HomeMy WebLinkAbout18333 Cedarbough Loop_BLD2333_2025 18333 Cedarbough Loop Arlington, Wa 98223 Replace 80% Nat. Gas Furnace with 95% Nat. Gas Furnace Laura Kuhl 18333 Cedarbough Loop Arlington Wa 98223 360-722-4593 laurabkuhl@aol.com Cozy Heating, Inc. 20221 67th Ave NE Arlington Wa 98223 360-435-4904 smaisch.cozy@gmail.com Cozy Heating, Inc. 20221 67th Ave NE Arlington Wa 98223 CC COZYHI*122MM 12/22/2019 360-435-4904 info@cozyheatinginc.com S9X2B060D3PS 95% ✔ ✔ 01/02/2019 Steven Maisch Submittal Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH Downflow Only S9X2B060D3PSAB Note: Graphics in this document are for representation only. Actual model may differ in appearance. TAG:______________________________ SAFETY WARNING Onlyqualifiedpersonnelshouldinstallandservicetheequipment.Theinstallation,startingup,andservicingofheating,ventilating,and air-conditioningequipmentcanbehazardousandrequiresspecificknowledgeandtraining.Improperlyinstalled,adjustedoraltered equipmentbyanunqualifiedpersoncouldresultindeathorseriousinjury.Whenworkingontheequipment,observeallprecautionsinthe literatureandonthetags,stickers,andlabelsthatareattachedtotheequipment. July 2018 S9X2B060D3-SUB-1B-EN Outline Drawings e c a rn t u e F in w b o a fl C n e w iz o D B S 2 S9X2B060D3-SUB-1B-EN Product Specifications MODEL S9X2B060D3PSAB (a) MODEL S9X2B060D3PSAB (a) TYPE Downflow —Unfired 29–4CStainlessSteel RATINGS(b) Gauge(Fired) 20 1stStageInputBTUH(ICS) 39,000 ORIFICES—Main 1stStageCapacityBTUH 37,830 Nat.GasQty.—DrillSize 3-45 2ndStageInputBTUH 60,000 LPGasQty.—DrillSize 3-56 2ndStageCapacityBTUH(ICS)(c)(d) 58,200 GASVALVE Redundant-TwoStage 1stStageTemp.Rise(Min.-Max.) 25-55 PILOTSAFETYDEVICE 2ndStageTemp.Rise(Min.-Max.) 35-65 Type 120VSiNiIgniter AFUE(%) 95.0 BURNERS—Type MultiportInshot BLOWERDRIVE DIRECT Number 3 Diameter—Width(In.) 11X8 POWERCONN.—V/Ph/Hz(h) 120/1/60 No.Used 1 Ampacity(InAmps) 9.3 Speeds(No.)(e) 5 Max.OvercurrentProtection(Amps) 15 CFMvs.in.w.g. SeeFanPerformance PIPECONN.SIZE(in.) 1/2 Table DIMENSIONS HxWxD MotorHP 1/2 Uncrated(In.) 34x17-1/2x28–3/4 RPM 1075 Crated(In.) 35-1/2x19-1/2x30-7/8 Volts/Ph/Hz 120/1/60 WEIGHT FLA 6.8 Shipping(Lbs.)/Net(Lbs.) 127/119 COMBUSTIONFAN—Type Centrifugal Drive—No.Speeds Direct-2 (a) MeetsEnergyStar (b) ForU.S.applications,aboveinputratings(BTUH)areupto2,000 MotorHP—RPM 3300/2600 feet,derate4%per1,000feetforelevationsabove2,000feetabove sealevel.ForCanadianapplications,aboveinputratings(BTUH)are Volts/Ph/Hz 120/1/60 upto4,500feet,derate4%per1,000feetforelevationsabove4,500 feetabovesealevel. FLA 0.66 (c) CentralFurnaceheatingdesignsarecertifiedtoANSIZ21.47/CSA 2.3. FILTER—Furnished? No (d) BasedonU.S.governmentstandardtests. Typerecommended HighVelocity (e) 5SpeedconstanttorqueECMblowermotor (f) RefertotheVentLengthTableintheInstaller'sGuide. HiVel.(No.-Size-Thk.) 2—14x20—1in. (g) AllS9X2furnacemodelshaveaventoutletdiameterthatequals2in. VENTPIPEDIAMETER—Min(in.) (h) TheabovewiringspecificationsareinaccordancewithNational 2Round (f)(g) ElectricalCode;however,installationsmustcomplywithlocalcodes. HEATEXCHANGER Type—Fired 409StainlessSteel S9X2B060D3-SUB-1B-EN 3 Heating and Cooling Airflow Tables Table 1. Downflow Cooling Table FURNACEAIRFLOW(CFM)VS.STATICPRESSURE(ins.w.g) MODEL SPEEDTAP 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 5-HIGH 1462 1431 1400 1369 1335 1298 1256 1210 1165 4-MED-HIGH 1247 1205 1163 1121 1075 1026 977 927 876 S9X2B060D3PSAB 3-MEDIUM 1094 1047 1000 953 899 844 787 736 685 2-MED-LOW 941 880 819 758 690 629 571 505 443 1-LOW 825 769 704 634 567 499 426 368 316 Table 2. 2nd Stage Heating Table — Downflow CFMVS.2NDSTAGETEMPERATURERISE CFM(CUBICFEETPERMINUTE) MODEL 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 S9X2B060D3PSAB 63 58 52 48 44 41 37 Table 3. 1st Stage Heating Table — Downflow CFMVS.1STSTAGETEMPERATURERISE MODEL CFM(CUBICFEETPERMINUTE) 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 S9X2B060D3PSAB 51 46 42 39 36 32 29 25 4 S9X2B060D3-SUB-1B-EN General Features NATURAL GAS MODELS ENERGY EFFICIENT OPERATION Central Heating furnace designs are certified by the Furnace is certified by the manufacturer to leak 1% or American Gas Association for both natural and L.P. less of nominal air conditioning CFM delivered when gas. Limit setting and rating data were established and pressurized to .5" water column with all inlets, outlets, approved under standard rating conditions using and drains sealed. American National Standards Institute standards. AIR DELIVERY SAFE OPERATION The variable speed blower motor has sufficient airflow The Integrated System Control is a solid state device for most heating and cooling requirements and will which continuously monitors for presence of flame switch from heating to cooling speeds on demand from when the system is in the heating mode of operation. room thermostat. Dual solenoid combination gas valve and regulator SECONDARY HEAT EXCHANGER provide additional safety. The S-Series furnace has a special type 29- 4C™ QUICK HEATING stainless steel secondary heat exchanger to reclaim Durable, cycle tested, heavy gauge tubular stainless heat from flue gases which would normally be lost. steel primary heat exchanger quickly transfers heat STYLING to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and Heavy gauge steel and "wrap-around" cabinet provide a positive discharge of gas fumes to the construction is used in the cabinet with baked-on outside. enamel finish for strength and beauty. Every orientation has at least two venting options. There are BURNERS no knockouts on cabinet. Multiport Inshot burners will give years of quiet and FEATURES AND GENERAL OPERATION efficient service. All models can be converted to L.P. gas with LP conversion kit. The S-Series furnace utilizes a Silicon Nitride Hot Surface Ignition system, which eliminates the waste of INTEGRATED SYSTEM CONTROL a constant burning pilot. The integrated system control Exclusively designed operational program provides lights the main burners upon a demand for heat from total control of furnace limit sensors, blowers, gas the room thermostat. Complete front service access. valve, flame control and includes self diagnostics for a. Low energy power venter ease of service. Also contains dry contacts for EAC and HUM. b. Vent proving pressure switches. S9X2B060D3-SUB-1B-EN 5 Features and Benefits UP TO 96.0% AFUE ON S9X2 FURNACE MODELS Last six errors stored Meets utility rebates Dry contact EAC and HUM connections Lowers utility bills All Molex connections; no spade terminals ELECTRICALLY EFFICIENT Low voltage labeled above and below Efficient airflow design reduces electrical energy use Rain shield over IFC keeps condensate off the control 34 INCH TALL TUBULAR STAINLESS STEEL PRIMARY HEAT EXCHANGER Lighter, easier to move and fit into tight spaces like 29–4C STAINLESS STEEL SECONDARY HEAT short basements or tight closets EXCHANGER Works great with larger, high-efficiency coils Stainless steel is a more durable, corrosive-resistant No knockouts material than aluminumized steel 3–WAY MULTI-POISE / DEDICATED DOWNFLOW Integrated rail system for easy access if required 11 SKU’s — Upflow / Horizontal Left / Horizontal Right Reduces or eliminates need for baffles 5 SKU’s — Downflow VORTICA II BLOWER, DESIGNED EXCLUSIVELY Added application flexibility and reduction in FOR THE S-SERIES FURNACE specification errors Improved airflow efficiency AIRFLOW Durable, easy to clean, two piece housing At least 400 CFM/ton at 0.5 in. H20 external static Single piece belly band/ motor arm assembly pressure; setup airflow options down to 290 CFM/ton Blower deck has full-length rails for easy removal and REGULATORY replacement, regardless of poise All models are air tight; 1% or less air leakage as per THREE–WAY MULTI-POISE (UPFLOW, ASHRAE 193 HORIZONTAL LEFT AND RIGHT) PLUS DEDICATED Open vestibule design provides a full 34” high open DOWNFLOW vestibule Easier to specify DIMENSIONS Shipped ready to install (no conversion kits required) Widths are industry standard: 17.5”, 21”, and 24.5” Every model has at least two venting options Depth remains approximately 28” When in horizontal, trap extends only about 2” Cabinet will be compatible with industry standard coils, Barbed fitting on trap at hose connection and on as well as, other accessories cabinet transition for hose has barbed fitting and INTEGRATED FURNACE CONTROL clamps at both ends for leak resistance. Setup / Status / Diagnostics / Digital Display Vent table improvements including longer vent lengths; 2” pipe can be used up to 100K No dip switches 6 S9X2B060D3-SUB-1B-EN Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Car®, Ingersoll Rand®, Thermo King® and Trane®—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. ingersollrand.com IngersollRandhasapolicyofcontinuousproductandproductdataimprovementsandreservestherighttochangedesignandspecifications withoutnotice. Wearecommittedtousingenvironmentallyconsciousprintpractices. S9X2B060D3-SUB-1B-EN 12Jul2018 SupersedesS9X2B060D3-SUB-1A-EN (April2017) ©2016IngersollRand Permit #: 2333 Permit Date: 01/02/19 Permit Type: RESIDENTIAL MECHANICAL Project Name: Kuhl Applicant Name: Cozy Heating, Inc. Applicant Address: 20221 67th Avenue NE Applicant, City, State, Zip: Arlington, WA 98223 Contact: Steven Maisch Phone: 360-435-4904 Email: info@cozyheatinginc.com Scope of Work: Replace Gas Furnace Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 01/03/2019 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Property Parcel # Address Legal Description Owner Name Owner Phone Zoning 18333 CEDARBOUGH KUHL DAVID & 111 Single Family 00738500405500 LOOP LAURA Residence - Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License # 20221 67TH AVE CONSTRUCTION COZY HEATING Vince Willett 360-435-4904 City of Arlington 601 088 561 NE CONTRACTOR 20221 67TH AVE CONSTRUCTION LABOR & COZY HEATING Vince Willett 360-435-4904 COZYHI*122MM NE CONTRACTOR INDUSTRIES Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status R00. FURNACE 01/15/2019 Gas furnace approved 01/15/2019 BUILDING Approved FINAL Fees Fee Description Notes Amount Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Total $75.00 Attached Letters Date Letter Description 01/02/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 01/02/2019 Vince Willett 73288780 cc $75.00 Outstanding Balance $0.00 Notes Date Note Created By: 01/02/2019 Emailed permit for signature. Kristin Foster Uploaded Files Date File Name 02/01/2019 4468400-2333_1-15-19 Inspection card.pdf 01/03/2019 4369679-2333_Issued Permit.pdf 01/02/2019 4367506-2333_Specs.pdf 01/02/2019 4367507-2333_Application.pdf 01/02/2019 4367502-2333_Application.pdf