HomeMy WebLinkAbout437 S Olympic Ave_BLD2831_2026 CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON,WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:437 S.Olympic Ave Permit#:2831 Parcel M 00411700701900 Valuation:.00 APPLICANT CONTRACTOR l Name:YOUNG HEIDI Name:Day and Nite Plumbing and Heating Name:Day&Nite Plumbing&Heating,Inc Address:437 SOUTH OLYMPIC AVE Address:16614 13th Ave W. Address: 16614 lath Ave W City,State Zip:ARLINGTON,WA 98223 City,State Zip:Lynnwood,WA 98037 City,State Zip:Lyunwood,WA 98037 Phone: Phone:425-775-6464 Phone:425-775-6464 LIC: EXP: MECAANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Day&Nite Plumbing and Heating Name: Address: 16614 130i Ave W Address: City,State,Zip:Lynnwood,WA 98037 City,State,Zip: Plione:425-775-6464 Phone: LIC#:DAYNIPH944RQ EXP: 01/01/2021 LIC#: EXP: PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORIC AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI l0/1RC1 I0. SALES'FAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form an d rlin on 43101. T� � Le 12 i .b(Rye /D'g•19 LIS'4�_Jnz 10/8/2019 Signature Print Name Date Re ascd Bl Date CONDITIONS Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMrr COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC,)WILL REQUIRE SEPARATE PERMISSION, Date Description Fee Amount 1 010 7/2 01 9 Furnace $25.00 10/07/2019 Mechanical Permit Base Fee $25.00 10/07/2019 Processing/Technology Fee $25.00 Total Due: $75.00 _ Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 2831 Permit Date: 10/07/19 Project Name: Young Site Address: 437 S. Olympic Ave Company Name: Day and Nite Plumbing and Heating Company Address: 16614 13th Ave W. City, State,Zip: Lynnwood, WA 98037 Contact: Phone: 425-775-6464 Email: bryan@dayandnite.net Permit Type: Residential Mechanical Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Type of Construction: Occupancy Type: Proposed Use: Replace gas furnace MIC/Opportunity Zone: Permit Issued: Permit Expires: Type of Construction-DNU: Status-DNU: Status: IN PROCESS Property Parcel# Address Legal Description Owner Name Owner Phone Zoning I I I Single Family 00411700701900 437 S OLYMPIC AVE YOUNG HEIDI Residence- Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# Day&Nite Plumbing& 16614 13th Ave Labor and Bryan Radcliff 425-775-6464 CONTRACTOR DAYNIPH944RQ Heating,Inc w Industries Fees Fee Description Notes Amount Furnace 322.10.00.00 $25.00 Mechanical Permit Base Fee 322.10.00.00 $25.00 Processing/Technology Fee 341.43.00.02 $25.00 Total $75.00 Notes Date Note Created By: 10/07/2019 Emailed contractor for business license Raelynn Jones Uploaded Files Date File Name 10/07/2019 5719425-attachments CO15031000017664944 LcMp3CL8jdSW Q2SkdJ Product+Date+Sheet,pdf 10107/2019 5719423-2831_A0 Iication•pd A. }� RESIDENTIAL MECHANICAL A 9 PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:437 S Olympic Ave Project Description:Replace existing gas furnace with new gas furnace in same location, no new gas Owner: Heidi Young Address: 437 S Olympic Ave City: Arlington State WA Zip Code: 98223 Phone: 425-293-9914 Email:heidi919@comcast.net Applicant: Day and Nite Plumbing and Heating Address: 16614 13th Ave W City: Lynnwood State WA Zip Code: 98037 Phone: 425-775-6464 Email: bryan@dayandnite.net CONTRACTOR INFORMATION Contractor Name:Day and Nite Plumbing and Heating Address: 16614 13th Ave W City Lynnwood State WA Zip Code: 98037 License Number:DAYNIPH944RQ Expiration: 01/01/21 Phone:425-775-6464 Email:bryan@dayandnite.net STAFF USE ONL Received Permit #: �� ���` Accepted by Dated�T 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL T.� PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #820TA36070V14 AFUE 80 ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER Freestanding Stove Fire Place Insert EJ Outdoor BBQ Gas Piping U,', Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: 4 Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: . .... Date 10/05/2019 Applicant Printed Name: Bryan Radcliff I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 Sizes 045 thrill 135 i t 4-Way Multipoise Induced Combustion (;as Furnace Product Data PERFORMANCE A ® ® • Perfect Heat®operation ® Two-stage heating even with single-stage thermostat-patented Q Adaptive Control Technology Reduced operating sound through low-stage operation and sound elimination combustion system • Two-stage heating with single-stage thermostat with r l patented Adaptive Control Technology ®�®� • Microprocessor based"smart"control center Fan on-Continuous Fan speed adjustable from thermostat Adjustable heating air temperature rise ' Adapts heating stages to meet demand Dehumidify mode Enhanced diagnostics with LED and reflective sight glass, non-volatile fault code memory,and self test feature On-board fuse for transformer protection • Perfect Light-Igniter • Patented blocked vent safeguard to ensure proper furnace venting • Insulated blower compartment I • Inner door for tighter sealing 9 • Variable-speed ECM blower motor Increased SEER ratings for AC and HP systems as compared to Al0252 the Air Conditioning Heating and Refrigeration Institute's THE TWO-STAGE GAS FURNACE standard coil-only rating when paired with selected Bryant The Two-stage,Variable-speed,4-way Multipoise Gas Furnace evaporator coils. offers outstanding comfort in an 80%AFUE furnace. Perfectly matches CFM to cooling system at all static points You get the benefits of Perfect Heat': reduced drafts, reduced . Noise elimination combustion system sound levels, longer cycles, less temperature swings between INSTALLATION FLEXIBILITY cycles,less temperature differences between rooms, and improved indoor air quality. Plus, it features a dehumidify mode and the • 4-way Multipoise fur•nace,13 vent applications ability to change continuous fan speeds from the thermostat.The . Compact design-only 33-1/3 in.(847 turn)tall 820TA/821TA furnaces are approved for use with natural or propane gas.821TA- Low NOx units are designed for California APPLICATIONS installations and meet 40 ng/J NOx emissions.Can be installed in • SrnartEvap' can lower the humidity level in the home by air quality management districts with a 40 ng/J NOx emissions nearly 10 percent requirement. • All models are Chimney friendly when used with accessary vent kit 1F a s t • • HYBRID HEAT®Dual Fuel System compatible CERTIFICATION cF rtc �® IS09001 • Cabinet airleakage less than 2.0%at 1.0 in.W.C.and cabinet air leakage less than 1.4%at 0.5 in.W.C.when tested in accordance with ASHRAE standard 193 am 1 • Residential installations eligible For consumer financing Use of IhcAHRI Certified TM Mark indicates a through the Retail Credit Program mmmfaclurer'spodicipationintheprogmm For verification ofcertificalion for individual products, go to www.aliddireclory.org. FURNACE COMPONENTS INDUCER MOTOR VENT ASSEMBLY ELBOW MAIN LIMIT SWITCH PRESSURE —--� — _ (BEHIND am VALVE) SWITCH o� BLOCKED VENT SWITCH FLUE COLLECTOR - BOX FLAME CAS VALVE _ I j SENSOR 41 U 0 MANUAL RESET — GAS MANIFOLD LIMIT SWITCHES o HOTSURFACE ran- 4. IGNITOR GAS BURNER BLOWER I�t DOOR SAFETY SWITCH o 0 FURNACE ` CONTROL BOARD i M BLOWERAND s MOTOR r+ Al 90086 NOTE: The furnaces are factory shipped for use with natural gas. These furnaces can be field-converted for propane gas with a factory-authorized and listed accessory conversion kit. EXAMPLE OF MODEL NUMBER NOMENCLATURE 1 2 3 4 5 0.7 8-10 11 12-13 14 15 10 Feet Molar Oodhp Voltepe Mmr EwlOW TIerINGX AFUEMDx HeelingBtspes Series Cepedly(CFK Hag Input Molar Type Wft 0*—) Un-used aeries 0 B 7 M B 42 0B0 0 17 A A � � C-Cum VatoGa 8.10% speed EA0.80% Cune�lltAMI= 1-80%Low Wx (VGA)ECM 14=1a 2'1=Lepeoy Une 6.FEmd-Speeds 21 NO2-Preferred 2-02% Coadoet Torque 21-21.0' s-B5S6 24.24a^ ::urn Ufae Low NoX 24;000 CFM �ECM -- 0=EwWtlm 0' ' 30=f000 CF7A V-Verlatlo-Speod oM.20,000 BTum g Bgm M-Moduldn0 A 38.12000FM D40-40,000BTUm mM e s.Single Sow B 42-1400 CFM OW.S0.000 Mill T-TNo-fte C 48-IWO CM _ D e0.2000 CFM M-2200 CFM A190042 For California Residents: For installation in SCAQMD only:This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit,and thus is subject to a mitigation fee of up to$450.This furnace is not eligible for the Clean Air Furnace Rebate Program:www.CleanAirFurnaceRebale.com 2 DIMENSIONAL DRAWING zz a I I I a: - c� > 5x S a o ..� ra —., r� �L -•---- , o O _ u !i i i i y M I I I ._ _I_ I - z _ A190084 A B C D ACCESSORY FILTER TOP AND VENT MEDIA CABINET OUTLET BOTTOM FLUE BOTTOM CONNECTION SHIP WE CABINET FURNACE SIZE WIDTH WIDTH COLLAR INLET WIDTH SIZE LB(KG) SIZE 36045V14 14-3/16(360) 12-9/16(319) 9-5/16(237) 12-11/16(322) 4(102) 111 (50) 16(406) 3607OV14 14-3/16(360) A2-9116(810) 9-5/16(237) 12-11/16(322) 4(102) 118(54) 16(406) 4807OV17 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 132(60) 16(406) 4809OV17 17-1/2(445) 15.7/8(403) 11-9/16(294) 16(406) 4(102) 131 (59) 16(406) 6009OV21 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 142(64) 20(506) 6611OV21 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 154(70) 20(506) 66135V24 1 24-1/2(622) 1 22-7/8(581 1 15-1/16(383) 1 23(584) 4(102)* 168�6) 24(610) 1135 size furnaces require a 5 or 6,n. 27 or 152 mm vent. e a vent adapter between urnace and von,stack. Soo Instal anon nstructions or compete installation requirements. 3 SPECIFICATIONS UNIT SIZE 36045V14 3607OV14 4807OV17 4809OV17 6009OV21 6611OV21 66135V24 RAT1N13R ANTI PFRFnRMANrE All Standard High 44,000 66,000 66,000 88,000 88.000 110,000 132,000 Input Btuh` All Luw NOx Upfluw LoW 29,000 43,bUU 43,bU0 b8,000 b8,000 /2,bUU 8/,UUU Nonweatherized All Low Nox High 42,000 63,000 63,000 84,000 84,000 105,000 126,000 ICS Downflow/ Horizontal Low 29,000 43,500 43,500 58,000 58,000 72,500 87,000 All Standard High 35,000 53,000 53,000 71,000 71,000 89,000 107,000 Output Capacity All Low NOx Upflow Low 23,000 35,000 35,000 47,000 47,000 59,000 70,000 (Btuh) Nonweatherized All Low Nox High 34,000 51,000 51,000 68,000 68,000 85,000 102,000 ICS^ Downflow/ Horizontal Low 23,000 35,000 35,000 47,000 47,000 59,000 70,000 AFUE 80.00 High 30-60 30-60 25-55 40-70 25-55 30-60 40-70 Certified Temperature Rise Range (17-33) (17-33) (14-30) (22-39) (14-30) (17-33) (22-39) °F(°C) Low 20-50 30-60 15-45 30-60 15-45 20-50 25-55 (11-28) (17-33) (8-25) (17•••33) (8-26) (11--28) (14-31) Certified External Heat/Cool 0.10/0.50 0,12/0.50 0.12/0.50 0.15/0.50 0.15/0.50 0.20/0.50 0.20/0.50 Static Pressure Airflow CFM T Heating High/Low 915j780 1180/715 1400/1225 1380/1005 1800/1570 2055/1665 2075/1795 Cooling 1175 1380 1740 1505 1915 2230 2160 ELECTRICAL Unit Volts-Hertz-Phase 115-60-1 Operating Volt- age Range Min/Max 104/127 Maximum Unit Amps 7.70 8.00 10.50 8.60 11.50 13.10 13.90 Maximum Wire Length(Measure one way in Ft.(M)) 35(10.9) 34(10.4) 26(8.1) 32(10) 24(7.5) 34(10.4) 32(9.8) Minimum Wire Size 14 14 14 14 14 12 12 Maximum Fuse or Ckt Bkr Size(Amps)** 15 15 15 15 15 20 20 Transformer(24v) 40va 40va 40va 40va 40va 40va 40va External Control Heating 12va 12va 12va 12va 12va 12va 12va Power Available Cooling 35va 35va 35va 35va 35va 35va 35va Air Conditioning Blower Relay Standard CONTROLS Burners(Monoport) 2 3 3 4 4 5 6 Gas Connection Size 1/21n.NPT GAS CONTROLS Mfr. WhiteRodgers Gas Valve Min.inlet pressure 4.5(Natural Gas) (Redundant) (In.W.C.) Max.inlet pressure (In.W.C.) 13.6(Natural Gas) Ignition Device Hot Surface Factory installed orifice Size 43 BLOWER DATA Variable-Speed Constant Torque(VCT)ECM 1/2 112 3/4 1/2 3/4 1 1 Motor Full Load Amps 6.4 6.7 9.2 6.7 9.6 10.9 11.7 RPM(Nominal) 1200 1200 1200 1200 1200 1200 1200 Blower Wheel Diameter x Width -In.(mm) 10 x 6 10 x 6 11 x 8 10 x 10 11 x 11 11 x 11 11 x 11 (254x152) (254x152) (279x203) (254x254) (279x279) (279x279) (279x279) * Gas input ratings are certified for elevations to 2000 ft.(610 M). For elevations above 2000 ft.(610 M),reduce ratings 4 percent for each 1000 ft.(305 M) above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI 7223.1-2012 Table F4 or furnace installation instructions. t Capacity in accordance with U.S.Government DOE test procedures. # Airflow shown is for bottom only return-air supply for Max Cooling Airflow and heating airflows(efficiency setting)at certified external static pressure,For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16 in.(110 mm)wide,high efficiency media filler. ** Time-delay type is recommended, ICS Isolated Combustion System 4 ACCESSORIES DESCRIPTION PART NO. 30045V14 3007OV14 4807OV17 48090V•17 6009OV21 8611OV21 6613SV24 KGBFRO401B14 X X External Bottom Return KGBFRO501B17 X X Fifter Rack KGBFRO601B21 X X KGBFRO701B24 X KGAWF1306UFR X X X X Unframed Filter 3/4-in. KGAWF1406UFR X X (19 mm) KGAWF1506UFR X Flue Extension KGAFE0112UPH X X X X X X X Combustible Floor KGAS60201ALL X X X X X X X Base Downflow Vent Guard KGBVG0101DFG X X X X X X X Vent Extension Kit KGAVE0101DNH X X X X X X X KGAGA02014FC X X X X X X X Chimney Adapter Kit KGACA02015FC X X Natural Kit AGAGC8NPS01A X X X X X X X Conversion Kit* Conversion Propane-to-Nalural AGAGC8PNS01A X X X X X X X Conversion Kit Twinning Kit VCT—ECM Motor gGg7WNPME0IA X X Hlgh Altitude Pressure KGAHA5801PSW X X X X X X X Switch Kit *Factory-aulhor¢ed and field installed.Fuel conversion kits are GSA(formerly AGA/CGA)recognized, X=Accessory ORIFICES LH32DB207 LH32DB202 LH32DB200 LH32DB205 LH32DB208 LH32DBO78 See Installation Instructions for model, Gas Or�ce LH32OB076 altitude,and heat value usages. LH32DB203 LH32DB201 LH32DB206 LH32DB209 LH32DB210 5 ACCESSORIES (continued) DESCRIPTION ACCESSORY HUMIDIFIER Model HUM HEAT AEG VtMY VENT ILAI 11H Model HHV ENERGY RECOVERYVENTiLATOR Model ERV UVt1GHTS Model UVL Bryant has a wide variety of thermostats for your system,please visit iWvW68 yant.com to see all thermostat and IAQ products. DESCRIPTION ACCESSORY 14" 17" 21" 24" Bryant Carbon Monoxide Alarm(10 pack) COALMBBNRB02-AlO X X X X Bryant Evolution Air Purifier-16x25(407x635 mm) DGAPAXX1625 X X Bryant Evolution Air Purifier-20x25(508x635 mm) DGAPAXX2025 X X Bryant Evolution Air Purifier Repl.Filter-16x25(407x635 mm) GAPBBCAR1625-AG5 X X Bryant Evolution Air Purifier Repl.Filter-2ox25(5OBx635 mm) GAPBBCAR2025-AO5 X X Cartridge Media Filter-16"(407 mm)(MERV 11) FILXXCAR0116 X X Cartridge Media Filter-16"(407 mm)(MERV 8) FILXXCAR0016 X X Cartridge Media Filter-20"(508 mm)(MERV 8) FILXXCAR0020 X Cartridge Media Filter-20"(508 mm)(MERVI1) FILXXCAR0120 X Cartridge Media Filter-24"(610 mm)(MERV 8) FILXXCAR0024 X Cartridge Media Filter-24"(610 mm)(MERV11) FILXXCAR0124 X EZ Flex Cabinet Side or Bottom-16" EZXCABCR0016 X X EZ Flex Cabinet Side or Bottom-20" EZXCABCR0020 X X E2 Flex Replacement Filters 16" MERV 10 EXPXXFIL0016 X X EZ Flex Replacement Filters 16" MERV 13 EXPXXFIL0316 X X EZ Flex Replacement Filters 20" MERV 10 EXPXXFIL0020 X EZ Flex Replacement Filters 20" MERV 13 EXPXXFIL0320 X EZ Flex Replacement Filters 24" MERV 10 EXPXXFIL0024 X EZ Flex Replacement Filters 24" MERV 13 EXPXXFIL0324 X EZ-Flex Filter with End Caps-16"(407 mm)(MERV 10) EXPXXUNVO016 X X EZ-Flex ri ter with End Caps-16"(407 mm)(MERV 13) EXPXXUNVO316 X X EZ-Flex Filter with End Caps-20"(508 mm)(MERV 10) EXPXXUNVO020 X EZ-Flex Filter with End Caps-20"(508 mm)(MERV 13) EXPXXUNV0320 X EZ-Flex Filter with End Caps-24"(610 mm)(MERV 10) EXPXXUNVO024 X EZ-Flex Filter with End Caps-24"(610 mm)(MERV 13) EXPXXUNVO324 X Media Filter Cabinet-20" FILCABXL0020 X Media Filter Cabinet-24" FILCABXL0024 X Media Filter Cabinet-16" FILCABXL0016 X X TYPICAL WIRING SCHEMATIC ----FIELD 24-VOLT WIRING ----FIELD 115-,208/230-,460-VOLT WIRING FACTORY 24-VOLT WIRING —FACTORY 115-VOLT WIRING NOTE 2 1-STAGE FIVE w C Y R G THERMOSTAT FIELD-SUPPLIED WIRE 1 TERMINALS FUSED DISCONNECT I 1 I 1 I THREE-WIRE HEATING I I I I 208/230.OR ONLY 460 VOLT THREE w2 i i i i i PHASE BLK B_lK �� L__I I I I - ``-�`- `-- I I I 1 I-- ----- -ff -----' i -- i -- ---P1INGI_E* OLT 0 -- -- 7GND -- _NOTE 1------1—�_ N -- ---115VOLTFIELD• JUNCTION ii HASE SUPPLIED BOX a ______---_ 1 _ rfi1 =GND FUSED CONTROL11 ___ i CONDENSING DISCONNECT BOX GQ --------- UNIT 24-VOLT TERMINAL NOTES:1. Connect Y/Y2-terminal as shown for proper operation. BLOCK 2. Some thermostats require a"C"terminal connection as shown. FURNACE 3. If any of the original wire,as supplied,must be replaced,use same type or equivalent wire. A95236 6 La"u�l iaairT f-. O SEE NOTES: 1,2,4,7,8,9 SEE NOTES:1,2,3,4,7,8,9 SEE NOTES:1,2,4,5,7,8,9 UPFLOW UPFLOW DOWNFLOW A02058 A02059 A02061 _ I i �. o. z �---- SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES:1,2,4,5,6,7,8,9 DOWNFLOW DOWNFLOW DOWNFLOW A02060 A02063 A02062 Venting Notes 1. For common vent,vent connector sizing and vent material:United States,latest edition of the National Fuel Gas Code NFGC),ANSI Z223.1/NFPA 54. 2. Immediately increase to 5-in.(127 mm)vent connector outside furnace casing when 5-in.(127 mm)vent connector required,refer to Note 1. 3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the fumace, except when Downflow Vent Guard is used in downflow position. 4. Type B vent where required,refer to Note 1. 5. 4—in.(102 mm)single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit. 6. Accessory Downflow Vent Guard Kit,required in downflow installations with bottom vent configuration. 7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing and complete application details. 8. Secure vent connector to furnace elbow with(2)corrosion-resistant sheet metal screws,space approximately 180° apart. 9. Secure all other single wall vent connector joints with(3)corrosion-resistant screws spaced approximately 120' apart. Secure Type B vent connectors per vent connector manufacturer's recommendations. 7 umur SEE NOTES:1,2,4,5,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL RIGHT HORIZONTAL RIGHT A0206B A02070 1' O I - SEE NOTES:1,2,4,7,8,9 HORIZONTAL RIGHT A02069 1WWW� -- 1 1 7 U O SEE NOTES: 1,2,4,7,8,9 SEE NOTES:1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02064 A02065 I ; 1 �I J, o I ,1 SEE NOTES:1,2,4,5,7,8,9 SEE NOTES:1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02066 A02067 8 AIR DELIVERY—CFM (With Filter)* COOLING4 AND HEATING AIR DELIVERY-CFM(Bottom Returns With Filter) (SW1-5 and SW2-2 set to OFF,except as indicated.See notes 1 and 2.) Unit Size:36045V14 CIg/CF Switch settings External Static Pressure(ESP) CIg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CIg Default: OFF OFF OFF 1190 1140 1100 1065 1020 985 905 800 665 525 OFF OFF ON 620 560 520 455 410 355 305 255 See note 4 OFF ON OFF 795 755 705 670 615 585 530 490 440 405 OFF ON ON 1020 955 930 890 840 805 755 715 645 490 Cooling ON OFF OFF 1190 1140 1100 1065 1020 985 905 800 665 525 (SW2-8,7,6) ON OFF ON 1455 1390 1326 1255 1175 1085 1000 880 755 575 ON ON OFF 1455 1390 1325 1255 1175 1085 1000 880 755 575 ON ON ON 1455 1390 1325 1255 1175 1085 1000 880 755 575 Maximum Cig Airflow 1455 1390 1325 1255 1175 1085 1000 880 755 1 575 CF Switches SW2-6 1 S.W2-4, SW2-3, Low-CIg Default: OFF OFF OFF 620 560 520 455 410 355 305 255 See note 4 OFF OFF ON 620 560 520 455 410 355 305 255 See note 4 OFF ON OFF 795 755 705 670 615 585 530 490 440 405 Low-Cooling OFF ON ON 1020 955 930 890 840 805 755 715 645 490 (SW2-5,4,3) ON OFF OFF 1190 1140 1100 1065 1020 985 905 800 665 525 ON OFF ON 1455 1390 1325 1255 1175 1085 1000 880 755 575 ON ON OFF 1455 1390 1325 1255 1175 1085 1000 880 755 575 ON ON ON 1455 1390 1325 1255 1175 1085 1000 880 755 575 Cont.Fan Default: OFF OFF OFF 620 560 520 455 410 355 305 255 See note 4 OFF OFF ON 620 560 520 455 410 355 305 255 See note 4 OFF ON OFF 795 755 705 670 615 585 530 490 440 405 Continuous Fan OFF ON ON 1020 955 930 890 840 805 755 715 645 490 (SW2-5,4,3) ON OFF OFF 1020 955 930 890 840 805 755 715 645 490 ON OFF ON 1020 955 930 890 840 805 755 715 645 490 ON ON OFF 1020 955 930 890 840 805 755 715 645 490 ON ON ON 1020 1 955 930 890 840 805 755 715 645 490 Healing High Heat Alrnow3 915 860 825 790 735 700 650 610 550 1 450 (SW1) Low Heat Airflow' 780 730 685 635 1 585 545 495 450 400 1 370 Unit Size:36070V14 CIg/CF Switch settings External Static Pressure(ESP) Cig Switches: SW2-8 SW2-7 I SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0:8 f 0.9 -1.0 Cig Default: OFF OFF OFF 1155 1125 1095 1065 1035 1005 975 950 915 875 OFF OFF ON 606 555 500 440 375 320 265 See note 4 OFF ON OFF 775 735 690 650 600 550 500 450 405 365 OFF ON ON 980 950 915 880 845 810 775 735 695 655 Cooling ON OFF OFF 1155 1125 1095 1065 1035 1005 975 950 915 875 (SW2-8,7,6) ON OFF ON 1370 1340 1310 1285 1260 1235 1210 1140 1025 880 ON ON OFF 1505 1480 1455 1420 1380 1335 1250 1155 1045 900 ON ON ON 1505 1480 1455 1420 1380 1335 1250 1155 1045 900 Maximum Cig Airflow 1505 1480 1455 1420 1380 1335 1250 1155 1 1045 1 900 CF Switches SW2-5 SW24 SW2-3 Low-Clg Default: OFF OFF OFF 605 555 500 440 375 320 265 See note 4 OFF OFF ON 605 555 500 440 375 320 265 See note 4 OFF ON OFF 775 735 690 650 600 550 500 450 405 365 OFF ON ON 980 950 915 880 845 810 775 735 695 655 Low-Cooling (SW2-5,4,3) ON OFF OFF 1155 1125 1095 1065 1035 1005 975 950 915 875 ON OFF ON 1370 1340 1310 1285 1260 1235 1210 1140 1025 880 ON ON OFF 1505 1480 1 1455 1 1420 1380 Z1335 1250 1155 1045 900 ON ON ON 1505 1480 1 1455 1 1420 1380 1 1335 1 1250 1 1155 1045 900 Cont.Fan Default: OFF OFF OFF 605 555 500 440 375 320 265 See note 4 OFF OFF ON 605 555 500 440 375 320 265 See note 4 OFF ON OFF 775 735 690 650 600 550 500 450 405 365 OFF ON ON 980 950 915 880 845 810 775 735 695 655 Continuous Fan ON OFF OFF 1155 1125 1095 1065 1035 1005 975 950 915 875 (SW2-5,4,3) ON OFF ON 1370 1340 1310 1285 1260 1235 1210 1140 1025 880 ON ON OFF 1370 1340 1310 1285 1260 1235 1210 1140 1025 880 ON ON ON 1370 1340 1310 1285 1260 1235 1210 1140 1025 880 Heating High Heat Alrflow3 1190 1 1160 1130 1100 1 1070 1045 1 1015 1 985 1955 900 (SW1) Low HeatAirflow3 725 1 680 635 585 1 530 475 1 425 1 375 1 30 285 9 AIR DELIVERY—CFM (With Filter)* (Continued) COOLING4 AND HEATING AIR DELIVERY-CFM(Bottom Returns With Filter) (SW1-5 and SW2-2 set to OFF,except as indicated.See notes 1 and 2.) Uiiii.Sicn:46070V j7 GiyiGF Swiicii seHings Externai Static rressure(ESPI ; QitW.tcIiQ SWM SW2-7 SW2-6 0.1 0.2 0.3 0,4 0,5 0.6 0:7 0,8 0:9 1 1.0 Clg Default: OFF OFF OFF 1600 1570 1535 1500 1465 1430 1400 1 1365 1335 1300 OFF OFF ON 590 520 440 365 300 235 See note 4 OFF ON OFF 790 730 670 610 550 485 430 380 330 275 OFF ON ON 1025 980 930 880 835 785 735 690 635 590 Cooling ON OFF OFF 1230 1190 1150 1105 1065 1025 980 940 900 860 (SW2-8,7,6) ON OFF ON 1390 1355 1 315 1 1280 1240 1200 1165 1125 1090 1055 ON ON OFF 1600 1570 1 1535 1 1500 1465 1430 1400 1365 1335 1300 ON ON ON 1855 1830 1800 1770 1740 1695 1645 1600 1520 1415 Maximum Clg AIrffow2 1855 1830 1800 1770 1740 1 1695 1645 1600 1520 14 55 CF Switches SW2-5 SW2-4 SW2-3 Low-Clg Default: OFF OFF OFF 590 520 440 365 300 235 See note 4 OFF OFF ON 590 520 440 365 300 235 See note 4 OFF ON OFF 790 730 670 610 550 485 430 380 330 275 OFF ON ON 1025 980 930 880 835 785 735 690 635 590 Low-Cooling ON OFF OFF 1230 1190 1150 1105 1065 1025 980 940 900 860 (SW2-5,4,3) ON OFF ON 1390 i355 1315 1280 1240 1200 1165 1125 1090 1055 ON ON OFF 1600 1570 1535 1500 1465 1430 1400 1365 1335 1300 ON ON ON 1855 1830 1800 1770 1740 1695 1645 1600 1520 1415 Cont.Fan Default: OFF OFFPFF 590 520 440 365 300 235 See note 4 OFF OFF 590 520 440 365 300 235 See note 4 OFF ON 685 625 565 505 445 385 325 265 See note 4 OFF ON 790 730 670 610 550 485 430 380 330 275 Continuous Fan ON OFF 790 730 670 610 550 485 430 380 330 275 (SW2-5,4,3) ON OFF 790 730 670 610 550 485 430 380 330 275 ON ON 790 730 670 610 550 485 430 380 330 275 ON ON ON 790 730 670 610 550 485 430 380 330 275 Heating High Heat Airflow 1410 1375 1340 1300 1260 1225 1190 1155 1120 1085 (SW1) Low Heat Airflow 1235 1195 1155 1 1110 1 1070 1 1025 985 945 905 865 Unit Size:48090V17 CIg1CF Switch settings External Static Pressure(ESP) Clg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Clg Default: OFF OFF OFF 1560 1520 1485 1450 1415 1380 1340 1300 1260 1115 OFF OFF ON 680 605 495 415 345 275 See note 4 OFF ON OFF 835 770 700 600 535 465 410 350 285 240 OFF ON ON 1035 980 930 870 795 720 665 605 555 505 Cooling ON OFF OFF 1210 1165 1125 1080 1030 975 905 845 790 740 (SW2-8,7,6) ON OFF ON 1375 1335 1300 1260 1220 1175 1125 1075 1010 955 ON ON OFF 1560 1520 1485 1450 1415 1380 1340 1300 1260 1115 ON ON ON 1640 1605 1570 1540 1505 1470 1435 1390 1325 1110 Maximum Clg Alrflow 1640 1605 1570 1540 1505 1470 1435 1390 1325 11 00 CF Switches SW2-5 SW2-4 SW2-3 Low-Clg Default: OFF OFF OFF 680 605 495 415 345 275 See note 4 OFF OFF ON 680 605 495 415 345 275 See note 4 OFF ON OFF 835 770 700 600 535 465 410 350 285 240 OFF ON ON 1035 980 930 870 795 720 665 605 555 505 Low-Cooling(SW2-5,4,3) ON OFF OFF 1210 1165 1125 1080 1030 975 905 845 790 740 ON OFF ON 1375 1335 1300 1260 1220 1175 1125 1075 1010 955 ON ON OFF 1560 1520 1485 1 1450 1 1415 1380 1340 1300 1260 1115 ON ON ON 1640 1 1605 1570 1 1540 1 1505 1 1470 1435 1390 1325 1110 Cont.Fan Default: OFF OFF OFF 680 1 605 495 415 345 275 See note 4 OFF OFF ON 680 605 495 415 345 275 See note 4 OFF ON OFF 835 770 700 600 535 465 410 350 285 240 OFF ON ON 1035 980 930 870 795 720 665 605 555 505 Continuous Fan(SW2-5,4,3) ON OFF OFF 1210 1165 1125 1080 1030 975 905 845 790 740 ON OFF ON 1375 1335 1300 1260 1220 1175 1125 1075 1010 955 ON ON OFF 1560 1520 1 1485 1 14El]415 1 1380 1340 1300 1260 1115 ON ON ON 1560 1 1520 1 1485 1 1450 1 1415 1 1380 1340 1300 1260 1115 Heating High Heat Airflow3 1400 1 1360 1 1325 1 1285 1 1245 1 1200 1 1155 1 1110 1 1045 995 (SW1) Low Heat Airflow3 1035 1 980 1 930 1 870 1 795 1 720 1 665 1 605 1 555 505 t0 AIR DELIVERY—CFM (With Filter)* (Continued) COOLING4 AND HEATING AIR DELIVERY-CFM(Bottom Returnb With Filter) (SW1-5 and SW2-2 set to OFF,except as indicated.See notes 1 and 2.) Unit Size:60090V21 Clg/CF Switch settings External Static Pressure(ESP) Clg Switches: SW2-8 SW2-7 4W2�6', 0.1 0.2 0.3 0.4 0.5 1 0A 0.7 018 0;9 1.0 CIg Default: OFF OFF OFF 1985 1935 1885 1835 1785 1735 1685 1630 1 1583 1532 OFF OFF ON 860 755 650 545 445 350 235 1 See note 4 OFF ON OFF 1085 1000 910 830 735 655 565 485 405 310 OFF ON ON 1255 1180 1105 1025 950 870 790 715 640 670 Cooling ON OFF OFF 1425 1355 1290 1220 1150 1085 1015 940 870 800 (SW2-8,7,6) ON OFF ON 1630 1575 1515 1455 1395 1330 1270 1210 1155 1090 ON ON OFF 1985 1935 1885 1835 1785 1735 1685 1630 1583 1532 ON ON ON 2100 2055 2010 1960 1915 1870 1820 1775 1715 1640 Maximum CIg Airflow2 2100 2055 2010 1 1960 1915 1870 1820 1 1775 1 1715 1640 CF Switches SW2-5 SW2-4 SW2-3 Low-Clg Default: OFF OFF OFF 860 755 650 545 445 350 235 T See note 4 OFF OFF ON 700 575 455 345 225 See note 4 OFF ON OFF 860 755 650 545 445 350 235 See note 4 OFF ON ON 1085 1000 910 830 735 655 565 485 405 310 (SW2-5-5,4n,3)Low ON OFF OFF 1255 1180 1105 1025 950 870 790 715 640 570 ON OFF ON 1425 1355 1290 1220 1150 1085 1015 940 870 800 ON ON OFF 1630 1575 1515 1455 1 1395 1 1330 1270 1210 1155 1090 ON ON ON 1985 1935 1885 1835 1785 1735 1685 1630 1583 1532 Cont.Fan Default: OFF OFF OFF 860 755 650 545 445 350 1 235 See note 4 OFF OFF ON 700 575 455 345 225 See note 4 OFF ON OFF 860 755 650 545 445 350 235 See note 4 OFF ON ON i085 1000 910 830 735 655 565 485 405 310 Continuous Fan(SW2-5,4,3) ON OFF OFF i255 1180 ii05 i025 950 870 790 7i5 640 570 ON OFF ON i255 1180 1105 1025 950 870 790 7i5 640 570 ON ON OFF 1255 1180 i 105 1025 —750-1 870 790 7i5 640 570 ON I (7_1 ON 1255 1 1180 1105 1 1025 1 950 1 870 790 7i5 640 570 Heating High Heat Airflow- 1830 1775 1725 1675 1625 1 1570 1 1520 1 1465 1410 1360 (SW1) Low Heat Airflow° 1600 1540 1485 1430 1370 1 1315 1 1255 1 1195 1140 1070 Unit Size:66110V21 Clg/CF Switch settings External Static Pressure(ESP) Clg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 .8 0.9 1.0 Clg Default: OFF OFF OFF 2055 2000 1950 1900 1 1840 1790 1740 1675 1625 1565 OFF OFF ON 855 755 See note 4 OFF ON OFF 1060 985 875 800 700 See note 4 OFF ON ON 1250 1180 1095 1025 925 860 775 715 See note 4 Cooling ON OFF OFF 1445 1380 1320 1235 1175 1100 1035 955 900 825 (SW2-8,7,6) ON OFF ON 1685 1630 1560 i505 1445 i375 1320 1265 1195 1140 ON ON OFF 2055 2000 1950 1900 1840 1790 1740 1675 1625 1565 ON ON ON 2465 2415 2365 2305 2230 2140 2045 1925 1805 1655 Maximum CIg Airnowl 2465 1 2415 2365 2305-1 2230 2140 2045 1925 1805 1655 CF Switches SW2-5 SW2-4 SW2-3 Low-Clg Default: OFF OFF OFF 855 755 See note 4 OFF OFF ON 640 540 See note 4 OFF ON OFF 855 755 See note 4 OFF ON ON 1060 985 875 800 700 See note 4 Low-Cooling ON OFF OFF 1250 1180 1095 i025 925 860 775 715 See note 4 (SW2-5,4,3) ON OFF ON 1445 1380 1320 1235 1175 1100 1035 955 900 825 ON ON OFF 1685 1630 1560 1505 1445 1375 1320 1265 ii95 1140 rON ON ON 2065 2000 1950 1900 1840 1790 1740 1675 1825 1565 Cont.Fan Default: OFF OFF OFF 855 755 See note 4 OFF OFF ON 640 540 See note 4 OFF ON OFF 855 755 See note 4 OFF ON ON 1060 985 875 800 700 See note 4 Continuous Fan(SW2-5,4,3) ON OFF OFF 1250 1180 1095 1025 925 860 775 715 See note 4 ON OFF ON 1445 1380 1 1320 1235 1175 1100 1035 955 900 825 ON ON OFF 1445 1380 1320 1235 1175 1100 1036 955 900 825 ON ON ON 1445 1380 1320 1236 1175 1100 1035 955 900 825 Heating High Heat Airflow 2105 2055 1 2005 1955 1 1895 1 1850 1795 1 1735 1665 1580 (SW1) Low Heat Airiiow3 1740 1 1685 1 1620 1560 1 1505 1 1440 1385 1 1325 1260 1205 11 AIR DELIVERY—CFM (With Filter)* (Continued) COOLING"AND HEATING AIR DELIVERY-CFM(Bottom Return'With Filter) (SW1-5 and SW2-2 set to OFF,except as Indicated.See notes 1 and 2.) Unit Size'66135V24 r.lgrrF Swatch a External Static Pressure(EEP; Clg S:{h!res: SW2-8. S0: SW2-S 0.1 0.2 0.3 0A 0.5 0.6 0.7 0.8 0.9 1.0 Clg Default: OFF_ OFF OFF 2105 2050 1996 1940 1880 1820 1/bb 1 1/Ob 16bU 159U OFF OFF ON 990 885 780 665 570 See note 4 OFF ON OFF 1180 1090 995 900 815 715 635 555 475 400 OFF ON ON 1355 1270 1190 1105 1020 940 855 775 70U 630 Cooling ON OFF OFF 1535 1465 1395 1320 1245 1165 1095 1025 945 875 (SW2-8,7,6) ON OFF ON 1735 1670 1605 1535 1470 1405 1335 1270 1205 1140 ON ON OFF 2105 2060 1995 1940 188-0 1820 1765 1705 1650 1590 ON ON ON 2280 2225 2175 P120 2065 2010 1955 1905 1850 1800 irfl Maximum Cig Aow 7 2360 2310 2265 2215 2160 2115 2060 2010 1960 1870 OF Switches SW2-5 SW2.4 SW2-3 Low-Cig Default: OFF OFF OFF 990 885 780 665 570 See note 4 OFF OFF ON I 80U 670 540 410 280 See note 4 OFF ON OFF 990 885 780 665 570 See note 4 OFF ON ON 1180 1090 995 900 815 715 635 555 475 400 Low-Cooling(SW2-5,4,3) ON OFF OFF 1355 1270 1190 1105 1020 940 855 775 700 630 ON OFF ON 1535 1465 1395 1320 1245 1165 1095 1025 945 875 ON ON OFF 1735 rl6 00 1605 1535 1470 1405 1335 1270 1205 1140 ON ON ON 2105 1 2050 1096 1940 1880 1820 1765 1705 1650 1590 Cont.Fan Default OFF OFF OFF 740 605 470 360 255 See note 4 OFF OFF ON 740 605 470 360 255 See note 4 OFF ON OFF 900 775 650 525 400 See note 4 Continuous Fan OFF ON ON 1080 980 885 785 680 595 510 430 345 260 (SW2-5,4,3) ON OFF OFF 1080 980 885 785 680 595 510 430 345 260 ON OFF ON 1080 980 885 785 680 595 510 430 345 260 ON ON OFF 1080 980 885 785 680 595 510 430 345 260 ON ON I ON 1080 980 885 785 680 595 510 430 345 260 Heating High Heat Airflow' 2130 2075 2020 1 1970 1910 1855 1805 1745 1690 1630 (SW1) Low Heat Airflow3 1855 1795 1730 1 1670 1605 1545 1480 1420 1360 1300 1. Nominal 350 CFM/ton cooling airflow is delivered with SW1-5 and SW2-2 set to OFF. Set both SW1-5 and SW2-2 to ON for+7%airflow(nominal 370 CFM/ton). Set SW1-5 to ON and SW2-2 to OFF for+15%airflow(nominal 400 CFM/ton). Set SW2-2 to ON and SW1-5 to OFF for-7%airflow(nominal 325 CFM/ton). The above adjustments in airflow are subject to motor horsepower range/capacity. This applies to Cooling and Low-Cooling alrflow,but does not affect continuous fan airflow. 2. Maximum cooling airflow is achieved when switches SW2-6,SW2-7,SW2-8 and SW1-5 are set to ON,and SW2-2 is set to OFF. 3. All heating CFM's are when comfort/efficiency adjustment switch(SW1-4)is set to OFF 4. Ductwork must be sized for high-heating CFM within the operational range of ESP.Operation within the blank areas of the chart is not recommended because high-heat operation will be above 1.0 ESP. 5. All airflows on 21"casing size furnaces are 5%less on side return only installations. 6. Side returns for 24.5"casing sizes require two sides,or side and bottom,to allow sufficient airflow at the return of the furnace. 7. Airflows over 1800 CFM require bottom return,two-side return,or bottom and side return or excessive wait draw may result.A minimum filter size of 20x25"(508 x 635 mm)is required. 12 A WARNING INSTALLATION FIRE,EXPLOSION, MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION ASPHYX1ATTON HAZARD This forced air furnace is This furnace is approved or equipped for use with natural UPFLOW,DOWNFLOW, and Improper adjustment,alteration,service, gas at altitudes 0- 10,000 It HORIZONTAL installations. maintenance,or installation can cause (0-3,050m). Clearance arrows serious injury or death. An accessorykit lied b do not change with , supplied Y � furnace orientation. the manufacturer, shall be used w Read and follow Instructions and to convert to propane gas use precautions in User's Information Manual or may be required for some BA o ,�°E *c provided with this furnace. Installation natural gas applications. CK fcti and service must be performed by a This furnace is for indoor F��a qualified service agency or the gas installation in a building FCC SeN supplier. constructed on site. This furnace may be installed ,A CAUTION on combustible flooring in alcove ' c e " or closet at minimum clearance Check entire gas assembly for leaks after as indicated by the diagram lighting this appliance. from combustible material. e" This furnace may be used with t Clearance in inches INSTALLATION a Type B-1 Vent and may be Vent Clearance to combustibles: 1.This furnace must be installed in vented in common with other For Single Wall vents 6 inches(6 po). accordance with the manufacturer's gas fired appliances. For Type B-1 vent type 1 inch(1 po). instructions and local codes. In the absence of local codes,follow the National MINIMUM INCHES CLEARANCE TO Fuel Gas Code ANSI Z223.1 /NFPA54 COMBUSTIBLE CONSTRUCTION or CSA B-149. 1 Gas Installation Code. 2.This furnace must be installed so there are DOWNFLOW POSITIONS: provisions for combustion and ventilation air. See manufacturer's installation t Installation on non-combustible floors only. information provided with this appliance. For Installation on combustible flooring only when installed on special base, Part No.KGASB0201ALL or NAHA01101SIB,Coil Assembly, OPERATION Part No.CAR,CAP,CNPV,CNRV,END4X,ENW4X,WENC,WTNC, This furnace is equipped with manual reset WENW OR WTNW. limit switch(es)in burner compartment to 0 18 inches front clearance required for alcove. protect against overheat conditions that can result from inadequate combustion air ie Indicates supply or return sides when furnace is in the horizontal supply or blocked vent conditions. position. Line contact only permissible between lines formed by 1. Do not bypass limit switches. intersections of the Top and two Sides of the furnace jacket, 2. If a limit opens,call a quallified and building joists,studs or framing. Inilll�lll�l�II�IIIn IIIIIIIII� serviceman to correct the condition IIJIII UlJ�lllllUl and reset limit switch. 336996-101 REV.c Al 0269 13 GUIDE SPECIFICATIONS Gas Furnace casine 820TA/821TA Casing shall be of .030 in. (.76 mm) thickness minimum, *,a:..re.1 Drool General SYSTEM DRSCRIlYHON Two SaeedinducerMotor Two Speed Inducer motor shall be soft mounted to reduce Furnish a fixed capacity gas-fired furnace for vibration transmission. use with natural gas or propane(factory authorized conversion kit Draft Snfeettord Switch required for propane);furnish cold air return plenum. QUALITY ASSURANCE Draft Safeguard Switch (blocked vent safeguard)shall be factory installed to reduce the possibility of vent gas infiltration due to a Unit will be designed,tested and constructed to the current ANSI Z blocked or restricted vent pipe. 21.47/CSA 2.3 design standard for gas-fired central furnaces. Heat Fxchunimrs Unit will be 3rd party certified by CSA to the current ANSI Z Heat exchangers shall be a 4-Pass 20 gage aluminized steel of 21.47/CSA 2.3 design standard for gas-fired central furnaces. fold-and-crimp sectional design when applied operating under Unit will carry the CSA Blue Stara label• negative pressure. Unit efficiency testing will be performed per the current DOE test Controls procedure as listed in the Federal Register. Control shall include a micro-processor based integrated electronic Unit will be certified for capacity and efficiency and listed in the control board with at least 11 service troubleshooting codes latest AHRI Consumer's Directory of Certified Efficiency Ratings. displayed via diagnostic flashing enhanced LED light on the Unit shall carry the current Federal Trade Commission Energy control, a self-test feature that checks all major functions of the Guide efficiency label. furnace within one minute, and a replaceable automotive-type DELIVERY.STORAGE AND HANDLING circuit protection fuse. Multiple operational settings available Unit shall be shipped as single package only and is stored and including, separate blower speeds for low heat, high heat, low handled per unit manufacturer's recommendations. cooling, high cooling and continuous fan. Continuous fan speed may be adjusted from the thermostat. Cooling airflow will be WARRANTY(for inclusion by specifying engineer) selectable between 350 or 400 CFM per ton of air conditioning. U.S.only.Warranty certificate available upon request. Features will also include temporary reduced airflow in the cooling Products mode for improved dehumidification when a control or Thermidistat' is selected as the thermostat. EQUIPMENT OPERATING CHARACTERISTICS Components shall include: slow-opening two stage gas valve to Heating Capacity shall be Btuh input; Btuh reduce ignition noise, regulate gas flow, with electric switch gas output capacity. shut-off;flame proving sensor,hot surface igniter,pressure switch assembly,flame rollout switch,blower and inducer assembly,40va Fuel Gas Efficiency shall be 80%AFUE. transformer;low-voltage(heating)(heating/cooling)thermostat. Air delivery shall be CFM minimum at 0.50 in. Blower Wheel and Blower Motov W.C.external static pressure. Galvanized blower wheel shall be centrifugal type, statically and Dimensions shall be: depth in. (mm); width dynamically balanced. Blower motor of ECM type shall be in. (mm); height in. (mm). (casing only). permanently lubricated with sealed bearings, of hp, and Height shall be in. (nun), with A/C coil and shall be multiple-speed direct drive. Blower motor shall be soft in.(mm)overall with plenum. mounted to the blower scroll to reduce vibration transmission. ELECTRICAL REQUIREMENTS Filters Electrical supply shall be 115 volts,60 Hz,single-phase(nominal). Furnace may have reusable-type filters.Filter shall be (x) Minimum wire size shall be AWG;maximum fuse size in. (mm). An accessory high efficiency Media Filter is or circuit breaker shall be _Amps. available as an option. Media Filter. SPECIAL E,EATURES Refer to section of the product data sheet identifying accessories and descriptions for specific features and available enhancements. ©2019 Bryant Heating&Coohng systems 7310 W.Monis St, Indianapolis.IN 46231 Edition Date:3119 Catalog No.PDS820TA-01 manufacturer reserves Me fight o discontinue.or c enga any o,spa ca ons ar es gns vn ou no co a �H u mcurnng o ga ono. Replaces:NEW 14 Home Espafiol Contact Aft Labor' o Workplace Rights 9 Trades&Licensing 19 Aft Washington State Department of " Labor & Industries DAY& NITE PLG & HTG INC Owner or tradesperson 1661413TH AVE W Principals LYNNWOOD,WA 98037 DAVIS,BRUCE ALLEN SR,PRESIDENT 425-775-6464 SNOHOMISH County ■ DAVIS,JUDITH LEE,VICE PRESIDENT DAVIS,BRUCE ALLEN JR,SECRETARY DAVIS,BRUCE ALLEN SR,AGENT ■ KRPAN,DAN,SECRETARY (End:05105/2007) Doing business as DAY&NITE PLG&HTG INC WA UBI No. Business type 600 061 976 Corporation Governing persons BRUCE A DAVIS DAN KRPAN; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL CC-EC Domestic Pump License no. DAYNIPH944RQ Effective—expiration 01/18/2007—01/01/2021 Bond American Contractors Indem CO $12,000.00 Bond account no. 100239880 Received by L&I Effective date 01/29/2014 02/04/2014 Expiration date Until Canceled CBIC $12,000.00 Bond account no. 626568 Received by L&I Effective date 12/18/2006 01/02/2002 Expiration date Until Canceled Insurance Ohio Security Ins Co $1,000,000.00 Policy no. BKS55998671 Received by L&I Effective date 03/18/2019 04/02/2016 Expiration date 04/02/2020 Federated Mutual Ins Co $2,000,000.00 Policy no. 1704022 Received by L&I Effective date 04/01/2019 04/01/2019 Expiration date 04/01/2020 Insurance history Savings ................ .... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations Infraction no. PBATI01165 Satisfied Issue date RCW/WAC 09/22/2015 18.106.020 Violation city Violation amount LYNNWOOD $250.00 Type of violation PLUMBER INFRACTION Description Contractor failed to provide proper supervision as required. Infraction no. PBATI01164 Satisfied Issue date RCW/WAC 09/22/2015 18.106.020 Violation city Violation amount LYNNWOOD $250.00 Type of violation PLUMBER INFRACTION Description Contractor failed to provide proper supervision as required. Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent Not allowed to have apprentices. Help us improve Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. This company has multiple workers'comp accounts. Active accounts L&I Account ID Account is current. 505,651-00 Doing business as DAY&NITE PLUMBING&HEATING Estimated workers reported Quarter 2 of Year 2019"31 to 50 Workers" L&I account contact T3/LAURIE BROWN(360)902-0679-Email:BRLB235@lni.wa.gov Track this contractor 0 Public Works Requirements Verify the contractor is eligible to perform work on public works projects. Required Training—Effective July 11,2019 Exempt from this requirement. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. lcccaa Help us improve �1Yashinuton° .- ��, t RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:437 S Olympic Ave Project Description:Replace existing gas furnace with new gas furnace in same location, no new gas Owner: Heidi Young Address. 437 S Olympic Ave City. Arlington State.WA Zip Code: 98223 Phone. 425-293-9914 Email:heidi919@comcast.net Applicant: Day and Nite Plumbing and Heating Address: 16614 13th Ave W City: Lynnwood State.WA Zip Code: 98037 Phone. 425-775-6464 Email. bryan@dayandnite.net CONTRACTOR INFORMATION Contractor Name:Day and Nite Plumbing and Heating Address: 16614 13th Ave W City. Lynnwood State.WA Zip Code: 98037 License Number. DAYNIPH944RQ Expiration: 01/01/21 Phone: 425-775-6464 Email:bryan@dayandnite.net STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #820TA3607OV14 AFUE 80 ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: [El Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances L �r✓ar�c"�6K--&ff� Applicant Signature: 13be"a92O�db81'b61e6' Date: 10/05/2019 Applicant Printed Name: Bryan Radcliff I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 -'Y C OF ARLNC.-.�TON 01 , f � -o 238 N. OLYMPIC AVE-ARLINGTON,WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:437 S.Olympic Ave Permit#:2831 Parcel#:00411700701900 Valuation:.00 1OWNER APPLICANT CONTRACTOR Name:YOUNG HEIDI Name:Day and Nite Plumbing and Heating Name:Day&Nite Plumbing&Heating,Inc Address:437 SOUTH OLYMPIC AVE Address:16614 13th Ave W. Address:16614 13th Ave W City,State Zip:ARLINGTON,WA 98223 City,State Zip:Lynnwood,WA 98037 City,State Zip:Lynnwood,WA 98037 Phone: Phone:425-775-6464 Phone:425-775-6464 LIC: EXP: MECHANICAL CONTRACTOR db PLUMBING CONTRACTOR Name:Day&Nite Plumbing and Heating Name: Address:16614 13th Ave W Address: City,State,Zip:Lynnwood,WA 98037 City,State,Zip: Phone:425-775-6464 Phone: LIC M DAYWH944RQ EXP: 01/01/2021 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/1RC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form an d rlin on#3101. n nn Lo Q I I)e&E 10•$'�1 10/8/2019 Signature Print Name Date R e'M ashe'd By Date CONDITIONS Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/07/2019 Furnace $25.00 10/07/2019 Mechanical Permit Base Fee $25.00 10/07/2019 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon : I 4-Way Multipoise Induced Combustion Sizes 045 thru 135 1=0 Product Data PERFORMANCE ' ® ® • Perfect Heat®operation ®® Two-stage heating even with single-stage thermostat-patented I �Ez-:� Adaptive Control Technology Q ®® Reduced operating sound through low-stage operation and ®® sound elimination combustion system • Two-stage heating with single-stage thermostat with t�E�®® patented Adaptive Control Technology ® • Microprocessor based"smart"control center Fan on-Continuous Fan speed adjustable from thermostat Adjustable heating air temperature rise r ' Adapts heating stages to meet demand Dehumidify mode Enhanced diagnostics with LED and reflective sight glass, non-volatile fault code memory,and self test feature On-board fuse for transformer protection • Perfect Light- Igniter • Patented blocked vent safeguard to ensure proper furnace venting • Insulated blower compartment • Inner door for tighter sealing 4 • Variable-speed ECM blower motor Increased SEER ratings for AC and HP systems as compared to A10252 the Air Conditioning Heating and Refrigeration Institute's THE TWO-STAGE GAS FURNACE standard coil-only rating when paired with selected Bryant The Two-stage,Variable-speed,4-way Multipoise Gas Furnace evaporator coils. offers outstanding comfort in an 80%AFUE furnace. Perfectly matches CFM to cooling system at all static points You get the benefits of Perfect Heat—: reduced drafts, reduced . Noise elimination combustion system sound levels, longer cycles, less temperature swings between INSTALLATION FLEXIBILITY cycles,less temperature differences between rooms, and improved indoor air quality. Plus, it features a dehumidify mode and the • 4-way Multipoise furnace,13 vent applications ability to change continuous fan speeds from the thermostat. The . Compact design-only 33-1/3 in.(847 mm)tall 820TA/821TA furnaces are approved for use with natural or propane gas.821TA - Low NOx units are designed for California APPLICATIONS installations and meet 40 ng/J NOx emissions. Can be installed in • SmartEvap- can lower the humidity level in the home by air quality management districts with a 40 ng/J NOx emissions nearly 10 percent requirement. • All models are Chimney friendly when used with accessory t rur•,� vent kit oEs t cN �' • HYBRID HEAT®Dual Fuel System compatible sP CERTIFICATION CFRTIF�F'�® ISO 900'1 • Cabinet air leakage less than 2.0%at 1.0 in.W.C.and cabinet air leakage less than 1.4%at 0.5 in.W.C.when tested in accordance with ASHRAE standard 193 CERTIFIED- ..­h,1d1­1..V­9 • Residential installations eligible for consumer financing Use of the AHRI Certified TM Mark indicates a through the Retail Credit Program manufacturer's participation in the program.For verification of certification for individual products, go to mvw.ahridirectory.org. FURNACE COMPONENTS INDUCER MOTOR VENT ASSEMBLY ELBOW MAIN LIMIT SWITCH PRESSURE (BEHIND GAS VALVE) SWITCH u BLOCKED VENT SWITCH FLUE COLLECTOR BOX e u C FLAME GAS VALVE (' SENSOR AI % 0 � MANUAL RESET GAS MANIFOLD LIMIT SWITCHES 0 0 HOT SURFACE IGNITOR O 6 GAS BURNER o BLOWER DOOR SAFETY SWITCH _ 0 FURNACE CONTROL -- BOARD 4 ® BLOWER AND A MOTOR � jtl A190086 NOTE: The furnaces are factory shipped for use with natural gas. These furnaces can be field-converted for propane gas with a factory-authorized and listed accessory conversion kit. EXAMPLE OF MODEL NUMBER NOMENCLATURE 1 2 3 4 5 8,7 B-10 11 12-13 14 15 18 Hest M*r Cooling Vftpe Mror Eta)&W Tier/Wx AFUEM FkWIng Stages Sehee Cap&*(CM HaM Input W lorType Width (1-phew) Urmsed Series 9 B 7 M B 42 0B0 C 17 A - A C.Corrm Variahla- 8 Speed 1—c Conshrrt Airlov 0-Base 1.80%Low Nox (VCA)ECM 14=14.2'10 A=1101//BOtte 1=Legacy Una — G Fbord-t;peeds B=23 v:,2=P�� 2.92% ConawTorque 24 24-T 3=Ultra Lev Nox 5.95% (FCTI EC61 24=24.5' 24=800 CFM 8=EVUMon 6•90% 30=1000 CFM 028-28,000 BITJIh V Vedehle-Speed 7 97% M-Maduladng A 38=1200 CFM 040.40,000 BTlJlfr � e 8=9e% ECM S.Single Stage B 42.1400 CFM 080.80,000 BTum T-Two-Slap, C 48.18000FM -- D 80.2000 CFM 88.2200 CFM A190042 For California Residents: For installation in SCAQMD only:This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit,and thus is subject to a mitigation fee of up to$450.This furnace is not eligible for the Clean Air Furnace Rebate Program:www.CleanAirFumaceRebate.com 2 D>Ila/[ED\15l[0NAIL I[DR\AVJI[NG - - - - - - — ellllJJJJJ — I T r I � ii i r4 I I .. N� A190084 A B C D ACCESSORY FILTER TOP AND VENT MEDIA CABINET OUTLET BOTTOM FLUE BOTTOM CONNECTION SHIP WT. CABINET FURNACE SIZE WIDTH WIDTH COLLAR INLET WIDTH SIZE LB(KG) SIZE 36045V14 14-3/16(360) 12-9/16(319) 9-5/16(237) 12-11/16(322) 4(102) 111 (50) 16(406) 36070V14 14-3/16(360) 12-9/16(319) 9-5/16(237) 12-11/16(322) 4(102) 118(54) 16(406) 48070V17 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 132(60) 16(406) 48090V17 17-1/2(445) 15-7/8(403) 11-9/16(294) 16(406) 4(102) 131 (59) 16(406) 60090V21 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 142(64) 20(506) 66110V21 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4(102) 154(70) 20(506) 66135V24 24-1/2(622) 22-7/8(581 15-1/16(383) 23(584) 4(102)* 168(76) 24(610) *135 size furnaces require a 5 or 6—in.(127 or 152 mm)vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for complete installation requirements. 3 SPECIFICATIONS UNIT SIZE 36045V14 3607OV14 4807OV17 4809OV17 6009OV21 6611OV21 66135V24 RATINGS AND PERFORMANCE All Standard High 44,000 66,000 66,000 88,000 88,000 110,000 132,000 Input Btuh* All Low NOx Upflow 7777 29,000 43,500 43,500 58,000 58,000 72,500 87,000 Nonweatherized All Low Nox High 42,000 63,000 63,000 84,000 84,000 105,000 126,000 ICS Downflow/ Horizontal Low 29,000 43,500 43,500 58,000 58,000 72,500 87,000 All Standard High 35,000 53,000 53,000 71,000 71,000 89,000 107,000 Output Capacity All Low NOx Upflow Low 23,000 35,000 35,000 47,000 47,000 59,000 70,000 (Btuh) Nonweatherized All Low Nox High 34,000 51,000 51,000 68,000 68,000 85,000 102,000 ICS^ Downflow/ Horizontal Low 23,000 35,000 35,000 47,000 47,000 59,000 70,000 AFUE 80.00 High 30-60 30-60 25-55 40-70 25-55 30-60 40-70 Certified Temperature Rise Range (17-33) (17-33) (14-30) (22-39) (14-30) (17-33) (22-39) °F('C) Low 20-50 30-60 15-45 30-60 15-45 20-50 25-55 (11-28) (17-33) (8-25) (17-33) (8-25) (11-28) (14-31) Certified External Heat/Cool 0.10/0.50 0.12/0.50 0.12/0.50 0.1510.50 0.15/0.50 0.20/0.50 0.20/0.50 Static Pressure Airflow CFM T Heating High/Low 915/780 1180/715 1400/1225 1380/1005 1800/1570 2055/1685 2075/1795 Cooling 1175 1380 1740 1505 1915 2230 2160 ELECTRICAL Unit Volts-Hertz-Phase 115-60-1 Operating Volt- Min/Max 104/127 age Range Maximum Unit Amps 7.70 8.00 10.50 8.60 11.50 13.10 13.90 Maximum Wire Length(Measure one way in 35(10.9) 34(10.4) 26(8.1) 32(10) 24(7.5) 34(10.4) 32(9.8) Ft.(M)) Minimum Wire Size 14 14 14 14 14 12 12 Maximum Fuse or Ckt Bkr Size(Amps)** 15 15 15 15 15 20 20 Transformer(24v) 40va 40va 40va 40va 40va 40va 40va External Control Heating 12va 12va 12va 12va 12va 12va 12va Power Available ICooling 35va 35va 35va 35va 35va 35va 35va Air Conditioning Blower Relay Standard CONTROLS Burners(Monoport) 2 3 3 4 4 5 6 Gas Connection Size 1/2in.NPT GAS CONTROLS Mfr. WhiteRodgers Gas Valve Min.inlet pressure 4.5(Natural Gas) (Redundant) (In.W.C.) Max.inlet pressure (In.W.C.) 13.6(Natural Gas) Ignition Device Hot Surface Factory installed orifice Size 43 BLOWER DATA Variable-Speed Constant Torque(VCT)ECM 1/2 1/2 3/4 1/2 3/4 1 1 Motor Full Load Amps 6.4 6.7 9.2 6.7 9.6 10.9 11.7 RPM(Nominal) 1200 1200 1200 1200 1200 1200 1200 Blower Wheel Diameter x Width -In.(mm) 10 x 6 10 x 6 11 x 8 10 x 10 11 x 11 11 x 11 11 x1 (27979)(254x152) (254x152) (279x203) (254x254) (279x279) (279x279) * Gas input ratings are certified for elevations to 2000 ft.(610 M). For elevations above 2000 ft.(610 M),reduce ratings 4 percent for each 1000 ft.(305 M) above sea level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1-2012 Table FA or furnace installation instructions. t Capacity in accordance with U.S.Government DOE test procedures. t Airflow shown is for bottom only return-air supply for Max Cooling Airflow and heating airflows(efficiency setting)at certified external static pressure.For air delivery above 1800 CFM,see Air Delivery table for other options.A filter is required for each return-air supply.An airflow reduction of up to 7 percent may occur when using the factory-spec'rfied 4-5/16 in.(110 mm)wide,high efficiency media filter. ** Time-delay type is recommended. ICS Isolated Combustion System 4 ACCESSORIES DESCRIPTION PART NO. 36045V14 3607OV14 4807OV17 480SOV17 6009OV21 6611OV21 66135V24 KGBFRO401 B14 X X External Bottom Return KGBFR0501B17 X X Filter Rack KGBFRO601B21 X X KGBFRO701B24 X KGAWF1306UFR X X X X Unframed Filter 3/4-in. KGAWF1406UFR X X (19 mm) KGAWF1506UFR X Flue Extension KGAFE0112UPH X X X X X X X Combustible Floor Base KGASBO201ALL X X X X X X X Downflow Vent Guard KGBVG0101 DFG X X X X X X X Vent Extension Kit KGAVE0101DNH X X X X X X X KGACA02014FC X X X X X X X Chimney Adapter Kit KGACA02015FC X X Natural-to-Propane AGAGC8NPS01A X X X X X X X Conversion Kit Propane-to-Natural ConversionionKitKit AGAGC8PNS01A X X X X X X X Twinning Kt VCT—ECM Motor AGATWNPME01A X X Switchh Kit High Kft e Pressure KGAHA5801PSW X X X X X X X *Factory-authored and field installed.Fuel conversion kits are CSA(formerly AGA/CGA)recogn¢ed. X=Accessory ORIFICES LH32DB207 LH32DB202 LH32DB200 LH32DB205 LH32DB208 LH32DBO78 See Installation Instructions for model, Gas Orifice LH32DBO76 altitude,and heat value usages. LH32DB203 LH32DB201 LH32DB206 LH32DB209 LH32DB210 5 ACCESSORIES (continued) DESCRIPTION ACCESSORY HUMIDIFIER Model HUM HEAT RECOVERY VENTILATOR Model HRV ENERGY RECOVERY VENTILATOR Model ERV UV LIGHTS Model UVL Bryant has a wide variety of thermostats for your system,please visit www.Bryant.com to see all thermostat and IAQ products. DESCRIPTION ACCESSORY 14" 17" 21" 24" Bryant Carbon Monoxide Alarm(10 pack) COALMBBNRB02—Ai o X X X X Bryant Evolution Air Purifier-16x25(407x635 mm) DGAPAXXI 625 X X Bryant Evolution Air Purifier-20x25(508x635 mm) DGAPAXX2025 X X Bryant Evolution Air Purifier Repl.Filter-16x25(407x635 mm) GAPBBCAR1625-A05 X X Bryant Evolution Air Purifier Repl.Filter-20x25(508x635 mm) GAPBBCAR2025-A05 X X Cartridge Media Filter-16"(407 mm)(MERV 11) FILXXCAR0116 X X Cartridge Media Filter-16"(407 mm)(MERV 8) FILXXCAR0016 X X Cartridge Media Filter-20"(508 mm)(MERV 8) FILXXCAR0020 X Cartridge Media Filter-20"(508 mm)(MERVi 1) FILXXCAR0120 X Cartridge Media Filter-24"(610 mm)(MERV 8) FILXXCAR0024 X Cartridge Media Filter-24"(610 mm)(MERVI1) FILXXCAR0124 X EZ Flex Cabinet Side or Bottom—16" EZXCABCR0016 X X EZ Flex Cabinet Side or Bottom—20" EZXCABCR0020 X X EZ Flex Replacement Filters 16" MERV 10 EXPXXFIL0016 X X EZ Flex Replacement Filters 16" MERV 13 EXPXXFIL0316 X X EZ Flex Replacement Filters 20" MERV 10 EXPXXFIL0020 X EZ Flex Replacement Filters 20" MERV 13 EXPXXFIL0320 X EZ Flex Replacement Filters 24" MERV 10 EXPXXFIL0024 X EZ Flex Replacement Filters 24" MERV 13 EXPXXFIL0324 X EZ-Flex Filter with End Caps-16"(407 mm)(MERV 10) EXPXXUNVO016 X X EZ-Flex Filter with End Caps-16"(407 mm)(MERV 13) EXPXXUNVO316 X X EZ Flex Filter with End Caps-20"(508 mm)(MERV 10) EXPXXUNVO020 X EZ-Flex Filter with End Caps-20"(508 mm)(MERV 13) EXPXXUNVO320 X EZ-Flex Filter with End Caps-24"(610 mm)(MERV 10) EXPXXUNVO024 X EZ-Flex Filter with End Caps-24"(610 mm)(MERV 13) EXPXXUNVO324 X Media Filter Cabinet—20" FILCABXL0020 X Media Filter Cabinet—24" FILCABXL0024 X Media Filter Cabinet—16" FILGABXL0016 X X TYPICAL WIRING SCHEMATIC ----FIELD 24-VOLT WIRING ----FIELD 115-,208/230-,460-VOLT WIRING FACTORY 24-VOLT WIRING FACTORY 115-VOLT WIRING NOTE 2 1-STAGE FIVE w e Y R G THERMOSTAT FIELD-SUPPLIED WIRE I I 1 I I TERMINALS FUSED DISCONNECT I I I I I THREE-WIRE HEATING 208/2&OR ONLY I I - -- --- 460-VOLT THREE BLK• BLK �� PHASE 1 I I I WHT HT con —i-----+----+--F --I -- -- ----- __ w,vu —I-----i i -- -- 208/230 VOLT =GND YN2 NOTE 1__---_i_- { -- --- SINGLE 115-VOLT FIELD JUNCTION I _ _ __ SUPPLIED BOX \J — I i L — PHASE � FUSED CONTROL i CONDENSING DISCONNECT BOX & -------------- UNIT 24-VOLT TERMINAL NOTES:1. Connect Y/Y2-terminal as shown for proper operation. BLOCK 2. Some thermostats require a"C"terminal connection as shown. FURNACE 3. If any of the original wire,as supplied,must be replaced,use same type or equivalent wire. A95236 6 li LI itu I tl �Kl I r •o• SEE NOTES:1,2,4,7,8,9 SEE NOTES: 1,2,3,4,7,8,9 SEE NOTES:1,2,4,5,7,8,9 LIPFLOW UPFLOW DOWNFLOW A02058 A02059 A02061 uuu" I'— i 1�npi + °u oKi i I 1 1 SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES:1,2,4,5,6,7,8,9 DOWNFLOW DOWNFLOW DOWNFLOW A02060 A02063 A02062 Venting Notes 1. For common vent,vent connector sizing and vent material:United States,latest edition of the National Fuel Gas Code(NFGC),ANSI Z223.1/NFPA 54. 2. Immediately increase to 5-in.(127 mm)vent connector outside furnace casing when 5-in.(127 mm)vent connector required,refer to Note 1. 3. Side outlet vent for upflow,and downflow,installations must use Type B vent immediately after exiting the furnace, except when Downflow Vent Guard is used in downflow position. 4. Type B vent where required,refer to Note 1. 5. 4—in.(102 mm)single wall vent must be used inside furnace casing and the Downflow,Vent Guard Kit. 6. Accessory Downflow,Vent Guard Kit,required in downflow installations with bottom vent configuration. 7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing and complete application details. 8. Secure vent connector to furnace elbow with(2)corrosion-resistant sheet metal screws,space approximately 180° apart. 9. Secure all other single wall vent connector joints with(3)corrosion-resistant screws spaced approximately 120' apart. Secure Type B vent connectors per vent connector manufacturer's recommendations. 7 uIfLW O O � I A I, I, SEE NOTES:1,2,4,5,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL RIGHT HORIZONTAL RIGHT A02068 A02070 I' O � I I li ii EI I � I, SEE NOTES:1,2,4,7,8,9 HORIZONTAL RIGHT A02069 �1 W O O I O ► O SEE NOTES: 1,2,4,7,8,9 SEE NOTES:1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02064 A02065 Mal it 0 EPI O p O O .I ,I SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES:1,2,4,5,7,8,9 HORIZONTAL LEFT HORIZONTAL LEFT A02066 A02067 g AIR DELIVERY—CFM (With Filter)* COOLING4 AND HEATING AIR DELIVERY-CFM(Bottom Returns With Filter) (SW1-5 and SW2-2 set to OFF,except as indicated.See notes 1 and 2.) Unit Size:36045V14 Clg/CF Switch settings External Static Pressure(ESP) Clg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Clg Default: OFF OFF OFF 1190 1140 1100 1065 1020 985 905 800 665 525 OFF OFF ON 620 560 520 455 410 355 305 255 See note 4 OFF ON OFF 795 755 705 670 615 585 530 490 440 405 OFF ON ON 1020 955 930 890 840 805 755 715 645 490 Cooling ON OFF OFF 1190 1 1140 1100 1065 1020 985 905 800 665 525 (SW2-8,7,6) ON OFF ON 1455 1390 1325 1255 1175 1085 1000 880 755 575 ON ON OFF 1455 1390 1325 1255 1175 1085 1000 880 755 575 ON ON ON 1455 1390 1325 1255 1175 1085 1000 880 755 575 Maximum Clg AirflOW2 1455 1390 1325 1255 1175 1085 1000 880 755 575 CF Switches SW2-5 SW2-4 SW2-3 Low-Clg Default: OFF OFF OFF 620 560 520 455 410 355 305 255 See note 4 OFF OFF ON 620 560 520 455 410 355 305 255 See note 4 OFF ON OFF 795 755 705 670 615 585 530 490 440 405 Low-Cooling OFF ON ON 1020 955 930 890 840 805 755 715 645 490 (SW2-5,4,3) ON OFF OFF 1190 1140 1100 1065 1020 985 905 800 665 525 ON OFF ON 1455 1390 1325 1255 1175 1085 1000 880 755 575 ON ON OFF 1455 1390 1325 1255 1 1175 1 1085 1000 1 880 755 575 ON ON ON 1455 1390 1325 1255 1 1175 1 1085 1000 1 880 755 575 Cont.Fan Default: OFF OFF OFF 620 560 520 455 410 355 305 255 See note 4 OFF OFF ON 620 560 520 455 410 355 305 255 See note 4 OFF ON OFF 795 755 705 670 615 585 530 490 440 405 Continuous Fan OFF ON ON 1020 955 930 890 840 805 755 715 645 490 (SW2-5,4,3) ON OFF OFF 1020 955 930 890 840 805 755 715 645 4.90 ON OFF ON 1020 955 930 890 840 805 755 715 645 490 ON ON OFF 1020 955 930 890 1 840 1 805 755 715 645 490 ON ON ON 1020 955 930 890 840 1 805 755 715 645 490 Heating High Heat Airflow3 915 860 825 790 735 700 650 610 550 450 (SW1) Low Heat Airflow3 780 730 685 635 585 545 495 450 400 370 Unit Size:36070V14 Clg/CF Switch settings External Static Pressure(ESP) Clg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Clg Default: OFF OFF OFF 1155 1125 1095 1065 1035 1005 975 950 915 875 OFF OFF ON 605 555 500 440 375 320 265 See note 4 OFF ON OFF 775 735 690 650 600 550 500 450 405 365 OFF ON ON 980 950 915 880 845 810 775 735 695 655 Cooling ON OFF I OFF 1155 1125 1095 1065 1035 1 1005 975 1 950 915 875 (SW2-8,7,6) ON OFF ON 1370 1340 1310 1285 1260 1235 1210 1140 1025 880 ON ON OFF 1505 1480 1455 1420 1380 1335 1250 1155 1045 900 ON ON ON 1505 1480 1455 1420 1380 1335 1250 1155 1045 900 Maximum Clg Airflow 1505 1480 1455 1 1420 1380 4- 1250 1155 1045 900 CF Switches SW2-5 SW24 SW2-3 Low-Clg Default: OFF OFF OFF 605 555 500 440 375 320 265 See note 4 OFF OFF ON 605 555 500 440 375 320 265 See note 4 OFF ON OFF 775 735 690 650 600 550 500 450 405 365 OFF ON ON 980 950 915 880 845 810 775 735 695 655 Low-Cooling(SW2-5,4,3) ON OFF OFF 1155 1125 1095 1065 1035 1005 975 950 915 875 ON OFF ON 1370 1340 1310 1285 1260 1235 1210 1140 1025 880 ON ON OFF 1505 1480 1455 1420 1380 1335 1250 1155 1045 900 ON ON ON 1505 1480 1455 1420 1380 1335 1250 1155 1045 900 Cont.Fan Default: OFF OFF OFF 605 555 500 440 375 320 265 See note 4 OFF OFF ON 605 555 500 440 375 320 265 See note 4 OFF ON OFF 775 735 690 650 600 550 500 450 405 365 Continuous Fan OFF ON ON 980 950 915 880 845 810 775 735 695 655 (SW2-5,4,3) ON OFF OFF 1155 1125 1095 1065 1035 1005 975 950 915 875 ON OFF ON 1370 1340 1310 1285 1260 1235 1210 1140 1025 880 ON ON OFF 1370 1340 1310 1 1285 1260 1235 1210 1 1140 1025 880 ON ON ON 1370 1 1340 1310 1 1285 1260 1235 1210 1140 1025 880 Heating High Heat Airflow 1190-T 1160 F1130 1100 1 1070 1045 1015 985 955 900 (SW1) Low Heat Airflow3 725 1 680 1 635 585 1 530 475 425 375 330 285 9 AIR DELIVERY—CFM (With Filter)* (Continued) COOLING4 AND HEATING AIR DELIVERY-CFM(Bottom Return5 With Filter) (SW1-5 and SW2-2 set to OFF,except as indicated.See notes 1 and 2.) Unit Size:48070V17 Clg/CF Switch settings External Static Pressure(ESP) Gig Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1 0.9 1.0 Gig Default: OFF OFF OFF 1600 1570 1535 1500 1465 1430 1400 1365 1 1335 1300 OFF OFF ON 590 520 440 365 300 235 See note 4 OFF ON OFF 790 730 670 610 550 485 430 380 330 275 OFF ON ON 1025 980 930 880 835 785 735 690 635 590 Cooling ON OFF OFF 1230 1 1190 1150 1105 1065 1025 980 940 900 860 (SW2-8,7,6) ON OFF ON 1390 1355 1315 1280 1240 1200 1165 1125 1090 1055 ON ON OFF 1600 1570 1535 1500 1465 1430 1400 1365 1335 1300 ON ON ON 1855 1830 1800 1770 1740 1695 1645 1600 1520 1415 Maximum Gig Airflow2 1855 1830 1800 1770 1740 1695 1645 1600 1 1520 1415 CF Switches SW2-5 SW2-4 SW2-3 Low-Cig Default: OFF OFF OFF 590 520 440 365 300 235 See note 4 OFF OFF ON 590 520 440 365 300 235 See note 4 OFF ON OFF 790 730 670 610 550 485 430 380 330 275 OFF ON ON 1025 980 930 880 835 785 735 690 635 590 Low-Cooling ON OFF OFF 1230 1190 1150 1105 1065 1025 980 940 900 860 (SW2-5,4,3) ON OFF ON 1390 1355 1315 1280 1240 1200 1165 1125 1090 1055 ON ON OFF 1600 1570 1535 1500 1465 1430 1400 1365 1335 1300 ON ON ON 1855 1830 1800 I 1770 I 1740 1695 1645 1600 1520 1415 Cont.Fan Default: OFF OFF OFF 590 520 440 365 300 235 See note 4 OFF OFF ON 590 520 440 365 300 235 See note 4 OFF ON OFF 685 625 565 505 445 385 325 265 See note 4 OFF ON ON 790 730 670 610 550 485 430 380 330 275 Continuous Fan(SW2-5,4,3) ON OFF OFF 790 730 670 610 550 485 430 380 330 275 ON OFF ON 790 730 670 610 550 485 430 380 330 275 ON ON OFF 790 730 670 610 550 485 430 380 330 275 ON ON I ON 790 730 670 610 550 485 430 380 330 275 Heating High Heat Airflow3 1410 1375 1 1340 1300 1260 1225 1 1190 1 1155 1120 1085 (SW1) Low Heat Airflow3 1235 1195 1 1155 1110 1070 1025 1 985 1 945 1 905 1 865 Unit Size:48090V17 Clg/CF Switch settings External Static Pressure(ESP) Gig Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1 0.9 1.0 Gig Default: OFF OFF OFF 1560 1520 1485 1450 1415 1380 1340 1300 1 1260 1115 OFF OFF ON 680 605 495 415 345 275 See note 4 OFF ON OFF 835 770 700 600 535 465 410 350 285 240 OFF ON ON 1035 980 930 870 795 720 665 605 555 505 Cooling ON OFF OFF 1210 1165 1125 1080 1030 975 905 845 790 740 (SW2-8,7,6) ON OFF ON 1375L1335 1300 1260 1220 1175 1125 1075 1010 955 ON ON OFF 1560 1485 1450 1415 1380 1340 1300 1260 1115 ON ON ON 1640 1570 1540 1505 1470 1435 1390 1325 1110 Maximum Clg Airflow 1640 1570 1540 1505 1470 1435 1390 1325 1110 CF Switches SW2-5 SW2-4 SW2-3 Low-Clg Default: OFF OFF OFF 680 605 495 415 345 275 See note 4 OFF OFF ON 680 605 495 415 345 275 See note 4 OFF ON OFF 835 770 700 600 535 465 410 350 285 240 OFF ON ON 1035 980 930 870 795 720 665 605 555 505 Low-Cooling(SW2-5,4,3) ON OFF OFF 1210 1165 1125 1080 1030 975 905 845 790 740 ON OFF ON 1375 1335 1300 1260 1220 1175 1125 1075 1010 955 ON ON OFF 1560 1520 1485 1450 1415 1380 1340 1300 1260 1115 ON ON ON 1640 1605 1570 1540 1505 1470 1435 1390 1325 1110 Cont.Fan Default: OFF OFF OFF 680 605 495 415 345 275 See note 4 OFF OFF ON 680 605 495 415 345 275 See note 4 OFF ON OFF 835 770 700 600 535 465 410 350 285 240 OFF ON ON 1035 980 930 870 795 720 665 605 555 505 Continuous Fan(SW2-5,4,3) ON OFF OFF 1210 1165 1125 1080 1030 975 905 845 790 740 ON OFF ON 1375 1335 1300 1260 1220 1175 1125 1075 1010 955 ON ON OFF 1560 1520 1485 1450 1415 1380 1340 1300 1260 1115 ON ON ON 1560 1520 1485 1450 1415 1380 1340 1300 1260 1115 Heating High Heat Airflow3 1400 1360 1325 1285 1245 1200 1155 1110 1045 995 (SW1) Low Heat Airflow3 1035 980 930 870 795 720 665 605 555 505 10 AIR DELIVERY—CFM (With Filter)* (Continued) COOLING4 AND HEATING AIR DELIVERY-CFM(Bottom Return With Filter) (SW1-5 and SW2-2 set to OFF,except as indicated.See notes 1 and 2.) Unit Size:60090V21 Clg/CF Switch settings External Static Pressure(ESP) Clg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1 0.9 1 1.0 Clg Default: OFF OFF OFF 1985 1935 1885 1835 1785 1735 1685 1630 1 1583 1 1532 OFF OFF ON 860 755 650 545 445 350 235 See note 4 OFF ON OFF 1085 1000 910 830 735 655 565 485 405 310 OFF ON ON 1255 1180 1105 1025 950 870 790 715 640 570 Cooling ON OFF OFF 1425 1355 1290 1220 1150 1085 1015 940 870 800 (SW2-8,7,6) ON OFF ON 1630 1575 1515 1455 1395 1330 1270 1210 1155 1090 ON ON OFF 1985 1935 1885 1835 1785 1735 1685 1630 1583 1532 ON ON ON 2100 2055 2010 1960 1915 1870 1820 1775 1715 1640 Maximum Clg Airflow2 2100 2055 2010 1960 1915 8870 1820 1775 1 1715 1 1640 CF Switches SW2-5 SW24 SW2-3 Low-CIg Default: OFF OFF OFF 860 755 650 545 445 350 235 See note 4 OFF OFF ON 700 575 455 345 225 See note 4 OFF ON OFF 860 755 650 545 445 350 235 See note 4 OFF ON ON 1085 1000 910 830 735 655 565 485 405 310 Low-Cooling(SW2-5,4,3) ON OFF OFF 1255 1180 1105 1025 950 870 790 715 640 570 ON OFF ON 1425 1355 1290 1220 1150 1085 1015 940 870 800 ON ON OFF 1630 1575 1515 1455 1395 1330 1270 1210 1155 1090 ON ON ON 1985 1935 1885 I 1835 1 1785 1735 1685 1630 1583 1532 Cont.Fan Default: OFF OFF I OFF —8-6-07 755 650 545 445 350 235 1 See note 4 OFF OFF ON 700 575 455 345 225 See note 4 OFF ON OFF 860 755 650 545 445 350 235 See note 4 OFF ON ON 1085 1000 910 830 735 655 565 485 405 310 Continuous Fan ON OFF OFF 1255 1180 1105 1025 950 870 790 715 640 570 (SW2-5,4,3) ON OFF ON 1255 1180 1105 1025 950 870 790 715 640 570 ON ON OFF 1255 1180 1105 1025 950 870 790 715 640 570 ON I ON ON 1255 T 1180 1 1105 1025 950 870 790 715 640 570 Heating High Heat Airflow3 1830 1775 1725 1675 1625 1 1570 1 1520 1 1465 1410 1360 (SW1) Low Heat Airflow 1600 1540 1485 1 1430 1370 1 1315 1 1255 1 1195 1140 1070 Unit Size:66110V21 Clg/CF Switch settings External Static Pressure(ESP) Clg Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0A 0.5 0.6 0.7 0.8 0.9 1.0 Clg Default: OFF OFF OFF 2055 2000 1950 1900 1 1840 1790 1740 1 1675 1625 1565 OFF OFF ON 855 755 See note 4 OFF ON OFF 1060 985 875 800 700 See note 4 OFF ON ON 1250 1180 1095 1025 925 860 775 715 See note 4 Cooling ON OFF OFF 1 1445 1380 1 1320 1235 1175 1100 1035 955 900 825 (SW2-8,7,6) ON OFF ON 1685 1630 1560 1505 1445 1375 1320 1265 1195 1140 ON ON OFF 2055 2000 1950 1900 1840 1790 1740 1675 1625 1565 ON ON ON 2465 2415 2365 2305 2230 2140 2045 1925 1805 1655 Maximum CIg Airflow 2465 2415 2365 2305 2230 2140 2045 1925 1805 1655 CF Switches SW2-5 SW24 SW2-3 Low-Clg Default: OFF OFF OFF 855 755 See note 4 OFF OFF ON 640 540 See note 4 OFF ON OFF 855 755 See note 4 OFF ON ON 1060 985 875 800 700 See note 4 Low-Cooling ON OFF OFF 1250 1180 1095 1025 925 860 775 715 See note 4 (SW2-5,4,3) ON OFF ON 1445 1380 1 1320 1235 1175 1100 1035 955 900 825 ON ON OFF 1685 1630 1 1560 1505 1445 1375 1320 1265 1195 1140 ON ON ON 2055 2000 1 1950 1900 1840 1790 1740 1675 1625 1565 Cont.Fan Default: OFF OFF OFF 855 755 See note 4 OFF OFF ON 640 540 See note 4 OFF ON OFF 855 755 See note 4 Continuous Fan OFF ON ON 1060 985 875 800 700 See note 4 (SW2-5,4,3) ON OFF OFF 1250 1180 1095 1025 925 860 1 775 715 See note 4 ON OFF ON 1445 1380 1320 1235 1175 1100 1 1035 955 900 825 ON ON OFF 1445 1380 1320 1235 1175 1100 1035 955 900 825 ON ON ON 1445 1380 1320 1235 1175 1100 1035 955 900 825 Heating High Heat Airflow 2105 2055 2005 1955 1895 1850 1795 1735 1665 1580 (SW1) Low HeatAirflow3 1740 1685 1620 1560 1505 1440 1385 1325 1260 1205 11 AIR DELIVERY—CFM (With Filter)* (Continued) COOLING4 AND HEATING AIR DELIVERY-CFM(Bottom ReturnO With Filter) (SW1-5 and SW2-2 set to OFF,except as indicated.See notes 1 and 2.) Unit Size:66135V24 Clg/CF Switch settings External Static Pressure(ESP) Gig Switches: SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1 0.9 1.0 Clg Default: OFF OFF OFF 2105 2050 1995 1940 1880 1820 1765 1705 1 1650 1590 OFF OFF ON 990 885 780 665 570 See note 4 OFF ON OFF 1180 1090 995 900 815 715 635 555 475 400 OFF ON ON 1355 1270 1190 1105 1020 940 855 775 700 630 Cooling ON OFF OFF 1535 1 1465 1395 1 1320 1245 1165 1095 1025 945 875 (SW2-8,7,6) ON OFF ON 1735 1670 1605 1535 1470 1405 1335 1270 1205 1140 ON ON OFF 2105 2050 1995 1940 1880 1820 1765 1705 1650 1590 ON ON ON 2280 2225 2175 2120 2065 2010 1955 1905 1850 1800 Maximum Clg Airflow 2360 2310 2265 2215 2160 2115 2060 2010 1960 1870 CF Switches SW2-5 SW2-4 SW2-3 Low-Clg Default: OFF OFF OFF 990 885 780 665 570 See note 4 OFF OFF ON 800 670 540 410 280 See note 4 OFF ON OFF 990 885 780 665 570 See note 4 OFF ON ON 1180 1090 995 900 815 715 635 555 475 400 Low-Cooling(SW2-5,4,3) ON OFF OFF 1355 1270 1190 1105 1020 940 855 775 700 630 HON OFF ON 1535 1465 1395 1320 1245 1165 1095 1025 945 875 N N ON OFF 1735 1670 1605 1535 1470 1405 1335 1270 1205 1140 ON ON 2105 2050 1995 1940 1880 1820 1765 1705 1650 1590 Cont.Fan Default: OFF OFF OFF 740 605 470 360 255 See note 4 OFF OFF ON 740 605 470 360 255 See note 4 OFF ON OFF 900 775 650 525 400 See note 4 Continuous Fan OFF ON ON 1080 980 885 785 680 595 510 430 345 260 (SW2-5,4,3) ON OFF OFF 1080 980 885 785 680 595 510 430 345 260 ON OFF ON 1080 980 885 785 680 595 510 430 345 260 ON ON OFF 1080 980 885 785 680 T595 510 430 345 260 ON ON I ON 1080 1 980 885 785 680 1 595 510 430 345 260 Heating High Heat Airflow 2130 2075 1 2020 1 1970 1910 1855 1805 1745 1690 1630 (SW1) I Low HeatAirflow3 1855 1 1795 1 1730 1 1670 1605 1545 1480 1420 1360 1300 1. Nominal 350 CFM/ton cooling airflow is delivered with SW1-5 and SW2-2 set to OFF. Set both SW1-5 and SW2-2 to ON for+7%airflow(nominal 370 CFM/ton). Set SW1-5 to ON and SW2-2 to OFF for+15%airflow(nominal 400 CFM/tan). Set SW2-2 to ON and SW1-5 to OFF for-7%airflow(nominal 325 CFM/ton). The above adjustments in airflow are subject to motor horsepower range/capacity. This applies to Cooling and Low-Cooling airflow,but does not affect continuous fan airflow. 2. Maximum cooling airflow is achieved when switches SW2-6,SW2-7,SW2-8 and SW1-5 are set to ON,and SW2-2 is set to OFF. 3. All heating CFM's are when comfort/efficiency adjustment switch(SW1-4)is set to OFF 4. Ductwork must be sized for high-heating CFM within the operational range of ESP. Operation within the blank areas of the chart is not recommended because high-heat operation will be above 1.0 ESP. 5. All airflows on 21"casing size furnaces are 5%less on side return only installations. 6. Side returns for 24.5"casing sizes require two sides,or side and bottom,to allow sufficient airflow at the return of the furnace. 7. Airflows over 1800 CFM require bottom return,two-side return, or bottom and side return or excessive watt draw may result.A minimum filter size of 20x25"(508 x 635 mm)is required. 12 A WARNING INSTALLATION FIRE,EXPLOSION, MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION ASPHYXIATION HAZARD This forced air furnace is This furnace is approved for equipped for use with natural UPFLOW, DOWNFLOW, and Improper adjustment,alteration,service, gas at altitudes 0- 10,000 ft HORIZONTAL installations. maintenance,or installation can cause (0 -3,050m). Clearance arrows serious injury or death. An accessorykit lied b r i do not change with , supplied Y � furnace orientation. the manufacturer, shall be used w Read and follow instructions and to convert to propane gas use precautions in User's Information Manual or may be required for some ° BA provided with this furnace. Installation natural gas applications. �K Pc� and service must be performed by a This furnace is for indoor qualified service agency or the gas installation in a building F� SERV'supplier. constructed on site, of F CE This furnace may be installed s RONT �^m ACAUTION on combustible flooring in alcove *°"or closet at minimum clearance o o, o Check entire gas assembly for leaks after as indicated by the diagram m lighting this appliance. from combustible material. This furnace may be used with t Clearance in inches INSTALLATION a Type B-1 Vent and may be Vent Clearance to combustibles: 1.This furnace must be installed in vented in common with other For Single Wall vents 6 inches(6 po). accordance with the manufacturer's gas fired appliances. For Type B-1 vent type 1 inch(1 po). instructions and local codes. In the absence of local codes,follow the National MINIMUM INCHES CLEARANCE TO Fuel Gas Code ANSI Z223.1 /NFPA54 COMBUSTIBLE CONSTRUCTION or CSA B-149. 1 Gas Installation Code. 2.This furnace must be installed so there are DOWNFLOW POSITIONS: provisions for combustion and ventilation air. See manufacturer's installation t Installation on non-combustible floors only. information provided with this appliance. For Installation on combustible flooring only when installed on special base, Part No. KGASB0201ALL or NAHA01101SB, Coil Assembly, OPERATION Part No.CAR,CAP,CNPV,CNRV,END4X,ENW4X,WENC,WTNC, This furnace is equipped with manual reset WENW OR WTNW. limit switch(es)in burner compartment to 0 18 inches front clearance required for alcove. protect against overheat conditions that can result from inadequate combustion air * Indicates supply or return sides when furnace is in the horizontal supply or blocked vent conditions. position. Line contact only permissible between lines formed by 1. Do not bypass limit switches. intersections of the Top and two Sides of the furnace jacket, 2. If a limit opens, call a quallified and building joists,studs or framing. ul�ll I�II�IIIII I�I III�I II IIIII II IIII serviceman to correct the condition and reset limit switch. 336996-101 REV.C A10269 13 GUIDE SPECIFICATIONS Gas Furnace Casine 820TA/821TA Casing shall be of .030 in. (.76 mm) thickness minimum, General pre-painted steel. Two Speed Inducer Motor SYSTEM DESCRIPTION Two Speed Inducer motor shall be soft mounted to reduce Furnish a fixed capacity gas-fired furnace for vibration transmission. use with natural gas or propane(factory authorized conversion kit Draft Safeguard Switch required for propane);furnish cold air return plenum. QUALITY ASSURANCE Draft Safeguard Switch (blocked vent safeguard) shall be factory installed to reduce the possibility of vent gas infiltration due to a Unit will be designed,tested and constructed to the current ANSI Z blocked or restricted vent pipe. 21.47/CSA 2.3 design standard for gas-fired central furnaces. Heat Exchaneers Unit will be 3rd party certified by CSA to the current ANSI Z Heat exchangers shall be a 4-Pass 20 gage aluminized steel of 21.47/CSA 2.3 design standard for gas-fired central furnaces, fold-and-crimp sectional design when applied operating under Unit will carry the CSA Blue Star®label. negative pressure. Unit efficiency testing will be performed per the current DOE test Controls procedure as listed in the Federal Register. Control shall include a micro-processor based integrated electronic Unit will be certified for capacity and efficiency and listed in the control board with at least 11 service troubleshooting codes latest AHRI Consumer's Directory of Certified Efficiency Ratings. displayed via diagnostic flashing enhanced LED light on the Unit shall carry the current Federal Trade Commission Energy control, a self-test feature that checks all major functions of the Guide efficiency label. furnace within one minute, and a replaceable automotive-type DELIVERY,STORAGE AND HANDLING circuit protection fuse. Multiple operational settings available Unit shall be shipped as single package only and is stored and including, separate blower speeds for low heat, high heat, low handled per unit manufacturer's recommendations. cooling, high cooling and continuous fan. Continuous fan speed may be adjusted from the thermostat. Cooling airflow will be WARRANTY(for inclusion by specifying engineer) selectable between 350 or 400 CFM per ton of air conditioning. U.S.only.Warranty certificate available upon request. Features will also include temporary reduced airflow in the cooling Products mode for improved dehumidification when a control or Thermidistat' is selected as the thermostat. EQUIPMENT OPERATING CHARACTERISTICS Components shall include: slow-opening two stage gas valve to Heating Capacity shall be Btuh input; Btuh reduce ignition noise, regulate gas flow, with electric switch gas output capacity. shut-off;flame proving sensor,hot surface igniter,pressure switch assembly,flame rollout switch,blower and inducer assembly,40va Fuel Gas Efficiency shall be 80%AFUE. transformer;low-voltage(heating)(heating/cooling)thermostat. Air delivery shall be CFM minimum at 0.50 in. Blower Wheel and Blower Motor W.C.external static pressure. Galvanized blower wheel shall be centrifugal type, statically and Dimensions shall be: depth in. (mm); width dynamically balanced. Blower motor of ECM type shall be in. (mm); height in. (mm). (casing only). permanently lubricated with sealed bearings, of hp, and Height shall be in. (mm). with A/C coil and shall be multiple-speed direct drive. Blower motor shall be soft in.(mm)overall with plenum. mounted to the blower scroll to reduce vibration transmission. ELECTRICAL REQUIREMENTS Filters Electrical supply shall be 115 volts,60 Hz,single-phase(nominal). Furnace may have reusable-type filters.Filter shall be (x) Minimum wire size shall be AWG;maximum fuse size in. (mm). An accessory high efficiency Media Filter is or circuit breaker shall be Amps. available as an option. Media Filter. SPECIAL FEATURES Refer to section of the product data sheet identifying accessories and descriptions for specific features and available enhancements. ©2019 Bryant Heating&Cooling Systems 7310 W.Morris St. Indianapolis,IN 46231 Edition Date:3/19 Catalog No.PDS820TA-01 anu ac urer reserves the right o discontinue,or change at any time,specitications or designs vAthout notice and vAthout mcurnng obligations. Replaces: NEW 14 Permit#: 2831 Permit Date: 10/07/19 Permit Type: RESIDENTIAL MECHANICAL Project Name: Young Applicant Name: Day and Nite Plumbing and Heating Applicant Address: 16614 13th Ave W. Applicant, City, State, Zip: Lynnwood, WA 98037 Contact: Phone: 425-775-6464 Email: bryan@dayandnite.net Scope of Work: Replace gas furnace Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 10/08/2019 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00411700701900 437 S OLYMPIC AVE YOUNG HEIDI 111 Single Family Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# Day&Nite Plumbing& 16614 13th Ave CONSTRUCTION Construction DAYNINP789D5 Heating,Inc Bryan Radcliff 425-775-6464 w CONTRACTOR Contractor Fees Fee Description Notes Amount Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Total $75.00 Attached Letters Date Letter Description 10/07/2019 Building Permit 10/07/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 10/08/2019 Bruce Davis 77423166 $75.00 Outstanding Balance $0.00 Notes Date Note Created By: 10/07/2019 Emailed contractor for business license Raelynn Jones Uploaded Files Date File Name 10/07/2019 5 71942 5-attachments C015031000017664944 LcL4p3CrRTdS00B02SkdJ Product+Date+Sheet.pdf 10/07/2019 5719423-2831 Application.pdf