Loading...
HomeMy WebLinkAbout17626 Redhawk Dr_BLD2882_2026 M1 CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 --= ` PHONE; (360)403-3551 BUILDING PERMIT Address:17626 Redhawk Dr Permit#:2882 Parcel#:00809200004600 Valuation: 00 OWNER APPLICANT CONTRACTOR Name:NYLAND ERIC A&PAMELA J Name:[Company Name] Name:CM Heating Inc Address: 17626 REDHAWK DR Address:[Company Address] Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 LIC: EXP: MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address: 1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone-425-259-0550 Phone: LIC#:CMHEAMH877DN EXP: 03/15/2021 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASH INGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRCI 10. SALES T1X NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on%•our sales tax return form and coded CaN o',Arlington 93101 I7 KAILANA MONIZ 11/04/19 rraa; 11/4119 Slgnuluie Print Name Date lirlcas 1% Date CONDITIONS Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/04/2019 Furnace $25.00 11/04/2019 Mechanical Pen-nit Base Fee $25.00 11/04/2019 Process ing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0 00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon I RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES, PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:17626 REDHAWK DR Project Description:LIKE IN KIND GAS FURNACE CHANGE OUT Owner: ERIC NYLAND Address: 17626 REDHAWK DR City:ARLINGTON StateWA Zip Code: 98223 Phone: 206-501-1433 Email:eric.nyland@comcast.net Applicant: KAILANA MONIZ Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 Phone: 425-259-0550 Email: KAILANA@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:CM HEATING Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration: 05/03/21 Phone:425-259-0550 Email:KAILANA@CMHEATING.COM STAFF USE ONLY Permit#: Z Accepted by: Date: 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model ##S8B1B060M3PSAA AFUE80 ❑ Heat Pump Model # AFUE HSPE Ali AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping D Solid-Fuel Appliance Ll Other Gas Piping Information Not Applicable: LJ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date: 11/01/2019 Applicant Printed Name: KAILANA MONIZ I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 Submittal Upflow / Downflow / Horizontal Left/Right Single Stage Non-condensing Gas Fired Furnace 60,000 BTU H S8B1 B060M3PSAA s u Note:Models may have a"T"in the 12th digit designating they meet California less than 40 ng/J(NOx)emissions requirements. Note:Graphics in this document are for representation only.Actual model may differ in appearance. TAG: I SAFETY WARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. February2019 S8B1 B060M3-SUB-1A-EN OR7/ngersollRand .� I I I I Outline Drawings Table 1. 17.5"Width Cabinet i ? a a s a _ _ E g ^ 4 _ ° K W N 1 11 It ; ®JM fft�il t :—Tj m J a -I R IVIi ?1iw• 3 2 S8B 1 BO60M3-SUB-1 A-EN i Product Specifications MODEL S89180601M13PSAA MODEL S8B1B060M3PSAA TYPE Upflow/Horizontal/ HEAT EXCHANGER Downflow RATINGS(a) Type Aluminized Steel Input BTUH 60,000 Gauge(Fired) 20 Capacity BTUH(ICS)(b) 48,000 ORIFICES—Main Temp.Rise(Min.-Max.) 30-60 Nat.Gas Qty.—Drill Size 3-45 AFUE(%) 80 GAS VALVE Redundant-Single Stage BLOWER DRIVE DIRECT PILOT SAFETY DEVICE Diameter—Width(In.) 11 X 8 Type 120 V SiNi Igniter No.Used 1 BURNERS—QTY 3 Speeds(No.) 9 POWER CONN.—V/Ph/Hz(e) 120/1/60 CFM vs.in.w.g. See Fan Performance Ampacity(Amps) 10.1 Table Motor HP 1/2 Max.Overcurrent Protection(Amps) 15 RPM 1075 PIPE CONN.SIZE(in.) 1/2 Volts/Ph/Hz 120/1/60 DIMENSIONS FLA 6.8 Uncrated(In.) 34 x 17.5 x 28.75 COMBUSTION FAN—Type Centrifugal Crated(In.) 35.5 x 19.5 x 30.87 Drive—No.Speeds Direct-1 WEIGHT Shipping(Lb..)/Net(Lbs.) 130/122 Motor HP—RPM 3300 (a) For U.S.applications,above input ratings(BTUH)are up to 2,000 Volts/Ph/Hz 120/1/60 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level. FLA 1.39 (b) Central Furnace heating designs are certified to ANSI Z21.47/CSA FILTER—Furnished? No 2.3—latest edition. W Based on U.S.government standard tests. Type recommended High Velocity (d) Refer to the Installer's Guide. M The above wiring specifications are in accordance with National High Val.(No:Size Thk.) 1—16x25—1 in. Electrical Code;however,installations must comply with local codes. VENT PIPE DIAMETER—Min(in.)(d) 4 Round S8B1 B060M3-SUB-1A-EN 3 Airflow tables Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 629 67 — — — 2 987 795 603 411 219 3 1184 1042 901 759 618 4 1244 1109 973 837 701 S8BlB06OM3PSAA 5 1366 1244 1123 1001 880 6 1398 1283 1168 1053 938 7 1479 1374 1270 1165 1061 8 1547 1447 1348 1248 1148 9 1634 1541 1449 1357 1264 4 S8B1 B06OM3-SUB-IA-EN i General Features NATURAL GAS MODELS valve,flame control and includes self diagnostics for Central Heating furnace designs are certified by Intertek ease of service. for both natural and L.P.gas.Limit setting and rating ENERGY EFFICIENT OPERATION data were established and approved under standard Air-TiteTM cabinet design is certified to<1%air leakage rating conditions using American National Standards per ASHRAE 193"Method of Test for Determining the Institute standards. Airtightness of HVAC Equipment." SAFE OPERATION AIR DELIVERY The Integrated System Control is a solid state device The 9 speed constant torque blower motor has which continuously monitors for presence of flame sufficient airflow for most heating and cooling when the system is in the heating mode of operation. requirements and will switch from heating to cooling Dual solenoid combination gas valve and regulator speeds on demand from room thermostat. provide additional safety. QUICK HEATING STYLING cycle tested,heavy Heavy gauge steel and"wrap-around"cabinet Durable,c y vy gauge tubular aluminized construction is used in the cabinet with baked-on steel heat exchanger quickly transfers heat to provide enamel finish for strength and beauty.Every warm conditioned air to the structure.Low energy orientation has at least two venting options.There are power vent blower,to increase efficiency and provide no knockouts on cabinet. a discharge of gas fumes to the outside. BURNERS FEATURES AND GENERAL OPERATION Multi port,Inshot burners will The S-Series furnace utilizes a Silicon Nitride Hot p give years rtquiet and Surface Ignition system,which eliminates the waste of efficient service.All models can be converted to L.P. a constant burning pilot.The integrated system control gas with LP conversion kit. lights the main burners upon a demand for heat from INTEGRATED SYSTEM CONTROL the room thermostat.Complete front service access. Exclusively designed operational program provides a.Low energy power venter total control of furnace limit sensors,blowers,gas b.Vent proving pressure switches. S8B16060M3-SUB-IA-EN 5 Features and Benefits 80%AFUE on S8B1 FURNACE MODELS Depth remains approximately 28" Lowers utility bills Cabinet is compatible with industry standard coils,as ELECTRICALLY EFFICIENT well as,other accessories Efficient airflow design reduces electrical energy use INTEGRATED FURNACE CONTROL 34INCH TALL Setup/Status/Diagnostics/Digital Display Lighter,easier to move and fit into tight spaces like No dip switches short basements or tight closets Last six errors stored Works great with larger,high-efficiency coils Dry contact EAC and HUM connections No knockouts All Molex connections;no spade terminals 4—WAY MULTI-POISE Low voltage labeled above and below 9 SKU's— Upflow/Downflow/Horizontal Left/ Rain shield over IFC keeps condensate off the control Horizontal Right TUBULAR ALUMINIZED STEEL HEAT EXCHANGER Added application flexibility and reduction in VORTICA II BLOWER,DESIGNED EXCLUSIVELY specification errors FOR THE S-SERIES FURNACE AIRFLOW Improved airflow efficiency At least 400 CFM/ton at 0.5 in.H2O external static Durable,easy to clean,housing pressure REGULATORY Single piece belly band/motor arm assembly All models are air tight;1%or less air leakage as per Blower deck has full-length rails for easy removal and ASHRAE 193 replacement,regardless of poise Open vestibule design provides a full 34" high open FOUR—WAY MULTI-POISE(UPFLOW,DOWNFLOW,HORIZONTAL LEFT AND RIGHT) vestibule for ease of installation and service DIMENSIONS Easier to specify Widths are industry standard:14.5",17.5",21",and Shipped ready to install(no conversion kits required) 24.5" Every model has at least two venting options 6 S8B 1 B060M3-SUB-1 A-EN (fFMR�Ingersoil Rand. Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Car®, Ingersoll Rand®,Thermo King(D and Trane@—work together to enhance the quality and comfort of air in homes and buildings;transport and protect food and perishables;and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progress and enduring results. 0Oingersoll Rand , THERMO KING TAWE' ingersollrand.com Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. S8B1B060M3-SUB-1A-EN 15Feb2019 Supersedes(New) 92019Ingersoll Rand i WaskngMn SUIe D<pa,lmml al Labor&Industries(CDs://Ini.wa.gov). Contractors C M HEATING INC Owner or tradesperson 1415 BROADWAY ...................................... .. ....... Principals EVERETT,WA 98201 Garner,James N,PRESIDENT 425-259-6666 SNOHOMISH County ■ Umayam,John A,VICE PRESIDENT Umayam,Antonio(Tony)G,SECRETARY Umayam,Antonio(Tony)G,TREASURER Garner,James N,AGENT Garner,Paul,PRESIDENT (End:06/29/2016) Garner,Kathleen D,SECRETARY (End:06/29/2016) Garner,Kathleen D,TREASURER (End:06/29/2016) Doing business as C M HEATING INC WA UBI No. Business type 601 114 652 Corporation Governing persons JAMES GARNER PAUL M GARNER; KATHLEEN GARNER; Ficense77 Verify the contractor's active registration I license/certification(depending on trade)and any past violations. Electrical Contractor Active Meets current requirements. License specialties GENERAL License no. CMHEAMH877DN Effective—expiration 03/15/2013—03/15/2021 Designated administrator Active Giacomi,John Meets current requirements. License type License no, Electrical Administrator GIACOJ'840MG Bond Contractors Bonding&Insurance Co $4,000-00 Bond account no SC6810 Received by L&I Effective date 03/15/2013 02/28/2000 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations . � � . . 1 u �f No license violations during the previous 6 y- period. Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent Not allowed to have apprentices. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 490,794-01 Doing business as CHIMNEY MASTERS Estimated workers reported Quarter 3 of Year 2019"51 to 75 Workers" L&I account contact T3/NICHOLE CAROW(360)902-5634-Email:CANI235@lni.wa.gov Public Works Requirements Verify the contractor is eligible to perform work on public works projects. Required Training—Effective July 1,2019 Needs to complete training. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for Inspection results date 0 3/1 612 01 5 No violations Inspection no. 317935327 Location 1415 Broadway Everett,WA 98201 ��Sy � � ., I, I� a � �I w a z C Q c WA Ln z o F. wO a Z n Z o WA M A V - aoa°". Lx�LM � ZZ � . O q Ln V) a Oow Lo mo d W F � Cx04 w Fz M o � U _ L O o 0 o a z a. � vziz d F" F Q O cn O O .. d 4a. U OFF w zaz z .a Qa a a spa O Z owCQ ,W O Ji Ow. FrwL vvFip" OA 4 o 0-4 F" z d ¢ w oFx zao`�. o axa c a. A Woo �, z � cam Ou ¢ 3 � a ❑ ❑ a o F" ❑ ❑ ❑ ❑ ❑ ❑ �� RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 17626 REDHAWK DR Project Description:LIKE IN KIND GAS FURNACE CHANGE OUT Owner: ERIC NYLAND Address. 17626 REDHAWK DR City. ARLINGTON State.WA Zip Code: 98223 Phone. 206-501-1433 Email:eric.nyland@comcast.net Applicant: KAILANA MONIZ Address: 1415 BROADWAY City. EVERETT State.WA Zip Code: 98201 Phone. 425-259-0550 Email: KAILANA@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:CM HEATING Address: 1415 BROADWAY City. EVERETT State.WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration: 05/03/21 P hone: 425-259-0550 Email:KAILANA@CMH EATING.COM STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #S8B1B060M3PSAA AFUE80 ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: [El Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: d5a513be"a92O�tlb81'b61e6' Date: 11/01/2019 Applicant Printed Name: KAILANA MONIZ I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:17626 Redhawk Dr Permit#:2882 Parcel#:00809200004600 Valuation:.00 OWNE APPLICANT CONTRACTOR Name:NYLAND ERIC A&PAMELA J Name:[Company Name] Name:CM Heating Inc Address: 17626 REDHAWK DR Address:[Company Address] Address: 1415 Broadway City,State Zip:ARLINGTON,WA 98223 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 LIC: EXP: MECHANICAL CONTRACTOR PLUMBING CONTRACTORA Name:CM Heating Inc Name: Address: 1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC#:CMHEAMH877DN EXP: 03/15/2021 LIC#: EXP: JOB DESCRIPTION I g PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. rtQw, 11/4/19 Signature Print Name Date Releas9oy Date CONDITIONS Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/04/2019 Furnace $25.00 11/04/2019 Mechanical Permit Base Fee $25.00 11/04/2019 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Submittal Upflow / Downf low / Horizontal Left/Right Single Stage Non-condensing Gas Fired Furnace 60,000 BTU H S8B1 B060M3PSAA 0 s e s /i i Note:Models may have a"T"in the 12th digit designating they meet California less than 40 ng/J(NOx)emissions requirements. Note:Graphics in this document are for representation only.Actual model may differ in appearance. TAG: ASAFETYWARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. February2019 S8B1 B060M3-SUB-1A-EN I( Ingersoll Rand Outline Drawings Table 1. 17.5"Width Cabinet L�7 eY II 90�99 0 W N a000000000000000uuouuuu00000000aa m oaooaououuoouuuoouuuou00000000aaa 8 Mi - xa + T QQ��Q i I a v 2 S8B1 B060M3-SUB-1A-EN Product Specifications MODEL S8B1B060M3PSAA MODEL S8B1B060M3PSAA TYPE Upflow/Horizontal/ HEAT EXCHANGER Downflow RATINGS(a) Type Aluminized Steel Input BTUH 60,000 Gauge(Fired) 20 Capacity BTUH(ICS)(b)(c) 48,000 ORIFICES—Main Temp.Rise(Min.-Max.) 30-60 Nat.Gas Qty.—Drill Size 3-45 AFUE(%) 80 GAS VALVE Redundant-Single Stage BLOWER DRIVE DIRECT PILOT SAFETY DEVICE Diameter—Width(In.) 11 X 8 Type 120 V SiNi Igniter No.Used 1 BURNERS—QTY 3 Speeds(No.) 9 POWER CONN.—V/Ph/HZ(e) 120/1/60 CFM vs.in.w.g. See Fan Performance Ampacity(Amps) 10.1 Table Motor HP 1/2 Max.Overcurrent Protection(Amps) 15 RPM 1075 PIPE CONN.SIZE(in.) 1/2 Volts/Ph/Hz 120/1/60 DIMENSIONS FLA 6.8 Uncrated(In.) 34 x 17.5 x 28.75 C COMBUSTION FAN—Type Centrifugal rated(In.) 35.5 x 19.5 x 30.87 Drive—No.Speeds Direct-1 WEIGHT Motor HP—RPM 3300 Shipping(Lbs.)/Net(Lbs.) 130 (a) For U.S.applications,above input ratings(BTUH)are up to 2,000 Volts/Ph/Hz 120/1/60 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level. FLA 1.39 (b) Central Furnace heating designs are certified to ANSI Z21.47/CSA FILTER—Furnished? No 2.3—latest edition. W Based on U.S.government standard tests. Type recommended High Velocity (d) Refer to the Installer's Guide. e) The above wiring specifications are in accordance with National High Vel.(No.-Size-Thk.) 1—16x25—1 in. Electrical Code;however,installations must comply with local codes. VENT PIPE DIAMETER—Min(in.) 4 Round (d) S8131B060M3-SUB-1A-EN 3 Airflow tables Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 629 67 — 2 987 795 603 411 219 3 1184 1042 901 759 618 4 1244 1109 973 837 701 S8B1B060M3PSAA 5 1366 1244 1123 1001 880 6 1398 1283 1168 1053 938 7 1479 1374 1270 1165 1061 8 1547 1447 1348 1248 1148 9 1634 1541 1449 1357 1264 4 S8B1 B060M3-SUB-lA-EN General Features NATURAL GAS MODELS valve,flame control and includes self diagnostics for Central Heating furnace designs are certified by Intertek ease of service. for both natural and L.P.gas. Limit setting and rating ENERGY EFFICIENT OPERATION data were established and approved under standard Air-TiteTI cabinet design is certified to<1%air leakage rating conditions using American National Standards per ASHRAE 193 "Method of Test for Determining the Institute standards. Airtightness of HVAC Equipment." SAFE OPERATION AIR DELIVERY The Integrated System Control is a solid state device The 9 speed constant torque blower motor has which continuously monitors for presence of flame sufficient airflow for most heating and cooling when the system is in the heating mode of operation. requirements and will switch from heating to cooling Dual solenoid combination gas valve and regulator speeds on demand from room thermostat. provide additional safety. STYLING QUICK HEATING Heavy gauge steel and "wrap-around"cabinet Durable,cycle tested, heavy gauge tubular aluminized construction is used in the cabinet with baked-on steel heat exchanger quickly transfers heat to provide enamel finish for strength and beauty. Every warm conditioned air to the structure. Low energy orientation has least two venting options.There are power vent blower,to increase efficiency and provide no knockouts on cabinet. a discharge of gas fumes to the outside. FEATURES AND GENERAL OPERATION BURNERS The S-Series furnace utilizes a Silicon Nitride Hot Multiport,Inshot burners will give years of quiet and Surface Ignition system,which eliminates the waste of efficient service.All models can be converted to L.P. a constant burning pilot.The integrated system control gas with LP conversion kit. lights the main burners upon a demand for heat from INTEGRATED SYSTEM CONTROL the room thermostat.Complete front service access. Exclusively designed operational program provides a. Low energy power venter total control of furnace limit sensors,blowers,gas b.Vent proving pressure switches. S8B1B0601V13-SUB-1A-EN 5 Features and Benefits 80%AFUE on S8131 FURNACE MODELS Depth remains approximately 28" Lowers utility bills Cabinet is compatible with industry standard coils,as ELECTRICALLY EFFICIENT well as,other accessories Efficient airflow design reduces electrical energy use INTEGRATED FURNACE CONTROL 34 INCH TALL Setup/Status/Diagnostics/Digital Display Lighter,easier to move and fit into tight spaces like No dip switches short basements or tight closets Last six errors stored Works great with larger,high-efficiency coils Dry contact EAC and HUM connections No knockouts All Molex connections; no spade terminals 4—WAY MULTI-POISE Low voltage labeled above and below 9 SKU's — Upflow/Downflow/Horizontal Left/ Rain shield over IFC keeps condensate off the control Horizontal Right TUBULAR ALUMINIZED STEEL HEAT EXCHANGER Added application flexibility and reduction in VORTICA II BLOWER,DESIGNED EXCLUSIVELY specification errors FOR THE S-SERIES FURNACE AIRFLOW Improved airflow efficiency At least 400 CFM/ton at 0.5 in. H2O external static Durable,easy to clean,housing pressure REGULATORY Single piece belly band/motor arm assembly All models are airtight; 1%or less air leakage as per Blower deck has full-length rails for easy removal and ASHRAE 193 replacement,regardless of poise FOUR—WAY MULTI-POISE(UPFLOW,DOWNFLOW, Open vestibule design provides a full 34" high open HORIZONTAL LEFT AND RIGHT) vestibule for ease of installation and service DIMENSIONS Easier to specify Widths are industry standard: 14.5", 17.5",21",and Shipped ready to install(no conversion kits required) 24.5" Every model has at least two venting options 6 S8131 B060M3-SUB-1A-EN (Vumv)lngersoll Rand.; Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club CaO, Ingersoll RandO, Thermo Kingo and Tranel&—work together to enhance the quality and comfort of air in homes and buildings;transport and protect food and perishables;and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progre ss and enduring results. �® Rand T THERMO KING ASrAWE® ingersollrand.com Ingersoll Rand has a policy of continuous product and product data improvements and reserves the rightto change design and specifications without notice. We are committed to using environmentally conscious print practices. S8B1B060M3-SUB-1A-EN 15Feb2019 Supersedes(New) ©2019Ingersoll Rand Permit#: 2882 Permit Date: 11/04/19 Permit Type: RESIDENTIAL MECHANICAL Project Name: Nyland Applicant Name: CM Heating Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett,WA 98201 Contact: Kailana Moniz Phone: 425-259-0550 Email: kailana@cmheating.com Scope of Work: Like in kind gas furnace change out Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 11/04/2019 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00809200004600 17626 REDHAWK DR NYLAND ERIC A& 111 Single Family PAMELA J Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Plumbing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751 W ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION UBI 605890285 ST STE 200 CONTRACTOR Fees Fee Description Notes Amount Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Credit Card Service $2.25 Total $77.25 Attached Letters Date Letter Description 11/04/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 11/04/2019 james garner 77773720 $75.00 11/04/2019 77773720 CC Surcharge Raelynn Jones $2.25 Outstanding Balance $0.00 Uploaded Files Date File Name O1/02/2020 6047364-2882 11-15-19IC.pdf 11/04/2019 5845389-2882 Application(1).pdf 11/04/2019 5845390-2882 Specs.pdf