HomeMy WebLinkAbout19010 46th Ave Ne_BLD5176_2024
Permit Packet Coversheet
Community and Economic Development
City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551
Page 1 of 1
Permit Number: Permit Type:
Address/Parcel: Completed (Month/Year):
Land Use
Notice of Decision
Staff Report
Application
Narrative
Legal Description
Vicinity Map
Site Plan
Landscape Plan
Complete Streets Checklist
Traffic Impact Analysis
Snohomish County Traffic Mitigation Offer
WSDOT Traffic Offer Form
Tree Survey
Stormwater Drainage Report
Geotech Report
Critical Area Evaluation Form
SEPA Checklist
Public Notice Material
Noticing and Related Documents
Water / Sewer Availability Certificate
Unanticipated Discovery Plan Form
Aerial Photo of Site
Proposed Building Materials
Lighting Plans and Lighting Cut Sheets
Color Elevations
Design Matrix
Plat Map
Title Report
Lot Closures
Preliminary Civil Plans
Archaeological Survey
o Confidential Documents. Contact the
City to obtain.
Topography (Existing Conditions)
CC&R’s
Deeds / Easements / Conveyances
/Dedications
Developer’s Agreement
Recorded Copies
Bonding or Assignment of Funds
o Confidential Documents. Contact the
City to obtain.
Letters and Project Documents
Other:
Civil
Issued Permit
Application
Other Applications
Construction Calculation Worksheet
Approved Plans
Review Comment Form
Letters and Project Documents
Other Agency Permits
Reports:
o Drainage Report Pg:
o Stormwater Pg:
o Geotech Pg:
o All Other Reports
SEPA and Noticing Materials
Inspections
As-Builts
Other:
Building
Issued Permit
Application
Additional Applications
Approved Plans
Site Plan
Letters and Project Documents
Calculations
Project Specification Manuals
Reports
Certificate of Occupancy
Inspections
Other:
BLD5176 Residential Zoning Verification
19010 46th Ave Ne January 2024
✔
✔
✔
19010 46TH AVE NE , ARLINGTON, WA 98223-4789 35,000
14 00955700001400
CONVERT GARAGE INTO (2) BEDROOMS & STORAGE.
MAMBO THERESE 207 272 5798
19010 46TH AVE NE , ARLINGTON, WA 98223-4789 202 272 5798
WA 98223ARLINGTON19010 46TH AVE NE
HOME OWNER DOING THE WORK
0 0 0 0
7405 2591
2416 33
GEORGE NGANGA 2/21/2023
11776
1776 1776 0 0 640
35,000
0095570000140014
MAMBO THERESE
k.tan76@yahoo.com
207 272 5798
207 272 5798
19010 46TH AVE NE ARLINGTON WA 98223
HOME OWNER DOING THE WORK
CONVERT GARAGE INTO (2) BEDROOMS & STORAGE. REMODEL SF IS 640SF
19010 46TH AVE NE , ARLINGTON, WA 98223-4789
2 $ 50
1 $15
$ 190
GEORGE NGANGA 2/21/2023
INTERIOR WALL FRAMING ELEVATION
SCALE: NONE1
2x4 STUDS 16" O.C.
Header
Sill Plate
Double 2x8 w/
plywood spacer
EXTERIOR WALL FRAMING ELEVATION(4x)
SCALE: NONE
ROUGH
OPENING
Section through window
rough opening
studs 16" O.C.
TYP
KING STUD
BLOCKING
JACK
STUDS
R-10 rigid foam
insulation
2B
1 ST FLOOR
1760 SF
DRIVEWAY
1 SITE PLAN
SCALE: 1"=10'-0"1
N
46TH AVE NE
CNRVT SPACE
640 SF
SIDEWALK SIDEWALK
GRASS VERGEGRASS VERGE
Header
Blocking
Double 2x6 w/
plywood spacer
DOOR FRAMING ELEVATION
SCALE: NONE3
Section through window
rough opening
studs 16" O.C.
TYP
KING STUD
Jack stud
VICINITY PLAN
SCALE: NONE2
Scale
Date
Drawn By
Checked By
Project Number
Varies
CS
-
GM
No.Description Date
A001
SITE & VICINITY
PLANS &
ELEVATIONS
THERESE GARAGE
REMODEL
19010 46TH AVE NE
ARLINGTON, WA 98371
CSLdesigns21@gmail.com
CSL DESIGNS
1/13/2022
LIVING
ROOM
KITCHEN
BEDROOM
A
BEDROOM
B
BEDROOM
C
BEDROOM
D
GARAGE
CLOSET
C
C
CLOSET
C
DECK
BATH
A
BATH
B
DINING
ROOM
SD
SD CO
2
SD
2
SD
SD
SD CO
FRAMING SPECIFICATIONS
FRAMING LUMBER SHALL BE S-DRY, KD, OR WC-19, AND GRADED AND MARKED IN CONFORMANCE WITH WCLIB
STANDARD "GRADING RULES FOR WEST COAST LUMBER NO. 17", OR WWPA STANDARD, "WESTERN LUMBER
GRADING RULES 2011". FURNISH TO THE FOLLOWING MINIMUM STANDARDS:
JOISTS AND BEAMS (2X & 3X MEMBERS) HEM-FIR NO. 2
MINIIMUM BASE VALUE, FB - 850PSI
(4X MEMBERS) DOUGLAS FIR-LARCH NO. 1
MINIIMUM BASE VALUE, FB - 1000PSI
STUDS & MISC. FRAMING DOUGLAS FIR-LARCH OR HEM-FIR NO. 2
PLATES DOUGLAS FIR-LARCH
WOOD FASTENERS
A.NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS:
SIZE LENGTH DIAMETER
8D 2- 1/2" 0.131"
16D 3-1/2" 0.135"
IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT NAIL SPECIFICATIONS TO
THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION ) FOR REVIEW.
NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE DRIVEN FLUSH TO FACE OF
SHEATHING WITH NO COUNTER SINKING PERMITTED. TOE-NAILS SHALL BE DRIVEN AT AN ANGLE OF 30
DEGRESS WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END.
B.ALL BOLTS IN WOOD SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF
ALL BOLTS AND LAG BOLTS SHALL CONFORM TO THE NATIONAL DESIGN SPECIFICATION FOR WOOD
CONSTRUCTION WITH A LEAD BORE HOLE OF 60 TO 70 PERCENT OF THE SHANK DIAMETER. LEAD HOLES ARE
NOT REQUIRED FOR 3/8" AND SMALLER LAG SCREWS.
WOOD FRAMING NOTES--THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS:
A.ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM
STANDARDS OF THE INTERNATIONAL BUILDING CODE, THE AITC "TIMBER CONSTRUCTION MANUAL" AND THE
AF&PA "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION". MINIMUM NAILING UNLESS
OTHERWISE NOTED, SHALL CONFORM TO IRC TABLE R602.3.(1). COORDINATE THE SIZE AND LOCATION OF ALL
OPENINGS WITH ARCHITECTURAL DRAWINGS.
B.WALL FRAMING : REFER TO ARCHITECTURAL DRAWINGS FOR THE SIZE OF ALL WALLS. ALL STUDS SHALL BE
SPACED AT 16" O.C. UNO. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH
SIDE OF ALL OPENINGS, AND AT BEAM OR HEADER BEARING LOCATIONS. TWO 2X8 HEADERS SHALL BE
PROVIDED OVER ALL OPENINGS NOT OTHERWISE NOTED. SOLID BLOCKING FOR WOOD COLUMNS SHALL BE
PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. PROVIDE CONTINUOUS SOLID BLOCKING AT MID-HEIGHT
OF ALL STUD WALLS OVER 10'-0" IN HEIGHT.
ALL WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE TO EACH
STUD WITH 16D NAILS. AND TOENAIL OR END NAIL EACH STUD TO BOTTOM PLATE WITH 16D NAILS. FACE NAIL
DOUBLE TOP PLATE WITH 16D @12" O.C. AND LAP MINIMUM 4'-0" AT JOINTS AND PROVIDE EIGHT 16D NAILS @4"
O.C. EACH SIDE JOINT.
ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH TWO
ROWS OF 16D NAILS @ 12" ON-CENTER, OR ATTACHED TO CONCRETE BELOW WITH 5/8" DIAMETER ANCHOR
BOLTS @ 4'-0" ON-CENTER EMBEDDED 7" MINIMUM, UNLESS INDICATED OTHERWISE. INDIVIDUAL MEMBERS OF
BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH TWO ROWS OF 16D @12" ON-CENTER. UNLESS
OTHERWISE NOTED, GYPSUM WALLBOARD SHALL BE FASTENED TO THE INTERIOR SURFACE OF ALL STUDS
AND PLATES WITH NO. 6 X 1-1/4" TYPE S OR W SCREWS @ 8" ON-CENTER. UNLESS INDICATED OTHERWISE, 1/2"
(NOMINAL) APA RATED SHEATHING (SPAN RATING 24/0) SHALL BE NAILED TO ALL EXTERIOR SURFACES WITH
8D NAILS @ 6" ON-CENTER AT PANEL EDGES AND TOP AND BOTTOM PLATES (BLOCK UN-SUPPORTED EDGES)
AND TO ALL INTERMEDIATE STUDS AND BLOCKING WITH 8D NAILS @ 12" ON-CENTER ALLOW 1/8" SPACING AT
ALL PANEL EDGES AND PANEL ENDS.
BORED OR DRILLED HOLES:
MAY NOT EXCEED 60% OF STUD WIDTH (IF DRILLED OVER 40% MUST
BE DOUBLED)
SHALL NOT BE CLOSER THAN 5/8" TO EDGE OF STUD
SHALL NOT BE IN THE SAME SECTION AS A CUT OR NOTCH
(EXCEPTIONS R602.6; DETAILS: FIGURES R602.6(1),R602.6.2(2),R602.6.1
FIREBLOCKING:
IN CONCEALED SPACES OF STUD WALLS & PARTITIONS AS FOLLOWS:
1.VERTICALLY AT CEILINGS AND WALLS
2.HORIZONTALLY AT MAX. 10' INTERVALS
3.ALL INTERCONNECTIONS SUCH AS SOFFITS, DROP CEILINGS,
COVE CEILINGS.
4.IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT TOP &
BOTTOM OF RUN
5.OPENINGS AROUND VENTS/PIPES/DUCTS AT FLOOR AND
CEILING LEVELS
FIRE BLOCKING MATERIALS SHALL BE CONSISTENT WITH R302.11.1
LOOSE FILL MATERIAL IS NOT ALLOWED
NOTE: ALL FIRE BLOCKS AND DRAFT BLOCKS REQUIRED TO BE
INSTALLED PRIOR TO FRAMING INSPECTION.
DOOR HANDLES:
OPERABLE PARTS OF DOOR HANDLES, PULLS, LATCHES, LOCKS AND
OTHER DEVICES INSTALLED IN ADULT FAMILY HOMES SHALL BE
OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT
GRASPING, PINCHING OR TWISTING OF THE WRIST. POCKET DOORS
SHALL HAVE GRASPABLE HARDWARE AVAILABLE WHEN IN THE
CLOSED OR OPEN POSITION.SCALE: 1/4"=1'-0"1 FLOOR PLAN - EXISTING
SCALE: 1/4"=1'-0"1
N
FUR WH
Scale
Date
Drawn By
Checked By
Project Number
Varies
-
GM
No.Description Date
A002
EXISTING PLANS &
SPECIFICATIONS
CSLdesigns21@gmail.com
CSL DESIGNS
THERESE GARAGE
REMODEL
19010 46TH AVE NE
ARLINGTON, WA 98371
1/13/2022
CS
LIVING
ROOM
KITCHEN
BEDROOM
A
BEDROOM
B
BEDROOM
C
BEDROOM
D
CLOSET
C
C
CLOSET
C
DECK
BATH
A
BATH
B
DINING
ROOM
SD
SD CO
SD
SD
SD
SD CO
SCALE: 1/4"=1'-0"1 FLOOR PLAN - PROPOSED
SCALE: 1/4"=1'-0"1
N
FUR WH
2
SD
CLOSET
BEDROOM
E
182 SF
BEDROOM
F
114 SF
STORAGE
CLOSET
2
SD
SCOPE OF WORK:
CONVERT GARAGE INTO (2) BEDROOMS & STORAGE.1.
CONSTRUCTION NOTES:
INSTALL 5200 BTUH HEAT PUMP. HEAT PUMP SHALL A MINIMUM
EFFICIENCY OF 8.2 HSPF FOR HEATING MODE.
INSTALL NEW SMOKE DETECTORS.
PROVIDE COMBINED FIRE AND SMOKE DETECTOR, C.O.
FUR OUT GARAGE WALLS AS NEEDED TO MAKE ROOM FOR 2x8
STUDS AND INSTALL R-21 +R12 INSULATION.
ROUTE 12" DUCT UP TO ATTIC, TERMINATE WITH GOOSENECK,
PROVIDE HIGH AND LOW OPENING INTO UTILITY ROOM. SEE
SHEET A004 FOR FURNACE COMBUSTION AIR DETAIL.
INSULATE ATTIC TO R-49.
PROVIDE 105 CFM WHOLE HOUSE EXHAUST FAN FV-0511VKL2 OR
EQUAL. CONNECT CONNECT TO 4" EXHAUST DUCT AND ROUTE
ABOVE CEILING TO THE EXTERIOR .TERMINATE WITH A VENT
CAP.PROVIDE R-7 INSULATION FOR DUCTWORK IN ATTIC.
1.
2.
3.
4.
5.
6.
7.
1.
2.
3.
4.
GENERAL NOTES:
ALL SMOKE ALARMS AND COMBINED FIRE AND SMOKE ALARMS ARE
TO BE INTERCONNECTED PER IRC R314.2.2 & R315.2.2
INTERIOR NON-LOAD BEARING WALLS DO NOT REQUIRE
STRUCTURAL HEADER.
PROVIDE INSULATION FOR ALL HOT WATER PIPING WITH A MINIMUM
THERMAL RESISTANCE (R-VALUE) OF R-3.
REFERENCE BORED OR DRILLED HOLES & FIRE BLOCKING
NOTATIONS ON SHEET A002.
1/2" GYPSUM BOARD SEPARATION INSTALLED ON GARAGE SIDE.
STRUCTURAL MEMBERS SUPPORTING HORIZONTAL SEPARATION
REQUIRES ½” GYPSUM BOARD (INCLUDING ALL BEARING WALLS,
POSTS, COLUMNS, ETC..)
FIRE BLOCKING IS REQUIRED FOR ALL OPENINGS AROUND VENTS,
PIPES, DUCTS, CABLES AND WIRES TO RESIST PASSAGE OF FLAMES
AND COMBUSTION.
FRAME WALLS, INSTALL DOORS, WINDOWS PER ELEVATION DETAILS
ON SHEET A001 AND PER FRAMING SPECIFICATIONS ON SHEET A002.
5.
6.
·2018 INTERNATIONAL RESIDENTIAL CODE(IRC),
EDITION & WAC 51-51
·2018 UNIFORM PLUMBING CODE (UPC),EDITION &
WAC 51-56, 51-57
·2018 WASHINGTON STATE ENERGY CODE
RESIDENTIAL (WSEC)
INTERIOR WALL ASSEMBLY DETAIL
1/2" Gypsum
wall board
2x4 STUD @ 16" O.C.
1/2" Gypsum
wall board
1
1
(N) 4'x 4' window w/ (2)2x8
Header, 0.22 U-value, 5.7
SF min opening. Height
from Floor to window net
clear opening shall be a
max of 44".(TYP. 3)
SUMMARY OF TABLE R406.2
OPTION FUEL NORMALIZATION DESCRIPTION CREDIT(S)
1.5 EFFICIENT BUILDING ENVELOPE 1.5: 2.0
Vertical fenestration U=0.22
Wood frame wall R-21 int plus R-12 floor R10
2 HEAT PUMP 1.0
OPTION ENERGY CREDITS DESCRIPTION CREDIT(S)
Garage door to remain
Garage door to remain
5
22x30
ATTIC
ACCESS
7
7.
Scale
Date
Drawn By
Checked By
Project Number
No.Description Date
A003
PROPOSED
PLAN
-
GM
Varies
-
CSLdesigns21@gmail.com
CSL DESIGNS
THERESE GARAGE
REMODEL
19010 46TH AVE NE
ARLINGTON, WA 98371
1/3/2022
CS
Minimum 1"
Insulation baffles
R-49 Insulation
5/8" Gypsum wall board
Double 2x6 Top plate
1/2" Gypsum wall board
R-21 Insulation plus R-12
3/4" T&G Plywood or Equiv
subfloor glued & nailed
Floor Joist
per plan
1
Existing garage door
to remain.
Vented blocking
water resistive
barrier(tyvek)
Existing roof
EXTERIOR WALL FRAMING DETAIL
SCALE: NONE
2x6
Install 3
4" rigid foam
board on the inside of
garage door. Protect
R-21 insulation from
moisture by using spray
foam where there are
gaps.
R-10 Insulation
Concrete curb per
detail #2 on this page
3 SILL PLATE ATTACHMENT DETAIL
SCALE: NONE
Sill plate attached per 2018 IRC
R317,R318,R403.1.6,R602.11.1
FURNACE
DUCT
Ceiling
Floor
12" Duct with high
and low 6" opening
Roof
FURNACE COMBUSTION AIR DETAIL
NOTE: INSTALL DUCTWORK PER 2018 IRC CHAPTER 16
2x6 P.T. plate
Existing driveway
Frame in garage door
opening with 2x6 studs
@16" o.c. with 1/2"
sheathing on the exterior.
Existing header to remain
in the opening.
2
Existing garage floor
CURB DETAIL
SCALE: NONE
2x10 joist
2x10 P.T. Rim joist
4x2 P.T. Sleeper set in mastic to
foundation with simpson "titen"
concrete screw & 3"x3"x1/4" seismic
washer 4' O.C.imbed 3" min.
2x10 JOIST RIP AS NECESSARY
(E)Garage door
New curb. Min 6" wide and
6" high. Max height equal to
height of existing stemwall.
Insulate as required.
1/2" Anchor bolts @6ft o.c. embed 7"
min. into curb. Use screw anchors into
slab where curb is less than 7"
tall.3"x3"x0.225" plate washer
SCALE: 1/4"=1'-0"1 GARAGE FLOOR FRAMING PLAN
SCALE: 1/4"=1'-0"1
FUR WH
6 mil vapor barrier
required on top of slab.
Lap splices 12" min and
6" min up the sides
2x10 Floor
joists attach to
ledger w/ joist
hangers
Joist lumber
species shall
be hem-fir/doug
fir NO. 2
2x10 P.T. Rim joist
(N) curb per detail 2
on sheet A004
For exterior wall
installation refer
detail #1 on sheet
A004
3/4" Plywood
floor sheathing
species group 4
R-10 Rigid Insulation
below sleepers. (TYP.)
4x2 P.T. Mid-span support
that is anchored to the
concrete slab per curb
detail #2 on sheet
A004.(TYP. 3)
2x10 P.T. ledger
board w/ 1
2" x4 lag
screw & washer. See
lag screw placement
detail on sheet A004.
2x10 Blocking every 48"
Max, staggered
Scale
Date
Drawn By
Checked By
Project Number
No.Description Date
A004
DETAILS & GARAGE
FLOOR FRAMING PLAN
-
GM
Varies
-
CSLdesigns21@gmail.com
CSL DESIGNS
THERESE GARAGE
REMODEL
19010 46TH AVE NE
ARLINGTON, WA 98371
1/13/2022
CS
Window, Skylight and Door Schedule
Project Information Contact Information
Width Height
Ref. U-factor Qt. Feet Inch Feet Inch Area UA
Exempt Swinging Door (24 sq. ft. max.)WSEC 0.00 0 0 0 0.0 0.00
0.0 0.00
Vertical Fenestration (Windows and doors)
Component Width Height
Description Ref. U-factor Qt. Feet Inch Feet Inch Area UA
WSEC 0.22 3 4 0 4 0 48.0 10.56
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
Exempt Glazed Fenestration (15 sq. ft. max.)
Therese Remodel CSL Designs
19010 46TH AVE NE 2065486798
ARLINGTON, WA 98371
Windows
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
Sum of Vertical Fenestration Area and UA 48.0 10.56
Vertical Fenestration Area Weighted U = UA/Area 0.22
Overhead Glazing (Skylights)
Component Width Height
Description Ref. U-factor Qt. Feet Inch Feet Inch Area UA
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
Sum of Overhead Glazing Area and UA 0.0 0.00
Overhead Glazing Area Weighted U = UA/Area 0.00
48.0 10.56Total Sum of Fenestration Area and UA (for heating system sizing calculations)
Simple Heating System Size: Washington State
Project Information Contact Information
Heating System Type:
To see detailed instructions for each section, place your cursor on the word "Instructions"
Design Temperature
Instructions Design Temperature Difference (∆T) 47
∆T = Indoor (70 degrees) - Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area (sq ft) 640
Average Ceiling Height Conditioned Volume
Instructions Average Ceiling Height (ft)7.0 4,480
Glazing and Doors U-Factor X Area = UA
Instructions
0.220 48 10.56
Skylights U-Factor X Area = UA
Instructions 0.50 ---
Insulation
Attic U-Factor X Area = UA
Instructions 0.026 640 16.64
Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA
Instructions ---________
Above Grade Walls (see Figure 1)U-Factor X Area UA
Instructions 0.032 462 14.78
Floors U-Factor X Area UA
Instructions --- 0 ________
Below Grade Walls (see Figure 1)U-Factor X Area UA
Instructions No selection ---
Slab Below Grade (see Figure 1)F-Factor X Length UA
Instructions No selection ---
Slab on Grade (see Figure 1)F-Factor X Length UA
Instructions 0.360 66 23.76
Location of Ducts
Instructions Duct Leakage Coefficient
1.10
Sum of UA 65.74
Envelope Heat Load 3,090 Btu / Hour
Sum of UA x ∆T
Air Leakage Heat Load 2,274 Btu / Hour
Volume x 0.6 x ∆T x 0.018
Building Design Heat Load 5,364 Btu / Hour
Air leakage + envelope heat loss
Building and Duct Heat Load 5,900 Btu / Hour
Ducts in unconditioned space: sum of building heat loss x 1.10
Ducts in conditioned space: sum of building heat loss x 1
Maximum Heat Equipment Output 7,376 Btu / Hour
Building and duct heat loss x 1.40 for forced air furnace
Building and duct heat loss x 1.25 for heat pump
This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals
J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads.
Please complete the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section, some
values will be calculated for you. If you do not see the selection you need in the drop-down options, please contact the WSU Energy Program at
energycode@energy.wsu.edu or (360) 956-2042 for assistance.
Therese Remodel
19010 46TH AVE NE
ARLINGTON, WA 98371
CSL Designs
2065486798
Above Grade
Below Grade
Figure 1.
All Other Systems Heat Pump
(07/01/13)
2018 Washington State Energy Code ResidentialPrescriptive Energy Code Compliancefor All Climate Zones in Washington
Prescriptive Path Single Family 2018 Washington State Energy Code-R 1
Project Information Contact Information
Instructions: This single-family project will use the requirements of the Prescriptive Path below and
incorporate the minimum values listed. Based on the size of the structure, the appropriate number of
additional credits are checked as chosen by the permit applicant.
Authorized Representative Date
n/a n/a
a
R-values are minimums.U-factors and SHGC are maximums. When insulation is installed in a cavity that is less
than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix
Table A101.4 shall not be less than the R-value specified in the table.
b The fenestration U-factor column excludes skylights.
c
"10/15/21 +5TB" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on
the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at
the interior of the basement wall. "10/15/21 +5TB" shall be permitted to be met with R-13 cavity insulation on
the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB"
means R-5 thermal break between floor slab and basement wall.
g For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for
climate zone 5 of ICC 400.
h
Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard
framing 16 inches on center, 78% of the wall cavity insulated and headers insulated with a minimum of R-10
insulation.
These requirements apply to all IRC building types, including detached one- and two-family
dwellings and multiple single-family dwellings (townhouses).
Provide all information from the following tables as building permit drawings: Table R402.1 - Insulation and
Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 406.3 - Energy Credits.
All Climate Zones (Table R402.1.1)
R-Value a U-Factor a
Fenestration U-Factor b n/a 0.30
Skylight U-Factor b n/a 0.50
Glazed Fenestration SHGC b,e
d R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1.
e
f
R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter
slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall
meet the requirements for thermal barriers protecting foam plastics.
For single rafter- or joist-vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth
extends over the top plate of the exterior wall.
Ceiling e 49 0.026
Wood Frame Wall g,h 21 int 0.056
Floor 30 0.029
Below Grade Wall c,h 10/15/21 int + TB 0.042
Slab d,f R-Value & Depth 10, 2 ft n/a
Single Family New & Additions (effective February 1, 2021) Version 1.0
02/21/2023
THERESE GARAGE REMODEL
19010 46TH AVE NE , ARLINGTON, WA 98223-4789
CSL DESIGNS
206 548 6798
2018 Washington State Energy Code ResidentialPrescriptive Energy Code Compliance for All Climate Zones in Washington
Prescriptive Path Single Family 2018 Washington State Energy Code-R 2
2.Medium Dwelling Unit: 6 credits
All dwelling units that are not included in #1 or #3
3.Large Dwelling Unit: 7 credits
Dwelling units exceeding 5,000 sf of conditioned floor area
4.Additions less than 500 square feet: 1.5 credits
All other additions shall meet 1-3 above
Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4.
Summary of Table R406.2
Heating
Options Fuel Normalization Descriptions Credits - select ONE
heating option User Notes
4 DHP with zonal electric resistance per option 3.4 0.5
5 All other heating systems -1.0
Energy
Options Energy Credit Option Descriptions
Credits - select ONE
energy option from each
category d
1.3 Efficient Building Envelope 0.5
1.5 Efficient Building Envelope 2.0
1.6 Efficient Building Envelope 3.0
1.7 Efficient Building Envelope 0.5
2.1 Air Leakage Control and Efficient Ventilation 0.5
2.2 Air Leakage Control and Efficient Ventilation 1.0
2.3 Air Leakage Control and Efficient Ventilation 1.5
2.4 Air Leakage Control and Efficient Ventilation 2.0
3.1a High Efficiency HVAC 1.0
3.2 High Efficiency HVAC 1.0
3.3a High Efficiency HVAC 1.5
3.4 High Efficiency HVAC 1.5
3.5 High Efficiency HVAC 1.5
3.6a High Efficiency HVAC 2.0
4.1 High Efficiency HVAC Distribution System 0.5
4.2 High Efficiency HVAC Distribution System 1.0
1.2 Efficient Building Envelope 1.0
1 Combustion heating minimum NAECAb 0.0
1.1 Efficient Building Envelope 0.5
1.4 Efficient Building Envelope 1.0
2 Heat pumpc 1.0
3 Electric resistance heat only - furnace or zonal -1.0
1.Small Dwelling Unit: 3 credits
Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area.
Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf.
Single Family New & Additions (effective February 1, 2021)
Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel
normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of
credits. To claim this credit, the building permit drawings shall specify the option selected and the
maximum tested building air leakage, and show the qualifying ventilation system and its control sequence
of operation.
2018 Washington State Energy Code ResidentialPrescriptive Energy Code Compliance for All Climate Zones in Washington
Prescriptive Path Single Family 2018 Washington State Energy Code-R 3
Summary of Table R406.2 (cont.)
Energy
Options Energy Credit Option Descriptions (cont.)
Credits - select ONE
energy option from
each category d User Notes
5.1d Efficient Water Heating 0.5
5.2 Efficient Water Heating 0.5
5.3 Efficient Water Heating 1.0
5.4 Efficient Water Heating 1.5
5.5 Efficient Water Heating 2.0
5.6 Efficient Water Heating 2.5
6.1e Renewable Electric Energy (3 credits max) 1.0
7.1 Appliance Package 0.5
Total Credits
a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or 500 W,
whichever is bigger, may be installed in the dwelling unit.
b. Equipment listed in Table C403.3.2(4) or C403.3.2(5)
d. You cannot select more than one option from any category EXCEPT in category 5. Option 5.1 may be combined
with options 5.2 through 5.6. See Table 406.3.
c. Equipment listed in Table C403.3.2(1) or C403.3.2(2)
e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max.
See the complete Table R406.2 for all requirements and option descriptions.
Single Family New & Additions (effective February 1, 2021)
Please print only pages 1 through 3 of this worksheet for submission to your building official.
f. Use the single radiobutton in the upper right of the second column to deselect radiobuttons in that group.
Clear FormCalculate Total
!"#$%!() *+,-.1) "!"""/2233 45
6#97: "!;<4=>5=48&1( "!""" ?&1 @0 ABCDEBFGHBIG,+FCJA.,&KL&M %!#""!NOP!!*Q!"JR0S&1 JSU
&K9&3 &1 #P(X&S >YEBFDEHZF+C[8&2 [33S2 5@\3 = 9S3 %!*]3^12& ,E_EBF++`CFBDD_EBB EG+CEBA_FbZF.H !`HE_+,E !`HE_]c.HE 45
6#**P!6*d"e!ef*g6$*EkFE`lbE EBA_FbZF.H BBFGHED. Ek !"#$%!Pg" !"EEH.ZE ]"
!"#"$%#& '()
'*+,,-./-,0121321114.+-/4567879:;<8=8+,,-./-.0121321114.+-/4E67F@<G