Loading...
HomeMy WebLinkAbout16415 Smokey Point Blvd._BLD3302_2026 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 _�- INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 - BUILDING PERMIT 16415 Smokey Point Blvd Permit#:3302 Permit Expiration Date: 01/06/2021 Parcel#: 31052800201500 Valuation: 19250.00 APPLICANT CONTRACTOR RGB LLC B&H Fire and Security LLC B&H Fire and Security,LLC 220 146TH PLACE SE PO Box 3711 PO Box 3711 MILL CREEK,WA 98012 Arlington,WA 98223 Arlington,WA 98223 425-244-1445 425-244-1445 LIC:BHFIRHF842KW EXP:05/16/2022 MECHANICAL CONTRACTOR PLUMBING CONTR CTOR LIC#: EXP: LIC#: EXP: .L JOB DESCRIPTIO PERMIT TYPE: Fire Alarm CODE YEAR: 2015 STORIES: 1 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: I OCC LOAD: NEWERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRCI 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date ` Released By `� Date CONDITIONS. t 1. Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request.2.Battery load test required, switch FACP and Power Modules(and communicator/dialer if provided with a battery back- up)to battery operation 24-hours p :o final inspection.Notification appliances to_ :ate for 5 minutes on battery power.3. `Trouble condition to be verified for initiation,notification and signaling circuits.4. Smoke detectors installed in corridors 129 and 150 shall not exceed 30 foot spacing. 5. Strobe coverage in rooms 121, 122 and135 are too far off of wall as indicated on plans. Ensure that proper spacing is observed per cd rating of devices per NFPA 72.6.Manual pull stations shall be dual action. 7. Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). 8.Record of completion form shall be submitted prior to project close-out. 9.Adhere to approved plans. 10.Approved job copy shall be onsite for installation and inspections. 11.Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. - - PERMMIT FEES Date Description Fee Amount 09/21/2020 Fire Alarm System Permit $475.00 09/21/2020 Processing/Technology Fee $25.00 09/21/2020 Fire System Plan Review $312.71 09/21/2020 FACP/Transmitter $200.00 Total Due: $1,012.71 Total Payment: $0.00 Balance Due: $1,012.71 _ - - - - c #ft V - Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon of • • rr Fire Department �L1NG July 14, 2020 Permit Number: BLD 3302 Project Address: 164XX Smokey Point Blvd, Arlington Project Description: Fire alarm for Smokey Point Recovery Center Contractor: Jeff Brossard B&H Fire P.O. Box 3711 Arlington, WA 98223 Re: Fire Alarm Shop Drawing Review Comments/Approval The Arlington Fire Department has completed a review of the Fire Alarm shop drawing submittal and approves the issuance of the permit with the following conditions: 1. Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request. 2. Battery load test required, switch FACP and Power Modules (and communicator/dialer if provided with a battery back- up) to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for initiation, notification and signaling circuits. 4. Smoke detectors installed in corridors 129 and 150 shall not exceed 30 foot spacing. 5. Strobe coverage in rooms 121, 122 and135 are too far off of wall as indicated on plans. Ensure that proper spacing is observed per cd rating of devices per NFPA 72. 6. Manual pull stations shall be dual action. 7. Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection (NFPA 72 Section 7.5.2). 8. Record of completion form shall be submitted prior to project close-out. Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the system at project completion. Final approval will not be provided until all conditions are verified. Call at least 48 hours in advance to schedule an inspection. If there are any questions please do not hesitate to call. Sincerely, Uez Mike Makela OFFICE 0 PY Assistant Fire Chief Arlington Fire Department . CE COPY No active Washington registered apprentices •t for this business.Washington allows the use of apprenu registered with Oregon or Montana.Contact ;regon Bureau of Labor&Industries or Montana Departm f Labor &Industry to venfy if this business has apprentices. Workers' Comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. This company has multiple workers'comp accounts. Active accounts L&I Account ID Account is in good standing. 138,526-01 Quarterly report received and is being _.__...._.. processed. Doing business as B&H FIRE&SECURITY LLC Estimated workers reported N/A L&I account contact T2/DALE RILITTA(360)9024834-Email:RIUD235@Ini.wa.gov Track this contractor 8 Public Works Requirements Verify the contractor is eligible to perform work on public works projects. Required Training—Effective July 1,2019 Exempt from this requirement ...........*....`......... ........ Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace Safety & Health Check for any past safety and health violations found on jobsites this business was responsible for. No inspections during the previous 6 year period. • 05D Permit#: 3302 Permit Date: 07/10/20 Project Name: Smokey Point Recovery Center Site Address: 164XX Smokey Point Blvd Company/Applicant Name: B&H Fire and Security LLC Company/Applicant Address: PO Box 3711 City, State, Zip: Arlington, WA 98223 Contact: Jeff Brossard I Phone: 425-244-1445 Email:jeff@bnhfire.com i Permit Type: Fire Alarm ` ~''% Valuation: 19250.00 Square Feet: 0 'j ", 'r i '. . Number of Stories: 0 Type of Construction: Occupancy Type: Scope of Work: New Fire Alarm MIC/Opportunity Zone: Permit Issued: Permit Expires: 01/06/2021 DNU: Status: IN PROCESS Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31052800201500 UNKNOWN UNKNOWN RGB LLC 910 Undeveloped (Vacant) Land Contractors Contractor Primary Contact Phone Address Contractor Type License License# B&H Fire and Jeff Brossard 425-244-1445 PO Box 3711 CONTRACTOR Labor and BHFIRHF842KW Securitv.LLC Industries Plan Reviews Date Review Type Description Assigned To Review Status 07 10/2020 Fire Alarm Building In Review 07 10/2020 Fire Alarm Fire In Review '' FIRE ALARNN PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •WA 98223 • Phone (360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO,INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS, (POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) 'E New Fire Alarm ❑ Fire Alarm Alteration/Addition Project Address l o=< 4 FlvwT Parcel ID#: Number of Zones/Panels: j Building Area(Sq Ft): IH S-F Valuation: A.?-To s� Owner: GiZAwlW1tZv3 XbM Lld. Phone Number: 360 435' "712I Address: P0 &17, 1S q City: State: t14A Zip Code: 9cezzs Contact Person: ?-'�rvzo Phone Number: 42A 74LI W4 S' Cell Phone: Email: =G>� atq NFIR.t. Address: �O �x 3"7 1 City: JVZtr1N4.1 vfs) State: WA Zip Code: libs-?_� Contractor: $ R f11Lt AND 5Cc>a2rf`1 L.LC., Phone Number: q?-< 7-H14 I`fN 5� Address: Pn Boy, 3711 City: ANLLINo.Tori State: I' 'CS Zip Code: 9,%7-Z3 Contractor's License Number: 91AEik14F94zV-Q Expiration. S 1zo ZZ Contact Person: "Sef-y �ssAtt4N Email: %Q)If 1"-COr-\ Electrical Contractor: Q 4 N S-Aa.t Jnw)c-, w>zr�t LL-c.- Phone Number: liz.S ?-LI4 )LfNs Address: 70 Ec7y-, 3711 City: P'd .F%c-. c J State: w Zip Code: �SZ23 Contractor's License Number: T3►af16Zt�F8N21�-t�l Expiration: I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws, rules and regulations of the State of Washington. de� _�� -71 1d7V7.0 — Applicants Signature date Print Applicants Name J, FOR STAFF USE ONLY ` �LD 12�Xl JUL 0 7 202P Permit# Accepted By i Amount Received Receipt# Date Received WEB Form-130 Page 1 of 1 6/16LP CITY OF ARLINGTON • 18204 59thAvenue NE,Arlington,IEA 98221 INSPECTIONS:360-403-34!7-Pen-nit Center 360-403-3551 BUILDING PERMIT 16415 Smokey Point Blvd Permit#:3302 Permit Expiration Date:01 061202I Parcel#:31052800201500 Valuation: 19250.00 OWNER APPLICANT CONTRACTOR RGB LLC B&H Fire and Security LLC B&:H Fire and Security,LLC 220 146TH PLACE SE PO Box 3711 PO Box 371 1 MILL CREEK,WA 98012 Arlington,WA 98223 Arlington,WA 9S22; 425-244-1445 425-241-1415 1.1 -:311FIRHF�42KW EXP:05i 16,2b22 MECHA LAICAL CONTRACTOR PLUMBING CONTR4CTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarin CODE YEAR: 2015 STORIES: 1 CONST.TYPE: - DWELLING UNITS: OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of any violation o1F this Code or any other ordinance or order of the City,of any stare or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the cxtenr the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order.proclaration,guidance advice or decision of ncc Governor of this State,this permit shall not authorize such work and shall not be valid_The building se of a structure where in violation of this Code,any other City ordinances of this official is authorized to prevent occupancy or u jurisdiction or any other ordinance or executive order of the City,or of any stato or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building ollicial is author,zs:d to:suspend or revoke This permit It it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation ofany Ciry ordinance,regulation or order-state or federal law,or any order.proclamation,guidance or decision of the Govcrnor. i AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE ST_V!-E OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.271_ -THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED RY THE BUILDING OFFICIAL OR HIS-HER DFPU I'Y AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDINGI OR STRUCTURE UNTIL A FINAL INSPECTION I IAS BEEN MADE,AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10`IRCI I0. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the Cin.of Ar imgton must be repotod on your sales tax return form and coded City of Arlingtor,#3101. C'o kut�'- Sr,nature Pant Name Date Re1c -sed By (` [Ate CONDITIONS L Permit and set of approved plans to remain on site during installation_ Installers shall present NICET 11 certification upon request.2. Battery load test required-switch FRCP and Power_Iviodnles{and communicatorkliaicr if provided ovith a battery back- Global Project VOW Honeywell Project Name Holman Recove Center Standby Hours: 24 ®SILENT' Project ID: 20-107 Alarm Min& irnlGtn Prepared By:FJTff Brossard berating Factor F 1 2 6700 Battery Calculator(SK) Date: 7/6/2020 Voltage Drop Warning Version 1 Threshold% Panel ID: 16700 1 Model: 6700 Add.Fire Alarm Control Panel Max NAC Current: 2.5 Amps Location: I S nnkler Riser Room Volta: 24 VDC Max Panel Current: 2 5 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ ° lo Ckt.# Circuit Name r?ty StandbyAlarm &T 1000 Ft, One-Way Ohms EOL Drop 6700 6700 CTRL Panel 1 1 0 165 0.310 SK-PHOTO Photo,Photo-T,PhotoR 0.000 0.000 SK-HEAT Heat,Heat-HT,ROR 0.000 0.000 SK-BEAM Beam, Beam-T 0.000 0.000 SK-DUCT Duct 0.000 0.000 SK-ACCLIMATE lAcclimate 0.000 0.000 SK-FIRE-CO FIRE-CO 0.000 0.000 SK-PHOTO-W Photo W 16 0.003 0.072 / SK-PHOTO-R-W'Photo-R-W 0.000 0.000 SK-PHOTO-T-W Photo-T-W 0.000 0.000 SK-HEAT-W Heat W 0 0.000 0-000 SK-HEAT-ROR- Heat-ROR-W 0,000 0.000 SK-HEAT-HT-W Heat-HT-W 0.000 0.000 SK-CONTROL Control 0 000 0.000 SK-CONTROL-6 Control-6 1 0-000 0.000 SK-RELAYMON- Rela Mon-2 0.000 0.000 SK-MONITOR Monitor,Minimon 3 0.001 0.015 SK-MONITOR-2 Monitor-2 0.000 0.000 SKMONITOR-10 Monitor-10 0.000 0.000 SK-PULLSA\DA Pull-SA,Pull-DA 1 0 000 0.005 4 SK-RELAY Relay 0.000 0.000 SK-RELAY-6 Relay-6 0.000 0.000 SK-ZONE lZone 0,000 0.000 SK-ZONE-6- Zone-6 0 000 0.000 SK-180 31 Isolator Module 0.000 0-000 B224BI Isolator Base 1 0.000 0.000 B200SR Sounder Base 0.000 0.000 6200S Intelligent Sounder Base 0,000 0.000 B200SR-LF Low Freq Sounder Base 0.000 0-000 6200S-1.F Low Freg Sounder Base 0 000 0.000 B224RB Relay Base 1 0.000 0.000 RTS151 Magnetic Remote Test 0 000 0.000 RTS151KEY Key Activated Test 0.000 0.000 RA100Z Remote LED 0 000 0.000 5860 LCD Remote Annunc, 1 0.020 0.025 5824 LCD Remote Annunc. 0 000 0.000 5496 Power Expander 0-000 0.000 5895XL Power Expander 0 000 0.000 5865.3 LED Annunciator 3G 0 000 0.000 5865-4 LED Annunciator 4G 0.000 0.000 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0 000 0,000 SK-NIC Network Input Card 0.000 0.000 SK-FML Muilti-Mode Fiber Card 0 0.0001 0.000 SK-FSL Single-Mode Fiber Card 0 0 000 0.000 NAC*1 NAC 1 0.000L0.21 #12 Solid 1 59 200 0'64 20.26 0.67% NAC#2 Booster Tri er 0000 #12 Solid 1 59 5 0,02 20.40 0.00% Total Stand Current(Am 0.190Total Alarm Current fAm SStand Time In Hours 24 Alarm Time In Minutes/60 5 MinsT I ui ed Total Alarm AH Required Total Combined AH Required 4.61 Command Shortcuts Multiply By The Derailing Factor 1.20 Minimum Battery Am Hours Required 5.64 Configure Circuits Print Page 7 AH Provided �. OFFICECOPY �L Oeiq�r--+a\e� ��'Y �►` KNUA I I Circuit Configuration Project Information Project Name: Holman Recovery Center Project ID: 20-107 Prepared By: Jeff Brossard Date: 7/6/2020 Ckt. Number: NAC#1 Panel ID: 6700 Ckt. Name: Notification Appl Circuit Use.Aux Power circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 P2WL 15cd 0.000 0.054 0.000 0.216 Unused 0 000 0 000 0 000 0 000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 0 000 0.000 Totals 0.000 0.216 Ckt. Number: NAC#2 Panel ID: 6700 _ Ckt. Name: Notification Appl Circuit Use:!Aux Power Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0 000 0.000 0.000 0.000 Unused 0.000 0.000 0 000 0.000 Unused 0 000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0 000 Totals 0.000 0.000 Global Project ValueT Project Name:I Holman Recovery Center Standby Hours: 24 Project ID: 20-107 Alarm Mins:� Prepared By: Jeff Brossard Derating Factor. 1 2 • '• - •. •- • Date: 7i612020 Voltage Drop Warning �. Threshold% 10 Panel ID: JHB1 Model. 5495 Power Expander Max NAC Current: 3.0 Amps Location: Sprinkler Riser room Volts: 24 VDC Max Panel Current: 6.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ o Ckt.# Circuit Name StandbyAlarm &Type 1000 Ft One-WayOhms EOL �oDrop 5495 5495 Pwr Module 1 1 0,075 1 0.205 NAC#1 HB1-1 0.000 0.609 #14 Solid 2.52 100 050 20.09 1.50% NAC#12 HB1-2 0,000 0.666 #14 Solid 2.52 100 050 2012. 1.37% NAC#3 HB1-3 0.000 0.460 #14 Solid 2.52 150 0.76 2005 1.70% NAC#4 HB1-4 0.000 0.657 #14 Solid 2.52 150 0.76 19.90 2.43% Aux 15495 Aux Power Out 0.000 0.000 #14 Solid 2.52 0,00 20,40 0.00% Total Standby Current Am 0,075 2.487 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 5 Mins) Total StandbyAH Required 1 800 0.207 Total Alarm AH Required Total Combined AH Required 2.01 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor, 1-20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery Am Hours Required Requiredl 2.41 7 AH PROVIDED — Configure Circuits Print Page Configuration" Circuit Project Information Project Name: Holman Recovery Center Project ID: 20-107 Prepared By: Jeff Brossard Date: 7/6/2020 Ckt. Number: NAC#1 Panel ID HB1 Ckt. Name: H81-1 Max Circuit Current. 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 6 SWL 15CD 0.000 0 043 0.000 0.258 1 P2WL 15CD 0.000 0 054 0.000 0 054 1 P2RK 75CD 0.000 0.176 0.000 0.176 1 P2WL 75CD 0 000 0.121 0 000 0 121 0.000 0 000 Totals 0.000 0.609 Ckt. Number: NAC#2 Panel ID HB1 Ckt. Name HB1-2 Max Circuit Current 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 SWL 15CD 0.000 0.043 0 000 0.172 3 P2WL 15CD 0.000 0 054 0.000 0 162 3 P2WL 30CD 0.000 0.074 0.000 0.222 Unused 0.000 0 000 0.000 0.000 0 000 0 000 Totals 0 000 0556 Ckt. Number: NAC#3 Panel ID HB1 Ckt. Name: HB1-3 Max Circuit Current 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 P2WL 30CD 0.000 0 074 0 000 0.148 1 P2WL 15CD 0 000 0 054 0 000 0 054 6 SWL 15CD 0.000 0 043 0 000 0.258 Unused 0.000 0 000 0 000 0.000 0 000 0.000 Totals 0.000 0.460 Ckt. Number NAC#4 Panel ID HB1 Ckt Name HB14 Max Circuit Current 3 Amps Qty vice Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 SWL 15CD 0.000 0.043 0.000 0.172 4 P2WL 15CD 0.000 0.054 0 000 0.216 2 P2WL 30CD 0.000 0.074 &000 0.148 1 P2WL 75CD 0.000 0.121 0.000 0.121 0.000 0.000 Totals 1 0 000 0.657 Ckt. Number. Aux Panel ID: HB1 Cfd_ Name: 5495 Aux Power Out Max Circuit Current 3 Amps aty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0 000 0 000 0 000 Unused 0.000 0 000 0.000 0.000 Unused 0 000 0 000 0 000 0.000 Unused 0 000 0 000 0.000 0 000 0 000 0.000 Totals 0.000 0.000 Global Project Values. SILENT I Project Name:I Holman Recovery Center Standby Hours: 24 KN I Gir I IT Project ID 20-107 Alarm Mins. Prepared By: Jeff Brossard Derating Factor 1.?_ 5495 Power .. de Calculations Date: 7/6/2020 Voltage Drop Warning Version 02 0. Threshold°k: 1G Panel ID: 1-11132 Model: 5495 Power Expander Max NAC Current 3.0 Amps Location: I Sprinkler Riser room Volts: 24 VDC Max Panel Current 6 0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ Ckt.# Circuit Name StandbyAlarm &Type 1000 Ft- One-WayOhms EOL G,Drop 5495 5495 Pwr Module 1 0,075 0.205 NAC#1 1-1132-1 0.000 0.755 1#14 Solid 2.52 150 0.76 19.83 2.80% NAC#2 1-1132-2 0.000 0.756 1#14 Solid 2.52 150 076 19.83 2.80% NAC#3 HB2-3 0.000 0.906 j#14 Solid 2.52 200 1.01 19.49 4.48% NAC#4 1-1132-4 0.000 0.604 #14 Solid 252 200 1.01 19.79 2.98% Aux 15495 Aux Power Out 0,000 0.000 #14 Solid 2.52 0.00 20.40 0.00% Total Standby Current(Amps) 0.075 3.225 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 (5 Mi Total Standby AH Required—1.800 0.269 Total Alarm AH Re uired Total Combined AH Required 207 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor, 1 20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery Am Hours Required 1 2.48 7 AH PROVIDED Configure Circuits Print Page Configuration Project Informatic7. Project Name: Holman Recovery Center Project ID: 20-107 Prepared By: Jeff Brossard Date: 7/6/2020 Ckt Number NAC#1 Panel ID: H82 Ckt Name. HB2-1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 SWL 15CD 0.000 0.043 0.000 0.215 5 HWL-LF 0.000 0108 0.000 0.540 Unused 0.000 0 000 0.000 0 000 Unused 0 000 0 000 0 000 0 000 0 000 0 000 Totals 0.000 0.755 Ckt, Number- NAC#2 Panel OrHB2 CM. Name: HB2-2 Max Circuit Current 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 SWL 15CD 0.000 0.043 0.000 0.215 5 HWL-LF 0.000 0.108 0.000 0.540 Unused 0.000 0 000 0 000 0.000 Unused 0.000 0.000 0.000 0.000 0 000 0 000 Totalsl 0.000 0.755 Ckt. Number NAC#3 Panel ID HB2 Ckt. Name. HB2-3 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 6 SWL 15CD 0.000 0 043 0.000 0.258 6 HWL-LF 0.000 0 108 0 000 0.648 Unused 0.000 0 000 0 000 0 000 Unused 0.000 0 000 0 000 0 000 0.000 0.000 Totals 1 0 000 0 906 " Ckt. Number: NAC#4 Panel ID: HB2 Ckt. Name: HB24 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 SWL 15CD 0.000 0.043 0.000 0.172 4 HWL-LF 0.000 0 108 0.000 0 432 Unused 0 000 0.000 0.000 0 000 Unused 0.000 0.000 0.000 0 000 0.000 0.000 Totals 0.000 0.604 Ckt Number Aux Panel ID H132 Ckt. Name: 5495 Aux Power Out Max Circuit Current. 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0 000 0 000 Unused 0.000 0.600 0 000 0 000 Unused 0.000 0.000 0 000 0.000 Unused 0.000 0.000 0.000 0 000 0.000 0 000 Totals 0 000 0 000 Honeywell SH-ENT 6700 Addressable Fire Alarm Control Panel The 6700 is an addressable fire alarm control panel(FACP) that can be configured to achieve an overall point capacity of up to 100 points.It has one built-in signaling line circuit (SLC),which can support 50 System Sensor'(SK)sensors and 50 SK modules or 50 Hochiki:1(SD)devices per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable.A designated panel is configured as the communicator for all panels in the link for convenient single-point communications.It also has a built-in,dual- line POTs and IP communicator and optional cellular side-cars. 6700 The 6700 system can be enhanced by adding modules such as the It supports a variety of devices,including the 6860 remote annunciator which also has four programmable function 6860,5860,and 6855 remote annunciators, buttons to help automate tasks and reduce time spent at the panel, 5824 serial parallel printer interface module(for printing system reports),the 5496 NAC expander, SWIFT"'wireless compatibility provides options forwireless 5895XL power module,and SK or SD devices, detection through a Class A mesh network.It is ideal for hard- to-wire locations,buildings where new wiring is not allowed,or to provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard-wired 6700 compatible devices.SWIFT is only compatible with System Sensor (SK)devices.It is not compatible with Hochiki(SD)devices. The 6700 also has Form C trouble relay,and two programmable Form C relays,along with powerful features such as drift compensation,pre- trouble maintenance alert,a built-in sensor test to comply with NFPA 72 calibration testing requirements,and calibration trouble alert. FEATURES & BENEFITS • Capable of providing • Convenient + 6860 annunciator with Programmable date 125 software lanes LII)to 100 points to field-upgradeable a 4 x40large display, setting for automatic., and 125 out.pW.. satisfysmaller firmware and 4 program mable and convenient groups for flexible installation needs Integrated dual path function buttons. Daylight Saving Time design options • Connect up to 17 IP and POTs Frae-up time spent at chances panels on one site with communications and the panel.Program Built-in dual phone convenient single- optional cellular then for simple or line and digital alai€n point access using the side-cars for reliable complex tasks. commL€nicatorf SK-NIC Network: backup Built-in US8 interface. transmitter(DACT)for Interface Card. for convenient and additional Connected panels can quick programming communication have mixed compatible options FACP models. 6700 Product Information SIGNAL LINE CIRCUIT(SLC) non-coded)signaling services. The 6700 SLC loops support multiple • UL Listed:S2766 device types,maintenance alerts,and a + built-in sensortestto comply with NFPA • CSFM 7165-0559:050 72 calibration testing requirements. • FDNY COA#6250 0 in 041c • Seismic(CA)(pending) INDICATOR LIGHTS 0 g • General Alarm(Red):Flashes if in son ORDERING INFORMATION alarm;solid when alarm is silenced 6700:Addressable Fire Alarm • Supervisory(Yellow):Flashes if a 6700 KEYPAD Control Panel,(Red cabinet) supervisory condition exists:solid PROGRAMMING COMPATIBLE ANNUNCIATORS when supervisory is silenced The 6700 system offers several options 6860:4x40 LCD remote fire • System Trouble(Yellow):Flashes to simplify and speed-up programming. annunciator(4 lines and up to if a trouble condition exists; JumpStart autoprogramming 160 characters)per system;four solid when trouble is silenced minimizes programming required to programmable buttons • System Silenced(Yellow): start a new system.The built-in keypad, Y 5860:4x20 LCD remote fire On when an alarm,trouble or or the 6860,5860 or 6855 remote annunciator.5860 is gray;r�860R is red annunciators give you on-site access supervisory condition has been 6855:4x20 LCD remote fire silenced but not yet cleared to current system programming.You can also program the system using annunciator • System Power(Green):Flashes the Honeywell Fire Software Suite 5865-3 or 5865-4:LED annunciators for AC failure;solid when (HFSS),which is Windows"'based. can display up to 30 LEDs(15 red and power systems are normal 15 yellow).The 5865-4 has key switches USER INTERFACE SOFTWARE TOOLS for silence and reset,and a system SKST:Silent Knight Selection Tool trouble LED. The 6700 built-in 4 x 20 annunciator provides the installer or design architect 5880:The 5880 LED/i0 module with 80 character LCD display with a Windows"software system has 40 programmable LED outputs and large easy-to-use tactile configuration toolto create a detailed and eight supervised dry contact touchpad can be used for system Bill of Material(BOM)and battery inputs which are useful for custom operation,programming and calculations. applications.You can use up to eight maintenance.It has five LEDs for alarm,supervisory,system trouble, HFSS:Honeywell Fire Software Suite 5880 modules on one control panel for system silenced and system power. provides communication and panel maximum flexibility,Its compact size programming,detector status,event allows mounting inside the annunciator, System operations include silencing history and additional data. Requires a or in an accessory cabinet. alarms and troubles,resetting alarms Windows-based computer. and the display of alarm troubles and memory.The systems non-volatile ADDITIONAL INFORMATION event history buffer stores 1,000 Twisted-unshielded pair wire is events for viewing from the built- recommended.T he 6700 also has in or remote annunciator.System 13 preset notification cadence operations can be initiated with a patterns(including ANSI 3.41). mechanical firefighter's key or a AGENCY LISTINGS AND APPROVALS valid 4-to 7-digit operator's code. NFPA 13,NFPA 15,NFPA 16,NFPA 70,NFPA 72:Central station;remote Signaling;Local Protective Signaling Systems;Auxiliary Protected Premises Unit;Water Deluge releasing service. Suitable for automatic,manual, waterflow,sprinkler supervisory(DACT .J 6700 COMPATIBLE DEVICES AND B200S-LF:Low-frequency intelligent smoke detector ACCESSORIES sounder base WSK-PHOTO-T:Wireless Multi-criteria See the data sheets listed belowfor a B224RB: Relay base photoelectric smoke detectorwith thermal complete listing of the SK,SD orSWIFT B224B1: Isolator base detection(135°Ffixed temperture)and devices. B510W 4"base 53623:SK Devices Data Sheet SD COMPATIBLE ADDRESSABLE WSK-HEAT:Wireless Heat,(1351F fixed 53624:SD Devices Data Sheet DEVICES temperture)and B510W 4"base 350614,350616&350618:SWIFT SD505-6AB:Addressable 6"base WSK-HEAT-ROR:Wireless heat,POP wireless devices SD505-61B:Addressable 6"short circuit (135oFfixed temperture)and B510W 4" For a complete and current listing of isolator base base compatible devices and accessories go to SD505-6RB:Addressable 6"relay base WSK-MONITOR:Wireless monitor module www.sitentknight.com SD505-6SB:Addressable 6"sounder base WSK-RELAY:Wireless relay module Important:You cannot mix SK and SD SD500-AIM:Addressable input module W-USB:SWIFT Tools US13 transceiver used devices in the same fire alarm system. (switch input) for communication with SWIFT devices SK COMPATIBLE ADDRESSABLE SD500-ANM:Addressable notification DEVICES module SBUS ACCESSORIES SK-ACCLIMATE:Multi criteria SD500-ARM:Addressable relay module 5496:A 6 amp notification power expander photoelectric smoke detectorwith thermal SD505-DTS-K:Remote test switch and with four power-limited notification 1351Ffixed temperture LED indicatorforthe SD505-DUCTR appliance circuit outputs. SK-BEAM:Reflected beam smoke detector SD505-DUCT:Addressable Duct Smoke 5883:Relay interface.Provides 10 Form C without test feature Defector. relays. SK-BEAM-T:Reflected beam smoke SD505-DUCTR:Addressable Duct 5824:Serial/Parallel printer interface detectorwith testfeature Detector housing with relay base, module for printer connection. SK-CONTROL:Supervised control module SD505-HEAT:Absolute temperature 5895XL:Power supply with six FlexputT" SK-CONTROL-6:Six circuit supervised heat detector.Trip point range from circuits,and two Form C relays.Max.16 per control module 1350 E-150o F(0 C-37o C). system. con conDUCT:Photoelectric duct smoke SD500-LIM:Addressable Line isolator 5B15RMK:Remote mounting kit. SK- module Dimensions 10 3/8"V1 x 10-3/16"H x 3"D detectorwith extended airspeed range SD500-MIM:Addressable Mini input SK-FIRE-CO:Four criteria fire and carbon monitormodule(switch input) COMMUNICATION OPTIONS monoxide detector SD505-PHOTO:Photoelectric smoke CELL-CAB-SK:Cellularconimunicator, SK-HEAT:Fixed thermal detector(1350F) detector metal enclosure with lock/key* SK-HEAT-ROR:Fixed rate of rise detector SD500-PS/-PSDA:Addressable Single or CELL-MOD:Cellular communicator,plastic (135°F) dual action pull station enclosure* SK-HEAT-HT:Fixed high temperature SD500-SDM:Addressable smoke detector "Sole path,powered by panel. thermal detector(190°F) module IPGSM-4G:Dual path fire alarm SK-ISO:Fault isolator module communicator.cellular and/or IF(primary SK-MINIMON:Mini monitor module AUDIBLE/VISIBLE DEVICES or backup,selectable) SK-MONITOR:Monitor module These AV devices are all 2-wire.Color"R" SK-I113-2:Remote reporting via the Internet. SK-MONITOR-2:Dual input monitor indicates red i'W"denotes white.For a Requires a VisorAlarrn"receiver atthe module complete listing of Silent Knight AV devices central station SK-MON-10:10 input monitor module go to www.silentknight,com, SK-PHOTO:Photoelectric smoke detector CHSRL/CHSWL:Wall chime/strobe MISC.ACCESSORIES SK-PHOTO-T.Photoelectric smoke CHSCRL/CHSCWL:Ceiling chime/strobe SK-NIC:Network Interface Card.Provides a detector with thermal(135oFfixed CHRL/CHWL:Wall chime common communications link for the 6700 temperture) HRL/HWL:Wal horn SK-NIC-KIT:Installation Accessory Kit SK-PHOTOR:Photoelectric detectorwith P2RL/P2WL:Wall horn/strobe SK-FML:Fiber-Optic Multi Mode, remote test ca abilit transmitter and receiver P Y PC2RL/PC2WL:Ceiling horn/strobe SK-PULL-SA:Addressable single action SRL/SWL:Wall strobe SK-FSL:Fiber-Optic Single Mode pull station RBB:Remote battery box accessory cabinet SCRL/SCWL:Ceiling strobe for batteries that are too large to fit in the SK-PULL-DA:Addressable dual action pull SPSCRL/SPSCWL:Ceiling speaker/strobe FACP cabinet.Dimensions:16"W x 10'H x station SPSRL/SPSWL:Wall speaker/strobe 6"D(406rrim W x 254mm H x 152i7irn D), SK-RELAY:Addressable relay module SK-RELAY-6:Addressable Six relay control SPRL/SPWL:Wall speaker SK-SCK:Seismic Compliance Kit used to SPCRL/SPCWL:Ceiling speaker securelyfasten batteries to the fire pane. module SK-RELAYMON-2:Addressable Dual relay/ SWIFT WIRELESS DEVICES monitor module SK-ZONE:Addressable zone interface SWIFT is only compatible with module System Sensor(SK)devices.It is not SK-ZONE-6:Six zone interface module compatible with Hochiki(SJ)devices. B210LP:6"mounting base WSK-WGI:Wireless Gateway B501:4"Flangeless mounting base WSK-PHOTO:Wireless Photoelectric B200S:Intelligent sounder base F 6700 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS(NACs) For a complete listing of all Overall Dimensions:12,71"W x 15.12'H x 3.33"D Two programmable circuits which can be compliance approvals and Weight:l5tbs. programmed individually as: certifications.please visit 9 Y Color:Red NACs:2.5A g 27.4VDC per circuit,power-limited www.s i ie nt kn i g ht.c o m. (with a panel maximum current of 2.5A) Microsoft,Windows and ENVIRONMENTAL Auxiliary Power Circuits:2.5A ia,27.4VDC per the Windows Logo are Operating Temperature:32°F to 120°F (0°C to circuit,power-limited registered Lradernarksortrademarks of 49°C) Microsoft Corporation, Humidity:0 to 03%relative humidity(non- Supports Class B(Style 4)and Class A(Style 6 or 7) condensing) configuration forthe SLC Silent Knight",Honeywell' and SWIFT°are registered ELECTRICAL trademarks of(Honeywell WIRING:See the product manual for wiring details intemational.lnc. 6700 Primary AC:120 VAC @ 60 Hz,1.5ATotal Accessory Load:2.5A @ 27.4 VDC power-limited This document is not intended to be used for Standby Current:165mA installation purpo_ses.We Alarm Current:310mA try to keep our product Battery Charging Capacity:7 to 35AH information up-to Battery Size:7AH max.allowed in control panel date an accuraLe.We cannot cover all specific cabinet.Larger capacity batteries can be housed in applications or anticipate RBB accessory cabinet.. all requirements.All specifications are subject to change without notice. For Technical Support, call 800-446-6444. For more information Learn more about H oneywell Si Lent Knight and other products by visiting www.siLentknight.com Honeywell Silent Knight 12 Clintonville Road N orthfo rd.CT 06472 351607 1 A 1 11/17 H o n eywe I I 800-328-0103 ©2017 Honeywell International Inc. 0 FIRE SYSTEM ACCESSORY 3 SILENT Model 5495 KNIGHT Distributed Power Module In an emergency, by Honeywell you need maximum power The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor@,Gentex®,AMSECO®, Wheelock and Faraday—what you need to drive power- hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies.And,ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-328-0103. Model 5495 to non-essential high-current Distributed Power Module accessories like magnetic door holders The 5495 is a 6 amp notification power Built-in synchronization for expander that provides its own AC appliances from System power connection, battery charging Sen antes from , stemAMS ®, circuit, and backup battery for use with Wheelock and Faraday fire and security controls such as the Silent Knight Model 5208 Fire Control Stand alone operation /Communicator.The 5495 is the cost- Lightweight design adds to ease of effective solution for powering installation and reduces shipping notification appliances required by the costs Americans with Disabilities Act(ADA). Operates with most polarized, UL The 5495 has built-in ANSI cadence Listed notification devices pattern,which can upgrade older control panels that lack cadence ANSI Cadence pattern output capability. capability built-in Features Connection to Local Fire Control • UL Listed for 6 amps of notification The 5495 may be connected to a local Model 5495 fire control which utilizes Class A or power Class B type notification circuits Distributed Power Module • Power supply's advanced switch operating between 9 and 32 VDC.The mode design reduces damaging control panel's notification circuit is Approvals heat and manages power up to 50% connected to one of the inputs on the UL Listed more efficiently than other systems 5495.The control panel's notification MEA 429-92-E Vol XII • Dip switches allow for easy circuit end-of-line resistor is also CSFM 7300-0559:123 reconfiguration connected across two terminals on the NFPA 72 • 24 VDC filtered output voltage 5495,which provides supervision • Four power-limited notification between the 5495 and the fire control outputs; 2 Class A or 4 Class B, or 1 panel. Polarized audible and/or visual Class A and 2 Class B notification devices are then connected • Additional continuous auxiliary to the 5495 signal circuits using the output 4.7kQ end-of-line resistors provided. Since the 5495 draws very little power • 3 amps per output circuit from the control, it is possible to • 2 inputs; 2 Class B or 2 Class A connect one 5495 to each notification • Ground fault detector/indicator circuit on the control panel and still • Independent trouble relay provide full supervision of the • AC loss delay option shuts off power notification circuits all the way back to the control panel. FIRE SYSTEM ACCESSORY 0 Model 5495 Distributed Power Module Model 5495 Block Diagram Signal Circuit Output Signal 1 ` Signal 1 Input 1 Distributed Signal 2 Signal Circuit Output Signal 2 Power Input Module 5495 Signal 3 (Optional) Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9 - 32 VDC functions including: Alarm 205 mA Battery charging • Low AC power Auxiliary capacity: 35.0 AH • Low battery condition power circuit: 1 Ambient temp.: 32'to 120' F • Earth ground fault Notification (0' to 49' C) • Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25"W x 16" H x • EOL supervision trouble or configuration: 2 Class A(Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights the 5495 creates a trouble condition on the host control signal Amps per AC power on : Green circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC addition, the 5495 provides a Form @ 3.0 amps each, Aux trouble: Yellow C trouble relay output as an 4.7 kQ EOL Output troubles (1-4): Yellow alternative to using the notification resistor required Ordering Information circuit trouble. on each Class B 5495 Distributed Power Module circuit Electrical Specification AC input: 120 VAC at 2 amps Input I Output: 24 VDC at 6 amps nputt inputs 2 configuration: 2 Class B or 2 Class A SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350395 Rev D a subject to change without notice.For more information,contact Silent Knight ©2010 Honeywell International Inc. by Honeywell 12 Clintonville Road,Northford,CT 06472-7161 Phone:(800)328-0103, Fax: (203)484-7118.www.silentknight.com 0 0 INTELLIKNIGHT ACCESSORY SILENT 5860 Remote Annunciator KNIGHT by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility. Now you can operate and program your IntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation.All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description multiple 5860s Features include an 80-character • RS-485 interface to panel backlit LCD providing easy-to- • Operation and appearance is understand system messages. The identical to 5860 built-in annunciator is ergonomically annunciator designed with over-sized buttons • On-board piezo sounder audibly for the most frequently used indicates alarms, troubles, and features, like Reset and Silence. supervisories In addition to status messages • Five status LEDs for alarm, supervisory, trouble, silence and displayed on the LCD, there are AC power conditions five LEDs for alarm, supervisory, - Wiring lengths up to 6000 ft. from trouble, silence, and AC power the FACP (depending on wire status. gauge and number of devices on 5860 The annunciator is available in gray SBUS) Environmental to match virtually any decor and • UL listed, complies with NFPA 72 Operating Temperature: 320F— red for applications where the • CSFM approved 120°F (0°C—49°C) annunciator must stand out.The Electrical Specifications Humidity: 10%—93% non- annunciator enclosure can be Operating Voltage: 24 VDC condensing surface or flush mounted.A trim Standby Current: 20 mA max Compatibility ring kit is available for surface The 5860 is compatible with the mounting. Alarm Current: 25 mA following FACP'sP Wiring Distance: 6,000 max. from Features FACP (depending on wire gauge • 5820XL Addressable Fire Control • 80-character backlit LCD display and number of devices on the Panel (4 lines with 20 characters on SBUS) • 5820XL-EVS FACP with each line) Emergency Voice System • Tactile and audible feedback Max Per System: 8 • 5808 Addressable Fire Control • Accepts user codes or fire Mechanical Specifications Panel fighter's key Physical 9.1" W x 7.4" H x 1.5" D • Larger keypad buttons for stem 5700 Addressable Fire Control 9 �/P Y (23.1 W x 18.8 H x 3.8 D cm) Panel reset and silence • Install up to eight 5860s per Shipping Weight: 2.8 Ibs (1.3 kg) Listings FACP Color NFPA 72; UL Listed; • Available in red or light gray 5860R: Red CSFM 7170-0559: 135; • Support for simultaneous use of 5860: Gray MEA 429-92-E Vol. IX; FM Approved ACCESSORYINTELLIKNIGHT 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator.All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of.040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. WbV am DM 60 an PW I" PAR letJi 'Ai0 'Aid 9�i0 Comodillift fry Ordering Information 5860R Remote Annunicator four line LCD annunciator with 20 characters per line. Red. 5860 Remote Annunciator.Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring for surface mounting. 5860TG Gray Trim Ring for surface mounting. SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350224 Rev F subject to change without notice.For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-1610.Phone: (800)328-0103, Fax:(203)484-7118.For Technical Support, Please call 800-446-6444. www.silentknight.com Honeywell sn.�rr KMGNI' SK-PHOTO-W Series Intelligent Plug-In Photoelectric Smoke Detector Honeywell Silent Knight SK-PHOTO-W Series plug-in smoke detectors are designed for both performance and aesthetics.A new modern,sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Serifs detector sensitivity can be programmed in the control panel software.Sensitivity is continuously monilored and reported ` to the panel.Point ID capability allows each detector's address to be set - with rotary,decimal address switches,providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F(57°C)fixed temperature thermal sensing on the SK-PHOTO-T-W.The SK-PHOTO-R-W Is a remote test SK-PHOTO-W capable detector for use with DNR Series duct detector housings. FEATURES &' BENEFITS • New rmadern profile for Dual LED design Expanded color Optional relay, improved aesthetics provides 3601 viewing Options isolator,and sounder • Stable communication angle S"EMS screws for bases technique with noise Rem ate test feature wiring of the separate Plugs into separate iimmunity from the panel base base for ease of • Lowstandby current Built-infunctionaltest install.at€on and switch activated by maintenance • Two-wire SI_C connection external magnet • Optional remote, Built-in tamper- smgle-gangLED resistant feature accessory Sealed against back pressure DETECTOR SPACING AND INTELLIGENT BASES ACCESSORIES APPLICATIONS B300-6:White,standard flanged CK300:Color Kit(includes cover and Honeywell recommends spacing low-profile mounting base. trim ring),white,10-Pack. detectors in compliance with NFPA 72. B300-6-BP:Bulk pack of B300-6, CK300-IV: Color Kit(includes cover In low airflow applications with smooth package contains 10. and trim ring),ivory,10-Pack. ceiling,space detectors 30 feet(9m). B300-6-IV:Ivory,standard flanged CK300-BL:Color Kit(includes cover For specific information regarding low-profile mounting base. and trim ring),black,10-Pack. detector spacing,placement,and B501-WHITE:White,star lord M02-04-01:Detector test rnagnet. special applications referto NFPA 72. European flan eless mounting base.UL p g� 9 M02-09-00:Telescoping test magnet. System Smoke Detector Application listed. RAIOOZ:Remote LED annunciator Guide,documentA05-1003,is available at systemsensor.com B501-BL:Black,standard European SMB600:Surface Mounting Kit flangeless mounting base.ILL listed. (flanged). INSTALLATION B501-IV:Ivory,standard European TR300:Replacement trim ring for The SK-PHOTO-W Series plug-in flangeless mounting base.UL listed. B300-6,white. detectors use a separate base to B200S-WH:White.intelligent, TR300-IV:Replacementtrimring for simplify installation,service,and programmable sounder base. B300-6-IV,ivory. maintenance.Installation instructions B200S-IV:Ivory,Intelligent, are shipped with each detector. programmable sounder base. B200SR-WH:White,Intelligent sounder Mount base(all base types)on an base for retrofit applications. electrical backbox which is at least 1.5" B200SR-IV:Ivory,Intelligent sounder (3.81 cm)deep. base for or retrofit applications. NOTE: B200S-LF-WH:White,Low Frequency •Because of the inherent supervision Intelligent,programmable sounder base. provided by the SLC loop,end-of-line resistors are not required.Wirinq B200S-LF-IV:Ivory,Low Frequency "T-taps"or branches are permitted for Intelligent,programmmable sounder Style 4(Class"B")wiring. base. B200SR-LF-WH:White,Low •When using relay or sounder bases, Frequency Intelligent sounder base for consultthe installation sheet for device retrofit applications. limitations between isolator modules B200SR-LF-IV:Ivory,Low Frequency and isolator bases. Intelligent sounder base for retrofit applications. ORDERING INFORMATION B224RB-WH:White,plug-in System SK-PHOTO-W:Photoelectric smoke Sensor relay base. detector,white. B224RB-IV:Ivory,ping-in System SK-PHOTO-R-W:Photoelectric smoke Sensor relay base. detector,remote test capable,for use B224BI-WH:White,plug-in System with DNR(W)duct smoke detectors, Sensor isolator detector base. white. B224B1-IV:Ivory,plug-in System SK-PHOTO-T-W:Photoelectric smoke Sensor isolator detector base. detector with thermal sensing,white. r SK-PHOTO-W Series Detector Technical Specifications PHYSICAL COMPATIBILITY Fora complete listing of all compliance approvals and Height:2.0"(51mm)installed in B300-6 base The SK-PHOTO-W series detectors are certifications,please visit Diameter:6.2"(156mm)installed in 8300-6 compatible with the following Honeywell Silent ^,w.sRentknigInt.corr. base 4.1"(104 mm)installed in B501 base Knight fire alarm control panels: Microsoft,Windows,and the Windows Logo are Weight:3.4 oz(95 g) 6820:Addressable fire alarm control panel registered trademarks 6820EVS:Addressable fire alarm control panel ortrademarks of ENVIRONMENTAL Microsoft Corporation, Silent Knight",Operating Temperature range: with an emergency voice system. Sy stern 6808:Addressable fire alarm control panel Sensor-and Honeywell Photo:32°Fto 122eF(0°C to 50°C) are registered 6700:Addressable fire alarm control panel trademarks of Honeywell Photo with Thermal:32°F to 100eF(0°C to internationai.Inc. 38°C) 5700:Addressable fire alarm control panel 5808:Addressable fire alarm control panel This document is not UL listed Velocity range:Photo/Photo with intended to be used for 5820XL:Addressable fire alarm control panel instal:-ation purposes.We Thermal:0 to 4,000 fpm(0 to 20 m/sec) tryto keep our product (suitable for installation in ducts) 5820XL-EVS:Addressable fire alarm control �nforrnahcn up-to o p panel with an emergency voice system date andaccurate,We Humidity:l0 /a to 93 /o non-condensing cannot cover allspecific applications or anticipate Thermal Ratings:Fixed Temperature Set point: AGENCY LISTINGS AND APPROVALS all requirements.All 135eF(57°C) For exact certification listings for each model, specifications are subject please reference the respective agency Web site. to change without notice. ELECTRICAL RATINGS UL listed:S6173 For Technical Support, Voltage Range:15 to 32VDC peak FM approved call800-446-6444. CSFM:7272-0559:0523 Operating Current @ 24VDC:200pA(one communication every 5 seconds with green LED blink on communication) Maximum Current:4.5mA ra)24VDC(one communication every 5 seconds with amber LED solid on)- For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 Doc 3516341 Rev A 1 04/18 SII_E-r 800-328-0103 C 2018 Honeywell International Inc. ©KllCi U ACCESSORYINTELLIKNIGHT 3 SILENT SK-Pull-SA and SK-Pull-DA KNIGHT by Honeywell Intelligent Pull Stations The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition • Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition SK-Pull-SA • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Meets ADA requirement for 5 Ibs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® • Reliable analog communications for trouble-free operation • Braille text on station handle SK-Pull-DA • Handle latches in down position and the word Activated Compatibility appears, clearly indicating the station has been pulled The SK-Pull-SA and SK-Pull-DA are compatible • Rotary address switches for fast installation with the following IntelliKnight FACP's: 5600 • UL Listed, including UL 38, Standard of Manually Actuated 5700 Signaling System 5808 5820XL ACCESSORYINTELLIKNIGHT Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans,Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. Class A IN . ..._..._.—"-- .—...__...............................................�........................ ._..____._.M_.«_.._..._. *LC OUT Class B Compatible FACP ne ee 1 i i i a a a a a • 1 1 l 1 Class A-ring: Cless B Wring: a� 7 Wiring SK-Pull-SA&SK-Pull-DA Pull Stations Specifications Electrical Physical Operating Voltage: 15-32 VDC Height: 5.5"(14 cm) Average Operating Current(LED flashing): 300 pA Width:4" (10.2 cm) Wire Gauge: Up to 12 AWG (3.1 mm2) Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 321—120°F (0°C—49°C) Bi-Colored LED: Humidity: 10%—93% non-condensing Blinking Green: Normal Steady Red:Alarm Accessories Switch: Single pole, single throw(SPST)normally open (N/O) BG-TR Optional trim ring. switch which closes upon activation of the pull station SB-1/0 Surface backbox SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA to keep our product information up-to-date and accurate.We cannot cover KNIGHT all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent FORM#350135 Rev B ©2012 Honeywell International Inc. Knight 12 Clintonville Road, Northford,CT 064 72-1 61 0 by Honeywell Phone: (800)328-0103, Fax: (203)484-7118. www.silentknight.com INTELLIKNIGHT ACCESSORY SILENT SK-Monitor KNIGHT m by Honeywell Intelligent Monitor Module The SK-Monitor module provides an interface to contact devices, such as security contacts, waterflow switches, or pull stations. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Monitor is an addressable monitor module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs).The SK-Monitor is intended for use in intelligent, two-wire systems, where individual address of each module is selected using the built-in rotary switches. The SK-Monitor supports Class A supervised or Class B supervised wiring to the load device. Conventional 4-wire r"'•- �' smoke detectors can be monitored for alarm and trouble Z"'`�` �'•. l�i�.. •. conditions. ,4 mot_ �''►���•\ 'Yy Features • Single contact monitor • Support for Class A and Class B wiring • Fully supervised • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Attractive ivory cover plate SK-Monitor • Rotary address switches for fast installation • SEMS screws for easy wiring Specifications • UL Listed Physical Installation Height: 4.5" (11.4 cm) The SK-Monitor mounts directly into a 4" square electrical Width: 4" (10.2 cm) box. The box must have a minimum depth of 2-1/8".A Depth: 1.25" (3 cm) surface mount electrical box (System Sensor® PN Shipping Weight: 6.3 oz (196 g) SM13500) is available from Silent Knight. Electrical Compatibility Operating Voltage: 15—32 VDC The SK-Monitor is compatible with the following Current Draw (LED on): 5.0 mA max IntelliKnight FACP's: Operating Current (LED flashing): 375 pA 5700 5808 5820XL 5820XL-EVS INTELLIKNIGHT ACCESSORY 10 Model SK-Monitor Intelligent Monitor Module 'W.NEXT IN=FIIJEL CM t &WNI1&A8El1CFt&UffTMCEMCr CLIG81011EDEVICESAMMURMWNWMIN OCINIIIIEUr MDELLA.EB77 UITTW ca, ;E ffWNAMWWMMFS%WCW.DR D O CALf%NIEL8Clay SEDINUMIDEWUMBONTHE&MffiW13EIULE • .. °METIL c5 1 �S*NAL UN:CRCLdT(SLq RESWIZIRi 32WCMAX Ft-17tC «< s • TwEr EU FYtI+I IS I 0RVff1NTI,Ce=EUFXM JEO)-NM UTLE H FEELLWREEI.46"MIML.a tf VW MAX BUIALLCUIMUMMM DEWHIERpER ALLY SHIPA F IS BU ERWSELI AMPOWER LWrM UANLNWCTUFNEFMIWALLM=DiST,faFCTMM. 2-Wire Initiating Circuit Configuration, NFPA Style B TO NExr FIFIGM PN EL OR DEVICE PREVIOUS DEVICE MDNnM ANY NtIiBER OF UL LISTED CONTACT MODULE CLOSL/iE DEVICES MAY BEUSED.DO NOT MIX i CONNECT MODULES TO LISTEDOOMFWIBLE FIRE ALARMINTLgIKN3,SUPERVISORY OR ` NOTFER CONTROL PIV/ELSONLY BECUAITY DEVICES ON THE SMEMOWLE. n t t�l nr 92 VDC MAX. EOL AESNIUMf8 1 c a- L.DED-7WIffr£Of%R INTERNALAr — n / IS� TEFMIN AL6 B l5 J REflOI aBNDED IIBTALt_CONTACT CLOSILME DEVICES Pit ALL WIRNG SHOWN 38 BILFEWRETI AND POWER LIMITED MANUFACTU14:1TS IiSTALLIQION IMSTFKMOM 4-Wire Initiating Circuit Configuration, NFPA Style D Standby Current: Environmental 400 pA max @ 24 VDC (one communication every 5 Operating Temperature: 320F— 120OF (0°C—49°C) sec with 47K EOL) Humidity: 10%—93% non-condensing 550 pA max @ 24 VDC (one communication every 5 sec with EOL<1 K) Ordering Information 5.5 mA(with LED latched on) SK-Monitor Monitoring Module LED Current: 5.5 mA(with LED latched on)End-of-Line Resistance: 47K E2 Accessories Initiating Device Circuit Wiring Resistance: 1,500 52 max SMB500 4" Square Surface Mount Electrical SLC Loop Resistance: 40 0 max. Box SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice.For more information,contact Silent Knight FORM#350131 Rev D by Honeywell 12 Clintonville Road,Northford,CT 06472-1610 Phone:(800)328-0103, ©2013 Honeywell International Inc. Fax: (203)484-7118. For Technical Support,Please call 8200-446-6444. www.silentknight.com SYSTEM .SENSOR I,I,I,I,I t Indoor Selectable. I I Output Horns R Out p � E E Strobes, and ' Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut ? 1i installation times and maximize profits with lower current draw and modern aesthetics. Features f • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and rnodern aesthetics.With white and red • Plug-in design with minimal intrusion into the back box plastic housings,standard and compact devices,and plain, FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela The L-Series line of wall-mount horns,strobes,and horn strobes • Field-selectable candela settings on wall units: include a variety of features that increase their application versatility 15,30,75,95, 110, 135, and 185 while simplifying installation.All devices feature plug-in designs • Horn rated at 88+dBA at 16 volts with minimal intrusion into the back box,making installations fast • Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming ground faults, • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,the L-Series utilizes a universal mounting plate for all • Electrically Compatible with legacy SpectrAlert and SpectAlert models with an onboard shorting spring,so installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings, automatic,selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING usreo S5517 FM approved except 11 ZS'E53 nl0" S4011 for Al.FRT models 71351E53 50? 3057333 3057C72 I L-Series Specifications Architect/Engineer Specificalions General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/n inch back box,4 x 4 x 114-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/a-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30.75.95, 110, 135.and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32'F to 120'F(0'C to 49'C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR'.2 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 1210 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 1.91-D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 86 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7-W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133mm L x 68mm W x 32mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. • UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA WAS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mARMS).2-Wire Horn Strobe,Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-A ern portal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K'iemporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non-Iernporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1 K Non-Temporal High 104 131 177 204 230 264 326 3.1 K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 64 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9. Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 'Settings 9 and 10 are not available on the 2-wire horn strobes. L-Series Dimensions 1.91 3.46 r 3.46 - 1.25 �r ti 125 o°R, 000a o°o°o°o°o°oa 5.27 5,27 °00000°o°oo; Compact Strobe/Horn Strobe Compact Horn - 4.70 1.25 4.70 - - - 1.25 '�— Ali - � l 5.67 .67 Strobe/Horn Strobe Horn L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns P2RL 2-Wire,Horn Strobe,Red HRL Horn,Red P2WL 2-Wire,Horn Strobe,White HWL Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL Compact Horn,Red P2GWL 2-Wire,Compact Horn Strobe,White HGWL Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2Wl.-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WI.SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red Wall Strobes SBBWL Wall Surface Mount Back Box,While SRL Strobe,Red SBBGWL Compact Wall Surface Mount Back Box,Red SWL Strobe,White SBBGWL Compact Wall Surface Mount Back Box,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"markino on cover All-ALERT models have"ALERT'marking cn cover 3825 Ohio Avenue•St.Charles, IL 60174 @2or?SysamSensor. SYSTEM h Phone:800-SENSOR2•Fax:630-377-6495 Pmdu-tspeeica;onssubjecttcchangewmou;no6c?.vistsystemsensoccom �Cw IS OR y for current pieduct i�fnrm<:[ion,SMS0 g the latest ver on of this data shcet- e'V www.systemsensor.com AVC]FBSSD3.03117 SYSTEM SENSOR Indoor Selectable- Output Low Frequency Sounders and Low Frequency Sounder Strobes System Sensor L-Series audible visible notification E products are rich with features guaranteed to maximize profits with lower current draw and modern aesthetics. Features The L-Series offers the most versatile and easy-to-use line of low • 520 Hz± 10%square wave tone, NFPA compliance frequency sounder and low frequency sounder strobes in the industry.With white and red plastic housings,listed for wall and • Full candela range plus High/Low tone options to optimize current ceiling mounting, L-Series Low Frequency can meet virtually any draw for a wide variety of applications application requirement. • Compact,standard,and round ceiling options The low frequency sounder and low frequency sounder strobes were • Field-selectable candela settings on wall units: 15,30,75,95, designed to address the NFPA 72 sleeping space requirements that 110. 135,and 185 require a low frequency notification appliance that operates within • Rotary switch for High and Low,Temp3 and Temp4 settings frequency range of 520 Hz i 10%and is of a square wave tone.Like • Plug-in design with minimal intrusion into the back box the entire L-Series product line they include a variety of features that increase their application versatility while simplifying installation.All • Mounting plate shorting spring checks wiring continuity before devices feature plug-in designs with minimal intrusion into the back device installation box,making installations fast and foolproof while virtually eliminating • Electrically compatible with legacy SpectrAlert and SpectrAlert costly and time-consuming ground faults. Advance devices(Direct replacement for HW/R-LF and P2R/WH-LF) To further simplify installation and protect devices from construction damage, L-Series uses a universal mounting plate with an onboard • Compatible with MDL3 sync module shorting spring,so installers can test wiring continuity before the • Sounders listed for ceiling and wall mounting device is installed. • Sounder Strobe listed for wall mounting Installers can also easily adapt devices to a suit a wide range of • Updated modern aesthetics application requirements using field-selectable candela settings,24- volt operation,and a rotary switch for 520 Hz low frequency sounder tones. Agency Listings SIGNALING@ �JL FM LISTED arrnawn S40i1 11111711 HorsIly 7135-1553:05'6 HOr,V'[r cs 7125-1653M,17 AVOS910-01•-:Oi/2019•P-,1 L-Series Specifications General L-Series low frequency sounder and low frequency sounder strobes shall mount to a standard.4 x 4 x 1 Yz-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 1%-inch back box.A universal mounting plate shall be used for mounting products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'°"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module,24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit(0°C to 49°C)from a regulated DC or full-wave rectified unfiltered power supply.Low Frequency Sounder strobes shall have field-selectable candela settings including 15,30,75,95, 110, 135, 185.The field selectable tones will sound within the frequency range of 520 Hz±10 square wave tone and have a permanent marking on the housing that reads"low frequency sounder". Low Frequency Sounder The low frequency sounder shall be a System Sensor I_Series Model listed to UL 464 and shall be approved for fire protective service.The low frequency sounder and the Sync•CircuitTM MDL3 Module accessory,if used,shall be powered from a notification appliance circuit output and shall operate on a nominal 24 volts(includes fire alarm panels with built-in sync).When used with the Sync-Circuit Module MD1_3,24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts.If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used,then refer to the compatibility listing of the panel to determine maximum devices on a circuit.The low frequency sounder has an option to switch between temporal three or temporal four pattern.non- temporal(continuous)pattern and coded supply within the frequency range of 520Hz±10 o square wave tone.The low frequency sounder shall operate on a coded or non-coded power supply with high and low volume settings. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The sounder shall have an option to switch between a temporal three or temporal four pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply with high and low volume settings. The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three.Also,while operating the strobes,the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires.The module shall mount to a 4"Ac,x 4iV,a x 2'/8-inch back box.The module shall also control two Class B circuits or one Class A circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 320F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Frequency Range 520 Hz±10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 24 DC/FWR1 Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Dimensions Wall Sounder Strobe(including lens) 5.6"L x 4.7"W x 1.9"D(142 mm L x 119 mm W x 49 mm D) Standard Wall Sounder 5.6"I.x 4.7"W x 1.5"D(142 mm L x 119 mm W x 38 mm D) Compact Wall Sounder 5.25"L x 3.46"W x 1.5"D(133mm L x 88mm W x 38mm D) Ceiling Sounder 6.8"diameter x 1.4"high(173mm diameter x 36mm high) Standard Wall Sounder with SBBRUSBBWL Surface 5.7"L x 4.8"W x 3.3"D Mount Back Box (145 mm L x 120 mm W x 87 mm D) Compact Wall Sounder with SBBGRUSBBGWL Surface 5.4"L x 3.6°W x 3.0"D(137 mmL x 91mm W x 76 mm D) Mount Back Box Low Frequency Ceiling Sounder with SBBCRL/SBBCWL 6.9"diameter x 3.9"high(175mrn diameter x 99mm high) Surface Mount Back Box Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. AVDS910-01•101'12.019•Page 2 UL Current Draw and Sound Output Data Low Frequency Wall Sounder Strobe Current Draw(mA)and Sound Output(dBA) Sound Current Draw(mA) Output dBA Volume 16-33 VDC 16-33 FWR 16-33 V Pos Tone Setting 15cd 30cd 75cd 95cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 110ed 135cd 185cd DC FWR 1 Temporal High 98 115 158 173 182 212 266 136 153 188 206 228 258 304 80 80 2 Temporal 3 Low 98 102 141 162 173 202 255 150 150 176 194 216 242 280 76 76 3 Temporal 4_High 98 108 137 151 178 202 252 200 198 169 188 212 242 290 80 80 4 Temporal 4 Low 102 104 122 136 163 187 237 176 174 154 173 197 227 275 76 76 5 Continuous High 141 158 198 216 234 264 305 190 207 249 268 289 321 368 80 80 6 Continuous Low 120 128 179 196 215 244 1 285 165 182 226 244 266 297 342 76 76 UL Max.Low Frequency Sounder Current Draw(mA RMS) Current Draw Sound (mA) Output(dBA) Reverberant Volume 16--33 Volts 16-33 Volts Pos Tone Setting DC FWR DC FWR 1 Temporal High 108 150 80 80 2 Temporal Low 78 76 76 76 3 Temporal High 111 151 80 80 4 Temporal Low 80 76 76 76 5 Continuous High 111 151 80 80 6 Continuous Low 80 76 76 76 7 Coded High 1 111 1 151 1 80 1 80 8 Coded Low 1 80 1 76 1 76 1 76 'NOTE:For coded tones,temporal coding must be provided by the NAC. If the NAC voltage is held constant,the sounder output will remain constantly on.Coded ratings provided are for continuous voltage. A\m591 G-0'.•-Q-/2019•Page? L-Series Dimensions I.n Wall LF Sounder Strobe Wall LF Sounder � I - / 111 1 6'I06 t �0 i 000009 00D D0000000 0000 �` 000000 � e Ceiling LF Sounder Compact Wall LF Sounder Part No. Descriptlon Red White Low Frequency Sounder Strobes P2RL-LF P2WL-LF LF Sounder Strobe,Wall Low Frequency Sounders HRI:I.F HWI.-LF LF Sounder.Wall HGRL-LF HGWL-LF Compact LF Sounder,Wall HCRI:I_F HCWL:L_F LF Sounder,Ceiling Accessories MDL3R MDL3W Sync•CircuitTM Module, UL-listed SBBWL SBBWL Surface Mount Back Box,Wall SBBCRL SBBCWL Surface Mount Back Box,Ceiling SBBGRL SBBCWL Surface Mount Back Box,Wall,Compact System Senscre,-a a•egislared trademark and Syr•.c•C:rcwil-.s a trademark of,aney✓✓ell International,Inc. SYSTEM ©2�,9 Sys'�m 5ensnl. 3825 Ohio Avenue-St.Charles, IL 60174 Prod::.ctspenri�alions5,e;zcttr_chance,vitn„u'tner.-=,Visitsystemsersor.com SENSOR Phone: 800-SENSOR2•Fax:630-377-6495 nrcuvenlpioduai^formation,:1dud.gtheatestver,.onnttrnsdatasnze A`JG591 0-0'•1Cf1/2019 SYSTEM �4 SENSOR Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SPECTPA[ert SpectrAlert°Advance outdoor audible visible products A n v A N c WI are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to ILL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151'F. • Field-selectable candela settings: 15. 15/75,30.75,95, 110. 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes. 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings, including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SicxAUR® ®4 corrosion.Knock-outs located on the back eliminate the need to drill holes for screw-in mounting.Plastic and metal weatherproof back U` boxes come with`1/s-inch top and bottom conduit entries and'/a-inch F M MEA an,653187(cutom strobes) LISTED 7125-1e53138(no,,strobes: knock-outs at the back.Ascrew-in NPT plug with an 0-ring gasket 54011(chimes,horn drones,norrs) •�'�� a pproved crame strobes) S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-�.353189(horns,rh:m.w for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit"'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15. 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UI.1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature —40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Rangez 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 2.5-D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4XV x 1.3-D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7-L x 5.1­W x 2.0-D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S.PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AV DS01201. i UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RNIS).2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15175 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 86 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output candela ratings must be reduced in accordance with •8-17.5 15-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output(cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40°F 1 Terporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 68 88 93 92 100 100 95 70 5 Non- Medium 78 78 85 85 90 90 98 98 110 110 Temporal 115 115 6 Non- Low 75 75 81 81 86 84 96 92 135 135 Temporal 150 150 7' Coded High 82 82 88- 88 93 92 101 101 177 177 81 Coded Medium 78 78 65 85 90 90 97 98 185 185 91 Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8, and 9 are not available on 2-wire horn strobe. AVD501201 SpectrAlert Advance Diagrams 5.6` O 0 Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box up v Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK*1 2-Wire Horn Strobe,Standard cd.Red,Outdoor(includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK*' 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RK1 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes-plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK*t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK*t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK*' Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe,High cd,White, Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: *Add '-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for rise with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135.150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. SYSTEM sng Pm Sensci. 3825 Ohio Avenue•St.Charles, IL 60174 F,�.d���s�=e��e�:���s.���eiee:peera��e r,euce,vis tsYS;emzersor.e,T SENSOR Phone:800-SENSOR2•Fax:630-377-6495 ueertpredurticfor alion,DS012 1-3/1leeAveranc:hBdalas,heel. AVnJ'G13C:•3l12 Fire Alarm Accessories 9fireworX Electromagnetic Fire Door Holders DH Series i Overview Standard Features FireworX Electromagnetic Door Holders are ruggedly constructed • Surface mount, semi-flush, flush,and floor mounted models and attractively designed.The housings are baked with a durable Chrome or brass finishes blend In with other door hardware polyester undercoating and are available in either a chrome or brass finish. • Low current draw The floor or wall section houses the electromagnet while the • AC/DC models contact plate attaches to the door.The contact plate has a shock . Completely silent operation 25 Lbf(111 N)nominal holding force absorbing nylon(swivel)ball which allows the plate to adjust to any door angle. Floor units are available in single-door or double-door • Adjustable, 360 degree swivel contact plate (back to back)versions.Wall units are available in flush or surface mounted versions. FireworX door holders should be installed wherever doors may be effectively used to confine smoke and fire, or where the release of a self-closing door from a remote location is desirable for other reasons.Always consult your local Authority Having Jurisdiction with any questions regarding a specific ap- plication. Fail-safe operation is an inherent feature of FireworX door holder-releases. If power fails, doors are released automatically but may be opened or closed manually at any time.All units are free of moving parts, are self-contained and require no maintenance. These door holder-releases have a holding force of approximately 15 to 25 Lbf(66 to 111 N).The device holds a door open while energized. When de-energized by a relay controlled by the fire alarm system or other switch,the door is released to a closed position, checking the spread of smoke and flames. Electromagnetic door holders should be used and installed in accordance with local Building Codes and Standards. Page Y of 4 :1 E>. ........ FX85001-0603 interlogix.com Noc In bc. .._... .., ,.r i:<=t cz< q;; :zt.... Issue 5 Surface Mount Back Box Dimensions Door Magnet 0 0 1 41 n \ 4 I u 7c mm t_ O 0 u z z.i�m iuw u Extension Rod Applications Catch Plate Assembly and Accessories oil ,o 2<4.m 1)H-FR: I_ Page 2 of 4 DATA -S H E E T FX85001-0603 Nol to be Used for {:;ur ose—s. Issues Extension Rod Applications Catch Plate Assembly and Accessories Voltage Reference I.—I.oW H—Hlgh _A (C+L.)Low Voltage�...�., i C L H Low Voltage ® \/ C L H IC-#L)Higfi O t i Voltage High Voltage Low%blta to High Voltage t• ❑L H C a H Performance Data Model Voltage DC/MA AC/MA Tenrdnals CON Ws kg.(Nominal) DHX'-1224 12V 30 30 C&L Single 35 15.9 24V 15 15 C&H Single 35 15.9 DHX*-24120 24V 15 15 C&L Single 35 15.9 120V — 15 C&H Single 35 15.9 DHFMt-1224 12V 60 60 C&L Double 35 15.9 24V 60 60 C&H Double 35 15.9 DHFMt-24120 24V 30 30 C&L Double 35 15.9 120V — 30 C&H Double 35 15.9 For all models,"X"represents either F(Flush Mount),FM(Floor Mount single-coil),R(Recessed),or S(Surface Mount). t For Floor Mount,double coil models. NOTE:Voltage supplied by a UL listed control panel c Page 3 of 4 DATA w 7.7 2- FX85001-0603 Fdoi to be use!for oistaHait€ora pur>31:ses, issue 5 s Ordering Information Model Desaripeon Case Qty Wall Mount DHR-1224C 12 or 24 V DCN AC,recess-mount,chrome,with 3"Extension Rod 20/case DHR-24120C 24 V DCN AC 120V AC, recess-mount,chrome,with 3"Extension 20/case Rod DHF-1224C 12 or 24 V DCN AC,semi-flush-mount,chrome 20/case DHF-1224B 12 or 24 V DC/V AC,semi-flush-mount, brass 20/case DHF-24120B 24 V DCN AC 120V AC,recess-mount,chrome 20/case DHF-2410B 24 V DCN AC 120V AC,semi-flush-mount,brass 20/case DHS-1224C 12 or 24V DCN AC,surface-mount,chrome 20/case DHS-1224B 12 or 24V DCN AC,surface-mount,brass 20/case DHS-24120C 24V DCN AC 120V AC,surface-mount,chrome 20/case DHS-24120E 24V DCN AC 120V AC,surface-mount,brass 20/case Floor Mount DHFM1-1224 Single coil,12 or 24VDCNAC,floor-mount,brushed steel 6/case DHFM1-24120 Single coil,24VDCNAC 120VAC,floor-mount,brushed steel 6/case DHFM2-1224 Double coil, 12 or 24VDCNAC,floor-mount, brushed steel 6/case DHFM2-24120 Double coil,24VDCNAC 120VAC,floor-mount,brushed steel 6/'case Extension Rods DH-ER1 C 1"chrome DH-ER1B 1"brass DH-ER3C 3"chrome DH-ER3B 3"brass Accessories DHW Extension rod wrenches DH-BP Back Plate(chrome or brass) North America DH-ARMC Replacement armature,chrome T 885-286-8889 DH-ARMB Replacement armature,brass Asia T 852-2907-8106 F 852-2142-5063 Australia T 61-3-9239-1200 F 61-3-9239-1299 Europe T 32-2-725-11-20 F 32-2-721-40-47 Latin America T 561-998-6100 F 561-994-6572 interlogix interlogix.com L Specifications subject to change without notice. ©2012 Intedogix. All rights reserved. 0 iv _.T � H -T Page 4 of 4 FX85001-0603 N 1<.:>f ;;. t,£ir3 issue 5 �1Y FIRE ALARM PERMIT APPLICATION y�l IfN1OG Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •WA 98223 • Phone (360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO, INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS, (POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) _'E] New Fire Alarm ❑ Fire Alarm Alteration/Addition Project Address: I woo _4#--%0Xe4 POWs Parcel ID#: Number of Zones/Panels: Building Area(Sq Ft): IH:Wy S•F- Valuation: le+i'KTP 9� Owner: G.iZANbJ1s'rJ Ab(L4H LL.C. Phone Number: 360 435' -71-71 Address: fir` 15 City: A61-1-1Nc3oN State: WA Zip Code: 9cmZ3 Contact Person: 3tF� 1�Le�5INOV Phone Number: 42S 24`f W(4 S' Cell Phone: Email: _f-FF P, Boi AF(R.t. Ccr—, Address: Po �x 37 1 City: State: WA Zip Code 6jib 27-3 Contractor: S 4 N FIRE An)p SCc_%�rlry U Phone Number: qZ< 7,H44 I'fN 5" Address Pto Box 3711 City: A2LIr.1�.�°� State: % 'A � Zip Code: '9162z3 Contractor's License Number: $µr-tQHfg4zVkJ Expiration:--;Zo LZ Contact Person: L�(2 S5py go Email: 8N M—I>R.1=•wY—, Electrical Contractor: H T-ine P&x> MwQrj LLL Phone Number: 42-< 2NL1 l4L/S Address: Tn &7y% .3'7 1l City: Aorta.,PQLJG YJ State: W 6 Zip Code: Contractor's License Number: 1 f ISL�j F 12K-vJ Expiration: 19 I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws, rules and regulations of the State of Washington. Z� ���/ -7l Lf z.�zo Applicants Signature date �EPF �3Flcr��� Print Applicants Name FOR STAFF USE ONLY JUL 0 7 2020 Permit# Accepted By Amount Received Receipt# Date Received WEB Form-130 Page 1 of 1 6/16LP OUTDOOR PATIO N m33 M p EOL ...: xP�a Ixd mz= m ozu d6�a n DINING HALL REC.AREA 13, B U A v 10 FACP T 2 � A P H82 AIM F FACP AIM lAll INFO FICE FE$ 1 d p -' CHAIR STORAGE 101ID 102 _ ? B F132 B 1x0 IScd DESIGNER: �B EOL HBl-1 SVR30ctl B all$I O WaMEN O O O J D GNER. M,NE 107 �. � Ixd o Nc.E JEFF BROSSARD 39 , 6 H 1- RM P TAR BREAK FM. glE ,xa TO FA P 4i Ixd B B / lxdNICET LEVEL 3 ID#148093 5cd� M E ? H13� B H62 3 e LICENSE: HBl-3 A B 2 uP ELEcJ &;^� a 5ctl DO� o e4E B 1xd OMEN BROSSJ8951L7 7xa ouEcn^ DOE C a OUB E M AM/P i B 4c B 42 4 B 145 REFERENCE: 105w B 1`+� LF °.Ixd LF B LF lF B LFLF WI D B lsca lxa 30t0 B " A H A Mca \Ixa ��I� Ea © 2015IFC AND 2016 NFPA 72 100 B o o N d I AIM �. _ ORS A '. B' A B B ? A 1&d B NAC 1 ��� p O ? G ? ? O; C e A ? B A ? B lxd B Ixd A B 29 Ixd Ixd A / B i \I LF v J LF ❑❑ ui :. CLOSET ` N� ❑ f 8 le,, -. o, i �V2C txd HB1-4 _1YB 1xe B 15cd B LF g 1 m 0 1 p g B ? /1xa -1xa\ ? E B C ^I A ? B e txd B B' xa Z CV GROUP ROOM ..Ixa B it3 COONS OR STORAGE LP..4"RY H62-4 0 o; N M H Cu-%l LIBRARY I; WOMEN WOMEN WOMEN Q WOMEN HF, M1 r B D11 Orr t 727 SA1 .NARY CRAFT ROOM 13E �. M NTLP n 124 -Tlny DOUBLE 15ctl G J�'E DOUBLE b,Ixd Doygg L- �L�r. 11 ^ I �3 ;o Ixd 135 ANN 146 S7 '.'. 148 149 00 °'r- txd xd �� J �0— �r o 1 H82-1 4 30ca z `Fc I MEN O O I�1 B A ;o,Ixd _- k MEN B DOUBLE C _.. W—55 C- DOUBLE ,o, LF 156 I� SUPER. r� .—� ,.�........ 123 NIC 122 � 151 LF Ixa TO FACP .- _....,,._._- uj O V B B > d Z o, 01kd B 150d B ? p 7SWB Pam. ...�.. B ? ,� O O W '^ B v' G... ��// •�,, lxd 0 1 o; CORRIDOR i Ixd 0 1g Ixd p; o,Ixd B B O U O GROUP ROOM COUNSE 727 -7 B \�/ Ixd W 114 B ' .. O OFFS A B % 4\ LV vJ Z MEN MEN 7 0 ,OUBLE LF A fA DOUBLE Z 0 30ce �� 152 ,57 Itt B <t z c EOL o 30cd B GROUP R00M ,d ;o, EOL - GROUP ROOM 156 ISFA ? lxd 120 ' J Q MEN MEN O COUNSELOR COONS=LOR DOUBLE DOUBLE OFFICE B Oh:CE 153 1ISB it7 9 LF ? LF B o 150 B 8 OFFICE COPY ,..� .,. � �. _-� �i ISSUES . i�I I B o 15cd /UU._ \ Ixd o B J REV DATE DESCRIPTION I p A �� plxd ( Cd2I'OF ARLINGTON - `' BUILDING DEPARTMENT - MEN 8... B B DOUBLE �A/PP OVED DOUBLE 754 DATE LF .,/1lie. 2 y 154 LF NO CHANpES AV940RRED UNLESS APPROVED 8Y ih+E TITLE: B B BUILDING IIq_SPECTOR ? FIRE ALARM SIMEN lF B LF SINGLEN E PLAN 155 1 8 160 Ixd ,o; p• EOL I� n�Pry YcC� 5 EOL I d' EOL II Y �<i. 7-Iv- pap DATE: JULY 6,2020 PROJECT NO.: g 20-023 Received SHEET: 191 JUL FIRE ALARM PLAN ���J3oti FA- 1 SCALE:1/8"=1'-0" 0 4' 8' 16' � d r rn n A SCALE: 1/8"=1'-0" 0 m N m3a n 2=N N mzm d¢�o- EQUIPMENT LEGEND _ DEVICE QUANTITY PART NUMBER DESCRIPTION B4CKBOX LF Ixd Ixd LF LF 1xa Ixd LF SYMBOL - p, _ SILENT KNIGHT FIRE ALARM CONTROL � _ EOL FRCP 1 SK-6700 PANEL INCLUDED - _ B - LF txtl Ixd LF LF Ixd txd LF LF Ixd Ixd LF _ HB 2 SK-5495 SILENT KNIGHT HORN BOOSTER INCLUDED ,o, o p, o o, •d H82-3 EOL - - qNN i SK-5860 SILENT KNIGHT LCD REMOTE INCLUDED B ANNUNCIATOR ISctl LF LF txd ixd LF LF Ixd Ixd LF HB2-2 Q 16 SK-PHOTO-W SILENT KNIGHT SMOKE DETECTOR 4 SQUARE X 1-7/8'DEEP -' EOL B © 1 SK-PU�f d SILENT KNIGHT MANUAL PULL STATION SINGLE GANG ixd LF LF txtl Ixd LF Li Ixd Ixd LF HB2-1 Eq. o 0 0 ,o p; ©o,/ 40 8K-SWL SPECTRA ALERT WALL MOUNT 4 SQUARE%1-7/8"DEEP STROBE B SPECTRA ALERT WALL MOUNT Ixd 30ctl txd JOIN Ixd Ixd ixd �o;/ 23 BK-P2WL HORN STROBE 4 SQUARE%1-7/8'DEEP Ixd Ixtl Ix0 lxd H 6 1-4 EDL ,o, ;o; p, 'o; o, SPECTRA ALERT WALL MOUNT LOW DESIGNER: LF Do 20 HWL-LF FREQUENCY SOUNDER 4 SQUARE%1-7/8"DEEP JEFF BROSSARD B NICET LEVEL 3 ID It 148093 txa 7Dcd Ixd Ixd txa txd Ixd t5cd 30cd ® 1 -- WATER-FLOW CONNECTION(•) PROVIDED BY OTHERS - LICENSE: EOL 'o o ;o; o, o ;d, b, p, ;o; H81-3 B TAMPER CONNECTION(•) PROVIDED BY OTHERS BROSSJB951 L7 3Dce 1xa Ixd 15ctl Ixd wed JOcd Ixd 1xa Ixd 2 2 ? REFERENCE: H81-2 DH 1 DHX-1224 GE FIREWORX DOOR HOLDER 4 SQUARE X 1-7/8'DEEP EOL p, o p, p pp, 2015 IFC AND 2016 NFPA 72 B 1 -- HOOD DEFECTOR(") PROVIDED BY OTHERS 15cd Ixd 7 d Ixd 151d 15cd Iscd Ixd Ixd HBI-1 2 2 2 ? 2 2 2 2 EOL qo, p; p, p o, Lo,' 1 BK-P2RK SPECTRA LERTSWEATHERPROOF 4 SQUARE X 1-7/8"DEEP TROBE Ixd txd lxd ixd NAC 1 I I I I ( 2 p AIM AIM ? ? AIM 2 AiM 3 SK-MONITOR SILENT KNIGHT ADDRESSABLE q SQUARE%1-7/8"DEEP ui EOL 'd p; ;o; 'o' A INPUT MODULE 75 H00 � C) B CV B Z IIII IIII pNN (•) PROVIDED AND INSTALLED BY OTHERS /W C) QO C ------ EXISTING DEVICE TO REMAIN U J 0) TO 120 VAC UNSWITCHED B B m z DEDICATED CIRCUIT FACP H81 HB2 NEW OR EXISTING DEVICE RELOCATED O TO TELCO ROOM / INDICATES CANDELA ryo Z I— '� FIRST FLOOR Z FIRST FLOOR - a (E) INDICATES EXISTING w a c INDICATES CEILING MOUNT FIRE ALARM ONE-LINE RISER DIAGRAM C0 uj Q SCALE:NONE v LLj /0 3:rro U) O Z O SEQUENCE OF OPERATIONS DESIGNED AUDIBILITY LEVEL PER WIRE LEGEND C J OCCUPANCY CLASSIFICATION G < 4 a Z GROUP A 70db TYPE DESCRIPTION w <_ ID Or A 18 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE z z< a z v ¢ GROUP B 70db O > >u Z `�r a z z B 14 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE O ? a N < < z O i 0 GROUP E 60db a << m? O z ID 7,G O G C 18 AWG, 4 CONDUCTOR 'FPLR' JACKETED CABLE u u z LL r z "'a GROUP F 95db z z8 m zz 2Q m� W z u z 2 L9 a u ¢ O rz GROUP M 55db aLL air �a 3° aG �u v�iu ISSUES WATERFLOW DEVICE X X X X TAMPER DEVICE X X X GROUP R 50db GENERAL NOTES: REV DATE DESCRIPTION CROUP S 45db 1. ALL WORK IS TO CONFORM TO NATIONAL ELECTRIC CODE STANDARDS. BUILDING PULL STATION X X X X 2. WIRING METHOD IS TO BE OPEN CABLING EXCEPT WHERE IT IS EXPOSED AND BELOW SEVEN FEET - THEN IT IS TO BE IN CONDUIT. BUILDING SMOKE DETECTOR X X X X 3. ALL JUNCTION BOXES, COVERS,AND BACK BOXES ARE TO BE PAINTED RED. AC POWER LOSS X X X 4. PULL STATIONS ARE TO BE MOUNTED AT 48"TO 53"ABOVE THE FLOOR. TITLE: LOW BATTERY X X X 5. ALL WALL MOUNT INDOOR HORNS,STROBES, HORN STROBES,AND SPEAKER STROBES ARE TO BE MOUNTED 80" FIRE ALARM ABOVE THE FLOOR OR 6"BELOW THE CEILING,WHICHEVER IS LOWER. LEGENDS, NOTES 6. SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING: AND RISER A) 36"INCHES AWAY FROM ANY AIR HANDLING SYSTEM DIFFUSER t 8) NOT IN CLOSE PROXIMITY TO ANY FLUORESCENT LIGHT FIXTURES DIAGRAM 7. EXTERIOR HORN/STROBE SHALL BE MOUNTED ON THE TOP 2/3 OF THE OUTSIDE WALL OF THE BUILDING,AS HIGH AS POSSIBLE FOR MAXIMUM VISIBILITY FROM THE FIRE DEPARTMENT ACCESS ROADWAY. DATE: a 8. ALL WIRING PENETRATING ANY FIRE RATED BARRIER SHALL BE SEALED WITH MATERIAL WHICH WILL PREVENT PASSAGE JULY 6,2020 i OF FLAME AND HOT GASES. PROJECT NO.: w 20-023 R SHEET: s FA-2 i CITY OF ARLINGTON I 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3=417-Pennnit Center:360-403-3551 BUILDING PERAHT 16415 Smokey Point Blvd Permit#:3302 Permit Expiration Date: 0111061/2021 Parcel#:3 1 05280020 1500 Valuation: 19250.00 OWNER APPLICANT CONTRACTOR RGB LLC B&H Fire and Security LLC B&H Fire and Security, LLC 220 146TH PLACE SE PO Box 3711 PO Box 3711 MILL CREEK,WA 98012 Arlington,WA 98223 Arlington,WA 9S223 425-244-1445 425-244-1445 LIC:B[IF[RHF842KW EXP:O5i 1612022 NIECHAIYICAL CONTRACTOR PLUTMBING CONTRACTOR LIC#: EXP LIC#: EXP: JOB DESCRIIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2015 STORIES: I CON'ST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: I OCC LOAD: PERNIIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City, of any state or federal law,or of any order,proclamation,guidance advice or decision oC the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid."fhe building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order_state or federal law,or any order,proclamation,guidance:or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOTING THE HE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATT_ OF INASHINGTON RELATING TO WORKMEN'S CO,NIPENSATION INSURANCE.AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING; OFFICIAL OR HIS.;TIER DFPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL,TO USE OR OCCUPY A BUILDfNCI OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED, IBC l I()1TRC 1 10. SALES TAX NOTICE.Sales tax relating to construction and construction materials in the City of Arlington mast be reporwd on your sales tax return form and coded City oCArlington#3101. t Signature Print Name Date ROCaScct By CONDITIONS 1. Permit and set of approved plans to remain on site during installation_ Installers shall present NICET II certification upon request.2.Battery load test required_switch F,ACP and Power Modules(and communicator/dialer if"provided with a battery back- up)to battery operation 24-hours .r to final inspection.Notification appliances to opt....ic for 5 minutes on battery power.3. Trouble condition to be verified for initiation,notification and signaling circuits.4.Smoke detectors installed in corridors 129 and 130 shall not exceed 30 foot spacing.5. Strobe coverage in morns 121, 122 and135 are too far off of wall as indicated on plans. Ensure that proper spacing is observed per cd rating of devices per NFPA 72.b.Manual pull stations shall be dual action.7. Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFP.4 requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2).8.Record of completion form shall be submitted prior to project close-out. 9.Adhere to approved plans. 10.Approved job copy shall be onsite for installation and inspections. 11.Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK'1'0 BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PEU41SSION. PERMIT FEES Date Description 09121/2020 Fire Alarm System Permit Fee Amount 09/21/2020 Processing/Technology Fee $475.00 09/21/2020 Fire System Plan Review $25.00 09/21/2020 FACP/Transmitter $312.71 $200.00 Total Due: $1,012.71 Total Payment: $0.00 Balance Due: $1,012.71 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon ° OF CITY ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT Permit#:3302 16415 Smokey Point Blvd Permit Expiration Date: 01/06/2021 Parcel#: 31052800201500 Valuation: 19250.00 OWNER APPLICANT CONTRACTOR RGB LLC B&H Fire and Security LLC B&H Fire and Security,LLC 220 146TH PLACE SE PO Box 3711 PO Box 3711 MILL CREEK,WA 98012 Arlington,WA 98223 Arlington,WA 98223 425-244-1445 425-244-1445 LIC:BHFIRHF842KW EXP:05/16/2022 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: 4� JOB DESCRIPTION _7 PERMIT TYPE: Fire Alarm CODE YEAR: 2015 STORIES: I CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: 1 OCC LOAD: ENEEL PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City, of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law, or of any order,proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law, or any order,proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 1 l0/1RC l I0. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By D& CONDITIONS 1. Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request. 2.Battery load test required,switch FACP and Power Modules(and communicator/dialer if provided with a battery back- up)to battery operation 24-hours prior to final inspection.Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for initiation,notification and signaling circuits.4. Smoke detectors installed in corridors 129 and 150 shall not exceed 30 foot spacing. 5. Strobe coverage in rooms 121, 122 and135 are too far off of wall as indicated on plans. Ensure that proper spacing is observed per cd rating of devices per NFPA 72. 6.Manual pull stations shall be dual action. 7. Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). 8.Record of completion form shall be submitted prior to project close-out. 9.Adhere to approved plans. 10.Approved job copy shall be onsite for installation and inspections. 11.Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/21/2020 Fire Alarm System Permit $475.00 09/21/2020 Processing/Technology Fee $25.00 09/21/2020 Fire System Plan Review $312.71 09/21/2020 FACP/Transmitter $200.00 Total Due: $1,012.71 Total Payment: $0.00 Balance Due: $1,012.71 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Date: 03/30/2026 Permit#: 3302 Permit 07/10/2020 Date: Review 07/10/2020 Date: Permit FIRE ALARM Type: Review FIRE ALARM Type: Target Date: 07/24/2020 Scheduled 00:00 Time: Completed 07/14/2020 Date: Description: 1. Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request. 2. Battery load test required, switch FACP and Power Modules (and communicator/dialer if provided with a battery back-up) to battery operation 24- hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for initiation, notification and signaling circuits. 4. Smoke detectors installed in corridors 129 and 150 shall not exceed 30 foot spacing. 5. Strobe coverage in rooms 121, 122 and 135 are too far off of wall as indicated on plans. Ensure that proper spacing is observed per cd rating of devices per NFPA 72. 6. Manual pull stations shall be dual action. 7. Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection (NFPA 72 Section 7.5.2). 8. Record of completion form shall be submitted prior to project close- out. Review Status: Assigned FIRE To: Time In: 00:00 Time Out: 00:00 Hours: 2.5 Notes 07/27/2020 1. Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request. 2. Battery load test required, switch FACP and Power Modules (and communicator/dialer if provided with a battery back-up)to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for initiation, notification and signaling circuits. 4. Smoke detectors installed in corridors 129 and 150 shall not exceed 30 foot spacing. 5. Strobe coverage in rooms 121, 122 and135 are too far off of wall as indicated on plans. Ensure that proper spacing is observed per cd rating of devices per NFPA 72. 6. Manual pull stations shall be dual action. 7. Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). 8. Record of completion form shall be submitted prior to project close-out. Property Information Parcel#: 31052800201500 RGB LLC RGB LLC 220 146TH PLACE SE 16415 Smokey Point Blvd. MILL CREEK, WA 98012 Zoning: 910 UNDEVELOPED (VACANT) LANDLot: Block: Permit#: 3302 Permit Date: 07/10/20 Permit Type: FIRE ALARM Project Name: Holman Recovery Center Applicant Name: B&H Fire and Security LLC Applicant Address: PO Box 3711 Applicant, City, State, Zip: Arlington,WA 98223 Contact: Jeff Brossard Phone: 425-244-1445 Email:jeff@bnhfire.com Scope of Work: New Fire Alarm Valuation: 19250.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 12/08/2020 Permit Expires: 06/06/2021 Form Permit Type: Status: LASERFICHE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 910 31052800201500 16415 Smokey Point Blvd. RGB LLC UNDEVELOPED (VACANT)LAND Contractors Contractor Primary Contact Phone Address Contractor Type License License# B&H FIRE AND JEFF BROSSARD 425-244-1445 PO BOX 3711 ELECTRICAL COA 603 612 112 SECURITY LLC CONTRACTOR B&H FIRE AND JEFF BROSSARD 425-244-1445 PO BOX 3711 ELECTRICAL LABOR&BHFIRHF842KW SECURITY LLC CONTRACTOR INDUSTRIES Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status Fire Alarm System Partly R20.ACCESSORY Approved.All devices and 12/07/2021 STRUCTURE announcing appliances 12/03/2021 12/03/2021 Partial FINAL tested for TCO.Kitchen Approval Hood still needs to be connected. Plan Reviews Date Review Type Description Assigned To Review Status 07/10/2020 FIRE ALARM BUILDING 1.Permit and set of approved plans to remain on site during installation.Installers shall present NICET II certification upon request. 2.Battery load test required,switch FACP and Power Modules(and communicator/dialer if provided with a battery back-up)to battery operation 24-hours prior to final inspection.Notification appliances to operate for 5 minutes on battery power. 3.Trouble condition to be verified for initiation, notification and signaling circuits. 4.Smoke detectors installed in corridors 129 and 150 shall 07/10/2020 FIRE ALARM not exceed 30 foot spacing. FIRE 5.Strobe coverage in rooms 121, 122 and135 are too far off of wall as indicated on plans.Ensure that proper spacing is observed per cd rating of devices per NFPA 72. 6.Manual pull stations shall be dual action. 7.Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). 8.Record of completion form shall be submitted prior to project close-out. Fees Fee Description Notes Amount Fire Alarm System Permit NFPA 72- 105.7.3 $475.00 Processing/Technology $25.00 Fire System Plan Review Table 4-1 $312.71 FACP/Transmitter-New $200.00 Credit Card Service $30.38 Total $1,043.09 Attached Letters Date Letter Description 07/10/2020 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 12/08/2020 Tina Herdt 83823303 $1,012.71 12/08/2020 83823303 Raelynn Jones $30.38 Outstanding Balance $0.00 Notes Date Note Created By: 07/27/2020 Don't issue until the building submittal has been received,reviewed and approved. Kristin Foster 1.Permit and set of approved plans to remain on site during installation.Installers shall present NICET II certification upon request. 2.Battery load test required,switch FACP and Power Modules(and communicator/dialer if provided with a battery back-up)to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3.Trouble condition to be verified for initiation,notification and signaling circuits. 4.Smoke detectors installed in corridors 129 and 150 shall not exceed 30 foot spacing. 07/27/2020 5.Strobe coverage in rooms 121, 122 and135 are too far off of wall as indicated on plans. Kristin Foster Ensure that proper spacing is observed per cd rating of devices per NFPA 72. 6.Manual pull stations shall be dual action. 7.Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). 8.Record of completion form shall be submitted prior to project close-out. Uploaded Files Date File Name 01/27/2022 10616431-3302 Approved Plans.pdf 03/23/2021 8390861-3302 Issued Permit.pdf 07/10/2020 6958851-3302 Apnlication.pdf OUTDOOR PATIO N N 00 3 ppN '••I W EO u=m:3 DINING HALL REC.AREA Zz A N v TO P FACP A XB2 r 2 HBt AIM FACP 'w aM TS ryl— INO F CE COPY 101 102 1 d p CHAIR STORAGE B j B ❑ Ixd Ixd _ 0 o L ° -------'-'— — .. — �. , B .._. EOL L,J]HBI-t Ste. Joee B` � g 1 �p5ed . WSNGLE �j .. DESIGNER: %AM M S 1D7 ° HW" a1 JEFF BROSSARD u ibcd 139�1—' 0 Ixd B /B Ixd NICET LEVEL 3 ID#148093 B 1 od 6 HBT-2 RM PATIENT T ; EMPBREAOYRM. g KI HE _iINF.,S� TO FACP HB2-3 B B ° LICENSE: it 109 110 111 130 1JS B WOMEN WOMEN xd WOMEN WOMEN o WOMEN BROSSJB951 L7 HBI-3 A 75cd - A IA L= C E%AM -- B = -- SING DDU�LE B DOUBLE 00 UBLE Ixd DOUBLE M �A - 108 I B STRDU�_ _ 14D B lag 143 B B 145 REFERENCE: WAITING A H B- LF LF LF 15ed rl LF B LF - LF B �❑ 2015 IFC AND 2016 NFPA 72 ..-.. �j fin/ ' 100 B Ixd 15Cd �t0 B A AM A 30cd lxd '� �] EOL B O A ..CORRIDO A B 0• A O B A Ixd B CCRI2IDQF B A 'z B Ixd 15cd e B t29 15ed 2 Ixd A NAC 1 15o� B B •T— ___ I ..... B - =--.-.—.-- _ A _ (/ � Eq. I'�F 0_OUP III JihT Ixd �����• •o B LF LF LF �❑ ui B .o, 1� °• ROOM_ B 15Cd B 2 _ B B lxd S B Ixq 7 CN 1x B xd 113 COUNS OR 4--°-- . STORAGE A Y A H62-4 o o Z N M},gl M.H.COUNS. - LIBRARY ' N W M N MEN FFI O MO�InTOR pJ000B E 1� WOMEN E WOMEN BLE 1,� WOMEN — _ Y CRAFT ROOM 136 " �---- o txd 135 137 a1X 146 -- 147 lag 149 ' ` J Txd o 1xa V � 103 �ioa7 JDed o,Ixd 12a OF CE J 127 —.A 1� 2�-�- _ - ----r -- -.HB2-1. B HBY-2 m MEN (� -, z A 0 1 d MEN B DOUBLE C L, .... _ --.--.�. .,:� -r -.___.-_ _. ~ O B WOMEN CLINIC EIR. DOUBLE 156 Z - 123 122 1 151 LF Ixd o, LF TO FACP p JOtd B Ixd O L � °• — Ixd g o R txd r L" —� 0 B 2 D 0w Ixd Ixd o B r , GROUP RODM B Ixd fl8 B EXECUTIVE OR 0 1xtl°. ... B _ �/ A B �J 1 / 1xd C) Vw COUNFDIRECTOR R 121 Z 11 I \ B ° _—. _.. MEN LF A nM�119UE O J �d IQ.QLE LF 157 z \ B Eq- °. 30cd B B J fRpUP ROOM o o EOL GROUP ROOM - 116 Ixd ? txd 120 J COUNSELOR COUNSELOR MEN DOUR,F auwlEO FI B FO FICE l I53 f56 9 LF LF B o Ixd OFFICE COPY \--/ 0 V1 Fr 0 ISSUES aXx� Ixd?• REV DATE DESCRIPTION 0 1 B d Ixd A plxd 0 (CITY OF ARLINGT'ON BUILDING DEPARTMENE MEN MEN B B OSJl9LE ATE DOUBLE B r159 4A 154 LF /LF N0 CHANGES AUTHORIZED UNLESS APPROVED BY THIS TITLE: B B - BUILDING 1105PECTOR ? FIRE ALARM MEN B MEN PLAN 51NA E LF LF sidu 155� B 160 ° 150d 0 ° Eq. V,cc E Eq. I _.... Do DATE: ll r rl, s JULY 6,2020 PROJECT NO.: 20-023 r Received SHEET: f I.LI.] JUL 0.a 2020 FIRE ALARM PLAN kt)Vol- FA- 1 SCALE:1/8"=1'-O" 0 4' 8' 16' a � SCALE: 1/8"s1'-0" 10 N m3� x N °ma=a :3 co ad° :a EQUIPMENT LEGEND LF ISce IScd LF LF lktl IScd LF OEVK;E SYMBOL QUANTITY PART NUMBER DESCRIPTION BACKBOX a r•-i I� HB2-4 SILENT KNIGHT FIRE ALARM CONTROL EOL R FACP t SK-6700 PANEL INCLUDED B LF HB 2 SK-5495 SILENT KNIGHT HORN BOOSTER INCLUDED LF Ikd Iktl LF LF Ikd lkd LF V lxa Ixa LF HB2-3 EOL SILENT KNIGHT LCD REMOTE p pNN 1 SK-5860 ANNUNCIATOR INCLUDED F B y 15ca LF LF ka 15cd LF LF xa 15cd LF HB2-2 © 16 SK-PHOTO-W SILENT KNIGHT SMOKE DETECTOR 4 SQUARE X 1-7/8"DEEP W EOL ° ° e © 1 SK-PLg ' SILENT KNIGHT MANUAL PULL STATION SINGLE GANG IScd LF LF Ixd tkd LF LF Iktl 1xtl LF HB2-1 rn EOL °. ;o; p; o; Coo 40 BK-SWL SPECTRA ALERT WALL MOUNT 4 SQUARE X 1-7/8"DEEP STROBE 7xd rota I d JOea xe kd xa B SPECTRA ALERT WALL MOUNT Lfl1 23 BK-P2WL . xd xd xd xd HB1_4 HORN STROBE <SQUARE X 1-7/8 DEEP EDL ° 'O 0, G LFP❑ 20 HWL-LF SPECTRA ALERT WALL MOUNT LOW 4 SQUARE%1-7/8"DEEP DESIGNER: FREQUENCY SOUNDER JEFF BROSSARD B NICET LEVEL 3 ID#148093 15ed 3ood Ikd Ikd Ikd Ikd Ixd IScd 30cd HBi-3 L"J 1 -- WATER-FLOW CONNECTION(•) PROVIDED BY OTHERS EOL °. 0, O, O; 0, O, O, LICENSE: TAMPER CONNECTION(•) PROVIDED BY OTHERS BROSSJB951L7 3octl lxe lkd coed SOce lxd ? 2 REFERENCE: Ikd ikd Ikd Ixtl HB1-2 ? 2 1 EOL DHX-1224 GE FIREWORX DOOR HOLDER 4 SQUARE X 1-7/8-DEEP 2015 IFC AND 2016 NFPA 72 P, o ,o, p; A, A, o o, p, O B 7 d Ikd lkd Ikd Ikd Ikd HB1_1 2 ? 2 2 ? 2 ? 2 Ram1 -- HOOD DETECTOR(•) PROVIDED BY OTHERS Ikd tk0 7 d EOL P. o, ;o, p, o, p, p, p o, ° 1 BK-P2RK SPECTRA ALERTS TROBE WEATHERPROOF 4 SQUARE X 1-7/B-DEEP HORNB SILENT KNIGHT ADDRESSABLE Ike Ikd lkd Ikd , 1 I I I I I I I ? p AIM AIM ? ? AIM ? AIN 3 SK-MONITOR INPUT MODULE 4 SQUARE X 1-7/8"DEEP F 15 HOOD DH B B p N N PROVIDED z AND INSTALLED BY OTHERS W TO 120 VAC UNSWITCHED C -- EXISTING DEVICE TO REMAIN U J O) DEDICATED CIRCUIT B B NEW OR EXISTING DEVICE RELOCATED m Z TO TELCO ROOM FACP HB1 HB2 INDICATES CANDELA ~ FIRST FLOOR FIRST FLOOR � z O (E) INDICATES EXISTING W O Z C INDICATES CEILING MOUNT > a FIRE ALARM ONE-LINE RISER DIAGRAM O w C= SCALE:NONE U /W z o � DESIGNED AUDIBILITY LEVEL PER IIISEQUENCE OF OPERATIONS WIRE LEGEND _z v} OCCUPANCY CLASSIFICATION � � p z GROUP A 70db TYPE DESCRIPTION J W 5 ( A 18 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE °z °z a g o o GROUP B 70db O z z= z g a 0 z c7 z B 14 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE mLD 4 a 9 a¢¢fin Q z o 11 0 GROUP E 60db a 0 a tl1 g �' y+�' GROUP F 9500 C 18 AWG, 4 CONDUCTOR 'FPLR' JACKETED CABLE zW z a z m a U a 'o a GROUP M 55db a LL az �a 3O ISSUES WATERFLOW DEVICE X X X X GROUP R 50db GENERAL NOTES: REV DATE DESCRIPTION TAMPER DEVICE X X % GROUP S 45db 1. ALL WORK IS TO CONFORM TO NATIONAL ELECTRIC CODE STANDARDS. BUILDING PULL STATION X X % X 2, WIRING METHOD IS TO BE OPEN CABLING EXCEPT WHERE IT IS EXPOSED AND BELOW SEVEN FEET - THEN IT IS TO BE IN CONDUIT. BUILDING SMOKE DETECTOR X X X X 3, ALL JUNCTION BOXES, COVERS,AND BACK BOXES ARE TO BE PAINTED RED. AC POWER LOSS X X X 4, PULL STATIONS ARE TO BE MOUNTED AT 48"TO 53"ABOVE THE FLOOR. TITLE: LOW BATTERY X X X 5. ALL WALL MOUNT INDOOR HORNS, STROBES, HORN STROBES,AND SPEAKER STROBES ARE TO BE MOUNTED BO" FIRE ALARM ABOVE THE FLOOR OR 6"BELOW THE CEILING,WHICHEVER IS LOWER, LEGENDS, NOTES 6, SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING: AND RISER A) 36"INCHES AWAY FROM ANY AIR HANDLING SYSTEM DIFFUSER a B) NOT IN CLOSE PROXIMITY TO ANY FLUORESCENT LIGHT FIXTURES DIAGRAM 7. EXTERIOR HORN/STROBE SHALL BE MOUNTED ON THE TOP 2/3 OF THE OUTSIDE WALL OF THE BUILDING,AS HIGH EEE AS POSSIBLE FOR MAXIMUM VISIBILITY FROM THE FIRE DEPARTMENT ACCESS ROADWAY. DATE: 8. ALL WIRING PENETRATING ANY FIRE RATED BARRIER SHALL BE SEALED WITH MATERIAL WHICH WILL PREVENT PASSAGE JULY 6,2020 OF FLAME AND HOT GASES. $h PROJECT NO.: R 20-023 SHEET: g FA-2