HomeMy WebLinkAbout16432 42nd Ave Ne_BLD3021_2026 CITY OF ARLINGTON
238 N. OLYMPIC AVE - ARLINGTON, WA, 98223
PHONE; (360) 403-3551
BUILDING PERMIT
Address:16432 42nd Ave NE Permit#:3021
Parcel 0:00866800020000 Valuation:,00
'OWNER `! ° ; APPLICANT CONTRACTOR
Name;GRAY DONNA A Name:[Company Name] Name:Brennan healing
Address:6613 50TEI DR NE Address:[Company Address] Address:4601 S 134th Place
City,Slate Zip: MARYSVILLE-,WA 99270 City,State Zip:Arlington,WA 98223 City,Slate Lip:Seattle,WA 98168
Phone: Phone:206-595.0267 Phone;206-248-7900
LIC: EXP:
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Nance:Brennan Heating Name;
Address:4601 S I34th PL Address:
City,State,Zip:Seattle,WA 98168 City,State,Zip:
Phone:206-248-7900 Phone:
LIC#:BRENNYIA97 I R9 EXP: 12/29/2021 LIC#: I:XP:
JOB DESCRIPTION •
PERMIT TYPE: Residential Mechanical CODE YEAR: 2015
STORIES: CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
1 AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED TI IFREBY;
NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF TILE sTATI?Or WASHINGToN RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR H1SAIL•R DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A ' TIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRCl10.
SAL TAX NOTICE:Sales tax relating to constnnction and eonsiruction material in th City of Arlington must be reponed on your sales lax return farm
and aca•City orndin o ;+3101. a► �I L � nb �� 2/5/2020
" a�
Signature Print Name Date tcleasnl Datc
CONDITIONS
3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated; use of
adhesive tapes are prohibited. Adhere to approved appliance. Approved job copy shall be onsite for
inspection. Call for final inspection.
I'HIS PERMIT AUI'I IORIZFS ONLY Tills WORK NOTL•D.TI IIS PI-RSIlT COVERS WORK 10 BE DONli ON PRIVAI'L:PROI'I'.RIN ONLY, ANY
CONSTRUCTION ON'rH1-PUBLIC DOMAIN(CURBS.SIDEWALKS,DRIVEWAYS,AIAKQUFES,EJC.)WILL REQUIRE SI;i, Ruu TE I'I-R411SSION.
PERMIT FEES
Date Description Fee Amount
02/0612020 InspectiorVRe-Inspection S75.00
02/0612020 Heat Purnp/Heat Exchangers $25.00
02/06/2020 Mechanical Residential Base $25.00
02/06/2020 Processing/Technology Fee S25.00
Total Due: $150.00
Total Payment: S0.0O
Balance Due: $150.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an Inspection please leave the following information:
Permit Number,1�,pe of Inspection being requested,and whether you prefer morning or afternoon
I
RESIDENTIAL MECHANICAL
PERMIT APPLICATION
Department of Community& Economic Development
City of Arlington• 18204 59th Ave NE • Arlington,WA 98223 •Phone(360)403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL
INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL
PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION.
Project Address: Y1 v�� q�7Z 3
Project Description: , r:7--+211 d, l C122)r,
Owner:
Address: l lLu:2 t17n6 Ave nF Ac'1 ✓1C{k.C�'1,W A aR7�
Phone: _(2-CIP) PlGr-) r)7 t fl_4 Email:
Applicant: Brennan Heating
Address:4601 S 134th PI Seattle 98168
Phone: 206-248-7900 Email: Jaimie@brennanheating.com
Applicant SignnturFti__
Electronic Signature if submitting on-line
1 hereby certify that the above information is correct and that the construction, installation for the
above mentioned property will be in accordance with the applicable laws of the City of Arlington
and the State of Washington.
CONTRACTOR INFORMATION
Contractor Name:Brennan Heating
Company: Brennan Heating
License Number:BRENNHA971 R9 Expiration: 12/29 )coo? I
Phone:206-248-7900 Email:Jaimie@brennanheating.com
STAFF USE ON Y Received
Permit#: a2� Accepted by: Date: 171:n 2Q2
r
RESIDENTIAL MECHANICAL
PERMIT APPLICATION
Department of Community& Economic Development
City of Arlington• 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551
SELECT ALL PROPOSED APPLIANCES
❑ Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ
❑� HePump ❑ Freestanding Stove ❑ Hydronic Piping
(_114k, s!)
❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System
❑ Boiler ❑ Gas Piping ❑ Storage Tank
❑ AC Unit ❑ Solid-Fuel Appliance ❑ Other
Gas Piping Information
Not Applicable: ❑
Pipe Material:
Pipe Size
Distance From Meter to Furthest Appliance:
Total BTU's of all Appliances:
• New gas piping requires a pressure test to hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper Combustion air and venting required for all appliances
• A shut-off valve Is required within 6 feet of all appliances
SPECIFICATIONS OUTDO UNIT4.., S F
Nominal Size-Tons 0.75 1.6 2
Outdoor Unit Model No. MLA009543 MLA012348 MLA018545 MLA024S4S
Ambient Temperature Operating Cooling —22-122 ---V--122 —22-122 —22-122
Range-°F Heating —22-86 —22-86 —22-86 —22-86
Sound Data(dBA) Cooling 52 52 56 57
Heating 57 57 59 60
Ref igerant Charge furnished(R410A) 3 lbs.3 oz. 3 lbs.3 oz. 4 lbs.3 oz. 5 lbs.7 oz.
Maximum line length with furnished charge-ft 25 25 25 25
Additional charge required per ft.-oz. 0.16 0.16 0.18 0.32
Compressor No.and Type Rotary Rotary Rotary Rotary
Refrigerant oil type Ester Oil VG74 Ester OU VG74 POE VG74 POE VG74
Refrigerant oil charge-oz. 16.9 16.9 22.7 22.7
Connections-In. Liquid/Gas pipe(flare) 1/413/8 1141112 114 1112 3/81518
Maximum refrigerant pipe length-ft. 82 82 98 164
Max.difference in level of indoor unit-fL 33 33 66 82
Outdoor (No.)Diameter-in. (1)17 (1)17 (1)19 (1)22
Fan Total air volume-crm 1120 1180 1355 2355
rpm 810 810 850 810
Outdoor Coll Number of rows 2 2 2 2
Fins per inch 18 18 18 19
Fin type Hydrophilic aluminium
Tube outside diameter-in. 3/8 3/6 1 3/8 3/8
Tube type Rifled copper tubing
Net face area-R2 4.73 4.73 5.19 8.16
Design Pressure PSIG 5501340 5601340 550/340 6501340
Shipping Data NeVShipping weight(lbs.) 88194 88194 1081115 1361149
ELECTRICAL DATA
Electrical Characteristics-80 Hz-1 Phase 208/230V 2081230V 2081230V 2081230V
'Maximum Overcurrent Protection(amps) 15 15 25 30
2 Minimum circuit ampacity 9 9 18 20
Compressor Rated load amps 5.25 5.65 12.3 14
Outdoor Fan Motor Rated load amps 0.38 0.38 0.42 0.5
Output-W 40 40 44 120
NOTE-Extremes of operating range are plus and minus 10%of line voltage.
'HACR type circult breaker or fuse.
Refer to National or Canadian Eleetrieal Cade manual to determine wire,fuse end disconnect size requirements.
Received
FEB 0 4 2020
Low Ambient Single Zone Mini-Split Systems/Page 15
SPECIFICATIONS - WALL-MOUNTED INDOOR/UNITS
Model No. I MWMAQS9S4 MWMA012S4 MWMA018S4 MWMA024S4
Nominal Tons 0,75 1 1.5 2
Power Supply-60 hz- 1 phase 208/230V 208/230V 208/230V 208/230V
Rated load amps 0.2 0.2 0.4 0.5
Output(W) 20 20 58 60
Room Temperature Cooling 62-90 62-90 62-90 62-90
Range(°F1
"-"'- ` Heating 32-86 32-t36 31-d6 32-86
Air Volume-cfm(High/Medium/Low) 370/270/195 370/275/200 530/410/295 6951625/485
Sound Data(dBA)-Low/Medium/High 26,5/33.4/41.7 28.6/35.8/45.1 30.9/36.3/46.2 35,1/44.5/51,7
Piping Connections-Liquid/Gas-o.d. -flare-in. 114/318 114/1/2 1/4/1/2 3/8/5/8
Drain connection o.d.-in. 1 1 1 1
Net/Shipping weights-lbs, 20/26 20/27 27/35 40/54
SPECIFICATIONS - CASSETTE INDOOR UNITS
Model No. � M22AOO9S4 M22AOi2S4 1122AO18S4 � M33AO24S4
Nominal Tons 0.75 1 1.5 2
Power Supply-60 hz-1 phase 2081230V 2081230V 206/230V 208/230V
Rated load amps 09 1.0 1 5 1.5
Output(W) 46 46 46 42
Room Temperaturo Cooling 62-90 62-90 62-90 62-90
Range( F) Heating 32-86 32-86 32-86 32-86
Air Volume-cfm(High/Medium/Low) 375/300/255 380/310/260 560/485/415 7001635/575
Sound Data (dBA)-Low/Medium/High 33/37/41 36/39/43 36/39/44 43/47/51
Piping Connections-Liquid/Gas-o.d. -flare-in. 1/4/3/8 1l4/112 1/4/ 1/2 3/8/5/8
Drain connection o.d.-in. 1 1 1 1-1/4
Net/Shipping weights -lbs. Body 32138 36 141 36/42 47/55
REQUIRED COMPONENTS - ORDERED SEPARATELY
Cassette Panel 13X04 13X04 13X04 13XOS
(MOSTAT62Q-1) (MOSTAT62O-1) (MOSFAT62O-1) (MOSTAT63O-1)
Net/Shipping weights-lbs. 6/ 10 6 110 6/10 12/18
Low Ambient Single Zone Mini-Spilt Systems/Page 16
^ 4YesM1in9-Sul,aP--d
kj Labor&Industries(fps://Ini.wa.gov).
Contractors
BRENNAN HEATING &A/C LLC
Owner or tradesperson 4601 S 134TH PL
Principals SEATTLE,WA 98168
ERDAHL,DARRIN PAUL,PARTNER/MEMBER 206-248-7900
KING County
Doing business as
BRENNAN HEATING&A/C LLC
WA UBI No. Business type
602 346 866 Limited Liability Company
Governing persons
DARRIN
P
ERDAHL
ERIC BEARDEMPHL;
License
Verify the contractor's active registration/license/certification(depending on trade)and any past violations.
Construction Contractor Active
Meets current requirements.
License specialties
GENERAL
License no.
BRENNHA971R9
Effective—expiration
12/29/2003-12/29/2021
Bond
FEDERATED MUTUAL INS CO $12,000.00
Bond account no
9127230
Received by L&I Effective date
11/04/2004 12/22/2004
Expiration date
Until Canceled
Insurance
Federated Mutual Ins Co $1,000,000.00
Policy no.
9820726
Received by L&I Effective date
05/29/2019 07/13/2015
Expiration date
0 7/1 312 0 2 0
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&1 Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts
may be recorded by other agencies.
License Violations
Infraction no.
PDOVE00515 Satisfied
Issue date RCW/WAC
01/26/2018 18.106.020
Violation city Violation amount
SEATTLE $250.00
Type of violation
PLUMBER INFRACTION
Description
Contractor employed a person to engage in the
trade of plumbing without a current
journeyman,specialty or trainee certificate,
temporary permit or medical gas endorsement
as required.
Certifications & Endorsements
OMWBE Certifications
No active certitications exist for this business.
Apprentice Training Agent
No active Washington registered apprentices exist for this business.Washington allows the use of apprentices
registered with Oregon or Montana.Contact the Oregon Bureau of Labor&Industries or Montana Department of Labor
&Industry to verify if this business has apprentices.
Workers' Comp
Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums.
This company has multiple workers'comp accounts.
Active accounts
Account no. Account is current.
803,761-08
Doing business as
BRENNAN HEATING&AIR CONDIT
Certificate of Workers'Comp Coverage 0
Track this contractor
Account no. Account is current.
803,761-18
Doing business as
PUYALLUP HEATING&AIR CONDITI
Certificate of Workers'Comp Coverage 0
Track this contractor o
Public Works Requirements
Verify the contractor is eligible to perform work on public works projects.
Required Training—Effective July 1,2019
Exempt from this requirement.
Contractor Strikes
No strikes have been issued against this contractor.
Contractors not allowed to bid
No debarments have been issued against this contractor.
Workplace Safety & Health
Check for any past safety and health violations found on jobsites this business was responsible for.
No inspections during the previous 6 year period.
CITY OF ARLINGTON
238 N. OLYMPIC AVE -ARLINGTON, WA. 98223
PHONE; (360) 403-3551
BUILDING PERMIT
Address:16432 42nd Ave NE Permit#:3021
Parcel#:00866800020000 Valuation:.00
OWNER APPLICANT _ CONTRACTOR
Name:GRAY DONNA A Name:[Company Name] Name:Brennan Heating
Address:6613 50TH DR NE Address:[Company Address] Address:4601 S 134th Place
City,State Zip:MARYSVILLE,WA 98270 City,State Zip:Arlington,WA 98223 City,State Zip:Seattle,WA 98168
Phone: Phone:206-595-0267 Phone:206-248-7900
LIC: EXP:
MECHANICAL CONTRACTOR PLUMBING CONTRACTO
Name:Brennan Heating Name:
Address:4601 S 134th PL Address:
City,State,Zip:Seattle,WA 98168 City,State,Zip:
Phone:206-248-7900 Phone:
LIC#:BFENNHA97IR9 EXP: 12/29/2021 LIC#: EXP:
JOB DESCRIPTION J= g
PERMIT TYPE: Residential Mechanical CODE YEAR: 2015
STORIES: CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;
NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110.
SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form
and coded City of Arlington#3101. 2/5/2020
Signature Print Name Date Released Date
CONDITIONS
3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated; use of
adhesive tapes are prohibited. Adhere to approved appliance. Approved job copy shall be onsite for
inspection. Call for final inspection.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
02/06/2020 Inspection/Re-Inspection $75.00
02/06/2020 Heat Pump/Heat Exchangers $25.00
02/06/2020 Mechanical Residential Base $25.00
02/06/2020 Processing/Technology Fee $25.00
Total Due: $150.00
Total Payment: $0.00
Balance Due: $150.00
CALL FOR INSPECTIONS r
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
CITY
OF ARLINGTON
238 N. OLYMPIC AVE - ARLINGTON, WA. 98223
PHONE; (360) 403-3551
BUILDING PERMIT
Address: 16432 42nd Ave NE Permit#:3021
Parcel#:00866800020000 Valuation:.00
OWNER APPLICANT CONTRACTOR
Name:GRAY DONNA A Name:[Company Name] Name:Brennan Heating
Address:6613 50TH DR NE Addrcss:[Company Address] Address:4601 S 134th Place
City,State Zip:MARYSVILLE,WA 98270 City,State Zip:Arlington,WA 98223 City,State Zip:Scattic,WA 98168
Phone: Phone:206-595-0267 Phone:206-248-7900
LIC: IiXP:
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name:Brennan lleating Name:
Address:4601 S 134th PL Address:
City,State,Zip:Seattle,WA 98168 City,State.Zip:
Phone:206-248-7900 Phone:
LIC#:BRENNHA97IR9 EXP: 12/29/2021 LIC#: F\P:
JOB DESCRIPTION
PERMIT TYPE: Residential Mechanical CODE YEAR: 2015
STORIES: CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUC I ION AND IN DOING THE WORK AU I I IORIZED f11EREB1;
NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE-AND APPROVAL OR
A ' TIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRCI10.
SAL TAX NOTICE:Spies tax relating to construction and construction material in th City of Arlington must be reported on your sales tax return form
and dcd�CityofAclin e #3101. at I L �1b � 2/5/2020
o� adiv�
Signature Print Nano Date cicascd llatc
CONDITIONS
3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated; use of
adhesive tapes are prohibited. Adhere to approved appliance. Approved job copy shall be onsite for
inspection. Call for final inspection.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DUNE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
02/06/2020 Inspection/Re-Inspection $75.00
02/06/2020 Heat Pump/Heat Exchangers S25.00
02/06/2020 Mechanical Residential Base $25.00
02/06/2020 Processing/Technology Fee S25.00
Total Due: $150.00
total PaNment: S0.00
Ba1:uu•e Due: S150.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
RESIDENTIAL MECHANICAL
4
PERMIT APPLICATION
Department of Community & Economic Development
City of Arlington • 18204 59th Ave NE • Arlington,WA 98223 • Phone (360)403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL
INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL
PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION.
Project Address: I U9 5z H 2=nd A\1c YAE
Project Description: T_Cet2L1 dotAe-:z�—�neDr 12� Y62 54�
Owner: -OCM)CQ r �,
Address: \ kr,(43��17y-)6 Ave
Phone: SCi�- f�7La� Email:
Applicant: Brennan Heating
Address: 4601 S 134th PI Seattle 98168
Phone: 206-248-7900 Email: Jaimie@brennanheating.com
Applicant Signature:
Electronic Signature if submitting on-line
l hereby certify that the above information is correct and that the construction, Installation for the
above mentioned property will be in accordance with the applicable laws of the City of Arlington
and the State of Washington.
CONTRACTOR INFORMATION
Contractor Name:Brennan Heating
Company: Brennan Heating
License Number:BRENNHA971 R9 Expiration: 12/29 001
Phone:206-248-7900 Email:Jaimie@brennanheating.com
STAFF USE ONLY
Permit #: Accepted by: Date: —
RESIDENTIAL MECHANICAL
PERMIT APPLICATION
Department of Community & Economic Development
City of Arlington • 18204 59th Ave NE • Arlington,WA 98223 • Phone(360)403-3551
SELECT ALL PROPOSED APPLIANCES
❑ Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ
He t Pump ❑ Freestanding Stove ❑ Hydronic Piping
4 k e 3'5)
❑ Type II Hood ❑ Commercial Cooking Appliance ❑ Pv System
❑ Boiler ❑ Gas Piping ❑ Storage Tank
❑ AC Unit ❑ Solid-Fuel Appliance ❑ Other
Gas Piping Information
Not Applicable: ❑
Pipe Material:
Pipe Size:
Distance From Meter to Furthest Appliance:
Total BTU's of all Appliances:
• New gas piping requires a pressure test to hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper Combustion air and venting required for all appliances
• A shut-off valve is required within 6 feet of all appliances
r
SPECIFICATIONS OUTDO
Nominal Size-Tons 0.76 1.6 2
Outdoor Unit Model No. MLA009S4S MLA012S4S MLA018S4S MLA024S4S
Ambient Temperature Operating Cooling —22-122 — - 222 —22-122 —22-122
Range-°F Heating —22-86 —22-86 —22-86 —22-86
Sound Data(dBA) Cooling 52 52 56 57
Heating 57 57 59 60
Refrigerant Charge furnished(R410A) 3 lbs.3 oz. 3 lbs.3 oz. 4 lbs.3 oz. 5 lbs.7 oz.
Maximum line length with fumished charge-ft. 25 25 25 25
Additional charge required per ft.-oz. 0.16 0.16 0.16 0.32
Compressor No.and Type Rotary Rotary Rotary Rotary
Refrigerant oil type Ester Oil VG74 Ester Oil VG74 POE VG74 POE VG74
Refrigerant oil charge-oz. 16.9 16.9 22.7 22.7
Connections-in. Liquid/Gas pipe(flare) 1/4/318 1/41112 1/411/2 3/8/518
Maximum refrigerant pipe length-ft. 82 82 98 164
Max.difference in level of indoor unit-ft. 33 33 66 82
Outdoor (No.)Diameter-in. (1) 17 (1)17 (1)1g (1)22
Fan Total air volume-cfm 1120 1180 1355 2355
rpm 810 810 850 810
Outdoor Coil Number of rows 2 2 2 2
Fins per inch 18 18 18 19
Fin type Hydrophilic aluminium
Tube outside diameter-in. 318 3/8 1 3/8 3/8
Tube type Rifled copper tubing
Net face area-ft.2 4.73 4.73 5.19 8.16
Design Pressure PSIG 550/340 550/340 550/340 5501340
Shipping Data Net/Shipping weight(lbs.) 88/94 88/94 1081115 1361149
ELECTRICAL DATA
r
Electrical Characteristics-60 Hz-1 Phase 208/230V 208/230V 2081230V 208/230V
' Maximum Overcurrent Protection(amps) 15 15 25 30
2 Minimum circuit ampacity, 9 9 18 20
Compressor Rated load amps 5.25 5.65 12.3 14
Outdoor Fan Motor Rated load amps 0.38 0.38 0.42 0.5
Output-W 40 40 44 120
NOTE-Extremes of operating range are plus and minus 10%of line voltage.
'HACR type circuit breaker or fuse.
Refer to National or Canadian Electrical Code manual to determine wire.fuse and disconnect sae requirements.
Law Ambient Single Zone Mini-Split Systems/Pape 15
SPECIFICATIONS - WALL-MOUNT 61NDOORUNITS
Model No. 4 MWMA012S4 MWMA018S4 MWMA024S4
Nominal Tons 0.75 1 1.5 2
Power Supply-60 hz- 1 phase 208/230V 208/230V 208/230V 208/230V
Rated load amps 0.2 0.2 0.4 0.5
Output(W) 20 20 58 60
Room Temperature Cooling 62-90 62-90 62-90 62-90
Range(°F) Heating 32-86 32-86 32-86 32-86
Air Volume-cfm(High/Medium/Low) 370/270/195 370/275/200 530/410/295 695/625/485
Sound Data(dBA)-Low/Medium/High 26.5/33.4/41.7 28.6/35.8/45.1 30.9/36.3/46.2 35.1/44.5/51.7
Piping Connections-Liquid/Gas-o.d. -flare-in. 1/4/3/8 1/4/1/2 1/4/1/2 3/8/5/8
Drain connection o.d.-in. 1 1 1 1
Net/Shipping weights-lbs. 20/26 20/27 27/35 40/54
SPECIFICATIONS - CASSETTE INDOOR UNITS
Model No. M22A009S4 M22A012S4 M22A018S4 M33A024S4
Nominal Tons 0.75 1 1.5 2
Power Supply-60 hz-1 phase 208/230V 208/230V 208/230V 208/230V
Rated load amps 0.9 1.0 1.5 1.5
Output(W) 46 46 46 42
Room Temperature Cooling 62-90 62-90 62-90 62-90
Range("F) Heating 32-86 32-86 32-86 32-86
Air Volume-cfm(High/Medium/Low) 375/300/255 380/310/260 560/485/415 700/635/575
Sound Data(dBA)-Low/Medium/High 33/37/41 36/39/43 36/39/44 43/47/51
Piping Connections-Liquid/Gas-o.d.-flare-in. 1/4/3/8 1/4/1/2 1/4/1/2 3/8/5/8
Drain connection o.d.-in. 1 1 1 1-1/4
Net/Shipping weights-lbs. Body 32/38 36/41 36/42 47/55
REQUIRED COMPONENTS - ORDERED SEPARATELY
Cassette Panel 13X04 13X04 13X04 13XO6
(MOSTAT62Q-1) (MOSTAT62Q-1) (MOSTAT62Q-1) (MOSTAT630-1)
Net/Shipping weights-lbs. 6110 6/10 6/10 12/18
Low Ambient Single Zone Mini-Split Systems/Page 16
Permit#: 3021
Permit Date: 02/05/20
Permit Type: RESIDENTIAL MECHANICAL
Project Name: Gray
Applicant Name: Brennan Heating
Applicant Address: 16432 42nd Ave NE
Applicant, City, State, Zip: Arlington,WA 98223
Contact: Jaimie How
Phone: 206-595-0267
Email:jaimie@brennanheating.com
Scope of Work: Install ductless HP
Valuation: 0.00
Square Feet: 0
Number of Stories: 0
Construction Type:
Occupancy Group:
ID Code:
Permit Issued: 02/07/2020
Permit Expires:
Form Permit Type:
Status: COMPLETE
Assigned To: Raelynn Jones
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
141 Single Family
00866800020000 16432 42ND AVE NE GRAY DONNA A Residence
Condominium
Detached
Contractors
Contractor Primary Contact Phone Address Contractor Type License License#
Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL COA 602 346 866
CONTRACTOR
Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL Labor d BRENNHA971R9
CONTRACTOR Industri anes
Fees
Fee Description Notes Amount
Inspection $75.00
Heat Pump/Heat Exchangers $25.00
Mechanical Base Permit Fee $25.00
Processing/Technology $25.00
Credit Card Service $4.50
Total $154.50
Attached Letters
Date Letter Description
02/05/2020 Building Permit
Payments
Date Paid By Description Payment Type Accepted By Amount
02/06/2020 Brennan Heating 78914543 $150.00
02/06/2020 78914543 CC Surcharge Raelynn Jones $4.50
Outstanding Balance $0.00
Uploaded Files
Date File Name
02/05/2020 6204928-GrayMechApp.pdf