Loading...
HomeMy WebLinkAbout127 E DIVISION ST_BLD3545_2026 1y •� FIRE SPRINKLER PERMIT APPLICATION ItNIGV Department of Community & Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF COMPLETE AND SCALED PLANS, TWO (2) SETS OF HYDRAULIC CALCULATIONS, TWO (2) SETS OF EQUIPMENT SPECIFICATIONS FOR EACH FIRE SPRINKLER PERMIT APPLICATION. INCLUDE ELECTRICAL PLANS WHERE APPLICABLE. ALSO INCLUDE SPECIFICATION SHEETS, WIRING DIAGRAMS (POINT TO POINT WIRING), AND ALL OTHER INFORMATION ON ALL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION. Type of Permit: ❑ New Fire Sprinkler ❑ Fire Sprinkler Add/Alt ❑ Underground Fire Line 127 E DIVISION ST Project Address: Parcel ID#: Project Valuation: 1786.00 Number of Heads: 9 Building Area(Sq Ft): NA Owner: THE FOUNTAIN Phone Number: (360) 435-6601 Address: 127 E DIVISION ST City:ARLINGTON State: WA Zip Code: 98223 Contact Person:Nisha Taylor Phone Number: 3607555444 Cell Phone: 360-610-9682 Email: taylorn@pyebarkerfire.com Address: 735 E Fairhaven Ave City: Burlington State: WA Zip Code:98233 Contractor: Pye Barker Fire Phone Number: 3607555444 Address: 735 E Fairhaven Ave City: Burlington State: Washin Zip Code:98233 Contractor's License Number: PYEBASF807DO Expiration:03-20-2022 Contact Person: N isha Taylor Email:taylorn@ pyebarkerfire.com hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accordance with the laws,rules and regulation of the State of Washington. e,es=3oeo,9eseeoe =ea4�eoa�d 11/06/2020 Applicants Signature Date NISHA A TAYLOR Print Applicants Name FOR STAFF USE ONLY Permit# Accepted By Amount Received Receipt# Date Received WEB Forms—131 Page 1 of 1 6116LP W J 01 9 A W N ..ZZ DD1D2�1D V11�D Z M Mr-r- 3m DmCDNrM1 ;ory Oro Nmc7mpaprmar-dp err mm dM-rr4mp�r 3r-I MZOMMGa �rmz,mr �mm�pm rr� _ M rl �6zpmmmrnm as A aaAcvr jadm> aaw<m O3 C3:>0;0--1 �DonmZ-U-UO U-im Z-4�zN>m N z2 DD?�m DDmmdy<D mDD�.T�7 mm Dy'8-'w>ucA O NZ =£Z+rm dd�N=D�3zmm m�-<r,za-I'NpD •� dEJ 01 Dn O=D�D Ao C Dr r-ZNw£tn X2>zC3 SpNr 3 mr -433Wc M ---I Gdp�mlz � "-M --Iwm 6 mazrrrm DmS-4mm'�AmS p Lz-1z Mu To -i x anm-A XA�moC3�mCom m w_0 z��C-)0 4 iD pCoiZ -4 rM-u>-MM"XqumN m AZ-OM ZDm pp>"w M mm<-4 zC Ao_nmoo> rp 0-4 r-m amNm�1 -13-48'- pmp w pcom <r c� eyDm�n4ir6tlAm� N3C W mm m� C�mr x m�=� � ZDmXZO ZS 33zDmA3D N Z IDD £ �1zDm° �Xzp Cl O X m � NCXAmt7 c: -0� N >> zC ZA � c3mZmu -4mo � N ZM . p Z r M:--I r°dCdV1 D� ���cZr�ci '� p�md���mo rwr M-U rty*1ZC�m rA 3D=N<oDD m -4zWM2MmMM m \� tC W tyMSyr N�ODC �m timmz--g!lm*�r C 4mDq-Mts% 3 � 0 �; D.-Z -4 MM 3> �� rm*1D rDjN3p D� N N{rQr+r V1mOD fMMMFMP a7 Ll m-u M2-1 Z r=�� z%W m ggwmu• 4cy d�mma aarr m NaNN wM AmtymooN G N o Z 3k iPDpmm �p mn3m�-1Zn .y. 93D o-1 �O 1D Nv N Vo <5DM-1 mZ gO>>WAyZ z T D AN Hm Z ci70 x - - �F oS cy�eyid�m zm ��aZmmz� czi s� 00 m �{ wO mHD mD D nC�frTl�l��-' D m z3 z X -ter AA m�`"�dzoz 3 A ty DX < D ZO --- -�E- mmi2 Ay rymDur- Z;o D ti p rm '1 y ry �� 27-45•�1 roC �-<v 0 vmmm-4p z � aA m � C X,C7 No DC AXCpp 0 t7 r .y. M; 3 m 0 TI N� -0A1 C� AZ < x Z c G� Z Z _ - _ p.�+0 pr*7 Ll GD 2 S L'1 r Dm p RT- cn vzi�? rNi� pin C3 m c D D OS LZl and Zm cS DN - 1 m Zz z tim ra p e ZA z m p c � Ll rm N V32 '\ Cr.-�c-�o rn vi X v) -i � �3 �z-n£ri o as o 00 0� o c c 00 r^1 �' 5 c m r-;�'M twd owd z � � wrn e� � ZMWtj £ £ £ OM OMrOrm£ � -4m VZ N IT'I N� D zZNr. nM 000 M � mNoZ� � � N•� p�m N VJ rn rn .'-- •"- •= •"- o N N = o 0 � f(Z'��- _ _ ri*tOrZi .Z10Z1'lM� D r C. X X X X W o r x N £ TI XMo 70 O>G�I�IDJ Z�ru DZ£ MM--I�r- M.G r m N N N D 0 Gt7.�1'�Ip��J1 dam.. t7�X ���Zr� £ t7 W OD W OD 0 c7 M r*I O rn M G 3-�-I f'1 O ml Q° UDtl C �� L mt:j v7 f�^/y rn r x c . . . . r- Cam �ntlrv'z m u w �, �, �, �, D C C d N m .Z �� --IMM w n -0 -0 rN- r 70 m. C-) D NClW r�r.£ DD-U=rD w m m f'l nmm=r � 15' -u> �Zt7 Z"`n�m+rr Aw -Z ZLTI��- ��.mN COr�L)Z O m O f"7ADnL) C� 0=Z ��� rZ��£�--' fU rU CD N N r-zxr U 3 C 1 �ir+M C C�7 �7rrz,VG rim���m rn m m < -iZDr a v, M o H skri."s-4um F,rc Atpwrtw��'t M ND y N D M rn rV R) rU N M '"' "" r M ,�, o �`- z M mD a N d PROJECT L r*t r M m° m a M" W. z41.1. THE FOUNTAIN MEIeER w pw aNMEIt twE SAFEtY �r ~ 11 735 E FAIRHAVEN, BURLINGTON WAa , ��e ARLINGTON, WA 98223 360-755-5444 7DO '-M>'MmD r City of Arlington 7�tlNG � Fire Department November 16, 2020 Permit Number: BLD 3545 Project Address: 127 E Division Street, Arlington Project Description: Hood Suppression System Plans for the Fountain Contractor: Pye Barker Fire PO Box 265 Burlington, WA Re: Fire Suppression Shop Drawing Review Comments/Approval The Arlington Fire Department has completed a review of the Hood Suppression System shop drawing submittal and approves the issuance of the permit with the following conditions: Permit Conditions: 1. Permit and set of approved plans to remain on site during installation. 2. Plans indicate the bottom of hood measures approximately 89 inches above floor. The Hoodmart Installation, Operation and Maintenance Manual indicates that typical canopy hood hanging height is 78 inches, but that actual hood hanging height requirements are given on the UL label on the hood. The hood will be required to be installed at the height listed on the UL label AND the suppression system acceptance test successfully witnessed by the City of Arlington prior to final approval given. 3. Final test and inspection witnessed by City of Arlington shall consist of the following: i. Orientation of nozzles shall be verified with the use of a nozzle aiming device. ii. A nozzle cap blow-off test shall be conducted. iii. Signage shall be provided on the exhaust hood or system cabinet, indicating the type and arrangement of cooking appliances protected by the automatic fire-extinguishing system. Signage shall indicate appliances from left to right, be durable, and the size, color, and lettering shall be approved. iv. As there is not a fire alarm system installed in the building, an audible or visual indicator shall be provided to show that the system has operated, that personnel response is needed, and that the system is in need of recharge per NFPA 17A, Section 5.2.1.8. A horn strobe shall be installed to meet this requirement. v. Installation certification form to be completed and submitted. Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the system at project completion. Final approval will not be provided until all conditions are verified. Call at least 48 hours in advance to schedule inspections. If there are any questions please do not hesitate to call. Sincerely, & Mike Makela Assistant Fire Chief Arlington Fire Department OFFICE C NOTICE vl- TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY O APPROVED PERMIT#: A �!5 ❑ AM ❑ PM DATE: JOB ADDRESS: 1 (�_v,;, -� 'i LOT#: PROJECT: ! h-k;: t=' ,� .'.;•..� TYPE OF INSPECTION: OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. Cl CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THEACTIONS OR CORRECTIONS INDICATED ABOVEARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE �<v o ell ❑PLANNING [ICIVIL ElBUILDING CITY OF ARLINGTON :, ' CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT Permit#:3545 127 E DIVISION ST Permit Expiration Date: 05/12/2021 Parcel#: 00461800702000 Valuation: 1786.00 OWNER APPLICANT CONTRACTOR EOFF FRED R Pye Barker Fire Pye Barker Fire 127 E DIVISION ST 735 E Fairhaven Ave PO Box 265 ARLINGTON,WA 98223 Burlington,WA 98223 Burlington,WA 98233 360-755-5444 360-755-5444 LIC:PYEBAFS807DO EXP:03/20/2022 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Sprinkler CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRCI10. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. O Signature rint Name Date Released By ate CONDITIONS 1.Permit and set of approved plans to remain on site during installation.2.Plans indicate the bottom of hood measures approximately 89 inches above floor.The Hoodmart Installation,Operation and Maintenance Manual indicates that typical canopy hood hanging height is 78 ii ;s,but that actual hood hanging height require its are given on the UL label on the hood.The hood will be required to be installed at the height listed on the UL label AND the suppression system acceptance test successfully witnessed by the City of Arlington prior to final approval given.3.Final test and inspection witnessed by City of Arlington shall consist of the following: i. Orientation of nozzles shall be verified with the use of a nozzle aiming device.ii.A nozzle cap blow-off test shall be conducted. iii. Signage shall be provided on the exhaust hood or system cabinet,indicating the type and arrangement of cooking appliances protected by the automatic fire-extinguishing system. Signage shall indicate appliances from left to right,be durable,and the size,color,and lettering shall be approved.iv.As there is not a fire alarm system installed in the building,an audible or visual indicator shall be provided to show that the system has operated,that personnel response is needed,and that the system is in need of recharge per NFPA 17A,Section 5.2.1.8.A horn strobe shall be installed to meet this requirement.v.Installation certification form to be completed and submitted. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/16/2020 Fire Sprinkler Permit $175.00 11/16/2020 Processing/Technology Fee $25.00 11/16/2020 Fire System Plan Review $100.00 Total Due: $300.00 Total Payment: $0.00 Balance Due: $300.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT Permit#:3545 127 E DIVISION ST Permit Expiration Date: 05/12/2021 Parcel#: 00461800702000 Valuation: 1786.00 OWNER APPLICANT CONTRACTOR EOFF FRED R Pye Barker Fire Pye Barker Fire 127 E DIVISION ST 735 E Fairhaven Ave PO Box 265 ARLINGTON,WA 98223 Burlington,WA 98223 Burlington,WA 98233 360-755-5444 360-755-5444 LIC:PYEBAFS807DO EXP:03/20/2022 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Sprinkler CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law, or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By ate CONDITIONS 1.Permit and set of approved plans to remain on site during installation.2.Plans indicate the bottom of hood measures approximately 89 inches above floor.The Hoodmart Installation,Operation and Maintenance Manual indicates that typical canopy hood hanging height is 78 inches,but that actual hood hanging height requirements are given on the UL label on the hood. The hood will be required to be installed at the height listed on the UL label AND the suppression system acceptance test successfully witnessed by the City of Arlington prior to final approval given.3.Final test and inspection witnessed by City of Arlington shall consist of the following: i. Orientation of nozzles shall be verified with the use of a nozzle aiming device.ii.A nozzle cap blow-off test shall be conducted. iii. Signage shall be provided on the exhaust hood or system cabinet,indicating the type and arrangement of cooking appliances protected by the automatic fire-extinguishing system. Signage shall indicate appliances from left to right,be durable, and the size,color,and lettering shall be approved.iv.As there is not a fire alarm system installed in the building,an audible or visual indicator shall be provided to show that the system has operated,that personnel response is needed,and that the system is in need of recharge per NFPA 17A,Section 5.2.1.8. A horn strobe shall be installed to meet this requirement.v.Installation certification form to be completed and submitted. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/16/2020 Fire Sprinkler Permit $175.00 11/16/2020 Processing/Technology Fee $25.00 11/16/2020 Fire System Plan Review $100.00 Total Due: $300.00 Total Payment: $0.00 Balance Due: $300.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection, allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon NOTES, 300 LISTED - FIRE SUPPRESSION SPECIFICATIONS1, ALL ELECTRICAL & GAS TO SHUT OFF UPON SYSTEM ACTIVATION, EXHAUST FAN TO U.L. �PYE•BARKER ACTIVATE UPON SYSTEM ACTIVATION �s,ee•�•Fscer iic 2. LIGHTS UNDER HOOD MUST HAVE EXPLOSION PROOF GLASS COVERS. KIDDE WHDR260/260 WET CHEMICAL FIRE SUPPRESSION SYSTEM 3. SEE MANUFACTURES SPECS FOR PRE-ENGINEERED FIRE SUPPRESSION SYSTEM PIPING LIMITATIONS, ALL PIPING TO BE BLACK IRON SCHEDULE 40 HAZARD NOZZLE FLOW PTS QTY TOTAL PTS 4. PULL STATION TO BE LOCATED ALONG PATH OF EGRESS 10' TO 20' MAX FROM KITCHEN DUCT 12x12 ADP 1 1 1 APPLIANCES, MOUNTED ON WALL 42-48' ABOVE FINISHED FLOOR, MANUAL ACTIVATION DEVICE SHALL CLEARLY IDENTIFY THE HAZARD PROTECTED DUCT 12x12 ADP 1 1 1 ¢ a 5. FIXED PIPE SYSTEMS IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTANEOUS 3 A AUTOMATIC OPERATION UPON ACTUATION OF ANY ONE SYSTEM PLENUM 10-0" ADP 1 1 1 z o 6. 'K' TYPE FIRE EXTINGUISHER TO BE MOUNTED WITHIN 20' OF APPLIANCES ALONG PATH OF o 00 EGRESS 48' GRIDDLE 48x24 ADP 1 2 2 H a 7. MAKEUP AIR UNIT TO BE INTERLOCKED WITH FIRE SUPPRESSION SYSTEM AND EXHAUST FAN, I qr IF PRESENT 24' FRYER 11,5x18 F 2 1 2 _J qr w 8, ALL APPLIANCES ON WHEELS SHALL HAVE 'PIG-TAIL' GAS CONNECTIONS, DOUBLE POT a 9. ALL APPLIANCE WITH NOZZLE COVERAGE MUST HAVE MARKINGS ON FLOOR SO THE 11,5x18 F 2 1 2 PAu�ae APPLIANCE CAN BE RETURNED TO ITS ORIGINAL POSITION AFTER CLEANING. 24" FRYER 11,5x18 F 2 1 2 2 In 10. IF FIRE ALARM IS PRESENT FIRE SUPPRESSION SYSTEM IS TO BE TIED INTO ALARM PANEL. Ld > i 11. UPON ACTIVATION OF AUTOMATIC FIRE-EXTINGUISHING SYSTEM AN AUDIBLE OR VISUAL DOUBLE POT 11,5x18 F 2 1 2 a INDICATOR SHALL BE PROVIDED TO SHOW THAT THE SYSTEM HAS ACTIVATED M 12. A PLACARD SHALL BE CONSPICUOUSLY PLACED NEAR EACH CLASS K FIRE EXTINGUISHER TOTAL FLOW POINTS USED = 13 a u THAT STATES THAT THE FIRE PROTECTION SYSTEM SHALL BE ACTIVATED PRIOR TO USING TOTAL FLOW POINTS ALLOWED = 16 THE FIRE EXTINGUISHER TOTAL FLOW POINTS AVAILABLE = 3 13, SPLASH GUARD TO BE PROVIDED BETWEEN ANY FRYER AND OPEN FLAMES, MUST EXTEND 8' a ABOVE HAZARD AREA, EXCEPTION 16' HORIZONTAL SPACE BETWEEN FRYERS AND OPEN SCOPE OF WORK: SUPPLY & INSTALL KIDDE LINK H❑USING FLAMES, KITS, KIDDE CORNER PULLEYS, ALL NEW STAINLESS 14. HIGHEST TEMPERATURE RATING TO BE ESTABLISHED AT TIME OF FINAL INSPECTION, STEEL CABLE, CORRECT NOZZLE HEIGHTS, INSTALL APPROPRIATE FUSIBLE LINK TO BE DETERMINED BY ALPINE FIRE & SAFETY CERTIFIED TECHNICIAN, IN A MANNER TO AVOID UNWANTED DISCHARGE OR A DELAYED RESPONSE IN SWIVEL NOZZLES ON FRYER DROPS, CORRECT PLACEMENT ACCORDANCE WITH MANUFACTURES MINIMUM AMBIENT TEMP RATINGS, OF DUCT NOZZLE, CORRECT ACTUATI❑N LINE 15. A PICTOGRAPH OF THE APPROVED PLAN SHALL BE POSTED & VISIBLE C❑NFIGURATI❑N. PERFORM SEMI ANNUAL SERVICE DUCT DUCT CERTIFICATI❑N NOTE: 12x12 EXISITNG 12x12 NEW XV ALL MECHANICAL CONTROL M COMPONENTS ARE EXISTING ADP TYPE 1 10'-0 HOOD ADP HEAD CIAH❑❑D MART# 77703 F=9z==l F=9z==9 FUSIBLE LINKS ADP 0 10'-0" I� ADP ADP FI FI (2) KIDDE WHDR260 Q SYSTEM CYLINDERS w W Z °�° I I I I INDIVIDUALLY PIPEDCIA [� 6' MIN I I Iq- L 6" MIN �- I I Ir" I u I I I I L4 OD MANUAL PULL STATI❑N Ord LOCATED ALONG PATH a s o 0 0 0 OF EGRESS 10-20' FROM TITLE: HAZARD OR AN AHJ 42-48' APPROVED L❑CATI❑N SUPPRESSION SSIONS S 48' GRIDDLE REVISION sloNSYSTEM REVISION ( ) FRY POTS DEFERRED SUBMITTALS: DATE 115'x18 INCL JDING 11/6/2020 • BUILDING • MECHANICAL SCALE, • FIRE ALARM 3/8"= • FIRE SPRINKLER SHEET, 4'-0" 2'-0" 2'-0" • ELECTRICAL 1 OF 1 WET CHEMICAL SYSTEM - INSTALLATION MANUAL yC}O C e t Unk tmusi ki vent plug Wire steave 11.6 mm Wire -PU NY r TermobtA onarPUNY F-Nozzle stainless w~.F steal piping Xv Control system Manual wire release staiid s steel Idgh pr—re pull type itxvument nbe.114"(6 nnt) 1 l litre L4,7 ylinder HDR-125 AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 1 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL CHAPTER 4 INSTALLATION 4-1 INTRODUCTION This chapter is intended tar system installers. It outlines the steps needed to install the Kiddeg Wet Chemical Fire Suppression System. 4-2 GENERAL INSTALLATION REQUIREMENTS All components shall be installed in accordance with the appropriate NFPA standard: • Extinguishing system per NFPA 17A and NFPA 96 • Detection and alarm control units ;other than detectors) per NFPA 72, • Electrical connections per NFPA 70, • This Design, Installation, Operation, and Maintenance Manual IDIOM) (P/N 87 122000 001), and • Local Authority (laving Jurisdiction (Ali]). Only factory trained and authorized personnel are permitted to install or maintain Kidde Fire Systems Wet Chemical fire suppression systems. 4-3 INSTALLATION OF SUPPRESSION 1. Install the mounting brackets to hold the Cylinder and Valve Assembly. For wall mounting, see Paragraph 4 3.1. For floor mounting, see Paragraph 4 3.2. 2. Mount the Cylinder and Valve Assembly on mountinq brackets. 3. Install agent distribution piping. 1. Install nozzles. 4-3.1 Wall Mounting Bracket Installation, P/N 60-9197430-000, 60-9197263-000, 60-9197414-000, 60-9197415-000, 87-100013-001 The Wall Mounting Bracket is to be mounted vertically ;plumb, with the Cylinder and Valve Assembly in the upriqht position. The mounting location shall be in a clean, dry and protected area where the ambient temperature is between 01'F ; 18"C) and 120"F (490C) and sufficiently away from the hazards) so as not to be exposed to process or fire temperatures in excess of 120"F 1490C). The bracket must be mounted in such a way that no part of the assembly stands in water or other liquid. The Cylinder- and Valve Assembly should be mounted at least 4 inches (102 mm) above the floor. 1. Determine the Wall Mounting Bracket mounting locations and mark the mounting holes for each bracket. When mounting to a wall stud, use the two in line vertical holes in the bracket back. If mounting to a hood, use the two horizontal holes in the bracket back. Before drilling the mounting holes, be sure that the mounting surface will support the loads identified in Table 4 2. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 2 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 2. Drill three holes for each Mounting Bracket and attach the bracket to the mounting surface with three (3) 3/8-inch diameter bolts or screws of suitable length and type. Use of other approved hardware is permitted. A~I y1 IrL j � (19 MM)� I-am h t. D �Isr mmlr Dili 'i unrnnnlunlfn IIIIIIIIIIIIIIIr111r11 11I11111111111111 MIIWIvrN I 1 ( D th C ( Iq h � RS MM) 7 }'- 42 Y►;' E E (64 MM) I IO F i- .��� - C� WNDR 125 �WNDR26a 400K GENERAL WHDR BRACKET and 4003 BRACISFT BRACT DWENSIDNS Figure 4-1. Wall Mounting Bracket Table 4-1. Wall Mounting Bracket Specifications Wall Mounting Model Dimensions Bracket P/N A B C D E F G 60 9197430 000 WHDR 125 3 in. 9 3/8 in. 1 3/8 in. 2 in. 3 1/4 in. 3 3/8 in. WHDR-5EU (76 mm) (238 mm) (35 mm) (51 mm) (83 mm) (86 mm) 60-9197263-000 WHDR-260 4 1/2 in. 12 in. 2 1/2 in. 3-1/2 in. 3-3/4 in. 3 in. 5 1/4 in. WHDR-10EU (114 mm) (305 mm) (64 mm) (89 mm) (95 mm) (76 mm) (133 mm) 60-9197414-000 WHDR-400M 4-1/2 in. 20-1/2 in. 2-1/2 in. 3-1/2 in. 13-1/4 in. 2 in. 11-1/4 in. WHDRM15EU (114 mm) (521 mm) (64 mm) (89 mm) (337 mm) (51 mm) (286 mm) 60-9197415-000 WHDR-400S 4-1/2 in. 11-1/2 in. 2 in. 3-1/2 in. 3-3/4 in. 4-1/4 in. 4-1/4 in. WHDR-S15EU (114 mm) (290 mm) (51 mm) (89 mm) (95 mm) (108 mm) (108 mm) 87-100013-001 WHDR 600 WHDR 400 See Figure 4-2 WIIDR 23EU Table 4-2. Wall Mounting Bracket Wall Support Load Wall Mounting Bracket P/N Model Wall Support Load 60 9197430 000 WHDR 125 43 1b. (19.4 kg) 60-9197263-000 WHDR-260 80 1b. (36 kg) 60-9197414-000 WHDR-400M 132 1b. (60 kg) 60-9197415-000 WHDR-400S 132 1b. (60 kg) 87-100013-001 WHDR-600 and WHDR-400 225 lb. (102 kg) AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 3 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-3.3 Cylinder and Valve Assembly Installation Upon removal of each Cylinder and Valve Assembly from its shipping carton, carefully check the following: 1. Ensure that the Anti-Recoil Plate and the Valve Protection Plate are secured to the valve. VALVE PROTECTION PLATE ANTI-RECOL PLATE VALVE AND CYLINDER ASSEMBLY Figure 4-4. Anti-Recoil and Valve Protection Plates The Anti-Recoil Plate must remain installed on the valve outlet at all times © except when the cylinder is mounted to a properly secured mounting bracket. The Protection Cap must remain on the valve until the System Valve Actuator WARNING (SVA) is installed. Refer to the Safety Summary for more information on pressurized cylinders. 2. Check that the cylinder pressure is within the acceptable range shown on the pressure gauge. If not, replace with a properly charged cylinder. 3. Inspect the Cylinder and Valve Assembly for any signs of damage such as dents, nicks or scratches. Refer to Compressed Gas Association (CGA) pamphlet C-6 for cylinder inspection procedures. 4. Place each Cylinder and Valve Assembly on its bracket shelf, tighten the cylinder strap and check the mounting for proper fit. Make any necessary final adjustments. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 4 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-3.4 Installing the Discharge Adapter Kit, P/N 844908 1. Remove the cylinder Anti-Recoil Plate. Do not discard. 2. Lubricate the 0-ring with a light coating of Parker Super-O-Lube. Do not grease the bonded seal on valve check. Place the 0-ring in the groove near the inlet end of the Discharge Adapter. 3. Insert the Discharge Adapter through the hole in the flange plate (see Figure 4-5). 4. Install the Discharge Adapter into the valve outlet. 5. Install the two 5/16-18 x 1-inch bolts through the cylinder valve and flange adapter and tighten. Each Cylinder and Valve Assembly must be installed in an upright position using the Mounting Bracket specified in Table 4-1 and Table 4-3. Each Cylinder and Valve Assembly will also utilize a Discharge Adapter Kit (P/N 844908). NUT 5/16-18 SHIPPING CAP NUT 5116-18 O-RING DISCHARGE ADAPTER 0 c FLANGE PLATE :- -- -" BOLTS 5/16-18 X 1 In.LONG CYLINDER AND VALVE ASSEMBLY Figure 4-5. Installing the Discharge Adapter Kit, P/N 844908 AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 5 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-3.5 Installation of Pipe/Tubing and Fittings 4-3.5.1 AGENT DISTRIBUTION PIPING Note: If a Pressure Operated Release (P/N 60-9189412-000) is to be used, refer to Paragraph 4-3.5.3. If a Pressure Switch (P/N 60-9197023-000) is to be used, refer to Paragraph 4-3.5.2. Install the agent distribution piping as defined in Chapter 3, or enclosures being protected. Note: Use of bushings is permitted. QDo not exceed the maximum pipe lengths, equivalent pipe lengths or pipe fitting CAUTION parameters as defined in Chapter 3 or the system may not operate as intended. Piping may be Schedule 40, black steel, or stainless steel. All fittings shall be a minimum of 150 lb. class. Examples of acceptable fitting materials include malleable iron, ductile iron or stainless steel compression or stainless steel flare types. Couplings and unions may be used where necessary, and reducing bushings or reducing tees can be used for changes in pipe diameter. Refer to NFPA 17A, latest edition. Galvanized pipe and fittings are not permitted. CAUTION Pipe hangers or pipe clamps shall be used for support as required. Refer to local plumbing codes for piping requirements. Do not use water or oxygen to blow out piping. Moisture will cause blockage. © The use of oxygen is very dangerous as the possible presence of even a minute WARNING quantity of oil may cause an explosion, thereby causing death, serious personal injury and/or property damage. Before installing the agent distribution piping, ensure that the inside of the pipe is clean and free of obstructions. Piping shall be reamed and cleaned before assembly. After the piping is installed, it must be blown clean with dry air or nitrogen. Pipe thread compound or tape shall not be used. Refer to NFPA 17A, latest edition. Avoid low points or "traps" in the pipe work that would allow liquid to accumulate. In addition, all pipe should pitch toward the cylinder or toward a nozzle so that liquid can drain after a discharge or after flushing. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 6 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL When using stainless steel tubing, the following minimum bend radii must be maintained: Table 4-4. Tubing Radius .035 Wall Stainless Steel Tubing Minimum Bend Radius, R 3/8 in. (9.5 mm) 15/16 in. (24 mm) 1/2 in. (13 mm) 1-1/4 in. (32 mm) 5/8 in. (16 mm) 1-1/2 in. (38 mm) 7/8 in. (22 mm) 2 in. (51 mm) 1 in. (25 mm) 3 in. (76 mm) — --- I � I � I � I R I � I ti I � l I I I I STAINLESS STEEL TUBING I I I Figure 4-6. Stainless Steel Tubing AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 7 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-3.5.4 VENT PLUG, P/N 60-9196984-000 The vent plug has a 1/2-inch (13 mm) NPT and can be installed in the outlet or the run of the tee in the discharge pipe. In all systems requiring multiple cylinder systems, only one vent plug is required. The vent plug must always point up or horizontally, never down, to assure that it will remain open during discharge. Note: It is necessary to use a bushing with the vent plug when installing the vent plug in a tee larger than 1/2-inch (13 mm). Figure 4-9. Vent Plug, P/N 60-9196984-000 4-3.6 Installing Nozzles QDo not use teflon tape or pipe compound when installing nozzles. Refer to NFPA CAUTION 17A. eThe nozzles are made of brass. Use a 13/16 open-end or adjustable wrench and CAUTION tighten until snug. Do not overtighten. Note: Ensure nozzle caps are installed on the nozzles. Do not overtighten or foil seals will be damaged. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 8 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-4 INSTALLATION OF CONTROLS 4-4.1 XV Control System Installation Remove the XV Control System from its shipping carton. AUse care when removing the knockouts as you can damage the XV Control CAUTION System enclosure. Q Ensure that the knockout pieces of the mounting holes do not remain inside the XV Control System (P/N 87-120099-001) enclosure. Failure to remove these CAUTION could cause malfunction of the mechanism. Identify the knockouts that will be used for cable connections to the XV Control System enclosure. It is easiest if these knockouts are removed before mounting the XV Control System enclosure. Refer to Figure 4-10 for knockout designations. Note: If using more than the three EMT connectors supplied with the XV Control System, you must use EMT Connector and O-Ring Kit, P/N 87-120058-001. KNOCKOUT) (DET MON LM 2) (OPTION 1)-SEE NOTE KNOCKOUT? (OET EC TIO N LINE 11 KNOCKOUTS :R EN OT E MAN UAL RELEASE) :DETECTION LINE 21 :OPTION 21-SEE NOTE KNOCKOUT2 (SWITCH LEAD FOR DEEP MOUNT NICROSWITCHESIZ- RELL EASE LOEAL SE UAL KNOCKOUT? :NOT USED) ZKNOCKOUT KNOCKOUTS 1 , ECHANICALWI M TCH LEAD GAS VALVE) FOR HIGH NOU hT VKNOCKOUTS NICROSWITCHES) FOR NOU NTI NG ACTUATION XV TO SVA (OUTPUT)PORT Figure 4-10. Pipe Connection Knockout Designations Note: If using Detection Line 2, select Detection Line 2 (Option 1) OR Detection Line 2 (Option 2). You cannot use both Detection Line 2 knockouts. Note: The knockouts are an integral part of the housing. Ensure that only required knockouts are broken out. Planning ahead and opening only the knockouts necessary for the system will help in keeping the box sealed from dirt, grease, water and other contaminants. • If wall mounting, refer to Paragraph 4-4.1.1. • If cylinder mounting, Paragraph 4-4.1.2. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 9 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-4.1.1 INSTALLING THE XV CONTROL SYSTEM (WALL MOUNT) 1. With the XV Control System cover removed, lay the box on its back. Locate the four mounting holes in the housing. Position the box so that the mounting holes are not flat on the work surface and break out the knockouts. See Figure 4-11 for location of mounting holes. MOUNTING MOUNTING HOLE 5-112 In. HOLE (140 mm) O) (194 mm) GA -- 314 In. ®) 0 I (19 mm) ( MOUNTING 4-3/8 In. HOLE (112 mm) MOUNTING 1-5/16 In. HOLE (34 mm) Figure 4-11. Location of Mounting Holes (Housing) 2. Using 1/4-20 x 3-inch long toggle bolts or equivalent hangers, mount the box to the wall making sure it is level. Attach the conduit fittings and other fittings to the box. Run cables and wiring as normal, within the parameters of the XV Control System. See Paragraph 4-7.1.4.1 for cable parameters. 3. Locate the System Valve Actuators (SVA). 4. Ensure the Spring Loaded Plunger of the SVA is in the 'Set' position. See Figure 4-12. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 10 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL I I I - I SVA PISTON IN SET POSITION Figure 4-12. SVA in 'Set' Position 5. Remove the Valve Protection Plate from the top of the cylinder valve. 6. Install the SVAs onto each cylinder valve (the spring loaded plunger facing cylinder valve). Do not tighten them as they will be removed at a later time. 7. Install 1/8-inch NPT pipe plug (P/N 877810) on last SVA (end of line). 8. Install 1/8 NPT (M) x 1/4 copper tubing adapters. Compression type adapters are permissible. 9. Measure and install the 1/4 O.D. x 0.031 wall thickness copper tubing. A 2-1/2 inch (64 mm) loop between each cylinder and on the inlet tubing is recommended, but not required. See Figure 4-13. Ensure that each connection is secure. 0 0 0 PW��dm PLUG� 1 Figure 4-13. Example of Copper Tubing Loop Method 10.Remove the SVAs from the cylinder valves and re-install the Valve Protection Plates. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 11 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-4.1.4 MECHANICAL DETECTION INSTALLATION 4-4.1.4.1 Installing Detection Components 1. Drill holes as necessary for installation of the Quick Seal Adapters (P/N 2649930X) or Compression Seal Adapters (P/N 2650460X). 2. Mount the detector brackets as required. WA©NG Be sure mounting penetrations are liquid tight. 3. Install conduit from the XV Control System detector conduit knockout(s) (top or right side of the XV Control System) to the detector brackets using Corner Pulleys (P/N 844648) at all changes in direction. 4. Remove screws and covers from the Corner Pulleys and set aside for reuse later. Note: No bends or offsets are permitted in conduit lines. Be sure the system is adequately supported. Acc ble W.�� Figure 4-21. Unacceptable Cable Configuration 5. Run the 1/16-inch Control Cable from the various system devices, through 1/2-inch EMT conduit, to the XV Control System. 6. Install detectors of proper rating as described in Paragraph 3-2.4. To install detectors, use the following steps. Always start detector installation at the last detector (see Figures 4-22 and 4-23). AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 12 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 7. To install detectors, create a cable loop using a Crimp Sleeve (P/N 214951), and Crimp Tool (P/N 253538). EXAMPLE OF IN-UNE DETECTOR HOUSING KIT 'S"HOOKS V 1!16 in.CABLE "S"HOOKS __----- TO XV CONTROL 1-1!2 SYSTEM 1.38 ffwn) (NOT SUPPLIED! --JCRIMP EXAMPLE OF END-OF-LINE SLEEVE DETECTOR HOUSING KIT Figure 4-22. Detector Housing Kit Installation, P/N 804548 © Use of a crimp tool besides P/N 253538 can cause malfunction and/or WARNING unwanted discharge of the system. Note: In order to ensure the crimp sleeve is secure, the cable must always be looped so that there are two lengths of cable inside the Crimp Sleeve before crimping. Cable must not be spliced anywhere along its length. 8. Place the Crimp Tool on the end of the sleeve. Ensure the flat of the sleeve rests in the saddle of the Crimp Tool jaw. Secure the sleeve in the tool carefully to ensure the sleeve does not shift in the saddle before pressing. 9. Squeeze the handles of the Crimp Tool until the tool releases itself. The tooth of the jaw is pressing on the wall of the sleeve without cracking the malleable copper. The first crimp is complete. 10.Remove the crimp from the tool. 11.Put the Crimp Tool onto the other end of the sleeve. The sleeve shall be 180: turned in the tool from the first crimp. Note: This is pressing the loop end of the sleeve (opposite that of the first press). 12.Squeeze the handles of the Crimp Tool until the tool releases itself. The tooth of the jaw is pressing on the wall of the sleeve without cracking the malleable copper. The second crimp is complete. 13.Remove the crimp from the tool. Q To ensure proper system operation, each detector must be installed so that at least 1-1/2 inches of cable movement toward the XV Control System is CAUTION maintained. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 13 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 14.Attach an "S" hook (P/N 87-9189413-000) to the end of the last detector mounting bracket. 15.Attach proper detector onto the "S" hook. 16.Attach 1/16-inch cable to the hook at the other end of the detector, forming a cable loop held in place by a Crimp Sleeve. 111 Sin.CABLE TO CONTROL SYSTEM (NOi SUPPLIED) "S"HOOKS CRIMP SLEEVE i EXAMPLE OF END-OF-LIME UNNERSAL HOUSING KIT SPACING REQUIREMENTS �• '` XV 1-W in.(38 mm)MIN. KRS-50:3 in.(76 mm)MIN. CRMIP SLEEVE EXAMPLE OF IN-LINE "S"HOOK UNIVERSAL HOUSING KIT Figure 4-23. Universal Link Housing Installation AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 14 of 41 WET CHEMICAL SYSTEM _ INSTALLATION MANUAL 4-4.1.4.3 Cabling Detection Line 1 On|y -- lndudesLochoutofDetecUon Line � 3 2 3A a 5 4 Figure 4-26. XKvvith Detection Line 2 Locked Out Table 4-6. Cabling Detection Line 1 Only Item Description 1 Lockout screw pad ',shown with one red lockout screw removed) 2 Actuation Latch 3 Spring and beam for Detection Line 2 (locked out) 3A Spring Post for Detection Line 2 (spring removed) 4 Spring and bearn for Detection Line 1 (set with cable) 4A Spring Post for Detection Line 1 5 Beam Stop for Detection Line 1 6 Beam Stop for Detection Line 2 7 Lockout pad for Detection Line 1 (not used, line set) 8 Lockout pad for Detection Line 2 (red lockout screw inserted) 1. Ensure that nothing is armed or set in the XV. 3. With the ){V completely disarmed, remove the spring from its respective post (item 3A, Detection Line 2). It is permissible to remove the spring from the detection beam. 3. Push the detection beam (item 3) against its respective beam stop (item G). 4. Using a 9/64-inch aUen key (hex) remove one of the red lockout screws from storage pad (item 1) and carefully thread into lockout pad (item 8). AUTRON[CA FIRE AND SECURITY AS oIvzSz0m MAnzTzMs - SPzxxsSTAo Page 15of41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-4.1.� ATTACHING MICROSWITCHES, P/N 87-120039-001 4-4.1.5.1 High Mounted Microswitch The High Mounted Microswitch mounts with the paddle(s) facing up into the Cam/Flag. When in the 'Set' position, the Cam/Flag pushes down on the paddle(s) of the microswitch. When the Cam/Flag is released, the microswitch(es) release and change position (see Figure 4-29 for mounting, and Figure 4-32 for wiring diagram). The microswitches are best mounted when the system is in the 'Released' position. Two pairs of #4 screws are included with each microswitch kit: 5/8-inch long and 1-inch long x 3/32-inch Allen Key. If mounting a single switch, use the 5/8-inch screws. If mounting two switches, use the 1-inch long screws. After mounting the microswitch, turn the Cam/Flag to the 'Set' position to ensure the paddles move far enough down to change the phase of the microswitch. Use the included pigtail assembly to connect the microswitch to the circuit being monitored. See Figure 4-34 to see the terminal type microswitch positions when the XV Control System is in the Set and Released states. Note: It is recommended that the pigtails be threaded into the port before attempting to plug it onto the microswitch contacts. All splices and connections should be made in a separate approved electrical box connected by EMT or other approved conduit. See NFPA 70 and 72 for proper wiring guidelines. 17 c� O 0 100 l .' C HIGH MOU T HIGH MOUNT MICROSIMTCH MICROSIMTCH RELEASED POSITION SET POSITION Figure 4-29. High Mount Microswitch, 'Released' and 'Set' Positions AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 16 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-4.1.5.2 Deep Mounted Microswitch When setting the Cam/Flag, make sure the trigger pin turns under the e microswitch paddle(s) and pushes up to set the microswitch. If the trigger pin is"above" or between the paddle and the microswitch, the microswitch will not CAUTION change position upon actuation of the XV Control System which could result in system malfunction. The Deep Mounted Microswitch mounts with the paddle(s) facing down, away from the Cam/Flag and trigger. When in the'Set' position,the trigger pin pushes up on the paddle(s) of the microswitch. When the Cam/Flag is released, the microswitch(es) release and changes position. See Figure 4-30 for mounting information. See Figure 4-32 for wiring diagram. The microswitches should be mounted when the system is in the'Released' position. Two pairs of 4 screws are included with each microswitch kit: 5/8-inch long and 1-inch long x 3/32-inch Allen Key. If mounting a single microswitch, use the 5/8-inch screws. If mounting two microswitches, use the 1-inch long screws. After mounting the microswitch, turn the Cam/Flag to the 'Set' position to ensure the paddles move far enough up to change the position of the microswitch. Use the included pigtail assembly to connect the Microswitch to the circuit being monitored. See Figure 4-34 to see the terminal type microswitch positions when the XV Control System is in the Set and Released states. Note: It is recommended that the pigtails be threaded into the port before attempting to plug it onto the microswitch contacts. All splices and connections should be made in a separate electrical junction box connected by EMT or other approved conduit. See NFPA 70 and 72 for proper wiring guidelines. Mounting the microswitch with the pigtails attached and inserted into the outlet is recommended. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 17 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL RELEASED POSITION SET POSITION �4 CI 0 Q G U 40 i ?I � 0 0 _ o o _ DEEP MOUNT DEEP MOUNT MICROSWITCH MICROSWITCH rdw 11� Figure 4-30. Deep Mount Microswitch, 'Released' and 'Set' Positions AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 18 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-4.1.6 WIRING MICROSWITCHES ELE C TRICA L CONNECTOP. RED LACK WCMVW CH h Figure 4-31. Microswitch Kit, P/N 87-120039-001 Table 4-9. Electrical Ratings for Microswitch Kit, P/N 87-120039-001 125/250 Vac 20.5 Amps 250 Vac 1.5 IiP 125 Vac 1/2 HP RED OPEN BLACK CLOSED WHITE COMMON SWITCH POSITION WHEN XV CAM/FLAG IS IN 'SET' (ARMED) POSITION Figure 4-32. Position of Switch in Set Position AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 19 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-4.4 Optional Equipment Installation 4-4.4.1 INSTALLING REMOTE MANUAL RELEASE, P/N 875572 (XV ONLY) The Remote Manual Release is equipped with a safety pin and seal wire which must be removed to permit installation of the control cable from the XV Control System. Note: The Remote Manual Release is optional if the XV Control System (local manual release) is in a clearly visible, easily accessible, unobstructed location. If it is not, a Remote Manual Release must be used for mechanical systems. Install the Remote Manual Release as outlined in Steps 1 through 6 (see Figure 4-50). 1. Mount the Remote Manual Release at a means of egress, on a clear, unobstructed exit location no more than 42-inches from the floor. The cable can enter the handle from the side hole in the snap-out cover or from the rear of the handle. If the cable is to enter from the rear, perform alternate Steps 1-a and 1-b, otherwise, proceed to Step 2. a. Drill a hole in the wall opposite the position of the Remote Manual Release handle plug (when mounted). b. Attach a 1/2-inch EMT adapter to the hole in the wall. 2. Mount the back plate to the wall using mounting hardware of required length. 3. Remove the Corner Pulley covers to aid in installing the 1/16-inch steel cable through the system. 4. Feed the 1/16-inch steel cable through the Remote Manual Release through 1/2-inch conduit or EMT to the XV Control System. Use Corner Pulleys (P/N 844648) for all changes in direction. Leave at least 12-inches of 1/16-inch steel cable coming out of the Remote Manual Release. Note: The Remote Manual Release cable attaches to the latch of the XV Control System. The Remote Manual Release uses Port 5 of the XV Control System. 5. There is a through hole in the end of the actuation latch. Carefully feed the control cable through the hole in the actuation latch. Note: It is important that the control cable slips easily through the hole in the end of the actuation latch. The actuation latch must be able to operate without interference from the control cable. Later, the movement of the actuation latch assembly will be tested before completing the setting of the XV Control System. Approximately 1-1/4 inches (32 mm) of control cable (with crimp end not included) should be left under the actuation latch, when in the 'Released' position. 6. Slip a Crimp Sleeve (P/N 214951) over the end of the control cable. 7. Making a loop, slip the end back through the Crimp Sleeve. 8. Use the Crimping Tool (P/N 253538) to fasten the Crimp Sleeve to the control cable. 9. Cut the loop off of the crimped cable assembly. Cut any loose ends off as close to the Crimp Sleeve as possible. 10.If a second Remote Manual Release is required, use the Tee Pulley assembly (P/N 843791). AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 20 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL REMOTE MANUAL RELEASE Ll (KNOCKOUT 5) REMOTE MANUAL C� RELEASE CABLE ACTUATION LATCH Ar --=1-= i,o 1-1!4 in. (32 mm) 0 o CRW CO) Ll Figure 4-50. Remote Manual Release with Detection Lines 1 and 2 Locked Out AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 21 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-4.4.1.1 Attaching Remote Manual Release Note: You can use two Remote Manual Releases with a Tee Pulley (P/N 843791) going to the XV Control System. CABLE NUT NAMEPLATE SAFETY PIN ' a , ♦�� ® MOUNTING PLATE ,.dHOUSING ti 5 1n.(127 corn) I mo• CHAIN ;\ { #10 FILLISTER HEAD SCREW ` PULL HANDLE Figure 4-51. Exploded View of the Remote Manual Release 1. Attach a length of 1/16-inch steel cable to the Remote Manual Release handle, as follows (refer to Figure 4-52): a. Unscrew the cable nut from the Remote Manual Release plug. b. Thread the cable through the cable nut hex-head end at least 3-4 inches from the entry of the Remote Manual Release box. Return the cable through the other hole of the cable nut hex- head. C. Screw the cable nut into the Remote Manual Release handle plug until tight. Insert the Remote Manual Release handle plug in the hole in the Remote Manual Release handle assembly. d. Cut excess slack where it emerges from the second hole in the hex-head end of the cable nut. e. Line up the holes in the Remote Manual Release handle and the Remote Manual Release handle plug and insert the safety pin to hold the plug in place. Loosely wrap the seal wire around the release handle to lock. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 22 of 41 WET CHEMICAL SYSTEM — INSTALLATION MANUAL 2. Attach the cover with nameplate to the mounting plate using the 2 screws provided. 3. Reattach Corner Pulley covers. �1/2 in. EMT i 112 i o.BAT 3.314 i in. (95 mm) DIA. 1 in. (25 DIA. HOLE MOUNTING HARDWARE �(57 2.V4 in. 2.114 in 1 in. mm) 1 in. k57mm) (25 mm) (25 mm) MIN. MI N. Figure 4-52. Installing the Remote Manual Release, P/N 875572 AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 23 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-6 COMMISSIONING THE SYSTEM - XV CONTROL SYSTEM Perform the "Post-Installation Checkout" on page 4-68. 4-6.1 Arming the System Set the detection beams by turning the ratchet spools counterclockwise (see Figure 4-67). Tighten the line until the beam reaches the Stop. Do not overti hl n. Note: In long cable lines (over 125 ft. [38 m]) there will be stretch in the control cable and in the loops for the detectors. It is important to ensure the control cable is tight without over tightening. QThe actuation latch must be in the horizontal position. If it is in any positior CAUTION other than horizontal, the system could malfunction. THROUGH HOLE IN RATCHET SPOOL.DETECTION LINE 2 T HROUCf1 HOLE IN RATCHET IYi SPOOL,DETECTION LINE 1 0 - �I' r 'Ld Q _ DETECTION BEAMS IN RELEASED POSITION 0 10� ACTUATION LATCH IN ••^ HORIZONTAL(SETI POSITION DETECTION BEAMS IN SET POSITION Figure 4-67. Setting the Detection Beams AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 24 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL BEAM STOPP FOR DETECTION BEAM STOP O LINE 2 FOR DETECTION LINE 1 o G O DETECTION ARM �1 DETECTION ARM Figure 4-68. Detection Beam Stops If the Remote Manual Release control cable is interfering with the free movement of the actuation latch, it might require re-cabling. If there is Osomething else interfering with the free movement of the actuation latch, take CAUTION appropriate corrective action. If it is determined that the interference is due to a mechanical fault of the XV Control System, it must be replaced and returned to the factory. Be careful not to allow the control cable to become entangled with any other parts in the system. If it does, perform the following steps. 1. Using a 7/8-inch socket (or equivalent), slightly turn the ratchet spool counterclockwise. Do not turn so far that it will click into the next step. Using the thumb release on the pawl, release the ratchet and allow it to turn backwards. The beam will move back to the 'Released' position. PAWL VERTICAL BEAM BEAM STOP RATCHET SPOOL BEAM I; STOP !!_' HORIZONTAL BEAM I PAWL - RATCHET SPOOL Figure 4-69. View of Ratchet Spool and Pawl 2. Untangle the control cable and guide it onto the spool while ratcheting. Once there is tension, there should be no more entanglement. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 25 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL When the two tensioned lines are set, the actuation latch will automatically fall into a horizontal position. Twist the Cam/Flag 90° clockwise until it clicks into place. The actuation latch will move up, then reset into the horizontal position (see Figure 4-72). Install Keeper Pin (P/N 60-9197108-000) in the Cam/Flag. o ACTUATION LATCH PORT FOR 1A in. SOCKET DRIVE (TO SET CAWFLAG) KEEPER PIN Figure 4-72. Latch Shown in "Set' Position AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 26 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-6.1.1 CHECKING MICROSWITCHES Check to ensure that the microswitches are set. The Cam/Flag should hold down the High Mount Microswitch paddles. The trigger pin should hold up the Deep Mounted Microswitches. Gently push the microswitch paddles toward the body of the microswitches. If there is a "click," the microswitch is not adjusted properly in the XV Control System. Make appropriate adjustments. The trigger pin on the Deep Mounted Microswitches must be underneath the e paddle(s) of the microswitch. If the paddle is under the trigger pin, the CAUTION microswitch will not change position upon actuation of the XV Control System and the paddle(s) might be bent or broken upon such actuation. O; G r) 40 C>; HIGH MOUNT J HIGH MOUNT MICROBIMTCH MICROSWCH RELEASED POSITION SET POSITION Figure 4-73. High Mount Microswitch, 'Released' and 'Set' Positions AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 27 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL RELEASED POSITION SET POSITION Ll It tt r i� ("off_ (g) 1140 V DEEP MOUNT DEEP MOUNT LA MICROSWITCH MICROSWITCH C�J no:) � �q lV Figure 4-74. Deep Mount Microswitch, 'Released' and `Set' Positions AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 28 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-6.2 Functional Testing of the XV Control System System Perform the "Post-Installation Checkout on page 4-68. 4-6.2.1 TEST MECHANICAL LINK LINES FOR THE XV CONTROL SYSTEM (IF APPLICABLE) To test the mechanical detector lines, perform the following steps. The mechanical detector lines are under tension. Wearing safety glasses and gloves 0 is required during this process. CAUTION Before cutting a detector, ensure the System Nitrogen Cartridge is not installed in the XV Control System and the Keeper Pin is in place in the Cam/Flag. 1. Remove the Keeper Pin (P/N 60-9197108-000) from the Cam/Flag. 2. Go to the far end of the detection line. Cut the detector. 3. Check to ensure the rotation of detection spool and beam assembly as intended. 4. Check to ensure the Cam/Flag has rotated to the 'Release' position. 5. Check the microswitches to ensure that they have changed phase as intended. 6. Check the gas valve line to ensure that it has moved freely and that the gas valve has closed. Verify that all gas fired appliances have shut down, including the pilot lights. 7. Check each detector and bracket to ensure the travel distance of the cable. Make sure the line has operated without interference at any place in the system. 8. Replace detector that was cut. 9. Reset detector line. 10.Check and ensure the actuation latch is reset back to the horizontal position. Reset the Cam/Flag. 11.Insert Keeper Pin into Cam/Flag. 12.Reset all electrical shut-offs. Repeat steps 1 through 12 for second detection line, if applicable. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 29 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL + TEST REMOTE MANUAL RELEASE, P/N 875572 (IF APPLICABLE) Q Before testing the Remote Manual Release, ensure the System Nitrogen Cartridge is not installed in the XV Control System and remove the Keeper Pin CAUTION from the Cam/Flag. 1. Operate the Remote Manual Release by pulling the safety pin located on the release handle and then pulling on the handle. 2. Observe the length of control cable that comes out of the Remote Manual Release. It should be between 3 and 4 inches (76 and 102 mm). 3. Insert the release handle back into the Remote Manual Release. It is important that the control cable slips easily through the hole in the end of the actuation latch. The actuation latch must be able to operate without interference efrom the control cable. Be sure to test the movement of the actuation latch assembly CAUTION before completing the setting of the XV Control System. 1-1/4 inch (32 mm) to 1-1/2 inch (38 mm) of control cable (with crimp end not included) should be left under the actuation latch, when in the 'Released' position. 4. Go to the XV Control System and check to ensure the Crimp Sleeve is against the bottom of the actuation latch and the actuation latch is pulled up at approximately two o'clock position and Cam/Flag is in the'Release' position. 5. Pull 1-1/2-inches of control cable back into the XV Control System. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 30 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 4-6.3 Actuation Test For the XV Control System 1. After ensuring that the system is in the 'Set' position and the Keeper Pin is in place, locate the Test Cartridge (P/N 87-120044-001). Carefully install the cartridge into the valve assembly of the XV Control System. Tighten until cartridge is snug (see Figure 4-76). It is permissible to perform this test with the System Cartridge. Do not attempt to push the piercing pin down. Pushing the piercing pin too far can Qcause the 0-ring to move out of the valve bore. This could cause the 0-ring to chip CAUTION or break upon actuation of the system. Inserting the System Nitrogen Cartridge will Push the piercing pin down to the proper location in the valve bore. Note: Do not use a wrench or other tool to tighten the cartridge. Hand tightening is sufficient. If leakage is observed, check the condition of the flat gasket in the valve bore. 0 00 RID n —T—1 TEST CARTRIDGE o ° 1 { KEEPER PIN Figure 4-76. XV Control System, Test Cartridge Placement 2. Locate the cover of the XV Control System. Ensure that the local manual handle is set and that the Safety Pin is inserted (see Figure 4-77). The handle should be locked in the set position. If the handle can turn, adjust until the pin can be inserted all the way through the handle into the body of the cover. Note: Installation of a tamper wire seal can prevent the pin from slipping out. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 31 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 0 LOCAL MANUAL RELEASE HANDLE XV HOUSING \ COVER \.. SAFETY PIN SVA f HIGH PRESSURE NITROGEN TUBING Figure 4-77. XV Control System, Cover Attached 3. Remove the Keeper Pin from the XV Control System Cam/Flag. Carefully install the cover onto the XV Control System enclosure. The cover has a tongue that fits into the groove of the XV Control System enclosure. Center the cover over the XV Control System enclosure and fit the tongue and groove together. While the cover is resting on the XV Control System enclosure, moving it 0 upward could engage the local manual release with the latch, causing the :AUTION XV Control System to release. Keep the cover as centered as possible while performing this step. 4. Fasten the cover to the XV Control System enclosure with the captive screws. Turn the captive screws until snug. Note: The Valve Protection Plates should remain on the top of the Cylinder and Valve Assemblies until directed to remove it. S. Pull the safety pin and turn the handle in the direction of the arrow about 1/8-turn. The system will fire, pressurizing the actuating lines. Note: Do not loosen any of the fittings on the actuating lines at this time. 6. Inspect the actuating lines and SVAs for leakage. Each SVA piston must be in the released position (down) and locked. Check each piston to ensure that it is fully extended and the spring-loaded plunger is extended. Note: If any leakage is observed, appropriate steps must be taken to implement corrective action. However, pressure should be bled off before any action is implemented on the actuating lines. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 32 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL The system uses high pressure. Safety goggles or glasses must be worn. All pressure must be released from the actuation lines before resetting the © Cam/Flag. Failure to do so will cause the head of the piercing pin to protrude WARNING out of the valve bore, exposing the 0-ring. This could result in the 0-ring being damaged, thereby causing malfunction or non-function of the system as designed. Always ensure that the pressure has been released before resetting the Cam/Flag. 7. After ensuring there is no leakage, loosen the swivel fitting located at the bottom right side of the XV Control System (see Figure 4-78). Allow the pressure to vent slowly. When the pressure is completely vented, disconnect the fitting and remove the cover. QTo avoid accidental discharge later in the service sequence, it is important to CAUTION completely disconnect the fitting outside the XV Control System. 1 I Figure 4-78. Fitting on Outside of XV Control System 8. Remove the spent cartridge used for the functional test. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 33 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 9. Discard the spent cartridge in an appropriate manner. Check to ensure the detection lines are set. Refer to Paragraph 4-6.3.1. 10.Reset the Cam/Flag and reinstall the Keeper Pin into the Cam/Flag. Note: Ensure the microswitches are setting properly. Check the Deep Mount Microswitches to ensure the trigger pin is under the paddles of the microswitches and is pushing them up. Check the High Mount Microswitches to ensure the Cam/Flag is pushing down on the paddles. 11.Install the Safety Pin into the local manual release handle of the cover assembly. Install a tamper indicator through the Safety Pin and around the handle. 12.Reset all of the SVAs. Push the spring-loaded plunger in while pushing the piston into the body of each SVA. 13.Carefully remove the Valve Protection Plate from the cylinder valves and install the SVA to each cylinder. Secure with the bolts included. Ensure that each SVA is securely tightened. 0 A System Nitrogen Cartridge is required for final system set up. Using any other CAUTION cartridge could cause malfunction or non-function of the system. Note: Check the condition of the flat gasket in the valve bore. Do not use a wrench or other tool to tighten the cartridge. Hand tightening is sufficient. 71) RAT G"WT llatcoe PN Figure 4-79. Valve Body with Flat Gasket 14.When all SVAs are secured, locate the System Nitrogen Cartridge (P/N 87-120043-001). In the area provided, write the date of installation of the cartridge. Carefully install the System Nitrogen Cartridge into the valve assembly of the XV Control System. Hand-tighten until it is snug. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 34 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL a I - SYSTEM 1.TROGEN CARTROGE o 11 KEEPER PIN I Figure 4-80. XV with System Nitrogen Cartridge Installed 15.Locate the cover of the assembly. Ensure the tamper seal remains intact in the safety pin. 16.Remove the Keeper Pin from the Cam/Flag. 17.Carefully install the cover onto the XV Control System enclosure. The cover has a tongue that fits into the groove of the XV Control System enclosure. Center the cover over the XV Control System enclosure and fit the tongue and groove together. While the cover is resting on the XV Control System enclosure, moving it Qupward could engage the local manual release with the actuation latch, causing CAUTION the XV Control System to release. Keep the cover as centered as possible while performing this step. 18.Fasten the cover to the XV Control System enclosure with the captive screws. Turn the captive screws until snug. Q Securing the High Pressure Nitrogen Tubing onto the XV Control System will complete the setup of the Kidde System. System discharge could occur if the CAUTION system has not been properly set. 19.Secure the High Pressure Nitrogen Tubing back onto the bottom of the XV Control System. Ensure that the fit is properly snug to prevent leakage. Refer to Figure 4-81. 20.Apply labels to the cover of the XV Control System. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 35 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 3-3.3.21 TILT SKILLETS (BRAISING PANS)\ Table 3-24. F Nozzle Coverage Area Items Parameters Maximum Hazard Area 24 in. x 24 in. (610 mm x 610 mm) Nozzle Aim Midpoint of hazard area and placed so it does not interfere with appliance operation Nozzle Location — At the front perimeter line of the 27-112 in. (699 mm) Min. appliance 46 in. (1168 mm) Max. Note: Appliance cover cannot interfere with distribution of agent from the nozzle. X/ I F NOZZLE I / I COVER MUST NOT INTERFERE WITH EDGE OF DISCHARGE PATTERN I / I / I / / / I / / I Ij I I IQ L CENTERLINE OF HAZARD ZONE THE NOZZLE IS TO BE PLACED TOWARD THE FRONT OF THE APPLIANCE TO MINIMIZE THE POTENTIAL FOR THE SKILLET OR BRAISING PAN COVER TO INTERFERE WITH THE NOZZLE DISCHARGE. Figure 3-22. Tilt Skillet (Braising Pan) AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 36 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 3-3.3.1 SINGLE VAT DEEP FAT FRYER WITH DRIP BOARDS Table 3-2. F Nozzle Coverage Area Items Parameters Maximum Hazard Area 18 in. x 18 in. (457 mm x 457 mm) Appliance Area (with drip board) 18 in. x 23 in. (457 mm x 584 mm) Nozzle Aim Midpoint of hazard area at an angle of 45' or more from the horizontal Nozzle Location (from top of appliance) 27 in. (686 mm) Min. 45 in. (1143 mm) Max. AN F NOZZLE MAY BE LOCATED ANYWHERE WITHIN THE GRID DIAGONAL FROM 45 in.(1143 mm)MAX. AIM POINT 45 in.(1143 mm) 45 in.(1143 mm) MAX. MAX. 27 in.(686 mm) MIN. F� MAX. (457 mm) tt Figure 3-2. Single Vat Deep Fat Fryer AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 37 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 3-3.3.2 SPLIT VAT DEEP FAT FRYER Table 3-3. F Nozzle Coverage Area Items Parameters Maximum Hazard Area - Without a Drip Board 14 in. x 15 in. (356 mm x 381 mm) - With a Drip Board 14 in. x 21 in. (356 mm x 533 mm) Nozzle Aim Midpoint of hazard area at an angle of 45° or more from the horizontal Nozzle Location (from top of appliance) 27 in. (686 mm) Min. 45 in. (1143 mm) Max. 45 in (1143 mm)MAX. 45 in.(1143 mm) 45 in.11143 mm) MAX. MAX 27 in.(686 mm) MIN. F� 1� 15 C t2`P+ F� 14 i 1^P� MAX..(356 mm) Figure 3-3. Split Vat Deep Fat Fryer AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 38 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 3-3.3.3 14 in. X 14 in. (356 mm X 356 mm) DEEP FAT FRYER Table 3-4. F Nozzle Coverage Area Items Parameters Maximum Hazard Area 14 in. x 14 in. (356 mm x 356 mm) Maximum Appliance Area 14 in. x 24-1/2 in. (356 mm x 622 mm) Nozzle Aim Midpoint of hazard area at an angle of 450 or more from the horizontal Nozzle Location (from top of appliance) 27-1/2 in. (686 mm) Min. 45 in. (1143 mm) Max. AN F NOZZLE MAY BE LOCATED ANYWHERE WITHIN THE GRID 45 in.(1143 mm) DIAGONAL FROM MAX AIM POINT 45 in. (1143 mm) 45 in. (1143 mm) MAX MAX MIDPOINT OF HAZARD AREA 27-1/2 in. (699 mm)MIN i� 14 in.(356 mm) MAX 24-1/2 in. (622 mm) MAX DRIP BOARD 14 in.(356 mm)MAX Figure 3-4. Nozzle Placement AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 39 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 3-3.3.4 SINGLE VAT DEEP FAT FRYER (WITH DRIPBOARDS LESS THAN 1 IN. [25 MM]) Table 3-5. F Nozzle Coverage Area Items Parameters Maximum Hazard Area 24 in. x 24 in. (610 mm x 610 mm) Appliance Area (with drip board) 24 in. x 25 in. (610 mm x 635 mm) Nozzle Aim Midpoint of hazard area Nozzle Location (at any point on or within the 27-112 in. (699 mm) Min. perimeter of the hazard area) 46 in. (1168 mm) Max. '_ .._.ell, .._- OF ram y! I ------------- 46 (1168 mm)MAX. j r�'r _ -_/ i 27-112 in. I (699 mm)MIN, i i i AIM POINT-MIDPOINT OF HAZARD AREA24 yF Ma In. 1610 mml Figure 3-5. Single Vat Deep Fat Fryer (with Dripboards less than 1 in. (25mm) AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 40 of 41 WET CHEMICAL SYSTEM - INSTALLATION MANUAL 3-3.3.5 SPLIT VAT FRYER (LOW PROXIMITY APPLICATION) Table 3-6. ADP Nozzle Coverage Area Items Parameters Maximum Hazard Area 14 in. x 15 in. (356 mm x 381 mm) Appliance Area (with drip board) 14 in. x 21 in. (356 mm x 533 mm) Nozzle Aim Midpoint of hazard area Nozzle Location (at any point on or within the 16 in. (406 mm) Min. perimeter of the hazard area) 27 in. (686 mm) Max. 27 in. (686 mm)MAX. i I i 16 in. ; -..._. (406 mm)MIN. i I AIM POINT-MIDPOINT OF HAZARD AREA F� 14 in. \5�� (356 MM)MAX. Figure 3-6. Split Vat Fryer (Low Proximity Application) AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME - SPIKKESTAD Page 41 of 41 Fire Suppression System XV Control System 188300 210 0. 95 2 1 J O o o O It N Set 3 O O 0 0 Front view in Set Position 4 with cover 138,60 4xo5mm 0 M The XV Control System is supplied with: Oo Oo 1 Off 188110 Actuator pneumatic 1 Off 188900 Nitrogen cartridge 1 Off 188910 Nitrogen test cartridge 111,50 1 Off 188475 EMT Connector Kit 2 Off 188920 Microswitch Kit Back View 4 1/8"NPT Port for pneumatic actuation Weight: 5,9 Kg 3 PG16 cable gland,port for cable to micro switch 2 1/2"EMT Connector,port for termobulb wire release Actuation: Nitrogen cartridge Finish: Natural 1 1/2"EMT Connector,port for manual wire release Item Description Material: Autronica Fire and Security AS Kidde Wet Chemical System Division Maritime Norway Cast Aluminium Phone: 1295 00,Fx:+ 73129 Phone:+47 31 29 55 00,Fax:+q7 31 29 55 01 XV Control System a-post:info@autronicafire.no O Data Sheet No. • External view Heien 188300-PDS-A-001 Larsen fIUTRONICR- To copy or use this document without owners permission is prohibited �,a. .„o ..... . Fire Suppression Nozzle type 188350 Disc cap '--,�ozzle seal o17 Top view ti U U U Strainer N 3/8" N PT Bottom view Material housing: Brass, nickle plated Material strainer: Stainless steel Weight: 0,06 Kg Flow factor: 2 Material: Autronica Fire and Security AS Kidde Wet Chemical System Division Maritime Industriveien 7,3430 Spikkestad,Norway Brass Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 e-post:info@autronicafire.no O Data Sheet No. Nozzle type "F" Helen 188350-PDS-A Larsen -RUTRONICR- To copy or use this document without owners permission is prohibited Fire Suppression , • • 188900 O co o 40 NOTE: For testing, use test cartridge, part number 188910 Material: Steel Weight: 0,15 Kg Pressure: 186 Bar Material: Autronica Fire and Security AS Kidde Wet Chemical S stem Division Maritime y Industriveien 7,3430 Spikkestad,Norway Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 Data Sheet No. Nitrogen cartridge a-post:info@autronicafire.no a XV Contro system 188900-PDS-A Gff) -RUTRONICFF To copy or use this document without owners permission is prohibited Fire Suppression . • • 188900 V) o 25 NOTE: Replace immediately after successful testing with system cartridge, part number 188900 Material: Steel Weight: 0,07 Kg Pressure: 186 Bar Material: Autronica Fire and Security AS Kidde Wet Chemical System Division Maritime Industriveien 7,3430 Spikkestad,Norway Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 Nitrogen test cartridge a-post:info@autronicafire.no Data Sheet No. XV Contro system Heien O 188910-PDS-A Larssen -RUTRONICR- To copy or use this document without owners permission is prohibited Fire Suppression System Corner pulley 188600 65 o 18 LO L IF A/F 24 Material housing: Cast aluminium Material pulley wheel: Steel ball bearing End connections: 18 mm compression coupling Weight: 0,10 Kg Material: Autronica Fire and Security AS Kidde Wet Chemical System Division Maritime way Cast aluminium Phone: 29553430 0,Fa :+47 129 Phone:+47 31 29 55 00,Fax:+q7 31 29 55 01 e-post:info@autronicafire.no O Data sheet No. Corner pulley Helen 188600-PDS-A Larsen fIUTRONICR- To copy or use this document without owners permission is prohibited R. R NICIT. Fire Suppression • • 188150 G 0 ) CI4 Top view ti N 1/2" NPT F. Section Side view NOTE: To be mounted nearby the cylinder, facing either upwards or against the bulkhead. Material: Brass Weight: 0,050 Kg Material: Autronica Fire and Security AS Kidde Wet Chemical System Division Maritime Industriveien 7,3430 Spikkestad,Norway Brass Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 e-post:info@autronicafire.no O Data sheet No. Vent plug 1/2" NPT Helen 188150-PDS-A Larsen fIUTRONICR- To copy or use this document without owners permission is prohibited R. R NIC.R Fire Suppression pull station188550 6 1/2" EMT Connector C�E OF � Q a y�bH 3l NW rd 77nd gVjI 40 3'cd0 Front view 17 40 Side view O O 0 O O CO r O 10xm5 19 19 50 Weight: 0,40 Kg Back view Material: Autronica Fire and Security AS Kidde Wet Chemical System Division Maritime Industriveien 7,3430 Spikkestad,Norway Aluminium Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 no Data sheet No. Manual release pull station e-post:info@autronicafire. O 188550-PDS-A Gff) fIUTRONICR- To copy or use this document without owners permission is prohibited �,aE .„o sE��a,T. Fire Suppression System EMT Connector 1/2" • • 475 I I I Bottom view Compressing nut TI I , M Compressing ring I I o I 1/2" BSP 24 F /,,* � T Housing C 0O � I O-Ring Top view Nut Weight: 0,07 Kg Material: Autronica Fire and Security AS Kidde Wet Chemical S stem Division Maritime Y Industriveien 7,3430 Spikkestad,Norway Aluminium Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 Data Sheet No. EMT Connector 112" a-post:info@autronicafire.no a 188475-PDS-A Gff) -RUTRONICFF To copy or use this document without owners permission is prohibited Fire Suppression housing kit 188450 203 A io O O Top view Scale 1 : 2 297 0 00 Front view Scale 1 : 2 26 2 6 4 7 7 0 10, �- V 0 - 0 22 S-Hook Wire crimp sleeve Side view Scale 1 : 1 Scale 1 : 1 Scale 1 : 2 1 Set consist of: 1 Off Bracket Finish: Plated 2 Off S-Hook Weight: 0,40 Kg 2 Off Wire crimp sleeve Material: Autronica Fire and Security AS Kidde Wet Chemical System Division Maritime Steel Industriveien 7,3430 Spikkestad,Norway Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 e-post:info@autronicafire.no O Data Sheet No. Link housing kit 188450-PDS-A Gff) -RUTRUNICR- To copy or use this document without owners permission is prohibited �,a. .„o ..... . Fire Suppression System Rapid response link 18850X 41,30 0 Sri N Thermobulb Part number Type DG F DG C Bulb color 188500 KGR-212 212 100 Green 188502 KGR-286 286 141 Blue 188504 KGR-360 360 182 Mauve 188506 KGR-450 450 232 Black 188508 KGR-500 500 260 Black Material: Autronica Fire and Security AS Kidde Wet Chemical System Division Maritime Steel Industriveien 7,3430 Spikkestad,Norway Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 Data Sheet No. Rapid response link e-post:info@autronicafire.no O Thermobulb type 1885OX-PDS-A Gff] fIUTRONICFF To copy or use this document without owners permission is prohibited ., Fire Suppression System WHDR-125 Bracket 188250 /0�1 Top view 164 41 52 F--IIIII IIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIII � N M O O 4 x o 10 M 00 IF � N N T O CO Finish: White Front view Side view Strap: Stainless steel Weight: 0,50 Kg Material: Autronica Fire and Security AS Kidde Wet Chemical System Division Maritime Industriveien 7,3430 Spikkestad,Norway Steel Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 Data sneer No. WHDR-125 Mounting bracket e-post:info@autronicafire.no O 188250-PDS-A Gff) -RUTRONICFF To copy or use this document without owners permission is prohibited Fire Suppression • - _J= �A Pneumatic actuator Included in the XV Control system. Pilot pressure connection Pressure 1/8" NPT gauge IF Cylinder valve outlet co M O co LO co o 194 Front view Side view Cylinder pressure vs Temperature Cylinder: Welded steel 13,78 Finish: White 13,10 Cylinder pressure: 12,05 Bar/21 °C a Propellant gas: Nitrogen m 12,40 Weight: 12,9 Kg y 11,72 Capacity: 4,70 litre a 11,03 Cylinder valve: Brass, plated Operation: Pneumatic 10,34 -18 -12 -7 -1 4 10 15,6 21 27 32 38 43,3 49 Pressure gauge: Steel Temperature°C Material: Autronica Fire and Security AS Kidde Wet Chemical System Inds Maritime Steel ndustririveien 7,3430 Spikkestad,Norway Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 Data Sheet No. Cylinder W H D R-125 a-post:info@autronicafire.no a with pneumatic actuator 188025-PDS-A Gff) -RUTRONICFF To copy or use this document without owners permission is prohibited Fire Suppression System Actuator pneumatic 188110 Pilot pressure connection a z 00 IF - -� - - CO) Bottom view Top view 69,80 51,50 0 0 0 147 Front view Side view 15 a 00 Weight: 0,720 Kg Finish: Crome plated 1/8" NPT Blind plug. Operating pressure: 200 Bar Plug the free port on the actuator Operating medium: Nitrogen on the last cylinder Material: Autronica Fire and Security AS Kidde Wet Chemical System Division Maritime Brass Industriveien 7,3430 Spikkestad,Norway Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 Data Sheet No. pneumatic neumatic for a-post:info@autronicafire.no XV Control system O 188110-PDS-A Gff) -RUTRUNICR- To copy or use this document without owners permission is prohibited �,aE .„o sE��a,T. Fire Suppression System Switch mi • SPDT 188920 Switch arm O e NC e NO C ru") �O O Switch contacts: Brass Contact rating 125/250 VAC : 20,5 Amp Contact rating 24 VDC: 9 Amp Material: Autronica Fire and Security AS Kidde Wet Chemical System Division Maritime Industriveien 7,3430 Spikkestad,Norway Plastic Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 Data Sheet No. Switch micro SPDT a-post:info@autronicafire.no O for XV Control system Heien 188920-PDS-A Larsen -RUTRONICR- To copy or use this document without owners permission is prohibited Fire Suppression System Discharge adapter kit 188100 53,70 CO CO0 CO CO 0 \��A/F24 Discharge adapter 83 3 3,62 AL F' AL 0 rn O 011- V "� M � O-Ring Flange plate Nut 5/16-18 Shipping cap O-Ring Nut 5/16-18 Discharge adapter 0 0 0 Flange plate Material discharge adapter: Brass a late: Steel Bolts 5/16-18 Material flange p 1 inch(25,4 mm)long Finish flange plate: Plated Material O-Ring: Neoprene Cylinder valve assembly Weight: 0,22 Kg Material: Autronica Fire and Security AS Kidde Wet Chemical System Division Maritime Industriveien 7,3430 Spikkestad,Norway Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 e-post:info@autronicafire.no O Data sneer No. Disharge adapter kit ■ Helen 188100-PDS-A Larsen fIUTRONICFF To copy or use this document without owners permission is prohibited R. R NICIT. Fire Suppression A/F 25,4 52 a � N Z Z � N N EO -000 ILL COIF MIF Finish: Chrome plated Weight: 0,10 Kg Material: Autronica Fire and Security AS Kidde Wet Chemical System Division Maritime Industriveien 7,3430 Spikkestad,Norway Brass Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 Data Sheet No. Swivel adapter 3/8" e-post:info@autronicafire.no O for nozzles Heien 188400-PDS-A Larssen -RUTRONICR- To copy or use this document without owners permission is prohibited Fire Suppression System XV Control System 188300 P3 P4 CP) 0 0 0 0 O O O O o 14 O o 12 0 0 ® Ps 13 ❑ 0 0 0 o (o 0 e OReleased A O p O O N O O n O P1 O ep O Pti O op O o 0 0 0 Internal view with cartridge Internal view with cartridge removed, set position removed, released position P1 Cable entry high mounted micro switch P2 Cable entry low mounted micro switch O o 2 P3 Entry for wire from detection line no. 1 P4 Entry for wire from detection line no.2 top port 3 P5 Entry for wire from manual pull to release station 4 P6 Entry for wire from detection line no.2 side port --- 5 ❑ P7 Cable entry for electrical solenoid. 0 P8 Entry mechanical gas valve port. 6 O Released O 14 Pulley wheel for detection line no.2 N 0 13 Lock-out pad for detection line no. 1 QO Qp 8 12 Lock-out pad for detection line no.2 0 0 0 9 11 Port for lock-out pin. 10 11 10 Bracket for deep mount micro switch. 9 1/8"NPT High pressure nitrogen outlet. (DO NOT REMOVE) 8 Internal high pressure nitrogen line.(DO NOT REMOVE) 7 Micro switch high mount 6 Status/setting flag for cam. 5 Spool and ratchet for detection line no. 1 4 Spool and ratchet for detection line no.2 3 Latch and lever for manual pull to trip(wire release) Weight: 5,9 Kg 2 Storage pad for lock-out screws Actuation: Nitrogen cartridge 1 Nitrogen cartridge-186 Bar at 35 dg.0 Finish: Natural Item Description Material: Autronica Fire and Security AS Kidde Wet Chemical System Division Maritime Industriveien 7,3430 Spikkestad,Norway Cast Aluminium Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 XV Control System a-post:info@autronicafire.no O Data Sheet No. • Internal view Heien 188300-PDS-A-002 Larsen fIUTRONICFF To copy or use this document without owners permission is prohibited �. . .„o .E..a,T. Fire Suppression • shield 188200 r 76 I rn 0 0 0 LO C 0 LO Finish: Chrome plated Weight: 0,15 Kg Material: Autronica Fire and Security AS Kidde Wet Chemical System Division Maritime Industriveien 7,3430 Spikkestad,Norway Steel Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 Gauge shield a-post:info@autronicafire.no O Data Sheet No. g • Helen 188200-PDS-A Larsen fIUTRONICR- To copy or use this document without owners permission is prohibited R. R N.1, .R ■ FIRE AND SECURITY Wet Chemical System -fl UTR U N I C R- Important design data FIRE AND SECURITY Standard supply - Wet Chem Part number Description Quantity 116-188025 WHDR-125 1,25 GALLON WET CHEM 1 116-188100 DISCHARGE ADAPTER KIT WET CHEM 1 116-188150 VENT PLUG WET CHEM 1 116-188200 GAUGE SHIELD WET CHEM 1 116-188250 CLAMP CYLINDER WHDR 125 1 116-188300 CONTROL SYSTEM XV WET CHEM 1 116-188350 NOZZLE F WET CHEM 2 116-188400 ADAPTER SWIVEL 3/8" FOR NOZZLE 2 116-188450 LINK HOUSING KIT WET CHEM 1 116-188550 RELEASE WIRE MANUAL REMOTE 1 116-188650 WIRE SS 1/16" (1,6 MM) 50 116-188600 CORNER PULLEY WET CHEM 8 116-188700 WIRE CRIMP SLEEVE 5 116-188475 CONNECTOR EMT / O-RING 3 SET 1 116-188504 LINK KGR-360 182 DGC MAUVE 1 Spare parts - Proposal 116-188350 NOZZLE F WET CHEM 1 116-188504 LINK KGR-360 182 DGC MAUVE 1 116-188750 S HOOK FOR WET CHEM 2 116-188800 NOZZLE SEAL REPLACEMENT 2 116-188850 DISC CAP WET CHEM 2 Additional spares 116-188110 ACTUATOR PNEUMATIC XV WET CHEM 1 116-188900 CARTRIDGE NITROGEN XV CONTROL 1 116-188910 CARTRIDGE TEST N2 XV CONTROL 1 116-188920 SWITCH MICRO KIT SPDT 1 Optional release units 116-188502 LINK KGR-286 141 DGC BLUE 116-188506 LINK KGR-450 232 DGC BLACK 116-188508 LINK KGR-500 260 DGC BLACK 116-188500 LINK KGR-212 100 DGC GREEN AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME, SPIKKESTAD, NORWAY ■ FIRE AND SECURITY Wet Chemical System fIUTRONICR- Important design data FIRE AND SECURITY Installation limitations Stainless Steel Discharge Tubing Max. volume - discharge pipe 1180 cm3 Max. lenght of branch line (When two nozzles) 12,20 m Max. elevation above cylinder outlet 3,70 m Max. elevation branch line above supply line 1,20 m Max. number of F-Nozzles on WHDR-125 2 PCs. Max. equivalent length from cylinder to most remote nozzle 11,90 m Max. equivalent length between most remote nozzle 10,00 m Min. equivalent lenght between cylinder and nozzle 2,60 m Pipe dimension ID cm Volume/meter Max. meter 12 X 1 mm 1,00 78,50 15,04 Pilot tube High pressure stainless steeel pipe 6 x 1 mm Maximum lenght from XV Control system to cylinder 32,00 m Detection line 1 Stainless steel wire 1,60 mm Maximum lenght 61,00 m Maximum number of corner pulleys 50 PCs. Maximum number of temperature bulbs 40 PCs. Detection line 2 Tube dimension OD 18 mm Stainless steel wire 1,60 mm Maximum lenght 61,00 m Maximum number of corner pulleys 50 PCs. Maximum number of temperature bulbs 40 PCs. Manual release line Tube dimension OD 18 mm Stainless steel wire 1,60 mm Maximum lenght 31,00 m Maximum number of corner pulleys 30 PCs. AUTRONICA FIRE AND SECURITY AS DIVISION MARITIME, SPIKKESTAD, NORWAY SuppressionFire D O to r 1 2 E N lD Link housing ki o O Vent plug ire sleeve/7,6 mm Wir _ ermobul Coner pulley � set 'ar e e F-Nozzle v Stainless —�+ steel piping XV Control system Manual wire release Stainless steel high pressure pull type instrument tube,1/4"(6 mm) Material: Autrenica Fire and security AS Kidde Wet Chemical System DmN bn Mantlma Y Ind-tri eien 3430 Spikk-tad,No—y Typical schematic Phone:+47 31 29 55 00,Fax:+47 31 29 55 01 Data sheet No. WHDR-125 cylinder a-post:info@autronicaflre.no O Neien 188025-PID-A with XV Control system Larsen iiUTRONICf To wpy or use this document without owners permission is prehibRetl Date: 03/30/2026 Permit#: 3545 Permit 11/13/2020 Date: Review 11/13/2020 Date: Permit FIRE SPRINKLER Type: Review FIRE SPRINKLER Type: Target Date: 11/20/2020 Scheduled 00:00 Time: Completed 11/16/2020 Date: Description: 1. Permit and set of approved plans to remain on site during installation. 2. Plans indicate the bottom of hood measures approximately 89 inches above floor. The Hoodmart Installation, Operation and Maintenance Manual indicates that typical canopy hood hanging height is 78 inches,but that actual hood hanging height requirements are given on the UL label on the hood. The hood will be required to be installed at the height listed on the UL label AND the suppression system acceptance test successfully witnessed by the City of Arlington prior to final approval given. 3. Final test and inspection witnessed by City of Arlington shall consist of the following: i. Orientation of nozzles shall be verified with the use of a nozzle aiming device. ii.A nozzle cap blow-off test shall be conducted. iii. Signage shall be provided on the exhaust hood or system cabinet, indicating the type and arrangement of cooking appliances protected by the automatic fire-extinguishing system. Signage shall indicate appliances from left to right, be durable, and the size, color, and lettering shall be approved. iv.As there is not a fire alarm system installed in the building, an audible or visual indicator shall be provided to show that the system has operated, that personnel response is needed, and that the system is in need of recharge per NFPA 17A, Section 5.2.1.8.A horn strobe shall be installed to meet this requirement. v. Installation certification form to be completed and submitted. Review Status: Assigned FIRE To: Time In: 00:00 Time Out: 00:00 Hours: 1.5 Review Items O1.Application Requirements Property Information Parcel#: 00461800702000 EOFF FRED R EOFF FRED R 127 E DIVISION ST 127 E DIVISION ST ARLINGTON, WA 98223 Zoning: 581 Eating Places (Restaurants)Lot: Block: THE FOUNTAIN RESTAURANT Permit#: 3545 Permit Date: 11/13/20 Permit Type: FIRE SPRINKLER Project Name: The Fountain Restaurant Applicant Name: Pye Barker Fire Applicant Address: 735 E Fairhaven Ave Applicant, City, State, Zip: Burlington,WA 98223 Contact: Nisha Taylor Phone: 360-755-5444 Email: taylorn@pyebarkerfire.com Scope of Work: Fire Suppression for restaurant Valuation: 1786.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 11/17/2020 Permit Expires: 05/16/2021 Form Permit Type: Status: LASERFICHE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00461800702000 127 E DIVISION ST EOFF FRED R 581 Eating Places (Restaurants) Contractors Contractor Primary Contact Phone Address Contractor Type License License# Pye Barker Fire Nisha Taylor 360-755-5444 PO Box 265 CONSTRUCTION COA 604 541 987 CONTRACTOR CONSTRUCTION Labor and Pye Barker Fire Nisha Taylor 360-755-5444 PO Box 265 CONTRACTOR IndustriesPYEBAFS807DO Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 12/04/2020 Inspection Hood suppression system 12/04/2020 12/04/2020 Mike Makela Approved Final Approved Plan Reviews Date Review Type Description Assigned To Review Status 1.Permit and set of approved plans to remain on site during installation. 2.Plans indicate the bottom of hood measures approximately 89 inches above floor.The Hoodmart Installation,Operation and Maintenance Manual indicates that typical canopy hood hanging height is 78 inches,but that actual hood hanging height requirements are given on the UL label on the hood.The hood will be required to be installed at the height listed on the UL label AND the suppression system acceptance test successfully witnessed by the City of Arlington prior to final approval given. 3.Final test and inspection witnessed by City of Arlington shall consist of the following: i.Orientation of nozzles shall be verified with the use of a nozzle aiming device. 11/13/2020 FIRE SPRINKLER FIRE ii.Anozzle cap blow-off test shall be conducted. iii.Signage shall be provided on the exhaust hood or system cabinet,indicating the type and arrangement of cooking appliances protected by the automatic fire- extinguishing system.Signage shall indicate appliances from left to right,be durable,and the size,color,and lettering shall be approved. iv.As there is not a fire alarm system installed in the building,an audible or visual indicator shall be provided to show that the system has operated,that personnel response is needed,and that the system is in need of recharge per NFPA 17A,Section 5.2.1.8.A horn strobe shall be installed to meet this requirement. v.Installation certification form to be completed and submitted. Fees Fee Description Notes Amount Fire Sprinkler System Commercial NFPA 13/13R $175.00 Processing/Technology $25.00 Fire System Plan Review Table 4-1 $100.00 Total $300.00 Attached Letters Date Letter Description 11/16/2020 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 11/16/2020 Nisha Taylor 83457305 $300.00 Outstanding Balance $0.00 Notes Date Note Created By: 12/02/2020 One inspection already occurred,only one more allowed before additional inspection fee of Kristin Foster $150.00. Uploaded Files Date File Name 09/21/2021 9730063-3545 Inspection-Hood suppression final.pdf 11/17/2020 7713557-3545 Issued Permit.pdf 11/13/2020 7696209-3545 Plans.pdf 11/13/2020 7696190-3545 Application.pdf