Loading...
HomeMy WebLinkAbout18935 59th Avenue NE_BLD3226_2026 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 18935 59th Avenue NE Permit#:3226 Permit Expiration Date 12/09/2020 Parcel#: 31051500401200 Valuation: 7900.00 OWNER APPLICANT CONTRACTOR City of Arlington Pye Barker Fire Pye Barker Fire 18204 59th Drive NE PO Box 265 PO Box 265 Arlington,WA 98223 Burlington,WA 98233 Burlington,WA 98233 360-755-5444 360-755-5444 LIC: PYEBAFS807DO EXP:03/20/2022 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Sprinkler CODE YEAR: 2015 STORIES: I CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this pen-nit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error-or on the basis of incorrect, inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRC110. SALES TALC NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. C ZD S gnature Print Natfic D•to Released By Da e CONDITIONS 1. Pen-nit and set of approved plans to remain on site during installation. 2. System shall be connected to fire alarm system per IFC 904.3.5. 3. A dual action manual pull station that activates the building fire alarm system shall be installed on the exterior of tke spray booth.4.A horn strobe,, )be installed on the exterior of the spray bood- 1 shall operate upon activation of the spray booth fire suppression system. 5.Operation of the spray booth fire suppression system shall shut-off the exhaust fan. 6.A nozzle cap blow-off test or similar test shall be conducted and witnessed by the Arlington Fire Department. 7.Installation certification form to be completed and submitted prior to close out of permit. 8.Approved job copy shall be onsite for installation and inspection. 9.Adhere to approved plans 10. Call for inspections Items noted above are conditions of the permit and shall be verified as a part of the final inspection of the system at project completion.Final approval will not be provided until all conditions are verified. Call at least 48 hours in advance to schedule an inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. w PERMIT FEES Date Description Fee Amount 06/29/2020 Fire Sprinkler Permit $375.00 06/29/2020 Processing/Technology Fee $25.00 06/29/2020 Fire System Plan Review $147.31 Total Due: $547.31 Total Payment: $0.00 Balance Due: $547.31 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon �I i - � r f Permit#: 3226 J4, I Permit Date: 06/12/20 Project Name: Top Secret Coatings Site Address: 18935 59th Avenue NE Company/Applicant Name: Pye Barker Fire Company/Applicant Address: PO Box 265 City, State, Zip: Burlington, WA 98233 Contact: Nisha Taylor Phone: 360-755-5444 Email: taylorn@pyebarkerfire.com Permit Type: Fire Sprinkler Valuation: 7900.00 Square Feet: 0 Number of Stories: 0 Type of Construction: Occupancy Type: Scope of Work: Fire suppression for paint booth MIC/Opportunity Zone: Permit Issued: Permit Expires: 12/09/2020 DNU: Status: 1N PROCESS Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31051500401200 18935 59th Avenue NE City of Arlington Contractors Contractor Primary Contact Phone Address Contractor Type License License# Pye Barker Fire Nisha Taylor 360-755-5444 PO Box 265 CONTRACTOR Labor and PYEBAFS807DO Industries Plan Reviews Date Review Type Description Assigned'To Review Status 06/12/2020 Fire Sprinkler Building in Review 06/12/2020 Fire Sprinkler Mike Makela In Review 06/12/2020 Fire Sprinkler PW-Wat-Rev In Review �' I I Uploaded Files Date File Name 06/12/2020 6813477-3226 ppli ati n pdf 06/12/2020 6813476-3226 Plans and Speciticatiows.pdf T 471�02'$, FIRE SPRINKLER PERMIT APPLICATION Department of Community &Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF COMPLETE AND SCALED PLANS, TWO (2) SETS OF HYDRAULIC CALCULATIONS, TWO (2) SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE SPRINKLER PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION. Type of Permit: ✓❑ New Fire Sprinkler ❑ Fire Sprinkler Add/Alt ❑ Underground Fire Line 18935 59TH AVE NE ARLINGTON WA Project Address: Parcel ID#: Project Valuation: 7900 Number of Heads: 5 Building Area(Sq Ft):0000 Owner: TOP SECRETCOAl1NGS Phone Number: 360-651-2540 Address: 18935 59TH AVE NE City:ARLINGTON State: WA Zip Code: 98223 Contact Person:NISHA TAYLOR Phone Number: 360-755-5444 Cell Phone: 360-610-9682 Email: taylorn@pyebarkerfire.com Address: PO BOX 265 City:BURLINGTON State: WA Zip Code:98233 Contractor: PYE BARKER FIRE Phone Number: 360-755-5444 Address: PO BOX 265 City:BURLINGTON State: WA Zip Code:98233 Contractor's License Number: PYEBAFS807D0 Expiration:03/2022 Contact Person: Email: ar NISHA TAYLOR taylorn@pyebkerf ire.corn I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accordance with the laws,rules and regulation of the State of Washington. 1 ��������1'f� 06/10/2020 Applicants Signature Date NISHA TAYLOR Print Applicants Name FOR STAFF USE OIL Recelved Y (Ly.i� JUN,11 2020 Permit-# Accept By Amount Received Receipt# Date Received WEB Forms—131 Page 1 of 1 6/16LP _ 1 _ _ _ L&I regional offices are closed to public visits until further notice. Offices can still help you by phone from 8 a.m.to 5 p.m. weekdays (except state holidays). Use the phone number for your closest regional office (ntt g:,n";.wa.gOV/ag_,„ „t.,<,,,,u„rri,- or you can call the Office of Information and Assistance at 360-902-5800. O1YasNngfon$Idl1 Mp.rl�a�-I Labor&Industries(htt s:!/Ini.wa.go). PYE-BARKER FIRE AND SAFETY LLC Owner or tradesperson PROCTOR,BARTON 11605 HAYNES BRIDGE RD ALBERT ALPHARETTA,GA 30009 Principals 678-805.0155 PROCTOR,BARTON ALBERT,PARTNER/MEMBER ■ TRAYLOR,JAMES HOWARD,AGENT ■ BRINKMAN,JASON LEE,AGENT WA UBI No Business type 604 541 987 Limited Liability Company License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active Meets current requirements. License specialties FIRE PROTECT SYSTEM License no. PYEBAFS807DO Effective—expiration 03/20/2020—03/20/2022 Bond Platte River Ins Co $6,000.00 Bond account no 41426581 Received by L&I Effective date 03120/2020 03/09/2020 Expiration date Until Canceled Insurance i Everest Indemnity Ins Co $1,000,000.00 Policy no 51g1003490201 } Received by L&I Effective date 03/20/2020 01/01/2020 Expiration date 01/01/2021 I Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Certifications & Endorsement:. OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent o active Washington registered apprentices exist for this business.Washington allows the use of apprentices registered with Oregon or Montana.Contact the Oregon Bureau of Labor&Industries or Montana Department of Labor &Industry to verify If this business has apprentices. Workers' Comp No active workers'comp accounts during the previous 6 year period. Public Works Requirements Verify the contractor is eligible to perform work on public works projects. Required Training—Effective July 1,2019 Completed the training on 4/28/2020 Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace Safety & Health Check for any past safety and health violations found on jobsites this business was responsible for, No inspections during the previous 6 year period. .. .-� r � ti .. � � ArlingtonCit of r • • �::.l 7Fire Department �L1NG June 16, 2020 Permit Number: BLD 3226 Project Address: 6525 188th Street NE, Arlington Project Description: Spray Booth Suppression System Plans for Top Secret Customs and Restoration Contractor: Alpine Fire & Safety Systems P.O. Box 265 Burlington, WA 98233 Re: Spray Booth Suppression System Shop Drawing Review Comments/Approval The Arlington Fire Department has completed a review of the Fire Suppression shop drawing submittal and approves the issuance of the permit with the following conditions: Permit Conditions: 1. Permit and set of approved plans to remain on site during installation. 2. System shall be connected to fire alarm system per IFC 904.3.5. 3. A dual action manual pull station that activates the building fire alarm system shall be installed on the exterior of the spray booth. 4. A horn strobe shall be installed on the exterior of the spray booth and shall operate upon activation of the spray booth fire suppression system. 5. Operation of the spray booth fire suppression system shall shut-off the exhaust fan. 6. A nozzle cap blow-off test or similar test shall be conducted and witnessed by the Arlington Fire Department. 7. Installation certification form to be completed and submitted prior to close out of permit. Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the system at project completion. Call at least 48 hours in advance to schedule inspection. Final approval will not be provided until all conditions are verified. If there are any questions please do not hesitate to call. Sincerely, I ue Mike Makela Assistant Fire Chief Arlington Fire Department OFFICE COPY 6231 :. P/N 15040 System Design Page 3A-26 3A.4.1.2 Module Perimeter Work Area Coverage, VPSB Module Volume: 2,720 ft.3 per nozzle,one or two TFP nozzles per IS45ABC Maximum Module Area: 217.6 ft.Zper nozzle for booths up to 20 fit.in height;* Maximum Module Height: 20 ft. Maximum Module Side Length: 16 ft. Maximum Nozzle Offset From Center of Wall: +/-10%of adjacent wall length *Note: Reference Coverage Table 3A-2 Table 3A-2: Module Perimeter Vehicle Paint Spray Booth Work Area Coverage ri16 Module Side 2,feet 13.60 14.00 14.50 15.00 15.50 16.00 16.00 15.54 15.00 14.50 14.03 13.60 15.38 14.94 14.42 13.94 13.49 13.07 14.28 13.87 13.39 12.95 12.53 12.14 13.33 12.95 12.50 12.08 11.69 11.33 12.50 12.14 11.72 11.33 10.96 10.62 17 11.76 11.42 11.03 10.6 6 10.32 10.00 1 18 11.11 10.79 10.42 10.07 9.74 9.44 19 10.52 10.22 9.87 9.54 9.23 8.94 20 1 10.00 9.71 9.37 9.06 8.77 8.50 [Dimensions inside of table are Side 1] Piping Re uirements: Piping diagrams include limitations on pipe length and fittings. System piping must be balanced. Balanced piping is that in which the difference between the shortest actual pipe length from the 1"tee to nozzle and the longest actual pipe length from the 1"tee to nozzle does not exceed 10%of the longest actual pipe length from tee to nozzle. The number and type of fittings for both tee to nozzle sections must be equal. All piping must be Schedule 40, hot-dipped galvanized steel pipe, and all fittings must be 1501b.class. Examples of acceptable fitting materials include hot-dipped galvanized malleable iron,ductile iron, or steel. Couplings and unions may be used where necessary, and reducing bushings or reducing tees can be used for changes in pipe diameter. Note: Black steel pipe and fittings can be used in relatively noncorrosive atmospheres. Nozzle Placement and Orientation: The TFP Nozzle has been developed to provide application of extinguishing agent from the upper perimeter of the module being protected. The nozzle is to be installed through the top of the module, at the closest point to the intersection of the module wall and module top. The nozzle location, laterally, is to be at the midpoint(+/- 10%)of the adjacent module edge. The tip of the nozzle must be within 6"of its entry point. The nozzle is to be installed vertically, with the orifices pointing downward, and the engraved arrow pointing into the protected module. The arrow must be aligned perpendicular to the adjacent wall, when viewed directly from below. Proper nozzle placement is shown as follows: Received UL Ex 5208 JUN 112020 April 9,2013 to:�>V-to i P/N 15040 System Design Page 3A-27 3A.4.1.2 Module Perimeter Work Area Coverage. VPSB (continued) 6" MAXIMUM FROM ENTRY POINT LOCATE NOZZLE WITHIN _ {-/- 10%OF MIDPOINT OF ADJACENT MODULE EDGE E I HEIGHT i LENGTH WIDTH i TFP NOZZLE AS VIEWED DIRECTLY FROM BELOW: GRiENTA.T ION, ARROW, IMUST 7-0'NT AWAY -ROV ADJACE\T MODULE EDGE 4 — ACJ.kCENT MCC�jLE EDGE + I � � 4 UL EX 5208 April 9,2013 I I P/N 15040 System Design Page 3A-12 3A.3.2 Module Perimeter Coverage, Total Flood (continued) LOCATE NOZZLE AT MIDPOINT OF ADJACENT MODULE EDGE 6�� MAXIMUM FROM ENTRY POINT i 8- MAXIMUM �- TO LATERAL ' MODULE / EDGE HEIGHT WIDTH LENGTH TFP NOZZLE AS VIEWED DIRECTLY FROM BELOW: ORIENTATION ARROW, MUST POINT AWAY FROM ADJACENT !MODULE EDGE 90' I 1117-;7 , 7) 11 UL EX 5208 April 9,2013 i P/N 15040 System Design Page 3A-13 3A.3.2 Module Perimeter Coverage,Total Flood (continued} f, �l i f i N lJ ZL1I e I t�i Module Perimeter Total Flooding,IS45ABC,Single TFP Nozzle: j Pipe Size,in Maximum Maximum #of Tees Length,ft. #of Elbows Allowed Cylinder to 1 40 6 0 Nozzle Total 1" Pipe -- 40 -- -L— — The maximum nozzle height above the agent cylinder is 12.5 feet. UL EX 5208 April 9,2013 P/N 15040 System Design Page 3A-14 3A.3.2 Module Perimeter Coverage Totai Flood (continued) 1 " Nozzle 1 " Nozzle Module Perimeter Total Flooding,IS45ABC,Two TFP Nozzles: Pipe Size, in Maximum Maximum #of Tees Length,ft #of Elbows Allowed Cylinder to T1 1 36 4 1 Ti to Nozzle 1 10 2 0 Total V Pipe 56 The maximum nozzle height above the agent cylinder is 12.5 feet. UL EX 5208 April 9,2013 r P/N 15040 / System Design Page 3A-15 3A.3.2 Module Perimeter Coverage,Total Flood continued) Below are Examples of Module Perimeter Total Flood Coverage Using the TFP Nozzle: r '27 Z 272 16' 16' 12.5' 25 I � 32' 27.2' 27.7 l 16' Neste: When "stacking" modules vertically, the maximum nozzle height above the cylin-dar is 12.5 f€'et. UL EX 5208 April 9,2013 P/N 15040 System Design Page 3A-34 3A.4.2 Plenum Coverage, VPSB 3A.4.2.1 Standard Plenum Coverage, VPSB Plenum Type Nozzle Dimensions Maximum Nozzle Location Nozzle Nozzle Used Per Nozzle Specifications Offset* Orientation LxWxH Backdraft(Option 1) TF I 4'x 15'x 10' Volume=600ft3 12"x 12"Square, W to 6" Vertical,Pointing Area=60ft2 Centered at Downward Side=15' Ceiling Backdraft(Option 2) TF 4'x 9'x 18' Volume=648ft' 12"x 12" 0"to 6" Vertical,Pointing x Area=36ft2 Square, Downward Side=9' Centered at Ceiling Pantleg TF 4'x 15'x 12' Volume=720ft' 12"x 12"Square, 0"to 6" Vertical,Pointing (Pantleg width Area=60ft2 Centered at Downward dimensions: Side=15' Ceiling 1'minimum to 3'maximum) Pit(Option 1) 3-Way 24'x 4'x 4' Volume=384ft3 Centered, Length, 0"to 6" Vertical,Pointing Area=96ft2 Width,and Downward;Two Side=24' Height of Plenum Opposite Side Holes Parallel to Longest Side Pit(Option 2) D/P 24'x 4'x 4' Volume=384ft' End, W to 6" Horizontal Area=96ft2 Centered Side=24' Pit with Tunnel 3-Way Pit:24'x 4'x 4' Volume=576ft' Centered, Y2 Pit Vertical,Pointing (Option 1) (Nozzle No Area=144ft2 Vertically; Height Downward;Each Further Than 12' Side=24' Centered,Length Side Hole Aligned From Either Pit of Pit;12"From Parallel with Pit End.) Start of Tunnel and Tunnel L Tunnel: Sections 12'x4'x4' Downdraft,Side 3-Way Plenum: Volume=640ft3 Centered,Length — Horizontal, Each Exhaust With Vertical 24'x 4'x'4' Area=96ft2 of Plenum; Side Hole Aligned Transition (Nozzle no Side=24' Centered, Parallel with Further Than 12' Width of Plenum; Plenum and From Either End Centered,Height Transition Sections of Plenum.) of Plenum Transition: 4'x4'x16'tall Under Floor TF 14'x 15'x 1' Volume=210ft3 Side-Entry; 0"to 6" Horizontal Area=210ft2 Centered, <> Side=15' Vertically; Centered, Lengthwise(t6") *Nozzle Offset is the maximum distance from the tip of the nozzle to the nearest edge of the protected zone. UL EX 5208 April 9,2013 i i P/N 15040 System Design Page 3A-35 3A.4.2.1 Standard Plenum Coverage,VPSB (continued) 1 24 m^P710N 2: o 24 NOZZLE 24' 4' PIT(1PiHIN 3-WAY Z NOZZLE 711 +. 12 \t x t, 4' 1 3—WAY y -1- N 4 0ZZL 2 _ Nozzle �. VI 4 � � 1 I t 2" _qA 2.4 r� r ti6ZZ I •+ -� �� r MAX. 1; NOZZLE t• I ' t '9' { 4� � 4. 4' 1'MIN.: 3'MAX. ,c• �\ 4 NOZZLE t— NOZZLE I / L/4 29 � I MAXIMUM 9OPT CN i11 MAXIMUM NOZZLE T JI t NOZZLE 1 _I R �,5� •9' I i MAXIMUMYl V 4.lC UL EX 5208 April 9,2013 i P/N 15040 System Design Page 3A-38 3A.4.3 Duct Coverage, VPSB The D/P Nozzle will protect either round or rectangular ducts up to 28 feet in length. Any change in duct direction or additional length requires an additional D/P nozzle. The duct nozzle must be centered at the duct entrance,pointed in the direction of air flow. The tip of the duct nozzle must be within 6"of the duct entrance. Round Ducts Maximum Diameter,Single Nozzle=46 Inches Rectaneular Ducts Maximurn Diameter,Two Nozzles=52 Inches The following table shows sample maximum rectangular (nozzle spacing: .5 x duct diameter, located on the dimensions, based on the following two requirements: same plane) Maximum Perimeter=144.5 Inches Maximum Diagonal =46 Inches Spacing for two nozzles,protecting a duct diameter larger than 46", up to 52"maximum Rectangular Ducts Side 1,Inches Side 2,Inches, Maximum 12 44.4 14 43.8 16 43.1 18 42.3 20 41.4 22 40.4 24 39.2 26 37.9 28 36.5 30 34.8 32 33.0 32.5 32.5 34 31.0 36 28.6 38 -25.9 40 22.7 42 18.7 44 13.4 UL EX 5208 April 9,2013 f I 1 I .� i 1 N❑TESi ALPINE FIRE TO INSTALL NEW AMEREX DRY CHEMICAL FIRE SUPPRESSION SYSTEM IN EXISTING PAINT BOOTH. 27'-0' BOOTH AREA ALL HOOD PENETRATI❑NS TO BE SEALED WITH UL LISTED QUIK-SEAL ADAPTERS. 13'-6' NOZZLE COVERAGE 13'-6' NOZZLE COVERAGE FIRE SUPPRESSION SYSTEM TO BE TIED INT❑ ALARM PANEL WHEN PRESENT. ALL LINK DETECTI❑N WILL COMPLY WITH NFPA33 & NFPA17 MANUAL PULL STATION TO BE LOCATED ALONG PATH OF EGRESS _ 'THERE SHALL BE NO DEVIATIONS FROM THE PLANS WITH❑UT APPROVAL FROM THE AUTH❑RITY HAVING JURISDICTION' II I II II EXISTING PANT LEG PLENUM AREA—I� II TOP OF ROOF a PAINT BOOTH AREA MAX AREA 15'x4'x12' I �+ II II I II DP E U v� w I rn EXHAUST FAN N IIQ N 3 TOTAL AMEREX JOB LINKS I II o IIQ z E3 om — 36'0 DUCTb6I o DP 36' DIAMETER DUCT a TOTAL FLOOD TOTAL FLOOD (1) DP NOZZLE ABOVE FA x PERIMETER PERIMETER (1) DP NOZZLE BELOW FA NOZZLE NOZZLE (1) TF NOZZLE CENTERED N PLENUM I 3'-0- x II � I II II � II i II 3/4'0 COVERS DP NOZZLE ABOVE FAN II TF II N❑TEi i 3/4'0 COVERS TF & DP NOZZLE II `PLENUM AREA TIME DELAY ASSEMBLY ALLOWS FOR PRE DISCHARGE HORN/STROBE TO ALERT PERSONNEL TO EVACUATE ALL CYLINDERS TO BE ACTUATED M �- w SIMULTANE❑USLY, WITH ONE _ CONTROL HEAD AND TIME DELAY. w f x D z = w F- J o a 0 AMEREX IS45 W/MRM AMEREX IS18 CYLINDERS w w CITY OF AR, INGTON PLAN VIEW Y 0 o BUILDING DEPARTMENT 13 Scale 3/8" = 1'-n" 3 APPROVED o� DATE to Z BY NO CHANGES AUTHORIZED FIRE SUPPRESSION PERMIT UNLILDINGNSPETOR PROJECT sTM TITLES :I T❑P OF FLO❑R BUILDING INSPECTOR A 7K1 1H AMEREX UL729 FIRE TOP SECRET SUPPRESSION SYSTEM . AP P�vC 3 �TM DATE. 06/09/2020 ��l COATINGS 735 E FAIRHAVEN, BURLINGT❑N WA SCALE, �,II _ S E C T I E N VIEW 18935 59TH AVE NE, 360-755-54443/8"= P-0" 4:1 �I�afte Svne l4 �UaO �� �� ARLINGTON,WA 98223 CONTRACTOR LIC# PYEBAFS807D❑ �E­ET 1 of 1 0krl;AS-� 1% F„n- puo�rf,.��,+ Scale 3/8 = 1 -0 Received )FFICECOPY JUN 112020 n 92uW 1y •� FIRE SPRINKLER PERMIT APPLICATION ItNIGV Department of Community & Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF COMPLETE AND SCALED PLANS, TWO (2) SETS OF HYDRAULIC CALCULATIONS, TWO (2) SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE SPRINKLER PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION. Type of Permit: ❑✓ New Fire Sprinkler ❑ Fire Sprinkler Add/Alt ❑ Underground Fire Line 18935 59TH AVE NE ARLINGTON WA Project Address: Parcel ID #: Project Valuation: 7900 Number of Heads: 5 Building Area(Sq Ft):0000 Owner: TOP SECRETCOAl1NGS Phone Number. 360-651-2540 Address: 18935 59TH AVE NE City:ARLINGTON State: WA Zip Code: 98223 Contact Person:NISHA TAYLOR Phone Number: 360-755-5444 Cell Phone: 360-610-9682 Email: taylorn@pyebarkerfire.com Address: PO BOX 265 City: BURLINGTON State: WA Z'.p Code:98233 Contractor: PYE BARKER FIRE Phone Number: 360-755-5444 Address: PO BOX 265 C;ty: BURLINGTON State: WA Zip Code: Contractor's License Number: PYEBAFS807DO Expiration:03/2022 Contact Person: N I S H A TAY LO R Email:taylorn@ pyeba rkerfire.com hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accordance with the laws,rules and regulation of the State of Washington. av_ee,es=oeo,9eseeoe =ea4�eoa�d 06/10/2020 Applicants Signature Date NISHA TAYLOR Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received WEB Forms—131 Page 1 of 1 6116LP NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY ®APPROVED PERMIT#: I AM PM DATE: JOB ADDRESS: 1-1;7"' q R u e ILOT#: PROJECT: I_p TYPE OF INSPECTION OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE Cl PLANNING Cl CIVIL O BUILDING CITY OF ARLINGTON v< NOTICE TO PERMITEE AND/OR OWNER PARTIAL APPROVAL X CORRECTIONS REQUIRED ❑ DO NOT OCCUPY ❑ APPROVED PERMIT#: 3 a a-Cv AM PM DATE: JOB ADDRESS: dCi= WJ135 5 1- Auc /V E LOT#: PROJECT: Secct-'� C_US�uN`s TYPE OF INSPECTION:Pa A OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑n/ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION Ace '04o.,c, 4,- 4- s, Pa r+bnof" S ,An r<sS C j cam. /Yi(A J 600-t-. A 0 A&+ 4,v un S, c4 eAn Ctc� ✓Q+, cA, � a e � rp v d, d no4 kj-I- of4 u on S C (AC+,441�� THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 e ,M'lcels �r II-�o�U INSPECTOR DATE PLANNING M CIVIL M BUILDING CITY OF ARLINGTON '� CITY OF ARLINGTON ` 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 18935 59th Avenue NE Permit#: 3226 Permit Expiration Date: 12/09/2020 Parcel#: 31051500401200 Valuation: 7900.00 OWNER APPLICANT CONTRACTOR City of Arlington Pye Barker Fire Pye Barker Fire 18204 59th Drive NE PO Box 265 PO Box 265 Arlington,WA 98223 Burlington,WA 98233 Burlington,WA 98233 360-755-5444 360-755-5444 LIC: PYEBAFS807DO EXP:03/20/2022 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Sprinkler CODE YEAR: 2015 STORIES: I CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for, or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law, or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/1RC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Zt� Signature Print Name Date Released By D A e CONDITIONS 1. Permit and set of approved plans to remain on site during installation.2. System shall be connected to fire alarm system per IFC 904.3.5. 3. A dual action manual pull station that activates the building fire alarm system shall be installed on the exterior of the spray booth.4.A horn strobe shall be installed on the exterior of the spray booth and shall operate upon activation of the spray booth fire suppression system. 5.Operation of the spray booth fire suppression system shall shut-off the exhaust fan.6.A nozzle cap blow-off test or similar test shall be conducted and witnessed by the Arlington Fire Department.7.Installation certification form to be completed and submitted prior to close out of permit. 8.Approved job copy shall be onsite for installation and inspection. 9.Adhere to approved plans 10.Call for inspections Items noted above are conditions of the permit and shall be verified as a part of the final inspection of the system at project completion.Final approval will not be provided until all conditions are verified.Call at least 48 hours in advance to schedule an inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 06/29/2020 Fire Sprinkler Permit $375.00 06/29/2020 Processing/Technology Fee $25.00 06/29/2020 Fire System Plan Review $147.31 Total Due: $547.31 Total Payment: $0.00 Balance Due: $547.31 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon BI FOLD DOORS O to �� n y y m�;u 14'-0' BOOTH AREA / NOZZLE COVERAGE z � Ob G� zx > � � > � N tZS'J y --I gym).Zm m i _ T mrC-) viz mm ("? tom" lJ o�� o�v �� i W T rDr z-4mm m /�1lJl =zz mmr- w m >cm ror�a z by�-.-< � o r d r(lo) C3 C-) N ^ d C3 mm n C-) M3 D C� VJ ��bd rlT'IGd 3 O 32m Cm -< m < m O �--170 z D v t7c m D x a O ii r m a O O m Z m D m < bd z) D D t7 4 3 z m CDD T m N �.�I m V x_ f �)Ln Z Cell Z_0-4 �(il bd , OmO -um .Zcl UI N.0--I D x N3D z0 J (min A mr tdZ I 00 Cl f 3 .Zl E3 I pa Ll % O o n 110 2 a D Q D zME3 m a� N m O I m 2 z r, D 3/4'0 m m m W ;'' a \ �r ti H eye C o m a � � co-mi rri m ~ 3/4'0 w F a 3 �� I I A c') m y� o F-- x w < o _ N ? m r c I � w O C) td i C3PYE•BARKER -< m Z (lo) NN 3 C3m v) N D D N 70 r x Z N v) TI m D� r �r m D Q° bd m m c-) O _ D L) O W .-�� m ---ON m r o TI �td td X m D N D '��� ?z > t7 C N z zzzC .x- x m m O O O n N N N N 1> N N N m r r r mmm D C-)bd D —m m bd — Zro m,o< om m,9-t � Lj— tdDD o z r m o z C3 — — — — c — — — — — ;v —3 BI FOLD DOORS D x D -9 D m D Z c a r .. r xro =m c r m r �� �z m a .r. 0 20 m Vi Z C p z 2 c D r td X Dm 0 2r r m m m a r � v, 9'-0' W❑RKING AREA BOOTH HEIGHT o z m D � o m t O O D C3Z o o Z 0 � 00 11'-0' OVERALL PLENUM HEIGHT cc z o i D sty E Z r �m � m V r td< c r 3 t'dD m C'I � O m O O W :c ZO 3 Z p -u bd m a (n n r m m m V J D m m n Z ;u D 70 C3m £ m r x l J p m 3 2 dro ty D r m z o W tj m w W D c m \ m D I~o Z a W D r 3 00 70 v) 2 Q' 3 r > �. D 0 �zl D r U Z m II ` w m o m D m td A O` SD 70 v v1 F- t7 C a 0 2 7C C z 0 A Q ` m TI -0 D m m D < A r Z D m r D 0 td m td z C m Z a C) ;u i C3 3 m v1 m 2 3 m Z P/N 15040 System Design Page 3A-26 3A.4.1.2 Module Perimeter Work Area Coverage, VPSB Module Volume: 2,720 ft.3 per nozzle, one or two TFP nozzles per IS45ABC Maximum Module Area: 217.6 ft.z per nozzle for booths up to 20 ft. in height;* Maximum Module Height: 20 ft. Maximum Module Side Length: 16 ft. Maximum Nozzle Offset From Center of Wall: +/- 10%of adjacent wall length *Note: Reference Coverage Table 3A-2 Table 3A-2: Module Perimeter Vehicle Paint Spray Booth Work Area Coverage Booth Height,Feet Module Side 2,feet 13.60 14.00 14.50 15.00 15.50 16.00 12.5 16.00 15.54 15.00 14.50 14.03 13.60 13 15.39 14.94 14.42 13.94 13.49 13.07 14 14.28 13.87 13.39 12.95 12.53 12.14 15 13.33 12.95 12.50 12.08 11.69 11.33 16 12.50 12.14 11.72 11.33 10.96 10.62 17 11.76 11.42 11.03 10.66 10.32 10.00 18 11.11 10.79 10.42 10.07 9.74 9.44 19 10.52 10.22 9.87 9.54 9.23 8.94 20 10.00 9.71 9.37 9.06 8.77 8.50 [Dimensions inside of table are Side 1] Piping Re uirements: Piping diagrams include limitations on pipe length and fittings. System piping must be balanced. Balanced piping is that in which the difference between the shortest actual pipe length from the 1"tee to nozzle and the longest actual pipe length from the 1"tee to nozzle does not exceed 10%of the longest actual pipe length from tee to nozzle. The number and type of fittings for both tee to nozzle sections must be equal. All piping must be Schedule 40, hot-dipped galvanized steel pipe,and all fittings must be 1501b.class. Examples of acceptable fitting materials include hot-dipped galvanized malleable iron,ductile iron,or steel. Couplings and unions may be used where necessary, and reducing bushings or reducing tees can be used for changes in pipe diameter. Note: Black steel pipe and fittings can be used in relatively noncorrosive atmospheres. Nozzle Placement and Orientation: The TFP Nozzle has been developed to provide application of extinguishing agent from the upper perimeter of the module being protected. The nozzle is to be installed through the top of the module, at the closest point to the intersection of the module wall and module top. The nozzle location, laterally, is to be at the midpoint(+/- 10%)of the adjacent module edge. The tip of the nozzle must be within 6"of its entry point. The nozzle is to be installed vertically, with the orifices pointing downward, and the engraved arrow pointing into the protected module. The arrow must be aligned perpendicular to the adjacent wall, when viewed directly from below. Proper nozzle placement is shown as follows: UL EX 5208 April 9,2013 P/N 15040 System Design Page 3A-27 3A.4.1.2 Module Perimeter Work Area Coverage, VPSB continued 6" MAXIMUM FROM ENTRY POINT LOCATE NOZZLE WITHIN +/- 10% OF MIDPOINT OF ADJACENT MODULE EDGE i I I i i HEIGHT i LENGTH WIDTH i j TFP NOZZLE AS VIEWED DIRECTLY FROM BELOW: ORithTA7[01\' ARROW, MLST P9NT AWAY --ROM ADJACENT MODULE EDGE I - 1- %— ACJkCENT MCD�tL= EDGE � I t UL EX 5208 April 9,2013 P/N 15040 System Design Page 3A-12 3A.3.2 Module Perimeter Coverage, Total Flood (continued) LOCATE NOZZLE AT MIDPOINT 6" MAXIMUM FROM OF ADJACENT MODULE EDGE ENTRY POINT e 8' MAXIMUM TO LATERAL MODULE EDGE HEIGHT WIDTH LENGTH TFP NOZZLE AS VIEWED DIRECTLY FROM BELOW: ORIENTATION ARROW, MUST POINT AWAY FROM ADJACENT MODULE EDGE 0 90* 01P0 4DJJkXI-1T U00UL!" UL EX 5208 April 9,2013 P/N 15040 System Design Page 3A-13 3A.3.2 Module Perimeter Covers a Total Flood continue r i i I i s I 4, Nozzle i Module Perimeter Total Flooding, IS45ABC,Single TFP Nozzle: Pipe Size,in Maximum Maximum #of Tees Length,ft. # of Elbows Allowed Cylinder to 1 40 6 0 Nozzle Total 1" Pipe -- 40 --The maximum nozzle height above the agent cylinder is 12.5 feet. UL EX 5208 April 9,2013 P/N 15040 System Design Page 3A-14 3A.3.2 Module Perimeter Coverage, Total Flood continued Nozzle Nozzle Module Perimeter Total Flooding, IS45ABC,Two TFP Nozzles: Pipe Size, in Maximum Maximum #of Tees Length,ft #of Elbows Allowed Cylinder to T1 1 36 4 1 T1 to Nozzle 1 10 2 0 Total 1" Pipe -- 56 --The maximum nozzle height above the agent cylinder is 12.5 feet. UL EX 5208 April 9, 2013 P/N 15040 System Design Page 3A-15 3Av3e2 Module Perimeter Coverage,Total Flood continued Below are Examples of Module Perimeter Total Flood Coverage Using the TFP nozzle: I 12 �' 12.5 272' 27-2' r; 16' l 12.5' 25' i 32' 27.2' 27.7 16' Note: When "stacking" modules vertically, the maximum nozzle height above the cylinder is 12.5 feet. UL EX 5208 April 9,2013 P/N 15040 System Design Page 3A-34 3A.4.2 Plenum Coverage, VPSB 3A.4.2.1 Standard Plenum Coverage, VPSB Plenum Type Nozzle Dimensions Maximum Nozzle Location Nozzle Nozzle t Used Per Nozzle Speclflcations Offset* Orientation LxWxH Backdraft(Option 1) TF 4'x 15'x 10' Volume=600ft 12"x 12"Square, 0"to 6" Vertical, Pointing Area=60ft2 Centered at Downward Side=15' Ceiling Backdraft(Option 2) TF 4'x 9'x 18' Volume=648ft3 12"x 12" 0"to 6" Vertical, Pointing x Area=36ft2 Square, Downward Side=9' Centered at. Ceiling Pantleg TF 4'x 15'x 12' Volume=720ft3 12"x 12"Square, 0"to 6" Vertical,Pointing (Pantleg width Area=60ft2 Centered at Downward dimensions: Side 15' Ceiling 1'minimum to 3'maximum) Pit(Option 1) 3-Way 24'x 4'x 4' Volume=384ft3 Centered, Length, 0"to 6" Vertical,Pointing Area=96ft2 Width,and Downward;Two r Side=24' Height of Plenum Opposite Side t Holes Parallel to Longest Side Pit(Option 2) D/P 24'x 4'x 4' Volume=384ft End, 0"to 6" Horizontal Area=96ft2 Centered Side=24' s Pit with Tunnel 3-Way Pit:24'x 4'x 4' Volume=576ft3 Centered, Yz Pit Vertical,Pointing (Option 1) (Nozzle No Area=144ft2 Vertically; Height Downward;Each Further Than 12' Side=24' Centered,Length Side Hole Aligned From Either Pit of Pit;12" From Parallel with Pit End.) Start of Tunnel and Tunnel Tunnel: Sections 12'x4'x4' Downdraft, Side 3-Way Plenum: Volume=640ft3 Centered, Length — Horizontal, Each Exhaust With Vertical 24'x 4'x'4' Area=96ft2 of Plenum; Side Hole Aligned Transition (Nozzle no Side 24' Centered, Parallel with Further Than 12' Width of Plenum; Plenum and From Either End Centered, Height Transition Sections of Plenum.) of Plenum Transition: 4'x 4'x 16'tall Under Floor TF 14'x 15'x V Volume=210ft3 Side-Entry; 0"to 6" Horizontal Area=210ftz Centered, Side=15' Vertically; <> Centered, Lengthwise(t6") *Nozzle Offset is the maximum distance from the tip of the nozzle to the nearest edge of the protected zone. UL EX 5208 April 9,2013 P/N 15040 System Design Page 3A-35 3A.4.2.1 Standard Plenum Coverage,VPSB continued I /24' PIT OPTION 2: p;p 24 NOZZLE i T 2,v j i I P7 OPTION J— 3-WAY NOZZLE 12 �4 T 4' 0 �4' j /P �. 3-WAY NOZZLLE/ / _2 '_ ` \�✓/IT NOZZLE y t 24' 24' �\ i N. NGZZ-E 4' 12' ; 3'MAX. / I T7 4 NyC ta' -� R E 24' \ / NOZZLE � I j I L/4 / \ \15' 4' i 28' HAXIMUM '9 I O MAXIMUM TF NOZZLE I ,L) TF NOZZLE ' i 5' MAXIMUM 4, UL EX 5208 April 9,2013 P/N 15040 System Design Page 3A-38 3A.4.3 Duct Coverage, VPSB The D/P Nozzle will protect either round or rectangular ducts up to 28 feet in length. Any change in duct direction or additional length requires an additional D/P nozzle. The duct nozzle must be centered at the duct entrance, pointed in the direction of air flow. The tip of the duct nozzle must be within 6"of the duct entrance. Round Ducts Maximum Diameter, Single Nozzle=46 Inches Rectangular Ducts Maximum Diameter,Two Nozzles =52 Inches The following table shows sample maximum rectangular (nozzle spacing: .5 x duct diameter, located on the dimensions, based on the following two requirements: same plane) Maximum Perimeter= 144.5 Inches Maximum Diagonal =46 Inches Spacing for two nozzles, protecting a duct diameter larger than 46", up to 52" maximum Rectangular Ducts Side 1,Inches Side 2, Inches, Maximum 12 44.4 14 43.8 16 43.1 18 42.3 20 41.4 22 40.4 24 39.2 26 37.9 28 36.5 ` 30 34.8 32 33.0 32.5 32.5 34 31.0 36 28.6 38 -25.9 40 22.7 42 18.7 44 13.4 UL EX 5208 April 9,2013 i i i 1 Date: 03/30/2026 Permit#: 3226 Permit 06/12/2020 Date: Review 06/12/2020 Date: Permit FIRE SPRINKLER Type: Review FIRE SPRINKLER Type: Target Date: 06/26/2020 Scheduled 00:00 Time: Completed 06/16/2020 Date: Description: 1. Permit and set of approved plans to remain on site during installation. 2. System shall be connected to fire alarm system per IFC 904.3.5. 3.A dual action manual pull station that activates the building fire alarm system shall be installed on the exterior of the spray booth. 4.A horn strobe shall be installed on the exterior of the spray booth and shall operate upon activation of the spray booth fire suppression system. 5. Operation of the spray booth fire suppression system shall shut-off the exhaust fan. 6.A nozzle cap blow-off test or similar test shall be conducted and witnessed by the Arlington Fire Department. 7. Installation certification form to be completed and submitted prior to close out of permit. Review Status: Assigned To: Mike Makela Time In: 00:00 Time Out: 00:00 Hours: 1.5 Notes 06/29/2020 1. Permit and set of approved plans to remain on site during installation. 2. System shall be connected to fire alarm system per IFC 904.3.5. 3.A dual action manual pull station that activates the building fire alarm system shall be installed on the exterior of the spray booth. 4.A horn strobe shall be installed on the exterior of the spray booth and shall operate upon activation of the spray booth fire suppression system. 5. Operation of the spray booth fire suppression system shall shut-off the exhaust fan. 6.A nozzle cap blow-off test or similar test shall be conducted and witnessed by the Arlington Fire Department. 7. Installation certification form to be completed and submitted prior to close out of permit. Property Information Parcel#: 31051500401200 City of Arlington City of Arlington 18204 59th Drive NE 18935 59th Avenue NE Arlington,WA 98223 Zoning: Lot: Block: Permit#: 3226 Permit Date: 06/12/20 Permit Type: FIRE SPRINKLER Project Name: Top Secret Coatings Applicant Name: Pye Barker Fire Applicant Address: PO Box 265 Applicant, City, State, Zip: Burlington,WA 98233 Contact: Nisha Taylor Phone: 360-755-5444 Email: taylorn@pyebarkerfire.com Scope of Work: Fire suppression for paint booth Valuation: 7900.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 07/01/2020 Permit Expires: 12/09/2020 Form Permit Type: Status: LASERFICHE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31051500401200 18935 59th Avenue NE City of Arlington Contractors Contractor Primary Contact Phone Address Contractor Type License License# Pye Barker Fire Nisha Taylor 360-755-5444 PO Box 265 CONSTRUCTION COA 604 541 987 CONTRACTOR CONSTRUCTION Labor and Pye Barker Fire Nisha Taylor 360-755-5444 PO Box 265 CONTRACTOR IndustriesPYEBAFS807DO Plan Reviews Date Review Type Description Assigned To Review Status 06/12/2020 FIRE SPRINKLER BUILDING 1.Permit and set of approved plans to remain on site during installation. 2.System shall be connected to fire alarm system per IFC 904.3.5. 3.A dual action manual pull station that activates the building fire alarm system shall be installed on the exterior of the spray booth. 4.A horn strobe shall be installed on the exterior of the 06/12/2020 FIRE SPRINKLER spray booth and shall operate upon activation of the spray Mike Makela booth fire suppression system. 5.Operation of the spray booth fire suppression system shall shut-off the exhaust fan. 6.A nozzle cap blow-off test or similar test shall be conducted and witnessed by the Arlington Fire Department. 7.Installation certification form to be completed and submitted prior to close out of permit. 06/12/2020 FIRE SPRINKLER PW-WAT-REV Fees Fee Description Notes Amount Fire Sprinkler System Commercial NFPA 13/13R $375.00 Processing/Technology $25.00 Fire System Plan Review Table 4-1 $147.31 Total $547.31 Attached Letters Date Letter Description 06/12/2020 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 07/01/2020 Pye Baker Fire&Safety 1009 Raelynn Jones $547.31 Outstanding Balance $0.00 Uploaded Files Date File Name 10/04/2021 9820077-3226 IC 11.6.2020.pdf 10/04/2021 9820078-3226 IC 8.11.2020.pdf 06/12/2020 6813477-3226 Application.pdf 06/12/2020 6813476-3226 Plans and Specifications.pdf