Loading...
HomeMy WebLinkAbout17309 40th Ave Ne_BLD2787_2026 NOTICE TO PERMITEE AND/OR OWNER PARTIAL APPROVAL O CORRECTIONS REQUIRED ❑ DO NOT OCCUPY ❑ APPROVED PERMIT#: AM PM DATE: /� OB ADDRESS: L_f �� f 1 J /vc LOT#: PROJECT:[ ' TYPE OF INSPECTION: I—. , OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION /ROTC 1`LA!� lttr, {' -i, J r 1 ry t �f d.c .4 4'i'�.�C1 Tlt/l S!!:Jr'uv� r:s.wi4/ iMpi7 j � / f r? THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE 0 PLANNING 0 CIVIL 0 BUILDING CITY OF ARLINGTON „� CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:17309 40th ave ne Permit#:2787 Parcel#:31052100306900 Valuation: 190000.00 OWNER APPLICANT CONTRACTOR Name:AMWA CEDAR POINTE FUND LP Name:[Company Name] Name:AMWA Construction,Inc. Address:30141 AGOURA RD STE 100 Address:[Company Address] Address:30141 Agoura Road,#100 City,State Zip:AGOURA HILLS,CA 91301 City,State Zip:Agoura Hills,WA 91301 City,State Zip:Agoura Hills,CA 91301 Phone: Phone:949-863-9408 Phone:818-706-0694 LIC:AMWACCI824QG EXP: 11/07/2020 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and code City of lington#3101. tM_ Signature *07 Print Name Date Released By Date CONDITIONS 1. Permit and set of approved plans to remain on site during installation. Installers shall present NICET Il certification upon request. 2. Battery load test required, switch system to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3, Trouble condition to be verified for initiation, notification and signaling circuits. 4. Manual pull station shall be dual action. 5. Smoke detectors required in hallway outside of elevator#3 on floors 2 and 3 (not reflected on drawing or battery calcs). 6. Smoke detector required above RPS #3 per NFPA 72 10.44. 7. Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). 8. Record of completion form shall be submitted prior to project close-out. Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the system at project completion. Final approval will not be provided until all conditions are verified. Call at least 48 hours in advance to schedule an inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/28/2019 Fire Alarm Plan Review Fee $100.00 10/28/2019 Fire Permit Fee $2,210.96 10/28/2019 Processing/Technology Fee $25.00 10/28/2019 Credit Card Surcharge $70.08 total Due: 52,406.114 Total Payment: h'_;90(i.04 Balance.Due: 50.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon City of • • yFire Department �l1 NG October 18, 2019 Permit Number: BLD 2787 Project Address: 17309 40th Avenue NE, Arlington Project Description: Fire alarm for Cedar Pointe Apartments Contractor: Mario Turner AMCAL Multihousing Inc. 17862 E 17t" Street, Suite 209 Tustin, CA 92780 Re: Fire Alarm Shop Drawing Review Comments/Approval The Arlington Fire Department has completed a review of the Fire Alarm shop drawing submittal and approves the issuance of the permit with the following conditions: 1. Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request. 2. Battery load test required, switch system to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for initiation, notification and signaling circuits. 4. Manual pull station shall be dual action. 5. Smoke detectors required in hallway outside of elevator#3 on floors 2 and 3 (not reflected on drawing or battery calcs). 6. Smoke detector required above RPS#3 per NFPA 72 10.4.4. 7. Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection (NFPA 72 Section 7.5.2). 8. Record of completion form shall be submitted prior to project close-out. Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the system at project completion. Final approval will not be provided until all conditions are verified. Call at least 48 hours in advance to schedule an inspection. If there are any questions please do not hesitate to call. Sincerely, W". z Mike Makela Assistant Fire Chief Arlington Fire Department OFFICE COPY 6231 :: . 40 :' 1 -� .� ,•:, . • - ' L-A Ll*-,i --r Permit#: 2787 Permit Date: 09/12/19 Project Name: AMCAL Fire Alarm Site Address: 17309 40th ave ne Applicant Name: AMCAL General Contractors Applicant Address: 30141 Agoura Rd Suite 100 City, State,Zip: Agoura Hills, WA 91301 Contact: Mario Turner Phone: 949-863-9408 Email: mario@amcalhousing.com Permit Type: Fire Alarm Valuation: 190000.00 Status: Applied Permit Issued: Permit Expires: Square Feet: 0 Type of Construction/Occupancy Type: Commercial Fire Alarm Number of Stories: 0 Proposed Use: Fire Alarm MIC/Opportunity Zone: Status: IN PROCESS Property C 1 t- Parcel# Address Legal Description Owner Name CITY OF ARL BSP#418 �uJ 31052100306900 17309 40TH AVENUE NE REC AFN 201808215006& AMWA CEDAR AMD BSP REC AFN POINTE FUND LP Exemption Residual 201811065001 Contractors Contractor Primary Contact Phone Address Contractor Type License License AMCAL General Mario Turner 949-863-9408 30141 Agoura Rd CONTRACTOR Contractors Suite 100 1 Plan Reviews Date Review Type Description Assigned To Review Status 09/12/2019 Fire Alarm Building Iti Review 09/12/2019 Fire Alarm Fire In Reviely Fees Fee Description Notes Amount Fire Alarm Plan Review Fee 345.83.00.00 $100.00 Fire Permit Fee 322.10.00.00 $2,210.96 Processing/Technology Fee 341.43.00.02 $25.00 Total $2,335.96 t °� FIRE ALARM PERMIT APPLICATION Department of Community&Economic Development City of Arlington• 18204 59th Ave NE•WA 98223• Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO,INCLUDE SPECIFICATION SHEETS,WIRING DIAGRAMS,(POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) New Fire Alarm Fire Alarm Alteration/Addition 17309 40th ave NE Project Address: * P�cel ID#: 1 205945 190000 Number of Zones/Panels: Building Area(Sq Ft): Valuation: Owner: AMCAL MULTIHOUSING INC _Phone Number: * 949-863-9408 Address: 17862 E 17TH ST STE 209 * City: TUSTIN State: CA * Zip Code: 92780 Contact Person: MARIO TURNER *Phone Number: 949-863-9408 Cell Phone: N/A Email: * MAR10@AMCALHOUSING.COM N/A N/A N/A N/A Address: City: State: Zip Code: Contractor: AMCAL GENERAL CONTRACTORS Phone Number: 818-706-0694 30141 AGOURA RD STE 100 * AGOURA HILLS CA * 91301-4332 Address: City: State: Zip Code: N/A N/A Contractor's License Number: Expiration: Contact Person: MIKE WINTER Email: MWINTER@AMCAL1jOUaINQ,CQlM APPLIED BUSINESS COMMUNICATIONS 253-335-8551 Electrical Contractor: Phone Number* 13029 NE 126TH PL KIRKLAND WA 98034 Address: City: State: Zip Code: Contractor's License Number: APPLIBC843CS Expiration: 02/05/2020 hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws,rules and regulations of the State of Washington. [7cd, r%?o�.re�t 09/11/2019 ApplicaRl'Signature Date Kris Conner Print Applicants Name FOR STAFF USE ONLY R e ce i v e 21 SEP 12 Z019 Permit# A ep Amount Received Receipt# Date Received WEB Form—130 Page 1 of 1 6/16LP l I � R. Qi M Industries Safety&Health IS Claims&Insurance Workplace Rights v Trades Washington State Department of "Labor & Industries Applied Business Comm AZ LLC Owner or tradesperson 213 OLD HIGHWAY 8 SW Principals NEW BRIGHTON,MN 55112 Karel,John J,PARTNER/MEMBER 651-643-6595 Valentine,Matthew J,PARTNER/MEMBER National Registered Agents Inc,AGENT Doing business as Applied Business Comm AZ LLC WA UBI No. Business type 603138 677 Limited Liability Company Governing persons JOHN KAREL MATTHEW JAMES VALENTINE; Certifications & Endorsements License i Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. APPLIBC843CS Effective—expiration 02/05/2016—02/05/2020 Designated administrator Active. Karel,Lawrence R Meets current requirements. License type License no. Electrical Administrator KARELLR854O9 Bond Western Surety Co $4,000.00 Bond account no. 929531846 Received by L&I Effective date 03/09/2012 08/29/2011 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. _ License Violations No license violations during the previous 6 period. Workers' comp Public Works Requirements Workplace safety and health Ir Ington improveHelp us SYSTEM �� SENSOR Selectable-Output Low Frequency Sounder and Low _ Frequency Sounder ► i Strobes for Wall - E _. RE Applications SpectrAlert°Advance audible visible notification products SPECTFi9�lert are rich with features guaranteed to cut installation times and maximize profits. Features The SpectrAlert Advance series offers the most versatile • 520 Hz t 10%square wave tone and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry.With white and red plastic housings, • Plug-in design with minimal intrusion into the back box dual listed for wall and ceiling mounting,SpectrAlert Advance can • Tamper-resistant construction meet virtually any application requirement. • Field-selectable candela settings on wall units: The wall-mount low frequency sounder,and low frequency sounder 135, 150,177,and 185 strobes were designed to address the NFPA 72 sleeping space • Rotary switch for low frequency sounder tone requirements that require a low frequency notification appliance that • Universal mounting plate for wall units operates within frequency range of 520 Hz t 10%and is of a square • Mounting plate shorting spring checks wiring continuity before wave tone.Like the entire SpectrAlert Advance product line they device installation include a variety of features that increase their application versatility while simplifying installation.All devices feature plug-in designs • Electrically compatible with legacy SpectrAlert devices with minimal intrusion into the back box,making installations fast • Compatible with MDL3 sync module and foolproof while virtually eliminating costly and time-consuming • List +mn 11 Ij•� ground faults. CITYOF ARLINGTON To further simplify installation and protect devices from construction BUILDING DEPARTMENT damage.SpectrAlert Advance utilizes a universal mounting plate APPROVEDwith an onboard shorting spring,so installers can test wiring continuity before the device is installed. DATE BY Installers can also easily adapt devices to a suit a wide range of NO CHANGES AUTHORIZED application requirements using field-selectable candela settings, Age4cy Lisft S APPROVED BY THE automatic selection of 12-or 24-volt operation,and a rotary switch for 520 Hz low frequency sounder tones. SIGNALING &L F M MEA LISTED •ppwaa approved 1 54011(sauntler) 3047563 MEA452d1_'-E 7135,1653:0223 COPY S5512(strobes) 7125-1fi,53022 OFFICE 4 D r':1,T).A'4Q Y'TID Tv L2,11VGA99A SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11/2-Inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the SynceCircuit"'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the SynceCircuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Low Frequency Sounder strobes shall have field-selectable candela settings including 135, 150, 177, and 185.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone and have a permanent marking on the housing that reads"low frequency sounder". Low Frequency Sounder The low frequency sounder shall be a System Sensor SpectrAlert Advance Model listed to UL 464 and shall be approved for fire protective service.The low frequency sounder and the SynceCircuitTM MDL3 Module accessory,if used,shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts(includes fire alarm panels with built in sync).When used with the SynceCircuit Module MDL3, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts.If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used,then refer to the compatibility listing of the panel to determine maximum devices on a circuit.The low frequency sounder has an option to switch between temporal three pattern,non-temporal(continuous)pattern and coded supply within the frequency range of 520Hz t 10%square wave tone.The low frequency sounder shall operate on a coded or non-coded power supply. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The sounder shall have an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply.The field selectable tones will sound within the frequency range of 520 Hz t10%square wave tone. Synchronization Module The module shall be a System Sensor SynceCircuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three.Also,while operating the strobes,the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Frequency Range 520 Hz t 10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 12 DCJFWR or regulated 24 DC/FWR1 Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 6.4 inches L x 4.7 inches W x 2.5 inches D (162 mm L x 119 mm W x 64 mm D) Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 inches D (142mmLx 119 mm W x 33 mm D) Low Frequency Sounder/Strobe with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D Dimensions(SBBR,SBBW) (162 mm L x 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D (SBBR,SBBW) (145 mm L x 120 mm W x 76 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. I I ;u UL Current Draw Data UL Max.Low Frequency Sounder Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 191 262 138 166 Continuous Hiah 292 384 138 208 Coded High 292 388 153 205 SounderUL Max.Current Draw(mA RMS),2-Wire Low Frequency .. 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal 277 292 325 344 Temporal 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 Low Frequency Sounder Tones and Sound Output Data StrobeLow Frequency Sounder and Low Frequency Sounder • .: 8-17.5 16-33 24-Volt Nominal Volts Volts Reverberant Anechoic Switch Position Sound Pattern DC FWR DC FWR DC FWR DC FWR i Temporal 76 76 76 76 76 76 86 86 2 Continuous 80 80 80 80 80 80 90 90 3t Coded 80 80 80 80 80 80 90 90 t Sounder ratings provided are for continuous voltage as provided by the NAC i SpectrAlert Advance Dimensions 4.7 in.� — 2.5 in. 10 4.7 in. 1.3 in. l 00/OT PIJR Q� d� dot III IL�t 6.4 In. ® 5.6 in. c� o 0 Wall-mount low frequency sounder strobes Wall-mount low frequency sounder SpectrAlert Advance Ordering Information Model Description Wall Low Freguency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe,High cd,Red P2WH-LF 2-Wire Low Frequency Sounder Strobe,High cd,White Low Frequency Sounders HR-LF Low Frequency Sounder,Red HW-LF Low Frequency Sounder,White Accessories SBBR Surface Mount Back Box,Wall,Red SBBW Surface Mount Back Box,Wall,White TR-HS Trim Ring,Wall,Red Notes: "High cd"refers to strobes that include 135,150,177,and 185 candela settings. SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 @015syst� se sot. 1 Phone:800-SENSOR2•Fax:630-377-6495 Product sperlrea abpat to UwW without nooc Vm systeywtsa.corr, A/�/7(,//1Q for current lYoCW Ha laG�i,irck dng the taiest w§on of this data sheet. -SENSORwww.systemsensor.com AVDS16404.1115 i SYSTEM SENSOR' Indoor Selectable- Output Horns,Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cutJr., installation times and maximize profits with lower current draw and modern aesthetics. Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red plastic housings,standard and compact devices,and plain, FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns,strobes,and horn strobes 15,30,75,95, 110,135,and 185 include a variety of features that increase their application versatility • Horn rated at 88+dBA at 16 volts while simplifying installation.All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage,the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING U� ANROVlO LIM S5512 FM approved except 7125-1653 W S4011 for Ai ERT maels 71351S530503 3057383,3057072 AVDS66505•222I2019•Page 1 I 1 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/6-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltaqe Regulated 12 DC or regulated 24 DC/FWR7 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 1.91-D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including_lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.25-D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AN]5865-05-W212018•Page 2 i UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal Hiah 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 CandelaUL Max.Current Draw(mA RMS),Wall Horn Strobe,8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1 K Non-Temporal High 104 131 177 204 230 264 326 3.1 K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data StrobeHorn and Horn • .: 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 64 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9` Coded High 85 90 90 10' 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVDS8&-A5.21226M•Page 3 � ��� .. i L-Series Dimensions 485 3.46 3.46" mm BB mm ••'} — AST i9C• 99 mm — 1.2 1.25" 32 32 mm (9.1 CM) (3.9 cm) 32 mm O 5.2)- 1 5.39" 133.9 mm . S S.2T ,a.. (13.7 cm)LC O tAi8ne1 Y Ih1�IM O 0 � I A0546-00 A0547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL (11.94 cm) 1.91" 4.7" (4.95 cm) 119 mm 1,25• 1 , I I 32 mm (12.24.24c cm) 1.25" I I (4.69 cm) (3.16 mm) E O 5.67• (14.4 cm) 144 mm '14.SScm) 111141 10 * f A0554-01 Strobe,Horn Strobe A0550-00 Horn Ao549-0o Wall Surface Mount Back Box SBBRUSBBWL L-Series Ordering Information DescriptionModel Description Model Wall Horn Strobes Horns* P2RL 2-Wire,Horn Strobe,Red HRL* Horn,Red P2WL 2-Wire,Horn Strobe,White HWL' Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL* Compact Horn,Red P2GWL 2-Wire,Comp 2 fils act Horn Strobe,White HGWL* Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White.FUEGO SBBRL Wall Surface Mount Back Box,Red P4RL 4-Wire,Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe,White SBBGRL Compact Wall Surface Mount Back Box,Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe,Red SWL Strobe,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover). All-SP models have"FUEGO"marking on cover. All-ALERT models have"ALERT"marking on cover. *Horn-only models are listed for wall or ceiling use. SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 �,120,6 SYs'•em Sensor. Phone:800-SENSOR2•Fax:63G-377-6495 Prcdt t SPer7rk:3ws slA) I to atvge mqw nJA1 vst SySlerRSP ..Cam SEAIS'OR www.systemsensor.com `�G"&`°� "Avow 5 zn`rzo1e'`°'a"` �' ` SYSTEM SENSOR" Indoor Selectable- Output Strobes and Horn Strobes for ===- Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut Mile installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING U� Avanoveo LWED FM approwd except 712'.r1653 W for AL ERT rr odels 7135-1663OM 30573M AVDS86&02•12A1y2017•Page 3 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1Y2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit' Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 21i8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating_Temperature 32°F to 120'F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR' Operating Voltage Ranae2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltaqe Ranqe(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) InputTenninal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02.12M172017•Page 2 i UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal Hiah 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal Hiah 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded Hiah 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal Hiqh 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal Hiah 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal Hiqh 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal Hiqh 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal Hiah 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal Hiah 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS86&02.12101rG17•Page 3 L-Series Dimensions 2.47"(62.7 mm) 1.37"(34.8 mm) 6.92"diam. _ 231 �{ 6.83°diam. (175.77 mm) (64 mm) (173 mm) eu run CD 0 0 ® o 0 0 0 0 0 --- A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box O ° � O ® ° o 0 0 A0494-01 A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe.White SCWL Strobe,White PC4RL 4-Wire.Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". SYSTEM 02017 Sys tern.Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Fri,cts�;1�u«�s,b;�lrc�geWh":rl�e.u��systernsensucccm SENSOR Phone:BOO-SENSOR2•Fax:630-377-6495 For currentpoductiebrmation,ancludg the Latest wsond this data sheet. AVDSM-02•12MIR017 Job Name: Smokey Point Senior Living Job# WA190008 Prepared By: Kristopher Conner,SET Date: 9/9/2019 FACP Battery Calculations Standby Current(amps) Secondary Alarm Current(amps) Qty Current Draw -L T661 Qty I Current Draw 1.Control Panel&Power Supplies 6820 1 x 0.190000 = 0.190000 1 x 0.250000 = 0250000 PS106 16 x 0.000000 = 0000000 16 x 0.000000 = 0000000 x = x = x = x = 2.Addressable SLC Devices SK-Photo-W 56 x 0.002000 = 0112000 56 xj 0.004500 = 0.252000 SK-Heat-W 4 x 0.002000 = 0.008000 4 x 0.004500 = 0018000 'SK-MINIMON 52 x 0.003500 = 0182000 52 x 0.003500 = 0 182000 i SK-Relay 48 x 0.002500 = 0 120000 48 x 0.002500 = 0.120000 ,/SK-PuIISA 1 x 0.003500 = 0003500 1 x 0.003500 = 0.003500 SK-Monitor 3 x 0.003500 = 0010500 3 x 0.003500 = 0.010500 Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = 3.SLC Accessory Bases Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = X1 0.000000 = Unused x 0.000000 = X1 0.000000 - 4.SLC Isolator Devices Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x I 0.000000 - Unused x 0.000000 = x 1 0.000000 - 5.Auxiliary Power Draw-SLC Devices Unused x 0.000000 1XI 0.000000 = Unused x 0.000000 = 1XI 0.000000 I= Unused x 0.000000 1XI 0.000000 I= 6.Accessory Modules Unused x 0.000000 = x 0.000000 - Unused x 0.000000 1XI 0.000000 = Unused I x 0.000000 1XI 0.000000 1= 7.Voice Amplifiers and Accessories Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = 8.Miscellaneous Devices Unused x 0.000000 = X1 0.000000 = Unused x 0.000000 = X1 0.000000 = Unused x 0.000000 = X1 0.000000 = 9. Output Circuits NAC 1 1 x 0.000000 = 0.000000 1 xj 1 013000 = 1 013000 NAC 2 1 x 0.000000 = 0.000000 1 x 0470000 = 0470000 NAC 3 1 x 0000000 = 0000000 1 x 0.613000 = 0.613000 NAC 4 1 x 0000000 = 0000000 1 x 0111000 = 0111000 NAC 5 1 x 0.000000 = 0000000 1 x 0000000 = 0000000 NAC 6 1 x 0000000 = 0.000000 1 x 0.000000 = 0.000000 0.626000 Total Alarm Load 3.043000 DATE 6 NO CHA NGES A- OFFICE COPY U1H0RI UNLESS APPROVED BY THE BUILDING INSPECTOR r. Y Calculation in Total Sheet . . 24 Hours Standby Load Current 0.62600 Amps x 24 - 15.024 AH Required Alarm Time in Minutes 5 Minutes Alarm Load Current(Amps) 3.04300 Amps x F 0.084 1= 0.256 AH Total Current Load 15.280 AH Multiply by the Derating Factor 1.2 = x 1.20 Total Ampere Hours Required 18.34 AH Recommended Batteries: r ABOOM Circuit Detail NAC 1 Device Qty Non-Alarm . . ()ty I Alarm Draw Total PC2L Ceiling Horn/Strobe 175-:d 1 x 0.000000 = 0000000 1 x 0.147000 = 0.147000 ✓ PC2L Ceiling Horn/Strobe(30 cc 1 x 0.000000 = 0.000000 1 x 0.094000 = 0.094000 ✓ PC2L Ceiling Horn/Strobe(15 cc 2 x 0.000000 = 0000000 2 x 0.071000 = 0.142000 ✓ P2L Wall Horn/Strobe(15 cd) 2 x 0.000000 = 0.000000 2 x 0.054000 = 0.108000 V SCL Ceiling Strobe(15 cd) 1 x 0,000000 = 0000000 1 x 0.041000 = 0.041000 ✓ SL Wall Strobe(75cd) 1 x 0.000000 = 0.000000 1 x 0.111000 = 0111000 ✓ P2L Wall Horn/Strobe(110 cd) 2 x 0.000000 = 0,000000 2 x 0.185000 = 0.370000 Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 - Total Standby Load 0.000000 Total Alarm Load 1.013000 NAC 2 Device e Draw Total Qty Alarm Draw Total SL Wall Strobe (15cd) 3 x 0.000000 0.000000 0.000000 3 xUO400^ = 0 123000 ,1aq P2L Wall Horn/Strobe(30 cd) 1 x 0.000000 0.000000 0.000000 1 x00 = 0.071000 .DILJ PC2L Ceiling Horn/Strobe(15 cc 1 x 0.000000 0.000000 0,000000 1 x00 = 0.071000 fPC2L Ceiling Horn/Strobe(30 cc 1 x 0.000000 0.000000 0.000000 1 x00 = 0.094000 ✓ SCL Ceilinq Strobe(75 cd) 1 x 0.000000 0.000000 0.000000 1 x 0.111000 = 0.111000 ✓ Unused x 0.000000 0.000000 x 0.000000 = Unused x 0.000000 0.000000 x 0.000000 = Unused x 0.000000 0.000000 x 0.000000 = Unused x 0.000000 0.000000 x 0.000000 - Unused x 0.000000 0.000000 x 0.000000 J= Total Standby Load 0.000000 Total Alarm Load o.470000 „n-11 NAC 3 Device • Draw Tota I Qty I Alarm Draw Total PC2L Ceiling Horn/Strobe (15 cc 3 x 0.000000 = 0.000000 /5 > x 0.071000 = 0.355000 SCL Ceiling Strobe(15 cd) 4 x 0.000000 = 0.000000 4 x 0.041000 = 0164000 PC2L Ceiling Horn/Strobe(30 cci 1 x 0.000000 = 0.000000 1 x 0.094000 = 0094000 ✓ Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 - Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Total Standby Load 0.000000 Total Alarm Load 0.613000 .. 4- i%� NAC 4 Total32 Qty Non-Alarm Draw Total Qty I Alarm Draw P2RK Outdoor Wall Horn Strobe 1 x 0.000000 = 0000000 1 x 0.111000 = 0.111000 Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Total Standby Load 0.000000 Total Alarm Load o.111000 NAC 5 Device Qty Non-Alarm Draw Tota I Qty Alarm Draw Total Unused x 0.000000 = x 0.000000 - Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 - Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = XI 0,000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 1 0.000000 = x 0.000000 - Total Standby Load 0.000000 Total Alarm Load 0.000000 NAC 6 Device Qty Non-Alarm Draw Total aty Alarm Draw Total Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 - Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 = x 0.000000 = Unused x 0.000000 1 x 0.000000 - Total Standby Load 0.000000 Total Alarm Load 0.000000 Global Project Values: Project Name: Smokey Point Senior Livinq Standby Hours: 24 A6�OM Project I : WA189008 Alarm t :� Prepared By: Kristo her Conner,SET Derating Factor: 1.2 Date: 8/19/2019 Voltage Drop Warning Threshold%: 15 Panel ID: IRPS#1 Model: PSN106 Max NAC Current: 3.0 Amps Location: JElectrical Room by Unit 154 Volts: 24 VDC Max Panel Current: 10.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ a Ckt.# Circuit Name Standbv Alarm &Tvoe 1000 Ft. One-Wav Ohms EOL �oDrop BPS10A PSN106 1 0.060 0.200 NAC#1 NAC#5-1 st floor 0.000 0.966 #14 Solid 2.52 150 0.76 19.67 3.58% NAC#2 NAC#6- 1 st floor 0.000 1.656 #14 Solid 2.52 250 1.26 18.31 10.23% NAC#3 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% NAC#4 0.000 0.000 #14 Solid 2.52 0.00 20.40 1 0.00% Aux 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Total Standbv Current(AmDS)i 0.060 2.822 Total Alarm Current(AmDS) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 (5 Mins) Total Standby AH Reauiredl 1.440 0.235 Total Alarm AH Required Total Combined AH Reauiredl 1.68 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmDHours Reouired 270171 Configure Circuits I Print Page Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA189008 Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt. Number: NAC 5-1 st floor Panel ID: RPS#1 Ckt. Name: 1 st floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standbv Alarm 7 HW-LF 0.000 0.138 0.000 0.966 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 1 0.000 Totals 0.000 1 0.966 Ckt. Number: NAC#2 Panel ID: RPS#1 Ckt. Name: NAC#6-1 st floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 12 HW-LF 0.000 0.138 0.000 1.656 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1 1.656 Ckt. Number: NAC#3 Panel ID: RPS#1 Ckt. Name: 0 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 0.000 Ckt. Number: NAC#4 Panel ID: RPS#1 Ckt.Name: 0 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standbv Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 0.000 r 1 Global Project Values: Project Name:ISmokey Point Senior Livinq Standby Hours: 24 A6 �� Project ID: WA189008 Alarm Mins:� Prepared By: Kristopher Conner, SET Derating Factor: 1 2 Date: 8/19/2019 Voltage Drop Waming Threshold%: 15 Panel ID: I RPS#2 Model: PSN106 Max NAC Current: 3.0 Amps Location: JElectrical Room by Unit 143 Volts: 24 VDC Max Panel Current: 10.0 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm &Type 1000 Ft. One-Way Ohms EOL BPS10A PSN106 1 0.060 0.200 NAC#1 NAC#7- 1st floor 0.000 0.697 #14 Solid 2.52 180 0.91 19.77 3.10% NAC#2 NAC#8- 1st floor 0.000 2.021 #14 Solid 2.52 180 0.91 18.57 8.99% NAC#3 NAC#9- 1 st floor 0.000 1.104 #14 Solid 2.52 180 0.91 19.40 4.91% NAC#4 NAC#10-1 st floor 0.000 2.232 #14 Solid 2.52 180 0.91 18.38 9.93% Aux 0.000 0.000 #12 Solid 1 1.59 1 0,00 20.40 0.00% Total Standby Current(Amps) 0.060 6.254 Total Alarm Current(Amos) Standbv Time In Hours 24 0.083 Alarm Time In Minutes/60 (5 Mins) Total Standby AH Required 1.440 0.521 Total Alarm AH Required Total Combined AH Reoulred 1.96 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery Amr)Hours Required 2.35 Configure Circuits 1 ( Print Page • 7 •ti 1 I Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA189008 Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt. Number: NAC#7-1 st floor Panel ID: RPS#2 Ckt. Name: 1st floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 HW-LF 0.000 0.138 0.000 0.552 1 SCL Ceilinq Strobe(30 cd) 0.000 0.063 0.000 0.063 2 SCL Ceiling Strobe(15 cd) 0.000 0.041 0.000 0.082 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 0.697 Ckt. Number: NAC#8- 1 st floor Panel ID: RPS#2 Ckt. Name: NAC#8-1st floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 HW-LF 0.000 0.138 0.000 0.690 2 SL Wall Strobe(15cd) 0.000 0.041 0.000 0.082 3 P2WH-LF @ 177cd 0.000 0.325 0.000 0.975 2 P21-Wall Horn/Strobe(75 cd) 0.000 0.137 0.000 0.274 0.000 0.000 Totalsl 0.000 1 2.021 Ckt. Number: NAC#9-1 st floor Panel ID: RPS#2 Ckt. Name: NAC#9-1 st floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 8 HW-LF 0.000 0.138 0.000 1.104 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 1 0.000 Totalsl 0.000 1 1.104 Ckt. Number: NAC#10-1st floor Panel ID: RPS#2 Ckt. Name: NAC#10-1st floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 15 HW-LF 0.000 0.138 0.000 2.070 3 P21-Wall Horn/Strobe(15 cd) 0.000 0.054 0.000 0.162 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 2.232 Global Project Values: Project Name:ISmokey Point Senior Living Standby Hours: 24 A6��MTM Project ID: WA189008 Alarm Mins:� Prepared By: Kristopher Conner, SET berating Factor: 1.2 Date: 8/19/2019 Voltage Drop Warning Threshold%: 15 Panel ID: RPS#3 Model: PSN106 Max NAC Current: 3.0 Amps Location: Electrical Room by Unit 143 Volts: 24 VDC Max Panel Current: 10.0 Amps Current Draw Wire AW G Ohms Per Length(ft) Actual Volts @ a Ckt.# Circuit Name Standby Alarm &Type 1000 Ft. One-Way Ohms EOL �oDrop BPS10A PSN106 1 0.060 0.200 NAC#1 NAC#11 - 1 st floor 0.000 0.247 #14 Solid 2.52 200 1.01 20.15 1.22% NAC#2 NAC#12- 1 st floor 0.000 1.656 #14 Solid 2.52 200 1.01 18.73 8.18% NAC#3 NAC#13- 1 st floor 0.000 1.956 #14 Solid 2.52 200 1.01 18.43 9.66% NAC#4 NAC#14-1st floor 0.000 1.380 #14 Solid 2.52 200 1.01 19.01 6.82% Aux 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Total Standby Current(Amps) 0.060 5.439 Total Alarm Current(Amps) Standbv Time In Hours 24 0.083 Alarm Time In Minutes/60 15 Mins) Total Standbv AH Reauired 1.440 T0,453 Total Alarm AH Required Total Combined AH Required 1.89 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiplv By The Deratinq Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Baftery AmpHours Required 2.27 Configure Circuits I I Print Page 1 � r, R I Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA189008 Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt. Number: 11 Panel ID: RPS#3 Ckt. Name: NAC#11 -1 st floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 PC21-Ceiling Horn/Strobe(15 cd) 0.000 0.071 0.000 0.071 1 PC2L Ceilinq Horn/Strobe (30 cd) 0.000 0.094 0.000 0.094 2 SCL Ceilinq Strobe(15 cd) 0.000 0.041 0.000 0.082 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 0.247 Ckt. Number: 12 Panel ID: RPS#3 Ckt. Name: NAC#12- 1st floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standbv Alarm 12 HW-LF 0.000 0.138 0.000 1.656 Unused 0.000 0,000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1 1.656 Ckt. Number: 13 Panel ID: RPS#3 Ckt. Name: NAC#13- 1 st floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 13 HW-LF 0.000 0.138 0.000 1.794 3 P2L Wall Horn/Strobe(15 cd) 0.000 0.054 0.000 0.162 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1.956 Ckt. Number: 14 Panel ID: RPS#3 Ckt. Name: NAC#14-1st floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 10 HW-LF 0.000 0.138 0.000 1.380 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0,000 0.000 0.000 Totals 0.000 1.380 1 ` 1 � . i � - 1 . . . - ter ■-� 1 1 - � i� - - - = ■ . - - - 1 r 7 067 LI 1 J r ' OrL. J 1 "P■ - mmi �J ■ mm - ■ - ■ . . 1 ' 1 IT ' • ' ■ r Z M9 I ) , . e ` 7 LONF.L. MM ' - - ■ ■ ILA - • ! T ■ r1 J A % NL 3RJ2 z 1 ■ ■ - NONE . - - ■ mm `� ■ ■ Global Project Values: Project Name: Smokev Point Senior Living Standby Hours: 24 Pr Project ID: WA190008 Alarm Mins: A-- D]4 � Prepared By: Kristo her Conner,SET Derating Factor: 1.2 Date: 8/19/2019 Voltage Drop Warning Threshold%: 15 Panel ID: IRPS#4 Model: PSN106 Max NAC Current: 3.0 Amps Location: JElectrical Room by Unit 109 Volts: 24 VDC Max Panel Current: 10.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ Ckt.# Circuit Name Standby Alarm &Type 1000 Ft. One-Way Ohms EOL %Drop BPS10A PSN106 1 1 0.075 0.205 NAC#1 NAC#15- 1 st floor 0.000 0.449 #14 Solid 2.52 175 0.88 20.00 1.94% NAC#2 NAC#16- 1st floor 0.000 2.760 #14 Solid 2.52 200 1.01 17.62 13.64% NAC#3 NAC#17- 1 st floor 0.000 2.524 #14 Solid 2.52 225 1.13 17.54 14.03% NAC#4 unused 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% Aux JAux 0.000 0.000 #12 Solid 1 1.59 1 0.00 20.40 0.00% Total Standbv Current(Amos) 0.075 5.938 Total Alarm Current(Amps) Standbv Time In Hours 24 0.083 Alarm Time In Minutes/60 5 Mins Total Standby AH Required 1.800 0.495 Total Alarm AH Required Total Combined AH Required 2.29 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Deratina Factor 1.20 the minimal difference between solid and stranded wire no differential was made_ Minimum Battery AmpHours Required 2.75 Configure Circuits I I Print Page Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA190008 Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt. Number: 15 Panel ID: RPS#4 Ckt. Name: NAC#15- 1st floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 PC2L Ceiling Horn/Strobe(15 cd) 0.000 0.071 0.000 0.142 1 PC21-Ceiling Horn/Strobe (30 cd) 0.000 0.094 0.000 0.094 3 PC2L Ceiling Horn/Strobe (15 cd) 0.000 0.071 0.000 0.213 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 0.449 Ckt. Number: 16 Panel ID: RPS#4 Ckt. Name: NAC#16-1 st floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 20 HW-LF 0.000 1 0.138 0.000 2.760 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1 2.760 Ckt. Number: 17 Panel ID: RPS#4 Ckt. Name: NAC#17- 1 st floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total- Standby Tot71- Standby Alarm Standbv Alarm 11 HW-LF 0.000 0.138 0.000 1.518 2 P21-Wall Horn/Strobe(75 cd) 0.000 0.137 0.000 0.274 2 P2WH-LF @ 177cd 0.000 0.325 0.000 0.650 2 SL Wall Strobe(15cd) 0.000 0.041 0.000 0.082 0.000 0.000 Totals 0.000 2.524 Ckt. Number: Panel ID: RPS#4 Ckt. Name: unused Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standbv Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals! 0.000 1 0.000 Global Project Values: Project Name:JSmokeV Point Senior Living_ Standby Hours: 24 Project ID:I WA190008 Alarm Mins:F A6001 Prepared By:rKristopher Conner,SET Derating Factor: 1.2 Date: 8/19/2019 Voltage Drop Warning Threshold%: 15 Panel ID: IRPS#5 Model: PSN106 Max NAC Current: 3.0 Amps Location: JElectrical Room by Unit 253 Volts: 24 VDC Max Panel Current: 10.0 Amps Current Draw W ire AW G Ohms Per Length(ft) Actual Volts @ Ckt.# Circuit Name Standbv Alarm &TVpe 1000 Ft. One-Wav Ohms EOL %Drop BPS10A PSN106 1 0.060 0.200 NAC#1 NAC#18-2nd floor 0.000 1.104 #14 Solid 2.52 200 1.01 19.29 5.46% NAC#2 NAC#19-2nd floor 0.000 2.346 #14 Solid 2.52 200 1.01 18.04 11.59% NAC#3 NAC#20-2nd floor 0.000 0.410 #14 Solid 2.52 200 1.01 19.99 2.03% NAC#4 NAC#21 -2nd floor 0.000 1.794 #14 Solid 2.52 200 1.01 18.59 8.86% Aux lAux 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Total Standbv Current(Amps) 0.060 5.854 Total Alarm Current Am s Standbv Time In Hours 24 0.083 Alarm Time In Minutes/60 5 Mins Total Standby AH Required 1.440 0.488 Total Alarm AH Required Total Combined AH Required 1.93 Wire resistances are based upon an ambient temperature of 72 degrees F, Because of Multiplv By The Deratino Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.31 Configure Circuits I I Print Page 1 Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA190008 Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt. Number: 18 Panel ID: RPS#5 Ckt. Name: NAC#18-2nd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standbv Alarm Standbv Alarm 8 HW-LF 0.000 0.138 0.000 1.104 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0,000 0.000 0.000 Totals 0.000 1.104 Ckt.Number: 19 Panel ID: RPS#5 Ckt.Name: NAC#19-2nd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standbv Alarm Standbv Alarm 17 HW-LF 0.000 0.138 0.000 2.346 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 2.346 Ckt. Number: 24 Panel ID: RPS#5 Ckt.Name: NAC#20-2nd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standbv Alarm Standbv Alarm 3 SCL Ceilina Strobe 05 cd) 0.000 0.041 0.000 0.123 4 P21-Wall Horn/Strobe(15 cd) 0.000 0.054 0.000 0.216 1 P21-Wall Horn/Strobe(30 cd) 0.000 0.071 0.000 0.071 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.410 Ckt. Number: 25 Panel ID: RPS#5 Ckt.Name: NAC#21 -2nd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standbv Alarm Standbv Alarm 13 HW-LF 0.000 0.138 0.000 1.794 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0,000 0.000 0.000 Totalsl 0.000 1 1.794 Global Project Values: Project Name:ISmokey Point Senior Living Standby Hours:F 24 A130�7V1 Project I y: W A190008 Alarm actor:� Prepared By: Kristopher Conner, SET Derating Factor: 1.2 Date: 8/19/2019 Voltage Drop Warning Threshold%: 15 Panel ID: IRPS#6 Model: PSN106 Max NAC Current: 3.0 Amps Location: JElectrical Room by Unit 244 Volts: 24 VDC Max Panel Current: 10.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ o Ckt.# Circuit Name Standby Alarm &Type 1000 Ft. One-Way Ohms EOL �oDrop BPS10A PSN106 1 0.060 1 0.200 NAC#1 NAC#22-2nd floor 0.000 1.104 #14 Solid 2.52 200 1.01 19.29 5.46% NAC#2 NAC#23-2nd floor 0.000 1.601 #14 Solid 2.52 200 1.01 18.79 7.91% NAC#3 NAC#24-2nd floor 0.000 2.484 #14 Solid 2.52 200 1.01 17.90 12.27% NAC#4 NAC#25-2nd floor 0.000 0.788 1#14 Solid 1 2.52 200 1.01 19.61 3.89% Aux JAux 0.000 0.000 1#12 Solid 1 1.59 0.00 20.40 0.00% Total Standbv Current(Amps) 0.060 6.177 ITotal Alarm Current(Amps) Standbv Time In Hours 24 0.083 Alarm Time In Minutes/60 5 Mins Total Standby AH Required 1.440 0.515 Total Alarm AH Required Total Combined AH Required 1.95 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor, 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.35 Configure Circuits I Print Page Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA190008 Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt.Number: 22 Panel ID: RPS#6 Ckt. Name: NAC#22-2nd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 8 HW-LF 0.000 0.138 0.000 1.104 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1.104 Ckt. Number: 23 Panel ID: RPS#6 Ckt. Name: NAC#23-2nd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 HW-LF 0.000 0.138 0.000 0.690 2 SL Wall Strobe(15cd) 0.000 0.041 0.000 0.082 3 P21-Wall Horn/Strobe(110 cd) 0.000 0.185 0.000 0.555 2 P21-Wall Horn/Strobe(75 cd) 0.000 0.137 0.000 0.274 0.000 0.000 Totalsl 0.000 1 1.601 Ckt. Number: 24 Panel ID: RPS#6 Ckt. Name: NAC#24-2nd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 18 HW-LF 0.000 0.138 0.000 2.484 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 2.484 Ckt. Number: 25 Panel ID: RPS#6 Ckt. Name: NAC#25-2nd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 HW-LF 0.000 0.138 0.000 0.552 2 PC21-Ceiling Horn/Strobe(15 cd) 0.000 0.071 0.000 0.142 1 PC2L Ceiling Horn/Strobe(30 cd) 0.000 0.094 0.000 0.094 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.788 r• � c Global Project Values: Project Name:I Smokev Point Senior Living Standby Hours: 24 AM, �M Project ID: Kristo WA190008 Alarm t : Pr � epared By: oher Conner._SET Derating Factor: 1 2 Date: 8/19/2019 Voltage Drop Warning Threshold%: 15 Panel ID: IRPS#7 Model: PSN106 Max NAC Current: 3.0 Amps Location: JElectrical Room by Unit 220 Volts: 24 VDC Max Panel Current: 10.0 Amps Current Draw Wire AW G Ohms Per Length(ft) Actual Volts @ o Ckt.# Circuit Name Standby Alarm &Type 1000 Ft. One-Way Ohms EOL �aDrop BPS10A PSN106 1 1 0.060 0.200 NAC#1 NAC#26-2nd floor 0.000 0.250 #14 Solid 2.52 200 1.01 20.15 1.24% NAC#2 NAC#27-2nd floor 0.000 2.208 #14 Solid 2.52 200 1.01 18.17 10.91% NAC#3 NAC#28-2nd floor 0.000 1.656 #14 Solid 2.52 200 1.01 18.73 8.18% NAC#4 INAC#29-2nd floor 0.000 1.380 #14 Solid 2.52 200 1.01 19.01 6.82% Aux IAux 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Total Standby Current(Amps) 0.060 5.694 Total Alarm Current(Amps) Standbv Time In Hours 24 0.083 Alarm Time In Minutes/60 5 Mins Total Standbv AH Required 1.440 0.475 Total Alarm AH Required Total Combined AH Required 1.91 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Deratinq Factorl 1.20 the minimal difference between solid and stranded wire no differential was made, Minimum Battery AmpHours Required 2.30 Configure Circuits 1 I Print Page 1 ti i Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA190008 Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt. Number: 26 Panel ID: RPS#7 Ckt. Name: NAC#26-2nd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standbv Alarm Standbv Alarm 1 PC21-Ceilinq Horn/Strobe(15 cd) 0.000 0.071 0.000 0.071 1 PC21-Ceiling Horn/Strobe(15 cd) 0.000 0.071 0.000 0.071 2 P21-Wall Horn/Strobe 05 cd) 0.000 0.054 0.000 0.108 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.250 Ckt. Number: 27 Panel ID: RPS#7 Ckt. Name: NAC#27-2nd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standbv Alarm Standbv Alarm 16 HW-LF 0.000 0.138 0.000 2.208 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 2.208 Ckt. Number: 28 Panel ID: RPS#7 Ckt. Name: NAC#28-2nd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 12 HW-LF 0.000 0.138 0.000 1.656 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1.656 Ckt. Number: 29 Panel ID: RPS#7 Ckt. Name: NAC#29-2nd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 10 HW-LF 0.000 0.138 0.000 1.380 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 1 0.000 Totalsl 0.000 1 1.380 — Global Project Values: Project Name:JSmokeV Point Senior Livinq Standby Hours: 24 Project ID: WA190008 Alarm Mins:� ASO M Prepared By:FKnstopher Conner,SET I Derating Factor: 1.2 Date: 8/19/2019 Voltage Drop Warning Threshold%: 15 Panel ID: IRPS#8 Model: PSN106 Max NAC Current: 3.0 Amps Location: JElectrical Room by Unit 209 Volts: 24 VDC Max Panel Current: 10.0 Amps Current Draw Wire AW G Ohms Per Length(ft) Actual Volts @ o Ckt.# Circuit Name Standbv Alarm &TVoe 1000 Ft. One-Wav Ohms EOL �oDrop BPS10A PSN106 1 1 0.060 0.200 NAC#1 NAC#30-2nd floor 0.000 0.398 #14 Solid 2.52 200 1.01 20.00 1.97% NAC#2 NAC#31 -2nd floor 0.000 2.760 #14 Solid 2.52 200 1.01 17.62 13.64% NAC#3 NAC#32-2nd floor 0.000 2.244 #14 Solid 2.52 200 1.01 18.14 11.09% NAC#4 Unused 0.000 1.380 #14 Solid 2.52 0.00 20.40 0.00% Aux lAux 0.000 0.000 1#12 Solid 1.59 0.00 20.40 0.00% Total Standbv Current(Amos) 0.060 6.982 Total Alarm Current(Amps) Standbv Time In Hours 24 0.083 Alarm Time In Minutes/60 5 Mins Total Standby AH Required 1.440 0.582 Total Alarm AH Required Total Combined AH Required 2.02 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factorl 1.20 the minimal difference between solid and stranded wire no differential was made_. Minimum Battery AmpHours Required 2.43 Configure Circuits 1 i Print Page r Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA190008 Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt. Number: 30 Panel ID: RPS#8 Ckt. Name: NAC#30-2nd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standbv Alarm Standby Alarm 1 PC21-Ceiling Horn/Strobe(30 cd) 0.000 0.094 0.000 0.094 2 PC21-Ceiling Horn/Strobe(15 cd) 0.000 0.071 0.000 0.142 3 P21-Wall Horn/Strobe(15 cd) 0.000 0.054 0.000 0.162 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 0.398 Ckt. Number. 31 Panel ID: RPS#8 Ckt. Name: NAC#31 -2nd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standbv Alarm Standbv Alarm 20 HW-LF 0.000 0.138 0.000 2.760 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 2.760 Ckt. Number: 32 Panel ID: RPS#8 Ckt.Name: NAC#32-2nd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standbv Alarm 11 HW-LF 0.000 0.138 0.000 1.518 2 SL Wall Strobe(15cd) 0.000 0.041 0.000 0.082 2 P21-Wall Horn/Strobe(75 cd) 0.000 0.137 0.000 0.274 2 P21-Wall Horn/Strobe(110 cd) 0.000 0.185 0.000 0.370 0.000 0.000 Totalsl 0.000 2.244 Ckt.Number: Unused Panel ID: RPS#8 Ckt. Name: Unused Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standbv Alarm 10 HW-LF 0.000 0.138 0.000 1.380 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals! 0.000 1.380 Global Project Values: Project Name:ISmokey Point Senior Living Standby Hours: 24 Project ID:IWAl90008 Alarm Mins:F ABOOM Prepared By: Kristo her Conner,SET Derating Factor: 1.2 Date: 8/19/2019 Voltage Drop Warning Threshold%: 15 Panel ID: IRPS#9 Model: PSN106 Max NAC Current: 3.0 Amps Location: JElectrical Room by Unit 353 Volts: 24 VDC Max Panel Current: 10.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ o Ckt.# Circuit Name Standbv Alarm &Tvpe 1000 Ft. One-Wav Ohms EOL �oDrop BPS10A PSN106 1 0.060 1 0.200 NAC#1 NAC#33-3rd floor 0.000 0.441 #14 Solid 2.52 200 1.01 19.96 2.18% NAC#2 NAC#34-3rd floor 0.000 2.346 #14 Solid 2.52 200 1.01 18.04 11.59% NAC#3 NAC#35-3rd floor 0.000 1.794 #14 Solid 2.52 200 1.01 18.59 8.86% NAC#4 1 NAC#36-3rd floor 0.000 2.172 #14 Solid 2.52 200 1.01 18.21 10.73% Aux JAux 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Total Standby Current(Amps) 0.060 6.953 Total Alarm Current(Amps) Standbv Time In Hours 24 0.083 Alarm Time In Minutes/60 5 Mins Total Standbv AH Required 1.440 1 0.579 Total Alarm AH Required Total Combined AH Required 2.02 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Deratinq Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.42 Configure Circuits l Print Page + _ � I t I Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA190008 i Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt. Number: 33 Panel ID: RPS#9 Ckt. Name: NAC#33-3rd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standbv Alarm Standby Alarm 5 SCL Ceilinq Strobe(15 cd) 0.000 0.041 0.000 0.205 2 PC21-Ceilinq Horn/Strobe(15 cd) 0.000 0.071 0.000 0.142 1 PC21L Ceilino Horn/Strobe(30 cd) 0.000 0.094 0.000 0.094 Unused 0.000 0.000 0.000 0.000 0.000 1 0.000 Totalsl 0.000 1 0.441 Ckt. Number: 34 Panel ID: RPS#9 Ckt. Name: NAC#34-3rd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 17 HW-LF 0.000 0.138 0.000 2.346 Unused 0.000 0,000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.00 1 2.346 Ckt. Number: 35 Panel ID: RPS#9 Ckt. Name: NAC#35-3rd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 13 HW-LF 0.000 0.138 0.000 1.794 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1 1.794 Ckt. Number: 36 Panel ID: RPS#9 Ckt. Name: NAC#36-3rd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 12 HW-LF 0.000 0.138 0.000 1.656 1 P21L Wall Horn/Strobe 05 cd) 0.000 0.054 0.000 0.054 1 P21L Wall Horn/Strobe(75 cd) 0.000 0.137 0.000 0.137 1 P2WH-LF 0) 177cd 0.000 0.325 0.000 0.325 0.000 0.000 Totalsl 0.000 2.172 r, � ��� Global Project Values: Project Name:JSmokeV Point Senior Livinq Standby Hours: 24 A6 � Project ID:IWAI90008 Alarm Mins:� I Prepared By: Kristopher Conner.SET Derating Factor: 1.2 Date: 8/19/2019 Voltage Drop Warning --— Threshold% Panel ID: I RPS#10 Model: PSN106 Max NAC Current: 3.0 Amps Location: Electrical Room by Unit 344 Volts: 24 VDC Max Panel Current: 10.0 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm &Type 1000 Ft. One-Way Ohms EOL BPS10A PSN106 1 0.060 0.200 NAC#1 NAC#37-3rd floor 0.000 2.346 #14 Solid 2.52 200 1.01 18.04 11.59% NAC#2 NAC#38-3rd floor 0.000 2.021 #14 Solid 2.52 200 1.01 18.36 9.99% NAC#3 NAC#39-3rd floor 0.000 2.484 #14 Solid 2.52 200 1.01 17.90 12.27% NAC#4 INAC#40-3rd floor 0.000 0.471 #14 Solid 2.52 200 1.01 19.93 2.33% Aux JAux 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Total Standbv Current(Amos) 0.060 7.522 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 5 Mins Total Standbv AH Required 1.440 0.627 Total Alarm AH Required Total Combined AH Reouired 2.07 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.48 f Configure Circuits l I Print Page J Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA190008 Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt. Number: 37 Panel ID: RPS#10 Ckt. Name: NAC#37-3rd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 17 HW-LF 0.000 0.138 0.000 2.346 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 2.346 Ckt. Number: 38 Panel ID: RPS#10 Ckt. Name: NAC#38-3rd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 HW-LF 0.000 0.138 0.000 0.690 2 SL Wall Strobe(15cd) 0.000 0.041 0.000 0.082 3 P2WH-LF cD, 177cd 0.000 0.325 0.000 0.975 2 P21-Wall Horn/Strobe(75 cd) 0.000 0.137 0.000 0.274 0.000 0.000 Totalsl 0.000 2.021 Ckt. Number: 39 Panel ID: RPS#10 Ckt. Name: NAC#39-3rd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 18 HW-LF 0.000 0.138 0.000 2.484 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 2.484 Ckt. Number: 40 Panel ID: RPS#10 Ckt. Name: NAC#40-3rd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 SCL Ceilina Strobe(15 cd) 0.000 0.041 0.000 0.164 3 PC2L Ceiling Horn/Strobe N5 cd) 0.000 0.071 0.000 0.213 1 PC2L Ceilinq Horn/Strobe(30 cd) 0.000 0.094 0.000 0.094 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.471 Global Project Values: Project Name:I Smokey Point Senior Living Standby Hours: 24 M Project ID:JWA190008 = Alarm Mins:� Prepared By: Kristopher Conner, SET Derating Factor: 1.2 Date: 8/19/2019 Voltage Drop Warning Threshold%: 15 Panel ID: RPS#11 Model: BPS10A Remote Booster Power Supply Max NAC Current: 3.0 Amps Location: JElectrical Room by Unit 320 Volts: 24 VDC Max Panel Current: 10.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ a la Ckt.# Circuit Name Standby Alarm &Type 1000 Ft. One-Way Ohms EOL Drop BPS10A BPS10A panel 1 0.075 0.205 NAC#1 NAC#41 -3rd floor 0.000 0.247 #14 Solid 2.52 200 1.01 20.15 1.22% NAC#2 NAC#42-3rd floor 0.000 1.656 #14 Solid 2.52 200 1.01 18.73 8.18% NAC#3 NAC#43-3rd floor 0.000 2.208 #14 Solid 2.52 200 1.01 18.17 10.91% NAC#4 NAC#44-3rd floor 0.000 1.380 #14 Solid 2.52 200 1.01 19.01 6.82% Aux lAux 0.000 0.000 1#12 Solid 1 1.59 0.00 20.40 0.00% Total Standby Current(Amps) 0.075 5.696 Total Alarm Current(Amps) Standbv Time In Hours 24 0.083 Alarm Time In Minutes/60 5 Mins Total Standbv AH Required 1.800 0.475 Total Alarm AH Required Total Combined AH Reauired 2.27 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiplv By The Deratinq Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmDHours Required 2.73 Configure Circuits 1 ( Print Page 1 Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA190008 Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt. Number: 41 Panel ID: RPS#11 Ckt. Name: NAC#41 -3rd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 PC2L Ceilinq Horn/Strobe(30 cd) 0.000 0.094 0.000 0.094 1 PC2L Ceiling Horn/Strobe(15 cd) 0.000 0.071 0.000 0.071 2 SCL Ceiling Strobe(15 cd) 0.000 0.041 0.000 0.082 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.247 Ckt. Number: 42 Panel ID: RPS#11 Ckt. Name: NAC#42-3rd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standbv Alarm 12 HW-LF 0.000 0.138 0.000 1.656 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1656 Ckt. Number: 43 Panel ID: RPS#11 Ckt. Name: NAC#43-3rd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 16 HW-LF 0.000 0.138 0.000 2.208 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 2.208 Ckt. Number: 44 Panel ID: RPS#11 Ckt.Name: NAC#44-3rd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 10 HW-LF 0.000 0.138 0.000 1.380 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Tota Is 0.000 1.380 Global Project Values: jProject Name:ISmokey Point Senior Living Standby Hours: 24 A84� Project ID: WA190008 Alarm Mins:� � Prepared By:I Kristo her Conner,SET Derating Factor: 1.2 Date: 8/19/2019 Voltage Drop Warning Threshold%: 15 Panel ID: IRPS#12 Model: PSN106 Max NAC Current: 3.0 Amps Location: Electrical Room by Unit 309 Volts: 24 VDC Max Panel Current: 10.0 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm &Type 1000 Ft. One-Wav Ohms EOL BPS10A PSN106 1 0.060 0.200 NAC#1 NAC#45-3rd floor 0.000 0.400 #14 Solid 2.52 200 1.01 20.00 1.98% NAC#2 NAC#46-3rd floor 0.000 2.524 #14 Solid 2.52 200 1.01 17.86 12.47% NAC#3 NAC#47-3rd floor 0.000 2.760 #14 Solid 2.52 200 1.01 17.62 13.64% NAC#4 Unused 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% Aux JAux 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Total Standbv Current(Amps) 0.060 5.884 Total Alarm Current(Amps) Standbv Time In Hours 24 0.083 Alarm Time In Minutes/60 5 Mins Total Standbv AH Required 1.440 0.490 Total Alarm AH Required Total Combined AH Required 1.93 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Deratina Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required' 2.32 Configure Circuits I Print Page Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA190008 Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt. Number: 45 Panel ID: RPS#12 Ckt. Name: NAC#45-3rd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 PC21-Ceiling Horn/Strobe(30 cd) 0.000 0.094 0.000 0.094 2 PC21-Ceiling Horn/Strobe(15 cd) 0.000 0.071 0.000 0.142 4 SCL Ceilinq Strobe(15 cd) 0.000 0.041 0.000 0.164 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 0.400 Ckt. Number: 46 Panel ID: RPS#12 Ckt. Name: NAC#46-3rd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 11 HW-LF 0.000 0.138 0.000 1.518 2 SL Wall Strobe(15cd) 0.000 0.041 0.000 0.082 2 P21-Wall Horn/Strobe(75 cd) 0.000 0.137 0.000 0.274 2 P2WH-LF (cD 177cd 0.000 0.325 0.000 0.650 0.000 0.000 Totalsl 0.000 2.524 Ckt. Number: 47 Panel ID: RPS#12 Ckt. Name: NAC#47-3rd floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standbv Alarm Standby Alarm 20 HW-LF 0.000 0.138 0.000 2.760 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 2.760 Ckt. Number: Unused Panel ID: RPS#12 Ckt. Name: Unused Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 1 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1 0.000 Global Project Values: Project Name:ISmokey Point Senior Livinq Standby Hours: 24 Project ID: WA190008 Alarm Mins:r——5 A6��M Prepared By:I Kristopher Conner,SET Derating Factor: 1.2 Date: 8/19/2019 Voltage Drop Warning Threshold% Panel ID: IRPS#13 Model: PSN106 Max NAC Current: 3.0 Amps Location: JElectrical Room by Unit 453 Volts: 24 VDC Max Panel Current: 10.0 Amps Current Draw Wire AW G Ohms Per Length(ft) Actual Volts @ o Ckt.# Circuit Name Standbv Alarm &Tvoe 1000 Ft. One-Wav Ohms EOL �oDrop BPS10A PSN106 1 0.060 0.200 NAC#1 NAC#48-4th floor 0.000 0.441 #14 Solid 2.52 200 1.01 19.96 2.18% NAC#2 NAC#49-4th floor 0.000 2.346 #14 Solid 2.52 200 1.01 18.04 11.59% NAC#3 NAC#50-4th floor 0.000 1.794 #14 Solid 2.52 200 1.01 18.59 8.86% NAC#4 NAC#51 -4th floor 0.000 2.169 #14 Solid 2.52 200 1.01 18.21 10.72% Aux lAux 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Total Standbv Current(Amos1 0.060 6.950 Total Alarm Current(Amps) Standbv Time In Hours 24 0.083 Alarm Time In Minutes/60 5 Mins Total Standbv AH Required 1.440 0.579 Total Alarm AH Required Total Combined AH Required 2.02 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of MUltioly By The Deratina Factor 1.20 the minimal difference between solid and stranded wire no differential was made_ Minimum Battery AmoHours Required 2.42 Configure Circuits I I Print Page i Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA190008 Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt. Number: 48 Panel ID: RPS#13 Ckt. Name: NAC#48-4th floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standbv Alarm 5 SCL Ceiling Strobe(15 cd) 0.000 0.041 0.000 0.205 2 PC21-Ceilinq Horn/Strobe(15 cd) 0.000 0.071 0.000 0.142 1 PC2L Ceilinq Horn/Strobe(30 cd) 0.000 0.094 0.000 0.094 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 0.441 Ckt. Number: 49 Panel ID: RPS#13 Ckt. Name: NAC#49-4th floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 17 HW-LF 0.000 0.138 1 0.000 2.346 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 1 0.000 Totalsl 0.000 1 2.346 Ckt. Number: 50 Panel ID: RPS#13 Ckt. Name: NAC#50-4th floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 13 HW-LF 0.000 0.138 0.000 1.794 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0,000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1.794 Ckt. Number: 51 Panel ID: RPS#13 Ckt-Name: NAC#51 -4th floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standbv Alarm Standbv Alarm 12 HW-LF 0.000 0.138 0.000 1.656 1 SL Wall Strobe(15cd) 0.000 0.041 0.000 0.041 1 PC21-Ceiling Horn/Strobe(75 cd) 0.000 0.147 0.000 0.147 1 P2WH-LF 177cd 0.000 0.325 0.000 0.325 0.000 0.000 Totalsl 0.000 2.169 Global Project Values: Project Name: Smokey Point Senior Living Standby Hours: 24 Project ID: WA190008 Alarm Mins:� ABD�M Prepared By: Kristopher Conner, SET Derating Factor l ? Date: 8/19/2019 Voltage Drop Warning �— Threshold% 15 Panel ID: IRPS#14 Model: PSN106 Max NAC Current: 3.0 Amps Location: JElectrical Room by Unit 444 Volts: 24 VDC Max Panel Current: 10.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ o Ckt.# Circuit Name Standbv Alarm &Tvpe 1000 Ft. One-Wav Ohms EOL �oDrop BPS10A PSN106 1 0.060 0.200 NAC#1 NAC#52-4th floor 0.000 2.346 #14 Solid 2.52 200 1.01 18.04 11.59% NAC#2 NAC#53-4th floor 0.000 2.021 #14 Solid 2.52 200 1.01 18.3 99.99% NAC#3 NAC#54-4th floor 0.000 2.484 914 Solid 2.52 200 1.01 17.90 12.27% NAC#4 NAC#55-4th floor 0.000 0.448 #14 Solid 2.52 200 1.01 19.95 2.21% Aux Aux 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Total Standbv Current(Amps) 0.060 7.499 Total Alarm Current(Amps) Standbv Time In Hours 24 0.083 Alarm Time in Minutes/60 5 Mins Total Standby AH Required 1.440 0.625 Total Alarm AH Required Total Combined AH Required 2.06 Wire resistances are based upon an ambient temperature of 72 degrees F, Because of MUltioly By The Deratinq Factor 1.20 the minimal difference between solid and stranded wire no differential was made, Minimum Battery AmpHours Required 2.48 Configure Circuits I Print Page .ti �! Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA190008 Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt. Number: 52 Panel ID: RPS#14 Ckt. Name: NAC#52-4th floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 17 HW-LF 0.000 0.138 0.000 2.346 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1 2.346 Ckt. Number: 53 Panel ID: RPS#14 Ckt. Name: NAC#53-4th floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 HW-LF 0.000 0.138 0.000 0.690 2 SL Wall Strobe(15cd) 0.000 0.041 0.000 0.082 3 P2W H-LF P 177cd 0.000 0.325 0.000 0.975 2 P21-Wall Horn/Strobe(75 cd) 0.000 0.137 0.000 0.274 0.000 0.000 Totals 0.000 1 2.021 Ckt. Number: 54 Panel ID: RPS#14 Ckt. Name: NAC#54-4th floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 18 HW-LF 0.000 0.138 0.000 2.484 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.00 1 2.484 Ckt. Number: 55 Panel ID: RPS#14 Ckt. Name: NAC#55-4th floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 SCL Ceiling Strobe(15 cd) 0.000 0.041 0.000 0.164 3 PC21-Ceilinq Horn/Strobe(15 cd) 0.000 0.071 0.000 0.213 1 P2L Wall Horn/Strobe(30 cd) 0.000 0.071 0.000 0.071 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1 0.448 Global Project Values: Project Name:ISmokey Point Senior Living Standby Hours: 24 AB JVI Project ID:IWAI90008 Alarm Mins:� � Prepared By: Krist her Conner,SET Derating Factor: 1.2 Date 8/19/2019 Voltage Drop Warning Threshold%: 15 Panel ID: IRPS#15 Model: PSN106 Max NAC Current: 3.0 Amps Location: JElectrical Room by Unit 420 Volts: 24 VDC Max Panel Current: 10.0 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm &Type 1000 Ft. One-Way Ohms EOL BPS10A PSN106 1 0.060 0.200 NAC#1 NAC#56-4th floor 0.000 0.247 #14 Solid 2.52 200 1.01 20.15 1.22% NAC#2 NAC#57-4th floor 0.000 1.656 #14 Solid 2.52 200 1.01 18.73 8.18% NAC#3 NAC#58-4th floor 0.000 2.208 #14 Solid 2.52 200 1.01 18.17 10.91% NAC#4 NAC#59-4th floor 0.000 1.380 #14 Solid 2.52 200 1.01 19.01 6.82% Aux JAux 0.000 0.000 #12 Solid 1.59 0.00 1 20.40 0.00% Total Standbv Current(Amos) 0.060 5.691 Total Alarm Current(Amps) Standbv Time In Hours 24 0.083 Alarm Time In Minutes/60 5 Mins Total Standby AH Required 1.440 0.474 Total Alarm AH Required Total Combined AH Required 1.91 1 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.30 1 Configure Circuits l I Print Page Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA190008 Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt. Number: 56 Panel ID: RPS#15 Ckt. Name: NAC#56-4th floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 PC21-Ceiling Horn/Strobe(30 cd) 0.000 0.094 0.000 0.094 1 PC2L Ceiling Horn/Strobe(15 cd) 0.000 0.071 0.000 0.071 2 SCL Ceilinq Strobe(15 cd) 0.000 0.041 0.000 0.082 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1 0.247 Ckt. Number: 57 Panel ID: RPS#15 Ckt. Name: NAC#57-4th floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 12 HW-LF 0.000 0.138 0.000 1.656 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1.656 Ckt. Number: 58 Panel ID: RPS#15 Ckt. Name: NAC#58-4th floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standbv Alarm 16 HW-LF 0.000 0.138 0.000 2.208 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1 2.208 Ckt. Number. 59 Panel ID: RPS#15 Ckt. Name: NAC#59-4th floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standbv Alarm 10 HW-LF 0.000 0.138 0.000 1.380 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1.380 Global Project Values: Project Name:I Smokey Point Senior Living Standby Hours: 24 A MSUU1 Project ID: WA190008 Alarm Mins:� I Prepared By: Kristopher Conner, SET Derating Factor: 1.2 Date: 8/19/2019 Voltage Drop Warning Threshold%: 15 Panel ID: I RPS#16 Model: PSN106 Max NAC Current: 3.0 Amps Location: JElectrical Room by Unit 409 Volts: 24 VDC Max Panel Current: 10.0 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standbv Alarm &Type 1000 Ft, One-Way Ohms EOL BPS10A PSN106 1 0.060 0.200 NAC#1 NAC#60-4th floor 0.000 0.366 #14 Solid 2.52 200 1.01 20.03 1.81% NAC#2 NAC#61 -4th floor 0.000 2.544 #14 Solid 2.52 200 1.01 17.84 12.57% NAC#3 NAC#62-4th floor 0.000 2.760 #14 Solid 2.52 200 1.01 17.62 13.64% NAC#4 Unused 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% Aux lAux 0.000 0.000 #12 Solid 1 1.59 1 0.00 20.40 0.00% Total Standbv Current(Amos) 0.060 1 5.870 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 5 Mins Total Standbv AH Required 1.440 0.489 Total Alarm AH Required Total Combined AH Reauired 1.93 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Deratinq Factor, 1.20 the minimal difference between solid and stranded wire no differential was made, Minimum Battery AmpHours Required 2.32 Configure Circuits I Print Page f e Circuit Configuration Project Information Project Name: Smokey Point Senior Living Project ID: WA190008 Prepared By: Kristopher Conner, SET Date: 8/19/2019 Ckt. Number: 60 Panel ID: RPS#16 Ckt. Name: NAC#60-4th floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 PC2L Ceiling Horn/Strobe(30 cd) 0.000 0.094 0.000 0.094 2 P2L Wall Horn/Strobe(15 cd) 0.000 0.054 0.000 0.108 4 SCL Ceiling Strobe(15 cd) 0.000 0.041 0.000 0.164 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 0.366 Ckt. Number: 61 Panel ID: RPS#16 Ckt. Name: NAC#61 -4th floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 11 HW-LF 0.000 0.138 0.000 1.518 2 SL Wall Strobe (15cd) 0.000 0.041 0.000 0.082 2 PC2L Ceiling Horn/Strobe(75 cd) 0.000 0.147 0.000 0.294 2 P2WH-LF(c-) 177cd 0.000 0.325 0.000 0.650 0.000 0.000 Totals 0.000 2.544 Ckt. Number: 62 Panel ID: RPS#16 Ckt. Name: NAC#62-4th floor Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standbv Alarm Standby Alarm 20 HW-LF 0.000 0.138 0.000 2.760 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1 2.760 Ckt.Number: Unused Panel ID: RPS#16 Ckt. Name: Unused Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1 0.000 K_ r i A6 Mr� Project: Cedar Pointe Apartments Arlington, WA Customer: R & S Electric Arlington, WA Fire Alarm Equipment Submittals CITY OF ARLINGTON BUILDING DEPARTMENT COPY APPROVED OFFICE DATE O BY o NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR Received .. / SEP 12 203 Designing Innovation. Building Connections. Maintaining Trust. www.abcomllc.com .� i ._i � _ ,�. „ . ,- - . _. . . , A6OOMW Table of Contents Fire Alarm Fire Alarm Control Panel.....................................................................................................3 RemoteAnnunciator...........................................................................................................7 SmokeDetectors.................................................................................................................9 HeatDetector....................................................................................................................12 InputModules...................................................................................................................15 RelayModules...................................................................................................................17 PullStations ......................................................................................................................19 Communicator..................................................................................................................21 NotificationAppliances.....................................................................................................23 Designing Innovation. Building Connections. Maintaining Trust www.abcomllc.com Honeywell A ( - - v`»c -u_ Ri A;a�i'TI 1. ont-rol Pc1ncl SILENT' KNIC:HT 6820 Addressable Fire Alarm Control Panel The 6820 is an addressable fire alarm control panel(FACP)and is a direct replacement for the 5820XL FACP_The 6820 can be configured to achieve a point capacity of 1110 points and connect up to 17 panels in a single communications link. The 6820 has one built-in signaling line circuit(SLC),which can support 159(SK)System Sensor-sensors and 159 SK modules or 127 (SD)Hochiki' devices per loop.To increase point capabilities,additional SLC loops can be added using the 6815 SLC expander for SK devices or the 5815XL expander for SD devices,increasing the point capacity to a 6820 maximum of 1110 points for SK devices and 635 points for SD devices. Three additional SLCs are needed to reach 1110 points(SK devices). The 6820 also has a form-C trouble relay,two Four additional SLCs are needed to reach 635 points(SD devices). programmable form-C relays,along with powerful A common communications and annunciation link allows up to 17 Features such as drift compensation,pre-trouble panels to be connected via copper or fiber optic cable.A designated maintenance alert,a built-in sensor test to panel is configured as the communicator for all panels in the link for complywith NFPA 72 calibration testing convenient single-point communications. It also has a built-in,dual- requirements,and calibration trouble alert. line POTS and IP communicator with additional cellular options The 6820 supports a variety of devices,including available. the 6860.5860,and 6855 remote annunciators. The 6820 system can be enhanced by adding modules such as the 5824 serial parallel printer interface module(for 6860 remote annunciator which also has four programmable function printing system reports),the 5496 NAC expander, buttons to help automate tasks and reduce time spent at the panel. 5895XL power module,and SK or SD devices, SWIFT'wireless compatibility provides options for wireless detection through a Class A mesh network.It is ideal for hard-to-wire locations, buildings where newwiring is not allowed,or to provide an easy install fire system for new construction projects.SWIFT devices can be combined with other hard-wired 6820 compatible devices. I- E A ' UK �_S -& R I- Nl 1- 1 1 D • Capable of providing Connect up to 17 Built-in dual path Programmable date 71exput-,circuits can up to 1110 points for panels on one site with POTS and IP setting for automatic be individually enhanced design convenient single- communications with and convenient programmed to flexibility, Additional point access using the optional cellular Daylight Saving Time function as Signal Line Circuits SK-NIC Network models available for changes notification circuits, can be added until Interface Card. reliable backup Pour user- auxiliary power t maximurr point levels Connected panels can reporting programmable outputs,or initiating Il are reached have mixed compatible 6860 annunciator with buttons minimize circuits that support rACP models both 2-and 4-wire • Built-in U5B interface a 4 x 40 urge display time spent executing for convenient and • Convenient Jur??pStart' auto complex or routine Smoke detectors • quick programming field-upgradeabie programming reduces tasks firmware installation time SIGNAL LINE CIRCUIT(SLC) system silenced and system power_ water flow,sprinkler supervisory iDACT The 6815 signal line circuit(SLC) System operations include silencing non-coded)signaling services. supports multiple device types of SK alarms and troubles, resetting alarms • UL Listed:S2766 protocol,while the 5815XLsignal line and the display of alarm troubles and circuit(SLC. supports multiple device CSFM: 7165-0559 0500 n�emory.Thesystem's non-volatile types of SD protocol,You cannot mix SD event history buffer stores 1,000 FDNY:COA#6249 and SK SI-C devices on a FACP, events for viewing from the built- • FM approved The 6820 has one built-in signaling in or remote annunciator.System ORDERING INFORMATION line circuit(SLC)which supports multiple operations can be initiated with a 6820 Addressable Fire Alarm devices.Additional points mechanical firefighter's key of a valid Control Panel (Red cabinet) can be added using the 6815 SLC 4-to 7-digit operator's code, expanders to increase overall capacity to PROGRAMMING COMPATIBLE ANNUNCIATORS 1,110 maximum points(SK devices)or by 6860:4x40 LCD remote fire annunciator The 6820 system offers several options adding up to four 5815XL SLC expanders to simplify and speed-up programming, (4 lines and up to 160 characters)per to reach 635 maximum points(SD JumpStart"Auto Programming system;four programmable buttons devices),The number of SLCs which can 5860:4x20 LCD remote fire minimizes programming required to be used within one system is limited by annunciator.5860 is gray;586OR is red start a new system.The built-in keypad, point count.(See the Manual for or she 6800,5860 or 6855 remote 6855:4x20 LCD remote fire annunciator additional information..) 5865-3 or 5865-4:LED annunciators annunciators give you on-site access to The 6820 SLC loops support multiple current system programming, can display up to 30 LEDs(15 red and device types, maintenance alerts,and a Programi ring can also be accomplished 15 yellow).The 5865-4 has key switches built-in sensor test to complywith NFPA using the Windows -based Honeywell for silence and reset,and a system 72 calibration testing requirements. Fire Software Suite(HFSS)program. trouble LED INDICATOR LIGHTS SOFTWARE TOOLS 5880:The 5880 LED/10 module • General Alarm(Red): Flashes if in SKST:Silent Knight Selection Tool has 40 programmable LED outputs and eight supervised dry contact inputs alarrn,solid when alarm is silenced provides the installer or design architect which are useful for custom applications. • Supervisory(Yellow):Flashes if a with a Windows software system You can use up to eight 5880 modules supervisory condition exists,solid configuration tool to create a detailed on one control panel for maximum when supervisory is silenced Bill of Material(BOM)and battery flexibility,Its compact size allows • System Troubles(Yellow):Flashes calculations, mounting inside the annunciator,or in if a trouble condition exists: HFSS: Honeywell Fire Software Suite an accessory cabinet. solid when trouble is silenced provides communication and panel 6820 COMPATIBLE DEVICES AND programming,detector status,event ACCESSORIES • System Silenced(Yellow): history and additional data, Requires a See the data sheets listed below for a On when an alarm,trouble or complete listing of the SK.SD or SWIFT supervisory condition has been PC running Microsoft Windows,'. devices. 53623:SK Devices Data Sheet silenced but not yet cleared ADDITIONAL INFORMATION 53624:SD Devices Data Sheet • System Power(Green):Flashes Twisted-unshielded pair wire is 350614,3506168c350618:SWIFT wireless devices for AC failure:solid when recommended,The 6820 also has 13 For a complete and current listing of power systems are normal preset notification cadence patterns compatible devices and accessories,visit USER INTERFACE www.sitentknight.com (including ANSI 3.41). Important:You cannot mix SK and SD The 6820 built-in 4 x 20 annunciator AGENCY LISTINGS AND APPROVALS devices in the same fire alarm system. with 80 character LCD display NFPA 13,NFPA 15,NFPA 16,NFPA 70, I4 and large easy-to-use tactile NFPA 72:Central station;remote touchpad can be used for system Signaling;Local Protective Signaling operation,programming and Systems,Auxiliary Protected Premises maintenance.It has five LEDs for Unit;Water Deluge releasing service, alarm,supervisory,system trouble, Suitable for automatic,manual, Page 2 of 4—351610:13 9/26/2018 f �. SK COMPATIBLE ADDRESSABLE B200S-LF:Low.frequency intelligent WSK-PHOTO-T:Wireless criteria DEVICES sounder base photoelectric srnoke detector with thertnal SK-ACCLIMATE:Multi criteria B224RB(-IV,-WH):Relay base detection(135°F fixed temperature)and photoelectric smoke detectorwilh thern•ial B224RB: Relay base B510W 4"base 135'Ffixed temperature B224B1(-IV,-WH):Isolator base WSK-HEAT:Yireless Heat,(135'F fixed SK-BEAM:Reflected beam smoke detector B224B1: Isolator base temperature)and B510W 4"base without test feature WSK-HEAT-ROR:Wireless heal-POP SK-BEAM-T: beam smoke SD COMPATIBLE ADDRESSABLE (135'17 fixed temperature)and 8510`JV 4" detectorwith test feat..ire DEVICES base SK-CONTROL:Supervised control module SD505-6AB:Addressable 6"base WSK-MONITOR:Wireless monitor module SK-CONTROL-6:Six circuit supervised SD505-6113:Addressable 6"short circuit WSK-RELAY:Wireless relay module control module isolator base W-USB:SWIFT Tools USB transceiver used SK-DUCT:Photoelectric duct smoke SD505-61RB:Addressable 6"relay base For communication with SWIFT devices detector with extended air speed range SD505-6SB:Addressable 6'sounder base SK-FIRE-CO:Four criteria fire and carbon SD500-AIM:Addressable input module SBUS ACCESSORIES monoxide detector (switch input) 6815:Each Single Line Circuit allows for SK-HEAT:Fixed thermal detector(135'F) SD500-ANM:Addressable notification an additional 159 SK modules and 159 SK SK-HEAT-W:Fixed thermal detector module sensors to be added to the system-up to (135°F),white SD500-ARM: Addressable relay module 1,110 total points.Supports System Sensor SK-HEAT-ROR:Fixed rate of rise detector SD505-DTS-K: Remote test switch and SK devices only. (135°F) LED indicator for the SD505-DUCTR 5815XL:Each Single Line Circuit provides SK-HEAT-ROR-W:Fixed rate of rise detector SD505-DUCT:Addressable Duct Smoke an additional 127 SD devices to be added to (135°F),white Detector, the system-for a maximum of 635 points, SK-HEAT-HT:Fixed high temperature SD505-DUCTR:Addressable Duct Supports SD devices only, thermal detector(190'F) Detector housing with relay base. 5496:A 6 amp notification power expander SK-HEAT-HT-W:Fixed high temperature SD505-HEAT:Absolute temperature heat with four power-limited notification thermal detector(190°F),white p appliance circuit outputs. detector.Trip point range from SK-ISO:Fault isolator module 135°F-150°F(0`CG37°C). 5883:Relay Interface.Provides 10 Form C SK-MINIMON:Mini monitor module SD500-LIM:Addressable Line isolator relays. SK-MONITOR:Monitor module module 5824:Seria(/Parallel Printer Interface SK-MONITOR-2:Dual input monitor SD500-MIM:Addressable Mini input Module for printer connection. 1-nodule monitor module(switch input) 5895XL:Power Supply with six Flexput" SK-MON-10:10 input monitor module SD505-PHOTO:Photoelectric smoke circuits,and two Form C relays.Max.15 per SK-PHOTO:Photoelectric smoke detector detector system. SD500-PS/-PSDA:Addressable Sin 5815RMK:Remote mounting kir, detector, or SK-PHOTO-W:white Photoelectric smoke d Dimensions 10 3/8"W x 10�-3/16"H x 3"D detector,white dual action pull station SK-PHOTO-T:Photoelectric smoke detector SD500-SDM:Addressable smoke detector COMMUNICATION OPTIONS with thermal(135°F fixed temperature) module CELL-CAB-SK:Cellular communicator, SK-PHOTO-T-W: Photoelectric smoke AUDIBLE/VISIBLE DEVICES metal enclosure with lock/key* detector with thermal(135°F fixed CELL-MOD:Cellular communicator,plastic temperature),white These AV devices are all2-wire•Color:-R" SK-PHOTOR:Photoelectric detector with indicates red;-W'denotes white.For a enclosure* remote test capability complete listing of Silent Knight AV devices *Sole path,powered by panel. SK-PHOTO-R-W: Photoelectric detector go to www.sitentknight.com. IPGSM-4G:Dual path fire alarm with remote test capability,white communicator,cellular and/or IP(primary CHSRL/CHSWL:Wallchime/strobe or backup,selectable) SK-PULL-SA:Addressable single action pull CHSCRL/CHSCWL:Ceiling chime/strobe station SK-IP-2:Remote reporting via the Internet. CHRL/CHWL:Wall chime Requires a VisorAlarm'receiver atthe SK-PULL-DA:Addressable dual action pull HRL/HWL:Wall horn central station station P2RL/P2WL:Wall horn/strobe SK-RELAY:Addressable relay module PC2RL/PC2WL:Ceiling horn/strobe MISC.ACCESSORIES SK-RELAY-6:Addressable Six relay control SRL/SWL:Wall strobe SK-NIC:Network Interface Card.Provides module common communications link for the 6820. SK-RELAYMON-2:Addressable Dual relay/ SCRL/SCWL:Ceiling strobe p� monitor module SPSCRL/SPSCWL:Ceiling speaker/strobe SK-NIC-KIT:Installation Accessory Kit SK-ZONE:Addressable zone interface SPSRL/SPSWL:Wall speaker/strobe SK-FML:Fiber-Optic Multi Mode, module SPRL/SPWL:Wall speaker transmitter and receiver SK-ZONE-6:Six zone interface module SPCRL/SPCWL:Ceiling speaker SK-FSL:Fiber-Optic Single Mode B300-6(-IV):6"base for SK-W Series RBB:Remote battery box_accessory cabinet SWIFT WIRELESS DEVICES for batteries that are too large to fit in the B210LP:6"mounting base FACP cabinet.Dimensions:16"W x 10"H x B501(-WHITE,-IV,-BL):4"Flan Bless base SWIFT is only compatible with 9 6"D(406mm W x 254mm H x 152mm D). B501:4`Flan Bless mounting base Systei7�Sensor(SK)devices.ltis not g g compatible with Hochi.ki(SD)devices, SK-SCK:Seismic Compliance Kit used to B200S(-IV,-WH): Intelligent sounder base securely fasten batteries to the fire oanel. B20OS:Intelligent sounder base WSK-WGI:Wireless Gatev,vay B200S-LF(-IV,-WH):Low-frequency WSK-PHOTO:Wireless Photoelectric smoke intelligent sounder base, detector Page 3 of 4—351610:13 9/26/2018 r 6820 TechnicalL Specifications PHYSICAL FLEXPUT CIRCUITS Flexput',Honeywell", Overall Dimensions:16.36"W x 26.37"H x 3 91"D Six programmable circuits which can be J'umpstart'.Silent Kniq_ht`, Shipping Weight:32 lbs programmed individually as: SWIFT-',and System Sensor are registered Color:Red Notification Appliance Circuits:3A a,27.4VDC Liaden,arks of Honeywell per circuit,power-limited(with a panel maximum International Inc, ENVIRONMENTAL current or 6A) Operating Temperature:32'JF to 120°F (0°C to Auxiliary power circuits:3A ac 274VDC per circuit. Hochiki' is a reg;stered mark of Hochiki 49°C) power-limited trade Corporation.Miciosoft' Humidity:0 to 93%relative humidity(non- Initiating Circuits(Circuits 5 and 6 Only):100nnA and Windows-are condensing) 3 274VDC per circuit,power lii-nited registered trademarks of Microsoft Corporation ELECTRICAL Supports Class B(Style 4)and Class A(Style 6) This document is not 6820 Primary AC:120AC,a)60Hz,3.3A Total configuration For SLC,SBUS,and Flexput circuits intended to be used for Accessory Load:6A a)27.4VDC power-limited installation purposes,We Standby Current:190mA WIRING:See the product manual for wiring details try to keep our product Alarm Current:250rnA nformation up-to Battery Charging Capacity:7 to 35AH date and accurate.Wecannot cover all specific Battery Size:18AH max.allowed in control panel applications or anticipate cabinet,Larger capacity batteries can be housed in all requirements All RBB accessory cabinet. specifications are subject to change without notice For Technical Support,call 800-446-6444 Honeywell Silent Knight 12 Clintonville Road Northford,CT 06472 Honeywell 800-328-0103 351610 I B 109/18 www.sllentknlght.cOm 9 2018 Honeywell International Irc 13 SILENT' TC\iT(:T IT Honeywell ®SILENT' KNIGHT 6860 Remote Annunciator The 6860 remote annunciator can be used to view system status indicators for Honeywell Silent Knight fire alarm control panels(FACPs)from anywhere within the system.It provides a convenient way to view system status indicators. The 6860 comes in a locked,key controlled cabinet-combining security with easy access_It does not require a code or firefighter's key to silence or reset a panel,and also has convenient separate scroll buttons for alarm, supervisory and trouble conditions The remote annunciator communicates with the main fire alarm control panel through an RS-485 connection. The 6860 has a large 160 character,4 x 40 display and four programmable buttons.These features provide more options for set-up and operation when compared to similar remote annunciators. 6860 The 6860 can be surface or flush mounted.The RA-100TR trim ring can be used for surface mounts. COMPATIBILITY The 6860 is compatible with the following Honeywell Silent Knight FACPs: • 6820:Addressable fire alarm control panel with up to 1,110 addressable points • 6820EVS:Addressable fire alarm control panel with an emergency voice system,up to 1,110 addressable points • 6808:Addressable fire alarm control panel with up to 198 addressable points • 6700:Addressable fire alarm control panel with up to 100 addressable points FEATUk LIEN ; i I • _(jw "ne.-CD Easily view Current o/ith 40 cnaractr�rs per status by alarms. t easier?o.monitor tnr(xugh a riser rodn cr furtc[ior) key:,for fog' lii:e; L 6 0 characters superviseries.or -Ind respond to stem=ls firefiyh±er's key Imp;hued ef;iciencies proviaies am�sl�.,spice troubles cliHrlgcs, Ch'y;ncd.t.ide: Support nor and tine-savings: f con'! I tinq )n-dUarri p.ezo simultaneo�is use of Alarm,Sujpervisory; frees urn rime spent at _ . Operating nsessages Silence and AC Povder the panel sounder audibly indicate—;, multiple 686 s Larger<e.ypad bu�i:ons ndicates alarms, _ Comfortable tactical (,an ire flush or niaKesrt a esiest" trO ihles,an d • Accommodates wiring feel and clear audible surrar,e mour-ited,Trim, rnin;e�rveri•orsystern super sories lengths up to6000ft. confinnatrunsupports ring'jvailob[afu,- 4 i R,-._, 37 from the control pane! arrurate for added design and proyramminy and install flexibility easy operation 6860 Techinica[ Specifications Review Events Fora complete listing of ail Individually by Alarms, Supervisories,or Troubles 160Character compliance approvals and Display certifications pleasevlsit LED Status www.sitentknight.com Indite eIre Microsoft.Windows,and the Windows Logo are registered trademarks or ti ademarks of Large Buttons for vlia osoft Corporation System Silence,Reset, Event Acknowledge, Silent Knight and -- and Fire Drill Honeywell- are registered ti ademal ks of Honeyweil International Inc. m This document is not p intended to be used for Ergonomic installation purposes.We Designed Keypad ti y to keep our product (Hidden when door is closed) Information up-to date and accurate.We cannot cover all specific applications or anticipate Numeric Keypad all requirements All FourP (Hidden-when door is closed) specifications are subject Programmable to change without notice Function Keys For Technical Support. 6860 FEATURES call 800-446-6444 PHYSICAL ORDERING INFORMATION Flush Mount 6860:Pei-note Annunciator Four line(4x40)LCD Outside wall:12.25"W x 11,5"H x 7/8"D(31.1W x annunciator.Red 29.2H x 2.2D cm) Inside wall:9-3/8"W x 8-3/8"H x 2"D(23,8W x ACCESSORIES 21.3H x 5 1D crn) RA-100TR:Red surface mounttrim ring Surface Mount:(Including Trim Ring)12.25"W x 11.5"H x 3"D(31.1W x 29.2H x 2.2D cm) AGENCY LISTINGS AND APPROVALS UL listed ENVIRONMENTAL CSFM#7165-0559:0500 Operating Temperature:320F to 120°F (0°C to NFPA 72 490C) FM approved Humidity:0 to 93%relative humidity(non- FDNY COA approved condensing) ELECTRICAL Operating Voltage:24VDC Standby Current:25nnA Alarm Current:50i-nA For more information Learn more about Silent Knight's 6860 and other products available by visiting www.SitentKnight.com Honeywell Silent Knight 12 Clintonville Road Northford,CT 06472-1610 Honeywell 800,328 0103 3516121 Al 11/17 SILENT' www.11oneywell.com '.5 2017 Honeywell International Inc U XNIGHT f f Honeywell SILENT SK-PHOTO-W Series Intelligent Plug-In Photoelectric Smoke Detector Honeywell Silent Knight SK-PHOTO-W Series plug-in smoke detectors are designed for both performance and aesthetics.Anew modern,sleek, contemporary design and enhanced opticalsensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software.Sensitivity is continuously monitored and reported to the panel.Point ID capability allows each detector's address to be set 1 with rotary,decimal address switches,providing exactdetector location for selective maintenance when chamber contamination reaches an _ unacceptable level. - Dual electronic thermistors add 135°F(57"C)fixed temperature thermal sensing on the SK-PHOTO-T-W.The SK-PHOTO-R-W is a remote test SK-PHOTO-W capable detector for use with DNR Series duct detector housings. • New modern profile for • Dual LED design Expanded color Optional relay, improved aesthetics provides 3601 viewing options isolator,and sounder • Stable communication angle SEMS screws for bases technique with noise • Remote test feature wiring of the separate Plugs into separate immunity from the panel base base for ease of • Low standby current • Built-in functional test installation and ' • Two-wire SLC switch activated by maintenance connection external magnet • Optional remote, • Built-in tamper- single-gang LED resistant feature accessory • Sealed against back pressure ti DETECTOR SPACING AND INTELLIGENT BASES ACCESSORIES APPLICATIONS B300-6:White,standard flanged CK300:Color Kit(includes cover and Honeywell recommends spacing low-profile mounting base. trim ring),white, 10-Pack. detectors in compliance with NFPA 72. B300-6-BP:Bulk pack of B300-6, CK300-IV: Color Kit(includes cover In low airflow applications with smooth package contains 10. and trim ring),ivory, LO-Pack. ceiling,space detectors 30 feet(9m). B300-6-IV:Ivory,standard flanged CK300-BL:Color Kit(includes cover For specific information regarding low-profile mounting base. and trim ring),black,10-Pack. detector spacing, placement,and 6501-WHITE:White,standard M02-04-01:Detector test magnet. special applications refer to NFPA 72, European flangeless mounting base.UL M02-09-00:Telescoping test magnet. System Smoke Detector Application listed. RA10OZ:Remote LED annunciator Guide,document A05-1003:is available at systemsensor.com B501-BL:Black,standard European SMB600:Surface Mounting Kit flangeless mounting base. UL listed. (flanged). INSTALLATION B501-IV:Ivory,standard European TR300:Replacementtrim ring for flangeless mounting base.UL listed. B300-6,white,The SK-PHOTO-W Series plug-in detectors use a separate base to B20OS-WH:White,Intelligent, TR300-IV:Replacement trim ring for simplify installation,service,and programmable sounder base. B300 o-IV,ivory, maintenance.Installation instructions B20OS-IV:Ivory, Intelligent, are shipped with each detector. programmable sounder base, B200SR-WH:White, Intelligent sounder Mount base(all base types)on an base for retrofit applications. electrical backbox which is at least 1.5" B200SR-IV:Ivory, Intelligent sounder (3,81 cm)deep. base For retrofit applications. NOTE: 620OS-LF-WH:White, Low Frequency • Because of the inherent supervision Intelligent,programmable sounder base. provided by the SLC loop,end-of-line resistors are not required.Wiring B20OS-LF-IV:Ivory,Low Frequency "T-taps"or branches are permitted for Intelligent,programmable sounder Style 4(Class 'B")wiring. base. B200SR-LF-WH:White. Low •When using relay or sounder bases, Frequency Intelligent sounder base for consult the installation sheet for device retrofit applications. limitations between isolator modules B200SR-LF-IV:Ivory,Low Frequency and isolator bases. Intelligent sounder base for retrofit applications. ORDERING INFORMATION B224RB-WH:White,plug-in System SK-PHOTO-W:Photoelectric smoke Sensor relay base. detector,white. B224RB-IV:Ivory, plug-in System SK-PHOTO-R-W:Photoelectric smoke Sensor relay base. detector.remote test capable,for use B224BI-WH:White,plug-in System with DNR(W)duct smoke detectors, Sensor isolator detector base. white. B224BI-IV:Ivory,plug-in System SK-PHOTO-T-W:Photoelectric smoke Sensor isolator detector base, detector with thermal sensing,white. SK--PHOTO-W Series Detector Technical Specifications PHYSICAL COMPATIBILITY For a complete listing of all compliance approvals and Height:2.0"(51mm)installed in B300-6 base The SK-PHOTO-W series detectors are certificat,ons_pie�asevisit Diameter:6 2"(156mm)installed in B300-6 compatible with the following Honeywell Silent www-silentknight-com base 4.1"(104 mm)installed in B501 base Knight fire alarm control panels: Mlcrosoft Windows,and the Windows Logo are Weight:3 4 oz(95 g) 6820:Addressable fire alarm control panel egistered trademarks 6820EVS:Addressable fire alarm control panel or trademarks of ENVIRONMENTAL klicrosoft Col poi abon with an emergency voice system Operating Temperature range: silent Knight,System 6808:Addressable fire alarm control panel Sensor and Honeywell- Photo:32°F to 122'F(0°C to 50°C) are registered 6700:Addressable fire alanr control panel trademarks of I-ioneyweil Photo with Thermal:32°F to 1000F(0°C to International,Inc 38°C) 5700:Addressable fire alarm control panel 5808:Addressable fire alarm control panel This document is not intended to be used for UL listed Velocity range:Photo/Photo with 5820XL:Addressable fire alarm control panel installation pur poses We Thenna[i 0 to 4,000 fpm(0 to 20 m/sec) tryto keep our product (suitable for installation in ducts) 5820XL-EVS:Addressable fire alarm control information up-to 0 o panel with an emergency voice system date and accurate.We Humidity:10 /o to 93 /o non-condensing cannot cover all specific applications oranbcipate Thermal Ratings: Fixed Temperature Set point: AGENCY LISTINGS AND APPROVALS all requirements.All 1350F(57c'C) For exact certification listings for each model, specifications are subject please reference the respective agency Web site. to change without notice ELECTRICAL RATINGS UL listed:S6173 Far Technical Suppoi t, Voltage Range:15 to 32VDC peak FM approved call 800-446-6444 CSFM:7272-0559:0523 Operating Current(.,?24VDC:200µA(one communication every 5 seconds with green LED blink on communication) Maximum Current:4.5mA is 24VDC(one communication every 5 seconds with amber LED solid on). For more information Learn more about Honeywell Silent Knight and other products by visiting wwwsilentknightcom Honeywell Silent Knight 12 Clintonville Road Honeywell N o rthfo rd,CT 06472 Doc 3516341 Rev A 104/18 SILENT' 800-328-0103 2018 Honeywell International Inc KMCK HT Honeywell ®SILENT' I HGWT SK-HEAT-W Series Intelligent Thermal (Heat) Detector Honeywell Silent Knight SK-H EAT-W Series intelligent thermal detectors are designed for both performance and aesthetics A new modern,sleek, contemporary design and advanced thermal technologies make the SK-HEAT-W Series ideal for both system operation and building design. The point ID address,set using rotary decimal switches.provide specific detector locations.The series includes a 135°F/57°C fixed temperature. �l rate-of-rise and a 190°F/88°C fixed high-temperature detectors.These thermal detectors provide effective,intelligent property protection in a variety of applications. SK-HEAT-W • Sleek and stylish • High temperature 360'-field viewing Built-in functional test Sealed against back contemporary design model(SK-HEAT- angle of the visual switch activated by pressure • Advanced thermal W-HT)factory preset alarm indicators(two external magnet • Plugs into separate technologyfor fast to 190'F(88'C) bi-color LEDs)_LEDs Walk test with address base for ease of response • Addressable by device blink green in Normal display(an address of installation and condition and turn on 121 will blink the maintenance • Fixed temperature • Two-wire.SLC steady red in Alarm detector LED 12- model(SK-HEAT-W) connection • SEMS screws for factor preset Integral (pause)-1) y p • Visible LEDs"blink" wiring of the separate 135'F(57'C) communications and Low standby current base every time the unit is built-in device-type • Rate-of-rise model addressed identification Designed for • Optional remote. (SK-HEAT-W-ROR), directsurfaceor single-gang LED • Built-in tamper- • Remote test feature 15'F(8.3'C)per resistant feature electrical box accessory minute from the panel mounting :� I I APPLICATIONS INTELLIGENT BASES ACCESSORIES Use thermal detectors for protection of B300-6:White,standard flanged CK300:Color Kit(includes- cover and property.For further information, refer low-profile mounting base. trim ring),white, 10-Pack, to manual 156-6541,Applications B300-6-BP: Bulk pack of B300-6 CK300-IV: Color Kit(includes cover Manual for System Smoke Detectors, package contains 10, and trim ring),ivory, 10-Pack, which provides detailed information on B300-6-IV:Ivory,standard flanged CK300-BL:Color Kit(includes cover detector spacing,placement,Zoning, low-profile mounting base. and trim ring),black,10-Pack. wiring,and special applications 6300A-6-IV:Ivory,standard flanged M02-04-01:Detector test magnet. INSTALLATION low-profile mounting base.UL listed. M02-09-00:Telescoping test magnet. B501-WHITE:White,standard RA100Z:Remote LED annunciator The SK-HEAT-W Series plug-in Intelligent thermal detectors use a European flangeless mounting base.UL SMB600:Surface Mounting Kit (flanged). separate base to simplify installation, listed. (flan g service,and maintenance.Installation B501-BL:Black,standard European TR300:Replacement trim ring for instructions are shipped with each flangeless mounting base.UL listed. B300-6,white, detector B501-IV:Ivory,standard European TR300-IV:Replacement trimring for flangeless mounting base.UL listed. B300-6-IV,ivory„ Mount base(all base types)on an B200S-WH:White, Intelligent, electrical backbox which is at least 1.5' programmable sounder base. (3.81 cm)deep. B200S-IV:Ivory,Intelligent, programmable sounder base, NOTE: B200SR-WH:White,Intelligent sounder •Because of the inherent supervision base for retrofit applications. provided by the SLC loop,end-of-line B200SR-IV:Ivory,Intelligent sounder resistors are not required.Wiring base for retrofit applications_ 'T-taps"or branches are permitted for Style 4(Class"B")wiring, B200S-LF-WH:White, Low Frequency Intelligent,programmable sounder •When using relay or sounder bases, base, consult the installation sheet for device B200S-LF-IV:Ivory, Low Frequency limitations between isolator modules Intelligent,programmable sounder and isolator bases. base. NOTE:Detectors must be mounted to one B200SR-LF-WH:White,Low of the Intelligent Bases listed below, Frequency Intelligent sounder base for ORDERING INFORMATION retrofit applications. SK-H EAT-W:Thermal heat detector, B200SR-LF-IV:Ivory,Low Frequency 135°F fixed,white. Intelligent sounder base for retrofit SK-HEAT-ROR-W:Thermal heat applications. detector,135°F rate of rise,white. B224RB-WH:White,plug-in System SK-HEAT-HT-W:Thermal heat detector. Sensor relay base. 190°F high temp,white_ B224RB-IV:Ivory,plug-in System Sensor relay base. B224BI-WH:White,plug-in System Sensor isolator detector base. B224BI-IV:Ivory,plug-in System Sensor isolator detector base. SK-I­-+:FAT-W Series Detector T echnical SpebficaUcins PHYSICAL COMPATIBILITY Fora complete listing of all compliance approvals and Height:2 0"(51mm)installed in B300-6 base The SK-HEAT-W series detectors are Bert fications.Dieose visit Diameter:6.2"(156)-nm)installed in B300-6 compatible with the following Honeywell Silent wwwsilentknight.com base 4 V(10/1 mm)installed in B501 base Knight fire alarm control panels: Microsoft vJindows,and the Windows Logo a,e Weight:3 4 oz(95 g) 6820:Addressable fire alarm control panel registered tradomarks 6820EVS:Addressable fire alarm control panel or tiademarks of ENVIRONMENTAL Microsoft Corporation with an emergency voice system Operating Temperature range: silent Knight ,system 6808:Addressable fire alarm control panel Sensor and Honeywell` Heat-Fixed temperature:-4°F to 100°F(-20°C at e registered to 38°C) 6700:Addressable fire alarm control panel tl3demarks of Honeywell 5700:Addressable fire alarm control panel International,Inc Heat-Rate of Rise(ROR):-4°F to 100°F(-20°C This document is not to 38°C) 5808:Addressable fire alarm control panel mended to be used fat ° ° ° 5820XL:Addressable fire alarm control panel nstallation purposes.We Heat-High Temperature:-4 F to 150 F(-20 y to keep our product to 66°C) 5820XL-EVS:Addressable fire alarm control information up-to 0 o panel with an emergency voice system date and accurate.We Humidity:10 /o to 93 /o non-condensing cannot cover all specific applications or anticipate Thermal Ratings: Fixed Temperature Set point: AGENCY LISTINGS AND APPROVALS all requirements All 135°F(57°C) For exact certification listings for each model, specifications are subject please reference the respective agency Web site_ to change without notice. Rate-of-Rise Detection:15°F/min.(8.3°C/min UL listed:52101 Fat TechnicalSupport, High Temperature Heat:190°F(88°C)Electrical FM Approved call 800-446-6444 Ratings CSFM:7270-0559:0511 ELECTRICAL RATINGS Voltage Range:15 to 32VDC peak Standby current(max.avg.):200uA ca 24 VDC (one communication every 5 seconds with LED enabled). LED current(max.):4 5mA ,24 VDC("ON"). For more information Learn more about Honeywell Silent Knight and other products by visiting wwwsilentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell N o rth fo rd,CT 06472 Doc 351637 1 Rev A 104/18 SILENT 800-328-0103 m 201S Honeywell International Inc Klmci"T Honeywell STLENT' E N]Gf r SK-MINIMON Intelligent Mini Monitor Module The SK-MINIMON is an addressable monitor modules for use with the Honeywell Silent Knight fire alarm control panels(FACPs)-The SK- MINIMON acts as an interface to contact devices,such as waterflow switches and pull p supports Class B supervised wiring to the load device.Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions The SK-MINIMON can be mounted in a single gangjunction box directly behind the monitored device.Its small size and lightweight allow itto be installed without rigid mounting requirements INSTALLATION SK-MINIMON The SK-MINIMON can be mounted in a single gangjunction box directly behind the monitored device.Its small size and lightweight allow itto be installed without rigid mounting requirements. i= EA T U R E S BENEFIT `, • Single c-DnIact monitor • Rotary_address • SK-Minimon support switches for fast For Class B(Style B) installation contact monitor wiring • UL Listed • Small and lightweight • CSFM Listed size allows for flexible . FM Approved mountiny options 1 6 C• r� SK-MINIMON Technical Specifications Foi a complete listing of all compliance approvals and certifications please visit PHYSICAL ORDERING INFORMATION www.silentknight.com Dimensions:2-75"W x 1 3"H x0 5"D SK-MINIMON:Mini monitoring module Microsoft Windows and Weight:12 oz(37 g) the Windows Logo are COMPATIBILITY registered trademarks ELECTRICAL The SK-MINIMON is compatible with the or tl adernal ks of Operating Voltage:15-32VDC following Honeywell Silent Knight fire alarm Microsoft Corpoi ation SLC Standby and Alarm Current:350 µA control panels: Silent Knight ,System End-of-Line Resistance:47KQ 6820:Addressable fire alarm control panel Sensor and Honeywell` Initiating device circuit wiring resistance:1,500Q 6820EVS:Addressable fire alarm control panel are registered max with an emergency voice system tl ademarks of Honeywell 6808:Addressable fire alarm control panel International,Inc SLC loop resistance:4052 max Wire Length:6"min 6700:Addressable fire alarm control panel This document is not 5700:Addressable fire alarm control panel intended to he used for ENVIRONMENTAL 5808:Addressable fire alarm control panel nstallation purposes.We tryta keep out product Operating Temperature:32EF-120a(0M- 5820XL:Addressable fire alarm control panel information up-to 49M) 5820XL-EVS:Addressable fire alarm control panel date and accurate.We Humidity:10%-93%non-condensing with an emergency voice system cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice For Technical Support, call 800-446-6444 For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknlght.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 Doc 3501331 Rev G 111/17 SILENT' 800-328-0103 C 2017 Honeywell International Inc_ ®KMC..M Honeywell LSILENT' cw GM SK-R LAY Intelligent Relay Module The SK-RE LAY is an addressable relay mod LAG foruseW h Honeywell Silent Knight Series fire alarm control panels(FACPs) The SK-RELAY allows a Silent Knight FACP to switch discrete contacts by code command.The relay contains two isolated sets of Form C contacts,which operate as a DPDT switch.No supervision is provided for the notification aooliance circuit, Honeywell till E\T The SK-RELAY contacts can be used for virtually any normally open or normally closed application.Each SK-RELAY is programmed with a unique signaling line circuit(SLC)loop address.When an event occurs that controls the SK-RELAY,the relay is triggered bythe FACP + INSTALLATION The SK-RELAY mounts directly into a 4"square electrical box,The box must SK-RELAY have a minimum depth of 2-1/8".A surface mount electrical box(System Sensor"PN SMB500)is available from Silent Knight • Two sets of Form C • Panel controlled Polling LED visible contacts status LED that through the cover • Rotary address flashes green in plate switches for fast normal state and is SEMS screws for easy installation solid red in alarm wiring •• Contacts are rated for Relay programming is completely flexible- UL Listed a variety of amps(see can be mapped to Specifications) zone conditions ' - .� 1 SK-RELAY Technical Specifications Foi a complete listing of all compliance approvals and certifications please visit PHYSICAL ORDERING INFORMATION www.sitentknight.com 4,675"H x 4 275"W x 1.4"D SK-RELAY:Relay Module Shipping Weight:6 3 oz(196 g) Microsoft Nimdows,and ACCESSORIES the Windows Logo ai e registered trademarks ELECTRICAL SMB500:4"Square Surface Mount Electrical Box ortiademarks of Operating Voltage:15—32 VDC C13500:Module Barrier Microsoft Corporation End-of-Line Resistance:Not used SLC Standby&Alarm Current: 255mA max rai COMPATIBILITY Silent Knight System Sensor and Honeywell' 24VDC(one communication every 5 sec with LED The SK-RELAY is compatible with the following are registered enabled) Honeywell Silent Knight fire alarm control panels: tt ademarks of Honeywell 6820:Addressable fire alarm control panel International,Inc ENVIRONMENTAL 6820EVS:Addressable fire alarm control panel This document is not Operating Temperature:321ff—1201L(0M— with an emergency mass notification system. intended to be used for 49T) installation purposes We 6808:Addressable fire alarm control panel Humidity:10%—93%ron-condensing try to keep our product 6700:Addressable fire alarm control panel information up-to RELAY CONTACT RATINGS 5700:Addressable fire alarm control panel date and accurate.We 5808:Addressable fire alarm control panel cannot cover all specific 3.0A a 30VDC resistive applications oranticipate 0.9A,�11OVDC resistive 5820XL:Addressable fire alarm control panel all requirements.All 0.9A ca)125VAC resistive 5820XL-EVS:Addressable fire alarm control panel specifications are subject 0,5A,a,125VAC inductive(PF=.35) with an emergency mass notification system. to change without notice 0.7A,_;(,75VAC inductive(PF= 35) Foi Technical Support. ca11800-446-6444 For more information Learn more about Honeywell Silent Knight and other products by visiting www.s i le ntkn i g ht.co m Honeywell Silent Knight Honeywell 12 Clintonville Road Northford,CT 06472 Doc 3501271 Rev GI 11/17 SILEW' 800-328-0103 CC 2017 Honeywell International Inc, O KMIGHT �� 4 I 1 Honeywell SILENT' RMCHT SK-PULL-SA / SK-PULL-DA Intelligent Pull Stations The SK-PULL-SA is a single action pull station requiring only one motion to . activate the station The SK-PULL-DA is a dual action pull station requiring two motions to active the station.The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel(FACP). PULL DOWN Extremely easy to operate,the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating a fire alarm signal.The FACP recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. t � INSTALLATION The SK-PULL-SA and SK-PULLDA can be surface mounted to an SB-1/0 SK-PULL-SA surface back box or semi--flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm)or double gang or4"(10.61 cm)square electrical box You can also use the optional(System Sensor"PN BG-TR) trim ring if the station is being semi-flush mounted, PUSH IN SK-PULL-DA • .nstail can open • Key on r3;ed test and ?Feels the An?@ ri::an5 • eI ab!e a n a t cg E i n to is.�: d t. station without reset lock using lock m0h.Disabilities Act communications for clown posi`lor.and trip causing an alarm plate acti'lator Accessibility trouble-tree ooer,9uon word Activated condiljon matches Key Guidelirnes CADAA.S,) • Braille e,cton sLstationappears;clearly . controls and operating indreating the sra"un • ❑pal-color L,ED is compatible FACT handle visible th+'ough her;dta Locks mechanisms has been pullad guidelines?Seclion • Rotary address o;station blinks green ° UL Listed,including • Meets ADA 4_L3r13]) switches For fast to inr-licate rnormal requi UL 38.Standard ref rerneni far 5 lbs installation opef etion and remains Shell,door,and handle �Aa�7i.iall Actuated max!n�ium pull force to Y steariy red in a?ctded ''r'om dui ab!e Signaling Sysr,r>.„ act�w_ ca,:±Rion _ X A N I l' SK-PULL SA / SK-PULL DA Technical Specifications Fora complete listing of all compliance approvals and certifications.please visit PHYSICAL ORDERING INFORMATION www.silentknight.com Dimensions:5 5" H x 4"W x 1 45"D(14 x 10 2 x SK-Pull-SA:Single Action Pull Station 3.7cm) fl�licrosofLVdir.dows and SK-Pull-DA:Dual Action Pull Station the windows Logo are Housing Material:LEXAN polycarbonate resin registered trademarks Bi-Colored LED: ACCESSORIES or ti adernarks of Blinking Green:Normal BG-TR:Optional trim ring. \,licrosoft Cot poi aron Steady Red:Alarm SB-1/0:Surface backbox,indoor/outdoor. Silent Knight ,System Switch:Single pole,single throw(SPST)normally 'Unless otherwise noted,specifications apply to Sensor and Honeywell" open(N/0)switch which closes upon activation of SK-Pull-SA and SK-Pull-DA are registered the pull station ti ademarks of Honeywell COMPATIBILITY International,Inc ELECTRICAL The SK-PULL-SA AND SK-PULL-DA are This document is not Operating Voltage:15-32VDC compatible with the following Honeywell Silent intended to be used for SLC Standby and Alarm Current:350µA Knight fire alarm control panels: installation put poses.We 6820:Addressable fire alarm control panel tryto keep our product Wire Gauge:Up to 12AWG(3.1 mm ) p information up-to 6820EVS:Addressable fire alarm control panel date and accurate.We ENVIRONMENTAL with an emergency voice system. cannot cover all specific Operating Temperature:3214F-120a(01M- 6808:Addressable fire alarm control panel applications or anticipate 490:) 6700:Addressable fire alarm control panel all requirements.All specifications are subject Humidity:10%-93%non-condensing 5700:Addressable fire alarm control panel to change without notice 5808:Addressable fire alarm control panel Foi Technical Support, 5820XL:Addressable fire alarm control panel ca11800 446 6444 5820XL-EVS:Addressable fire alarm control panel with an emergency voice system For more information Learn more about Honeywell Silent Knight and other products byvisiting wwwsilentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 Doc 3501351 Rev F 1 11117 SILEW' 800-328-0103 (c:2017 Honeywell International Inc KM«HT J Honeywell I Fire Alarm Communicators SILENT'©KNIGHT CELL-CAB-SK and CELL-MOD Cellular Fire Alarm Communicators The CELL-CAB-SK and CELL-MOD are cellular communicator options for the Honeywell Silent Knight 6000 Series addressable fire alarm control panels(FACPs). These GSM communicators provide cellular communication as an alternate method of central station reporting.Combined with the FACP's onboard communicator,they provide dual path cellular and IP reporting capability,while eliminating the need and cost of separate dialer capture modules and special programming.Battery backup from the control panel maximizes overall system efficiency. LJIL Small size,easy to install,with a programmable supervision time of 1-60 minutes, CELL-MOD these communicators can be positioned remotelyfrom the fire alarm control panel via 4-wire serial bus for optimum reception.The CELL-CAB-SK and CELL-MOD are ILL 864 and NFPA 72 fire code compliant for sole,primary,and backup communications.They work with AlarmNet°to provide a UL-listed connection to the central station. The CELL-CAB-SK includes a GSM communicator within a metal cabinet enclosure with lock and key and includes an external antenna.The CELL-MOD houses the GSM communicator in a plastic enclosure and has an option for an external antenna. CELL-CAB-SK FENFU RES & BEN EFIT- • Communicate directly Battery backup • UL 864 and NFPA 72 • Remote mounting up • Programmable with Silent Knight 6000 provided by the panel code compliant for to 6,000 ft(1,828.8 m) supervision time from Series fire alarm to increase system sole,primary.and 1-60 minutes control panels efficiency and decrease backup • Quality of Service cost communications (QOS)diagnostics via • Provide full data • Easy installation-no AlarmNet convey vital reporting using need for special Provide dual-path Easity managed communicator Contact ID format programming or cellular and IP accounts through information such as separate dialer module reporting capability on-line management when messages are tools received,signal strength,and message path used f � v 7 9 / CELL-CAB-SK and CELL-MOD Technical Specifications PHYSICAL COMPATIBILITY AlarmNet',Honeywell",and Silent Knight'are registered CELL-MOD:1.809"W x 5.982"H x 1.5"D The CELL-CAB-SK and CELL-MOD are compatible with trademarks of Honeywell (19,83cm x 15.19cm x 3.81cm) the following Honeywell Silent Knight FACPs: International,Inc_ CELL-CAB-SK:10.38"W x 10.165"H x 3.176"D 6820: addressable FACP with up to 1,110 points This document is not intended (26.37cm x 25.82 cm x 8.07cm) 6820EVS: addressable fire alarm control panel with up to be used for installation SHIPPING WEIGHT to 1.110 points and an emergency mass notification purposes We try to keep our system product information up-to- CELL-MOD:1.3 lbs(589.7 g) 6808:addressable FACP with up to 198 points date and accurate.We cannot CELL-CAB-SK:5 2 lbs(2.36 Kg) 6700:addressable FACP with up to 100 points cover all specific applications or anticipate all requirements ENVIRONMENTAL ORDERING INFORMATION Allspecifications aresubjectto Operating Temperature:32°F-120°F(0°C-49°C) change without notice. CELL-CAB-SK: Cellular module housed in a red,metal Humidity:10-93%relative humidity(non-condensing) cabinet with lock and key.Includes external antenna ELECTRICAL CELL-MOD:Cellular module housed in a red,plastic Standby Current:55mA enclosure.(External antenna sold separately) CELL-ANTENNA:3dB gain external/remote antenna Alarm Current:100mA 7626-50HC:50 ft.(15.24 m)antenna cable,low loss RADIO TRANSCEIVER APPROVALS 3G Cellular Radio U L-Listed UMTS WCDMA FDD 850/190OMHz CSFM Approved FCC part 15,22,24,and 68 compliant FCC I D:CFS8DLPHS8-US COMMUNICATION PROTOCOLS HSPA+(4G)and HSPA(HSDPA&HSUPA)(3G) Honeywell Silent Knight 12 Clintonville Road Northford,CT 06472-1610 Honeywell 203 484,7161 351627 1 B 1 08/18 SILENT' www.sitentknight.com ,e 2018 Honeywell International Inc WGHT SYS TEM SENSOR F F Indoor Selectable- 1�1�w, , R Output Horns, { {r.►, ' E Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut . '� ♦ r}' , rR installation times and maximize profits with lower t current draw and modern aesthetics. Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns, strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices,and plain, FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns, strobes, and horn strobes 15,30, 75,95, 110, 135,and 185 include a variety of features that increase their application versatility • Horn rated at 88+dBA at 16 volts while simplifying installation.All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage, the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring, so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch Agency Listings for horn tones with two volume selections. SIGNAUNG UL F M (Aw LISTED APPROVED S5512 FM approved except 7125-16530504 S401 I for ALERT models 7135-16530503 3057383,3057072 AVD5665-05-2122/2018-Page I �r L-Series Specifications Arch itect/En gin eer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 17/6-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 1 7/a-inch back box A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models_The notification appliance circuit wiring shall terminate at the universal mounting plate.Also, L-Series products,when used with the Sync•Circuit'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75.95, 110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411h6 x 411/16 x 21/a-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physleal/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 1.91-D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6-L x 4XV x 1.25-D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. 1 AVD5665-05•212212018•Page 2 UL Current Draw Data 'UL Max.Horn Current Draw(rnA RMS) UL Max.Strobe Current Draw(mA RMS) 1 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe,Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3,11K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1 K Non-Temporal High 104 131 177 204 230 264 326 3.1 K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data StrobeHorn and Horn Output B-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9' Coded High 85 90 90 10` 3.1 KHz Coded High 84 89 89 'Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on, AVD5865-05•212212018•Page 3 L-Series Dimensions _• ._ 1.91" _. 346" _ — 346' _ 48,5 mm 88 mm _. — 1.25' — 3.57" tw 88 mm —• — 1.25" 32 mm 32 mm (9.1 cm)• �(3.9 cm) 0 0 00°°�0�0°0 0°0 �•' 1I 5.27' •°i!,�,�J°• a°040°0 0 4 " IL•--, �)I 133.9 mm 5.27' Opeo0o4�oQo (13.75,38 cm) �:�' /•� 133.9 mm \- eeo°o o°o°°°°°°°° O° \ � _000000 t o 0 A0548-00 A0547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL 4.70" (11.94cm) 1.9V _ 4.7"(4.85 cm) —- 119 mm � 1.25" 4'B2• 32 mm (12.24 cm) 1.25" 1 (4.69 cm) (3.18 mm) lP 5.67" �° o, 5.67" °ee°° 578.. 1 0I 144 mm oe,e°°,o°0 14.68 cm) 39 (14.4 cm) °01°1°1°7°0 - 0�0444�0 �1 I A0.950-0i1 A0549-00 A0554-01 Strobe,Horn Strobe Horn Wall Surface Mount Back Box SBBRUSBBWL L-Series Ordering Information ModelDescription Wall Horn Strobes Horns" P2RL 2-Wire,Horn Strobe,Red HRL" Horn.Red P2WL 2-Wire,Horn Strobe,White HWL' Horn,White P2GRL 2-Wire,Compact Horn Strobe, Red HGRL` Compact Horn, Red P2GWL 2-Wire,Comp 2 fils act Horn Strobe,White HGWL' Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBWL Wall Surface Mount Back Box, Red P4RL 4-Wire, Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire, Horn Strobe,White SBBGWL Compact Wall Surface Mount Back Box, Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe,Red SWL Strobe,White SGRL Compact Strobe, Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover). All-SP models have"FUEGO"marking on cover. All-ALERT models have"ALERT"marking on cover. `Horn-only models are listed for wall or ceiling use. SYSTEM 3825 Ohio Avenue•St. Charles, IL 60174 ©2018SyslemSo—,. SENSOR Phone:800-SENSOR2•Fax: 630-377-6495 Pro: ctspeciiicatons subject to change wl!n 1-tic.Visrtsyslemsensorcom for current product nfurma?on,including the latest version al this data s—t www.syste ms enso r.com AVDS665-05.2122120 1 B ��� SYSTEM �4 SENSOR Indoor Selectable= Output Strobes and Horn Strobes for == Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options, System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement_ at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150, and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring, installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings sIcxauxc UcICD APPROVED h 55512 FM approved ecepl 7125-16530504 S401I forALERT—dels 7135.16530503 30573B3 AVDS668--02•1 210 112017•Page 3 J r L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also. L-Series products,when used with the Sync•Circuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150.and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR' Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. I AVDS868-02•12/01/2017•P3ge 9 C t UL Current Draw Data UL Max.Strobe Current Draw(rnA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High ill 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data StrobeHorn 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS866-02•121"12017•Page 3 C L-Series Dimensions 2.47"(62.7 mm) — - 1.37"(34.3 mm) — — - 6 92"diam. _. 2.5' 6(173 mm) \ 1 (175 77 mm) (64 mm) I O r O TR O o CD o O O op A0545-00 A054fi-OD Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box 0 O _ p I, �1001411e 1 O „ O A0494-01 A0631-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information ModelDescription Ceiling Horn Strobes Ceiling_Strobes PC2RL 2-Wire, Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". t msen SYSTEM �z� s�a�em Sensor 3825 Ohio ` Avenue•St.Charles, IL 60174 Product speeifi.at�ons subject to change witneutnolier,Vn Ysfeso'com SENSOR Phone:800-SENSOR2•Fax:630-377-6495 for cu^art product m'ormatlo,i,including fne latest version of tnis data sheet AVD5368-02•1 210 1/20 1 7 f fi. SYSTEM SENSOR Selectable-Output Low Frequency Sounder and Low = —_ Frequency Sounder i R Strobes for Wall E E Applications e SpectrAlert°Advance audible visible notification products SPECTRAlert E are rich with features guaranteed to cut installation times and maximize profits. Features The SpectrAlert Advance series offers the most versatile • 520 Hz± 10%square wave tone and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry.With white and red plastic housings, • Plug-in design with minimal intrusion into the back box dual listed for wall and ceiling mounting, SpectrAlert Advance can • Tamper-resistant construction meet virtually any application requirement. • Field-selectable candela settings on wall units: The wall-mount low frequency sounder,and low frequency sounder 135, 150, 177,and 185 strobes were designed to address the NFPA 72 sleeping space • Rotary switch for low frequency sounder tone requirements that require a low frequency notification appliance that • Universal mounting plate for wall units operates within frequency range of 520 Hz± 10%and is of a square • Mounting plate shorting spring checks wiring continuity before wave tone. Like the entire SpectrAlert Advance product line they device installation include a variety of features that increase their application versatility while simplifying installation.All devices feature plug-in designs • Electrically compatible with legacy SpectrAlert devices with minimal intrusion into the back box,making installations fast • Compatible with MDL3 sync module and foolproof while virtually eliminating costly and time-consuming • Listed for ceiling or wall mounting ground faults. To further simplify installation and protect devices from construction damage,SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, Agency Listings automatic selection of 12-or 24-volt operation, and a rotary switch for 520 Hz low frequency sounder tones, SIGNALING -- U� FM LISTED AMlaoven approved SUII(s-der) 3047563 MEA452-Os-E 7135-1653:9223 55512(sv°bes) 7125-1653 0224 �! r SpectrAlert Advance Specifications Arch itect/Engi neer Specifications General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 1%-inch back box, 4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts_When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Low Frequency Sounder strobes shall have field-selectable candela settings including 135, 150, 177, and 185.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone and have a permanent marking on the housing that reads"low frequency sounder". Low Frequency Sounder The low frequency sounder shall be a System Sensor SpectrAlert Advance Model listed to UL 464 and shall be approved for fire protective service.The low frequency sounder and the Sync•CircuitTM MDL3 Module accessory,if used,shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts(includes fire alarm panels with built in sync).When used with the Sync•Circuit Module MDL3, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used,then refer to the compatibility listing of the panel to determine maximum devices on a circuit.The low frequency sounder has an option to switch between temporal three pattern,non-temporal(continuous)pattern and coded supply within the frequency range of 520Hz± 10%square wave tone,The low frequency sounder shall operate on a coded or non-coded power supply. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The sounder shall have an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service,The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three.Also,while operating the strobes,the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires.The module shall mount to a 4"A6 x 4"/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Specifications Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Frequency Range 520 Hz± 10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 12 DC/FWR or regulated 24 DC/FWR Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR' Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 6.4 inches L x 4.7 inches W x 2.5 inches D (162 mm L x 119 mm W x 64 mm D) Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 inches D (142 mm L x 119 mm W x 33 mm D) Low Frequency Sounder/Strobe with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D Dimensions(SBBR,SBBW) (162 mm L x 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D (SBBR,SBBW) (145 mm L x 120 mm W x 76 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 4 UL Current Draw Data UL Max.Low Frequency Sounder Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 191 262 138 166 Continuous High 292 384 138 208 Coded High 292 388 153 205 UL Max.Current Draw(mA RMS),2-Wire Low Frequency Sounder Strobe,High Candela Range 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal 277 292 325 344 Temporal 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 Low Frequency Sounder Tones and Sound Output Data StrobeLow Frequency Sounder and Low Frequency Sounder Output 8-17.5 16-33 24-Volt Nominal Volts Volts Reverberant Anechoic Switch Position Sound Pattern DC FWR DC FWR DC FWR DC FWR Temporal 76 76 76 76 76 76 86 86 2 Continuous 80 80 80 80 80 80 90 90 3- Coded 80 80 80 80 80 80 90 90 t Sounder ratings provided are for continuous voltage as provided by the NAC 1 SpectrAlert Advance Dimensions �4.7in.� 2.5in. 4.7 in. — t1.3 in.�i 6.4 in. 1 5.6 in. Wall-mount low frequency sounder strobes Wall-mount low frequency sounder SpectrAlert Advance Ordering Information Model Description Wall Low Frequency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe,High cd,Red P2WH-LF 2-Wire Low Frequency Sounder Strobe,High cd,White Low Frequency Sounders HR-LF Low Frequency Sounder, Red HW-LF Low Frequency Sounder,White Accessories SBBR Surface Mount Back Box,Wall, Red SBBW Surface Mount Back Box,Wall,White TR-HS Trim Ring,Wall, Red Notes: "Heigh cd"refers to strobes that include 135,150,177,and 185 candela settings, SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©1015symemSan— �>>> SENSOR Phone:8C)O SENSOR2•Fax:630-377 6495 Prorc-seprod ct;n(omton,t to cbludinangeg In latest Visit tInisd nslr com eet for c���en�.product�nlormahon,including We latest version�I lnia data aheet www.systemsensor.com AVOS 16404•1/15 Permit#: 2787 Permit Date: 09/12/19 Permit Type: FIRE ALARM Project Name: AMCAL Fire Alarm Applicant Name: AMCAL General Contractors Applicant Address: 30141 Agoura Rd Suite 100 Applicant, City, State, Zip: Agoura Hills,WA 91301 Contact: Mario Turner Phone: 949-863-9408 Email: mario@amcalhousing.com; kconner@abcomllc.com Scope of Work: Fire Alarm Valuation: 190000.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 02/18/2020 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning CITY OF ARL BSP 9418 31052100306900 17309 40TH AVENUE NE REC AFN 201808215006& AMWA CEDAR 110 Senior Citizen AMD BSP REC AFN POINTE FUND LP Exemption Residual 201811065001 Contractors Contractor Primary Contact Phone Address Contractor Type License License# AMWA Construction, 818-706-0694 30141 Agoura CONSTRUCTION Labor&AMWACCI824QG Inc. Road,#100 CONTRACTOR Industries Applied Business 253-335-8551 13029 NE 126th CONSTRUCTION L&I APPLIBC843CS Communications PL CONTRACTOR AMCAL General 30141 Agoura Rd CONSTRUCTION Contractors Mario Turner 949-863-9408 Suite 100 CONTRACTOR Plan Reviews Date Review Type Description Assigned To Review Status 09/12/2019 FIRE ALARM BUILDING Permit and set of approved plans to remain on site during installation.Installers shall present NICET Il certification upon request. 2.Battery load test required,switch system to battery operation 24-hours prior to final inspection.Notification appliances to operate for 5 minutes on battery power. 3,Trouble condition to be verified for initiation, notification and signaling circuits. 4.Manual pull station shall be dual action. 5.Smoke detectors required in hallway outside of elevator #3 on floors 2 and 3(not reflected on drawing or battery calcs). 6.Smoke detector required above RPS#3 per NFPA 72 09/12/2019 FIRE ALARM 10.44. FIRE 7.Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). 8.Record of completion form shall be submitted prior to project close-out. Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the system at project completion.Final approval will not be provided until all conditions are verified.Call at least 48 hours in advance to schedule an inspection. Fees Fee Description Notes Amount Fire Alarm Plan Review Fee $100.00 Fire Sprinkler System Commercial NFPA 13/13R $2,210.96 Processing/Technology $25.00 Credit Card Service $70.08 Total $2,406.04 Attached Letters Date Letter Description 09/12/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 09/19/2019 Eric Casper 77115612 $2,335.96 09/19/2019 Eric Casper Transaction CC Surcharge $70.08 77115612 Outstanding Balance $0.00 Uploaded Files Date File Name 09/27/2021 9771205-2787 IC 8.4.2020.pdf 10/25/2019 5804756-2787 Fire Review Comments.pdf 09/12/2019 5598886-2787 Application.pdf Date: 03/30/2026 Permit#: 2787 Permit 09/12/2019 Date: Review 09/12/2019 Date: Permit FIRE ALARM Type: Review FIRE ALARM Type: Target Date: 09/26/2019 Scheduled 00:00 Time: Completed Date: Description: Permit and set of approved plans to remain on site during installation. Installers shall present NICET Il certification upon request. 2. Battery load test required, switch system to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3, Trouble condition to be verified for initiation, notification and signaling circuits. 4. Manual pull station shall be dual action. 5. Smoke detectors required in hallway outside of elevator#3 on floors 2 and 3 (not reflected on drawing or battery calcs). 6. Smoke detector required above RPS #3 per NFPA 72 10.44. 7. Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). 8. Record of completion form shall be submitted prior to project close-out. Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the system at project completion. Final approval will not be provided until all conditions are verified. Call at least 48 hours in advance to schedule an inspection. Review Status: Assigned FIRE To: Time In: 00:00 Time Out: 00:00 Hours: 0.0 Property Information Parcel#: 31052100306900 AMWA CEDAR POINTE FUND LP AMWA CEDAR POINTE FUND LP 30141 AGOURA RD STE 100 17309 40TH AVENUE NE AGOURA HILLS, CA 91301 Zoning: 110 Senior Citizen Exemption ResidualLot: Mock: Uploaded Files Date File Name Uploaded By 10/25/2019 5804803-2787 Fire Review Comments.pdf Raelynn Jones