Loading...
HomeMy WebLinkAbout16902 52ND AVE NE_BLD3252_2026 = CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 16902 52nd Ave NE Permit#:3252 Perm it Expiration Date: 12/21/2020 Parcel#: 00571800001200 Valuation: .00 OWNER APPLICANT CONTRACTOR COOPER JASON CM Heating CM Heating Inc 16902 52ND AVE NE 1415 Broadway 1415 Broadway ARLINGTON,WA 98223 Everett,WA 98201 Everett,WA 98201 425-259-0550 425-259-0550 LTC:CMHEAMU977DN EXP:03/15/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR CM Heating Inc 1415 Broadway Everett,WA 98201 425-259-0550 LIC#:CMHEAMH877DN EXP: 03/15/2021 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC I I0/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington 43101. Wf,01t,)4-,2 KAILANA MONIZ 06/24/20 ,eP a. 6/24/2020 Signature UPrint Name Date ReleasaBy Date CONDITIONS 3"concrete pad with seismic bracing attached.Provide electrical disconnect.Lines shall be insulated;use of adhesive tapes are prohibited.Adhere to approved appliance.Approved job copy shall be onsite for inspections.gall for final inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount ubl14110L0 Inspection Fee $75.00 06/24/2020 Heat Pump/Heat Exchangers $25.00 06/24/2020 Mechanical Base $25.00 06/24/2020 Processing/Technology Fee $25.00 Total Due: $150.00 Total Payment: $0.00 Balance Due: $150.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:16902 52ND AVE NE ARLINGTON WA 98223 Project Description:MECHANICAL - COOPER Owner: CATHRINA COOPER Address: 16902 52ND AVE NE City: ARLINGTON State.WA Zip Code: 98223 Phone: 2068198222 Errlail:MOMMYCATHRINA@GMAIL.COM Applicant: CM HEATING INC Address: 1415 BROADWAY City: EVERETT StateYVA Zip Code: 98201 Phone: 4252590550 Email: RENEE@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:CM HEATING INC Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration: 5/3/2021 Phone:4252590550 Email:RE N E E@ C M H EAn N G.0 OM STAFF USE ONC1\ Received' Permit#: '� � Accepted by: Date: JUN 2 3 2020 6/16LP Page 1 of 2 Ax. RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) Model # AFUE Heat Pump Model # AFUE HSPE [}� AC Unit Model ## MXZ3C30NA2 SEER 10.6 I]i Freestanding Stove 11) Fire Place Insert ❑ Outdoor BBQ i-ji Gas Piping 1:11 Solid-Fuel Appliance Other Gas Piping Information Not Applicable: ID Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances �YIcS�'�l��nfl7li�C'�l Applicant Signature: ....,,.....,-..,� Date: 06/23/2020 Applicant Printed Name: RENEE VISITACION I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 SUBMITTAL DATA: MXZ-3C30NA9 MULT14NDOOR INVERTER HEAT-PUMP SYSTEM At ELECMC Job Name: System Reference: Date: 1 ' Outdoor Unit:MXZ-3C24NA ACCESSORIES ❑ 3/8"x 1/2"Port Adapter(MAC-A454JP-E) CI 1/2"x 3/8"Port Adapter(MAC-A455JP-E) a 1/2"x 5/8"Port Adapter(MAC-A456JP-E) D 1/4"x 3/8"Port Adapter(PAC-493PI) 13 3/8"x 5/8"Port Adapter(PAC-SG76RJ-E) o M-NET Adapter(PAC-IF01MNT-E) o Base Heater(PAC-645BH-E) (For data on specific indoor units,see the MXZ-C Technical and Service Manual.) Specifications Model Name Unit Type MXZ-3C30NA2 Rated Capacity Btu/h 28,400/27,400 Cooling` Capacity Range Btu/h 12,600-28,400/12,600-27,400 (Non-ducted/Ducted) Rated Total Input W 2,680/2,860 Rated Capacity Btu/h 28,600/27,600 Heating at 47°F" Capacity Range Btu/h 11,400-36,000/11,400-35,000 (Non-ducted/Ducted) Rated Total Input W 2,150/2,220 Heating at 17°F' Rated Capacity Btu/h 16,000/15,100 (Non-ducted/Ducted) Rated Total Input W 2,120/2,140 Power Supply Voltage,Phase,Hertz 208/230V,1-Phase,60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 25 MCA A 22.1 Voltage Indoor-Outdoor S1-S2 V AC 208/230 Indoor-Outdoor S2-S3 V DC±24 Compressor INVERTER-driven Scroll Hermetic Fan Motor(ECM) F.L.A. 2.43 Cooling 1 Sound Pressure Level Heating dB(A) 52 56 External Dimensions(H x W x D) In(mm) 31-11/32 x 37-13/32 x 13 796 x 950 x 330 Net Weight Lbs(kg) 137(62) External Finish Munsell 3.OY 7.8/1.1 Refrigerant Pipe Size O.D.— Liquid(High Pressure) In(mm) 1/4(12.7) Eight Ports Gas(Low Pressure) A: 1/2(6.35);B,C:3/8(9.52) Max.Refrigerant Line Length Ft(m) 230(70) Max.Piping Length for Each Indoor Unit Ft(m) 82(25) Max.Refrigerant Pipe Height I If IDU is Above ODU 49(15) Difference If IDU is Below ODU Ft(m) 49(15) Connection Method Flared/Flared -Refrigerant R41OA "Rating Conditions per AHRI Standard: Cooling I Indoor:80°F(27"C)DB/67"F(19°C)WB Heating at 470F I Indoor:70O F(210 C)DB/60°F(16"C)WB Heating at 17"F I Indoor:70"F(21°C)DB Cooling I Outdoor:950 F(350 C)DB/23.9°C(75°F)WB Heating at 47"F i Outdoor:470 F(80 C)DB/430 F(60 C)WB Heating at 170 F I Outdoor:170 F(-8°C)DB/150 F(-9°C)WB Received Specifications are subject to change without notice. B<Ipt *12 ftbishi Electric US,Inc. _1 j3W12 • • 1 OPERATING RANGE: ENERGY EFFICIENCIES: Outdoor Indoor Unit Type SEER EER HSPF COP @ COP 47°F @ 17°F Cooling 14 to 115°F(-10 to 46°C)DB Non-ducted Heating 5 to 65°F(-15 to 18°C)WB (06+06+09) 19.0 10.6 10.6 3.90 2.77 Ducted and 17.6 10.1 10.1 3.77 2.78 Non-ducted Ducted 16.2 9 6 9.6 3.64 2.78 (09+09+09) NOTES: • Minimum of two Indoor Units must be connected to the MXZ-3C30NA2. • Minimum installed capacity cannot be less than 12,000 Btu/h. • Total connected capacity must not exceed 130%of outdoor unit capacity. • System can operate with only one Indoor Unit turned on. • Information provided at 208/230V. • For Reference: -MXZ-C Technical&Service Manual for detailed specifications and additional information per Indoor Unit Combination. -MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. MVZ CONNECTION RULES: • Only 1 MVZ may be used on any system. • When an MVZ is connected,total connected capacity must be 100%or less. • When an MVZ is connected,no P-Series indoor units can be used(PCA,PLA,or PEAD). Notes: Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. ' + OPERATIONAL i , PERFORMANCE DUCTED: Operational Cooling .• IndoorPerformance for .- Current(208/23OV) Unit Combinations Unit A Unit B Unit C (W) 9 9000 0 0 10900 0 0 12 12000 0 0 13600 0 0 15 15000 0 0 18000 0 0 18 17200 0 0 21600 0 0 24 24000 0 0 26000 0 0 9+9 9000 9000 0 10900 10900 0 9+12 9000 12000 0 10500 14000 0 9+15 9000 15000 0 10200 17000 0 9+18 8733 17467 0 9133 18267 0 9+24 7418 19782 0 7473 19927 0 12+12 12000 12000 0 13600 13600 0 12+15 11644 14556 0 12178 15222 0 TBD 12+18 10880 16320 0 10960 16440 0 12+24 9067 18133 0 9133 18267 0 15+15 13600 13600 0 13700 13700 0 15+18 12364 14836 0 12455 14945 0 18+18 13600 13600 0 13700 13700 0 9+9+9 9000 9000 9000 9133 9133 9133 9+9+12 8220 8220 10960 8280 8280 11040 9+9+15 7582 7582 12636 7582 7582 12636 9+9+18 7050 7050 14100 7000 7000 14000 9+12+12 7582 10109 10109 7582 10109 10109 9+12+15 7050 9400 11750 7000 9333 11667 12+12+12 9400 1 9400 9400 9333 9333 9333 Specifications are subject to change without notice, ©2016 Mitsubishi Electric US,Inc. 14W NW OPERATIONAL PERFORMANCE, contd. NON-DUCTED: IndoorUperational Cooling Capacity Range(Btu/h) Performance for Range Unit Combinations (Unit A I Unit • 6 6000 0 0 7400 0 0 9 9000 0 0 11000 0 0 12 12000 0 0 14400 0 0 15 14000 0 0 18000 0 0 18 17200 0 0 21600 0 0 24 22500 0 0 27600 0 0 6+6 6000 6000 0 7400 7400 0 6+9 6000 9000 0 7360 11040 0 6+12 6000 12000 0 7333 14667 0 6+15 5714 14286 0 7257 18143 0 6+18 5750 17250 0 6900 20700 0 6+24 5440 21760 0 5520 22080 0 9+9 9000 9000 0 11000 11000 0 9+12 8571 11429 0 10886 14514 0 9+15 8625 14375 0 10350 17250 0 TBD 9+18 8600 17200 0 9200 18400 0 9+24 7418 19782 0 7527 20073 0 12+12 11500 11500 0 13800 13800 0 12+15 11467 14333 0 12267 15333 0 12+18 10880 16320 0 11040 16560 0 12+24 9067 18133 0 9200 18400 0 15+15 13600 13600 0 13800 13800 0 15+18 12364 14836 0 '12545 15055 0 18+18 13600 13600 0 13800 13800 0 6+6+6 6000 6000 6000 7400 7400 7400 6+6+9 6000 6000 9000 7371 7371 11057 6+6+12 6000 6000 12000 7100 7100 14200 6+6+15 5778 5778 14444 6311 6311 15778 6+6+18 5680 5680 17040 5720 5720 17160 6+6+24 5000 5000 20000 5000 1 5000 20000 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US.Inc. MXZ-3C30NA2 OPERATIONAL PERFORMANCE, contd. NON•DUCTED: Operational Cooling Capacity Range(Btu/h) IndoorPerformance for .- Range Current(208/23OV) Unit Combinations (W) (Unit A+Unit B+Unit C) Unit A Unit B Unit C 6+9+9 6000 9000 9000 7100 10650 10650 6+9+12 5778 8667 11556 6311 9467 12622 6+9+15 5680 8520 14200 5720 8580 14300 6+9+18 5382 8073 16145 5382 8073 16145 6+12+12 5680 11360 11360 5720 11440 11440 6+12+15 5382 10764 13455 5382 10764 13455 6+12+18 5000 10000 15000 5000 10000 15000 6+15+15 5000 12500 12500 TBD 5000 12500 12500 9+9+9 8667 8667 8667 9467 9467 9467 9+9+12 8520 8520 11360 8580 8580 11440 9+9+15 8073 8073 13455 8073 8073 13455 9+9+18 7500 7500 15000 7500 7500 15000 9+12+12 8073 10764 10764 8073 10764 10764 9+12+15 7500 10000 12500 7500 10000 12500 12+12+12 10000 10000 10000 10000 10000 10000 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. DIMENSIONS: IRW I Unit: inch(mm) -7i• z3-5!a• 7fa• Bea,A r WWI, 2-1.11 SNOW 1,161040 MOIL 13/33• (Foundation Boll M10) 3.3f3 � P P Sitle All In-,, m T a-♦t-Sfta'Oran/4t0/ "I air � bo�sennr9e !3r 24W rzt-13f32'1 Oven torte '-Wr 2-07/8'knockout hole IFoundallon Ball M10) 1-112' (EomLKIVvk ) i-sfe• 7-ter ]v32• �3• rof32• 3-07/a'punched hole t[aI 000V were hotel Mi Kl £' n reuvry O� _�.wa n 7 Aei tllake O� m WS Unil C LIa 1/L'f0fi 351YlAiE b � Q� lb GAS 318109.521FLA4f N ? GAS Unit B W 'Uml A— LIU i/L'140.fSA'I ARE S GA51/2'I0V.1 WARE vF a 1.FREE SPACE b B � 3-fiI16'a mam 3 w i ]-,jifb„_w mac u.25f3Y a mae /Co+bull plates i 2.SERVICE SPACE conduit connector h h � 9 _ c Lock nut 3•bfb'a Dore xmnce 9Auf 13.25137'a ilgre 1]-25132'a more MITSUBISHI /I. ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com E1� �s FORM#MXZ-3C30NA2 for Multiple Indoor Unit Styles-201605 Intertek Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. L&I regional offices are closed to public visits until further notice. Offices can still help you by phone from 8 a.m.to 5 p.m. weekdays (except state holidays). Use the phone number for your closest regional office (https//Im wa gov agency/contact/7office-locations)., or you can call the Office of Information and Assistance at 360-902-5800. wasnn,gwo s�uie oepa— Labor&Industriesmiar_(http,6;[(jn wa.gpyl C M HEATING INC Owner or tradesperson 1415 BROADWAY ................................................................... Principals EVERETT,WA 98201 Garner,James N,PRESIDENT 425-259-6666 SNOHOMISH County ■ Umayam,John A,VICE PRESIDENT ■ Umayam,Antonio(Tony)G,SECRETARY ■ Umayam,Antonio(Tony)G,TREASURER ■ Garner,James N,AGENT Garner,Paul,PRESIDENT (End:06/29/2016) Garner,Kathleen D,SECRETARY (End:06/29/2016) ■ Garner,Kathleen D,TREASURER (End:06/29/2016) Doing business as C M HEATING INC WA UBI No Business type 601 114 652 Corporation Governing persons JAMES GARNER PAUL M GARNER; KATHLEEN GARNER; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Electrical Contractor Active Meets current requirements. License specialties GENERAL License no CMHEAMH877DN Effective—expiration 03/15/2013—03/15/2021 Designated administrator. Active Giacomi,John Meets current requirements. License type License no. Electrical Administrator GIACOJ*840MG Bond Contractors Bonding&Insurance Co $4,000.00 Bond account no SC6810 Received by L&I Effective date 03/15/2013 02/28/2000 Expiration date Until Canceled a vings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent No active Washington registered apprentices exist for this business.Washington allows the use of apprentices registered with Oregon or Montana.Contact the Oregon Bureau of Labor&Industries or Montana Department of Labor &Industry to verify if this business has apprentices. Workers' Comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 490,794-01 Doing business as CHIMNEY MASTERS Estimated workers reported Quarter 1 of Year 2020"51 to 75 Workers" L&I account contact T3/NICHOLE CAROW(360)902-5634-Email:CANI235@lni.wa.gov Public Works Requirements Verify the contractor is eligible to perform work on public works projects. Required Training—Effective July 1,2019 Needs to complete training. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace Safety& Health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/16/2015 No violations Inspection no 317935327 Location 1415 Broadway Everett,WA 98201 �_y Q. RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 16902 52ND AVE NE ARLINGTON WA 98223 Project Description:MECHANICAL - COOPER Owner: CATHRINA COOPER Address: 16902 52ND AVE NE City: ARLINGTON State.WA Zip Code: 98223 Phone: 2068198222 Email:MOMMYCATHRINA@GMAIL.COM Applicant: CM HEALING INC Address. 1415 BROADWAY City. EVERETT StateYVA Zip Code: 98201 Phone. 4252590550 Email. RENEE@CMHEALING.COM CONTRACTOR INFORMATION Contractor Name:CM HEALING INC Address: 1415 BROADWAY City: EVERETf State WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration: 5/3/2021 Phone: 4252590550 Email:RENEE@CMHEALING.COM STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) Model # AFUE Heat Pump Model # AFUE HSPE ❑ AC Unit Model # MXZ3C30NA2 SEER 10.6 ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: tl5a51c3bba4a9294ftlaeB�b41e Date: 06/23/2020 Applicant Printed Name: RENEE VISITACION I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 CITY OF ARLINGTON Dw 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 - -BUILDING PERMIT 16902 52nd Ave NE Permit#:3252 Permit Expiration Date: 12/21/2020 Parcel#: 00571800001200 Valuation: .00 [)WNER APPLICANT a CONTRACTOR COOPER JASON CM Heating CM Heating Inc 16902 52ND AVE NE 1415 Broadway 1415 Broadway ARLINGTON,WA 98223 Everett,WA 98201 Everett,WA 98201 425-259-0550 425-259-0550 LIC:CMHEAMH877DN EXP:03/15/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR - CM Heating Inc 1415 Broadway Everett,WA 98201 425-259-0550 LIC#: CMHEAMH877DN EXP: 03/15/2021 LIC#: EXP: JOB DESCRIPTION IL T or- PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: RERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 42or� "--a- 6/24/2020 Signature Print Name Date Rcicas By Date . CONDITIONS 3"concrete pad with seismic bracing attached.Provide electrical disconnect.Lines shall be insulated;use of adhesive tapes are prohibited.Adhere to approved appliance.Approved job copy shall be onsite for inspections. Call for final inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. ERMIT FEES Date Description Fee Amount 06/24/2020 Inspection Fee $75.00 06/24/2020 Heat Pump/Heat Exchangers $25.00 06/24/2020 Mechanical Base $25.00 06/24/2020 Processing/Technology Fee $25.00 Total Due: $150.00 Total Payment: $0.00 Balance Due: $150.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon SUBMITTAL DATA: 1 1 ' MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM A&ELECTRIC Job Name: System Reference: Date: 1 ��Ilii�IIIIIIIIIIIIIIVuuI��, 1' dIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIiI 1 j �Illlllllllllllllllllllllllllllllllllllllllllh 11 illllllllllllllllllllllllllllllllllllllllllllp' Outdoor Unit:MXZ-3C24NA ACCESSORIES ❑ 3/8"x 1/2"Port Adapter(MAC-A454JP-E) ❑ 1/2"x 3/8"Port Adapter(MAC-A455JP-E) ❑ 1/2"x 5/8"Port Adapter(MAC-A456JP-E) ❑ 1/4"x 3/8"Port Adapter(PAC-493PI) ❑ 3/8"x 5/8"Port Adapter(PAC-SG76RJ-E) ❑ M-N ET Adapter(PAC-I FO 1 M NT-E) ❑ Base Heater(PAC-645BH-E) (For data on specific indoor units,see the MXZ-C Technical and Service Manual.) Specifications Model Name Unit Type MXZ-3C30NA2 Rated Capacity Btu/h 28,400/27,400 Cooling* Capacity Range Btu/h 12,600-28,400/12,600-27,400 (Non-ducted/Ducted) Rated Total Input W 2,680/2,860 Rated Capacity Btu/h 28,600/27,600 Heating at 47°F* Capacity Range Btu/h 11,400-36,000/11,400-35,000 (Non-ducted/Ducted) Rated Total Input W 2,150/2,220 Heating at 17°F* Rated Capacity Btu/h 16,000/15,100 (Non-ducted/Ducted) Rated Total Input W 2,120/2,140 Power Supply Voltage,Phase, Hertz 208/230V, 1-Phase,60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 25 MCA A 22.1 Voltage Indoor-Outdoor S1-S2 V AC 208/230 Indoor-Outdoor S2-S3 V DC±24 Compressor INVERTER-driven Scroll Hermetic Fan Motor(ECM) F.L.A. 2.43 Sound Pressure Level Cooling dB(A) 52 Heating 56 External Dimensions(H x W x D) In(mm) 31-11/32 x 37-13/32 x 13 (796 x 950 x 330) Net Weight Lbs(kg) 137(62) External Finish Munsell 3.OY 7.8/1.1 Refrigerant Pipe Size O.D.— Liquid(High Pressure) In(mm) 1/4(12.7) Eight Ports [Gas(Low Pressure) A: 1/2(6.35); B,C:3/8(9.52) Max.Refrigerant Line Length Ft(m) 230(70) Max.Piping Length for Each Indoor Unit Ft(m) 82(25) Max.Refrigerant Pipe Height If IDU is Above ODU 49(15) Difference If IDU is Below ODU Ft(m) 49(15) Connection Method Flared/Flared Refrigerant R41 OA Rating Conditions per AHRI Standard: Cooling I Indoor:80'F(27o C)DB/67o F(190 C)WB Heating at 47oF I Indoor:70o F(210 C)DB/60'F(16o C)WB Heating at 170 F I Indoor:70o F(210 C)DB Cooling I Outdoor:950 F(350 C)DB/23.9°C(75'F)WB Heating at 470F I Outdoor:470 F(80 C)DB/430 F(60 C)WB Heating at 170 F I Outdoor:170 F(-80 C)DB/150 F(-90 C)WB Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. SPECIFICATIONS: 1 • • OPERATING RANGE: ENERGY EFFICIENCIES: Outdoor Indoor Unit Type SEER EER HSPF COP @ COP 47°F @ 17°F Cooling 14 to 115°F(-10 to 46'C)DB Non-ducted Heating 5 to 65-F(-15 to 18°C)WB (06+06+09) 19.0 10.6 10.6 3.90 2.77 Ducted and 17.6 10.1 10.1 3.77 2.78 Non-ducted Ducted (09+09+09) 16.2 9.6 9.6 3.64 2.78 NOTES: • Minimum of two Indoor Units must be connected to the MXZ-3C30NA2. • Minimum installed capacity cannot be less than 12,000 Btu/h. • Total connected capacity must not exceed 130%of outdoor unit capacity. • System can operate with only one Indoor Unit turned on. • Information provided at 208/230V. • For Reference: MXZ-C Technical&Service Manual for detailed specifications and additional information per Indoor Unit Combination. MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. MVZ CONNECTION RULES: • Only 1 MVZ may be used on any system. • When an MVZ is connected,total connected capacity must be 100%or less. • When an MVZ is connected,no P-Series indoor units can be used(PCA,PLA,or PEAD). Notes: Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. OPERATIONAL PERFO1'.' DUCTED: Operational Cooling IndoorPerformance for Power Unit Combinations Unit A Unit B Unit C (W) 9 9000 0 0 10900 0 0 12 12000 0 0 13600 0 0 15 15000 0 0 18000 0 0 18 17200 0 0 21600 0 0 24 24000 0 0 26000 0 0 9+9 9000 9000 0 10900 10900 0 9+ 12 9000 12000 0 10500 14000 0 9+15 9000 15000 0 10200 17000 0 9+18 8733 17467 0 9133 18267 0 9+24 7418 19782 0 7473 19927 0 12+ 12 12000 12000 0 13600 13600 0 12+ 15 11644 14556 0 12178 15222 0 TBD 12+ 18 10880 16320 0 10960 16440 0 12+24 9067 18133 0 9133 18267 0 15+ 15 13600 13600 0 13700 13700 0 15+ 18 12364 14836 0 12455 14945 0 18+ 18 13600 13600 0 13700 13700 0 9+9+9 9000 9000 9000 9133 9133 9133 9+9+ 12 8220 8220 10960 8280 8280 11040 9+9+ 15 7582 7582 12636 7582 7582 12636 9+9+ 18 7050 7050 14100 7000 7000 14000 9+12+12 7582 10109 10109 7582 10109 10109 9+12+15 7050 9400 11750 7000 9333 11667 12+ 12+ 12 9400 9400 9400 9333 9333 9333 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. ' OPERATIONAL • PERFORW NON-DUCTED: Operational Cooling IndoorPerformance for Power Usage Range Current(208/23OV) Unit Combinations Unit A Unit B Unit C (W) 6 6000 0 0 7400 0 0 9 9000 0 0 11000 0 0 12 12000 0 0 14400 0 0 15 14000 0 0 18000 0 0 18 17200 0 0 21600 0 0 24 22500 0 0 27600 0 0 6+6 6000 6000 0 7400 7400 0 6+9 6000 9000 0 7360 11040 0 6+12 6000 12000 0 7333 14667 0 6+15 5714 14286 0 7257 18143 0 6+18 5750 17250 0 6900 20700 0 6+24 5440 21760 0 5520 22080 0 9+9 9000 9000 0 11000 11000 0 9+12 8571 11429 0 10886 14514 0 9+ 15 8625 14375 0 10350 17250 0 TBD 9+ 18 8600 17200 0 9200 18400 0 9+24 7418 19782 0 7527 20073 0 12+ 12 11500 11500 0 13800 13800 0 12+ 15 11467 14333 0 12267 15333 0 12+ 18 10880 16320 0 11040 16560 0 12+24 9067 18133 0 9200 18400 0 15+ 15 13600 13600 0 13800 13800 0 15+ 18 12364 14836 0 12545 15055 0 18+ 18 13600 13600 0 13800 13800 0 6+6+6 6000 6000 6000 7400 7400 7400 6+6+9 6000 6000 9000 7371 7371 11057 6+6+ 12 6000 6000 12000 7100 7100 14200 6+6+ 15 5778 5778 14444 6311 6311 15778 6+6+ 18 5680 5680 17040 5720 5720 17160 6+6+24 5000 5000 20000 5000 5000 20000 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. OPERATIONAL O. , NON-DUCTED: Operational Cooling IndoorPerformance for Power is O Unit Combinations Unit A Unit B Unit C (W) 6+9+9 6000 9000 9000 7100 10650 10650 6+9+ 12 5778 8667 11556 6311 9467 12622 6+9+ 15 5680 8520 14200 5720 8580 14300 6+9+ 18 5382 8073 16145 5382 8073 16145 6+ 12+ 12 5680 11360 11360 5720 11440 11440 6+ 12+ 15 5382 10764 13455 5382 10764 13455 6+ 12+ 18 5000 10000 15000 5000 10000 15000 5000 12500 12500 6+15+15 TBD 5000 12500 12500 9+9+9 8667 8667 8667 9467 9467 9467 9+9+ 12 8520 8520 11360 8580 8580 11440 9+9+ 15 8073 8073 13455 8073 8073 13455 9+9+ 18 7500 7500 15000 7500 7500 15000 9+ 12+ 12 8073 10764 10764 8073 10764 10764 9+12+15 7500 10000 12500 7500 10000 12500 12+ 12+ 12 10000 10000 10000 10000 10000 10000 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. DIMENSIONS: Unit: inch (mm) 6-7/8' 23-5/8' 6-7/8' nR-Air V fake 2-13/16' 9-1/16' 4-19/32" 2-1/32" 3-1/16' 2-U Shaped Notched Hole 13/32" (Foundation Bolt 11101 Sid.Air Intake b m 6-m1-5/16"Drain Hole N 13/32" b o s�hnrge 2-(15/32"x1-13/32"l Oval Hole 1-1/32" 2-07/8'knockout hole (Foundation Bolt H10) 1-1/2' 1 ...cfin wire hole) 1-5/8' 37-13/32' 31/32' 13" 19/32" rl'l.nnl. 78punched holecting wire hole) Hnnd(e \ Handle Ol P V Hantlle Hontlle 0 2-3/4" O® Air Intake �®=Cal GAS}Unif C Llp 1/L'(06.351FLARE O® GAS}Unif g GAS 1/1109.52IFLARE O® Lla 1 LIG 1/L'(012.7)FLARE ,fU�IrBP11 GAS}Unil A— GAS 1/2'(012.]IFLARE v1-11131 14-7/32' 1.FREE SPACE E E E 3-15/16" or more LIQ 777T7 3-15/16' or more7r,325,32' or more Conduit plates 2.SERVICE SPACE E2. v L L Conduit connector _ yy� Lock nut 3-15116" or more FF SERVICE SPACE 13-25132" or more 13-25/32" or more MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ETA us FORM#MXZ-3C30NA2 for Multiple Indoor Unit Styles-201605 Intertek Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. CITY OF ARLINGTON ` 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 16902 52nd Ave NE Permit#:3252 Permit Expiration Date: 12/21/2020 Parcel#: 00571800001200 Valuation: .00 APPLICANT CONTRACTOR COOPER JASON CM Heating CM Heating Inc 16902 52ND AVE NE 1415 Broadway 1415 Broadway ARLINGTON,WA 98223 Everett,WA 98201 Everett,WA 98201 425-259-0550 425-259-0550 LIC:CMHEAM 1877DN EXP:03/15/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR CM Heating Inc 1415 Broadway Everett,WA 98201 425-259-0550 LIC#: CMHEAMH877DN EXP: 03/15/2021 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL V The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington 93101. KAILANA MONIZ 06/24/20 6/24/2020 Signature Print Name Date Releas By Date _ CONDITIONS 3"concrete pad with seismic bracing attached.Provide electrical disconnect.Lines shall be insulated;use of adhesive tapes are prohibited.Adhere to approved appliance.Approved job copy shall be onsite for inspections. Call for final inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. im PERMIT FEES IL Date Description Fee Amount 06/24/2020 Inspection Fee $75.00 06/24/2020 Heat Pump/Heat Exchangers $25.00 06/24/2020 Mechanical Base $25.00 06/24/2020 Processing/Technology Fee $25.00 Total Due: $150.00 Total Payment: $0.00 Balance Due: $150.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 3252 Permit Date: 06/24/20 Permit Type: RESIDENTIAL MECHANICAL Project Name: Cooper Applicant Name: CM Heating Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett,WA 98201 Contact: Renee Visitacion Phone: 425-259-0550 Email: renee@cmheating.com Scope of Work: Install HP Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 06/24/2020 Permit Expires: 12/21/2020 Form Permit Type: Status: LASERFICHE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00571800001200 16902 52ND AVE NE COOPER JASON 111 Single Family Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Plumbing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751 W ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION UBI 605890285 ST STE 200 CONTRACTOR Fees Fee Description Notes Amount Inspection $75.00 Heat Pump/Heat Exchangers $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Credit Card Service $4.50 Total $154.50 Attached Letters Date Letter Description 06/24/2020 Building Permit 06/24/2020 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 06/24/2020 james garner 80996816 $150.00 06/24/2020 80996816 Raelynn Jones $4.50 Outstanding Balance $0.00 Uploaded Files Date File Name 06/24/2020 6880114-3252 Application.pdf 06/24/2020 6880115-3252 Specs.pdf