Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17730 31st Dr Ne_BLD3090_2026
NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY XAPPROVED PERMIT#:-DD- V-1v"i AM M DATE: ��� Z02-0 JOB ADDRESS: �"I�I ���'� G, LOT#: PROJECT: W tl IT<_Irr TYPE OF INSPECTION: I vv_..In " OTHER: Cl NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVEARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 l INSPECTOR DATE Cl PLANNING Cl CIVIL -1 BUILDING CITY OF ARLINGTON '. 0 0 CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:17730 31st DR NE Permit#:3090 Parcel#:00621300003000 Valuation:.00 OWNER APPLICANT CONTRACTOR Name:WHITESITT CARMEN Name:Blue Flame Heating&Air Name:BLUE FLAME HEATING AND AIR Address:17730 31 ST DR NE Address:7116 220th St SW#1 Address:7116 220 ST SW City,State Zip:ARLINGTON,WA 98223 City,State Zip:Mountlake Terrace,WA 98043 City,State Zip:Mountlake Terrace,WA 98043 Phone: Phone:425-771-7139 Phone:425-771-7139 LIC:BLUEFFH825RM EXP: 12/31/2020 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,Stale,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID, IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1l0fIRC110. SALF,STAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded Cit o Arlington#3101. 3/10/2020 ignature Print Name Date Release VyDate CONDITIONS Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 03/10/2020 Inspection/Re-Inspection $75.00 03/10/2020 Forced Air Heat $15.00 03/10/2020 Mechanical Residential Base $25.00 03/10/2020 ProcessingfTechnology Fee $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon +i I r: RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:17730 31TH DR NE Project Description:MECHANICAL Owner: CARMEN WHITESITF Address: 17730 31TH DR NE City: ARLINGTON State WA Zip Code: 98223 Phone: 425-418-7283 Entail:INFO@ BLU E FLAM EC OM FORT.0 OM Applicant: GEORGINA BARRIOS Address: 7116 220TH STSW STE 1 City: MOUNTLAKE StateYVA Zip Code: 98043 Phone: 425-771-7139 Email: INFO@ BLUE FLAM EC OM FORT.0 OM CONTRACTOR INFORMATION Contractor Name:BLUE FLAME HEATING AND AIR Address: 7116 220TH STSW STE 1 City: MOUNTLAKE State WA Zip Code: 98043 License Number:BLUEFFH825RM Expiration: 12-31-20 Phone:425-771-7139 Email:IN FO@ BLU E FLAM E C OM FORT.0 OM ReCeIVe, STAFF USE ON Y Permit#: y; 1/`� (� Accepted by: Date: 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES �j Furnace (80+) Model #S8X1A040M3PSAA AFUE ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER Q1 Freestanding Stove 0! Fire Place Insert D Outdoor BBQ L-Ji Gas Piping Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: U! Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date: 03/09/2020 Applicant Printed Name: GEORGINA BARRIOS I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 I 3 Ton, 1 Stage,80%,40K BTU Furnace, 14.5 in Wide(Up/Down/Horiz/L or R),ECM Motor-American Standard® S8X1A040M31PSAA Item#:S8X1 A040M3PSAA MFR:S8X1A040M3PSAA Available DESCRIPTION Upflow/Downflow/Horizontal Gas Furnace,80%AFUE Rated,Silicon Nitride Hot Surface Igniter,High Efficiency Blower Motor,34 X 14.5 X 28.75 SPECIFICATIONS AFUE Rating 80% Connedion Size 1/2 in Dimensions 34 in H x 14.5 in W x 28.75 in D Fuse Size 24 Gas Type Natural Gas;LP Gas Ignition Type Silicon Nitride Hot Surface Igniter Input Capacity 40,000 Btu/hr Material Heavy Steel Motor Rating 1/2HP Motor Type High Efficiency Blower Motor Output Capacity 32,000 Btu/hr Series S8X1 Type Upflow/Downflow/Horizontal Gas Furnace Voltage Rating 115 VAC Warranty 20 Year(Heat Exchanger);10 Year(Internal Functional Parts) FEATURES Features and Benefits 80%AFUE 34 INCH TALL Lighter,easier to move and fit into tight spaces like tight closets 4-WAY MULTI-POISE Upflow/Downflow/Horizontal Left/Horizontal Right INTEGRATED FURNACE CONTROL Setup/Status/Diagnostics/Digital Display 1 No dip switches Last six errors stored TUBULAR ALUMINIZED STEEL HEAT EXCHANGER Hi there, have a question?Text us here. I wa,nmyio�smi�om�nm-i or Labor&Industries(IbEos1/IInima.gpv), BLUE FLAME HTG AIR & ELECTRIC Owner or tradesperson 965 RIDGE LAKE BLVD. Principals SUITE 201 KARNES,DONALD KEITH,MANAGER MEMPHIS,TN 38120 901-271-9700 ■ SLOTT,DAVID MICHAEL,MANAGER ■ ORBEGOSO,LUIS,MANAGER ■ MCMAHON,JAMES THOMAS,MANAGER Doing business as BLUE FLAME HTG AIR&ELECTRIC WA UBI No. Business type 601 837 949 Limited Liability Company Governing persons BILL YOUNG DAVE SLOTT; DAVID M SLOTT, DONALD K KARNES; HOLDINGS AIRS ACQUISITION; JAMES T MCMAHON; JIM MCMAHON; LUIS ORBEGOSO; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. BLUEFFH825RM Effective—expiration 12/31/2018-12/31/2020 Bond Westchester Fire Insurance Company $12,000.00 Bond account no. K15776109 Received by L&I Effective date 12/11/2018 12/04/2018 Expiration date Until Canceled Insurance Liberty Mutual Fire Insurance $2,000,000.00 Policy no TB2631508631029 Received by L&I Effective date 09/24/2019 10101/2019 Expiration date 10/01/2020 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings ....... ................ No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contr- nr license during the previous 6 year period,but some Nts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training.Agent No active Washington registered apprentices exist for this business.Washington allows the use of apprentices registered with Oregon or Montana.Contact the Oregon Bureau of Labor&Industries or Montana Department of Labor &Industry to verify if this business has apprentices. Workers' Comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. This company has multiple workers'comp accounts. Active accounts L&I Account ID Account is current. 139,244-00 Doing business as AIRS RESCUE ROOTER Estimated workers reported Quarter 4 of Year 2019"Greater than 100 Workers" L&I account contact T2/LINDA ALGUIRE(360)902-4678-Email:POTH235@lni.wa.gov Track this contractor v Public Works Requirements Verify the contractor is eligible to perform work on public works projects. Required Training—Effective July_1_,2019 Exempt from this requirement. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace Safety& Health Check for any past safety and health violations found on jobsites this business was responsible for. No inspections during the previous 6 year period. �_y Q. RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 17730 31TH DR NE Project Description:MECHANICAL Owner: CARMEN WHITESITT Address: 17730 31TH DR NE City: ARLINGTON State.WA Zip Code: 98223 Phone: 425-418-7283 Email:INFO@BLUEFLAMECOMFORT.COM Applicant: GEORGINA BARRIOS Address. 7116 220TH STSW STE 1 City. MOUNTLAKE StateYVA Zip Code: 98043 Phone. 425-771-7139 Email. INFO@BLUEFLAMECOMFORT.COM CONTRACTOR INFORMATION Contractor Name:BLUE FLAME HEAl1NG AND AIR Address: 7116 220TH STSW STE 1 City: MOUNTLAKE State WA Zip Code: 98043 License Number: BLUEFFH825RM Expiration: 12-31-20 Phone: 425-771-7139 Email:INFO@ BLU EFLAMECOMFORT.COM STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #S8X1A040M3PSAA AFUE ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances � ��� Applicant Signature: Date: 03/09/2020 Applicant Printed Name: GEORGINA BARRIOS I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:17730 31st DR NE Permit#:3090 Parcel#:00621300003000 Valuation:.00 OWNER APPLICANT CONTRACTOR Name:WHITESITT CARMEN Name:Blue Flame Heating&Air Name:BLUE FLAME HEATING AND AIR Address: 17730 31ST DR NE Address:7116 220th St SW#1 Address:7116 220 ST SW City,State Zip:ARLINGTON,WA 98223 City,State Zip:Mountlake Terrace,WA 98043 City,State Zip:Mountlake Terrace,WA 98043 Phone: Phone:425-771-7139 Phone:425-771-7139 LIC:BLUEFFH825RM EXP: 12/31/2020 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRCI 10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded Ci o Arlington#3101. W f rt6- �� rr� 3/10/2020 ignature Print Name Date Release Date CONDITIONS Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 03/10/2020 Inspection/Re-Inspection $75.00 03/10/2020 Forced Air Heat $15.00 03/10/2020 Mechanical Residential Base $25.00 03/10/2020 Processing/Technology Fee $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:17730 31st DR NE Permit#:3090 Parcel#:00621300003000 Valuation:.00 OWNER M APPLICANT r CONTRACTOR T Name:WHITESITT CARMEN Name:Blue Flame Heating&Air Name:BLUE FLAME HEATING AND AIR Address: 17730 31 ST DR NE Address:7116 220th St SW#1 Address:7116 220 ST SW City,State Zip:ARLINGTON,WA 98223 City,State Zip:Mountlake Terrace,WA 98043 City,State Zip:Mountlake Terrace,WA 98043 Phone: Phone:425-771-7139 Phone:425-771-7139 LIC:BLUEFFH825RM EXP: 12/31/2020 MECHANICAL CONTRACTOR PLUMBING CONTRACTORM Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION MW .in PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 3/10/2020 Signature Print Name Date Release y Date CONDITIONS Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 03/10/2020 Inspection/Re-Inspection $75.00 03/10/2020 Forced Air Heat $15.00 03/10/2020 Mechanical Residential Base $25.00 03/10/2020 Processing/Technology Fee $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIO I -A - BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon BUILT TO A HIGHER STANDARD' Amm?w s*Idwd. HEATING & AIR CONDITIONING S9V2-VC _ Two Stage ECM Variable Speed Table FUR-1-A-S9V2-VS Variable Speed,2 Stage,Direct/Non-Direct Vent,Upflow/Horizontal Left/Horizontal Right Condensing Gas Furnace with Variable Speed Draft Inducer(120/1/60)(D Airflow Flue Uncrated Shipping ® Unit In Output(Btuh) ICS) Size Ignition Dimensions(in.) Weight Max Filter Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (lbs.) Fuse* Sizes** S9V2BO4OU3VSAB 3 39,141 25,639 97.000 2,3,4 ® 34 x 171/2 x 283/4 122 15 16 x 25 x 1 ® S9V2130601JI3VSAB 3 57,838 38,271 97.0® 2,3,4 ® 34 x 171/2 x 283/4 127 15 16 x 25 x 1 El p S9V2BO8OU3VSAB 3 77,259 51,003 97.0® 2,3,4 ® 34 x 171/2 x 283/4 132 15 16 x 25 x 1 ,0: M2C10004VSAB 4 96,362 64,036 97.00 2,3,4 ® 34 x 21 x 283/4 154 15 20 x 25 x 1 Q ® s S9V2D120U5VSAB 5 113,145 76,668 97.0(D 3,4 ® 34 x 241/2 x 283/4 167 15 24 x 25 x 1 S9V2-VS Direct Vent Upflow Table FUR-1-13-S9V2-VS Variable Speed,2 Stage,Direct/Non-Direct Vent,Downflow Condensing Gas Furnace (120/1/60)O Airflow Flue Uncrated Shipping ® ® Unit In Output(Btuh) ICS() Size Ignition Dimensions(in.) Weight Max Filter Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (lbs.) Fuse* Sizes** 0 ° S9V2BO8OD3VSAB 3 76,363 51,091 97.0® 2,3,4 ® 34 x 171/2 x 283/4 132 15 (2)14 x 20 x 1 o• S9V2C100D4VSAB 4 95,833 63,950 97.0( 2,3,4 ® 34 x 21 x 283/4 154 15 (2)16 x 20 x 1 Note:Variable Speed furnaces should not be twinned and are not approved for twinning applications. OO Isolated Combustion System. AFUE may vary based on poise. (� (D Energy Star. 0, o ®Direct drive variable speed motor is an ECM constant airflow blower motor. ® ® ®Silicon Nitride Igniter. S9V2-VS * Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. **Filters are not shipped with furnace. For Upflow furnaces,the size is for a bottom return filter. Direct Vent Downflow S9V2 - Two Stage ECM Variable Speed Table FUR-1-C-SM Variable Speed,2 Stage,Direct/Non-Direct Vent,Upflow/Horizontal Left/Horizontal Right Condensing Gas Furnace(120/1/60)O Airflow Flue Uncrated Shipping ® ® Unit In Output(Btuh) ICSO Size Ignition Dimensions(in.) Weight Max Filter p Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (lbs.) Fuse* Sizes** S9V2BO4OU3PSBB 3 38,800 25,220 96.0( 2,3,4 ® 34 x 171/2 x 283/4 122 15 16 x 25 x 1 �. S9V2B060U3PSB6 3 58,200 37,830 96.000 2,3,4 ® 34 x 171/2 x 283/4 127 15 16 x 25 x 1 0* M213060WSBB 4 58,200 37,830 96.002 2,3,4 ® 34 x 171/2 x 283/4 130 15 16 x 25 x 1 0 ° S9V2B080U3PSBB 3 77,600 50,440 96.0® 2,3,4 ® 34 x 171/2 x 283/4 132 15 16 x 25 x 1 S9V2B080U4PSBB 4 77,600 50,440 96.0()O 2,3,4 ® 34 x 17'/2 x 283/4 135 15 16 x 25 x 1 S9V2C080U5PSBB 5 77,600 50,440 96.000 2,3,4 ® 34 x 21 x 283/4 149 15 20 x 25 x 1 SM S9V2C10004PSBB 4 97,000 63,050 96.002 2,3,4 ® 34 x 21 x 283/4 154 15 20 x 25 x 1 Direct Vent Upflow S9V2C10005PSBB 5 97,000 63,050 96.0® 2,3,4 ® 34 x 21 x 283/4 155 15 20 x 25 x 1 S9V2D12OU5PSBB 5 116,400 75,660 96.0()O 3,4 ® 34 x 241/2 x 283/4 167 15 24 x 25 x 1 Table FUR-1-D-S9V2 Variable Speed,2 Stage,Direct/Non-Direct Vent,Downflow Condensing Gas Furnace (120/1/60)O Airflow Flue Uncrated Shipping ® ® Unit In Output(Btuh) ICS() Size Ignition Dimensions(in.) Weight Max Filter .0. °. Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (lbs.) Fuse* Sizes** o S9V2BO4OD3PSBB 3 38,800 25,220 96.0® 2,3,4 ® 34 x 171/2 x 283/4 122 15 (2)14 x 20 x 1 ® S9V2BO6OD3PSBB 3 58,200 37,830 96.000 2,3,4 ® 34 x 171/2 x 283/4 127 15 (2)14 x 20 x 1 S9V2B080D3PSBB 3 77,600 50,440 96.0( 2,3,4 ® 34 x 171/2 x 283/4 132 15 (2)14 x 20 x 1 S9V2B080D4PSBB 4 77,600 50,440 96.00 2,3,4 ® 34 x 171/2 x 283/4 135 15 (2)14 x 20 x 1 L0' S9V2C100D4PSBB 4 97,000 63,050 96.00 2,3,4 ® 34 x 21 x 283/4 154 15 (2)16 x 20 x 1 S9V2C100D5PSBB 5 97,000 63,050 96.00 2,3,4 ® 34 x 21 x 283/4 155 15 (2)16 x 20 x 1 S9V2 S9V2D12OD5PSBB 5 116,400 75,660 96.00 3,4 ® 34 x 241/2 x 283/4 167 15 (2)16 x 20 x 1 Direct Vent Note:Variable speed furnaces should not be twinned and are not approved for twinning applications. Downflow O Isolated Combustion System. AFUE may vary based on poise. ®Energy Star. ®Direct drive variable speed motor is an ECM constant airflow blower motor. ®Silicon Nitride Igniter. * Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. **Filters are not shipped with furnace. For Upflow furnaces,the size is for a bottom return filter. For complete equipment/combination selections, installation instructions and warranty information, Effective 1/1/19 please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-1 14-1011-36 BUILT TO A HIGHER STANDARD" Amler iw S7�tffdmd® HEATING & AIR CONDITIONING S9X2 _ Two Stage High Efficiency ECM Table FUR-2-A-S9X2 5 Speed High Efficiency ECM Motor,2 Stage,Direct/Non-Direct Vent,Upflow/Horizontal Left/Horizontal Right Condensing Gas Furnace(120/1/60)O Airflow Flue Uncrated Shipping ® (D Unit In Output(Btuh) ICSO Size Ignition Dimensions(in.) Weight Max Filter u Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (lbs.) Fuse* Sizes** S9X2130401.12PSAB 2 38,800 25,220 96.000 2,3,4 ® 34 x 17+/2 x 283/4 122 15 16 x 25 x 1 S9X260401-131PSAB 3 38,800 25,220 96.00 2,3,4 ® 34 x 17+/2 x 283/4 122 15 16 x 25 x 1 ❑ S9X2130601-13PSAB 3 58,200 37,830 96.0® 2,3,4 ® 34 x 17+/2 x 283/4 127 15 16 x 25 x 1 o S9X213060U4PSAB 4 58,200 37,830 96.0® 2,3,4 ® 34 x 17+/2 x 283/4 130 15 16 x 25 x 1 Oo' • S9X213080U3PSAB 3 77,600 50,440 96.00 2,3,4 ® 34 x 17+/2 x 283/4 132 15 16 x 25 x 1 S9X260801-141PSAB 4 77,600 50,440 95AD 2,3,4 ® 34 x 17+/2 x 283/4 135 15 16 x 25 x 1 S9X2 S9X21308011.14PSAB 4 77,600 50,440 96.0® 2,3,4 ® 34 x 21 x 283/4 149 15 20 x 25 x 1 Direct Vent S9X2C080U5PSA6 5 77,600 50,440 96.00 2,3,4 ® 34 x 21 x 283/4 149 15 20 x 25 x 1 Upflow S9=10004PSAB 4 97,000 63,050 96.00 2,3,4 ® 34 x 21 x 283/4 154 15 20 x 25 x 1 S9=100051PSAB 5 97,000 63,050 96.00 2,3,4 ® 34 x 21 x 283/4 155 15 20 x 25 x 1 S9X2D120U5PSAB 5 116,400 75,660 95.0® 3,4 ® 34 x 24+/2 x 283/4 167 15 24 x 25 x 1 o e o Table FUR-2-B-S9X2 5 Speed High Efficiency ECM Motor,2 Stage,Direct/Non-Direct Vent,Downflow,Condens- ing Gas Furnace(120/1/60)O Airflow Flue Uncrated Shipping Unit In Output(Btuh) ICSO Size Ignition Dimensions(in.) Weight Max Filter Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (lbs.) Fuse* Sizes** S9X2BO4OD2PSAB 2 38,800 25,220 96.0( 2,3,4 ® 34 x 17+/2 x 283/4 122 15 (2)14 x 20 x 1 El S9X2BO6OD3PSAB 3 58,200 37,830 95.000 2,3,4 ® 34 x 17+/2 x 283/4 127 15 (2)14 x 20 x 1 O' S9X2BO8OD4PSAB 4 77,600 50,440 95.002 2,3,4 ® 34 x 17+/2 x 283/4 135 15 (2)14 x 20 x 1 S9=1005PSAB 5 97,000 63,050 95.002 2,3,4 ® 34 x 21 x 283/4 155 15 (2)16 x 20 x 1 S9X2 S9X2D120D5PSAB 5 116,400 75,660 95.002 3,4 ® 34 x 24+/2 x 283/4 167 15 (2)16 x 20 x 1 Direct Vent Isolated Combustion System. AFUE may vary based on poise. Downflow O Energy Star. O Direct drive 5 speed motor is a high efficiency constant torque ECM blower motor. 0 Silicon Nitride Igniter. * Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. **Filters are not shipped with furnace. For Upflow furnaces,the size is for a bottom return filter. Table FUR-2-C-High Altitude Pressure Switch S9V2-VS 90%Furnaces Model Shipping Number Description Used With Weight BAYHALT250 2 Switches S9V2BO4OU3VSA 2 BAYHALT251 2 Switches S9V2BO6OU3VSA 2 BAYHALT252 2 Switches S9V2BO8OU3VSA,S9V2BO8OD3VSA 2 S9V2C100D4VSA BAYHALT253 2 Switches S9V2C10004VSA 2 BAYHALT254 2 Switches S9V2D12OU5VSA 2 For complete equipment/combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Effective 1/1/19 Guides and Limited Warranty Handbooks. FUR-2 14-1011-36 BUILT TO A HIGHER STANDARD' Amm?w s*Idwd. HEATING & AIR CONDITIONING Convertible Gas Furnaces S9V2-VS S9V2 S9X2 Table FUR-3-A—Features Variable Speed Variable Speed Multi-Speed • Comfort-R"enhanced mode(cooling)............................................................................................................. ✓ ✓ — • Standard 34"height.......................................................................................................................................... ✓ ✓ ✓ • 3 Way poise Upflow furnace model(Upflow,Horzontal Left,Horizontal Right)................................................ ✓ ✓ ✓ • Dedicated Downf low furnace model................................................................................................................. ✓ ✓ ✓ • Front service access with easily accessible burners,sensors,orifices,switches,and other components ..... ✓ ✓ ✓ • Cabinet has no knockouts-Rubber and plastic plugs come installed from factory......................................... ✓ ✓ ✓ • Gas can enter either side of cabinet ................................................................................................................ ✓ ✓ ✓ • Condensate can exit either side of cabinet in Upflow orientation..................................................................... ✓ ✓ ✓ • Multiple venting options-Every model,every size will offer two venting options............................................. ✓ ✓ ✓ • New Integrated Furnace Control board with digital configuration,status,and fault codes............................... ✓ ✓ ✓ • Improved alpha-numeric diagnostic codes....................................................................................................... ✓ ✓ ✓ • Dry contact Humidifier/EAC hook-up capability................................................................................................ ✓ ✓ ✓ • Adjustable blower off delay for heating and cooling.......................................................................................... ✓ ✓ ✓ • Last six fault codes are stored(even with power loss)..................................................................................... ✓ ✓ ✓ • Stainless steel primary and secondary heat exchanger tubes......................................................................... ✓ ✓ ✓ • Longer IFC wire harnesses allow door to be removed without disconnecting the harness............................. ✓ ✓ ✓ • Alternate bottom/left/right return air(upflow models only)........................................................................................ ✓ ✓ ✓ • Bottom panel .................................................................................................................................................. ✓ ✓ ✓ • Direct drive,variable speed ECM blower motor-Constant airflow ECM(electronically commutated motor).. ✓ ✓ — • Direct drive,multi speed ECM blower motor-Constant torque ECM(electronically commutated motor)....... — — ✓ • Dual PVC pipe venting(1 or 2 pipe option)...................................................................................................... ✓ ✓ ✓ • Two stage combination gas valve and regulator............................................................................................... ✓ ✓ ✓ • Gasketed inner and outer door......................................................................................................................... ✓ ✓ ✓ • Variable speed draft inducer motor................................................................................................................... ✓ — — • Heavy gauge reinforced wrap-around steel cabinet.............................................................................................. ✓ ✓ ✓ • Insulated blower compartment.......................................................................................................................... ✓ ✓ ✓ • Left/right condensate drain capability in vertical application............................................................................ ✓ ✓ ✓ • Service diagnostics with faults reported on IFC board..................................................................................... ✓ ✓ ✓ • Manual reset flame roll out switches................................................................................................................. ✓ ✓ ✓ • Mobile home approved with mobile home kit.................................................................................................... ✓ ✓ ✓ • Multi-port in shot burners.................................................................................................................................. ✓ ✓ ✓ • Painted cabinet two tone color.......................................................................................................................... ✓ ✓ ✓ • Service diagnostic capabilities.......................................................................................................................... ✓ ✓ ✓ • Vortica®II blower housing................................................................................................................................ ✓ ✓ ✓ • Slide out blower assembly on full-length rails................................................................................................... ✓ ✓ ✓ • Side return duct starter tabs(upflow models only)............................................................................................ ✓ ✓ ✓ • Silicon Nitride 120V hot surface igniter............................................................................................................ ✓ ✓ ✓ • Multiple heating blower speeds......................................................................................................................... ✓ ✓ ✓ • Meets requirements for 1%or less air leakage................................................................................................ ✓ ✓ ✓ • Registered limited lifetime heat exchanger warranty& 10-year on all other functional parts(Residential Use)0......................................................................... ✓ ✓ ✓ • Optional extended warranties available ...................................................................................................... ✓ ✓ ✓ Note: Variable speed furnaces should not be twinned and are not approved for twinning applications. O Registered Limited Warranty terms are available when you register within 60 days of installation.You can register online at americanstandardair.com or by phone at 800-554-8005;otherwise American Standard Heating&Air Conditioning's Base Limited Warranty terms will apply.Base Limited Warranty information on specific prod- ucts can be found on ASDealerNet.com. S9V2-VS 2 Stage S9V2-2 Stage S9X2-2 Stage Table FUR-3-B—Optional Accessories 1 or 2 Pipe 1 or 2 Pipe 1 or 2 Pipe Model Number Description Shipping Weight BAYLPSS400B..........LP Kit with Stainless Steel Burners........................................................................3 ....... ✓ ✓ ✓ BAYHANG .................Horizontal hanging kit.............................................................................................2 ....... ✓ ✓ ✓ BAYVENT200B..........Sidewall vent Termination Kit fo Direct vent furnaces.............................................2 ....... ✓ ✓ ✓ BAYVENTCN200B.....Sidewall vent Termination Kit fo Direct vent furnaces for Canadian applications...2 ....... ✓ ✓ ✓ BAYAIR30AVENTA.....Concentric vent kit for 2,21/2 and 3"vent system .................................................11 ....... ✓ ✓ ✓ BAYAIR30CNVENT....Concentric vent kit for 2,21/2 and 3"vent system for Canadian applications .......11 ....... ✓ ✓ ✓ BAYREDUCE.............Reducer Coupling for Canadian applications(CPVC)............................................1 ....... ✓ ✓ ✓ BAYLIFTB...................Dual return kit. B size extension.............................................................................8 ....... ✓ ✓ ✓ BAYLIFTC...................Dual return kit. C size extension............................................................................9 ....... ✓ ✓ ✓ BAYLIFTD...................Dual return kit. D size extension............................................................................9 ....... ✓ ✓ ✓ BAYMFGH2O0B.........Manufactured/mobile home kit...............................................................................1 ....... ✓ ✓ ✓ BAYCNDTRAP2A.......In-line condensate collector for 2"PVC pipe .........................................................1 ....... ✓ ✓ ✓ BAYCNDTRAP3A.......In-line condensate collector for 3"PVC pipe .........................................................1 ....... ✓ ✓ ✓ BAYBASE205.............Downflow subbase..................................................................................................8 ....... ✓ ✓ ✓ BAYFLTR206..............Filter Access Door Kit(Downflow only)...................................................................2 ....... ✓ ✓ ✓ For complete equipment/combination selections, installation instructions and warranty information, Effective 1/1/19 please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-3 14-1011-36 BUILT TO A HIGHER STANDARD' Platinum 95, Silver 95h, Silver 95, and ,4A&e,6q S�tgd&r /® American Standard 92 Convertible Gas HEATING & AIR CONDITIONING Furnaces Airflow Directions IN 0 0 DOWNFLOW AIR Qp AIR FLOW FLOW UPFLOW ' 0 AIR AIR FLOW UPFLOW/HORIZONTAL DOWNFLOW/HORIZONTAL FLOW 0 �—_3 0 AIR AIR 1J FLOW UPFLOW/HORIZONTAL DOWNFLOW/HORIZONTAL FLOW 000000 o 0 00000 Note:The forty inch (40") height condensing downflow/horizontal and upflow/horizontal furnaces may only be rotated onto their left side.Connection brackets for coil/furnace alignment are included with the furnaces.The apex of the coil may point into or away from the airflow. For complete equipment/combination selections, installation instructions and warranty information, Effective 1/1/19 please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-4 14-1011-36 BUILT TO A HIGHER STANDARD'" ,4&p,�ay S q,*rd. Platinum 95 - Modulating, HEATING & AIR CONDITIONING Communicating ECM Variable Speed Table FUR-5-A—Platinum 95 Variable Speed,Communicating,Modulating Direct/Non-Direct Vent,Upflow/ Horizontal Left Condensing Gas Furnace(115/1/60)000 Airflow Output(Btuh) ICSO Uncrated Shipping Unit In High Stage Low Stage AFUE Flue Size Dimensions(in.) Weight Max Filter Model No. Tons 100% 40%® Upflow/Horiz (in) H x W x D (lbs.) Fuse* Sizes** AUHMB060ACV3VB 3 57,000 23,000 97.30/96.50 2,21/2,3 40 x 171/2 x 28 158 15 17 x 25 x 1 AUHMB080ACV3VB 3 76,000 31,000 97.O0/96.20 2,21/2,3 40 x 171/2 x 28 168 15 17 x 25 x 1 AUHMC100ACV4VB 4 95,000 39,000 96.00/95.20 21/2,3 40 x 21 x 28 197 15 20 x 25 x 1 AUHMD120ACV5VB 5 114,000 52,000 97.O00 /96.2® 3 40 x 241/2 x 28 206 15 24 x 25 x 1 Platinum 95 Direct/Non-Direct Vent Upflow Table FUR-S-B—Platinum 95 Variable Speed,Communicating Modulating Direct/Non-Direct Vent, Downflow/Horizontal Right Condensing Gas Furnace(115/1/60)000 Airflow Output(Btuh) Flue Uncrated Shipping Unit In High Stage Low Stage ICSO Size Ignition Dimensions(in.) Weight Max Filter Model No. Tons 100% 40% AFUE (in) Device H x W x D (lbs.) Fuse* Sizes ADHMB060BCV3VB 3 57,000 22,800 95.00 2,21/2,3 © 40 x 171/2 x 28 160 15 (2)14 x 20 x 1 ADHMB080ACV3VB 3 76,000 30,400 96.00 2,21b,3 © 40 x 171b x 28 168 15 (2)14 x 20 x 1 ADHMC100ACV4VB 4 96,000 38,400 96.00 21/2,3 © 40 x 21 x 28 185 15 (2)16 x 20 x 1 ADHMD120BCV5VB 5 114,000 51,300 95.002 3 © 40 x 241/2 x 28 206 15 (2)16 x 20 x 1 Note:Variable speed furnaces should not be twinned and are not approved for twinning applications 0 Isolated Combustion System. AFUE may vary based on poise. Platinum 95 ®Energy Star. Direct/Non-Direct O Low stage is equal to 45%for AUHMD120 model. Vent Downflow ®Furnace use in 24,non-communicating mode. ©Direct drive variable speed motor is an ECM constant airflow blower motor. O Silicon Nitride 0 Must use communicating thermostat with AccuLinkTM II control. * Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. For Upflow furnaces,the size is for a bottom return filter. Silver 95h - Single Stage with ECM Multi-Speed Motor Table FUR-S-C—Silver 95h Direct/Non-Direct Vent,Upflow/Horizontal Left Condensing Gas Furnace with Filter Airflow Nominal ICSO Flue Uncrated Shipping Unit In Output AFUE Size Ignition Dimensions(in.) Weight Max Filter Model No. Tons (Btuh) Upflow/Horiz (in) Device H x W x D (lbs.) Fuse* Sizes** AUH1 B040A9H21 B 2 38,000 95.0/94.2 2,2'/2,3 O 40 x 171/2 x 28 139 15 17 x 25 x 1 AUH1 B060A9H31 B 3 57,000 95.00/94.2 2,2'/2,3 O 40 x 171/2 x 28 150 15 17 x 25 x 1 AUH1 B080A9H31 C 3 73,150 95.0®/94.2 2,2'/2,3 O 40 x 171/2 x 28 158 15 17 x 25 x 1 AUH1 C100A9H41 B 31/2 92,150 95.00/94.2 3 O 40 x 21 x 28 171 15 20 x 25 x 1 Silver 95h Direct/Non-DirectUpflow VetTable FUR-S-D—Silver 95h Direct/Non-Direct Vent,Downflow/Horizontal Right Condensing Gas Furnace with Filter Vent Up Airflow Nominal Flue Uncrated Shipping Unit In Output ICSO Size Ignition Dimensions(in.) Weight Max Filter Model No. Tons (Btuh) AFUE (in) Device H x W x D (lbs.) Fuse* Sizes** ADH 1 B040A9H21 B 2 38,000 95.0 2,21/2,3 O 40 x 171/2 x 28 145 15 (2)14 x 20 x 1 ADH 1 B065A9H31 B 3 57,000 95.00 2,2'/2,3 ® 40 x 171/2 x 28 158 15 (2)14 x 20 x 1 ADH 1 C085A9H41 B 4 76,000 95.00 21/2,3 O 40 x 21 x 28 171 15 (2)16 x 20 x 1 ADH1 D110A9H51 B 5 104,500 95.00 21/2,3 O 40 x 241/2 x 28 205 15 (2)16 x 20 x 1 O Isolated Combustion System. AFUE may vary based on poise. ®Silicon Nitride Igniter.. ®Energy Star Silver 95h * Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. Direct/Non-Direct **For Upflow furnaces,the size is for a bottom return filter. Vent Downflow For complete equipment/combination selections, installation instructions and warranty information, Effective 1/1/19 please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-5 14-1011-36 BUILT TO A HIGHER STANDARD" Amw " S7�tffdard® HEATING & AIR CONDITIONING Silver 95 - Single Stage Table FUR-6-A—Silver 95 Direct/Non-Direct Vent,Upflow/Horizontal Left Condensing Gas Furnace(115/1/60) Airflow Nominal ICSO Flue Uncrated Shipping Unit In Output AFUE Size Ignition Dimensions(in.) Weight Max Filter** Model No. Tons (Btuh) Upflow/Horiz (in) Device H x W x D (lbs.) Fuse* Sizes AU 1 B040A9241 C 2 38,000 95.0/94.2 2,2'/2,3 O 40 x 171/2 x 28 139 15 17 x 25 x 1 AUH1 B060A9361 C 3 57,000 95.0/94.2 2,2'/2,3 O 40 x 171/2 x 28 150 15 17 x 25 x 1 AUH1 B080A9421 C 31/2 73,150 95.0/94.2 2,2'/2,3 ® 40 x 171/2 x 28 158 15 17 x 25 x 1 AUH1 C080A9601 C 5 76,000 95.0/94.2 3 ® 40 x 21 x 28 171 20 20 x 25 x 1 Silver 95 AUH1 Cl OOA9481 C 4 92,150 95.0/94.2 3 ® 40 x 21 x 28 171 20 20 x 25 x 1 Direct/Non-Direct AUH1 Dl OOA9601 C 5 92,150 95.0/94.2 3 ® 40 x 241/2 x 28 197 20 24 x 25 x 1 Vent Upflow AUH1 D120A9601 C 5 104,500 95.0/94.2 3 ® 40 x 241/2 x 28 205 20 24 x 25 x 1 Table FUR-6-B—Silver 95 Direct/Non-Direct Vent,Downflow/Horizontal Right Condensing Gas Furnace(115/1/60) Airflow Nominal Flue Uncrated Shipping Unit In Output ICSO Size Ignition Dimensions(in.) Weight Max® Filter** Model No. Tons (Btuh) AFUE (in) Device H x W x D (lbs.) Fuse* Sizes in M ADH1604OA9241 C 2 38,000 95.0 2,21/2,3 ® 40 x 17112 x 28 155 15 (2)14 x 20 x 1 iffADH16065A9421 C 31/2 57,000 95.0 2,21/2,3 ® 40 x 171/2 x 28 168 15 (2)14 x 20 x 1 ADH1 C085A9481 C 4 76,000 95.0 21/2,3 ® 40 x 21 x 28 185 20 (2)16 x 20 x 1 ADH1 D110A9601 C 5 104,500 95.0 21/2,3 O 40 x 241/2 x 28 206 20 (2)16 x 20 x 1 O Isolated Combustion System. AFUE may vary based on poise. Silver 95 ®Silicon Nitride Igniter. Direct/Non-Direct* Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. Vent Downflow **Filters are not shipped with furnace. For Upflow furnaces,the size is for a bottom return filter. American Standard 92 - Single Stage Table FUR-6-C—AS92 Direct/Non-Direct Vent,Upflow/Horizontal Left Condensing Gas Furnace(115/1/60) Airflow Nominal ICSOO Flue Uncrated Shipping Unit In Output AFUE Size Ignition Dimensions(in.) Weight Max Filter** o Model No. Tons (Btuh) Upflow/Horiz (in) Device H x W x D (lbs.) Fuse* Sizes AUC1 B040A9241 A 2 37,000 92.1 /91.3 2,2'/2,3 Silicon Nitride 40 x 171/2 x 28 139 15 17 x 25 x 1 AUC1 B060A9361A 3 56,000 92.1/91.3 2,2'/2,3 Silicon Nitride 40 x 171/2 x 28 150 15 17 x 25 x 1 ° AUC1 B080A9421 A 31/2 74,000 92.1/91.3 2,2'/2,3 Silicon Nitride 40 x 171/2 x 28 158 15 17 x 25 x 1 AUCl Cl OOA9481 A 4 94,000 92.1/91.3 21/2,3 Silicon Nitride 40 x 21 x 28 171 20 20 x 25 x 1 AUCl Dl OOA9601 A 5 93,000 92.1/91.3 21/2,3 Silicon Nitride 40 x 241/2 x 28 197 20 24 x 25 x 1 American AUC1 D120A9601 A 5 113,000 92.1 /91.3 21/2,3 Silicon Nitride 40 x 241/2 x 28 205 20 24 x 25 x 1 Standard 92 Upflow Table FUR-6-D—AS92 Direct/Non-Direct Vent,Downflow/Horizontal Right Condensing Gas Furnace(115/1/60) Airflow Nominal Flue Uncrated Shipping Unit In Output ICSO Size Ignition Dimensions(in.) Weight Max Filter** ° Model No. Tons (Btuh) AFUE (in) Device H x W x D (lbs.) Fuse* Sizes ADC16040A9241A 2 37,000 92.1 2,2'/2,3 Silicon Nitride 40 x 171/2 x 28 145 15 (2)14 x 20 x 1 ADC1 B060A9361 A 3 56,000 92.1 2,2'/2,3 Silicon Nitride 40 x 171/2 x 28 155 15 (2)14 x 20 x 1 == ADC1 B080A9421 A 31/2 74,000 92.1 2,2'/2,3 Silicon Nitride 40 x 171/2 x 28 168 15 (2)14 x 20 x 1 _ ADCl Cl OOA9481 A 4 93,000 92.1 21/2,3 Silicon Nitride 40 x 21 x 28 185 20 (2)16 x 20 x 1 ADC1 D120A9601 A 5 112,000 92.1 21/2,3 Silicon Nitride 40 x 241/2 x 28 206 20 (2)16 x 20 x 1 American D Isolated Combustion System. AFUE may vary based on poise. Standard 92 * Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. Downflow *'Filters are not shipped with furnace. For Upflow furnaces,the size is for a bottom return filter. For complete equipment/combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Effective 1/1/19 Guides and Limited Warranty Handbooks. FUR-6 14-1011-36 BUILT TO A HIGHER STANDARD'" Platinum 95, Silver 95, Silver 95h, and 4`*M?jq S7�;qd�® American Standard 92 Convertible Gas HEATING & AIR CONDITIONING Furnaces Airflow Directions: AUHM AUH1-H AUH1 AUC1 Downflow models when placed in horizontal position provide ADHM ADH1-H ADH1 ADCs left to right airflow.Upflow models when placed in horizontal Modulating 1 Stage 1 Stage 1 Stage position provide right to left airflow. 1 or 2 Pipe 1 or 2 Pipe 1 or 2 Pipe 1 or 2 Pipe Table FUR-7-A—Features Variable Speed • Comfort-F!"enhanced mode(cooling)................................................................................... ✓ — — — • AccuLinkTM II system®.......................................................................................................... ✓ — — — • Meets requirements for 2%or less air leakage........................................................................... ✓ ✓ ✓ — • Adjustable heating fan off timing............................................................................................. ✓ ✓ ✓ ✓ • Alternate bottom/left/right return air(upflow models only)............................................................... ✓ ✓ ✓ ✓ • Blower door safety switch........................................................................................................ ✓ ✓ ✓ ✓ • Bottom panel(upflow models only).......................................................................................... ✓ ✓ ✓ ✓ • Cleanable/Reusable high velocity filters................................................................................. ✓ ✓ — — • Complete front service access................................................................................................ ✓ ✓ ✓ ✓ • Direct drive,multi-speed(PSC)blower motor......................................................................... — — ✓ ✓ • Direct drive,multi-speed ECM blower motor(high efficiency)'................................................. — ✓ — — • Direct drive,variable speed ECM blower motor"................................................................... ✓ — — — • Downflow horizontal right(downflow models only)..................................................................... ✓ ✓ ✓ ✓ • Dual PVC pipe venting(1 or 2 pipe option)............................................................................. ✓ ✓ ✓ ✓ • Two stage combination gas valve and regulator..................................................................... — — — — • One stage combination gas valve and regulator..................................................................... — ✓ ✓ ✓ • Modulating gas valve and regulator........................................................................................ ✓ — — — • Gasketed blower door(upflow models only)............................................................................ ✓ ✓ ✓ — • Heavy gauge reinforced wrap-around steel cabinet..................................................................... ✓ ✓ ✓ ✓ • Humidifier/EAC hook-up capability......................................................................................... ✓ ✓ ✓ — • Inner blower door panel(downflow models only).................................................................... ✓ ✓ ✓ ✓ • Insulated blower compartment 4 sides................................................................................... ✓ ✓ ✓ — • Integrated solid state control w/self diagnostics...................................................................... ✓ — — — • Left/right condensate drain capability in vertical application................................................... ✓ ✓ ✓ ✓ • Service diagnostics with faults reported at the user interface................................................. ✓ — — — • Lite Port'"/Stored diagnostics.................................................................................................. ✓ — — — • Manual reset flame roll out switches....................................................................................... ✓ ✓ ✓ ✓ • Mobile home approved w/BAYMFGH100A............................................................................. — ✓ ✓ ✓ • Multi-port in shot burners........................................................................................................ ✓ ✓ ✓ ✓ • Painted cabinet single color.................................................................................................... — — — ✓ • Painted cabinet two tone color................................................................................................ ✓ ✓ ✓ — • Service diagnostic capabilities................................................................................................ ✓ ✓ ✓ ✓ • Side return duct starter tabs(upflow models only)................................................................... ✓ ✓ ✓ ✓ • Silicon Nitride hot surface igniter............................................................................................ ✓ ✓ ✓ ✓ • Single wire twinning................................................................................................................ — ✓ ✓ — • Slide out blower assembly....................................................................................................... ✓ ✓ ✓ ✓ • Solid burner door(quiet operation)......................................................................................... ✓ ✓ ✓ — • 20 gauge aluminized steel heat exchanger............................................................................ ✓ ✓ ✓ ✓ • 24 volt secondary fuse............................................................................................................ ✓ ✓ ✓ ✓ • Multiple heating blower speeds............................................................................................... ✓ ✓ — — • Type 29-4C' stainless steel secondary heat exchanger....................................................... ✓ ✓ ✓ ✓ • Upflow horizontal left(upflow models only)............................................................................. ✓ ✓ ✓ ✓ • Variable speed venter motor................................................................................................... ✓ — — — • Registered limited lifetime heat exchanger warranty& 10-year on all other functional parts(Residential Use)O............................................... ✓ ✓ ✓ ✓ • Optional extended warranties available ............................................................................ ✓ ✓ ✓ ✓ Note: Variable speed furnaces should not be twinned and are not approved for twinning applications. O Registered Limited Warranty terms are available when you register within 60 days of installation.You can register online at americanstandardair.com or by phone at 800-554-8005;otherwise American Standard Heating&Air Conditioning's Base Limited Warranty terms will apply.Base Limited Warranty information on specific prod- ucts can be found on ASDealerNet.com. ®Field configurable to 24V non-communicating mode. `Constant torque ECM(electronically commutated motor). —Constant airflow ECM(electronically commutated motor). For complete equipment/combination selections, installation instructions and warranty information, Effective 1/1/19 please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-7 14-1011-36 BUILT TO A HIGHER STANDARD" platinum 95, Silver 95, Silver 95h, and AAPr ?Ao S7�wdmd, American Standard 92 Convertible Gas HEATING & AIR CONDITIONING Furnace Airflow Directions: Downflow models when placed in horizontal position provide left to right airflow.Upflow models when placed in horizontal AUHM/ADHM position provide right to left airflow. Modulating 1 or 2 Pipe Table FUR-8-A—Optional Accessories Variable Speed Model Number Description Shipping Weight BAYBASE205..............Downflow subbase for downflow models only..............................8.................................................................. ✓ BAYFLTR200...............External side filter rack.................................................................5.................................................................. ✓ BAYFLTR203...............Filter kit horiz conversion for 17.5"cabinet..................................3.................................................................. ✓ BAYFLTR204...............Filter kit horiz conversion for 21" cabinet....................................3.................................................................. ✓ BAYFLTR205...............Filter kit horiz conversion for 24.5"cabinet .................................3.................................................................. ✓ BAYFLTR3170 ..........Cleanable filter for 17.5"cabinet upflow only..............................2.................................................................. ✓ BAYFLTR3210 ..........Cleanable filter for 21"cabinet upflow only ................................2.................................................................. ✓ BAYFLTR3240 ..........Cleanable filter for 24.5"cabinet upflow only..............................2.................................................................. ✓ BAYLPKT220B............Propane conversion kit ..................................................................2.................................................................. ✓ BAYLPSS220C............LP Kit with Stainless Steel Burners.............................................2.................................................................. ✓ BAYRACK960A®........Filter rack kit for upflow models only(internal)O.........................5.................................................................. ✓ BAYAIR30AVENTA......Concentric vent kit for 2,21/2 and 3"ven system ........................11................................................................. ✓ BAYVENT200B...........Sidewall vent Termination Kit fo Direct vent furnaces..................2.................................................................. ✓ BAYVENT500A...........Side vent kit for downflow models only........................................3.................................................................. ✓ BAYACCECOMM101 ..AccuCleanTm hookup kit for communicating furnaces.................1.................................................................. ✓ Note:Variable speed furnaces should not be twinned and are not approved for twinning applications. 0 Contains one(1)high velocity filter. OO Internal filter rack for side or bottom return air.Includes 17 x 25"cleanable filter for use in side return applications.Bottom return applications require different sizes of filters which are not included.Airflow requirements over 1800 CFM require filters on both sides or a side and bottom or bottom only. O BAYRACK960A not allowed on right side return on AUH2B080A9V4V"models. Airflow Directions: Downflow models when placed in horizontal position provide left to right airflow.Upflow models when placed in horizontal AUH1-H/ AUH1/ADH1/ AUC1/ADC1 position provide right to left airflow. ADH1-1-1 AUX1/ADX1 1 Stage 2 Stage 1 Stage 1 or 2 Pipe Table FUR-8-113—Optional Accessories 1 or 2 Pipe 1 or 2 Pipe Model Number Description Shipping Weight BAYBASE205...........Downflow subbase for downflow models only...................8.......................................... ✓ ✓ ✓ BAYFLTR200............External side filter rack......................................................5.......................................... ✓ ✓ ✓ BAYFLTR203............Filter kit horiz conversion for 17.5"cabinet.......................3.......................................... ✓ ✓ ✓ BAYFLTR204............Filter kit horiz conversion for 21" cabinet.........................3.......................................... ✓ ✓ ✓ BAYFLTR205............Filter kit horiz conversion for 24.5"cabinet ......................3.......................................... ✓ ✓ ✓ BAYFLTR206............Filter access door kit(Downflow only)...............................2.......................................... ✓ ✓ ✓ BAYFLTR3170 .......Cleanable filter for 17.5"cabinet upflow only...................2.......................................... ✓ ✓ ✓ BAYFLTR3210 .......Cleanable filter for 21"cabinet upflow only .....................2.......................................... ✓ ✓ ✓ BAYFLTR3240 .......Cleanable filter for 24.5"cabinet upflow only...................2.......................................... ✓ ✓ ✓ BAYLPKT210B.........Propane conversion kit .......................................................1 .......................................... ✓ ✓ ✓ BAYLPSS210B ........LP Kit with Stainless Steel Burners...................................1 .......................................... ✓ ✓ ✓ BAYMFGH100A.......Manufactured/mobil home kit ...........................................2.......................................... ✓ ✓ ✓ BAYRACK960A........Filter rack kit for upflow models only(internal)®..............5.......................................... ✓ ✓ ✓ BAYAIR30AVENTA...Concentric vent kit for 2,2'/2 and 3"vent system ............11 ......................................... ✓ ✓ ✓ BAYVENT200B........Sidewall vent Termination Kit fo Direct vent furnaces.......2.......................................... ✓ ✓ ✓ BAYVENT500A........Side vent kit for downflow models only.............................3.......................................... ✓ ✓ ✓ Note:Variable speed furnaces should not be twinned and are not approved for twinning applications. O Contains one(1)high velocity filter. ®Internal filter rack for side or bottom return air.Includes 17 x 25"cleanable filter for use in side return applications.Bottom return applications require different sizes of filters which are not included.Airflow requirements over 1800 CFM require filters on both sides or a side and bottom or bottom only. For complete equipment/combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Effective 1/1/19 Guides and Limited Warranty Handbooks. FUR-8 14-1011-36 BUILT TO A HIGHER STANDARD' Amm?w s*Idwd. HEATING & AIR CONDITIONING Special Use Furnace Accessories Table FUR-9-A—High Altitude Pressure Switch 90% Model Shipping Number Description Used With Weight BAYHALT225 1 Switch AUC080,100C948,120C,ADC080,120C 2 BAYHALT226 1 Switch AUC,ADC060C 2 BAYHALT227 1 Switch AUC10OC948 2 BAYHALT228 1 Switch AUC/ADC040C 2 BAYHALT230 1 Switch AUX/ADX040C,AUX1 B040,D100/ADX1 B040 2 BAYHALT231 1 Switch AUX060C,AUX1060C 2 BAYHALT232 1 Switch AUX080C,AUX1 B080C 2 BAYHALT233 1 Switch AUX100,120C/ADX080,120C,AUXlC100,D12O/ADXlBO80,D12O 2 BAYHALT234 1 Switch ADX100C,ADX1C100 2 BAYHALT241 1 Switch ADX060C,ADX1 B060 2 BAYHALT245 2 Switches ADX/AUX/ADY/AUY060-R 2 BAYHALT246 2 Switches ADX/AUX/ADY/AUY080,100-R 2 BAYHALT247 2 Switches ADX/AUX/ADY/AUY120-R 2 BAYHALT248 1 Switch AUD1/ADDI,AUE1/ADE 2 BAYHALT249 1 Switch AUD2,AUD-R-K,ADD-R-F,ADD2 2 Table FUR-9-13—High Altitude Pressure Switch 90% Model Shipping Number Description Used With Weight BAYSWT01AHALTA 1 Switch AUC1 B040,AUC1 D100,ADC1 B040,AUX1 B040, 2 AUX1 D100,ADX1 B040,AUH1 B040,ADH1 B040,ADH1 C085 2 BAYSWT02AHALTA 1 Switch AUC1 B060,AUX1 B060 2 BAYSWT03AHALTA 1 Switch AUC11 B080,AUX1 B080 2 BAYSWT04AHALTA 1 Switch AUC1C100,AUC1D120,ADC1B080, 2 ADC1 C100,ADC1 D120,AUX1 C100,AUX1 D120, ADX1 B080,ADX1 D120,AU H 1 B060,AUH 1 D 100,AUH 1 D120 BAYSWT05AHALTA 1 Switch ADX1C100,AUH1B080,AUH1C100,ADH1D110 2 BAYSWT06AHALTA 1 Switch ADCs B060,ADX1 B060 2 BAYSWT07AHALTA 1 Switch AUH3/AUHMB060,ADH3/ADHMB060,AUX2B060,ADX2B060, 2 AUY060R,ADY060R BAYSWT08AHALTA 1 Switch AUX2B080,AUX2C100,ADX2B080,ADX2C100,AUY120R,ADY120R, 2 AUH2B080,ADH2B080,AUH2C100,ADH2C100,AUH2D120, ADH2D120,AUH3/AUHMD120,ADH3/ADHMD120 BAYSWT09AHALTA 1 Switch AUX2D120,ADX2D120,AUY080R,ADY080R,AUY100R, 2 ADY 100 R,AU H 3/AU H M B 080,A D H 3/A D H M B 080,AUH 3/AU H M C 100, ADH/ADHM3C100 BAYSWT10AHALTA 1 Switch AUH2B060A,ADH2B060A 2 BAYSWTIIAHALTA 1 Switch ALIH1C080 2 BAYSWTI2AHALTA 1 Switch ADH1 B065 2 BAYSWT01AMALTB 1 Switch AUXII 2 The following changes occurred beginning with serial number 6151: 1. All 2 stage furnace changed from two separate pressure switches to one piggy back switch. 2. The high altitude pressure switches are now piggy back. 3. The new piggy back switches are not interchangeable with the original two switch design. 4. The pressure switch mounting plate is different for the piggy back switches. Table FUR-9-C—Dual Fuel Heat Pump Control Kite Model Number Case Height Used With TAYPLUS103A.............Heat Pump Control Kit............Gas,LP.,Oil and Electric Furnaces TAYSTAT250B..............Outdoor Thermostat................TAYPLUS103A for Restricted Mode O Factory wired for non-restricted mode,can be wired for restricted mode. O Applicable for all furnaces with 35 VA or larger low voltage transformer(separate high voltage power not required). Bonnet TAYPLUS103A Switch For complete equipment/combination selections, installation instructions and warranty information, Effective 1/1/19 please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-9 14-1011-36 BUILT TO A HIGHER STANDARD" Amer lw S7�tffdmd® HEATING & AIR CONDITIONING S8X2 - Two Stage ECM Table FUR-10-A-S8X2 2 Stage,Upflow/Downflow/Horizontal Left/Horizontal Right,Non-Condensing,Induced Draft Gas Furnace(120/1/60)O Airflow Flue Uncrated Shipping Unit In Output(Btuh) ICSO Size Ignition Dimensions(in.) Weight Max Filter ®. Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (lbs.) Fuse* Sizes** 0o S8X2AO4OM3PSAA 2-3 32,000 20.800 80.0 4 O 34 x 141/2 x 283/4 102 15 14 x 25 x 1 S8X2BO6OM3PSAA 3 48,000 31,200 80.0 4 O 34 x 171/2 x 283/4 130 15 16 x 25 x 1 S8X2BO6OM4PSAA 4 48,000 31,200 80.0 4 O 34 x 171/2 x 283/4 132 15 16 x 25 x 1 l� S8X26080M4PSAA 3-4 64,000 41,600 80.0 4 O 34 x 171/2 x 283/4 137 15 16 x 25 x 1 S8X2CO8OM5PSAA 4-5 64,000 41,600 80.0 4 O 34 x 21 x 283/4 142 15 20 x 25 x 1 S8X2C100M5PSAA 4-5 80,000 52,000 80.0 4 O 34 x 21 x 283/4 144 15 20 x 25 x 1 S8X2 S8X2D120M5PSAA 5 96,000 67,200 80.0 4 O 34 x 241/2 x 283/4 160 15 24 x 25 x 1 4-Way Low NOx Models Multi-Poise S8X2AO4OM3PTAA 2-3 32,000 20.800 80.0 4 ® 34 x 141/2 x 283/4 102 15 14 x 25 x 1 S8X2BO6OM3PTAA 3 48,000 31,200 80.0 4 O 34 x 171/2 x 283/4 130 15 16 x 25 x 1 S8X26060M4PTAA 4 48,000 31,200 80.0 4 O 34 x 171/2 x 283/4 132 15 16 x 25 x 1 S8X2B080M4PTAA 3-4 64,000 41,600 80.0 4 O 34 x 171/2 x 283/4 137 15 16 x 25 x 1 S8X2CO8OM5PTAA 4-5 64,000 41,600 80.0 4 O 34 x 21 x 283/4 142 15 20 x 25 x 1 S8X2C100M5PTAA 4-5 80,000 52,000 80.0 4 O 34 x 21 x 283/4 144 15 20 x 25 x 1 S8X2D120M5PTAA 5 96,000 67,200 80.0 4 O 34 x 241/2 x 283/4 160 15 24 x 25 x 1 O Isolated Combustion System. ®9 Speed direct drive motor is an ECM constant torque motor. O Silicon Nitride Igniter. ®These models comply with California 40ng/J Low NOx regulations. * Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. **Filters are not shipped with furnace. S8X1 - Single Stage ECM Table FURA0-B-S8X1 1 Stage,Upflow/Downflow/Horizontal Left/Horizontal Right,Non-Condensing,Induced Draft Gas Furnace(120/1/60)9 Airflow Nominal Flue Uncrated Shipping Unit In Output ICSO Size Ignition Dimensions(in.) Weight Max Filter Model No. Tons (Btuh) AFUE (in) Device H x W x D (lbs.) Fuse* Sizes** OD S8X1 A026M2PSAA 2 20,800 80.0 4 3 34 x 141/2 x 283/4 102 15 14 x 25 x 1 S8X1 A040M3PSAA 2-3 32,000 80.0 4 O 34 x 141/2 x 283/4 102 15 14 x 25 x 1 ° S8X1 B040M2PSAA 2 32,000 80.0 4 O 34 x 171/2 x 283/4 128 15 16 x 25 x 1 S8X1 B060M3PSAA 3 48,000 80.0 4 O 34 x 171/2 x 283/4 130 15 16 x 25 x 1 S8X1 13060M4PSAA 4 48,000 80.0 4 O 34 x 171/2 x 283/4 132 15 16 x 25 x 1 S8X1 B080M4PSAA 3-4 64,000 80.0 4 O 34 x 171/2 x 283/4 137 15 16 x 25 x 1 S8X1 S8X1 C080M5PSAA 4-5 64,000 80.0 4 O 34 x 21 x 283/4 142 15 20 x 25 x 1 4-Way S8X1 C100M5PSAA 4-5 80,000 80.0 4 O 34 x 21 x 283/4 144 15 20 x 25 x 1 Multi-Poise S8X1 D120M5PSAA 5 96,000 80.0 4 ® 34 x 241/2 x 283/4 160 15 24 x 25 x 1 Low NOx Models O S8X1 A026M2PTAA 2 20,800 80.0 4 3 34 x 141/2 x 283/4 102 15 14 x 25 x 1 S8X1 A040M3PTAA 2-3 32,000 80.0 4 O 34 x 141/2 x 283/4 102 15 14 x 25 x 1 S8X16040M2PTAA 2 32,000 80.0 4 O 34 x 171/2 x 283/4 128 15 16 x 25 x 1 S8X1 B060M3PTAA 3 48,000 80.0 4 O 34 x 171/2 x 283/4 130 15 16 x 25 x 1 S8X1 B060M4PTAA 4 48,000 80.0 4 O 34 x 171/2 x 283/4 132 15 16 x 25 x 1 S8X16080M4PTAA 3-4 64,000 80.0 4 O 34 x 171/2 x 283/4 137 15 16 x 25 x 1 S8X1 C080M5PTAA 4-5 64,000 80.0 4 O 34 x 21 x 283/4 142 15 20 x 25 x 1 S8X1 C100M5PTAA 4-5 80,000 80.0 4 O 34 x 21 x 283/4 144 15 20 x 25 x 1 S8X1 D120M5PTAA 5 96,000 80.0 4 O 34 x 241/2 x 283/4 160 15 24 x 25 x 1 O Isolated Combustion System. ®9 Speed direct drive motor is an ECM constant torque motor. O Silicon Nitride Igniter. ®These models comply with California 40ng/J Low NOx regulations. * Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. **Filters are not shipped with furnace. For complete equipment/combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Effective 1/1/19 Guides and Limited Warranty Handbooks. FUR-10 14-1011-36 BUILT TO A HIGHER STANDARD' Amm?w s*Idwd. HEATING & AIR CONDITIONING Convertible Gas Furnaces Table FUR-11-A—High Altitude Pressure Switch S8 Furnaces Model Shipping Number Description Used With Weight BAYSWTI3AHALTA 1 Switch S8X1A026M2PSAA 2 BAYSWTI4AHALTA 1 Switch S8X1A040M3PSAA,S8X113040M2PSAA 2 S8X1C080M5PSAA,S8X1C100M5PSAA BAYSWTI5AHALTA 1 Switch S8X1 B060M3PSAA,S8X1 13060M4PSAA 2 S8X1B080M4PSAA BAYSWTI6AHALTA 2 Switches S8X2A040M3PSAA,S8X2C080M5PSAA 2 BAYSWTI7AHALTA 2 Switches S8X2130601V13PSAA,S8X2130601V14PSAA 2 BAYSWTI8AHALTA 2 Switches S8X2130801V14PSAA 2 BAYSWTI9AHALTA 2 Switches S8X2C1001V15PSAA 2 Note: S8X1 D120M5 and S8X2D120M5 do not require high altitude pressure switch kits. Note: S8X1A0261VI2,S8X1A040M3,S8X1 B040M2,and S8X2A040M3 require new orifices included in kit. For complete equipment/combination selections, installation instructions and warranty information, Effective 1/1/19 please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-11 14-1011-36 BUILT TO A HIGHER STANDARD" Amw " S7�tffdmd® HEATING & AIR CONDITIONING Convertible Gas Furnaces S8X1 S8X2 Table FUR-12-A—Features 1 Stage 2 Stage • Standard 34"height.......................................................................................................................................... ✓ ✓ • 4 Way poise(Upflow,Downf low,Horizontal Left,Horizontal Right).................................................................. ✓ ✓ • Front service access with easily accessible burners,sensors,orifices,switches,and other components ..... ✓ ✓ • Cabinet has no knockouts-Plastic plugs come installed from factory............................................................. ✓ ✓ • Gas can enter either side of cabinet................................................................................................................ ✓ ✓ • Multiple venting options-Every model,every size offers two venting options................................................. ✓ ✓ • New Integrated Furnace Control board with digital configuration,status,and fault codes............................... ✓ ✓ • Improved alpha-numeric diagnostic codes....................................................................................................... ✓ ✓ • Dry contact Humidifier/EAC hook-up capability................................................................................................ ✓ ✓ • Adjustable blower off delay for heating and cooling.......................................................................................... ✓ ✓ • Last six fault codes are stored(even with power loss)..................................................................................... ✓ ✓ • Aluminized heat exchanger tubes..................................................................................................................... ✓ ✓ • Longer IFC wire harnesses allow door to be removed without disconnecting the harness............................. ✓ ✓ • Alternate bottom/left/right return air(except downflow)............................................................................................ ✓ ✓ • Bottom panel ................................................................................................................................................ ✓ ✓ • Direct drive,9 speed Constant Torque ECM blower motor.............................................................................. ✓ ✓ • Two stage combination gas valve and regulator............................................................................................... — ✓ • Heavy gauge reinforced wrap-around steel cabinet.............................................................................................. ✓ ✓ • Insulated blower compartment 0..................................................................................................................... ✓ ✓ • Service diagnostics with faults reported on IFC board..................................................................................... ✓ ✓ • Manual reset flame roll out switches................................................................................................................. ✓ ✓ • Multi-port in shot burners.................................................................................................................................. ✓ ✓ • Painted cabinet two tone color.......................................................................................................................... — ✓ • Service diagnostic capabilities.......................................................................................................................... ✓ ✓ • VorticaO II blower housing................................................................................................................................ ✓ ✓ • Slide out blower assembly on full-length rails................................................................................................... ✓ ✓ • Side return duct starter tabs ............................................................................................................................ ✓ ✓ • Silicon Nitride 120V hot surface igniter............................................................................................................ ✓ ✓ • Multiple heating blower speeds......................................................................................................................... ✓ ✓ • Meets requirements for 1%or less air leakage................................................................................................ ✓ ✓ • 20-year registered limited warranty on the heat exchanger& 10-year on all other functional parts(Residential Use)OO........................................................................ ✓ ✓ • Optional extended warranties available ...................................................................................................... ✓ ✓ O 14.5"cabinets do not have insulation 0 Registered Limited Warranty terms are available when you register within 60 days of installation.You can register online at americanstandardair.com or by phone at 800-554-8005;otherwise American Standard Heating&Air Conditioning's Base Limited Warranty terms will apply.Base Limited War- ranty information on specific products can be found on ASDealerNet.com. S8X1 S8X2 Table FUR-12-B—Optional Accessories 1 Stage 2 Stage Model Number Description Shipping Weight BAYLPSS400B..........LP Kit with Stainless Steel Burners........................................................................3 ....... (except 026) ✓ BAYLPSS410A..........LP Kit with Stainless Steel Burners........................................................................3 ....... S8X1A026 — BAYHANG .................Horizontal hanging kit.............................................................................................2 ....... ✓ ✓ BAYVENT200B..........Sidewall vent Termination Kit fo Direct vent furnaces.............................................2 ....... ✓ ✓ BAYSF1165A.............1"SlimFit Box with MERV 4 Filter(side return)......................................................5 ....... ✓ ✓ BAYFLTR203..............Horizontal Filter Kit for B Cabinets..........................................................................5 ....... ✓ ✓ BAYFLTR204..............Horizontal Filter Kit for C Cabinets..........................................................................5 ....... ✓ ✓ BAYFLTR205..............Horizontal Filter Kit for D Cabinets..........................................................................5 ....... ✓ ✓ BAYVENT600A..........Internal venting kit ................................................................................................11 ....... ✓ ✓ BAYVENT800B..........Masonry Chimney Vent Kit...................................................................................11 ....... ✓ ✓ PIP02095....................0 fitting for gas piping.............................................................................................1 ....... ✓ ✓ BAYLIFTB...................Dual return kit. B cabinet size extension................................................................8 ....... ✓ ✓ BAYLIFTC...................Dual return kit. C cabinet size extension................................................................9 ....... ✓ ✓ BAYLIFTD...................Dual return kit. D cabinet size extension................................................................9 ....... ✓ ✓ BAYBASE205.............Downflow subbase..................................................................................................8 ....... ✓ ✓ BAYFLTR206..............Filter Access Door Kit(Downflow only)...................................................................2 ....... ✓ ✓ For complete equipment/combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Effective 1/1/19 Guides and Limited Warranty Handbooks. FUR-12 14-1011-36 BUILT TO A HIGHER STANDARD'" Platinum 80, Gold 80% Gold 80, Silver 80h, A&Pr feat/ S*Idcrd® Silver 80, and American Standard 80 HEATING & AIR CONDITIONING Gas Furnaces Airflow Directions 0 0 0 cEEi 0 0 0 0 0 0 0 0 0 0 �0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 000000 / \\ 0 �,'Idll,�llr\ O DOWNFLOW AIR AIR 0 0 0 FLOW 0 0 0 0 0 0 0 0 0 FLOW o00000 0 0 0 0 0 0 0 0 0 0 0 0 UPFLOW o00000 0 0 0 0 0 o I 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 FLOW UPFLOW, DOWNFLOW, HORIZONTAL LEFT OR RIGHT FLOW 0000000000 OOooDo��00000 OO000Do 0�000 0BOB 0o0B00000 OODOOo0p�0 00g00��000000 00 �p00p0�0000�0 OOo0p0p�0o OD09 Boo000000 Op0000000 AIR UPFLOW DOWNFLOW AIR FLOW FLOW 000000l000 0 0 00000� o o 0p0p 0goo0o00o0000 0o 000 p000000000000 000o00p0p00� 0 000B00 00000 O Q��o 0 0 go pyr�� g000000 OO000 0000 OO0000000°000 OQ�o Note:The non-condensing,forty inch (40") height furnaces may be laid on either side for horizontal application.Connection brackets for coil/furnace alignment are included with the furnaces.The apex of the coil may point into or away from the airflow. For complete equipment/combination selections, installation instructions and warranty information, Effective 1/1/19 please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-13 14-1011-36 BUILT TO A HIGHER STANDARD" ,4AW?ay S wd&rd, Platinum 80 - Communicating HEATING & AIR CONDITIONING Two Stage ECM Variable Speed Table FUR-14-A-Platinum 80 Upflow/Horizontal Left or Right Induced Draft Gas Furnace(115/1/60)O02D Airflow Flue Uncrated Shipping Unit In Output(Btuh) ICSO Size Ignition Dimensions(in.) Weight Max Filter Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (lbs.) Fuse* Sizes** AUD2BO60ACV32B 3 48,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 136 15 17 x 25 x 1 AUD213080ACV3213 3 64,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1 AUD2CO80ACV42B 4 64,000 41,600 80.0 4 Silicon Nitride 40 x 21 x 28 155 15 17 x 25 x 1 AUD2B100ACV32B 3 80,000 52,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 148 15 17 x 25 x 1 AUD21C100ACV526 5 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 175 15 20 x 25 x 1 AUD2D120ACV52B 5 97,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 193 15 24 x 25 x 1 Platinum 80 Upflow AUD2D14OACV52B 5 111,00 72,800 80.0 4 Silicon Nitride 40 x 241/2 x 28 197 15 24 x 25 x 1 Table FUR-14-B-Platinum 80 Downflow/Horizontal Left or Right Induced Draft Gas Furnace(115/1/60)0®O Airflow Flue Uncrated Shipping Unit In Output(Btuh) ICSO Size Ignition Dimensions(in.) Weight Max Filter Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (lbs.) Fuse* Sizes ADD2BO60ACV32B 3 48,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 140 15 (2)14 x 20 x 1 ADD2BO80ACV32B 3 63,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2)14 x 20 x 1 ADD2C100ACV52B 5 81,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2)16 x 20 x 1 ADD2D120ACV52B 5 95,000 62,400 80.0 4 Silicon Nitride 40 x 24'/2 x 28 197 15 (2)16 x 20 x 1 Note:Variable speed furnaces should not be twinned and are not approved for twinning applications. O Must use communicating thermostat with AccuLinkTm II control. ®Field convertible to 24V non-communicating. Platinum 80 O Isolated Combustion System. Downflow O Direct drive variable speed motor is an ECM constant airflow blower motor. *Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. **For Upflow furnaces,the size is for a bottom return filter. Gold 80v - Two Stage ECM Variable Speed Table FUR-14-C-Gold 80v Upflow/Horizontal Left or Right Induced Draft Gas Furnace(115/1/60)O Airflow Flue Uncrated Shipping Unit In Output(Btuh) ICS® Size Ignition Dimensions(in.) Weight Max Filter Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (lbs.) Fuse* Sizes** AUD2B060A9V3VB 3 48,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 136 15 17 x 25 x 1 AUD2BO8OA9V3VB 3 64,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1 AUD2CO8OA9V4VB 4 64,000 41,600 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 17 x 25 x 1 AUD2C080B9V4V60 4 64,000 41,600 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 17 x 25 x 1 AUD2B100A9V3VB 3 80,000 52,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1 AUD2C100A9V5VB 5 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 20 20 x 25 x 1 Gold 80v AUD2C100B9V5VB0 5 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 20 20 x 25 x 1 Upflow AUD2D12OA9V5VB 5 97,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 193 20 24 x 25 x 1 AUD21D120139V5VBO 5 97,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 193 20 24 x 25 x 1 AUD2D14OA9V5VB 5 111,000 72,800 80.0 4 Silicon Nitride 40 x 241/2 x 28 197 20 24 x 25 x 1 Table FUR-14-D-Gold 80v Downflow/Horizontal Left or Right Induced Draft Gas Furnace(115/1/60)O Airflow Flue Uncrated Shipping Unit In Output(Btuh) ICS® Size Ignition Dimensions(in.) Weight Max Filter Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (lbs.) Fuse* Sizes ADD2B060A9V3VA 3 48,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 140 15 (2)14 x 20 x 1 ADD2B080A9V3VA 3 63,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2)14 x 20 x 1 ADD2C100A9V5VA 5 81,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 20 (2)16 x 20 x 1 ADD2D120A9V5VA 5 95,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 197 20 (2)16 x 20 x 1 Note:Variable speed furnaces should not be twinned and are not approved for twinning applications. O Model has high efficiency blower assembly. ®This furnace family uses a two speed draft inducer. O Isolated Combustion System. Gold 80v Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. Downflow For Upflow furnaces,the size is for a bottom return filter. For complete equipment/combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Effective 1/1/19 Guides and Limited Warranty Handbooks. FUR-14 14-1011-36 BUILT TO A HIGHER STANDARD' Amm?w s*Idwd. HEATING & AIR CONDITIONING Gold 80 - Two Stage Table FUR-15-A-Gold 80 Upflow/Horizontal,Left or Right Induced Draft Gas Furnace(115/1/60) Airflow Flue Uncrated Shipping Unit In Output(Btuh) ICSO Size Ignition Dimensions(in.) Weight Max Filter Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (lbs.) Fuse* Sizes** AUD2AO4OA9242A 2 32,000 20,800 80.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 17 x 25 x 1 AUD2AO6OA9362A 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 141/2 x 28 127 15 17 x 25 x 1 AUD26060A9362A 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 132 15 17 x 25 x 1 AUD26080A9362A 3 63,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1 AUD26080A9482A 4 63,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1 AUD26100A9362A 3 79,000 52,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 151 15 17 x 25 x 1 Gold 80 AUD2C100A9482A 4 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1 Upflow AUD2C100A9602A 5 80,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1 AUD2D100A9602A 5 80,000 52,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 175 20 24 x 25 x 1 AUD2C120A9542A 4.5 95,000 62,400 80.0 4 Silicon Nitride 40 x 21 x 28 176 20 20 x 25 x 1 AUD2D120A9602A 5 95,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1 AUD2D140A9602A 5 112,000 72,800 80.0 4 Silicon Nitride 40 x 241/2 x 28 192 20 24 x 25 x 1 Table FUR-15-B-Gold 80 Downflow/Horizontal Left or Right Induced Draft(115/1/60) Airflow Flue Uncrated Shipping Unit In Output(Btuh) ICSO Size Ignition Dimensions(in.) Weight Max Filter** Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (lbs.) Fuse* Sizes ADD2AO4OA9242A 2 32,000 20,800 80.0 4 Silicon Nitride 40 x 141/2 x 28 125 15 (2)14 x 20 x 1 ADD2AO6OA9362A 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 141/2 x 28 135 15 (2)14 x 20 x 1 ADD213060A9362A 3 48,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 140 15 (2)14 x 20 x 1 p ADD213080A9362A 3 64,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 152 15 (2)14 x 20 x 1 ADD213100A9482A 4 79,000 52,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 157 15 (2)14 x 20 x 1 ADD2C100A9482A 4 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2)16 x 20 x 1 Gold 80 ADD2C100A9602A 5 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 168 20 (2)16 x 20 x 1 Downflow ADD2D120A9602A 5 94,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 189 20 (2)16 x 20 x 1 ADD21D140A9602A 5 112,000 72,800 80.0 4 Silicon Nitride 40 x 241/2 x 28 196 20 (2)16 x 20 x 1 � Isolated Combustion System. *Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. Filters are not shipped with furnace. For Upflow furnaces,the size is for a bottom return filter. Silver 80h - Single Stage with ECM Multi-Speed Motor Table FUR-15-C-Silver 80h Upflow Horizontal,Left or Right Induced Draft Gas Furnace(11511/60) Airflow Nominal Flue Uncrated Shipping Unit In Output ICSO Size Ignition Dimensions(in.) Weight Max Filter Model No. Tons (Btuh) AFUE (in.) Device H x W x D (lbs.) Fuse* Sizes** AUD1A040A9H21 B 2 32,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 17 x 25 x 1 AUD1 B060A9H31 B 3 47,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 127 15 17 x 25 x 1 AUD1 B080A9H31 B 3 63,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1 AUD1 C080A9H41 B 4 64,000 80.0 4 Silicon Nitride 40 x 21 x 28 142 15 20 x 25 x 1 AUD1 B100A9H31 B 3 79,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 151 15 17 x 25 x 1 Silver 80h ALIM C100A9H51 B 5 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1 Upflow AUD1 D120A9H51 B 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1 AUD1 D140A9H51 B 5 111,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 193 20 24 x 25 x 1 Table FUR-15-D-Silver 80h Downflow Horizontal,Left or Right Induced Draft Gas Furnace(115/1/60) 0 Airflow Nominal Flue Uncrated Shipping Unit In Output ICSO Size Ignition Dimensions(in.) Weight Max Filter Model No. Tons (Btuh) AFUE (in.) Device H x W x D (lbs.) Fuse* Sizes ADD113060A9H31 B 3 48,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 129 15 (2)14 x 20 x 1 ADD16080A91-131 B 3 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2)14 x 20 x 1 V ADD1 C100A9H51 B 5 81,000 80.0 4 Silicon Nitride 40 x 21 x 28 167 20 (2)16 x 20 x 1 ADD1 D120A9H51 B 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 189 20 (2)16 x 20 x 1 Note: Silver 80h furnaces have constant torque ECM motors Silver 80h O Isolated Combustion System. Downflow *Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. '*For Upflow furnaces,the size is for a bottom return filter. For complete equipment/combination selections, installation instructions and warranty information, Effective 1/1/19 please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-15 14-1011-36 BUILT TO A HIGHER STANDARD" Amw " S7�tffdmd® HEATING & AIR CONDITIONING Silver 80 - Single Stage Table FUR-16-A—Silver 80 Upflow/Horizontal Left or Right Induced Draft Gas Furnace(115/1/60) Airflow Nominal Flue Uncrated Shipping Unit In Output ICSO Size Ignition Dimensions(in.) Weight Max Filter** Model No. Tons (Btuh) AFUE (in.) Device H x W x D (lbs.) Fuse* Sizes AUD1 A040A9241 B 2 32,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 17 x 25 x 1 AUD1 A040A9301 B 21/2 32,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 122 15 17 x 25 x 1 AUD1 A060A9241 B 2 47,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 124 15 17 x 25 x 1 AUD1 A060A9361 B 3 47,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 127 15 17 x 25 x 1 AUD1 B060A9361 B 3 47,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 132 15 17 x 25 x 1 Silver 80 AUD1 B080A9241 B 2 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 139 15 17 x 25 x 1 Upflow AUD1 B080A9361 B 3 63,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1 AUD1 B080A9481 B 4 64,000 80.0 4 Silicon Nitride 40 x 171h x 28 142 15 17 x 25 x 1 AUD1 C080A9601 B 5 64,000 80.0 4 Silicon Nitride 40 x 21 x 28 154 20 20 x 25 x 1 AUD1 B10OA9361 B 3 79,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 151 15 17 x 25 x 1 AUD1 Bl OOA9451 B 4 80,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 153 15 17 x 25 x 1 AUD1 Cl OOA9481 B 4 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1 AUD1 Cl OOA9601 B 5 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1 AUD1 Dl OOA9721 B 6 80,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 175 20 24 x 25 x 1 AUD1 C12OA9541 B 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 176 20 20 x 25 x 1 AUD1 D120A9601 B 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1 AUD1 D140A9601 B 5 111,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 193 20 24 x 25 x 1 Table FUR-16-13—Silver 80 Downflow/Horizontal Left or Right Induced Draft Gas Furnace(115/1/60) Airflow Nominal Flue Uncrated Shipping Unit In Output ICSO Size Ignition Dimensions(in.) Weight Max Filter** Model No. Tons (Btuh) AFUE (in.) Device H x W x D (lbs.) Fuse* Sizes ADD1A060A9241 B 2 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 129 15 (2)14 x 20 x 1 ADD1A060A9361 B 3 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 129 15 (2)14 x 20 x 1 V ADD16060A9361 B 3 48,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 134 15 (2)14 x 20 x 1 ADD1 B080A9361 B 3 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2)14 x 20 x 1 ADD1 B080A9451 B 4 64,000 80.0 4 Silicon Nitride 40 x 171h x 28 146 15 (2)14 x 20 x 1 Silver 80 ADD1 Bl OOA9451 B 4 80,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 156 15 (2)14 x 20 x 1 Downflow ADD1 Cl OOA9481 B 4 80,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2)16 x 20 x 1 ADD1 Cl OOA9541 B 5 81,000 80.0 4 Silicon Nitride 40 x 21 x 28 167 20 (2)16 x 20 x 1 ADD1 C120A9541 B 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 177 20 (2)16 x 20 x 1 ADD1 D120A9601 B 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 189 20 (2)16 x 20 x 1 ADD1 D140A9601 B 5 113,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 196 20 (2)16 x 20 x 1 O Isolated Combustion System. *Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. **Filters are not shipped with furnace. For Upf low furnaces,the size is for a bottom return filter. For complete equipment/combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Effective 1/1/19 Guides and Limited Warranty Handbooks. FUR-16 14-1011-36 BUILT TO A HIGHER STANDARD' Amm?w s*Idwd. HEATING & AIR CONDITIONING American Standard 80 - Single Stage Table FUR-17-A—AS80 Upflow/Horizontal Left or Right Induced Draft Gas Furnace(115/1/60) Airflow Nominal Flue Uncrated Shipping Unit In Output ICSO Size Ignition Dimensions(in.) Weight Max Filter** N-__ Model No. Tons (Btuh) AFUE (in.) Device H x W x D (lbs.) Fuse* Sizes ALI E 1 A040A9241 A 2 31,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 16 x 25 x 1 ALI E 1 A060A9241 A 2 47,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 124 15 16 x 25 x 1 ALI E 1 A060A9361 A 3 47,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 127 15 16 x 25 x 1 ALIE1 B060A9361 A 3 47,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 132 15 17 x 25 x 1 ALIE1 B080A9361 A 3 63,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1 ALIE1 B080A9481 A 4 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1 Amen Standard 80 can AUE1 Bl OOA9361 A 3 79,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 151 15 17 x 25 x 1 Upflow AUElClOOA9481A 4 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1 AUElClOOA9601A 5 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1 AUE1 D120A9601 A 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1 AUE1 D140A9601 A 5 111,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 193 20 24 x 25 x 1 Table FUR-17-13—AS80 Downflow/Horizontal Left or Right Induced Draft Gas Furnace(115/1/60) Airflow Nominal Flue Uncrated Shipping Unit In Output ICSO Size Ignition Dimensions(in.) Weight Max Filter** 0 Model No. Tons (Btuh) AFUE (in.) Device H x W x D (lbs.) Fuse* Sizes ADE1A060A9361A 3 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 129 15 (2)14 x 20 x 1 American ADE1 B060A9361A 3 48,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 134 15 (2)14 x 20 x 1 Standard 80 ADE1 B080A9451A 4 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2)14 x 20 x 1 Downflow ADE1 Bl OOA9451 A 4 80,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 156 15 (2)14 x 20 x 1 ADE1 Cl OOA9601A 5 81,000 80.0 4 Silicon Nitride 40 x 21 x 28 167 20 (2)16 x 20 x 1 ADE1 D120A9601A 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 189 20 (2)16 x 20 x 1 O Isolated Combustion System. * Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. **Filters are not shipped with furnace. For Upflow furnaces,the size is for a bottom return filter. For complete equipment/combination selections, installation instructions and warranty information, Effective 1/1/19 please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-17 14-1011-36 BUILT TO A HIGHER STANDARD" Platinum 80, Gold 80v, Gold 80, 74lxP ?Aq S*4.fd&rd, Silver 80h, Silver 80, and American HEATING & AIR CONDITIONING Standard 80 Convertible Gas Furnaces AUD2-ACV/ AUD2.9V AUD2/ AUD1-H/ AUD11 AUE1/ ADD2-ACV ADD2-9V ADD2 ADD1-H ADD1 ADE1 2 Stage 2 Stage 2 Stage 1 Stage 1 Stage 1 Stage 1 or 2 Pipe High Efficiency Table FU R-18-A—Features O • Comfort-RTm enhanced mode(cooling)............................................... ✓ ✓ — • AccuLfnkT""system.............................................................................. ✓ — — — — — • Can be connected in communicating or 24V non- communicating modes ......................................................................... ✓ — — — — — • User interface for system configuration- Easy to use navigation buttons and plain text for clear description of features........................................................................... ✓ — — — • Meets requirements for 2%or less air leakage..................................... ✓ ✓ — ✓ ✓ — • Adjustable heating fan off timing........................................................... ✓ ✓ ✓ ✓ ✓ ✓ • Alternate bottom/left/right return air(upflow models only) .................... ✓ ✓ ✓ ✓ ✓ ✓ • Attractive color accents......................................................................... ✓ ✓ ✓ ✓ ✓ — • Blower door safety switch...................................................................... ✓ ✓ ✓ ✓ ✓ ✓ • Bottom Panel(upflow models only)........................................................ ✓ ✓ ✓ ✓ ✓ — • Cleanable/reusable high velocity filters................................................. ✓ ✓ — ✓ — — • Common vent capability........................................................................ ✓ ✓ ✓ ✓ ✓ ✓ • Complete front service access.............................................................. ✓ ✓ ✓ ✓ ✓ ✓ • Direct drive,multi-speed(PSC)blower motor....................................... — ✓ — ✓ ✓ • Direct drive,multi-speed ECM blower motor(high efficiency)'............... — — — ✓ — — • Direct drive,variable speed ECM blower motor"................................. ✓ ✓ — — — — • Gasketed blower door........................................................................... ✓ ✓ ✓ ✓ ✓ — • Heavy gauge reinforced wrap-around steel cabinet............................. ✓ ✓ ✓ ✓ ✓ ✓ • Horizontal left/right without conversion required................................... ✓ ✓ ✓ ✓ ✓ ✓ • Humidifier/EAC hook-up capability ...................................................... ✓ ✓ ✓ ✓ ✓ — • Inner blower door panel(downflow models only).................................. ✓ ✓ ✓ ✓ ✓ ✓ • Insulated blower compartment 4 sides(upflow models only)................ ✓ ✓ ✓ ✓ ✓ — • Integrated solid state control w/self diagnostics.................................... ✓ ✓ ✓ ✓ ✓ ✓ • Left/right gas connection....................................................................... ✓ ✓ ✓ ✓ ✓ ✓ • Manual reset flame roll out switches..................................................... ✓ ✓ ✓ ✓ ✓ ✓ • Masonry Chimney Venting w/BAYVENT800B....................................... ✓ ✓ ✓ ✓ ✓ ✓ • Multi-port in shot burners...................................................................... ✓ ✓ ✓ ✓ ✓ ✓ • Painted cabinet single color.................................................................. — — — — ✓ • Perfect fit door latches(upflow models only) ......................................... ✓ ✓ ✓ ✓ ✓ — • Right or left hand side knock out for venting (downflow models only)......................................................................... ✓ ✓ ✓ ✓ ✓ ✓ • Selectable cooling fan off delay eliminates need for time delay relay................................................................................ O ✓ ✓ ✓ ✓ ✓ • Service diagnostic capabilities.............................................................. ✓ ✓ ✓ ✓ ✓ — • Service diagnostics with faults reported at the user interface................. ✓ — — — — — • Side return starter tabs(upflow models only)......................................... ✓ ✓ ✓ ✓ ✓ ✓ • Silicon Nitride hot surface igniter with adaptive heat up...................... ✓ ✓ ✓ ✓ ✓ ✓ • Single door filter access ....................................................................... ✓ ✓ ✓ ✓ ✓ — • Single wire twinning ............................................................................. — — ✓ ✓ ✓ — • Slide out blower assembly..................................................................... ✓ ✓ ✓ ✓ ✓ ✓ • 3-way vent option on downflow models (top,right or left) (downflow models only)......................................................................... — ✓ ✓ ✓ ✓ ✓ • 20 gauge aluminized steel heat exchanger.......................................... ✓ ✓ ✓ ✓ ✓ ✓ • 24 volt secondary fuse.......................................................................... — ✓ ✓ ✓ ✓ ✓ • Multiple heating blower speeds............................................................ ✓ ✓ ✓ — — • Two speed venter motor....................................................................... ✓ ✓ ✓ — — — • Two tone color....................................................................................... ✓ ✓ ✓ ✓ ✓ — • Two-stage gas valve.............................................................................. ✓ ✓ ✓ — — — • Registered limited lifetime heat exchanger warranty and 10-year on all other functional parts (Residential Use)o............................................................................ ✓ ✓ — — — — • Registered 20-year heat exchanger limited warranty and 10-year on all other functional parts(Residential Use).............................. ✓ ✓ ✓ ✓ • Optional extended warranties available........................................... ✓ ✓ ✓ ✓ ✓ ✓ Note:Variable speed furnaces should not be twinned and are not approved for twinning applications. O Registered Limited Warranty terms are available when you register within 60 days of installation.You can register online at americanstandardair.com or by phone at 800-554-8005;otherwise American Standard Heating&Air Conditioning's Base Limited Warranty terms will apply.Base Limited Warranty information on specific products can be found on ASDealerNet.com. ®Variable Speed O Selectable through thermostat 'Constant torque ECM(electronically commutated motor). —Constant airflow ECM(electronically commutated motor). For complete equipment/combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Effective 1/1/19 Guides and Limited Warranty Handbooks. FUR-18 14-1011-36 BUILT TO A HIGHER STANDARD'" Platinum 80, Gold 80v, Gold 80, 4`KM?jq S7�;qd�® Silver 80h, Silver 80, and American HEATING & AIR CONDITIONING Standard 80 Convertible Gas Furnaces AUD2-ACV/ADD2-ACV AUD2-9V/ 2 Stage ADD2-9V 2-Stg. Table FUR-19-A—Optional Accessories Variable Speed Variable Speed Model Number Description Shipping Weight BAYBASE205..........Downflow subbase for downf low models only.................8.................................................. ✓ ✓ BAYFLTR200...........Side Filter Rack(External)..............................................5.................................................. ✓ ✓ BAYFLTR203...........Filter kit horiz conversion for 17.5"cabinet.....................3.................................................. ✓ ✓ BAYFLTR204...........Filter kit horiz conversion for 21"cabinet........................3.................................................. ✓ ✓ BAYFLTR205...........Filter kit horiz conversion or 24.5"cabinet......................3.................................................. ✓ ✓ BAYFLTR206...........Filter Access Door Kit(Downflow only)...........................2.................................................. ✓ ✓ BAYFLTR3210 ......Cleanable filter for 21"cabinet upflow only.....................2.................................................. ✓ ✓ BAYFLTR3240 ......Cleanable filter for 24.5"cabinet upflow only..................2.................................................. ✓ ✓ BAYLPKT210B........Propane conversion kit....................................................1.................................................. ✓ ✓ BAYLPSS210B........LP Kit with Stainless Steel Burners.................................1.................................................. ✓ ✓ BAYRACK960A® ..Filter Rack Kit for upflow models only(internal)..............5.................................................. ✓ ✓ BAYVENT800B ......Masonry chimney vent kit................................................2.................................................. ✓ ✓ O Contains one(1)high velocity filter. ®Internal filter rack for side or bottom return air.Includes 17 x 25"cleanable filter for use in side return applications.Bottom return applications require different sizes of filters which are not included.Airflow requirements over 1800 CFM require filters on both sides or a side and bottom or bottom only. AUD2/ADD2 AUD1-H/ADD1-H AUDi/ADD1 AUEi/ADE1 2 Stage 1 Stage 1 Stage 1 Stage Table FUR-19-B—Optional Accessories High Efficiency Model Number Description ShippingWeight BAYBASE205..........Downflow subbase for downf low models only......................8......................... ✓ ✓ ✓ ✓ BAYFLTR200...........Side Filter Rack(External)...................................................5......................... ✓ ✓ ✓ — BAYFLTR203...........Filter kit horiz conversion for 17.5"cabinet..........................3......................... ✓ ✓ ✓ ✓ BAYFLTR204...........Filter kit horiz conversion for 21"cabinet.............................3......................... ✓ ✓ ✓ ✓ BAYFLTR205...........Filter kit horiz conversion or 24.5"cabinet...........................3......................... ✓ ✓ ✓ ✓ BAYFLTR206...........Filter Access Door Kit(Downflow only)................................2......................... ✓ ✓ ✓ ✓ BAYFLTR3170 ......Cleanable filter for 14.5"and 17.5 cabinet upflow only..........2......................... ✓ ✓ ✓ ✓ BAYFLTR3210 ......Cleanable filter for 21"cabinet upflow only..........................2......................... ✓ ✓ ✓ ✓ BAYFLTR3240 ......Cleanable filter for 24.5"cabinet upflow only.......................2......................... ✓ ✓ ✓ ✓ BAYLPKT210B........Propane conversion kit.........................................................1......................... ✓ ✓ ✓ ✓ BAYLPSS210B........LP Kit with Stainless Steel Burners......................................1......................... ✓ ✓ ✓ ✓ BAYRACK960A® ..Filter Rack Kit for upflow models only(internal)...................5......................... ✓ ✓ ✓ ✓ BAYVENT800B ......Masonry chimney vent kit.....................................................2......................... ✓ ✓ ✓ ✓ Note:Variable speed furnaces should not be twinned and are not approved for twinning applications. O Contains one(1)high velocity filter. ®Internal filter rack for side or bottom return air.Includes 17 x 25"cleanable filter for use in side return applications.Bottom return applications require different sizes of filters which are not included.Airflow requirements over 1800 CFM require filters on both sides or a side and bottom or bottom only. Special Use Furnace Accessories a Table FUR-19-C—High Altitude Pressure Switch 80% Model Shipping Number Description Used With Weight BAYHALT248 1 Switch AUDI,ADDI,AUEI,ADE1 2 BAYHALT249 1 Switch AUD-R-K,ADD-R-F,AUD2,ADD2 2 Bonnet TAYPLUS103A Table FUR-19-D—Dual Fuel Heat Pump Control Kit00 Switch Model Number Case Height Used With TAYPLUS103A.............Heat Pump Control Kit............Gas, LP.,Oil and Electric Furnaces TAYSTAT250B..............Outdoor Thermostat................TAYPLUS103A for Restricted Mode 0 Factory wired for non-restricted mode,can be wired for restricted mode. O Applicable for all furnaces with 35 VA or larger low voltage transformer(separate high voltage power not required). For complete equipment/combination selections, installation instructions and warranty information, Effective 1/1/19 please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-19 14-1011-36 BUILT TO A HIGHER STANDARD' Ama4w S7�zffd&rd® HEATING & AIR CONDITIONING High Efficiency Oil Furnaces Orrigarirri information Variable and Non-Variable Speed High Efficiency Oil Furnaces American Standard Oil Furnaces are available from your local distributor. For availability and support, contact your local distributor. c us �/STEM Intertek For complete equipment/combination selections, installation instructions and warranty information, Effective 1/1/19 please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks. FUR-20 14-1011-36 Permit#: 3090 Permit Date: 03/10/20 Permit Type: RESIDENTIAL MECHANICAL Project Name: Whitesitt Applicant Name: Blue Flame Heating &Air Applicant Address: 7116 220th St SW#I Applicant, City, State, Zip: Mountlake Terrace,WA 98043 Contact: Phone: 425-771-7139 Email: info@blueflamecomfort.com Scope of Work: Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 03/11/2020 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00621300003000 17730 31 ST DR NE WHITESITT 111 Single Family CARMEN Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# BLUE FLAME RODNEY CONSTRUCTION HEATINGANDAIR WALKER 425-771-7139 7116 220 ST SW CONTRACTOR COA 601 837 949 BLUE FLAME RODNEY CONSTRUCTION Labor&BLUEFFH825RM HEATING AND AIR WALKER 425-771-7139 7116 220 ST SW CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 04/29/2020 R00.FURNACE 04/29/2020 04/29/2020 Completed FINAL Fees Fee Description Notes Amount Inspection $75.00 Forced Air Heat fee per Btu $15.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Credit Card Service $4.20 Total $144.20 Attached Letters Date Letter Description 03/10/2020 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 03/11/2020 GEORGINA BARRIOS 79451217 $140.00 03/11/2020 79451217 CC Surcharge Raelynn Jones $4.20 Outstanding Balance $0.00 Uploaded Files Date File Name 03/11/2020 6377970-3090 Issued Permit.pdf 03/10/2020 6370480-3090 Apnlication.pdf 03/10/2020 6370481-3090 Specs.pdf