous Manufacturing NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License# Signs Plus Kenneth Dennis 360-671-7165 766 Marine Drive CONTRACTOR Labor&Industries SIGNSPI952LW Plan Reviews Date Review Type Description Assigned To Review Status 06/10/2020 Sign Building In Review 06/10/2020 Sin Sign#2 location must be shown to meet sight triangle Approved with g Josh Grandlienard requirements Conditions ,. � � I I 06/10/2020 Sign Nova Heaton In Review Fees Fee Description Notes Amount Processing/Technology Fee $25.00 State Surcharge-Commercial Commercial Only $25.00 Signs Valuation Permit Fee Only $418.00 Total6>t:IIU. Notes Date Note Created By: 06/11/2020 Received a site plan with sign and utility locations. Kristin Foster 06/10/2020 Utility locations? Kristin Foster Uploaded Files Date File Name 06/11/2020 6808496-3220 Site Plan with Utilities.pdf 06/10/2020 6799637-3147 6-5-2020 Application,pff 06/10/2020 6799546-3147 Engineer Standards Authorization.pdf 06/10/2020 6799547-3147 6-5-2020 Plans.pdf 4 , Permit#: 3220 Permit Date: 06/10/20 Project Name: Gayteway Business Park Bldg. B Site Address: 20101 67th Avenue NE Company/Applicant Name: Signs Plus, Inc Company/Applicant Address: 766 Marine Drive City, State, Zip: Bellingham, WA 98225 Contact: Kenneth E Dennis Phone: 360-393-1265 Email: ken@signsplusnw.com Permit Type: Sign Valuation: 16074.00 Square Feet: 0 Number of Stories: 0 Type of Construction: Occupancy Type: Scope of Work: New monument sign MIC/Opportunity Zone: Permit Issued: Permit Expires: 10/31/2020 DNU: Status: PENDING PAYMENT Property Parcel# Address Legal Description Owner Name J Owner Phone Zoning 399 Other Gayteway Business 31051400200700 20101 67TH AVE NE Park,LLC Miscellaneous Manufacturing NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License# Signs Plus Kenneth Dennis 360-671-7165 766 Marine Drive CONTRACTOR Labor&Industries SIGNSPI952LW Plan Reviews Date Review Type Description Assigned To Review Status 06/10/2020 Sign Building in Review 06/10/2020 BLD Will need to verify signs will not be within the site Josh Grandlienard Approved with triangle Conditions I UI I.(,ZoZE� i 06/11/2020 BLD Nova Heaton Approved Fees Fee Description Notes Amount Processing/Technology Fee $25.00 State Surcharge-Commercial Commercial Only $25.00 Signs Valuation Permit Fee Only $418.00 Total $468A0 Notes Date Note Created By: 07/06/2020 Josh's conditions:Will need to verify signs will not be within the site triangle Kristin Foster 07/06/2020 KO approved on 7/2/2020 Kristin Foster 06/10/2020 Utility locations? Kristin Foster Ups Date File Name 06/11/2020 6809108-3220 6-5-2020 Plans.pdf 06/11/2020 6809107-3220 Engineer Standards Authorization.p_df 06/it/2020 6809106-3220 Gay ew•y Bldg.B Sign Application.pdf 06111/2020 6809105-3220 Site Plan with Utilitics.pdf Some L&I regional offices are now open on a limited basis by appointment only,for services that cannot be provided over the phone or online. Masks are required for in-person appointments.Call the office near you .(httr_jrir• gov/agenc contactaoffice-iocation for assistance,or call 360-902-5800 from 8 a.m.to 5 p.m. weekdays (except state holidays). wash��yio'snm o�yan...d Labor&IndusUies(httaswint.wa.gov). SIGNS PLUS INC Owner or tradesperson 766 Marine Dr. Principals BELLINGHAM,WA 98225 GRAVNING,DALE I.,PRESIDENT 360-671-7165 WHATCOM County SUTTERFIELD,JAMES M,PRESIDENT JEPPSON,KIM ELAINE,SECRETARY Doing business as SIGNS PLUS INC WA UBI No. Business type 602 475 651 Corporation Governing persons DALE GRAVNING DALE L GRAVNING; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. SIGNSPI952LW Effective—expiration 06/16/2005—06/16/2021 Bond Nationwide Mutual Ins Co $12,000.00 Bond account no 7900400684 Received by L&I Effective date 05/15/2013 06/13/2013 Expiration date Until Canceled Lexon Ins Co $6,000.00 Bond account no 9807850 Received by L&I Effective date 06113/2011 06/13/2011 Expiration date Until Canceled Insurance Mutual of Enumclaw Ins Cc $1,000,000.00 i Pol P0 CP CPP00242416500 Received by L&I Effective date 09/25/2019 10/09/2018 Expiration date 10/09/2020 Insurance history .Savings ................ .... No savings accounts during the previous 6 year period. LawaUits against the bond or savings o awsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Certifications & Endorsements OMWBE Certifications No active Certifications exist for this business. Apprentice Training Agent No active Washington registered apprentices exist for this business.Washington allows the use of apprentices registered with Oregon or Montana.Contact the Oregon Bureau of Labor&Industries or Montana Department of Labor &Industry to verify if this business has apprentices. Workers' Comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 090,281-00 Doing business as SIGNS PLUS Estimated workers reported Quarter 1 of Year 2020"21 to 30 Workers" L&I account contact T5/LINDSAY BARLOW(360)902-4735-Email:BLIN235@lni.wa.gov Public Works Requirements Verify the contractor is eligible to perform work on public works projects. Required Training—Effective July 1,2019 Exempt from this requirement. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace Safety& Health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 11/06/2019 Violations Inspection no. 317956357 Location 1041 N.Miller Ave Wenatchee,WA 98801 Inspection results date 10/15/2018 Violations Inspection no. 317951223 Location 17600 Southcenter Blvd. ^� Tukwila,WA 98108 Inspection results date 03/28/2018 Violations Inspection no. 317948436 Location 498 E 2nd St East Wenatchee,WA 98802 I i r SIGN PERMIT f APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE PLANS, INCLUDING STRUCTURAL CALCULATIONS WHERE APPLICABLE,TWO(2)FULLY DIMENSIONED PLOT PLANS SHOWING ALL SIGNS ON SITE. (EXISTING&PROPOSED) Project Address: 19927 67th Ave. N E ,(`jet L- 31051400200700 Parcel ID #: Lot#: Subdivision: Valuation: $16,074.00 Owner: Gayteway Business Park, LLC /Chris Gayte Phone Number: 206-240-9739 Address: 845 106th Ave. NE, Suite 102 City:Bellevue State: WA Zip Code: 98004 Contractor:SignsPlus 360-671-7165 Phone Number: Cell Phone: 360-393-1265 E-mail: ken@signsplusnw.com Address: 766 Marine Drive City:Bellingham State: W4 Zip Code: 98225 Contractor's License Number: EC SIGNSP1954LW Expiration: 6/16/2021 WALL SIGN CALCULATIONS MONUMENT SIGN CALCULATIONS Wall Height: Wall Length: Street Setback: Area of Wall: Height of Proposed Sign: 6-0" tall Sign Length: Sign Height: Width of Proposed Sign: 9'-4" wide Total Sign Area: Total Sign Print Area: 8.40 Sq. Ft. Total Sign Structure Area: 54 Sq. Ft. First Floor Square Feet First Floor Square Feet X .025= Is there other wall signage on the building? No_ Yes_ If yes, provide location and size of each sign. I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulations of the State of Washir,-, ^n ..-�._..._ c�ivrir�/r.CSi•...��vrN.J 05/04/2020 Applicants Signature Date Kenneth E. Dennis Print Applicants Name FOR STAFF USE ONLY Receivr�d Permit# Accept By Amount Received Receipt Datei4gdv�� ��� Kristin Foster From: ken@signsplusnw.com Sent: Monday, May 4, 2020 2:46 PM To: Kristin Foster Cc: Raelynn Jones; Launa Peterson Subject: RE: Gayteway Business Park Sign Permit Submittal [NOTICE: This message originated outside the City of Arlington mail system.-- DO NOT CLICK on links or open attachments unless you are sure the content is safe.] Kristin, I just filled out the other application for bldg. C 19927 67th Ave. NE. These signs are almost exact so the cost is half. $16,074.00 each. Don't forget to change the valuation on the original application I sent. Thanks have a great rest of your day. How long is the process taking now? Ken Dennis Senior Project Manager SIGNS PLUS !" 766 Marine Drive Bellingham, WA 98225 Cell: 360.393.1265 Tel: 360.671.7165 Email: ken@signsplusnw.com --------- Original Message --------- Subject: Gayteway Business Park Sign Permit Submittal From: "Kristin Foster" <kfoster@arlingtonwa.gov> Date: 5/4/20 1:22 pm To: "ken@signsplusnw.com" <ken@signsplusnw.com> Cc: "Raelynn Jones" <rjones@arlingtonwa.gov>, "Launa Peterson" <lpeterson@arlingtonwa.gov> Ken, Because there are two monuments signs to be constructed on two different parcels they will need to be permitted separately. Please provide an additional application for the second sign and revise the current i application accordingly. The aduress for Bldg. B is 20101 67th Avenue N,� and Bldg. C is 19927 67ch Avenue NE. Let me know if you have any questions. Thanks, Kristin Foster Permit Technician City of Arlington 18204 59th Ave NE 360-403-3549 kfoster@arlin =toy, nwa.gov 2 Kristin Foster From: Kristin Foster Sent: Monday, May 4, 2020 1:22 PM To: ken@signsplusnw.com Cc: Raelynn Jones; Launa Peterson Subject: Gayteway Business Park Sign Permit Submittal Ken, Because there are two monuments signs to be constructed on two different parcels they will need to be permitted separately. Please provide an additional application for the second sign and revise the current application accordingly. The address for Bldg. B is 20101 67th Avenue NE and Bldg.C is 19927 67th Avenue NE. Let me know if you have any questions. Thanks, Kristin Foster Permit Technician City of Arlington 18204 59th Ave NE 360-403-3549 kfoster@arlingtonwa.gov i Kristin Foster From: Kristin Foster Sent: Wednesday, May 6, 2020 11:19 AM To: ken@signsplusnw.com Cc: Raelynn Jones; Launa Peterson;Josh Grandlienard Subject: RE: Gayteway Business Park Sign Permit Submittal The reduction of the site wall will need to go before the Design Review Board prior to review of the sign permit applications. It sounds like Josh has been in communication with Gayteway to provide timelines for submittal in order to be added to the Design Review Board agenda. Until this process is complete the sign permit applications are on hold. Let me know if you have any questions. Thanks, Kristin Foster Permit Technician City of Arlington 18204 591"Ave NE 360-403-3549 kfoster@arlingtonwa.aov From: Kristin Foster Sent: Wednesday, May 6, 2020 8:21 AM To: ken@signsplusnw.com Cc: Raelynn Jones<rjones@arlingtonwa.gov>; Launa Peterson<Ipeterson@arlingtonwa.gov> Subject: RE: Gayteway Business Park Sign Permit Submittal Sign permit typically take about a week for review. Thanks, Kristin Foster Permit Technician City of Arlington 18204 59th Ave NE 360-403-3549 kfoster@a rl i ngtonwa.eov From: ken@signsplusnw.com <ken_ si nsplusnw.com> Sent: Monday, May 4, 2020 2:46 PM To: Kristin Foster<kfoster@arlinetonwa.eov> Cc: Raelynn Jones<riones@arlingtonwa.gov>; Launa Peterson <Ipeterson@arlinetonwa.aov> Subject: RE: Gayteway Business Park Sign Permit Submittal [NOTICE: This message originated outside the City of Arlington mail system.-- DO NOT CLICK on links or open attachments unless you are sure the content is safe.] Kristin, I just filled out the other application for bldg. C 19927 67th Ave. NE. 1 These signs are almost exact so the cost is half. $16,074.00 each. Don't forget to change the valuation on the original application I sent. Thanks have a great rest of your day. How long is the process taking now? Ken Dennis Senior Project Manager SIGNS PI-L15" ( Bmn�l:x ou1 <Ir INr Nn• 766 Marine Drive Bellingham, WA 98225 Cell: 360.393.1265 Tel: 360.671.7165 Email: ken(a�,sig_nsplusnw.com --------- Original Message --------- Subject: Gayteway Business Park Sign Permit Submittal From: "Kristin Foster" <kfosterQarlingtonwy .gov> Date: 5/4/20 1:22 pm To: "ken(cer?signsplusnw.com" <ken@signsplusnw.com> Cc: "Raelynn Jones" <rjones��arlingtonwa.gov>, "Launa Peterson" <lpeterson c,arlin tonwa.gov> Ken, Because there are two monuments signs to be constructed on two different parcels they will need to be permitted separately. Please provide an additional application for the second sign and revise the current application accordingly. The address for Bldg. B is 20101 671h Avenue NE and Bldg. C is 19927 671h Avenue NE. Let me know if you have any questions. Thanks, Kristin Foster Permit Technician City of Arlington 18204 59`h Ave NE 2 36b-403-3549 kfoster@arlin gtonwa.gov 3 Raelynn Jones From: ken@signsplusnw.com Sent: Tuesday, June 9, 2020 4:12 PM To: Raelynn Jones Subject: RE: Gayteway Sign Permit [NOTICE: This message originated outside the City of Arlington mail system.-- DO NOT CLICK on links or open attachments unless you are sure the content is safe.] Yes it is except the valuation on the sign at 20015 67th Ave. NE is $16,074.00 not$32,148.00. Both signs are $32,148.00, that is $16,074.00 each sign. Ken Dennis Senior Project Manager SIGNS PLUS inn vAllnn .autildt fhe Uuv 766 Marine Drive Bellingham, WA 98225 Cell: 360.393.1265 Tel: 360.671.7165 Email: ken@signsplusnw.com --------- Original Message --------- Subject: RE: Gayteway Sign Permit From: "Raelynn Jones" <rjones@arlingtonwa.gov> Date: 6/9/20 3:53 pm To: "ken@signsplusnw.com" <ken@signsplusnw.com> Hi Ken, are the permit applications initially submitted correct with the updated plans? Please advise.. Sincerely, Raelynn Jones Permit Technician 1 City of Arlington Community& Economic Development 18204 59th Ave NE Arlington, WA 98223 Office: 360-403-3436 www.arlinetonwa.gov f i I From: ken@signsplusnw.com <ken@signspIusnw.com> Sent: Monday,June 8, 2020 2:42 PM To: Raelynn Jones<rjones@arlingtonwa.gov> Cc: Kristin Foster<kfoster@arlingtonwa.gov>;Josh Grandlienard <joshg@arlingtonwa.gov> Subject: RE:Gayteway Sign Permit [NOTICE: This message originated outside the City of Arlington mail system.-- DO NOT CLICK on links or open attachments unless you are sure the content is safe.] Raelynn, I just sent the updated drawing and site plan for this. Ken Dennis Senior Project Manager 2 � SIGNS PLUS "' 766 Marine Drive Bellingham, WA 98225 Cell: 360.393.1265 Tel: 360.671.7165 Email: ken(a-)signsplusnw.com --------- Original Message --------- Subject: Gayteway Sign Permit From: "Raelynn Jones" <riones0carlin tog_nwa.gov> Date: 5/27/20 4:36 pm To: "ken ,signsplusnw.com" <ken u,signsplusnw.com> Cc: "Kristin Foster" <kfoster@arlingtonwa.gov>, "Josh Grandlienard" <joshg,@arl ingtonwa.gov> Good Afternoon Ken, We do have the sign permit application for the Gayteway Sign, however the site plan has changed since the original submittal. Please provide an updated site plan along with any other changes to ced c,arlingtonwa. gov for processing. Please feel free to reach out should you have any questions. I've attached the original submittal for your reference. I Thank you! Sincerely, 3 Raelynn Jones Permit Technician City of Arlington Community& Economic Development 18204 59th Ave NE Arlington, WA 98223 Office: 360-403-3436 www.arlingtonwa.gov 4 17235 N.75th Ave., Suite D145 • Glendale,AZ 85308 Ph: 888-856-6972 • Fax:602-789-9126 info@nwsigncouncil.org May 4, 2020 City of Arlington Attn: Community Development To whom it may concern: This letter shall serve as verification that Signs Plus, Inc. is authorized to use the engineering standards of the Northwest Sign Council for the following project: Gayteway Business Park 20015 67th Ave NE Arlington,WA 98223 Signs Plus, Inc. is a member in good standing with the Northwest Sign Council and has been trained in the proper use of the Northwest Sign Council engineering standards. Please call me if you have any questions. Respectfully, Patricia King Executive Director C: Signs Plus, Inc. Received JUN 0$IM NW 114 AN.}SW 1A OF SEC, "A T'sI R5F W W CIT'f OF ARI INGTON SNWMSH COUNP AA OFFICE OPYC z CITY OF ARLINGTON BUILDING DEPARTMENT APPROVED DATE BY NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR a a ► a s hPlrle� Irt?c' e._jej .fin.I. MAIN ENTRAN - Received ; 1 2Q20 ` = JUN .1 4 p z t'III WWI c�Yel pXIJJdI IC.f1 /� MONUMENT SIGN *'A'STREET NEW S"REET EWPLOESTRAN Lv Y NEN'STREET L UG*{'ON Ex PatLIGHT Q+I Ex POLE NEW pRP�'EWAY IGHT ON Ex POLE LIGHT jSTA 564751 [� ►'Z PER DIL X1 4 REMOVE Ex a r�N RrW REMOVE EX 'KXDING'C SE'I TALE ITYP} 67TH AVENUE NE I ncan is .w.r --"'1� i i • t a t, ^s c n 1 •�' ,f ►_ . •- ooyt ►1 ry r, a �,•• I �I5 I _ � _ •J. ,4. .I V fiCREEN WALL PTYP.I uj RELOCATE ExJI�L. eF Q)p RELOCATE EX C BOLLARDS TO END NE*Pf0E5'AfAN I NEW PEDESTAIAAI NEW STREET LIGHT REMOTE EX METER 1 BOLLARDS,EACH TO END �m,k Cr JAW prss W m W Oi EACH DRIVEWAY.; LIGHT NEW STREET LIGHT RFMM EX METER l LIGHT PER PLAN BY GATE VALVE PATCH SHBT SCREEN WALL TO EJ1f11 DFiIrFWAy lit ud �n.F (rypl I PATCH Ex ASPHALT yyl TRAFFEX,,TYPI EX ASPHALT TRAIL BACK OF CURB DUE 70 (TYPE. VM"tnA/hS �• 11C SHIFT SCREEN N'AL`a TG EX ASPHALT TROA TO NE CM Ex ASPS ANT TRAIL IfUAL WIDTH1 {TUI.WIDTH! STREET LIGHT LOCA''UN �� •TtttigBACx OF ClAi6 TD ALLOW rBE SAWCUT a PATCrED FORFCURBTON ILLL' IN AREAS OF TWjrkiMMIOTHi ION(AS BUILDING'S' — -- . - --_— -.1. ;"LBREAK IV SCREEN WALLDMRIOR� N 1TOUR s BUILDING C Z 67THAVE :::rl:Tu cla a� iRr�Ni aai.t+ REVISIONS y"iJw'NII'-Wi o�.W•CAR a&.FMCMG> 1.2A JOB SITE 2001567TH AVE. NE SIGNS -PLUS 15 4 "TN ST N( Fc"' PARCEL#'S 31051400200700 — — \ 766 Marine Drive n J Bellingham.WA 98225 J Z ( Phone 360.671.7165 r ;r F © slgnsplusnw.com v � g LAST SCREEN SITE MAP - cayleway BLI6IneS5 Park _ WALL SECTION 1 zso soon TO BE MOVE BACK TO ( nwN• 0413012020 r° x PARKING CURB TRUCK ' J 0 Q !',.qr�r M.ua1l+,F•I Ken Dennis '� FOR VISIBILITY BUILDING 'B' COURT ATtiT iTJ N NE ? I, I tap � - n�iovK;r � 22 tif.wmg",-otr. as rioted ^,'u ILIdgC - '' r' euLrnucn - 0 • 0 1 16'•Q' k vo&k-11 Dab]: 06102,12020 � ^" BwBixc s 7 � .tr. ..Y 25'VISI LITY • •••••.......... w D�aw, Draatnv Drodurgon 0 0 Y ( Client `Ign APploval — BUILDING Oct out.pllGr k4M ' BUi l+A1Gx ( 1 uj TRUCK ( Site map II.A Mly oec:.., tx 6T-0' -try - ••_..—. _ _ ^JG — COURT Z .g:2020 signs PI., This artsvarl, is the property of Signs Plus and is protected under slate and fed-1 copyrighr ia— Any use of Ihli an—rl, oche, than dire', business. wnh Signs ! a=-,r, Plus v.�ithout,+ntten permission shall ronsm Clio _/ % •^�• 1 ( your agreement tc purchase ibis--rl.,and mnt, _ �I MAP 'AnpO he design proposed per OS Copyright Law Tttle ( I TOE Chanter 5 3 s FIRST SCREEN E WALL SECTION L56'-O' Underwriters TO BE MOVED T U� Laboratories Inc.BACKTO 3 �.,, ,,,,,,s,0 PARKING CURB "v .�� v CITY OF ARLINGTON FOR VISIBILITY , ' E L9 g G BUILDING DEPARTMENT J INTERNATIONAL SIGN ASSOCIATION r C GAYTEWAY BUSINESS PARK 25'VISI ITY -----f7 APPROVED � �1------- - ��I __ 20015 67TH AVE. NE'p NORTHWESTSIGN COUNCIL �,. ARLINGTON,WA 98223 DATE gY 0 o 25'VISIBILITY J �wc4 p u.Fern�n°Icne. y NO CHANGES AUTHORIZED ti p p UNLESS APPROVED'BY THE BaMar1.RR°mm.t V _ r �yM BUILDING INSPECTOR ' .cr u«rcL.q rBbnk ChppnO Slsnm q . �. �v r° BaBF.�a�ae.p E °v SITE PLAN Received .6F°nose i.W GeFgw � . JUN 0 8 2020 p neyn.7.go raEReDwo q e SCALE: } =120' E COPY : : EPIC � v THIS 1)kMMNC DUES 11:}T C'ONSTIIU T PRODUCTION•REA,)�'ART'AORK ANP,IS TO HE USFC EXCI USiVEFY FOR PROOFING ANC)REVIFW PURPOSES 0NL Y ® ILLUMINATED MONUMENT SIGN C7 J� SIGNS PLUS 766 Manse Dive Bellingham.WA 98225 Phone 360.6 7 1.7165 9r4" 1, 8„ slgnsplusnw.com 8.-01, 1 -0" I 7•'0" 101, - i••o Gaylevmy BUSIIle55 Perk oo,za;2ozo SIGN GRAPHICS AREA I 75112"X 16"=8.4 SO.FT. olr,t t mma jw Ken Dennis ;ya,.,.• tap iµ.,red by 112'=1' AYTEWAY 0e,0212020 4 �-� Salo Rnai Producuor, r ra,•trig El nra,tr,g❑Dn„wing Chent Of C� Approval MAIN V' to c0 t ENTRANCE Project _ APProwl Cv 67TH AVE NE Pq� I Of 2. Ti u C4020 Signs Plus j Thw artwork as the SIDE VIEW o prop ern of Signs Plus and is protected Linde, state and federal copyright 1a• ..Any use of this ,artwork other than d,,"l business with Signs W Plus-thou),entree permission shall consnanc E your agreement to ptnchase this aiiwnrh.and Cthe design.pro;msed per W=Conynghl L",Trrlc 0 17;97 Chaplet 5 _ SIGN #1 SIGN COLORS MONUMENT SIGN Underwriters MAIN ENTRANCE MONUMENT v O SIGN AREA------- 8.40 SQ. FT. Laboratories Inca SIGN STRUCT ------ 54 SQ. FT DESCRIPTION: FABRICATE AND INSTALL ONE(1)S/S CENTER IDENTIFICATION WHITE ACRYLIC E LUMENS--------- 185 PER SQ. FT. MONUMENT SIGN W1 LED ILLUMINATED CENTER ID PANELS AND NON-ILLUMINATED 1 L � 'MAIN ENTRANCE"AND ADDRESS PANELS,BRICK BASE TO MATCH CENTER AND o GAYTEWAY COLUMN WRAPS. ■ MP GREY 0 INTERNAnONAL SIGN ASSOCIATION TO MATCH BUILDING Y stir ITEM No. ITEM DESCRIPTION NURTHWESTSIGN CUUNCII. t MPMAIN ENTRANCE 1 BASE PANEL WI BLUR/GREY BRICK TO LT.GREY TO MATCH BUILDING m 2 ILLUMINATED SIGN PANEL WI LED MODULES �. 3 112"WHITE ACRYLIC PUSH-THRU LETTERS MP DK.GREY 4 COLUMN WRAPS ■ TO MATCH BUILDING 5 ALUMINUM SQ.TUBE COLUMN ACCENT BARS 6 NON-ILLUMINATED MAIN ENTRANCE&ADDRESS PANELS BR ICKICK B EY SIMULATION OF o ILLUMINATED SIGN ° C 6 TM-_}RAN/INC DOES NO,CONS1ITUTE PROL);CTION REAEY ARTWORK AND IS 70 8F 11SEG EX LUSIUEIY r OR PROOFINi;AND REVIEW PURPOSES ONO ® ILLUMINATED MONUMENT SIGN #2 SIGNS PLUS 766 Marine Drive Belllrgham,WA 9817.5 Phone 360.671.7165 9-4 1,-8" slgnsplusnw.com 81-0" 1 r-0" 7r-Orr 10" L n Gayleway Business Park ante 03/24/2020 SIGN GRAPHICS AREA 75112"X 16"=8.4 SO.FL I,,i�'Lmngre. Ken Dennis \ O tap 2 1!2'=1 GAYTEWAY °P 3 BUSINESS PARK I Sales Fina' Production Drawing D awing D--g. c0ent b� O Aplxovnl ` c NORTH ENTRANCE / I N00ct AV. Approval j_© N 20015 67TH AVE NE 2of2 •' z G E2020 Signs Plus This artworle is the SIDESIDEVIEW O property of Signs Plus and is otAny Use under VIEW Y Y ° slate and federal copyrigfil laws Any use of this c arty rk other than dlrect husiness wnh Signs W Plus withow[s•ritten Permission shall­shtute E Your agreemeni to purcliase this armork. and C the design proposed Per[iS Copynght Law T,. 0 17.02 Chapter 5 E SIGN #2 SIGN COLORS MONUMENT SIGN NORTH ENTRANCE MONUMENT - S Underwriters SIGN AREA------- 8.40 SQ. FT. Laboratories Inc. SIGN STRUCT ------ 54 SO. FT, DESCRIPTION: FABRICATE AND INSTALL ONE(1)SIS CENTER IDENTIFICATION WHITE ACRYLIC E LUMENS --------- 185 PER SG. FT, MONUMENT SIGN W1 LED ILLUMINATED CENTER ID PANELS AND NON-ILLUMINATED M _ — — "MAIN ENTRANCE"AND ADDRESS PANELS.BRICK BASE TO MATCH CENTER AND ° GAYTEWAYCOLUMN WRAPS. ■ MP GREY INTERNAT10NA1 SIGN AssOCIATION TO MATCH BUILDINGBUS I NESS PARK ITEM NO. ITEM DESCRIPTION NORTHNIESTSIGN COUNCIL MP LT.GREY i BASE PANEL W/BLUR/GREY BRICK TO MATCH BUILDING m 2 ILLUMINATED SIGN PANEL W/LED MODULES 3 1/2"WHITE ACRYLIC PUSH-THRU LETTERS 3 MP DK,GREY T 4 COLUMN WRAPS TO MATCH BUILDING 5 ALUMINUM SO.TUBE COLUMN ACCENT BARS 6 NON-ILLUMINATED MAIN ENTRANCE&ADDRESS PANELS B EY o SIMULATION OF BRR ICKICK ILLUMINATED SIGN v HI.DRAVvING DOES NOT CONSTITUTE PRbOU tTION READY ART AND IS TO BE USED EXCLUSIVELY FOR PROOFING AND REVIEW PURPOSES ONLYLZ T DEEP CAISSON FOOTINGS 5"DEEP SIGN CABINETS DECORATIVE17 1 PLAN VIEW SIGNS PLUS END COLUMNS W/I'SQ.TUBE ` �— SCALE., 112"=V — ALUMINUM FRAME — —. 766 Marine Drive Bellingham,WA 98225 Phone 360.671 7165 2°X 2"X.187"STEEL BRICK VENEER slgnsplusnw-com ANGLE FRAME 9'-4" Client: Gayteway Business Park 1'-0" Date: 04/3012020 7'-0" - 10" Project Manager. Ken Dennis Designer: tap SIGN STRUCTURE AREA 108"X 72"-54 SQ.FT. Checked by: (3)5"X 1!2"THRU BOLTS -- TO STEEL POLES - - Drawing Scale: as noted Revision Date: 06/0212020 ELECTRICAL TOP CABINET DISCONNECT LED ILLUMINATED SWITCH — W/1/2"PUSH-THRU Final Production EDGE-LIT PLEX LETTERS E Drawlrlg 0 Drawing Drawing / — — _ Client Sign DECORATIVE nptrtuvil Date END COLUMNS W11"SQ.TUBE Q, 4 rrolcct a. sign APPta'al Dace: ALUMINUM FRAMES = in io MIDDLE 8 BOTTOM CABINETS NON-ILLUMINATED W/1/2"PLEX LETTERS — FLUSH MOUNTED C2020 Signs Pius I This artwork Is the property of Signs Plus and is protected under state and federal copyright laws.Any use of this r artwork other than direct business with Signs Plus without written permission shall constitute SIDEVIEW C your agreement to purchase this artwork,and "9 the design proposed per US Copyright Law Title y 17,192 Chapter S. 4"X 4'X.188"HSS SQ.TUBE 12'-8" ` O Undenmiters E Laboratories Inc.® FRONT ELEVATION SIDE VIEW E L19 SCALE; 1/2"=f' Q SCALE: 112"=f INMINAnONAL stag Assooanoii 24°DIA.X 7'DEEP CONCRETE c NORTHWEST SIGN COUNCIL CAISSON FOOTINGS N u u v 0 _ o _C k ____ _ _ _ | U ^ U ~`�mrnr�- | 9 COLUMN FINISHED CAISSON FOOTINGS GRADE NOTES O V-6" DIA. x 4'—C" DEEP 16 3'—D" DIA. x 10'-0" DEEP 1. POLES AND FOOTINGS ARE DESIGNED FOR SINGLE AND DOUBLE FAC=O SIGNS. 2, ALL INTERSECTION POINTS ON THE CHARTS MUST USE THE LINE ABOVE AND TO •111E 2O 2'-0" DIA. x 4'--0" DEEP 17 3'-6" DIA. x 10'-011 DEEP �'i+. RIGHT UNLESS THE POINT FALLS ON A LINE. �3 1'-6" DIA, x 5'-0" DEEP 18 3'-0° DIA. x 11'-0'I DEEP ; FrG• 3. SEE SHEET NWSC—WASHINGTON 04-0 FOR SPECIFICATIONS AND DESIGN CRITERIA. 4O 2'-0" DIA. x 5'-0" DEEP 19 S-6" DIA. x 11'-0" DEEP d 5 1'-6" DIA. x 6'--0" DEEP 20 4'---0" DIA. x 11'--O" DEEP rl © 2'—U" D;A. x 6'-01I DEEP 2 i 3'-0" DIA, x 12'-0" DEEP O;A. x T—O" DEEP 22 S-6" DIA x 12'-0" DEEP 8 '-0" DIA. x 7'—U" DEEP 23 4'-0" DIA. x 12'-0" DEEP 8" s MAx. b 2'-6" DIA. x 7'-0" DEEP 24 3'-6'I DIA. x 13'-0" DEEP �XAMP�C 10 2'-0" DIA. x 8'-0" DEEP25 4'-0" 01A. x 13'-0" DEEP. GIVEN: (HEIGHT�TO C F ,r CENTER OF SIGN) 8 14'-6'I, AND H 36'—O" = 11 2'-6" DIA. x 8'--0" DEEP 26 4'-6" DIA. x 13'--0" DEEP 12 3'—Q" DIA. x 8'-0" DEEP 27 4'-0" DIA. x 14'—O" DEEP CAISSON FOOT;NG CHART: FIND A x 8 ="445 S.F. AND DRAW A VERTICAL LINE UP TO 14TERSECT A HORIZONTAL LINE DRAWN FROM H = 36'. 13 2'-6" Q.A. x 9'-0" DEEP 28 4'-6" DIA. x 14'-0" DEEP USE THE LINE ABOVE AND TO THE RIGf-fT OF TIIE INTERSECTI N INT i ND PICK 14 3'-0" D.A. x 9'-0" DEEP 29 5'-0" DIA, x 14`-0" DEEP OUT A # 0 CA'.CSON. GO TO CAISSON FOOTINGS LIST FOR ! CASSONS AND SEE THAT HIS I. A 3'- 6"x13'--O" DEEP CAISSON. , 15 2'-6" D:A. x 10'--0" DEEP 30 4'-6" DIA, x 15'-0" DEEP 4 31 5'-0" DIA. x 15'-0" DEEP 32 5'-6" DIA. x 15'-0" DEEP 33 6'--0" DIA. x 15'--0" DEEP k A v. 1PJ07/2017 � w°F zvns���fd W N ""'SC-""A°+``DAM SCHNEIDER �� �� c 1I2/07/ten NWSC-WASHINGTON STRUCTURAL ENGINEERS F•1.M OCOICATION TO DTAU^TUNE INNOJAT,ON SIGN STANDARDS FOR 2015 EDMON OF THE WASHINGTON STATE BUILDING CODE 0"= oo14ENTB -•a Nu�-� 1-� «; LC�j'('RA L Pro�ct Number.11515t `Si� RA], Y �� w.wnn•��evri•xorwxwN,s tm.w. I�NAL :rrm�.:a�uity nna•.:.rtn urc v'i i t"J, o ch V SECTION MODULUS CHART(Zxl REQUIRED SECTION MODULUS FOR AREA AND HEIGHT OF SIGN 00 - 246 e7,,i 45 275 209 1474 40 C ` 126 iLLu 35 z j 9:1 0 1 rn 25 20 20 10 bu vu 10 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 .,290 300 . A x 5,AREA OF SIGN(SQUARE FEET) 12107017 0 SHM7 NW80-WA W2 DAW SCHNEIDER , W0712W STRUCTURAL ENGINEERS NWSC-WASHINGTON MYOONS FIRM UKk-�Tl.M TOSIGN STANDARDS FOR 2015 EDITION OF THE WASHINGTON STATE BUILDING CODE T�Axww~-I 0 PKJW mm6or,I lwl RA L S.* e SECTION MODULU5,-.Gf34U-p B THE FOLLOWING ARE THE MOST COMMONLY USED MEMBERS, GROUPED ACCORDING TO THEIR SECTION MODULUS LINE ON THE CHART, 1 1 SYMBOLS: Zx = SECTION MODULUS; HSS = STRUCTURAL TUBE; A _ DIA. STD. = STANDARD PIPE SECTION Zx = 0.5 Zx = 1.0 Zx = 2.0 Zx n3O I 2" DIA, STD. 2 1/2" DIA, S-D. 3" DIA. SID. 3 A. STD. I 1 HSS 2" x 2" x 3/16" HSS 2 1/2" x 2 1/2" x 3/16" HSS 3" x 3" x 3/16" HSS 3 1/2" x 3 1/2" x 3/16" USE 4X4X3/16" i ! TWO POLES MAY BE USED S i FOR A SINGLE SIGN. IF THIS ' IS THE CASE, USE HALF OF Zx = 4 Zx = 6 Zx = 10 Zx = 20 H ; � THE TOTAL SIGN AREA WHEN 4" DIA. STD. 5" DIA- STD. 6" DIA. STD. 8" DIA STD. � 1 USING THE CHARTS. HSS 4" x 4" x 3/16" HSS 4" x 4" x 5/16" HSS 5" x 5" x 5/16" HSS 6" x 6" x 1/2" HSS 5" x 5" x 3/16" HSS 6" x 6" x 3/16" HSS 7" x 7" x 5/16" i d i . 1 i Zx = 37 Zx = 53 Zx = 69 Zx = 91 - -- - 10" DIA. STD. 12" DIA. STD. 14" DIA. STD. 16" DIA. ST;?, �bj HSS 8" x 8" x 3/8" HSS 12" x 12" x 1/4" HSS 12" x 12" x 5/16" HSS 14" x 14" x 5/16" HSS 10' X i 0" X 1/4" R Zx = 116 Zx = 144 Zx = 175 Zx = 209 18" DIA. STD, 20" DIA. STD. 22" DIA. STD. 24" DIA, STD. HSS 14" x 14" x 3/8" HSS 14" x 14" x 1/2" HSS 14" x 14" x 5/8" HSS 16" x 16" x 1/2" EXAMPLE HSS 16" x 16" x 5/16" HSS 16" x 16" x 3/8" HSS 16" x 16" x 1/2" GIVEN: A 10'-0", 6 = 14'-6", H = 36'-0" (HEIGHT TO CENTER OF SIGN). SECTION MODULUS CHART: FIND A x B = 145 S.F. AND DRAW A VERTICAL LINE UP TO INTERSECT A HORIZONTAL LINE DRAWN FROM H = 36'. Sx = 246 Sx = 286 Sx = 324 26" DIA. STD. 28" DIA. STD. 30" DIA. STD.' THIS INi ERSEC110N PUINT FA'LLS B LOW Zx = 91. USE THE LINE ABOVE AND TO HSS 16" x 16" x 5/8" THE RIGHT OF THE INTERSECTION POINT. THEREFORE USE Zx = 91. 4 GO TO SECTION MODULUS UST FOR Zx = 91 AND PICK A POLE SIZE OF 16" D A. STD. PIPE OR 14" x 14" x 5/16" STRUCTURAL TUBE. i I 12/07/2017 K. sc A°[ATE SCHNEIDER cah 12/0712ov c�aED" oN To uTTF—OI LIINNN vAMONS !n a N11VSC-WASHINGTON SIGN STANDARDS FOR 2015 EDITION OF THE WASHINGTON STATE BUILDWG CODE ��oNs oommENTa �G^ 3 298�G�'�� �Db.Yk"1 b�It Y10 I—.uYo 1•wwuYM+. W�Y06/r.1¢W., 1 11.iM1"4MII., SIGN PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE•Arlington, WA 98223• Phone (360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE PLANS, INCLUDING STRUCTURAL CALCULATIONS WHERE APPLICABLE, TWO(2)FULLY DIMENSIONED PLOT PLANS SHOWING ALL SIGNS ON SITE. (EXISTING&PROPOSED) Project Address: 20015 67th Ave. N E Parcel ID#: 31051400200700 Lot#: Subdivision: Valuation: 32,148.00 Owner: Gayteway Business Park, LLC /Chris Gayte Phone Number: 206-240-9739 Address: 845 106th Ave. NE, Suite 102 City: Bellevue State: WA Zip Code: 98004 Contractor: SignsPlus Phone Number: 360-671-7165 Cell Phone: 360-393-1265 E-mail: ken@signspusnw.com Address. 766 Marine Drive City: Bellingham State: WA Zip Code: 98225 Contractor's License Number: EC S IG N S P 1954LW Expiration: 6/16/2021 WALL SIGN CALCULATIONS MONUMENT SIGN CALCULATIONS Wall Height: Wall Length: Street Setback: Area of Wall: Height of Proposed Sign: 6-0"tall Sign Length: Sign Height: Width of Proposed Sign: 9'-4" wide Total Sign Area: Total Sign Print Area: 8.40 Sq. Ft. Total Sign Structure Area: 54 Sq. Ft First Floor Square Feet First Floor Square Feet X .025= Is there other wall signage on the building? No_ Yes_ If yes, provide location and size of each sign. I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulations of the State of ashirn!n c�s,�c�16 &.e P r�cL� Kev_eeoe�o��oa9eea4a3doa9e3 05/04/2020 Applicants Signature Date Kenneth E. Dennis Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received 063 I 1 1 3M JOB SITE i1 $PAFNs9lpzxj0 20015 67TH AVE. NE SIG DNS 1 I uS •5 14-- - --- ------—ao4 --s: NG—L.—_ PARCEL#'S N 31051400200700 — — KARWOOD 2-U-.. •It I I9 ,.oa 766 Marine Drive CEMETERY a 0 0 1 Bellingham,WA 98225 a i (4655) Y Phone 360.671.7165 signsplusnwxom 20W " CONCRETE 0 b lD Z t SITE MAP BLOCK WALL Client-. Gayteway Business Park 0 250 500 ft � TO REMAIN L � ,mt w yo ,B 1 Date: 04/30/2020 + W g CONCRETE TRUCK 1 1 Project Manager. Ken Dennis --" ' _ BLOCK WALL COURT 1 �02 201sr sr NE W TO BE OMMITE aeo�Nc i. s n Designer: tap t _ Z FOR VISIBILITY 2-001 z:: a :. :i Checked by: '�' 1 - —' ---- KA N:coot ± 1 Drawing Scale: as noted W .i�.uuw�ul� Oil= - _ 1-017 1 126�-0 Revision Date: W - I BUMNI _< 2 1.017 2029 Sales nal Production -. r� J==a•.a-==a•..-�a'I,. I"�••a•�-••"� I ' �Drawing ❑FiDrawing Drawing 0016 -0 6 2��0 1 Client Sign "me 1 Approval Date 5 _ 1 Q — I — 1 Project Mgr Sign zax 11 I = Approval Date: m UIL IN C tofu eunraxcr 14 U 30'1 2-033 SWILDNI w 1 Site map TRUCK OLA ArN ,INyoos 3-M _ .._..__ COURT o _ '.' "' •---------�— ®2020 Signs Plus I This artwork Is the 00 01 -- property of Signs Plus and is protected under state and federal copyright laws.Any use of this r bMl CONCRETE — artwork other than direct business with Signs " —IVMWy BLOCK WALL Plus without written permission shall constitute rgmeer Museum,F "'^w' _ I 1 your agreement to purchase this artwork,and m u., TO REMAIN 1 ---- the design proposed per US Copyright Law Title ! + N I M swne.,ew raumhi g I 1 17/92 Chapter 5. q r z E CONCRETE 0' �^e BuOebinasou«p Anne „� BLOCK WALL + TO BE OMMITE 10 O Underwriters �ep.e=,s<mlres,n<p 55'-G' 3 � Laboratories Inc. d FOR VISIBILITY � � W Tsreo ,P9 Nutty$Junlryara Grill Q Ab,d—Man fl .nn+ 'Z QYai CI.�N�Q i` NlxNl MaMlne b Repal! !^" -� 1 M.I,g-C—eryp U - E Q 1 C INTERNAT10NAL SIGN AssociATION C G AYT E WAY BUSINESS PARK C11.►1�1 I �_�I�_�� I�_��I� Y /�/^y 20015 67TH AVE. NE-9 ARLINGTON, WA 98223 o b 0 NORTHWESTSIGN COUNCIL QJ ay,a„,� O i''';.,c,r Aerospace AMT 1 C ANnq 3 Caxielan Curler 9 ,�„ne un¢ee cnu.�n°r cnns!v ReshronFRommN Q Q K �,o,�.zm Rhne Charpnp Stap°nQ V 'e Sul— E°°!npr°pa°eo SITE PLAN { N b B ieMca!ns 0 Snoh°msh County U A b f Mesa Rosa Maimmance Sh°pSL o°n� r. � SCALE: 1"=120' o VRoaur,sr11 V T b E Regan O ChettSum E 6 C Ol THIS DRAWING DOES NOT CONSTITUTE PRODUCTION READY ARTWORK AND IS TO BE USED EXCLUSIVELY FOR PROOFING AND REVIEW PURPOSES ONLY ;Z ® ILLUMINATED MONUMENT SIGN SIGNS PLUS 766 Marine Drive Bellingham,WA 98225 Phone 360.671.7165 9'-4" 1'-8" signsplusnw.com 8'-0" 1' 0" T D" 10" Client: Gayteway Business Park Date: 03/24/2020 SIGN GRAPHICS AREA 75 1/2"X 16"=8.4 SQ.FT. Project Manager: Ken Dennis Designer: tap Checked by: GAYTE A 2 Drawing Scale: 1/2"=1' 3 Revision Date: 04/30/2020 v BUSINESS 4 Sales F 1 Final Production Drawing Drawing Drawing r— Client Sign —` rn bi Approval Dare MAIN ENTRANCE i WY Project Mgr. Sign ---- Approval Date: 20015 67TH AVE of 2 Ti 92020 Signs Plus This artwork is the SIDE VIEW property of Signs Plus and isprotected under 00 state and federal copyright laws.Any use of this c artwork other than direct business with Signs 61 Plus without written permission shall constitute E your agreement to purchase this artwork,and c the design proposed per US Copyright Law Title 0 I TQ Chapter 5. MONUMENT SIGN SIGN #1 SIGN COLORS MAIN ENTRANCE MONUMENT O Underwriters SIGN AREA------ - 8.40 SQ. FT. L Laboratories Inc. SIGN STRUCT --- - -- 54 SQ. FT. DESCRIPTION: FABRICATE AND INSTALL ONE(1)S/S CENTER IDENTIFICATION WHITE ACRYLIC E LUMENS --- - - ---- 185 PER SQ. FT. MONUMENT SIGN W'I LED ILLUMINATED CENTER ID PANELS AND NON-ILLUMINATED c • YTEWAY "MAIN ENTRANCE'AND ADDRESS PANELS,BRICK BASE TO MATCH CENTER AND o COLUMN WRAPS. ■ ti9P GREY 0 INTEMNATIONAI SIGN A6B$$O(IATION PARK TO MATCH BUILDING ITEM NO- ITEM DESCRIPTION NORTHWESTSIGN COUNCIL MAIN ENTRANCE 1 BASE PANEL W/BLUR/GREY BRICK MP LT.GREY N TO MATCH BUILDING 2 ILLUMINATED SIGN PANEL W/LED MODULES m 20015 67TH AVE NEti 3 1/2"WHITE ACRYLIC PUSH-THRU LETTERS MP DK.GREY a3 4 COLUMN WRAPS ■ TO MATCH BUILDING % u 5 ALUMINUM SQ.TUBE COLUMN ACCENT BARS u 6 NON-ILLUMINATED MAIN ENTRANCE&ADDRESS PANELS BLUR/GREY o SIMULATION OF BRICK ILLUMINATED SIGN o c THIS DRAWING DOES NOT CONSTITUTE PRODUCTION READYARTWORK AND IS TO BE USED EXCLUSIVELY FOR PROOFING AND REVIEW PURPOSES ONLY LZ ® ILLUMINATED MONUMENT SIGN #2 SIGNS PLUS 766 Marine Drive Bellingham,WA 98225 Phone 360.671.7165 9'-4" 1'-8" signsplusnw.com 8'-0" 1' 0" T D" 10" Client: Gayteway Business Park Date: 03/24/2020 SIGN GRAPHICS AREA 75 1/2"X 16"=8.4 SQ.FT. Project Manager: Ken Dennis Designer: tap Checked by: AYTE A 2 Drawing Scale: 1/2"=1' WY 3 Revision Date: 04/30/2020 v BUSINESS 4 Sales Final Production Drawing Drawing Drawing r- Client Sign —` rn bi Approval Dare rl - � in cfl i NORTH Project Mgr. Sign ---- Approval Date: 20015 67TH AVE M 2 of 2 Ti 92020 Signs Plus This artwork is the SIDE VIEW N property of Signs Plus and isprotected under 00 state and federal copyright laws.Any use of this c artwork other than direct business with Signs 61 Plus without written permission shall constitute E your agreement to purchase this artwork,and c the design proposed per US Copyright Law Title 0 I T'Q Chapter 5. MONUMENT SIGN SIGN #2 SIGN COLORS Z NORTH ENTRANCE MONUMENT SIGN AREA------ - 8.40 SQ. FT. O Underwriters L Laboratories Inc. SIGN STRUCT --- - -- 54 SQ. FT. DESCRIPTION: FABRICATE AND INSTALL ONE(1)S/S CENTER IDENTIFICATION WHITE ACRYLIC E LUMENS --- - - ---- 185 PER SQ. FT. MONUMENT SIGN W+LED ILLUMINATED CENTER ID PANELS AND NON-ILLUMINATED c • YTEWAY "MAIN ENTRANCE'AND ADDRESS PANELS,BRICK BASE TO MATCH CENTER AND o ] COLUMN WRAPS. ■ ti9P GREY 0 INTEMNATIONAI SIGN A$$O(IATION PARK TO MATCH BUILDING ITEM NO- ITEM DESCRIPTION � NORTHWESTSIGN COUNCIL NORTH ENTRANCE MP LT.GREY c 1 BASE PANEL Wi BLUR/GREY BRICK TO MATCH BUILDING 2 ILLUMINATED SIGN PANEL WI LED MODULES m 20015 67TH AVE NEti 3 112"WHITE ACRYLIC PUSH-THRU LETTERS MP DK.GREY a3 4 COLUMN WRAPS ■ TO MATCH BUILDING % u 5 ALUMINUM SQ.TUBE COLUMN ACCENT BARS U 6 NON-ILLUMINATED MAIN ENTRANCE&ADDRESS PANELS BLUR/GREY o SIMULATION OF BRICK ILLUMINATED SIGN o c THIS DRAWING DOES NOT CONSTITUTE PRODUCTION READYARTWORK AND IS TO BE USED EXCLUSIVELY FOR PROOFING AND REVIEW PURPOSES ONLY LZ 9'-4" 8'-0" 7'4" 10" SIGN STRUCTURE AREA SIGNS PLUS" 108"X 72"=54 SQ.FL 766 Marine Drive Bellingham,WA 98225 (6)5"X 1/2"THRU BOLTS Phone 360.671.7165 TO STEEL POLES signsplusnw.com Client. Gayteway Business Park ALUMINUM POLE COVERS Date: 04/3012020 W/1"SQ.TUBE FRAME 4"X.188"HSS SQ.TUBE � b) b Project Manager. Ken Dennis uO Zo Designer. tap ELECTRICAL Checked by: DISCONNECT SWITCH Drawing scale: as noted Revision Date: 314"X 8"X 16"BASE PLATES Sales Final Production 7/8"ANCHOR BOLTS Drawing Drawing Drawing Client Sign SIDE VIEW Approval Date 24"DIA.X 5'DEEP CONCRETE Project Mgr. Sign CAISON FOOTINGS Approval Late. Page: 02020 Signs Plus I This artwork is the property of Signs Plus and is protected under state and federal copyright laws.Any use of this artwork other than direct business with Signs Plus without written permission shall constitute C your agreement to purchase this artwork.and the design proposed per US Copyright Law Title FRONT ELEVATION SIDE VIEW ti 17N2 Chapter 5. L SCALE. 2 - ; SCALE 1 2 - 1 " Underwriters E Laboratories Inc. c 5'DEEP CAISON FOOTINGS 5"DEEP SIGN CABINETS E CINTERNATIONAL SIGN AS,,- ::'I!-' ALUMINUM POLE COVER c NORTHWESTSIGN COUNCIL o 3/4"X 8"X 16"BASE PLATES 2"X 2"X.187"STEEL BRICK VENEER W/2 EA.7/8"ANCHOR BOLTS ANGLE FRAME a3, u PLAN VIEW v 0 SCALE: 1/2'=1' c` 0 c v I r� ,ZS �� o�-t��<�'t�l�, v 3 ; I l CAISSON FOOTING CHART REQUIRED FOOTING SIZE FOR AREA AND HEIGHT OF SIGN 50 - 45 - - 28 / 2� 29 / 30 '- 40 - 17 13 32 35 12LLUJ W __--► 11 - 20 v> 0 30 10 21 F ❑ �,-.. 22 Z W u 23 O 8 = 25 24 — w 7 T � S 20 - --- — 15 10 — - JIn 1 In G 50 60 70 80 90 1.00 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 4 5 6 A x B,AREA OF SIGN(SQUARE FEET) 12/07/2017 H. IS S-IEET �F �VAS�Ij�C fd oWSC-WA04-1 ATE SVI INLIDER "�y-v O�ti / o NWSC—WASHINGTON 12/07I2017 STRUCTURAL ENGINEERS v} RE\9SIONS FIRM DEDICATION TO-R-T-1 INNOVATION SIGN STANDARDS FOR 2015 EDITION OF THE WASHINGTON STATE BUILDING CODE REVIEW COMnlENTs ",P,,°"'° °�°•'K�""° 'n' �`�' �0�,/G�T 39295 12/07/17 Pr*a Number.115451 �S BRA L F� °.,,,,�,°y>,,.°I>,w.l°•.�,P,�,,., e�.R..,E1�,I�,>rIP.� `SIGNAL 3.PPPLLWi W Q11LN u0 SI..LLl rqf X US!°POP COVS,MC:14xP J (-IC, �,wal Pay- A r�70. = 5(,r-, P +0 c-tr- Wl'-\PA 100J 3f tf LA c-tu,yll'� SECTION MODULUS CHART (Zx) REQUIRED SECTION MODULUS FOR AREA AND HEIGHT OF SIGN 50 - 246 45 - 1�75] 9 144 201 40 - 116 w z 35 - /L911 0 LL 69 LU 30 z Uj L) . ............. Hl 20 20 - 15 ...............— ...................... ------------------- 10 n 3a- 40 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 LO.5]/ 3.0 4.0 6.0 A x B,AREA OF SIGN(SQUARE FEET) 12/07/2017 1A. S WA SHEET NWSC-WA 04-2 AV Q� DATE 12/07/2017 SCHNEIDERAv: v NWSC-WASHINGTON STRUCTURAL ENGINEERSREVI IONS FIRM DEDICATION TO.1RU.—RAL--Al— SIGN STANDARDS FOR 2015 EDITION OF THE WASHINGTON STATE BUILDING CODE MMW COMWENTS I I ...... 39 12/07/17 Project Number:115451 URA L L Eli SECTION MODULUS GROUPS B THE FOLLOWING ARE THE MOST COMMONLY USED MEMBERS, GROUPED ACCORDING TO THEIR SECTION MODULUS LINE ON THE CHART. -------------- SYMBOLS: Zx = SECTION MODULUS; HSS = STRUCTURAL TUBE; A DIA. STD. = STANDARD PIPE SECTION , I Zx = 0.5 Zx = 1.0 Zx = Zx = 3.0 ------ II 2" DIA. STD. 2 1/2" DIA. STD. 3" DIA. STD. 3 1/2" DIA. STD. HSS 2" x 2" x 3/16" HSS 2 1/2" x 2 1/2" x 3/16" NSS 3" x 3" x 3/16" HSS 3 1/2" x 3 1/2" x 3/16" TWO POLLS MAY BE USED I FOR A SINGLE SIGN. IF THIS Zx = 4 Zx = 6 Zx = 10 Zx = 20 H IS THE CASE, USE HALF OF I THE TOTAL SIGN AREA WHEN 4" DIA. STD. 5" DIA. STD. 6" DIA. STD. 8" DIA. STD. USING THE CHARTS, HSS 4" x 4" x 3/16" HSS 4" x 4" x 5/16" HSS 5" x 5" x 5/16" HSS 6" x 6" x 1/2" HSS 5" x 5" x 3/16" HSS 6" x 6" x 3/16" HSS 7" x 7" x 5/16" I I I r d I I � I � I Zx = 37 Zx = 53 Zx = 69 Zx = 91 10" DIA. STD. 12" DIA. STD. 14" DIA. STD. 16" DIA. STD. HSS 8" x 8" x 3/8" HSS 12" x 12" x 1/4" HSS 12" x 12" x 5/16" HSS 14" x 14" x 5/16" b HSS 10" X 10" X 1/4" Zx = 116 Zx = 144 Zx = 175 Zx = 209 18" DIA. STD. 20" DIA. STD. 22" DIA. STD. 24" DIA. STD. HSS 14" x 14" x 3/8" HSS 14" x 14" x 1/2" HSS 14" x 14" x 5/8" HSS 16" x 16" x 1/2" EXAMPLE HSS 16" x 16" x 5/16" HSS 16" x 16" x 3/8" HSS 16" x 16" x 1/2" GIVEN: A = 10'-0", B = 14'-6", H = 36'-0" (HEIGHT TO CENTER OF SIGN). SECTION MODULUS CHART: FIND A x B = 145 S.F. AND DRAW A VERTICAL LINE UP TO INTERSECT A HORIZONTAL LINE DRAWN FROM H = 36'. Sx = 246 Sx = 286 Sx = 324 THIS INTERSECTION POINT FALLS BELOW Zx = 91. USE THE LINE ABOVE AND TO 26" DIA. STD. 2811 DIA. STD. 30" DIA. STD.HSS 16" x 16" x S/8" THE RIGHT OF THE INTERSECTION POINT. THEREFORE USE Zx = 91. . GO TO SECTION MODULUS LIST FOR Zx = 91 AND PICK A POLE SIZE OF 16" DIA. STD. PIPE OR 14" x 14" x 5/16" STRUCTURAL TUBE. 12/07/2017 SHEET NWSC-WA 04-3 A0 G'0 DATE - SCHNEIDERAVV 12/07/2017 STRUCTURAL ENGINEERS NWSC-WAS H I N GTON FIRM DEDICATION TO.-C-AL INNOVATION SIGN STANDARDS FOR 2015 EDITION OF THE WASHINGTON STATE BUILDING CODE REVISIONS „ss„sw s, Tsa,'—Iemvae+o I..,...,",,,r�,I<� �G Q 2107/17 OMMENTS Project Number:115451 O�L��TURA L9 V,F' iinii`:Ailowui.cisc'«.r•o swur�ar°r�°usi"rc�owinicrii"I�xscxrin.rnls naw 'C:�SIO` ^i "�� COLUMN FINISHED CAISSON FOOTINGS GRADE NOTES iO 1'-6" DIA, x 4'-0" DEEP IS 3'-0" DIA. x 10'-0" DEEP ;° \�'�� 1. POLES AND FOOTINGS ARE DESIGNED FOR SINGLE AND DOUBLE FACED SIGNS. ' 2. ALL INTERSECTION POINTS ON THE CHARTS MUST USE THE LINE ABOVE AND TO THE 2O 2'-0" DIA. x 4'-0" DEEP 17 3'-6" DIA. x 10'-0" DEEP ; •. RIGHT UNLESS THE POINT FALLS ON A LINE. ' 3 1'-6" DIA. x 5'-0" DEEP 18 3'-0" DIA. x 11'-0" DEEP '; _I FTG. 3. SEE SHEET NWSC—WASHINGTON 04-0 FOR SPECIFICATIONS AND DESIGN CRITERIA. 44 '-0" DIA. x 5'-0" DEEP 19 3'-6" DIA. x 11'-0" DEEP d ��� i• 5 1'-6" DIA. x 6'-0" DEEP 20 4'-0" DIA. x 11'-O" DEEP 1 �I ea © 2'-0" DIA. x 6'-0" DEEP 21 3'-0" DIA. x 12'-0" DEEP U7 1'-6" DIA. x 7'-0" DEEP 22 3'-6" DIA. x 12'-0" DEEPA. 4 U 2'-0" DIA. x 7 —6" DEEP 23 4'-0" DIA. x 12'-0" DEEP 8" [ '�• O MAX.2'-6" DIA. x 7'-0" DEEP 24 3'-6" DIA. x 13'-0" DEEP b EXAMPLE 10 2'-0" DIA. x 8'-0" DEEP 25 4'-0" DIA. x 13'-0" DEEP GIVEN: SIGN DIMENSIONS OF = 10'-0", B = 14'-6", AND H = 36'-0" (HEIGHT TO CENTER OF SIGN). 11 2'-6" DIA. x 8'-0" DEEP 26 4'-6" DIA. x 13'-0" DEEP CAISSON FOOTING CHART FIND A x B = 145 S.F. AND DRAW A VERTICAL LINE UP 12 3'-0" DIA. x 8'-0" DEEP 27 4'-0" DIA. x 14'-0" DEEP TO INTERSECT A HORIZONTAL LINE DRAWN FROM H = 36'. 13 2'-6" DIA. x 9'-0" DEEP 28 4'-6" DIA. x 14'-0" DEEP USE THE LINE ABOVE AND TO THE RIGHT OF THE INTERSECTION POINT AND PICK OUT A # ® CAISSON. GO TO CAISSON FOOTINGS LIST FOR CAISSONS AND 14 3'-0" DIA. x 9'-0" DEEP 29 5'-0" DIA. x 14'-0" DEEP SEE THAT THIS IS A 3'-6"xl3'—O" DEEP CAISSON. 15 2'-6" DIA. x 10'-0" DEEP 30 4'-6" DIA, x 15'-0" DEEP 31 5'-0" DIA. x 15'-0" DEEP 32 5'-6" DIA. x 15-0" DEEP 33 6'-0" DIA. x 15'-0" DEEP 12/07/2017 � �i• SCE SHEET wA5'�I�C f� NWSC-WA 04-4 S C H N E I D E R ,� ' CO DATE , NWSC—WASHINGTON 12/O7/2017 STRUCTURAL ENGINEERS FIRM DEDICATION TO STRUCTURAL INNOVATION SIGN STANDARDS FOR 2015 EDITION OF THE WASHINGTON STATE BUILDING CODE ZE\ REV ��, �G — ���' w� 39295 i REVIEW COMMENTS 12/07/17 Project Number:115451 �S URA L s.xss iRsds°wwelsure:muo ss•sfo er°srf,Ism f..GNlr°fsvasR:rnc rH;nce �TO`_�� {r� IS•IIlUVCUW OrSWN Y.O Sx•11Gilr lRrO fOI(Cwi1e(11Cr. ! 1V v SIGN PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE PLANS, INCLUDING STRUCTURAL CALCULATIONS WHERE APPLICABLE, TWO(2)FULLY DIMENSIONED PLOT PLANS SHOWING ALL SIGNS ON SITE. (EXISTING&PROPOSED) Project Address: 19927 67th Ave. NE Parcel ID#: 31051400200700 Lot#: Subdivision: Valuation: $16,074.00 Owner: Gayteway Business Park, LLC /Chris Gayte Phone Number: 206-240-9739 Address: 845 106th Ave. N E, Suite 102 City:Bellevue State: WA Zip Code: 98004 Contractor: SignsPlus Phone Number: 360-671-7165 Cell Phone: 360-393-1265 E-mail: ken@signsplusnw.com Address. 766 Marine Drive City:Bellingham State: WA Zip Code: 98225 Contractor's License Number: EC SIGNSP1954LW Expiration: 6/16/2021 WALL SIGN CALCULATIONS MONUMENT SIGN CALCULATIONS Wall Height: Wall Length: Street Setback: Area of Wall: Height of Proposed Sign: 6-0" tall Sign Length: Sign Height: Width of Proposed Sign: 9'-4" wide Total Sign Area: Total Sign Print Area: 8.40 Sq. Ft. Total Sign Structure Area: 54 Sq. Ft. First Floor Square Feet First Floor Square Feet X .025 = Is there other wall signage on the building? No Yes If yes, provide location and size of each sign. I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-described property will be in accordance with the laws, rules and regulations of the State of WashirGt,,.,.- - ic�r�t/n 05/04/2020 Applicants Signature Date Kenneth E. Dennis Print Applicants Name FOR STAFF USE ONLY I l _ Receiv(,rl a Permit# Accepted By Amount Received Receipt# Date l i d U 3•V.,,.l,-os � ��t-- 30°� JOB SITE 1 SPAFN E19102550 I � - .�. 20015 67TH AVE. NE SIGNS PLUS 'Ss 14 , PARCEL#S -- N 31051400200700 — — — — KARWOOD 2-�.. _ • ,oa 766 Marine Drive CEMETERY o z a 1 Bellingham,WA 98225 _i t I ' sp A 1 Phone a 360. I. 7165 (4655) ton CY I g o1 O gnsplusnwnw.com ._.__ Q7 2004 i u PLEASANT• HOME U F --- -- 'JOBILE t• — — LAST SCREEN - y2 K0 2 N t SITE MAP WALL SECTION Lim lo,o • 0 250 500 it I TO BE MOVE Client Gayteway Business Park fool w . oils 1• L f Date: 04/30/2020 x O O 0 " BACK TO W g PARKING CURB TRUCK f 1 Project Manager: Ken Dennis •U '� FOR VISIBILITY Z013T COURT 1 L�2 - Si NE W � B.no"w'E s n '� I' C Designer: tap z x W - u-�naa r H 2�0, 'E+ - Checked by: o •I,RBNG'C' "1p wa t- ilA N�soot Z � 1 Drawing Scale: as noted Q 1-0n 0 e 26'-0 Revision Date: 06/02/2020 •utaal n I BIRgtlG E +Aao� 25'VISI LITY tots ,-on --- Sales Final Production � �.�II��•a=�a� 25'VISIB = �Drawing �Drawing Drawing 0 e m E - 1 --- Client Sign 2416 2��0 — - 1 1 Approval Date Project Mgr; Sign j ------- euE�Bsicb• i 2-ON I r t I Approval Date: WL ING C 2-019 ,a ; 30'-o, •«IIDINGT 2-03J 2-034 I; 1 euIIRgN �.. d UJ Sitem E" AiN ,u95005: TRUCK— ,� ---�— COURT � - 2A18 - Z ®2020 Signs Plus I This artwork Is the 01 -- property of Signs Plus and is protected under state and federal copyright laws.Any use of this a�1 — 1 artwork other than direct business with Signs ,,,",,,� stlaequanian VMWy _ Plus without written permission shall constitute rgoneer Museum,F "'^w'' _ - 1 1 your agreement to purchase this artwork,and ---- 'a the design proposed per US Copyright Law Title V IC IFY M A swne ew umeinp I f --- 17N2 Chapter 5. = s FIRST SCREEN E BuOebEnaSou«p WALL SECTION a'n°x ��eGed TO BE MOVED 'A �e.Te,lsem"esIm9 IS Underwriters BACK TO 56'0" w Laboratories Inc. QNrr"s.lungaro Grill p PARKING CURB I ' "bao1R•rA.nN V° Gr.a,�I,�aO FOR VISIBILITY 1 �� p r NexNl N1acAlne b Repair Q w"h v AILVWnCemeM _ .E INTERNATIONAL SIGN ASSOCIATION y GAYTEWAY BUSINESS PARK 25'VISI LITY CL � l fl l l I� Y "°°�"°°0 = ARLI GTO ,W 9822NET9 VI NORTHWESTSIGN COUNCIL ARLINGTON,WA 98223VI psMi°r�rospa aAMT i e 0 25'VISIBILITY AN1 3 C°"ielan Curler 9 o„„", un"ed a,ur�n or cons,Q W T i BeshronFRommN O 0 v .w x ru Bnna Charpn°SlaaonQ V illy ns Re I.ng Ier sno reMcatns Q ppne9S.— Itroraan cam BbB SITE PLAN U AbF.— Em SCALE 1"=120' Pro*,,d.,nV TIER", o CheteSu. E Q C N THIS DRAWING DOES NOT CONSTITUTE PRODUCTION READY ARTWORK AND IS TO BE USED EXCLUSIVELY FOR PROOFING AND REVIEW PURPOSES ONLY LZ ® ILLUMINATED MONUMENT SIGN SIGNS PLUS 766 Marine Drive Bellingham,WA 98225 Phone 360.671.7165 9'-4" 1'-8" signsplusnw.com 8'-0" 1' 0" T D" 10" Client: Gayteway Business Park Date: 03/24/2020 SIGN GRAPHICS AREA 75 1/2"X 16"=8.4 SQ.FT. Project Manager: Ken Dennis Designer: tap Checked by: AYTEWAY 2 Drawing Scale: 1/2"=1' 3 Revision Date: 06/02/2020 v BUSINESS 4 Sales F 1 Final Production -__—— 5 Drawing Drawing Drawing r— - Client Sign —` _. -1 Approval Dare _ — iO (0 AFt iMAIN ENTRANCE Project Mgr. Sign -- Approval Date: 20015 67TH AVE M iii = - of 2 Ti 92020 Signs Plus This artwork is the SIDE VIEW property of Signs Plus and isprotected under 00 state and federal copyright laws.Any use of this c artwork other than direct business with Signs 61 Plus without written permission shall constitute E your agreement to purchase this artwork,and c the design proposed per US Copyright Law Title 0 I TQ Chapter 5. MONUMENT SIGN SIGN #1 SIGN COLORS MAIN ENTRANCE MONUMENT O Underwriters SIGN AREA------ - 8.40 SQ. FT. L Laboratories Inc. SIGN STRUCT --- - -- 54 SQ. FT. DESCRIPTION: FABRICATE AND INSTALL ONE(1)SIS CENTER IDENTIFICATION WHITE ACRYLIC E LUMENS --- - - ---- 185 PER SQ. FT. MONUMENT SIGN W.1 LED ILLUMINATED CENTER ID PANELS AND NON-ILLUMINATED c • YTEWAY "MAIN ENTRANCE'AND ADDRESS PANELS,BRICK BASE TO MATCH CENTER AND o 6associAtioN COLUMN WRAPS. ti9P GREY 0 INTENATIONAI SIGN A PARK TO MATCH BUILDING ITEM NO- ITEM DESCRIPTION NORTHWESTSIGN COUNCIL MAIN ENTRANCE 1 BASE PANEL W/BLUR/GREY BRICK MP LT.GREY N TO MATCH BUILDING 2 ILLUMINATED SIGN PANEL W/LED MODULES m 20015 67TH AVE NEti 3 1/2"WHITE ACRYLIC PUSH-THRU LETTERS MP DK.GREY a3 4 COLUMN WRAPS ■ TO MATCH BUILDING u 5 ALUMINUM SQ.TUBE COLUMN ACCENT BARS U 6 NON-ILLUMINATED MAIN ENTRANCE&ADDRESS PANELS BLUR/GREY o SIMULATION OF BRICK ILLUMINATED SIGN o c THIS DRAWING DOES NOT CONSTITUTE PRODUCTION READYARTWORK AND IS TO BE USED EXCLUSIVELY FOR PROOFING AND REVIEW PURPOSES ONLY LZ ® ILLUMINATED MONUMENT SIGN #2 SIGNS PLUS 766 Marine Drive Bellingham,WA 98225 Phone 360.671.7165 9'-4" 1'-8" signsplusnw.com 8'-0" 1' 0" T D" 10" Client: Gayteway Business Park Date: 03/24/2020 SIGN GRAPHICS AREA 75 1/2"X 16"=8.4 SQ.FT. Project Manager: Ken Dennis Designer: tap Checked by: AYTEWAY --- 2 Drawing Scale: 1/2"=1' 3 Revision Date: 04/30/2020 v BUSINESS 4 Sales F 1 Final Production -__—— 5 Drawing Drawing Drawing r- - Client Sign --` Approval Dare _ - � in cfl i NORTH ENTRANCE Project Mgr. Sign -- - - Approval Date: • • AVE M -' ' 2of2 Ti 92020 Signs Plus This artwork is the SIDE VIEW N property of Signs Plus and isprotected under 00 state and federal copyright laws.Any use of this c artwork other than direct business with Signs 61 Plus without written permission shall constitute E your agreement to purchase this artwork,and c the design proposed per US Copyright Law Title 0 I T'Q Chapter 5. MONUMENT SIGN SIGN #2 SIGN COLORS Z NORTH ENTRANCE MONUMENT SIGN AREA------ - 8.40 SQ. FT. O Underwriters L Laboratories Inc. SIGN STRUCT --- - -- 54 SQ. FT. DESCRIPTION: FABRICATE AND INSTALL ONE(1)S/S CENTER IDENTIFICATION WHITE ACRYLIC E LUMENS --- - - ---- 185 PER SQ. FT. MONUMENT SIGN W+LED ILLUMINATED CENTER ID PANELS AND NON-ILLUMINATED c • YTEWAY "MAIN ENTRANCE'AND ADDRESS PANELS,BRICK BASE TO MATCH CENTER AND o ] COLUMN WRAPS. ■ ti9P GREY 0 INTEMNATIONAI SIGN A$$O(IATION PARK TO MATCH BUILDING ITEM NO- ITEM DESCRIPTION � NORTHWESTSIGN COUNCIL NORTH ENTRANCE MP LT.GREY c 1 BASE PANEL W/BLUR/GREY BRICK TO MATCH BUILDING 2 ILLUMINATED SIGN PANEL W/LED MODULES m 20015 67TH AVE NEti 3 1/2"WHITE ACRYLIC PUSH-THRU LETTERS MP DK.GREY a3 4 COLUMN WRAPS ■ TO MATCH BUILDING % u 5 ALUMINUM SQ.TUBE COLUMN ACCENT BARS U 6 NON-ILLUMINATED MAIN ENTRANCE&ADDRESS PANELS BLUR/GREY o SIMULATION OF BRICK ILLUMINATED SIGN o c THIS DRAWING DOES NOT CONSTITUTE PRODUCTION READYARTWORK AND IS TO BE USED EXCLUSIVELY FOR PROOFING AND REVIEW PURPOSES ONLY LZ 7'DEEP CAISSON FOOTINGS 5"DEEP SIGN CABINETS C!�P) DECORATIVE - PLAN VIEW SIGNS PLUS END COLUMNS W/1"SQ.TUBE SCALE: 1/2"= 1' ALUMINUM FRAME 766 Marine Drive Bellingham,WA 98225 Phone 360.671.7165 �2"X2"X.187'STEEL BRICK VENEER slgnsplusnw.com ANGLE FRAME 91-4„ 1'-8" Client: Gayteway Business Park 8'-0" 1'-0" Date: 04/30/2020 7'-0" 10" Project Manager: Ken Dennis SIGN STRUCTURE AREA Designer: tap 108"X 72"=54 SQ.FT. (3)5"X 112"THRU BOLTS Checked by: TO STEEL POLES Drawing Scale: as noted Revision Date: 06/02/2020 ELECTRICAL TOP CABINET DISCONNECT LED ILLUMINATED SWITCH W/1/2"PUSH-THRU ❑Sales ❑Final ❑Production EDGE-LIT PLEX LETTERS Drawing Drawing Drawing Client Sign DECORATIVE Approval Date END COLUMNS W/1"SQ.TUBE o� `a ALUMINUM FRAMES � � W Date: r MIDDLE&BOTTOM CABINETS NON-ILLUMINATED W/1/2"PLEX LETTERS FLUSH MOUNTED Page. 02020 Signs Plus This artwork is the property of Signs Plus and is protected under state and federal copyright laws.Any use of this artwork other than direct business with Signs U Plus without written permission shall constitute I SIDE VIEW C your agreement to purchase this artwork.and !! ti the design proposed per US Copyright Law Title I 4"X 4"X.188"HSS SQ.TUBE 17/92 Chapter 5. 12'-6" in E O Underwriters Laboratorieslnc.- c ' FRONT ELEVATION SIDE VIEW E L SCALE: 1/2-= 1' SCALE: 1/2-= 1' IU INTERNATIONAL SIGN ASSOCIATION b a 24"DIA.X 7'DEEP CONCRETE v NORTHWESTSIGN COUNCIL CAISSON FOOTINGS m v a u v -- o 0 C N f= ��n q�§'�� �����'��� �a„�t. �•,�,,� =� � �„� �"��-tom��" �i� � a (—P, CAISSON FOOTING CHART REQUIRED FOOTING SIZE FOR AREA AND HEIGHT OF SIGN 50 45 15 16 28 25 Z9 . 40 17 i—_- z6 30 .... ---1 13 / 31 18 27 S2 35 12 19 33 W (7 11 20 Ap C 30 10 21 z o 22 W v O 8 23 / F- 24 W 7 S 20 r _ ti 1 15 _- 3 10 2 r • 1 � ,. 5 ---,- . 10 40 50 60 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 4 5 6 A x B,AREA OF SIGN(SQUARE FEET) a 12/07/2017 o °ir SHEEP e:.w:.T tiw w Ord MSC-WA ,TF SCHNEIDER _; ax �' STRUCTURAL ENGINEERS NWSC-WASHINGTON FIRM UYVIGATION TO SI NIiCIU A6M-1- SIGN STANDARDS FOR 2015 EDITION OF THE WASHINGTON STATE BUILIONS DING CODE Qs r+Ww cow m�,m> �, �T �,�oTU AL9 �G��w� 41tY,w[w.wwnawmiva AAiiPAIIfFI@B10HlIOi901RK AQ 'TONAL Ktl Nsusi4aT eaGwn�vMLLMe eEwtfa CYIipCI%M YY 3 IIr I i 6 e COLUMN FINISHED CAISSON FOOTINGS GRADE NOTE 1'-6" DIA. x 4'-0" DEEP 16 3'-0" DIA. x 10'-0" DEEP " �' a°: 1. POLES AND FOOTINGS ARE DESIGNED FOR SINGLE AVD DOUBLE FACED SIGNS. J i :4 2. ALL INTERSECTION POINTS ON THE CHARTS MUST USE THE LINE ABOVE AND T'0 'fHE ;,i. 2. 2—0 DIA. x 4—O DEEP 17 3'-6" DIA. x 10'-0" DEEP ; �a RIGHT UNLESS THE POINT FALLS ON A LINE. O 1'-6" DIA. x 5'-0" DEEP 18 3'-0" DIA. x 11'—D" DEEP FTG• 3. SEE SHEET NNrSC-49ASHINGTON 04-0 FOR SPECIFICATIONS AND DESIGN CRITERIA. 0 2'-0" DIA. x 5'-0" DEEP O 3'-6" DIA. x l l'—O" DEEP d LJJ 1'-6" DIA, x 6'--0" DEEP 2O 4'--0" D'.A. x i l'—O" DEEP ; - 2—0" D:A. x 6—0' DEEP 21 3—0 DIA. x 12—0 DEEP 0l'-6" D:A. x 7'-0" DEEP 22 3'--6" DIA. x 12'-0" DEEP 8 '-0" DIA. x 7'-0" DEEP 23 4'-0" DIA. x 12'-0" DEEP 8» s 9 2'-6" DIA. x 7'-0" DEEP 24 3'-6" DIA. x 13'-0" DE MAX. bEP EXAMPLE 10 2'-0" DIA. x 8'-0" DE-EP 25 4'-0" DIA. x 13'-0" DEEP• GIVEN: SIGN DIMENSIONS OF = 10'-0", E = 14'-6", AND H = 36'-0" (HEIGHT TO CENTER Of- SIGN). 11 2'-6" DIA. x 8'—C DEEP 26 4'-6" DIA. x 13'-0" DEEP =' 12 3'-0" DIA. x 8'-0" DEEP 27 4'-0" DIA. x 14'-0" DEEP CAISSON FOOT3NG CHART: FIND A x 8 = 145 S.F. AND DRAW A VERTICAL LINE UP TO INTERSECT A HORIZONTAL LINE DRAWN FROM H = 36. 13 2'-6" D.A. x 9'-0" DEEP 28 4'-6" DIA. x 14'-0" DEEP USE THE LINE ABOVE AND TO THE RIGHT OF THE INTERSECTION PINT AND PICK OUT A # @ CAISSON. GO TO CAISSON FOOTINGS LIST FOR C. SSONS AND i 4 3'-0" D:A, x 9'-0" DEEP 29 5'-0" DIA. x 14`-0" DEEP SEE THAT THIS IS A 3'--6"xl3' -O" DEEP CAISSON. 15 2'-6" D:A. x 10'-0" DEEP 30 4'-6" DIA. x 15'-0" DEEP A 31 5'-0" DIA, x 15'-0" DEEP 32 5'-6" D{A. x 15'-0" DEEP 33 6'--0" DIA. x 15'--0" DEEP • i S 12/07/2017 0 -WA C � N ISc—wA 04-4y' SCHNEIDER Mkt- �`� 12/07/2017 STRUCTURAL ENGINEERS 2 (� NWSC-WASHINGTON RECISIONS PIRMD'�1CATIdJTOSTAUCTU LINNOVATS N — 3295 9 SIGN STANDARDS FOR 2015 EDITION OF THE WASHINGTON STATE BUILDING CODE 12/07/T7 FrojeUNam�r 11545t '� $Ay �+ '� u.u,rks ua,.res�mrDmo wf.on.uu»1Drx.vcu wusr>nrwik,nw �SjO.NAL �C' Ii Is q IMYAAit'IXSk fFD swls KC'![t?tL I.Y(<PSSC:.:T6L ------------- ------------------------------------------------------------------------------- j. Ll At.10"Af (low elf SECTION MODULUS CHART LZx REQtJ IRET)SECTION MODULLIS FOR AREA AND HEIGHT OF SAGN 60 - -------------------------- -------------------- —-------------- 246 45 ------------------ 175 )9 209 E44 40 P E I 116 35 - 69 0 30 - Lu 0 37 25 - 52 L 3� U \L, Al 20 15 10 - 5/ 7 v I zu 30 4u tou lu 110 120 130 140 150 1650 170 180 190 200 210 220 230 240 250 260 270 280 .,290 300 Eli A x B,AREA OF SIGN(SQUARE FEET) r. 121071MV WAs SHEET NWSC-WA 04-2 0 DATE SCHNEIDER -6 too NWSC-WASHINGTON 1210712W STRUCTURAL ENGINEERS toSIGN STANDARDS FOR 2015 EDITION OF THE WASHINGTON STATE BUILDING CODE REOSIONS 39295 A AL Fad Y g SECTION MODUILt1S__jGfiQUPS B THE FOLLOWING ARE THE MOST COMMCNLY USED MEMBERS, GROUPED ACCORDING TO THEIR SECTION MODULUS LINE ON THE CHART. -------------- I SYMBOLS; Zx = SEC7i0.N MODULUS; HSS = STRUCTURAL TUBE; A DIA. STD. = STANDARD PIPE SECTION I Zx -_0.5 Zx = 1.0 Zx = 2.0 Zx 3.0 ; 2" DIA. STD. 2 1/2" DIA. S70. 3" DIA. SIU. 3 1 A STD. HSS 2" x 2" x 3/16" HSS 2 1/2" x 2 1/2" x 3/16" HSS 3" x 3" x 3/16" HSS 3 1/2" x 3 1/2" x 3/16" USE 4X4X3/16" i i TWO POLES MAY BE USED FOR A SINGLE SIGN. IF THIS H IS THE CASE, USE HALF OF Zx = 4 Zx = 6 Zx = 10 Zx = 20 THE TOTAL SIGN AREA WHEN 4" DIA. STD. 5" DIA. STD. 6" DIA. STD. 8" DfA, STD. I USING THE CHARTS. HSS 4" x 4" x 3/16" HSS 4" x 4" x 5/16" HSS 5" x 5" x 5/16" HSS 6" x 6" x 1/2" II HSS 5" x 5" x 3,/16" HSS 6" x 6" x 3/16" HSS 7" x 7" x 5/16" d I Zx = 37 Zx = 53 Zx = 69 Zx = 91 10" DIA. STD- 12" DIA. STD. 14" DIA. STD. 16" DIA. STD. b HSS 8 x 8 x 3/8 HISS 12" x Z x 1/4 HSS 12" x 12' x 5/16 HSS 14 x 14" x 5/16 HSS 10" X 10" X 1/4" Zx = 116 Zx = 144 Zx = 175 Zx = 2D9 3 18" DIA. STD. 20" DIA. STO. 22" DIA. STD. 24" DIA. STD. EXAMPIL HSS 14" x 14" x 3/8" HSS 14" x 14" x 1/2" HSS 14" x 14" x 5/8" HSS 16" x 16" x 1/2" HSS 16" x 16" x 5/16" HSS 16" x 16" x 3/8" HSS 16" x 16" x 1/2" GIVEN: A - 10'-0", B = 14'-6", H = 36'-0" (HEIGHT TO CENTER OF SIGN). SECTION MODULUS CHART: FIND A x 8 = 145 S.F. AND DRAW A VERTICAL UN= UP TO INTERSECT A HORIZONTAL LINE DRAWN FROM H 36'. Sx = 246 Sx = 286 Sx = 324 THIS INTERSECTION POINT FA'--LS BLOW Zx = 91. USE THE LINE ABOVE AND TO 26" DIA. STD. 28" DIA. STD. 30" DIA. STD. THE RIGHT OF THE INTERSECTION POINT. T.AEREFORE USE Zx = 91. HSS 16" x 16" x 5/8" GO TO SECTION MODULUS UST FOR Zx = 91 AND PICK A POLE SIZE OF 16" D:A, STD. PIPE OR 14" x 14" x 5/16" STRUCTURAL TUBE. i d 12/07/2017WA � kI. SrI� 0� swEEF NWSC-WA 04-3 _ o DATESCHNEIDER � z 12/07/2017 STRUCTURAL ENC�i VEERS NWSC--WASHINGTCN FIRMOSOICATaONTi4TRU TURA INN�VATIpN SIGN STANDARDS FOR 2015 EDITION OF THE WASHINGTON STATE BUILDING CODE RsI°NS o .nmc®x�lnm.asws,rssssal..- `�9295 � 12/07/17 115451 �s j�RA L7 mTm or.r"ccsxw�aa�+launuoeua ecwlia assaTexTRsm �+01��11 '" ''', Ii"�RAYtMRr Ci4Yn ND MI.IkriaV"^.IC4lUR'AY11fR, 3 1 v CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360403-3551 BUILDING PERMIT 19927 67th Avenue NE Permit#:3147 Permit Expiration Date: 10/31/2020 Parcel#:31051400200700 Valuation: 16074.00 OWNER APPLICANT CONTRACTOR Gayteway Business Park,LLC Signs Plus,Inc Signs Plus P.O.Box 1727 766 Marine Drive 766 Marine Drive Bellevue,WA 98009 Bellingham,WA 98225 Bellingham,WA 98225 360-393-1265 360-671-7165 LIC:SIGNSP19521M FXP:06/16i2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Sign CODE:YEAR: 2015 S1'Olwis: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATNG CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FWAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC l l0/1RC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax turn form and coded City of Arlington#3101. ew 0(4eftS 20 `7 Z-0 Signature Print Name Date Released By bde CONDITIONS ADHERE TO APPROVED PLANS. JOB COPY SHALL BE ONSITE FOR INSTALLATION AN INSPECTIONS. SIGN CHAT f vnT R17 f n(',\TT.r)WTT"TN THP ('fTV'C Cr( HT VTQTRTT ITV APTAQ AT T1\TTrDQF7CTTn\TQ DT7D Aor rmri-wNr.T ML'-)IPAL CODE 20.48.042.CALL FOR INSPE("�NS. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVExno WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PER',%1I I'FFM Date Description Fee Amount 07/06/2020 ProcessingfTechnology Fee $25.00 07/06/2020 State Surcharge-Commercial $25.00 07/06/2020 Signs $418.00 Total Due: $468.00 Total Payment: $0.00 Balance Due: $468.00 CALL POR INSFF�MONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon ilk INSPECTION REQUEST PROCEDURE To schedule an inspection: Call the Automated Inspection Line (360) 403-3417 Required Information: -Permit Number (Building, Right of Way or Civil) -Inspection Request (Type) -Inspection Time (am or pm) • A.M. inspections are scheduled from 8:00 am to 12:00 pm • P.M. inspections are scheduled from 1:00 am to 4:00 pm • You may request a specific time. We will do our best to honor the time requested. The Automated Inspection Line responds exactly like voicemail. Simply listen to the voice message and leave the information indicated above. You may stay on the line and request multiple inspections giving the required information each time. Inspections must be called in before 3:3 0 PM to be on the next day inspection schedule 9 Fire Suppression (fire alarm,fire sprinkler) inspection requests require at least 48 hours advanced notice To cancel or modify an inspection please call (360) 403-3433. CITY OF ARLINGTON INSPECTION CARD No building construction shall be commenced until permit holder INSPECTION RECORD SHALL or his agent has posted this Inspection Record Card in a REMAIN AT JOB SITE conspicuous place on the premises. OWNER: GAYTEWAY BUSINESS PARK,LLC CONTRACTOR: SIGNS PLUS,INC JOB ADDRESS: 20101 67TH AVE NE LOT NUMBER TYPE GROUP NATURE W WORK: NEW MONUMENT SIGN USE of BUILDING: WAREHOUSE/MANUFACTURING/OFFICE PERMIT No: BLD-3147 DATE ISSUED:7/6/2020 INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB DEPARTMENT INSPECTION DATE(S) PASS FAIL INITIALS FOOTING BUILDING FOUNDATION (360)403-3417 UNDERFLOOR SHEARWALL PLUMBING(groundwork) ROUGH PLUMBING GAS PIPING ROUGH HEATING&VENTILATION FRAMING INSULATION WALLBOARD(SHEAR/RATED WALLS) CEILING GRID STRUCTURALSLAB CROSS CONNECTION CONTROL IN PREMISE (360)403-3417 GRADING TEMPORARY TECSP ASBUILTS APPROVED MAINTENANCE BOND STORM DRAINAGE SYSTEM PAVING,SIGNAGE&MARKINGS LANDSCAPING CONDITIONS ONSITE UTILITIES WATER ONSITE UTILITIES SEWER Sewer OFFSITE UTILITIES WATER (360)403-3508 OFFSITE UTILITIES SEWER SEWER PRETREATMENT Water CROSS CONNECTION CONTROL PREMISE (360)403-3526 SIDE SEWER/CLEANOUT/FINAL WATER SERVICE INSTALLATION WATER SERVICE FINAL (360)403-3417 HYDRO/FLUSH UNDERGROUND**INCL FDC FIRE ALARM /AUTOMATIC SPRINKLER HOOD SUPPRESSION SYSTEM FINAL FIRE WALK-THROUGH (360)403-3417 FINAL INSPECTION ILL SIGNATURE BLOCKS MUST BE COMPLETE NIi 14 AND SN 1�4 DF SF,-- 'z Tt1N RSF A V CITY OF AR'.iNGTON Sh(>O MSH�7Ut1T• 'hA cn ...• � v v, z CITY OF ARLINGTON f BUILDING DEPARTMENT j1- APPROVED z I l l 1 1 1 W DATE BY NO CHANGES AUTHORIZED UNLESS APPROVED BY THE E BUILDING INSPECTOR ` A : . - -�- - JOB COPY Receiverl J U N 112020 a rMONUMENT SIGN �a y NEV1 STREETNEWSTREET NEW S'REE1 > NEWPEDESTRIAM W � �r IIG►<'ON EX tIGH T ON EX�F NEW DRNFNAY +GHT ONE' POLE> I CHT ISTA 56-ISI r1 f f! PER DiL X1 d REMOVE Ell -r rna�arn- REMOVE EX ;,SLALDING'C'SETT TREE(TYP} _ n*E m'°' 67TH AVENUE NE -- - •i• -- - 1 . _. .�.a_ r r- - - .I _ - - -- ff • . s�►-f-...��-...-...tea-.���� P' p y •1 I 1 + - I f 6CRFFN W m f mi rn m 1 RELOCATE EX 1 RELOCATE EX F, jl&L.ed+•►)es >- ea-LARDS TO END NEW PEDES"RiAN II NFM PFDESTTIiJW BO LARDS TO ENO rLam,r,R y�,,a�y 3 m OF EACH hHIvF��At_J LGHI NEW STREET LIGGHT L�HT NFh"STREET LIG►O' REMOVE Ex 1 TER i OF EACM DRIVEWAY REMOVE EX METER 8 Wr tAwn-cr too* PER PLAN BY GATE YAIVE PATCH SHIFT SCREEN WAIL TO ITYPI PATCH EX ASPHALT yy TRAFFEX!TYPi EX AVKk'TP*L BACK Of CURS DUE TO y Yit�r1s s 1� �"'•' SKr SCREEN*&;TO T EX ASPHAIT TRAIL TO NEW fftF HYDRANT TRAL ilFL L WIDTHI ;FULL Wm; STREET I Q BE SAWCUT i PATCHED PATCH EX ASPHALT ^ .-C�fT L TpN i�.S •lgN ('> BACX OF CURB TD ALLOW FN SGN ASSIrTy AREAS My TRAI II A L 0'HI FOR BREAK!v SCREEN*A.! DETERIORATION a,AS BUILDING BF- BUILDING 'C' TO FIT Srtdl OETERYINED BY CITY - 6TTN AVE - ::,v�1%r.;Ci,op :;Na�IN� F�.�r?±_•,•A� .REVISIONSr,.�•fit'-A',s-a NAi/L YL-PW:,Al ` � �__ � i• �� WFTN3 'Im 18 Why., JOB SITE Iu 20015 67TH AVE NE SIGNS PLUS PARCEL#'S 31051400200700 I — — 766 Manne Drive Gtc4FIGRf ¢ 'i I Bellingham,"A 9K2.5 C, Phone 360 671 7165 j c w O sisnsplusnw.corn SITE MAP LAST SCREEN 1 - V. 0 250 500 ft WALL SECTION 1 G<Ivl[?(u�,v€;,,. TO BE MOVE takcmW • " �- BACK TO r 04130 2020 7 0 0 a PARKING CURB p p TRUCK FOR VISIBILITY BUILDING tpl COURT <en Denn _ rT,St b't ryF u = 1 f n! rU(oiw ra ......... 22 is 2, " 11 . ......_« A.e 4✓<N ,IOotM]► Ley�!y ' He.Holed 2 06'0212020 .rf Z 25'VISI LITY ' 0 0 _ ` Client �Mo. . P rY a,aol, c An—al - 1 t Q -- I BUILDI i • '� NG C ac!anck � � Site map J.-kaw _ GLA AIM 41 TRUCK 'a; COURT 2 Z 2020 MS.% Phis i ih.,- oo-ork u,e o, nrnpc--.[y or ti,gns Pn,a and is pro.=.-tec un:1e• slate and federal ropynght Ewa An,use of 01" I alllS'orl. other :h"dlret! ;'—'ness —th Monti a plu`."lh_x!;—at—perrvssi,:•+sha:l ionSt,!nl, ; VICINITY MAP -ti� ,: c ,: ,r 2.,grecmrl•l Ir.p.:cl,asc 0-0-arlr:orl...,nd f i L the d[-+lyn Ilrala st•n pr:I!S(ol:yr_kh:I ,Tlllr f 17- lh,lnter 5 FIRST SCREEN E tea. ,; Wtle�FnS"ucep WALL SECTION TO BE MOVED r K S Underwriters °.► -° BACK TO j 3 Laboratories Inc.w 56'0" �.• ra.,.._. .p t PARKING CURB f 51 :,r;, 3a N..aa . Fre. ao ° �� ° CITY OF ARLINGTON FOR VISIBILITY t W j b R• BUILDING DEPARTMENT 25'VISI nY ' v INTERNAT ONAI SIGN ASSOCIATION GAYTEWAY BUSINESS G u PARK 20015 67TH AVE. NE° APPROVED AR INGTON WA 98223 a IVORTHWESTSIGN COUNCIL �, • DA•� BY 0 p 25'VISIBILITY v C: ' ° — — m NO CHANGES AUTHORIZED 3 Baat"n,hAun,rol UNLESS APPROVED BY THE >, ^° BUILDING INSPECTOR ti .aa hr.n••,a „NiiM C'ny V^tl Sa,mQ n4 fF.t•nV � 68aFabicalor4° k"r01'rapme° :—"° SITE PLAN ° v Q SCALE t =120 Received kF..af . JOB COPY C t'F2:11'JC�I(lhI(FA!'�%'A!a'AoAKAW IS f-,Pf I,NiCFXCL.;Snt.11�t1+ ('Ii,s.)'Ik;,A`1GIti.,,�%I',nVl'.)71SCIN,�- ,L JUN 0 8 2020 �)D 2-2I41 ILLUMINATED MONUMENT SIGN SIGNS PLUS 766 Marine Drive Bellingham.WA 98275 Phone 360.671,7105 9'4" signsplusnw.com 81-0" 7'-0" 101, G'OvItmay Bkssmos.Pwk SIGN GRAPHICS AREA 03;24F.1020 75112"X 16"=8.4 SO.FT. Ken Dfrnm!. (up 12 GAYTE 06702/2020 BUSINESS PARK 5 ClIeW Approval WAY ul) 0 MAIN ENTRANCE Prq—MZL App—al 20015 67TH AVE NE 7-. of 2- +�2020 Signs I'lus j This --d, is the SIDEVIEWIxoparn o'Signs r,i j is nro,ecrer under C. state ",-I Ild"'i opyngl,'ie,vs Any use or this Ort`­rk "­ than. direct Signs —th0j! F [11"tiS C of,Vr,xhE l ay.T,flk, MONUMENT SIGN SIGN #1 SIGN COLORS MAIN ENTRANCE MONUMENT Underwriters SIGN AREA------- 8.40 SO. FT Laboratories Inc., SIGN STRUCT ------ 64 SO. FT. IS I DESCRIPTION: FABRICATE AND INSTALL ONE(1)S/S CENTER IDENTIFICATION WHITE ACRYLIC LUMENS --------- 185 PER SO.FT MONUMENT SIGN W/LED ILLUMINATED CENTER ID PANELS AND NON-ILLUMINATED "MAIN ENTRANCE"AND ADDRESS PANELS.BRICK BASE TO MATCH CENTER AND M GAYTEWAY COLUMN WRAPS, ■ MP GREY 0 INTFRNAMNAt SIGN ASSOCIATION BU S I N ESS PAR K TO MATCH BUILDING C_ ITEM NO- ITEM DESCRIPTION NORTHWESTSIGN COUNCIL AAIN ENTRANCE MP I BASE PANEL W/BLURIGREY BRICK TO LT.GREY MATCH BUILDING 2 ILLUMINATED SIGN PANEL W/LED MODULES 3 1/2"WHITE ACRYLIC PUSH-THRU LETTERS MP DK,GREY 4 COLUMN WRAPS ■ TO MATCH BUILDING 5 ALUMINUM SQ.TUBE COLUMN ACCENT BARS SIMULATION OF 6 NON-ILLUMINATED MAIN ENTRANCE&ADDRESS PANELS BLUR/GREY 9 ILLUMINATED SIGN BRICK 12 PRO[i'(,W)1,14 FJ�`Af­"AJkiC/NW ILLUMINATED MONUMENT SIGN #2 I SIGNS PLUS 766 Marine Drive Bellingham,WA 982Z.', Phone 360.671.7105 9'-4R 1'4" slgnsplusnw.com 81-0« 1'-0« - 7'-0« 10« Gavlev,�iv BiiLmes�Pork SIGN GRAPHICS AREA 0122412020 75112"X 16"=8.4 SQ.FT. Ken Dennis lap -- 2 zGAYTE - 3 04:30.2020 v_r_ BUSINESS i- PARK O WAY V_ O AN1�Val ' in ZD r T NORTH p,�,� r AM—al � w P94— 106 20015 67TH AVE M S' .12020 Signs Plus Thr ar.t ,Ic is the SIDE VIEW G N propeu) or pi" rad i_ arorected uncle• C' sracr-"nd tedera: pY R G thi c vri hl Batt 4c use el .Y � .artavnrk : ei ....r. riurcl ;,.i ones+ st,lh �ie;ns u Plus v.-ItIu-'t;v¢te, per--vs=.irn.shall c„xnl,r.• 1= .vre rl.. e.rd I le C1cwIC p'-r�,5n;1 pe UF,Capv,�e,t i�lt'�T,11, 0 1?97 l Il a(]I Pr 4 MONUMENT SIGN SIGN #2 SIGN COLORS SIGN AREA------- 8.4o so. FT. NORTH ENTRANCE MONUMENT O Underwriters Laboratories Inc., SIGN STRUCT ------ 54 SO. FT. DESCRIPTION: FABRICATE AND INSTALL ONE(1)SIS CENTER IDENTIFICATION WHITE ACRYLIC LUMENS --------- 186 PER SO. FT MONUMENT SIGN W1 LED ILLUMINATED CENTER ID PANELS AND NON-ILLUMINATED fu L � "MAIN ENTRANCE"AND ADDRESS PANELS,BRICK BASE TO MATCH CENTERAND o Ike GAYTEWAY COLUMN WRAPS. ■ MP GREY INTERNATIONAL SIGN ASSOCIATION TO MATCH BUILDING ITEM NO. ITEM DESCRIPTION _ x NORT�SIGN COUNCIL NORTH ENTRANCE ' 1 BASE PANEL WI BLURIGREY BRICK MP LT.GREY TO MATCH BUILDING 2 ILLUMINATED SIGN PANEL Wl LED MODULES `, > 3 112"WHITE ACRYLIC PUSH-THRU LETTERS MP DK,GREY 4 COLUMN WRAPS TO MATCH BUILDING 5 ALUMINUM SQ.TUBE COLUMN ACCENT BARS SIMULATION OF 6 NON-ILLUMINATED MAIN ENTRANCE&ADDRESS PANELS BLUR/GREY o BRICK ILLUMINATED SIGN _o C � 1Rg11 -DLLSf,i,':. N�111„lE�'Ri111;1. :Hv'Kfr•„AF'b,JRKANCIIFCHf.USL:Ekial;511'LLYr :F Ii3LFlh':ANC�k(WL, EUN;` 7'DEEP CAISSON FOOTINGS__ 5"DEEP SIGN CABINETS DECORATIVE., _END COLUMNS PLAN VIEW SIGNS PLUS �� — � — W11"SQ.TUBE — / SCALE: 112"= 1' ALUMINUM FRAME I 766 Marine Drive — 1 Rellingham.WA 98225 i 2"X 2"X.187"STEEL BRICK VENEER Phone 360.671 7165 ANGLEFRAME slgnsplusow.com 9.4" 8'-0" 1'-8" Gavlew'ay Bustnesa Pafk 04-3 012 0 2 0 7i-Orr Ken Dennis SIGN STRUCTURE AREA lap 100"X 72"=54 SO.FT. (3)5"X 112"THRU BOLTS TO STEEL POLES as noted j ELECTRICAL -� TOP CABINET os-o2.zozo DISCONNECT LED ILLUMINATED SWITCH —7F jWI 112"PUSH-THRU II�� EDGE-LIT PLEX LETTERS U n •ing ❑o„nal w•r DECORATIVE / /J END COLUMNS ApprovA Wif 1"SQ.TUBE ALUMINUM FRAMES Apprwa MIDDLE 8r BOTTOM CABINETS NON-ILLUMINATED W1112"PLEX LETTERS FLUSH MOUNTED t4020 Signs Plus I This artwork is the _ - property of Signs Pms and is protected tmd, state and federal copyrignt iati s Any use of this a,t,,.rk orher than direct busmess .,uh S�Qns ' SIDE VIEW v Plus a —e t to permission shall Con sn tote C your agreement to purchase this,a!Iworl.,and 2 the design proposed per JS lopvngh'Lars Title 4"X 4"X.188"HSS SQ-TUBE z '"Chapter s 12'-6" w Y N E O Underwriters Laboratories Inc._ C FRONT ELEVATION SIDE VIEW E E SCALE: 112'= 1' � SCALE. 112'=1' C INNnRNNAAnoNNAL SIGN ASSOCIATION f' 24"DIA.X 7'DEEP CONCRETE N NORTHWESTSHMN COUNCIL v CAISSON FOOTINGS C C m yti N ti u w u U C N f i.VY CAISSON FOOTING CHART REQUIRED F00.TING SIZE FOR AREA AND HEIGHT OF SIGN so 45 28 I--L-gj 40 26 07 18K 27 32 12 35 20 IA. a 22 0 30 - 23 Lu 23 IN, 24 x 7 20 is IN 3 10 El Jo 7 W 1�6— -766—� go 90 100 110 120 130 140 150 160 170 180 lm 200 210 220 230 240 250 260 270 280 290 300 4 5 d A x B,AREA OF SIGN(SQUARE FEET) 12/07/=7 wAss NW MSO-WA 04-1 DA7F 12/07/20V SCHNEIDER ., coo 2.. lz STRUCTURAL ENGINEERS th NWSC-WASHINGTON REVISIONS .;� SIGN STANDARDS FOR 2015 EDITION OF THE WASHINGTON STATE BUILDING CODE 61 VF 0 89295 5OM7MW CrA"ENIB NLfllbw:115451 ';'A L ='—WE U IVAL COLUMN FINIS�11ED CAISSON FOOTINGS GLADE NOTES D 1'-6" DIA. x 4'-0" DEEP 16� 3'-0" DA. x 10'-0" DEEP 1. POLES AND FOOTINGS AR:, DESIGNED FOR SINGLE AND DOUBLE FACED SIGNS. „•f 2, ALL INTERSECTION POINTS ON THE CHARTS MUST USE THE LINE ABOVE AND 70 'fHE I DIA. x 4'--0" DEEP 17 3'--6" DIA. x 10'--•0" DEEP "'�.� .��, RIGHT UNLESS THL POINT FALLS ON A LINE. -FTG, 3. SEE SHEET NViSC—WASHINGTON 04-0 FOR SPECIFICATIONS AND DESIGN CRITERIA. 1 —6' DIA. x 5'-0" DEEP (1D 3'-0" DIA. x 11'-0' DEEP 40 2'-0" DIA. x 5' 0" DEEP19 3'-6" DIA. x 11'-0" DEEP d 1'-6" DIA. x 6'--0" DFFP 20 4'--0" D.A. x 11'--O" DEEP 61 2'-0' D:A. x 6'-0" DEEP 21 3'-0" DIA, x 12'-0" DE=P 1'-6" D:A. x 7'-0" DEEP 22 3'-6" DIA. x 12'-0" DEEP ; '' ( 8 '-0" DIA. x T 0" DEEP 23 4'-0" DIA. x 12'-0" DEEP 8" f MAX. h a 2'--6" DIA. x 7'-0" DFEP 24 S-6" DIA. x 13'-•0" DEEP EXAMPLE 10 2' 0" pIA. x 8'-0" DEEP 25 4'-0" DIA. x 13'-0" DEEP. GIVEN: SIGN DIMENSIONS OF 10'-0", E = 14'-6", AND H = 36'--0" (HEIGHT -I0 CENI'ER OF SIGN). 11 2'-6" DIA. x 8'-0" DEEP 2�6 4'-6" DIA. x 13'—O" DEEP 12 3'-0" DIA. x 8'--0" DEEP 27 4'-0" DIA. x 14'-0" DEEP �lISSON FOOTING CHART: FIND A x B = 145 S.F. AND DRAW A VERTICAL LINE UP TO INTERSECT A HORIZONTAL LINE DRAWN FROM H = 36'. 13 2'-6" D.A. x 9'-0" DEEP 28 4'-6" DIA. x 14'-0" DEEP USE THE LINE ABOVE. AND TO THE RIGHT OF THE INTERSECTI N INT AND PICK 14 3'-0" D;A, x 9'-0" D7 P 29 5'-0" DIA. x 14'-0" DEEP OUT A # � CAISSON. GO TO CAISSON F007INGS LIST FOR C�SSONS AND SEE THAT ;HIS IS A 3'• 6"x13'--0" -)FFP CAISSON. , (1) 2'-6" D:A. x 10'--0" DEEP 30 4'-6" DIA, x 15'-0" DEEP i .1 31 5'-0" DIA, x 15'-0" DEEP 32 5'-6" DIA. x 15'-0" DEEP 33 6'-0" DIA. x 1 --0" DEEP k a. 12/07/2017 IvnSHEn s�•�'rd [DATE WA0" -- SCHNEfDER �cl071 STRUCTURAL ENGINEERS cn NWSC-WASHINGTON r,c��eoron�ioH�o ornurruRu_,nHovnr,cry SIGN STANDARDS FOR 2015 EDITION OF THE WASHINGTON STATE BUILDING CODE �SI°"s ��« � •• -- G°T 39295 �Pialact Nuymbw::1111554SI �s �!?A L M+�MwI�YM�1�101nL'1/L'If1im10fMf7�R1+PNra�A�nK,V,MM_ S�O��, Y All 6A j SECTION MODULUS CHART (Zx) REQUIRED SECTION MODULUS FOR AREA AND HEIGHT OF SIGN 50 45 — 175 144 209 0 E-16 LL JE U 0 30 w 0 53 ,F37] 25 3 ",E2O 20 0 10 Du uu lu au vu TUU —110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 ,290 300 Er H �201 u[;A A x B.AREA OF SIGN(SQUARE FEET) r. 12JO712DV 0 yl. S MC-WA 0+-2 1-3 DATE SCHNEIDER NWSC-WASHINGTON . 12/07/= STRUCTURAL EN'GINEERS REVISIONS SIGN STANDARDS FOR 2015 EDITION OF THE WASHINGTON STATE WILDING CODE T�A-I M I"-o— 295 MO7 COMMWM PKJw Mumbw I 1w, &RA L SECTION MODULUS_-G QUP5 B THE FOLLOWING ARE THE MOST COMMONLY USED MEMBERS, GROUPED ACCORDING TO THEIR SECTION MODULUS LINE ON THE CHART. SYM30LS; Zx = SECTION MODULUS; HSS = STRUCTURAL TUBE; A . DIA. STD. = STANDARD PIPE SECTION Zx = 0.5 Zx = 1.0 Zx = 2.0 Zx 3.O � r 2" DIA. STD. 2 112" DIA, StD, 3" DIA. 51D. 3 A. STD. HSS 2" x 2" x 3/16" I SS 2 1/2" x 2 1/2" x 3/16" HSS 3" x 3" x 3/16" HSS 3 1/2" x 3 1/2" x 3/16" USE 4X4X3/16" 1 1 TWO POLES MAY BE USED FOR A SINGLE SIGN. IF THIS Zx 4 IS THE CASE, USE HALF OF Zx 6 Zx 10 _ Zx - 20 H D. ' THE TOTAL SIGN AREA WHEN 4" DIA. ST 5" DIA. STD. 6" DIA. STD. V 8" DIA STD. � ; USING THE CHARTS. HSS 4" x 4" x 3/15" HSS 4" x 4" x 5/16" HSS 5" x 5" x 5/16" HSS 6" x 6" x 1/2_" HSS 5" x x 3,/16" HSS 6" x 6" x 3/16" HSS 7" x 7" x 5/'6" d Zx = 37_ Zx = 53 Zx = 69 Zx = 91 10" DIA. STD- 12" DIA. STD. 14" DIA. STD. _ 16" DIA. ST-3. b HSS 8" x 8" x 3/8" HSS 12" x 12" x 1/4" HSS 12" x 12" x 5/16" HSS 14" x 14" x 5/16" HSS 10" X 10" X 1/4" Zx =_116 _ Zx = 144 Zx = 175 Zx = 209 r 18" DIA. STD. 20" DIA. STD. 22" DIA. STD. 24" DIA. STD. HSS 14" x 14" x 3/8" HSS 14" x 14" x 1/2" HSS 14" x 14" x 5/8" HSS 16" x 16" x 1/2" )ALE HSS 16" x 16" x 5/16" HSS 1:6" x 16" x 3/8" HSS 16" x 16" x 1/2" GIVEN: A 10'-0", B = 14'-6", H = 36'-0" (HEIGHT TO CENTER OF SIGN). >QN MODULUS QUART. FIND A. x B = 145 S.F. AND DRAW A VERTICAL LINE UP 5x = 246 Sx = 286 Sx = 324 TO INTERSECT A HORIZONTAL LINE DRAWN FROM H = 36'. 26" DIA. STD. 28" DIA. STD. 30" DIA. STD. THIS INTERSECIION POINT FALLS BELOW Zx = 91. USE TT IL LINE ABOVE AND TO H55 16" x i6" x 5/8" THE RIGHT OF THE INTERSECTION POINT. THEREFORE USE Zx = 91. GO TO SECTION MODULUS L'.ST FOR Zx = 91 AND PICK A POLE SIZE OF 16" DIA. STD. PIPE OR 14" x 14" x 5/16" STRUCTURAL TUBE. r , 12/07/2OT7 H• SCI� 0 L�f MC-WA04-3 DATESCHNE[DER 1210712W NWSC-WASHINGTON STRUCTURAL ENGINEERS N a � FIRl.1 OF_LnL`ATON l O bTg1A:T.Rg4,N NovgTON SIGN STANDARDS FOR 2015 EDITION OF THE WASHINGTON STATE BUILDING CODE REMS IONS ue� 39295 G�.4p ,w 18/D7/17 Project Nu+dn.^.115451 �?S AL 1 17235 N. 75th Ave., Suite D145 • Glendale,AZ 85308 ' Ph: 888-856-6972 • Fax:602-789-9126 info@nwsigncouncil.org --------------------------------------------------------------- ------------------------- May 4, 2020 City of Arlington Attn: Community Development To whom it may concern: This letter shall serve as verification that Signs Plus, Inc. is authorized to use the engineering standards of the Northwest Sign Council for the following project: Gayteway Business Park 20015 67th Ave NE Arlington, WA 98223 Signs Plus, Inc. is a member in good standing with the Northwest Sign Council and has been trained in the proper use of the Northwest Sign Council engineering standards. Please call me if you have any questions. Respectfully, 4A�- I — Patricia King Executive Director C: Signs Plus, Inc. www . nwsigncouncil . org NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY p APPROVED `` PERMIT#: -7��� A ,PM DATE: I i.M i ) JOB ADDRESS: �((� J_ l �� at- LOT it: PROJECT: TYPE OF INSPECTION: 1 OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THEACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE CIVIL -1 BUILDING 7 < O PLANNING o c CITY OF ARLINGTON NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL Cl CORRECTIONS REQUIRED ❑ DO NOT OCCUPY 'APPROVED PERMIT#: O AM A PM DATE: i°` JOB ADDRESS: �' '1 ` : �l �� U e LOT#: PROJECT: 1'.(iA -L�)�u i; 1• U1 l� �,' ( L� ���1v; TYPE OF INSPECTION: �',i A\ OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN-BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE. O PLANNING O CIVIL 7 BUILDING CITY OF ARLINGTON CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center:360403-3551 BUILDING PERMIT 19927 67th Avenue NE Permit#:3147 Permit Expiration Date: 10/31/2020 Parcel#: 31051400200700 Valuation: 16074.00 OWNER APPLICANT CONTRACTOR Gayteway Business Park,LLC Signs Plus,Inc Signs Plus P.O.Box 1727 766 Marine Drive 766 Marine Drive Bellevue,WA 98009 Bellingham,WA 98225 Bellingham,WA 98225 360-393-1265 360-671-7165 LIC:SIGNSPT952I.W FXP:06/162021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC. #: EX1': LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Sign CODE YEAR: 2015 STOR-WS: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Cade or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELAI'ING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRCI 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on ksallesx cturn form and coded City of Arlington#3101. C v� I�C K✓U'r S 20 `7 ZL7 Signature Print Name Date Released By ) e CONDITIONS ADHERE TO APPROVED PLANS. JOB COPY SHALL BE ONSITE FOR INSTALLATION AN INSPECTIONS.SIGN CH A I f NTIT RF f nT~ATT.TI WITHIN TIP ('TTV'C ¢f('F"T VTCTPIT TTV e ar•e c AT nrn A nr rriri runt ML'--)IPAL CODE 20.48.042.CALL FOR INSPE("�NS. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVEK'5 WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. P=bKT FM Date Description Fee Amount 07/06/2020 Processing/Technology Fee $25.00 07/06/2020 State Surcharge-Commercial $25.00 07/06/2020 Signs $418.00 Total Due: $468.00 Total Payment: $0.00 Balance Due: $468.00 Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon i CITY OF ARLINGTON �\ % 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 19927 67th Avenue NE Permit#: 3147 Permit Expiration Date: 10/31/2020 Parcel#: 31051400200700 Valuation: 16074.00 OWNER APPLICANT CONTRACTOR Gayteway Business Park,LLC Signs Plus,Inc Signs Plus P.O. Box 1727 766 Marine Drive 766 Marine Drive Bellevue,WA 98009 Bellingham,WA 98225 Bellingham,WA 98225 360-393-1265 360-671-7165 LIC:SIGNSPI952LW EXP:06/16/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Sign CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law, or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI I0/IRCI10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. `7 Z� Signature Print Name Date Rcicased By e CONDITIONS ADHERE TO APPROVED PLANS. JOB COPY SHALL BE ONSITE FOR INSTALLATION AN INSPECTIONS. SIGN SHALL NOT BE LOCATED WITHIN THE CITY'S SIGHT VISIBILITY AREAS AT INTERSECTIONS PER ARLINGTON MUNICIPAL CODE 20.48.042. CALL FOR INSPECTIONS. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PRRMff FEES Date Description Fee Amount 07/06/2020 Processing/Technology Fee $25.00 07/06/2020 State Surcharge-Commercial $25.00 07/06/2020 Signs $418.00 Total Due: $468.00 Total Payment: $0.00 Balance Due: $468.00 CALL FM DMPECTKM Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon NW 1.4 AND SW 1A OF SEC 14.T31N R5E W W CITY OF ARLINGTON.ShOHOM,SH COUNTY,WA 0,of, �•r..tw I' z H 2 K 1�1a2 to Y I C lip I BUS I N ESS PARK BUSINESS PAR MAIN ENTPANCE �. Nf Q k 20015 67TH AVE NE oc MONUMENT SIGN V T NEWNEW STREET NEW STREET �M L Q , R° uG ON LIGHT ON EX POLE NEW DRNFNAY LIGHT ON G EX POLE HT I NEW STREET w PER DTL 3,C1 4 REMOVE EX L047 r0.1KIA 6 EX OWING O'SETI t-J Wk UW ROAMTREE(TYP) TO w'U trw TREE(TYP) 6TTH AVENUE NEmvlww _ - -- - - kF CHIMP 1 - r trstr t •- j f - - I vtY U a � a J NYMALIgm CL coo W m N c I-1 Z m o I °D i J RELOCATE EX. Jft q RELOCATE EX I NEW PEDESTRIAN I II BOLLARDS TO END giscomw ftdba.-Otis Q CO � I BCILARDS TO END NEW PEDESTRIAN NEW STREET LIGHT REMOVE NFN STREET UGHT REMOVE EX METERS _SCREEN OF E/1G1 DRIVEWAY C) OF EACH DRNEWA LIGHT REMOVE EX METER 6Jr�+t ud LALli r ITYPI PATCH EX ASPHALT Y/4 XB,� EX VALVE PHALALT PATCH BACK CURB DUE TO >_ Ez ASPHALT TRAIL TO NEW FQE HYDRANT TRAIL(FULL WIDTHI } V TIUT1rs/we 5 ++ s ~ ` SHUT SCREEN WALL TO BE SAIMCUT 6 PATCHED PATCH EX ASPHALT (FULL W1D1H1 STREET LIOFiT LOCATION. Q BACX OF CURB TO ALLOW TRAM IFILL wlon+l 'area z FOR Sla VISOUTY R BUILDING H _ BREAK ON SCIORATION ZR WALL DETERMI7ED BY CITY) BUILDING'C' ' 67TH AVE \ CONSTRUCTION DRAWING APPROVAL .REVISIONS "it m co oTon a Irc I'u 24M w ->� = C 1 . 2A Permit#: 3147 Permit Date: 05/04/20 Permit Type: SIGN INSTALLATION Project Name: Gayteway Business Park Bldg. C Applicant Name: Signs Plus, Inc Applicant Address: 766 Marine Drive Applicant, City, State, Zip: Bellingham,WA 98225 Contact: Kenneth E Dennis Phone: 360-393-1265 Email: ken@signsplusnw.com Scope of Work: New monument sign Valuation: 16074.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 07/09/2020 Permit Expires: 01/05/2021 Form Permit Type: Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 399 Other way Park,31051400200700 19927 67TH AVE NE Ga ,LLC Business Miscellaneous Manufacturing NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License# SIGNS PLUS INC ROYCE 360-671-7165 766 MARINE DR CONSTRUCTION COA 602 475 651 SIEVING CONTRACTOR SIGNS PLUS INC ROYCE 360-671-7165 766 MARINE DR CONSTRUCTION LABOR& SIGNSPI952LW SIEVING CONTRACTOR INDUSTRIES Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 12/04/2020 500.SIGN FINAL complete 12/04/2020 12/04/2020 BUILDING Approved 11/24/2020 R20.SFR/DUPLEX Sign post concrete pour 11/24/2020 11/24/2020 BUILDING Approved FINAL Plan Reviews Date Review Type Description Assigned To Review Status 06/10/2020 SIGN INSTALLATION BUILDING 06/10/2020 SIGN INSTALLATION Sign#2 location must be shown to meet sight triangle Josh Grandlienard requirements 06/10/2020 SIGN INSTALLATION Nova Heaton Fees Fee Description Notes Amount Processing/Technology $25.00 State Surcharge-Commercial Commercial Only $25.00 Signs Valuation Permit Fee Only $418.00 Total $468.00 Attached Letters Date Letter Description 05/04/2020 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 07/07/2020 Kim Jeppson 81193492 $468.00 Outstanding Balance $0.00 Notes Date Note Created By: 07/09/2020 Emailed the permit for signature. Kristin Foster 07/06/2020 KO approved 7/2/2020 Kristin Foster 07/06/2020 Sign#2 location must be shown to meet sight triangle requirements Kristin Foster SIGN SHALL NOT BE LOCATED WITHIN THE CITY'S SIGHT VISIBILITY AREAS AT 07/06/2020 INTERSECTIONS PER ARLINGTON MUNICIPAL CODE 20.48.042.Condition to apply to Kristin Foster permit after conversation with Josh for clarification on comments. 06/11/2020 Received a site plan with sign and utility locations. Kristin Foster 06/10/2020 Utility locations? Kristin Foster Uploaded Files Date File Name 10/11/2021 9865779-3147 IC 12.4.2020.pdf 10/11/2021 9865780-3147 IC 11.24.202.pdf 07/10/2020 6957255-3147 Issued Permit.pdf 06/11/2020 6808496-3220 Site Plan with Utilities.pdf 06/10/2020 6799637-3147 6-5-2020 Application.pdf 06/10/2020 6799546-3147 Engineer Standards Authorization.pdf 06/10/2020 6799547-3147 6-5-2020 Plans.pdf Date: 04/02/2026 Permit#: 3147 Permit Date: 05/04/2020 Review Date: 06/10/2020 Permit Type: SIGN INSTALLATION Review Type: SIGN INSTALLATION Target Date: 06/24/2020 Scheduled Time: 00:00 Completed Date: 06/10/2020 Description: Sign#2 location must be shown to meet sight triangle requirements Review Status: Assigned To: Josh Grandlienard Time In: 00:00 Time Out: 00:00 Hours: 0.0 Property Information Parcel#: 31051400200700 Gayteway Business Park, LLC Gayteway Business Park, LLC P.O. Box 1727 19927 67TH AVE NE Bellevue, WA 98009 Zoning: 399 Other Miscellaneous Manufacturing NECLot: Block: