Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18712 35TH AVE NE_BLD3557_2026
NOTICE 1f TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY 0 APPROVED PERMIT#: l 0 AM ❑ PM DATE: JOB ADDRESS: LOT#: PROJECT: TYPE OF INSPECTION: OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE Cl PLANNING O CIVIL p BUILDING CITY OF ARLINGTON ' c• i t • I , Permit#: 3557 Permit Date: 11/19/20 Project Name: Kinford Company/Applicant Name: CM Heating Inc Company/Applicant Address: 1415 Broadway City, State, Zip: Everett, WA 98201 Contact: Debbie Bauers Phone: 425-259-0550 Email: debbie@cmheating.com Permit Type: Residential Mechanical Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Type of Construction: VB Occupancy Type: R-3; Residential Scope of Work: Replace gas furnace MIC/Opportunity Zone: Permit Issued: Permit Expires: 05/18/2021 DNU: Status: IN PROCESS Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning KINFORD 120 SINGLE 00946600000500 18712 35TH AVE NE SHANNON FAMILY M/BARTRAM RESIDENCE DONNA M Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM Heating Inc Debbie Bauers 425-259-0550 1415 Broadway MECHANICAL Labor& CMHEAMH877DN CONTRACTOR Industries Fees Fee Description Notes Amount Inspection Fee $75.00 Forced Air Heat fee per Btu $0.00 Mechanical Base Permit Fee $25.00 Processing/Technology Fee $25.00 Total $125.00 Uploaded Files Date File Name 11/19/2020 7725546-3557 Applicatian.pdf 11/19/2020 7725545-3557 Cut Sheets.pdf RESIDENTIAL MECHANICAL • s PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:18712 35TH AVE NE, ARLINGTON, WA 98223 Project Description:REPLACE GAS FURNACE Owner: SHANNON KINFORD Address: 18712 35TH AVE NE City: ARLINGTON State.WA Zip Code: 98223 Phone: 425-530-9129 Email:skinford@yahoo.com Applicant: C.M. HEAl1NG INC Address: 1415 Broadway City: Everett StateYVA Zip Code: 98201 Phone: 4252590550 Email: debbie@cmheating.com CONTRACTOR INFORMATION Contractor Name:C.M. HEAl1NG INC Address: 1415 Broadway City: Everett State WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration: 05/03/2021 Phone:4252590550 Email:debbie@cmheating.com STAFF USE O L Received Permit #: % Accepted by: Date: NOV 1_8 2020 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES uw� Furnace (80+) Model #ADD2B060ACV326 AFUE80% O Heat Pump Model #_ AFUE HSPE CI AC Unit Model # SEER Freestanding Stove Fire Place Insert U Outdoor BBQ ❑ Gas Piping Li Solid-Fuel Appliance Li Other rGas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: A„ Date: 11/18/2020 Applicant Printed Name. Debbie Bauers I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 _1 7tlxPr! e4W ShW4d4vd HEATING & AIR CONDITIONING Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum 84 AUD2B060ACV32B ADD2B060ACV32B AUD2B080ACV32B ADD2B080ACV32B AUD2C080ACV42B ADD2C100ACV52B AUD2B100ACV32B ADD2D120ACV52B AUD2C100ACV52B AUD2D120ACV52B AUD2D140ACV52B Two-Stage Fan Assisted Combustion System AUD2-ACV ADD2-ACV U pflow/Horizontal Downflow/Horizontal 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 000000 . 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O O O 0 00000c= 0 0 0 0 0 0 ococoo I c000roo 0 0 0 0 0 0 cood000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 PUB. NO. 12-1286-08 Received NOV 18 2020 4*0f je4a4f s�rwdrd HEATING & AIR CONDITIONING General Features COMMUNICATING MODE INTEGRATED SYSTEM CONTROL Furnace is shipped ready to be connected Exclusively designed operational program in communicating mode using three wire provides total control of furnace limit sen- hook-up using ACONT900 comfort control. sors,blowers, gas valve,flame control ALTERNATE 24V MODE and includes self diagnostics for ease of Furnace is field configurable to 24V non- service. Also includes connection points communicating mode. for E.A.C./humidifier. COMFORT CONTROL AIR DELIVERY Acculink IITM Communicating furnace The variable speed, direct drive blower design,offers plug and play—walk away in- motor, has sufficient airflow for most heat- stallation.Assures the entire heating and air ing and cooling requirements,will switch conditioning system is set up in the proper from heating to cooling speeds on demand from room thermostat. The blower door modes to optimize the engineered perfor- safety switch will prevent or terminate mance of the matched system installed. furnace operation when the blower door is NATURAL GAS MODELS removed. Central Heating furnace designs are certi- STYLING fied by the American Gas Association for both natural and L.P.gas. Limit setting and Heavy gauge steel and"wrap-around" cabinet construction is used in the rating data were established and approved under standard rating conditions using cabinet with baked-on enamel finish for American National Standards Institute strength and beauty. The heat exchanger standards. section of the cabinet is completely lined with foil faced fiberglass insulation. This SAFE OPERATION results in quiet and efficient operation due The Integrated System Control has solid to the excellent acoustical and insulating state devices,which continuously monitor qualities of fiberglass. Built-in bottom pan for presence of flame,when the system is and alternate bottom, left or right side in the heating mode of operation. Dual so- return air connection provision. lenoid combination gas valve and regulator provide extra safety. FEATURES AND GENERAL OPERATION QUICK HEATING The Platinum 80 High Efficiency Gas Durable,cycle tested, heavy gauge alu- Furnaces employ a Hot Surface Ignition minized steel heat exchanger quickly system,which eliminates the waste of a transfers heat to provide warm conditioned constant burning pilot. The integrated sys- air to the structure. Low energy power tem control lights the main burners upon a vent blower,to increase efficiency and demand for heat from the room thermostat. provide a positive discharge of gas fumes Complete front service access. to the outside. a. Low energy power venter BURNERS b. Vent proving pressure switch. Multiport In-shot burners will give years of quiet and efficient service. All models can be converted to L.P.gas. 0 2016 American Standard Heating&Air Conditioning 2 PUB.NO.12-1286-08 A�w sAwdud HEATING & AIR CONDITIONING Contents Feature Summary 2 Features and Benefits 4 Standard Equipment Optional Equipment General Data 6 AU D2B060ACV32B AU D2B080ACV32B AU D2C080ACV42B AUD213100ACV3213 AUD2C100ACV52B AUD21D120ACV5213 AU D2D 140ACV52B ADD2B060ACV32B ADD2B080ACV32B ADD2C100ACV5213 ADD21D120ACV5213 Performance Data 9 Electric Data 20 Field Wiring Diagrams 24 Dimensions 29 PUB.NO.12-1286-08 3 A*sffe*4" S7itqd4vd HEATING & AIR CONDITIONING Features and Benefits PLATINUM 80 STANDARD EQUIPMENT •AccuLinkTm II Communication or 24 •Slide out blower assembly Volt control •Variable speed ECM blower motor • Factory default is communication with continuous Comfort-RTM mode • Silicon Nitride hot surface igniter with • Field configurable to 24 volt adaptive heat up non-communicating mode • Manual reset flame rollout switches • Communication mode maybe used • Power supply 115/1/60 with: • Upflow models are convertible to All communicating outdoor units Horizontal Left or Left airflow. 24V Single stage cooling only units • Downflow models are convertible to •24 Volt non-communication mode may Horizontal Right or Left airflow.* be used with: • 115 Volt EAC/Humidifier connections - 24V Single stage, two stage, or •2-stage modulating gas valve two speed outdoor units •Accessory hook-up capability • Plug and play installation in • Integrated solid state control with communication mode with self-diagnostics communicating Comfort Control • Improved AccuCleanTM connections •Three wire connections to •Attractive color accents Comfort Control when used with • Heavy gauge aluminized steel heat communicating Comfort Control exchanger (ACONT900AC43UA) • Multi-port In-shot burners •Two speed inducer motor • Insulated blower door •Stored fault code history in •Gasketed blower door microprocessor non-volatile memory •Complete front service access • Furnace certified to leak 2% or less • Left/right gas connection of nominal air conditioning CFM •Optional L.P conversion kit delivered when pressurized to .5" • Optional extended warranties water column with all inlets, outlets, and drains sealed. * Soo Installor's Guide for venting applications. 4 PUB.NO.12-1286-08 4mw?Ao S'Awd rd HEATING & AIR CONDITIONING Features and Benefits PLATINUM 80 OPTIONAL EQUIPMENT Comfort control, Electronic Programmable 4-Stage Heating/2-Stage Cooling0 ......................................... ACONT900AC43UA( ] Comfort Control,XL802, Programmable 7 Day,3-Ht,2-CI..............................................................................ACONT802AS32DA( ] Comfort Control, XL803, Programmable 7 Day,3-Ht,2-CI with dehumidification............................................ACONT803AS32DA[ J Harness kit for 24V non-communicating connection.... . . ..................................................................................... BAYACHP024'[ J Propane Conversion Kit...........................................................................................................................................BAYLPKT21 OB[ 1 Propane Conversion Kit(with Stainless Steel Burners)..........................................................................................BAYLPSS21OB( I Harness kit for 24V non-communicating connection..............................................................................................BAYACHP024A( j AccuCleanTM Communicating Furnace Hook up Kit(24 vac converted units only)..........................................BAYACCECOMM101[j 5"Expandable High Efficiency Media Filter(17-1/2"Wide Gas Furnace)...............................................................TFM175BOFRO( j 5"Expandable High Efficiency Media Filter(21"Wide Gas Furnace)......................................................................TFM210BOFRO[ ] 5"Expandable High Efficiency Media Filter(24-1/2"Wide Gas Furnace)...............................................................TFM245BOFRO[ J 5"Cartridge High Efficiency Media Filter(17-1/2"Wide Gas Furnace)...................................................................TFM175AOFR1 [ ] 5"Cartridge High Efficiency Media Filter(21"Wide Gas Furnace)..........................................................................TFM210AOFR1 [ ] 5"Cartridge High Efficiency Media Filter(24-1/2"Wide Gas Furnace)...................................................................TFM245AOFR1 [ J 1"Medium Efficiency Pleated Filter(17- 1/2"Wide Gas Furnace)..........................................................................TFP175AOFR1 [ ] 1"Medium Efficiency Pleated Filter(21"Wide Gas Furnace). .. .............................................................................TFP210AOFR1 [ j 1"Medium Efficiency Pleated Filter(24-1/2"Wide Gas Furnace)............................................................................TFP245AOFR1 [ J Coil Enclosure(17-1/2"Wide Cabinets..............................................................................................................BAYCLE17A1722A[ J Coil Enclosure(21"Wide Cabinets)...................................................................................................................BAYCLE21A2130A[ J Coil Enclosure(24-1/2"Wide Cabinets)............................................................................................................BAYCLE24A2430A[ ] Side Filter Rack......................................................................................................................................... ..... ..........BAYFLTR200[ ] HighAltitude Switch....................................................................................................................................................BAYHALT249[ J Masonry Chimney Vent Kit(Upflow models only)...................................................................................................BAYVENT800B[ ] FilterRack Kit O....................................................................................................................................................BAYRACK960A[ ] Cleanable Filter(145717.5"wide Upflow models)......................................................................................... ...........BAYFLTR317[ J Cleanable Filter(21"wide Upflow models).................................................................................................................BAYFLTR321 [ J Cleanable Filter(24.5"wide Upflow models)..............................................................................................................BAYFLTR324( J AccuCleanT11,Whole House Air Cleaner(Upflow 17-1/2"Wide Gas Furnace) ................................................AFD175CLFR000C I J AccuCleanTM,Whole House Air Cleaner(Upflow 21"Wide Gas Furnace) ......................................................AFD210CLFR000C► j AccuCleanTM,Whole House Air Cleaner(Upflow 24-1/2"Wide Gas Furnace) ................................................AFD245CLFR000C I I AccuCleanTM,Whole House Air Cleaner(Downflow 17-1/2"Wide Gas Furnace) ...........................................AFD17DCLFR000C I I AccuCleanTM,Whole House Air Cleaner(Downflow 21"Wide Gas Furnace) ... .............................................AFD21 DCLFROOOC I I AccuCleanTM,Whole House Air Cleaner(Downflow 24-1/2"Wide Gas Furnace) ...........................................AFD24DCLFR000C I I AccuCleanTM,Whole House Transformer Kit(120 to 24 Volt-all TFD Air Cleaners)..........................................BAYTRANS12024( I T ACONT900AC43UA must be used for communication. 0 Available for models with 1800 CFM or greater which require an additional side return. PUB.NO.12-1286-08 5 A Sird HEATING & AIR CONDITIONING General Data Product Specifications ° DE "UD2B060ACV32B "UD2B080ACV32B "UD2C080ACV42B TYPE Upflow/Horizontal Upflow/Horizontal Upflow/Horizontal RATINGS V 1st Stage Input BTUH 39,000 52,000 52,000 1st Stage Capacity BTUH(ICS) O 31,200 41,600 41,600 2nd Stage Input BTUH 60,000 80,000 80,000 2nd Stage Capacity BTUH(ICS) O 48,000 64,000 64,000 Temp.rise(Min.-Max.)°F. 30-60 30-60 30-60 BLOWER DRIVE a e T Direct Uirect Direct Diameter-Width(In.) 10 x 7 10 x 7 1000 10 No.Used 1 1 1 Speeds(No.) Variable Variable Variable CFM vs.in.w.g. See Airflow Table See Airflow Table See Airflow Table Motor HP 112 1/2 3/4 R.P.M. Variable Variable Variable Volts/Ph/Hz 115/1/60 115/1/60 11511/60 FLA 5.2 5.2 7.4 COMBUSTION FAN—Type Centrifugal Centrifugal Centrifugal Drive-No.Speeds Direct-2 Direct-2 Direct-2 Motor HP PSC[Shaded Pole]-RPM 1/100/[1/145]-2543/1727 1/100/[1/1451-2543/1727 11100/[1/145]-2543/1727 Volts/Ph/Hz 115/1/60 115/1/60 115/1/60 FLA 0.70/0.40/[0.23/0.20] 0.70/0.40/[0.23/0.20] 0.70/0.40/[0.23/0.20] FILTER—Furnished? Yes Yes Yes Type Recommended High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 1-17x25-1 in. 1-17x25-1 in. 1 -20x25-1 in. VENT—Size(In.) 4 Round 4 Round 4 Round HEAT EXCHAN ER Type-Fired Alum.Steel-Type 1 Alum.Steel-Type 1 Alum.Steel-Type 1 -Unfired Gauge(Fired) 20 20 20 ORIFICES—Main V Nat.Gas.Qty—Drill Size 3—45 4—45 4—45 L.P.Gas Oty.—Drill Size 3—56 4—56 4—56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE Type Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition BURNERS—Type Multi-port In-shot Multi-port In-shot Multi-port In-shot Number 3 4 4 POWERCONN.—V/Ph Hz a 115/1/60 115/1/60 115/1/60 Ampacity(In Amps) 7.8 7.8 10.7 Max.Overcurrent Protection(Amps) 15 15 15 PIPE CONN.SIZE(In.) 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD Crated(In.) 41-3/4 x 19-1/2 x 30-1/2 41-3/4 x 19-1/2 x 30-1/2 41-3/4 x 23 x 30-1/2 WEIGHT Shipping(Lbs.)/Net(Lbs.) 136/126 142/132 155/145 TO Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3. (D For U.S,applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications,above input ratings(BTUH)are up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. O Based on U.S.government standard tests. O The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. O Furnace ships in natural gas configuration.The LP conversion kit used with the 2 stage furnace is BAYLPSS210B or BAYLPKT210B. ©First stage output capacity is approximately equal to 65%of second stage capacity. OO Direct drive variable speed blower motor is an ECM constant airflow blower motor. 6 PUB.NO.12-1286-08 ,�1�ceryca� Swdard HEATING & AIR CONDITIONING General Data Product Specifications ° MODEL *UD2B100ACV32B *UD2C100ACV52B *UD2D120ACV52B *UD2D140ACV52B TYPE Upflow/Horizontal Uoflow/Horizontal Upflow/Horizontal Upflow/Horizontal RATINGS O 1st Stage Input BTUH 65,000 65,000 78,000 91000 1st Stage Capacity BTUH(ICS) O 52,000 52,000 62,400 72,800 2nd Stage Input BTUH 100,000 100,000 120,000 140,000 2nd Stage Capacity BTUH(ICS) O 80,000 79,000 97,000 111,000 Temp,rise(Min.-Max.)"F 40-70 35-65 35-65 40-70 BLOWER DRIVE( &D Direct Direct Direct Direct Diameter-Width(In.) 10 x 7 10 x 10 10 x 10 10 x 10 No.Used 1 1 1 1 Speeds(No.) Variable Variable Variable Variable CFM vs.in.w.g. See Airflow Table See Airflow Table See Airflow Table See Airflow Table Motor HP 1/2 1 1 1 R.P.M. Variable Variable Variable Variable Volts/Ph/Hz 115/1/60 115/1/60 115/1/60 115/1/60 FLA 5.2 9.9 9.9 9.9 _ COMBUSTION FAN—Type Centrifugal Centrifugal Centrifugal Centrifugal Drive-No.Speeds Direct-2 Direct-2 Direct-2 Direct-2 Motor HP PSC[Shaded Pole]-RPM 1/75/[1/1451-270811868 1/75/[1/1451-2708/1868 1/60/[1/851-3090/2225 1/60-3100/2350 Volts/Ph/Hz 115/1/60 11511/60 115/1/60 115/1/60 FLA 0.87/0.49/f0.22/0.201 0.87/0.49/f0.22/0.201 1.14/0.51/f0.2510.211 1.16/0.54 FILTER—Furnished? Yes Yes Yes Yes Type Recommended High Velocity High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 1-17x25-1in. 1•20x25-1 in 1-2425-1 in 1-2425-1 in. VENT—Size(In.) 4 Round 4 Round 4 Round 4 Round HEAT EXCHANGER Type-Fired Alum.Steel-Type 1 Alum.Steel-Type 1 Alum.Steel-Type 1 Alum.Steel-Type 1 -Unfired Gauge(Fired) 20 20 20 20 ORIFICES—Main Nat.Gas.Oty—Drill Size 5—45 5—45 6—45 7—45 L.P.Gas Oty.—Drill Size 5—56 5—56 6—56 7—56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE Type Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition Hot Surface lanition BURNERS—Type Multi-port In-shot Multi-port In-shot Multi-port In-shot Multi-port In-shot Number 5 5 6 7 POWERCONN.—V/Ph/Hz ® 115/1/60 115/1/60 115/1160 115/1/60 Ampacity(In Amps) 8.1 13.9 14.3 14.3 Max.Overcurrenl Protection(Amps) 15 15 15 15 PIPE CONN.SIZE(In.) ill 112 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD HxWxD Crated(In.) _ 41-3/4 x 19-1/2 x 30-1/2 41-3/4 x 23 x 30-1/2 41-3/4 x 26-1/2 x 30-1/2 41-3/4 x 26-1/2 x 30-1/2 WEIGHT Shipping(Lbs.)/Net(Lbs.) 148/138 175/165 193/183 197/187 OO Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3. OO For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications,above input ratings(BTUH)are up to 4,500 feet,derate 4%per 1.000 feet for elevations above 4,500 feet above sea level, O Based on U.S.government standard tests. O The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. O Furnace ships in natural gas configuration.The LP conversion kit used with the 2 stage furnace is BAYLPSS210B or BAYLPKT210B. ©First stage output capacity is approximately equal to 65%of second stage capacity. O Direct drive variable speed blower motor to an ECM constant airflow blower motor. PUB.NO.12-1286-08 7 ,tmwawi, ShWdard HEATING & AIR CONDITIONING General Data Product Specifications ° MODEL *DD2BO60ACV32B *DD2B080ACV32B *DD2C100ACV526 *DD2D120ACV52B TYPE Downflow/Horizontal Downflow/Horizontal Downflow/Horizontal Downflow/Horizontal RATINGS 1st Stage Input BTUH 39,000 52,000 65,000 78,000 1 st Stage Capacity BTUH(ICS) O 31,200 41,600 52,000 62,400 2nd Stage Input BTUH 60,000 80,000 100,000 120,000 2nd Stage Capacity BTUH(ICS) O 48,000 63,000 81,000 95,000 Temp.rise(Min.-Max.)°F 35-65 35-65 35-65 35-65 BLOWER DRIVE(DW Direct Direct Direct Direct Diameter-Width(In.) 10 x 7 10 x 7 11 x 10 11 x 10 No.Used 1 1 1 1 Speeds(No.) Variable Variable Variable Variable CFM vs,in.w.g. See Airflow Table See Airflow Table See Airflow Table See Airflow Table Motor HP 1/2 1/2 1 1 R.P.M. Variable Variable Variable Variable Volts/Ph/Hz 115/1/60 115/1/60 115/1/60 115/1/60 FLA 5.2 5.2 9.9 9.9 COMBUSTION FAN—Type Centrifugal Centrifugal Centrifugal Centrifugal Drive-No,Speeds Direct-2 Direct-2 Direct-2 Direct-2 Motor HP PSC[Shaded Pole]-RPM 1/100/[1/145]-2543/1727 11100/[1/145]-2543/1727 1/75/[1/145]-2708/1868 1/60/[1/85]-3090/2225 Volts/Ph/Hz 115/1/60 115/1/60 115/1/60 115/1/60 FLA 0.70/0.40/[0.23/0.20] 0.70/0.40/[0.23/0.20] 0.87/0.49 I[0.22/0.20] 1.14/0.51/]0.25/0.21] FILTER—Furnished? Yes Yes Yes Yes Type Recommended High Velocity High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 2-1420-1 in. 2-1420-1 in. 2-16x20-1 in. 2-16x20-1 in. VENT—Size(In.) 4 Round 4 Round 4 Round 4 Round HEAT EXCHANGER Type-Fired Alum.Steel-Type 1 Alum.Steel-Type 1 Alum.Steel-Type 1 Alum.Steel-Type 1 -Unfired Gauge(Fired) 20 20 20 20 ORIFICES—Main Nat.Gas.Qty—Drill Size 3—45 4—45 5—45 6—4b L P.Gas CIty,—Drill Size 3—56 4—56 5—56 6—56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE Type Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition BURNERS—Type Multi-port In-shot Multi-port In-shot Multi-port In-shot Multi-port In-shot Number 3 4 5 6 POWER CONN.—V/Ph/Hz ® 115/1/60 115/1/60 115/1/60 115/1/60 Ampacity(In Amps) 7.8 7.8 13.9 14.3 Max.Overcurrent Protection(Amps) 15 15 18 15 PIPE CONN.SIZE(In.) 1/2 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD HxWxD Crated(In.) 41-3/4 x 19-1/2 x 30-1/2 41-3/4 x 19-1/2 x 30-1/2 41-3/4 x 23 x 30-1/2 41-3/4 x 26-1/2 x 30-1/2 WEIGHT Shipping(Lbs.)/Net(Lbs.) 140/130 146/136 166/156 197/187 O Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3. O For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications,above input ratings(BTUH)are up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. O Based on U.S.government standard tests. ©The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. O Furnace ships in natural gas configuration.The LP conversion kit used with the 2 stage furnace is BAYLPSS210B or BAYLPKT210B. ©First stage output capacity is approximately equal to 65%of second stage capacity. OO Direct drive variable speed blower motor is an ECM constant aidlow blower motor. 8 PUB.NO.12-1286-08 Performance Data A*W " S7�wdard HEATING & AIR CONDITIONING *UD2B060ACV32B Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 523 551 551 547 541 533 TEMP RISE 55 52 52 53 53 WATTS 52 83 103 119 150 HEATING CFM 651 674 673 667 657 1ST 650 TEMP RISE 44 43 43 43 44 STAGE WATTS 76 110 129 145 184 CFM 694 714 714 707 696 689 TEMP RISE 41 40 40 41 41 WATTS 87 122 140 155 197 CFIVI 838 851 850 841 826 820 TEMP RISE 53 52 52 53 54 WATTS 135 171 187 197 243 HEATING CFM 1035 1039 1038 1024 1006 2ND 1000 TEMP RISE 43 43 43 43 44 STAGE WATTS 227 263 277 271 318 CFM 1101 1102 1101 1086 1066 1060 TEMP RISE 40 1 40 40 41 42 WATTS 265 1 300 313 301 346 'UD2B060ACV32B Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 371 433 442 439 429 WATTS 28 57 84 110 137 350 CFM 547 571 573 564 549 15 WATTS 40 68 96 125 152 400 CFM 633 647 643 633 618 WATTS 52 83 111 141 171 450 CFM 701 715 711 704 694 WATTS 64 97 128 160 193 290 CFM 546 573 574 567 554 WATTS 49 80 108 139 168 350 CFM 725 739 738 728 717 2.0 WATTS 70 104 137 166 201 400 CFM 832 842 837 829 817 WATTS 94 131 166 201 237 450 CFM 935 943 939 930 921 WATTS 122 163 202 239 278 290 CFM 697 716 712 704 693 WATTS 74 110 145 177 211 350 CFM 909 915 911 904 895 2.5 WATTS 116 155 193 230 266 400 CFM 1040 1042 1043 1038 1027 WATTS 160 204 247 291 332 450 CFM 1178 1176 1175 1169 1164 WATTS 220 270 318 365 413 290 CFM 849 860 859 850 836 WATTS 114 155 196 230 268 350 CFM 1099 1097 1097 1089 1082 3.0 WATTS 183 228 274 318 363 400 CFM 1253 1250 1250 1243 1238 WATTS 258 312 364 415 466 450 CFM 1406 1403 1405 1354 1281 WATTS 363 420 484 1 503 1 500 NOTES: 1. 'FIRST LETTER MAY BE"A"OR"T' 2- "'FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFMlTON IS FOR DRY CLIMATE SETTING 6- CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFQRTAB�Y H�M�I).IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. PUB.NO.12-1286-08 9 t S7jW4j4ud Performance Data HEATING & AIR CONDITIONING *UD213080ACV32B Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 804 833 849 863 873 780 TEMP RISE 48 46 45 44 44 WATTS 66 110 190 229 278 HEATING CFM 930 950 958 960 958 1ST 897 TEMP RISE 41 40 40 40 40 STAGE WATTS 102 153 250 283 328 CFM 993 1009 1012 1008 1001 955.5 TEMP RISE 39 38 38 38 38 WATTS 124 176 279 308 350 CFM 1258 1255 1239 1210 1179 1200 TEMP RISE 47 1 47 48 49 50 WATTS 241 279 395 396 423 HEATING CFM 1453 1436 1407 1359 1310 2ND 1380 TEMP RISE 41 41 42 43 45 STAGE WATTS 354 362 475 446 457 CFM 1550 1526 1490 1433 1375 1470 TEMP RISE 38 1 39 40 41 43 WATTS 419 1 407 513 1 465 467 *UD213080ACV32B Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 709 736 734 727 716 WATTS 74 115 148 183 218 350 CFM 916 937 939 936 929 2 5 WATTS 109 154 193 233 272 400 CFM 1060 1071 1073 1072 1067 WATTS 156 204 250 295 340 450 CFM 1199 1208 1207 1209 1209 WATTS 216 269 322 374 428 290 CFM 878 891 897 886 875 WATTS 117 158 200 238 276 350 CFM 1110 1124 1125 1125 1121 3** WATTS 178 227 275 323 369 400** CFM 1277 1281 1282 1289 1291 WATTS 263 318 375 434 493 450 CFM 1445 1 1444 1445 1375 1300 WATTS 370 433 498 503 502 290 CFM 1040 1044 1049 1042 1034 WATTS 172 220 269 315 359 350 CFM 1303 1302 1300 1299 1296 3.5 WATTS 281 335 390 444 498 400 CFM 1 1485 1496 1453 1374 1298 WATTS 415 477 507 503 500 450 CFM 1603 1530 hi450 1369 1288 WATTS 1 514 510 505 501 498 NOTES: 1. "FIRST LETTER MAY BE"A"OR"T' 2. ""FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. 10 PUB.NO.12-1286-08 Performance Data AAW?AWSAwdaf-d HEATING & AIR CONDITIONING *UD2C080ACV42B Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 760 776 774 768 764 722 TEMP RISE 50 49 50 50 50 WATTS 86 126 191 188 231 HEATING CFM 844 859 858 851 846 1ST 819 TEMP RISE 45 45 45 45 45 STAGE WATTS 88 133 207 200 253 CFM 911 926 924 917 911 897 TEMP RISE 42 41 41 42 42 WATTS 93 142 224 211 273 CFM 1094 1108 1107 1099 1088 1110 TEMP RISE 54 53 53 54 54 WATTS 124 183 287 258 337 HEATING CFM 1222 1236 1236 1226 1213 2ND 1260 TEMP RISE 48 48 48 48 49 STAGE WATTS 160 224 347 302 389 CFM 1325 1338 1338 1329 1313 1380 TEMP RISE 45 44 44 44 45 WATTS 197 266 405 344 435 *UD2C080ACV42B Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 732 758 759 744 728 WATTS 61 100 137 171 207 350 CFM 893 905 905 892 874 2.5 WATTS 90 130 172 214 253 400 CFM 1014 1024 1019 1013 995 WATTS 117 163 206 251 294 450 CFM 1091 1107 1110 1104 1101 WATTS 137 188 237 284 337 290 CFM 888 900 897 889 876 WATTS 86 130 170 212 253 350 CFM 1069 1081 1081 1068 1063 3.0 WATTS 121 179 226 270 321 400 CFM 1202 1216 1211 1202 1190 WATTS 175 231 281 329 380 450 CFM 1307 1323 1328 1325 1322 WATTS 202 277 338 392 453 290 CFM 1034 1050 1043 1034 1024 WATTS 112 170 213 257 305 350 CFM 1190 1208 1212 1206 1203 3.5 WATTS 156 223 279 329 383 400 CFM 1363 1370 1378 1377 1370 WATTS 240 301 364 425 481 450 CFM 1565 1572 1575 1558 1516 WATTS 371 436 510 565 595 290 CFM 1150 1154 1147 1142 1132 WATTS 178 231 276 330 374 350 CFM 1363 1370 1378 1377 1370 4.0 WATTS 240 301 364 425 481 400 CFM 1594 1601 1603 1584 1536 WATTS 390 456 531 585 611 450 CFM 1824 1832 1829 1791 1703 WATTS 539 610 697 746 742 NOTES: 1. "FIRST LETTER MAY BE"A"OR"T' 2 "FACTORY SETTING 3 CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES- IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE PUB.NO.12-1286-08 11 A*WeJqS'hW4d4%rd Performance Data HEATING & AIR CONDITIONING "UD2B100ACV32B Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 842 848 841 828 812 839 TEMP RISE 57 57 57 58 59 WATTS 79 178 188 204 236 HEATING CFM 907 912 906 893 875 1ST 904 TEMP RISE 53 53 53 54 55 STAGE WATTS 97 207 217 231 262 CFM 973 976 971 958 939 969 TEMP RISE 49 49 49 50 51 WATTS 118 240 249 261 291 CFM 1298 1295 1293 1278 1253 1290 TEMP RISE 57 57 57 58 59 WATTS 258 451 456 452 459 HEATING CFM 1399 1394 1393 1370 1351 2ND 1390 TEMP RISE 53 53 53 54 55 STAGE WATTS 315 533 537 527 521 CFM 1500 1493 1493 1478 1448 1490 TEMP RISE 49 49 49 50 51 WATTS 378 623 627 608 588 "UD26100ACV32B Furnace Cooling Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 424 442 438 424 412 WATTS 25 53 78 102 127 350 CFM 514 533 526 512 493 1.5 WATTS 33 65 91 118 143 400 CFM 603 615 606 592 576 WATTS 44 79 107 135 164 450 CFM 686 691 676 667 652 WATTS 65 95 125 154 186 290 CFM 575 588 582 569 552 WATTS 40 75 101 130 158 350 CFM 712 716 703 691 677 2.0 WATTS 70 101 130 159 193 400 CFM 801 806 800 783 772 WATTS 84 127 160 192 227 450 CFM 908 910 905 895 879 WATTS 112 161 197 232 267 290 CFM 732 738 729 716 700 WATTS 67 107 136 168 200 350 CFM 884 884 880 867 851 2.5 WATTS 104 151 186 220 256 400 CFM 999 1004 1001 990 978 WATTS 146 199 239 279 318 450 CFM 1132 1134 1131 1123 1114 WATTS 204 262 310 354 399 290 CFM 878 882 875 859 844 WATTS 104 150 185 220 254 350 CFM 1055 1057 1054 1042 1036 3.0 WATTS 178 224 266 307 350 400 CFM 1205 1202 1200 1195 1190 WATTS 239 305 353 402 451 450 CFM 1351 1354 1351 1323 1253 WATTS 337 409 469 503 500 NOTES: 1. 'FIRST LETTER MAY BE"A"OR'T' 2. "FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFMITON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMt4,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. 12 PUB.NO.12-1286-08 Performance Data 4AW" S7�wdard HEATING & AIR CONDITIONING "UD2C100ACV52l3 Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 U. 0.9 CFM 738 806 847 881 908 845 TEMP RISE 65 59 57 54 53 WATTS 59 84 128 170 222 HEATING CFM 915 971 1003 1028 1046 1ST 1001 TEMP RISE 52 49 48 47 46 STAGE WATTS 70 129 197 250 315 CFM 996 1047 1074 1095 1109 1073 TEMP RISE 48 46 45 44 43 WATTS 84 155 232 288 357 CFM 1254 1288 1302 1310 1310 1300 TEMP RISE 59 57 57 56 56 WATTS 162 261 357 413 489 HEATING CFM 1526 1543 1543 1536 1523 2ND 1540 TEMP RISE 48 48 48 48 48 STAGE WATTS 303 411 512 553 623 CFM 1650 1659 1653 1640 1620 1650 TEMP RISE 45 1 44 45 45 46 WATTS 387 1 493 590 620 683 "UD2C100ACV52l3 Furnace Cooling Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 753 817 844 848 851 WATTS 69 115 161 206 253 350 CFM 972 1030 1057 1071 1067 3.0 WATTS 105 165 218 271 321 400 CFM 1140 1176 1193 1 1210 1214 WATTS 153 214 273 333 392 450 CFM 1284 1306 1314 1325 1337 WATTS 212 276 337 406 474 290 CFM 939 984 1009 1017 1015 WATTS 97 150 198 254 302 350 CFM 1141 1168 1181 1204 1203 3.5 WATTS 153 208 265 330 386 400 CFM 1415 1455 1473 1486 1500 WATTS 246 324 395 467 543 450 CFM 1543 1569 1567 1564 1574 WATTS 337 413 482 552 638 290 CFM 1083 1115 1129 1149 1147 WATTS 137 195 249 311 366 350 CFM 1415 1455 1473 1486 1500 4.0 WATTS 246 324 395 467 543 400 CFM 1619 1640 1650 1653 1654 WATTS 364 447 525 601 678 450 CFM 1855 1869 1874 1873 1867 WATTS 526 614 699 784 866 290 CFM 1390 1412 1417 1413 1426 WATTS 257 327 395 457 532 350 CFM 1740 1752 1755 1756 1749 5.0 WATTS 468 557 629 718 796 400 CFM 2095 2102 2086 2027 1941 WATTS 758 860 937 959 959 450 CFM 2277 2197 1 2112 2035 1950 NOTES: WATTS 972 973 1 963 970 969 1. "FIRST LETTER MAY BE"A"OR"T' 2. ""FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES- 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IFTHE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. PUB.NO.12-1286-08 13 At*w o S w4dmd Performance Data HEATING & AIR CONDITIONING *UD2131120ACV5213 Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 844 869 894 915 940 845 TEMP RISE 68 66 64 63 61 WATTS 87 132 146 185 220 HEATING CFM 1071 1090 1105 1116 1128 1 ST 1073 TEMP RISE 54 53 52 52 51 STAGE WATTS 126 186 227 296 345 CFM 1233 1248 1255 1259 1262 1235 TEMP RISE 47 46 46 46 46 WATTS 175 244 297 380 432 CFM 1298 1311 1316 1317 1316 1300 TEMP RISE 68 67 67 67 67 WATTS 200 272 327 415 467 HEATING CFM 1647 1651 1640 1626 1606 2ND 1650 TEMP RISE 54 54 54 54 55 STAGE WATTS 385 469 514 611 647 CFM 1897 1894 1872 1846 1812 1900 TEMP RISE 47 47 47 48 49 WATTS 1 569 657 674 762 1 770 *UD2D120ACV52l3 Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 1010 1036 1038 1039 1033 WATTS 118 168 216 266 315 350 CFM 1212 1228 1230 1228 1223 3.5 WATTS 167 237 291 345 403 400 CFM 1407 1420 1417 1416 1416 WATTS 240 318 380 441 508 450 CFM 1580 1584 1584 1581 1580 WATTS 342 415 484 553 624 290 CFM 1141 1159 1165 1164 1157 WATTS 157 211 263 316 373 350 CFM 1407 1420 1417 1416 1416 4.0 WATTS 240 318 380 441 508 400 CFM 1595 1609 1610 1604 1600 WATTS 356 428 500 571 639 450 CFM 1814 1817 1813 1801 1788 WATTS 505 582 655 729 803 290 CFM 1441 1417 1425 1421 1422 WATTS 267 322 386 447 512 350 CFM 1765 1773 1771 1768 1762 5.0 WATTS 457 550 627 705 780 400 CFM 2014 2011 2004 1992 1945 WATTS 662 768 849 932 974 450 CFM 2210 2193 2116 2038 1954 WATTS 902 1 990 989 1 984 979 NOTES: 1. "FIRST LETTER MAY BE"A"OR"T' 2. "FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUJMIQ,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. 14 PUB.NO.12-1286-08 Performance Data 4*W?AWS7iwdard HEATING & AIR CONDITIONING "UD2D140ACV52I3 Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 1012 1048 1068 1079 1095 1047 TEMP RISE 66 64 63 62 61 WATTS 99 162 211 269 372 HEATING CFM 1217 1240 1250 1251 1255 1ST 1248 TEMP RISE 55 54 54 54 53 STAGE WATTS 170 251 320 383 502 CFM 1290 1308 1314 1312 1311 1320 TEMP RISE 52 51 51 51 51 WATTS 203 288 360 423 546 CFM 1587 1584 1577 1560 1541 1610 TEMP RISE 65 65 65 66 67 WATTS 378 458 531 587 721 HEATING CFM 1903 1879 1857 1825 1787 2ND 1920 TEMP RISE 54 55 56 57 58 STAGE WATTS 637 682 729 763 895 CFM 2015 1984 1956 1919 1874 2030 TEMP RISE 51 52 53 54 55 WATTS 746 771 1 803 825 955 *UD2D140ACV52I3 Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 960 1001 1010 1009 1010 WATTS 106 167 218 268 320 350 CFM 1194 1205 1213 1207 1202 3.5 WATTS 187 243 297 356 420 400 CFM 1364 1376 1383 1381 1378 WATTS 249 327 392 454 525 450 CFM 1562 1553 1545 1555 1553 WATTS 373 434 530 573 636 290 CFM 1119 1144 1147 1144 1142 WATTS 148 218 271 328 388 350 CFM 1364 1376 1383 1381 1378 4.0 WATTS 249 327 392 454 525 400 CFM 1597 1593 1601 1586 1585 WATTS 378 459 534 598 672 450 CFM 1810 1812 1804 1796 1786 WATTS 560 638 714 790 868 290 CFM 1417 1427 1428 1417 1411 WATTS 275 359 421 481 546 350 CFM 1757 1754 1753 1739 1734 5.0 WATTS 511 592 666 731 812 400 CFM 1 2005 2001 1994 1956 1884 WATTS 751 844 930 975 982 450 CFM 2183 2106 2031 1957 1880LI WATTS 992 988 982 977 974 NOTES: 1. "FIRST LETTER MAY BE"A"OR"T' 2. '"FACTORY SETTING 3 CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6 CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFpRTABLY_HUMID,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. PUB.NO.12-1286-08 15 A*W shw4dzvd Performance Data HEATING & AIR CONDITIONING *DD2B060ACV32B Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 554 585 587 579 571 559 TEMP RISE 52 49 49 50 50 WATTS 50 73 85 124 171 HEATING CFM 622 652 655 648 637 1ST 624 TEMP RISE 46 44 44 44 45 STAGE WATTS 62 86 96 141 192 CFM 690 719 723 716 704 689 TEMP RISE 42 40 40 40 41 WATTS 78 102 110 160 216 CFM 869 896 902 896 879 860 TEMP RISE 51 49 49 49 50 WATTS 132 157 165 223 292 HEATING CFM 974 999 1006 1001 981 2ND 960 TEMP RISE 45 44 44 44 45 STAGE WATTS 173 198 210 269 345 CFM 1078 1102 1111 1107 1083 1060 TEMP RISE 41 40 40 40 41 WATTS 220 246 263 322 405 *DD26060ACV32B Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter UD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 422 465 473 462 449 WATTS 26 49 67 106 131 350 CFM 518 550 562 554 535 1.5 WATTS 34 60 75 122 149 400 CFM 606 631 633 631 612 WATTS 43 74 102 134 165 450 CFM 683 705 705 699 687 WATTS 59 88 99 163 190 290 CFM 583 609 614 610 591 WATTS 42 68 82 135 162 350 CFM 708 730 729 722 712 2.0 WATTS 57 91 122 155 190 400 CFM 805 837 830 823 817 WATTS 75 114 150 183 220 450 CFM 896 926 930 921 911 WATTS 98 142 182 220 256 290 CFM 732 757 754 747 738 WATTS 70 100 110 180 206 350 CFM 873 904 905 896 887 2.5 WATTS 112 146 152 245 265 400 CFM 1000 1030 1034 1029 1026 WATTS 126 176 222 264 308 450 CFM 1144 1169 1178 1174 1146 WATTS 213 253 252 392 394 290 CFM 883 909 918 913 893 WATTS 111 144 151 242 263 350 CFM 1056 1083 1091 1086 1083 3.0 WATTS 179 217 218 343 351 400 CFM 1223 1243 1260 1257 1252 WATTS 210 271 329 384 436 450 CFM 1404 1421 1442 1444 1362 NOTES: L WATTS 301 367 439 505 504 1. 'FIRST LETTER MAY BE"A"OR"T' 2. "FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNC2MFO81ABLY HUMID,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE 16 PUB.NO.12-1286-08 Performance Data AkW " S wda-d HEATING & AIR CONDITIONING *DD26080ACV32B Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 644 680 695 703 717 650 TEMP RISE 60 56 55 55 53 WATTS 66 91 108 129 167 HEATING CFM 723 754 766 770 778 1ST 728 TEMP RISE 53 51 50 50 49 STAGE WATTS 70 106 134 164 203 CFM 816 841 849 848 849 819 TEMP RISE 47 46 45 45 45 WATTS 82 127 167 205 244 CFM 1001 1013 1014 1005 990 1000 TEMP RISE 59 58 58 59 60 WATTS 131 186 237 284 319 HEATING CFM 1123 1128 1123 1108 1083 2ND 1120 TEMP RISE 53 52 53 53 54 STAGE WATTS 181 236 288 335 365 CFM 1266 1261 1250 1229 1192 1260 TEMP RISE 47 47 47 48 49 WATTS 256 306 351 394 413 *DD213080ACV3213 Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 723 742 738 726 715 WATTS 63 98 130 162 196 350 CFM 871 891 891 881 868 2.5 WATTS 94 138 176 210 247 400 CFM 1006 1019 1022 1013 1000 WATTS 134 182 224 265 307 450 CFM 1123 1131 1129 1120 1108 WATTS 182 235 282 326 367 290 CFM 868 891 884 877 866 WATTS 95 137 176 208 245 350 CFM 1055 1059 1063 1052 1045 3.0 WATTS 155 199 246 288 329 400 CFM 1193 1192 1202 1200 1193 WATTS 216 266 320 372 422 450 CFM 1355 1359 1359 1356 1300 WATTS 308 368 427 484 500 290 CFMI 1026 1039 1040 1029 1017 WATTS 142 188 232 272 311 350 CFM 1225 1231 1239 1235 1231 3.5 WATTS 224 281 336 386 437 400 CFM 1412 1408 1410 1397 1319 WATTS 333 390 462 509 504 F450 CFM 1596 1544 1469 1387 1315 WATTS 492 516 512 509 508 NOTES: 1. "FIRST LETTER MAY BE"A"OR"T' 2. -FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS 0_C0K FORTABLLY HIUMIQ,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. PUB.NO.12-1266-06 17 7j*I e4" S fyd�r Performance Data HEATING & AIR CONDITIONING 'DD2C100ACV52B Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 834 845 853 862 870 819 TEMP RISE 57 57 56 56 55 WATTS 71 138 155 178 225 HFATING CFM 904 913 919 925 930 1ST 891 TEMP RISE 53 52 52 52 52 STAGE WATTS 78 157 178 206 258 CFM 1012 1019 1021 1023 1023 1001 TEMP RISE 47 47 47 47 47 WATTS 95 192 216 250 310 CFM 1266 1268 1260 1252 1241 1260 TEMP RISE 58 58 59 59 59 WATTS 162 300 323 361 432 HEATING CFM 1374 1373 1361 1350 1333 2ND 1370 TEMP RISE 54 54 54 55 55 STAGE WATTS 202 357 375 411 485 CFM 1540 1536 1518 1500 1476 1540 TEMP RISE1 48 1 48 49 49 50 WATTS 1 278 1 459 464 492 567 "DDK100ACV5213 Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 888 890 887 879 866 WATTS 90 134 175 217 260 350 CFN1 1066 1065 1058 1052 1042 3.0 WATTS 137 184 229 277 325 400 CFM 1193 1196 1187 1182 1173 WATTS 183 236 287 338 393 450 CFM 1346 1349 1339 1334 1323 WATTS 240 297 353 409 465 290 CFM 1035 1042 1031 1025 1015 WATTS 123 172 217 264 311 350 CFM 1212 1210 1207 1197 1187 3.5 WATTS 190 242 294 346 399 400 CFM 1403 1404 1396 1384 1378 WATTS 256 319 378 432 492 450 CFM 1573 1578 1566 1555 1542 WATTS 358 427 486 550 612 290 CFM 1169 1166 1160 1153 1144 WATTS 170 219 269 320 371 350 CFM 1403 1404 1396 1384 1378 4.0 WATTS 256 319 378 432 492 400 CFM 1593 1597 1593 1583 1573 WATTS 369 439 505 573 636 450 CFM 1806 1805 1800 1795 1764 WATTS 511 586 662 735 787 290 CFM 1454 1448 1438 1434 1413 WATTS 292 351 409 469 522 350 CFM 1765 1778 1734 1726 1717 5.0 WATTS 488 575 612 685 760 400 CFM 2011 2006 1988 1951 1891 WATTS 697 779 848 900 920 450 CFM 2212 2159 2081 1998 1917 NOTES: WATTS 912 956 953 951 947 1. "FIRST LETTER MAY BE"A"OR"T 2. ""FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. 18 PUB.NO.12-1286-08 Performance Data 4AM?-AW S?`� yd&rd HEATING & AIR CONDITIONING *DD2D120ACV52B Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 1041 1045 1040 1010 1042 1040 TEMP RISE 55 55 55 57 55 WATTS 128 173 196 231 269 HEATING CFM 1178 1181 1176 1 1147 1170 1ST 1183 TEMP RISE 49 49 49 50 49 STAGE WATTS 169 218 241 284 334 CFM 1290 1292 1286 1259 1275 1300 TEMP RISE 45 45 45 46 45 WATTS 211 264 286 333 390 CFM 1578 1578 1570 1547 1543 1600 TEMP RISE 56 56 56 57 57 WATTS 352 414 433 482 543 HEATING CFM 1789 1788 1778 1757 1739 2ND 1820 TEMP RISE 49 49 50 50 51 STAGE WATTS 487 555 568 613 665 CFM 1962 1959 1 1949 1 1930 1900 2000 TEMP RISE 45 45 45 46 1 47 WATTS 618 690 1 697 734 1 771 *DD2D120ACV52B Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 1013 1020 1014 1004 993 WATTS 100 153 192 238 283 350 CFM 1216 1208 1210 1201 1187 3.5 WATTS 155 213 259 304 358 400 CFM 1380 1385 1377 1367 1362 WATTS 217 287 339 387 439 450 CFM M12 1561 1556 1544 1539 WATTS 377 434 490 550 290 CFM 1158 1148 1000 1131 WATTS 193 236 322 336 350CFM 1385 1377 1367 1362 4.0 WATTS 217 287 339 387 439 400 CFM 1579 1583 1580 1570 1559 WATTS 310 388 447 507 564 450 CFM 1788 1783 1759 1774 1769 WATTS 437 522 661 659 728 290 GFIVI 1430 1431 1424 1416 1406 WATTS 247 311 363 415 468 350 CFM 1730 1732 1728 1719 1714 5.0 WATTS 398 487 552 618 682 400 CFM 1980 1973 1967 1963 1966 WATTS 586 676 750 832 922 450 CFM 2175 2172 2157 2082 2009 WATTS 1 777 886 959 962 968 NOTES: 1- "FIRST LETTER MAY BE"A"OR'T' 2. "-FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFMlrON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING, 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFQRTABLY HUMID,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. PUB.NO.12-1286-08 19 y4�r��y S��-� Electrical Data HEATING & AIR CONDITIONING Wiring Diagram NAP RTp ANT, WH—C=—I LAME TABLE A INTEGRATED CONTROL IS POLARITY SENSITIVE, SENSORg HOT LEG OF 120V POWER SUPPLY MUST BE WH/5 �UD28r00ACV 32" CONNECTED TO THE BLACN POWER LEAD AS � -UD2BO60ACV32"" �UD2CIOOACVS2" INDICATED ON WIRING DIAGRAM, K15 I N$I -UD280BOACV32"" •UD2D120ACV52'^ •UD2CO80ACV42" •UD2D140ACV52" �o GR 6 : ■►RU IX MAY BE 'A'01 -1. 1 '" SUfFIN MAY 8E AA THROUGH TT GND I PRMARY .c�uo H� 1 Bx/l r _ L IMIT I�w FRS- FRS-2 SWITCH .haw r I ••WH YL/,I-Ea--k'j YL/R `�T YL/T r `L OR 6 , TL/3 PSI yBx/IIU �, s PS2 I EO--Q-(�-�i I= •I-WH/HUM L 2 STAGE 6R 3 INDUCER �BN/EAC 2 STAGE w AL 2 GAS VALVE t•�WHICAC L _SEE NOTE 4� `W==�� GR I 2 3 -_� JUNCTION BOX a m Y "s�'J-''�`-'o�`��` 3m3m;a;>. uo BURNER COMPARTMENT m _ WIRE BUNDLE , BLOWER COMPARTMENT ■ ■ ■ DOOR SEE— `�J ■ SWITCH NOTE T GND ■ rr YL/Bx REVERSE BMn�•D��BN1I 9x 8iI11 JUMPER LIMIT ■ SWITCH ■ ■ . O I 1 ■ 0 2 ICM 4 8L I NOMA f FAN 2 ■■ ■ O AIMM1 r .. BAIHDN 4 NH/ MOTOR I A ' NUN N/r 5 ex/8 eAl ' BM COM O T �8K?EAC g Mx Rn14 y 1 u15 ■ a ■ O e ■ ■ a O ■ ■ ' STATUS ' ■ FA& O ■ ■ 15-PIN CONNECTOR Y O ■ ;12OV II 4V I HLI HIGH LIMI IN UT ■ ■ 2 PSI PRESSURE SWITCH IST STAGE a ■ WHF4 _ 8L 3 RLI ROLLOUT LIMIT INPUT P •4K 4. TH 24VAC OR O O i , 5 TR 24V RETURN ■ 10 USER INTERFACE G RD U I4 Is YL/5 ° ° "' 1 N J T GPSOND PRESSURE SWITCH OUTPUT SEE NOTE 6 9 GND GROUND BLYL/4 u u u OR GR TO'PERSOMALITY MODULE 1 NO 31 10. HLO HIGH LIMIT OUTPUT YL/2 r ■ Q II MVC VALVE COMMON A 4 s (DI PS2 PRESSURE SWITCH 2ND STAGE OR BL 13 MVL GAS VALVE LOW STAGE YL 2 s YLII 14 MVH GAS VALVE HIGH STAGE 15 AXI REVERSE FLOW SWITCH INPUT ' 1 • Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. From Dwg D343534P01 (continued on next page) 20 PUB.NO.12-1266-08 Electrical Data A*�eb"� sold d HEATING & AIR CONDITIONING Schematic Diagram 115 VOLT 60 HZ I PH a G STI POWER SUPPLY PER LOCAL CODE - — - RED LEO - FAULT 0410 I flosA <rtry 20 stXonds �• ;H 'N +'` 2 FLASHES - SYSTEM LOCKOUT 6 FLASHES - III VOLT AC 1 1 -I ♦- �Y t 1 's RETRIES OR RECYCLES EXCEEDED POWER RE VERSED OA IGNITER FAULT IFC �GAA�GNO DOOR S .H �C4i11GND 3 FLASHES - PRESSURE SWITCH FAULT 7 FLASHES - GAS VALVE CIRCUIT ERROR -—-, 8 FLASHES - LOW FLAME SENSE SIGNAL r L1N[•x BAIL A FLASHES OPEN LIMIT SWITCH 9 FLASHES - OPEN INDUCER LIMIT IArMAN IBK/4 84/4 1 L 5 FLASHES - FLAME SENSED WHEN 10 FLASHES - COMMUNICATION FAULT IU ACx BA/ti 120N try NO FLAME SHOULD BE PRESENT CONTINUOUS ON - INTERNAL CONTROL FAILURE GREEN LED - STATUS VSINN I .. SLOW FLASH - NORMAL. NO CALL FOR HEAT FAST FLASH NORMAL. CALL FOR NEAT PRESENT L1NE-N nYl/BK GREEN ANO REO LEO'S ON CONTINUOUS INTERNAL CONTROL FAILURE CIRC-11 WH .: JUMF GREEN AND REO lFNR-N WH/ I I I LCM ) II[ IND"N WN t2 I FANS 2GN-N Nllex j wFAN I HWARNING CAUTIONEAC-NWIT 4 rr HAZARDOUS VOLTAGE USE COPPER CONDUCTORS ONLY! HUM-N I 418 5 DISCONNECT ALL ELECTRICAL POWER UNIT TERMINALS ARE NOT DESIGNED INCLUDING REMOTE DISCONNECTS TO ACCEPT OTHER TYPES OF CONDUCTORS. 6 BEFORE SERVICING FAILURE TO DO SO MAY CAUSE DAMAGE 12 v I e T FAILURE TO DISCONNECT POWER BEFORE TO THE EOUIPH NT. [ A. 2 NH 8 SERVICING CAN CAUSE SEVERE PERSONAL ONO j l 9 INJURY OR DEATH_ Tr q I 1 IGN-M I BK/S REPLACE WITH PART CNT 07081 OR EOUIVALENT TIMINGS ELECTRICAL RATING PREPURGE: 0 SEC.; INTEAPURGE: 60 SEC. INPUT: 25 V.A.C-, 60 HZ. POST PURGE: 5 SECONDS NUM•M 3 I XFMR SEC. CURRENT: 450 MA. I MV LOAD IGNITOR WARMUP: 20 SECONDS FLAME MV OUTPUT: 15 A 0 24 V.A C, TAP: 3; TFI: 5 SECOND$ SENSOR IND OUTPUT: 3 PHASE OUTPUT RETRIES: 2; RECYCLES: 10 EAC-N I ION OUTPUT: 2.0 A 0 12OV,A,C. HEAT ON DELAY: 45 SECONDS FS 2 1 N CIRC. BLOWER OUTPUT: 14.5 FLA, COOL ON DELAY: 0 SECONDS 25 LRA 0 120 VAC AUTO RESTART: 60 MINUTES HUMIDIFER A AIR CLEANER AUTO RESTART PURGE: 15 SECONDS LQ D j MAX. LOAD: 1-0 A 0 120 VAC 2 STAG HI BK 1 INDUCE 0-7 TCO THERMAL LINE CUT OUT FACTORY BN BLACK GA GREEN 24 V WIRING WH WHITE BA BROWN 0�0 PS PRESSURE . .LINE IL YELLOW RD RED SWITCH _ ifIELD .24 V JWIRING IOR ORANGE BL BLUE [ 1 FRS FLAME ROLLOUT TN T AO SWITCH rr INTERNAL THERMAL WIRE COLOR TR PROTECTION I GNO GL G� FP FLAME SENSOR B 11NUMBER ID (IF ANY) pS, CHASSIS GROUND CF P52 12 P51 P52 a CAPACITOR L LINE TH 24 VAC (HOT) HSI HOT SURFACE N NEUTRAL TR 24 VAC (COMMON) 1 ►53 REVERSE PRIMARY IGNITER 4 COIL G N D GROUND MV MAIN GAS VALVE PSo YLI LIMIT LIMIT b BIC COMMON TNS TRANSFORMER ST SW T o o DOOR SWITCH HLO HIGH LIMIT OUTPUT ILI INDUCER LIMIT INPUT x101O 1 YL/1 on,o FUSE HLI HIGH LIMIT INPUT IFC INTEGRATED FURNACE ILI 9 ' 4 ' ' TR RLI j YLII %2 FAST Yl l7 � LC LINE CHOKE [ AX115 1l/S IL1 I YL NOTE& Mul lj I. IF ANY OF THE ORIGNAL WIRING AS SUPPLIED WITH THIS FURNACE MUST BE REPLACED, 1 MVCII IT ,MUST BE WITHI WRE HAVING A TEMPERATURE RATING OF AT LEAST 105 C. MVH Id 2. USER INTERFACE MUST BE INSTALLED FOR PROPER FURNACE INSTALLATION & SET-UP, RD 1 3. CORRECT PERSONALITY MODULE IS RE0UTAED FOR PROPER FURNACE OPERATION. [ 1 8L 2 2 STAGE PERSONALITY MODULE IS SPECIFIC TO EACH MODEL & SERIAL NUMBER, AND IS TO REMAIN GAS VALVE WITHIN IT'S ORIGNAL UNIT. R j 4. THESE LEADS P I ROVDE 12OV POWER CONNECTIONS FOR ELECTRONIC AIR CLEANER (EAC) OS[A AND HUMIDIFIER (HUM). MAX. LOAD: 1.0 AMPS EACH. IAI(AFN[ 5. ON POWER-UP, LAST FOUR FAULTS, IF ANY, WILL BE FLASHED ON RED LED. ss GREEN LED WILL BE SOLID ON DURING LAST FAULT RECOVERY, 6. Y IS AN OUTPUT ONLY WHEN USED WITH A NON-COMMUNICATING, A/C ONLY, OUTDOOR UNIT, �Snsl•I� 7. LINE CHOKE ILC) NOT USED ON ALL MODELS. 8. IN 24 VOLT MODE, AN OPTIONAL HUMI DISTAT CAN BE CONNECTED BETWEEN THE "A" AND 1 "BK' TERMINALS. FACTORY INSTALLED 'BK JUMPER' ON THE CIRCUIT BOARD MUST BE CUT, bAsl-2 3 I SEE FURNACE INSTALLERS GUIDE FOR DETAILS. aQ•I I 1 ISAst-2 2 UD2 I 1 1 I R E V A From Dwg.D343534POl SEE NOTE 6 1 1 � Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. PUB.NO.12-1266-08 21 ;�Wff6aW e�S�ydud Electrical Data HEATING & AIR CONDITIONING Wiring Diagram I PIN CONN tEC BK aloweR SEE 9 1. HLJ HIGH LINT IN UT DOOR COMPARTMENT NOTE 7� SWITCH SAFETY 8 2 PSI PRESSURE SWITCH IST STAGE �� _ INTERLOCK T A. THI ROLLACOUT SWITCH INPUT Bail o eKn `•• _ LC 'A 11 6 5 TR 24V RETURN 8K/I 13K/1 J 5 BKlB 1 PSO PRESSURE SWITCH OUTPUT 4 WH/ INDOOR j BL 8 GND GROUND 3 FAN z g, o 10 HLO LIMIT SWITCH OUTPUT RD m 7 I MOTOR I II. MVC VALVE COMMON 12, PS2 PRESSURE SWITCH 2ND STAGE DR �Ar~ 0wNfa 13. MVL GAS VALVE LOW STAGE Y N/~ " PL/BK 14 MVH GAS VALVE HIGH STAGE a^ " GND JUMPER I5, ANI REVERSE FLOW SWITCH INPUT Gn/ W IHILAC wall OBM COM 0 = 0 DR �B�EACH '= J W _INS_ AD 3 IA Is YL/5 BKl4 RD YL/A e n n BR 120Y II�24V BLYL/2 Qi e OI GR ' IIHl4 BL RD OR BL I� W TO USER INTERFACE YL + Y YL/I U (SEE NOT ) STATUS r F/ LTO IM1 >• TO PERSONALITY MODULE T52 TSI (SEE NOTE 3) IM n o n q�an • o 0 (SEE NOTE 6) o e , •1 IT IT " t ~ REVERSE ••� A � SWI LIMIT "TIT, BLOWER WIRE BUNDLE TCO-C COMPARTMENT Tom � 1 I JUNCTION BON ,� FLAME BURNER WH COMPARTMENT r xm�3��rx '��SENSOR �o I GR tidW • � I HSI �a H• WHl �� N 2 2 STAGE I BK/'�i� INDUCFR 0 0 'OKI-I H/6 3 I� .. WH. . I i W OR 3 =.�WHrI• 6[ EWW FBA BL 2 2 STAGE GAS VALVE D ru20-7Yvc R I Ll A PSI PS2 IlN —BKIHUN it I= rWH/NUN I �Yu3 ` Rle v -�B nn KIEAC I rLls •u II IS a -rWH/EAC rL w fIAY[ FLAME PRIMARY -SEE NOTE 4 Aswi�il�i ROLL Sw I iCH Dui LIMIT SWITCH t TABLE 'A' MODELS L.._.._..J TDD2BO60ACV321A fDD2CI00ACV52-" INTEGRATED CONTROL IS POLARITY SENSITIVE. •DD28080ACV32"" •DD2D120ACV52"" HOT LEG OF12OV POWER SUPPLY MUST BE CONNECTED TO THE BLACK POWER LEAD AS INDICATED ON WIRING DIAGRAM. • PREFIA NAY BE 'A'OR'T' I --SBEFIl NAT BE AA THROUGH I1 A • Label all wires prior to disconnection when servicing controls. From Dwg.D343535POl Wiring errors can cause improper and dangerous operation. (continued on next page) Verify proper operation after servicing. 22 PUB.NO.12-1286-08 Electrical Data AwP�lw S*id d HEATING & AIR CONDITIONING Schematic Diagram 115 VOLT TO NJ. I PO POYER 51PII FER LQ(AIITS REO LED • FAULT Oolo • I Flolh ever t0 xelonds xN �Y[[[[ 2 FLASHES - SYSTEM LOCKOUT "OWE - 115 VOLT AC I I o RETRIES OR RECYCLES EXCEEDED POWER RE VE ASED OR IGN ITEA FAULT 0000 SYI TCH WN/Ifti1Gx0 3 FLASHES - PRESSURE SWITCH FAULT 7 FLASHES - GAS VALVE CIRCUIT ERROR `O a-BX/1�- B FLASHES - LOW FLAME SENSE SIGNAL ILINE-H BK/I 4 FLASHES OPEN LIMIT SWITCH 9 FLASHES - OPEN INDUCER LIMIT XFMR"H OKI BK/4 l 5 FLASHES - FLAME SENSED WHEN IO FLASHES - COMMUNICATION FAULT IC INC-N BK/I �•12DV 4V• NO FLAME SHOULD BE PRESENT CONTINUOUS ON - INTERNAL CONTROL FAILURE IVS I -H 1 NN/4D GREEN LED - STATUS ' SLOW FLASH - NORMAL. MO CALL TOR HEAT }� YL/6K FAST rLASN - NORMAL. CALL FOR HEAT PRESENT ILINE-0 I WN/I JUMPER GREEN AND RED LEDDS ON CONTINUOUS - INTERNAL CONTROL FAILURE ICING-N qH/t K/ 4 L GREEN AND RED LEDDS OFF CONTINUOUS - FUSE OPEN true-Y WWI I I ICM J ]No-Y -TV"/ 2 1NODDA L? N IAtII4 3 ,prop I K WARNNG CAUTI GM•N N/S EAC-N YNrt 4 HAZARDOUS VOLTAGE USE COPPER CONDUCTORS ONLY! 1 HUM-N 1 SKI 5 DISCONNECT ALL ELECTRICAL POWER UNIT TERMINALS ARE NOT DESIGNED B INCLUDING REMOTE DISCONNECTS TO ACCEPT OTHER TYPES OF CONDUCTORS. BEFORE SERVICING. 12 V 1 0 j FAILURE TO DO$0 MAY CAUSE DAMAGE I AA 2 1W FAILURE TO DISCONNECT POWER BEFORE TO THE EOUIPMENT- 8 SEflV ICING LAN CAUSE SEVERE PERSONAL GNO 3 , y INJURY OR DEATH Lzi 1 T• 4 1 N INTEGRATED FURNACE CONTROL IGoo-N I OKI$ REPLACE WITH PART CNT 07081 OR EQUIVALENT TIMINGS ELECTRICAL RATING PREPURGE: 0 SEC.; INTERPURGE: 60 SEC. xUMx 3 I INPUT: 25 V.A.0- 60 HZ POST PURGE: 5 SECONDS FLAME XFMR SEC. CURRENT: 450 MA. - NV LOAD IGNITOR WARMUP: 20 SECONDS SExSON MV OUTPUT: I.5 A 0 24 V.A.0 LAP: 3; TF I: 5 SECONDS E AC•x I IND OUTPUT: 3 PHASE OUTPUT RETRIES: 2: RECYCLES: 10 T 1 IGN OUTPUT: 2.0 A 0 120V.A.C. HEAT ON DELAY: 45 SECONDS FS 2 CIRC. BLOWER OUTPUT: 14.5 FLA, COOL ON DELAY: 0 SECONDS 25 LRA 0 120 VAC AUTO RESTART: 60 MINUTES HUMIDIFER & AIR CLEANER AUTO RESTART PURGE: 15 SECONDS LO 2 STAG MAX. LOAD: 1.0 A 0 120 VAC I I 3 HI ? IUCE TCO THERMAL LINE CUT OUT 1FACTORY ND BN BLACK GA GREEN 24 V WIRING 1 �p PS PRESSURE WH WHITE BA BROWN SWITCH ' •LINE l FIELD YL YELLOW AD RED _ _24 y WIRING IOR ORANGE BL BLUE I 1 FRS FLAKE ROLLOUT TH 1 no SWITCH AA INTERNAL THERMAL TN S PROTECTION �WIAE COLOR L BKII 1 Ox0 8 GA� [�� FP FLAKE SENSOR `NUMBER ID (IF ANY( PSI 2 REVERSE CHASSIS GROUND CIF CAPACITOR L INIT V L LINE TH 24 VAC (HOT) PSt 12 R P54.—.1 PS SWITCH N NEUTRAL TR 24 VAC (COMMON) fHSI HOT SURFACEPS 6 1PRIMARY IGNITER p GND GROUND MV MAIN GAS VALVE PTO jTL/t LIMIICOIL� b BZC COMMON TNT TRANSFORMER SWI1Cx o o DOOR SWITCH HLO HIGH LIMIT OUTPUT ILI INDUCER LIMIT INPUT IL01� I YL II .el I HLI HIGH LIMIT INPUT IFC INTEGRATED FURNACE 1 IL 9 I I o�,o FUSE CONTROL RLI 3 YL/I RSt tgT1 YL/7 l/l deb LC LINE CHOKE AZI I S Yl/T 1 NLI L13 YMV7EL�INVL �IF ANY OF THE ORIGINAL WIRING AS SUPPLIED WITH THIS FURNACE MUST BE REPLACED, MVC I IT MUST BE WITH WIRE HAVING A TEMPERATURE RATING OF AT LEAST 105 C. WN 2. USER INTERFACE MUST BE INSTALLED FOR PROPER FURNACE INSTALLATION & SET-UP. �iL_RO I 3. CORRECT PER SONAL ITY MODULE IS RE UIRED FOR PROPER FURNACE OPERATION. 2 STAGE PERSONALITY MODULE IS SPECIFIC TO EACH MODEL & SERIAL NUMBER, AND IS TO REMAIN 1 1 8L 2 WITHIN IT ORIGINAL UNIT. BB 3 GAS VALVE 4. THESE LEADS PROVIDE 120V POWER CONNECTIONS FOR ELECTRONIC AIR CLEANER (EAC) 015P14r AND HUMIDIFIER (HUM). MAX, LOAD: 1.0 AMPS EACH. ATTLYRL 5- ON POWER-UP, LAST FOUR FAULTS, IF ANY, WILL BE FLASHED ON RED LED. GREEN LED WILL BE SOLID ON DURING LAST FAULT RECOVERY. 6, YI IS AN OUTPUT ONLY WHEN USED WITH A NON-COMMUNICATING, A/C ONLY, OUTDOOR UNIT- Isnxl.I 1 7. LINE CHOKE (LC) NOT USED ON ALL MODELS. 8. IN 24 VOLT MODE, AN OPTIONAL HUMIDISTAT CAN BE CONNECTED BETWEEN THE "R- AND .6 TERMINALS. FACTORY INSTALLED "BK JUMPER' ON THE CIRCUIT BOARD MUST BE CUT. ISo,1.2 3 ( SEE FURNACE INSTAL LEAS GUIDE FOR DETAILS. 13ut-1 BI t 2 ISeAt• L— — — — 1 I DD2 I I I I From Dwg D343535POl REV A (SEE NOTE 71 ' A • Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. PUB.NO.12-1286.08 23 7**�e*w S71mdvd HEATING & AIR CONDITIONING Field Wiring Communicating Indoor Unit with Communicating Comfort Control and Communicating Outdoor Unit COMMUNICATING COMMUNICATING MODE COMMUNICATING COMFORT CONTROL INDOOR UNIT OUTDOOR UNIT BN TE 4 W3 ---NOTE 1 wz IFGFND wI ...... FACTORY WIRING Ga FIELD WIRING TERMINAL MAY E] OR MAY NOT BE PRESENT ON D D D UNIT NOTES: NOTE 5 I. SEE WIRING DIAGRAMS IN SERVICE FACTS FOR COMPLETE WIRING INFORMATION. R R 2 LOW VOLTAGE WIRING TO BE NO. IB AWG MINIMUM CONDUCTOR NOTE 6 3 BE SURE POWER SUPPLY AGREES WITH EOUIPMENT NAMEPLATE B B B POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. 4. IN COMMUNICATING MODE, UNUSED TERMINALS YI ARE NOT FUNCTIONAL. DO NOT USE. 5 "D" IS THE DATA LINE. INSTALLER TO SELECT A WIRE COLOR, Y2 6. TO CONNECT OPTIONAL DEVICES (SUCH AS A FLOAT SWITCH) WIRE IN SERIES FROM INDOOR 'R' TO COMFORT CONTROL "R'. 7 WHEN CONVERTING OUTDOOR UNIT TO 24 VAC MODE. USE 24 VAC HARNESS ACCESSORY IBAYACHP024-1 0 PRINTED FROM D802614POI REV01 24 PUB.NO.12-1266-08 Communicating Indoor Unit with Communicating Comfort Control and 24VAC Single Stage Cooling COMMUNICATING COMMUNICATING MODE 24 VAC OUTDOOR UNIT COMFORT CONTROL INDOOR UNIT I-STAGE AC ONLY • BR �3 alloii 4 EGEND .1 ...... FACTORY WIRING FIELD WIRING TERMINAL MAY OR MAY NOT BE PRESENT ON D B UNIT NOTES: NOTE I_ SEE WIRING DIAGRAMS IN SERVICE FACTS R R FOR COMPLETE WIRING INFORMATION. NOTE 6— 2 LOW VOLTAGE WIRING TO BE NO 18 AWG MINIMUM CONDUCTOR B B B 3 BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. POWER WIRING AND GROUNDING OF EOUIPMENT MUST COMPLY WITH LOCAL CODES. TI YI 4 IN COMMUNICATING MODE, UNUSED TERMINALS ARE NOT FUNCTIONAL DO NOT USE. 5 'D' IS THE DATA LINE INSTALLER TO SELECT A WIRE COLOR T? 6 TO CONNECT OPTIONAL DEVICES ISUCH AS A FLOAT SWITCH) WIRE IN SERIES FROM INDOOR "R" TO COMFORT CONTROL "R'. l.J PRINTED FROM D802614P02 REV01 0 24VAC Mode Indoor Unit with 24VAC Comfort Control and 24VAC Single Stage Cooling TYPICAL 24 VAC COMFORT CONTROL 24 VAC MODE 24 VAC OUTDOOR UNIT (SEE CONTROL INSTALLER'S GUIDE) INDOOR UNIT I-STAGE AC ONLY BK NOTE 4- W3 W3 -NOTE 5 W2 W2 ..... FACTORY WIRING WI WIox FIELD WIRING Q TE AMINAL MAY T OR NAY NOT G G BE PRESENT ON UNIT a NOTES. I. SEE WIRING DIAGRAMS IN SERVICE FACTS A A FOR COMPLETE WIRING INFORMATION. 2. LOW VOLTAGE WIRING TO BE NO. 18 AWG MINIMUM CONDUCTOR, 1 g B B 3, BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE, LJ POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES, YI YI YI 4. OPTIONAL FIELD WIRING. CONNECT ONLY IF THESE HEATING STAGES ARE USED. 5. CONNECTIONS TO 'R" "B M', AND "0" MUST BE MADE AS SHOWN Y2 Y2 'FACTO PROPER OPERATION WITH OPTIONAL HUMIDISTAT IN COOLING. FACTORY 'R' TO 'OK' JUMPER ON TERMINAL BLOCK MUST BE REMOVED ON AIR HANDLING UNITS. FACTORY °R" TO "B K. JUMPER ON FURNACE CONTROL MUST BE CUT ON NOTE 5- p FURNACES PRINTED FROM D80261/PC3 AE Y01 NOTE: To locate the BK to R jumper on the lFC board,see page 28. 24VAC Mode Indoor i_Jnit with 24VAC Comfort Control and 24VAC 2-Stage or 2-Step Cooling TYPICAL 24 VAC COMLOHI C'ONIROL 24 VAC MODL 24 VAC OUIDOON UNII (SEE CONTROL INSTALLER'S GUIDE) INDOOR UNIT 2-STAGE OR 2-STEP AC • BN NOTE t W3 W3j -H0:[ 5 LEGEND W2 W2 ...... FACTORY WIRING FIELD WIRING WI WI r-UT OR MINA) MAY OR MAY NOT BE PRESENT ON UNIT G G NOTES: ❑ I, SEE WIRING DIAGRAMS IN SERVICE FACTS p FOR COMPLETE WIRING INFORMATION 2 LOW VOLTAGE WIRING TO BE NO. 18 AWG MINIMUM CONDUCTOR R R R 3. BE SURE POWER SUPPLY AGREES WITH EOUIPMENT NAMEPLATE POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES- B B B 4, OPTIONAL FIELD WIRING CONNECT ONLY IF THESE HEATING STAGES ARE USED 5. CONNECTIONS TO 'R' "BK", AND -0' MUST BE MADE AS SHOWN FOR PROPER OPERATION WITH OPTIONAL HUMIDIST AT IN COOLING. YI YI YI FACTORY 'R' TO 'BK' JUMPER ON TERMINAL BLOCK MUST BE REMOVED ON AIR HANDL UNITS FACTORY TINGO 'BN" JUMPER ON FURNACE CONTROL MUST BE CUT ON FURNACES. Y2 Y2 Y2 6. SEE USER INTERFACE 24 VAC MODE SETUP MENU FOR IST STAGE CFM OPTIONS 2-STAGE - 39-64I 2-STEP = 65-BOI NOTE ;- 0 (PAINTED FROM D80261tPOt R[V01 NOTE: To locate the BK to R jumper on the IFC board,seepage 28. 24VAC Mode Indoor Unit with 24VAC Comfort Control and 24VAC Single Stage Heat Pump TYPICAL 24 VAC COMFORT CONTROL 24 VAC MODE 24 VAC OUTDOOR UNIT (SEE CONTROL INSTALLER'S GUIDE) INDOOR UNIT I-STAGE HEATPUMP • BN NOTE 4- -'SOIL 5 W3 W3] LEGLNO W2 W2 ...... FACTORY WIRING FIELD WIRING WI WI K2 TERMINAL MAY OR T OR MAY NOT BE PRESENT ON UNIT G G NOTES: El I. SEE WIRING DIAGRAMS IN SE MA SERVICE FACTS FOR COMPLETE WIRING INFOATI ON. 2 LOW VOLTAGE WIRING TO BE NO. 18 AWG MINIMUM CONDUCTOR. A A A 3 BE SURE POWER SUPPLY AGREES WITH EOUIPMENT NAMEPLATE. POWER WIRING AND GROUNDING OF EOUI PMENT MUST COMPLY WITH LOCAL CODES. B B B 4, OPTIONAL FIELD WIRING. CONNECT ONLY IF THESE HEATING STAGES ARE USED. 5, CONNECTIONS TO -R. 'BN", AND '0" MUST BE MADE AS SHOWN YI YI FOR PROPER OP[RATION WITH OPTIONAL HUMIDISTAT IN COOLING. FACTORY "R" TO "BK" JUMPER ON TERMINAL BLOCK MUST BE REMOVED ON AIR HANDLING UNITS, FACTORY "R" TO "B K., JUMPER ON FURNACE CONTROL MUST BE CUT ON Y2 Y2 FURNACES- 5 ON FURNACE APPLICATIONS, COMFORT CONTROL MUST BE DUAL FUEL COMPATIBLE (SEE CONTROL INSTALLERS GUIDE) OR NUST USE TAYPLUS103 0 0 0 IPRINTEO FROM D8026141`05 R[V01 NOTE: To locate the BK to R jumper on the IFC board,see page 28. 24VAC Mode Indoor Unit with 24VAC Comfort Control and 24VAC 2-Stage or 2-Step Heat Pump TYPICAL 24 VAC COMFORT CONTROL 24 VAC MODE 24 VAC OUTDOOR UNIT (SEE CONTROL INSTALLER'S GUIDE) INDOOR UNIT 2-STAGE OR 2-STEP HP BK - BK NOTE 4- x0 f S IFr ND W3 13 FACTORY WIRING FIELD WIRING W2 W2 TERMINAL MAY OR MAY NOT BE PRESENT ON UNIT w1 w1 zz NOTES: G G I- SEE WIRING DIAGRAMS IN SERVICE FACTS FOR COMPLETE WIRING INFORMATION 2. LOW VOLTAGE WIRING TO BE NO. 18 AWG MINIMUM CONDUCTOR 3 BE SURE POWER SUPPLY AGREES WITH EOUIPMENT NAMEPLATE POWER WIRING AND GROUNDING OF EOUIPNENT MUST COMPLY WITH LOCAL CODES A R A 4 OPTIONAL FIELD WIRING CONNECT ONLY IF THESE HEATING STAGES ARE USED B B B 5 CONNECTIONS TO R. 'BK', AND -0. MUST BE MADE AS SHOWN FOR PROPER OPERATION WITH OPTIONAL HUMIDISTAT IN COOLING FACTORY 'R' TO 'BK' JUMPER ON TERMINAL BLOCK MUST BE REMOVED ON AIR HANDLING UNITS TI YI YI FACTORY 'R' TO 'BK' JUMPER ON FURNACE CONTROL MUST BE CUT ON FURNACES 6 ON FURNACE APPLICATIONS, CON FORT CONTROL MUST BE DUAL FUEL COMPATIBLE Y2 Y2 Y2 (SEE CONTROL INSTALLERS GUIDEI OR MUST USE TAYPLUS103 1 SEE USER INTERFACE 24 VAC MODE SETUP MENU FOR IST STAGE CFM OPTIONS 2-STAGE = 39.641 0 0 2-STEP - 65-801 0 PRINTED FROM D802614P06 REVOI NOTE: To locate the BK to R jumper on the IFC board,see page 28 Wiring Notes: **,ke*4w SAwdard HEATING & AIR CONDITIONING [_]o c- 000 0 _ o + o � 00 LJ CI o L-J O LJL� LJ L=1 EEI rJ �OLJI L 0 W2 M UK 0 DD R o,C Y� Y2 0 The factory installed jumper be- tween"R"and"BK"on the circuit board must be cut if an optional Humidistat is installed. HUMIDISTAT HOOKUP-24 V Mode ONLY If an optional humidictat for humidity control in cooling is used, the factory installed"BK Jumper"must be cut. The BK Jumper must also be cut if a multi-zone controller is connected or*CONT402 is installed and using the BK enabled feature. See the 24VAC field hookup wiring diagrams for more information. 28 PUB.NO.12-1286.08 :o __ zz moo- .n- o0 .W .i �tYia a-mom H � .41 Ow Y V CD O s s— z— _ ,,,, C to r Cl) LU mo O N o = c7 v � N i m vl u� Z i O D O` I W � �i c w = 1 0 —I M O d Z i — 2 Z 2� V) W Q'• N N Q �1 C wJw O N p U¢ _ = m — — •� — ao i i w �Z a_. _ coUw '? -- I o •00 mmm mm mm J 61 M M M � LO LO LO ? m w Q > > > > > > > J W _ LU •s 2 �_ �co (O OD _O co N � Q I N N 0'2 mmm V U 00 L 7 Z N —M o00 00 00 ~ O to N Q[[[[[[[[[[ [ [ 0 a 0 wV w F- a0 E O N Z m V 0 0 mw W u'� E ` M ao CC E ~ oo — m M I V7 W Q�• N 0 W ¢ N u' Q i 1 1_A............................ Tw w Z V oo ww LILM w_o 1 ror M as Iziw awl zIz iw cg �o J� Z O uoz ...•.,u utV H z=mou '_� V=m w aZ is ii :s is ii Hzo •ee ee e -eao - _ OI U Z 0 ��3 F W J a J LL4 4� 4� •�... �4 W Q H L N J r O CIAp� m J Z �0 d O� V r C? r �Z co 0 J ¢ N Z X w¢V O N a z x \ Q W a 0? Q - (D (D U S -O I aD Q Z o c z _ �. jl ire Z N x O Q7� D) 7 6 _Z x f c o LU 00 J Q ^ a0 _ •n N _ N Q L Z r N N N N co 0 z 7LU � N U o o mm C\jm cOj c v J v Cl) Cl) LO � N Q v J U U U U J N - p 00 0 0 `� (D OD O N LL mm N o fI[[[[[[[f[[ [ [ ' (If(ffll[I l f l f IIIyF W M � � 1 N� �2 w • 0~Z w v 0 a Q ¢moo Vz =7) azo Jz ma -z O NO tD 'SLh 2 ¢ C7 4*w?4w Shw and HEATING & AIR CONDITIONING PUB.NO.12-1286-08 31 C US t+arso Atmme4w SW J Intertek HEATING & AIR CONDITIONING American Standard 12/16 Heating&Air Conditioning 6200 Troup Highway Tyler,TX 75707 Since American Standard Heating&Air conditioning has a policy of continuous product improvement,it www.americanstandardair.com reserves the right to change design and specifications without notice. �_y Q. RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 18712 35TH AVE NE, ARLINGTON, WA 98223 Project Description:REPLACE GAS FURNACE Owner: SHANNON KINFORD Address: 18712 35TH AVE NE City: ARLINGTON State.WA Zip Code: 98223 Phone: 425-530-9129 Email:skinford@yahoo.com Applicant: C.M. HEATING INC Address. 1415 Broadway City. Everett StateYVA Zip Code: 98201 Phone. 4252590550 Email. debbie@cmheating.com CONTRACTOR INFORMATION Contractor Name:C.M. HEATING INC Address: 1415 Broadway City: Everett State WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration: 05/03/2021 Phone: 4252590550 Email:debbie@cmheating.com STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #ADD2B060ACV32B AFUE80% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances ��eG(CeJo�7G���PiY�� Applicant Signature: tl5a51c3bba4a9294ftlaeB�b41eb Date: 11/18/2020 Applicant Printed Name: Debbie Bauers I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 Amwew shWilddwd HEATING & AIR CONDITIONING Jpflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum 80 AUD2B060ACV32B ADD2B060ACV32B AUD2B080ACV32B ADD2B080ACV32B AUD2C080ACV42B ADD2C100ACV52B AUD2B100ACV32B ADD2D120ACV52B AUD2C100ACV52B AUD2D120ACV52B AUD2D140ACV52B Two-Stage Fan Assisted Combustion System AUD2-ACV ADD2-ACV Upf low/Horizontal Downf low/Horizontal 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00000o I 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 PUB. NO. 12-1286-08 A*&feao SAwdard HEATING & AIR CONDITIONING General Features COMMUNICATING MODE INTEGRATED SYSTEM CONTROL Furnace is shipped ready to be connected Exclusively designed operational program in communicating mode using three wire provides total control of furnace limit sen- hook-up using ACONT900 comfort control. sors, blowers, gas valve,flame control ALTERNATE 24V MODE and includes self diagnostics for ease of Furnace is field configurable to 24V non- service. Also includes connection points communicating mode. for E.A.C./humidifier. COMFORT CONTROL AIR DELIVERY Acculink IITM Communicating furnace The variable speed, direct drive blower design,offers plug and play—walk away in- motor, has sufficient airflow for most heat- stallation.Assures the entire heating and air ing and cooling requirements,will switch conditioning system is set up in the proper from heating to cooling speeds on demand from room thermostat. The blower door modes to optimize the engineered perfor- safety switch will prevent or terminate mance of the matched system installed. furnace operation when the blower door is NATURAL GAS MODELS removed. Central Heating furnace designs are certi- STYLING fied by the American Gas Association for both natural and L.P.gas. Limit setting and Heavy gauge steel and"wrap-around" cabinet construction is used in the rating data were established and approved under standard rating conditions using cabinet with baked-on enamel finish for American National Standards Institute strength and beauty. The heat exchanger standards. section of the cabinet is completely lined with foil faced fiberglass insulation. This SAFE OPERATION results in quiet and efficient operation due The Integrated System Control has solid to the excellent acoustical and insulating state devices, which continuously monitor qualities of fiberglass. Built-in bottom pan for presence of flame,when the system is and alternate bottom, left or right side in the heating mode of operation. Dual so- return air connection provision. lenoid combination gas valve and regulator provide extra safety. FEATURES AND GENERAL OPERATION QUICK HEATING The Platinum 80 High Efficiency Gas Durable,cycle tested, heavy gauge alu- Furnaces employ a Hot Surface Ignition minized steel heat exchanger quickly system,which eliminates the waste of a transfers heat to provide warm conditioned constant burning pilot. The integrated sys- air to the structure. Low energy power tem control lights the main burners upon a vent blower,to increase efficiency and demand for heat from the room thermostat. provide a positive discharge of gas fumes Complete front service access. to the outside. a. Low energy power venter BURNERS b. Vent proving pressure switch. Multiport In-shot burners will give years of quiet and efficient service. All models can be converted to L.P.gas. ©2016 American Standard Heating&Air Conditioning 2 PUB.NO.12-1286-08 Amafew S*vda-f-d HEATING & AIR CONDITIONING Contents Feature Summary 2 Features and Benefits 4 Standard Equipment Optional Equipment General Data 6 AUD213060ACV32B AUD213080ACV32B AUD2C080ACV42B AUD213100ACV32B AUD2C100ACV52B AUD2D120ACV52B AUD2D140ACV52B ADD2B060ACV32B ADD2B080ACV32B ADMC100ACV5213 ADD21D120ACV5213 Performance Data 9 Electric Data 20 Field Wiring Diagrams 24 Dimensions 29 PUB.NO.12-1286-08 3 Amof iwo SAwdsrd HEATING & AIR CONDITIONING Features and Benefits PLATINUM 80 STANDARD EQUIPMENT • AccuLinkTM II Communication or 24 • Slide out blower assembly Volt control •Variable speed ECM blower motor • Factory default is communication with continuous Comfort-RTM mode • Silicon Nitride hot surface igniter with • Field configurable to 24 volt adaptive heat up non-communicating mode • Manual reset flame rollout switches • Communication mode maybe used • Power supply 115/1/60 with: • Upflow models are convertible to All communicating outdoor units Horizontal Left or Left airflow. 24V Single stage cooling only units • Downflow models are convertible to • 24 Volt non-communication mode may Horizontal Right or Left airflow." be used with: • 115 Volt EAC/Humidifier connections - 24V Single stage, two stage, or • 2-stage modulating gas valve two speed outdoor units • Accessory hook-up capability • Plug and play installation in • Integrated solid state control with communication mode with self-diagnostics communicating Comfort Control • Improved AccuCleanTM connections •Three wire connections to • Attractive color accents Comfort Control when used with • Heavy gauge aluminized steel heat communicating Comfort Control exchanger (ACONT900AC43UA) • Multi-port In-shot burners •Two speed inducer motor • Insulated blower door • Stored fault code history in • Gasketed blower door microprocessor non-volatile memory • Complete front service access • Furnace certified to leak 2% or less • Left/right gas connection of nominal air conditioning CFM • Optional L.P conversion kit delivered when pressurized to .5" • Optional extended warranties water column with all inlets, outlets, and drains sealed. * See Installer's Guide for venting applications. 4 PUB.NO.12-1286-08 Amafew S*vda-fid HEATING & AIR CONDITIONING Features and Benefits PLATINUM 80 OPTIONAL EQUIPMENT Comfort control, Electronic Programmable 4-Stage Heating/2-Stage CoolingO ......................................... ACONT900AC43UA[ ] Comfort Control, XL802, Programmable 7 Day, 3-Ht, 2-CI..............................................................................ACONT802AS32DA[ ] Comfort Control, XL803, Programmable 7 Day, 3-Ht, 2-CI with dehumidification............................................ACONT803AS32DA[ ] Harness kit for 24V non-communicating connection............................................................................................... BAYACHP024' [ ] Propane Conversion Kit...........................................................................................................................................BAYLPKT210B [ l Propane Conversion Kit (with Stainless Steel Burners) ..........................................................................................BAYLPSS210B [ ] Harness kit for 24V non-communicating connection.............................................................................................. BAYACHP024A[ ] AccuCleanTM Communicating Furnace Hook up Kit(24 vac converted units only)..........................................BAYACCECOMM101 [] 5"Expandable High Efficiency Media Filter(17-1/2"Wide Gas Furnace) ...............................................................TFM175BOFRO [ ] 5"Expandable High Efficiency Media Filter(21"Wide Gas Furnace)......................................................................TFM210BOFRO [ ] 5"Expandable High Efficiency Media Filter(24-1/2"Wide Gas Furnace) ...............................................................TFM245BOFRO [ ] 5"Cartridge High Efficiency Media Filter(17-1/2"Wide Gas Furnace)...................................................................TFM175AOFR1 [ ] 5"Cartridge High Efficiency Media Filter(21"Wide Gas Furnace)..........................................................................TFM210AOFR1 [ ] 5"Cartridge High Efficiency Media Filter(24-1/2"Wide Gas Furnace)...................................................................TFM245AOFR1 [ ] 1"Medium Efficiency Pleated Filter(17- 1/2"Wide Gas Furnace)..........................................................................TFP175AOFR1 [ ] 1"Medium Efficiency Pleated Filter(21"Wide Gas Furnace)..................................................................................TFP210AOFR1 [ ] 1"Medium Efficiency Pleated Filter(24-1/2"Wide Gas Furnace)............................................................................TFP245AOFR1 [ ] Coil Enclosure (17-1/2"Wide Cabinets..............................................................................................................BAYCLE17A1722A[ ] Coil Enclosure (21"Wide Cabinets)...................................................................................................................BAYCLE21A2130A[ l Coil Enclosure (24-1/2"Wide Cabinets) ............................................................................................................BAYCLE24A2430A[ ] SideFilter Rack..........................................................................................................................................................BAYFLTR200 [ l High Altitude Switch....................................................................................................................................................BAYHALT249 [ l Masonry Chimney Vent Kit (Upflow models only)................................................................................................... BAYVENT800B [ ] Filter Rack Kit® ....................................................................................................................................................BAYRACK960A[ l Cleanable Filter(145717.5"wide Upflow models).....................................................................................................BAYFLTR317[ ] Cleanable Filter(21"wide Upflow models).................................................................................................................BAYFLTR321 [ ] Cleanable Filter(24.5"wide Upflow models)..............................................................................................................BAYFLTR324[ ] AccuClean TM,Whole House Air Cleaner(Upflow 17-1/2"Wide Gas Furnace) ................................................AFD175CLFR000C [ ] AccuCleanTM,Whole House Air Cleaner(Upflow 21"Wide Gas Furnace) ......................................................AFD210CLFR000C [ AccuClean TM,Whole House Air Cleaner(Upflow 24-1/2"Wide Gas Furnace) ................................................AFD245CLFR000C [ J AccuCleanTM,Whole House Air Cleaner(Downflow 17-1/2"Wide Gas Furnace) ...........................................AFD17DCLFR000C [ ] AccuClean TM,Whole House Air Cleaner(Downflow 21"Wide Gas Furnace) .................................................AFD21 DCLFROOOC [ J AccuClean TM,Whole House Air Cleaner(Downflow 24-1/2"Wide Gas Furnace) ...........................................AFD24DCLFR000C [ AccuCleanTM,Whole House Transformer Kit(120 to 24 Volt-all TFD Air Cleaners)..........................................BAYTRANS12024 1 I O ACONT900AC43UA must be used for communication. O Available for models with 1800 CFM or greater which require an additional side return. PUB.NO.12-1286-08 5 AmafeAw S7imd4rd HEATING & AIR CONDITIONING General Data Product Specifications ° MODEL *UD2B060ACV32B *UD2B080ACV32B *UD2C080ACV42B TYPE Upflow/Horizontal Upflow/Horizontal Upflow/Horizontal RATINGS z 1 st Stage Input BTUH 39,000 52,000 52,000 1st Stage Capacity BTUH(ICS) ® 31,200 41,600 41,600 2nd Stage Input BTUH 60,000 80,000 80,000 2nd Stage Capacity BTUH(ICS) ® 48,000 64,000 64,000 Temp.rise(Min.-Max.)°F. 30-60 30-60 30-60 BLOWER DRIVE 3 5 7 Direct Direct Direct Diameter-Width(In.) 10 x 7 10 x 7 10 x 10 No.Used 1 1 1 Speeds(No.) Variable Variable Variable CFM vs.in.w.g. See Airflow Table See Airflow Table See Airflow Table Motor HP 1/2 1/2 3/4 R.P.M. Variable Variable Variable Volts/Ph/Hz 115/1/60 115/1/60 115/1/60 FLA 5.2 5.2 7.4 COMBUSTION FAN—Type Centrifugal Centrifugal Centrifugal Drive-No.Speeds Direct-2 Direct-2 Direct-2 Motor HP PSC[Shaded Pole]-RPM 1/100/[1/145]-2543/1727 1/100/[1/145]-2543/1727 1/100/[1/145]-2543/1727 Volts/Ph/Hz 115/1/60 115/1/60 115/1/60 FLA 0.70/0.40/[0.23/0.20] 0.70/0.40/[0.23/0.20] 0.70/0.40/[0.23/0.20] FILTER—Furnished? Yes Yes Yes Type Recommended High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 1-17x25-1 in. 1-17x25-1 in. 1-20x25-1 in. VENT—Size(In.) 4 Round 4 Round 4 Round HEAT EXCHANGER Type-Fired Alum.Steel-Type 1 Alum.Steel-Type 1 Alum.Steel-Type 1 -Unfired Gauge(Fired) 20 20 20 ORIFICES—Main U5 Nat.Gas.Qty.—Drill Size 3—45 4—45 4—45 L.P.Gas Qty.—Drill Size 3—56 4—56 4—56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE Type Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition BURNERS—Type Multi-port In-shot Multi-port In-shot Multi-port In-shot Number 3 4 4 POWER CONN.—V/Ph/Hz a 115/1/60 115/1/60 115/1/60 Ampacity(In Amps) 7.8 7.8 10.7 Max.Overcurrent Protection(Amps) 15 15 15 PIPE CONN.SIZE(In.) 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD Crated(In.) 41-3/4 x 19-1/2 x 30-1/2 41-3/4 x 19-1/2 x 30-1/2 41-3/4 x 23 x 30-1/2 WEIGHT Shipping(Lbs.)/Net(Lbs.) 136/126 142/132 155/145 O Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3. O For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications,above input ratings(BTUH)are up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. O Based on U.S.government standard tests. ©The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. ©Furnace ships in natural gas configuration.The LP conversion kit used with the 2 stage furnace is BAYLPSS210B or BAYLPKT210B. ©First stage output capacity is approximately equal to 65%of second stage capacity. CO Direct drive variable speed blower motor is an ECM constant airflow blower motor. 6 PUB.NO.12-1286-08 Amafew S*vda-fid HEATING & AIR CONDITIONING General Data Product Specifications (J MODEL *UD2B100ACV32B *UD2C100ACV52B *UD2D120ACV52B *UD2D140ACV52B TYPE Upflow/Horizontal Upflow/Horizontal Upflow/Horizontal Upflow/Horizontal RATINGS ( 1st Stage Input BTUH 65,000 65,000 78,000 91000 1st Stage Capacity BTUH(ICS) ® 52,000 52,000 62,400 72,800 2nd Stage Input BTUH 100,000 100,000 120,000 140,000 2nd Stage Capacity BTUH(ICS) ® 80,000 79,000 97,000 111,000 Temp.rise(Min.-Max.)°F. 40-70 35-65 35-65 40-70 BLOWER DRIVE O©O Direct Direct Direct Direct Diameter-Width(In.) 10 x 7 10 x 10 10 x 10 10 x 10 No.Used 1 1 1 1 Speeds(No.) Variable Variable Variable Variable CFM vs.in.w.g. See Airflow Table See Airflow Table See Airflow Table See AirflowTable Motor HP 1/2 1 1 1 R.P.M. Variable Variable Variable Variable Volts/Ph/Hz 115/1/60 115/1/60 115/1/60 115/1/60 FLA 5.2 9.9 9.9 9.9 COMBUSTION FAN—Type Centrifugal Centrifugal Centrifugal Centrifugal Drive-No.Speeds Direct-2 Direct-2 Direct-2 Direct-2 Motor HP PSC[Shaded Pole]-RPM 1/75/[1/145]-2708/1868 1/75/[1/145]-2708/1868 1/60/[1/85]-3090/2225 1/60-3100/2350 Volts/Ph/Hz 115/1/60 115/1/60 115/1/60 115/1/60 FLA 0.87/0.49/[0.22/0.201 0.87/0.49/[0.22/0.201 1.14/0.51/[0.25/0.211 1.16/0.54 FILTER—Furnished? Yes Yes Yes Yes Type Recommended High Velocity High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 1 -17x25-1 in. 1-20x25-1 in. 1 -2425-1 in. 1-2425-1 in. VENT—Size(In.) 4 Round 4 Round 4 Round 4 Round HEAT EXCHANGER Type-Fired Alum.Steel-Type 1 Alum.Steel-Type 1 Alum.Steel-Type 1 Alum.Steel-Type 1 -Unfired Gauge(Fired) 20 20 20 20 ORIFICES—Main Nat.Gas.Qty.—Drill Size 5—45 5—45 6—45 7—45 L.P.Gas Qty.—Drill Size 5—56 5—56 6—56 7—56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage Redundant-Two Staqe PILOT SAFETY DEVICE Type Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition BURNERS—Type Multi-port In-shot Multi-port In-shot Multi-port In-shot Multi-port In-shot Number 5 5 6 7 POWER CONN.—V/Ph/Hz ® 115/1/60 115/1/60 115/1/60 115/1/60 Ampacity(In Amps) 8.1 13.9 14.3 14.3 Max.Overcurrent Protection(Amps) 15 15 15 15 PIPE CONN.SIZE(In.) 1/2 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD HxWxD Crated(In.) 41-3/4 x 19-1/2 x 30-1/2 41-3/4 x 23 x 30-1/2 41-3/4 x 26-1/2 x 30-1/2 41-3/4 x 26-1/2 x 30-1/2 WEIGHT Shipping(Lbs.)/Net(Lbs.) 148/138 175/165 193/183 197/187 O Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3. O For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications,above input ratings(BTUH)are up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. O Based on U.S.government standard tests. O The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. © Furnace ships in natural gas configuration.The LP conversion kit used with the 2 stage furnace is BAYLPSS210B or BAYLPKT210B. © First stage output capacity is approximately equal to 65%of second stage capacity. O Direct drive variable speed blower motor is an ECM constant airflow blower motor. PUB.NO.12-1286-08 7 AmafeAw S7imd4rd HEATING & AIR CONDITIONING General Data Product Specifications ° MODEL *DD2B060ACV32B *DD2B080ACV32B *DD2C100ACV52B *DD2D120ACV52B TYPE Downflow/Horizontal Downflow/Horizontal Downflow/Horizontal Downflow/Horizontal RATINGS 1 st Stage Input BTUH 39,000 52,000 65,000 78,000 1st Stage Capacity BTUH(ICS) ® 31,200 41,600 52,000 62,400 2nd Stage Input BTUH 60,000 80,000 100,000 120,000 2nd Stage Capacity BTUH(ICS) ® 48,000 63,000 81,000 95,000 Temp.rise(Min.-Max.)°F. 35-65 35-65 35-65 35-65 BLOWER DRIVE®©O Direct Direct Direct Direct Diameter-Width(In.) 10 x 7 10 x 7 11 x 10 11 x 10 No.Used 1 1 1 1 Speeds(No.) Variable Variable Variable Variable CFM vs.in.w.g. See Airflow Table See Airflow Table See Airflow Table See Airflow Table Motor HP 1/2 1/2 1 1 R.P.M. Variable Variable Variable Variable Volts/Ph/Hz 115/1/60 115/1/60 115/1/60 115/1/60 FLA 5.2 5.2 9.9 9.9 COMBUSTION FAN—Type Centrifugal Centrifugal Centrifugal Centrifugal Drive-No.Speeds Direct-2 Direct-2 Direct-2 Direct-2 Motor HP PSC[Shaded Pole]-RPM 1/100/[1/145]-2543/1727 1/100/[1/145]-2543/1727 1/75/[1/145]-2708/1868 1/60/[1/85]-3090/2225 Volts/Ph/Hz 115/1/60 115/1/60 115/1/60 115/1/60 FLA 0.70/0.40/[0.23/0.20] 0.70/0.40/[0.23/0.20] 0.87/0.49/[0.22/0.20] 1.14/0.51/[0.25/0.21] FILTER—Furnished? Yes Yes Yes Yes Type Recommended High Velocity High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 2-14x20-1 in. 2-14x20-1 in. 2-16x20-1 in. 2-16x20-1 in. VENT—Size(In.) 4 Round 4 Round 4 Round 4 Round HEAT EXCHANGER Type-Fired Alum.Steel-Type 1 Alum.Steel-Type 1 Alum.Steel-Type 1 Alum.Steel-Type 1 -Unfired Gauge(Fired) 20 20 20 20 ORIFICES—Main Nat.Gas.Qty.—Drill Size 3—45 4—45 5—45 6—45 L.P.Gas Qty.—Drill Size 3—56 4—56 5—56 6—56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE Type Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition Hot Surface Ignition BURNERS—Type Multi-port In-shot Multi-port In-shot Multi-port In-shot Multi-port In-shot Number 3 4 5 6 POWER CONN.—V/Ph/Hz ® 115/1/60 115/1/60 115/1/60 115/1/60 Ampacity(In Amps) 7.8 7.8 13.9 14.3 Max.Overcurrent Protection(Amps) 15 15 18 15 PIPE CONN.SIZE(In.) 1/2 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD HxWxD Crated(In.) 41-3/4 x 19-1/2 x 30-1/2 41-3/4 x 19-1/2 x 30-1/2 41-3/4 x 23 x 30-1/2 41-3/4 x 26-1/2 x 30-1/2 WEIGHT Shipping(Lbs.)/Net(Lbs.) 140/130 146/136 166/156 197/187 O Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3. O For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications,above input ratings(BTUH)are up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. O Based on U.S.government standard tests. ©The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. ©Furnace ships in natural gas configuration.The LP conversion kit used with the 2 stage furnace is BAYLPSS210B or BAYLPKT210B. ©First stage output capacity is approximately equal to 65%of second stage capacity. OO Direct drive variable speed blower motor is an ECM constant airflow blower motor. 8 PUB.NO.12-1286-08 Performance Data 74kafew S*mdae HEATING & AIR CONDITIONING 'UD213060ACV3213 Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 523 551 551 547 541 533 TEMP RISE 55 52 52 53 53 WATTS 52 83 103 119 150 HEATING CFM 651 674 673 667 657 1ST 650 TEMP RISE 44 43 43 1 43 44 STAGE WATTS 76 110 129 145 184 CFM 694 714 714 707 696 689 TEMP RISE 41 40 40 41 41 WATTS 87 122 140 155 197 CFM 838 851 850 841 826 820 TEMP RISE 53 52 52 53 54 WATTS 135 171 187 197 243 HEATING CFM 1035 1039 1038 1024 1006 2ND 1000 TEMP RISE 43 43 43 43 44 STAGE WATTS 227 263 277 271 318 CFM 1101 1102 1101 1086 1066 1060 TEMP RISE 40 40 40 41 42 WATTS 1 265 300 313 301 346 'UD2B060ACV32B Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 371 433 442 439 429 WATTS 28 57 84 110 137 350 CFM 547 571 573 564 549 1.5 WATTS 40 68 96 125 152 400 CFM 633 647 643 633 618 WATTS 52 83 111 141 171 450 CFM 701 715 711 704 694 WATTS 64 97 128 160 193 290 CFM 546 573 574 567 554 WATTS 49 80 108 139 168 350 CFM 725 739 738 728 717 2.0 WATTS 70 104 137 166 201 400 CFM 832 842 837 829 817 WATTS 94 131 166 201 237 450 CFM 935 943 939 930 921 WATTS 122 163 202 239 278 290 CFM 697 716 712 704 693 WATTS 74 110 145 177 211 350 CFM 909 915 911 904 895 2.5 WATTS 116 155 193 230 266 400 CFM 1040 1042 1043 1038 1027 WATTS 160 204 247 291 332 450 CFM 1178 1176 1175 1169 1164 WATTS 220 270 318 365 413 290 CFM 849 860 859 850 836 WATTS 114 155 196 230 268 350 CFM 1099 1097 1097 1089 1082 3.0 WATTS 183 228 274 318 363 400 CFM 1253 1250 1250 1243 1238 WATTS 258 312 364 415 466 450 CFM 1406 1403 1405 1354 1281 WATTS 363 420 484 503 500 NOTES: 1. 'FIRST LETTER MAY BE"A"OR"T' 2. "FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID,IT IS RECOMMENDED THATTHE FAN ONLY BE USED IN THE AUTO MODE. PUB.NO.12-1286-08 9 Amof iwo SAwdzrd Performance Data HEATING & AIR CONDITIONING *UD2B080ACV32B Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 804 833 849 863 873 780 TEMP RISE 48 46 45 44 44 WATTS 66 110 190 229 278 HEATING CFM 930 1 950 958 960 958 1ST 897 TEMP RISE 41 40 40 40 40 STAGE WATTS 102 153 250 283 328 CFM 993 1009 1012 1008 1001 955.5 TEMP RISE 39 38 38 38 38 WATTS 124 176 279 308 350 CFM 1258 1 1255 1239 1210 1179 1200 TEMP RISE 47 47 48 49 50 WATTS 241 279 395 396 423 HEATING CFM 1453 1436 1407 1359 1310 2ND 1380 TEMP RISE 41 41 42 43 45 STAGE WATTS 354 362 475 446 457 CFM 1550 1526 1490 1433 1375 1470 TEMP RISE 38 39 40 41 43 WATTS 419 407 513 465 467 *UD2B080ACV32B Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 709 736 734 727 716 WATTS 74 115 148 183 218 350 CFM 916 937 939 936 929 2.5 WATTS 109 154 193 233 1 272 400 CFM 1060 1071 1073 1072 1067 WATTS 156 204 250 295 340 450 CFM 1199 1208 1207 1209 1209 WATTS 216 269 322 374 428 290 CFM 878 891 897 886 875 WATTS 117 158 200 238 276 350 CFM 1110 1124 1125 1125 1121 3** WATTS 178 227 275 323 369 400** CFM 1277 1281 1282 1289 1291 WATTS 263 318 375 434 493 450 CFM 1445 1444 1445 1375 1300 WATTS 370 433 498 503 502 290 CFM 1040 1044 1049 1042 1034 WATTS 172 220 269 315 359 350 CFM 1303 1302 1300 1299 1296 3.5 WATTS 281 335 390 444 498 400 CFM 1485 1496 1453 1374 1298 WATTS 415 477 507 503 500 450 CFM 1603 1530 1450 1369 1288 WATTS 514 510 505 501 498 NOTES: 1. 'FIRST LETTER MAY BE"A"OR"T' 2. -FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. 10 PUB.NO.12-1286-08 Performance Data 74!'cafe w! S*vdard HEATING & AIR CONDITIONING *UD2C080ACV42B Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 760 776 774 768 764 722 TEMP RISE 50 49 50 50 50 WATTS 86 126 191 188 231 HEATING CFM 844 859 858 851 846 1ST 819 TEMP RISE 45 45 45 45 45 STAGE WATTS 88 133 207 1 200 253 CFM 911 926 924 917 911 897 TEMP RISE 42 41 41 42 42 WATTS 93 142 224 211 273 CFM 1094 1108 1107 1099 1088 1110 TEMP RISE 54 53 53 54 54 WATTS 124 183 287 1 258 337 HEATING CFM 1222 1236 1236 1226 1213 2ND 21380 TEMP RISE 48 48 48 48 49 STAGWATTS 160 224 347 302 389 CFM 1325 1338 1338 1329 1313 TEMP RISE 45 44 44 44 45 WATTS 197 266 1 405 1 344 435 *UD2C080ACV42B Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 732 758 759 744 728 WATTS 61 100 137 171 207 350 CFM 893 905 905 892 874 2.5 WATTS 90 130 172 214 253 400 CFM 1014 1024 1019 1013 995 WATTS 117 163 206 1 251 294 450 CFM 1091 1107 1110 1104 1101 WATTS 137 188 237 284 337 290 CFM 888 900 897 889 876 WATTS 86 130 170 212 253 350 CFM 1069 1081 1081 1068 1063 3.0 WATTS 121 179 226 270 321 400 CFM 1202 1216 1211 1202 1190 WATTS 175 231 281 329 380 450 CFM 1307 1323 1328 1325 1322 WATTS 202 277 338 392 453 290 CFM 1034 1050 1 1043 1034 1024 WATTS 112 170 213 257 305 350 CFM 1190 1208 1212 1206 1203 3.5 WATTS 156 223 279 329 383 400 CFM 1363 1370 1378 1377 1370 WATTS 240 301 364 1 425 481 450 CFM 1565 1572 1575 1558 1516 WATTS 371 436 510 565 595 290 CFM 1150 1154 1147 1142 1132 WATTS 178 231 276 330 374 350 CFM 1363 1370 1378 1377 1370 4.0 WATTS 240 301 364 425 481 400 CFM 1594 1601 1603 1584 1536 WATTS 390 456 531 585 611 450 CFM 1824 1832 1829 1791 1703 WATTS 539 1 610 697 746 742 NOTES: 1. *FIRST LETTER MAY BE"A"OR°T' 2. —FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. PUB.NO.12-1286-08 11 Amof iwo SAwdzrd Performance Data HEATING & AIR CONDITIONING *UD213100ACV32B Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 842 848 841 828 812 839 TEMP RISE 57 57 57 58 59 WATTS 79 178 188 204 236 HEATING CFM 907 912 906 893 875 1ST 904 TEMP RISE 53 53 53 54 55 STAGE WATTS 97 207 217 231 262 CFM 973 976 971 958 939 969 TEMP RISE 49 49 49 50 51 WATTS 118 240 249 261 291 CFM 1298 1295 1293 1278 1253 1290 TEMP RISE 57 57 57 58 59 WATTS 258 451 456 452 459 HEATING CFM 1399 1394 1393 1378 1351 2ND 1390 TEMP RISE 53 53 53 54 55 STAGE WATTS 315 533 537 527 521 CFM 1500 1493 1493 1478 1448 1490 TEMP RISE 49 49 49 50 51 WATTS 378 623 627 608 588 *UD213100ACV326 Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 424 442 438 424 412 WATTS 25 53 78 102 127 350 CFM 514 533 526 512 493 1.5 WATTS 33 65 91 118 143 400 CFM 603 615 606 592 576 WATTS 44 79 107 135 164 450 CFM 686 691 676 667 652 WATTS 65 95 125 154 186 290 CFM 575 588 582 569 552 WATTS 40 75 101 130 158 350 CFM 712 716 703 691 677 2.0 WATTS 70 101 130 159 193 400 CFM 801 806 800 783 772 WATTS 84 127 160 192 227 450 CFM 908 910 905 895 879 WATTS 112 161 197 232 267 290 CFM 732 738 729 716 700 WATTS 67 107 136 168 200 350 CFM 884 884 880 867 851 2.5 WATTS 104 151 186 220 256 400 CFM 999 1004 1001 990 978 WATTS 146 199 239 279 318 450 CFM 1132 1134 1131 1123 1114 WATTS 204 262 310 354 399 290 CFM 878 882 875 859 844 WATTS 104 150 185 220 254 350 CFM 1055 1057 1054 1042 1036 3.0 WATTS 178 224 266 307 350 400 CFM 1205 1202 1200 1195 1190 WATTS 239 305 353 402 451 450 CFM 1351 1354 1351 1323 1253 NOTES: WATTS 337 409 469 503 500 1. 'FIRST LETTER MAY BE"A"OR"T' 2. —FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. 12 PUB.NO.12-1286-08 Performance Data 74kafew S*mdae HEATING & AIR CONDITIONING *UD2C100ACV52B Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 738 806 847 881 908 845 TEMP RISE 65 59 57 54 53 WATTS 59 84 128 170 222 HEATING CFM 915 971 1003 1028 1046 1ST 1001 TEMP RISE 52 49 48 47 46 STAGE WATTS 70 129 197 250 315 CFM 996 1047 1074 1095 1109 1073 TEMP RISE 48 46 45 44 43 WATTS 84 155 232 288 357 CFM 1254 1288 1302 1310 1310 1300 TEMP RISE 59 57 57 56 56 WATTS 162 261 357 413 489 HEATING CFM 1526 1543 1543 1536 1523 2ND 1540 TEMP RISE 48 48 48 48 48 STAGE WATTS 303 411 512 553 623 CFM 1650 1659 1653 1640 1620 1650 TEMP RISE 45 44 1 45 45 46 WATTS 387 493 1 590 620 683 "UD2C100ACV52B Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 753 817 844 848 851 WATTS 69 115 161 206 253 350 CFM 972 1030 1057 1071 1067 3.0 WATTS 105 165 218 271 321 400 CFM 1140 1176 1193 1210 1214 WATTS 153 214 273 333 392 450 CFM 1284 1306 1314 1325 1337 WATTS 212 276 337 406 474 290 CFM 939 984 1009 1017 1015 WATTS 97 150 198 254 302 350 CFM 1141 1168 1181 1204 1203 3.5 WATTS 153 208 265 330 386 400 CFM 1415 1455 1473 1486 1500 WATTS 246 324 395 467 543 450 CFM 1543 1569 1567 1564 1574 WATTS 337 413 482 552 638 290 CFM 1083 1115 1129 1149 1147 WATTS 137 195 249 311 366 350 CFM 1415 1455 1473 1486 1500 4.0 WATTS 246 324 395 467 543 400 CFM 1619 1640 1650 1653 1654 WATTS 364 447 525 601 678 450 CFM 1855 1869 1874 1873 1867 WATTS 526 614 699 784 866 290 CFM 1390 1412 1417 1413 1426 WATTS 257 327 395 457 532 350 CFM 1740 1752 1755 1756 1749 5.0 WATTS 468 557 629 718 796 400 CFM 2095 2102 2086 2027 1941 WATTS 758 860 937 959 959 450 CFM 2277 2197 2112 2035 1950 NOTES: WATTS 972 973 963 970 969 1. 'FIRST LETTER MAY BE"A"OR°T' 2. "FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID,IT IS RECOMMENDED THATTHE FAN ONLY BE USED IN THE AUTO MODE. PUB.NO.12-1286-08 i3 Amof iwo SAwdzrd Performance Data HEATING & AIR CONDITIONING *UD2D120ACV52B Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 844 869 894 915 940 845 TEMP RISE 68 66 64 63 61 WATTS 87 132 146 185 220 HEATING CFM 1071 1090 1105 1116 1128 1ST 1073 TEMP RISE 54 53 52 52 51 STAGE WATTS 126 186 227 296 345 CFM 1233 1248 1255 1259 1262 1235 TEMP RISE 47 46 46 46 46 WATTS 175 244 297 380 432 CFM 1298 1311 1316 1317 1316 1300 TEMP RISE 68 67 67 67 67 WATTS 200 272 327 415 467 HEATING CFM 1647 1651 1640 1626 1606 2ND 1650 TEMP RISE 54 54 54 54 55 STAGE WATTS 385 469 514 611 647 CFM 1897 1894 1872 1846 1812 1900 TEMP RISE 47 47 47 48 49 WATTS 569 657 674 762 770 *UD2D120ACV52B Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 1010 1036 1038 1039 1033 WATTS 118 168 216 266 315 350 CFM 1212 1228 1230 1228 1223 3.5 WATTS 167 237 291 345 403 400 CFM 1407 1420 1417 1416 1416 WATTS 240 318 380 441 508 450 CFM 1580 1584 1584 1581 1580 WATTS 342 415 484 553 624 290 CFM 1141 1159 1165 1164 1157 WATTS 157 211 263 316 373 350 CFM 1407 1420 1417 1416 1416 4.0 WATTS 240 318 380 441 508 400 CFM 1595 1609 1610 1604 1600 WATTS 356 428 500 571 639 450 CFM 1814 1817 1813 1801 1788 WATTS 505 582 655 729 803 290 CFM 1441 1417 1425 1421 1422 WATTS 267 322 386 447 512 350 CFM 1765 1773 1771 1768 1762 5.0 WATTS 457 550 627 705 780 400 CFM 2014 2011 2004 1992 1945 WATTS 662 768 849 932 974 450 CFM 2210 2193 2116 2038 1954 WATTS 902 990 989 984 979 NOTES: 1. 'FIRST LETTER MAY BE"A"OR"T' 2. -FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. 14 PUB.NO.12-1286-08 Performance Data 74kafew S*mdae HEATING & AIR CONDITIONING *UD2D140ACV52B Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 1012 1048 1068 1079 1095 1047 TEMP RISE 66 64 63 62 61 WATTS 99 162 211 269 372 HEATING CFM 1217 1240 1250 1251 1255 1ST 1248 TEMP RISE 55 54 54 54 53 STAGE WATTS 170 251 320 383 502 CFM 1290 1308 1314 1312 1311 1320 TEMP RISE 52 51 51 51 51 WATTS 203 288 360 423 546 CFM 1587 1584 1577 1560 1541 1610 TEMP RISE 65 65 65 66 67 WATTS 378 458 531 587 721 HEATING CFM 1903 1879 1857 1825 1787 2ND 1920 TEMP RISE 54 55 56 57 58 STAGE WATTS 637 682 729 763 895 CFM 2015 1984 1956 1919 1874 2030 TEMP RISE 51 52 53 54 55 WATTS 746 771 803 825 955 *UD2D140ACV52B Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 960 1001 1010 1009 1010 WATTS 106 167 218 268 320 350 CFM 1194 1205 1213 1207 1202 3.5 WATTS 187 243 297 356 420 400 CFM 1364 1376 1383 1381 1378 WATTS 249 327 392 454 525 450 CFM 1562 1553 1545 1555 1553 WATTS 373 434 530 573 636 290 CFM 1119 1144 1147 1144 1142 WATTS 148 218 271 328 388 350 CFM 1364 1376 1383 1381 1378 4.0 WATTS 249 327 392 454 525 400 CFM 1597 1593 1601 1586 1585 WATTS 378 459 534 598 672 450 CFM 1810 1812 1804 1796 1786 WATTS 560 638 714 790 868 290 CFM 1417 1427 1428 1417 1411 WATTS 275 359 421 481 546 350 CFM 1757 1754 1753 1739 1734 5.0 WATTS 511 592 666 731 812 400 CFM 2005 2001 1994 1956 1884 WATTS 751 844 930 975 982 450 CFM 2183 2106 2031 1957 1880 WATTS 992 988 982 977 974 NOTES: 1. 'FIRST LETTER MAY BE"A"OR"T' 2. "FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID,IT IS RECOMMENDED THATTHE FAN ONLY BE USED IN THE AUTO MODE. PUB.NO.12-1286-08 15 Amof iwo SAwdzrd Performance Data HEATING & AIR CONDITIONING *DD2B060ACV32B Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 554 585 587 579 571 559 TEMP RISE 52 49 49 50 50 WATTS 50 73 85 124 171 HEATING CFM 622 652 655 648 637 1ST 624 TEMP RISE 46 44 44 44 45 STAGE WATTS 62 86 96 141 192 CFM 690 719 723 716 704 689 TEMP RISE 42 40 40 40 41 WATTS 78 102 110 160 216 CFM 869 896 902 896 879 860 TEMP RISE 51 49 49 49 50 WATTS 132 157 165 223 292 HEATING CFM 974 999 1006 1001 981 2ND 960 TEMP RISE 45 44 44 44 45 STAGE WATTS 173 198 210 269 345 CFM 1078 1102 1111 1107 1083 1060 TEMP RISE 41 40 40 40 41 WATTS 220 246 263 322 405 *DD2B060ACV32B Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 422 465 473 462 449 WATTS 26 49 67 106 131 350 CFM 518 550 562 554 535 1.5 WATTS 34 60 75 122 149 400 CFM 606 631 633 631 612 WATTS 43 74 102 134 165 450 CFM 683 705 705 699 687 WATTS 59 88 99 163 190 290 CFM 583 609 614 610 591 WATTS 42 68 82 135 162 350 CFM 708 730 729 722 712 2.0 WATTS 57 91 122 155 190 400 CFM 805 837 830 823 817 WATTS 75 114 150 183 220 450 CFM 896 926 930 921 911 WATTS 98 142 182 220 256 290 CFM 732 757 754 747 738 WATTS 70 100 110 180 206 350 CFM 873 904 905 896 887 2.5 WATTS 112 146 152 245 265 400 CFM 1000 1030 1034 1029 1026 WATTS 126 176 222 264 308 450 CFM 1144 1169 1178 1174 1146 WATTS 213 253 252 392 394 290 CFM 883 909 918 913 893 WATTS 111 144 151 242 263 350 CFM 1056 1083 1091 1086 1083 3.0 WATTS 179 217 218 343 351 400 CFM 1223 1243 1260 1257 1252 WATTS 210 271 329 384 436 450 CFM 1404 1421 1442 1444 1362 NOTES: WATTS 301 367 439 505 504 1. 'FIRST LETTER MAY BE"A"OR"T 2. —FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. 16 PUB.NO.12-1286-08 Performance Data 74kafew S*mdae HEATING & AIR CONDITIONING *DD213080ACV3213 Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 644 680 695 703 717 650 TEMP RISE 60 56 55 55 53 WATTS 66 91 108 129 167 HEATING CFM 723 754 766 770 778 1ST 728 TEMP RISE 53 51 50 50 49 STAGE WATTS 70 106 134 164 203 CFM 816 841 849 848 849 819 TEMP RISE 47 46 45 45 45 WATTS 82 127 167 205 244 CFM 1001 1013 1014 1005 990 1000 TEMP RISE 59 58 58 59 60 WATTS 131 186 237 284 319 HEATING CFM 1123 1128 1123 1108 1083 2ND 1120 TEMP RISE 53 52 53 53 54 STAGE WATTS 181 236 288 335 365 CFM 1266 1261 1250 1229 1192 1260 TEMP RISE 47 47 47 48 49 WATTS 256 306 351 394 413 *DD2B080ACV32B Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 723 742 738 726 715 WATTS 63 98 130 162 196 350 CFM 871 891 891 881 868 2.5 WATTS 94 138 176 210 247 400 CFM 1006 1019 1022 1013 1000 WATTS 134 182 224 265 307 450 CFM 1123 1131 1129 1120 1108 WATTS 182 235 282 326 367 290 CFM 868 891 884 877 866 WATTS 95 137 176 208 245 350 CFM 1055 1059 1063 1052 1045 3.0 WATTS 155 199 246 288 329 400 CFM 1193 1192 1202 1200 1193 WATTS 216 266 320 372 422 450 CFM 1355 1359 1359 1356 1300 WATTS 308 368 427 484 500 290 CFM 1026 1039 1040 1029 1017 WATTS 142 188 232 272 311 350 CFM 1225 1231 1239 1235 1231 3.5 WATTS 224 281 336 386 437 400 CFM 1412 1408 1410 1397 1319 WATTS 333 390 462 509 504 450 CFM 1596 1544 1469 1387 1315 WATTS 492 516 512 509 508 NOTES: 1. 'FIRST LETTER MAY BE"A"OR°T' 2. "FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID,IT IS RECOMMENDED THATTHE FAN ONLY BE USED IN THE AUTO MODE. PUB.NO.12-1286-08 i7 Amof iwo SAwdzrd Performance Data HEATING & AIR CONDITIONING *DD2C100ACV52B Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 834 845 853 862 870 819 TEMP RISE 57 57 56 56 55 WATTS 71 138 155 178 225 HEATING CFM 904 913 919 925 930 1ST 891 TEMP RISE 53 52 52 52 52 STAGE WATTS 78 157 178 206 258 CFM 1012 1019 1021 1023 1023 1001 TEMP RISE 47 47 47 47 47 WATTS 95 192 216 250 310 CFM 1266 1268 1260 1252 1241 1260 TEMP RISE 58 58 59 59 59 WATTS 162 300 323 361 432 HEATING CFM 1374 1373 1361 1350 1333 2ND 1370 TEMP RISE 54 54 54 55 55 STAGE WATTS 202 357 375 411 485 CFM 1540 1536 1518 1500 1476 1540 TEMP RISE 48 48 49 49 50 WATTS 278 459 464 492 567 *DD2C100ACV52B Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 888 890 887 879 866 WATTS 90 134 175 217 260 350 CFM 1066 1065 1058 1052 1042 3.0 WATTS 137 184 229 277 325 400 CFM 1193 1196 1187 1182 1173 WATTS 183 236 287 338 393 450 CFM 1346 1349 1339 1334 1323 WATTS 240 297 353 409 465 290 CFM 1035 1042 1031 1025 1015 WATTS 123 172 217 264 311 350 CFM 1212 1210 1207 1197 1187 3.5 WATTS 190 242 294 346 399 400 CFM 1403 1404 1396 1384 1378 WATTS 256 319 378 432 492 450 CFM 1573 1578 1566 1555 1542 WATTS 358 427 486 550 612 290 CFM 1169 1166 1160 1153 1144 WATTS 170 219 269 320 371 350 CFM 1403 1404 1396 1384 1378 4.0 WATTS 256 319 378 432 492 400 CFM 1593 1597 1593 1583 1573 WATTS 369 439 505 573 636 450 CFM 1806 1805 1800 1795 1764 WATTS 511 586 662 735 787 290 CFM 1454 1448 1438 1434 1413 WATTS 292 351 409 469 522 350 CFM 1765 1778 1734 1726 1717 5.0 WATTS 488 575 612 685 760 400 CFM 2011 2006 1988 1951 1891 WATTS 697 779 848 900 920 450 CFM 2212 2159 2081 1998 1917 NOTES: WATTS 912 956 953 951 947 1. 'FIRST LETTER MAY BE"A"OR"T' 2. —FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID,IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. i8 PUB.NO.12-1286-08 Performance Data 74kafew S*mdae HEATING & AIR CONDITIONING *DD2D 1 20ACV52B Furnace Heating Airflow(CFM)and Power(Watts)vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 1041 1045 1040 1010 1042 1040 TEMP RISE 55 55 55 57 55 WATTS 128 173 196 231 269 HEATING CFM 1178 1181 1176 1147 1170 1ST 1183 TEMP RISE 49 49 49 50 49 STAGE WATTS 169 218 241 284 334 CFM 1290 1292 1286 1259 1275 1300 TEMP RISE 45 45 45 46 45 WATTS 211 264 286 333 390 CFM 1578 1578 1570 1547 1543 1600 TEMP RISE 56 56 56 57 57 WATTS 352 414 433 482 543 HEATING CFM 1789 1788 1778 1757 1739 2ND 1820 TEMP RISE 49 49 50 50 51 STAGE WATTS 487 555 568 613 665 CFM 1962 1959 1949 1930 1900 2000 TEMP RISEI 45 45 45 46 47 _j WATTS 1 618 690 697 734 1 771 *DD2D 1 20ACV52B Furnace Cooling Airflow(CFM)and Power(Watts)vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 290 CFM 1013 1020 1014 1004 993 WATTS 100 153 192 238 283 350 CFM 1216 1208 1210 1201 1187 3.5 WATTS 155 213 259 304 358 400 CFM 1380 1385 1377 1367 1362 WATTS 217 287 339 387 439 450 CFM 1557 1561 1556 1544 1539 WATTS 312 377 434 490 550 290 CFM 1155 1158 1148 1000 1131 WATTS 149 193 236 322 336 350 CFM 1380 1385 1377 1367 1362 4.0 WATTS 217 287 339 387 439 400 CFM 1579 1583 1580 1570 1559 WATTS 310 388 447 507 564 450 CFM 1788 1783 1759 1774 1769 WATTS 437 522 661 659 728 290 CFM 1430 1431 1424 1416 1406 WATTS 247 311 363 415 468 350 CFM 1730 1732 1728 1719 1714 5.0 WATTS 398 487 552 618 682 400 CFM 1980 1973 1967 1963 1966 WATTS 586 676 750 832 922 450 CFM 2175 2172 2157 2082 2009 WATTS 777 886 959 962 968 NOTES: 1. 'FIRST LETTER MAY BE"A"OR"T' 2. "FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION,THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30%OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60%RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID,IT IS RECOMMENDED THATTHE FAN ONLY BE USED IN THE AUTO MODE. PUB.NO.12-1286-08 i9 Amof iwo SAwdzrd Electrical Data HEATING & AIR CONDITIONING Wiring Diagram IMPORTANT: WH—C==—FLAME TABLE "A" INTEGRATED CONTROL IS POLARITY SENSITIVE. SENSOR MODaS HOT LEG OF I20V POWER SUPPLY MUST BE WH/5 •UD21 I OOACV32"" CONNECTED TO THE BLACK POWER LEAD AS BK/5 HSI •UD2BO60ACV32^' •UD2C OOACV32"" INDICATED ON WIRING DIAGRAM. •UD2B 080AC V32"" •U D2C 080ACV42"" •UD2D120ACV52"" �•' •UD2D140ACV524" �o GR • PREFIX MAY BE "A" OR 'T" / "" SUFFIX MAY BE AA THROUGH ZZ ==J GND PRIMARY o�< H• o LIMIT 3 J BK/I FRS-I FRS-2 r SWITCH ••WH• •; YL/4 YL/8 YL/1 ■ L r J L L J OR b���I���I YL/3 .�WH%I =I PSI � �BK/HUM BR PS2 = _- rWH/HUM L 2 STAGE INDUCER "�—BK/EAC BR 3 2 STAGE BL- - -WH/EAC ���� RD I GAS VALVE L • •SEE NOTE 4J ww=?�; GR 2 z 1 —4 JUNCTION BOX 3 m 3m3m3m3a'�rYmp�¢�p m BURNER COMPARTMENT m _ lWIRE BUNDLE I BLOWER COMPARTMENT M ■ ■ DOOR SEE— SWITCH NOTE 1 GND REVERSE ■ rr YL/BK ■ Brc/I�o�o�erc/I B'BN/T JUMPER SWINTICH ■ _RD C ■ 2 CM 4 BL ■ =Brc INDOOR 3 H O �o 3 FAN 2 wH BK/xuM — 4 WH/ 4 MOTOR 1 en ■ 5 BK/8 *' Brc/ WH HUM WH/1 LC BM COM o * 6 ew 7 �BPEACJ B1 g wH wH/4 9 WH/I N/5 ■ O ® ■ ■ E:1 ■ ■ O ■ STpATUS ■ ■ FAULT ; v ■ ■ ■...... O T® I*T* � ' BK/4 TNS_RD 15-PIN CONNECTOR O ■ , 2OV 24V I. HLI HIGH LIMIT INPUT w wi rc e i rir ■ ■ 2. PSI PRESSURE SWITCH IST STAGE 1 ❑ ■ WH/4 _ 8L 3. RLI ROLLOUT LIMIT INPUT DRaCn ■ 4. TH 24VAC BR Oi P Po 5. TR 24V RETURN ■ +•• TO USER INTERFACE 6, o a i ri ■ (SEE NOTE 2) 1, PSO PRESSURE SWITCH OUTPUT RD 3 1a is YL/5 ■ 8. GND GROUND SEE NOTE 6 +•• TO PERSONALITY MODULE 9. BLYL/4 0 11 1t BR GR (SEE NOTE 3) 10. HLO HIGH LIMIT OUTPUT YL/2 e O II. MVC VALVE COMMON RD s (D 12. PS2 PRESSURE SWITCH 2ND STAGE OR BL 3. MVL GAS VALVE LOW STAGE YL 2 3 YL/I 14. MVH GAS VALVE HIGH STAGE 15. AXI REVERSE FLOW SWITCH INPUT Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. From Dwg.D343534P01 (continued on next page) 20 PUB.NO.12-1286-08 Electrical Data Akftf6" S*vdard HEATING & AIR CONDITIONING Schematic Diagram 115 VOLT 60 HZ. I PH DIAGNOSTIC CODES POWER SUPPLY PER LOCAL CODE RED LED - FAULT Dula - I Flash every 20 seconds - - ;H-f- �N - - 2 FLASHES - SYSTEM LOCKOUT 6 FLASHES - IIS VOLT AC RETRIES OR RECYCLES EXCEEDED POWER REVERSED OR IGNITER FAULT �GRf;1GND DOOR S ITCx 7 �1 Rf�9GND 3 FLASHES - PRESSURE SWITCH FAULT 7 FLASHES - GAS VALVE CIRCUIT ERROR IFC �,. 8 FLASHES - LOW FLAME SENSE SIGNAL r,NE-x ,Bxll� 4 FLASHES - OPEN LIMIT SWITCH 9 FLASHES - OPEN INDUCER LIMIT 1 5 FLASHES - FLAME SENSED WHEN 10 FLASHES - COMMUNICATION FAULT %FNR-H BK/4 BN/4 BL NO FLAME SHOULD BE PRESENT CONTINUOUS ON - INTERNAL CONTROL FAILURE ICIRC-H BK/7 120V 24V' WH/4 RD GREEN LED - STATUS IVSIM-H I .. SLOW FLASH - NORMAL, NO CALL FOR HEAT LC FAST FLASH - NORMAL, CALL FOR HEAT PRESENT LINE-N WH/I YL/3K GREEN AND RED LEDDS ON CONTINUOUS - INTERNAL CONTROL FAILURE CIRCA WH/1 L . .. JUMPER GREEN AND RED LEDDS OFF CONTINUOUS - FUSE OPEN %FMR-N WHId K/8" I 4 BL CM IND-N I WH/6 2 1 FA INDOOR 2 WH GN-N wH/s R/BK 3 Mo;oR I BK WARNING CAUTION ,AC-H H/7 q HAZARDOUS VOLTAGE USE COPPER CONDUCTORS ONLY! I HUM-N I BK/a 5 DISCONNECT ALL ELECTRICAL POWER UNIT TERMINALS ARE NOT DESIGNED INCLUDING REMOTE DISCONNECTS TO ACCEPT OTHER TYPES OF CONDUCTORS. 6 BEFORE SERVICING. 12 V BK 7 FAILURE TO DO SO MAY CAUSE DAMAGE Rs FAILURE TO DISCONNECT POWER BEFORE TO THE EQUIPMENT. 2 WH 8 SERVICING CAN CAUSE SEVERE PERSONAL GND 3 L 9 INJURY OR DEATH. I Ts q I H G INTEGRATED FURNACE CONTROL IGN-H BK/5 I _ REPLACE WITH PART CNT 07081 OR EQUIVALENT TIMINGS x 1 ELECTRICAL RATING PREPURGE: 0 SEC.; INTERPURGE: 60 SEC. INPUT: 25 V.A.C., 60 HZ. POST PURGE: 5 SECONDS HUM-H 3 I %FMR SEC. CURRENT: 450 MA. K MV LOAD IGNITOR WARMUP: 20 SECONDS FLAME MV OUTPUT: 1.5 A 0 24 V.A.C. AP: 3; TFI: 5 SECONDS SExSOR IND OUTPUT: 3 PHASE OUTPUT RETRIES: 2; RECYCLES: 10 EAC-H I IGN OUTPUT: 2.0 A 0 12OV.A.C. HEAT ON DELAY: 45 SECONDS FS 2 I H CIRC. BLOWER OUTPUT: 14.5 FLA. COOL ON DELAY: 0 SECONDS 25 LRA 0 120 VAC AUTO RESTART: 60 MINUTES HUMIDIFIER & AIR CLEANER AUTO RESTART PURGE: 15 SECONDS LO RD 3 MAX. LOAD: 1.0 A 0 120 VAC I EE(2 STAG2 TCO THERMAL BK INDUCE � CUT OUT LINE )FACTORY E BLACK GR GREEN 24 V )FACTORY WHITE �BR BROWN �a PS PRESSURE .LINE lFIELD YELLOW RD RED SWITCH _ _24 V f WIRING ORANGE BL BLUE FRS FLAME ROLLOUT TH 4 I RD SWITCH .. INTERNAL THERMAL WIRE COLOR S BL PROTECTION TR Q� FP FLAME SENSOR BK/ I GND $ GR ' q NUMBER ID (IF ANY) PSI 2 CHASSIS GROUND 1 CIF R a CAPACITOR L LINE TH 24 VAC (HOT) PS2 12 BR + P51 PS2 HSI HOT SURFACE IN NEUTRAL TR 24 VAC (COMMON) PS3 6 I .�-O P REVERSE PRIMARY IGNITER p GND GROUND MV MAIN GAS VALVE L/6 + LIMIT LIMIT r COIL B/C COMMON TNS TRANSFORMER PSO 7 YL/2 SW SWIT H o o DOOR SWITCH 6 HL010 YL/4 M HLO HIGH LIMIT OUTPUT ICI INDUCER LIMIT INPUT ICI 9 I ' Y ' ' o'�'o FUSE CONTROL HLI HIGH LIMIT INPUT IFC INTEGRATED FURNACE RLI 3 YL/I �FRS2 FRSI YL/7 6vvvb LC LINE CHOKE AXI I S Y1/5 HLI I YL NOTES- NVL13 I. IF ANY OF THE ORIGINAL WIRING AS SUPPLIED WITH THIS FURNACE MUST BE REPLACED, I NVCII T ,MUST BE WITH WIRE HAVING A TEMPERATURE RATING OF AT LEAST 105 C. MVH 14 2. USER INTERFACE MUST BE INSTALLED FOR PROPER FURNACE INSTALLATION & SET-UP. RD 3. CORRECT PERSONALITY MODULE IS REQUIRED FOR PROPER FURNACE OPERATION, 2 STAGE PERSONALITY MODULE IS SPECIFIC TO EACH MODEL & SERIAL NUMBER, AND IS TO REMAIN BL 2 GAS VALVE WITHIN IT'S ORIGINAL UNIT. — 8R 3 4. THESE LEADS PROVIDE 120V POWER CONNECTIONS FOR ELECTRONIC AIR CLEANER (EAC) uSER AND HUMIDIFIER (HUM). MAX. LOAD: 1.0 AMPS EACH. INTERFACE 5 GREENWLEDUWILLAST BE SOLRIDFONLDURING LAS IF T FAULT WILL E FLASHED RECOVERY. ON RED LED. RECOVERY. 6. YI IS AN OUTPUT ONLY WHEN USED WITH A NON-COMMUNICATING, A/C ONLY, OUTDOOR UNIT. �Snsl-I I 1. LINE CHOKE (LC) NOT USED ON ALL MODELS. 8. IN 24 VOLT MODE, AN OPTIONAL HUMIDISTAT CAN BE CONNECTED BETWEEN THE 'R" AND BK" TERMINALS. FACTORY INSTALLED 'BK JUMPER" ON THE CIRCUIT BOARD MUST BE CUT. �Sns1-2 3 I SEE FURNACE INSTALLERS GUIDE FOR DETAILS. S.$ B I ISns2-2 2 L W2 W1 eK G D R erCY1 Y20� UD2 I I I I U R ei Y' R E V A From Dwg.D343534POl SEE NOTE 6 � A � Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. PUB.NO.12-1286-08 21 Amof iwo SAwdzrd Electrical Data HEATING & AIR CONDITIONING Wiring Diagram 15-PIN CONNECTOR NBK/I BLOWER SEE I. HLI HIGH LIMIT INPUT DOORcoMPARTMEHTNOTE 7� 9 2. PSI PRESSURE SWITCH IST STAGE SWITCH $Af ETY 8 rr INTERLOCK 4. RHI 2�VACOUT SWITCH INPUT BN/I0jr 7113x/10 ;•` LC 1 5. TR 24V RETURN 6 6. BK/1J�"d�v""2�.� 5 BK/8 7. PSO PRESSURE SWITCH OUTPUT 4 WH/7 CM 8. GND GROUND 3 INDOOR s Bx FAN z WN 10, HLO LIMIT SWITCH OUTPUT RD a m i 1 MOTOR I II. MVC VALVE COMMON BN o Lot WH/4 12. PS2 PRESSURE SWITCH 2ND STAGE e 3. MVL GAS VALVE LOW STAGE KNT�e NNNMX YL/BK 4, MVH GAS VALVE HIGH STAGE BK/HUM BK/I� GND JUMPER 15. AXI REVERSE FLOW SWITCH INPUT BK/5 D W /H%IOCM I FIL WH/T OBM COM � o RA OR O O3 x BK/EAC Ai r wH 3 3 RD 3 u is YL/5 TNS_ 8K/4 BL BR GR I I � :120V �RD— YL/4—Q_0Q— YL/2 e O u ' WH/4 BL RD n s O ® W OR— z 3 YL/IBL � o W""TO USER INTERFACE STATUS (SEE NOTE 2) F LTO �... TO PERSONALITY MODULE ' [00 00 n TS2 TSI (SEE NOTE 3) W OD o W W � wt wi erceORerc ri r3o W ' D R4Cfl ' O O W ' (SEE NOTE 6) D A n W W ' t ~ REVERSE LIMIT WIRE BUNDLE SWITCH BLOWER TCO C COMPARTMENT JUNCTION BOX —?<?< o o \m FLAME BURNER roo 3 3 W Y Y SENSOR WH�� COMPARTMENT N�o GR- 33m o GND HSI a H. WH/5' BK I 3 eK/-IO BK/5- RD 2 2 STAGE INDUCER oo� WH/6 3 ...WH.. OR BIR BR 3 2 STAGE LWH/I� GR4IM P� f RD 1 GAS VALVE GND YL/2�— I_115� J PSI PS2 vva —BK/HUM = ru7 - -WH/HUM YL/3 I YL/8 �BK/EAC YL/5 YL/I YI L 9 -�WH/EAC Y FLAME FLAME w ROLLOUT ROLLOUT PRIMARY SEE NOTE 4 $WITCR LIMIT $WITCH $WITCH 2TABLE "A" MOOE.S L J IMPORTANT: oDD2BO60ACV32"" LDD2CI00ACV52" INTEGRATED CONTROL IS POLARITY SENSITIVE, MDD28080ACV32"" LDD2D120AC V52 HOT LEG OF 120V POWER SUPPLY MUST BE CONNECTED TO THE BLACK POWER LEAD AS INDICATED ON WIRING DIAGRAM. . PREFIX MAY BE "A' OR "T" / "^ SUFFIX MAY BE AA THROUGH ZZ 1 � Label all wires prior to disconnection when servicing controls. From Dwg.D343535POl Wiring errors can cause improper and dangerous operation. (continued on next page) Verify proper operation after servicing. 22 PUB.N0.12-1286-08 Electrical Data Akftf6" S*vdard HEATING & AIR CONDITIONING Schematic Diagram 115 VOLT 60 HZ. I PH POWER SUPPLY PER LOCAL CODE Y, _E DIAGNOSTIC CODES IFC t.W RED LED - FAULT Do1a - I Flosh ever 20 seconds xH 'N 2 FLASHES - SYSTEM LOCKOUT 6 FLASHES - 115 VOLT AC r , • +'; x f f RETRIES OR RECYCLES EXCEEDED POWER REVERSED OR IGNITER FAULT I I DOOR '' i I,GR SWITCH WH/I f;YGND 3 FLASHES - PRESSURE SWITCH FAULT 7 FLASHES - GAS VALVE CIRCUIT ERROR K/10 , 8 FLASHES - LOW FLAME SENSE SIGNAL �L,11.E-HH BK 4 FLASHES - OPEN LIMIT SWITCH 9 FLASHES - OPEN INDUCER LIMIT X R- BK/d BK/4 BL 5 FLASHES - FLAME SENSED WHEN 10 FLASHES - COMMUNICATION FAULT NO FLAME SHOULD BE PRESENT CIRC-H BK/7 �120v 24V' CONTINUOUS ON - INTERNAL CONTROL FAILURE IVSIM-H I WH/4 RD GREEN LED - STATUS SLOW FLASH - NORMAL, NO CALL FOR HEAT LC- YL/BK FAST FLASH - NORMAL, CALL FOR HEAT PRESENT ILINE-N WH/I 61 JUMPER GREEN AND RED LEDDS ON CONTINUOUS - INTERNAL CONTROL FAILURE ICIRC-N 1WH/7 •; GREEN AND RED LEDDS OFF CONTINUOUS - FUSE OPEN XF MA-N WH/4 K/8" 4 BL ICM I IND-N WH/6 2 IFAN A 2 WH IGN-N wH/5 R/BK 3 MOTOR I N WARNING CAUTION EAC N WH/7 4 " HAZARDOUS VOLTAGE USE COPPER CONDUCTORS ONLY! I HUM-N I BN/8 5 DISCONNECT ALL ELECTRICAL POWER UNIT TERMINALS ARE NOT DESIGNED 6 INCLUDING REMOTE DISCONNECTS TO ACCEPT OTHER TYPES OF CONDUCTORS. BEFORE SERVICING. 12 V I BN 7 FAILURE TO DO SO MAY CAUSE DAMAGE I R. 2 Iwx FAILURE TO DISCONNECT POWER BEFORE TO THE EQUIPMENT. 8 SERVICING CAN CAUSE SEVERE PERSONAL GND 3 BL 9 INJURY OR DEATH. Ts 4 IWH 1 GN INTEGRATED FURNACE CONTROL IGN-H11 RBK/5 _ REPLACE WITH PART CNT 07081 OR EQUIVALENT TIMINGS e I H51 ELECTRICAL RATING PREPURGE: 0 SEC.; INTERPURGE: 60 SEC, HUM-H 3 I INPUT: 25 V.A.C., 60 HZ. POST PURGE: 5 SECONDS FLANS XFMR SEC. CURRENT: 450 MA. v MV LOAD IGNITOR WARM UP: 20 SECONDS SENSOR MV OUTPUT: 1.5 A 0 24 V.A.C. IAP: 3; TFI: 5 SECONDS EAC-x I IND OUTPUT: 3 PHASE OUTPUT RETRIES: 2: RECYCLES: 10 IGN OUTPUT: 2.0 A 0 12OV.A.C. HEAT ON DELAY: 45 SECONDS FS 2 x CIRC. BLOWER OUTPUT: 14.5 FLA, COOL ON DELAY: 0 SECONDS 25 LRA 0 120 VAC AUTO RESTART: 60 MINUTES HUMIDIFER & AIR CLEANER AUTO RESTART PURGE: 15 SECONDS LO R 3 MAX. LOAD: 1.0 A 0 120 VAC 2 STAG 2 INDUCE � TCO THERMAL LINE )FACTORY HI IBK CUT OUT 24 V WIRING BN BLACK GR GREEN 1 WH WHITE BR BROWN �O PS SWITCHRE •LINE 1 FIELD YL YELLOW RD RED — -24 V f WIRING �OR ORANGE BL BLUE 1 I FRS FLAME ROLLOUT TH 4 R ° SWITCH ev INTERNAL THERMAL WIRE COLOR TR S PROTECTION K1 1 GND $ GAS--� f�, FP FLAME SENSOR BK/1`NUMBER ID (IF ANY) PSI 2 OR REVERSE CHASSIS GROUND �CF CAPACITOR L IN IT L LINE TH 24 VAC (HOT) P52 2 BR pSI pst SWI TCx N NEUTRAL TR 24 VAC (COMMON) f f�� HSI HOT SURFACE I PS3 B 1 ,�-0 ry PRIMARY d� IGNITER p GND GROUND MV MAIN GAS VALVE PSO T YL/2 L/6 Z LIMIT y z COIL B/C COMMON TNS TRANSFORMER Swl Tfx o O DOOR SWITCH 6 HLO HIGH LIMIT OUTPUT ILI INDUCER LIMIT INPUT HLO ID YL/4 �v I 1 1 01.0 FUSE HLI HIGH LIMIT INPUT IFC INTEGRATED FURNACE ILI 9 L I I CONTROL RLI 3 YL/I 2 r FRSI YL/3 YL/7 S"Y'"b LC LINE CHOKE I AXI S YL/5 HL I YL MVL13 �SF ANY OF THE ORIGINAL WIRING AS SUPPLIED WITH THIS FURNACE MUST BE REPLACED, MVC11 1 IT ,MUST BE WITH WIRE HAVING A TEMPERATURE RATING OF AT LEAST 105 C. Mvx LL 2. USER INTERFACE MUST BE INSTALLED FOR PROPER FURNACE INSTALLATION & SET-UP. = I RD 3. CORRECT PERSONALITY MODULE IS REQUIRED FOR PROPER FURNACE OPERATION. 2 STAGE PERSONALITY MODULE IS SPECIFIC TO EACH MODEL & SERIAL NUMBER, AND IS TO REMAIN 1 8L 2 WITHIN IT'S ORIGINAL UNIT. GAS VALVE 4. THESE LEADS PROVIDE 12OV POWER CONNECTIONS FOR ELECTRONIC AIR CLEANER (EAC) BR 3 AND HUMIDIFIER (HUM). MAX. LOAD: 1.0 AMPS EACH. DISPLAY 5. ON POWER-UP, LAST FOUR FAULTS, IF ANY, WILL BE FLASHED ON RED LED. AS GREEN LED WILL BE SOLID ON DURING LAST FAULT RECOVERY. I 1 I 6. YI IS AN OUTPUT ONLY WHEN USED WITH A NON-COMMUNICATING, A/C ONLY, OUTDOOR UNIT.SnsI-I 7. LINE CHOKE (LC) NOT USED ON ALL MODELS. 8, IN 24 VOLT MODE, AN OPTIONAL HUMIDISTAT CAN BE CONNECTED BETWEEN THE 'R' AND "BK" TERMINALS. FACTORY INSTALLED "BK JUMPER" ON THE CIRCUIT BOARD MUST BE CUT. ISnsI-2 3 SEE FURNACE INSTALLERS GUIDE FOR DETAILS. ISns 2-I B 1 Sns2-2 2 L — W1 WI BN G D R B/CYI Y2 O I DD2 I 1 L — RPC FYI — 1 1 I I From Dwg.D343535P01 REV A (SEE NOTE 7) d • Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. PUB.NO.12-1286-08 23 Amof iwo SAwdsrd HEATING & AIR CONDITIONING Field Wiring Communicating Indoor Unit with Communicating Comfort Control and Communicating Outdoor Unit COMMUNICATING COMMUNICATING MODE COMMUNICATING COMFORT CONTROL INDOOR UNIT OUTDOOR UNIT 8K NOTE 4 W3 NOTE 7 W2 IFGFND WI ------ FACTORY WIRING FIELD WIRING G aT TERMINAL MAY OR MAY NOT BE PRESENT ON D D D UNIT NOTES: NOTE 5 I. SEE WIRING DIAGRAMS IN SERVICE FACTS FOR COMPLETE WIRING INFORMATION. R R 2. LOW VOLTAGE WIRING TO BE NO. 18 AWG MINIMUM CONDUCTOR. NOTE 6 3. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. B B B POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES, 4. IN COMMUNICATING MODE, UNUSED TERMINALS YI ARE NOT FUNCTIONAL. DO NOT USE. 5. "D" IS THE DATA LINE. INSTALLER TO SELECT A WIRE COLOR. Y2 6. TO CONNECT OPTIONAL DEVICES (SUCH AS A FLOAT SWITCH) WIRE IN SERIES FROM INDOOR "R" TO COMFORT CONTROL "R". 7. WHEN CONVERTING OUTDOOR UNIT TO 24 VAC MODE, USE 24 VAC HARNESS ACCESSORY (BAYACHP024s). 0 PRINTED FROM D802614POI REV01 24 PUB.NO.12-1286-08 Communicating Indoor Unit with Communicating Comfort Control and 24VAC Single Stage Cooling COMMUNICATING COMMUNICATING MODE 24 VAC OUTDOOR UNIT COMFORT CONTROL INDOOR UNIT I-STAGE AC ONLY BN W3 NOTE 4 W2 IFGFND WI ------ FACTORY WIRING FIELD WIRING El TERMINAL MAY a OR MAY NOT BE PRESENT ON D D UNIT NOTES: NOTE 5 I. SEE WIRING DIAGRAMS IN SERVICE FACTS R R FOR COMPLETE WIRING INFORMATION. NOTE 6 2. LOW VOLTAGE WIRING TO BE NO. 18 AWG MINIMUM CONDUCTOR. B B B 3. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. YI YI 4. IN COMMUNICATING MODE, UNUSED TERMINALS ARE NOT FUNCTIONAL, DO NOT USE. 5. "D" IS THE DATA LINE. INSTALLER TO SELECT A WIRE COLOR. Y2 6. TO CONNECT OPTIONAL DEVICES (SUCH AS A FLOAT SWITCH) WIRE IN SERIES FROM INDOOR "R' TO COMFORT CONTROL 'R". PRINTED FROM D802614P02 REV01 0 24VAC Mode Indoor Unit with 24VAC Comfort Control and 24VAC Single Stage Cooling TYPICAL 24 VAC COMFORT CONTROL 24 VAC MODE 24 VAC OUTDOOR UNIT (SEE CONTROL INSTALLER'S GUIDE) INDOOR UNIT I-STAGE AC ONLY BN NOTE 4 W3 W3 NOTE 5 W2 W2 IFGFND ------ FACTORY WIRING WI WI FIELD WIRING Q TERMINAL MAY T OR MAY NOT G G BE PRESENT ON UNIT El NOTES: I. SEE WIRING DIAGRAMS IN SERVICE FACTS R R FOR COMPLETE WIRING INFORMATION. 2. LOW VOLTAGE WIRING TO BE NO. 18 AWG MINIMUM CONDUCTOR. B B B 3. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. YI 11111 YI YI 4. OPTIONAL FIELD WIRING. CONNECT ONLY IF THESE HEATING STAGES ARE USED, 5. CONNECTIONS TO "R' , "BK', AND "0" MUST BE MADE AS SHOWN Y2 Y2 FOR PROPER OPERATION WITH OPTIONAL HUMIDISTAT IN COOLING. FACTORY 'R" TO "BK" JUMPER ON TERMINAL BLOCK MUST BE REMOVED ON AIR HANDLING UNITS. FACTORY 'R" TO "BK" JUMPER ON FURNACE CONTROL MUST 8E CUT ON FURNACES. NOTE 5 0 PRINTED FROM D8026I41`03 REV01 NOTE: To locate the BK to R jumper on the lFC board,see page 28. 24VAC Mode Indoor Unit with 24VAC Comfort Control and 24VAC 2-Stage or 2-Step Cooling TYPICAL 24 VAC COMFORT CONTROL 24 VAC MODE 24 VAC OUTDOOR UNIT (SEE CONTROL INSTALLER'S GUIDE) INDOOR UNIT 2-STAGE OR 2-STEP AC BK NOTE 4 W3 W3 NOTE 5 IFGFND W2 W2 ------ FACTORY WIRING FIELD WIRING WI WI TERMINAL MAY T OR MAY NOT 8E PRESENT ON UNIT G G NOTES: I. SEE WIRING DIAGRAMS IN SERVICE FACTS El FOR COMPLETE WIRING INFORMATION. 2. LOW VOLTAGE WIRING TO BE NO. 18 AWG MINIMUM CONDUCTOR, R R R 3. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. B B B 4. OPTIONAL FIELD WIRING. CONNECT ONLY IF THESE HEATING STAGES ARE USED, 5. CONNECTIONS TO 'R" , "BK", AND '0' MUST BE MADE AS SHOWN FOR PROPER OPERATION WITH OPTIONAL HUMIDISTAT IN COOLING. YI YI El FACTORY 'R" TO 'BK' JUMPER ON TERMINAL BLOCK MUST BE REMOVED ON AIR HANDLING UNITS. FACTORY 'R" TO 'BK" JUMPER ON FURNACE CONTROL MUST BE CUT ON FURNACES. Y2 Y2 2 6. SEE USER INTERFACE 24 VAC MODE SETUP MENU FOR IST STAGE CFM OPTIONS. 2-STAGE = 39-64% 2-STEP = 65-801 NOTE 5 0 PRINTED FROM D80261004 REV01 NOTE: To locate the BK to R jumper on the IFC board,see page 28. 24VAC Mode Indoor Unit with 24VAC Comfort Control and 24VAC Single Stage Heat Pump TYPICAL 24 VAC COMFORT CONTROL 24 VAC MODE 24 VAC OUTDOOR UNIT (SEE CONTROL INSTALLER'S GUIDE) INDOOR UNIT I-STAGE HEATPUMP BN NOTE 4 NOTE 5 W3 W3 I F.FND W2 W2 ------ FACTORY WIRING FIELD WIRING WI WI X2 TERMINAL MAY aT OR MAY NOT BE PRESENT ON UNIT G G NOTES: El I. SEE WIRING DIAGRAMS IN SERVICE FACTS FOR COMPLETE WIRING INFORMATION. 2. LOW VOLTAGE WIRING TO BE NO. 18 AWG MINIMUM CONDUCTOR. R R R 3. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. B B B 4. OPTIONAL FIELD WIRING, CONNECT ONLY IF THESE HEATING STAGES ARE USED. 5. CONNECTIONS TO 'R' , 'BK', AND "OL MUST BE MADE AS SHOWN YI YI YI FOR PROPER OPERATION WITH OPTIONAL HUMIDISTAT IN COOLING. FACTORY 'R" TO 'BK" JUMPER ON TERMINAL BLOCK MUST BE REMOVED ON AIR HANDLING UNITS. FACTORY 'R" TO 'BK" JUMPER ON FURNACE CONTROL MUST BE CUT ON y2 Yp FURNACES. 6. ON FURNACE APPLICATIONS, COMFORT CONTROL MUST BE DUAL FUEL COMPATIBLE (SEE CONTROL INSTALLERS GUIDE) OR MUST USE TAYPLUS103. 0 0 0 PRINTED FROM D802614P05 REV01 NOTE: To locate the BK to R jumper on the IFC board,see page 28. 24VAC Mode Indoor Unit with 24VAC Comfort Control and 24VAC 2-Stage or 2-Step Heat Pump TYPICAL 24 VAC COMFORT CONTROL 24 VAC MODE 24 VAC OUTDOOR UNIT (SEE CONTROL INSTALLER'S GUIDE) INDOOR UNIT 2-STAGE OR 2-STEP HP BK - BK NOTE 4 NOTE 5 F.F ND W3 W3 ...... FACTORY WIRING FIELD WIRING W2 W2 TERMINAL MAY OR MAY NOT BE PRESENT ON UNIT WI WI 2 NOTES: G G I. SEE WIRING DIAGRAMS IN SERVICE FACTS FOR COMPLETE WIRING INFORMATION. 2. LOW VOLTAGE WIRING TO BE NO. 18 AWG MINIMUM CONDUCTOR, El 3, BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. R R R 4. OPTIONAL FIELD WIRING, CONNECT ONLY IF THESE HEATING STAGES ARE USED. B U B 5. CONNECTIONS TO 'R- "BK', AND "0" MUST BE MADE AS SHOWN FOR PROPER OPERATION WITH OPTIONAL HUMIDISTAT IN COOLING. FACTORY "R" TO "BK' JUMPER ON TERMINAL BLOCK MUST BE REMOVED ON AIR HANDLING UNITS. YI YI FACTORY "R" TO "BK' JUMPER ON FURNACE CONTROL MUST BE CUT ON FURNACES. 6. ON FURNACE APPLICATIONS, CON FORT CONTROL MUST BE DUAL FUEL COMPATIBLE Y2 (SEE CONTROL INSTALLERS GUIDEI OR MUST USE TAYPLUS103. Y2 Y2 T. SEE USER INTERFACE 24 VAC MODE SETUP MENU FOR IST STAGE CFM OPTIONS. 2-STAGE = 39-64% 2-STEP = 65-80% 0 tQ 0 PRINTED FROM D802614P06 REV01 NOTE: To locate the BK to R jumper on the IFC board,see page 28. Wiring Notes: Amof iwo SAwdsrd H E A T I N G & AIR CONDITIONING O O O 7� 4 000 � J + O O O mi ID LJ � LJI�@i 0 Lo 19 R �O 0 19 19 LO - D BUu�mper CII'1 L'I L'I u U O /C O u LS O The factory installed jumper be- tween"R"and"BK"on the circuit board must be cut if an optional Humidistat is installed. HUMIDISTAT HOOKUP-24 V Mode ONLY If an optional humidistat for humidity control in cooling is used, the factory installed"BK Jumper"must be cut. The BK Jumper must also be cut if a multi-zone controller is connected or'CONT402 is installed and using the BK enabled feature. See the 24VAC field hookup wiring diagrams for more information. 28 PUB.NO.12-1286-08 ¢O S z V> O Z) H - N - as CO M _a W N w�LL �OLLz OLLz N a0 co V m CO p............................a CO CD o� r Z C7 m LO n O z T T C7F d J W d Z ~ C) N N N Q _ � Q r r W J W O r N m C _ 0C)a = — °� fn 2 W Z ro n............................a _ U w u? -- O o O CD CD CD m m m m (� W o i r N N N N N N N +-• L Z ZQ W Q > > > > > > > J Z e lL QQQ QQ QQ i G) W O O O O O O O cc 7 Co O W O 00 O N It .s Q — ++ fn N �M N mmm NN Zcoo cc CI CI O cn > Z Q[[[[[[[[[ [ [ [ 0 C> 0 W Z =Z O Z e O O M X o p_________________ Q .................................. - CD W O O m d w I Z V O O O — O r2 W w rL M M _ _ e - -o 3 3 3 3.n 3.n 3 3.n 3.n m o O m 3 3 3 3 M 3 3 O O 3 3 0 3 3 0 0 LU LLI cYiOz W6 �.a6 �H m zOO J w d z 3 3 3 3 3 3 3 3 3 3 H Q LI J --- --- --- --- --- w w 03 JUU o Q= ¢ LU IL Q = �Q W N J O r N o �z L QZ �zw o� w z N LU M Z V>— — Z co o> c> ww¢ a 0 x N w Q V N o Q W Q Z 2 dpO 7co - = x r Q � O O QU r Z T r T Z h O O T T LU Z LU I o n O e J F_ Z r = O N Q T N m 0 N w - N Uo o co co m m Q Q �_ v w Q Q Q Q 0 0 (O 00 O N Q ~ cc m m N � Z aa«<<<<<< < < o0 0 cq 0 wo a««<<<<<< < < o0 0 0 e= a««<<<<<< < < o Z W _ _ FO w W — W M D M _ _ I ti 41" T rL — M M LLJ 0 LLB th W J �z w O—z W V w¢ ¢p w Z U � J>V O V— LU v JO- v zap oo azO i—wz co 0_ —Z Oac JO � v O x Q Amafew S7itqdwd HEATING & AIR CONDITIONING PUB.NO.12-1286-08 31 C US CO 4&two S7izffd4zrd Intertek HEATING & AIR CONDITIONING American Standard 12/16 Heating&Air Conditioning 6200 Troup Highway Tyler,TX 75707 Since American Standard Heating&Air conditioning has a policy of continuous product improvement,it www.arnericanstandardair.corn reserves the right to change design and specifications without notice. NOTICE V TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED Cl DO NOT OCCUPY CI APPROVED PERMIT#: D AM ❑ PM DATE: JOB ADDRESS: LOT#: PROJECT: TYPE OF INSPECTION: OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. Cl CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION AMW✓�_`�_: THEACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE 0 PLANNING 0 CIVIL 0 BUILDING CITY OF ARLINGTON CITY OF ARLINGTON Dw 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 -BUILDING PERMIT 18712 35TH AVE NE Permit#:3557 Permit Expiration Date:05/18/2021 Parcel#: 00946600000500 Valuation: .00 f)WNE-K APPLICANT CONTRACTOR KINFORD SHANNON M/BARTRAM CM Heating Inc CM Heating Inc DONNA M 18712 35TH AVE NE 1415 Broadway 1415 Broadway ARLINGTON,WA 982223 Everett,WA 98201 Everett,WA 98201 425-259-0550 425-259-0550 LIC:CMHEAMH877DN EXP:03/15/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR - LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: OCC LOAD: ai PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. /CY S01 FOSt2Y 11-19-2020 Signature Print Name Date Released By Date CONDITIONS _ APPROVED AS SUBMITTED.APPROVED JOB COPY SHALL BE ONSITE FOR INSPECTION. CALL FOR INSPECTION THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES . Date Description Fee Amount 11/19/2020 Inspection Fee $75.00 11/19/2020 Forced Air Heat $0.00 11/19/2020 Mechanical Base $25.00 11/19/2020 Processing/Technology Fee $25.00 Total Due: $125.00 Total Payment: $0.00 Balance Due: $125.00 CALL FOR INSPECTIONS _ Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 3557 Permit Date: 11/19/20 Permit Type: RESIDENTIAL MECHANICAL Project Name: Kinford Applicant Name: CM Heating Inc Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett,WA 98201 Contact: Debbie Bauers Phone: 425-259-0550 Email: debbie@cmheating.com Scope of Work: Replace gas furnace Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: Permit Expires: 05/18/2021 Form Permit Type: Status: LASERFICHE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning KINFORD 120 SINGLE 00946600000500 18712 35TH AVE NE SHANNON FAMILY M/BARTRAM DONNA M RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Plumbing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751W ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION UBI 605890285 ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 03/31/2021 R00.FURNACE 03/31/2021 03/31/2021 BUILDING Approved FINAL Fees Fee Description Notes Amount Inspection $75.00 Forced Air Heat fee per Btu $0.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Credit Card Service $3.75 Total $128.75 Attached Letters Date Letter Description 11/19/2020 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 11/19/2020 Debbie Bauers 83507751 $125.00 11/19/2020 83507751 Raelynn Jones $3.75 Outstanding Balance $0.00 Uploaded Files Date File Name 09/24/2021 9760844-3557 IC 3.31.2021 Final.pdf 11/19/2020 7725545-3557 Cut Sheets.pdf 11/19/2020 7725546-3557 Application.pdf