HomeMy WebLinkAbout505 E 3RD STREET_BLD3291_2026 NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY E'APPROVED PERMIT#: I AM PM DATE: JOB ADDRESS: b 5 E :„ LOT#: PROJECT: TYPE OF INSPECTION: OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 '-/-.-)5-d oDo INSPECTOR DATE Cl PLANNING Cl CIVIL Cl BUILDING CITY OF ARLINGTON CITY OF ARLINGTON 18204 59th Avenue NE,Arlington, WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 505 E Third Street NE Permit#:3291 Permit Expiration Date: 12/28/2020 Parcel#: 31050200401500 Valuation:2119.00 OWNER APPLICANT CONTRACTOR ARLINGTON SCHOOL DISTRICT 16 Commercial Fire Protection,Inc. Commercial Fire Protection,Inc 315 N FRENCH AVENUE 17199 Bennett Rd 17199 Bennett Rd ARLINGTON,WA 98223 Mount Vernon,WA 98273 Mount Vernon,WA 98273 360-848-9093 ext113 360-848-9093 LIC:COMMEFP132MM EXP:08/I6/2020 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Sprinkler CODE YEAR: 2015 STORIES: 1 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of,any violation of this Code or any other ordinance or order of the City, of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRCI 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. aaoM q, by ON Wk4 w Della Dellinger W.UE Della Dellinger 7/16/2 as 7 � � Signature Print Name Date cleased By l Dat CONDITIONS 1. Permit and set of approved plans to remain on site during installation. 2. Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections; may include hangers,earthquake bracing, sprinkler locations and pipe re-rousing that could impact hydraulic calculations.Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted.3. Hangers and earthquake bracing shall be installed in accordance with NFPA 13.4.Relocated EC sprinkler shown on drawing appears to be greater than maximum allowed distance from north wall of classroom.5.Hydrostatic test required:working pressure for 2 hours minimum 6.Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit.7.Owner shall be provided with a set of approved plans and associated documents for their files. 8.Adhere to approved plans.9.Approved job copy shall be onsite for inspections. 10.Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 07/16/2020 Fire Sprinkler Permit $75.00 07/16/2020 Processing(Technology Fee $25.00 07/16/2020 Fire System Plan Review $100.00 07/16/2020 Credit Card Surcharga $6.00 Total Due: $206.00 Total Payment: $206.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON ` 18204 59th Avenue NE,Arlington, WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT Permit#:3291 505 E Third Street NE Permit Expiration Date: 12/28/2020 Parcel#: 31050200401500 Valuation: 2119.00 OWNER APPLICANT CONTRACTOR ARLINGTON SCHOOL DISTRICT 16 Commercial Fire Protection,Inc. Commercial Fire Protection,Inc 315 N FRENCH AVENUE 17199 Bennett Rd 17199 Bennett Rd ARLINGTON,WA 98223 Mount Vernon,WA 98273 Mount Vernon,WA 98273 360-848-9093 ext 113 360-848-9093 LIC:COMMEFP132MM EXP:08/16/2020 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Sprinkler CODE YEAR: 2015 STORIES: 1 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: i OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date eleased By tl bat CONDITIONS 1. Permit and set of approved plans to remain on site during installation.2. Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections: may include hangers,earthquake bracing, -� I sprinkler locations and pipe re-rout' )hat could impact hydraulic calculations.Failt submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 3. Hangers and earthquake bracing shall be installed in accordance with NFPA 13.4. Relocated EC sprinkler shown on drawing appears to be greater than maximum allowed distance from north wall of classroom. 5.Hydrostatic test required:working pressure for 2 hours minimum 6. Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit. 7.Owner shall be provided with a set of approved plans and associated documents for their files. 8.Adhere to approved plans. 9. Approved job copy shall be onsite for inspections. 10. Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 07/16/2020 Fire Sprinkler Permit $75.00 07/16/2020 Processing/Technology Fee $25.00 07/16/2020 Fire System Plan Review $100.00 07/16/2020 Credit Card Surcharge $6.00 Total Due: $206.00 Total Payment: $206.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON ` 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 505 E Third Street NE Permit#: 3291 Permit Expiration Date: 12/28/2020 Parcel#: 31050200401500 Valuation: 2119.00 OWNER APPLICANT CONTRACTOR ARLINGTON SCHOOL DISTRICT 16 Commercial Fire Protection, Inc. Commercial Fire Protection,Inc 315 N FRENCH AVENUE 17199 Bennett Rd 17199 Bennett Rd ARLINGTON,WA 98223 Mount Vernon,WA 98273 Mount Vernon,WA 98273 360-848-9093 ext113 360-848-9093 LIC:COMMEFP132MM EXP:08/16/2020 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: A& JOB DESCRIPTION PERMIT TYPE: Fire Sprinkler CODE YEAR: STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: MEW PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law, or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/iRCI 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. � l3 Signature Print Name Date Released By bate CONDITIONS 1.Permit and set of approved plans to remain on site during installation. 2. Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections: may include hangers,earthquake bracing, sprinkler locations and pipe re- ',ng that could impact hydraulic calculations.F`)e to submit revisions could result in cancellation of an inspection while..review of an as-built resubmittal is conducted. 's.riangers and earthquake bracing shall be installed in accordance with NFPA 13.4. Relocated EC sprinkler shown on drawing appears to be greater than maximum allowed distance from north wall of classroom. 5.Hydrostatic test required:working pressure for 2 hours minimum 6. Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit.7.Owner shall be provided with a set of approved plans and associated documents for their files. 8.Adhere to approved plans. 9.Approved job copy shall be onsite for inspections. 10.Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PEWMIT FEES Date Description Fee Amount 07/13/2020 Fire Sprinkler Permit $75.00 07/13/2020 Processing/Technology Fee $25.00 07/13/2020 Fire System Plan Review $100.00 Total Due: $200.00 Total Payment: $0.00 Balance Due: $200.00 C':kl,L FOR INSFEMOIiS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon i �., :! 4 • Permit#: 3291 Permit Date: 07/01/20 Project Name: Arlington School District Site Address: 505 E Third Street NE Company/Applicant Name: Commercial Fire Protection, Inc. Company/Applicant Address: 17199 Bennett Rd City, State, Zip: Mount Vernon, WA 98273 Contact: Della Dellinger Phone: 360-848-9093 ext 113 Email: della@cfirepro.com Permit Type: Fire Sprinkler Valuation: 2119.00 Square Feet: 40 Number of Stories: 0 Type of Construction: Occupancy Type: Scope of Work: Sprinkler relocation MIC/Opportunity Zone: Permit Issued: Permit Expires: 12/28/2020 DNU: Status: IN PROCESS Property Parcel# Address Legal Description Owner Name Owner Phone Zoning ARLINGTON 31050200401500 505 E 3RD STREET SCHOOL DISTRICT 16 Contractors Contractor Primary Contact Phone Address Contractor Type License License# Commercial Fire Della L Dellinger 360-848-9093 17199 Bennett Rd CONTRACTOR Labor& COMMEFP132MM Protection,Inc Industries Plan Reviews Date Review Type Description Assigned To Review Status 07/01/2020 Fire Sprinkler Building In Review 07/01/2020 Fire Sprinkler Mike Makela In Review " :. � _ 4� I 1 Fees Fee Description Notes Amount Fire Sprinkler Permit Commercial NFPA 13/13R $75.00 Processing/Technology Fee $25.00 Fire System Plan Review Table 4-2 or 4-10 $100.00 Total $200.00 Uploaded Files Date File Name 07/01/2020 6917282-3291 Plans.pdf 07/01/2020 6917283-3291 ApplicatiMp-d c� 1"NK4 r FIRE SPRINKLER PERMIT APPLICATION Department of Community &Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF COMPLETE AND SCALED PLANS, TWO (2) SETS OF HYDRAULIC CALCULATIONS, TWO (2) SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE SPRINKLER PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION. Type of Permit: ❑ New Fire Sprinkler ❑✓ Fire Sprinkler Add/Alt ❑ Underground Fire Line Project Address: 505 E. 3rd St. Parcel ID#: Project Valuation: 2119.00 Number of Heads: 1 Building Area(Sq Ft) 40 Owner: Arlington School District #16 Phone Number: 360 631-3116 Address: 135 S. French Ave City:Arlington State: WA Zip Code: 98223 Contact Person:Mark Webb Phone Number: 360 631-3116 Cell Phone: 360 631-3116 Email: mwebb@asd.wednet.edu Address: 17199 Bennett Rd City: Mount Vernon State: WA Zip Code:98273 Contractor: Commercial Fire Protection, Inc. Phone Number: 360 848-9093 EXT113 Address: 17199 Bennett Rd. City: Mount Vernon State: WA Zip Code:98273 Contractor's License Number: COMMEFP132MM Expiration:08/16/20 Contact Person: Della Dellinger Email:della@cfirepro.com hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described roperty will be in accordance with the laws,rules and regulation of the State of Washington. �P,ll.2�elf�sr�e� j 06/30/2020 Applicants Signature Date Della Dellinger Print Applicants Name / FOR STAFF USE ONLY Receivem J U N 3 0 2020 Permit# Acce By Amount Received Receipt# Date Received WEB Forms—131 Page 1 of 1 6/16LP i I -, �� � I Permit#: 3291 Permit Date: 07/01/20 Project Name: Arlington School District Site Address: 505 E Third Street NE Company/Applicant Name: Commercial Fire Protection, Inc. Company/Applicant Address: 17199 Bennett Rd City, State, Zip: Mount Vernon, WA 98273 Contact: Della Dellinger Phone: 360-848-9093 ext 113 Email: della@cfirepro.com Permit Type: Fire Sprinkler Valuation: 2119.00 Square Feet: 40 Number of Stories: 0 Type of Construction: Occupancy Type: Scope of Work: Sprinkler relocation MIC/Opportunity Zone: Permit Issued: Permit Expires: 12/28/2020 DNU: Status: W PROCESS Property Parcel# Address Legal.Description Owner Name Owner Phone Zoning ARLINGTON 31050200401500 505 E 3RD STREET SCHOOL DISTRICT 16 Contractors Contractor Primary Contact Phone Address Contractor Type License License# Commercial Fire Della L Dellinger 360-848-9093 17199 Bennett Rd CONTRACTOR Labor& COMMEFP 132MM Protection,Inc Industries Plan Reviews Date Review Type Description Assigned To Review Status 07/01/2020 Fire Sprinkler Building In Review 07/01/2020 Fire Sprinkler 1.Permit and set of approved plans to remain on site Mike Makela Approved with during installafi(II—) Conditions 2.significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections:may include hangers,earthquake bracing,sprinkler locations and pipe re-routing that could impact hydraulic calculations.Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 3.Hangers and earthquake bracing shall be installed in accordance with NFPA 13. 4.Relocated EC sprinkler shown on drawing appears to be greater than maximum allowed distance from north wall of classroom. 5.Hydrostatic test required:working pressure for 2 hours minimum 6.Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit. 7.Owner shall be provided with a set of approved plans and associated documents for their files. Fen Fee Description goiffiaiii,, Notes Amount Fire Sprinkler Permit Commercial NFPA 13/13R $75.00 Processing/Technology Fee $25.00 Fire System Plan Review Table 4-2 or 4-10 $100.00 Total $2N.80 bates - 1f)ate � Note Created By: 1.Permit and set of approved plans to remain on site during installation. 2.Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections:may include hangers,earthquake bracing,sprinkler locations and pipe re-routing that could impact hydraulic calculations.Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 07/13/2020 3.Hangers and earthquake bracing shall be installed in accordance with NFPA 13. Kristin Foster 4.Relocated EC sprinkler shown on drawing appears to be greater than maximum allowed distance from north wall of classroom. 5.Hydrostatic test required:working pressure for 2 hours minimum 6.Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit. 7.Owner shall be provided with a set of approved plans and associated documents for their files. U Date File Name 07/01/2020 6917282-3291 Planspdf 07/01/2020 6917283-3291 Agplication.pdf �� :� a f .. a a I City of • • ri % Fire Department E 1 �l G •� July 9, 2020 Permit Number: BLD 3291 Project Address: 505 E 3 d Street, Arlington Project Description: Fire Sprinkler Plans for Presidents Elementary School Contractor: Commercial Fire Protection, Inc. 17199 Bennett Road Mount Vernon, WA 98273 Re: Fire Suppression Shop Drawing Review Comments/Approval The Arlington Fire Department has completed a review of the Fire Suppression shop drawing submittal and approved the issuance of the permit with the following conditions: 1. Permit and set of approved plans to remain on site during installation. 2. Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections: may include hangers, earthquake bracing, sprinkler locations and pipe re- routing that could impact hydraulic calculations. Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 3. Hangers and earthquake bracing shall be installed in accordance with NFPA 13. 4. Relocated EC sprinkler shown on drawing appears to be greater than maximum allowed distance from north wall of classroom. 5. Hydrostatic test required: working pressure for 2 hours minimum 6. Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit. 7. Owner shall be provided with a set of approved plans and associated documents for their files. Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the system at project completion. Final approval will not be provided until all conditions are verified. Call at least 48 hours in advance to schedule inspections. If there are any questions please do not hesitate to call. Sincerely, W". C W&&a Mike Makela Assistant Fire Chief Arlington Fire Department OFFICE COP Y ��� �, 1 i ' �''. � ta� —�1 1. ' w zZ CM O z 2 0 1 c 1 ~ (T 8 _0 clJ 1 0 o U N N 1 CO) W > C1C oC 1 i-W al Et_J W w c$ 1 } N 1 as 0 0 c� crs WN �+ � A! � O r N Z S 1 eo a _ U oz—C Q �,' J 1 Q CL ci I �- i 3� LL 0 Wo a. r £ I5)2z = 1 m Zoo g U) 2 0 10Uz c I M m¢ 8 ~OTC z ~ ~ a' 100� M o: S�z off W � W IzWo >2 _ �( 1 .v ^�zi 8 _Z CL Z W O Z Q. K Jdm I �_ w O�wcl) U O r U J � J I Ua C��W - S mI Cn(n�Q W LJU W y` v ' =OEM -a O ZH-0� U aC Q U E� m°b g 1 OZccz Z W U j " �ci� a U) C'3��� W o U j m O ������������J Z Fn Q c7 J JWWK wW W O � W Irmo¢ o _Y Qa.inQ z doh Z a V CL U U W o k W Q c..) LLJ CC U - w 5 w J 1 Y ru 0LL O �VR °' /z� N Q LL. e Y z �� 2 ZIP N �w W w0 X W - -�_ J W a o — cr CL: W f —��— --- --- ---- - 0 � Q C !!rtrt z U L V o a O z w J Z w m V O W g O oF_ E. Z Z z rc Fr in¢ O Q } CL a � o Z ~ w oco o O < ~ ¢ � COEwa cc W Ow00 I- w o a Z U z m SW_ — Y W � a �aC� ¢ U ¢ � am Z � Z zQZ Y J2N � co .. .. .. .. O � C� =gip z > � U � QW f W /ram J Q UwJ d Z Q 00 LLiz00 LL C Z= m LL Z � a Z a m W O = z z f-1 Q a � � U Ir w Q N Z p z 3 j s a o Qc) < ArlingtonCity of Fir � - Department July 9, 2020 Permit Number: BLD 3291 Project Address: 505 E 3rd Street, Arlington Project Description: Fire Sprinkler Plans for Presidents Elementary School Contractor: Commercial Fire Protection, Inc. 17199 Bennett Road Mount Vernon, WA 98273 Re: Fire Suppression Shop Drawing Review Comments/Approval The Arlington Fire Department has completed a review of the Fire Suppression shop drawing submittal and approved the issuance of the permit with the following conditions: 1. Permit and set of approved plans to remain on site during installation. 2. Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections: may include hangers, earthquake bracing, sprinkler locations and pipe re- routing that could impact hydraulic calculations. Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 3. Hangers and earthquake bracing shall be installed in accordance with NFPA 13. 4. Relocated EC sprinkler shown on drawing appears to be greater than maximum allowed distance from north wall of classroom. 5. Hydrostatic test required: working pressure for 2 hours minimum 6. Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit. 7. Owner shall be provided with a set of approved plans and associated documents for their files. Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the system at project completion. Final approval will not be provided until all conditions are verified. Call at least 48 hours in advance to schedule inspections. If there are any questions please do not hesitate to call. Sincerely, UC Mike Makela Assistant Fire Chief Arlington Fire Department OFFICE C y �� FIRE SPRINKLER PERMIT APPLICATION ItNGV� Department of Community & Economic Development City of Arlington• 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF COMPLETE AND SCALED PLANS, TWO (2) SETS OF HYDRAULIC CALCULATIONS, TWO (2) SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE SPRINKLER PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION. Type of Permit: ❑ New Fire Sprinkler ❑✓ Fire Sprinkler Add/Alt ❑ Underground Fire Line Project Address: 505 E. 3rd St. Parcel ID#: Project Valuation: 2119.00 Number of Heads: 1 Building Area(Sq Ft):40 Owner. Arlington School District #16 Phone Number: 360 631-3116 Address: 135 S. French Ave City:Arlington State: WA Zip Code: 98223 Contact Person:Mark Webb Phone Number: 360 631-3116 Cell Phone: 360 631-3116 Email: mwebb@asd.wednet.edu Address: 17199 Bennett Rd City: Mount Vernon State: WA Zip Code:98273 Contractor: Commercial Fire Protection, Inc. Phone Number: 360 848-9093 EXT 113 Address. 17199 Bennett Rd. City: Mount Vernon State: WA Zip Code:98273 Contractor's License Number: COMMEFP132MM Expiration:08/16/20 ro.comfi Della Dellinger della@cre Contact Person: Email: P I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accordance with the laws,rules and regulation of the State of Washington. e,es=oeo,9eseeoe =ea4�esa�d 06/30/2020 Applicants Signature Date Della Dellinger Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received WEB Forms—131 Page 1 of 1 6116LP D co D N cn 70 ? � c O Z Z r u m �j0z g x z z 0 Z0 fTl Z oocZ -n Om -nO0 D m C ? O C m --I m � co Z C Fmo D r N = W D 0 �D To 0 w z o V O D W D r " Z > Z m 1 Z (n a ZJ M O C co M m 2 w < Q -0 r 0 mo � 7H O � O m � C)ao o m --I -1 -n Cl) z � ?' M o �� C7m � n -� m �mv ,z.� y � W S m Z m � m n m r z 0 c) ZO Dm m G) K Z Z z z m r-- m x m ` V x O m m m x _0 � m FA O x A U) c m } _ 0l z m a n o m N ca g ( o m Q I m (n_ 1 m �W m 1 i m°� �` 0 C: z o 4-0 ) j "'< 0 m m �L m m —1 m mmr x m 0 x zz° D Cn z �.������������ (A O W (n Z 0w�� (0)co n 1 Z D �7 z ?mzo m ,n ���z o Im ' 996 m� 1 % � m m r0 m commit = 3 1 uCD n), 070 1 n it A ° Nmm= m w 1 mil t mm � m o m w- mO ; Kim �Dzl 0 .... Zr -3 a. 1 °< 0mzl a m m �0 Z3� M' I 0w z001 DCn mom` "a 1 0 �m� -Z-� Z O z (n� Kim eaa I o �K�15 20 J7 (D T m �� � D� � 7mo� 1 ? z Z 0 o 0n rag°0 -�� 1 6\ �zml o r 00 - Kz a, I n l m m o (D r 3 es 10 0 -4 1 o C- m o Im 1 C o om LJ M , ,,n z N p Z N C �S NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL Cl CORRECTIONS REQUIRED Cl DO NOT OCCUPY aAPPROVED PERMIT#: 3 0 1 J AM PM DATE G JOB ADDRESS: 6 5 E .P. LOT#: PROJECT: p„ ,,,� .A F ,„ „ TYPE OF INSPECTION: OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 `I-,)5-doDo INSPECTOR DATE `fit Y O� • • [I PLANNING O CIVIL 0 BUILDING CITY OF ARLINGTON ' ti, • •1 CITY OF ARLINGTON a 18204 59th Avenue NE,Arlington, WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 505 E Third Street NE Permit#: 3291 Permit Expiration Date: 12/28/2020 Parcel#: 31050200401500 Valuation:2119.00 OWNER APPLICANT CONTRACTOR ARLINGTON SCHOOL DISTRICT 16 Commercial Fire Protection, Inc. Commercial Fire Protection,Inc 315 N FRENCH AVENUE 17199 Bennett Rd 17199 Bennett Rd ARLINGTON,WA 98223 Mount Vernon,WA 98273 Mount Vernon,WA 98273 360-848-9093 ext113 360-848-9093 LIC:COMMEFP132MM EXP:08/16/2020 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Sprinkler CODE YEAR: 2015 STORIES: I CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of,any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation, guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC I I O/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Digitally signed by Della Dellinger DDmail=d�Dell@ofireproer,o,' US Della Dellinger 7/16/2 Della Dellinger Date:2gzo.o7.1s1s:sa:2s-g7•oo• 7 lzv Signature Print Name Date Released By bat CONDITIONS 1. Permit and set of approved plans to remain on site during installation. 2. Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections: may include hangers, earthquake bracing, sprinkler locations and pipe re-routing that could impact hydraulic calculations.Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 3. Hangers and earthquake bracing shall be installed in accordance with NFPA 13.4. Relocated EC sprinkler shown on drawing appears to be greater than maximum allowed distance from north wall of classroom.5.Hydrostatic test required:working pressure for 2 hours minimum 6. Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit. 7. Owner shall be provided with a set of approved plans and associated documents for their files. 8.Adhere to approved plans. 9.Approved job copy shall be onsite for inspections. 10. Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 07/16/2020 Fire Sprinkler Permit $75.00 07/16/2020 Processing/Technology Fee $25.00 07/16/2020 Fire System Plan Review $100.00 07/16/2020 Credit Card Surcharge $6.00 Total Due: $206.00 Total Payment: $206.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Commercial COMMERCIAL FIRE PROTECTION, INC. Fire Protection 17199 BENNETT ROAD, MOUNT VERNON, WA 98273 trtc. (360) 848-9093 FAX (360) 848-1072 CONTRACTOR'S LICENSE NO. COMMEFP132MM WET SYSTEM - SYSTEM REVISION CONTRACTOR'S MATERIAL & TEST CERTIFICATE FOR ABOVEGROUND PIPING PROJECT NAME ARLINGTON SCHOOL DIST. PRESIDENTS ELEM. JOB NO. 2020522 PROJECT ADDRESS 505 E. THIRD ST. NE ARLINGTON, WA 98233 SYSTEM NO. 1 SERVES NEW TIMEOUT ROOM Upon completion of work,inspection and tests shall be made by the contractor's representatives and witnessed by an AHJ and/or owner's PROCEDURE representative. All defects shall be corrected and systems left in service before contractor's personnel finally leaves the job. A certificate shall be filled out and signed by both representatives- Copies shall be prepared for approving authorities,owners and contractor. It is understood that owner's representative's signature to no way prejudices any claim against contractor for faulty material,poor workmanship,or failure to comply with approving authority's requirements or local ordinances AUTHORITY HAVING CITY OF ARLINGTON JURISDICTION 6231 188T"ST.,ARLINGTON,WA 98223 PERMIT NO. 3291 PLANS Installation conforms to accepted plans ®YES ❑NO Equipment used is approved ®YES ❑NO If no,explain PIPE AND PIPE CONFORMS TO NFPA 13 - 2016 STANDARD ®YES ❑ NO FITTINGS FITTINGS CONFORM TO NFPA 13 - 2016 STANDARD ® YES ❑ NO Do you certify as the sprinkler contractor that welding procedures used comply with the minimum ❑ YES ❑NO requirements of AWS B2.1,ASME Section IX Welding and Brazing Qualifications,or other applicable qualification standard as required by the AHJ? WELDED PIPING Do you certify that all welding was performed by welders or welding operators qualfied in accordance the ❑ YES ❑NO rri minimum requirements of AWS B2.1,ASME Section IX Welding and Brazing Qualifications,or other ElYES ® NO r applicable qualification standard as required by the AHJ? ui Do you certify that welding was conducted in compliance with a documented quality control procedure to ❑YES ❑NO ensure that(1)all discs are retrieved;(2)that openings in piping are smooth,that slag and other welding residue are removed,(3) the internal diameters of piping are not penetrated;(4)completed welds are free from cracks,incomplete fusion,surface porosity greater than 1/16 inch in diameter,undercut deeper than 25%of the wall thickness or 1/32 inch;and(5)completed circumferential butt weld reinforcement does not exceed 3/32 inch? HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi for two hours or 50 psi above static pressure in excess of 150 psi for two hours All aboveground piping leakage shall be stopped HYDROSTATIC TEST ALL PIPING HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HOURS? [:1YES ❑ NO IF NO,STATE REASON WITNESSED BY FOR CITY OF.ARLINGTON _ SIGNATURE TITLE f � DATE Underground mains and lead-in connections to system risers flushed before connection made to sprinkler piping. FLUSHING VERIFIED BY COPY OF UNDERGROUND PIPING TEST CERTIFICATE? ❑ YES ® NO VERIFICATION FLUSHED BY INSTALLER OF UNDERGROUND SPRINKLER PIPING? ❑ YES ® NO OTHER—EXPLAIN EXISTING SYSTEM ADDITIVE AND DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS,SODIUM CORROSIVE SILICATE OR DERIVATIVES OF SODIUM SILICATE,BRINE,OR OTHER CORROSIVE CHEMICALS WERE NOT USED CHEMICAL FOR TESTING SYSTEM OR STOPPING LEAKS? ® YES ❑ NO VERIFICATION BLANK TEST GASKETS Number Used 0 Locations Number Removed 0 MANUFACTURER SIN TYPE MODEL YR.OF K- TEMP QUANTITY NUMBER MFG FACTOR RATING °F VIKING VK3021 RECD SSP QR 2020 5.6 200 1 SPRINKLERS TOTAL 1 ALARM DEVICE ALARM DEVICE MAX-TO OPERATE THRU TEST PIPE TYPE MAKE MODEL MIN SEC EXISTING EQUIPMENT EQUIPMENT OPERATES PROPERLY ® YES ❑ NO OPERATION IF NO, EXPLAIN HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION OF CONTROL VALVES AND ® YES ❑ NO CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? IF NO, EXPLAIN INSTRUCTIONS HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES? 1_ SYSTEM COMPONENTS INSTRUCTIONS YES ❑ NO 2 CARE AND MAINTENANCE INSTRUCTIONS _ ® YES ❑ NO 3- NFPA 25 ❑ YES NO HYDRAULIC DATA NAME PLATE PROVIDED ❑ YES ® NO NAMEPLATE IF NO, NO ADDITIONAL HYDRAULIC CALCULATIONS ARE PROVIDED FOR THE TENANT IMPROVEMENT THE EXPLAIN TENANT IMPROVEMENT IS LESS DEMANDING THAN THE HYDRUALICALLY MOST DEMANDING AREA ORGINALLY CALCULATED CUT OUT(DISC) DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL CUT OUTS(DISCS)ARE RETRIEVED? ❑ YES ❑ NO CERTIFICATION IF NO,EXPLAIN PRESSURE LOCATION MAKE& STATIC PRESSURE RESIDUAL PRESSURE FLOW RATE REDUCING &FLOOR MODEL SETTING INLET(PSI) OUTLET(PSI) INLET(PSI) OUTLET(PSI) (GPM) VALVEINSTALLED ❑YES ®NO PRESSURE REDUCING LOCATION& STATIC PRESSURE RESIDUAL PRESSURE FLOW RATE VALVE INSTALLED FLOOR MAKE&MODEL SETTING INLET(PSI) OUTLET(PSI) INLET(PSI) OUTLET(PSI) FLOW(GPM) ❑YES ® NO IF POWDER DRIVEN STUDS ARE USED IN CONCRETE,HAS REPRESENTATIVE SAMPLE TESTING BEEN POWDER DRIVEN SATISFACTORILY COMPLETED? ❑ YES ❑ NO STUD INSTALLED IF NO, ❑YES ® NO EXPLAIN IN-SERVICE DATE DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN MAIN DRAIN READING GAUGE LOCATED NEAR WATER SUPPLY TEST PIPE RESIDUAL PRESSURE WITH VALVES IN TEST PIPE TEST STATIC PRESSURE: PSI OPEN WIDE PSI FOR AHJ CITY OF ARLINGTON r Q FINAL ACCEPTANCE SIGNATURE TITLE ryyQ-V%44-frbLJ DATE ` .a S�� FOR PROPIATY O NER OR THEIR AUTHORIZED AGENT TEST WITNESSED SIGNATURE 1. TITLE 1T�> ! /I� lu DATE BY FOR C 0 MMERCIAL FIRE P )ECTION, INC. SIGNATURE TITLE FOREMAN DATE -�- I CERTIFY THAT THE INFORMATION HEREIN IS TRUE AND THAT THIS SPRINKLER SYSTEM WAS INSTALLED IN ACCORDANCE WITH RCW 18-160 AND THE RULES ADOPTED BY THE WASHINGTON ADMINISTRATIVE CODE AS ADMINISTERED �rrrr�rrrrrr�orrrrrrr�rrr�rrr� BYTHE STATE FIRE MARSHAL. WA31IN110MTONSTATE I CERTSFIOATE OF 009FLTS11OY Eric Si Fm FRaTac77OM'"""°"`men Sys CERTIFICATION g Eric Ray Sigmon 74734607-CEO Level PRINTED NAME OF CERTIFICATE OF COMPETENCY HOLDER 1 ; CERTIFICATE REGISTRATION NO. 7473-0607-CEG a COnwlwmhd Fire Protacdon,Ino. r COMMEF1213 M � ,tislao 16 SIGNATURE OF CERTIFICATLY OF COMPETENCY HOLDER a.r.rr.rr.".. ��r"r""r'r� DATE 20 20�Q Commercial Fire Protection, Inc. I ransmittai 17199 Bennett Road Mt.Vernon WA98273-9789 Today's Date: 11/17/2020 360 848-9093 COMMEFP 132 MM Date Sent: 11/17/2020 TO:Arlington Air Port, City Project: 2020522 18204 59th Ave NE Arlington School District Corrections Arlington WA 98223 3 Bldgs Addesses in Notes Arlington WA 98223 Prepared By: DELLA DELLINGER Item Quantity Description 1 1 Aboveground Test Certificate Notes Please sign and date this form as proof that you are in receipt of the above listed items. Return form to Commercial Fire Protection, Inc. Signed: Date: Printed Name: I I .1 CITY OF ARLINGTON a 18204 59th Avenue NE,Arlington, WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 505 E Third Street NE Permit#: 3291 Permit Expiration Date: 12/28/2020 Parcel#: 31050200401500 Valuation:2119.00 OWNER APPLICANT CONTRACTOR ARLINGTON SCHOOL DISTRICT 16 Commercial Fire Protection, Inc. Commercial Fire Protection,Inc 315 N FRENCH AVENUE 17199 Bennett Rd 17199 Bennett Rd ARLINGTON,WA 98223 Mount Vernon,WA 98273 Mount Vernon,WA 98273 360-848-9093 ext113 360-848-9093 LIC:COMMEFP132MM EXP:08/16/2020 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Sprinkler CODE YEAR: 2015 STORIES: I CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: I OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of,any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation, guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation, guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC I I O/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By bat CONDITIONS 1. Permit and set of approved plans to remain on site during installation. 2. Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections: may include hangers, earthquake bracing, sprinkler locations and pipe re-routing that could impact hydraulic calculations.Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 3. Hangers and earthquake bracing shall be installed in accordance with NFPA 13.4. Relocated EC sprinkler shown on drawing appears to be greater than maximum allowed distance from north wall of classroom.5.Hydrostatic test required:working pressure for 2 hours minimum 6. Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit. 7. Owner shall be provided with a set of approved plans and associated documents for their files. 8.Adhere to approved plans. 9.Approved job copy shall be onsite for inspections. 10. Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 07/16/2020 Fire Sprinkler Permit $75.00 07/16/2020 Processing/Technology Fee $25.00 07/16/2020 Fire System Plan Review $100.00 07/16/2020 Credit Card Surcharge $6.00 Total Due: $206.00 Total Payment: $206.00 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon INSPECTION REQUEST PROCEDURE To schedule an inspection: Call the Automated Inspection Line (360) 403-3417 Required Information: -Permit Number (Building, Right of Way or Civil) -Inspection Request (Type) -Inspection Time (am or pm) • A.M. inspections are scheduled from 8:00 am to 12:00 pm • P.M. inspections are scheduled from 1:00 am to 4:00 pm • You may request a specific time. We will do our best to honor the time requested. The Automated Inspection Line responds exactly like voicemail. Simply listen to the voice message and leave the information indicated above. You may stay on the line and request multiple inspections giving the required information each time. • Inspections must be called in before 3:3 0 PM to be on the next day inspection schedule Fire Suppression (fire alarm,fire sprin1der) inspection requests require at least 48 hours advanced notice a To cancel or modify an inspection please call (360) 403-3433. CITY OF ARLINGTON INSPECTION CARD No building construction shall be commenced until permit holder INSPECTION RECORD SHALL or his agent has posted this Inspection Record Card in a REMAIN AT JOB SITE conspicuous place on the premises. OWNER: ARLINGTON SCHOOL DISTRICT CONTRACTOR: COMMERCIAL FIRE PROTECTION INC JOB ADDRESS: 505 E THIRD STREET NE LOT NUMBER TYPE GROUP NATURE of WORK: FIRE SPRINKLER ALTERATION USE of BUILDING: SCHOOL PERMIT No: BLD-3291 DATE ISSUED:7/13/2020 INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB DEPARTMENT INSPECTION DATE(S) PASS FAIL INITIALS FOOTING BUILDING FOUNDATION (360)403-3417 UNDERFLOOR SHEARWALL PLUMBING(groundwork) ROUGH PLUMBING GAS PIPING ROUGH HEATING&VENTILATION FRAMING INSULATION WALLBOARD(SHEAR/RATED WALLS) CEILING GRID STRUCTURALSLAB CROSS CONNECTION CONTROL IN PREMISE (360)403-3417 GRADING TEMPORARY TECSP ASBUILTS APPROVED MAINTENANCE BOND STORM DRAINAGE SYSTEM PAVING,SIGNAGE&MARKINGS LANDSCAPING CONDITIONS ONSITE UTILITIES WATER ONSITE UTILITIES SEWER Sewer OFFSITE UTILITIES WATER (360)403-3608 OFFSITE UTILITIES SEWER SEWER PRETREATMENT Water CROSS CONNECTION CONTROL PREMISE (360)403-3526 SIDE SEWER/CLEANOUT/FINAL WATER SERVICE INSTALLATION WATER SERVICE FINAL (360)403-3417 HYDRO/FLUSH UNDERGROUND**INCL FDC FIRE ALARM /AUTOMATIC SPRINKLER HOOD SUPPRESSION SYSTEM FINAL FIRE WALK-THROUGH (360)403-3417 FINAL INSPECTION 4LL SIGNATURE BLOCKS MUST BE COMPLETE GAT Y U� City of • • July 9, 2020 Permit Number: BLD 3291 Project Address: 505 E Td Street, Arlington Project Description: Fire Sprinkler Plans for Presidents Elementary School Contractor: Commercial Fire Protection, Inc. 17199 Bennett Road Mount Vernon, WA 98273 Re: Fire Suppression Shop Drawing Review Comments/Approval The Arlington Fire Department has completed a review of the Fire Suppression shop drawing submittal and approved the issuance of the permit with the following conditions: 1. Permit and set of approved plans to remain on site during installation. 2. Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections: may include hangers, earthquake bracing, sprinkler locations and pipe re- routing that could impact hydraulic calculations. Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 3. Hangers and earthquake bracing shall be installed in accordance with NFPA 13. 4. Relocated EC sprinkler shown on drawing appears to be greater than maximum allowed distance from north wall of classroom. 5. Hydrostatic test required: working pressure for 2 hours minimum 6. Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit. 7. Owner shall be provided with a set of approved plans and associated documents for their files. Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the system at project completion. Final approval will not be provided until all conditions are verified. Call at least 48 hours in advance to schedule inspections. If there are any questions please do not hesitate to call. Sincerely, A We %W/C& Mike Makela Assistant Fire Chief Arlington Fire Department JOB COPY NEW TI I ROOM-- NEW PENDENT S RINKLER AN FLEXDROP �+ i I EXISTING EC PENDENT SPRINKLER TO BE RELOCATED o . ` NEW WALLS TO BOTTOM T OF ACT CEILING CP Ft RELOCATE 1" DROP WITH EXISTING EC PENDENT SPRINKLER EXISTING CLASSROOM 9'-6" N SPRINKLER PLAN 13� o 4 SCALE 1/4'=V-0" —METAL DECK 141 T.EILINGCON#610 TEK PLATE ER RING ------------�---------7 WASHINGTON STATE HANGER 1CPI CERTIFICATE OF COMPETENCY ; FIRE PROTECTION SPRINKLER SYSTEMS Mike Hinton 73 Commerc a Fire Protection,Inc. E>�ires COMMEFP132MM 12/31/20 ; SPRINKLER LEGEND w �0�29�Z0 i SVM I SIN# I MANUFACTURER I TYPE MODEL I VK3021 I VIKING RECD SSP OR I CHROME I CHROME 5.6 1/2' 200° 1 m ' !i9 nature Date � CONTRACT WITH COMMUCIAL FIBS FBITHTIOR, INC. ARLINGTON PUBLIC SCHOOLS 17199 BENNETT ROAD MT VERNON,WA 98273 315 NORTH FRENCH AVENUE LICENSE#COMMEFP132MM ARLINGTON,WA 98223 1 PHONE: (360)848-9093 FAX (360)848-1072 PROJECT MANAGER:MARK WEBB ARLINGTON SCHOOL DISTRICT CORRECTIONS PHONE:360-631-3116 PRESIDENTS ELEMENTARY SCHOOL FAX: 505 EAST 3RD STREET SUPERINTENDENT: ARLINGTON,WA 98223 PHONE: FAX: DESIGNER I DATE SHEET JOB NO. KEY PLAN MIKE HINTON 6/24/20 1 OF 1 2020522 Date: 03/30/2026 Permit#: 3291 Permit 07/01/2020 Date: Review 07/01/2020 Date: Permit FIRE SPRINKLER Type: Review FIRE SPRINKLER Type: Target Date: 07/15/2020 Scheduled 00:00 Time: Completed 07/09/2020 Date: Description: 1. Permit and set of approved plans to remain on site during installation. 2. Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections: may include hangers, earthquake bracing, sprinkler locations and pipe re-routing that could impact hydraulic calculations. Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 3. Hangers and earthquake bracing shall be installed in accordance with NFPA 13. 4. Relocated EC sprinkler shown on drawing appears to be greater than maximum allowed distance from north wall of classroom. 5. Hydrostatic test required: working pressure for 2 hours minimum 6. Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit. 7. Owner shall be provided with a set of approved plans and associated documents for their files. Review Status: Assigned Mike Makela To: Time In: 00:00 Time Out: 00:00 Hours: 1.0 Notes 07/13/2020 1. Permit and set of approved plans to remain on site during installation. 2. Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections: may include hangers, earthquake bracing, sprinkler locations and pipe re-routing that could impact hydraulic calculations. Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 3. Hangers and earthquake bracing shall be installed in accordance with NFPA 13. 4. Relocated EC sprinkler shown on drawing appears to be greater than maximum allowed distance from north wall of classroom. 5. Hydrostatic test required: working pressure for 2 hours minimum 6. Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit. 7. Owner shall be provided with a set of approved plans and associated documents for their files. Property Information Parcel#: 31050200401500 ARLINGTON SCHOOL DISTRICT 16 ARLINGTON SCHOOL DISTRICT 16 315 N FRENCH AVENUE 505 E 3RD STREET ARLINGTON, WA 98223 Zoning: Lot: Block: Permit#: 3291 Permit Date: 07/01/20 Permit Type: FIRE SPRINKLER Project Name: Arlington School District Applicant Name: Commercial Fire Protection, Inc. Applicant Address: 17199 Bennett Rd Applicant, City, State, Zip: Mount Vernon,WA 98273 Contact: Della Dellinger Phone: 360-848-9093 ext 113 Email: della@cflrepro.com Scope of Work: Sprinkler relocation Valuation: 2119.00 Square Feet: 40 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 07/17/2020 Permit Expires: 01/13/2021 Form Permit Type: Status: LASERFICHE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning ARLINGTON 31050200401500 505 E 3RD STREET SCHOOL DISTRICT 16 Contractors Contractor Primary Contact Phone Address Contractor Type License License# Commercial Fire Della L Dellinger 360-848-9093 17199 Bennett Rd CONSTRUCTION COA 601 011 373 Protection,Inc CONTRACTOR Commercial Fire Della L Dellinger 360-848-9093 17199 Bennett Rd CONSTRUCTION Labor&COMMEFP132MM Protection,Inc CONTRACTOR Industries Plan Reviews Date Review Type Description Assigned To Review Status 07/01/2020 FIRE SPRINKLER BUILDING 1.Permit and set of approved plans to remain on site during installation. 2.Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections:may include hangers,earthquake bracing,sprinkler locations and pipe re-routing that could impact hydraulic calculations.Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 07/01/2020 FIRE SPRINKLER 3.Hangers and earthquake bracing shall be installed in Mike Makela accordance with NFPA 13. 4.Relocated EC sprinkler shown on drawing appears to be greater than maximum allowed distance from north wall of classroom. 5.Hydrostatic test required:working pressure for 2 hours minimum 6.Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit. 7.Owner shall be provided with a set of approved plans and associated documents for their files. Fees Fee Description Notes Amount Fire Sprinkler System Commercial NFPA 13/13R $75.00 Processing/Technology $25.00 Fire System Plan Review Table 4-1 $100.00 Credit Card Service $6.00 Total $206.00 Attached Letters Date Letter Description 07/01/2020 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 07/14/2020 Della Dellinger 81301369 $200.00 07/14/2020 Della Dellinger 81301369 Launa Black $6.00 Outstanding Balance $0.00 Notes Date Note Created By: 07/23/2020 Emailed Della the approved plans,packet and permit to print for the job site. Kristin Foster 07/14/2020 Emailed the permit for signature. Kristin Foster 07/13/2020 1.Permit and set of approved plans to remain on site during installation. Kristin Foster 2.Significant deviations from approved plans made during installation shall be required to be resubmitted for review prior to inspections:may include hangers,earthquake bracing,sprinkler locations and pipe re-routing that could impact hydraulic calculations.Failure to submit revisions could result in cancellation of an inspection while a review of an as-built resubmittal is conducted. 3.Hangers and earthquake bracing shall be installed in accordance with NFPA 13. 4.Relocated EC sprinkler shown on drawing appears to be greater than maximum allowed distance from north wall of classroom. 5.Hydrostatic test required:working pressure for 2 hours minimum 6.Sprinkler system Contractor's Material and Test Certificate shall be submitted prior to close out of permit. 7.Owner shall be provided with a set of approved plans and associated documents for their files. Uploaded Files Date File Name 09/24/2021 9758427-3291 IC 9.25.2020.pdf 07/17/2020 7000120-3291 Issued Permit.pdf 07/01/2020 6917282-3291 Plans.pdf 07/01/2020 6917283-3291 Application.pdf