HomeMy WebLinkAbout18305 Woodbine Dr_BLD3100_2026 NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY APPROVED PERMIT#: __Cam- --'-J 0=' A DATE: y•�^�•2 l���� JOB ADDRESS: LOT It: PROJECT: 0 11 TYPE OF INSPECTION: i; l�'ik_C F�. 7R%L�.j& I(/ OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION v THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DAT O PLANNING o CIVIL BUILDING CITY OF ARLINGTON ��,�' CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 t . PHONE; (360) 403-3551 BUILDING PERMIT Address: 18305 Woodbine Dr Permit 4:3100 Parcel 0:00900700000500 Valuation:.00 OWNER APPLICANT CONTRACTOR Name:ELLIS SIDNEY U&MARYLIN R Nantc:Brennan llcaling Namc:Brennan floating Address: 18305 WOODBINE DR Acldress:4601 S 134th I'L Address:4601 S 1341h Place City,State Zip:ARLINGTON,WA 98223 City,State Zip:Seattle,WA 98168 City,State Zip:Seattle,WA 98168 Phone: Phone:206-248-7900 Phone:206-248-7900 LIC:BRENNIIA971R9 EXII: 12/29/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Brennan I!eating Name: Address:4601 S 1341h PL Address: City,State,Zip:Seattle,WA 98168 City,State,Zip: Phone:206-248-7900 Phone: LIC tl: BRENNHA971119 EXP: 12/29/2021 LIC 0: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWF,LLIN0 UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED TIIEREBY: NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RI:LATINO TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING Olt STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL Olt ACE 'I 11-ICAPE OF OCCUPANCY HAS BEEN GRANTED. IBC l Ill/IKCI IO. AI.F.. TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form uud cc led City Of Arlington 11. I I. i i J- ow 3 f 4 -0c "w, 3/18/2020 Signature Print Name Dale cleased Dale CONDITIONS 3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated. Use of adhesive tapes are prohibited. Adhere to approved appliance. Approved job copy shall be onsite for inspections. Call For Final inspection. THIS PERMIT AU HORIZES ONLY THE.WORK NOTED.THIS PERMIT COVI;RS WORK fO Bli DONH ON PRIVAT-PROPt{R"I'Y ONLY ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES.ETCj WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 03/18/2020 Inspection/Re-Inspection $75.00 03/18/2020 Air Cond.Unit $15.00 03118/2020 Forced Air Heat $15.00 03118/2020 Mechanical Residential Base $25.00 03/18/2020 Process!ng/Technology Fee $25.00 Total Due: $155.00 Total Payment: S().0() Balance Due: $155.00 CALL FOR INSPECTIONS BUILDING(360)403-3,117 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon 1 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community 6 Economic Development City of Arlington • 18204 59th Ave NE -Arlington,WA 98223 -Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: \-)2250 1D t- 1r c 1 '::�t LZ3 Project Description: nttx, ,p �C- c�-f ���-r aC Owner: Address: 1�1.''S.7�� W c S �C'S�t1C^ - �`� nC '(�w-) Phone: y'J'� - 1�-�Q G \G�j Email: Applicant: Brennan Heating Address: 4601 S 134th PI Seattle 98168 Phone: 206-248-790 Email: Jaimie@brennanheating.com Applicant Signatur6&: ,'/nA_,144A_--/ Electronic Signature if submitting on-line hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. CONTRACTOR INFORMATION Contractor Name:Brennan Heating Company: Brennan Heating License Number:BRENNHA971 R9 _ — Expiration: 12i29 Phone.206-248-7900 Email:Jai mie@brennan heating-corn STAFF USE O Rece1v-c Permit#: Id Accepted by: - P Date: MAR 16 2020 SPECIFICATIONS Gas Model No. EL280DF07OE36A EL28ODF09OE48B Heating Performance AHRI Ref. No. 202866990 202866991 'AFUE 80% 80% High Input-Btuh 66,000 88,000 Fire Output-Btuh 52,000 69,000 Temperature rise range-°F 30-60 35-65 Gas Manifold Pressure(in,w.g.) 3.5/ 10.0 3.5/10.0 Nat. Gas/LPG/Propane Low Input-Btuh 43,000 57,000 Fire Output-Btuh 35,000 46,000 Temperature rise range-°F 20-50 20-50 Gas Manifold Pressure(in.w.g.) 1.714.9 1.7/4.9 Nat.Gas I LPG/Propane High static-In.w,g. Heating 0.5 0.5 Cooling 0.5 0.5 Connections Flue connection-in. round 4 4 In. Gas pipe size IPS 1/2 1/2 Indoor Wheel nominal diameter x width-in. 10 x 8 10 x 10 Blower Motor output-hp 1/2 3/4 Tons of add-on cooling 1.5-3.5 3-4 Air Volume Range-cfm 400- 1475 780-1700 Electrical Voltage 120 volts-60 hertz-1 phase Data Blower motor full load amps 6.1 8.2 Maximum overcurrent protection 15 15 Shipping Data Ibs,-1 package 123 142 NOTE-Filters and provisions for mounting are not furnished and must be field provided, Annual Fuel Utilization Efficiency based on DOE lest procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces. OPTIONAL ACCESSORIES - ORDER SEPARATELY "A"Width "B"Width Models Models CABINET Downflow Combustible Flooring Base 11M59 I 11M60 CONTROLS iComfort's E30 Smart WI-FI Thermostat 15S63 15S63 Remote Outdoor Temperature Sensor X2658 X2658 Furnace Twinning Kit 16W72 16W72 DOWNFLOW FILTER KITS Downflow Filter Kit 61W06 51W07 No, and Size of filter-in. (1)20 x 20 x 1 (2)20 x 16 x 1 NIGHT SERVICE KIT Night Service Kit 17859 171359 EL28ODFE/Page 6 AMi RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community 8 Economic Development City of Arlington • 18204 59th Ave NE • Arlington,WA 98223 • Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION, Project Address: \�`�Q�j �mrl lrm r�E-• 'r- ��r 1 r-�,�,,i�c5S 1 �153 LZ3 Project Description: -6 CAS cam- _, -{ Ur-r-)a Zz Owner: C—Sl Address: \Z�,5�7�7 W tS �rn C,L T-Y Phone: �A-: - .�c�Q G�--\G �, Email: Applicant: Brennan Heating Address: 4601 S 134thh PI Seattle 98168 Phone: 206-248-79pD Email: Jaimie@brennanheating.com i ` Applicant Signatur - - - - - - - - ---- Electronic Signature if submitting on-line ! hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. CONTRACTOR INFORMATION Contractor Name:Brennan Heating Company: Brennan Heating License Number:BRENNHA971 R9 Expiration: 12129 "Q Phone:206-248-7900 Email:Jaimie@brennanheating.com ?n STAFF USE ON, """"' Permit #: I V� �IQ Accepted by: RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ ❑ Heat Pump ❑ Freestanding Stove ❑ Hydronic Piping ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System ❑ Boiler ❑ Gas Piping ❑ Storage Tank ( AC Unit ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance From Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips)are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet o Combustion ti it for l appliance-- * roper vG�i�buSiion "air and venting r@gli�i@d �o� all app • A shut-off valve is required within 6 feet of all appliances SPECIFICATIONS Gas Model No. EL28ODF07OE36A I EL28ODF09OE48B Heating Performance AHRI Ref, No. 202866990 202866991 'AFUE 60% 80% High Input-Btuh 66,000 88,000 Fire Output-Btuh 52,000 69,000 Temperature rise range-°F 30-60 35-65 Gas Manifold Pressure(in, w.g,) 3.5/ 10.0 3.5/10.0 Nat. Gas/LPG/Propane Low Input-Btuh 43,000 57,000 Fire Output-Btuh 35,000 46,000 Temperature rise range-°F 20-50 20-50 Gas Manifold Pressure(in.w.g.) 1.7/4.9 1.7/4.9 Nat. Gas/LPG/Propane High static-in.w.g. Heating 0.5 0.5 Cooling 0.5 0.5 Connections Flue connection-in. round 4 4 In. Gas pipe size IPS 1/2 1/2 Indoor Wheel nominal diameter x width-in. 10 x 8 10 x 10 Blower Motor output-hp 1/2 3/4 Tons of add-on cooling 1.5-3.5 3-4 Air Volume Range-c6r 400-1475 780-1700 Electrical Voltage 120 volts-60 hertz-1 phase Data Blower motor full load amps 6,1 8,2 Maximum overcurrent protection 15 15 Shipping Data Ibs,-1 package 123 142 NOTE-Fillers and provisions for mounting are not furnished and must be field provided, Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized fumaces. OPTIONAL ACCESSORIES - ORDER SEPARATELY "A"Width "B"Width Models Models CABINET Downflow Combustible Flooring Base I 11M59 I 11M60 CONTROLS iCorri E30 Smart WI-FI Thermostat 15S63 15863 Remote Outdoor Temperature Sensor X2658 X2658 Furnace Twinning Kit 16W72 16W72 DOWNFLOW FILTER KITS Downflow Filter Kit I 51 W06 51 W07 No. and Size of filter-in.f (1)20 x 20 x 1 (2)20 x 16 x 1 NIGHT SERVICE KIT Night Service Kit J 17B59 171359 EL28ODFE/Page 6 SPECIFICATIONS 4 General Model No. All Regions EL16XC1.018 EL16XCl-024 EL16XC1-030 EL16XC1-036 Data Southeast and North Regions --. --- --- EL16XCl SO36 Nominal Tonnage 1.5 2 2.5 3 Connections Liquid line(o,d.)-in. 318 3/8 3/8 3/8 (sweat) Suction line(c.d.)-in. 3/4 3/4 3/4 718 Refrigerant 'R-410A charge furnished 4 lbs. 9 oz. 4 lbs. 9 oz. 5 lbs.8 oz. 8 Ibs. 0 oz. Outdoor Net face area-sq. ft. Outer coil 13.22 16.33 21.00 18.67 Coil Inner coil --- --- --- 17.96 Tube diameter-in, 5/16 5/16 5116 5/16 No. of rows 1 1 1 2 Fins per inch 26 26 26 22 Outdoor Diameter-in, 18 22 22 22 Fan No, of blades 3 3 3 3 Motor hp 1/10 1/6 1/6 1/6 Cfrn 2290 3160 3160 3160 Rpm 1075 825 1 825 825 Watts 160 215 215 190 Shipping Data-lbs.1 pkg. 155 171 187 220 ELECTRICAL DATA Line voltage data-60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph Maximum overcurrent protection(amps) 20 25 25 30 Minimum circuit ampacity 11.9 14,6 17 18.5 Compressor Rated load amps 9.0 10.9 12.8 14.1 Locked rotor amps 48 59.3 67.8 83 Power factor 0.97 0.97 0.97 0.96 Outdoor Fan Motor Full load amps 0.7 1 1 1 Locked rotor amps 1.3 1.9 1.9 1.9 CONTROLS IComforr E30 Smart WI-FI Thermostat 15S63 Remote Outdoor Temperature Sensor X2668 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 Compressor Hard Copeland 10J42 Start Kit LG 88M91 Compressor Low Ambient Cut-Off Switch 45F08 Compressor Timed-Off Control 47J35 Freezestat 318 in.tubing 931335 5/8 in, tubing 50A93 Indoor Blower Off Delay Relay 58M81 Loss of Charge Switch Kit 84M23 Low Ambient Kit(Fan Cycling) 34M72 Refrigerant L15-41-20 L15-41-40 Line Sets L15-41-30 L15-41-50 L15-65-30 1-15-65-40 L 15-65-50 NOTE-Extremes of operating range are plus 10%and minus 5%of line voltage. Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. HACR type breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. 'Crankcase Heater and Freezestat are recommended with Low Ambient Kit. EL16XC1 •1.5 to 5 Ton Air Conditioner /Page 7 ARIML RESIDENTIAL MECHANICAL IV PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: O r Project Description: \ Owner: 't5-\ , Address: Phone: y'� - �1 q Q - q�-\�► r; Email: Applicant: Brennan Heating Address: 4601 S 134th PI Seattle 98168 Phone: 206-248-79 Email: Jaimie@brennanheating.com Applicant Signature: Electronic Signature if submitting on-line ! hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. CONTRACTOR INFORMATION Contractor Name:Brennan Heating Company: Brennan Heating License Number.BRENNHA971 R9 Expiration: 12/29 a Phone:206-248-7900 Email:Jaimie@brennanheating.com STAFF USE ONLY Permit#: Accepted by: Date: RESIDENTIAL MECHANICAL PERMIT APPLICATION 40 Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington,WA 98223 • Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Fireplace Insert ❑ Outdoor BBQ ❑ Heat Pump ❑ Freestanding Stove ❑ Hydronic Piping ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System ❑ Boiler ❑ Gas Piping ❑ Storage Tank AC Unit ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: " Pipe Material: Pipe Size: Distance From Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances SPECIFICATIONS Gas Model No. EL28ODF07OE36A EL28ODF09OE48B Heating Performance AHRI Ref. No. 202866990 202866991 'AFUE 80% 80% High Input-Btuh 66,000 88,000 Fire Output-Btuh 52.000 69,000 Temperature rise range-°F 30-60 35-65 Gas Manifold Pressure(in,w.g.) 3.5/ 10.0 3.5/10.0 Nat. Gas/LPG/Propane Low Input-Btuh 43,000 57,000 Fire Output-Btuh 35,000 46,000 Temperature rise range-°F 20-50 20-50 Gas Manifold Pressure(in.w.g.) 1.7/4.9 1.7/4.9 Nat.Gas/LPG/Propane High static -in.w.g. Heating 0.5 0.5 Cooling 0.5 0.5 Connections Flue connection-in. round 4 4 in. Gas pipe size IPS 1/2 1/2 Indoor Wheel nominal diameter x width-in. 10 x 8 10 x 10 Blower Motor output-hp 1/2 3/4 Tons of add-on cooling 1.5-3.5 3-4 Air Volume Range-cfrn 400- 1475 780- 1700 Electrical Voltage 120 volts-60 hertz- 1 phase Data Blower motor full load amps 6.1 8.2 Maximum overcurrent protection 15 15 Shipping Data lbs.- 1 package 123 142 NOTE-Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces. OPTIONAL ACCESSORIES - ORDER SEPARATELY "A"Width "B"Width Models Models CABINET Downflow Combustible Flooring Base I 11 M59 11 M60 CONTROLS iComforC E30 Smart Wi-Fi Thermostat 15S63 15363 Remote Outdoor Temperature Sensor X2658 X2658 Furnace Twinning Kit 16W72 16W72 DOWNFLOW FILTER KITS Downflow Filter Kit 51WO6 51W07 No. and Size of filter-in. (1)20 x 20 x 1 (2)20 x 16 x 1 NIGHT SERVICE KIT Night Service Kit I 1712159 17B59 EL28ODFE/Page 6 SPECIFICATIONS General Model No. All Regions EL16XC1-018 EL16XC1-024 EL16XC1-030 EL16XC1-036 Data Southeast and North Regions --- --- --- EL16XClSO36 Nominal Tonnage 1.5 2 2.5 3 Connections Liquid line(o.d.)-In. 3/8 3/8 3/8 3/8 (sweat) Suction line(o.d.)-In. 3/4 3/4 3/4 7/8 Refrigerant R-410A charge furnished 4 lbs. 9 oz. 4 lbs. 9 oz, 5 lbs. 8 oz. 8 lbs. 0 oz. Outdoor Net face area-sq. ft. Outer coil 13.22 16.33 21.00 18.67 Coil Inner coil --- --- --- 17.96 Tube diameter-in. 5/16 5/16 5/16 5/16 No. of rows 1 1 1 2 Fins per inch 26 26 26 22 Outdoor Diameter-in, 18 22 22 22 Fan No, of blades 3 3 3 3 Motor hp 1/10 1/6 1/6 1/6 Cfrn 2290 3160 3160 3160 Rpm 1075 825 825 825 Watts 160 215 215 190 Shipping Data -lbs. 1 pkg. 155 171 187 220 ELECTRICAL DATA Line voltage data -60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph ' Maximum overcurrent protection (amps) 20 25 25 30 ' Minimum circuit arnpacity 11.9 14.6 17 18.6 Compressor Rated load amps 9.0 10.9 12.8 14.1 Locked rotor amps 48 59.3 67.8 83 Power factor 0.97 0.97 0,97 0.96 Outdoor Fan Motor Full load amps 0.7 1 1 1 Locked rotor amps 1.3 1.9 1.9 1.9 CONTROLS iComfort` E30 Smart Wi-Fi Thermostat 15S63 Remote Outdoor Temperature Sensor X2658� OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 Compressor Hard Copeland 1OJ42 Start Kit LG 88M91 Compressor Low Ambient Cut-Off Switch 45F08 Compressor Timed-Off Control 47,135 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Indoor Blower Off Delay Relay 58M81 Loss of Charge Switch Kit 84M23 Low Ambient Kit(Fan Cycling) 34M72 Refrigerant L15-41-20 L15-41-40 Line Sets L15-41-30 L15-41-50 L15-65-30 L15-65-40 L 15-65-50 NOTE-Extremes of operating range are plus 10%and minus 5%of line voltage. Refrigerant charge sufficient for 15 ft.length of refrigerant Imes.For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. HACR type breaker or fuse. 'Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. Crankcase Heater and Freezestat are recommended with Low Ambient Kit. EL16XC1 - 1.5 to 5 Ton Air Conditioner /Page 7 NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL Cl CORRECTIONS REQUIRED ❑ DO NOT OCCUPY RfAPPROVED PERMIT#: - DATE: Lo•�� OB ADDRESS: �jX7 7_ ,)C_ LOT#: PROJECT:�j I I S I TYPE OF INSPECTION: '�L I%itL��. fi1)KdihL L It/ OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT Cl CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK I ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. A 4 ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE(PER IBC) E MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 r INSPECTOR DATE O PLANNING O CIVIL BUILDING CITY OF ARLINGTON ' ' CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:18305 Woodbine Dr Permit#:3100 Parcel#:00800700000500 Valuation:.00 OWNER) M APPLICANT CONTRACTOR Name:ELLIS SIDNEY U&MARYLIN R Name:Brennan Heating Name:Brennan Heating Address: 18305 WOODBINE DR Address:4601 S 134th PL Address:4601 S 134th Place City,State Zip:ARLINGTON,WA 98223 City,State Zip:Seattle,WA 98168 City,State Zip:Seattle,WA 98168 Phone: Phone:206-248-7900 Phone:206-248-7900 LIC:BRENNHA971R9 EXP: 12/29/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Brennan Heating Name: Address:4601 S 134th PL Address: City,State,Zip:Seattle,WA 98168 City,State,Zip: Phone:206-248-7900 Phone: LIC#:BFENNHA97IR9 EXP: 12/29/2021 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 3/18/2020 Signature Print Name Date eleased Date _ CONDITIONS -0' 3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated. Use of adhesive tapes are prohibited. Adhere to approved appliance. Approved job copy shall be onsite for inspections. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 03/18/2020 Inspection/Re-Inspection $75.00 03/18/2020 Air Cond. Unit $15.00 03/18/2020 Forced Air Heat $15.00 03/18/2020 Mechanical Residential Base $25.00 03/18/2020 Processing/Technology Fee $25.00 Total Due: $155.00 Total Payment: $0.00 Balance Due: $155.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 02 PHONE; (360)403-3551 BUILDING PERMIT Address: 18305 Woodbine Dr Permit#:3100 Parcel#:00800700000500 Valuation:.00 OWNER APPLICANT CONTRACTOR Name:ELLIS SIDNEY U&MARYLIN R Name:Brennan I Icating Names Brennan heating Address: 18305 WOODBINE DR Address:4601 S 134th PL Address:4601 S 1341h Place City,State Zip:ARLINGTON,WA 98223 City,State Zip:Seattle,WA 98168 City,State Zip:Seattle,WA 98168 Phone: Phone:206-248-7900 Phone:206-248-7900 LIC:BRENNI IA971 R9 EXP: 12/29/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Brennan Ileating Name: Address:4601 S 134th PL Address: City,State,'Zip:Seattle,WA 98168 City,State,'Zip: Phone:206-248-7900 Phone: LIC#:BRENNHA971 R9 EXP: 12/29/2021 LIC t: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY: NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR ACE TIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI l0/IRC110. A E TAX NOTICE:Salcs tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form (and c ed City Of Arlington It.1 1. i w 3 jq �o M4,41 3/18/2020 Signature Print Name Date 4, elcased Date CONDITIONS 3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated. Use of adhesive tapes are prohibited. Adhere to approved appliance. Approved job copy shall be onsite for inspections. Call for final inspection. THIS PERMIT AUTHORIZES ONLY T11E WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 03/18/2020 Inspection/Re-Inspection $75.00 03/18/2020 Air Cond.Unit $15.00 03/18/2020 Forced Air Heat $15.00 03/18/2020 Mechanical Residential Base $25.00 03/18/2020 Processing/Technology Fee $25.00 Total Due: S155.00 Total Payment: S0.00 Balance Due: $155.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 3100 Permit Date: 03/18/20 Permit Type: RESIDENTIAL MECHANICAL Project Name: Ellis Applicant Name: Brennan Heating Applicant Address: 4601 S 134th PL Applicant, City, State, Zip: Seattle,WA 98168 Contact: Jaimie How Phone: 206-248-7900 Email:jaimie@brennanheating.com Scope of Work: Install new A/C and gas furnace Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 03/19/2020 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00800700000500 18305 WOODBINE DR ELLIS SIDNEY U& 111 Single Family MARYLIN R Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL COA 602 346 866 CONTRACTOR Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL Labor and BRENNHA971R9 CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 06/22/2020 R00.HEAT PUMP/ 06/22/2020 06/22/2020 BUILDING Approved AC UNIT FINAL 06/22/2020 R00.FURNACE 06/22/2020 06/22/2020 BUILDING Approved FINAL Fees Fee Description Notes Amount Inspection $75.00 Air Cond.Unit Btu/h< 100>; $15.00 Btu/hp>500 Forced Air Heat fee per Btu $15.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Credit Card Service $4.65 Total $159.65 Attached Letters Date Letter Description 03/18/2020 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 03/18/2020 Brennan Heating 79564140 $155.00 03/18/2020 79564140 CC Surcharge Raelynn Jones $4.65 Outstanding Balance $0.00 Uploaded Files Date File Name 09/24/2021 9760280-3100 IC 6.22.2020.pdf 03/18/2020 6404383-3100 Application.pdf