HomeMy WebLinkAbout18935 59th Avenue NE_BLD3226_2026 CITY OF ARLINGTON
18204 59th Avenue NE,Arlington,WA 98223
INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551
BUILDING PERMIT
18935 59th Avenue NE Permit#:3226
Permit Expiration Date 12/09/2020
Parcel#: 31051500401200 Valuation: 7900.00
OWNER APPLICANT CONTRACTOR
City of Arlington Pye Barker Fire Pye Barker Fire
18204 59th Drive NE PO Box 265 PO Box 265
Arlington,WA 98223 Burlington,WA 98233 Burlington,WA 98233
360-755-5444 360-755-5444
LIC: PYEBAFS807DO EXP:03/20/2022
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Fire Sprinkler CODE YEAR: 2015
STORIES: I CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any
other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the
Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any
period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance
advice or decision of the Governor of this State,this pen-nit shall not authorize such work and shall not be valid.The building
official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this
jurisdiction or any other ordinance or executive order of the City, or of any state or federal law,or of any order,proclamation,
guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is
determined to be issued in error-or on the basis of incorrect, inaccurate or incomplete information,or in violation of any City
ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor.
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK
AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE
OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND
ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN
MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRC110.
SALES TALC NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on
your sales tax return form and coded City of Arlington#3101.
C ZD
S gnature Print Natfic D•to Released By Da e
CONDITIONS
1. Pen-nit and set of approved plans to remain on site during installation. 2. System shall be connected to fire alarm system per
IFC 904.3.5. 3. A dual action manual pull station that activates the building fire alarm system shall be installed on the exterior of
tke spray booth.4.A horn strobe,, )be installed on the exterior of the spray bood- 1 shall operate upon activation of the
spray booth fire suppression system. 5.Operation of the spray booth fire suppression system shall shut-off the exhaust fan. 6.A
nozzle cap blow-off test or similar test shall be conducted and witnessed by the Arlington Fire Department. 7.Installation
certification form to be completed and submitted prior to close out of permit. 8.Approved job copy shall be onsite for installation
and inspection. 9.Adhere to approved plans 10. Call for inspections Items noted above are conditions of the permit and shall be
verified as a part of the final inspection of the system at project completion.Final approval will not be provided until all
conditions are verified. Call at least 48 hours in advance to schedule an inspection.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE
PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS,
MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
w
PERMIT FEES
Date Description Fee Amount
06/29/2020 Fire Sprinkler Permit $375.00
06/29/2020 Processing/Technology Fee $25.00
06/29/2020 Fire System Plan Review $147.31
Total Due: $547.31
Total Payment: $0.00
Balance Due: $547.31
CALL FOR INSPECTIONS
Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
�I
i
- �
r
f
Permit#: 3226 J4, I
Permit Date: 06/12/20
Project Name: Top Secret Coatings
Site Address: 18935 59th Avenue NE
Company/Applicant Name: Pye Barker Fire
Company/Applicant Address: PO Box 265
City, State, Zip: Burlington, WA 98233
Contact: Nisha Taylor
Phone: 360-755-5444
Email: taylorn@pyebarkerfire.com
Permit Type: Fire Sprinkler
Valuation: 7900.00
Square Feet: 0
Number of Stories: 0
Type of Construction:
Occupancy Type:
Scope of Work: Fire suppression for paint booth
MIC/Opportunity Zone:
Permit Issued:
Permit Expires: 12/09/2020
DNU:
Status: 1N PROCESS
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
31051500401200 18935 59th Avenue NE City of Arlington
Contractors
Contractor Primary Contact Phone Address Contractor Type License License#
Pye Barker Fire Nisha Taylor 360-755-5444 PO Box 265 CONTRACTOR Labor and PYEBAFS807DO
Industries
Plan Reviews
Date Review Type Description Assigned'To Review Status
06/12/2020 Fire Sprinkler Building in Review
06/12/2020 Fire Sprinkler Mike Makela In Review
06/12/2020 Fire Sprinkler PW-Wat-Rev In Review
�'
I
I
Uploaded Files
Date File Name
06/12/2020 6813477-3226 ppli ati n pdf
06/12/2020 6813476-3226 Plans and Speciticatiows.pdf
T
471�02'$,
FIRE SPRINKLER
PERMIT APPLICATION
Department of Community &Economic Development
City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551
THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF COMPLETE AND SCALED PLANS, TWO (2)
SETS OF HYDRAULIC CALCULATIONS, TWO (2) SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE
SPRINKLER PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO INCLUDE
SPECIFICATION SHEETS, WIRING DIAGRAMS (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON
ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION.
Type of Permit: ✓❑ New Fire Sprinkler ❑ Fire Sprinkler Add/Alt ❑ Underground Fire Line
18935 59TH AVE NE ARLINGTON WA
Project Address: Parcel ID#:
Project Valuation: 7900 Number of Heads: 5 Building Area(Sq Ft):0000
Owner: TOP SECRETCOAl1NGS Phone Number: 360-651-2540
Address: 18935 59TH AVE NE City:ARLINGTON State: WA Zip Code: 98223
Contact Person:NISHA TAYLOR Phone Number: 360-755-5444
Cell Phone: 360-610-9682 Email: taylorn@pyebarkerfire.com
Address: PO BOX 265 City:BURLINGTON State: WA Zip Code:98233
Contractor: PYE BARKER FIRE Phone Number: 360-755-5444
Address: PO BOX 265 City:BURLINGTON State: WA Zip Code:98233
Contractor's License Number: PYEBAFS807D0 Expiration:03/2022
Contact Person: Email: ar
NISHA TAYLOR taylorn@pyebkerf ire.corn
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-
described property will be in accordance with the laws,rules and regulation of the State of Washington.
1
��������1'f� 06/10/2020
Applicants Signature Date
NISHA TAYLOR
Print Applicants Name
FOR STAFF USE OIL Recelved
Y
(Ly.i� JUN,11 2020
Permit-# Accept By Amount Received Receipt# Date Received
WEB Forms—131 Page 1 of 1 6/16LP
_ 1 _ _ _
L&I regional offices are closed to public visits until further notice. Offices can still help you by phone from 8 a.m.to
5 p.m. weekdays (except state holidays). Use the phone number for your closest regional office
(ntt g:,n";.wa.gOV/ag_,„ „t.,<,,,,u„rri,- or you can call the Office of Information and Assistance at 360-902-5800.
O1YasNngfon$Idl1 Mp.rl�a�-I
Labor&Industries(htt s:!/Ini.wa.go).
PYE-BARKER FIRE AND SAFETY LLC
Owner or tradesperson PROCTOR,BARTON 11605 HAYNES BRIDGE RD
ALBERT ALPHARETTA,GA 30009
Principals 678-805.0155
PROCTOR,BARTON
ALBERT,PARTNER/MEMBER
■ TRAYLOR,JAMES HOWARD,AGENT
■ BRINKMAN,JASON LEE,AGENT
WA UBI No Business type
604 541 987 Limited Liability Company
License
Verify the contractor's active registration/license/certification(depending on trade)and any past violations.
Construction Contractor Active
Meets current requirements.
License specialties
FIRE PROTECT SYSTEM
License no.
PYEBAFS807DO
Effective—expiration
03/20/2020—03/20/2022
Bond
Platte River Ins Co $6,000.00
Bond account no
41426581
Received by L&I Effective date
03120/2020 03/09/2020
Expiration date
Until Canceled
Insurance
i
Everest Indemnity Ins Co $1,000,000.00
Policy no
51g1003490201 }
Received by L&I Effective date
03/20/2020 01/01/2020
Expiration date
01/01/2021 I
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts
may be recorded by other agencies.
License Violations
No license violations during the previous 6 year period.
Certifications & Endorsement:.
OMWBE Certifications
No active certifications exist for this business.
Apprentice Training Agent
o active Washington registered apprentices exist for this business.Washington allows the use of apprentices
registered with Oregon or Montana.Contact the Oregon Bureau of Labor&Industries or Montana Department of Labor
&Industry to verify If this business has apprentices.
Workers' Comp
No active workers'comp accounts during the previous 6 year period.
Public Works Requirements
Verify the contractor is eligible to perform work on public works projects.
Required Training—Effective July 1,2019
Completed the training on 4/28/2020
Contractor Strikes
No strikes have been issued against this contractor.
Contractors not allowed to bid
No debarments have been issued against this contractor.
Workplace Safety & Health
Check for any past safety and health violations found on jobsites this business was responsible for,
No inspections during the previous 6 year period.
.. .-�
r � ti
.. � �
ArlingtonCit of r
• • �::.l
7Fire Department
�L1NG
June 16, 2020
Permit Number: BLD 3226
Project Address: 6525 188th Street NE, Arlington
Project Description: Spray Booth Suppression System Plans for Top Secret Customs and Restoration
Contractor: Alpine Fire & Safety Systems
P.O. Box 265
Burlington, WA 98233
Re: Spray Booth Suppression System Shop Drawing Review Comments/Approval
The Arlington Fire Department has completed a review of the Fire Suppression shop drawing submittal and
approves the issuance of the permit with the following conditions:
Permit Conditions:
1. Permit and set of approved plans to remain on site during installation.
2. System shall be connected to fire alarm system per IFC 904.3.5.
3. A dual action manual pull station that activates the building fire alarm system shall be installed on the
exterior of the spray booth.
4. A horn strobe shall be installed on the exterior of the spray booth and shall operate upon activation of the
spray booth fire suppression system.
5. Operation of the spray booth fire suppression system shall shut-off the exhaust fan.
6. A nozzle cap blow-off test or similar test shall be conducted and witnessed by the Arlington Fire
Department.
7. Installation certification form to be completed and submitted prior to close out of permit.
Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the
system at project completion. Call at least 48 hours in advance to schedule inspection. Final approval will not
be provided until all conditions are verified.
If there are any questions please do not hesitate to call.
Sincerely,
I ue
Mike Makela
Assistant Fire Chief
Arlington Fire Department
OFFICE COPY
6231 :.
P/N 15040 System Design Page 3A-26
3A.4.1.2 Module Perimeter Work Area Coverage, VPSB
Module Volume: 2,720 ft.3 per nozzle,one or two TFP nozzles per IS45ABC
Maximum Module Area: 217.6 ft.Zper nozzle for booths up to 20 fit.in height;*
Maximum Module Height: 20 ft.
Maximum Module Side Length: 16 ft.
Maximum Nozzle Offset From Center of Wall: +/-10%of adjacent wall length
*Note: Reference Coverage Table 3A-2
Table 3A-2: Module Perimeter Vehicle Paint Spray Booth
Work Area Coverage
ri16
Module Side 2,feet
13.60 14.00 14.50 15.00 15.50 16.00
16.00 15.54 15.00 14.50 14.03 13.60
15.38 14.94 14.42 13.94 13.49 13.07
14.28 13.87 13.39 12.95 12.53 12.14
13.33 12.95 12.50 12.08 11.69 11.33
12.50 12.14 11.72 11.33 10.96 10.62
17 11.76 11.42 11.03 10.6 6 10.32 10.00
1 18 11.11 10.79 10.42 10.07 9.74 9.44
19 10.52 10.22 9.87 9.54 9.23 8.94
20 1 10.00 9.71 9.37 9.06 8.77 8.50
[Dimensions inside of table are Side 1]
Piping Re uirements:
Piping diagrams include limitations on pipe length and fittings. System piping must be balanced. Balanced piping is
that in which the difference between the shortest actual pipe length from the 1"tee to nozzle and the longest actual
pipe length from the 1"tee to nozzle does not exceed 10%of the longest actual pipe length from tee to nozzle. The
number and type of fittings for both tee to nozzle sections must be equal.
All piping must be Schedule 40, hot-dipped galvanized steel pipe, and all fittings must be 1501b.class. Examples of
acceptable fitting materials include hot-dipped galvanized malleable iron,ductile iron, or steel. Couplings and unions
may be used where necessary, and reducing bushings or reducing tees can be used for changes in pipe diameter.
Note: Black steel pipe and fittings can be used in relatively noncorrosive atmospheres.
Nozzle Placement and Orientation:
The TFP Nozzle has been developed to provide application of extinguishing agent from the upper perimeter of the
module being protected. The nozzle is to be installed through the top of the module, at the closest point to the
intersection of the module wall and module top. The nozzle location, laterally, is to be at the midpoint(+/- 10%)of the
adjacent module edge. The tip of the nozzle must be within 6"of its entry point. The nozzle is to be installed vertically,
with the orifices pointing downward, and the engraved arrow pointing into the protected module. The arrow must be
aligned perpendicular to the adjacent wall, when viewed directly from below. Proper nozzle placement is shown as
follows:
Received
UL Ex 5208 JUN 112020 April 9,2013
to:�>V-to
i
P/N 15040 System Design Page 3A-27
3A.4.1.2 Module Perimeter Work Area Coverage. VPSB (continued)
6" MAXIMUM FROM
ENTRY POINT
LOCATE NOZZLE WITHIN _
{-/- 10%OF MIDPOINT OF
ADJACENT MODULE EDGE
E
I
HEIGHT
i
LENGTH
WIDTH i
TFP NOZZLE AS VIEWED DIRECTLY FROM BELOW:
GRiENTA.T ION, ARROW,
IMUST 7-0'NT AWAY -ROV
ADJACE\T MODULE EDGE
4
— ACJ.kCENT MCC�jLE EDGE
+ I �
� 4
UL EX 5208 April 9,2013
I
I
P/N 15040 System Design Page 3A-12
3A.3.2 Module Perimeter Coverage, Total Flood (continued)
LOCATE NOZZLE AT MIDPOINT
OF ADJACENT MODULE EDGE 6�� MAXIMUM FROM
ENTRY POINT
i
8- MAXIMUM �-
TO LATERAL '
MODULE /
EDGE
HEIGHT
WIDTH LENGTH
TFP NOZZLE AS VIEWED DIRECTLY FROM BELOW:
ORIENTATION ARROW,
MUST POINT AWAY FROM
ADJACENT !MODULE EDGE
90'
I
1117-;7
, 7) 11
UL EX 5208
April 9,2013
i
P/N 15040 System Design Page 3A-13
3A.3.2 Module Perimeter Coverage,Total Flood (continued}
f,
�l
i
f
i
N lJ ZL1I e
I
t�i
Module Perimeter Total Flooding,IS45ABC,Single TFP Nozzle: j
Pipe Size,in Maximum Maximum #of Tees
Length,ft. #of Elbows Allowed
Cylinder to 1 40 6 0
Nozzle
Total 1" Pipe -- 40 --
-L— —
The maximum nozzle height above the agent cylinder is 12.5 feet.
UL EX 5208 April 9,2013
P/N 15040 System Design
Page 3A-14
3A.3.2 Module Perimeter Coverage Totai Flood (continued)
1 "
Nozzle
1 "
Nozzle
Module Perimeter Total Flooding,IS45ABC,Two TFP Nozzles:
Pipe Size, in Maximum Maximum #of Tees
Length,ft #of Elbows Allowed
Cylinder to T1 1 36 4 1
Ti to Nozzle 1 10 2 0
Total V Pipe 56
The maximum nozzle height above the agent cylinder is 12.5 feet.
UL EX 5208
April 9,2013
r
P/N 15040 / System Design Page 3A-15
3A.3.2 Module Perimeter Coverage,Total Flood continued)
Below are Examples of Module Perimeter Total Flood Coverage Using the TFP Nozzle:
r
'27 Z 272
16' 16'
12.5'
25 I �
32'
27.2' 27.7
l 16'
Neste: When "stacking" modules vertically, the maximum nozzle height above the cylin-dar is 12.5
f€'et.
UL EX 5208 April 9,2013
P/N 15040 System Design Page 3A-34
3A.4.2 Plenum Coverage, VPSB
3A.4.2.1 Standard Plenum Coverage, VPSB
Plenum Type Nozzle Dimensions Maximum Nozzle Location Nozzle Nozzle
Used Per Nozzle Specifications Offset* Orientation
LxWxH
Backdraft(Option 1) TF I 4'x 15'x 10' Volume=600ft3 12"x 12"Square, W to 6" Vertical,Pointing
Area=60ft2 Centered at Downward
Side=15' Ceiling
Backdraft(Option 2) TF 4'x 9'x 18' Volume=648ft' 12"x 12" 0"to 6" Vertical,Pointing
x
Area=36ft2 Square, Downward
Side=9' Centered at
Ceiling
Pantleg TF 4'x 15'x 12' Volume=720ft' 12"x 12"Square, 0"to 6" Vertical,Pointing
(Pantleg width Area=60ft2 Centered at Downward
dimensions: Side=15' Ceiling
1'minimum to
3'maximum)
Pit(Option 1) 3-Way 24'x 4'x 4' Volume=384ft3 Centered, Length, 0"to 6" Vertical,Pointing
Area=96ft2 Width,and Downward;Two
Side=24' Height of Plenum Opposite Side
Holes Parallel to
Longest Side
Pit(Option 2) D/P 24'x 4'x 4' Volume=384ft' End, W to 6" Horizontal
Area=96ft2 Centered
Side=24'
Pit with Tunnel 3-Way Pit:24'x 4'x 4' Volume=576ft' Centered, Y2 Pit Vertical,Pointing
(Option 1) (Nozzle No Area=144ft2 Vertically; Height Downward;Each
Further Than 12' Side=24' Centered,Length Side Hole Aligned
From Either Pit of Pit;12"From Parallel with Pit
End.) Start of Tunnel and Tunnel
L Tunnel: Sections
12'x4'x4'
Downdraft,Side 3-Way Plenum: Volume=640ft3 Centered,Length — Horizontal, Each
Exhaust With Vertical 24'x 4'x'4' Area=96ft2 of Plenum; Side Hole Aligned
Transition (Nozzle no Side=24' Centered, Parallel with
Further Than 12' Width of Plenum; Plenum and
From Either End Centered,Height Transition Sections
of Plenum.) of Plenum
Transition:
4'x4'x16'tall
Under Floor TF 14'x 15'x 1' Volume=210ft3 Side-Entry; 0"to 6" Horizontal
Area=210ft2 Centered,
<> Side=15' Vertically;
Centered,
Lengthwise(t6")
*Nozzle Offset is the maximum distance from the tip of the nozzle to the nearest edge of the protected zone.
UL EX 5208
April 9,2013
i
i
P/N 15040 System Design Page 3A-35
3A.4.2.1 Standard Plenum Coverage,VPSB (continued)
1
24
m^P710N 2:
o
24
NOZZLE
24' 4' PIT(1PiHIN
3-WAY
Z NOZZLE 711
+.
12
\t x
t,
4' 1
3—WAY y -1- N 4 0ZZL
2 _
Nozzle �.
VI
4 � �
1
I
t
2"
_qA 2.4 r� r
ti6ZZ I •+ -� ��
r
MAX. 1;
NOZZLE t• I ' t '9'
{ 4�
� 4. 4'
1'MIN.:
3'MAX.
,c• �\ 4 NOZZLE t—
NOZZLE
I
/ L/4
29 � I
MAXIMUM 9OPT CN
i11
MAXIMUM
NOZZLE
T JI
t NOZZLE 1 _I
R
�,5� •9' I i
MAXIMUMYl
V 4.lC
UL EX 5208 April 9,2013
i
P/N 15040 System Design
Page 3A-38
3A.4.3 Duct Coverage, VPSB
The D/P Nozzle will protect either round or rectangular ducts up to 28 feet in length. Any change in duct direction or
additional length requires an additional D/P nozzle. The duct nozzle must be centered at the duct entrance,pointed in
the direction of air flow. The tip of the duct nozzle must be within 6"of the duct entrance.
Round Ducts
Maximum Diameter,Single Nozzle=46 Inches Rectaneular Ducts
Maximurn Diameter,Two Nozzles=52 Inches The following table shows sample maximum rectangular
(nozzle spacing: .5 x duct diameter, located on the dimensions, based on the following two requirements:
same plane) Maximum Perimeter=144.5 Inches
Maximum Diagonal =46 Inches
Spacing for two nozzles,protecting a duct
diameter larger than 46", up to 52"maximum Rectangular Ducts
Side 1,Inches Side 2,Inches,
Maximum
12 44.4
14 43.8
16 43.1
18 42.3
20 41.4
22 40.4
24 39.2
26 37.9
28 36.5
30 34.8
32 33.0
32.5 32.5
34 31.0
36 28.6
38 -25.9
40 22.7
42 18.7
44 13.4
UL EX 5208
April 9,2013
f
I
1
I
.�
i
1
N❑TESi
ALPINE FIRE TO INSTALL NEW AMEREX DRY CHEMICAL FIRE SUPPRESSION SYSTEM IN
EXISTING PAINT BOOTH.
27'-0' BOOTH AREA ALL HOOD PENETRATI❑NS TO BE SEALED WITH UL LISTED QUIK-SEAL ADAPTERS.
13'-6' NOZZLE COVERAGE 13'-6' NOZZLE COVERAGE FIRE SUPPRESSION SYSTEM TO BE TIED INT❑ ALARM PANEL WHEN PRESENT.
ALL LINK DETECTI❑N WILL COMPLY WITH NFPA33 & NFPA17
MANUAL PULL STATION TO BE LOCATED ALONG PATH OF EGRESS _
'THERE SHALL BE NO DEVIATIONS FROM THE PLANS WITH❑UT APPROVAL FROM THE
AUTH❑RITY HAVING JURISDICTION'
II I
II II
EXISTING PANT LEG PLENUM AREA—I� II TOP OF ROOF
a PAINT BOOTH AREA MAX AREA 15'x4'x12' I �+
II II I II DP E
U
v� w I rn EXHAUST FAN
N
IIQ N 3 TOTAL AMEREX JOB LINKS I II o
IIQ
z
E3 om — 36'0 DUCTb6I o DP 36' DIAMETER DUCT
a TOTAL FLOOD TOTAL FLOOD (1) DP NOZZLE ABOVE FA
x PERIMETER PERIMETER (1) DP NOZZLE BELOW FA
NOZZLE NOZZLE (1) TF NOZZLE CENTERED N PLENUM I 3'-0-
x
II � I II
II � II
i
II 3/4'0 COVERS DP NOZZLE ABOVE FAN II TF
II N❑TEi i 3/4'0 COVERS TF & DP NOZZLE II `PLENUM AREA
TIME DELAY ASSEMBLY ALLOWS
FOR PRE DISCHARGE
HORN/STROBE TO ALERT
PERSONNEL TO EVACUATE
ALL CYLINDERS TO BE ACTUATED M �- w
SIMULTANE❑USLY, WITH ONE _
CONTROL HEAD AND TIME DELAY. w f
x D
z
= w
F- J
o a
0
AMEREX IS45 W/MRM
AMEREX IS18 CYLINDERS w w
CITY OF AR, INGTON
PLAN VIEW Y 0 o BUILDING DEPARTMENT
13
Scale 3/8" = 1'-n" 3 APPROVED
o�
DATE to Z BY
NO CHANGES AUTHORIZED
FIRE SUPPRESSION PERMIT UNLILDINGNSPETOR
PROJECT sTM TITLES :I
T❑P OF FLO❑R BUILDING INSPECTOR
A 7K1 1H AMEREX UL729 FIRE
TOP SECRET SUPPRESSION SYSTEM . AP P�vC 3
�TM DATE. 06/09/2020 ��l
COATINGS 735 E FAIRHAVEN, BURLINGT❑N WA SCALE, �,II _ S E C T I E N VIEW
18935 59TH AVE NE, 360-755-54443/8"= P-0" 4:1 �I�afte Svne l4 �UaO �� ��
ARLINGTON,WA 98223 CONTRACTOR LIC# PYEBAFS807D❑ �EET
1 of 1 0krl;AS-� 1% F„n- puo�rf,.��,+ Scale 3/8 = 1 -0 Received
)FFICECOPY JUN 112020
n 92uW
1y •� FIRE SPRINKLER
PERMIT APPLICATION
ItNIGV Department of Community & Economic Development
City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551
THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF COMPLETE AND SCALED PLANS, TWO (2)
SETS OF HYDRAULIC CALCULATIONS, TWO (2) SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE
SPRINKLER PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO INCLUDE
SPECIFICATION SHEETS, WIRING DIAGRAMS (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON
ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION.
Type of Permit: ❑✓ New Fire Sprinkler ❑ Fire Sprinkler Add/Alt ❑ Underground Fire Line
18935 59TH AVE NE ARLINGTON WA
Project Address: Parcel ID #:
Project Valuation: 7900 Number of Heads: 5 Building Area(Sq Ft):0000
Owner: TOP SECRETCOAl1NGS Phone Number. 360-651-2540
Address: 18935 59TH AVE NE City:ARLINGTON State: WA Zip Code: 98223
Contact Person:NISHA TAYLOR Phone Number: 360-755-5444
Cell Phone: 360-610-9682 Email: taylorn@pyebarkerfire.com
Address: PO BOX 265 City: BURLINGTON State: WA Z'.p Code:98233
Contractor: PYE BARKER FIRE Phone Number: 360-755-5444
Address: PO BOX 265 C;ty: BURLINGTON State: WA Zip Code:
Contractor's License Number: PYEBAFS807DO Expiration:03/2022
Contact Person:
N I S H A TAY LO R Email:taylorn@ pyeba rkerfire.com
hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-
described property will be in accordance with the laws,rules and regulation of the State of Washington.
av_ee,es=oeo,9eseeoe =ea4�eoa�d 06/10/2020
Applicants Signature Date
NISHA TAYLOR
Print Applicants Name
FOR STAFF USE ONLY
Permit# Accepted By Amount Received Receipt# Date Received
WEB Forms—131 Page 1 of 1 6116LP
NOTICE
TO PERMITEE AND/OR OWNER
❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED
❑ DO NOT OCCUPY ®APPROVED
PERMIT#: I AM PM DATE:
JOB ADDRESS: 1-1;7"' q R u e ILOT#:
PROJECT: I_p
TYPE OF INSPECTION
OTHER:
❑ NO PERMIT-STOP WORK-OBTAIN PERMIT
❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND
PERMIT -STOP WORK
❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR.
❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE
APPROVED.
❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE(PER IBC)
MUST BE PAID PRIOR TO NEXT INSPECTION.
❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION
THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR
PENALTIES IMPOSED BYLAW MAYAPPLY.
FOR INSPECTION CALL: 360-403-3417
INSPECTOR DATE
Cl PLANNING Cl CIVIL O BUILDING CITY OF ARLINGTON
v<
NOTICE
TO PERMITEE AND/OR OWNER
PARTIAL APPROVAL X CORRECTIONS REQUIRED
❑ DO NOT OCCUPY ❑ APPROVED
PERMIT#: 3 a a-Cv AM PM DATE:
JOB ADDRESS: dCi= WJ135 5 1- Auc /V E LOT#:
PROJECT: Secct-'� C_US�uN`s
TYPE OF INSPECTION:Pa A
OTHER:
❑ NO PERMIT-STOP WORK-OBTAIN PERMIT
❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND
PERMIT -STOP WORK
❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR.
CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE
APPROVED.
❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE (PER IBC)
MUST BE PAID PRIOR TO NEXT INSPECTION.
❑n/ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION
Ace '04o.,c, 4,- 4- s, Pa r+bnof" S ,An r<sS
C j cam. /Yi(A J
600-t-. A 0 A&+
4,v un S, c4 eAn Ctc� ✓Q+, cA,
� a e � rp v d, d no4 kj-I- of4 u on S C
(AC+,441��
THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR
PENALTIES IMPOSED BY LAW MAYAPPLY.
FOR INSPECTION CALL: 360-403-3417
e ,M'lcels �r II-�o�U
INSPECTOR DATE
PLANNING M CIVIL M BUILDING CITY OF ARLINGTON
'� CITY
OF ARLINGTON
` 18204 59th Avenue NE,Arlington,WA 98223
INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551
BUILDING PERMIT
18935 59th Avenue NE Permit#: 3226
Permit Expiration Date: 12/09/2020
Parcel#: 31051500401200 Valuation: 7900.00
OWNER APPLICANT CONTRACTOR
City of Arlington Pye Barker Fire Pye Barker Fire
18204 59th Drive NE PO Box 265 PO Box 265
Arlington,WA 98223 Burlington,WA 98233 Burlington,WA 98233
360-755-5444 360-755-5444
LIC: PYEBAFS807DO EXP:03/20/2022
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Fire Sprinkler CODE YEAR: 2015
STORIES: I CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
The issuance or granting of this permit shall not be construed to be a permit for, or approval of,any violation of this Code or any
other ordinance or order of the City,of any state or federal law, or of any order,proclamation,guidance advice or decision of the
Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any
period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance
advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building
official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this
jurisdiction or any other ordinance or executive order of the City,or of any state or federal law, or of any order, proclamation,
guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is
determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City
ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor.
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK
AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE
OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND
ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN
MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/1RC110.
SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on
your sales tax return form and coded City of Arlington#3101.
Zt�
Signature Print Name Date Released By D A e
CONDITIONS
1. Permit and set of approved plans to remain on site during installation.2. System shall be connected to fire alarm system per
IFC 904.3.5. 3. A dual action manual pull station that activates the building fire alarm system shall be installed on the exterior of
the spray booth.4.A horn strobe shall be installed on the exterior of the spray booth and shall operate upon activation of the
spray booth fire suppression system. 5.Operation of the spray booth fire suppression system shall shut-off the exhaust fan.6.A
nozzle cap blow-off test or similar test shall be conducted and witnessed by the Arlington Fire Department.7.Installation
certification form to be completed and submitted prior to close out of permit. 8.Approved job copy shall be onsite for installation
and inspection. 9.Adhere to approved plans 10.Call for inspections Items noted above are conditions of the permit and shall be
verified as a part of the final inspection of the system at project completion.Final approval will not be provided until all
conditions are verified.Call at least 48 hours in advance to schedule an inspection.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE
PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS,
MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
06/29/2020 Fire Sprinkler Permit $375.00
06/29/2020 Processing/Technology Fee $25.00
06/29/2020 Fire System Plan Review $147.31
Total Due: $547.31
Total Payment: $0.00
Balance Due: $547.31
CALL FOR INSPECTIONS
Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
BI FOLD DOORS
O
to ��
n
y y m�;u 14'-0' BOOTH AREA / NOZZLE COVERAGE
z � Ob
G�
zx > � �
> �
N tZS'J y --I gym).Zm m i _
T mrC-) viz mm ("?
tom" lJ o�� o�v �� i
W T rDr z-4mm m
/�1lJl =zz mmr- w
m >cm ror�a z
by�-.-< � o
r d r(lo) C3 C-) N
^ d C3
mm
n C-) M3 D C�
VJ ��bd rlT'IGd 3 O
32m Cm -< m <
m
O �--170
z
D
v t7c m D x a
O ii r m a O O m
Z m D m < bd
z)
D D t7
4 3 z
m
CDD T m N
�.�I m V x_ f
�)Ln Z
Cell Z_0-4
�(il bd , OmO -um
.Zcl UI N.0--I D x
N3D z0
J
(min A mr tdZ I
00 Cl f 3 .Zl E3 I pa Ll %
O
o n 110 2 a
D
Q D zME3 m a�
N m O I m 2
z r,
D
3/4'0 m m m
W ;'' a
\ �r
ti H eye C o
m a � � co-mi rri m ~ 3/4'0 w
F a
3
�� I I A c')
m
y� o
F-- x w <
o _ N ? m
r
c I � w
O C) td i
C3PYE•BARKER -<
m
Z (lo) NN 3 C3m v) N D D N
70 r x Z N
v) TI m D� r
�r m
D
Q° bd m m c-)
O _ D L) O
W .-��
m ---ON m
r
o TI �td td X m D
N D '��� ?z >
t7 C
N z zzzC .x- x m
m O O O n N
N N N 1>
N N N m
r r r mmm D
C-)bd D
—m m bd —
Zro
m,o<
om
m,9-t
� Lj— tdDD
o z
r m
o z
C3 — — — — c — — — — —
;v —3
BI FOLD DOORS D x D -9 D m D Z
c a r .. r xro
=m c r m r ��
�z
m a .r. 0 20 m Vi
Z C p z
2 c
D r td X Dm
0 2r r m m m
a r � v,
9'-0' W❑RKING AREA BOOTH HEIGHT o z m D � o m t
O O D C3Z
o o Z 0 � 00
11'-0' OVERALL PLENUM HEIGHT cc z o i D
sty E Z r
�m � m V r
td< c r 3
t'dD m C'I � O m
O O W :c
ZO 3
Z p -u bd m a
(n n r m m m
V J D m m
n Z ;u D 70
C3m £ m r x
l J p m 3 2 dro
ty
D
r m z o
W tj
m w W D c m
\ m D I~o Z a W D r 3
00 70
v) 2 Q' 3 r >
�. D
0 �zl D r
U Z m
II ` w m o m D m td A
O` SD 70 v v1
F- t7 C a 0 2 7C C
z 0 A
Q ` m TI -0 D m
m D < A r
Z D m
r D 0
td m td z
C m Z a
C) ;u
i C3
3 m v1
m
2 3
m
Z
P/N 15040 System Design Page 3A-26
3A.4.1.2 Module Perimeter Work Area Coverage, VPSB
Module Volume: 2,720 ft.3 per nozzle, one or two TFP nozzles per IS45ABC
Maximum Module Area: 217.6 ft.z per nozzle for booths up to 20 ft. in height;*
Maximum Module Height: 20 ft.
Maximum Module Side Length: 16 ft.
Maximum Nozzle Offset From Center of Wall: +/- 10%of adjacent wall length
*Note: Reference Coverage Table 3A-2
Table 3A-2: Module Perimeter Vehicle Paint Spray Booth
Work Area Coverage
Booth Height,Feet Module Side 2,feet
13.60 14.00 14.50 15.00 15.50 16.00
12.5 16.00 15.54 15.00 14.50 14.03 13.60
13 15.39 14.94 14.42 13.94 13.49 13.07
14 14.28 13.87 13.39 12.95 12.53 12.14
15 13.33 12.95 12.50 12.08 11.69 11.33
16 12.50 12.14 11.72 11.33 10.96 10.62
17 11.76 11.42 11.03 10.66 10.32 10.00
18 11.11 10.79 10.42 10.07 9.74 9.44
19 10.52 10.22 9.87 9.54 9.23 8.94
20 10.00 9.71 9.37 9.06 8.77 8.50
[Dimensions inside of table are Side 1]
Piping Re uirements:
Piping diagrams include limitations on pipe length and fittings. System piping must be balanced. Balanced piping is
that in which the difference between the shortest actual pipe length from the 1"tee to nozzle and the longest actual
pipe length from the 1"tee to nozzle does not exceed 10%of the longest actual pipe length from tee to nozzle. The
number and type of fittings for both tee to nozzle sections must be equal.
All piping must be Schedule 40, hot-dipped galvanized steel pipe,and all fittings must be 1501b.class. Examples of
acceptable fitting materials include hot-dipped galvanized malleable iron,ductile iron,or steel. Couplings and unions
may be used where necessary, and reducing bushings or reducing tees can be used for changes in pipe diameter.
Note: Black steel pipe and fittings can be used in relatively noncorrosive atmospheres.
Nozzle Placement and Orientation:
The TFP Nozzle has been developed to provide application of extinguishing agent from the upper perimeter of the
module being protected. The nozzle is to be installed through the top of the module, at the closest point to the
intersection of the module wall and module top. The nozzle location, laterally, is to be at the midpoint(+/- 10%)of the
adjacent module edge. The tip of the nozzle must be within 6"of its entry point. The nozzle is to be installed vertically,
with the orifices pointing downward, and the engraved arrow pointing into the protected module. The arrow must be
aligned perpendicular to the adjacent wall, when viewed directly from below. Proper nozzle placement is shown as
follows:
UL EX 5208 April 9,2013
P/N 15040 System Design Page 3A-27
3A.4.1.2 Module Perimeter Work Area Coverage, VPSB continued
6" MAXIMUM FROM
ENTRY POINT
LOCATE NOZZLE WITHIN
+/- 10% OF MIDPOINT OF
ADJACENT MODULE EDGE
i
I I
i
i
HEIGHT
i
LENGTH
WIDTH
i
j TFP NOZZLE AS VIEWED DIRECTLY FROM BELOW:
ORithTA7[01\' ARROW,
MLST P9NT AWAY --ROM
ADJACENT MODULE EDGE
I
- 1-
%— ACJkCENT MCD�tL= EDGE
� I
t
UL EX 5208 April 9,2013
P/N 15040 System Design Page 3A-12
3A.3.2 Module Perimeter Coverage, Total Flood (continued)
LOCATE NOZZLE AT MIDPOINT 6" MAXIMUM FROM
OF ADJACENT MODULE EDGE ENTRY POINT
e
8' MAXIMUM
TO LATERAL
MODULE
EDGE
HEIGHT
WIDTH LENGTH
TFP NOZZLE AS VIEWED DIRECTLY FROM BELOW:
ORIENTATION ARROW,
MUST POINT AWAY FROM
ADJACENT MODULE EDGE
0
90* 01P0
4DJJkXI-1T U00UL!"
UL EX 5208 April 9,2013
P/N 15040 System Design Page 3A-13
3A.3.2 Module Perimeter Covers a Total Flood continue
r
i
i
I
i
s
I
4,
Nozzle
i
Module Perimeter Total Flooding, IS45ABC,Single TFP Nozzle:
Pipe Size,in Maximum Maximum #of Tees
Length,ft. # of Elbows Allowed
Cylinder to 1 40 6 0
Nozzle
Total 1" Pipe -- 40 --The maximum nozzle height above the agent cylinder is 12.5 feet.
UL EX 5208 April 9,2013
P/N 15040 System Design Page 3A-14
3A.3.2 Module Perimeter Coverage, Total Flood continued
Nozzle
Nozzle
Module Perimeter Total Flooding, IS45ABC,Two TFP Nozzles:
Pipe Size, in Maximum Maximum #of Tees
Length,ft #of Elbows Allowed
Cylinder to T1 1 36 4 1
T1 to Nozzle 1 10 2 0
Total 1" Pipe -- 56 --The maximum nozzle height above the agent cylinder is 12.5 feet.
UL EX 5208
April 9, 2013
P/N 15040 System Design Page 3A-15
3Av3e2 Module Perimeter Coverage,Total Flood continued
Below are Examples of Module Perimeter Total Flood Coverage Using the TFP nozzle:
I
12 �'
12.5
272' 27-2'
r; 16'
l
12.5'
25' i
32'
27.2' 27.7
16'
Note: When "stacking" modules vertically, the maximum nozzle height above the cylinder is 12.5
feet.
UL EX 5208 April 9,2013
P/N 15040 System Design Page 3A-34
3A.4.2 Plenum Coverage, VPSB
3A.4.2.1 Standard Plenum Coverage, VPSB
Plenum Type Nozzle Dimensions Maximum Nozzle Location Nozzle Nozzle
t Used Per Nozzle Speclflcations Offset* Orientation
LxWxH
Backdraft(Option 1) TF 4'x 15'x 10' Volume=600ft 12"x 12"Square, 0"to 6" Vertical, Pointing
Area=60ft2 Centered at Downward
Side=15' Ceiling
Backdraft(Option 2) TF 4'x 9'x 18' Volume=648ft3 12"x 12" 0"to 6" Vertical, Pointing
x
Area=36ft2 Square, Downward
Side=9' Centered at.
Ceiling
Pantleg TF 4'x 15'x 12' Volume=720ft3 12"x 12"Square, 0"to 6" Vertical,Pointing
(Pantleg width Area=60ft2 Centered at Downward
dimensions: Side 15' Ceiling
1'minimum to
3'maximum)
Pit(Option 1) 3-Way 24'x 4'x 4' Volume=384ft3 Centered, Length, 0"to 6" Vertical,Pointing
Area=96ft2 Width,and Downward;Two
r Side=24' Height of Plenum Opposite Side
t Holes Parallel to
Longest Side
Pit(Option 2) D/P 24'x 4'x 4' Volume=384ft End, 0"to 6" Horizontal
Area=96ft2 Centered
Side=24'
s
Pit with Tunnel 3-Way Pit:24'x 4'x 4' Volume=576ft3 Centered, Yz Pit Vertical,Pointing
(Option 1) (Nozzle No Area=144ft2 Vertically; Height Downward;Each
Further Than 12' Side=24' Centered,Length Side Hole Aligned
From Either Pit of Pit;12" From Parallel with Pit
End.) Start of Tunnel and Tunnel
Tunnel: Sections
12'x4'x4'
Downdraft, Side 3-Way Plenum: Volume=640ft3 Centered, Length — Horizontal, Each
Exhaust With Vertical 24'x 4'x'4' Area=96ft2 of Plenum; Side Hole Aligned
Transition (Nozzle no Side 24' Centered, Parallel with
Further Than 12' Width of Plenum; Plenum and
From Either End Centered, Height Transition Sections
of Plenum.) of Plenum
Transition:
4'x 4'x 16'tall
Under Floor TF 14'x 15'x V Volume=210ft3 Side-Entry; 0"to 6" Horizontal
Area=210ftz Centered,
Side=15' Vertically;
<> Centered,
Lengthwise(t6")
*Nozzle Offset is the maximum distance from the tip of the nozzle to the nearest edge of the protected zone.
UL EX 5208 April 9,2013
P/N 15040 System Design Page 3A-35
3A.4.2.1 Standard Plenum Coverage,VPSB continued
I
/24'
PIT OPTION 2:
p;p 24
NOZZLE
i T
2,v j i I P7 OPTION
J— 3-WAY
NOZZLE
12 �4
T
4'
0
�4'
j /P �.
3-WAY NOZZLLE/
/ _2 '_ ` \�✓/IT
NOZZLE
y
t
24'
24' �\
i
N.
NGZZ-E 4'
12' ;
3'MAX.
/ I T7
4
NyC
ta' -� R E 24'
\ / NOZZLE
� I
j I L/4
/
\ \15'
4' i
28'
HAXIMUM '9
I O
MAXIMUM TF
NOZZLE
I ,L)
TF
NOZZLE '
i
5'
MAXIMUM
4,
UL EX 5208 April 9,2013
P/N 15040 System Design Page 3A-38
3A.4.3 Duct Coverage, VPSB
The D/P Nozzle will protect either round or rectangular ducts up to 28 feet in length. Any change in duct direction or
additional length requires an additional D/P nozzle. The duct nozzle must be centered at the duct entrance, pointed in
the direction of air flow. The tip of the duct nozzle must be within 6"of the duct entrance.
Round Ducts
Maximum Diameter, Single Nozzle=46 Inches Rectangular Ducts
Maximum Diameter,Two Nozzles =52 Inches The following table shows sample maximum rectangular
(nozzle spacing: .5 x duct diameter, located on the dimensions, based on the following two requirements:
same plane) Maximum Perimeter= 144.5 Inches
Maximum Diagonal =46 Inches
Spacing for two nozzles, protecting a duct
diameter larger than 46", up to 52" maximum Rectangular Ducts
Side 1,Inches Side 2, Inches,
Maximum
12 44.4
14 43.8
16 43.1
18 42.3
20 41.4
22 40.4
24 39.2
26 37.9
28 36.5
` 30 34.8
32 33.0
32.5 32.5
34 31.0
36 28.6
38 -25.9
40 22.7
42 18.7
44 13.4
UL EX 5208 April 9,2013
i
i
i
1
Date: 03/30/2026
Permit#: 3226
Permit 06/12/2020
Date:
Review 06/12/2020
Date:
Permit FIRE SPRINKLER
Type:
Review FIRE SPRINKLER
Type:
Target Date: 06/26/2020
Scheduled 00:00
Time:
Completed 06/16/2020
Date:
Description: 1. Permit and set of approved plans to remain on site during installation. 2. System shall be
connected to fire alarm system per IFC 904.3.5. 3.A dual action manual pull station that activates
the building fire alarm system shall be installed on the exterior of the spray booth. 4.A horn
strobe shall be installed on the exterior of the spray booth and shall operate upon activation of the
spray booth fire suppression system. 5. Operation of the spray booth fire suppression system shall
shut-off the exhaust fan. 6.A nozzle cap blow-off test or similar test shall be conducted and
witnessed by the Arlington Fire Department. 7. Installation certification form to be completed
and submitted prior to close out of permit.
Review
Status:
Assigned To: Mike Makela
Time In: 00:00
Time Out: 00:00
Hours: 1.5
Notes
06/29/2020 1. Permit and set of approved plans to remain on site during installation.
2. System shall be connected to fire alarm system per IFC 904.3.5.
3.A dual action manual pull station that activates the building fire alarm system shall be
installed on the exterior of the spray booth.
4.A horn strobe shall be installed on the exterior of the spray booth and shall operate upon
activation of the spray booth fire suppression system.
5. Operation of the spray booth fire suppression system shall shut-off the exhaust fan.
6.A nozzle cap blow-off test or similar test shall be conducted and witnessed by the Arlington
Fire Department.
7. Installation certification form to be completed and submitted prior to close out of permit.
Property Information
Parcel#: 31051500401200 City of Arlington
City of Arlington 18204 59th Drive NE
18935 59th Avenue NE Arlington,WA 98223
Zoning: Lot: Block:
Permit#: 3226
Permit Date: 06/12/20
Permit Type: FIRE SPRINKLER
Project Name: Top Secret Coatings
Applicant Name: Pye Barker Fire
Applicant Address: PO Box 265
Applicant, City, State, Zip: Burlington,WA 98233
Contact: Nisha Taylor
Phone: 360-755-5444
Email: taylorn@pyebarkerfire.com
Scope of Work: Fire suppression for paint booth
Valuation: 7900.00
Square Feet: 0
Number of Stories: 0
Construction Type:
Occupancy Group:
ID Code:
Permit Issued: 07/01/2020
Permit Expires: 12/09/2020
Form Permit Type:
Status: LASERFICHE
Assigned To:
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
31051500401200 18935 59th Avenue NE City of Arlington
Contractors
Contractor Primary Contact Phone Address Contractor Type License License#
Pye Barker Fire Nisha Taylor 360-755-5444 PO Box 265 CONSTRUCTION COA 604 541 987
CONTRACTOR
CONSTRUCTION Labor and
Pye Barker Fire Nisha Taylor 360-755-5444 PO Box 265 CONTRACTOR IndustriesPYEBAFS807DO
Plan Reviews
Date Review Type Description Assigned To Review Status
06/12/2020 FIRE SPRINKLER BUILDING
1.Permit and set of approved plans to remain on site
during installation.
2.System shall be connected to fire alarm system per IFC
904.3.5.
3.A dual action manual pull station that activates the
building fire alarm system shall be installed on the exterior
of the spray booth.
4.A horn strobe shall be installed on the exterior of the
06/12/2020 FIRE SPRINKLER spray booth and shall operate upon activation of the spray Mike Makela
booth fire suppression system.
5.Operation of the spray booth fire suppression system
shall shut-off the exhaust fan.
6.A nozzle cap blow-off test or similar test shall be
conducted and witnessed by the Arlington Fire
Department.
7.Installation certification form to be completed and
submitted prior to close out of permit.
06/12/2020 FIRE SPRINKLER PW-WAT-REV
Fees
Fee Description Notes Amount
Fire Sprinkler System Commercial NFPA 13/13R $375.00
Processing/Technology $25.00
Fire System Plan Review Table 4-1 $147.31
Total $547.31
Attached Letters
Date Letter Description
06/12/2020 Building Permit
Payments
Date Paid By Description Payment Type Accepted By Amount
07/01/2020 Pye Baker Fire&Safety 1009 Raelynn Jones $547.31
Outstanding Balance $0.00
Uploaded Files
Date File Name
10/04/2021 9820077-3226 IC 11.6.2020.pdf
10/04/2021 9820078-3226 IC 8.11.2020.pdf
06/12/2020 6813477-3226 Application.pdf
06/12/2020 6813476-3226 Plans and Specifications.pdf