Loading...
HomeMy WebLinkAbout19010 46th Ave Ne_BLD5176_2024 Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551 Page 1 of 1 Permit Number: Permit Type: Address/Parcel: Completed (Month/Year): Land Use ˆ Notice of Decision ˆ Staff Report ˆ Application ˆ Narrative ˆ Legal Description ˆ Vicinity Map ˆ Site Plan ˆ Landscape Plan ˆ Complete Streets Checklist ˆ Traffic Impact Analysis ˆ Snohomish County Traffic Mitigation Offer ˆ WSDOT Traffic Offer Form ˆ Tree Survey ˆ Stormwater Drainage Report ˆ Geotech Report ˆ Critical Area Evaluation Form ˆ SEPA Checklist ˆ Public Notice Material ˆ Noticing and Related Documents ˆ Water / Sewer Availability Certificate ˆ Unanticipated Discovery Plan Form ˆ Aerial Photo of Site ˆ Proposed Building Materials ˆ Lighting Plans and Lighting Cut Sheets ˆ Color Elevations ˆ Design Matrix ˆ Plat Map ˆ Title Report ˆ Lot Closures ˆ Preliminary Civil Plans ˆ Archaeological Survey o Confidential Documents. Contact the City to obtain. ˆ Topography (Existing Conditions) ˆ CC&R’s ˆ Deeds / Easements / Conveyances /Dedications ˆ Developer’s Agreement ˆ Recorded Copies ˆ Bonding or Assignment of Funds o Confidential Documents. Contact the City to obtain. ˆ Letters and Project Documents ˆ Other: Civil ˆ Issued Permit ˆ Application ˆ Other Applications ˆ Construction Calculation Worksheet ˆ Approved Plans ˆ Review Comment Form ˆ Letters and Project Documents ˆ Other Agency Permits ˆ Reports: o Drainage Report Pg: o Stormwater Pg: o Geotech Pg: o All Other Reports ˆ SEPA and Noticing Materials ˆ Inspections ˆ As-Builts ˆ Other: Building ˆ Issued Permit ˆ Application ˆ Additional Applications ˆ Approved Plans ˆ Site Plan ˆ Letters and Project Documents ˆ Calculations ˆ Project Specification Manuals ˆ Reports ˆ Certificate of Occupancy ˆ Inspections ˆ Other: BLD5176 Residential Zoning Verification 19010 46th Ave Ne January 2024 ✔ ✔ ✔ 19010 46TH AVE NE , ARLINGTON, WA 98223-4789 35,000 14 00955700001400 CONVERT GARAGE INTO (2) BEDROOMS & STORAGE. MAMBO THERESE 207 272 5798 19010 46TH AVE NE , ARLINGTON, WA 98223-4789 202 272 5798 WA 98223ARLINGTON19010 46TH AVE NE HOME OWNER DOING THE WORK 0 0 0 0 7405 2591 2416 33 GEORGE NGANGA 2/21/2023 11776 1776 1776 0 0 640 35,000 0095570000140014 MAMBO THERESE k.tan76@yahoo.com 207 272 5798 207 272 5798 19010 46TH AVE NE ARLINGTON WA 98223 HOME OWNER DOING THE WORK CONVERT GARAGE INTO (2) BEDROOMS & STORAGE. REMODEL SF IS 640SF 19010 46TH AVE NE , ARLINGTON, WA 98223-4789 2 $ 50 1 $15 $ 190 GEORGE NGANGA 2/21/2023 INTERIOR WALL FRAMING ELEVATION SCALE: NONE1 2x4 STUDS 16" O.C. Header Sill Plate Double 2x8 w/ plywood spacer EXTERIOR WALL FRAMING ELEVATION(4x) SCALE: NONE ROUGH OPENING Section through window rough opening studs 16" O.C. TYP KING STUD BLOCKING JACK STUDS R-10 rigid foam insulation 2B 1 ST FLOOR 1760 SF DRIVEWAY 1 SITE PLAN SCALE: 1"=10'-0"1 N 46TH AVE NE CNRVT SPACE 640 SF SIDEWALK SIDEWALK GRASS VERGEGRASS VERGE Header Blocking Double 2x6 w/ plywood spacer DOOR FRAMING ELEVATION SCALE: NONE3 Section through window rough opening studs 16" O.C. TYP KING STUD Jack stud VICINITY PLAN SCALE: NONE2 Scale Date Drawn By Checked By Project Number Varies CS - GM No.Description Date A001 SITE & VICINITY PLANS & ELEVATIONS THERESE GARAGE REMODEL 19010 46TH AVE NE ARLINGTON, WA 98371 CSLdesigns21@gmail.com CSL DESIGNS 1/13/2022 LIVING ROOM KITCHEN BEDROOM A BEDROOM B BEDROOM C BEDROOM D GARAGE CLOSET C C CLOSET C DECK BATH A BATH B DINING ROOM SD SD CO 2 SD 2 SD SD SD CO FRAMING SPECIFICATIONS FRAMING LUMBER SHALL BE S-DRY, KD, OR WC-19, AND GRADED AND MARKED IN CONFORMANCE WITH WCLIB STANDARD "GRADING RULES FOR WEST COAST LUMBER NO. 17", OR WWPA STANDARD, "WESTERN LUMBER GRADING RULES 2011". FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS AND BEAMS (2X & 3X MEMBERS) HEM-FIR NO. 2 MINIIMUM BASE VALUE, FB - 850PSI (4X MEMBERS) DOUGLAS FIR-LARCH NO. 1 MINIIMUM BASE VALUE, FB - 1000PSI STUDS & MISC. FRAMING DOUGLAS FIR-LARCH OR HEM-FIR NO. 2 PLATES DOUGLAS FIR-LARCH WOOD FASTENERS A.NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: SIZE LENGTH DIAMETER 8D 2- 1/2" 0.131" 16D 3-1/2" 0.135" IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION ) FOR REVIEW. NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTER SINKING PERMITTED. TOE-NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGRESS WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END. B.ALL BOLTS IN WOOD SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG BOLTS SHALL CONFORM TO THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION WITH A LEAD BORE HOLE OF 60 TO 70 PERCENT OF THE SHANK DIAMETER. LEAD HOLES ARE NOT REQUIRED FOR 3/8" AND SMALLER LAG SCREWS. WOOD FRAMING NOTES--THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS: A.ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE, THE AITC "TIMBER CONSTRUCTION MANUAL" AND THE AF&PA "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION". MINIMUM NAILING UNLESS OTHERWISE NOTED, SHALL CONFORM TO IRC TABLE R602.3.(1). COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH ARCHITECTURAL DRAWINGS. B.WALL FRAMING : REFER TO ARCHITECTURAL DRAWINGS FOR THE SIZE OF ALL WALLS. ALL STUDS SHALL BE SPACED AT 16" O.C. UNO. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS, AND AT BEAM OR HEADER BEARING LOCATIONS. TWO 2X8 HEADERS SHALL BE PROVIDED OVER ALL OPENINGS NOT OTHERWISE NOTED. SOLID BLOCKING FOR WOOD COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. PROVIDE CONTINUOUS SOLID BLOCKING AT MID-HEIGHT OF ALL STUD WALLS OVER 10'-0" IN HEIGHT. ALL WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE TO EACH STUD WITH 16D NAILS. AND TOENAIL OR END NAIL EACH STUD TO BOTTOM PLATE WITH 16D NAILS. FACE NAIL DOUBLE TOP PLATE WITH 16D @12" O.C. AND LAP MINIMUM 4'-0" AT JOINTS AND PROVIDE EIGHT 16D NAILS @4" O.C. EACH SIDE JOINT. ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH TWO ROWS OF 16D NAILS @ 12" ON-CENTER, OR ATTACHED TO CONCRETE BELOW WITH 5/8" DIAMETER ANCHOR BOLTS @ 4'-0" ON-CENTER EMBEDDED 7" MINIMUM, UNLESS INDICATED OTHERWISE. INDIVIDUAL MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH TWO ROWS OF 16D @12" ON-CENTER. UNLESS OTHERWISE NOTED, GYPSUM WALLBOARD SHALL BE FASTENED TO THE INTERIOR SURFACE OF ALL STUDS AND PLATES WITH NO. 6 X 1-1/4" TYPE S OR W SCREWS @ 8" ON-CENTER. UNLESS INDICATED OTHERWISE, 1/2" (NOMINAL) APA RATED SHEATHING (SPAN RATING 24/0) SHALL BE NAILED TO ALL EXTERIOR SURFACES WITH 8D NAILS @ 6" ON-CENTER AT PANEL EDGES AND TOP AND BOTTOM PLATES (BLOCK UN-SUPPORTED EDGES) AND TO ALL INTERMEDIATE STUDS AND BLOCKING WITH 8D NAILS @ 12" ON-CENTER ALLOW 1/8" SPACING AT ALL PANEL EDGES AND PANEL ENDS. BORED OR DRILLED HOLES: MAY NOT EXCEED 60% OF STUD WIDTH (IF DRILLED OVER 40% MUST BE DOUBLED) SHALL NOT BE CLOSER THAN 5/8" TO EDGE OF STUD SHALL NOT BE IN THE SAME SECTION AS A CUT OR NOTCH (EXCEPTIONS R602.6; DETAILS: FIGURES R602.6(1),R602.6.2(2),R602.6.1 FIREBLOCKING: IN CONCEALED SPACES OF STUD WALLS & PARTITIONS AS FOLLOWS: 1.VERTICALLY AT CEILINGS AND WALLS 2.HORIZONTALLY AT MAX. 10' INTERVALS 3.ALL INTERCONNECTIONS SUCH AS SOFFITS, DROP CEILINGS, COVE CEILINGS. 4.IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT TOP & BOTTOM OF RUN 5.OPENINGS AROUND VENTS/PIPES/DUCTS AT FLOOR AND CEILING LEVELS FIRE BLOCKING MATERIALS SHALL BE CONSISTENT WITH R302.11.1 LOOSE FILL MATERIAL IS NOT ALLOWED NOTE: ALL FIRE BLOCKS AND DRAFT BLOCKS REQUIRED TO BE INSTALLED PRIOR TO FRAMING INSPECTION. DOOR HANDLES: OPERABLE PARTS OF DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER DEVICES INSTALLED IN ADULT FAMILY HOMES SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. POCKET DOORS SHALL HAVE GRASPABLE HARDWARE AVAILABLE WHEN IN THE CLOSED OR OPEN POSITION.SCALE: 1/4"=1'-0"1 FLOOR PLAN - EXISTING SCALE: 1/4"=1'-0"1 N FUR WH Scale Date Drawn By Checked By Project Number Varies - GM No.Description Date A002 EXISTING PLANS & SPECIFICATIONS CSLdesigns21@gmail.com CSL DESIGNS THERESE GARAGE REMODEL 19010 46TH AVE NE ARLINGTON, WA 98371 1/13/2022 CS LIVING ROOM KITCHEN BEDROOM A BEDROOM B BEDROOM C BEDROOM D CLOSET C C CLOSET C DECK BATH A BATH B DINING ROOM SD SD CO SD SD SD SD CO SCALE: 1/4"=1'-0"1 FLOOR PLAN - PROPOSED SCALE: 1/4"=1'-0"1 N FUR WH 2 SD CLOSET BEDROOM E 182 SF BEDROOM F 114 SF STORAGE CLOSET 2 SD SCOPE OF WORK: CONVERT GARAGE INTO (2) BEDROOMS & STORAGE.1. CONSTRUCTION NOTES: INSTALL 5200 BTUH HEAT PUMP. HEAT PUMP SHALL A MINIMUM EFFICIENCY OF 8.2 HSPF FOR HEATING MODE. INSTALL NEW SMOKE DETECTORS. PROVIDE COMBINED FIRE AND SMOKE DETECTOR, C.O. FUR OUT GARAGE WALLS AS NEEDED TO MAKE ROOM FOR 2x8 STUDS AND INSTALL R-21 +R12 INSULATION. ROUTE 12" DUCT UP TO ATTIC, TERMINATE WITH GOOSENECK, PROVIDE HIGH AND LOW OPENING INTO UTILITY ROOM. SEE SHEET A004 FOR FURNACE COMBUSTION AIR DETAIL. INSULATE ATTIC TO R-49. PROVIDE 105 CFM WHOLE HOUSE EXHAUST FAN FV-0511VKL2 OR EQUAL. CONNECT CONNECT TO 4" EXHAUST DUCT AND ROUTE ABOVE CEILING TO THE EXTERIOR .TERMINATE WITH A VENT CAP.PROVIDE R-7 INSULATION FOR DUCTWORK IN ATTIC. 1. 2. 3. 4. 5. 6. 7. 1. 2. 3. 4. GENERAL NOTES: ALL SMOKE ALARMS AND COMBINED FIRE AND SMOKE ALARMS ARE TO BE INTERCONNECTED PER IRC R314.2.2 & R315.2.2 INTERIOR NON-LOAD BEARING WALLS DO NOT REQUIRE STRUCTURAL HEADER. PROVIDE INSULATION FOR ALL HOT WATER PIPING WITH A MINIMUM THERMAL RESISTANCE (R-VALUE) OF R-3. REFERENCE BORED OR DRILLED HOLES & FIRE BLOCKING NOTATIONS ON SHEET A002. 1/2" GYPSUM BOARD SEPARATION INSTALLED ON GARAGE SIDE. STRUCTURAL MEMBERS SUPPORTING HORIZONTAL SEPARATION REQUIRES ½” GYPSUM BOARD (INCLUDING ALL BEARING WALLS, POSTS, COLUMNS, ETC..) FIRE BLOCKING IS REQUIRED FOR ALL OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES TO RESIST PASSAGE OF FLAMES AND COMBUSTION. FRAME WALLS, INSTALL DOORS, WINDOWS PER ELEVATION DETAILS ON SHEET A001 AND PER FRAMING SPECIFICATIONS ON SHEET A002. 5. 6. ·2018 INTERNATIONAL RESIDENTIAL CODE(IRC), EDITION & WAC 51-51 ·2018 UNIFORM PLUMBING CODE (UPC),EDITION & WAC 51-56, 51-57 ·2018 WASHINGTON STATE ENERGY CODE RESIDENTIAL (WSEC) INTERIOR WALL ASSEMBLY DETAIL 1/2" Gypsum wall board 2x4 STUD @ 16" O.C. 1/2" Gypsum wall board 1 1 (N) 4'x 4' window w/ (2)2x8 Header, 0.22 U-value, 5.7 SF min opening. Height from Floor to window net clear opening shall be a max of 44".(TYP. 3) SUMMARY OF TABLE R406.2 OPTION FUEL NORMALIZATION DESCRIPTION CREDIT(S) 1.5 EFFICIENT BUILDING ENVELOPE 1.5: 2.0 Vertical fenestration U=0.22 Wood frame wall R-21 int plus R-12 floor R10 2 HEAT PUMP 1.0 OPTION ENERGY CREDITS DESCRIPTION CREDIT(S) Garage door to remain Garage door to remain 5 22x30 ATTIC ACCESS 7 7. Scale Date Drawn By Checked By Project Number No.Description Date A003 PROPOSED PLAN - GM Varies - CSLdesigns21@gmail.com CSL DESIGNS THERESE GARAGE REMODEL 19010 46TH AVE NE ARLINGTON, WA 98371 1/3/2022 CS Minimum 1" Insulation baffles R-49 Insulation 5/8" Gypsum wall board Double 2x6 Top plate 1/2" Gypsum wall board R-21 Insulation plus R-12 3/4" T&G Plywood or Equiv subfloor glued & nailed Floor Joist per plan 1 Existing garage door to remain. Vented blocking water resistive barrier(tyvek) Existing roof EXTERIOR WALL FRAMING DETAIL SCALE: NONE 2x6 Install 3 4" rigid foam board on the inside of garage door. Protect R-21 insulation from moisture by using spray foam where there are gaps. R-10 Insulation Concrete curb per detail #2 on this page 3 SILL PLATE ATTACHMENT DETAIL SCALE: NONE Sill plate attached per 2018 IRC R317,R318,R403.1.6,R602.11.1 FURNACE DUCT Ceiling Floor 12" Duct with high and low 6" opening Roof FURNACE COMBUSTION AIR DETAIL NOTE: INSTALL DUCTWORK PER 2018 IRC CHAPTER 16 2x6 P.T. plate Existing driveway Frame in garage door opening with 2x6 studs @16" o.c. with 1/2" sheathing on the exterior. Existing header to remain in the opening. 2 Existing garage floor CURB DETAIL SCALE: NONE 2x10 joist 2x10 P.T. Rim joist 4x2 P.T. Sleeper set in mastic to foundation with simpson "titen" concrete screw & 3"x3"x1/4" seismic washer 4' O.C.imbed 3" min. 2x10 JOIST RIP AS NECESSARY (E)Garage door New curb. Min 6" wide and 6" high. Max height equal to height of existing stemwall. Insulate as required. 1/2" Anchor bolts @6ft o.c. embed 7" min. into curb. Use screw anchors into slab where curb is less than 7" tall.3"x3"x0.225" plate washer SCALE: 1/4"=1'-0"1 GARAGE FLOOR FRAMING PLAN SCALE: 1/4"=1'-0"1 FUR WH 6 mil vapor barrier required on top of slab. Lap splices 12" min and 6" min up the sides 2x10 Floor joists attach to ledger w/ joist hangers Joist lumber species shall be hem-fir/doug fir NO. 2 2x10 P.T. Rim joist (N) curb per detail 2 on sheet A004 For exterior wall installation refer detail #1 on sheet A004 3/4" Plywood floor sheathing species group 4 R-10 Rigid Insulation below sleepers. (TYP.) 4x2 P.T. Mid-span support that is anchored to the concrete slab per curb detail #2 on sheet A004.(TYP. 3) 2x10 P.T. ledger board w/ 1 2" x4 lag screw & washer. See lag screw placement detail on sheet A004. 2x10 Blocking every 48" Max, staggered Scale Date Drawn By Checked By Project Number No.Description Date A004 DETAILS & GARAGE FLOOR FRAMING PLAN - GM Varies - CSLdesigns21@gmail.com CSL DESIGNS THERESE GARAGE REMODEL 19010 46TH AVE NE ARLINGTON, WA 98371 1/13/2022 CS Window, Skylight and Door Schedule Project Information Contact Information Width Height Ref. U-factor Qt. Feet Inch Feet Inch Area UA Exempt Swinging Door (24 sq. ft. max.)WSEC 0.00 0 0 0 0.0 0.00 0.0 0.00 Vertical Fenestration (Windows and doors) Component Width Height Description Ref. U-factor Qt. Feet Inch Feet Inch Area UA WSEC 0.22 3 4 0 4 0 48.0 10.56 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Exempt Glazed Fenestration (15 sq. ft. max.) Therese Remodel CSL Designs 19010 46TH AVE NE 2065486798 ARLINGTON, WA 98371 Windows 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Vertical Fenestration Area and UA 48.0 10.56 Vertical Fenestration Area Weighted U = UA/Area 0.22 Overhead Glazing (Skylights) Component Width Height Description Ref. U-factor Qt. Feet Inch Feet Inch Area UA 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Overhead Glazing Area and UA 0.0 0.00 Overhead Glazing Area Weighted U = UA/Area 0.00 48.0 10.56Total Sum of Fenestration Area and UA (for heating system sizing calculations) Simple Heating System Size: Washington State Project Information Contact Information Heating System Type: To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (∆T) 47 ∆T = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 640 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft)7.0 4,480 Glazing and Doors U-Factor X Area = UA Instructions 0.220 48 10.56 Skylights U-Factor X Area = UA Instructions 0.50 --- Insulation Attic U-Factor X Area = UA Instructions 0.026 640 16.64 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions ---________ Above Grade Walls (see Figure 1)U-Factor X Area UA Instructions 0.032 462 14.78 Floors U-Factor X Area UA Instructions --- 0 ________ Below Grade Walls (see Figure 1)U-Factor X Area UA Instructions No selection --- Slab Below Grade (see Figure 1)F-Factor X Length UA Instructions No selection --- Slab on Grade (see Figure 1)F-Factor X Length UA Instructions 0.360 66 23.76 Location of Ducts Instructions Duct Leakage Coefficient 1.10 Sum of UA 65.74 Envelope Heat Load 3,090 Btu / Hour Sum of UA x ∆T Air Leakage Heat Load 2,274 Btu / Hour Volume x 0.6 x ∆T x 0.018 Building Design Heat Load 5,364 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 5,900 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 7,376 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop-down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Therese Remodel 19010 46TH AVE NE ARLINGTON, WA 98371 CSL Designs 2065486798 Above Grade Below Grade Figure 1. All Other Systems Heat Pump (07/01/13) 2018 Washington State Energy Code ResidentialPrescriptive Energy Code Compliancefor All Climate Zones in Washington Prescriptive Path Single Family 2018 Washington State Energy Code-R 1 Project Information Contact Information Instructions: This single-family project will use the requirements of the Prescriptive Path below and incorporate the minimum values listed. Based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative Date n/a n/a a R-values are minimums.U-factors and SHGC are maximums. When insulation is installed in a cavity that is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. c "10/15/21 +5TB" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21 +5TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB" means R-5 thermal break between floor slab and basement wall. g For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for climate zone 5 of ICC 400. h Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard framing 16 inches on center, 78% of the wall cavity insulated and headers insulated with a minimum of R-10 insulation. These requirements apply to all IRC building types, including detached one- and two-family dwellings and multiple single-family dwellings (townhouses). Provide all information from the following tables as building permit drawings: Table R402.1 - Insulation and Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 406.3 - Energy Credits. All Climate Zones (Table R402.1.1) R-Value a U-Factor a Fenestration U-Factor b n/a 0.30 Skylight U-Factor b n/a 0.50 Glazed Fenestration SHGC b,e d R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1. e f R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall meet the requirements for thermal barriers protecting foam plastics. For single rafter- or joist-vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth extends over the top plate of the exterior wall. Ceiling e 49 0.026 Wood Frame Wall g,h 21 int 0.056 Floor 30 0.029 Below Grade Wall c,h 10/15/21 int + TB 0.042 Slab d,f R-Value & Depth 10, 2 ft n/a Single Family New & Additions (effective February 1, 2021) Version 1.0 02/21/2023 THERESE GARAGE REMODEL 19010 46TH AVE NE , ARLINGTON, WA 98223-4789 CSL DESIGNS 206 548 6798 2018 Washington State Energy Code ResidentialPrescriptive Energy Code Compliance for All Climate Zones in Washington Prescriptive Path Single Family 2018 Washington State Energy Code-R 2 2.Medium Dwelling Unit: 6 credits All dwelling units that are not included in #1 or #3 3.Large Dwelling Unit: 7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4.Additions less than 500 square feet: 1.5 credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4. Summary of Table R406.2 Heating Options Fuel Normalization Descriptions Credits - select ONE heating option User Notes 4 DHP with zonal electric resistance per option 3.4 0.5 5 All other heating systems -1.0 Energy Options Energy Credit Option Descriptions Credits - select ONE energy option from each category d 1.3 Efficient Building Envelope 0.5 1.5 Efficient Building Envelope 2.0 1.6 Efficient Building Envelope 3.0 1.7 Efficient Building Envelope 0.5 2.1 Air Leakage Control and Efficient Ventilation 0.5 2.2 Air Leakage Control and Efficient Ventilation 1.0 2.3 Air Leakage Control and Efficient Ventilation 1.5 2.4 Air Leakage Control and Efficient Ventilation 2.0 3.1a High Efficiency HVAC 1.0 3.2 High Efficiency HVAC 1.0 3.3a High Efficiency HVAC 1.5 3.4 High Efficiency HVAC 1.5 3.5 High Efficiency HVAC 1.5 3.6a High Efficiency HVAC 2.0 4.1 High Efficiency HVAC Distribution System 0.5 4.2 High Efficiency HVAC Distribution System 1.0 1.2 Efficient Building Envelope 1.0 1 Combustion heating minimum NAECAb 0.0 1.1 Efficient Building Envelope 0.5 1.4 Efficient Building Envelope 1.0 2 Heat pumpc 1.0 3 Electric resistance heat only - furnace or zonal -1.0 1.Small Dwelling Unit: 3 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. Single Family New & Additions (effective February 1, 2021) Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of credits. To claim this credit, the building permit drawings shall specify the option selected and the maximum tested building air leakage, and show the qualifying ventilation system and its control sequence of operation. 2018 Washington State Energy Code ResidentialPrescriptive Energy Code Compliance for All Climate Zones in Washington Prescriptive Path Single Family 2018 Washington State Energy Code-R 3 Summary of Table R406.2 (cont.) Energy Options Energy Credit Option Descriptions (cont.) Credits - select ONE energy option from each category d User Notes 5.1d Efficient Water Heating 0.5 5.2 Efficient Water Heating 0.5 5.3 Efficient Water Heating 1.0 5.4 Efficient Water Heating 1.5 5.5 Efficient Water Heating 2.0 5.6 Efficient Water Heating 2.5 6.1e Renewable Electric Energy (3 credits max) 1.0 7.1 Appliance Package 0.5 Total Credits a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. b. Equipment listed in Table C403.3.2(4) or C403.3.2(5) d. You cannot select more than one option from any category EXCEPT in category 5. Option 5.1 may be combined with options 5.2 through 5.6. See Table 406.3. c. Equipment listed in Table C403.3.2(1) or C403.3.2(2) e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max. See the complete Table R406.2 for all requirements and option descriptions. Single Family New & Additions (effective February 1, 2021) Please print only pages 1 through 3 of this worksheet for submission to your building official. f. Use the single radiobutton in the upper right of the second column to deselect radiobuttons in that group. Clear FormCalculate Total     !"#$%!() *+,-.1) "!"""/2233 4 5 6#97: "!;<4=>5 =48&1( "!"""?&1 @0 ABCDEBFGHB IG,+FCJA.,&KL&M %!#""!NOP!!*Q!"JR0S&1 JSU &K9&3 &1 #P(X&S >YEBFDEHZF+C[8&2 [33S2 5 @\3 =  9S3 %!*]3^12& ,E_EBF++`CFBDD_EBB EG+CEBA_FbZF.H !`HE_+,E !`HE_]c.HE 4 5 6#**P!6*d"e!ef*g6 $*EkFE`lbE EBA_FbZF.H BBFGHED. Ek !"#$%!Pg" !"EEH.ZE ]"           !"#"$%#& '() '*+,,-./-,0121321114.+-/4567879:;<8=8+,,-./-.0121321114.+-/4E67F@<G