Loading...
HomeMy WebLinkAbout19716 49TH AVE NE_BLD3265_2026 NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY APPROVED PERMIT#: L AM'PM DATE: %I o JOB ADDRESS: �" I Lp r' Ca 'A"If QL- LOT#: PROJECT: TYPE OF INSPECTION: OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVEARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE Cl PLANNING 0 CIVIL BUILDING CITY OF ARLINGTON c CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: - - -360 403 3417-Permit Center:360 403-3551 BUILDING PERMIT 19716 49th Avenue NE Permit#:3265 Permit Expiration Date: 12/23/2020 Parcel#: 00671900002200 Valuation: .00 OWNER APPLICANT CONTRACTOR CLONINGF.R JOE S&JANICE Fast Water Heater Fast Water Heater Company t9716 49TH AVE NE 11715 N Creek Parkway S,#C106 11715 North Creek Parkway South,Ste C- 106 ARLINGTON,WA 98223-7767 Bothell,WA 98011 Bothell,WA 98011 425-636-7054 (425)636-7084 Ext. LIC:FASTWWH948BC EXP:01/04/2022 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Fast Water Heater Company 11715 North Creek Parkway South,Ste C-106 Bothell,WA 98011 (425)636-7084 LTC#: EXP: LIC#:FASTWWH948BC EXP: 01/04/2022 JOB DESCRIPTION PERMIT TYPE: Residential Plumbing CODE YEAR: STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRCI 10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City or Arlington must be reported on your sales tax return form and coded City of Arlington#3101. `t "'n G 71�' Zip IAI-nStm -FoJte- 6-26-2020 Signature Print Name Dale Released By Date CONDITIONS Adhere to installation of the approved appliance as submitted.Call for final inspection(inspection line 360403-3417). THIS PERMIT AUTHORIZES ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 06/26/2020 Inspection Fee $75.00 06/26/2020 ProcessinglTechnology Fee $25.00 06/26/2020 Plumbing Base $25.00 06/26/2020 Water Healer $25.00 Total Due: $150.00 Total Payment: $0.00 Balance Due: $150.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 4$hours for Fire Inspections Wben calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon r I ` Permit#: 3265 Permit Date: 06/26/20 Project Name: Cloninger Site Address: 19716 49th Avenue NE Company/Applicant Name: Fast Water Heater Company/Applicant Address: 11715 N Creek Parkway S, #C 106 City, State, Zip: Bothell, WA 98011 Contact: Hannah Manning Phone: 425-636-7054 Email: hmanning@fastwaterheater.com Permit Type: Residential Plumbing Valuation: 0.00 Square Feet: 1571 Number of Stories: 1 Type of Construction: VB Occupancy Type: R-3; Residential Scope of Work: Replace electric HWT MIC/Opportunity Zone: Permit Issued: Permit Expires: 12/23/2020 DNU: Status: fN PROCESS Property Parcel# Address Legal Description Owner Name Owner Phone Zoning CLONINGER JOE S I I I Single Family 00671900002200 19716 49TH AVE NE Residence- &JANICE Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# Fast Water Heater (425)636-7084 11715 North PLUMBING Labor& Creek Parkway FASTWWH948BC Company Ext. South,Ste C-106 CONTRACTOR Industries Fees Fee Description Notes Amount Inspection Fee $75.00 _ _ �. I Processing/Technology Fee $25.00 Plumbing Base Permit Fee $25.00 Water Heater Tank or Tankless $25.00 Total $150.00 Notes Date !Mote Created By: 06/26/2020 Model#XE 50M09N EF.93 Kristin Foster Uploaded Files Date File Name 06/26/2020 6892000-3265 Cut Sheet.pdf 06/26/2020 6892001-3265 npplication.pdf J I Some online services are current Y unavailable. See a list of service outage-s—k qRs �ini,va gov/agencyLsystem-statu ) L&I regional offices are closed to public visits until further notice. Offices can still help you by phone from 8 a.m.to 5 p.m.weekdays (except state holidays). Use the phone number for your closest regional office (httos://Inl,wa.gov agency/contact/#office•locations),or you can call the Office of Information and Assistance at 360-902-5800. wa:ni-gm.s�die oepanmmi of Labor&Industries(https://Ini.wa.gov). FAST WATER HEATER COMPANY Owner or tradesperson 11715 N CREEK PARKWAYS,C-106 Principals BOTHELL,WA 98011 JORDAN,JEFFERY DAVID,PARTNER/MEMBER 425-814-8381 KING County ■ HANLEYBROWN, JASON,PARTNER/MEMBER Doing business as FAST WATER HEATER COMPANY WA UBI No. Business type 602 564 544 Limited Liability Company Parent company Governing persons FWH ACQUISITION COMPANY LLC JEFFREY DAVID JORDAN JASON HANLEYBROWN; (License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no FASTWWH948BC Effective—expiration 01103/2006—01/04/2022 Bond DEVELOPERS SURETY&INDEM CO $12,000.00 Bond account no 549792C Received by L&I Effective date 01/03/2006 01/01/2005 Expiration date Until Canceled Insurance Middlesex Insurance Company $1,000,000.00 Policy no. A0145403003 Received by L&I Effective date 02/24/2020 02/17/2020 Expiration date 02/17/2021 Middlesex Insurance Company $1,000,000.00 �l Policy no A0145403002 Received by L&I Effective date 02/14/2020 02/17/2020 Expiration date 02/17/2021 Insurance history Savings ............a... .... No svings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. j.&l Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations Infraction no. EZINS01165 Satisfied Issue date RCW/WAC 01/29/2020 19.28.041 RCW Violation city Violation amount BOTHELL $1,000.00 Type of violation ELECTRICAL CITATION Description Offering to perform,submitting a bid for, advertising,installing or maintaining cables, conductors or equipment that convey or utilize electrical current without having a valid electrical contractor license. Infraction no. PCZIK02125 Satisfied Issue date RCW/WAC 06/16/2017 18.106.020 Violation city Violation amount BOTHELL $1,000.00 Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman,specialty or trainee certificate, temporary permit or medical gas endorsement as required. Infraction no. PFAZF00278 Satisfied Issue date RCW/WAC 04/12/2016 18.106.020 Violation city Violation amount BOTHELL $1,000.00 Type of violation PLUMBER INFRACTION Description Contractor failed to provide proper supervision as required. Infraction no. FCHMA01002 Satisfied Issue date RCW/WAC 04/01/2016 43.22.435 RCW Violation city Violation amount BOTHELL $400.00 Type of violation r SFAS INFRACTION Description Failure to correct alteration violations to a mobile home or manufactured home as required. Infraction no. FCHMA00995 Satisfied Issue date RCW/WAC 02/29/2016 43.22.435 RCW Violation city Violation amount BOTHELL $200.00 Type of violation FAS INFRACTION Description Failure to correct alteration violations to a mobile home or manufactured home as required. Infraction no. PSACE00226 Satisfied Issue date RCW/WAC 01/05/2015 18.106.020 Violation city Violation amount BOTHELL $1,000.00 Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman,specialty or trainee certificate, temporary permit or medical gas endorsement as required.(Employed Christopher William Best to engage in the trade of plumbing while in possession of an expired trainee certificate at above SFR) Infraction no. PSACE00227 Satisfied Issue date RCW/WAC 01/05/2015 18.106.020 Violation city Violation amount BOTHELL $1,000.00 Type of violation PLUMBER INFRACTION Description Contractor failed to provide proper supervision as required.(Employed plumber trainee Friedrich Laurence Timmons to engage in the trade of plumbing at above SFR without providing him with supervision required by statute) Infraction no. PESPR00717 Satisfied Issue date RCW/WAC 09/26/2014 18.106.020 Violation city Violation amount BOTHELL $1,000.00 Type of violation PLUMBER INFRACTION Description Contractor failed to provide proper supervision as required.Contractor failed to provide proper supervision as required.Chris L Lowrie /plumber trainee installed a hot water tank without supervision. ,: y . Certifications & Endorsement, OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent No active Washington registered apprentices exist for this business.Washington allows the use of apprentices registered with Oregon or Montana.Contact the Oregon Bureau of Labor&Industries or Montana Department of Labor &Industry to verify if this business has apprentices. Workers' Comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 053,806-01 Doing business as FAST WATER HEATER COMPANY Estimated workers reported Quarter 1 of Year 2020 76 to 100 Workers" L&I account contact T2/CRYSTAL RALKEY(360)902-4635-Email:KECR235@lni.wa.gov Public Works Requirements Verify the contractor is eligible to perform work on public works projects. Required Training—Effective July 1,2019 Needs to complete trainirig. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace Safety& Health Check for any past safety and health violations found on jobsites this business was responsible for. No inspections during the previous 6 year period. Yet. ! � y ����� Y RESIDENTIAL PLUMBING PERMIT APPLICATION IN �� Department of Community & Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW PLUMBING INSTALLATION FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:19716 49th Ave NE Project Description:Remove/replace electric water heater Owner:Janice Cloninger 19716 49th Ave N E Address: City:Arlington State:WA Zip Code: 98223 Phone: 425-422-4285 Email: hmanning@fastwaterheater.com Applicant:Fast Water Heater Address:11715 North Creek Pkwy S #C106 City:Bothell State:WA Zip Code: 98011 Phone: 425-636-7054 Email: hmanning@fastwaterheater.com CONTRACTOR INFORMATION Contractor Name:Fast Water Heater Address: 11715 North Creek Pkwy 5 #C106 City:Bothell StateYVA Zip Code:98011 License Number:FASTWWH 948BC Expiration:l/4/2022 Phone:425-636-7054 Email:hmanning@fastwaterheater.com STAFF USE ON Y Permit#: fj'l/"P ll� Accepted by: Date REV 2015 Page 1 of 2 j`KY °'' RESIDENTIAL PLUMBING PERMIT APPLICATION IINVk; Department of Community & Economic Development City of Arlington• 18204 59th Ave NE •Arlington,WA 98223• Phone(360) 403-3551 Plumbing Section (check all that apply) (Check all that apply and indicate the number of fixtures proposed) ❑ Bath/Shower Combo (4.0) x Q Sink (1.5) x ❑ Shower (2.0) x ❑ Lavatory (1.0) x ❑ Clothes Washer (4.0) x It Water Closet (2.5) x ❑ Dishwasher (1.5) x Water Heater x 1 ❑ Hose Bibb (2.5) x Water Heater Model# n� Other (list) x XE50M09N Proposed Water Piping Size:N/A_ Proposed Piping Material: N/A Proposed DWV Material:N/A Proposed DWV Size: N/A • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASS 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) • Cross-Connection-Control may be required �air.�tale l�ast�tut� Applicant Signature Date: 06/25/2020 hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. REV 2015 Page 2 of 2 TM PER ORMANCE PLUS 11 The new degree of comfort:" PERFORMANCE PLUS T" High Efficiency electric water heaters are engineered for longer life _ and feature an electronic LED system Efficiency Features ■.93 UEF ■High performance and lower ■Isolated tank design reduces operating cost conductive heat loss ■Compliant with many electric utility ■Dual 5500 or dual 4500 watt copper incentive programs heating elements ■Electric junction box located above Performance heating elements for easy installation ■FHR: 52-63 gallons, based on ■Over-temperature protector cuts gallon capacity off power in excess temperature ■Recovery: 21 -25 GPH at a situations 90'F rise"' Plus... Electronic LED ■Temperature and pressure relief valve System included ■Simple and easy to 0 ■Low lead compliant read Warranty ■Indicates heating ■9-Year limited warranty for tank element and thermostat operation and parts, 2-year full in-home labor Longer Life warranty' ■Premium grade anode rod provides See written warranty for complete details long-lasting tank protection Units meet or exceed ANSI requirements and have been tested according to D.O.E.procedures.Units Self Cleaning meet or exceed the energy efficiency requirements of NAECA,ASHRAE standard 90,ICC Code and all ■Fights sediment . state energy efficiency performance criteria. build-up ■Saves energy PERFORMANCE PLUS High Efficiency 40 and 50-Gallon Capacities 240 Volt AC/Single Phase T U� '�r.,.,� 9 Received LEEO ftht=1 JUN .L 6 2020 See specifications chart on back. 04/17 FORM NO.THO-P+E9 N Rev.3 0 The new degree of comfort:" PERFORMANCE Martanal RatW RocWary FIt$IHart Tank I HalphttD Ship atom 9aman fiamoe Model In D.P.R. Ra16q Height 11i Cane. Diameter Weight EneW IbM Factor Fuel typo Description Capacity CaRadry her 90•F Rea B.RN. A B C lift) Factor FM Tad 50 45 XE50T09EL551.11 25 1 63 58-7/8 61-5/8 20-1/4 121 0.95 0.93 Tam 50 45 XE50T09EL451.11 21 63 5-7/8 61-5/8 20-1/4 121 0.95 0.93 Medium 50 45 XE50M09EL55UI 25 62 48 50-1/2 23 132 0.95 0.93 Medium 50 45 XE50M09EL451.11 21 62 48 50-1/2 23 132 0.95 0.93 Medium 40 3fi XF40MO9Fl55111 25 53 48-1/4 h0-1/7 20-114 10fi 0.95 0.93 Medium 40 36 XE40M09EL45U1 21 53 48-114 50-1/2 20-1/4 106 0.95 0.93 Tall 40 36 XE40T09EL45U1 21 52 fi0.314 63-5/8 19-1/4 109 0.95 0.93 Uniform Energy Factor and Energy Factor based on Department of Energy(D.O.E.)requirements. „ •Heaters furnished with standard 240 volt AC,single phase non-simultaneous wiring,and 5500 watt upper and lower healing elements. a "Recovery=wattage/2.42 x temp.rise Example: 550OW =25 GPH 2.42 x 90° HOT WATER 0 COLD —Recovery calculations used are based on 5500 watt elements used in non-simultaneous operation. CONNECTION WATER RELIEF VALVE CONNECTION CONNECTION � ANODE ViON l DIAMCETER LEED P•Inl=1 A 0 B WATER CONNECTIONS ALL 3/4"N.P.T. In keeping with its policy of continuous progress and product improvement Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery,Alabama 36117-4305 • www.rheem.com 04/17 FORM ND_THD-P+E9 N Rev.3 XE50MO9N RESIDENTIAL PLUMBING PERMIT APPLICATION �fN Department of Community & Economic Development City of Arlington• 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW PLUMBING INSTALLATION FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 19716 49th Ave NE Project Description:Remove/replace electric water heater Owner: Janice Cloninger 19716 49th Ave N E Address: City:Arlington State:WA Zip Code: 98223 Phone: 425-422-4285 Email. hmanning@fastwaterheater.com Applicant: Fast Water Heater Address: 11715 North Creek Pkwy S #C106 City:Bothell State WA Zip Code: 98011 Phone: 425-636-7054 Email: hmanning@fastwaterheater.com CONTRACTOR INFORMATION Contractor Name: Fast Water Heater Address: 11715 North Creek Pkwy S #C106 City:Bothell StateWA Zip Code- 98011 License Number.. Expiration.1/4/2022 Phone-425-636-7054 Email.hmanning@fastwaterheater.com STAFF USE ONLY Permit #: Accepted by: Date REV 2015 Page 1 of 2 RESIDENTIAL PLUMBING PERMIT APPLICATION �fN Department of Community & Economic Development City of Arlington• 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 Plumbing Section (check all that apply) (Check all that apply and indicate the number of fixtures proposed) ❑ Bath/Shower Combo (4.0) x ❑ Sink (1.5) x ❑ Shower (2.0) x ❑ Lavatory (1 .0) x ❑ Clothes Washer (4.0) x ❑ Water Closet (2.5) x ❑ Dishwasher (1 .5) x Water Heater x 1 ❑ Hose Bibb (2.5) x Water Heater Model # ❑ Other (list) x XE501V109N Proposed Water Piping Size: N/A Proposed Piping Material: N/A Proposed DWV Material: N/A Proposed DWV Size: N/A • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) • Cross-Connection-Control may be required Ll" 5� 1 Applicant Signature: °°�°°°3°°a°a°=3 ° ° Date: 06/25/2020 1 hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. REV 2015 Page 2 of 2 PERFORMANCE PLUS TMI I 11 The new degree of comfort- PERFORMANCE PLUS TM High Efficiency electric water heaters are engineered for longer life and feature an electronic LED system op{c LEOS, Efficiency Features �` y" ■ .93 LIEF ■High performance and lower ■Isolated tank design reduces operating cost conductive heat loss ■Compliant with many electric utility ■Dual 5500 or dual 4500 watt copper incentive programs heating elements ■Electric junction box located above Performance heating elements for easy installation FHR: 52 -63 gallons, based on ■Over-temperature protector cuts gallon capacity off power in excess temperature situations ■Recovery: 21 - 25 GPH at a 90' F rise** Plus... Electronic LED ■Temperature and pressure relief valve System included Simple and easy to 0 ■Low lead compliant read Warranty Indicates heating ■9-Year limited warranty for tank element and thermostat operation and parts, 2-year full in-home labor Longer Life warranty* Premium grade anode rod provides See written warranty for complete details long-lasting tank protection Units meet or exceed ANSI requirements and have been tested according to D.O.E.procedures.Units Self Cleaning meet or exceed the energy efficiency requirements of NAECA,ASHRAE standard 90,ICC Code and all Fights sediment state energy efficiency performance criteria. build-up .. — — — Saves energy PERFORMANCE PLUS High Efficiency 40 and 50-Gallon Capacities 240 Volt AC/Single Phase O D� V� t LEED Point=1 See specifications chart on back. 04/17 FORM NO.THD-P+E9 N Rev.3 a The new degree of comfort:" II■ • II■ PLUS'" High Efficiency Specifications Nominal Rated Recovery First Hour Tank Height to Ship Uniform Gallon Gallon Model in G.P.H. Rating Heigh Water Conn. Diameter Weight Energy Energy Fa Fuel Type Description Capacity Capacity Number 90*F Rise G.P.H. A B C (LBS.) Factor (UEF) Tall 50 45 XE50T09EL551J1 25 63 58-7/8 61-5/8 20-1/4 121 0.95 0.93 Tall 50 45 XE50T09EL451J1 21 63 58-7/8 61-5/8 20-1/4 121 0.95 0.93 Medium 50 45 XE50M09EL55U1 25 62 48 50-1/2 23 1 132 0.95 0.93 Medium 50 45 XE50M09EL451J1 21 62 48 50-1/2 23 132 0.95 0.93 Medium 40 36 XE40M09EL55U1 25 53 48-1/4 50-1/2 20-1/4 106 0.95 0.93 Medium 40 36 XE40M09EL45U1 21 53 48-1/4 50-1/2 20-1/4 106 0.95 0.93 Tall 40 36 XE40T09EL45U1 21 52 60-3/4 63-5/8 19-1/4 109 0.95 0.93 Uniform Energy Factor and Energy Factor based on Department of Energy(D.O.E.)requirements. •Heaters furnished with standard 240 volt AC,single phase non-simultaneous wiring,and 5500 watt upper and lower heating elements. B„ Recovery=wattage/2.42 x temp.rise'F. Example: 550OW =25 GPH 2.42 x 90' HOT WATER C) COLD **Recovery calculations used are based on 5500 watt elements used in non-simultaneous operation. CONNECTION-(; WATER RELIEF VALVE CONNECTION CONNECTION ANODE ROD is �C DIAMETER LEED Point=7 A 0 B WATER CONNECTIONS ALL 3/4"N.P.T. In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery,Alabama 36117-4305 • www.rheem.com 04/17 FORM NO.THD-P+E9 N Rev.3 NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY XAPPROVED PERMIT#: 'AM PM DATE: JOB ADDRESS: � � <<D "� ) � � LOT#: r' PROJECT: 1 TYPE OF INSPECTION: OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION J THEACTIONS OR CORRECTIONS INDICATED ABOVEARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INS/�P/�ECTION CALL: 360-403-3417 INSPECTOR DATE Cl PLANNING 0 CIVIL BUILDING CITY OF ARLINGTON CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT Permit#:3265 19716 49th Avenue NE Permit Expiration Date: 12/23/2020 Parcel#: 00671900002200 Valuation: .00 OWNER APPLICANT CONTRACTOR CLONINGER JOE S&JANICE Fast Water Heater Fast Water Heater Company 19716 49TH AVE NE 11715 N Creek Parkway S,#C106 11715 North Creek Parkway South, Ste C- 106 ARLINGTON,WA 98223-7767 Bothell,WA 98011 Bothell,WA 98011 425-636-7054 (425)636-7084 Ext. LIC:FASTWWH948BC EXP:01/04/2022 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Fast Water Heater Company 11715 North Creek Parkway South,Ste C-106 Bothell,WA 98011 (425)636-7084 LTC#: EXP: LTC#:FASTWWH948BC EXP: 01/04/2022 JOB DESCRIPTION PERMIT TYPE: Residential Plumbing CODE YEAR: STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. lD � �lil/1 G kvlki! TvkeV 6-26-2020 Signature Print Name Date Released By Date CONDITIONS Adhere to installation of the approved appliance as submitted.Call for final inspection(inspection line 360-403-3417). THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.TI[IS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 06/26/2020 Inspection Fee $75.00 06/26/2020 Processingrrachnology Fee $25.00 06/26/2020 Plumbing Base $25.00 06/26/2020 Water Heater $25.00 Total Due: $150.00 Total Payment: $0.00 Balance Due: $150.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON Dw 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 —BUILDING PERMIT 19716 49th Avenue NE Permit#:3265 Permit Expiration Date: 12/23/2020 Parcel#: 00671900002200 Valuation: .00 OWNE APPLICANT 7 CONTRACTOR CLONINGER JOE S&JANICE Fast Water Heater Fast Water Heater Company 19716 49TH AVE NE 11715 N Creek Parkway S,#C106 11715 North Creek Parkway South, Ste C- 106 ARLINGTON,WA 98223-7767 Bothell,WA 98011 Bothell,WA 98011 425-636-7054 (425)636-7084 Ext. LIC:FASTWWH948BC EXP:01/04/2022 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Fast Water Heater Company 11715 North Creek Parkway South, Ste C-106 Bothell,WA 98011 (425)636-7084 LIC#: EXP: LIC#:FASTWWH948BC EXP: 01/04/2022 JOB DESCRIPTION PERMIT TYPE: Residential Plumbing CODE YEAR: STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: - `PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. fCk(, it T-os Gel 6-26-2020 Signature Print Name Date Released By Date CONDITIONS ' Adhere to installation of the approved appliance as submitted. Call for final inspection(inspection line 360-403-3417). THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. ' PERMIT FEES - Date Description Fee Amount 06/26/2020 Inspection Fee $75.00 06/26/2020 Processing/Technology Fee $25.00 06/26/2020 Plumbing Base $25.00 06/26/2020 Water Heater $25.00 Total Due: $150.00 Total Payment: $0.00 Balance Due: $150.00 - CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 3265 Permit Date: 06/26/20 Permit Type: RESIDENTIAL PLUMBING Project Name: Cloninger Applicant Name: Fast Water Heater Applicant Address: 11715 N Creek Parkway S, #C 106 Applicant, City, State, Zip: Bothell,WA 98011 Contact: Hannah Manning Phone: 425-636-7054 Email: hmanning@fastwaterheater.com Scope of Work: Replace electric HWT Valuation: 0.00 Square Feet: 1571 Number of Stories: 1 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 07/28/2020 Permit Expires: 01/24/2020 Form Permit Type: Status: LASERFICHE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00671900002200 19716 49TH AVE NE CLONINGER JOE S 111 Single Family &JANICE Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# FAST WATER 11715 N CREEK PLUMBING HEATER 425.636.7054 PKWY S,Ste CONTRACTOR COA 602 564 544 C106 FAST WATER 11715 N CREEK PLUMBING LABOR& HEATER 425.636.7054 PKWY S,Ste CONTRACTOR INDUSTRIES FASTWWH948BC C106 Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 08/11/2020 R00.WATER 08/11/2020 08/11/2020 BUILDING Approved HEATER FINAL Fees Fee Description Notes Amount Inspection $75.00 Processing/Technology $25.00 Plumbing Base Permit Fee $25.00 Water Heater(Tank) $25.00 Credit Card Service $4.50 Total $154.50 Attached Letters Date Letter Description 06/26/2020 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 07/27/2020 Amy Tillman 81482071 $150.00 07/27/2020 Amy Tillman CC Surcharge Transaction $4.50 81482071 Outstanding Balance $0.00 Notes Date Note Created By: 07/27/2020 Emailed the permit for signature. Kristin Foster 06/26/2020 Model#XE 50M09N EF.93 Kristin Foster Uploaded Files Date File Name 09/30/2021 9798294-3265 IC 8.11.2020.pdf 07/28/2020 7051813-3265 Issued Permit.pdf 06/26/2020 6892000-3265 Cut Sheet.pdf 06/26/2020 6892001-3265 Application.pdf