HomeMy WebLinkAbout17601 59TH AVE NE_BLD3549_2026 Agmhl an Win, CITY OF AR.LINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT Permit#:3549 17601 59TH AVE NE PERMIT EXPIRES 190 DAYS AF7'FR DATE OF ISSUANCE. Parcel#:31052200400200 Valuation: 700.00 OWNER APPLICANT CONTRACTOR PUBLIC UTILITY DISTRICT NO 1 Suppression Systems Inc. Suppression Systems Inc PO BOX 1107 3077 20th Street E, Suite B 3077 20th Street E,Suite R EVERETT,WA 98206 Fife,WA 98424 Fife,WA 98424 253-926-3300 253-926-3300 LIC`.:SUPPRSI044RR EXP: 1 2/1 612 02 2 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRiMON PERMIT TYPE: Fire Sprinkler CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: I OCC LOAD: . PERMIT APPROVAL The issuance or granting of this permit shalt not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such eons►ruction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor_ I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED T14ERE;BY,NO PERSON WILL BE EMPLOYED iN VIOLATION OF THE LABOR CODE.OF THE STATE OF WASHINGTON RELATING IUO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION iS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID, IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED, IBC110fIRC I I0. SALES TAXX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded C' of Arlington#3101 j Signature Print Name Date Released By Date --CONDLT1t.©NS Fire AlarmNESDA 1.Permit and set of approved plans to remain on site during installation.Installers shall present NIC>ET It certification upon request.2.Battery load test required,switch system to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power.3.Trouble condition to be verified for initiation,notification and signaling circuits.4.Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2).Clean Agent System 5. Functional acceptance test to be witnessed by AH]and comply with NFPA 2001 Section 7.7.The record of completion forms for each system shall be submitted prior to project close-out.Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORD,TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN'(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILI.,REQUIRE:SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 03/22/2021 Processingfrechnology Fee $25.00 03122t2021 Fire System Plan Review $100.00 03/22/2021 Fire Alarm System Permit $300.00 Total Due: S425.t10 Total Payment: $0.00 Balance Duet $425.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections A When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon City of Arlington Fire Department � y January 11, 2021 Permit Number: BLD 3549 Project Address: 17601 591h Avenue NE, Arlington Project Description: Fire Plans for Snohomish PUD Modular Data Center- Revised Contractor: Nina Reeves Suppression Systems Inc. 3077 20th Street E, Suite B Seattle, WA 98108 Re: Fire Suppression Shop Drawing Review Comments The Arlington Fire Department has completed a review of the shop drawings submitted and approves the submitted plans with the following conditions: Fire AlarmNESDA 1. Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request. 2. Battery load test required, switch system to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for initiation, notification and signaling circuits. 4. Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection (NFPA 72 Section 7.5.2). Clean Agent System 5. Functional acceptance test to be witnessed by AHJ and comply with NFPA 2001 Section 7.7. The record of completion forms for each system shall be submitted prior to project close-out. Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the system at project completion. Final approval will not be provided until all conditions are verified. Please call at least 48 hours in advance to schedule an inspection. Sincerely, ". Mike Makela Assistant Fire Chief COPY Arlington Fire Department OFFICE i 1 41 AL '8/7 Permit#: 3549 Permit Date: 11/16/20 Project Name: Snohomish County PUD Company/Applicant Name: Suppression Systems Inc. Company/Applicant Address: 3077 20th Street E, Suite B City, State, Zip: Fife, WA 98424 Contact: Nina Reeves Phone: 253-926-3300 � � b�, rl GvU�rfi Email: nina@suppression.com Permit Type: Fire Sprinkler Valuation: 700.00 Square Feet: 0 Number of Stories: 0 Type of Construction: Occupancy Type: Scope of Work: Fire Suppression for Modular Data Unit MIC/Opportunity Zone: Permit Issued: Permit Expires: 05/15/2021 DNU: Status: IN PROCESS Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31052200400200 17601 59TH AVE NE PUBLIC UTILITY 489 Other Utilities DISTRICT NO 1 NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License# Suppression Systems Inc Nina Reeves 253-926-3300 3077 20th Street CONTRACTOR Labor and SUPPRSI044RR E,Suite B Industries Plan Reviews Date Review Type Description Assigned To Review Status 11/16/2020 Fire Sprinkler Building In Review 11/16/2020 Fire Sprinkler Mike Makela In Review Fees Fee Description Notes Amount Fire Sprinkler Permit Commercial NFPA 13/13R $75.00 Processing/Technology Fee $25.00 Fire System Plan Review Table 4-2 or 4-10 $100.00 Total $200.00 Notes Date Note Created By: 1 1 11 6/2020 Contractor needs out of city license prior to issuance.Emailed the application. Kristin Foster Uploaded Files Date File Name 11/16/2020 7704665-3549 Application.pdf 11/16/2020 7704664-3549 PUDFIRE+SUPPRESSION t DRAWINGS 10-29-20.pdf Raelynn Jones From: Nina Reeves <nina@suppression.com> Sent: Friday, December 4, 2020 9:08 AM To: Mike Makela (North County) Cc: Raelynn Jones Subject: RE: SnoCo PUD#1 Clean Agent Submittal [NOTICE: This message originated outside the City of Arlington mail system.-- DO NOT CLICK on links or open attachments unless you are sure the content is safe.] Good morning Mike, This system has all three of those systems pre-installed in a modular data center by others. The unit will be delivered to the site, Suppression Systems will make all the final connection, inspection and start-up of the system. I submitted what applications I thought we needed, if separate permits are required please advise. If you have further questions please call me on my cell as I am working remote.253-229-3 847. 01yave a W{rondet ful Daw, -OVLna Of.oTsev" Suppression Systems Inc. Special Hazard Fire Protection 3077 201h Street East, Suite"B" Fife, WA 98424 Phone: 253-926-3300 Fax: 253-926-3306 From: Mike Makela [mailto:mmakela@northcountyfireems.com] Sent: Friday, December 04, 2020 8:35 AM To: Nina Reeves Cc: Raelynn Jones Subject: SnoCo PUD#1 Cleant Agent Submittal Nina, I have a question to ask regarding your submittal for the clean agent system proposed for the Module Data Center for Snohomish PUD#1 in Arlington, WA. 1. Is the permit submittal intended to include the clean agent system,the Vesda system, and fire alarm work all as one submittal? Thanks, Mike Makela, FM Assistant Chief— Community Risk Reduction North County Fire EMS Arlington Fire Department 8117 267th St NW Stanwood WA. 98292 (360) 629-2184 Office (360) 502-6184 Cell mmakela(a',northcountyfireems.com 1 mmakela(@arlingtonwa.gov _A&L- %(MTn tovwrt io �-X 2 FIRE SPRINKLER 1 PERMIT APPLICATION IN Department Department of Community &Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF COMPLETE AND SCALED PLANS, TWO(2) SETS OF HYDRAULIC CALCULATIONS, TWO (2) SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE SPRINKLER PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION. Type of Permit: ✓❑ New Fire Sprinkler ❑ Fire Sprinkler Add/Aft ❑ Underground Fire Line Project Address: 17601 59TH AVE NE ARLINGTON, WA 98223 Parcel ID#: 31052200400200 Project Valuation: 700.00 Number of Heads: 2 Building Area(Sq Ft):1,1345 Owner: SNOHOMISH COUNTY PUD NO. 1 Phone Number: NA Address: CLEAN AGENTFIRE City:NA State: NA Zip Code: NA Contact Person:NA Phone Number: NA Cell Phone: NA Email: NA Address: NA City: NA State: NA Zip Code:NA Contractor: SUPPRESSION SYSTEMS INC. Phone Number: 253-926-3300 Address 3077 20TH STREETE, SUITE B City:FIFE State: WA Zip Code:98424 Contractor's License Number: S U P P RS 1044RR Expiration: Contact Person: NINA REEVES Email:nina@suppression.com I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accordance with the laws,rules and regulation of the State of Washington. ��� ^�� 10/29/2020 Applicants Signature Date Nina Reeves Print Applicants Nail A. SUPRESSION SYSTEMS, INC. --� SPECIAL HAZARD FIRE PROTEC. _)N 3077 20TH STREET EAST, SUITE B FIFE, WA 98424-1798 Nina Reeves Project Engineer Phone (253)926-3300 • Fax(253)926-3306 nina@suppression.com CCB132701 SUPPRSI044RR 4� '-M Permit# Accepted By -- Amount Deceived Receipt# Date Recelved WEB Forms—131 Page 1 of 1 6/16LP i I Nina Reeves From: Nina Reeves Sent: Wednesday, November 04, 2020 1:50 PM To: 'Raelynn Jones' Cc: Kristin Foster;Justin Carter Subject: 2060 permit submittal RE: 17601 59th Ave NE Good afternoon Raelynn, These will go out in the mail 11-06-20. &am a Woadet ful cDaq, OVina ON. 01""" Suppression Systems Inc. Special Hazard Fire Protection 3077 20Th Street East, Suite "B" Fife, WA 98424 Phone: 253-926-3300 Fax: 253-926-3306 From: Raelynn Jones [mallto:riones(&arlingtonwa.q Sent: Wednesday, November 04, 2020 1:35 PM To: Nina Reeves Cc: Kristin Foster Subject: 17601 59th Ave NE Good Afternoon Nina, We received the Fire Sprinkler Permit Application, however we will require the hard copies to be submitted as well.The requirements are listed at the top of the application.You may submit the required documentation to our drop box located at the address listed below in my signature. Please feel free to reach out should you have any questions.Thank you Sincerely, Raelynn Jones Permit Technician City of Arlington Community& Economic Development 18204 591h Ave NE Arlington,WA 98223 Office: 360-403-3436 www.arlin tonwa. ov 1 i i Q Some online services are currently Unavailable. See a lift of service outage. !IP ni%-agov agencyLy a -status). Local offices are closed to the public. Please call your nearest L&I office for local assistance .(htta<.r,In,._gov/agency/contact/Notfice-locations),between 8-5 Pacific Time weekdays,or dial 360-902-5800. wasnmgmevanm Labor&�s��eo Industriesmiof(htti2s://Ini wa.gov), SUPPRESSION SYSTEMS INC Owner or tradesperson 3077 20th Street East Principals Suite B TUCK,STEVEN HAROLD,PRESIDENT FIFE,WA 98424 253-926-3300 TUCK,ZACHARY STEVEN,VICE PIERCE County PRESIDENT DEPALMA,VINCENT J,VICE PRESIDENT (End: 11/06/2008) Doing business as SUPPRESSION SYSTEMS INC WA UBI No. Business type 600 212 586 Corporation Governing persons STEVEN H TUCK ZACHARY TUCK; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. SUPPRS1044RR Effective—expiration 12/19/1996-12/16/2022 Bond No bond accounts during the previous 6 year period. Insurance Everest Indemnity Ins Co $1,000,000.00 Policy no 51 GLO12885201 Received by L&I Effective date 01131/2020 02/01/2020 Expiration date 02/01/2021 Everest Indemnity Ins Co $1,000,000.00 Policy no 51 GLO12885101 Received by L&I Effective date 01/31/2020 02/01/2020 Expiration date 02/01/2021 Insurance history Savings (in lieu of bond) $12,000.00 Received by L&I Effective date 12/05/2001 12/23/1996 Release date Impaired date N/A N/A Savings account ID 7000079421 Savings history Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Certifications & Endorsements OMWBE Certifications No active certifications exist for thls buslness. Apprentice Training Agent No active Washington registered apprentices exist for this business.Washington allows the use of apprentices registered with Oregon or Montana.Contact the Oregon Bureau of Labor&Industries or Montana Department of Labor &Industry to verify if this business has apprentices. Workers' Comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 378,129-00 Doing business as SUPPRESSION SYSTEMS INC Estimated workers reported Quarter 3 of Year 2020"21 to 30 Workers" L&I account contact T4/CASSANDRA SMITH(360)902-5632-Email:SMCA235@lni.wa.gov Public Works Requirements Verify the contractor is eligible to perform work on public works projects. Required Training—Effective July 1,2019 Exempt from this requirement, Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace Safety & Health Check for any past safety and health violations found on jobsites this business was responsible for. No inspections during the previous 6 year period SUPRESSION SYSTEMS, INC. SPECIAL HAZARD FIRE PROTECTION �-- 3077 20TH STREET EAST, SUITE B FIFE,WA 98424-1798 (253)926-3300 FAX(253)926-3306 Project Snohomish County—City of Arlington, WA Modular Data Center Building Clean Agent Fire Suppression Summary This project consists of a clean agent fire suppression system (Novec) and associated detection system intended to protect the modular data center. Initiation is by cross-zoned smoke detection (photoelectric smoke detector or air sampling smoke detection) or by manual release. My conclusion is that the system design is adequate for the application and meets the requirements of the applicable codes and standards. Nathan Scherneck NICET#111032 Kristin Foster From: Kristin Foster Sent: Thursday,January 21, 2021 2:48 PM To: nina@suppression.com Subject: Snohomish County PUD Permit Good Afternoon, I'm working on preparing the fire suppression permit for the Modular Data Unit and needs some information in order to appropriately calculate the fees. Please provide the following information. • Valuation of just the alarm system including labor • Valuation of the Vesda system including labor • Valuation for the clean agent Feel free to reach out should you have any questions. Thanks, Kristin Foster Permit Technician City of Arlington 18204 59th Ave NE 360-403-3549 kfoster@arlingtonwa.gov 1 i Mechanical General Notes: Piping CB - ; � - 1.For 380 pslg systems,schedule 40 black or galvanized pipe may be used as follows: XFRSW PNL GHA POLL MIM POWER i'i °T - - Aa3 Grade A,ERIN sizes 114 in.through 3 in.threaded end Q ATS1 480V 70NE � A-63 Grade A,ERW wet dad connections 1141n.through 31n, A-53 Grade A,B Seamless with welded or threaded connections sizes Q 114 in, through S In. �t A A-106 Grade A,B,C welded or threaded connection 114 In.through 3 In.400A BUSWAV 2 Installation Q f1/11/2010& ISSUED FOR CLIENT REVIEW 1.Cylinder location to be maintained at an ambient temperature of OC NOTFOR CONSTRUCTION (32F)or 490(120F) / : 2.Single cylinder straps when attached to solid walls should use star ENGINNER STAMP grlepin alloy expansion shields for use with machine bolts(or equivalent).Lead shields are not acceptable.Minimum bait size of 3/8" 120KVAt1PSA 120KVAUPSA 3.Pipes to be swabbed clean Internally of all cutting oil,metal chips, u' /d WITH BYPASS BATTERY PNILUOSA etc.prior to assembly using degreasing solvent and rags. CABINET CASKIIS 4.All threaded joints to use Teflon tape or similar lubricant applied to XFMR-A "�� S.Pipmale ing shall be hung secure) as p p g y per ANSI 831.1, S.Piping to be fastened securely and braced against thrust forces at NICE T all nozzles and change direction fittings. 12CKVAUPS8 120KVAUPSO PNLUDSB 7.Piping 9 tubing should be reamed free of burrs and ridges. Nathan Scherneck W'ITHBYPASS BATTERY` 160KVA 208V 8.Before Installing nozzles,all pipes to be pressure tested for leakage\Y CABINET CABINETS NICET8 XF•L1it•8 and blown out using dry compressed air or nitrogen Flre Narmsystemsrems,Level lv I. All nozzles to be mounted with nozzle orientation as shown. Special pprovds5ystems,Level III 10.No deviation may be made to piping layout without the approval of A the Installing company.Pipe lengths are approximate and not to be ® Approved used for prefabrication. ❑ Approved As corrected am 00A BU3WQY' 11.In total flood systems doors,windows,etc.to be sealed against ❑ Revise And Resubmit v B � - • � e � I Y � ❑ ForYourinformation And Use UA lose of agent using weather strip or"sweeper"gaskets to aid in ❑ Incomplete Submittal retention of extinguishing agent. lam ev I 12.Quantity of NOVEC 1230 supplied is based on calculations done using drawings and information supplied,Additional gas requirements due to changes In dimensions,uncloseable opening or other FIRE ALARM ) conditions not indicated In the information received will be extra. M20 PNL GHA MIN POWER C,D11M HOVE 13.Dimensions shown on drawings are for estimation and calculation nsmnE uvrxrwf J 4WV PW 70NE SECURITY PANEL 1? purposes only,Actual site conditions may require some changes.Any BACKBOARD major deviations must be approved prior to completion. '=s =% CIS Discharge Nozzles SCALE 114's1'41" Nozzles moat be located at or near the ceiling with the halfway point between the two vertical orlflce layers no more then 4ft Sin(1.348m) below the ceiling.The maximum height for a single liar of nozzles Is 18ft 41n(6.688m)from the floor to ceiling.For calling heights greater than 18ft 41n(6.688m),additional tiers may be installed to that the M-M maximum distance between the floor and the lowest row does not MERIDIAN MAMA _ exceed 18ft 4in(6,688m)and the maximum distance between rows ,e. AcnATOR ` , 1/41n Is mm]NPT doos not oxceed 18ft 41n(6,688m).Each nozzle must be positioned PROTECTION PN 17MI(OS•101) To 1/41n IS mm] vertically.Installed either on the bottom or top of a vericul pipe JIC ADAPT PN 1866255 R * section and should be placed as close to the cylinders as possible to ELECTRIC (SEE NOTES minimize system piping,The calling tiles around each nozzle must be Sv ACTUATOR '� i i�t FOR - clipped to hold them in place during the discharge and.to prevent damage, two «c..wn znamcr wra l:` .-i rt LIQUID _ QUID LEVEL JA R TO V41n[8 mm]T rw nr,rnucmuumm �.. JICia�wP« ao.em.wcer.c PN ADAPTER v«,ra«c PN 18626 Dlscwwc,O PRESSURE swtt Room Volume and Agent Requirement Calculations: +aoprv.rwa�wxo«im cxoms "-'4.�- \ PN 18773(OS•1401) Inside Dimensions■47.26 X 24 X 11,2 ,mrorancrtnmem.e:uwva t{ "�o�j�ra`` E Total Volume a 12 t, �.�. \ (COMES IN VARIOUS LENGTHS) A14.69L concentration-618 LBS Q CLEAN AGENT VALVE-� \ Total Agent Supplied-518 LIRS Q } "ems>•• ,,� *Agent requirements calculated per NFPA 2001(2012),section 6.4.2.E at W mru a n um CLEAN AGENT- `\ SUPFAV1SMY PRESSURE SWITCH 70F.at Oft above seal level,Refer to hydraulic calculation files for Z PRESSURE GAUGE \ additional details. Q a .vcnww:o®rnaowwm�aua \ 2 e ruse RUPTURE - CLEAN AGENT CYLINDER 'For energized electrical hazards less than 480 Volts.Equipment In = V (COMES IN VARIOUS SIZES; excess of 480 Volta must be de•energized prior to agent discharge or J a ""v" «° ' °ROC r�I�EREN�I�mSHovyN design concentration I agent quantity must be Increased.Per FM data = � aa- r mml a,uprr.cal rupM..l...,.. sheet 4-9. y O TYPICAL MASTER CYLINDER It «r .m1 aa.a:col rYn,rV TRIM DETAIL O W mm" .salons,.- �� .res �L MECHANICAL BOM F- Z LL �., FICE COPY PNe DESCRIPTION City. z y d") 22s84618: Cylinder,LV 4t10 SBMM.600 b w1616 ft.Nevss 1230 t W (3 AAP v law Cylinder well bracket•24• 1 Z --IW49 Hoes,Fat,3�181rxh,114 inch JlC Femur llnMn�24t11�t_IIIIfA,__ 1 /A 18773 _Swath,Discharge Pressure 19633 Nou1e,360 dog.Brass _ 3_ W 20722 Actuator.Vahre,Electric.w/Supervls"lime switch _ t W •�)t��'��'���'' aC�' 1 Manuel Valve Actuator 1 C �1 rt? .L 1 1 iOF A ,�IN(�f1 - - -C'suyo Assembly ProsaOle,Novec 1230_RuItl,500 Sodas Switch Assembly Low Pressure Beponlow.,500 series t ICsN Sign,Warning,Exh.'LemArea',CteanAaent 4 W BUILDING DEPARTMENT - W APPROVEDN gqn,Waming,Entrance.'Do Not Enter-a..;ApOntt 4 ' N DRAWN BY: KR ---� DATE Z Z BY DATE: 11/05/2019 wveKriwn NO CHANGES AUTHORIZED JOB#: xxxxx UNLESS APPROVED BY THE ., SHEET NO: BUILDING INSPECTOR FP-1 Electrical General Notes: 1 - �H]wR —1 '` —�1 1.Wiring shall be looped through device terminals.Wire must be cut �.• '` ��- for In and out circuits Mott��Aa10 XFRSW anal and PNL GHA PQM'MINI POWER �� have 2.•T"-Tapping of wiring is prohibited,except for class"B"style W, 4BOV ZONE ATS 1 _ ' I signaling line circuit(SLC)addressable loop wiring x 1 The fire alarm control p power extender panels are not to be x �1 � M r,�q 04Ix 0s used as a terminal cabinet.All wiring Into panels shall be landed onto e urs PLENUM "12 iAoi3 A I noose appropriate terminal only.No splicing or through wiring will be J allowed In panels D1104 400A BUSWAY 4.All fire alarm wiring must test free of opens,shuns,and grounds 1 A�100s B 5,All wiring must enter at the top of the fire alarm control panel and/� 11/1/20/8 power extender panels t ISSUED FOR CLIENTMEW RIAPLENUM ., .w. " ,. ,�k ,R ,,M, ., 6.Thiscontrol requires pa panel r ulnae connection to separate dedicated A/C NOT FOR CONS TRUC710N branch circuit.Fallow these guidelines when connecting the AIC SIO S: branch circuit ENGINNER STAMP j Label the branch circuit fire alarm breaker and it shall be locked in the"on"position and painted red eDooa 200V 120KYA UPSA 12D(VA UPSA 1 Connect the branch circuit to the line aide of the mein power feed of II YNTH0114ET PNL UDSA BATTERY A the protected promises. i CAOHdEi CABINETSDOOr x Do not power other equipment from the fire alarm branch circuit 150KVA �- -- _ -Run branch circuit wire continuously,without any disconnect 0003 M _XFMR-A - devices,from the power sources to the fire alarm control panel Over-circuit protection for the circuit must comply with article 760 of N 1 C E T " x PNL UDSB 11. the National Electrical Code as well as local codes t2q(VA uPSO t20KVA uPSB 20eV T.All wiring to be complete In accordance with the latest addition of Nathan SchernecK It WITH BYPASS 90,TIERY IOWA all applicable national,provincial,and local codes such as building, NICEf M111032 V CABINET CABINETS R,8 electrical,and ULCS524 Standard for Installation of Fire Alarm � x Fire Alarm Systems,Level IV 'I Systems Special Hazards Systems,Level III ' 1.1 aua aui•. e,:`"'c, elk: Rua �.`.i: „"w' 'wac. 8,The total resistance of the communication loop pair cannot exceed 60 Ohms. W Approvedua m A100ABUSWpY 8.Communication loop circuit(SLC)shall be twlsted-unshielded it 13 Approved As Conectee l� O Revise And Resubmit E W' CO�R 0 E1 SCREEN 8 limited energy cable enclosed In emt conduit Cl For Your Information And Use 10.For detectors shall be mounted a minimum 36"from air supply LI I—pi b"n,l outlet or 24"from air exhaust outlet.A clear space of at least 24"shall i d be maintained In the calling below and around the detector eD0D1 "I tiro ] 1 eDooe 11.Clear space shall be maintained in front of the control unit equal to jA sloe° V _�9 the width of the door or to a minimum of 4O"to provide room for i PNL GRA MINI P(YAtR FIRE ALARM maintenance and testing. N)a10 ® 49N FQV ZONE SECUIUIY CONTROL NOVEL ® %1 12,Alarm,trouble,and supervisory relay contacts-dry form-C rated; srzarws REn--ATE :t� BACKWARD PANEL 1230 2,OA®30VDC(resistive),O.SA @ 30VDC(resistivs) s I MOs7OelAllOt� -/L� Male AN Moir• o P 13.Refer to notlfier SLC wiring manual,document#51253 for ,.__� 'f.'ll_:iiJir.l:7:!!.':l.il.l.'71lNrVrf:�. .• - •J� Ca - -- - — — - — — - additional information. M0a1 1.1 SCALE 1I4"eIV-0" nwm MERIDIAN A.R Z .0 0- -.fit 13.H� PROTECTION cone"P-0 TWA QW4099 LOW CYL DISCH. CONT.HEAD PRESS, PS POSITION 1.oCWY16Y!Mn Oprese — r-- l - - yebDA•Alrf.'AsOar'•iq,• - - - -- j�- Rid DA�—�aM�--N ^'. ,R'. )11R���,,I—� ---�1�--•H N-1 1aNNm lVEBDA'Fhia>te�r dooeda im -x ' - - Mot MDOtiK1004 M000 o004 MOOR Mae? W" 0% OOe MOM AIO11 0004 OWt. 2nsArm M1LSM1 FnSarIaM O.Iacla _ 'x x X December 11,2020 ,/DIM BlInN 1141wa_4albs AlM_gW 'k X.- 7 _MamNAIRM 540m Premed rid Hrol 12VDC AUK POWER IVLPOW SEQUENCE OF OPERATION MATRIX(TO BE REVIEWED BY CLI ENT) i '"— wrP A NCI to r ! ELECTRICAL BOM MIT Mote was Door Dona Meta M016 Door M00g1133� M01V4E9gM012 VVES DEVICE PNe DESCRIPTION pIK AC110N MIA PAUL11 �� NFS-= NotlMrAddressele Control Panel _ 1 W a REFER TO DETAKS W` E 3) Z FSf�51A Proal FleehScan Phdoebal k Detector a � z FOR COwif.Cnf)NS WA S3o0A-6 Intallprit Base,Low profile,flanged a O Ea FDM-1A FlashScen Dual Monitor Module.Class B wiring only 7 Q (I•" n _& FMM-101A _FkmhSwn Miniature Mcn'dor Module_ 1 - V ll Jl K10"� L1 FMM-1A Flseh$can Monitor Module- - 1 �' W © FCM-I-REL Releasing Contrd Module 1 W = Q are I'!)`'-,. l l FRM-1A FlesliScan Relay Module 1 /E/ S a i 1 •y a IIm NBG-12LR Pull Slabon Dual Adlon KL Release 4 Li `O - IFl 15447 MAS-1 Manual Abort,Momentary _ 4 Q O V• (� MB RELRV Service Disconnect Swil h 1 L LL a a- Lis P4RKA Sdedable Hon abobs,Wall,Red,Nksarerproof 2 Z J� (r1) ❑"cl P2RLA•E Seled"Hondstrobe,Wall,Red 3 V • 1 ~•. `" -- _ rxo VLF5W Vasde LaserFodn 500 - _ - 1 W Q /^� O a O O O O — - - J F AvO O O c) (1) v _ V e e tat. W W Mau M�Icb14. 1-$'?l rl .rt 9 �I61.... Q Arkclua�wL 1Frt Dtpc.c--4' - RIeE11 � z AG -. ; I W PJl7_n �7 0 n '�r. W N 12V I MAIN 12V/2eAh -awtvru PIPE LAYOUT (NTS DRAWN BY: KR RISER DETAIL s.r rr ro iw PIPE LAYOUT(NTS) (NTS) DATE: 11/OB/2018 — — — JOB#: XXXXX RISE UP SHEET NO: FP-2 1y •� FIRE SPRINKLER PERMIT APPLICATION ItNIGV Department of Community & Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF COMPLETE AND SCALED PLANS, TWO (2) SETS OF HYDRAULIC CALCULATIONS, TWO (2) SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE SPRINKLER PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION. Type of Permit: ❑✓ New Fire Sprinkler ❑ Fire Sprinkler Add/Alt ❑ Underground Fire Line Project Address: 17601 59TH AVE NE ARLINGTON, WA 98223 Parcel ID #: 31052200400200 Project Valuation: 700.00 Number of Heads: 2 Building Area(Sq Ft): 1,1345 Owner: SNOHOMISH COUNTY PUD NO. 1 Phone Number: NA Address: CLEAN AGENTFIRE Cty:NA State: NA Zip Code: NA Contact Person:NA Phone Number: NA Cell Phone: NA Lira:: NA Address: NA C>ty: NA State: NA Zip Code:NA Contractor: SUPPRESSION SYSTEMS INC. Phone Number: 253-926-3300 Address: 3077 20TH STREETE, SUITE B City: FIFE State: WA ZipCode:98424 Contractor's License Number: S U P P RS 1044RR Expiration: Contact Person: NINA REEVES Email:nina@suppression.com hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accordance with the laws,rules and regulation of the State of Washington. Kev_ee,es=oeo,9eseeoe =ea4�esa�d 10/29/2020 Applicants Signature Date Nina Reeves Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received WEB Forms—131 Page 1 of 1 6116LP Honeywell S�' I Addressable Fire Alarm Control Panels 13 Gffr 6808 Addressable Fire Alarm Control Panel The 6808 is an addressable fire alarm control panel(FACP)that is a direct replacement forthe 5808 FACP.The 6808 can be configured to achieve a point capacity of 198 points.It has one built-in signaling line circuit(SLC),which can support 99 System Sensor'(SK)sensors and 99 SK modules or 127 Hochiki°(SD)devices per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable.A designated panel is configured as the communicator for all panels in the link for convenient single-point communications.It also has a built-in,dual- line POTS and I communicator with additional cellular options available. 6808 The 6808 system can be enhanced by adding modules such as the The supports a variety of devices,including the 6860 remote annunciator which also has four programmable function 6860,5860,and 6855 remote annunciators,5824 buttons to help automate tasks and reduce time spent at the panel. serial parallel printer interface module(for printing system reports),the 5496 NAC expander,5895XL SWIFT°wireless compatibility provides options forwireless detection power module,and SK or SD devices. through a Class A mesh network.It is ideal for hard-to-wire locations, buildings where newwiring is not allowed,or to provide an easy install fire system for new construction projects.SWIFT devices can be combined with other hard-wired 6808 compatible devices. The 6808 also has a form-C trouble relay,two programmable form-C relays,along with powerful features such as drift compensation,pre- trouble maintenance alert,a built-in sensortestto complywith NFPA 72 calibration testing requirements,and calibration trouble alert. FEATURES & BENEFITS • Capable of providing • Convenient • 6860 annunciatorwith Programmable date 125 software zones up to 198 points to field-upgradeable a 4 x 40 large display setting for automatic and 125 output satisfy smaller firmware . Four user- and convenient groups for flexible installation needs . Built-in dual path programmable buttons Daylight Saving Time design options • Connect up to 17 POTS and IP minimize time spent changes panels on one site with communications with executing complex or JumpStart°auto convenient single- optional cellular routine tasks programming reduces point access using the models available for Built-in USB interface installation time SK-NIC Network reliable backup for convenient and Interface Card. reporting Connected panels can quick programming have mixed compatible FACP models SIGNAL LINE CIRCUIT(SLC) PROGRAMMING ORDERING INFORMATION The 6808 SLC loop supports multiple The 6808 system offers several options 6808:Addressable Fire Alarm device types,maintenance alerts,and a to simplify and speed-up programming. Control Panel.(Red cabinet). built-in sensortestto complywith NFPA JumpStart°auto programming 72 calibration testing requirements. minimizes programming required to start COMPATIBLE ANNUNCIATORS a new system.The built-in keypad,or the 6860:4x40 LCD remote fire INDICATOR LIGHTS 6860,5860 or 6855 remote annunciator(4 lines and up to • General Alarm(Red):Flashes if in annunciators give you on-site access to 160 characters)per system;four alarm;solid when alarm is silenced current system programming. programmable buttons • Supervisory(Yellow):Flashes if a Programming can also be accomplished 5860:4x20 LCD remote fire supervisory condition exists;solid using the Windows°-based Honeywell annunciator.5860 is gray;586OR is red when supervisory is silenced Fire Software Suite(HFSS)program. 6855:4x20 LCD remote fire • System Troubles(Yellow):Flashes annunciator SOFTWARE TOOLS 5865-3 or 5865-4:LED annunciators if a trouble condition exists; SKST.Silent Knight Selection Tool solid when trouble is silenced can display up to 30 LEDs(15 red and provides the installer or design architect 15 yellow).The 5865-4 has key switches • System Silenced(Yellow): with a Windows°software system for silence and reset,and a system On when an alarm,trouble or configuration toolto create a detailed Bill trouble LED. supervisory condition has been of Material(BOM)and battery silenced but not et cleared 5880:LED/10 module has 40 Y calculations. programmable LED outputs and eight • System Power(Green):Flashes HFSS:Honeywell Fire Software Suite supervised dry contact inputs which are forAC failure;solid when provides communication and panel useful for custom applications.You can power systems are normal programming,detector status,event use up to eight 5880 modules on one USER INTERFACE history and additional data.Requires a control panel for maximum flexibility. The 6808 built-in 4x 20 annunciator PC running Microsoft'Windows°. Its compact size allows mounting inside with 80 character LCD display ADDITIONAL INFORMATION the annunciator,or in an accessory and large easy-to-use tactile Twisted-unshielded pair cabinet. touchpad can be used for system wire is recommended. 6808 COMPATIBLE DEVICES AND operation,programming and The 6808 also has 13 preset notification ACCESSORIES maintenance.It has five LEDs for cadence patterns See the data sheets listed below for a complete listing of the SK,SD or SWIFT alarm,supervisory,system trouble, (including ANSI 3.41). devices. system silenced and system power. 53623:SK Devices Data Sheet AGENCY LISTINGS AND APPROVALS 53624:SD Devices Data Sheet System operations include silencing NPFA 13,NFPA 15,NFPA 16,NFPA 70, 350614,350616&350618:SWIFT alarms and troubles,resetting alarms NFPA 72:Central station;remote wireless devices and the display of alarm troubles and Signaling;Local Protective Signaling For a complete and current listing of memory.The system's non-volatile Systems;Auxiliary Protected Premises compatible devices and accessories,visit event history buffer stores 1,000 Unit;Water Deluge releasing service. www.sitentknight.com. Important:You cannot mix SK and SD events for viewing from the built- Suitable for automatic,manual, devices in the same fire alarm system. in or remote annunciator.System waterflow,sprinkler supervisory(DACT operations can be initiated with a non-coded)signaling services mechanicalfirefighter's key or a • UL Listed:S2766 valid 4-to 7-digit operator's code. • CSFM:7165-0559:0502 • FDNY:COA#6246 • FM approved Page 2 of 4—351608:13 9/26/2018 SK COMPATIBLE ADDRESSABLE B200S-LF(-IV,-WH):Low-Frequency WSK-WGI:Wireless Gateway DEVICES intelligent sounder base WSK-PHOTO:Wireless Photoelectric smoke SK-ACCLIMATE:Multi criteria B20OS-LF:Low-frequency intelligent detector photoelectric smoke detectorwith thermal sounder base WSK-PHOTO-T.Wireless Multi-criteria 135°F fixed temperature 13224RB(-IV,-WH):Relay base photoelectric smoke detectorwith thermal SK-BEAM:Reflected beam smoke detector B224RB: Relay base detection(135°F fixed temperature)and without test feature B224131(-IV,-WH):Isolator base 3510W 4"base SK-BEAM-T:Reflected beam smoke B224B1: Isolator base WSK-HEAT:Wireless Heat,(135°Ffixed detectorwith testfeature temperature)and B51OW 4"base SK-CONTROL:Supervised control module SD COMPATIBLE ADDRESSABLE WSK-HEAT-ROR:Wireless heat,POP SK-CONTROL-6:Six circuit supervised DEVICES (135°F fixed temperature)and B510W 4" control module SD505-6AB:Addressable 6"base base SK-DUCT:Photoelectric duct smoke SD505-6113:Addressable 6"short circuit WSK-MONITOR:Wireless monitor module detector with extended airspeed range isolator base WSK-RELAY:Wireless relay module SK-FIRE-CO:Four criteria fire and carbon SD505-6RB:Addressable 6"relay base W-USB:SWIFT Tools USB transceiver used monoxide detector SD505-6SB:Addressable 6"sounder base for communication with SWIFT devices SK-HEAT:Fixed thermal detector(135°F) SD500-AIM:Addressable input module SK-H EAT-W:Fixed thermal detector (switch input) SBUSACCESSORIES (135°F),white SD500-ANM:Addressable notification 5496:A 6 amp notification power expander SK-HEAT-ROR:Fixed rate of rise detector module with four power-limited notification (135°F) SD500-ARM: Addressable relay module appliance circuit outputs. SK-HEAT-ROR-W:Fixed rate of rise SD505-DTS-K: Remote test switch and 5883:Relay Interface.Provides 10 Form C detector(135°F),white LED indicator for theSD505-DUCTR relays. SK-HEAT-HT:Fixed high temperature SD505-DUCT:Addressable Duct Smoke 5824:Serial/Parallel Printer Interface thermal detector(190°F) Detector. Module for printer connection. SK-HEAT-HT-W:Fixed high temperature SD505-DUCTR:Addressable Duct 5895XL:PowerSupplywith six Flexput- thermal detector(190°F),white Detector housing with relay base. circuits,and two Form C relays.Max.16 per SK-ISO:Fault isolator module system. SD505-H EAT:Absolute temperature heat SK-MINIMON:Mini monitor module detector.Trip point rangefrom 5815RMK:Remote mounting kit. SK-MONITOR:Monitor module 1350E-150°F(0°C-37°C). Dimensions:10 3/8"W x 10-3/16°H x 3"D SK-MONITOR-2:Dual input monitor SD500-LIM:Addressable Line isolator COMMUNICATION OPTIONS module module SK-MON-10:10 input monitor module SD500-MIM:Addressable Mini input CELL-CAB-SK:Cellular communicator, SK-PHOTO:Photoelectric smoke detector monitor module(switch input) metal enclosure with lock/key SK-PHOTO-W:Photoelectric smoke SD505-PHOTO:Photoelectric smoke CELL-MOD:Cellular communicator,plastic detector,white detector enclosure SK-PHOTO-T.Photoelectric smoke detector SD500-PS/-PSDA:Addressable Single or *Sole path,powered by panel. with thermal(135°F fixed temperature) dual action pull station IPGSM-4G:Dual path fire alarm SK-PHOTO-T-W:Photoelectric smoke SD500-SDM:Addressable smoke detector communicator,cellular and/or I (primary or backup,selectable) detector with thermal(135°Ffixed module temperature),white SK-I13-2:Remote reporting via the Internet. SK-PHOTOR:Photoelectric detector with AUDIBLE/VISIBLE DEVICES Requires a VisorAlarm°receiver at the central remote test capability These AV devices are all 2-wire.Color:"R" station SK-PHOTO-R-W:Photoelectric detector indicates red;"W"denotes white.For a MISC.ACCESSORIES with remote test capability,white complete listing of Silent Knight AV devices SK-NIC:Network Interface Card.Provides a SK-PULL-SA:Addressable single action go to www.sitentknight.com. common communications link for the 6808. pull station CHSRL/CHSWL:Wall chime/strobe SK-PULL-DA:Addressable dual action pull SK-NIC-KIT:Installation Accessory Kit station p CHSCRL/CHSCWL:Ceiling chime/strobe SK-FML:Fiber-Optic Multi Mode, CHRL/CHWL:Wall chime transmitter and receiver SK-RELAY:Addressable relay module HRL/HWL:Wall horn SK-FSL:Fiber-Optic Single Mode SK-RELAY-6:Addressable Six relay control P2RL/P2WL:Wall horn/strobe module RBB:Remote battery box accessory cabinet PC2RL/PC2WL:Ceiling horn/strobe for batteries that are too large to fit in the relay/monitor module Dual Addressable YMON S SRL/SWL:Wall strobe FACP cabinet.Dimensions:16"W x 10"H x SK-ZONE:Addressable zone interface SCRL/SCWL:Ceiling strobe 6"D(406mm W x 254mm H x 152mm D). module SPSCRL/SPSCWL:Ceiling speaker/strobe SK-SCK:Seismic Compliance Kit used to SK-ZONE-6:Six zone interface module SPSRL/SPSWL:Wall speaker/strobe securely fasten batteries to the fire panel. B300-6(-IV):6"base for SK-W Series SPRL/SPWL:Wall speaker B21OLP:6"mounting base SPCRL/SPCWL:Ceiling speaker B501(-13L,-IV,-WHITE):4"flangeless base B501:4"Flangeless mounting base SWIFT WIRELESS DEVICES B200S(-IV,-WH):Intelligent sounder base SWIFT is only compatible with System B20OS:Intelligent sounder base Sensor(SK)devices.It is not compatible with Hochiki(SD)devices. Page 3 of 4—351608:13 9/26/2018 6808 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS(NACs) Flexput®,Honeywell', Overall Dimensions:16.36"W x 26.37"H x 3.91"D Four programmable circuits which can be JumpStart°,Silent Knight°, Shipping Weight: programmed individually as: SWIFToandSystem pp 9 9 Sensor`are registered Color:Red NACs:3A @ 27.4VDC per circuit,power-limited trademarks of Honeywell (with a maximum current of 6A) International Inc. ENVIRONMENTAL Auxiliary Power Circuits:3A @ 27.4VDC per circuit, power-limited Hochiki®is a registered Operating Temperature:320 F to 1200 F (01 C to trademark of Hochiki 49°C) Corporation.Microsoft' Humidity:0 to 93%relative humidity(non- Supports Class B(Style 4)and Class A(Style 6 or 7) and Windows°are condensing) configuration for the SLC registered trademarks of Microsoft Corporation. ELECTRICAL WIRING:See the product manual for wiring details This document is not 6808 Primary AC:120 VAC C 60Hz,3.3A Total intended to be used for Accessory Load:6A @ 27.4VDC power-limited installation purposes.We S try to keep our product Standby Current:190mA information up-to Alarm Current:250mA date and accurate.We Battery Charging Capacity:7 to 35AH cannot cover all specific Battery Size:7AH to 18AH max.allowed in control applications or anticipate panel cabinet.Larger capacity batteries can be all requirements.All specifications are subject housed in RBB accessory cabinet. to change without notice. For Technical Support,call 800-446-6444. Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 SILENT' ©201 800-328-0103 9) 8 e osi18 ®ICI= 201 8 Honeywell International Inc. aes-corp.com of SECURITY CORPORATION INNOVATION 7707 Fire Subscribers IntelliNet A Newer, Smarter Alarm Communications Platform Feature Highlights i • Leverages state of the art technology • Applies advanced security protection • Offers flexible power and configuration options �L • Engineered for backward compatibility with legacy systems NFPA LISTED • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Includes robust Multiple Communication Technologies(MCT)feature • Emulates virtual keypad • Improves functionality with an adaptive Graphic User Interface (GUI)for programming via smartphones,tablets and PCs • Plus many more... Key Benefits • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password-protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP)without requiring an electrician onsite and without Subscriber backup battery; (2) Directly from the FACP with Subscriber backup battery; or (3)Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option,they are the ideal drop-in replacement for Plain Old Telephone Service (POTS) lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status. The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or having to use a handheld programmer.Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network D)Burglary D _ Subscriber ----'--------- / 1 1 C B)Fire / / ` Subscriber / _ AES-Network Management System B ———————————— Primary AES-Mul[iNe[Receiver � I A)Alarm Panel Secondary AES-MUIt Net Receiver / � I 0 :C Alarm Automation p ———-_— --- C)IPLinks Customer Location I Mesh Radio Technology I Central Monitoring Station Alarm Panel&AES Subscriber Multi-path AES-IntelliNet@ Network Primary&Secondary AES-MultiNet System sends critical event signal delivers alarm signals via smart routing receives transmission in 1-3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add-on accessory board. AES subscribers' intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming.A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units.A FACP Power Supply Adapter is required for certain configurations when using flexible power options. The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: aes-corp.com/products/fire/fire-marshal-resources How to Order 7707 Fire InteffiNet 2.0 Fire Subscribers 2.0 PREMIUM (UL& ULC Listed) 7707P-88-M IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber, 4x4 Zone(4 Reversing Polarity,4 Supervised)with Multiple Communication Technologies(MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 4x4 Zone(4 Reversing Polarity,4 Supervised) 7707P-44-ULP-M with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 2.0 ACCESSORIES 7794A Standalone AES-IntelliPro Fire full data module add-on accessory board with firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy . • - 7706-ULF Integrated Fire Monitoring System, Red Enclosure 7788F-ULP-P Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro(7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7788F-ULP Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure 7744F-ULP-P Legacy Fire Subscriber,4 Zone with 7795 AES-IntelliPro(7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7744F-ULP Legacy Fire Subscriber,4x4 Zone,4 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7744F Legacy Fire Subscriber,4x4 Zone,4 Reversing Polarity,4 Supervised Zones, Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add-on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version Technical Specifications 7707 Fire DIMENSIONS ALARM SIGNAL INPUTS/ZONES PORTS 13"H x 8.5"W x 4.5"D 8 individually programmable Ethernet for configuration (33cmH x 21.5cmW x 11.4cmD) E.O.L.type zone inputs and message communication 4+4:4 reverse polarity input and USB access for software upgrade WEIGHT 4 individually programmable 5.8 lbs(2.6 kilograms) E.O.L.type zone inputs REMOTE ANNUNCIATOR excluding battery Optional 7794A AES-IntelliPro for AES Model 7740 13 Ibs(5.9 kilograms)with full data via Contact ID, Pulse, Remote Annunciator, supervised 10 Ah battery Modem Ile and Modem IIla2 COMPATIBLE RECEIVERS RADIO FREQUENCY UL LISTINGS 7705i AES-MultiNet Receiver Standard Frequency Range: UL 864 loth Edition 450-470MHz Standard for Control Units and CONFIGURATION INTERFACE Contact AES for other UHF Accessories for Fire Alarm Systems Web browser capable device and VHF frequencies ULC S559-04 1st Edition accessible via smartphone,tablet, Equipment for Fire Signal laptop, or PC ANTENNA Receiving Centres and Systems 2.5dB tamper resistant antenna CURRENT CONSUMPTION included, mounts on enclosure Standby w/charged backup battery: Optional remote mounting TROUBLE OUTPUT—ACK 200 mA(1.2 A Transmitting) antenna available DELAY/ANTENNA CUT Standby+ charging backup battery: Form C relay,fail secure, rated 24V 900 mA(1.9 A Transmitting- MAX) POWER INPUT DC 1A resistive, unsupervised AC SOURCES POWER OUTPUT Transformer: Class 2 RESET BUTTON 2 or 5 Watts 16.5V AC nominal output Located on main circuit board Factory set 1.9 A max current(40 VA MIN) ELK ELK-TRG1640, OPERATING TEMPERATURE ENCLOSURE MATERIAL MG ELECTRONIC SALES MGT1640, 32 to 120°F(0 to 49°C) Steel with paint finish or AES 1640(not included) DC SOURCES(includes FACP) STORAGE TEMPERATURE FINISH COLOR 24V DC Regulated Power Supply 14 to 140°F(-10 to 60oC) Red with Subscriber Rechargeable Battery RELATIVE HUMIDITY VISUAL INDICATORS 1.9 A max current 0 to 93%, non-condensing Front panel LCD (2 x 20 alphanumeric character BACKUP BATTERY RECHARGE CAPABILITY backlit display) 10-12 Ah, UL recognized lead acid Will charge 12V battery size Power and Trouble LEDs gel cell, size based on subscriber from 10-12 Ah (ALM,Trouble,Tx, Rx,WA) configuration Contact Us For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. f in 0 v o www.aes-corp.com AES Corporation 1 285 Ne • Peabody, MA 01960 United States O Copyright 2018AES • •• • • S are registered trademarks of AES Corporation Honeywell ®SILENT' KNIGHT 6860 Remote Annunciator The 6860 remote annunciator can be used to view system status indicators for Honeywell Silent Knight fire alarm control panels(FACPs)from anywhere within the system.It provides a convenient wayto view system status indicators. The 6860 comes in a locked,key controlled cabinet-combining security with easy access.It does not require a code or firefighter's key to silence or reset a panel,and also has convenient separate scroll buttons for alarm, supervisory and trouble conditions.The remote annunciator communicates with the main fire alarm control panel through an PS-485 connection. The 6860 has a large 160 character,4 x 40 display and four programmable buttons.These features provide more options for set-up and operation when compared to similar remote annunciators. 6860 The 6860 can be surface or flush mounted.The RA-100TR trim ring can be used for surface mounts. COMPATIBILITY The 6860 is compatible with the following Honeywell Silent Knight FACPs: • 6820:Addressable fire alarm control panelwith up to 1,110 addressable points • 6820EVS:Addressable fire alarm control panel with an emergencyvoice system,up to 1,110 addressable points • 6808:Addressable fire alarm control panel with up to 198 addressable points • 6700:Addressable fire alarm control panel with up to 100 addressable points FEATURES & BENEFITS • Four line LCD display • Easily view current Five status LEDs make • System access Four programmable with 40 characters per status by alarms, it easier to monitor through a user code or function keys for for line;160 characters supervisories,or and respond to status firefighter's key improved efficiencies provides ample space troubles changes.They include: . Support for and time-savings; for communicating Alarm,Supervisory, frees-up time spent at • On-board piezo simultaneous use of operating messages sounder audibly Silence and AC Power multiple 6860s the panel • Larger keypad buttons indicates alarms, indicators. • Can be flush or Comfortable tactical makes it easier to troubles,and • Accommodates wiring surface mounted.Trim feel and clear audible maneuver for system supervisories lengths up to 6000 ft. ring available for confirmation supports reset and silencing Uses the RS-485 from the control panel surface mounting. accurate • Initiate and end fire SBUS to interface with for added design and programming and drills with a single key the panel install flexibility easy operation press 6860 Technical Specifications Review Events For a complete listing of all Individually by Alarms, Supervisories,or Troubles 160 Character compliance approvals and Display certifications,please visit www.sitentknight.com. LED Status Indicators Microsoft,Windows,and the Windows Logo are registered trademarks or trademarks of Large Buttons for Microsoft Corporation. System Silence,Reset, Event Acknowledge, Silent Knight and and Fire Drill Honeywell'are registered trademarks of Honeywell ® o International,Inc. m ° ° This document is not la ° intended to be used for ° Ergonomic installation purposes.We m Designed Keypad (Hidden when door is closed) try to keep our product information up-to date and accurate.We cannot cover all specific applications or anticipate Numeric Keypad all requirements.All (Hidden when door is closed) specifications are subject Four Programmable to change without notice. Function Keys For Technical Support, 6860 FEATURES call800-446-6444. PHYSICAL ORDERING INFORMATION Flush Mount 6860:Remote Annunciator.Four line(4x40)LCD Outside wall:12.25"W x 11.5"H x 7/8"D(31.1W x annunciator.Red 29.2H x 2.2D cm) Inside wall:9-3/8"W x 8-3/8°H x 2"D(23.8W x ACCESSORIES 21.3H x 5.1D cm) RA-100TR:Red surface mount trim ring Surface Mount:(Including Trim Ring)12.25"W x 11.5"H x 3"D(31.1W x 29.2H x 2.2D cm) AGENCY LISTINGS AND APPROVALS UL listed ENVIRONMENTAL CSFM#7165-0559:0500 Operating Temperature:321Fto 1201F (0°C to NFPA 72 49°C) FM approved Humidity:0 to 93%relative humidity(non- FDNY COA approved condensing) ELECTRICAL Operating Voltage:24VDC Standby Current:25mA Alarm Current:50mA For more information Learn more about Silent Knight's 6860 and other products available by visiting www.SitentKnight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT06472-1610 800.328.0103 3516121 Al 11/17 SILFN www.honeywell.com ©2017 Honeywell International Inc. LUSUGHT Honeywell ®SILENT' KNIGHT SK-HEAT-W Series Intelligent Thermal (Heat) Detector Honeywell Silent KnightSK-HEAT-W Series intelligent thermaIdetectors are designed for both performance and aesthetics.A new modern,sleek, contemporary design and advanced thermal technologies make the SK-HEAT-W Series ideal for both system operation and building design. The point ID address,set using rotary decimal switches,provide specific detector locations.The series includes a 1351F/571C fixed temperature, rate-of-rise and a 1901F/881C fixed high-temperature detectors.These thermal detectors provide effective,intelligent property protection in a variety of applications. SK-HEAT-W FEATURES & BENEFITS • Sleek and stylish • High temperature 360°-field viewing • Built-in functional test • Sealed against back contemporary design model(SK-H EAT- angle of the visual switch activated by pressure • Advanced thermal W-HT)factory preset alarm indicators(two external magnet . plugs into separate technology for fast to190°F(88°C) bi-color LEDs).LEDs . Walk test with address base for ease of response • Addressable by device blink green in Normal display(an address of installation and condition and turn on 121 will blinkthe maintenance • Fixed temperature • Two-wire SLC steady red in Alarm. model(SK-HEAT-W) connection detector LED 12- . SEMS screws for • Integral (pause)-1) factory preset to . Visible LEDs"blink" wiring of the separate 135°F(570C) communications and . Low standby current base every time the unit is built-in device-type • Rate-of-rise model addressed identification • Designed for • Optional remote, (SK-HEAT-W-ROR), . Built-in tamper- directsurface or single-gang LED 150F(8.3°C)per p Remote test feature electrical box accessory resistant feature from the panel minute mounting APPLICATIONS INTELLIGENT BASES ACCESSORIES Use thermal detectors for protection of B300-6:White,standard flanged CK300:Color Kit(includes cover and property.For further information,refer low-profile mounting base. trim ring),white,l0-Pack. to manual 156-6541,Applications B300-6-BP:Bulk pack of 3300-6, CK300-IV: Color Kit(includes cover Manual for System Smoke Detectors, package contains 10. and trim ring),ivory,10-Pack. which provides detailed information on B300-6-IV:Ivory,standard flanged CK300-BL:Color Kit(includes cover detector spacing,placement,zoning, low-profile mounting base. and trim ring),black,l0-Pack. wiring,and special applications B30OA-6-IV:Ivory,standard flanged M02-04-01:Detector test magnet. INSTALLATION low-profile mounting base.UL listed. M02-09-00:Telescoping test magnet. 6501-WHITE:White,standard RA10OZ:Remote LED annunciator The SK-HEAT-W Series plug-in European flangeless mounting base.UL intelligent thermal detectors use a SMB600:Surface Mounting Kit separate base to simplify installation, listed. (flanged). service,and maintenance.Installation B501-BL:Black,standard European TR300:Replacement trim ring for instructions are shipped with each flangeless mounting base.UL listed. B300-6,white. detector B501-IV:Ivory,standard European TR300-IV:Replacementtrimring for flangeless mounting base.UL listed. B300-6-IV,ivory.. Mount base(all base types)on an B20OS-WH:White,Intelligent, electrical backbox which is at least 1.5" programmable sounder base. (3.81 cm)deep. B20OS-IV:Ivory,Intelligent, programmable sounder base. NOTE: 6200SR-WH:White,Intelligent sounder •Because of the inherent supervision base for retrofit applications. provided by the SLC loop,end-of-line B200SR-IV:Ivory,Intelligent sounder resistors are not required.Wiring base for retrofit applications. "T-taps"or branches are permitted for Style 4(Class"B")wiring. B20OS-LF-WH:White,Low Frequency Intelligent,programmable sounder •When using relay or sounder bases, base. consult the installation sheet for device B20OS-LF-IV:Ivory,Low Frequency limitations between isolator modules Intelligent,programmable sounder and isolator bases. base. NOTE:Detectors must be mounted to one B200SR-LF-WH:White,Low of the Intelligent Bases listed below. Frequency Intelligent sounder base for ORDERING INFORMATION retrofit applications. SK-HEAT-W:Thermal heat detector, B200SR-LF-IV:Ivory,Low Frequency 135°F fixed,white. Intelligent sounder base for retrofit SK-HEAT-ROR-W:Thermal heat applications. detector,1350F rate of rise,white. B224RB-WH:White,plug-in System SK-HEAT-HT-W:Thermal heat detector, Sensor relay base. 190°F high temp,white. B224RB-IV:Ivory,plug-in System Sensor relay base. B224BI-WH:White,plug-in System Sensor isolator detector base. B224BI-IV:Ivory,plug-in System Sensor isolator detector base. SK-HEAT-W Series Detector Technical Specifications PHYSICAL COMPATIBILITY Fora complete listing of all compliance approvals and Height:2.0"(51mm)installed in B300-6 base The SK-HEAT-W series detectors are certifications,please visit Diameter:6.2"(156mm)installed in B300-6 compatible with the following Honeywell Silent ww.sitentknight.com. base 4.1"(104 mm)installed in B501 base Knight fire alarm control panels: Microsoft,Windows,and the Windows Logo are Weight:3.4 oz(95 g) 6820:Addressable fire alarm control panel registered trademarks 6820EVS:Addressable fire alarm control panel or trademarks of ENVIRONMENTAL Microsoft Corporation. with an emergency voice system. Operating Temperature range: Silent Knight°,System 6808:Addressable fire alarm control panel Sensor'and Honeywell' Heat-Fixed temperature:-4°F to 100°F(-20°C are registered to 38°C) 6700:Addressable fire alarm control panel trademarks of Honeywell International,Inc. Heat-Rate of Rise(ROR):-4°F to 100°F(-20°C 5700:Addressable fire alarm control panel ° 5808:Addressable fire alarm control panel This document is not to 38 C) intended to be used for Heat-High Temperature:-4°F to 150°F(-20°C 5820XL:Addressable fire alarm control panel installation purposes.We 9 p tryto keep our product to 66°C) 5820XL-EVS:Addressable fire alarm control information up-to panel with an emergency voices stem date and accurate.We Humidity:10%to 93%non-condensing p g y y cannotcover all specific applications or anticipate Thermal Ratings:Fixed Temperature Set point: AGENCY LISTINGS AND APPROVALS all requirements.All 1350F(57°C) For exact certification listings for each model, specifications are subject please reference the respective agency Web site. to change without notice. Rate-of-Rise Detection:151F/min.(8.31C/min UL listed:S2101 For Technical Sup port, High Temperature Heat:190°F(881C)Electrical FM Approved call800-446-6444. Ratings CSFM:7270-0559:0511 ELECTRICAL RATINGS Voltage Range:15 to 32VDC peak Standby current(max.avg.):200uA C 24 VDC (one communication every 5 seconds with LED enabled). LED current(max.):4.5mA @ 24 VDC("ON"). For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell N o rthfo rd,CT 06472 Doc 351637 1 Rev A 104/18 SILENT' 800-328-0103 ©2018 Honeywell International Inc. 0 KNIGHT Honeywell ®SILENT' KNIGHT SK-MONITOR Intelligent Monitor Module The SK-MONITOPis an addressable monitor module for use with Honeywell Silent Knight Series fire alarm control panels(FACPs).The SK-MONITOR is intended for use in intelligent,two-wire systems,where individual address of each module is selected using the built-in rotary switches. The SK-MONITOR supports Class A supervised or Class B su ervised P P p P wiring to the load device.Conventional4-wire smoke detectors can be `'` monitored for alarm and trouble conditions. INSTALLATION The SK-MONITOR mounts directly into a 4"square electrical box.The box must have a minimum depth of 2-1/8".A surface mount electrical box (System Sensor'PN SMB500)is available from Silent Knight. SK-MONITOR FEATURES & BENEFITS • Single contact monitor Panel controlled • UL Listed • Support for Class A status LED that . Rotary address and Class B wiring flashes green in switches for fast normal state and is installation • Fully supervised solid red in alarm • SEMS screws for easy wiring SK-MONITOR Technical Specifications For a complete listing of all compliance approvals and certifications,please visit PHYSICAL ORDERING INFORMATION www.sitentknight.com. Height:4.5"H x 4"W x 1.25"D(11.4 X 10.2 X 3cm) SK-MONITOR:Monitor Module Microsoft,Windows,and Shipping Weight:6.3 oz(196 g) ACCESSORIES. the Windows Logo are registered trademarks ELECTRICAL SMB500:4"Square surface mount electrical box or trademarks of Operating Voltage:15—32VDC Microsoft Corporation. Current Draw(LED on):5.OmA max COMPATIBILITY The SK-MONITOR i compatible with the Silent Knight ,System Operating Current(LED flashing):375µ e s comA p Sensor'and Honeywell' Standby Current:400 µA max @ 24 VDC(one following Honeywell Silent Knight fire alarm are registered communication every 5 sec with 47K EOL);550µA control panels: trademarks of Honeywell max @ 24 VDC(one communication every 5 sec 6820:Addressable fire alarm control panel International,Inc. with EOL<1K) 6820EVS:Addressable fire alarm control panel This document is not 5.5 mA(with LED latched on) with an emergency mass notification system. intended to be used for LED Current:5.5 mA(with LED latched on) 6808:Addressable fire alarm control panel installation purposes.We End-of-Line Resistance:47KS2 6700:Addressable fire alarm control panel tryto keep our product information up-to Initiating Device Circuit Wiring Resistance:1,500 5700:Addressable fire alarm control panel date and accurate.We 0max 5808:Addressable fire alarm control panel cannot cover all specific SLC Loop Resistance:4092 max. 5820XL:Addressable fire alarm control panel applications or anticipate all requirements.All 5820XL-EVS:Addressable fire alarm control panel specifications are subject ENVIRONMENTAL with an emergency mass notification system Operating Temperature:320F—120OF(O°C— g y to change without notice. 49°C) For Technical Support, Humidity:10%—93%non-condensing call800-446-6444. For more information Learn more about Honeywell Silent Knight and other products byvisiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT06472 Doc 3501311 Rev G 111/17 SILENT' 800-328-0103 ©2017 Honeywell International Inc. ®KNIGHT Honeywell ®SILENT' IQVIGHT SK-PULL-SA / SK-PULL-DA Intelligent Pull Stations The SK-PULL-SA is a single action pull station requiring only one motion to . activate the station.The SK-PULL-DA is a dual action pull station requiring two motions to active the station.The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel(FACP). PULL DOWN Extremely easy to operate,the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating a fire alarm signal.The FACP recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. INSTALLATION The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-1/0 SK-PULL-SA surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13°(5.40 cm)or double gang or 4°(10.61 cm)square electrical box.You can also use the optional(System Sensor'PN BG-TR) trim ring if the station is being semi-flush mounted. , PUSH IN PPUSH IN ULL�• WNI i SK-PULL-DA FEATURES & BENEFITS • Installer can open • Key operated test and Meets the Americans • Reliable analog Handle latches in station without reset lock using lock with Disabilities Act communications for down position and the causing an alarm plate actuator Accessibility trouble-free operation word Activated condition y Guidelines(ADAAG) appears,clearly • Key matches • Braille text on station • Dual-color LED is compatible FACP controls and operating handle indicating the station visible through handle locks mechanisms has been pulled guidelines(Section • Rotary address of station blinks green . Meets ADA 4.1.3[13]) switches for fast UL Listed,including to indicate normal UL 38,Standard of operation and remains requirement for 5 lbs • Shell,door,and handle installation Manually Actuated maximum pull force to steady red in an alarm active molded from durable Signaling System condition LEXAN° • CSFM Listed • MEA Listed SK-PULL-SA / SK-PULL-DA Technical Specifications For a complete listing of all compliance approvals and certifications,please visit PHYSICAL ORDERING INFORMATION www.sitentknight.com. Dimensions:5.5"H x 4"W x 1.45"D(14 x 10.2 x SK-Pull-SA:Single Action Pull Station 3.7cm) SK-Pull-DA:Dual Action Pull Station Microsoft,Windows,and HousingMaterial:LEXAN of carbonate resin the Windows Logo are p Y registered trademarks Bi-Colored LED: ACCESSORIES or trademarks of Blinking Green:Normal BG-TR:Optional trim ring. Microsoft Corporation. Steady Red:Alarm SB-1/0:Surface backbox,indoor/outdoor. Silent Knight®,System Switch:Single pole,single throw(SPST)normally *Unless otherwise noted,specifications apply to Sensor'and Honeywell' open(N/O)switch which closes upon activation of SK-Pull-SA and SK-Pull-DA are registered the pull station trademarks of Honeywell COMPATIBILITY International,Inc. ELECTRICAL The SK-PULL-SA AND SK-PULL-DA are This document is not Operating Voltage:15—32VDC compatible with the following Honeywell Silent intended to be used for SLC Standby and Alarm Current:350µA Knight fire alarm control panels: installation purposes.We Wire Gauge:Up to 12AWG(3.1 mmz) 6820:Addressable fire alarm control panel tryto keep our productinformation up-to 682OEVS:Addressable fire alarm control panel date and accurate.We ENVIRONMENTAL with an emergency voice system. cannot cover all specific Operating Temperature:320F—120°F(0°C— 6808:Addressable fire alarm control panel applications or anticipate 49°C) 6700:Addressable fire alarm control panel all requirements.All specifications are subject Humidity:10%—93%non-condensing 5700:Addressable fire alarm control panel to change without notice. 5808:Addressable fire alarm control panel 5820XL:Addressable fire alarm control panel call80 -446 6444. ca11800-446-6444. 5820XL-EVS:Addressable fire alarm control panel with an emergency voice system For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 Doc 350135 1 Rev E 1 11/17 SILENT' 800-328-0103 ©2017 Honeywell International Inc. ®KNIGHT Honeywell ®SILENT' KNIGHT SK-PHOTO-W Series Intelligent Plug-In Photoelectric Smoke Detector Honeywell Silent Knight SK-PHOTO-W Series plug-in smoke detectors are designed for both performance and aesthetics.A new modern,sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software.Sensitivity is continuously monitored and reported to the panel.Point ID capability allows each detector's address to be set with rotary,decimal address switches,providing exact detector location for selective maintenance when chamber contamination reaches an - unacceptable level. Dual electronic thermistors add 135°F(57°C)fixed temperature thermal sensing on the SK-PHOTO-T-W.The SK-PHOTO-R-W is a remote test SK-PHOTO-W capable detector for use with DNR Series duct detector housings. FEATURES & BENEFITS • New modern profile for • Dual LED design • Expanded color • Optional relay, improved aesthetics provides 360°viewing options isolator,and sounder • Stable communication angle . SEMS screws for bases technique with noise • Remote test feature wiring of the separate • Plugs into separate immunity from the panel base base for ease of • Low standby current • Built-in functional test installation and • Two-wire SLC switch activated by maintenance connection external magnet • Optional remote, • Built-in tamper- single-gang LED resistant feature accessory • Sealed against back pressure DETECTOR SPACING AND INTELLIGENT BASES ACCESSORIES APPLICATIONS B300-6:White,standard flanged CK300:Color Kit(includes cover and Honeywell recommends spacing low-profile mounting base. trim ring),white,10-Pack. detectors in compliance with NFPA 72. B300-6-BP:Bulk pack of 3300-6, CK300-IV: Color Kit(includes cover In low airflow applications with smooth package contains 10. and trim ring),ivory,10-Pack. ceiling,space detectors 30 feet(9m). B300-6-IV:Ivory,standard flanged CK300-BL:Color Kit(includes cover For specific information regarding low-profile mounting base. and trim ring),black,10-Pack. detector spacing,placement,and B501-WHITE:White,standard M02-04-01:Detector test magnet. special applications referto NFPA 72. European flan eless mounting base.UL p g g M02-09-00:Telescoping test magnet. System Smoke Detector Application listed. RA100Z:Remote LED annunciator Guide,documentA05-1003,is available B501-BL:Black,standard European SMB600:Surface Mounting Kit at systemsensor.com flangeless mounting base.UL listed. (flanged). INSTALLATION B501-IV:Ivory,standard European TR300:Replacement trim ring for The SK-PHOTO-W Series flangeless mounting base.UL listed. B300-6,white. plug-in detectors use a separate base to B20OS-WH:White,Intelligent, TR300-IV:Replacementtrimring for simplify installation,service,and programmable sounder base. B300-6-IV,ivory. maintenance. Installation instructions B20OS-IV:Ivory,Intelligent, are shipped with each detector. programmable sounder base. B200SR-WH:White,Intelligent sounder Mount base(all base types)on an base for retrofit applications. electrical backbox which is at least 1.5" 6200SR-IV:Ivory,Intelligent sounder (3.81 cm)deep. base for retrofit applications. NOTE: B20OS-LF-WH:White,Low Frequency •Because of the inherent supervision Intelligent,programmable sounder base. provided by the SLC loop,end-of-line resistors are not required.Wiring B200S-LF-IV:Ivory,Low Frequency "T-taps"or branches are permitted for Intelligent,programmable sounder Style 4(Class"B")wiring. base. B200SR-LF-WH:White,Low •When using relay or sounder bases, Frequency Intelligent sounder base for consult the installation sheet for device retrofit applications. limitations between isolator modules B200SR-LF-IV:Ivory,Low Frequency and isolator bases. Intelligent sounder base for retrofit applications. ORDERING INFORMATION B224RB-WH:White,plug-in System SK-PHOTO-W:Photoelectric smoke Sensor relay base. detector,white. B224RB-IV:Ivory,plug-in System SK-PHOTO-R-W:Photoelectric smoke Sensor relay base. detector,remote test capable,for use B224BI-WH:White,plug-in System with DNR(W)duct smoke detectors, Sensor isolator detector base. white. B224BI-IV:Ivory,plug-in System SK-PHOTO-T-W:Photoelectric smoke Sensor isolator detector base. detector with thermal sensing,white. SK-PHOTO-W Series Detector Technical Specifications PHYSICAL COMPATIBILITY Fora complete listing of all compliance approvals and Height:2.0"(51mm)installed in B300-6 base The SK-PHOTO-W series detectors are certifications,please visit Diameter:6.2"(156mm)installed in B300-6 compatible with the following Honeywell Silent www.sitentknight.com. base 4.1"(104 mm)installed in B501 base Knight fire alarm control panels: Microsoft,Windows,and the Windows Logo are Weight:3.4 oz(95 g) 6820:Addressable fire alarm control panel registered trademarks 6820EVS:Addressable fire alarm control panel or trademarks of ENVIRONMENTAL Microsoft Corporation. with an emergency voice system. Operating Temperature range: Silent Knight°,System 6808:Addressable fire alarm control panel Sensor'and Honeywell' Photo:32°F to 122°F(0°C to 50°C) are registered 6700:Addressable fire alarm control panel trademarks of Honeywell Photo with Thermal:32°F to 100°F(0°C to International,Inc. 38°C) 5700:Addressable fire alarm control panel 5808:Addressable fire alarm control panel This document is not UL listed Velocity range:Photo/Photo with intended to be used for 5820XL:Addressable fire alarm control panel installation purposes.We Thermal:0 to 4,000 fpm(0 to 20 m/sec) tryto keep our product (suitable for installation in ducts) 5820XL-EVS:Addressable fire alarm control information up-to panel with an emergency voices stem date and accurate.We Humidity:l0%to93%non-condensing p g y y cannotcover all specific applications or anticipate Thermal Ratings:Fixed Temperature Set point: AGENCY LISTINGS AND APPROVALS all requirements.All 1350F(570C) For exact certification listings for each model, specifications are subject please reference the respective agency Web site. to change without notice. ELECTRICAL RATINGS UL listed:S6173 For Technical Support, Voltage Range:15 to 32VDC peak FM approved call800-446-6444. CS FM:7272-0559:0523 Operating Current C 24VDC:200µA(one communication every 5 seconds with green LED blink on communication) Maximum Current:4.5mA @ 24VDC(one communication every 5 seconds with amber LED solid on). For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell N o rthfo rd,CT 06472 Doc 3516341 Rev A 104/18 SILENT' 800-328-0103 ©2018 Honeywell International Inc. 0 KNIGHT SYSTEM SENSOR° Indoor Selectable- Output Strobes and 4*� Horn Strobes for Ceiling Applications f System Sensor L-Series audible visible notification r products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring, installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING & F M X APPROVED LISTED 55512 FM approved except 7125-1653:0504 54011 for ALERT models 7135-1653:0503 3057383 AVDS868-02•12/01/2017•Page 3 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02.12/01/2017•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.11K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.11K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02•12/01/2017•Page 3 L-Series Dimensions 2.47"(62.7 mm) 1.37"(34.8 mm) 6.92"diam. 2.5' 6 diam. (175.77 mm) (64 mm (17 )� (173 mm) a•\a*r.rMr o TR O rn 0 o CDo 0 o 00 O O o Q o 0 A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box ® ( a 0 PA\NT OOO�o®mmm o0�0� O oOpem®0 00 • ® o�n — opu° / pp ppp °$o poo �000 • �°0000 0 � ovo A0494-01 A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". SYSTEM ©t to c System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensoccom SENSOR" Phone:800-SENSOR2•Fax:630-377-6495 or current product information,6,-02ng the latestversion ofthis data sheet. AVDS868-02•12/01/2017 SYSTEM SENSOR° FI I I I F - Indoor Selectable- Output Horns, w tr n Strobes, and Horn Strobes for Wall Applications I System Sensor L-Series audible visible notification products are rich with features guaranteed to cut - t, installation times and maximize profits with lower 1 current draw and modern aesthetics. } '� Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red plastic housings,standard and compact devices,and plain, FIRE, • Tamper resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns,strobes,and horn strobes 15,30,75,95, 110, 135,and 185 include a variety of features that increase their application versatility • Horn rated at 88+dBA at 16 volts while simplifying installation.All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage,the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING & F M ® APPROVED LISTED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383,3057072 AVDS865-05•2/22/2018•Page 1 L-Series Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'M Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 1.91-D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.25-D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05.2/22/2018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(rnA RMS) UL Max.Horn Current Draw(rnA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(rnA RMS),Wall Horn Strobe,Candela Range(115-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.11K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.11K Non-Temporal High 104 131 177 204 230 264 326 3.1 K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data StrobeHorn and Horn • .: 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9" Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 "Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVDS865-05•2/22/2018•Page 3 L-Series Dimensions 1.91, 3.46" 3'46" 48.5 mm 88 mm 1.25" 3.57 1.55, 88 mm 1.25" 32 mm (9.1 cm) (3.9 cm) 32 mm 0 0� 0 001.4 0 0°6 UP o e e e°e a e°e oo 0°°°o°o0°°°0°0 eeeree ° 5.27" .e e e e e° °o°°°°°°°°°°° 5.38" 133.9 mm � 5.27" popopopapoQao (13.7 cm) O 133.9 mm °°°°°°°°°°° 0 eeeeaeeeoeeeo A0548-00 A0547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL 4.70" (11.94 cm) 1.911, 4.7" __ 1.25" 1.25"cm) 119 mm 424 .69 c 1.25" 32 mm (12.24 cm) (4.69 cm) (3.18 mm) ic. oa00000° 68 cm)(14.4 cm) 144 mm °°°°° A0550-00 A0549-00 A0554-01 Strobe,Horn Strobe Horn Wall Surface Mount Back Box SBBRL/SBBWL L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns* P2RL 2-Wire,Horn Strobe,Red HRL* Horn,Red P2WL 2-Wire,Horn Strobe,White HWL* Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL* Compact Horn,Red P2GWL 2-Wire,Comp 2 fils act Horn Strobe,White HGWL* Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBWL Wall Surface Mount Back Box,Red P4RL 4-Wire,Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe,White SBBGWL Compact Wall Surface Mount Back Box, Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe,Red SWL Strobe,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover). All-SP models have"FUEGO"marking on cover. All-ALERT models have"ALERT"marking on cover. *Horn-only models are listed for wall or ceiling use. SYSTEM3825 Ohio Avenue•St.Charles, IL 60174 ©2018 System Sensor. SENSORw Phone:800 SENSOR2•Fax:630 377 6495 Product rcurre current product sumatioct o change without nonce.version corn et. for current product information,including the latest version of this data sheet. www.systemsensor.com AVDS865-05.2122,/2018 NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY APPROVED PERMIT#: ❑ AM Cl PM DATE: JOB ADDRESS: 17 Cr o l �`t A J f N t_ LOT#: PROJECT: ' Mo.u. &,- Qc,. , Ce J e i TYPE OF INSPECTION: I-. fz P61 e,4�—,54SA —'s F OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS 1,%d,WCATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE 0 PLANNING 0 CIVIL O BUILDING CITY OF ARLINGTON ' ,N CITY OF ARLINGTON 18204 59th Avenue NE, Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BLTLDING PERMIT Permit#:3549 17601 59TH AVE NE PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Parcel#: 31052200400200 Valuation: 700.00 OWNER APPLICANT CONTRACTOR PUBLIC UTILITY DISTRICT NO 1 Suppression Systems Inc. Suppression Systems Inc PO BOX It 07 3077 20th Street E, Suite B 3077 20th Street E,Suite B EVERETT,WA 98206 Fife,WA 98424 Fife,WA 98424 253-926-3300 253-926-3300 LIC:SIJPPRS1044RR EXP: 12/162022 MFCHANICAL CONTRACTOR PLUMBING CONTRACTOR LTC:4: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT'TYPE: Fire Sprinkler CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL The issuance or granting of this pen-nit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT 1S UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UN'rIL A FINAL INSPECTION HAS BEEN MADE ANI)APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC IO/IRC 110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded C'of Arlington#3101. 3 73 z Signature Print Name Date Released By Date CONDITIONS Fire AlannNESDA 1.Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request.2. Battery load test required,switch system to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3.Trouble condition to be verified for initiation,notification and signaling circuits.4.Furnish a written statement to the Arlington Fire Deparhnent stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). Clean Agent System 5. Functional acceptance test to be witnessed by AHJ and comply with NFPA 2001 Section 7.7. The record of completion forms for each system shall be submitted prior to project close-out.Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED."PHIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL.REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 03/22/2021 Processingfrechnology Fee $25.00 03/22/2021 Fire System Plan Review $100.00 03/22/2021 Fire Alarm System Permit $300.00 Total Due: S425.00 Total Payment: $0.00 Balance Due: $425.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon " CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT Permit#: 3549 17601 59TH AVE NE PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Parcel#: 31052200400200 Valuation: 700.00 OWNER APPLICANT CONTRACTOR PUBLIC UTILITY DISTRICT NO 1 Suppression Systems Inc. Suppression Systems Inc PO BOX 1107 3077 20th Street E, Suite B 3077 20th Street E, Suite B EVERETT,WA 98206 Fife,WA 98424 Fife,WA 98424 253-926-3300 253-926-3300 LIC:SUPPRSI044RR EXP: 12/16/2022 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Sprinkler CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCl10/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By Date CONDITIONS Fire Alarm/VESDA 1.Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request.2.Battery load test required,switch system to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for initiation,notification and signaling circuits.4.Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). Clean Agent System 5.Functional acceptance test to be witnessed by AHD and comply with NFPA 2001 Section 7.7. The record of completion forms for each system shall be submitted prior to project close-out. Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 03/22/2021 Processing/Technology Fee $25.00 03/22/2021 Fire System Plan Review $100.00 03/22/2021 Fire Alarm System Permit $300.00 Total Due: $425.00 Total Payment: $0.00 Balance Due: $425.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon SNOHOMISH PUD S I L E NT AI RE Suppression Systems Inc. scope of work is to provide Final connections, Integrity test, commission, and final inspection of SUPRESSION SYSTEMS, INC. 1 clean agent fire suppression system with addressable SPECIAL HAZARD FIRE PROTECTION detection and controls and VESDA smoke detection. 3077 20TH STREET EAST, SUITE BFIFE, WA 98424-1798 C (253)926-3300 FAX(253)926-3306 FOR REFERENCE: Fire Suppression System provided in modules. Site contractor shall reconnect system wiring across module split lines, provide start-up, confidence testing and commissioning of dry agent system and extend system monitoring signals from MDC panel to Fire Alarm panel / DACT in CEC Building. CLEAN AGENT FIRE SUPPRESSION SYSTEM 2122 SILENT AIRE'�) C 2019 Silent-Aire SNOHOMISH PUD Datasheet—(Issued for Approval (Second Submittal)) SILENT A I R EA . 2122 00 CLEAN AGENT FIRE SUPPRESSION SYSTEM Fire Suppression Specification Note: MDC Fire Suppression Product/Distributer: Janus Fire System Design Concentration 4.5 Fire Type Class C Fire Fluid Type Novec 1230 Required Fluid (Lbs) 517.49 Cylinder Capacity(Lbs) 600 Panel Manufacture: Notifier by Honeywell Detection Type Photoelectric&VESDA(Room Sampling) ©2019 Silent-Aire CITY OF ARLINGTON 0 SHOHOMISH CO . PUD - MDC BUILDING y NORTH COUNTY MODULAR DATA CENTER 2813 IcK FELLER AVE BID SET EErT,rA1 PHONE: 425.31TWI 45'q FAX:423.31"l.8489 FROJEGT TEAM FROJEGT SUMMARY 17601 59TH AVE. NE SE 1/4 SEC 22 TWP 31N RGE 05E PROJECT TITLE: NORTH COUNTY RE61srERED MODULAR DATA CENTER INSTALLATION �ARcwrecr OWNER:SNOH 51TE ADDRESS: 19601 5gTH AVE.NE, SITE ADDRESS AND 2320 MISHCO.PUBLIC UTILITY DISTRICT NO. ARLIN&TON,INA. 98223 J U R I S D I CT I O N 320 CALIFORNIAALI ST. EVERETT,WA. g8201 JURISDICTION: CITY OF ARLIN&TON DISTRICT CONTACTS: DEPT.OF COMMUNITY R ECONOMIC DEVELOPMEN 6EOR6E HESPE 18204 59TH AVE NE (425)367-10g2 ARLIN6TON,WA. g8223 GRHESPE®SNOFUD.COM (360)403-3551 BEN DAVIS PARCEL NO.: 51052200400200 (425)251-2145 Z NIN(S• GENERAL INDUSTRIAL = BRDAVIS®SNOFUD.COM 5 CT- B - a EQUIPMENT SUPPLIER/COORDINATOR: USE CLASSIFICATION: 19.200 INDUSTRIAL AIR SYSTEMS,INC. PAR/-EL SF)EL SIZE: 25.bq AG.(I,IIgp56 8bO2 MALTBY ROAD LEGAL DESCRIPTION: SEC 22 TWP 31 RGE 05RT-24)TH PTN 51/2 NI/2 WOODINVILLE,WA. 1180-72 5EI/4 LY W OF NP R/W EXG N 55OFT OF W CONTACT: DEREK TOR&ER50N 1124FT THOF (206)50-5115 OCCUPANCY: NON-OCCUPIED EQUIPMENT MODULE DEREK.T®INDAIR.NET REQ.BUILDING SETBACK: 5 FT.(FROM LOT LINE); ACTUAL=60' `. O STRUCTURAL ENGINEER: REQ.HEIGHT LIMITATION: 50 FT. ACTUAL: KPFF CONSULTING ENGINEERS IMPERVIOUS SURFACE: 5.58 AG EXI5TIN6 1601 5TH AVE. #I600 NO ADDITIONAL PROPOSED SEATTLE,M. g8101 REQUIRED PARKING: NO ADDITIONAL REQUIRED THIS PROJECT CONTACT: ANDY EWIN6 (206)g26-04g4 UTILITY PROVIDER: WATER/SAN.SEWER BY CITY OF ARLIN6TON w ANDY.EWIN6®KPFF.COM NO SAN.5ENIER TH15 PROJECT MODULE SIZE: 1,154.0 90.FT. MODULAR DATA CENTER — SOUTHEAST VIEW o MEP/SECURITY/TELECOM: MODULE MANUFACTURER: 51LENT-AIRE LOCATION OF 50ALE: N.T.5. O HARG15 CONSULTING EN&INEER5 MODULE SIZE: 24'X 46' 1,154.0 50.FT. MODULAR DATA r z 1201 3RD AVE. #600 APPLICABLE CODES: AS AMENDED AND ADOPTED BY AA.STATE: SEATTLE,WA. 9801 ,I n CONTACT: BRIAN CANNON 2015 INTERNATIONAL BUILDING CODE (206)436-0405 2015 NTERNATIONAL MECHANICAL CODE CENTER BRIAN.GANNON®HAR615.5IZ 2015 INTERNATIONAL FIRE CODE ko,2015 UNIFORM PLUMBING CODE . aO LANDSCAPE ARCHITECT: DEFERREDSUBMITTAL: ELECTRICAL PERMIT THROUGHWA.STATE QNAKANO ASSOCIATES LABOR f INDUSTRIES - Ave.NE J Q J 555 HIAWATHA PLACE S. _ '• t t . SEATTLE,WA. g8144 I' J CONTACT: PAULA 61LMOREModular Data Center(this projec*.)--- Q (206)2112-g3g2 P6®NAKANOA55OC I ATES.COM Existing CETC Building ARCHITECT: } z FH CAPITAL ARCHITECTS GROUP z 2815 ROCKEFELLER AVE. e 0 � EVERETT,WA. g201 8 W CONTACT: TOM GRIFFIN (425)31"I-8017 U z TOM®CAPARCHGROUP.COM _ WTI, = W AERIAL SITE VIEW ® Q 5GALE: 1" = 250' O zQ 0 180TH ST.NE W - z SHEET TITLE: n T 1J Modular Data p AIRPORT Center COVER SHEET Lij 0 01 Exist.CETC Building z z w Ui DATE: 6/05/20 � w a JOB NO.: _ BID SET F ONE INCH AT FULL SCALE. IF NOT,SCALE ACCORDINGLY w• SHEET: -T _ 172ND ST.NE T- 1 .0 V I G I Y MAF FOR 5GALE: N. S. SHEET 1 OF 24 Mechanical General Notes: Piping CB 1. For 360 psig systems, schedule 40 black or galvanized pipe may be used as follows: XFRSW PNL GHA POM MINI POWER '� / �' " " A-53 Grade A, ERW sizes 1/4 in. through 3 in. threaded end ATS 1 480V ZONE A-53 Grade A, ERW welded connections 1/4 in. through 3 in. 4 A-53 Grade A,B Seamless with welded or threaded connections sizes 114 in. through 3 in. 3 A - A-106 Grade A,B,C welded or threaded connection 1l4 in. through 3 in. /22 � 400A BUSWAY Installation r� 11/11/2019 B ISSUED FOR CLIENT REVIEW i Res 19SFRVFR I9'SFRVER VRvER BSERVER ,9SEER BSERVETi 9BERYER 195ERVER , 1. Cylinder location to be maintained at an ambient temperature of OC NOT FOR CONSTRUCTION 4%TACK '°"'�K 'BD RACK '•,RACK ABU RACK 'a'RACK 4eJ RACK 'BU RACK Q�RACK (3 2 F) or 49 C (120 F) REVISIONS: 2. Single cylinder straps when attached to solid walls should use star ENG/NNER STAMP grispin alloy expansion shields for use with machine bolts (or equivalent). Lead shields are not acceptable. Minimum bolt size of 3/8" 120KVA UPSA 120KVA UPSA 3. Pipes to be swabbed clean internally of all cutting oil, metal chips, PNL UDSA etc. prior to assembly using degreasing solvent and rags. WITH BYPASS BATTERY P Y 9 9 9 9 CABINET CABINETS 208V 4.All threaded joints to use Teflon tape or similar lubricant applied to 150KVA � � male threads only. f XFMR-A 5. Piping shall be hung securely as per ANSI B-31.1. 6. Piping to be fastened securely and braced against thrust forces at - all nozzles and change direction fittings. 120KVA UPSB 120KVA UPSB PNL UDSB 7. Piping 8L tubing should be reamed free of burrs and ridges. 2�8V WITH BYPASS BATTERY F 8. Before installing nozzles, all pipes to be pressure tested for leakage CABINET CABINETS 1 OKVA XFMR-B and blown out using dry compressed air or nitrogen +e SERVER 9.All nozzles to be mounted with nozzle orientation as shown. °K ^CK 10. No deviation may be made to piping layout without the approval of 745U RACK 145LJ PACK 19•UMK 14BU RACK t4 RACK +9'SERVTR t4%RA K 2MR&OR z+'UWK Y P P 9 Y PP 45U RACK /6uRACK 41,RACK aSURACK 45uanCK .SCru K 's`"D- '°�RAc the installing company. Pipe lengths are approximate and not to be rLAP°P 7Ar ~ 'r used for prefabrication. " 100A Bll$3N6Y_ST -FN �--. m • 11. In total flood systems doors, windows, etc. to be sealed against cTA ION .13 _ loss of agent using weather strip or "sweeper" gaskets to aid in retention of extinguishing agent. 12. Quantity of NOVEC 1230 supplied is based on calculations done using drawings and information supplied. Additional gas requirements due to changes in dimensions, un-closeable opening or other conditions not indicated in the information received will be extra. PNL GHA MINI POWER FIRE ALARM HOVE 13. Dimensions shown on drawings are for estimation and calculation 480V POM ZONE SECURITY CONTRU'• purposes only.Actual site conditions may require some changes.Any XZZZZZZZrlr; o „BACKBOARD PANEL 12 0 114 Tlrrrrrrrrrrrrr � a _ rrr�rrf-rrrrr��rr »rr major deviations must be approved prior to completion. Discharge Nozzles SCALE 1/4"=1'-0" Nozzles must be located at or near the ceiling with the halfway point between the two vertical orifice layers no more than 4ft 5in (1.346m) below the ceiling. The maximum height for a single tier of nozzles is 18ft 4in (5.588m) from the floor to ceiling. For ceiling heights greater SUPERVISORY PRESSURE SWITCH AssEMeLr than 18ft 4in (5.588m), additional tiers may be installed so that the (PN 1875) _ maximum distance between the floor and the lowest row does not MERIDIAN J MANUAL -, exceed 18ft 4in (5.588m) and the maximum distance between rows UQUID LEVEL ACTUATOR 1/4 in[8 mm]NPT does not exceed 18ft 4in (5.588m). Each nozzle must be positioned FIRE PROTECTION PRESSURE� PN 17001(DS-101) TO 1/4 in[8 mm] vertically, installed either on the bottom or top of a vertical pipe ASSEMBLY � JIC ADAPTER (PN 1872) \'� PN 18625 section and should be placed as close to the cylinders as possible to ELECTRIC (SEE NOTES minimize system piping. The ceiling tiles around each nozzle must be ACTUATOR FORSv clipped to hold them in place during the discharge and to prevent CYLINDER) 1.LISTINGS: damage. MANUAL ARIMTOR(PN UL,R4 - - f� yr a 1J001) -ExTwc ACTUATOR(PN z.TECHNICAL in 8 mmCAL DATA: �. -..,",� [ 1 NPT LIQUID LEVEL INDICATOR : IOC ADAPTER m] -APR1f1A770N CYLINDER IS USED TO LY V (PN HOUSE THE FM 200 AGENTAHI.2OSSx; .!AVE \HDS2956x; I 1 PN 18625 -RATED WORIUNG PRESSURE.502 PSI 6130 ` Room Volume and Agent Requirement Calculations: [ � 'F[34,62BAR054.4'Cl DI CHAR E PRESSURE SWI7 CYUNNDER LAPEL(PN -NOMINAL ' 1 70 NONAL A 21.1E55UREH60P514f Inside Dimensions = 47.25 X 24 X 11.2 -' "F(24.82 LV B AAR 21.1°C) ".. -HYDROSTATIC TEST PRESSURE:1000 PSI _. [68.97 BAR) • FLEX HOSE Total Volume = 12 AE�r --: (COMES IN VARIOUS LENGTHS) At 4.5% concentration = 518 LBS -WEIGHT:SEE TABLE -TEMPERATURE RANGE(INDOOR B CLEAN AGENT VALVE \ _^` :�.�' Total Agent Supplied = 518 LBS O O OUTDOOR):.°F TO I..(0°C TO 5C4 _.'` \� a c ZE) WIT. 3. i_# - "Agent requirements calculated per NFPA 2001(2012), section 5.4.2.5 at J SIZE) 3.MATERIAL: -. g q P -SCOY:CYLINDER BODY IS LIGHT WALED, CLEAN AGENT �, SUPERVISORY PRESSURE SWITCH 70F. at Oft above seal level. Refer to hydraulic calculation files for z V48XED SEAM STEEL AND THE VALVE IS BRASS PRESSURE GAUGE additional details. O C -FINISHCOLOR-RED CYLINDER WITH BRASS RUPTURE DISC CLEAN AGENT CYLINDER "For energized electrical hazards less than 480 Volts . Equipment in V NOTE (COMES IN VARIOUS SIZES; excess of 480 Volts must be de-energized prior to agent discharge or J -MANUAL ACTUATOR(PN 17001),ELECTRIC 1000 LB CYLINDER SHOWN W acnATOR LPN IBIB%SUPERVISORY FOR REFERENCE) design concentration /agent quantity must be increased. Per FM data = STOCK NO. '' DIM'B' OB4'C KEN FILL WEIGHT MAX FILL WEIGHT VALVE SIZE sheet 4-9. W (n O 18527 600 LB R4 2O0 SD-I1/16 in 4+15/161n N In(609.6 mm) 00418[137.9 KG] 609 La[z76.z KG] UV 119 r'AM' 62-3/1mm] TYPICAL MASTER CYLINDER IBM 900IS f61200 75.15/16 m 62.3J16 ti 24 to[809.8 mm] 455 LB[206.4 KG] 910 LB[412.710G] lv O 1928.8 mm 1579.1 mmj „m 1000 La R,200 67-In in 0-�. 30ti[762 mm] 561 LP 1254.S KG] =0 US[4S3b KG] Lv TRIM DETAIL IL 11714.5 mm 1364.E mm] _ 2 W w D6-008 4 SEE TABLE S W CYLINDER,FM200,ASSEMBLY,Lv SERIES MECHANICAL B O M � Z LL PN# DESCRIPTION Qty. Z Q 1 22954-518 Cylinder, LV 500 Seriese,600 lb w/518 lbs. Nove .1230 1 U 0 18536 Cylinder wall bracket-24" 1 `� Z 18649 Hose, Flex,3(16 inch, 1/4 inch JIC Female 8mm ,24 inch long 1>_4 Q 18773 Switch,Discharge Pressure 1 = 19533 Nozzle,360 deg. Brass 3 V 20722 Actuator,Valve,Electric,w/Supervisory limit switch 1 W 17001 Manual Valve Actuator 1 111 Q 22943 Gauge Assembly, Pressure, Novec 1230 Fluid,500 Series 1 Z w 22946 Switch Assembly, Low Pressure Supervisory,500 Series 1 Q EXITSIGN Sign,Warning, Exit,'Leave Area',Clean Agent 4 m W O ENTRYSIGN Sign,Warning,Entrance,'Do Not Eater,Clean Agent 4 O = (Ji DRAWN BY: KR � I DATE: 11/05/2019 I LVB00 CYLINDER Bt YOB #: XXXXX SHEET NO: FP-1 Electrical General Notes: JOIN CB AWIP 1. Wiring shall be looped through device terminals. Wire must be cut for in and out circuits �. C �� " Mo11 �BMo10 XFR SW PQM MINI POWER vLF " � „ ,' 2. T"-Tapping of wiring is prohibited, except for class "B' style 4" PNLGHA UP MD16 Mo15 signaling line circuit (SLC) addressable loop wiring ® ATS 1 480V ZONE X x 3. The fire alarm control panel and power extender panels are not to be 4 x �l DM N�� 0006e used as a terminal cabinet. All wiring into panels shall be landed onto a ro riate terminal only. No splicing or through wiring will be 3 M012 M013 pP p Y p 9 9 g r N U/S PLENUM M014 A allowed In panels Dooa 400A BUSWAY i - 4. All fire alarm wiring must test free of opens, shorts, and grounds 2 M009 B - 5. All wiring must enter at the top of the fire alarm control panel and 1111112019 power extender panels 1 ', ISSUED FOR CLIENT REVIEW ❑R R/APLENUM 9StrrtK 191SERVER 19'SERAR IVSERVER 191SERVER 1S•SERVER 19'SERVER 17SERVER ITSERVEII 11, ER 6. This control panel requires connection to separate dedicated A/C NOT FOR CONSTRUCTION x 4AURAGK AC RACK buRACK MU RACK Ia1RACK FBURACK 48,RACK 18URACK saIRY1CK IMXbranch circuit. Follow these guidelines when connecting the A/C REVISIONS: branch circuit ENGINNER STAMP _ -Label the branch circuit fire alarm breaker and it shall be locked in the "on" position and painted red 120KVA UPSA 120KVA UPSA PNL UDSA \ s� -Connect the branch circuit to the line side of the main power feed of l4 WITH BYPASS BATTERY eDoo2 208V eDo07 the protected promises. U CABINET CABINETS -Do not power other equipment from the fire alarm branch circuit - 150KVA -Run branch circuit wire continuously, without any disconnect e U/SPLENUM XFMRA devices, from the power sources to the fire alarm control panel _ 3 -Over-circuit protection for the circuit must comply with article 750 of s' the National Electrical Code as well as local codes 120KVA UPSB 120KVA UPSB x PN!UDSB 7. All wiring to be complete in accordance with the latest addition of WITH BYPASS BATTERY 208V f all applicable national, provincial, and local codes such as building, 150KVA CABINET CABINETS XFMR-B electrical, and ULCS524 Standard for Installation of Fire Alarm :+ x x 10 ERVER Systems A8U WK tgSFRVER tYSE13VR 175ERurR IV SERVER tvSERVER tg'SERVER t9•SERVER 23'SERVER 73.5ERVER 8. The total resistance of the communication loop pair cannot exceed �( 451 tU.CK /50 RACK 45l PACK 45U RACK 45U RACK /SU RICK I%RICK 45U RACK 16URACK__. LAPTOP A 50 ohms. TDl1CH 100A BUSW�iY 9. Communication loop circuit (SLC) shall be twisted-unshielded pair UP X LOCATE ABOVE SCREEN TATTIION � ° m m � limited energy cable enclosed in emt conduit B r 1008 CONTROL PANEL �' 10. For detectors shall be mounted a minimum 36" from air supply LOCATED BYCYL DER outlet or 24" from air exhaust outlet. A clear space of at least 24" shall r (REFER TO DETAILS AGE 3) Ell be maintained in the ceiling below and around the detector eDoo1 H 0 PRR ODooe 11. Clear space shall be maintained in front of the control unit equal to MOOS M003 M002 ,I;A the width of the door or to a minimum of 40" to provide room for Mooa , maintenance and testing. FIRE ALARM © PNL GHA MINI POWER CONTROL NOVEC ® I 12. Alarm, trouble, and supervisory relay contacts -dry form -C rated: D 480V PQM ZONE SECURITY PANEL 1230 2.OA @ 30VDC (resistive), 0.5A @ 30VDC (resistive) M007 LA e moos-3 a, BACKBOARD _.ad LO v_ M018 0 BM017 '_� 13. Refer to notifier SLC wiring manual, document#51253 for Mao- additional information. SCALE 1/4"=1'-011 �W/P EVENTTYPE 1 2 3 14 15 E 17 18 19 110 1'I 1 13 14 [Control ntrol Panel Fault Condition LOW CYL. DISCH. CONT.HEAD Head-ONcylinder PRESS. P.S. POSITION Lockout Switch Operated Low Cylinder Pressure C\ C I VESDA"Fault"or"Isolate" -VESDA"Alert "Action""Fire 1" LOi RCj —D1 1.4 DM .n. «�n I D� 1 st Alarm(VESDA"Fre 2"or smoke detect M001 M002 M003/M004 M005 D004 M006 M007 woe D003 M009 MO10 MO11 D004 D002 2nd Alarm(VESDA"Fire 7'or smoke detector Agent Release Manual Release Station Activated Manual Abort Station Pressed and Held 12VDC AUX.POWER p VLF500, SEQUENCE OF OPERATION MATRIX(TO BE REVIEWED BY CLIENT) H H H WIP J.H.IWIp ELECTRICAL BOM H M z M017 Mole DOOB D007 DOOR M015 M016 D005 M013 M014 M012 DEVICE PN# DESCRIPTION QtyVESDA , J ACTION VESDA VESDAFAULT ® NFS-320 NotifierAddressableControlPanel 1 W � REFER TO DETAILS(PAGE 3) FSP-951A Low Profile FlashScan Photoelectric Detector FOR CONNECTIONS N/A B30OA-6 Intelligent Base,Low profile,flanged 8 O ® FDM-1A FlashScan Dual Monitor Module.Class B wiring only 7 Q O FMM-101A FlashScan Miniature Monitor Module 1" W 'L�"DC"D " - 0 FMM-lA FlashScan Monitor Module 1 � © FCM-1-REL Releasing Control Module 1 W O o me-mewl ,° �.1➢{�id$ o R FRM-lA FlashScan Relay Module 2 A/ a __�CIRc N LL m NBG-12LR Pull Station Dual Action KL Release 4 � O W wa(mm)cwcoi a " 18447 MAS-1 Manual Abort, Momentary 4 Q _ ® RELA-SRV Service Disconnect Switch 1 0 U. a " 5�wv P4RKA Selectable Horn/Strobe,Wall,Red, Weatherproof 2 z J ["4 P2RLA-E Selectable Horn/Strobe,Wall,Red 3 Z Q VLF500 Vesda LaserFocus 500 1 W V 0 0 0 0 0 0 J m 0 0 0 0 COWACRAL 0 0 0 0 0 @E� (/� U a � ® � 6 J ,f 1M Hn 8 • IfI.SCYARO� [� ® a v� FNS W!�URY SFCUR�TY SU�E.MiSOiIYT Irs S'Si�EIY=-•.1 OAM.F[l `--\� W W O 8988 O ALANN CONNECTIONS - _ FOR REMOTE Q MONROPoNG ��? , FCrtOi_'pAFa,Av s r "9,? gRne '=Fs1 _ W Q RISE UP S� r r ,utw0 Q Z 0 L 001IDL000000 ID E)mm O Z W S0000-100ID0 ® 0'�M0 m W O = � I(n 12V!26Ah 12V/26Ah PROPOSED VESDA RISER DETAIL 5esdet stop PIPE LAYOUT (NTS) DRAWN BY: KR (NTS) DATE: 11/06/2019 JOB #: XXXXX RISE UP SHEET NO: FP-2 oo MERIDIAN , AFSA FIRE PROTECTION Silent-Aire Manufacturing Oct 11, 2019 7107—81" Street NW Edmonton,AB Our proposal is based on the supply and installation of Novec 1230 fire suppression hardware manufactured by Janus Fire Systems and a fire detection and control system manufactured by Notifier. Details of our proposal are as follows: A/System Description: Our quotation includes for the installation a Novec 1230 fire suppression system comprising agent storage cylinder and trim as well as discharge piping and nozzles. An addressable detection and control system including photoelectric smoke detectors, VESDA LaserFocus detector, manual release/abort station, shutdown relays, audible/visual alarms in the building and weatherproof horn/strobe outside the building by each exit door will also be provided. B/Agent Calculation: Dimensions:47.25' L x 24'W x 11.2' H Approximate volume 7813 ft3 For 4.5%concentration = 319 Ibs Novec 1230 (*see General Notes Section) C/Equipment List: Qty Part# Description 1 NFS-320 Addressable control panel 8 FSP-951A Low-profile FlashScan photoelectric detector. 8 B30OA-6 Intelligent Base, low profile,flanged 7 FDM-1A Flashscan dual monitor module. Class B wiring only. 1 FMM-101A Flashscan miniature monitor module. 1 FMM-1A Flashscan monitor module 1 FCM-I-RELA Releasing Control Module 2 FRM-1A Flashscan relay module. 4 NBG-12LR Pull Station Dual Action KL Rel 1 RELA-SRV Service Disconnect switch 2 4503 Morris Rd Edmonton,Alberta T613 2V9 P:780.462.0580 F:780.462.0990 www.meridianfire.ca oo MERIDIAN , AFSA FIRE PROTECTION Page 2 C/Equipment List(cont'd): 4 18447 MAS-1 manual abort, momentary 2 P2RKA Selectable Horn/Strobe, wall mount, red, weatherproof 3 P4RLA-E Selectable Horn/Strobe, wall mount, red 1 17001 Manual Valve Actuator 1 VLF500 VESDA LaserFocus ASSD 4 ENTRYSIGN Sign, Warning, Exit, 'Leave Area', Clean Agent 4 EXITSIGN Sign, Warning, Entrance, 'Do Not Enter...', Clean Agent 1 18536 Bracket, Cylinder, 24 Inch, Kit 1 18649 Hose, Flex, 3/16 Inch , 1/4 Inch JIC Female (8 mm), 24 Inch Long 1 18773 Switch, Discharge Pressure 3 19533 Nozzle, 360 deg. Brass 1 20722 Actuator,Valve, Electric,w/Supervisory Limit Switch, 1 22954 Cylinder, Novec 1230 Fluid, My 500 Series, 600 lb 1 22943 Gauge Assembly, Pressure, Novec 1230 Fluid, 500 Series 1 22946 Switch Assembly, Low-Pressure Supervisory, 500 Series 518 NOVEC1230 Agent, Novec 1230 Fluid 1 Lot Mechanical installation labor and material 1 Lot Electrical installation labor and material (*see General Notes) E/General Notes: - In order to maintain an effective extinguishing concentration for an extended period of time a reasonably well sealed enclosure is required.This includes but is not limited to sealing around door frames, shutting off and/or installing leakage rated dampers in forced supply and/or return air and sealing any additional penetrations into the room. For rooms with protection below a suspended ceiling only, it is strongly recommended that perimeter walls around protected space extend to the upper deck and are sealed. 3 4503 Morris Rd Edmonton,Alberta T613 2V9 P:780.462.0580 F:780.462.0990 www.meridianfire.ca oo MERIDIAN , AFSA FIRE PROTECTION Page 3 E/General Notes(cont'd): - For "Class C" electrical hazards, NFPA 2001 and FM Global data sheet 4-9 stipulates that for energized electrical equipment with voltages greater than 480 volts a higher design concentration must be used subject to testing. For Novec 1230 a 10% design concentration would be required unless the equipment is de-energized. - The specification indicates a design concentration of 6.5% Novec 1230 (sec. 1.03 item B).This is not a standard design concentration for any electrical hazard. Our proposal is based on 4.5% concentration per NFPA 2001 (see above note) - All conduit to be installed by Silent-Aire. Meridian Fire Protection will pull all wiring and terminate/mount devices, install control panel components and terminate control panel wiring. We trust this information will be of assistance to you. Should you have any questions regarding this matter, please do not hesitate to contact me. Regards, f Craig Powley Meridian Fire Protection 4503 Morris Rd Edmonton,Alberta T613 2V9 P:780.462.0580 F:780.462.0990 www.meridianfire.ca 1 �4)ANUS FIRE SYSTEMS' TM Janus Fire Systems Novec 1230 Fluid Hydraulic Flow Calculation Program Agent Calculation Requirements Calculation Program Version 2.10.11.6 Calculated by: Meridian Fire Protection Inc. 4503 Morris Road Edmonton, Alberta T6T1H8 MERIDIAN Canada Phone: 780-462-0580 Fax: 780-462-0990 Designed By: Craig Powley Project Name: Snohomish PUD Project Number: Hazard Agent Requirements Enclosure Name: Whole Building: Building Design Concentration: 4.5 Fire Type: Class C Fire Hazard Temperature (F): 70.0 Total Volume (Cu.ft.): 12,700.8 Altitude: 0 Agent Requirement Formula for NOVEC: W = (V/s (C/(100 - C))) * Altitude Correction Factor Where: W = Weight of agent required V = Volume (Cu.ft.) s = 0.9856 + 0.002441(t) t = Temperature (F) C = Design Concentration s = 1.15647 Altitude Correction Factor: 1 W = 12,700.8 / 1.15647 (4.5 / (100 - 4.5)) * 1 Total quantity of Novec 1230 Fluid required is: 517.49 Ibs Page 1 (End of Report) & Your gateway to a new kind of service. LISTED LISTED 1 �4)ANUS FIRE SYSTEMS' TM Janus Fire Systems Novec 1230 Fluid Hydraulic Flow Calculation Program Result Printout Calculation Program Version 2.10.11.6 Calculated by: Meridian Fire Protection Inc. 4503 Morris Road Edmonton, Alberta T6T1H8 MERIDIAN Canada Phone: 780-462-0580 Fax: 780-462-0990 Designed By: Craig Powley Project Name: Snohomish PUD Project Number: System Constraints Name of Hazard Whole Building Storage Pressure (psig): 500 PSI Calculation Report Date: 11/11/2019 Initial Cyl. Storage Temperature (F): 70.00 Calculation Revision: Qty of Main Cylinders: 1 Mid Discharge Cyl.Pressure: 196 PSIG Qty of Reserve Cylinders: 0 Cylinder Fill Density (Ibs/cu.ft.): 60.92 Total Amount of Agent (Ibs): 530 Percent of Agent in Pipe: 22.75% Altitude Relative to Sea Level (ft): 0 Average Discharge Time (sec): 9.82 Type of Cylinder: Lv 600 Cylinder Cyl. Volume (Cu.ft.): 8.7 Hazard Characteristics Enclosure Name: Building Fire Type: Class C Fire Design Concentration: 4.5 Hazard Temperature (F): 70.0 Nozzle(s) Used: 301 - 360' Nozzle, Brass Dimensions (ft): 47.25 X 24.0 X 11.2 302 - 360' Nozzle, Brass Total Volume (Cu.ft.): 12700.8 Total Agent Required: 517.49 Ibs Page 1 (Continued) Your gateway to a new kind of service. LISTED LISTED wx' jANU S FIRE Sl` STE �1ti' TM Janus Fire Systems Novec 1230 Fluid Hydraulic Flow Calculation Program Result Printout Calculation Program Version 2.10.11.6 Piping Network Input -- Section -- Cyl. ------------------------------- Pipe -------------------------------- Tee or Cping/ Nozzle Start End Qty Length Elevation Sched. Size 90's Bends Valve Union Weight 1 2 1 0.0 3.6 SCH 40 3 0 0 None 0 0.000 2 3 0 6.5 6.5 SCH 40 2-1/2 0 0 None 0 0.000 3 4 0 11.5 0.0 SCH 40 2-1/2 1 0 None 0 0.000 4 5 0 9.7 0.0 SCH 40 2 0 0 Side 0 0.000 5 301 0 1.5 -1.5 SCH 40 2 0 0 Blow Out 0 258.745 4 6 0 12.0 0.0 SCH 40 2 0 0 Side 0 0.000 6 302 0 1.5 -1.5 SCH 40 2 0 0 Blow Out 0 258.745 Piping Network Results Section Pipe Size Length Elevation EQL Tee or Start Term Flow Start End (in) sch ft ft ft Valve PSIG (Ibs/sec) 1 2 3 SCH 40 .00 3.55 17.00 None 196 190 53.89 2 3 2-1/2 SCH 40 6.50 6.50 6.50 None 190 181 53.89 3 4 2-1/2 SCH 40 11.50 .00 17.67 None 181 176 53.89 4 5 2 SCH 40 9.70 .00 20.03 Bull 176 172 26.95 5 301 2 SCH 40 1.50 -1.50 11.83 None 172 172 26.95 4 6 2 SCH 40 12.00 .00 22.33 Bull 176 172 26.94 6 302 2 SCH 40 1.50 -1.50 11.83 None 172 172 26.94 Nozzle Performance Nozzle Nozzle Size Stock Nozzle Drill Dia Drill Total Orifice Discharged ID (inches) Number Type (inches) Size Area (sq.in.) (Ibs) 301 2" 19535-090 360' Nozzle, Brass 0.3480 S .761 262.51 302 2" 19535-090 360' Nozzle, Brass 0.3480 S .761 267.49 Page 2 (Continued) & Your gateway to a new kind of service. LISTED LISTED wx' jANU S FIRE Sl` STE �1ti' TM Janus Fire Systems Novec 1230 Fluid Hydraulic Flow Calculation Program Result Printout Calculation Program Version 2.10.11.6 Hazard Concentration Summary Enclosure Enclosure Agent Agent Concentration Pass or Name Volume (cu.ft) Required (Ibs) Discharged (Ibs) Requested /Achieved Fail Building 12700.8 cu.ft. 517.49 530.0 4.50 4.60 Pass Venting Estimate Enclosure Leakage Relative Safety Max. Positive Max. Negative Pos. ELA Neg. ELA Name Area Known Humidity Factor Pressure - PSF Pressure - PSF (sq.in) (sq.i n Building No 36% 1 5 5 60.9 445 Design / Error Messages 1. - Hydraulic calculation was successful. 2. - Version dated 7/1/2013 3. The designer has determined that additional gas for tees, per NFPA 2001 5.5.3.1.1 is not required. 4. - * System is designed to meet Factory Mutual & Underwriters Laboratory design criteria. 5. - All agent requirements were calculated based on NFPA 2001, Table A.5.5.1(a). Statistics of Piping Used (Note: Only U.S Standard Values are used by the math module) Piping information for Pipe Type: -SCH 40 Pipe Metric English Metric English Metric Type of Size (in) Size (mm) ID (in) ID (mm) Ibs/ft kgs/M Joint 2 50 2.067 52.5018 3.65 5.4318 Threaded Page 3 (Continued) Your gateway to a new kind of service. LISTED LISTED 1 �4)ANUS FIRE SYSTEMS' TM Janus Fire Systems Novec 1230 Fluid Hydraulic Flow Calculation Program Result Printout Calculation Program Version 2.10.11.6 Statistics of Piping Used (Continued) (Note: Only U.S Standard Values are used by the math module) Pipe Metric English Metric English Metric Type of Size (in) Size (mm) ID (in) ID (mm) Ibs/ft kgs/M Joint 2-1/2 65 2.469 62.7126 5.79 8.6165 Threaded 3 80 3.068 77.9272 7.58 11.2803 Threaded Note: For Pipe Schedule(s): -SCH 40; these Pipes conform to ANSI A-53/A-106, grade A-ERW or better Data File: C:\Users\cpowl\OneDrive\Documents\My Docs\Janus Novec Calcs\SA Snohomish.JDN Page 4 (End of Report) & Your gateway to a new kind of service. LISTED LISTED DN-7112:M•A-14 N F 320 N OT I F I E R° Intelligent Addressable 0 Fire Alarm System by Honeywell Intelligent Fire Alarm Control Panels General The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX®Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations,ONYX Series products meet virtually every application requirement. The NFS-320's modular design makes system planning easier. _ The panel can be configured with just a few devices for small building applications,or networked with many devices to protect a large campus or a high-rise office block.Simply add additional peripheral equipment to suit the application. Wireless fire pro- tection can be added with the SWIFT wireless gateway and devices. For installations using NFS-320C, an optional ACM Series annunciator can be mounted in the same cabinet (up to 48 zones/points,order separately;see DN-60085). NOTE: Unless called out with a version-specific `R", "C"or"E"at NFS-320 the end of the part number, "NFS-320"refers to models NFS-320, NFS-320R,NFS-320C,and NFS-320E. —Internet/GSM Features 80-character remote annunciators(up to 32). • Certified for seismic applications when used with the appro- EIA-485 annunciators, including custom graphics. priate seismic mounting kit. Printer interface(80-column and 40-column printers). • Approved for Marine applications when used with listed com- History file with 800-event capacity in nonvolatile memory, patible equipment. See DN-60688. plus separate 200-event alarm-only file. • One isolated intelligent Signaling Line Circuit(SLC)Style 4,6 Alarm Verification selection per point,with automatic counter. or 7. Presignal/Positive Alarm Sequence(PAS). • Up to 159 detectors and 159 modules per SLC; 318 devices Silence inhibit and Auto Silence timer options. maximum. NAC coding functions: —Detectors can be any mix of ion, photo, thermal, or multi- —March time. sensor; wireless detectors are available for use with the —Temporal. FWSG. —California two-stage coding. —Modules include addressable pull stations, normally open contact devices, two-wire smoke detectors, notification, or —Canadian two-stage. relay; wireless modules are available for use with the —Strobe synchronization. FWSG. Field-programmable on panel or on PC with VeriFire®Tools • Optional FWSG Wireless SWIFT Gateway supports wireless program check,compare,simulate. SLC devices. Full QWERTY keypad. • Standard 80-character display. Battery charger supports 18—200 AH batteries. • Network options: Non-alarm points for lower priority functions. —High-speed network for up to 200 nodes (NFS2-3030, Remote ACK/Signal Silence/System Reset/Drill via monitor NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, modules. ONYXWorks, NFS-3030, NFS-640,and NCA). Automatic time control functions,with holiday exceptions. —Standard network for up to 103 nodes(NFS2-3030, NFS2- Extensive, built-in transient protection. 640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYX- Powerful Boolean logic equations. Works, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP- 300/400, AFP-1010, and AM2020). Up to 54 nodes when FLASHSCA10 INTELLIGENT FEATURES DVC-EM is used in network paging. Polls up to 318 devices in less than two seconds. • 6.0 A power supply with four Class A/B built-in Notification Activates up to 159 outputs in less than five seconds. Appliance Circuits (NAC). Selectable System Sensor, Multicolor LEDs blink device address during Walk Test. Wheelock,or Gentex strobe synchronization. Fully digital, high-precision protocol(U.S. Patent 5,539,389). • Built-in Alarm,Trouble,Security,and Supervisory relays. • VeriFire®Tools online or offline programming utility. Upload/ Manual sensitivity adjustment—up to nine levels. Download, save, store, check, compare, and simulate panel Pre-alarm ONYX intelligent sensing—up to nine levels. databases. Upgrade panel firmware. Day/Night automatic sensitivity adjustment. • Autoprogramming and Walk Test reports. Sensitivity windows: • Multiple central station communication options: —Ion—0.5 to 2.5%/foot obscuration. —Standard UDACT —Photo—0.5 to 2.35%/foot obscuration. —Internet —Laser(VIEWO)—0.02 to 2.0%/foot obscuration. DN-7112:M•01/25/2016—Page 1 of 6 —Acclimate®PIusTM—0.5 to 4.0%/foot obscuration. FSC-851 INTELLIQUAD —IntelliQuad—1.0 to 4.0%/foot obscuration. ADVANCED MULTI-CRITERIA DETECTOR —IntelliQuadTM PLUS—1.0 to 4.0%/foot obscuration Detects all four major elements of a fire (smoke, heat, CO, • Drift compensation(U.S. Patent 5,764,142). and flame). • Degraded mode— in the unlikely event that the NFS-320's Automatic drift compensation of smoke sensor and CO cell. primary microprocessor fails, FlashScan detectors revert to High nuisance-alarm immunity. degraded operation and can activate the control panel's NAC circuits and alarm relay. Each of the four built-in panel circuits INTELLIGENT FAAST® DETECTORS FSA-5000, FSA-8000, includes a Disable/Enable switch for this feature. AND FSA-20000 • Multi-detector algorithm involves nearby detectors in alarm Connects directly to the SLC loop of compatible ONYX series decision(U.S. Patent 5,627,515). panels. • Automatic detector sensitivity testing (NFPA-72 compliant). Provides five event thresholds that can be individually pro- Maintenance alert(two levels). grammed with descriptive labels for control-by-event pro- Self-optimizing pre-alarm. gramming;uses five detector addresses. FSL-751 VIEW VERY INTELLIGENT EARLY WARNING) Uses patented particle separator and field-replaceable filter to remove contaminants. SMOKE DETECTION TECHNOLOGY Advanced algorithms reject common nuisance conditions • Advanced ONYX intelligent sensing algorithms differentiate FSA-5000 covers 5,000 square feet through one pipe. between smoke and non-smoke signals (U.S. Patent FSA-8000 covers 8,000 square feet through one pipe. 5,831,524). FSA-20000 covers 28,800 square feet through one to four • Addressable operation pinpoints the fire location. pipes. • Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. FCO-851 INTELLIQUADM PLUS FAPT-851 ACCLIMATE®PLUSM ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR LOW-PROFILE INTELLIGENT MULTI-SENSOR Detects all four major elements of a fire. • Detector automatically adjusts sensitivity levels without oper- Separate signal for life-safety CO detection. ator intervention or programming. Sensitivity increases with Optional addressable sounder base for Temp-3 (fire) or heat. Temp-4(CO)tone. • Microprocessor-based technology; combination photo and Automatic drift compensation of smoke sensor and CO cell. thermal technology. High nuisance-alarm immunity. • Low-temperature warning signal at 40OF ± 50F (4.44°C ± SWIFT WIRELESS 2.77-C). • Self-healing mesh wireless protocol. Up to 32 remote displays SLC Intelligent Loop DEVICES �11 0 0 •-===- 0 ��� FWSG C ❑ pp�pp 0 FSC-851 IntelliQuad NBG-12LX I XP6/10 1/0 Modules FAPT-851 Acclimate PLUS FSL 751 FlashScan VIEW FMM-1 FCM-1 FDU-80 FSP-851 Photo IDC NAC LC D2-80 FS I-851 Ion FST-851 Thermal RM-1 FSA-8000 Relay Contact EIA-485 ...etc. EIA-485 2048 annunciator/control points ■ ■ ■ ■ _ ■ ■ ■ ■ ACM-8R ACM/AEM-24AT LDM-32 NFS-320 Relay Control Custom Graphics LED Annunciator Dual phone lines to Optional 318-point UDACT Central Sample Station System EIA-232 Options _1 7112blok-2014.wmf PRN Series Printer Page 2 of 6—DN-7112:M•01/25/2016 • Each SWIFT Gateway supports up to 50 devices: 1 wireless readings over a long period of time, and setting the pre-alarm gateway and up to 49 SWIFT devices. level just above these normal peaks. • Up to 4 wireless gateways can be installed with overlapping Cooperating Multi-Detector Sensing: A patented feature of network coverage. ONYX intelligent sensing is the ability of a smoke sensor to con- RELEASING FEATURES sider readings from nearby sensors in making alarm or pre- alarm decisions. Without statistical sacrifice in the ability to • Ten independent hazards. resist false alarms,it allows a sensor to increase its sensitivity to • Sophisticated cross-zone(three options). actual smoke by a factor of almost two to one. • Delay timer and Discharge timers(adjustable). • Abort(four options). Field Programming Options • Low-pressure CO2 listed. Autoprogram is a timesaving feature. The FACP "learns"what VOICE FEATURES devices are physically connected and automatically loads them in the program with default values for all parameters. Requiring • Integrates with FirstCommand Series. See DN-60772. less than one minute to run,this routine allows the user to have • Telephone applications require NFC-FFT. almost immediate fire protection in a new installation, even if only a portion of the detectors are installed. HIGH-EFFICIENCY OFFLINE SWITCHING Keypad Program Edit (with KDM-R2) The NFS-320, like all 3.0 A POWER SUPPLY(6.0 A IN ALARM) NOTIFIER intelligent panels, has the exclusive feature of pro- • 120 VAC(NFS-320/NFS-320C);240 VAC(NFS-320E). gram creation and editing capability from the front panel keypad, • Displays battery current/voltage on panel (with display). while continuing to provide fire protection. The architecture of the NFS-320 software is such that each point entry carries its own program, including control-by-event links to other points. FlashScan, Exclusive This allows the program to be entered with independent per- World-Leading Detector Protocol point segments, while the NFS-320 simultaneously monitors At the heart of the NFS-320 is a set of detection devices and other(already installed)points for alarm conditions. device protocol— FlashScan (U.S. Patent 5,539,389). FlashS- VeriFire®Tools is an offline programming and test utility that can can is an all-digital protocol that gives superior precision and greatly reduce installation programming time, and increase con- high noise immunity. fidence in the site-specific software. It is Windows®-based and In addition to providing quick identification of an active input provides technologically advanced capabilities to aid the device,this protocol can also activate many output devices in a installer. The installer may create the entire program for the fraction of the time required by competitive protocols. This high NFS-320 in the comfort of the office, test it, store a backup file, speed also allows the NFS-320 to have the largest device per then bring it to the site and download from a laptop into the loop capacity in the industry—318 points—yet every input and panel. output device is sampled in less than two seconds. The micro- processor-based FlashScan detectors have bicolor LEDs that Placement of Equipment can be coded to provide diagnostic information, such as device in Chassis and Cabinet address during Walk Test. The following guidelines outline the NFS-320's flexible system design. ONYX Intelligent Sensing Wiring:When designing the cabinet layout,consider separation Intelligent sensing is a set of software algorithms that provides of power-limited and non-power-limited wiring as discussed in the NFS-320 with industry-leading smoke detection capability. the NFS-320Installation Manual. These complex algorithms require many calculations on each It is critical that all mounting holes of the NFS-320 are secured reading of each detector, and are made possible by the high- with a screw or standoff to ensure continuity of Earth Ground. speed microcomputer used by the NFS-320. Networking: If networking two or more control panels,each unit Drift Compensation and Smoothing: Drift compensation requires a Network Communication Module or High-Speed Net- allows the detector to retain its original ability to detect actual work Communication Module(HS-NCM can support two nodes; smoke, and resist false alarms, even as dirt accumulates. It see "Networking Options" on page 4). These modules can be reduces maintenance requirements by allowing the system to installed in any option board position (see manual), and addi- automatically perform the periodic sensitivity measurements tional option boards can be mounted in front of them. required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, such as those KDM-R2 Controls and Indicators caused by electrical interference. Maintenance Warnings: When the drift compensation per- Program Keypad: QWERTY type(keyboard layout). formed for a detector reaches a certain level,the performance of 12 LED Indicators: Power; Fire Alarm; Pre-Alarm; Security; the detector may be compromised, and special warnings are Supervisory; System Trouble; Signals Silenced; Points Dis- given. There are three warning levels: (1) Low Chamber value; abled; Control Active;Abort; Pre-Discharge; Discharge. (2) Maintenance Alert, indicative of dust accumulation that is Keypad Switch Controls: Acknowledge/Scroll Display; Signal near but below the allowed limit; (3)Maintenance Urgent, indic- Silence; Drill;System Reset; Lamp Test. ative of dust accumulation above the allowed limit. Sensitivity Adjust: Nine sensitivity levels are provided for LCD Display: 80 characters (2 x 40) with long-life LED back- alarm detection. These levels can be set manually, or can light. change automatically between day and night. Nine levels of pre- alarm sensitivity can also be selected, based on predetermined Product Line Information levels of alarm. Pre-alarm operation can be latching or self- "Configuration Guidelines"on page 4 restoring,and can be used to activate special control functions. "Networking Options"on page 4 Self-Optimizing Pre-Alarm:Each detector may be set for"Self- "Auxiliary Power Supplies and Batteries"on page 4 Optimizing" pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog "Audio Options"on page 4 DN-7112:M•01/25/2016—Page 3 of 6 • "Compatible Devices, EIA-232 Ports"on page 4 transfer relay,and overcurrent protection. Mounts on two of four • "Compatible Devices, EIA-485 Ports"on page 4 positions on a CHS-4L or CHS-4 chassis. See DN-5952. • "Compatible Intelligent Devices"on page 4 FCPS-24S6/S8: Remote 6 A and 8 A power supplies with bat- "Enclosures, Chassis,and Dress Plates"on page 5 tery charger.See DN-6927. • "Other Options"on page 5 BAT Series: Batteries. NFS-320 uses two 12 volt, 18 to 200 AH batteries. See DN-6933. CONFIGURATION GUIDELINES The NFS-320 system ships assembled; description and some AUDIO OPTIONS options follow. See "Enclosures, Chassis, and Dress Plates"on NFC-50/100: 25 watt, 25 VRMS, emergency Voice Evacuation page 5 for information about mounting peripherals. Control Panel (VECP) with integral commercial microphone, NOTE: Stand-alone and network systems require a main display digital message generator, and Class A or Class B speaker cir- On stand-alone systems,the panel's keypad provides the required cuits. See DN-60772. display. On network systems (two or more networked fire panel COMPATIBLE DEVICES, EIA-232 PORTS nodes), at least one NCA-2, NCS, or ONYXWorks annunciation device is required. (For NCA-2,see DN-7047.) PRN-6: 80-column printer. See DN-6956. The standard, factory-assembled NFS-320 system PRN-7: 80-column printer. See DN-60897. includes the following components: one control panel mounted VS4095/5: Printer, 40-column, 24 V. Mounted in external back- on chassis(120 V operation-ships with grounding cable, bat- box. See DN-3260. tery interconnect cables, and document kit); includes integral power supply mounted to the main circuit board; one primary DPI-232: Direct Panel Interface, specialized modem for extend- display KDM-R2 keypad/display; and one cabinet for surface or ing serial data links to remotely located FACPs and/or peripher- semi-flush mounting. Purchase batteries separately. One or two als; mount on NFS-320 chassis. See DN-6870. option boards may be mounted inside the NFS-320 cabinet; COMPATIBLE DEVICES, EIA-485 PORTS additional option boards can be used in remote cabinets. (Non- English versions also available. NFS-320-SP, NFS-320-PO.) ACM-24AT: ONYX Series ACS annunciator-up to 96 points of NFS-320R:Same as NFS-320, but in red enclosure. annunciation with Alarm or Active LED,Trouble LED,and switch NFS-320C: Based on NFS-320 above. NFS-320C supports per circuit. Active/Alarm LEDs can be programmed (by pow- installation of an optional ACM-series annunciator in the same ered-up switch selection) by point to be red, green, or yellow; cabinet. UL- and ULC-listed. (Non-English version also avail- the Trouble LED is always yellow. See DN-6862. able:NFS-320C-FR.)For NFS-320C, see DN-60085. AEM-24AT: Same LED and switch capabilities as ACM-24AT, NFS-320CR: Same as NFS-320C but in a red enclosure. For expands the ACM-24AT to 48,72,or 96 points. See DN-6862. NFS-320C, see DN-60085. ACM-48A: ONYX Series ACS annunciator-up to 96 points of NFS-320E: Same as NFS-320, but with 240 V operation. (Non- annunciation with Alarm or Active LED per circuit. Active/Alarm English versions also available.NFS-320E-SP, NFS-320E-PO.) LEDs can be programmed (by powered-up switch selection) in groups of 24 to be red, green, or yellow. Expandable to 96 TR-320:Trim ring for the NFS-320 cabinet. points with one AEM-48A.See DN-6862. NETWORKING OPTIONS AEM-48A: Same LED capabilities as ACM-48A, expands the ACM-48A to 96 points. See DN-6862. NCM-W, NCM-F: Standard Network Communications Modules. ACM-8111: Remote Relay Module with eight Form-C contacts. Wire and multi-mode fiber versions available. See DN-6861. Can be located up to 6,000 ft. (1828.8 m) from panel on four HS-NCM-W/MF/SF/WMF/WSF/MFSF: High-speed Network wires. See DN-3558. Communications Modules. Wire, single-mode fiber, multi-mode FDU-80: Terminal mode. 80-character, backlit LCD display. fiber, and media conversion models are available. See DN- Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per 60454. FACP. See DN-6820. RPT-W, RPT-F, RPT-WF:Standard-network repeater board with LCD2-80: Terminal and ACS mode. 80-character, backlit LCD wire connection (RPT-W), multi-mode fiber connection (RPT-F), display. Mounts up to 6,000 ft. (1828.8 m)from panel. Up to 32 or allowing a change in media type between wire and fiber per FACP. See DN-60548. (RPT-WF). Not used with high-speed networks. See DN-6971. ONYXWorks: UL-listed graphics PC workstation, software, and LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM-R32; computer hardware. See DN-7048 for specific part numbers. remote custom driver modules. See DN-0551. NFN-GW-EM-3: NFN Gateway,embedded. See DN-60499. SCS: Smoke control stations SCS-8, SCE-8, with lamp drivers SCS-8L,SCE-8L;eight(expandable to 16)circuits(HVAC only). NWS-3: NOTI•FIRE•NETTM Web Server. See DN-6928. See DN-4818. CAP-GW: Common Alerting Protocol Gateway.See DN-60756. TM-4: Transmitter Module. Includes three reverse-polarity cir- VESDA-HLI-GW: VESDAnet high-level interface gateway. See cuits and one municipal box circuit; mount on NFS-320 chassis DN-60753. or remotely. See DN-6860. LEDSIGN-GW: UL-listed sign gateway. Interfaces with classic UDACT-2: Universal Digital Alarm Communicator Transmitter, and high-speed NOTI•FIRE•NET networks through the NFN 636 channel. See DN-60686. Gateway. See DN-60679. UZC-256: Programmable Universal Zone Coder provides posi- OAX2-24V: UL-listed LED sign, used with LEDSIGN-GW. See tive non-interfering successive zone coding. Microprocessor- DN-60679. controlled, field-programmable from IBM coding. PCs (requires optional programming kit). Mounts in BB-UZC. See AUXILIARY POWER SUPPLIES AND BATTERIES DN-3404. ACPS-610:6.0 A or 10.0 A addressable charging power supply. COMPATIBLE INTELLIGENT DEVICES See DN-60244. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes FWSG Wireless SWIFT Gateway: Addressable gateway sup- of power for peripheral devices. Includes battery input and ports wireless SLC devices. Not appropriate for ULC applica- tions. See DN-60820. Page 4 of 6-DN-7112:M•01/25/2016 FSA-5000: Intelligent FAAST®XS Fire Alarm Aspiration Sens- FRM-1: FlashScan relay module. See DN-6724. ing Technology. Intelligent aspirating smoke detector for applica- FDRM-1: FlashScan dual monitor/dual relay module. See DN- tions up to 5,000 sq.ft. For Canadian applications, order FSA- 60709. 5000A. NBG-12LX: Manual pull station,addressable. See DN-6726. FSA-8000: Intelligent FAAST®XM Fire Alarm Aspiration Sens- ISO-X: Isolator module. See DN-2243. ing Technology. Intelligent aspirating smoke detector for applica- tions up to 8,000 sq.ft. For Canadian applications, order FSA- ISO-6: Six Fault isolator module. For Canadian applications 8000A. See DN-60792 order ISO-6A. See DN-60844. FSA-20000: Intelligent FAAST®XT Fire Alarm Aspiration Sens- XP6-C: FlashScan six-circuit supervised control module. See ing Technology. Intelligent aspirating smoke detector for applica- DN-6924. tions up to 28,800 sq.ft. For Canadian applications, order FSA- XP6-MA: FlashScan six-zone interface module; connects intelli- 20000A. See DN-60849. gent alarm system to two-wire conventional detection zone. See FSB-200: Intelligent beam smoke detector. See DN-6985. DN-6925. FSB-20OS: Intelligent beam smoke detector with integral sensi- XP6-R: FlashScan six-relay(Form-C)control module. See DN- tivity test. See DN-6985 6926. FSC-851: FlashScan IntelliQuad Advanced Multi-Criteria Detec- XP10-M: FlashScan ten-input monitor module. See DN-6923. tor. See DN-60412. SLC-IM: SLC integration module,for VESDAnet detectors. See FCO-851: FlashScan IntelliQuad PLUS Advanced Multi-Criteria DN-60755. Fire/CO Detector. See DN-60689. ENCLOSURES, CHASSIS,AND DRESS PLATES FSI-851: Low-profile FlashScan ionization detector. See DN- 6934. CAB-BM Marine System: Protects equipment in shipboard and Low-profile FlashScan photoelectric detector. See waterfront applications. Also order BB-MB for systems using DN-6935. 100 AH batteries. For a full list of required and optional equip- ment,see DN-60688. FSP-851T: Low-profile FlashScan photoelectric detector with BB-UZC: Backbox for housing the UZC-256. Required for NFS- 135°F(57°C)thermal. See DN-6935. 320 applications. Black. For red,order BB-UZC-R. FSP-851R: Remote-test capable photoelectric detector for use NFS-LBB: Battery Box (required for batteries larger than 26 with DNR(W)duct detector housings. See DN-6935. AH). FST-851: FlashScan thermal detector 135°F (57°C). See NFS-LBBR: Same as above, but red. DN-6936. FST-851R: FlashScan thermal detector 135°F (57°C)with rate- SEISKIT-320/1326: Seismic mounting kit. Required for seismic- of-rise. See DN-6936. certified applications with NFS-320 and BB-26. Includes battery bracket for two 26 AH batteries. FST-851H: FlashScan 190°F (88°C) high-temperature thermal SEISKIT-BB25: Seismic mounting kit for the BB-25. Includes detector. See DN-6936. battery bracket for two 26 AH batteries. FAPT-851: FlashScan Acclimate Plus low-profile multi-sensor SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery detector. See DN-6937. bracket for two 55 AH batteries. FSL-751: FlashScan VIEW laser photo detector. See DN-6886. DNR: InnovairFlex low-flow non-relay duct-detector housing OTHER OPTIONS (order FSP-851 R separately). Replaces FSD-751 PL/FSD- 411: Slave Digital Alarm Communicator. See DN-6619. 751 RPL. See DN-60429. 411 UDAC: Digital Alarm Communicator. See DN-6746. DNRW: Same as above with NEMA-4 rating, watertight. See IPDACT-2/2UD, IPDACT Internet Monitoring Module: Con- DN-60429. nects to primary and secondary DACT telephone output ports B224RB: Low-profile relay base.See DN-60054. for internet communications over customer-provided Ethernet B224BI: Isolator base for low-profile detectors.See DN-60054. connection. Requires compatible Teldat VisorALARM Central B21OLP: Low-profile base. Standard U.S. style. Replaces Station Receiver. Can use DHCP or static IP. See DN-60408. B710LP. See DN-60054. IPSPLT. Y-adapter option allow connection of both panel dialer B501: European-style,4"(10.16 cm)base. See DN-60054. outputs to one IPDACT-2/2UD cable input. B20OS: Intelligent programmable sounder base,capable of pro- IPENC: External enclosure for IPDACT, includes IPBRKT ducing a variety of tone patterns including ANSI Temporal 3. mounting bracket; Red. For Black order IPENC-B. Compatible with sychronization protocol.See DN-60054. IPGSM-4G: Internet and Digital Cellular Fire Alarm Communica- B200S-LF: Low-frequency version of B200S. See DN-60054. tor. Provides selectable configurable paths:cellular only, IP only, or IP primary with cellular backup. Connects to the primary and B200SR: Sounder base, Temporal 3 or Continuous tone. See secondary ports of a DACT. See DH-60769. DN-60054. NFS-320-RB: Replacement board with central processing unit B200SR-LF: Low-frequency version of B200SR. See DN- (CPU). NOTE: Keypad must be removed before shipping old 60054. unit out for repair. FlashScan monitor module. See DN-6720. NFS-320-RBE: Replacement CPU, Export. FlashScan dual monitor module. See DN-6720. NFS-320-RB-PO: Replacement CPU, Portuguese. FZM-1: FlashScan two-wire detector monitor module. See DN- NFS-320-RB-POE: Replacement CPU, Export, Portu- 6720. guese. miniature monitor module. See DN-6720. NFS-320-RBC-FR: Replacement CPU, Canadian French. FCM-1: FlashScan control module. See DN-6724. NFS-320-RB-SP: Replacement CPU, Spanish. FlashScan releasing control module. See DN- 60390. DN-7112:M•01/25/2016-Page 5 of 6 • NFS-320-RB-SPE: Replacement CPU, Export, Spanish. AGENCY LISTINGS AND APPROVALS NOTE:For other options including compatibility with retrofit equip- The listings and approvals below apply to the basic NFS-320 ment,refer to the panel's installation manual,the SLC manual,and control panel. In some cases, certain modules may not be listed the Device Compatibility Document. by certain approval agencies, or listing may be in process.Con- sult factory for latest listing status. System Specifications UL Listed: S635. SYSTEM CAPACITY ULC Listed: S635(NFS-320C only, excludes IPDACT). • FM Approved. • Intelligent Signaling Line Circuits ......................................... 1 CSFM: 7165-0028:0243. • Intelligent detectors ......................................................... 159 • MEA: 128-07-E. • Addressable monitor/control modules.............................. 159 Fire Dept.of New York:#6121. • Programmable internal hardware and output circuits ..........4 City of Chicago. • Programmable software zones...........................................99 NOTE: For additional information on UL- and ULC-listed model • Special programming zones............................................... 14 NFS-320C, see DN-60085. For information on NFS-320SYS, see • LCD annunciators per NFS-320/-320E .............................32 DN-60637. • ACS annunciators Marine Applications: Marine approved systems must be con- per NFS-320/-320E .......................32 addresses x 64 points figured using components itemized in this document. (See Main SPECIFICATIONS System Components, in "Product Line Information.) Specific connections and requirements for those components are • Primary input power described in the installation document, PN 54756. When these -NFS-320: 120 VAC,50/60 Hz, 5.0 A. requirements are followed,systems are approved by the follow- -NFS-320E:220/240 VAC,50/60 Hz,2.5 A. ing agencies: • Current draw(standby/alarm): • US Coast Guard 161.002/50/0, 161.002/55/0 (Standard 46 -NFS-320(E)board: 0.250 A.Add 0.035 A for each NAC in CFR and 161.002). use. Lloyd's Register 11/600013(ENV 3 category). -KDM-R2(Backlight on):0.100 A. American Bureau of Shipping(ABS)Type Approval. • Total output 24 V power:6.0 A in alarm. NOTE:For information on marine applications,see DN-60688. NOTE: The power supply has a total of 6.0 A of available power. STANDARDS This is shared by all internal circuits. See Installation Manual for a complete current draw calculation sheet. The NFS-320 complies with the following UL Standards and NFPA 72, International Building Code (IBC), and California • Standard notification circuits(4): 1.5 A each. Building Code(CBC)Fire Alarm Systems requirements: • Resettable regulated 24V power: 1.25 A. • Two non-resettable regulated 24V power outputs: UL UL 07 864(Fire). 107 • 6(Burglary). -1.25 A. UL 2572 (Mass Notification Systems). (NFS-320 version 20 -0.50 A. or higher). • Non-resettable 5V power:0.15 A. LOCAL(Automatic, Manual,Waterflow and Sprinkler Super- Battery charger range: 18 AH-200 AH. Use separate cabi- visory). net for batteries over 26 AH. AUXILIARY (Automatic, Manual and Waterflow) (requires • Float rate:27.6 V. TM-4). CABINET SPECIFICATIONS REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory)(requires TM-4). NFS-320 cabinet dimensions: PROPRIETARY (Automatic, Manual, Waterflow and Sprin- • Backbox: 18.12 in. (46.025 cm)width; 18.12 in. (46.025 cm) kler Supervisory). Not applicable for FM. height;5.81 in. (14.76 cm)depth. CENTRAL STATION (Automatic, Manual, Waterflow and • Door: 18.187 in. (46.195 cm) width; 18.40 in. (46.736 cm) Sprinkler Supervisory)(requires DACT). height;0.75 in. (1.905 cm)depth. EMERGENCY VOICE/ALARM. • Trim ring: Molding width is 0.905 in.(2.299 cm). OT, PSDN (Other Technologies, Packet-switched Data Net- Shipping weight(without batteries):36.15 lb. (16.4 kg). work). • IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seis- TEMPERATURE AND HUMIDITY RANGES mlc). This system meets NFPA requirements for operation at 0 - CBC 2007(Seismic). 49°C/32-120°F and at a relative humidity 93%±2% RH (non- condensing) at 32°C ± 2°C (90oF ± 3°F). However, the useful IntelliQuadTM, NOTI•FIRE•NETT", ONYXWorksT"^, and SWIFTT"^ are life of the system's standby batteries and the electronic compo- trademarks; and Acclimate® PIUST°", FirstCommande, FlashScano, nents may be adversely affected by extreme temperature Intelligent FAAST°, NOTIFIER°, ONYX°, VeriFiree, and VIEW° are ranges and humidity.Therefore,it is recommended that this sys- registered trademarks of Honeywell International Inc. Microsoft® and tem and its peripherals be installed in an environment with a Windows®are registered trademarks of Microsoft Corporation. IBM®is a normal room temperature of 15-27°C/60-80°F. registered trademark of IBM Corporation. ©2016 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 6 of 6-DN-7112:M•01/25/2016 Features r " • Out-of-the-Box Installation and Commissioning • Ultrasonic Airflow Sensing • Laser-Based Absolute Smoke Detection • Pre-engineered pipe network designs •tea • Programmable Alarm Thresholds KEn1 Q N • Clean air barrier optics protection VESOA O• • Instant Recognition Display • Instant Fault Finder TM 5 • AutoLearnTM Smoke • AutoLearnTm Flow • Field Service Access Door • Multiple Event Logging in separate logs • Event log—up to 18000 events • Offline/online configuration capability The Xtralis VESDA VLF-500 detector is a very early warning smoke • Up to 500 m2(5000 sq.ft.)coverage* detector designed to protect small, business-critical environments of less than 500 mz (5000 sq. ft.) The detector works by continually drawing air into sampling holes in a pipe Listings/Approvals network. The air is filtered and passed into a detection chamber where light • UL scattering technology detects the presence of very small amounts of smoke. . ULC Detector status information is communicated on the detector display and via relays or optional interface cards. FM • CFE Out-of-the-box operation • LPCB The VLF can be installed and commissioned out-of-the-box without the need • VdS for a special interface or software programming tools. • VNIIPO In operation, the unique Smoke Dial display provides the user with an instant . AFNOR understanding of a smoke event, even from a distance. Should a fault occur, the user simply opens the field service door and activates the Instant Fault ActivFire Finder feature to determine the specific fault condition. This information • CE- EMC and CPD can then be passed onto their fire service company, ensuring that service • EN 54-20 technicians arrive onsite fully prepared. Class A(30 holes/0.05%obs/m) Class B(30 holes/0.15%obs/m) Ultrasonic Flow Sensing Class C(30 holes/0.32%obs/m) The patent-pending Ultrasonic Flow Sensing used in the VLF provides a Classification of any configuration is direct reading of the sampling pipe flow rate. The system is immune to air determined usingASPIRE2. temperature and pressure changes and is unaffected by contamination. The Regional approvals listings and regulatory compliance vary between VLF is the first air sampling smoke detector to use ultrasonic flow sensing. Xtraliproduct approvals msVEB�Aprom tmodels.Refer to www.xtralis.com forthe latest prodatrix. VESDA XtralisI F -11 VESDA 11 Specifications hin Display Input Power The display provided to the user includes a Voltage: 24V DC Nominal(18-30 V DC) Smoke Dial and alarm and status indicators. Current @ 24 VDC: 410 mA nominal,490 mA in alarm Dimensions(W x H x D) 255 mm x 185 mm x 90 mm(91/8 in x 71/8 in x 31/2 in) Weight Approx.2 kg(4.4 Ibs) 11 IP Rating IP30 Mounting Upright,inverted or horizontal O �, Operating Conditionsr Ambient: 0°C to 39°C(32°F to 103°F)* ! VESDA O Tested to: -100C to 550C(140F to 131OF)* Sampled Air: -200C to 600C(320F to 104°F)* Humidity: 5%to 95%RH,non-condensing Sampling Network Maximum pipe lengths: 1 x 50 m(150 ft) (Max.24 holes) 2 x 30 m(90 ft)per branch(Max. 12 holes per branch) Sampling Hole Options: Pre-Engineered Option or Maximum Pipe length in accordance with Pipe Modelling Design Tool(ASPIRE2T"") When the field service access door is open, the user has access to the RESET(5, Air Inlet Pipe DISABLE Q, Fire Test® ,AutoLearn�� Accepts both metric and American standard pipe sizes. and Instant Fault Finder functions. Metric:25 mm American Pipe: IPS'/4 in. When the Instant Fault Finder function is activated,the Smoke Dial converts to a fault Area Coverage indicator,with the dial segment numbers Up to 500 m2(5000 sq.ft.)depending on local codes and standards corresponding to the faults listed below. Relay Outputs 3 changeover relays(Fire 1,Action, Fault),Contacts rated 2A @ 30 VDC(max). NO/NC Contacts Legend of fault indicators Cable Access 1 Filter 6 External Device/PSU 3 x 25 mm(11/16 in.)cable entries(1 rear entry,2 top entry) 2 Aspirator 7 Interface card Cable Termination 3 High flow 8 Field wiring Screw Terminals 0.2-2.5 mm2(30-12 AWG) 4 Low flow 9 AutoLearn Fail Interfaces 5 n/a 10 Detector failure Shown in Terminal Block Connections diagram,to right, plus an RS232 Programming Port. General Purpose Input(GPI)interface offers:Reset, Disable,Standby,Alarm set 1,Alarm set 2 and External Input functions. Terminal Block Connections Alarm Threshold Setting Range 1 GPI Alert,Action, 0.025-2.00%obs/m(0.008-0.625%obs/ft) 2 GPI Fire 1, Fire 2 0.025-20.00%obs/m(0.008-6.25%obs/ft) 3 Display TX Individual Alarm Delays 0—60 seconds 4 Display RX Two Alarm Threshold Settings Either time or GPI based 5 Display Common Ground Display 6 Display Power- •4 Alarm State Indicators •Fault and Disabled Indicators 7 Display Power+ •Smoke Level Indicator •Instant Fault Finder 8 Power Return 0 VDC From power •Reset, Disable and Test Controls •Smoke and Flow AutoLearn Controls 9 Power In 24 VDC supply unit Event Log 10 Power Return 0 VDC To next detector Up to 18000 events,time and date stamped in separate,non-volatile,logs for: (if more than 1 detector Smoke Level, Flow Level,Detector Status and Faults 11 Power Out 24 VDC per Power Supply Unit) 12 NC AutoLearn Smoke&Flow 13 Common Fault relay •Automatically set acceptable alarm thresholds for both smoke and flow levels 14 NO •Minimum 15 minutes, maximum 15 days(default 14 days) 15 NC •During AutoLearn,thresholds are NOT changed from pre-set values 16 Common Action relay Warranty Period 17 NO 2 years 18 NC Ordering Information: 19 Common Fire 1 relay VLF-500-00 Xtralis VESDA VLF. European language set. English display labels 20 NO VLF-500-01 Xtralis VESDA VLF. European language set. International display labels VLF-500-02 Xtralis VESDA VLF. English+Asian language set. International display labels Approvals Compliance VLF-500-04 Xtralis VESDA VLF. English+Russian language set. International display labels VLF-500-05 Xtralis VESDA VLF. English+Eastern Euro language set. International display labels Please refer to the Product Guide for details VIC-010 VESDAnet Interface Card regarding compliant design,installation and VIC-020 Multifunction Control Card(MCC) commissioning. VIC-030 Multifunction Control Card(MCC)with Monitored Powered Output(MPO) Product UL listed for use from 0°C to 38*C(32°F to 104*F) VSP-005 Filter Cartridge,VSP-715 Aspirator for VLF-500 www.xtralis.com The Americas+1 781 740 2223 Asia+852 2916 8894 Australia and New Zealand+61 3 9936 7000 Continental Europe+32 56 24 19 51 UK and the Middle East+44 1442 242 330 Zl The contents of this document are provided on an"as is"basis.No representation or warranty(either express or implied)is made as to theX =✓ completeness,accuracy or reliability of the contents of this document.The manufacturer reserves the right to change designs or specifications without obligation and without further notice.Except as otherwise provided,all warranties,express or implied,including without limitation any implied warranties of merchantability and fitness for a particular purpose are expressly excluded. VESDA This document includes registered and unregistered trademarks.All trademarks displayed are the trademarks of their respective owners. Your use of this document does not constitute or create a licence or any other right to use the name and/or trademark and/or label. This document is subject to copyright owned by Xtralis AG("Xtralis").You agree not to copy,communicate to the public,adapt,distribute,transfer, sell,modify or publish any contents of this document without the express prior written consent of Xtralis. *Depending upon local codes and standards}Operation outside these parameters will reduce detector life. Doc.no.10046 14 Part:20298 Permit#: 3549 Permit Date: 11/16/20 Permit Type: FIRE SPRINKLER Project Name: PUD Applicant Name: Suppression Systems Inc. Applicant Address: 3077 20th Street E, Suite B Applicant, City, State, Zip: Fife,WA 98424 Contact: Nina Reeves Phone: 253-926-3300 Email: nina@suppression.com Scope of Work: Fire Suppression for Modular Data Unit Valuation: 700.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 03/25/2021 Permit Expires: 09/21/2021 Form Permit Type: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31052200400200 17601 59TH AVE NE PUBLIC UTILITY 489 Other Utilities DISTRICT NO 1 NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License# Suppression Systems Inc Nina Reeves 253-926-3300 3077 20th Street CONSTRUCTION Labor E,Suite B CONTRACTOR Industri and es SUPPRSI044RR Plan Reviews Date Review Type Description Assigned To Review Status 11/16/2020 FIRE SPRINKLER BUILDING 11/16/2020 FIRE SPRINKLER 1.Drawings and calculations for the clean agent system Mike Makela Approved shall be signed and/or stamped by an individual with either an appropriate NICET Level III certification or Washington Professional Engineer(P.E.)license. 2.Drawings and calculations for the VESDA smoke detection system shall be signed and/or stamped by an individual with either an appropriate NICET Level III certification or Washington Professional Engineer(P.E.) license. 3.Drawings and calculations for the remaining fire alarm system shall be signed and/or stamped by an individual with either an appropriate NICET Level III certification or Washington Professional Engineer(P.E.)license. 4.A single permit application can be completed for this project;however the total valuation used shall include that of all three systems(clean agent,VESDA,and fire alarm) and any additional site work to be completed once the Modular Data Center is placed on site. Fire Alarm/VESDA 1.Permit and set of approved plans to remain on site during installation.Installers shall present NICET 11 certification upon request. 2.Battery load test required,switch system to battery operation 24-hours prior to final inspection.Notification appliances to operate for 5 minutes on battery power. 3.Trouble condition to be verified for initiation, notification and signaling circuits. 4.Furnish a written statement to the Arlington Fire O1/11/2021 FIRE SPRINKLER Department stating that the system has been installed in FIRE accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). Clean Agent System 5.Functional acceptance test to be witnessed by AHJ and comply with NFPA 2001 Section 7.7. The record of completion forms for each system shall be submitted prior to project close-out. Fees Fee Description Notes Amount Processing/Technology $25.00 Fire System Plan Review Table 4-1 $100.00 Fire Alarm System Permit NFPA 72- 105.7.3 $300.00 Credit Card Service $12.75 Total $437.75 Attached Letters Date Letter Description 03/22/2021 Building Permit O1/12/2021 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 03/24/2021 Ben Davis 85633689 $425.00 03/24/2021 Ben Davis Transaction $12.75 85633689 Outstanding Balance $0.00 Notes Date Note Created By: 03/25/2021 Emailed the pennit for signature. Kristin Foster O1/21/2021 Emailed Nina for the separate valuations as Mike and I discussed. Kristin Foster O1/12/2021 Need to calculate the plan review fees based on the valuation-reach out to Nina. Kristin Foster 11/16/2020 Contractor needs out of city license prior to issuance.Emailed the application. Kristin Foster Uploaded Files Date File Name 10/04/2021 9820196-3549 IC 6.6.2021.pdf 03/25/2021 8411180-3549 Issued Pennit.pdf 12/09/2020 7816670-PUD Clean Agent Suppression System Additional Requirements.pdf 11/16/2020 7704664-3549 PUDFIRE+SUPPRESSION+DRAWINGS+10-29-20.pdf 11/16/2020 7704665-3549 Apnlication.pdf Date: 03/30/2026 Permit#: 3549 Permit 11/16/2020 Date: Review 01/11/2021 Date: Permit FIRE SPRINKLER Type: Review FIRE SPRINKLER Type: Target Date: 01/18/2021 Scheduled 00:00 Time: Completed 01/11/2021 Date: Description: Fire Alarm/VESDA 1. Permit and set of approved plans to remain on site during installation. Installers shall present NICET 11 certification upon request. 2. Battery load test required, switch system to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for initiation, notification and signaling circuits. 4. Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). Clean Agent System 5. Functional acceptance test to be witnessed by AHJ and comply with NFPA 2001 Section 7.7. The record of completion forms for each system shall be submitted prior to project close-out. Review Status: Assigned FIRE To: Time In: 00:00 Time Out: 00:00 Hours: 1.5 Review Items 01.Application Requirements Notes Fire Alarm/VESDA 1. Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request. 2. Battery load test required, switch system to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for initiation, notification and signaling circuits. 4. Furnish a written statement to the Arlington Fire Department stating that the system has O1/12/2021 been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). Clean Agent System 5. Functional acceptance test to be witnessed by AHJ and comply with NFPA 2001 Section 7.7. The record of completion forms for each system shall be submitted prior to project close-out. Fire Alarm/VESDA 1. Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request. 2. Battery load test required, switch system to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for initiation, notification and signaling circuits. 4. Furnish a written statement to the Arlington Fire Department stating that the system has 03/22/2021 been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). Clean Agent System 5. Functional acceptance test to be witnessed by AHJ and comply with NFPA 2001 Section 7.7. The record of completion forms for each system shall be submitted prior to project close-out. Property Information Parcel#: 31052200400200 PUBLIC UTILITY DISTRICT NO 1 PUBLIC UTILITY DISTRICT NO 1 PO BOX 1107 17601 59TH AVE NE EVERETT,WA 98206 Zoning: 489 Other Utilities NECLot: Block: Date: 03/30/2026 Permit#: 3549 Permit 11/16/2020 Date: Review 11/16/2020 Date: Permit FIRE SPRINKLER Type: Review FIRE SPRINKLER Type: Target Date: 11/30/2020 Scheduled 00:00 Time: Completed 12/09/2020 Date: Description: 1. Drawings and calculations for the clean agent system shall be signed and/or stamped by an individual with either an appropriate NICET Level III certification or Washington Professional Engineer(P.E.) license. 2. Drawings and calculations for the VESDA smoke detection system shall be signed and/or stamped by an individual with either an appropriate NICET Level III certification or Washington Professional Engineer(P.E.) license. 3. Drawings and calculations for the remaining fire alarm system shall be signed and/or stamped by an individual with either an appropriate NICET Level III certification or Washington Professional Engineer(P.E.) license. 4. A single permit application can be completed for this project; however the total valuation used shall include that of all three systems (clean agent,VESDA, and fire alarm) and any additional site work to be completed once the Modular Data Center is placed on site. Review Status: Assigned Mike Makela To: Time In: 00:00 Time Out: 00:00 Hours: 1.0 Review Items 01.Application Requirements Notes 1. Drawings and calculations for the clean agent system shall be signed and/or stamped by an individual with either an appropriate NICET Level III certification or Washington Professional Engineer(P.E.) license. 2. Drawings and calculations for the VESDA smoke detection system shall be signed and/or stamped by an individual with either an appropriate NICET Level III certification or O1/11/2021 Washington Professional Engineer(P.E.) license. 3. Drawings and calculations for the remaining fire alarm system shall be signed and/or stamped by an individual with either an appropriate NICET Level III certification or Washington Professional Engineer(P.E.) license. 4.A single permit application can be completed for this project; however the total valuation used shall include that of all three systems (clean agent,VESDA, and fire alarm) and any additional site work to be completed once the Modular Data Center is placed on site. Property Information Parcel#: 31052200400200 PUBLIC UTILITY DISTRICT NO 1 PUBLIC UTILITY DISTRICT NO 1 PO BOX 1107 17601 59TH AVE NE EVERETT, WA 98206 Zoning: 489 Other Utilities NECLot: Block: Permit#: 3549 Permit Date: 11/16/20 Permit Type: FIRE SPRINKLER Project Name: PUD Applicant Name: Suppression Systems Inc. Applicant Address: 3077 20th Street E, Suite B Applicant, City, State, Zip: Fife,WA 98424 Contact: Nina Reeves Phone: 253-926-3300 Email: nina@suppression.com Scope of Work: Fire Suppression for Modular Data Unit Valuation: 700.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 03/25/2021 Permit Expires: 09/21/2021 Form Permit Type: Status: LASERFICHE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31052200400200 17601 59TH AVE NE PUBLIC UTILITY 489 Other Utilities DISTRICT NO 1 NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License# Suppression Systems Inc Nina Reeves 253-926-3300 3077 20th Street CONSTRUCTION Labor E,Suite B CONTRACTOR Industri and es SUPPRSI044RR Plan Reviews Date Review Type Description Assigned To Review Status 11/16/2020 FIRE SPRINKLER BUILDING 11/16/2020 FIRE SPRINKLER 1.Drawings and calculations for the clean agent system Mike Makela Approved shall be signed and/or stamped by an individual with either an appropriate NICET Level III certification or Washington Professional Engineer(P.E.)license. 2.Drawings and calculations for the VESDA smoke detection system shall be signed and/or stamped by an individual with either an appropriate NICET Level III certification or Washington Professional Engineer(P.E.) license. 3.Drawings and calculations for the remaining fire alarm system shall be signed and/or stamped by an individual with either an appropriate NICET Level III certification or Washington Professional Engineer(P.E.)license. 4.A single permit application can be completed for this project;however the total valuation used shall include that of all three systems(clean agent,VESDA,and fire alarm) and any additional site work to be completed once the Modular Data Center is placed on site. Fire Alarm/VESDA 1.Permit and set of approved plans to remain on site during installation.Installers shall present NICET 11 certification upon request. 2.Battery load test required,switch system to battery operation 24-hours prior to final inspection.Notification appliances to operate for 5 minutes on battery power. 3.Trouble condition to be verified for initiation, notification and signaling circuits. 4.Furnish a written statement to the Arlington Fire O1/11/2021 FIRE SPRINKLER Department stating that the system has been installed in FIRE accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). Clean Agent System 5.Functional acceptance test to be witnessed by AHJ and comply with NFPA 2001 Section 7.7. The record of completion forms for each system shall be submitted prior to project close-out. Fees Fee Description Notes Amount Processing/Technology $25.00 Fire System Plan Review Table 4-1 $100.00 Fire Alarm System Permit NFPA 72- 105.7.3 $300.00 Credit Card Service $12.75 Total $437.75 Attached Letters Date Letter Description 03/22/2021 Building Permit O1/12/2021 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 03/24/2021 Ben Davis 85633689 $425.00 03/24/2021 Ben Davis Transaction $12.75 85633689 Outstanding Balance $0.00 Notes Date Note Created By: 03/25/2021 Emailed the pennit for signature. Kristin Foster O1/21/2021 Emailed Nina for the separate valuations as Mike and I discussed. Kristin Foster O1/12/2021 Need to calculate the plan review fees based on the valuation-reach out to Nina. Kristin Foster 11/16/2020 Contractor needs out of city license prior to issuance.Emailed the application. Kristin Foster Uploaded Files Date File Name 10/04/2021 9820196-3549 IC 6.6.2021.pdf 03/25/2021 8411180-3549 Issued Pennit.pdf 12/09/2020 7816670-PUD Clean Agent Suppression System Additional Requirements.pdf 11/16/2020 7704664-3549 PUDFIRE+SUPPRESSION+DRAWINGS+10-29-20.pdf 11/16/2020 7704665-3549 Apnlication.pdf ORIA%va City of M 0 ,It�' T I � Fire Department December 9, 2020 Permit Number: BLD 3549 Project Address: 17601 59t" Avenue NE, Arlington Project Description: Fire Plans for Snohomish PUD Modular Data Center Contractor: Nina Reeves Suppression Systems Inc. 3077 20th Street E, Suite B Seattle, WA 98108 Re: Fire Suppression Shop Drawing Review Comments The Arlington Fire Department is attempting to complete a review of the Fire Suppression shop drawing submittal for the clean agent/VESDA/fire alarm system proposed for the Modular Data Center to be installed at their North Snohomish County location. The following is required to be submitted in order to complete the review and approval of the plans: 1. Drawings and calculations for the clean agent system shall be signed and/or stamped by an individual with either an appropriate NICET Level III certification or Washington Professional Engineer (P.E.) license. 2. Drawings and calculations for the VESDA smoke detection system shall be signed and/or stamped by an individual with either an appropriate NICET Level III certification or Washington Professional Engineer (P.E.) license. 3. Drawings and calculations for the remaining fire alarm system shall be signed and/or stamped by an individual with either an appropriate NICET Level III certification or Washington Professional Engineer (P.E.) license. 4. A single permit application can be completed for this project; however the total valuation used shall include that of all three systems (clean agent, VESDA, and fire alarm) and any additional site work to be completed once the Modular Data Center is placed on site. Items noted above are required to be submitted to the City of Arlington before the plan review can be completed. If there are any questions please do not hesitate to call. Sincerely, K& Mike Makela Assistant Fire Chief Arlington Fire Department 6231 188t'StreetArlington, ' •i 61 1 •11 61 1 • • • ••