HomeMy WebLinkAbout8216 HUNTER PL_BLD3402_2026 NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED Cl DO NOT OCCUPY 71 APPROVED PERMIT#: AM PM IV Y DATE: '1 I c -2( 2.0 rti n JOB ADDRESS: I L l_f \ t V p IL ILOT#: PROJECT: l l(1((h(m l(r0 1 TYPE OF INSPECTION: ✓,A(I ( k 4 )1 I(� OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 Cl CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. i FOR INSPECTION CALL: 360-403-3417 I �/o INSPECTOR DATE o; I ❑PLANNING Cl CIVIL 0 BUILDING CITY OF ARLINGTON n�:�; Permit#: 3402 Permit Date: 08/28/20 Project Name: Emery Site Address: 8216 Hunter Place NE Company/Applicant Name: CM Heating, Inc. Company/Applicant Address: 1415 Broadway City, State, Zip: Everett, WA 98201 Contact: Renee Visitaction Phone: 425-259-0550 Email: renee@cmheating.com Permit Type: Residential Mechanical Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Type of Construction: VB Occupancy Type: R-3; Residential Scope of Work: Furnace and A/C Installation MIC/Opportunity Zone: Permit Issued: Permit Expires: 02/24/2021 DNU: Status: PENDING PAYMENT Property Parcel# Address Legal.Description Owner Name Owner Phone Zoning RICHARD AND I l Single Family 00874800002400 8216 HUNTER PL Residence- BEVERLY EMERY Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM Heating Inc Debbie Bauers 425-259-0550 1415 Broadway MECHANICAL Labor& CMHEAMH877DN CONTRACTOR Industries Fees Fee Description Notes Amount Inspection Fee $75.00 Air Cond. Unit-LPG Btu/h< 100>; $15.00 ., �� , I Btum>500 Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology Fee $25.00 Total $165.00 Uploaded Files Date File Name 08/28/2020 7260557-3402 A0 lic tion.& 08/28/2020 7260556-3402 EQUIPMENT SPECS."' <, _l Many L&I employees are out of the office today(Aug. 28) due to a mandatory furlough. L&I services vital to public health and safety— DOSH,electrical inspections, and workers'compensation benefits — remain operational. We will return to normal business hours on Monday. Owa,h,vo�s�,e���� Labor&Industries(httl?S://Inj.Wa,gov), C M HEATING INC Owner or tradesperson 1415 BROADWAY Principals EVERETT,WA 98201 GARNER,JAMES NICHOLAS,PRESIDENT 425-259-0550 SNOHOMISH County GARNER,KATHLEEN DIANE,SECRETARY GARNER,JAMES NICHOLAS,AGENT SMITH,PAMELA (End:01/01/1980) GARNER,PAUL MILTON,PRESIDENT (End:10/01/2012) Doing business as C M HEATING INC WA UBI No Business type 601 114 652 Corporation Governing persons JAMES GARNER PAUL M GARNER; KATHLEEN GARNER; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. CMHEAI.095R4 Effective—expiration 12124/1991—05/03/2021 Bond CBIC $12,000.00 Bond account no. 655840 Received by L&I Effective date 04/24/2002 12/01/2001 Expiration date Until Canceled Insurance American Hallmark Ins Co of Te $1,000,000.00 Policy no. 44CL603347 Received by L&I Effective date 04/21/2020 05/03/2020 Expiration date 05/03/2021 l.� 'Insurance history Savings ................ .. No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Certifications & Endorsements OMWBE Certifications No active certifications exist For this business. Apprentice Training Agent No active Washington registered apprentices exist for this business.Washington allows the use of apprentices registered with Oregon or Montana.Contact the Oregon Bureau of Labor&Industries or Montana Department of Labor &Industry to verify if this business has apprentices. Workers' Comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 490,794-01 Doing business as CHIMNEY MASTERS Estimated workers reported Quarter 2 of Year 2020"31 to 50 Workers" L&I account contact T3/NICHOLE CAROW(360)902-5634-Email:CANI235@lni.wa.gov Public Works Requirements Verify the contractor is eligible to perform work on public works projects. Required Training—Effective July 1,2019 Needs to complete training. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been'issued against this contractor. Workplace Safety& Health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/16/2015 No violations Inspection no. 317935327 Location 1415 Broadway Everett,WA 98201 i RESIDENTIAL MECHANICAL • A PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:8216 HUNTER PLACE ARLINGTON WA 98223 Project Description:INSTALLATION OF FURNACE AND AC Owner: BEVERLY EMERY Address: 8216 HUNTER PLACE City: ARLINGTON State WA Zip Code: 98223 Phone: 4255014709 Email:bjemery2@gmaii.com Applicant: CM HEATING INC Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 Phone: 4252590550 Email: RENEE@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:CM HEATING INC Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration: 5/3/2021 Phone:4252590550 Email:RENEE@CMHEAMNG.COM STAFF USE ON Y Permit #: 7/ Accepted by: Date: Received AU G 8�{t 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL 4 ,_, PERMIT APPLICATION �llg'C��O Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES �) Furnace (80+) Model #S8X2A040M3PSAA AFUE80 [� Heat Pump Model # AFUE HSPE AC Unit Model # 4A7A3024H1000N SEER 13 ❑ Freestanding Stove E j Fire Place Insert 1J; Outdoor BBQ ❑ Gas Piping [ Solid-Fuel Appliance I J1 Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: aa^ ' Date: 08/28/2020 Applicant Printed Name: RENEE VISITACION I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 AAM OO syitqda,rd HEATING & AIR CONDITIONING Submittal i i i� Split System Cooling 2.0 Ton 4A7A3024H1000N II llllllllllll, S IIIIIIIIIIIII - � [I[[[[I[[[ III llllllllllll IIIIIIIIIII II[[I[[[[ IIIII llllllllllllllll l[[[[ III IIIII [[Ill[[ (III lull [I[[[l[ I lllllllllll IIIIIII [[[[[[[[[[[[ (IIIII llllllllll [I I►II llllll I[ IIIII ll[[[[[[l[f IIII llllllllll [ _�f llllll TAG: 1 Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. December2014 4A7A3024H-SUB-1A-EN /�Ingersoller.�iv�Ra a nd UG 2 8 2020 Atice ?jv Shwdard HEATING & AIR CONDITIONING B SERVICE PANEL C ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524(5 FEET) ABOVE UNIT.UNIT SHOULD BE PLACED SO ROOF RUN-OFFWATER DOES NOT POUR DIRECTLY ON UNIT AND SHOULD BE AT LEAST 305(12")FROM WALL AND ALL SURROUNDING SHRUBBERY ONTWO SIDES, OTHERTWO SIDES UNRESTRICTED ELECTRICAL SERVICE K PANEL 25(1) ) 22.2 P/8)DIA.HOLE A LOW VOLTAGE T 28.6(1-1/8)CIA.K.O.WITH `1 22.2(7/8)CIA.HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPLY LIQUID LINE SERVICE VALVE, „E., I.D.FEMALE BRAZE CONNECTION WITH 1/4"SAE � FLARE PRESSURETAP FITTINGS G FIG.7 K.O.FOR ALTERNATE ELECTRICAL ROUTING From Dwg.D152898 GAS LINE 1/4TURN BALL SERVICE VALVE, „D„ I.D.FEMALE BRAZED CONNECTION WITH 114"SAE FLARE PRESSURE TAP FITTING.A Model Base A B C D E F G H I K 4A7A3024H 2 730 724 651 3/4 3/8 137 65 210 57 457 (28-3/4) (28-1/2) (25-5/8) (5-3/8) (2-5/8) (8-1/4) (2-1/4) (18) SOUND POWER LEVEL Model A-Weighted Sound Full Octave Sound Power[dB] Power Level[dB(A)] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A7A3024H 74 47.9 60.5 64.1 71.2 71.2 69.0 58.2 51.5 Note:Rated in accordance with AHRI Standard 270-2008 2 4A7A3024H-SUB-1 A-EN HEATING & AIR CONDITIONING Product Specifications OUTDOOR UNIT(a)(b) 4A7A3024H 1000N (a) Certified in accordance with the Air-Source Unitary Air-conditioner POWER CONNS.—V/PH/HZ(c) 208/230/1/60 Equipment certification program,which is based on AHRI standard 210/240. MIN.BIRCH.CIR.AMPACITY 18 (b) Rated in accordance with AHRI standard 270. BR.CIR.PROT.RTG.—MAX.(AMPS) 30 W Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. COMPRESSOR DURATION--SCROLL (d) This value shown for compressor RLA on the unit nameplate and on NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit VOLTS/PH/HZ 208/230/1/60 selection current. R.L.AMPS(d)—L.R.AMPS 13.5—58.3 e) No means no start components.Yes means quick start kit , components.PTC means positive temperature coefficient starter. FACTORY INSTALLED M Standard Air—Dry Coil—Outdoor (g) This value approximate.For more precise value see unit nameplate. START COMPONENTS(e) NO (h) Max.linear length 60 ft.;Max,lift—Suction 60 ft.;Max,lift—Liquid INSULATION/SOUND BLANKET NO 60 ft.For greater length consult refrigerant piping software Pub.No. COMPRESSOR HEAT NO 32-3312-0*(*denotes latest revision). OUTDOOR FAN PROPELLER DIA.(IN.)—NO.USED 18.2—1 TYPE DRIVE—NO.SPEEDS DIRECT—1 CFM @ 0.0IN.W.G.(0 2450 N O.MOTORS—HIP 1-1/8 MOTOR SPEED R.P.M. 1075 VOLTS/PH/HZ 200/230/1/60 F.L.AMPS 0.90 OUTDOOR COIL—TYPE SPINE FINT" ROWS—F.P.I. 1-24 FACE AREA(SQ.FT.) 12.89 TUBE SIZE(IN.) 3/8 REFRIGERANT LBS.—R-410A(O.D.UNIT)(g) 4 LBS.,11 OZ FACTORY SUPPLIED YES LINE SIZE—IN.O.D.GAS(h) 3/4 LINE SIZE—IN.O.D.LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10OF DIMENSIONS H X W X D CRATED(IN.) 30.1 x 26.7 x 30 WEIGHT SHIPPING(LBS.) 150 NET(LBS.) 130 4A7A3024H-SUB-1 A-E N 3 Amw?wq Shw and HEATING & AIR CONDITIONING Mechanical Specification Options General Compressor The Outdoor Units are fully charged from the factory The compressor features internal over temperature, for up to 15 feet of piping.This unit is designed to pressure protection and total dipped hermetic motor. operate at outdoor ambient temperatures as high as Other features include:Centrifugal oil pump and low 115°F.Cooling capacities are matched with a wide vibration and noise. selection of air handlers and furnace coils that are AHRI Condenser Coil certified.The unit is certified to UL 1995.Exterior is designed for outdoor application. The outdoor coil provides low airflow resistance and Casing efficient heat transfer.The coil is protected on all four sides by louvered panels. Unit casing is constructed of heavy gauge,G60 Low Ambient Cooling galvanized steel and painted with a weather-resistant powder paint on all louvered panels and prepaint on all As manufactured,this system has a cooling capacity to other panels.Corrosion and weatherproof CMBP G30 55°F.The addition of an evaporator defrost control base. permits operation to 40°F.The addition of an evaporator defrost control with TXV permits low Refrigerant Controls ambient cooling to 30°F. Refrigeration system controls include condenser fan, Thermostats—Cooling only and heat/cooling (manual compressor contactor and high pressure switch.High and automatic change over).Sub-base to match and low pressure controls are inherentto the thermostat and locking thermostat cover. compressor.A factory supplied liquid line drier is standard.Some models may require field installation. Evaporator Defrost Control —See Low Ambient Cooling. �1G Inlet tck HEATING & AIR CONDITIONING American Standard optimizes the performance of homes and buildings around the world.A business of Ingersoll Rand, the leader in creating and sustaining safe,comfortable and energy efficient environments,American Standard offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information,visit www.americanstandardair.com. American Standard has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2012 American Standard Heating&Air Conditioning 4A7A3024H-SUB-1A-EN 19 Dec 2014 / Supersedes(New) 0� Ingersoll Rand RESIDENTIAL PLUMBING APPLICATION • Community&Economic Development City of Arlington•18204 59th Ave NE•Arlington,WA 98223• Phone (360) 403-3551 This application is for new,repaired,altered or replaced plumbing installation for existing residences. Please fill out all pages of this application and include all information. The City of Arlington does not require a permit to stop leaks or clear stoppages,tuiless the piping is repaired,altered or replaced. Type of Permit: ❑ New Installation ❑ Addition/Alteration/Repair Property Address: 8216 HUNTER PLACE Project Valuation: 1200.00 Lot#: Parcel ID No.: 00874800002400 Preferred Contact: ❑Owner ®Contractor Project Description: REPLACEMENTOF 50 GALLON WATER HEATER Owner Name: BEVERLY EMERY Home No.: 4255014709 bjemery2@gmail.com Email Address: Cell No.: 4255014709 Mailing Address: 8216 HUNTER PLACE City: ARLI N GTON State: WA Zip: 98223 Contractor Name: CM HEATING I N C Office No.: 4252590550 RENEE@CMHEATING.COM Email Address: Cell No.: 4252590550 Mailing Address: 1415 BROADWAY City: EVERETT State: WA Zip: 98201 L&I Contractor License Number: C M H EAI*095R4 Expiration Date: 05/3/2021 • All hose bibs required to be equipped with Alunospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves(PRV) • Cross-Connection-Control may be required Proposed Interior Water Piping Size: ❑ 1/2 ❑ 5/s" ❑ 3/4 ❑ 1" ❑CPVC ❑ Brass ❑ PEX-AL-PEX Proposed Interior Piping Material: ❑ Copper ❑ PEX ❑ Galvanized Steel ❑ Other Proposed Exterior Water Piping Size: ❑ 1/2" ❑ 5/s" ❑ 3/a." ❑ 1" ❑ 11/2 ❑ 2" Proposed Exterior Piping Material: ❑PVC ❑ Copper ❑ PEX-AL-PEX ❑ PEX-AL-PE ❑PE ❑ PEX ❑ Other Proposed Drain-Waste-Vent(DWV) ❑ Schedule 40 ABS DWV ❑ Copper ❑ Galvanized Steel ❑ Cast Iron Material: ❑ Schedule 40 PVC DWV ❑ Brass ❑ Other Proposed Drain-Waste-Vent(DWV) ❑ 1/2 ❑ 5/s" ❑ 3/4 ❑ 1" ❑ 11/2 ❑ 2" ❑ 3" 04" Piping Size: /Z REV2.2020 Pagel of2 PLUMBING PERMIT FEES(per fixture Type of Fixture No.of Fixtures Cost per Fixture Subtotal Additional Plan Review fees x $75.00 = 0 Alteration/repair piping x $ 15.00 = 0 Backflow Assembly x $25.00 = 0 Base Plumbing Fee 1 $25.00 $25.00 Bath Shower Combo x $ 15.00 = 0 Building Main Waste x $25.00 = 0 Clothes Washer x $ 15.00 = 0 Dishwasher x $ 15.00 = 0 Drinking Fountain x $ 15.00 = 0 Floor Drains x $ 15.00 = 0 Grease Interceptor x $75.00 = 0 Grease Trap x $25.00 = 0 Hose Bibb x $ 15.00 = 0 Icemaker Refri erator x $ 15.00 = 0 Irrigation- per meter x $25.00 = 0 Kitchen Sink&Disposal x $ 15.00 = 0 Laundry Tray x $ 15.00 = 0 Lavatory x $ 15.00 = 0 Med Gas Pi in <- 5 inlets outlets x $60.00 = 0 Med Gas Piping> 5 inlets/outlets(plus:5 5 x $5.00 = 0 inlets outlets Miscellaneous- regulated by plumbing x $ 15.00 = 0 code,not otherwise specified Pretreatment Interceptor x $ 15.00 = 0 Re-inspection Fee all x $75.00 = 0 Roof Drains x $ 15.00 = 0 Shower(only) x $ 15.00 = 0 Sink bar,service,etc. x $ 15.00 = 0 Toilets x $ 15.00 = 0 Urinal x $ 15.00 = 0 Vacuum Breakers x $25.00 = 0 Water Heater 1 x $25.00 = 25 Water Heater- Tankless x $25.00 = 0 Permit Fee 50.00 Inspection Fee $75.00 Processing/Technology Fee $25.00 Total 150.00 I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington. �4a3=0 4e=a a 4 sd 4ee God= RE N E E VIS ITAC ION 8/28/2020 Signature Print Name Date FOR STAFF USE ONLY PERMIT# ACCEPTED BY: DATE STAMP REV1.2020 Page 2 of 2 4*w" s7�tffda-d. HEATING & AIR CONDITIONING Submittal Split System Cooling 2.0 Ton 4A7A3024H1000N = llllllllllll�l]]]l]l]]]llllll [[[[[[[[[[[[[[ [[[[[[[[[[[[ lllllllll [[ � l]llllll]]lllll TAG: ASAFETYWARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. December2014 4A7A3024H-SUB-1A-EN Ot# Ingersolmand l�cP�lcati! S�i . H EATING & Al R CONDITIONING B SERVICE PANEL C - ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524(5 FEET) ABOVE UNIT.UNIT SHOULD BE PLACED SO ROOF RUN-OFFWATER DOES NOT POUR DIRECTLY ON UNIT AND SHOULD BE AT LEAST 305(12")FROM WALL AND ALL SURROUNDING SHRUBBERY ONTWO SIDES. OTHERTWO SIDES UNRESTRICTED ELECTRICAL SERVICE K PANEL .8 25(1) 22.2(7/8)DIA.HOLE A LOW VOLTAGE 28.6(1-1/8)DIA.K.O.WITH 22.2(7/8)DIA.HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPLY LIQUID LINE SERVICE VALVE, H E„ I.D.FEMALE BRAZE CONNECTION WITH 1/4"SAE _ FLARE PRESSURETAP FITTINGS G FIG.1 K.O.FOR ALTERNATE ELECTRICAL ROUTING From Dwg.D152898 GAS LINE 1/4TURN BALL SERVICE VALVE, "D" I.D.FEMALE BRAZED CONNECTION WITH 1/4"SAE FLARE PRESSURE TAP FITTING.A Model Base A B C D E F G H J K 4A7A3024H 2 730 724 651 3/4 3/8 137 65 210 57 457 (28-3/4) (28-1/2) (25-5/8) (5-3/8) (2-5/8) (8-1/4) (2-1/4) (18) SOUND POWER LEVEL Model A-Weighted Sound Full Octave Sound Power[dB] Power Level[dB(A)] 63 HL_L 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A7A3024H 74 47.9 1 60.5 64.1 71.2 71.2 69.0 58.2 51.5 Note:Rated in accordance with AHRI Standard 270-2008 2 4A7A3024H-SUB-1A-EN l�cP�lcati! S�i . H EATING & Al R CONDITIONING Product Specifications OUTDOOR UNIT(a)(b) 4A7A3024H 1000N (a) Certified in accordance with the Air-Source Unitary Air-conditioner POWER CONNS.—V/PH/HZ<<) 208/230/1/60 Equipment certification program,which is based on AHRI standard 210/240. MIN.BIRCH.CIR.AMPACITY 18 (b) Rated in accordance with AHRI standard 270. BR.CIR.PROT.RTG.—MAX.(AMPS) 30 M Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. COMPRESSOR DURATION-_SCROLL (d) This value shown for compressor RLA on the unit nameplate and on NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit VOLTS/PH/HZ 208/230/1/60 selection current. R.L.AMPS(d)—L.R.AMPS 13.5—58.3 (e) No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter. FACTORY INSTALLED (f) Standard Air—Dry Coil—Outdoor (9) This value approximate.For more precise value see unit nameplate. START COMPONENTS(e) NO (h) Max.linear length 60 ft.;Max.lift—Suction 60 ft.;Max.lift—Liquid INSULATION/SOUND BLANKET NO 60 ft.For greater length consult refrigerant piping software Pub.No. COMPRESSOR HEAT NO 32-3312-0*(*denotes latest revision). OUTDOOR FAN PROPELLER DIA.(IN.)—NO.USED 18.2—1 TYPE DRIVE—NO.SPEEDS DIRECT—1 CFM @ 0.0IN.W.G.M 2450 NO.MOTORS—HP 1-1/8 MOTOR SPEED R.P.M. 1075 VOLTS/PH/HZ 200/230/1/60 F.L.AMPS 0.90 OUTDOOR COIL—TYPE SPINE FINTM ROWS—F.P.I. 1-24 FACE AREA(SQ.Fr.) 12.89 TUBE SIZE(IN.) 3/8 REFRIGERANT LBS.—R-410A(O.D.UNIT)(g) 4 LBS.,11 OZ FACTORY SUPPLIED YES LINE SIZE—IN.O.D.GAS(h) 3/4 LINE SIZE—IN.O.D.LIQ. 3/8 CHARGING SPECIFICATIONS SU BCOOLING 10O F DIMENSIONS H X W X D CRATED(IN.) 30.1 x 26.7 x 30 WEIGHT SHIPPING(LBS.) 150 NET(LBS.) 130 4A7A3024 H-SUB-1 A-E N 3 ,�l�KPr1 e'Aw �S i� H EATING & Al R CONDITIONING Mechanical Specification Options General Compressor The Outdoor Units are fully charged from the factory The compressor features internal over temperature, for up to 15 feet of piping.This unit is designed to pressure protection and total dipped hermetic motor. operate at outdoor ambient temperatures as high as Other features include: Centrifugal oil pump and low 11 VE Cooling capacities are matched with a wide vibration and noise. selection of air handlers and furnace coils that are AHRI Condenser Coil certified.The unit is certified to UL 1995.Exterior is designed for outdoor application. The outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protected on all four Casing sides by louvered panels. Unit casing is constructed of heavy gauge,G60 Low Ambient Cooling galvanized steel and painted with a weather-resistant powder paint on all louvered panels and prepaint on all As manufactured,this system has a cooling capacity to other panels.Corrosion and weatherproof CMBP-G30 55°F.The addition of an evaporator defrost control base. permits operation to 40°F.The addition of an evaporator defrost control with TXV permits low Refrigerant Controls ambient cooling to 30°F. Refrigeration system controls include condenser fan, Thermostats—Cooling only and heat/cooling (manual compressor contactor and high pressure switch. High and automatic change over).Sub-base to match and low pressure controls are inherent to the thermostat and locking thermostat cover. compressor.A factory supplied liquid line drier is standard.Some models may require field installation. Evaporator Defrost Control — See Low Ambient Cooling. oi�� �S Intertek ShW4d4vdo HEATING & AIR CONDITIONING American Standard optimizes the performance of homes and buildings around the world.A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments,American Standard offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information,visit www.americanstandardair.com. American Standard has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2012 American Standard Heating&Air Conditioning ^w,/4A7A3024H-SUB-1A-EN 19 Dec 2014 I../Ingersoll Rand Supersedes(Now) V NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY 7J APPROVED PERMIT#: �' � AM PM V DATE: OBADDRESS: PROJECT: jj c J. �1 ((Ill(t 1 1(G TYPE OF INSPECTION: t✓1 C;l (-II✓o o ( F 4 P 1 Ci OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION I THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 /D It,v INSPECTOR DAT• v o� 0 PLANNING Cl CIVIL BUILDING CITY OF ARLINGTON <�y CITY OF ARLINGTON 18204 59th Avenue NE,Arlington, WA 98223 INSPECTIONS:360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 8216 Hunter Place NE Permit#:3402 Permit Expiration Date: 02/24/2021 Parcel#: 00874800002400 Valuation: .00 OWNER APPLICANT CONTRACTOR RICHARD AND BEVERLY EMERY CM Heating,Inc. CM Heating Inc 21604 7TH AVE NE 1415 Broadway 1415 Broadway ARLINGTON, WA 98223-5065 Everett,WA 98201 Everett,WA 98201 425-259-0550 425-259-0550 LIC:CMHEAMH877DN EXP:03/15/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC It: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST. TYPE: VB DWELLING UNITS: 1 OCC GROUP: R3 BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information,or in violation of any City ordinance, regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRCI 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on Your sales return form and coded City of Arlington#3101. kkiklh -Fost2l- 8-28-2020 Signature Print Name Date Released By Date CONDITIONS PROVIDE A 3" CONCRETE SLAB WITH SEISMIC BRACING ATTACHED. PROVIDE ELECTRICAL DISCONNECT. LINES SHALL BE INSULATED AND THE USE OF ADHESIVE TAPES ARE PROHIBITED.ADHERE TO THE INSTALLATION OF APPROVED APPLIANCES.APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTIONS.CALL FOR INSPECTIONS. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. Date Description Fee Amount 08/28/2020 Inspection Fee $75.00 08/28/2020 Air Cond.Unit-LPG $15.00 08/28/2020 Forced Air Heat $25.00 08/28/2020 Mechanical Base $25.00 08/28/2020 Processingfrechnology Fee $25.00 Total Due: $165.00 Total Payment: $0.00 Balance Due: $165.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON Dw 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 -BUILDING PERMIT 8216 Hunter Place NE Permit#:3402 Permit Expiration Date: 02/24/2021 Parcel#: 00874800002400 Valuation: .00 OWNER APPLICANT a CONTRACTOR RICHARD AND BEVERLY EMERY CM Heating,Inc. CM Heating Inc 21604 7TH AVE NE 1415 Broadway 1415 Broadway ARLINGTON,WA 98223-5065 Everett,WA 98201 Everett,WA 98201 425-259-0550 425-259-0550 LIC:CMHEAMH877DN EXP:03/15/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR - LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: VB DWELLING UNITS: 1 OCC GROUP: R3 BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. fCYlftln i b eG - 8-28-2020 Signature Print Name Date Released By Date CONDITIONS PROVIDE A 3"CONCRETE SLAB WITH SEISMIC BRACING ATTACHED.PROVIDE ELECTRICAL DISCONNECT. LINES SHALL BE INSULATED AND THE USE OF ADHESIVE TAPES ARE PROHIBITED.ADHERE TO THE INSTALLATION OF APPROVED APPLIANCES.APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTIONS. CALL FOR INSPECTIONS. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. ERMIT FEES Date Description Fee Amount 08/28/2020 Inspection Fee $75.00 08/28/2020 Air Cond. Unit-LPG $15.00 08/28/2020 Forced Air Heat $25.00 08/28/2020 Mechanical Base $25.00 08/28/2020 Processing/Technology Fee $25.00 Total Due: $165.00 Total Payment: $0.00 Balance Due: $165.00 CALL FOR INSPECTIONS HIM Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 3402 Permit Date: 08/28/20 Permit Type: RESIDENTIAL MECHANICAL Project Name: Emery Applicant Name: CM Heating, Inc. Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett,WA 98201 Contact: Renee Visitaction Phone: 425-259-0550 Email: renee@cmheating.com Scope of Work: Furnace and A/C Installation Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 09/02/2020 Permit Expires: 03/01/2021 Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00874800002400 8216 HUNTER PL RICHARD AND 111 Single Family BEVERLY EMERY Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Plumbing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751 W ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION UBI 605890285 ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 09/10/2020 R00.HEAT PUMP/ 09/10/2020 09/10/2020 BUILDING Approved AC UNIT FINAL 09/10/2020 R00.FURNACE 09/10/2020 09/10/2020 BUILDING Approved FINAL Fees Fee Description Notes Amount Inspection $75.00 Air Cond.Unit-LPG Btu/h<100>; $15.00 Btu/h>500 Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Credit Card Service $4.95 Total $169.95 Attached Letters Date Letter Description 08/28/2020 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 08/31/2020 john giacomi 82025772 $165.00 08/31/2020 John Giacomi CC Surcharge Transaction $4.95 82025772 Outstanding Balance $0.00 Notes Date Note Created By: 09/01/2020 Emailed permit for signature. Kristin Foster Uploaded Files Date File Name 09/22/2021 9741577-3402 IC 9.10.2020 Final.pdf 09/02/2020 7282391-3402 Issued Permit.pdf 08/28/2020 7260556-3402 EQUIPMENT SPECS.pdf 08/28/2020 7260557-3402 Application.pdf