17011 59th Ave Ne_BLD2789_2026
CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:17011 59th Avenue NE,Bldg A Permit#:2789 Parcel#:31052700100900 Valuation:10000.00 OWNER APPLICANT CONTRACTOR Name:PREMIER PACIFIC PROPERTIES LLC [Name:Troy Van Kopp Name:The Janes Company,Inc Address: 13600 44TH ST NE Address:13600 44th Street NE Address:8227 44th Ave W,Ste J City,State Zip:LAKE STEVENS,WA 98258 City,State Zip:Lake Stevens,WA 98258 City,State Zip:Mukilteo,WA 98275 Phone: Phone:425-760-8689 Phone:425-267-0202 LIC:JANESC1079D2 EXP: 12/15/2019 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name:The Janes Company Inc Address: Address:8227 44th Ave W.Ste J City,State,Zip: City,State,Zip:Mukilteo,WA Phone: Phone:4252570202 LIC#: EXP: LIC#:JANESC1079D2 EXP: 12/15/2019 JOB DESCRIPTION PERMIT TYPE: Commercial Plumbing CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRCI10. SALES TAX NOTICE:Saks tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Troy Van Kopp 5/4/2020 D Z Signature Print Name Date Released By Date CONDITIONS Adhere to approved plans. Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED,THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/02/2019 Plumbing Permit Base Fee $25.00 10/02/2019 Plumbing Permit Fee(Enter Fixture Fee) $132.00 10/02/2019 Processing/Technology Fee $25.00 10/02/2019 Plumbing Plan Review Fees $250.00 10/02/2019 Boiler/Compressor $25.00 10/02/2019 Water Heater $25.00 Total Due: $482.00 Total Payment: $0.00 Balance Due: $482.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon COMMERCIAL PLUMBING r PERMIT APPLICATION 'A o` Department of Community&Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551 WHEN is a PLUMBING PERMIT REQUIRED? The City of Arlington requires a plumbing permit before a plumbing system or fixture is installed, altered, or remodeled. This also includes replacement of a Hot Water Tank. The City of Arlington does not require a permit to stop leaks or clear stoppages, unless the piping being repaired is altered or replaced. PLUMBING PLAN REVIEW IS REQUIRED FOR THE FOLLOWING PROJECTS 1. New Commercial Buildings 2. New Multi-Family Buildings 3. Roof Drains and Overflow Systems 4. Tenant Improvements 5. Installation of Medical Gas Systems 6. Installation of Commercial Kitchen's and Deli's 7. Installation of Grease Traps 8. Installation of Grease Interceptors 9. Installation of Sumps lo. Installation of Cross Connection Backflow Devices SUBMIT TWO (2) COPIES OF THE FOLLOWING FOR PLUMBING PLAN REVIEW: ❑ Plumbing plans or drawings. (Minimum plan size is 18" X 24" scale, %" scale for details.) ❑ Provide one set of plumbing drawings maximum size 11" X 17" ❑ Size of sanitary and potable water systems. ❑ Location, type and specifications (cut sheets) of proposed fixtures and equipment. ❑ Riser diagram of waste and vent, potable water and rain water systems, including sizes. ❑ Medical gas piping riser diagram indicating type of gas, storage room and size of piping. ❑ Location and type of all backflow assemblies for each fixture. I hereby certify that I have read and examined this application and know the same to be true and correct and I am authorized to apply for this permit. 6/16LP Page 1 of 3 The Janes Company,Inc 425-267-0202 8227 44th Ave W, CONTRACTOR Ste J Plan Reviews Date Review Type Description Assigned To Review Status 09/13/2019 Commercial Plumbing Building In Review 0911 3/20 1 9 Commercial Plumbing PW Admin Rev In Review 09/13/2019 Commercial Plumbing PW-Sew-Rev In Review 09/13/2019 Commercial Plumbing PW-Wat-Rev In Review Uploaded Files Date File Name 09/13/2019 5006132-2789 Iso Plans.pdf 09/13/2019 5606131-2789 A i• f _ RIfllllo_4sL .l1,P� i - I COMMERCIAL PLUMBING ' PERMIT APPLICATION Department of Community&Economic Development City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone (360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS, AND TWO (2) SETS OF FIXTURE SPECIFICATIONS (CUT SHEETS). CALCULATIONS ARE REQUIRED FOR GREASE INTERCEPTOR/F APPLICABLE. Type of Permit: BNew Installation 0 Addition/Alteration Industrial Project Address: /7 01 f S9 7-9 A yE W Parcel ID#: -1)y"Ll- 71'9)j6 C „ Lot#: AL,136 "'A Subdivision: w/.+ Project Description: a-f-1 L- �)C32/ Valuation: Owner. 2CYI)1- Z-4'e- Phone Number: 'VZ5'- 7&0-94-&9' Address: II('PC, tiyt� 57- -14—' City:44/�L SY''X-a State: Zip Code: 98.25e Contact Person: ��� Y y'�4 A-10.0>° Phone Number: Cell Phone: ��S' -7w�'" ���`� E-mail: Address: >3 i-" ''/ / 7W 57- "jam City:Z4 AeF _SZA S State: IV Zip Code:_9 Q 2 S c8' Contractor: /yyscT LJEVT Cc,,yR2OWPO %S ,n-C Phone Number: 34,0-&S3®722y Cell Phone: Email: Address: _38`l) 14-4-7w 004 WE 4 f 2.3 City,-oke--4 7t3N State: A/M Zip Code: Contractor License Number: A1647- PC Expiration Date: Please indicate number of fixtures: n Water Closet Floor Sink �_ Sump Hose Bibb Miscellaneous Lavatory Laundry Tub Washer _ _ Water Heater _ / Grease Trap Urinal Interceptor Sink f Med Gas Drinking Fountain Floor Drain 3 Dishwasher Backflow i Shower Other L P•NO t IzEcT Q wr►,N /P4 Ao m e-t o*GC �Q/y 7*6 1Aare5 C 4mM PA V y' r-dC V2C-2C.`7- 0240A C o6i4l L/2S='7s-y_17oz Z- ,4,t: Bc�G� �A.dGscc.vrP��.y'.GEa.�. g 2 Z 7 e4y7W .411E w I M _T 0 .0"v .eic7'E, iJ A, 9 &::t 7S' Cn•q'To t 0'79Yj:k EYp 4-4 AE /2_ >S'.J9 6/16LP Page 2 of 3 A .. COMMERCIAL PLUMBING PERMIT APPLICATION Lf NG1 Department of Community&Economic Development City of Arlington • 18204 59th Ave NE•Arlington, WA 98223 • Phone (360)403-3551 PROPOSED BUILDING USE New Commercial ❑ Restaurant ❑ Automotive Based ❑ Commercial Addition/Alteration ❑ Office ❑ Machine Shop ❑ Industrial ❑ Medical ❑ Other: CROSS CONNECTION Please check all appliances that are proposed or are permanently connected to the water supply. ❑ Ice Machine ❑ Dialysis Equip. ❑ Air washers ❑ SwimmingPools ❑ Fire Sprinkler • Coffee Steam Sprinkler Hydrotherapy Equip. Hot Tub/Spa ❑ Urn/Espresso Generators w/chemicals ❑ Carbonated Bev. ❑ Dental Equip. ❑ Dye Vats ❑ Aquarium ❑ Lawn Irrigation ❑ Fume Hoods ❑ Laboratory Equip. ❑ Pressure ❑ Decorative ❑ Well on Washers Fountain property ❑ Degreasers ❑ Autoclave/Sterilizers ❑ Cooling Towers ❑ Other: WASTEWATER DISCHARGE 1. Does the plumbing system currently have a grease interceptor? ❑ Yes �__'"� No ❑ Don't Know Date grease trap/interceptor was last cleaned (provide service record): 2. Does the plumbing system currently have an oil/water separator? ❑ Yes ___i No ❑ Don't Know 3. Date oil/water separator was last cleaned (provide service record): 4. Is water used in the business process (washing, rinsing,cooling)? ❑ Yes ❑ Don't Know 5. Does your business require a NPDES permit? _� Yes _c`No ❑ Don't Know I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-described property will be in accordan with the laws, rules and regulation of the State of Washington. ` - C/_ 9 Applicants Signature Date Tp-oy V,4,4 Print Applicants Name FOR STAFF USE ONLY 2,10901 Deceived Permit# Accepted By Amount Received Receipt# Date Receiv 6/16LP Page 3 of 3 r . �.� �•. J Permit#: 2789 Permit Date: 09/13/19 Project Name: Royal Storage Site Address: 17011 59th Avenue NE Applicant Name: Troy Van Kopp Applicant Address: 13600 44th Street NE City, State, Zip: Lake Stevens, WA 98258 Contact: Troy Van Kopp Phone: 425-760-8689 Email: troy@sharpdesignbuild.com Permit Type: Commercial Plumbing Valuation: 0.00 Status: Applied Permit Issued: Permit Expires: Square Feet: 0 Type of Construction/Occupancy Type: Number of Stories: 0 Proposed Use: Plumbing for office of storage unit facility MIC/Opportunity Zone: MIC Status: IN PROCESS Property Parcel# Address Legal Description Owner Name Owner Phone Zoning Section 27 Township 31 Range 05 Quarter NEIA- PAR 2 OF BLA REC AFN 200108315002 EXC TH PTN OF SD PAR 2 LY N 31052700100800 17011 59th Avenue NE OF S LN OF PAR 1 OF SD PREMIER PACIFIC 910 Undeveloped BLA PROJ ELY TO E LN PROPERTIES LLC (Vacant)Land OF SD PAR 2&EXC RDS -AKA PAR 2 OF CITYOF ARL BLA NO Z-06-015- BLA REC AFN 200606055267 Contractors Contractor Primary Contact Phone Address Contractor Type License License I FIRE TUBE BOILER Z D O I _ O O © I I I I ©i a +' z uf` oil © - jo ISM- �[,u�himar KNIGHT FEATUR S 1 I + I UNIVERSAL VENT CONNECTOR © I I Allows for easy mStalhoon of mulupl Vent mate irtl.. II FIRE-TUBE HEAT EXCHANGER Low Pressure drop saves on pump opt ration costs and provides installation flexibility,while-t.mnless steel hghts off currosion SMART SYSTEM USER INTERFACE A plain F.ngfiSh,code fr oe interface wi h multicolor diagnuslic display I f�, I 10:1 MODULATION TURNDOWN z Save—,money on fuel coat. O 0 O � � p _ ELECTRICAL OUTLET(not shown on WHB) APP • OV_� Plug avmlahle.for work light or condcr�sate pump 0 z Y m � � LOCH-N-LINK`" USB PROGRAMMING Y • i Allows for saving of parameter s onto is 1,613 di iv(,for utie at R a differ ent job site. INSTALLATION FLEXIBILITY -fop and hottom water conneclron for they WHB,lop and 101 side utihty connectrons for the I<HB for easy retro fitting, Lochinvar.com SUCK as a cast iron efficiency upgrade., -. �„: . . ._ . � � � Y l• 1 '�� 1 i . . � ,� �� �_ BOILER CONTROL FROM ANYWHERE The industry's most advanced boiler control system now Includes the CON*US'Remote Connect option and Loch-N-Link® USB drive programming feature. See next page for a complete list of SMART SYSTEM'functions and features. From wherever you are,the CON*US option lets you use any intern et-capable device to link up with the SMART SYSTEM on an unlimited number of KNIGHT boilers.With CON*US,you're always In touch and In control.Optional CON*US control board is sold separately. DO REGULAR CON•X•US CHECKS FOR ALL YOUR KNIGHT CUSTOMERS, AND CONiX US' LET THEM KNOW YOU'RE MONITORING THEIR BOILER'S PERFORMANCE. » ADJUST SETPOINTS, DOMESTIC HOT WATER, RESET CURVES, PUMP DELAYS AND MORE, USING THE CON*US INTERACTIVE DISPLAY. » STATUS ALERTS VIA TEXT OR E-MAIL LET YOU KNOW WHEN A KNIGHT BOILER NEEDS ATTENTION. U THE ULTIMATE IN BOILER CONTROL LY _E WTM AND MONITORING The backlit,user-friendly LCD display provides diagnostic information and system status in real words,not codes including: SET-UP WIZARD SETUP WIZARD For fast and easy programing. BOILER PUMP TYPE: VARIABLE RAMP DELAY Six steps of modulation to extend runtime and reduce cycling. 5 T Nor LOCH-N-LINK Save parameters on a USB drive and take them with you for future use. VACATION MODE Tell your boiler when you are out of town to save energy. OUTDOOR RESET WITH BOOST Automatically change the set-point according to weather conditions. MODULATION FACTOR Fine tune boiler performance to be more or less aggressive depending on the application. VARIABLE SPEED BOILER PUMP CONTROL Keep the same Delta T at all firing rates to save electricity and increase performance. _ ■ 1 ti • a I ti .ti . =J1 PI ' F . ■ f •'+� _ i P r ■ ' rrPr _ 1 ■ K: 1 I THE BEST JUST GOT BETTER New features include: SET-UP WIZARD VARIABLE SPEED ECM PUMP UNIVERSAL VENT CONNECTOR WITH ANALYZER PORT 110V CONVENIENCE OUTLET PARTS COMPATIBILITY BETWEEN FLOOR AND WALL MODELS AUTOMATIC PARAMETER RESTORATION WHEN CONTROL IS REPLACED WHB KNIGHT WALL MOUNT TM SMART SYSTEM UNCTIONS AND FEATURES SMART SYSTEM'" FEATURES ))Smart System Digital Operating Control ))low-Voltage Terminal Strip *Vertical&Horizontal Direct Vent Multi-Color Graphic LCD Display w/Navigatlon Dial, Domestic Hot Water Recirculation Pump Start/Stop PVC,CPVC,Polypropylene or SS Venting up to 100 feet Soft Keys and Loch-N-Link*USB programming 24 VAC Device Relay *Universal Vent Adapter ')Three Boiler Setpoint Temperature Inputs Configurable Proving Contacts Built-in Combustion Analyzer Port Plus Domestic Hot Water Prioritization Flow Switch Contacts ))Smart System Control ))Built-in Cascading Sequencer for up to 8 Boilers, Alarm on Any Failure Contacts n Condensate Trap with Cascade Redundancy Runtime Contacts a ECM Variable Speed Boller Circulating Pump Multiple Size Boiler Cascade DHW Thermostat Contacts *110V Convenience Outlet Lead Lag 3 Space Heat Thermostat Contacts *High Altitude Models Available Efficiency Optimization System Sensor Contacts u Other Features Front End Loading Capability Domestic Hot Water Tank Sensor Contacts Automatic Reset High Limit ')Outdoor Reset Control with Outdoor Alr Sensor Outdoor Air Sensor Contacts Adjustable High Limit w/Manual Reset Programmable for Three Reset Temperature Inputs Cascade Contacts Boiler Circulating Pump n Programmable System Efficiency Optimizers 0-10 VDC BMS External Control Contact Zero Clearances to Combustible Materials Space Heat Night Setback 0-10 VDC Boiler Rate Output Contacts 15-Year Limited Warranty(See Warranty for Details) Domestic Hot Water Night Setback 0-10 VDC Variable Speed System Pump Signal Input 5-Year Limited Parts Warranty Anti-Cycling 0-10 VDC Signal to Control Variable Speed Boiler Pump n Firing Codes Outdoor Air Reset Curve Modbus Contacts M9 Standard Construction Ramp Delay nTlme Clock M7 California Code Modulation Factor Control ))Data Logging OPTIONAL EQUIPMENT Boost Temperature&Time Hours Running,Space Heating ')Four Pump Control Hours Running,Domestic Hot Water CON•X•US'Remote Connectivity System Pump with Parameter for Continuous Operation Ignition Attempts Modbus Communication Boiler Pump with Variable Speed Control Last 10 Lockouts BACnet MSTP Domestic Hot Water Pump *Maintenance Reminder Flow Switch Domestic Hot Water Recirculation Custom Maintenance Reminder with Low-Water Cutoff w/Manual Reset&Test ))Domestic Hot Water Prioritization Contractor Contact Information Alarm Bell DHW tank piped with priority in the boiler loop Installer Ability to De-activate Service Reminder Concentric Vent Kit DHW tank piped as a zone in the system with the pumps ')Low-Water Flow Safety Control&Indication SMART SYSTEM"PC Software controlled by the SMART SYSTEM a Password Security Condensate Neutralization Kit DHW Modulation Limiting ')Customizable Freeze Protection Parameters BMS Gateway to LON or BACnet IP Separately Adjustable Space Heat/DHW Switching Times STANDARD FEATURES Multi-Temperature Loop Control *Building Management System Integration Sidewall Vent Termination 0-10 VDC Input to Control Modulation or Setpoint ')ENERGY STAR Most Efficient Product *95%DOE AFUE Efficiency(WHB 55.285) Wireless Outdoor Sensor 0-10 VDC Modulation Rate Output *Modulating Burner with up to 10:1 Turndown LP Conversion Kit 0-10 VDC Input to Enable/Disable Call for Heat))Access to BMS Settings through Graphic LCD Display Direct Spark Ignition ')High-Voltage Terminal Strip Low NOx Operation n 120 VAC/60 Hertz/1 Phase Power Supply ASME Stainless Steel Heat Exchanger 30 PSI ASME Relief Valve Three Sets of Pump Contacts n MNPT Top and Bottom Water Connections (WHB 5S-285 only) KNIGHT BOILER DIMENSIONS AND : CIFICATIONS FRONT _ G LEFT SIDE �--AU hnake L Water Outlet - � A(Outlet Flue Vent TOP D I.- Gas wet C - - A c Wafer- 4� /8" E 1 � wet 8 , B 19" \,-- Hit Voltage RectriA Hit F Low Voltage o e $ I K ElecMcd Carme<tan L ,, ham- 16" �- (andeesate Dr& FLOOR MOUNTModel Capacity Net Gas Water Air Vent Shippin 1 Input MBH Heating Nurriber KNBOSSN SS 8.3 95.0 51 44 3.1/2' 1344' 6' 2.3/4' 37.2/3' 13.1/2' 8.1/3' 10-I/2' IS' 32-1/2' 8.1/3' 1/2' 1- 2' 2' I60 K41108511 85 8.5 95-0 79 69 3.1/2' 13.1/4' 6' 2.3/4' 37.2/3' 13.1/2' 8.1/3' 10.1/2' IF 32.112' 8.1/3' 1/2' 1' 2' 2' 165 KN811ON 110 II 9S.0 102 89 2.3/4' 14.3/4' 7.1/2' 2.3/4' 38' 14.1/3' 9.3/4' 10-Iff 15' 33' 8.1/3` 1/2' 1' 3' Y 170 KHB155N ISS 11.1 95.0 144 12S 2.3/4' 14•3/4' 1.1/2` 2.1/2' 38' 14.1/3' 9-3/A'._ 10.1/2' 1S' 33' 8.113' 1/2' 1' 3' 3' 175 KN817.9N 199.9 19.9 95.0 185 161 3' 1S•1/2' 7•I/2' 2.1/2' 38-1/3' 14.1/3' 10-1/2' 11.1/2' IS' 33' 8.1/3' 1/2' 14/4 3' 3' 195 KH.MIN 285 285 950 264 229 3' I5.1/2' 7.1/2' 2_112' 39•I/3' 141/3` 10.1/Y 11.1/2- IS- 33' 8.1/3' 1/2- 1.1/4- 3- 3' 20S RIGHT SIDE TOP HigghVoltoge BOTTOM H yl Flee Vint 9emk Connection - - law Voltage F AIr intake Nectriml Connection Water Wet AC Outlet \ 0000 6 00 E O J { - Condensate Drala G - K b • ` 1."N Gas wet - - B �{ M I 4 Water Outlet WALL MOUNT C `+ Input Model Capacity Net Gas Water Air Vent Shipping E F G H I I K L M N Conn. Conn. inlet Size Wt (tbs. WHOOSSN 55-_8.t__95,.0- 51 44 40' 18-3M` 16' 31•I/8' 8.1/2' 374- 4.1/Y d•1/2' 1.1/4' 8.1/8' 3.1/Y 1-1/2' 1.1/Y 6' 1/2' 1' 2' 2' 139 W811085111 85 8.5 9S.0 79 69 39.3/4' 18.3/4' 16' 31-1/8' 8-1/2' 3.3/4' 4.1/2' 6.1/2' 7.1/4' 9-7/8' 3.1/2' 1.1/2' 1-1/2' 6' 1/2' 1' 2' 2' 142 WH8110N 110 11 95,0 102 89 41-1/4' 18-3/4' 19' 31.1/8' 10' 2-3/4" S' 5-11A' II-1/r 8.1/2' S' I' 1' 4-1/2 1/2' I' 3' 3' IS9 -WHBI55K IS5 IM 95.0 144 125 41-1A' 18.3 4' 19.1/8' 31.1/8* 10' 2.3/4' 5' S-IA' 11.1/2` 8-1/2' S' 1' 1' 4.1/2, 1/1' 1' 3' 3" 166 WHBI998 199.9 19.9 95.0 185 161 41-1A' 18.3/4' 19.1/8' 31-1/8' 10.112*3' S-1/4' 6' 11' 9.1/2- 6-IA- 1.1/2' 1.1/2' 4.1/2` 1/2- 1.1t4- 3' 3' n WHB28SN 28S 28.5 95.0 264 229 41.3A' 18.3A' 21.1/8' 31-1/8' 15' 3' 3.3/4' 5.1A' 12•IA' 11' 6.1/4' 1 1/2' 11-1/2" 6 1/2' 1/2' 1 1/4' 3' 3' 184 W0839911-399 80 94.9^3771 328 43.1/4' 2S-1/4' 21.7/8' 34' 3.1/2' 4-1/4' 22.1/2'3.7/8' 8-7/8' 12.1/2' 9.114" 2' 2' 21 1/2'3/4' 1-1/2' 4' 4' 213 Information subject to change without notice.Change"N"to"L"for LP gas models.The Net AHRI Water Ratings shown are based on a 'Thermal Efficiency% piping and pickup allowance of 1.15.Lochinvar should be consulted before selecting a boiler for installations having unusual piping and #Gross Output MBH pickup requirements,such as intermittent system operation,extensive piping systems,etc.The ratings have been determined under the provisions governing forced draft burners. "10:1 Turndown ratio and top and bottom water connections are not included on WHB399.WHB399 operates with a 5:1 turndown. vis�o� ' 0�f 4 INK a 1 ■ 1 1 ■� ■ I -1 ■ I '1 1 J L 1 I - ar. 1 ' 1 ■ ■ a r . i 1 ■ ME ■ j l i NO —k a.. EM.M .Mb ■ ■ 1 r L ■ C or ME ■ OME 1 1 / IND US TRIES LTD. pop MODEL MF300 `PRESSURE PAL'MINI SYSTEM FEEDER , V O The `PRESSURE PAL' is ideal for feeding and pressurizing q4NIVOOF closed hydronic systems that do not require cold static fill pressures higher than 170 kPa (25 psig). It is compatible with both water and glycol/water solutions. Perfect for small boiler/chiller systems, snow/ice melt circuits, outside air heating/cooling glycol coils, solar heating systems. FEATURES and BENEFITS ■ 651itre (17 US gallon) tankfor storage and mixing ■ Power supply plugs into any standard 115 VAC outlet ■ Diaphragm pump can run dry without damage ■ No direct connection to potable water supply eliminates need for backflow prevention ■ Make-up fluid stored in the feeder tank can be pre-treated ■ Diverter valve allows easy purging of air on initial start-up, and manual agitation of solution ■ Prevents major floods-in the event of system rupture, only the contents of the tank will be pumped into the system ■ Provides leak detection-dropping fluid level provides immediate notice that the system has developed a leak ■ Fluid drained for service can easily be put back into the system ■ Fluid level switch shuts the pump off if the storage tank level gets too low ■ Auxiliary dry contact included for remote low pressure alarm (alarm optional or by others) Represented By: AXIOM INDUSTRIES LIMITED 2615 WENTZ AVENUE SASKATOON,SK S7K 5J1 TOLL FREE:(877)651-1815 PHONE:(306)651-1815 FAX:(306)242-3373 1 1 �� ti y �. � ' 1INI U ST I TRIES LIARTED MF300 HYDRONIC SYSTEM FEEDER TECHNICAL INFORMATION WEIGHT- 6.8 kg,15 lbs. - le Mini-Feed ELECTRICAL ` Fused Power supply adapter - •-- 115/60/1 to 24 VDC 3B fn Rated 50 watts AC 900 mm LED Power Light 32 in 800 mm PUMP PERFORMANCE 0.04 1/s(0.7 gpm)@ free flow Self-priming up to 1.2 m(4 feet) L_ 11•75In I 300 mm J� SPECIFICATION Depth in 300 mm Clearancesnces-Sides and Top-121n 305 mm Discharge 1/Y'FPT Hydronic system feeder shall be AXIOM INDUSTRIES LTD. Model MF300. System shall include 65 litre (17 U.S. gallon)storage/mixing tank with molded-in level gauge, 125 mm (5")fill/access opening and cover; pump suction hose with inlet strainer and check valve; pressure pump with fuse protection; low fluid level pump cut-out float switch; manual diverter valve for purging air and agitating contents of storage tank; pressure switch with snubber and two sets of SPST dry contacts, each individually adjustable from 70 kPa(10 psig)to 170 kPa (25 psig)cut-out pressure; factory cut-out pressure set to 104 kPa(15psig); and liquid filled pressure gauge. Unit to be c/w fused power supply adapter with LED power indicator light, 115/60/1 to 24 VDC 50 watts AC, supplied loose for field installation. Feeder shall be compatible with glycol solutions of up to 50%concentration. Pump shall be capable of running dry without damage. The second set of contacts in the pressure switch shall be wired to a terminal strip for use as low pressure alarm contacts for remote alarm circuit supplied by others.Unit shall be completely assembled. ACCESSORIES ❑ RIA10-1-SAA—Low Pressure Alarm Panel c/w Remote Monitoring Dry Contacts and Selectable Audible Alarm LIMITED WARRANTY The MF300 is warranted against defects in materials and workmanship for one year. Project _ Location _ Consultant Contractor - Unit Tag _ ,� Sales Agent .. ii i � i r r _ i �� ' - Northwest Plumbing Contractors,Inc. 8/21/19 3810 166`h PL NE#123 Arlington, WA 98223 For: SHARP DESIGN&BUILD LLC 360-653-7224/509-665-3631 NORTHPCO55KB We propose to furnish all materials and labor including the following fixtures and valves necessary to complete the plumbing for: Bid #: 591-06 Name/Address: ROYAL STORAGE SMOKEY POINT NO FIXTURE DESCRIPTION VALVE/FAUCET I FIXTURE COLOR 1 TOILETS: KOHLER K-96057-0/SLOAN 3250400 FLUSH. TOILET W/OPEN FRONT SEAT WHITE 1 ** GERBER MAXWELL EB W/WOOD SEAT WHITE 1 LAVS: KOHLER K-2005-0 WALL MT MOEN L4621 CHROME WHITE 1 ** KOHLER K-2005-0 WALL MT SLOAN 3335061 CHROME WHITE TUBS: SHOWERS: 1 KIT.SINK: ELKAY DSE3322 DELTA 300 CHROME SRS 1 MOP SINK: MUSTEE 63M MUSTEE 63.600A CHROME WHITE DISPOSAL: DISHWASHER: install owners with hot water supply and drain ICE MAKER BOX WITH VALVE: with hammer arrestor BAR SINKS: CLOTHES WASHER HOOK-UP: LAUNDRY TRAY: I WATER HEATERS: RHEEM PROE6-I-RH-POU ELECTRIC I PRESSURE REDUCER I KEYSTOP FROST FREE HOSEBIB 2 FLOOR DRAINS: IN MAIN OFFICE BATHROOM/MOP SINK AREA 2 FLOOR DRAINS: FOR BOILERS IN STORAGE AREA(CONNECTED TO STORM BY OTHERS) REMARKS: Does not include sales tax. Does not include any permits. Drains and vents to be ABS. Water service in ditch by others. All trenching and back-fill by others. All pipe insulation by others. *NOT INCLUDED: +$100 PER FIXTURE FURNISHED BY OTHERS FOR INSTALL COST* ACCEPT PROPOSAL (initials) for the sum of: Conditions of sale: All past due accounts subject to 1.5% monthly service charge. Buyer agrees to pay all costs of collection of past due amounts. L 1 I ' N I ■ 1 f 1 ■ ' 1 ti • ■ 1 ■ r 1 I 1 � • 1 C r .rM :. L ■ ME • • tl■ l I 7 ' 1 ■■ ■ ■ MINE lm - ■ r IN ■ 1 . 1 �. ' ■ ■• • 1. 1 ■ • . . 1 • y ■ ■ 0 ■ 1 ■ 1 1 0. • . ■ ■ mi 11 ■1 ■■ ■■ ■ ■ ■ . ■ ■ ■ ■ ■ ■ ■ ■ 1 ■ K t '4 � r .� , �, � , � _ t ,Qt `: ! 1+ Y � y i' �" i,� `� 11 ,' Y f�� ' ,� � n,�� � ;F �'� � � �� P r= a � �+ a �� s� � � .�, r `_ ,., ,��r. r ,� � �_ ��,��}, �.t�', f. ' y�; ��� � �NF' 1 I 1R � � �,, #� '�' � I` ��y '� a��. f � � a '�`t '- i �`�'1 i s , '� � ��< � .� � , r �,` 5�. 5` � � s J > �. Ir '� �u7�� S , � �' � /� '�i�� i � �' '��.� —-�, � ', � � � ,�, �; .� �' �� �. •�."� �� �• ra ;� � . � , , '� t X. � - •y•<. .�"�v;�, 4�' .�,. .. INSPECTION REQUEST PROCEDURE To schedule an inspection: Call the Automated Inspection Line (360) 403-3417 Required Information: -Permit Number (Building, Right of Way or Civil) -Inspection Request (Type) -Inspection Time (am or pm) • A.M. inspections are scheduled from 8:00 am to 12:00 pm • P.M. inspections are scheduled from 1:00 am to 4:00 pm • You may request a specific time. We will do our best to honor the time requested. The Automated Inspection Line responds exactly like voicemail. Simply listen to the voice message and leave the information indicated above. You may stay on the line and request multiple inspections giving the required information each time. • Inspections must be called in before 3:30 PM to be on the next day inspection schedule • Fire Suppression (fire alarm,fire sprinkler) inspection requests require at least 48 hours advanced notice • To cancel or modify an inspection please call (360) 403-3433. a � �, �� ��,� �� - 0 FIRE TUBE TUBE BOILER 1 z O �I - a I � I ' Y I r p �s�. p' KNIGHT FEATURES •� I UNIVERSAL VENT CONNECTOR Allows for easy installation of mulnpl vent materials, 2 FIRE-TUBE HEAT EXCHANGER Low I Q'Mjrt;drop saves on Pump Operation costs and provides installation flf:xibility,while Mainless Sleel fights Off corrosion. i 3 SMART SYSTEM USER INTERFA E A plain EnE,lish,code flee interface wi h multicolor diagnostic display. ' ~ � 10:1 MODULATION TURNDOWN z Saves money on luel cost, D © • OO S ELECTRICAL OUTLET(not shown on WHB) BUILDING J APPROVED • * Plug available for work light or condooi ate purnp. _ U l m G LOCH-N-LINK"' USB PROGRAMMING Y ♦ Allows for saving of parameters onto a U513 drive for usf.:it • a dilferentjob iite. . ! C . INSTALLATION FLEXIBILITY Top and holtom water connection for the WHB.Top and left side utility connection~for the KHL'for easy retro fiLLinh, LOChlflval com such aS a cast iron efficiency upgrade. f ;} BOILER CONTROL FROM ANYWHERE The Industry's most advanced boiler control system now includes the CON•X•US'Remote Connect option and Loch-N-Link® USB drive programming feature. See next page for a complete list of I SMART SYSTEM'"functions and features. From wherever you are,the CON*US option lets you use any internet-capable device to link up with the SMART SYSTEM on an unlimited number of KNIGHT boilers.With CON*US,you're always in touch and in control.Optional CON*US control board is sold separately. �.1 » DO REGULAR CON*US CHECKS FOR ALL YOUR KNIGHT CUSTOMERS, AND COAL X US® LET THEM KNOW YOU'RE MONITORING THEIR BOILER'S PERFORMANCE. » ADJUST SETPOINTS, DOMESTIC HOT WATER, RESET CURVES, PUMP DELAYS AND MORE, USING THE CON•X-US INTERACTIVE DISPLAY. ` = » STATUS ALERTS VIA TEXT OR E-MAIL LET YOU KNOW WHEN A KNIGHT unw BOILER NEEDS ATTENTION. i AppStorEj THE ULTIMATE IN BOILER CONTROL • SYSTEM" AND MONITORING The backlit,user-friendly LCD display provides diagnostic Information and system status in real words,not codes including: SET-UP WIZARD For fast and easy programing. 171 RAMP DELAY Six steps of modulation to extend runtime and reduce cycling. LOCH-N-LINK Save parameters on a USB drive and take them with you for future use. Nr VACATION MODE Tell your boiler when you are out of town to save energy. OUTDOOR RESET WITH BOOST Automatically change the set-point according to weather conditions. MODULATION FACTOR Fine tune boiler performance to be more or less aggressive depending on the application. VARIABLE SPEED BOILER PUMP CONTROL Keep the same Delta T at all firing rates to save electricity and increase performance. 1 J 'L � I � 1 . 1� ' 1111 - • Ij '1 � T • � ' I. ti i 1 ^M� 1 ti •. 1 . ti Z■ 1 - Seim t"Gu n TV - - - . . . 'I 1 1 J jr 1 = T %1 . . J THE BEST JUST GOT BETTER New features include: SET-UP WIZARD VARIABLE SPEED ECM PUMP UNIVERSAL VENT CONNECTOR WITH ANALYZER PORT 110V CONVENIENCE OUTLET PARTS COMPATIBILITY BETWEEN FLOOR AND WALL MODELS AUTOMATIC PARAMETER RESTORATION WHEN CONTROL IS REPLACED WHB KNIGHT WALL MOUNT TM SMART SYSTEM FUNCTIONS AND FEATURES SMART SYSTEM-FEATURES DSmart System Digital Operating Control D Low-Voltage Terminal Strip ))Vertical&Horizontal Direct Vent Multi-Color Graphic LCD Display w/Navigation Dial, Domestic Hot Water Recirculation Pump Start/Stop PVC,CPVC,Polypropylene or SS Venting up to 100 feet Soft Keys and Loch-N-Link®USB programming 24 VAC Device Relay D Universal Vent Adapter ))Three Boller Setpolnt Temperature Inputs Configurable Proving Contacts Built-in Combustion Analyzer Port Plus Domestic Hot Water Prioritization Flow Switch Contacts ))Smart System Control D Built-in Cascading Sequencer for up to 8 Boilers, Alarm on Any Failure Contacts D Condensate Trap with Cascade Redundancy Runtime Contacts D ECM Variable Speed Boiler Circulating Pump Multiple Size Boiler Cascade DHW Thermostat Contacts D 110V Convenience Outlet Lead Lag 3 Space Heat Thermostat Contacts ))High Altitude Models Available Efficiency Optimization System Sensor Contacts D Other Features Front End Loading Capability Domestic Hot Water Tank Sensor Contacts Automatic Reset High Limit ,)Outdoor Reset Control with Outdoor Air Sensor Outdoor Air Sensor Contacts Adjustable High Limit w/Manual Reset Programmable for Three Reset Temperature Inputs Cascade Contacts Boiler Circulating Pump D Programmable System Efficiency Optimizers 0-10 VDC BMS External Control Contact Zero Clearances to Combustible Materials Space Heat Night Setback 0-10 VDC Boiler Rate Output Contacts 15-Year Limited Warranty(See Warranty for Details) Domestic Hot Water Night Setback 0-10 VDC Variable Speed System Pump Signal Input 5-Year Limited Parts Warranty Anti-Cycling 0-10 VDC Signal to Control Variable Speed Boiler Pump ))Firing Codes Outdoor Air Reset Curve Modbus Contacts M9 Standard Construction Ramp Delay ))Time Clock M7 California Code Modulation Factor Control ))Data Logging OPTIONAL EQUIPMENT Boost Temperature&Time Hours Running,Space Heating ,)Four Pump Control Hours Running,Domestic Hot Water CON•X•US'Remote Connectivity System Pump with Parameter for Continuous Operation Ignition Attempts Modbus Communication Boiler Pump with Variable Speed Control Last 10 Lockouts BACnet MSTP Domestic Hot Water Pump DMalntenance Reminder Flow Switch Domestic Hot Water Recirculation Custom Maintenance Reminder with Low-Water Cutoff w/Manual Reset&Test ))Domestic Hot Water Prioritization Contractor Contact Information Alarm Bell DHW tank piped with priority in the boiler loop Installer Ability to De-activate Service Reminder Concentric Vent Kit DHW tank piped as a zone in the system with the pumps *Law-Water Flow Safety Control&Indication SMART SYSTEM"PC Software controlled by the SMART SYSTEM aPassword Security Condensate Neutralization Klt DHW Modulation Llmiting DCustomizable Freeze Protection Parameters BMS Gateway to LON or BACnet IP Separately Adjustable Space Heat/DHW Switching Times STANDARD FEATURES Multi-Temperature Loop Control ))Building Management System Integration ))ENERGY STAR Most Efficient Product Sidewall Vent Termination 0- VDC Input to Control Modulation or Setpoint D9S%DOE AFUE Efficiency(WHB SS-28S) Wireless Outdoor Sensor 0-10 10 VDC Modulation Rate Output *Modulating Burner with up to 10:1 Turndown LP Conversion Kit 0-10 VDC Input to Enable/Disable Call for Heat))Access to BMS Settings through Graphic LCD Display Direct Spark Ignition DHlgh-Voltage Terminal Strip Low NOx Operation 120 VAC/60 Hertz/1 Phase Power Supply ASME Stainless Steel Heat Exchanger 30 P51 ASME Relief Valve Three Sets of Pump Contacts D MNPT Tap and Bottom Water Connections (WHB S5-285 only) KNIGHT BOILER DIMENSIONS AND SPECIFICATIONS FRONT r- G - 1 LEFT SIDE Air Make Water Outlet ' ACOude1 .Q { Fb eVent TOP - D I.- - Gas Net A r 43.3/8" °o Wale 0 C fi Net J 8 19, C ---- HighVollage Electrical Hit F I _ - low Voltage K Electrical Connedion ° e $ I 16' L- H - ►i I - Catdeasate Drain FLOOR MOUNT Input Model Capacity Net Gas Water Air Vent Shipping Number Max Min AFUE% MBH MBH A B C D E F G H I I K Conn. Conn. Inlet Size Wt ((bs.) K11805SN 55 8.3 95.0 51 44 3.1/2' 13-/4' 6' 1.3/4- 31-2/3' 13.1/2' 8.1/3' 10.1/2' IS' 32.1/2' 8.1/3- 1/2' 1' 2' E 160 KH8085N 85 8.S 95.0 j.9 69 3.1/2' 13.1/4' 6' 2-3/4' 37.213" 13.1/2' 8.1/3' 10-1/2' IS' 32.1/2' 8-1/3' 1/2" 1' 2' 2' 165 KH811ON 110 11 95.0 102 89 2.3/4' 14.3/4' 7.1/2' 2.3/4' 38' 14.1/3' 9.3/4' 10.1/2' 15' 33' 8.1/3' 1/2' I' 3' 3' 110 KN8155N 1SS 15.5 95.0 144 13,5 1.3/4- 14.3/4- 71/2- 2.1/2' 38- 14.1/3- 9.3/4- 10.1/2' IJ' 33- 8-1/3' 1/2' 1' 3' 3' US KNO199H 199.9 19.9 95.0 18S 161 3' 15.1/2' 7.1/1' 2-1/2' 36-1/3' 14.1/3- 10.1/2' 11.1/2' IS- 33- 8-1/3' 1/2' 1.1/1 3' 3' U5 K18285N 185 28.5 95.0 264 229 3' li IJ2_ 1.(/-2' .36.1/3" 14.1/3" 10.1/2' 11.1/2' IS- 33- 8.1/3' l/2' RIGHT SIDE T TOP High Voltoga BOTTOM Flee Vent Electricd Cormedion - low Voltage F H Air Make Electrical Connection Water Net AC Odell s_ Q 000 6 0O E 6 . � - OR A Ili D I ! ! Condeasate Drdn G • E i Gas Net 9 = M H-4 - Water allot + -� WALL MOUNT C Input lviuutt k-dpacity Net Gas Water Air Vent Shipping E F G H I K L M N Conn. Conn. Inlet Size Wt.(Ibs.) 111111180550 SS 8.3 95.0 51 44 40' 18.3/4' 16' 31-1/8' 8.1/2' 3.3/4' 4.1/2' 6.1/2' 1.1/4' 8.7/8' 3.1/2' 1.1/2' 1.112' 6 1/2' 1' 2- 2- 139 W11 08SN 8S 8.5 91.0 79 69 39.3/4' 18.3/4' 16- 31.1/8' 8.1/2' 3-3/4' 4.1/2' 6.1/2' 7.1/4' 8.7/8' 3.1/1' 1.1/2' 1.1/2' 6' 1/2' 1' 2' 1' 42 WWHBIION 110_ 11 95.0 102 89 41.114' 18-3/4' 19' 31.1/8' 10' 2.3/4' S' 5-1/4" 11.1/2' 8.1/2" S' 1' 1' 4.1/2" 1/2' 1' 3' 3' 159 -"HBISSN 155 IS.S 9S0 144 125 41.1/4' 18.3/4- 19.1/8- 31.1/8' 10' 2.3/4' S- 5-1/4' 11.1/1' 8.1/2 5' 1' 1' 4.1/2- 1/3' 1- 3' 3" 166 N}l@199N 199.9 19.4 95.0 18S 161 11.1/4' 11.3/4' 19.1/8' 31.1/8' M1/2'3' ,1,-1/4' 6' It' 9.1/2' 6.1/4' 1.1/2' 1-1/2' 4.1/2' 1/2' 1.114' 3' 3' 175 W08205N-285 28.5 95.0 264 229 41.3/4' 18.3/4' 21.1/8' 31.1/8' 15" 3' 3.3/4" 5.1/4' 12.114" 11' 6.1/4' 1-1/2' 1-I/2' 6.1/2' 1/2' 1-/4' 3' 3" ]L4 W11839911^399 60 94.0' 3771 328 43.1/4' 25.1/4' 11.7/8' 34' 3.1/2' 4.1/4' 22.1/2"1 18' 8-7/8' 12.1/2' 9.1/4' 2' 2- 21.1/2"3/4' 1.1/2' 4- 4 21 - Information subject to change without notice.Change"N"to"L"for LP gas models. The Net AHRI Water Ratings shown are based on a 'Thermal Efficiency% piping and pickup allowance of 1.15.Lochinvar should be consulted before selecting a boiler for installations having unusual piping and 11 Gross Output MBH pickup requirements,such as intermittent system operation,extensive piping systems,etc.The ratings have been determined under the provisions governing forced draft burners. `•10:1 Turndown ratio and top and bottom water connections are not included on W HB399.W HB399 operates with a 5:1 turndown. I ? Most Efficient 2018 1 .. I . ■ ■ 1 1 1 r 1 1 ■ 1 I ■ ti + 'Id { . 4 1 .. T 1 L ■ � ■ 1 ■ ■ ■ AK (4:2 1/ IND US TRIES LTD. MODEL MF300 `PRESSURE PAL'MINI SYSTEM FEEDER 0 The PRESSURE PAL is ideal for feeding and pressurizing closed hydronic systems that do not require cold static fill pressures higher than 170 kPa (25 psig). It is compatible with both water and glycol/water solutions. Perfect for small boiler/chiller systems, snow/ice melt circuits, outside air heating/cooling glycol coils, solar heating systems. FEATURES and BENEFITS ■ 65 litre (17 US gallon) tank for storage and mixing ■ Power supply plugs into any standard 115 VAC outlet ® Diaphragm pump can run dry without damage ■ No direct connection to potable water supply eliminates need for backflow prevention ■ Make-up fluid stored in the feeder tank can be pre-treated ■ Diverter valve allows easy purging of air on initial start-up, and manual agitation of solution ■I Prevents major floods- in the event of system rupture, only the contents of the tank will be pumped into the system ■ Provides leak detection-dropping fluid level provides immediate notice that the system has developed a leak ■ Fluid drained for service can easily be put back into the system ■ Fluid level switch shuts the pump off if the storage tank level gets too low ■ Auxiliary dry contact included for remote low pressure alarm (alarm optional or by others) Represented By: AXIOM INDUSTRIES LIMITED 2615 WENTZ AVENUE SASKATOON,SK S7K 5J1 TOLL FREE:(877)651-1815 PHONE:(306)651-1815 FAX:(306)242-3373 1 1 1 i - _ r INDUSTRILS LIMITED MF300 HYDRONIC SYSTEM FEEDER TECHNICAL INFORMATION WEIGHT- 6.8 kg,15 lbs. Mini-Feed ELECTRICAL -------------------- �_.. ... Fused Power supply adapter 115/60/1 to 24 VDC 36 in Rated 50 watts AC 900 mm LED Power Light 32 in 800 mm PUMP PERFORMANCE 0.04 I/s(0.7 gpm)@ free flow Self-priming up to 1.2 m(4 feet) I 11.75 In 300 mm SPECIFICATION Depth In 300 mm Clearancesnces-Sides and Top-12 In 305 mm Discharge 112"FPT Hydronic system feeder shall be AXIOM INDUSTRIES LTD. Model MF300. System shall include 65 litre (17 U.S. gallon)storage/mixing tank with molded-in level gauge, 125 mm (5")fill/access opening and cover; pump suction hose with inlet strainer and check valve; pressure pump with fuse protection; low fluid level pump cut-out float switch; manual diverter valve for purging air and agitating contents of storage tank; pressure switch with snubber and two sets of SPST dry contacts, each individually adjustable from 70 kPa (10 psig)to 170 kPa (25 psig) cut-out pressure; factory cut-out pressure set to 104 kPa(15psig); and liquid filled pressure gauge. Unit to be c/w fused power supply adapter with LED power indicator light, 115/60/1 to 24 VDC 50 watts AC, supplied loose for field installation. Feeder shall be compatible with glycol solutions of up to 50%concentration. Pump shall be capable of running dry without damage. The second set of contacts in the pressure switch shall be wired to a terminal strip for use as low pressure alarm contacts for remote alarm circuit supplied by others.Unit shall be completely assembled. ACCESSORIES ❑ RIA10-1-SAA—Low Pressure Alarm Panel c/w Remote Monitoring Dry Contacts and Selectable Audible Alarm LIMITED WARRANTY The MF300 is warranted against defects in materials and workmanship for one year. Project Location Consultant Contractor Unit Tag Sales Agent �+ I 1 ,. ., Northwest Plumbing Contractors,Inc. 8/21/19 3810 166"' PL NE #123 Arlington, WA 98223 For: SHARP DESIGN &BUILD LLC 360-653-7224/509-665-3631 NORTHPCO55KB We propose to furnish all materials and labor including the following fixtures and valves necessary to complete the plumbing for: Bid #: 591-06 Name/Address: ROYAL STORAGE SMOKEY POINT NO FIXTURE DESCRIPTION VALVE/FAUCET I FIXTURE COLOR 1 TOILETS: KOHLER K-96057-0/SLOAN 3250400 FLUSH. TOILET W/OPEN FRONT SEAT WHITE 1 ** GERBER MAXWELL EB W/WOOD SEAT WHITE 1 LAVS: KOHLER K-2005-0 WALL MT MOEN L4621 CHROME WHITE 1 ** KOHLER K-2005-0 WALL MT SLOAN 3335061 CHROME WHITE TUBS: SHOWERS: 1 KIT.SINK: ELKAY DSE3322 DELTA 300 CHROME SRS 1 MOP SINK: MUSTEE 63M MUSTEE 63.600A CHROME WHITE DISPOSAL: DISHWASHER: install owners with hot water supply and drain ICE MAKER BOX WITH VALVE: with hammer arrestor BAR SINKS: CLOTHES WASHER HOOK-UP: LAUNDRY TRAY: 1 WATER HEATERS: RHEEM PROE6-I-RH-POU ELECTRIC 1 PRESSURE REDUCER 1 KEYSTOP FROST FREE HOSEBIB 2 FLOOR DRAINS: IN MAIN OFFICE BATHROOM/MOP SINK AREA 2 FLOOR DRAINS: FOR BOILERS IN STORAGE AREA (CONNECTED TO STORM BY OTHERS) REMARKS: Does not include sales tax. Does not include any permits. Drains and vents to be ABS. Water service in ditch by others. All trenching and back-fill by others. All pipe insulation by others. *NOT INCLUDED: +$100 PER FIXTURE FURNISHED BY OTHERS FOR INSTALL COST* ACCEPT PROPOSAL (initials) for the sum of- Conditions of sale: All past due accounts subject to 1.5% monthly service charge. Buyer agrees to pay all costs of collection of past due amounts. ,�, I . _ i _ - - � 1 i i i _� i ■ i i _ - � • CITY OF ARLINGTON INSPECTION CARD No building construction shall be commenced until permit holder INSPECTION RECORD SHALL or his agent has posted this Inspection Record Card in a REMAIN AT JOB SITE conspicuous place on the premises. OWNER: Premier Pacific Properties LLC CONTRACTOR: The Janes Company Inc JOB ADDRESS: 17011 59th Ave NE Bldg A LOT NUMBER TYPE GROUP NATURE of WORK: Plumbing USE of BUILDING: PERMIT No: BLD-2789 DATE ISSUED: INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB DEPARTMENT INSPECTION DATE(S) PASS FAIL INITIALS FOOTING BUILDING FOUNDATION (360)403-3417 UNDERFLOOR ISHEARWALL PLUMBING(groundwork) ROUGH PLUMBING GAS PIPING ROUGH HEATING&VENTILATION FRAMING INSULATION WALLBOARD(SHEAR/RATED WALLS) CEILING GRID STRUCTURALSLAB CROSS CONNECTION CONTROL IN PREMISE (360)403-3417 GRADING TEMPORARY TECSP ASBUILTS APPROVED MAINTENANCE BOND STORM DRAINAGE SYSTEM PAVING,SIGNAGE&MARKINGS LANDSCAPING CONDITIONS ONSITE UTILITIES WATER ONSITE UTILITIES SEWER Sewer OFFSITE UTILITIES WATER (360)403-3608 OFFSITE UTILITIES SEWER SEWER PRETREATMENT Water CROSS CONNECTION CONTROL PREMISE (360)403-3526 SIDE SEWER/CLEANOUT/FINAL WATER SERVICE INSTALLATION WATER SERVICE FINAL (360)403-3417 HYDRO/FLUSH UNDERGROUND"'INCL FDC FIRE ALARM /AUTOMATIC SPRINKLER HOOD SUPPRESSION SYSTEM FINAL FIRE WALK-THROUGH (360)403-3417 FINAL INSPECTION ALL SIGNATURE BLOCKS MUST BE COMPLETE 5 MATCH LINE s•4• 7 A2.0 Az+ 5 6 3d� 711(10 71x10 - 10x10 AX10 E=l r `— m 2 5 3 10x10 10x10 10x10 10x10 - 10x10 10x10 10x1D 10X10 10x10 10x10 10x10 tOx10 ioX10 10x10 10x10 10x10 10x10 10x10 10x10 10x10 10x10 10x10 ' L 1T - -- - MANIFOLD j Os 1hr FIRE WALL r O -thr FIRE WALL. - � - 8 I 5x5 ------ --- _ _ _____ 5x5 J x Xw- 10x10 10x10 10x10 10x10 10x1D o - a 5x5 1 10 1Dx1D 1Dx1D 10x10 5x5 -t E? 10x10 6 'o 'o o 'o 'o c 6 0 0 'o 0 0 0 0 o w w 6 can x 3 5M5 � � � V, w w � Vms YI � o N w w ------------------ WTS O O OFFICE ulaf 10x10 10x10 10x10 y —- - �UNI-S " 8• w w w w — -------------- O w w w 10x10 10x10 10x10 1Ox10 10x10 1OX10 - ao S•B. s 1-Q1S�. _�Q1S� -- - - -'- ---- - 8•� 8.8' 6! 84r 88 8$ 8'4r 8B' 88 8$ 8$ 88 88 88 S8 8 5'B' 9'�" 9,�. g_,. I p-0• B'-B" gd B'11° a'-B' Lv-r g itr ,'-0• p-0• 1'•+1' •• � . t,q• 1.1' 14' ,.�. ,•�. ram• ,= .{• 1'd• 1,-0• r•4• WIE 11,�. 1'4. 1••4' 1� A1 400 4 S. _ 1.,,,,,..�—g 2 — m �0 , BLDG. AAWEST PLAN 40� � os. tat FLOOR OFFlCE � p$_ OS n n a2.o SCALE 1/16"=1'-0" 6 5 MATCH LINE 5W4r 5 10 10 71x10 10x10 10x10 10x10 10x10 10x10 10x10 10x10 10x10 1000 10x10 10x10 1000 10x10 10x10 1000 10x10 10x10 10x10 10x10 10x10 10x10 10x10 10x10 10x10 10x10 10x10 10x10 10x10 10 1 - 1hr FIRE WALL r - 6 ...-- — 5x5 - 6 10x10 1 6 4 X 10x10 10x10 10x10 10x10 10x10 10x10 _ 10x10 1Ux10 10x1D 0 10x10 0 5xs q o MIS o 0 0 0 0 0 0 0 w o o {y 5x5 0 0 8 cares 5 VRp B' I o xo 0 0 0 v, w w w c'n c'n 1000 10x10 Q 10 111 110 1Ox10 10X10 r e'a' g$. se- ss' ,�, °'•e' s$' era• B'a- g'B. y a• B'�° 9 a - e --a�• _ B B e'B" 9'A" a'A' g 8' C4r V-r g 8 8 g• W-8 8 B' a t!• a'B" g-0' 1; r 4 r s r4. 1. . V r ,.,,. ._ 1'-0" 1'•4" r•4 1'-0. 1'4` 1'd4• rA. p 4• p 4• ' 1 1 10-0 _ M-0 40 4r D& 08. 1 40'-0' D8. 4oa WiE 1 47 W-0 — 41y4r 08 2 BLDG. "Arr EAST PLANpB A2.0 SCALE 1/8"=1'•0" CITY OF IARLINGTON 3 12 �2 BUILDING DEPARTMENT L P�PP, ROVED - - - eceive DATE BY SEP 12 2019 NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR ( Z C7�I OFFICE COPY u14bI•J A 7 A2.+ H,14FURNACE F------ CLOSET i I I I 4rY w O / I ( 2 3 , 10x10 10x10 ----------- —————— ------------------ I I � IIII,,IIII HA9L F WALL 4-2"A—.F.A11(. —`——'`— —jI11 ,5`x_T5 CLOT5x5 4-- +z OFFICE —————— o + MOP 3 _x �. II1I1 FLOOR DRAIN -------------------- r-- 1 s TO ' oa ......1- w � I � L————————————— —---- — ----- i -CS �� ----------• — in lk a.° 20'-8" 2nd FLOOR OFFICE a2.+ SCALE,/8"=1'-o'� , 1st FLOOR OFFICE n2.0 SCALE 1/8"=1'•0" 3 A'1 Received SEP, 12 2019 7 11 A2.1 A2 D s 5 MATCH LINE WOW wwmw 2 s 3 10x10 10x10 1000 10x10 71x10 71x10 10x10 10x10 10x10 10x10 1Dx10 10x10 10x10 tOx10 10x10 10x10 10x10 10x10 10x10 10x10 lox10 lox10 1000 1000 10x10 10x10 10 9 7100 10x10 r V 6 111 FIRE WALL. 111tiNROLO lOs 1hr FIRE WALL. 6 ]5a5 9td cn xn cn cn rr cn cn cn 8 � SxS ut x s 1 10 10x10 10x10 lox10 10x10 10x10 10x10 1ox10 10x10 10x10 0 6 0 0 0 0 0 0 0 0 0 o x 5x5 N o q o o x g texts o OFFICE O �i3 v,x1s airs 8 s ------- 6• 4 if 3 T f eT "' a lox10 10x10 10x10 10x10 10x10 10x10 " " " " " 10x10 10x10 10 10 Q 10x5 51-87 3 _—.._ __ 5__ .- _—._ ---.-- 7•C $ @4- $a• S p- a41 as a.S• ao a41 1 I_a8 4ab 1�• 1�g� ty��' +w�6 t 4ad 1 4a 1 Ae� 1-0�g t'4ga t 16 a /4'BA' 1'ig8 1 4a8' ri46�' t 49$' t AaS 1 Aat +' 8 8• 5 4'aA 1 14• 14• 1••4- 14• 14• 14• ?�' 1'-0' 1'•4• _ 2 1 1 � 1 'M E 1 1s[FLOOR OFFICE 3a-0• 40•-0• 4US- DS. 40 4Q''• a scucire•.ra Ds. oS. BLDG. "A" WEST PLAN Az.o SCALE 1116"=1'-0" MATCH LINE 5W,, 5 5 5 { I 71 to 71x10 10 10x10 10x10 10x10 10x10 10x10 U5 10x10 10x10 10x10 1000 10x10 10x10 10x10 10x10 1000 10x10 10x10 10x10 10x10 10x10 10x10 10x10 10x10 10x10 10x10 tOx10 10x10 10x10 10x10 Os III FIRE WALL. 10 t a - — -- _ ._... s 5x5 i 6 s 4 X x 10x10 10x10 10x10 lox10 10x10 lox10 10x10 10x1D 10x10 10x10 10 0 10x10 � � � curs 6 0 0 0 earn j tam o' o s o 0 0 1 N ZA � to EA toCA 10 10x110 0 10x1D 10x10 10x10 10x10 Q, 7 • 14x5—, - _... _ _._---—........ tI a'a° a s 4 a4r ea a e- a:e• ae• as ata• a e e a s a a• a41• g ga a s a-0• sa• e•-a g�• r a a a a s asa o1.4' IL a •-0" 1'-0" 1'-1- Wig 110 4o W-W 417-W 4V 40' -o' -0" 40'-0 C41' 4a ta4r s. os. °& "�' s BLDG. "A" EAST PLAND9 os. D A2.0 SCALE 118"=1'-0" o �2 CITY OF ARLINGTON BUILDING DEPARTMENT °— T APPROVED 1 DATE_ BY --/,�2 Received NO CHANGES AUTHORIZED UNLESS APPROVED BY THE SEP 12 2019 BUILDING INSPECTOR 0 13 G(im P �✓�7i��G1 AY.1 4A' FURNACE ----- -------- --- — — --- CLOSET I;II II, 2 O t �44 LuI 0 ---------- ' 10x10 10x10 - ----------- ------ 1 _ __...._......,. -=-- -- ,o I I HALF WALL 42"A.F.i' I 1 3. n Cl0 . 'k '5x5 3 j` ON 15x5 I I II q - -------- ` -----------_____ ir O_ 44. OFFICE FLOOR DRAINI H 3 3 1 I ———————————————————— r--- UNI- X I • I � I I 3 �C? � I _ I 1 1 uuii I I I L-------------- ------- �`- - ----- 4 , e A6.0 2nd FLOOR OFFICE , 1st FLOOR OFFICE a2t SCALE 1/8-=1'-0" AZO SCALE 1/8"=1'-0" / O _ 4'1 w AST y F n + MS 1l' P a� �S ��M IL Al OFFCOPY ICE CITY OF ARLIN G T ON BUILDING DEPARTMENT APPROVED DA1FE*WLq BY NO CHANGES AUTHORIZED UNLESS APPROVED BY THE i BUILDING INSPECTOR E CO PY Received SEP 12 2019 "i[,�I w A TE/Z a af't f �i S �Nks p��2S1 .° 9 L0,V r Fiarr f�ta.e �ta�n�l`s � �nP%Q V,paTgis.� J=�arT ,jC LAS E Y� ys- N< r __ f/ t kiC CITY OF ARLINGTON BUILDING DEPARTMENT Received APPROVED SEP 12 2019 VI, � le of-4J;,k DATE BY VA V?nOA NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR w As•rE k" of ,v-0 F t h 5 UNA �w�9lSTr►//LS 10 RR � I~ 3 CITY OF ARLINGTON j BUILDING DEPARTMENT j APPROVED DATE EW tO 3� NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR y� SOB COPY Received • SEP. 12 2019 p417 zm(b ATE/L - a Fez 3A Yy r, t o04e f�`O$ S►r1 i� LQV �t�N.IrR� mP►i w �t n INcg V PSTAI�S �Ias `� V.1� 00 YI, Y� � 3A 3/w CITY OF ARLINGTON BUILDING DEPARTMENT Received APPROVED ,`� SEP_12 2019 DA BY L-, �iq gn(M S N NO CHANGES AUTHORIZED Fi/ds�- fz�•L UNLESS APPROVED BY THE BUILDING INSPECTOR m --.0 O 3 O co =r r < CD Z 00m C � n. cn � ' rJ COMMERCIAL PLUMBING . , PERMIT APPLICATION Department of Community&Economic Development City of Arlington • 18204 59th Ave NE•Arlington, WA 98223 • Phone (360)403-3551 WHEN is a PLUMBING PERMIT REQUIRED? The City of Arlington requires a plumbing permit before a plumbing system or fixture is installed, altered, or remodeled. This also includes replacement of a Hot Water Tank. The City of Arlington does not require a permit to stop leaks or clear stoppages, unless the piping being repaired is altered or replaced. PLUMBING PLAN REVIEW IS REQUIRED FOR THE FOLLOWING PROJECTS 1. New Commercial Buildings 2. New Multi-Family Buildings 3. Roof Drains and Overflow Systems 4. Tenant Improvements 5. Installation of Medical Gas Systems 6. Installation of Commercial Kitchen's and Deli's 7. Installation of Grease Traps 8. Installation of Grease Interceptors 9. Installation of Sumps 10. Installation of Cross Connection Backflow Devices SUBMIT TWO (2) COPIES OF THE FOLLOWING FOR PLUMBING PLAN REVIEW: ❑ Plumbing plans or drawings. (Minimum plan size is 18" X 24" scale, %" scale for details.) ❑ Provide one set of plumbing drawings maximum size 11" X 17" ❑ Size of sanitary and potable water systems. ❑ Location, type and specifications (cut sheets) of proposed fixtures and equipment. ❑ Riser diagram of waste and vent, potable water and rain water systems, including sizes. ❑ Medical gas piping riser diagram indicating type of gas, storage room and size of piping. ❑ Location and type of all backflow assemblies for each fixture. I hereby certify that I have read and examined this application and know the same to be true and correct and I am authorized to apply for this permit. 6/16LP Page 1 of 3 COMMERCIAL PLUMBING PERMIT APPLICATION lIN Department of Community&Economic Development City of Arlington - 18204 59th Ave NE -Arlington, WA 98223 - Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO (2) SETS OF CONSTRUCTION DRAWINGS, AND TWO (2) SETS OF FIXTURE SPECIFICATIONS (CUT SHEETS). CALCULATIONS ARE REQUIRED FOR GREASE INTERCEPTOR/F APPLICABLE. Type of Permit: New Installation 0 Addition/Alteration Industrial Project Address: l l b i ) S9 7W A t,6 W Parcel ID#: Lot#: AL 8 "A of Subdivision: 'V/'+ Project Description: fZc-,`,A 4-- Valuation: Owner: S ice' 4"/,a, Phone Number: 'Mc;' 71,0-- Address: I.U-C'C i�i�� 5 - ^jam City:U S>E'"F S State: Zip Code: 9 92-Ci' Contact Person: >° Phone Number: Cell Phone: E-mail: ®, Ce',-r Address: /3 V iW 5T City:LA ACF -Si 45-6 State: IV F) Zip Code: 9 C 2 S ft Contractor: ACMLJE-Vr 11u4d2N6 Ca.yyLgZp,LS oniC Phone Number:_-T&P- SSZ-722S1 Cell Phone: Email: Address: 381IV l"7w AWE JO 123 City: Age'^iS7raN State: A/4 Zip Code: 9 8 2 23 Contractor License Number: daxml°0 e)-s-'ry-a Expiration Date: .10-3-/9 Please indicate number of fixtures: �c o�tE rC Water Closet .. Floor Sink Sump Hose Bibb Miscellaneous Lavatory 2, Laundry Tub� Washer Water Heater Grease Trap Urinal Interceptor Sink / Med Gas Drinking Fountain Floor Drain 3 Dishwasher Backflow Shower Other IMO�RE�T QA/1�.I /../ /cirRwf ACC �ieh e6z-Li qZ- .75y-17o2 CMS//�: go � Jfl../CSC6..iP�1��Y.Gds.a $2'21 4'17V .4vE w s! ?o �++�ae�c7t, e�f �!• 9 �Zt75 co-47, .41e % .-- A-4CBSC ) 079ts:X EYE? +C1-► 7F-; l2- 1s'./'9 6/16LP Page 2 of 3 COMMERCIAL PLUMBING PERMIT APPLICATION Department of Community&Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 •Phone (360)403-3551 PROPOSED BUILDING USE New Commercial ❑ Restaurant ❑ Automotive Based ❑ Commercial Addition/Alteration ❑ Office ❑ Machine Shop ❑ Industrial ❑ Medical ❑ Other: CROSS CONNECTION Please check all appliances that are proposed or are permanently connected to the water supply. Ice Machine ❑ Dialysis Equip. 0 Air washers 0 Swimming ❑ Fire Sprinkler Pools Coffee Steam Sprinkler Urn/Espresso ❑ Hydrotherapy Equip. ❑ Generators ❑ Hot Tub/Spa ❑ w/chemicals ❑ Carbonated Bev. ❑ Dental Equip. ❑ Dye Vats ❑ Aquarium ❑ Lawn Irrigation ❑ Fume Hoods Laboratory Equip. ❑ Pressure ❑ Decorative ❑ Well on Washers Fountain property ❑ Degreasers Autoclave/Sterilizers ❑ Cooling Towers ❑ Other: WASTEWATER DISCHARGE 1. Does the plumbing system currently have a grease interceptor? ❑ Yes i�l No ❑ Don't Know Date grease trap/interceptor was last cleaned (provide service record): 2. Does the plumbing system currently have an oil/water separator? ❑ Yes L1 No ❑ Don't Know 3. Date oil/water separator was last cleaned (provide service record): 4. Is water used in the business process (washing, rinsing, cooling)? ❑ Yes �l.l�cr_N.o ❑ Don't Know 5. Does your business require a NPDES permit? ❑ Yes LS No ❑ Don't Know I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-described property will be accordance with the laws, rules and regulation of the State of Washington. �r9_ i9 Applicants Signature Date V T�©Y n v l-,'0,0t-p Print Applicants Name FOR STAFF USE ONLY �,1 Received Permit# Accepted By Amount Received Receipt# Date 9 ive 6/16LP Page 3 of 3 S I 1 ;n� �, �6!, � i! -��', G i'� ` 'J' �o, ,.1 i� � �� 'F `ter .s.` �� �' � I_k. 1��! �. ,, ' ,� ` � 1' „' ,! .�..+ � u o,y,r.� .,� �� � �i. -� '�� �' � J, r�, i .. .< { , IC�i 'If. ,�,��� I + �� - ' y 0;4 ' �`�., `�Taa _. �f :i..7- � �_`1 "� i �� - �: � � �r�.�'` 4 t�_ gyp' �:r �Y T,' � � rt Y!� S�'_s' I 1 <�1����' 1. i T '� � ._,t.�_� 1 �. ltJi '°� �,: 1�� .�. {} ���_�, � � K� ( � �, d�, � �, i � .� ��� , � � . ,, x .�ti_1 � i �YY ` I � �:� '" & (l�� .��t�, - o f FIRE TUBE BOILER ` 001+ r z 0 p O © _ a Y KNIGHT FEATURE'S V UNIVERSAL VENT CONNECTOR f I© .11lOwvS iiii�'rlsy uI,I��IIdIIDn ul nulluplil ��•n[nlB lel lrll, I r' FIRE-TUBE HEAT EXCHANGER Low plI q'mll''d I olj'.'IV('-.--)I'purnp opoi.11lon l otit',:IIId pI'DIn111�°.Im1,+II�IIron flr:-Xlblht}',wllil!• futhl,• ,.Ili rulIo�lon SMART SYSTEM USER INTERFACE +pialII f_II��ikII ;od1l iior IIIh-I i;Itc o"ltI)nlUlti(o4i :ilar_nu;Uc dlspl'I� 10:1 MODULATION TURNDOWN r z _ SdVP nlonl�y un Iul�l cotit 2 p cr p 5 ELECTRICAL OUTLET(not shown on WHB) LL r Plugavall hlc'fur�,vgrrt ilghl or toliilru,Ul�'pump. z Y m 5 LOCH-N-LINK"' USE, PROGRAMMING Y aliuw�.lii�S,.Ivinl'�I(p.n',IrnOlel s onlu;:USR ii�Ivr�lug uut i+1 ,�diliDlhnl�oL ,Ilr INSTALLATION FLEXIBILITY rDp and lur IYIc AIlIE. lop 8nd i0, Sick U011111 connection,for the KFIb loi:,,i�v r�tr.-filler;, LOChinvar.co 1 SU(II a',iI cast I'On Oflldir Ncy I�pg��Uk•. BOILER CONTROL FROM ANYWHERE The Industry's most advanced boiler control system now includes the CON*US'Remote Connect a option and Loch-N-Link* USB drive programming feature. See next page for a complete list of SMART SYSTEMTM functions and features. From wherever you are,the CON*US option lets you use any internet-capable device to link up with the SMART SYSTEM on an unlimited number of KNIGHT boilers.With CON*US,you're always in touch and in control.Optional CON*US control board is sold separately. » DO REGULAR CON*US CHECKS FOR ALL YOUR KNIGHT CUSTOMERS, AND C0N'Xe US LET THEM KNOW YOU'RE MONITORING THEIR BOILER'S PERFORMANCE. /� » ADJUST SETPOINTS, DOMESTIC HOT WATER, RESET CURVES, PUMP DELAYS AND MORE, USING THE CON*US INTERACTIVE DISPLAY. S,anU4y » STATUS ALERTS VIA TEXT OR E-MAIL LET YOU KNOW WHEN A KNIGHT BOILER NEEDS ATTENTION. r..� .� App Store THE ULTIMATE IN BOILER CONTROL - YSTEMfy AND MONITORING The backlit, user-friendly LCD display provides diagnostic information and system status in real words,not codes Including: SET-UP WIZARD SETUP WIZARD For fast and easy programing. i BOILER PUMP TYPE: VARIABLE RAMP DELAY Six steps of modulation to extend runtime and reduce cycling. T 47.'� _ ( LOCH-N-LINK ° Save parameters on a USB drive and take them with you for future use. VACATION MODE Tell your boiler when you are out of town to save energy OUTDOOR RESET WITH BOOST Automatically change the set-point according to weather conditions. MODULATION FACTOR Fine tune boiler performance to be more or less aggressive depending on the application. VARIABLE SPEED BOILER PUMP CONTROL Keep the same Delta T at all firing rates to save electricity and increase performance. THE BEST New features include: SET-UP WIZARD VARIABLE SPEED ECM PUMP UNIVERSAL VENT CONNECTOR WITH ANALYZER PORT 110V CONVENIENCE OUTLET PARTS COMPATIBILITY BETWEEN FLOOR AND WALL MODELS AUTOMATIC PARAMETER RESTORATION WHEN CONTROL IS REPLACED WHB KNIGHT WALL MOUNT TM SMART SYSTEM FUNCTIONS AND FEATURES SMART SYSTEM" FEATURES »Smart System Digital Operating Control *Low-Voltage Terminal Strip »Vertical&Horizontal Direct Vent Multi-Color Graphic LCD Display w/Navigation Dial, Domestic Hot Water Recirculation Pump Start/Stop PVC,CPVC,Polypropylene or SS Venting up to 100 feet Soft Keys and loch-N-Link•USB programming 24 VAC Device Relay »Universal Vent Adapter »Three Boller Setpolnt Temperature Inputs Configurable Proving Contacts Built-in Combustion Analyzer Port Plus Domestic Hot Water Prioritization Flow Switch Contacts a Smart System Control »Built-in Cascading Sequencer for up to 8 Boilers, Alarm on Any Failure Contacts »Condensate Trap with Cascade Redundancy Runtime Contacts »ECM Variable Speed Boiler Circulating Pump Multiple Size Boiler Cascade DHW Thermostat Contacts »110V Convenience Outlet Lead Lag 3 Space Heat Thermostat Contacts »High Altitude Models Available Efficiency Optimization System Sensor Contacts »Other Features Front End Loading Capability Domestic Hot Water Tank Sensor Contacts Automatic Reset High Limit »Outdoor Reset Control with Outdoor A r Sensor Outdoor Air Sensor Contacts Adjustable High Limit w/Manual Reset Programmable for Three Reset Temperature Inputs Cascade Contacts Boiler Circulating Pump »Programmable System Efficiency Optimizers 0-10 VDC BMS External Control Contact Zero Clearances to Combustible Materials Space Heat Night Setback 0-10 VDC Boiler Rate Output Contacts 15-Year Limited Warranty(See Warranty for Details) Domestic Hot Water Night Setback 0-10 VDC Variable Speed System Pump Signal Input 5-Year Limited Parts Warranty Anti-Cycling 0-10 VDC Signal to Control Variable Speed Boller Pump »Firing Codes Outdoor Air Reset Curve Modbus Contacts M9 Standard Construction Ramp Delay ))Time Clock M7 California Code Modulation Factor Control »Data Logging Boost Temperature&Time Hours Running,Space Heating OPTIONAL EQUIPMENT »Four Pump Control Hours Running,Domestic Hot Water CON*US'Remote Connectivity System Pump with Parameter for Continuous Operation Ignition Attempts Modbus Communication Boiler Pump with Variable Speed Control Last 10 Lockouts BACnet MSTP Domestic Hot Water Pump ))Maintenance Reminder Flow Switch Domestic Hot Water Recirculation Custom Maintenance Reminder with Low-Water Cutoff w/Manual Reset&Test »Domestic Hot Water Prioritization Contractor Contact Information Alarm Bell DHW tank piped with priority in the boiler loop Installer Ability to De-activate Service Reminder Concentric Vent Kit DHW tank piped as a zone in the system with the pumps »Low-Water Flow Safety Control&Indication SMART SYSTEM-PC Software controlled by the SMART SYSTEM »Password Security Condensate Neutralization Kit DHW Modulation Limiting »Customizable Freeze Protection Parameters BMS Gateway to LON or BACnet IP Separately Adjustable Space Heat/DHW Switching Times STANDARD FEATURES Multi-Temperature Loop Control »Building Management System Integration I)ENERGY STAR Most Efficient Product Sidewall Vent Termination 0-10 VDC Input to Control Modulation or Setpolnt 1)95%DOE AFUE Efficiency(WHB 55-285) Wireless Outdoor Sensor 0-10 VDC Modulation Rate Output *Modulating Burner with up to 10:1 Turndown LP Conversion Kit 0-10 VOC Input to Enable/Disable Call for Heat Direct Spark Ignition ,)Access to BMS Settings through Graphic LCD Display Low NOx Operation »High Voltage Terminal Strip »ASME Stainless Steel Heat Exchanger 120 VAC/60 Hertz/1 Phase Power Supply 30 PSI ASME Relief Valve Three Sets of Pump Contacts a MNPT Top and Bottom Water Connections (WHB 55-285 only) KNIGHT BOILER DIMENSIONS AND SPECIFICATIONS FRONT G LEFT SIDE I Air Intake ------------ Walter Outlet 1 �.. AC Outlet Flue Vent TOP - O - Gas inlet 0 w O JA Water 43• /11 , C - - - Met E 8 + 1 B -----9 19, \\-Hi Votage Electdca NO F low Voltage I K Eleddcd(onnettion u e g t 160 H -- I - Condensate Drain FLOOR MOUNT i Input MBH Heating Model Cdpacity Net Gas Water Air Vent Shipping I KHB04511 S5 8,�95.0 S! 44 3-1/2' 1344' 6' 2.3/4" 37.2/3' 13.1/2' 8.1/3' 10.1/2' 15' 32.1/2' 8.1/3" 1/2' 1' 2' 2' 160 K118085111 85 8.5 95.0 79 69 3.112' 13-1/4' 6' 2.3/4' 37.213" 13.1/2' 8.1/3' 10.1/2' 15' 32-1/2' 8.1/3' 1/2' 1' 2- 2' 165 KHBlION 110 II 9S.0 102 89 2.3/4' 14.3/4' 7.1/2' 2.3/4' 38' 14.1/3' 9.3/4' 10.1/2' IS' 33' 8.1/3' 1/2' 1' 3' 3' 170 KNBISSN 155 13.5 95.0 144 12S 2.3/4' 14.3/4' 7.1/2' 2.1/2' 38' 14.1/3' 9•3/4' 10.1/2' IS' 33' 1-1/3' 1/2' 1' 3' 3' 175 KH8199p 199.9 19.9 95.9 IBS 161 3" 15.1/2' 7-1/2' 2.1/2' 311-1/3" 111LIQ•1/2' 11.1/2' 15' 33' 8.1/3" 1/2' 1-1/"4 3' 3' 19S KHO285K 265 28.5 95.0 264 229 3' 1S•1/2_ 7.1/2' 2.11 38.1/3' 14.1/3 10.1/2- 11.1/2' 11' 33- 8.1/3' 1/2' 1-1/4' 3' 3' 20S RIGHT SIDE TOP HigghVolloge BOTTOM iA �` yj Ike Vent 9edd(d(onnedion Low Voltoge F I H Air Intake H(d(onnedion Water Met_ - AC Outlet Tt 000 B o0 E O A l • -} m O I �1c� J I Condensate E1rdn G K ' Gas Met l �L B _� M - N � Water Outlet WALL MOUNT Q= C Input CapacityModel k WHB055.H 5S 8.2 95.0 51 44 40' 18.3/4' 16' 31-1/8' 8-1/2' 3-3/4' 4.1/2' 1.1/2' 7-1/4' 9j/8' 3.1/2' 1.1/2' 1.1/2' 6- 1/2` 1. 2' 2' Icy WH8085N 85 8.5 9S.0 79 69- 39.3/4' 18.3/4' 16' 31.1/8' 8.1/2' 3.3/4' 4.1/2' 6-1/2' 1.114' 8.7/1' 3.1/2' 1.1/2' 1.1/2' 6' 112' 1' 2- 2- 142 Will IION 110 11 95.0 102 89 41•1/4' 19.314' 19' 31.1/8' IT 2.3/4' 5' 3.1/4' 11.112' 8.1/2' S' 1' I' 4-1/2' 1/2' 1' 3' 3' 1S9 "YLh 155111 1SS 15.5 95.0 144 125 41.1/4' 19•3/4' 19.111' 31.1/8' IT 2.3/4' S' 5,-1/4' 11.1/2' 8)/2' S' 1' 1' 4.1/2' 1/2' 1' 3' 3' 166 11(11@199N 19M 19.9 95.0 I8S 161 41.1/4' 18-3/4' 19•i/B' 31.1/8* 10.1/2'2' 5-114' 6' 11' 9-1/2' 6.1/4' 1.1/2' 1.1/2' 4.1/2- 1/2- 1.1/4' 3- 3' 11S WH0283N 285 26.5 9S.4 264 229 41.3/4' 1 B-3/4" 21.1/8' 31.1/8' 15' 3' 3.3/4' S•1/4' 12.1/4' 11' 6.1/4' 1.1/2' 1.1/2' 6.1/2' 1/2" 1.1/4' 3' 3' I84 W0839911-'399 80 94.0- 3770 328 43•1/4' 25.1/4' 21.7/8' 34- 3.1/2' 4.114' 22.1/2'3-7/B' 9-1/8' 12.1/2' 9.1/4' 2' 2' 21-1/2'3/4' 1.1/2' 4' 4' 213 Information subject to change without notice.Change"N"to'L"for LP gas models. The Net AHRI Water Ratings shown are based on a "Thermal Efficiency% piping and pickup allowance of 1.15.Lochinvar should be consulted before selecting a boiler for installations having unusual piping and fi Gross Output MBH pickup requirements,such as intermittent system operation,extensive piping systems,etc.The ratings have been determined under the provisions governing forced draft burners. "'30;1 Turndown ratio and top and bottom water connections are not included on WHB399.WHB399 operates with a 5:1 turndown. Lochinvar Ot �A 2018 f" o FIRE TUBE BOILER ; I � z - o J J a I 3 � I z IIII Y r = di Ilk KNIGHT FEATURES V UNIVERSAL VENT CONNECTOR! allow-,loi oasv in5L k,ilion of mulupki vent imLeriak 1 FIRE-TUBE HEAT EXCHANGER Low pi", "ore drop s;rvr on pump opQration co"k,and provid['5 msBallatior,flexibility while IIamle"S steel 6LAILS ok con-otiion. SMART SYSTEM USER INTERFACE A plain Ln,irdi,cod..free niLerl3cc with multicolor' diat;no"lic displ;ry =1 4 10:1 MODULATION TURNDOWN z $iVf'i monCy on IUe CO',l D 0 O i � I p ELECTRICAL OUTLET(not shown on WHB) J PILIL.,;ivoil ibir for work Buhl or c011drn,c1[f`pump. x { z Y m 6 LOCH-N-LINK'" USB PROGRAMMING x ,111ow>for;uvuie of p.ti'unelei5 on[o'+ U513 drive fOi Use at .i dlflerentjob .iLr 7 INSTALLATION FLEXIBILITY iL Top and bottom watei connection loi:Liv A/HB_ lop and Ich sidt,utihly connections for the KHB loi e.isy iotro-7tbn,e„ Lochlnvar.com such 35 a cost iron efficiencv upt;rade BOILER CONTROL FROM ANYWHERE „y The Industry's most advanced boiler control system now includes the CON*US'Remote Connect option and Loch-N-LinkO USB drive programming feature. See next page for a complete list of SMART SYSTEM'functions and features. From wherever you are,the CON*LIS option lets you use any internet-capable device to link up with the SMART SYSTEM on an unlimited number of KNIGHT boilers.With CON*US,you're always In touch and in control.Optional CON*US control board is sold separately. » DO REGULAR CON-X•US CHECKS FOR ALL YOUR KNIGHT CUSTOMERS, AND CON X US�' LET THEM KNOW YOU'RE MONITORING THEIR BOILER'S PERFORMANCE. //�� » ADJUST SETPOINTS, DOMESTIC HOT WATER, RESET CURVES, PUMP DELAYS AND MORE, USING THE CON-X•US INTERACTIVE DISPLAY. » STATUS ALERTS VIA TEXT OR E-MAIL LET YOU KNOW WHEN A KNIGHT BOILER NEEDS ATTENTION. > w., tApp Stor THE ULTIMATE IN BOILER CONTROL � SYSTEmf AND MONITORING The backlit,user-friendly LCD display provides diagnostic information and system status in real words,not codes including: SET-UP WIZARD SETUP WIZARD For fast and easy programing BOILER PUMP TYPE: VARIABLE RAMP DELAY Six steps of modulation to extend runtime and reduce cycling. TE \ , LOCH-N-LINK Save parameters on a USB drive and take ' them with you for future use. VACATION MODE Tell your boiler when you are out of town to save energy. OUTDOOR RESET WITH BOOST Automatically change the set-point according to weather conditions. MODULATION FACTOR Fine tune boiler performance to be more or less aggressive depending on the application. VARIABLE SPEED BOILER PUMP CONTROL Keep the same Delta T at all firing rates to save electricity and increase performance. 'yw THE BEST JUST GOT BETTER New features include: SET-UP WIZARD VARIABLE SPEED ECM PUMP UNIVERSAL VENT CONNECTOR WITH ANALYZER PORT 110V CONVENIENCE OUTLET PARTS COMPATIBILITY BETWEEN FLOOR AND WALL MODELS AUTOMATIC PARAMETER RESTORATION WHEN CONTROL IS REPLACED WHB KNIGHT WALL MOUNT TM SMART SYSTEM FUNCTIONS AND FEATURES SMART SYSTEM" FEATURES •Smart System Digital Operating Control •Low-Voltage Terminal Strip •Vertical&Horizontal Direct Vent Multi-Color Graphic LCD Display w/Navigation Dial, Domestic Hot Water Recirculation Pump Start/Stop PVC,CPVC,Polypropylene or SS Venting up to 100 feet Soft Keys and Loch-N-Link*USB programming 24 VAC Device Relay •Universal Vent Adapter ,)Three Boller Setpolnt Temperature Inputs Configurable Proving Contacts Built-in Combustion Analyzer Port Plus Domestic Hot Water Prioritization Flow Switch Contacts •Smart System Control •Built-in Cascading Sequencer for up to 8 Boilers, Alarm on Any Failure Contacts •Condensate Trap with Cascade Redundancy Runtime Contacts •ECM Variable Speed Boiler Circulating Pump Multiple Size Boiler Cascade DHW Thermostat Contacts •110V Convenience Outlet Lead Lag 3 Space Heat Thermostat Contacts •High Altitude Models Available Efficiency Optimization System Sensor Contacts a Other Features Front End Loading Capability Domestic Hot Water Tank Sensor Contacts Automatic Reset High Limit •Outdoor Reset Control with Outdoor Air Sensor Outdoor Air Sensor Contacts Adjustable High Limit w/Manual Reset Programmable for Three Reset Temperature Inputs Cascade Contacts Boiler Circulating Pump •Programmable System Efficiency Optimizers 0-10 VDC BMS External Control Contact Zero Clearances to Combustible Materials Space Heat Night Setback 0-10 VDC Boiler Rate Output Contacts 15-Year Limited Warranty(See Warranty for Details) Domestic Hot Water Night Setback 0-10 VDC Variable Speed System Pump Signal Input 5-Year Limited Parts Warranty Anti-Cycling 0-10 VDC Signal to Control Variable Speed Boiler Pump •Firing Codes Outdoor Air Reset Curve Modbus Contacts M9 Standard Construction Ramp Delay •Time Clock M7 California Code Modulation Factor Control n Data Logging Boost Temperature&Time Hours Running,Space Heating OPTIONAL EQUIPMENT •Four Pump Control Hours Running,Domestic Hot Water CON*US'Remote Connectivity System Pump with Parameter for Continuous Operation Ignition Attempts Modbus Communication Boiler Pump with Variable Speed Control Last 30 Lockouts BACnet MSTP Domestic Hat Water Pump )Maintenance Reminder Flow Switch Domestic Hot Water Recirculation Custom Maintenance Reminder with Low-Water Cutoff w/Manual Reset&Test •Domestic Hot Water Prioritization Contractor Contact Information Alarm Bell DHW tank piped with priority in the boiler loop Installer Ability to De-activate Service Reminder Concentric Vent Kit DHW tank piped as a zone in the system with the pumps •Low-Water Flow Safety Control&Indication SMART SYSTEM"PC Software controlled by the SMART SYSTEM ))Password Security Condensate Neutralization Kit DHW Modulation Limiting •Customizable Freeze Protection Parameters BMS Gateway to LON or BACnet IP Separately Adjustable Space Heat/DHW Switching Times STANDARD FEATURES Multi-Temperature Loop Control •Building Management System Integration •ENERGY STAR Most Efficient Product Sidewall Vent Termination D-10 VDC Input to Control Modulation or Setpoint •g5%DOE AFUE Efficiency(WHB 55-285) Wireless Outdoor Sensor 0-10 VDC Modulation Rate Output •Modulating Burner with up to 10:1 Turndown LP Conversion Kit 0-10 VDC Input to Enable/Disable Call for Heat Direct Spark Ignition •Access to BMS Settings through Graphic LCD Display Low NOx Operation •High-Voltage Terminal Strip n ASME Stainless Steel Heat Exchanger 120 VAC/60 Hertz/1 Phase Power Supply 30 PSI ASME Relief Valve Three Sets of Pump Contacts •MNPT Top and Bottom Water Connections (WHB SS-285 only) KNIGHT BOILER DIMENSIONS AND SPECIFICATIONS FRONT G LEFT SIDE � - - Air Intake Water Outlet-� - „".,,� A(Oudet Flue Vent ,O- TOP D - - Gas Wet 0 A Wafer 43.3/8" 0 C -- - Bret 19, High voltage I7ecMcd Hit F �' Low Vollage iN Electricd(nrnettion 16" --� (ondensale Drain FLOOR MOUNTModel - Capacity Net 1 NumberInput MBH Heating s Water Air Vent Shipping ,nn Conn Inlet Size Wt (lbs) KHBOSSH 55 8.3 9S.0 51 44 3.1/2' 13•M' 6' 2-3 4' - 31.2/3' 13•i/2' 8.1/3' 10.1/2' 13" 32•1/2' 0.1/3' 1/2' 1' 2' 2' 160 KNOW 85 8.5 95.0 79 69 3.1/2' 13-1/4' 6' 2.3/4' 37.2/3" 13.1/2' 8.1/3' 10-1/2' 15' 32.1/2' 11 1/2' 1' 2' r 165 UNION 110 11 95.0 102 89 2.3/4' 14;3/4' 1.1/Z' 2.3/4 38' 14.1/3" 9.3A' 1,0.1/2- 15- 33- 8.1/3" 1/2' 1' 3' 3" 170 KNOWN 155 IS.S 95.0 144 125 2.3/4' 14.3/4' 7.1/2' 2•1/2'_ 38' 14.1/3' 9.3/4' 10-1/2' 1S' 33' 8.1/3' 1/2' 1- 3' 3' 17S KN8199N 199.9 19.9 95.0 115 161 3- 15.1/2' 7.1/2' 2.11T _38.1/3' 14.1/3' 10.1/2' lL-1/2' IS- 33- 1-1/3" 1/2' 1-1/'4 3- 3' 19S 82 SN 285 28.S 93.0 264 229 3' 15.1/2' 7.1/2' 1-1/2' 38.1/3' 14-I/3' 10-1/2' 11-I/2' IS' 33' 8.1/3' 1/2' 1.1& 3' 3" 20S RIGHT SIDE TOP HlggliVoltage BOTTOM H - Flue Vent swcd tonnettion low Voltage F Air Intake /tlatricul<onnzdion Water Inlet AC Outlet 000 6 00 F - -�O A - �• --- r D I J { Condensate Dra6t G N B Gas Inlet N�I Water Outlet i WALL MOUNT - �- C Input NumberModel Capacity Ne Gas Water Air Vent Shipping , nn. Inlet Size Wt.(lbs) "11055N 5S 8.3 95.0 51 44 40' 18.3/4- 16- 31.1/8" 8.1/2' 3.3/4- 4.1/2- 6.1/2- 7.1/4' 8.7/8' 3 U2' 1.1/ ' I.1/2' 6' 1/2' 1' 2' 2' 139 WHOO85N 85 8.5 95.0 79 69 39.3/4' 18.3/4' 16- 31.1/8' 8-1/2' 3-3/4' 4-1/2' 6.112' 7.1/4- 8-718' 3•i/1' I.1/2" 1-1/2' 6' 1/2' i' _ ?- 2- 142 W"11ON 110 11 95.0 102 89 41.1/4' 16.314" 19' 31.1/8' 10' 2.3/4' S' 5.1/4' 11•1/2' 8.1/2' S' 1' 1' 4.1/2' 1/2' 1' -WH8155N 155 15.5 95.0 144 125 41•1/4' 18.3/4' 19.1/8' 31.1/8' 10' 2.3/4' S' 0/4' 11.1/2' 8.1/2' S' 1' 1' 4.1/2" 1/2' 1' 3' 3' 166 WHB199N 199.9 19.9 95.0 IBS 161 41.1/4' 18.3/4' 19.1/8- 31.1/8" 10.1/2'3' S-1/4- 6- 11' 9.1/2' 6•1/4' 1.1/2" 1.1/2' 41/2' 1/2' 1-114' 3' 3' 17S WHS28SH 285 28.5 95.0 264 229 41-3/4' I8-3/4" 21.1/8' 31.1/8' IS' 3' 3.3/4' S-i/4' 12.1/4' 11' 6.1/4' 1.1/2' 1•1/2' 6.1/7' 1/2' 1.1/4' 3' 3' 184 WH839911"399 80 94.0• 3171 321 43.1/4' 25.1/4' 21.7/8' 34' 3.1/2' 4.1/4' 22•1/7'3.7/8' 9.7/8' 12.1/2' 9.1/4' 2' 2" 21.1/2'3/4" 1.1/2' 4- 4- 213 Information subject to change without notice.Change"N"to"L"for LP gas models.The Net AHRI Water Ratings shown are based on a *Thermal Efficiency% piping and pickup allowance of 1.15.Lochinvar should be consulted before selecting a boilerfor installations having unusual piping and #f Gross Output MBH pickup requirements,such as intermittent system operation,extensive piping systems,etc.The ratings have been determined under the provisions governing forced draft burners. "10:1 Turndown ratio and top and bottom water connections are not included on WHB399.WHB399 operates with a 5:1 turndown. I 7-018 / INDUSTRIES LTD. MODEL MF300 `PRESSURE PAL'MINI SYSTEM FEEDER The `PRESSURE PAL' is ideal for feeding and pressurizing qP closed hydronic systems that do not require cold static fill pressures higher than 170 kPa (25 psig). It is compatible with both water and glycol/water solutions. Perfect for small boiler/chiller systems, snow/ice melt circuits, outside air heating/cooling glycol coils, solar heating systems. FEATURES and BENEFITS ■ 65 litre (17 US gallon) tankfor storage and mixing ■ Power supply plugs into any standard 115 VAC outlet E Diaphragm pump can run dry without damage ■ No direct connection to potable water supply eliminates need for backflow prevention ■ Make-up fluid stored in the feeder tank can be pre-treated ■ Diverter valve allows easy purging of air on initial start-up, and manual agitation of solution ■ Prevents major floods- in the event of system rupture, only the contents of the tank will be pumped into the system ■ Provides leak detection-dropping fluid level provides immediate notice that the system has developed a leak ■ Fluid drained for service can easily be put back into the system ■ Fluid level switch shuts the pump off if the storage tank level gets too low ■ Auxiliary dry contact included for remote low pressure alarm (alarm optional or by others) Represented By: AXIOM INDUSTRIES LIMITED 2615 WENTZ AVENUE SASKATOON,SK S7K 5J1 TOLL FREE:(877)651-1815 PHONE:(306)651-1815 FAX:(306)242-3373 1 1 1 INDUSTRIES S L 11117T1r l) MF300 HYDRONIC SYSTEM FEEDER TECHNICAL INFORMATION WEIGHT- 6.8 kg,15 lbs. to Mini-Feed ELECTRICAL r..... Fused Power supply adapter ---------- 115/60/1 to 24 VDC 38 in Rated 50 watts AC 800 mm LED Power Light 32 in 800 mm PUMP PERFORMANCE 0.04 1/s(0.7 gpm)@ free flow Self-priming up to 1.2 m (4 feet) _ 11.751n �i 300 mm -I SPECIFICATION Depth in 300 mm Clearancesnces-Sides and Top-121n 305 mm Discharge 112"FPT Hydronic system feeder shall be AXIOM INDUSTRIES LTD. Model MF300. System shall include 65 litre (17 U.S. gallon)storage/mixing tank with molded-in level gauge, 125 mm (5")fill/access opening and cover; pump suction hose with inlet strainer and check valve; pressure pump with fuse protection; low fluid level pump cut-out float switch; manual diverter valve for purging air and agitating contents of storage tank; pressure switch with snubber and two sets of SPST dry contacts, each individually adjustable from 70 kPa (10 psig)to 170 kPa(25 psig) cut-out pressure; factory cut-out pressure set to 104 kPa (15psig); and liquid filled pressure gauge. Unit to be c/w fused power supply adapter with LED power indicator light, 115/60/1 to 24 VDC 50 watts AC, supplied loose for field installation. Feeder shall be compatible with glycol solutions of up to 50%concentration. Pump shall be capable of running dry without damage. The second set of contacts in the pressure switch shall be wired to a terminal strip for use as low pressure alarm contacts for remote alarm circuit supplied by others.Unit shall be completely assembled. ACCESSORIES ❑ RIA10-I-SAA—Low Pressure Alarm Panel c/w Remote Monitoring Dry Contacts and Selectable Audible Alarm LIMITED WARRANTY The MF300 is warranted against defects in materials and workmanship for one year. Project _ Location Consultant _ Contractor Unit Tag _ _ _�_ Sales Agent / INDUSTRIES LTD. MODEL MF300 `PRESSURE PAL'MINI SYSTEM FEEDER 0 The `PRESSURE PAL' is ideal for feeding and pressurizing closed hydronic systems that do not require cold static fill pressures higher than 170 kPa (25 psig). It is compatible with both water and glycol/water solutions. Perfect for small boiler/chiller systems, snow/ice melt circuits, outside air heating/cooling glycol coils, solar heating systems. FEATURES and BENEFITS ■ 65 litre (17 US gallon) tank for storage and mixing ■ Power supply plugs into any standard 115 VAC outlet ■ Diaphragm pump can run dry without damage ■ No direct connection to potable water supply eliminates need for backflow prevention ■ Make-up fluid stored in the feeder tank can be pre-treated ■ Diverter valve allows easy purging of air on initial start-up, and manual agitation of solution ■ Prevents major floods - in the event of system rupture, only the contents of the tank will be pumped into the system ■ Provides leak detection-dropping fluid level provides immediate notice that the system has developed a leak ■ Fluid drained for service can easily be put back into the system ■ Fluid level switch shuts the pump off if the storage tank level gets too low ■ Auxiliary dry contact included for remote low pressure alarm (alarm optional or by others) Represented By: AXIOM INDUSTRIES LIMITED 2615 WENTZ AVENUE SASKATOON,SK S7K 5J1 TOLL FREE:(877)651-1815 PHONE:(306)651-1815 FAX:(306)242-3373 1 � 1 INDUSTRIES LIMITED MF300 HYDRONIC SYSTEM FEEDER TECHNICAL INFORMATION WEIGHT- 6.8 kg,15 lbs. - i Mint•Fasd ELECTRICAL ............. . ----- Fused Power supply adapter 115/60/1 to 24 VDC 36 in Rated 50 watts AC 900 mm LED Power Light 32 in 800 mm PUMP PERFORMANCE 0.04 1/s(0.7 gpm) @ free flow Self-priming up to 1.2 m(4 feet) L�_ -11.75In I 300 mm I SPECIFICATION Depth In 300 mm Clearancesnces-Sides and Top-12 in 306 mm Discharge 112"FPT Hydronic system feeder shall be AXIOM INDUSTRIES LTD. Model MF300. System shall include 65 litre (17 U.S. gallon)storage/mixing tank with molded-in level gauge, 125 mm (5")fill/access opening and cover; pump suction hose with inlet strainer and check valve; pressure pump with fuse protection; low fluid level pump cut-out float switch; manual diverter valve for purging air and agitating contents of storage tank; pressure switch with snubber and two sets of SPST dry contacts, each individually adjustable from 70 kPa (10 psig)to 170 kPa (25 psig)cut-out pressure; factory cut-out pressure set to 104 kPa(15psig); and liquid filled pressure gauge. Unit to be c/w fused power supply adapter with LED power indicator light, 115/60/1 to 24 VDC 50 watts AC, supplied loose for field installation. Feeder shall be compatible with glycol solutions of up to 50%concentration. Pump shall be capable of running dry without damage. The second set of contacts in the pressure switch shall be wired to a terminal strip for use as low pressure alarm contacts for remote alarm circuit supplied by others.Unit shall be completely assembled. ACCESSORIES ❑ RIA10-1-SAA-Low Pressure Alarm Panel c/w Remote Monitoring Dry Contacts and Selectable Audible Alarm LIMITED WARRANTY The MF300 is warranted against defects in materials and workmanship for one year. Project Location Consultant Contractor Unit Tag . Sales Agent Northwest Plumbing Contractors,Inc. 8/21/19 3810 166"' PL NE#123 Arlington, WA 98223 For: SHARP DESIGN&BUILD LLC 360-653-7224/509-665-3631 NORTHPCO55KB We propose to furnish all materials and labor including the following fixtures and valves necessary to complete the plumbing for: Bid #: 591-06 Name/Address: ROYAL STORAGE SMOKEY POINT NO I FIXTURE DESCRIPTION VALVE/FAUCET I FIXTURE COLOR 1 TOILETS: KOHLER K-96057-0/SLOAN 3250400 FLUSH. TOILET W/OPEN FRONT SEAT WHITE I ** GERBER MAXWELL EB W/WOOD SEAT WHITE 1 LAVS: KOHLER K-2005-0 WALL MT MOEN L4621 CHROME WHITE 1 ** KOHLER K-2005-0 WALL MT SLOAN 3335061 CHROME WHITE TUBS: SHOWERS: 1 KIT.SINK: ELKAY DSE3322 DELTA 300 CHROME SRS 1 MOP SINK: MUSTEE 63M MUSTEE 63.600A CHROME WHITE DISPOSAL: DISHWASHER: install owners with hot water supply and drain ICE MAKER BOX WITH VALVE: with hammer arrestor BAR SINKS: CLOTHES WASHER HOOK-UP: LAUNDRY TRAY: 1 WATER HEATERS: RHEEM PROE6-I-RH-POU ELECTRIC 1 PRESSURE REDUCER 1 KEYSTOP FROST FREE HOSEBIB 2 FLOOR DRAINS: IN MAIN OFFICE BATHROOM/MOP SINK AREA 2 FLOOR DRAINS: FOR BOILERS IN STORAGE AREA (CONNECTED TO STORM BY OTHERS) REMARKS: Does not include sales tax. Does not include any permits. Drains and vents to be ABS. Water service in ditch by others. All trenching and back-fill by others. All pipe insulation by others. *NOT INCLUDED: +$100 PER FIXTURE FURNISHED BY OTHERS FOR INSTALL COST* ACCEPT PROPOSAL (initials) for the sum of- Conditions of sale: All past due accounts subject to 1.5% monthly service charge. Buyer agrees to pay all costs of collection of past due amounts. Northwest Plumbing Contractors,Inc. 8/21/19 3810 1661h PL NE#123 Arlington, WA 98223 For: SHARP DESIGN&BUILD LLC 360-653-7224/509-665-3631 NORTHPCO55KB We propose to furnish all materials and labor including the following fixtures and valves necessary to complete the plumbing for: Bid #: 591-06 Name/Address: ROYAL STORAGE SMOKEY POINT NO I FIXTURE DESCRIPTION VALVE/FAUCET I FIXTURE COLOR 1 TOILETS: KOHLER K-96057-0/SLOAN 3250400 FLUSH. TOILET W/OPEN FRONT SEAT WHITE 1 ** GERBER MAXWELL EB W/WOOD SEAT WHITE 1 LAVS: KOHLER K-2005-0 WALL MT MOEN L4621 CHROME WHITE 1 ** KOHLER K-2005-0 WALL MT SLOAN 3335061 CHROME WHITE TUBS: SHOWERS: 1 KIT.SINK: ELKAY DSE3322 DELTA 300 CHROME SRS 1 MOP SINK: MUSTEE 63M MUSTEE 63.600A CHROME WHITE DISPOSAL: DISHWASHER: install owners with hot water supply and drain ICE MAKER BOX WITH VALVE: with hammer arrestor BAR SINKS: CLOTHES WASHER HOOK-UP: LAUNDRY TRAY: 1 WATER HEATERS: RHEEM PROE6-I-RH-POU ELECTRIC 1 PRESSURE REDUCER 1 KEYSTOP FROST FREE HOSEBIB 2 FLOOR DRAINS: IN MAIN OFFICE BATHROOM/MOP SINK AREA 2 FLOOR DRAINS: FOR BOILERS IN STORAGE AREA(CONNECTED TO STORM BY OTHERS) REMARKS: Does not include sales tax. Does not include any permits. Drains and vents to be ABS. Water service in ditch by others. All trenching and back-fill by others. All pipe insulation by others. *NOT INCLUDED: +$100 PER FIXTURE FURNISHED BY OTHERS FOR INSTALL COST* ACCEPT PROPOSAL (initials) for the sum of: Conditions of sale: All past due accounts subject to 1.5% monthly service charge. Buyer agrees to pay all costs of collection of past due amounts. w AsTE r ♦ h S 'SN" 3� Gd ATh►�vo•� Sol T-0 pM �Q govo ob%i. 3 i' 3� F W A TE OC a W{vdv �ntae� s�•►-r o�t Yy `a StN� r r i )2Scoc>t v Y ' ON- r-Q rr :c •-�RA4 � '/s �r tfol R� Fit n Rc.� G\aSLT `.� �s ra s.s V T 1 asT yJ C LAV — Yi P-CSTIN Xb 3_/►t Co Received `A- SEP 12 2019 S t N�C Figs T' F't can.L r CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:17011 59th Avenue NE,Bldg A Permit#:2789 Parcel#:31052700100900 Valuation: 10000.00 OWNER APPLICANT CONTRACTOR Name:PREMIER PACIFIC PROPERTIES LLC Name:Troy Van Kopp Name:The Janes Company,Inc Address: 13600 44TH ST NE Address:13600 44th Street NE Address:8227 44th Ave W,Ste J City,State Zip:LAKE STEVENS,WA 98258 City,State Zip:Lake Stevens,WA 98258 City,State Zip:Mukilteo,WA 98275 Phone: Phone:425-760-8689 Phone:425-267-0202 LIC:JANESCI079D2 EXP: 12/15/2019 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name:The Janes Company Inc Address: Address:8227 44th Ave W.Ste J City,State,Zip: City,State,Zip:Mukilteo,WA Phone: Phone:4252570202 LIC#: EXP: LIC#:JANESCI079D2 EXP: 12/15/2019 JOB DESCRIPTION PERMIT TYPE: Commercial Plumbing CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1 IO/IRCI10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By Dat CONDITIONS Adhere to approved plans. Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/02/2019 Plumbing Permit Base Fee $25.00 10/02/2019 Plumbing Permit Fee(Enter Fixture Fee) $132.00 10/02/2019 Processing/Technology Fee $25.00 10/02/2019 Plumbing Plan Review Fees $250.00 10/02/2019 Boiler/Compressor $25.00 10/02/2019 Water Heater $25.00 Total Due: $482.00 Total Payment: $0.00 Balance Due: $482.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 2789 Permit Date: 09/13/19 Permit Type: COMMERCIAL PLUMBING Project Name: Royal Storage Applicant Name: Troy Van Kopp Applicant Address: 13600 44th Street NE Applicant, City, State, Zip: Lake Stevens, WA 98258 Contact: Troy Van Kopp Phone: 425-760-8689 Email: troy@sharpdesignbuild.com Scope of Work: Plumbing for office of storage unit facility Valuation: 10000.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 05/04/2020 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning Section 27 Township 31 Range 05 Quarter NE1/4- PAR 2 OF BLA REC AFN 200108315002 EXC TH PTN OF SD PAR 2 LY N 31052700100800 17011 59th Avenue NE OF S LN OF PAR 1 OF SD PREMIER PACIFIC 910 Undeveloped BLA PROJ ELY TO E LN PROPERTIES LLC (Vacant)Land OF SD PAR 2&EXC RDS -AKA PAR 2 OF CITYOF ARL BLA NO Z-06-015- BLA REC AFN 200606055267 Contractors Contractor Primary Contact Phone Address Contractor Type License License# The Janes Company,Inc 425-267-0202 8227 44th Ave W, CONSTRUCTION L&I JANESCI079132 Ste CONTRACTOR Plan Reviews Date Review Type Description Assigned To Review Status 09/13/2019 COMMERCIAL BUILDING PLUMBING 09/13/2019 COMMERCIAL No comments,LT PW-ADMIN-GIS PLUMBING 09/13/2019 COMMERCIAL No comments.SB PW-SEW-REV PLUMBING 09/13/2019 COMMERCIAL PW-WAT-REV PLUMBING Fees Fee Description Notes Amount Plumbing Base Permit Fee $25.00 Mechanical Commercial Permit Table 4-7;Per Unit $132.00 Processing/Technology $25.00 Plumbing Plan Review Fees $250.00 <100>Btu/h>3hp- 15; <500 Btu/hl5-30hp; Boiler/Compressor >1 million Btu/h<50hp; $25.00 >1.5 million Btu/h<50hp; Water Heater(Tank) $25.00 Credit Card Service $14.46 Total $496.46 Attached Letters Date Letter Description 09/27/2019 Building Permit 09/13/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 05/04/2020 TROY VAN KOPP 80151254 $482.00 05/04/2020 80151254 CC Surcharge Raelynn Jones $14.46 Outstanding Balance $0.00 Uploaded Files Date File Name 09/13/2019 5606131-2789 Apnlication.pdf 09/13/2019 5606132-2789 Iso Plans.pdf r CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:17011 59th Avenue NE,Bldg A Permit#:2789 Parcel#:31052700100900 Valuation: 10000.00 OWNER APPLICANT CONTRACTOR Name:PREMIER PACIFIC PROPERTIES LLC Name:Troy Van Kopp Name:The Janes Company,Inc Address: 13600 44TH ST NE Address:13600 44th Street NE Address:8227 44th Ave W,Ste J City,State Zip:LAKE STEVENS,WA 98258 City,State Zip:Lake Stevens,WA 98258 City,State Zip:Mukilteo,WA 98275 Phone: Phone:425-760-8689 Phone:425-267-0202 LIC:JANESCI079D2 EXP: 12/15/2019 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name:The Janes Company Inc Address: Address:8227 44th Ave W.Ste J City,State,Zip: City,State,Zip:Mukilteo,WA Phone: Phone:4252570202 LIC#: EXP: LIC#:JANESCI079D2 EXP: 12/15/2019 JOB DESCRIPTION PERMIT TYPE: Commercial Plumbing CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1 IO/IRCI10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Troy Van Kopp 5/4/2020 p Signature Print Name Date Released By Dat CONDITIONS Adhere to approved plans. Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/02/2019 Plumbing Permit Base Fee $25.00 10/02/2019 Plumbing Permit Fee(Enter Fixture Fee) $132.00 10/02/2019 Processing/Technology Fee $25.00 10/02/2019 Plumbing Plan Review Fees $250.00 10/02/2019 Boiler/Compressor $25.00 10/02/2019 Water Heater $25.00 Total Due: $482.00 Total Payment: $0.00 Balance Due: $482.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon