Loading...
HomeMy WebLinkAbout18321 31ST AVE NE, BLDG C_BLD3435_2026 Y °•� FIRE SPRINKLER ' PERMIT APPLICATION INC;` Department of Community&Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF COMPLETE AND SCALED PLANS, TWO (2) SETS OF HYDRAULIC CALCULATIONS, TWO (2) SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE SPRINKLER PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION. Type of Permit: ® New Fire Sprinkler ❑ Fire Sprinkler Add/Alt ❑ Underground Fire Line Project Address:18321 31 st Ave NE-Arlington WA 98223 BLDG C Parcel ID#: Project Valuation: 38,400.00 Number of Heads: 205 Building Area(Sq Ft): Owner: The Landinq at Smoking Pointe. LLC Phone Number: 253-332-4017 Address: 16000 Christensen Road, Suite 150 City. Tukwila State: WA Zip Code: 98188 Contact Person: Robert Rex Phone Number: 805-368-9466 Cell Phone: Email: robert mttholdings.com Address: 18000 Christensen Road, Sijite 15n City. Tukwila State: W— Zip Code: 98188 Contractor: Nor-Tech Fire Fire Protection, Inc Phone Number: 425-898-9111 Address: 20030 NE Novelty Hill Rd. Box- B City: Redmond State: CIA— Zip Code: 98053 Contractor's License Number: NORTEFP051 P6 Expiration: 10/26/2021 Contact Person: Dean Olsen Email: dean(anortechfire_com I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- describe p y will be in accor ance with the laws, rules and regulation of the State of Washington. September 10. 2020 Applicants Signature Date Dean Olsen Print Applicants Name FOR STAFF USE ONLY _ e ce i ved y ,7 SEP 14 2020 Permit# Acce ed By Amount Received Receipt# Date Received WEB Forms—131 Page 1 of 1 6/16LP G1�Y °� FIRE SPRINKLER • PERMIT APPLICATION ��lINGt�� Department of Community&Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF COMPLETE AND SCALED PLANS, TWO (2) SETS OF HYDRAULIC CALCULATIONS, TWO (2) SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE SPRINKLER PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION. Type of Permit: ® New Fire Sprinkler ❑ Fire Sprinkler Add/Alt ❑ Underground Fire Line Project Address:18321 31 st Ave NE -Arlington, WA 98223 BLDG C Parcel ID#: Project Valuation: 38,400.00 Number of Heads: 205 Building Area (Scl Ft): Owner: The Landing at Smoking Pointe, LLC Phone Number: 253-332-4017 Address: 16000 Christensen Road, Suite 150 City: Tukwila State: WA Zip Code: 98188 Contact Person: Robert Rex Phone Number: 805-368-9466 Cell Phone: Email: rbert mttholdings_com Address: 16nOO Christensen Road, SiiitP 1.90 City: Tukwila State: WA Zip Code: 98188 Contractor: Nor-Tech Fire Protection, Inc. Phone Number: 425-898-9111 Address: 20030 NE Novelty Hill Rd. Box- B City: Redmond State: WA Zip Code: 98053 Contractor's License Number: NORTEFP051 P6 Expiration: 10/26/2021 Contact Person: Dean Olsen Email: dean nortechfire.com I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accordance with the laws, rules and regulation of the State of Washington. September 10, 2020 Applicants Signature Date Dean Olsen Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received WEB Forms—131 Page 1 of 1 6/16LP ES-A-2000B-FP Jk Series 2000B-FP A M E S Double Check Valve Assemblies FIRE&WATERWORKS Sizes: 1" —2" (25 —50mm) Features • Ease of maintenance with only one cover _ • Top entry t 2000B-FP • Replaceable seats and seat discs • Modular construction • Compact design • 1"—2" (25—50mm)Cast bronze body construction • Low pressure drop � �- • No special tools required • Gear operated, slow close shutoffs • Pre-wired tamper switch(2)per Series 2000B-FP Double Check Valve Assemblies shall be installed at referenced cross- shutoff connections to prevent the backflow of polluted water into the potable water supply.Only those cross-connections identified by local inspection authorities as non-health hazard shall be allowed the use of an approved double check valve assembly. Pressure — Temperature Check with local authority having jurisdiction regarding vertical orientation,frequency of Temperature Range: 33°F—140°F testing or other installation requirements. (0.5°C—60°C) These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foundation for Cross-Connection Control and Hydraulic Research at the Maximum Working Pressure: 175psi University of Southern California. (12.1 bar) Specifications Standards A Double Check Valve Assembly shall be installed at each noted location.The assembly shall consist of two positive seating check modules with captured springs and rubber seat AWWA Std. C510, IAPMO PS31 discs.The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts.The assembly shall also include two resilient seated gear operated slow close isolation valves and four resilient seated test cocks.The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510.Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California.Assembly shall be an Ames Company Series 2000B-FP. Approvals GASSIFj�o The information contained herein is not intend- H55EQ C V� US ed to replace the full product installation and us safety information available or the experience 1015 B64.5 1"-2" of a trained product installer.You are required to thoroughly read all installation instructions Approved by the Foundation for Cross-Connection Control and Hydraulic Research at and product safety information before begin- the University of Southern California. ning the installation of this product. Horizontal approval on all sizes. Inh hinmo (`nntrartnr Cont.Job Location Approval Engineer Contractor's P.O. No. Approval Representative Ames Fire&Waterworks product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measurements,please contact Ames Fire&Waterworks Technical Service.Ames Fire&Waterworks reserves the right to change or modify product design,construction,specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire&Waterworks products previously or subsequently sold. Dimensions — Weights --------------- E ----------------1 rM C ¢il ail H F D ----------------------------A------------------------------------ ----------------------------- I ------------------------------------- MODEL SIZE DIMENSIONS A B C D E F G H I in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 2000B-FP 1 25 13'/4 337 41/2 114 31/2 89 1 25 71/2 191 53/4 146 21/8 73 27/8 73 14% 365 12.2 5.5 2000E-FP 1'/4 32 15% 397 51/8 136 33/4 95 1% 41 91/2 241 6'/1 6 154 21/8 73 33/6 81 161/2 419 17.3 7.8 2000E-FP 11/2 40 163/8 416 5% 143 4 102 1% 41 9% 248 61/4 159 27/8 73 33/8 86 17 432 19 8.6 200OB-FPI 2 50 1 191A 486 1 61/2 165 1 41/4 108 1 21/4 54 1 13% 340 1 61/2 165 27A 73 35A 92 191/2 495 26.4 12 Strainer sold separately Capacities As compiled from documented Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California lab tests. 'Typical maximum system flow rate(7.5 feet/sec.,2.3 meters/sec.) kPa psi 1" (25mm) kPa psi 1 th" (40mm) y 110 16 * 83 12 J 83 12 rn 69 10 L 69 10 55 8 0 55 8 3 8 J to 41 6 y 41 6 28 4 3 28 4 a 14 2 ui 14 2 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm 0 0 AP IL APO 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 19 38 57 76 95 114 133 152 171 190 209 228 Ipm 0 38 76 114 152 1,90 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 5 7.5 10 15 fps Flow Rate 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 1114" (32mm) kPa psi 2" (50mm) 96 14 * 83 12 w 83 12 N 69 10 o 69 10 _j 55 8 y 55 8 Iv 41 6 41 6 N 28 4 ai 28 4 ayi 14 2 li 14 2 a 0 0 0 25 50 75 100 125 150 175 200 gpm 0 0 OP 0 95 190 285 380 475 570 665 760 Ipm lip 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 5 7.5 10 15 fps 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 1.5 2.3 3.0 4.6 mps 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate Flow Rate EVITOMM Inquire with governing authorities for local installation requirements A A M E S FIRE&WATERWORKS A Watts Water Technologies Company USA:Backflow Tel:(978)689-6066•Fax:(978)975-8350•AmesFireWater.com USA:Control Valves Tel:(713)943-0688•Fax:(713)944-9445•AmesFireWater.com Canada: Tel:(905)332-4090•Fax:(905)332-7068•AmesFireWater.ca Latin America: Tel:(52)81-1001-8600•Fax:(52)81-8000-7091 •AmesFireWater.com ES-A-2000B-FP 1536 0 2015 Ames Fire&Waterworks CO® Worldwide www.tyco-fire.com Contacts Model RM-1 Riser Manifold Commercial and Residential General Optional Pressure Relief Kits feature a 175 psi pressure relief valve and trim Description components for convenient integration into commercial and residential riser The TYCO commercial and residential manifold assemblies. Model RM-1 Riser Manifold provide The pressure relief valve, installed in the necessary waterflow alarm, pres- manifold assemblies above the nor- sure gauge, alarm test orifice, drain, mally closed test and drain or drain and sight glass equipment in a single valve, automatically bleeds system assembly for use in NFPA 13 com- pressure exceeding 175 psi through a mercial sprinkler systems and in NFPA flexible hose connected to the mani- D 13D/13R residential sprinkler systems fold drain outlet(Ref. Figure 5), reduc- as follows: ing system pressure to 175 psi. NFPA 13* • 1-1/2 in. (DN40) M \, Male Thread x Female Thread The Model RM-1 Riser Manifolds • 2 in.-6 in. (DN50—DN150) described herein must be installed Groove x Groove and maintained in compliance with this document, as well as with the applica- NFPA 13D ble standards of the NATIONAL FIRE • 1 in. (DN25) PROTECTION ASSOCIATION (NFPA), „ Female Thread x Female Thread in addition to the standards of any other NFPA 13R authorities having jurisdiction. Failure • 1-1/2 in. (DN40) to do so may impair the performance r� Male Thread x Female Thread of these devices. • 2 in. (DN50) The owner is responsible for main- _ Groove x Groove taining their fire protection system and devices in proper operating con- Although the Riser Manifold described in this techni- dition. Contact the installing contrac- cal data sheet is intended for NFPA 13 sprinkler sys- tems,it may be used for NFPA 13D or 13R residential p y sprinkler systems,where a test orifice of 2.8K or 4.2K questions. is acceptable. The variety of sizes and grooved end Technical connections allow cost effective and easy transition to check valves,control Data valves, and system piping. The Model RM-1 Riser Manifolds may be installed Approvals either horizontally (flow switch on top) UL and ULC Listed or vertically(flow going up)orientation, FM Approved for both single sprinkler rises and floor Listed by California State Fire Marshall control in high-rises. Maximum Working Pressure 300 psi(20,7 bar) Test Orifice 1 in.-3 in.(DN25-DN80)Manifolds:2.8K 4in.-6 in.(DN100-DN150)Manifolds:4.2K Finish Red Painted IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Page 1 of 8 AUGUST 2018 TFP963 TFP963 Page 2 of 8 Nominal NO DESCRIPTION P/N Nominal End Nominal Dimensions Drain 1 300 psi/2000 kPa Inches Size Water Pressure Gauge..90050001 Riser Connections Size (mm) Inches 2 Test and Drain Valve, Inches (DN) Model TD-1: (DN) 3 Inch Inlet Outlet A B C D E F G H (DN4-DN40-DN8N80) 1-1/2 Thread Thread 10 15-1/2 2-1/4 5-5/8 8-3/8 15 4-3/8 1-1/4 Size Manifolds, (40) MNPT FNPT (254) (394) (57) (143) (213) (381) (111) (32) 1-1/4",2.8KOrifice.....A61G0420 4-6 Inch 2 Groove Groove 13 18 2-1/16 5-5/8 8-3/8 15-1/4 4-3/8 1-1/4 (DN100-DN150) (50) (330) (457) (53) (143) (213) (388) (111) (32) Size Manifolds, 2",4.2K Orifice........A61 G0601 2-1/2 Groove Groove 13 18-1/16 2-1/16 5-5/8 8-3/8 15-1/4 4-3/8 1-1/4 3 Flow Switch,VSR-M: (65) (330) (460) (53) (143) (213) (388) (111) (32) 1-1/2"(DN40).........91144815 3 13 18-1/16 2-1/16 5-7/8 8-5/8 15-3/4 4-3/8 1-1/4 2"(DN50) ............91144802 (80) Groove Groove (330) (460) (53) (150) (219) (400) (111) (32) 2-1/2"(DN65).........91144825 3"(DN80) ............91144803 4 13 20-1/4 4-1/4 6-3/4 10-3/4 18-3/8 5-3/16 2 4"(DN 100) ...........91144804 (100) Groove Groove (330) (514) (108) (172) (273) (467) (132) (50) 6"(DN150) ...........91144806 6 13 20-1/4 4-1/4 7-3/4 11-3/4 21 6-3/4 2 4 Field Replaceable (150) Groove Groove (330) (514) (108) (197) (300) (533) (172) (50) Retard/Switch.........91144800 OUTLET 1 OPTIONAL PRESSURE ° RELIEF TRIM CONNECTION In, 0 0 3,4 / A B I 2 I OLjwo b 0 /\ O INLET C G H D E F FIGURE 1 MODEL RM-1 COMMERCIAL RISER MANIFOLDS 1-112-6 INCH(DN40—DN150) TFP963 Page 3 of 8 OPTIONAL PRESSURE RELIEF TRIM 1" NPT 1 CONNECTION (FEMALE) NO DESCRIPTION P/N 10" 2 -n 11„ 1 300 psi/2000 kPa Water Pressure Gauge..90050001 (254 mm) O (280 mm) 2 Ball Valve,1"(DN25)....97111603 3 Flow Switch,VSR-M, 1"(DN25) ............91144801 4 Field Replaceable C Retard/Switch.........91144800 2-1/2" 1" (64 mm) NPT DRAIN 3-3/4" (100 mm) 1" NPT 3,4 4-5/8" (FEMALE) (118 mm) 10-1/8" (257 mm) FIGURE 2 MODEL RM-1 RESIDENTIAL RISER MANIFOLD 1 INCH(DN25) OPTIONAL PRESSURE 1 RELIEF T 1 NPT CONNECTION N (FEMALE) 0 13-1/4" (337 mm) NO DESCRIPTION P/N 1011 r- _ 1 300 psi/2000 kPa Water Pressure Gauge..90050001 (254 mm) 2 Ball Valve,1"(DN25)....97111603 2 3 Flow Switch,VSR-M, 1-1/2"(DN40).........91144815 7/16„ 4 Field Replaceable (11 mm) Retard/Switch.........91144800 3-7/8" 3-7/8" 3,4 y (100 mm) 1 (100 mm) 1-1/2" NPT NPT 4-3/4" (MALE) DRAIN (121 mm)~ 11-3/8" (290 mm) FIGURE 3 MODEL RM-1 RESIDENTIAL RISER MANIFOLD 1-112 INCH(DN40) TFP963 Page 4of8 1 2" (GROOVED) OPTIONAL PRESSURE O RELIEF TRIM CONNECTION m 16" r 0 (406 mm) NO DESCRIPTION P/N 13" 41/ 1 300 psi/2000 kPa (330 mm) Water Pressure Gauge..90050001 2 Ball Valve,1"(DN25)....97111603 3 Flow Switch,VSR-M, 2"(DN50) ............91144802 2 4 Field Replaceable Retard/Switch.........91144800 1/2" (13 m3-7/8" 3,4 (100 mm) 1 (105 mm) 2" NPT 5" (GROOVED) DRAIN ~(127 mm)~ _ 11-7/8" _ (300 mm) FIGURE 4 MODEL RM-1 RESIDENTIAL RISER MANIFOLD 2 INCH(DN50) Notes: Step 1. Install the manifold body with Manifold Where applicable pipe thread sealant the flow arrow pointing in the down- Installation is to be applied sparingly. Use of a stream position using threaded con- non-hardening pipe thread sealant is nections and/or listed mechanical TYCO Model RM-1 Riser Manifold recommended. grooved connections, as applicable. must be installed in accordance with Never remove any piping component Step 2. Connect the drain line and on this section. nor correct or modify any piping defi- commercial manifolds set the Model The Model RM-1 Riser Manifold may be ciencies without first depressurizing TD-1 Test and Drain Valve to the OFF installed either horizontally(flow switch and draining the system. position or on residential manifolds on top)or vertically(flow going up).The close the drain valve. Residential Models must inlet of the Riser Manifold may be con- Provisions for an alarm test flow e. Step 3. Refer to Figure 6 for wiring nected directly to a shut-off control made. guidance.All wiring must be performed valve. The alarm test flow is to ae through in accordance with the authority having to or smaller than the smallest orifice orifice having a flow capacity equal jurisdiction and/or the National Electri- sprinkler in the system. One of two cal Code. options can be considered. The first Step 4. Refer to Figure 5 for Optional option is to temporarily install a test Pressure Relief Trim installation. orifice in the outlet of the drain line Step 5. Place the system in service prior to performing the alarm test. The by filling the system with water. When second option is to install an Inspec- filling the system, partially open the tor's Test Connection downstream of control valve to slowly fill the system. the Waterflow Alarm Switch. Filling the system slowly will help avoid damaging the waterflow alarm switch. After the system is fully pressurized, completely open the control valve. Step 6.Secure all supply valves open. TFP963 Page 5of8 Commercial Riser Manifolds Residential Riser Manifolds NO DESCRIPTION P/N NO DESCRIPTION P/N 1 Pressure Relief Valve, 1 Pressure Relief Valve, 175 psi,1/2"NPT..........1001184-01 175 psi,1/2"NPT..........1 001 1 84-01 2 112"x Close Nipple ........1001023-01 MODEL RM-1 2 1/2"x Close Nipple,Qty 2...1001023-01 3 Flexible Hose: COMMERCIAL 3 Flexible Hose,1/2"x 16"....1001266-03 1-1/2-3 Inch(DN40-DN80) RISER MANIFOLD 4 Figure 815 Threaded Size Manifolds, 2 Reducing Tee, 1/2"x 24..................1001266-02 1 1"x 1"x 1/2"NPT.........1001259-07 4-6 Inch(DN100-DN150) \ 5 1"x Close Nipple..........1001025-01 Size Manifolds, 1/2"x 30..................1001266-01 0 4 Figure 323 Reducing Tee, 0 MODEL RM-1 Grooved x NPT Threaded: RESIDENTIAL 1-1/2-3 Inch(DN40-DN80) RISER MANIFOLD Size Manifolds, 2 1-1/4"x 1-1/4"x 1/2 3231305GS 4-6 Inch(DN100-DN150) a Xl Size Manifolds, 2"x 2"x 112.. .............3232005GS5 Figure 577 Rigid Grooved Coupling: 31-1/2-3 Inch(DN40-DN80) 54Size Manifolds, 1-1/4.....................57713AGCP 4-6 Inch(DN100-DN150) 3Size Manifolds, 2 2" ......................57720AGCP FIGURE 5 MODEL RM-1 COMMERCIAL AND RESIDENTIAL RISER MANIFOLDS OPTIONAL PRESSURE RELIEF TRIM INSTALLATION Optional Commercial Manifolds Residential Manifolds Refer to Figure 1 for commercial riser Refer to Figures 2, 3 or 4 for residen- Pressu re manifold features and Figure 5 for pres- tial riser manifold features and Figure sure relief trim components described 5 for pressure relief trim components Relief UM inthis procedure. described in this procedure. Installation Step 1. Remove 1/2 in. pipe plug from Step 1. Remove 1/2 in. pipe plug from manifold tee. Inspect exposed female manifold tee. Inspect exposed female Model RM-1 commercial and resi- tee threads, remove thread sealant tee threads, remove thread sealant dential riser manifold assemblies are remnants or debris as necessary. remnants or debris as necessary. designed to accommodate an optional Step 2. Install Pressure Relief Valve(1) Step 2. Install Pressure Relief Valve(1) pressure relief valve and trim compo- in manifold tee, orienting valve outlet in manifold tee, orienting valve outlet nents(Ref. Figure 5). port perpendicular to and facing away port perpendicular to and facing away Optional pressure relief trim must be from manifold body. from manifold body. installed in accordance with the follow- Step 3. Install 1/2 in. x Close Nipple Step 3. Disconnect drain piping from ing procedures. (2) in pressure relief valve outlet port. threaded outlet of manifold drain valve Notes: Step 4. Disconnect drain piping from as applicable and install 1 in. x Close grooved outlet of manifold TD-1 test Nipple(5) in valve outlet. For assembly in Riser Manifolds and drain valve as applicable and install Step 4. Install Figure 815 Reducing installed and s service, verify the fire Figure 323 Grooved Reducing Tee (4) Tee(4)onto 1 inch x close nipple,align- protection system is de-pressurized on valve outlet by securing with Fig- ing tee branch outlet parallel with pres- and drained. Close the system supply ure 577 Grooved Coupling (5), align- sure relief valve outlet port. Reconnect control valve, set commercial manifold ing tee threaded branch outlet parallel drain piping to Figure 815 tee drain out- test and drain valve DRAIN or open with pressure relief valve outlet port. let as necessary. residential drain valvee to relieve resid- Reconnect drain piping to Figure 323 ual pressure and drain system. Make Step 5. Install 1/2 in. x Close Nipples certain that drainage water will not tee drain outlet as necessary. (2) in pressure relief valve outlet port cause any damage or injury. Note: Refer to Technical Data Sheet and in Figure 815 reducing tee branch Refer to Care and Maintenance section G901 for Figure 577 Grooved Coupling outlet. for other requirements when closing a installation and assembly instructions. Step 6. Install Flexible Hose (3) by fire protection system control valve and Step 5. Install Flexible Hose (3) by threading female ends onto 1/2 in. x placing system in service. threading female ends onto 1/2 in. x close nipples installed on relief valve Apply thread sealant or TEFLON tape close nipple installed on relief valve outlet port and Figure 815 reducing tee on all threaded connections, with the outlet port and onto Figure 323 reduc- branch outlet. exception of internally sealed flexible ing tee branch outlet. Note:Assure Flexible Hose is not sus- hose connections. Note:Assure Flexible Hose is not sus- ceptible to being caught or snagged by ceptible to being caught or snagged by other moving equipment. other moving equipment. TFP963 Page 6 of 8 SWITCH TERMINAL CONNECTIONS UNINSULATED CLAMPING SEVERED LOOPED SECTION CAUTION: PLATE STRIPPED SINGLE An uninsulated section of a TERMINAL ENDS CONDUCTOR single conductor is not \ SEPARATE permitted to be looped around CONDUCTORS CLAMPING the terminal and serve as two PLATE \ separate connections.The TERMINAL wire must be severed to serve INCOMING \ as two separate connections, thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. OUTGOING IMPROPER CONNECTION METHOD PROPER CONNECTION METHOD WIRE NUT LOCAL WIRE NUT FIRE PANEL OR AUDIBLE/VISUAL ADDRESSABLE NEUTRAL ANNUNCIATOR MODULE WHITE WHITE BLACK w� 1 J c�m BLACK D O (LINE/HOT) o w U J z O Z) m Q Z O92QQ O 00 00 CONTACT RATINGS: 00 Two sets of SPDT(Form C) rv� 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min.at 24VDC N NC C M O NC ----------- ® ® ® ® ® NOTE: When connecting to a UL Listed control panel, use panel resistor rating for circuit supervision NOTE: For supervised circuits,see"Switch Terminal Connections"above.The Waterflow Alarm Switch has two switches,one can be used to operate a central station,proprietary or remote signaling unit,while the other contact is used to operate a local audible or visual annunciator. FIGURE 6 MODEL RM-1 COMMERCIAL AND RESIDENTIAL RISER MANIFOLD WIRING GUIDANCE TFP963 Page 7 of 8 DRAIN 07 O O O 00 ro, O Oul Oo 00 O AAa L S�i Nly�0 OFF MARKING TEST MARKING DRAIN MARKING ON HANDLE ON HANDLE ON HANDLE POSITIONED POSITIONED POSITIONED O ON DETENT ON DETENT ON DETENT O O O O O O O MOD TEST A D1 O DRAIN VALVE O O O 0 �O O O O- Oo Oo Oo SIGHT FLOW O O O O O O DRAIN SET TEST CONNECTION DRAIN FRONT CONDITION CONDITION CONDITION VIEW FIGURE 7 MODEL RM-1 COMMERCIAL RISER MANIFOLD TD-1 TEST AND DRAIN VALVE OPERATION Care and tion to the standards of any authority of the NFPA,and any impairment must having jurisdiction.Contact the install- be immediately corrected: Maintenance ing contractor or product manufacturer Alarm/Flow Test Procedure with any questions. Step 1.Place the Model TD-1 Test and TYCO Riser Manifolds RM-1 must be It is recommended that automatic Drain Valve in the TEST position (Ref. serviced and maintained in accordance sprinkler systems be inspected,tested, Figure 7). On residential assemblies with this section. and maintained by a qualified Inspec- without a test orifice,temporarily install Before closing a fire protection system tion Service in accordance with local a test orifice in the drain outlet and fully control valve for inspection or main- requirements and/or national codes. open the Drain Valve. Make certain tenance work on the fire protection Note: No attempt is to be made to that drainage water will not cause any system that it controls, permission to repair any Riser Manifold component damage or injury. shut down the effected fire protection in the field. Only the pressure gauge, Step 2.Verify operation of associated system must first be obtained from waterflow alarm switch, or relief valve alarms. the proper authorities and all person- can be replaced. If any other problems Step 3. Verify that the residual (i.e., nel who may be affected by this action are encountered the entire riser mani- flowing)pressure indicated by the pres- sure gauge is no less that originally After placing a fire protection system The alarm/flow test procedure will recorded for the system when it was in service, notify the proper authorities result in operation of the associated first installed. and advise those responsible for moni- alarms. Consequently, notification Step 4. Close the Drain Valve on the toring proprietary and/or central station must be given to the owner and the fire Residential models and the Test and alarms. department, central station, or other Drain valve on commercial models. The owner is responsible for the signal station to which the alarms are inspection,testing,and maintenance of connected, and notification must be Step 5. Verify that the static (i.e., not their fire protection system and devices given to the building occupants. flowing)pressure indicated by the pres- in compliance with this document, as The following inspection procedure sure gauge is no less that originally well as with the applicable standards must be performed as indicated, in recorded for the system when it was of the NATIONAL FIRE PROTECTION addition to any specific requirements first installed. ASSOCIATION(e.g., NFPA 25), in addi- TFP963 Page 8of8 Limited Orderin Optional 175 psi Pressure Relief Kit Specify: Pressure Relief Kit, Model Warranty Procedure cial ResidentalaManifold,(specify Commer- cial or Residential application),(specify For warranty terms and conditions,visit Contact your local distributor for avail- size range), P/N(specify): www.tyco-fire.com. ability. When placing an order, indi- Commercial cate the full product name, including 1-1/2 in.—3 in.(DN40—DN80) 40721 description and part number(P/N). 4in.—6 in.(DN100—DN150) 40731 Residential Riser Manifolds 1 in.-2 in.(DN25—DN50) ..............40711 Specify:Size(specify)Connection Type Replacement Parts (specify inlet x outlet)Model RM-1 Riser Specify: Model RM-1 Riser Manifold Manifold, P/N (specify): (specify part description), P/N (specify Commercial from Figures 1, 2, 3,4 or 5) 1-1/2 in.(DN40)MT x FT ..............40551 2 in.(DN50)G x G ...................40601 2-1/2 in.(DN65)G x G ................40611 3 in.(DN80)G x G ...................40621 4 in.(DN100)G x G ..................40651 6 in.(DN150)G x G...................40661 Residential 1 in.(DN25)FT x FT..................40671 1-1/2 in.(DN40)MT x FT ..............40571 2 in.(DN50)G x G ...................40591 1400 Pennbrook Parkway,Lansdale,PA 19446 Telephone+1-215-362-0700 m 2018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson 1 nson ORO NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls TEFLON Is a registered trademark of DuPont SYSTEM SENSOR° P2RHK-120 Outdoor . •: 120V Selectable ` Output Horn/Strobe The SpectrAlertO Advance selectable-output outdoor 120V horn/strobe is rich with features guaranteed to cut installation times and maximize profits. SPECT rt A Q V A IV C E Features The SpectrAlert Advance series of notification appliances • Plug-in design s designed to simplify installations,with features such as plug in designs, instant feedback messages to ensure correct installation of • Field selectable candela settings: 135, 150, 177, 185 individual devices,and field-selectable candela settings. • Tamper resistant construction • Outdoor products rated from—40°F to 151°F When installing the P2RHK-120,first attach the 120V mounting plate to the outdoor back box provided with each unit. • Regulated 120VAC • Rotary switch for horn tone and three volume selections Next,connect the notification appliance circuit wiring to the SEMS • Outdoor products listed to UL 1638(strobe)and UL 464(horn) terminals on the mounting plate. outdoor requirements Finally,attach the horn/strobe to the mounting plate by inserting the • Outdoor products rainproof per UL 50(NEMA 3R) product's tabs in the mounting plate's grooves.The device will rotate • Weatherproof back box included into position, locking the product's pins into the mounting plate's • Single screw attachment terminals.The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. • Horn/strobe, 120VAC adapter mounting plate,and weatherproof back box included The SpectrAlert Advance series outdoor notification appliances • Listed for ceiling or wall mounting are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Agency Listings SIGNALING UL MEA xO 7300-1653:187(outdoor strobes) 7125-i653:188(horn/strobes LISTED approved S4011 MEA452-05-E S5512 S3593 SpectrAlert Advance Specifications Architect/Engineer Specifications The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horn/strobe shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Physical/Electrical Specifications Operating Temperature —40°F to 151 of(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 120VAC Operating Voltage Range 96—132VAC Input terminal wire gauge 12 to 18 AWG Dimensions 5.71 x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Candela Derating For K series products used at low temperatures,listed candela ratings must be reduced in accordance with this table. StrobeOutput Listed Candela Candela rating at—40°F 135 135 150 150 177 177 185 185 P2RHK-120 Dimensions P2RHK-120 Mounting �4.7" 2.5" 120V MOUNTING PLATE MP120K O 2 0o 0 5.6" � 5.7" a 0 o O 0 � m � m m � o Wall-mount horn/strobes 5.1"� Wall weatherproof back box SpectrAlert Advance Ordering Information Model Description -.A P2RHK-120" 2-wire Horn/Strobe,High cd,Red,Outdoor, 120VAC Notes: `Includes P2RHK 2-wire horn/strobe,MP120K 120VAC adapter mounting plate,and weatherproof back box. "High cd,"refers to strobes that include 135,150,177,and 185 candela settings. All outdoor units ending in"K"include a weatherproof back box. systemsensocco SYSTEM ©to change without notice.Vis System Sensor. 1\ ``, 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change m AN! SEAM4OJ7 Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of this data sheet. AVDS01700•03/12 February 26, 2014 Sprinkler 106a C QUICK RESPONSE NIKJNG* DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Quick Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry HSW Sprinklers are available in various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indi- cated in the Approval Charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) _ NOTE: When installed in some corrosive environments, the Polyester finish may change color.This natural discoloration over time is not in itself an indi- cation of corrosion and should not be treated as such.All sprinklers installed For Light Hazard Occupancies Only in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. 2. LISTINGS AND APPROVALS O cULus Listed: Category VNIV c °S FM Approved: Classes 2013 and 2015 FM NYC Approved: MEA 89-92-E, Volume 15 Refer to Approval Chart 1 and Design Criteria on page 106c for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 106d for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1993. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested pneumatically to 100 psi (6.89 bar) Thread size: 1" NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric')for all listed and approved lengths. Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65 °F (-55 °C) Material Standards: Viking Technical Data may be found on Frame Casting: Brass UNS-C84400 The Viking Corporation's Web site at Deflector: Phosphor Bronze UNS-051000 http://www.vikinggroupinc.com. Bulb: Glass, nominal 3 mm diameter The Web site may include a more recent Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with edition of this Technical Data Page. PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C31400 or UNS-C31600 Pip Cap Adapter: Brass UNS-C36000 Orifice: Copper UNS-C22000 or UNS-C11000 Tube: ERW Hydraulic Steel Tube Support(Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Order QR Dry HSW Sprinklers by first adding the appropriate suffix for the sprinkler finish,the appropriate suffix for the temperature rating, and then the suffix for the length("A'dimension)to sprinkler base part number.Order in a specific length noted as the"A"dimension.The "A"dimension is the distance from the face of the fitting (tee)to the desired finished surface of the wall in which it is to be installed. These sprinklers are listed and approved in lengths from 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm)for the adjustable standard style, 3"to 47"(76.2 mm to 1,194 mm)for the plain barrel style,and 3-1/4"to 47-1/2"(82.5 mm to 1,207 mm)for the adjustable recessed style. Form No. F_031993 Replaces page 106a-h, July 17, 2013. (Removed Seal Part Number) Sprinkler 106b February 26, 2014 C QUICK RESPONSE N I KJ NG4 DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Lengths exceeding the standard lengths are available,with no approvals,on a"made-to-order"basis: Recessed Dry HSW up to 65- 1/2" (1,664 mm).Adjustable Standard Dry HSW up to 63-1/2" (1,613 mm). Plain Barrel Dry HSW up to 65"(1,651 ni Contact the manufacturer for more information. Finish Suffix: Brass =A, Chrome = F, White Polyester= M-/W, and ENT=JN Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G Escutcheon Suffix=Y for the adj. recessed sprinkler with the Model G-1 Escutcheon (no suffix needed for the Model E-1 Escutcheon). For example, sprinkler VK182 with 1" NPT Threads, a Chrome finish, a 155 °F (68 °C) temperature rating, the Model G-1 Escutcheon, and "A" length of 10" = Part No. 08386UFBY10. NOTE: Sprinkler is turned sideways Available Finishes And Temperature Ratings: Refer to Table 1. or clarity (Refer to Figures 2-7 Accessories: (Also refer to the"Sprinkler Accessories"section.) for correct deflector orientation) Sprinkler Wrenches: Protective A. Standard Wrench: Part No. 07297W/B (available since 1991) Sprinkler B. Wrench for recessed sprinklers: Part No. 07565W/B" (available since 1991) Shield "A'/2"ratchet is required (not available from Viking). Dry Sprinkler Protective Cover: Part No. 15610 Replacement Escutcheons: A.Adjustable Standard Dry Escutcheon: Base Part No. 08086F B. Model E-1 Recessed Dry Escutcheon Cup: Base Part No. 05459A 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Wrench 5. OPERATION Flat During fire conditions, the heat-sensitive liquid in the glass bulb expands, - causing the glass to shatter, releasing the internal parts to open the water- way. Water flowing through the sprinkler orifice strikes the sprinkler deflector, vIKIN� °z9 O forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Figure 1: Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. Standard Sprinkler Wrench 07297W/B 7. AVAILABILITY The Viking Quick Response Dry Horizontal Sidewall Sprinkler is available through a network of domestic and international distribu- tors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' CeilingTemperature2 Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 OF (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F 93 °C 150 °F 65 °C Green High 286 °F 141 °C 225 °F 107 °C Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion-Resistant Coating3,4: White Polyester and ENT in all temperature ratings Footnotes 'The sprinkler temperature rating is stamped on the deflector. 2 Based on 13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indi- cated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Note: These coatings are NOT corrosion proof. Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environment.Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. "When installed in some corrosive environments,the Polyester finish may change color.This natural discoloration overtime is not in itself an indication of corrosion and should not be treated as such.All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. February 26, 2014 Sprinkler 106c lR QUICK RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com +xNote: A 1/2' ratchet is required. Sprinkler Wrench Part (Not available from Viking) No. 07565W/D" for installing recessed - dry sprinklers. -- r.___________- I 1 ( --___________ I I I lj { -r tz Step 1: Carefully slide the Step 2 Press the wrench on wrench sideways around the the sprinkler wrench flats and deflector and protective turn slightly to ensure engage- shield as shown, ment with the wrench flats, Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Horizontal Sidewall Sprinklers For 'A' Dimension 1, Determine the distance from the face of Deflector at NOTE the tee to the finished face of the wall. Minimum Distance To locate the deflector 2. Round to the nearest 1/2' (12.7 mm) between Finished Ceiling From wall at the minimum distance 1-1/2' (38.1 mm) and 45-1/2' (1,156 mm), from the wall, with no adjustment available, NOTE: The deflector will extend approximately _ Finished Wall order the standard dry 4-1/8' (104.8 mm) from the wall with 2' +/- 4' (102 mm) Minimum horizontal sidewall sprink- 1' (25,4 mm) horizontal adjustment available. 6' (152 mm) Maximumw ter 1' (25,4 mm) shorter A 3-1/6' than the 'A' Dimension. (79.4 mm) --- Deflector at NOTE: 3-1/16' - Maximum Distance To locate the deflector (77.8 mm) From wall at the maximum distance from the wall, with no adjustment available, order the standard dry (15.9 mm)J -- horizontal sidewall sprink- Minimum wall o enin ter 1' (25.4 mm) longer P g I 5-1/e' than the 'A' Dimension. diameter) 1-3/4' (44,5 mm). Sleeve diameter: (130.2 mm) Maximum wall opening 1-1/2' (381 mm), dlameterl 2-1/4' (57 mm). 13/16' Sleeve finish matches x May be allowed up to 18' (457 mm) for certain (20.6 mm) finish of escutcheon. FM installations. Refer to the appropriate installation standards, including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. Figure 3: Adjustable Standard Dry Horizontal Sidewall Sprinkler Slot Deflector P Slot Push and Rotate ElSleeve P�-4— STEP 11 Align the slot in STEP 21 Push the rounded STEP 31 Pull the escutcheon STEP 41 Push and rotate STEP 51 To minimize the escutcheon with the end of the slot against the away from the near edge the escutcheon onto the visibility of the slot horizontal surface of near edge of the deflector. of the deflector. Move the sleeve. in the escutcheon, the deflector as shown, Push the far side of the near side of the escut- position the slot escutcheon past the deftec- cheon over the deflector, at the top of the tor, toward the sleeve. sprinkler sleeve. Figure 4: Adjustable Standard Escutcheon Installation Sprinkler 106d February 26, 2014 C QUICK RESPONSE N I KJ NG4 DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 1 (UL) Temperature KEY Quick Response Dry Horizontal Sidewall Sprinklers ��Finish For Light Hazard Occupancies Only A1XF Escutcheon(if applicable) Maximum 175 PSI (12 bar)WWP Sprinkler Base Thread Size Nominal Order Length Listings and Approvals' Part No.' SIN Style K-Factor2 Increment (Refer also to Design Criteria on page 106e.) NPT BSP U.S. metric' Inches mm cULuss NYC6 VdS LPCB C E 0 08384U Adjustable 1" -- 5.6 80.6 1/2" 12.7 A1,A5 Al -- -- -- 16458U VK178 Standard -- 25 mm -- 80.6 1/2" 12.7 A1,A5 08386U VK182 Adjustable 1" -- 5.6 80.6 1/4" 6.35 B2, B6 B2 -- -- -- 16454U Recessed -- 25 mm 80.6 1/4" 6.35 B2, B6 - -- -- -- 08388U 5.6 80.6 1/2" 12.7 A3 A4 -- -- 16456U VK174 Plain Barrel 25 mm - 80.6 1 1/2" 1 12.7 1 A3 Approved Finishes and "A" Dimensions 1* - Chrome, or White Polyester' sprinkler with a Chrome, Brass, or White Polyester Sleeve and Escutcheon with"A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) Approved Temperature Ratings 2* - Chrome, or White Polyester' with "A" dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 A- 155 °F (68 °C), 175 °F (79°C), 200 °F mm) (93 °C), and 286°F(141 °C) 3-Chrome, Brass,White Polyester',or ENT'with"A"dimensions 3"to 47"(76.2 mm to 1,194 mm) B - 155 °F (68 °C), 175 °F (79 °C), and 4-Chrome or Brass with"A"dimensions 3"to 47" (76.2 mm to 1,194 mm) 200 °F (93 °C) 5- ENT'sprinkler with an ENT'Sleeve and Escutcheon with"A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) 6- ENT'with "A" dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) `Brass Finish is listed and approved but not standard offering,lead times of 6-8 weeks required. (Matching Brass escutcheons are not available.) Footnotes ' Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). 3 Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. °This chart shows the listings and approvals available at the time of printing.Other approvals may be in process.Check with the manufacturer for any additional approvals. 5 Listed by Underwriter's Laboratories for use in the U.S.and Canada for Light Hazard occupancies only. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E,Vol. 15. 'cULus Listed as corrosion resistant. DESIGN CRITERIA- UL (Also refer to Approval Chart 1 above.) NOTE:When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees.When selecting other CPVC fittings, contact Viking Technical Services. CULus Listing Reguirements: Quick Response Dry Horizontal Sidewall Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edi- tion of NFPA 13 for standard spray sprinklers. • Limited to Light Hazard occupancies only. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. • Minimum spacing allowed is 6 ft. (1.8 m). • Deflector must be positioned between 4" and 6" (102 mm and 152 mm) below the ceiling. Keep the top of the deflector oriented parallel with the ceiling. • Locate no less than 4"(102 mm)from end walls. • Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers.The distance shall be measured perpendicular to the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page DRY1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB,APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards,whenever applicable. February 26, 2014 Sprinkler 106e R QUICK RESPONSE NIKJNG* DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) Temperature KEY Quick Response Dry Horizontal Sidewall Sprinklers �Finish AL For Light Hazard Occupancies Only A1XF Escutcheon(if applicable) dL Maximum 175 PSI (12 bar)WWP Sprinkler Base SIN Style Thread Size Nominal K-Factorz Order Length Increment FM Approvals° Part No. NPT BSP U.S. metric' Inches mm (Refer also to Design Criteria below.) 08384U 1" -- 5.6 80.6 1/2" 12.7 Al VK178 Adjustable Standard 16458U -- 25 mm -- 80.6 1/2" 12.7 Al 08386U 1" -- 5.6 80.6 1/4" 6.35 B2 VK182 Adjustable Recessed 16454U - 25 mm -- 80.6 1/4" 6.35 B2 08388U ill -- 5.6 80.6 1/2" 12.7 A3 VK174 Plain Barrel 16456U - 25 mm -- 80.6 1/2" 12.7 A3 Approved Finishes and "A" Dimensions 1'- Bright Brass,Chrome,White Polyester,or ENT'with "A" dimensions 1-1/2"to 45-1/2" (38.1 Approved Temperature Ratings mm to 1,156 mm)2*- Bright Brass,Chrome,White Polyester,or ENT5 with "A" dimensions 3-1/4"to 47-1/2" (82.5 A- 155 °F(68 °C), 175 °F(79°C), 200 °F(93 °C), and mm to 1,207 mm) 2 °F(141 °C) 3 - Brass, Bright Brass, Chrome,White Polyester,or ENT'"A"dimensions 3"to 47"(76.2 mm to B- 155°F(68°C), 175°F(79°C),and 200°F(93°C) 1,194 mm) *Brass Finish is listed and approved but not standard offering,lead times of 6-8 weeks required. (Matching Brass escutcheons are not available.) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). 3 Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 4 This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. ' FM approved as corrosion resistant. DESIGN CRITERIA- FM (Also refer to Approval Chart 2 above.) NOTE:When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees.When selecting other CPVC fittings, contact Viking Technical Services. FM Approval Reauirements: The Dry HSW Sprinklers in the Approval Chart above are FM Approved as quick response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets(including 2-0)and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to:minimum water supply requirements,hydraulic design,ceiling slope and obstructions,minimum and maximum allowable spacing,and deflec- tor distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT.Always refer to Bulletin Form No. F_091699-Care and Handling of Sprinklers.Also refer to page DRY1-3 for general care, installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data,the appropriate standards of NFPA, FM Global, LPCB,APSAD,VdS or other simi- lar organizations, and also with the provisions of governmental codes, ordinances,and standards,whenever applicable. Sprinkler 106f February 26, 2014 PV C QUICK RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com For "A' Dimension: 1. Determine the distance from the face of the tee to the face of the finished wall, 2, Round to the nearest 1/4' (6,35 mm) between 3-1/4' (83 mm) and 47-1/2' (1,207 mm). Ceiling NOTE: The sprinkler will be recessed approximately Wall 5/16' (7.9 mm) with 5/8' 06 mm) horizontal adjustment available 4' (102 mm) Minimum 6" (152 mm) Maximum)( A 5/8' (16 mm) 3-1/16' _rd (77,8 mm) Minimum wall opening: 2-1/8' (54 mm) diameter. Maximum wall opening: 2-1/2' (63.5 mm) diameter. Available Adjustment 1-23/32' (43.7 mm) Minimum May be allowed up to 13' (457 mm) for certain 2-11/32' (59,5 mm) Maximum FM installations. Refer to the appropriate Installation standards, including NPPA 13 and/or PM Loss 5/16" (7,9 mm) Outward Adjustment Prevention Data Sheet 2-0 5/16' (7 9 mm) Inward Adjustment Figure 5: Adjustable Recessed Dry Horizontal Sidewall Sprinkler with the Model E-1 Escutcheon Side outlet of Tee turned to req'd angle for For 'A' Dimension: slope of ceiling I 1, Measure B Dimension from centerline of the face of the tee to the horizontal centerline of the wall opening. Adjustable Adapter 2. Measure C Dimension from the centerline of Ring the Face of the tee to the finished wall q 3. Calculate 'A' Dimension using: A = B2+ C 2 NOTE, A Dimension will provide approximately 1/4' of adjustment In either direction. Depth,, 1-1/16' (27 1/8' (3.2 mm) z. Adjustable Ceiling Outer Cup �Deflector distance 4-6' (102 to 152 mm) 2-5/8' 4' below the ceiling K (66 mm) (102 mm) Minimum wall opening: When measuring for 2-5/8' (66 mm) diameter. the 'A' Dimension, JI— Maximum wall opening: the exact deflector 3-3/4' (95 mm) diameter, :"_�Wall distance below the z ceiling must be known, C )K May be allowed up to 18' (457 mm) 1-1/16' for certain FM installations. Refer to (27 mm) the appropriate installation standards, Including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. Figure 6: Adjustable Recessed Dry Horizontal Sidewall Sprinkler with the Model G-1 Escutcheon February 26, 2014 Sprinkler 106g R QUICK RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS -NIKJW*i The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com For "A" Dimension 1, Determine the distance from the face of the tee to the base of the sprinkler. Ceiling 2 Round to next highest 1/2' (12.7 mm) increment, between 3" (76.2 mm) and ��Wall 47' (1,194 mm). 4" (102 mm) Minimum 6" (152 mm) Maximumx q 2-3/16' (51 mm)� (16 mm) Outside diameter; 1-5/16"J (33A mm), (Same as 1" Do not exceed 6" (152 mm), (25 mm) Schedule 40 pipe Do not recess wrench boss, May be allowed up to 10' (457 mm) for certain FM installations, Refer to the appropriate installation standards, including NPPA 13 and/or PM Loss Prevention Data Sheet 2-0. Figure 7: Quick Response Plain Barrel Dry Horizontal Sidewall Sprinkler Top View- Dry HSW Sprinkler Side View- Sprinkler Cover 15610 NOTE: Shown with an Adjustable Standard Dry HSW Sprinkler. The protective cover may also be used with the Adjustable Recessed Press the cover together or Plain Barrel style Dry HSW Sprinkler. until it snaps closed. T-R After the sprinkler is installed, f carefully place the cover over the dry sprinkler as shown. NOTE: Remove the sprinkler clip and cover before placing the system in service! Figure 8: Dry Horizontal Sidewall Sprinkler Cover Part Number 15610 (shown with an Adjustable Standard Dry HSW Sprinkler) (Optional for temporary use with Viking Dry HSW Sprinklers until finish work is completed around the sprinkler.) Sprinkler 106h February 26, 2014 C QUICK RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 5-1/8' (130.2 mm) Seal the clearance space around the sprinkler barrel to avoid ii ii ii Maximum leakage of air into the protected area and consequent formation of condensate around the sprinkler frame, which could Inhibit TDeflector operation or cause premature operation. Refer to Figure 10. If humidity and temperature 01 !! NOTES To locate the differential causes condensation II III _ ______ atI deflector at the on the exposed dry sprinkler IIIIIIII =____________ Maximum Dlstancemaximum distance from ______ From Wallbarrel, consider wrapping the the wall, with no exposed barrel with insulation, IIIII 13/16" adjustment available, foam insulating tape, or equivalent. IIIIIIII (206 mm) g order the standard IIIIIIII 4' (102 mm) Minimum dry horizontal 1' de- Install the 1" NPT threaded I I I wall sprinkler 1" end of the dry sidewall sprink- 6' (152 mm) Maximums Longer than the 'A' ler into the 1" NPT outlet of Sleeve finish dimension. a malleable iron tee fitting per j;;j;;j; matches ANSI B 16.3 (Class 150) or cast escutcheon iron threaded tee fitting per 3-1/16° Up to 2' (50.8 mm) ANSI 16.4 (Class 125) only, adjustment is available. (77.8 mm) - 5/8- Minimum wall openingi ii ii (15.9 mm) 3-1/8' diameter 1-3/4' (44.5 mm) " " i n (79.4 mm) Maximum wall opening (Exposed ii ii " " " Minimum diameter 2-1/4' (57 mm). Barrel) 1-1/2' NOTE• To locate the (38.1 mm) ii ii ii deflector at the diameter _ minimum distance from Ambient XP sed BarretOuter the wall, with no Temperature Ambient Temperature Surface adjustment available, of Protected 40°F/4°C 50°F/10°C 60°F/l6°C of the Wall order the standard Area)KX at the Exposed Minimum Barrel dry horizontal side- Discharge End Lengthrrr Face of the ii ii ii wall sprinkler 1" of the Sprinkle Tee to the Outer Deflector at shorter than the Surface of the Wall Minimum Distance 'A' dimension. In.(mm) In.(mm) In.(mm) From Wall 40°F WC) 0 0 0 30'F (-1°C) 0 0 0 May be allowed up to 18' (457 mm) for certain FM 20°F (-7°C) 4 (100) 0 0 installations. Refer to the appropriate installation standards, 10°F (-12°C) 8 (203) 1 (25.4) 0 including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. 0°F (-18°C) 12 (305) 3 (76) 0 xxThe protected area refers to the area below the ceiling, -10°F (-23°C)14 (356) 4 (102) 1 (25.4) The ambient temperature is the temperature at the discharge end of the sprinkler. -20°F (-29°C)14 (356) 6 (152) 3 (76) For protected area temperatures that occur between the -30°F (-34°C)16 (406)8 (203 4 (102) values listed, use the next cooler temperature. -40°F (-40°C)18 (457)8 (203)4 (102) The minimum required barrel length is not the same as the "A' dimension -50°F (-46°C)20 (508)So (254 6 (152) Refer to Figures 3, 5, and 7 for the "A" dimension, -60-F (-51°C)20 (508)10 (254 6 (152) Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Figure 9: Dry Horizontal Sidwall Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry HSW Sprinkler is Shown) Seal Seal (or equivalent method) Clearance Opening Insulated Insulated Wall Wall Dry Sprinkler Seal on the Exterior of the Wall Dry Sprinkler Seal Within the Wall Figure 10: Dry Sprinkler Seal(Adjustable Standard Dry HSW Sprinkler is Shown) Form No. F_031993 Replaces page 106a-h, July 17, 2013. (Removed Seal Part Number) Page 1 of 5 ® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. 1. DESCRIPTION Viking Freedom") Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive,glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired.The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to Y2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. I 2. LISTINGS AND APPROVALS c @L us UL Listed (C-UL-US-EU): Category VKKW eu Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass-bulb fluid temperature rated to-65 °F (-55 °C) *Metric K-factor measurement shown is in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom° Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A and ENT= JN Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C)temperature rating = Part No. 20759AE. Cover Plate Assembly: Base Part No. 13504 (2-3/4"diameter), Base Part No. 13642 (3-5/16"diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Form No. F_012116 16.06.27 Rev 16.1 (New product, new page) Page 2 of 5 ® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix:Polished Chrome=F, Brushed Chrome=F-/B, Bright Brass=B,Antique Brass=B-/A, Brushed Brass=B-/B, Brushed Copper= E-/B, Painted White = M-/W, Painted Ivory= MA, Painted Black = M-/B Temperature Suffix: 135°F/57°C=A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories"section of the Viking data book.) Sprinkler Wrenches": A. Heavy Duty Part No. 14047W/B** (available since 2006), or B. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a''/i'ratchet(not available from Viking).***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature,the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. . Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres- sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Sprinkler Maximum Temperature Rating Cover Large Square Nominal Ambient of the Cover Plate Cover Plate Cover Plate Temperature Temperature Ceiling Assembly Base Part Base Part Base Part Bulb Color Classification Rating' Temperature (Required)' Number° Number° Number4 Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C) 13504 13642 15394 Red Intermediate 175 °F (79 °C) 150 °F (65 °C) 135 °F (57 °C) 1 13504 1 13642 1 15394 1 Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) 135 °F (57 °C) 13504 13642 15394 Green Sprinkler Finishes: Brass and ENT Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass,Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings5: ENT Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13, NFPA 13R,and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location,and other requirements of the Authority Having Jurisdiction.Refer to specific installation standards. s Maximum ambient temperature for cover assembly is 100°F(38°C). 4 Part number shown is the base part number.For complete part number,refer to current Viking price list schedule. 5 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environment.For automatic sprinklers,the ENT coating is applied to all exposed exterior surfaces,including the waterway.For ENT coated sprinklers,the Belleville spring is exposed. Form No. F_012116 16.06.27 Rev 16.1 Page 3 of 5 ® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Approval Chart Viking VK494, 4.9 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13,refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base SIN NPT Thread Size Nominal K-Factor Maximum Water Wor- Part Number' Inches mm U.S. metric 2 king Pressure 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) Max. Coverage Flow Pressure Listings and Minimum Area 6 GPM PSI (bar) Deflector to Installation Approvals3,s Spacing(LPM) Ceiling Type Ft. Ft.X Ft. 155°F(68°C),175°F(79°C),200°F(93°C) 4 c us (m) (m X m) Temperature Rated Sprinklers EO 12 X 12 13 7.0 (3.7 X 3.7) (49.2) (0.48) 14 X 14 13 7.0 (4.3 X 4.3) (49.2) (0.48) Concealed with 16 X 16 13 7.0 Cover Plate See Footnotes T10,&11 8 (4.9 X 4.9) (49.2) (0.48) Refer to Figure 2 Assembly. (2.4) 18 X 18 17 12.0 See Footnote 9. (5.5 X 5.5) (64.4) (0.83) 20 X 20 20 16.7 (6.1 X 6.1) (75.7) (1.15) Footnotes Part number shown is the base part number. For complete part number,refer to current Viking price schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa,divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. °Listed by Underwriter's Laboratories,Inc.for use in the U.S.,Canada,and European Union. e Meets New York City requirements,effective July 1,2008. 6 For areas of coverage smaller than shown,use the"Flow"and"Pressure"for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum"Flow"and"Pressure'used. Cover Temperature Rating is 135°F(57°C). Cover Part No. 135041,13642'(large diameter),or 15394'(square cover plate). e Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 0 Accepted Cover Plate Finishes are:Polished Chrome,Brushed Chrome,Bright Brass,Antique Brass,Brushed Brass,Brushed Copper,Painted White,Painted Ivory,or Painted Black 9. "C-UL-US-EU Listed as corrosion resistant-Electroless Nickel PTFE(ENT) Form No. F_012116 16.06.27 Rev 16.1 Page 4 of 5 ® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listina Reauirements(C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R,apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13:The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers.The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq.ft.over the"design area"in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT.Always refer to Bulletin Form No. F 080415- Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data,the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly 2-1/4" (57 mm) • Protective cap removed • Use wrench 14047W/B** diameter opening required in the ceiling. Sprinkler Wrench Part No. 14047W/B** Step 1: Step 2: 1 1 Carefully slide the Carefully press the wrench upward and wrench sideways around turn slightly to ensure engagement with the deflector and pins the sprinkler wrench flats. Sprinkler a wrench flat NEVER install the sprinkler by applying the installation Sprinkler wrench across the frame arms. DO NOT overtighten. frame arms Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**.A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Figure 1: Sprinkler Installation and Proper Wrench Usage ink A 1/2"ratchet is required(Not available from Viking) Form No. F_012116 16.06.27 Rev 16.1 Page 5 of 5 ® FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. 1/2" (15 mm) NPT 2-9/16" (65 mm) Maximum 2-1/16" (52 mm) Minimum E 00E '74 N LO a 2-3/4" (70 mm) or NOTE: Upon sprinkler activation, the deflector descends 3-5/16" (84 mm) to approximately 13116"(21 mm)below the sprinkler body. Figure 2: Sprinkler Dimensions and Cover Installation QQ�\�--p C US 7-0 a �2 O O VIKING" All custom color painted cover plates will have an identifying label affixed to the inside of the cover that go BPI indicates the custom color and will have a representative 3-5/16" (84 mm) sample(a paint dot)of the paint on the label. Figure 3: Identification of Custom Paint for Concealed Covers Figure 4: Square Cover Assembly 15394 Form No. F_012116 16.06.27 Rev 16.1 (New product, new page) oc �W W� SEE CIVIL DWG FOR UG SUPPLY 3 zK NB-1 Heodset Mounting Bracket - and No Block Hanger 3 Offset Hanger /¢ .w. o 1 o Composite Wood Joist\ 1'I]HI' 1' 's lal t'/' 1 j' 1' Headset T 8-2'/ • 8-5 m 5-3 4-6 B-2V 6-3'/z e r lax Gyp.Board Ceiling 0e 3-/¢ 6-0 8-0 48,= _,,,_ - CPVC HANGER DETAIL "A" - S - II "l' I0 8 1 p Dry Sidewall _4 2 0 a - I � \ L Dry Sidewall 11-3Yi =3- \ 1 THIS SYSTEM IS DESIGNED PER SPRINKLER MANUFACTURER'S LISTING. ( - \ NB-2 Headset M—Ung Brockst SEE ATTACHED CUT SHEETS FOR MANUFACTURER'S MIN. REQUIREMENTS. D \ and No Block Hanger A TOTAL OF (4) HEADS OPERATING USING RESIDENTIAL, CONCEALED. G \\ \ 2 INSTALLATION TO CONFORM WITH NFPA #13R & ARLINGTON FIRE DEPT. \ > 3 ALL MATERIAL TO BE NEW, U.L. LISTED, AND PER NFPA #13. -- -m 1/1 4- 1 3 \\\ /// Offset Hanger 4 ALL FITTINGS TO BE CPVC U.N.O. \ / Wood Joist 5 ALL PIPE TO BE CPVC U.N.O. \ / 6 PROTECTION OF HEADS FROM PAINT BY OTHERS. / 7 ALL ELECTRICAL WIRING BY OTHERS. 13RJ I 1' 1' Headset 1 11-31/¢ -11 4-91¢ HYDRAULIC CALCULATIONS ARE BASED ON 16'x16'SPACING e Gyp.Board Ceiling 0 O 90 ELBOW 1, ], r0 SYSTEM 3/2 It 4 9 r G PVC HANGER D ETA L r r B" ryV Check VA.lyr.. 1.5-CENTRAL MODEL 13R RISER MANIFOLD W/: -- - \ (I)DRAIN AND TEST (2)FLOW SWITCH SPARE HEAD CABINET J —(3)PRESSURE GAUGE READS&WRENCH 4 (4)SIGNS ON BODY 3 // \> O a�1a 0 WEATHERPROOF HORN STROBE 1'/r AM ES MODEL 2000B-FP 2.5'Single Outlet FDC PER ARLINGTON FIRE DEPT, 4' DOUBLE CHECK VALVE 12- 3-8/ / � Dry Sidewall I 1• 21/2'x1'/i REDUCER 2 0 Dry Sidewall 1' 6'x2'/i REDUCER ]04 I FINISH FLOOR: 1 1� 6'SUPPLY L _T - 9-2 -0 1' - 1'/ " _ - Riser Detail 1 Test Sprinklers. 0 8-2 8-5 p 5-3 4-6 14-6 L-------J L---------U Ground Floor Plan /8°=r-1, GROUND FLOOD W .........W........N............. E ASMINOTO OENFIFIOATE OF COWETENOT � It FIRE FAOTEOTmm srotwI LEI SYSTEM! It Khosrow(David)Foranenl 1 7325-0195-C Leve13 1 1 Nor-Tech Fire Protection,Inc. I NORTEF 6 E■I 91 n/i sy..ew 1anlrea 1 ............................. WATER FLOW INFORMATION: HANGER LEGEND STANDARD SYMBOLS SPRINKLER HEAD SYMBOLS MK DATE BY REVISIONS - LOCATE BY GRID COORDINATES FIELD INSPECTION BY PHONE CONTRACT WITH PROJECT 31st Avenue Apartments Building C STATIC:90.0 PSI SPRINKLERS SYMB. MODEL ID# THREAD "K" FINISH ESCUTCH. TYPE DEGREE QTY. 1.Arlington Fire Dept. 360403-3600 GR&R Properties RESIDUAL:39.0 PSI VIKING RESIDENTIAL SPRINKLER 0 VK494 20759 BRASS WHITE CONC. 155' 65 2. 16000 Chritensen Road#150 ADDRESS:18321 31 st Ave NE FLOW:2,575 GPM VIKING DRY SIDEWALL QUICK RESPONSE SPRK VK178 08384U 1' 6 CHR. CHR. DSW 155' 4 3, Seattle,WA 98188 CITY Arlington,WA 98223 APPROXIMATE HYDRANT ELEVATION(ft)? 5 4. 805-368-9466 aD TITLE: FIRE SPRINKLER PLAN PRESSURE 7ONE:XXX x FLOW AVAILABLE®20 PSI,—GPM WATER DEPT. ARCHITECT ED� D.F. o..e:9/8/20 CONTRACT p. PITOT READING:? ncDenny rc a re TEST DATE:XXX ADDRESS 3726 Meridian Ave N NORTH a 20030 REO NE;WAS Hill Road 805 s 96020 TEST LOCATION:XXX CITY CITY Seattle,WA 98103 REOMONl WA FAX 121TON 11-7 SHEET N0. 112 WATER DEPARTMENT JURISDICTION:Arington SCALE: TOTAL SPRINKLERS THIS DRAWING 69 PHONE PHONE 206-697-6025 1/4"=1'-0" NOR-TECH FIRE PROTECTION INC. uCENSE No.NOKTEFP051P6 FP-1 of 3 I I e A, -m r 8-24 O 8-5 5-3 4-6 - 8'-0' ° --- - -9-3/ 2 O 1' 1' NB-1 Headset Mounting Bracket 6-0 8-0 and No Block Hanger 4. 1 \ Offset Hanger 1' O p1' 8 Dry Sidewall U Ip_q Composite Wood Joist\ O 0 Dry Sidewall /LH"ecd,,s,,t Board Ceiling P I \ \ \\ I \ \ \ \ i 1yz 4- e 3 \ i -- w \\ CPVC HANGER DETAIL "A" 1 1' 1' 1 11-31/e 1 11 4-91 0 e glz/_` 1 THIS SYSTEM IS DESIGNED PER SPRINKLER MANUFACTURER'S LISTING. NB-2 Headset MoantingBracket SEE ATTACHED CUT SHEETS FOR MANUFACTURER'S MIN. REQUIREMENTS. aad No Block Hanger A TOTAL OF (4) HEADS OPERATING USING RESIDENTIAL, CONCEALED. 2 INSTALLATION TO CONFORM WITH NFPA #13R & ARLINGTON FIRE DEPT. 3 ALL MATERIAL TO BE NEW, U.L. LISTED, AND PER NFPA #13. offset Hanger 4 ALL FITTINGS TO BE CPVC U.N.O. Wood Joist 5 ALL PPE TO BE CPVC U.N.O. 6 PROTECTION OF HEADS FROM PAINT BY OTHERS. > 7 ALL ELECTRICAL WIRING BY OTHERS.4 9' Headset HYDRAULIC CALCULATIONS ARE BASED ON 16'x16'SPACING � ' .1 Gyp.Board Ceiling Dry Sidewall - 2 0 Dry Sidewall 1' _ = 10-4 d1wy/ CPVC HANGER DETAIL 99B" V0. — O Test Spdnklem. e e I' • 1' 1' N 1' 1' 8-2 6-5 Q 1-3 4-6 14-6 Second Floor Plan 0 2ND LOOR II�rR�T•R r.T j OERTIFIOIITE OF OOI�ETEROT Fa FIRE FAOTEOTRIM srRmI LER SYSTEM! 7325.01 (David)sB i 3 nl � 1 7325.0195•C Leva13 � 1 1 Nor-Tech Fire Protection,Inc. I NORTEF 6 EI 91 ne i sy-.ew 1anlrea 1 ............................. WATER FLOW INFORMATION: HANGER LEGEND STANDARD SYMBOLS SPRINKLER HEAD SYMBOLS MK DATE BY REVISIONS - LOCATE BY GRID COORDINATES FIELD INSPECTION BY PHONE CONTRACT WITH PROJECT 31st Avenue Apartments Building C STATIC:90.0 PSI SPRINKLERS SYMB. MODEL ID# THREAD "K" FINISH ESCUTCH. TYPE DEGREE QTY. 1.Arlington Fire Dept. 360403-3600 GR&R Properties RESIDUAL:39.0 PSI VIKING RESIDENTIAL SPRINKLER 0 VK494 20759 'Y 49 BRASS WHITE GONG. 155 64 2. 16000 Chritensen Road#150 ADDRESS:18321 31 st Ave NE FLOW:2,575 GPM VIKING DRY SIDEWALL QUICK RESPONSE SPRK VK178 08384U 1' 56 CHR. CHR. DEW 155' 4 3. Seattle,WA 98188 CITY Arlington,WA 98223 APPROXIMATE HYDRANT ELEVATION(ft)? 4. 805-368-9466 aD TITLE: FIRE SPRINKLER PLAN PRESSURE ZONE:XXX x FLOW AVAILABLE 0 20 PSI,—GPM WATER DEPT. ARCHITECT ED D.F. acre:9/8/20 coNTRACT A. PITOT READING:? nc enny rc i e re TEST DATE:XXX ADDRESS 3726 Meridian Ave N NORTH a 20030 NE Novelty Hill Road-Box B 96020 TEST LOCATION:XXX CITY CITY Seattle,WA 98103 REDMOND,IHINGTON 98053 SHEET NO. 425-898-1112 WATER DEPARTMENT JURISDICTION:Arlington SCALE: TOTAL SPRINKLERS THIS DRAWING 68 PHONE PHONE 206-697-B025 t/4"=1'-0" NOR-TECH FIRE PROTECTION INC. uCENSE N0.NOKTEFPo51P6 FP-2 of 3 I I 8-2V O 8-5 5-3 4-6 14-6 Mounting Bracket and No Block Hanger 2 - - 00 xl N, sse.r. 1' ,• Offset Hanger 34h 6-0 B-0 Composite Wood Joist\•e - 4-84z Headset PV 81 z Dry Sidewall 10-4 O 0 _ /Gyp.Board Ceiling Dry Sidewall CPVC HANGER DETAIL_ 99A" 94a � r 1' 1' 11-3'/z 11 4-9'z C 1 THIS SYSTEM IS DESIGNED PER SPRINKLER MANUFACTURER'S LISTING. e NB-2 Headset Mounting Bracket SEE ATTACHED CUT SHEETS FOR MANUFACTURER'S MIN. REQUIREMENTS. and No Block Hanger A TOTAL OF (4) HEADS OPERATING USING RESIDENTIAL, CONCEALED. 2 INSTALLATION TO CONFORM WITH NFPA #13R & ARLINGTON FIRE DEPT. e -- 3 ALL MATERIAL TO BE NEW, U.L. LISTED, AND PER NFPA #13. O offset Hanger 4 ALL FITTINGS TO BE CPVC U.N.O. Wood Joist 5 ALL PIPE TO BE CPVC U.N.O. CTION ALL ELECTTRICOF HEADS AL WIRING FROM OTHERS. BY OTHERS. 11-34z 11 4-91z n 13RJ Headset HYDRAULIC CALCULATIONS ARE BASED ON 16'x16'SPACING _ Gyp.Board Ceiling r r I 4-9�/z 1 I 1= / rr 12-3 I 3-8/ r r rr INSULATION DysideWall�\T,� CPVC HANGER DETAIL 99B" I - r Dry Sidewall e_p ,. 10-4 _ TRUSS AND 7_ 9 2 ,0 1 V - FIRE SPRINKLER PIPE GYPSUM WALL 3a7 (7-1 m1, 1' t' (ON WARM SIDE OF INSULATION). BOARD CEILING 5:6._ 3-Vz 8-0 O.� x 1 ___ ---�- - - SPRINKLER PIPE IN UNHEATED ATTIC Test Sprinklers.wl 30 4 _ NO SCALE e 8 2 zaz 8-5 a 5-3 a 4-6 14-6 - I I Designed Per NFPA 13R. Number of design sprinklers shall include all sprinklers within a ompanment,up to maximum of four .decent sprinklers. HYDRAULIC CALCULATIONS ARE BASED ON 16'0 B'SPACING Third Floor Plan ra = �° Hydraulic Data D FLOO AREA OF APPLICATION:NO. OF SPRINKLERS CALCULATED: 3RR COVERAGE PER SPRINKLER: 16'x16' R WASMIROTOR WrATR CERTIFICATE OF'"WETERrTF DESIGN DENSITY: 0.05 GPM&or per MFG listing = FIRE FROTECTMN SFRR4RLER SYSTEM! TOTAL AREA OF DISCHARGE: see Ian . Khosrow(David)Forananl P 1 7325-0195-C Leve13 1 Nor-Tech Fire Protection,Inc. MIN. GPM REQUIRED PER HEAD: 13 GPM 1 NORTEF 6 EI TOTAL SPRINK DEMAND AT B.O.R.61.3 GPM 68.0 PSI V a, AVAILABLE AT THE B.O.R. 61.3 GPM @ 83.7 PSI S*-t—� tzlalna R.._.............................� WATER FLOW INFORMATION: HANGER LEGEND STANDARD SYMBOLS SPRINKLER HEAD SYMBOLS MK DATE BY REVISIONS - LOCATE BY GRID COORDINATES FIELD INSPECTION BY PHONE CONTRACT WITH PROJECT 31 st Avenue Apartments Building C STATIC:90.0 PSI SPRINKLERS SYMB. MODEL ID# THREAD 'V FINISH ESCUTCH. TYPE DEGREE QTY. 1.Arlington Fire Dept. 360403-3600 GR&R Properties RESIDUAL:39.0 PSI VIKING RESIDENTIAL SPRINKLER 0 VK494 20759 Vi 49 BRASS WHITE GONG. 155 64 2. 16000 Chritemean Road#150 ADDRESS:18321 31 st Ave NE FLOW:2,575 GPM VIKING DRY SIDEWALL QUICK RESPONSE SPRK VK178 08384U 1' 56 CHIP. CHR. DSW 155' 4 3. Seattle,WA 98188 CITY Arlington,WA 98223 APPROXIMATE HYDRANT ELEVATION(ft)? 4. 805-368-9466 aD TITLE: FIRE SPRINKLER PLAN PRESSURE ZONE:XXX i x FLOW AVAILABLE 0 20 PSI,—GPM WATER DEPT. ARCHITECT ED- D.F. °me'9/8/20 co TRACT p. PITOT READING:? ncDenny rc a re TEST DATE:XXX ADDRESS 3726 Meridian Ave N NORTH e" 20030 NE Novelty Hill Road-Box B 96020 TEST LOCATION:XXX CITY CITY Seattle,WA 98103 REDMOND,WASHINGTON 98053 SHEET NO. WATER DEPARTMENT JURISDICTION:Arington SCALE: TOTAL SPRINKLERS THIS DRAWING 68 PHONE PHONE 206-697-6025 1/e"=1'-0" NOR-TECH FIRE PROTECTION INC. uCENSE No.NOKrEFP051P6 FP-3 of 3 NOR TECH' ' Hydraulic Calculations FOR: MTT Holdings 183213111 Avenue NE Arlington,WA 98223 Building"C" Design Data: Occupancy Classification: Light Hazard Standard: NFPA 13R Density: 0.05 gpm or MFG listing Area of application: Unit 34 3rd Floor Coverage of sprinklers: 16'x16'Max. Number of sprinklers calculated: (4)Heads Total Sprinkler Demand at Source: 61.3 gpm @ 68.0 psi Flow&Pressure Available at Source: 61.3 gpm @ 83.7 psi Sprinkler make& model: Viking model VK494 Residential Concealed Sprinkler Thread: ''/a"NPT Sprinkler"K" Factor: 4.9 Design Layout: D.F. Date: September 8,2020 WASHINGTON STATE � CERTIFICATE OF COWETENCT a FIRE PROTECTION SPRINKLER SYSTF Khosrow(David)Farahani vN 11 7325-0195-C Level Nor-Tech Fire Protection,Inc. NORTEFP B p uPIres i 6www.w.wwwww..wwwwwww..ww..w.� SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 Date: 09/08/2020 C: \HASS64\DATA2020\ARLINGTN\BLDG-C3R.SDF JOB TITLE: Arlington Apts . BLDG "C" 18321 31st Ave NE Arlington WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS . PRESS . @ PRESS . @ DEMAND PRESS . TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) CC 90 . 0 39 . 0 2575 . 0 89 . 9 61 . 3 74 .2 AGGREGATE FLOW ANALYSIS : TOTAL FLOW AT SOURCE 61 . 3 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0 . 0 GPM OTHER HOSE STREAM ALLOWANCES 0 . 0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 61 . 3 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 301 27 . 0 K= 4 . 90 7 . 0 13 . 0 302 27 . 0 K= 4 . 90 7 . 3 13 .2 303 27 . 0 K= 4 . 90 13 .4 17 . 9 304 27 . 0 K= 4 . 90 12 .3 17 .2 305 27 . 0 - - - - 9 . 5 - - - 306 27 . 0 - - - - 12 . 0 - - - 307 27 . 0 - - - - 12 . 7 - - - 308 27 . 0 - - - - 14 . 0 - - - 309 27 . 0 - - - - 31 . 1 - - - 300 27 . 0 - - - - 34 . 3 - - - 200 18 . 0 - - - - 39 . 9 - - - 100 8 . 7 - - - - 45 . 6 - - - 101 8 . 7 - - - - 49 . 6 - - - 102 8 . 7 - - - - 53 . 0 - - - TOR 8 . 7 - - - - 54 . 9 - - - FSO 6 . 0 - - - - 56 . 3 - - - FSI 6 . 0 - - - - 59 . 3 - - - BFO 2 . 0 - - - - 61 . 3 - - - BFI 2 . 0 - - - - 67 . 3 - BOR 1 . 0 - - - - 68 . 0 - - - UGE -3 . 0 - - - - 70 . 9 - - - WMO -3 . 0 - - - - 70 . 9 - - - WMI -3 . 0 - - - - 75 . 9 - - - CC 1 . 0 SOURCE 74 .2 61 . 3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 Date: 09/08/2020 C: \HASS64\DATA2020\ARLINGTN\BLDG-C3R.SDF JOB TITLE: Arlington Apts . BLDG "C" 18321 31st Ave NE Arlington PIPE DATA PIPE TAG Q (GPM) DIA(IN) LENGTH PRESS . END ELEV. NOZ . PT DISC. VEL (FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) F.L. /FT (PSI) Pipe: 1 -13 . 0 1 . 101 PL 8 . 16 PF 0 . 3 301 27 . 0 4 . 9 7 . 0 13 . 0 4 .4 150 FTG ---- PE 0 . 0 302 27 . 0 4 . 9 7 . 3 13 .2 0 . 031 TL 8 . 16 PV 0 . 1 Pipe: 2 -26 .2 1 . 101 PL 14 . 67 PF 2 .2 302 27 . 0 4 . 9 7 . 3 13 . 2 8 . 8 150 FTG T PE 0 . 0 305 27 . 0 0 . 0 9 . 5 0 . 0 0 . 112 TL 19 . 67 PV 0 . 5 Pipe: 3 -26 . 2 1 . 101 PL 17 .25 PF 2 .5 305 27 . 0 0 . 0 9 . 5 0 . 0 8 . 8 150 FTG T PE 0 . 0 306 27 . 0 0 . 0 12 . 0 0 . 0 0 . 112 TL 22 . 25 PV 0 .5 Pipe: 4 -26 .2 1 . 101 PL 6 . 04 PF 0 . 7 306 27 . 0 0 . 0 12 . 0 0 . 0 8 . 8 150 FTG ---- PE 0 . 0 307 27 . 0 0 . 0 12 . 7 0 . 0 0 . 112 TL 6 . 04 PV 0 . 5 Pipe: 5 -17 . 2 1 . 101 PL 2 . 83 PF 0 .4 304 27 . 0 4 . 9 12 . 3 17 .2 5 . 8 150 FTG T PE 0 . 0 307 27 . 0 0 . 0 12 . 7 0 . 0 0 . 051 TL 7 . 83 PV 0 .2 Pipe: 6 -43 .4 1 . 101 PL 4 . 75 PF 1 .4 307 27 . 0 0 . 0 12 . 7 0 . 0 14 . 6 150 FTG ---- PE 0 . 0 308 27 . 0 0 . 0 14 . 0 0 . 0 0 .285 TL 4 . 75 PV 1 .4 Pipe: 7 -17 . 9 1 . 101 PL 7 . 00 PF 0 .7 303 27 . 0 4 . 9 13 .4 17 . 9 6 . 0 150 FTG T PE 0 . 0 308 27 . 0 0 . 0 14 . 0 0 . 0 0 . 055 TL 12 . 00 PV 0 .2 Pipe: 8 -61 . 3 1 .394 PL 85 . 92 PF 17 . 1 308 27 . 0 0 . 0 14 . 0 0 . 0 12 . 9 150 FTG ET PE 0 . 0 309 27 . 0 0 . 0 31 . 1 0 . 0 0 . 171 TL 99 . 92 PV 1 . 1 Pipe: 9 -61 . 3 1 .394 PL 12 . 25 PF 3 . 1 309 27 . 0 0 . 0 31 . 1 0 . 0 12 . 9 150 FTG T PE 0 . 0 300 27 . 0 0 . 0 34 . 3 0 . 0 0 . 171 TL 18 . 25 PV 1 . 1 Pipe: 10 -61 . 3 1 .394 PL 10 . 00 PF 1 . 7 300 27 . 0 0 . 0 34 . 3 0 . 0 12 . 9 150 FTG ---- PE 3 . 9 200 18 . 0 0 . 0 39 . 9 0 . 0 0 . 171 TL 10 . 00 PV 1 . 1 Pipe: 11 -61 . 3 1 .394 PL 10 . 00 PF 1 . 7 200 18 . 0 0 . 0 39 . 9 0 . 0 12 . 9 150 FTG ---- PE 4 . 0 100 8 . 7 0 . 0 45 . 6 0 . 0 0 . 171 TL 10 . 00 PV 1 . 1 Pipe: 12 -61 . 3 1 .394 PL 17 .25 PF 4 . 0 100 8 . 7 0 . 0 45 . 6 0 . 0 12 . 9 150 FTG T PE 0 . 0 101 8 . 7 0 . 0 49 . 6 0 . 0 0 . 171 TL 23 . 25 PV 1 . 1 Pipe: 13 -61 . 3 1 . 394 PL 13 . 75 PF 3 .4 101 8 . 7 0 . 0 49 . 6 0 . 0 12 . 9 150 FTG T PE 0 . 0 102 8 . 7 0 . 0 53 . 0 0 . 0 0 . 171 TL 19 . 75 PV 1 . 1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 Date : 09/08/2020 C: \HASS64\DATA2020\ARLINGTN\BLDG-C3R.SDF JOB TITLE: Arlington Apts . BLDG "C" 18321 31st Ave NE Arlington PIPE DATA (cont . ) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS . END ELEV. NOZ. PT DISC. VEL (FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) F.L. /FT (PSI) Pipe: 14 -61 . 3 1 . 394 PL 5 . 00 PF 1 . 9 102 8 . 7 0 . 0 53 . 0 0 . 0 12 . 9 150 FTG T PE 0 . 0 TOR 8 . 7 0 . 0 54 . 9 0 . 0 0 . 171 TL 11 . 00 PV 1 . 1 Pipe: 15 -61 . 3 1 . 598 PL 3 . 00 PF 0 . 3 TOR 8 . 7 0 . 0 54 . 9 0 . 0 9 . 8 150 FTG ---- PE 1 .2 FSO 6 . 0 0 . 0 56 . 3 0 . 0 0 . 088 TL 3 . 00 PV 0 . 6 Pipe: 16 FIXED PRESSURE LOSS DEVICE FSI 6 . 0 0 . 0 59 .3 0 . 0 3 . 0 psi, 61 . 3 gpm FSO 6 . 0 0 . 0 56 .3 0 . 0 Pipe: 17 -61 . 3 1 . 598 PL 3 . 00 PF 0 .3 FSI 6 . 0 0 . 0 59 . 3 0 . 0 9 . 8 150 FTG ---- PE 1 . 7 BFO 2 . 0 0 . 0 61 . 3 0 . 0 0 . 088 TL 3 . 00 PV 0 . 6 Pipe: 18 FIXED PRESSURE LOSS DEVICE BFI 2 . 0 0 . 0 67 . 3 0 . 0 6 . 0 psi, 61 . 3 gpm BFO 2 . 0 0 . 0 61 . 3 0 . 0 Pipe: 19 -61 . 3 1 . 598 PL 3 . 00 PF 0 . 3 BFI 2 . 0 0 . 0 67 . 3 0 . 0 9 . 8 150 FTG ---- PE 0 .4 BOR 1 . 0 0 . 0 68 . 0 0 . 0 0 . 088 TL 3 . 00 PV 0 . 6 Pipe: 20 -61 . 3 1 . 598 PL 4 . 50 PF 1 . 2 BOR 1 . 0 0 . 0 68 . 0 0 . 0 9 . 8 150 FTG E PE 1 . 7 UGE -3 . 0 0 . 0 70 . 9 0 . 0 0 . 088 TL 13 . 50 PV 0 . 6 Pipe: 21 -61 . 3 6 .280 PL 70 . 00 PF 0 . 0 UGE -3 . 0 0 . 0 70 . 9 0 . 0 0 . 6 140 FTG ---- PE 0 . 0 WMO -3 . 0 0 . 0 70 . 9 0 . 0 0 . 000 TL 70 . 00 PV 0 . 0 Pipe: 22 FIXED PRESSURE LOSS DEVICE WMI -3 . 0 0 . 0 75 . 9 0 . 0 5 . 0 psi, 61 . 3 gpm WMO -3 . 0 0 . 0 70 . 9 0 . 0 Pipe: 23 -61 . 3 6 .280 PL 50 . 00 PF 0 . 0 WMI -3 . 0 0 . 0 75 . 9 0 . 0 0 . 6 140 FTG TG PE -1 . 7 CC 1 . 0 SRCE 74 . 2 (N/A) 0 . 000 TL 107 . 00 PV 0 . 0 NOTES : (1) Calculations were performed by the HASS 6 .4 . 0 computer program under license no. 4 C1324A granted by HRS Systems, Inc . 4792 LaVista Road Tucker, GA 30084 (2) The system has been balanced to provide an average imbalance at each node of 0 . 005 gpm and a maximum imbalance at any node of 0 . 105 gpm. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 Date: 09/08/2020 C: \HASS64\DATA2020\ARLINGTN\BLDG-C3R.SDF JOB TITLE: Arlington Apts . BLDG "C" 18321 31st Ave NE Arlington (3) velocity pressures are printed for information only, and are not used in balancing the system. Maximum water velocity is 14 .6 ft/sec at pipe 6 . (4) PIPE FITTINGS TABLE Pipe Table Name : CUSTOM. PIP PAGE: D MATERIAL: DIRON HWC: 140 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Ell Tee LngEll ChkVly BfyVly GatVly NPTee 6 .280 24 . 00 52 . 00 16 . 00 55 . 00 17 . 00 5 . 00 52 . 00 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R C B G A D Ell Tee T-RUN 1 . 101 7 . 00 5 . 00 1 . 00 5 . 00 6 . 00 1 . 00 10 . 00 10 . 00 1 .394 8 . 00 6 . 00 1 . 00 7 . 00 6 . 00 1 . 00 10 . 00 10 . 00 1 . 598 9 . 00 8 . 00 1 . 00 9 . 00 6 . 00 1 . 00 10 . 00 10 . 00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 Date: 09/08/2020 C: \HASS64\DATA2020\ARLINGTN\BLDG-C3R.SDF JOB TITLE: Arlington Apts . BLDG "C" 18321 31st Ave NE Arlington WATER SUPPLY CURVE 96+ *0\ 88+ \ 80+ \ X \ 72+ \ P 64+ \ R \ E \ S \ S 56+ \ U \\ R \ E \ 48+ \ P \ S \ I 40+ * <-39 . 0 psi @ 2575 gpm Flow Test Point 32+ 24+ 16+ LEGEND " X = Required Water Supply " 74 .21 psi @ 61 . 3 gpm " 8+ " 0 = Available Water Supply " 89 . 95 psi @ 61 . 3 gpm " rr 0++-+---+----+-----+------+--------+--------+---------+-----------+ 8001200 1600 2000 2400 2800 3200 3600 4000 FLOW (GPM) NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY aAPPROVED PERMIT#: AM PM DATE: OB ADDRESS: I?'3 a� 31`+ Av 4- N I= 130 C ILOT#: PROJECT: 31 't ►A ve A Pk3 TYPE OF INSPECTION: .5 P A v e,' OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE O PLANNING O CIVIL O BUILDING CITY OF ARLINGTON u NOTICE V TO PERMITEE AND/OR OWNER Cl PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED Cl DO NOT OCCUPY 71 APPROVED PERMIT#: �)'"i ��� ,❑,AM ❑ PM JDATE: OBADDRESS: Cam'��� �J I r rt �t� LOT#: PROJECT: TYPE OF INSPECTION: ? \l OTHER: vL - I U Ur% � '94 ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THEACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 A �,, INSPECTOR DATE 0 PLANNING 0 CIVIL o BUILDING CITY OF ARLINGTON (41 CITY OF ARLINGTON ` 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT L 18321 31st Avenue NE Permit#:3435Permit Expiration Date: 03/15/2021 Parcel#: 00472500000804 Valuation: 38400.00 OWNER APPLICANT _ _ CONTRACTOR MTT HOLDINGS Nor-Tech Fire Protection,Inc NOR-TECH FIRE PROTECTION 16000 CHRISTENSEN ROAD, SUITE 20030 NE Novelty Hill Rd.Box-B 20030 NE NOVELTY HILL RD 150 SEATTLE,WA 98188 Redmond,WA 98053 REDMOND,WA 98053 425-898-9111 425-898-9111 LTC:NORTEFP051 P6 EXP: 10/26/2021 MECHANICALWNTRACTOR " �` ,� PI.Ul�!IBINb CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Sprinkler CODE YEAR: 2015 STORIES: 3 CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any. other ordinance or order of the City,of any state or federal law, or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. l Signature Print Name Date Released By D to CONDITIONS 1.Permit and set of approved plans emain on site during installation.2. Significa; viations from approved plans made during installation shall be required to be resubmitted for review prior to inspections: may include hangers,earthquake bracing, sprinkler locations and pipe re-routing that could impact hydraulic calculations.Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 3. Hangers and earthquake bracing shall be installed in accordance with NFPA 13R.4.Weatherproof horn strobe to be installed in place of electric bell. 5.Hydrostatic test required:Minimum of 200 psi for 2 hours. 6. Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit.7.Final as-built drawings shall be submitted prior to close out of permit. 8. Owner shall be provided with a set of approved plans and associated documents for their files. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/21/2020 Fire Sprinkler Permit $600.00 09/21/2020 Processing/Technology Fee $25.00 09/21/2020 Fire System Plan Review $513.80 Total Due: $1,138.80 Total Payment: $0.00 Balance Due: $1,138.80 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 3435 Permit Date: 09/16/20 Permit Type: FIRE SPRINKLER Project Name: The Landing at Smokey Point Applicant Name: Nor-Tech Fire Protection, Inc Applicant Address: 20030 NE Novelty Hill Rd. Box - B Applicant, City, State, Zip: Redmond,WA 98053 Contact: Dean Olsen Phone: 425-898-9111 Email: dean@nortechfire.com Scope of Work: Fire sprinkler for multi-family building Valuation: 38400.00 Square Feet: 0 Number of Stories: 3 Construction Type: Occupancy Group: ID Code: Permit Issued: 09/22/2020 Permit Expires: 03/15/2021 Form Permit Type: Status: LASERFICHE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 125 MULTI- 00472500000804 183213 1 STAVE NE, MTT HOLDINGS FAMILY BLDG C APARTMENTS Contractors Contractor Primary Contact Phone Address Contractor Type License License# NOR-TECH FIRE 20030 NE CONSTRUCTION Construction PROTECTION Dean Olsen 425-898-9111 NOVELTY HILL CONTRACTOR Contractor NORTEFP051P6 Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 03/19/2021 Inspection Sprinkler pipe tenting 03/18/2021 03/18/2021 BUILDING Approved Plan Reviews Date Review Type Description Assigned To Review Status 09/16/2020 FIRE SPRINKLER BUILDING 1.Permit and set of approved plans to remain on site during installation. 2.Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections:may include hangers,earthquake bracing,sprinkler locations and pipe re-routing that could impact hydraulic calculations.Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 3.Hangers and earthquake bracing shall be installed in 09/16/2020 FIRE SPRINKLER accordance with NFPA 13R. FIRE 4.Weatherproof horn strobe to be installed in place of electric bell. 5.Hydrostatic test required:Minimum of 200 psi for 2 hours. 6.Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit. 7.Final as-built drawings shall be submitted prior to close out of permit. 8.Owner shall be provided with a set of approved plans and associated documents for their files. 09/16/2020 FIRE SPRINKLER no comments for this review. pW-WAT-REV Gus Fees Fee Description Notes Amount Fire Sprinkler System Commercial NFPA 13/13R $600.00 Processing/Technology $25.00 Fire System Plan Review Table 4-1 $513.80 Credit Card Service $34.16 Total $1,172.96 Attached Letters Date Letter Description 09/21/2020 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 09/21/2020 Dave Clarke 82405779 $1,138.80 09/21/2020 82405779 Raelynn Jones $34.16 Outstanding Balance $0.00 Uploaded Files Date File Name 10/07/2021 9847609-2435 IC 4.16.2021.pdf 09/24/2021 9760714-3435 IC 2.8.2021.pdf 09/24/2021 9760715-3435 IC 3.18.2021.pdf 09/22/2020 7390778-Permit 3435 18321 31 st Ave NE BLDG C 9-22-2020.pdf 09/16/2020 7357561-3435 Arlington Fire Sprinkler System Permit Application.pdf 09/16/2020 7357562-3435 Equi mn ent Specification Sheets.pdf 09/16/2020 7357559-3435 Fire Plan Arlingtion Apts BLDG C.pdf 09/16/2020 7357560-3435 Hydraulic Calculations.pdf 09/16/2020 7357328-3435 Application.pdf Date: 04/02/2026 Permit#: 3435 Permit 09/16/2020 Date: Review 09/16/2020 Date: Permit FIRE SPRINKLER Type: Review FIRE SPRINKLER Type: Target Date: 09/30/2020 Scheduled 00:00 Time: Completed 09/17/2020 Date: Description: 1. Permit and set of approved plans to remain on site during installation. 2. Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections: may include hangers, earthquake bracing, sprinkler locations and pipe re-routing that could impact hydraulic calculations. Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 3. Hangers and earthquake bracing shall be installed in accordance with NFPA 13R. 4. Weatherproof horn strobe to be installed in place of electric bell. 5. Hydrostatic test required: Minimum of 200 psi for 2 hours. 6. Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit. 7. Final as-built drawings shall be submitted prior to close out of permit. 8. Owner shall be provided with a set of approved plans and associated documents for their files. Review Status: Assigned FIRE To: Time In: 00:00 Time Out: 00:00 Hours: 1.0 Property Information Parcel#: 00472500000804 MTT HOLDINGS MTT HOLDINGS 16000 CHRISTENSEN ROAD, SUITE 150 18321 31 ST AVE NE, BLDG C SEATTLE,WA 98188 Zoning: 125 MULTI-FAMILY APARTMENTSLot: Block: CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center:360-403-3551 - BUILDING PERMIT 18321 31st Avenue NE Permit#:3435 Permit Expiration Date:03/15/2021 Parcel#: 00472500000804 Valuation:38400.00 OWNER APPLICANT CONTRACTOR MTT HOLDINGS Nor-Tech Fire Protection,Inc NOR-TECH FIRE PROTECTION 16000 CHRISTENSEN ROAD, SUITE 20030 NE Novelty Hill Rd.Box-B 20030 NE NOVELTY HILL RD 150 SEATTLE,WA 98188 Redmond,WA 98053 REDMOND,WA 98053 425-898-9111 425-898-9111 LIC:NORTF.FP051 P6 EXP: 10/26/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Sprinkler CODE YEAR: 2015 STORIES: 3 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor_The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FNAL lNSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. l Signature Print Name ate Released By D to CONDITIONS 1.Permit and set of approved plans --main on site during installation.2.Significa, viations from approved plans made during installation shall be required to be resubmitted for review prior to inspections:may include hangers,earthquake bracing, sprinkler locations and pipe re-routing that could impact hydraulic calculations.Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted.3. Hangers and earthquake bracing shall be installed in accordance with NFPA 13R.4.Weatherproof horn strobe to be installed in place of electric bell.5.Hydrostatic test required:Minimum of 200 psi for 2 hours.6. Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit.7.Final as-built drawings shall be submitted prior to close out of permit.8.Owner shall be provided with a set of approved plans and associated documents for their files. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PER'NTT`I'l E&'5 Date Description Fee Amount 09/21/2020 Fire Sprinkler Permit $600.00 09/2112020 Processing/Technology Fee $25.00 09/21/2020 Fire System Plan Review $513.80 Total Due: $1,138.80 Total Payment: S0.00 Balance Due: $1,138.80 C, LL FOR INSI'h;t"TlONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon