Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17522 OSPREY RD_BLD3535_2026
NOTICE V TO PERMITEE AND/OR OWNER Cl PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED DO NOT OCCUPY R(APPROVED PERMIT#: I - S AM M DATE: 11 1-7.z-L?Z.- OB ADDRESS: _ T' j LOT#. PROJECT: TYPE OF INSPECTION: ue oitc OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 Cl CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATA / Cl PLANNING O CIVIL /BUILDING CITY OF ARLINGTON CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 17522 OSPREY RD Permit#:3535 Permit Expiration Date:05/08/2021 Parcel#:00809200001900 Valuation: .00 OWNER APPLICANT CONTRACTOR CARMODY SUSAN E CM Heating CM Heating Inc 17522 OSPREY RD 1415 Broadway 1415 Broadway ARLINGTON,WA 98223 Everett,WA 98201 Everett,WA 98201 425-422-4210 425-259-0550 LIC:CMHEAMH877DN EXP:03/15/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR CM Heating Inc 1415 Broadway Everett,WA 98201 425-259-0550 LIC#: CMHEAMH877DN EXP: 03/15/2021 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. bubble-Saw-rs- Debbie Bauers 11/10/2020 �t �-I� 11/9/2020 Signature Print Name Date eleased Date CONDITIONS Adhere to approved appliance.Approved permit shall be onsite for inspections.Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/09/2020 Inspection Fee $75.00 11/09/2020 Forced Air Heat $15.00 11/09/2020 Mechanical Base $25.00 11/09/2020 Processing/Technology Fee $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon AN. ��` RESIDENTIAL MECHANICAL X PERMIT APPLICATION N l� Department of Community& Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:17522 OSPREY RD Project Description:REPLACE GAS FURNACE Owner: SUE CARMODY Address: 17522 OSPREY RD City: ARLINGTON State.WA Zip Code: 98223 Phone: 425-422-4210 Email:Carmodys7@aol.com Applicant: C.M. HEALING INC Address: 1415 BROADWAY City: EVERETF StateYVA Zip Code: 98201 Phone: 4252590550 Email: debbie@cmheating.com CONTRACTOR INFORMATION Contractor Name:C.M. HEALING INC Address: 1415 BROADWAY City. EVERETT State WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration: 5/3/2021 Phone:4252590550 Email:debbie@cmheating.com STAFF USE O Y Permit#: ' jJJ 'aJ�j�j Accepted by: ,� Date: V ,�`CPiVG� Nov 0 5 2020 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223 • Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES i Furnace (80+) Model #AU D2B060A9V3VB AFUE80% ❑ Heat Pump Model # AFUE_ HSPE AC Unit Model # SEER Freestanding Stove ❑ Fire Place Insert Ij Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance U Other ` Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date: 11/05/2020 Applicant Printed Name: Debbie Bauers hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 70caieaff SAwdaf d AUD213060A9V SPEC-1 B HEATING & AIR CONDITIONING TAG: Upf low/Horizontal Gas Furnace - Variable Speed - 2 Stage Heat AUD2B060A9V3VB 5/811 AUD2B060G9V3VA 6-1/4 A-' 5/8" 1 -5 8" 28-3/8" 1/2 11 5/811 4" DIAMETER FLUE CONNECT 7/8" DIA. HOLES ELECTRICAL CONNECTION �9-5/8" Q 3/4„ O p 7/8" DIA. K.O. 3-15/16" 0 0 0 ~ 2-1/16 ELECTRICAL 8-1/4 � CONNECTION " a a 16 � \ � Q 40„ (ALTERNATE) 0 3-3/4 „ K.O. GAS CONNECTION 2-1/16" I (ALTERNATE) ' I ' 28-1/4" ' I 28-1/4" 23-1 2" / 5-5/16" 3-13/16" 1-1/2" DIA. HOLE �► �3/$" GAS CONNECTION 2-1/8" 0 2013 American Standard Heating&Air Conditioning i *UD2BO6OA9V3VB,*UD2B060G9V3VA FURNACE HEATING AIRFLOW(CFM)AND POWER(WATTS)VS.EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING SW7 SW8 0.1 0.3 0.5 0.7 0.9 CFM 589 604 619 604 607 LOW ON ON TEMP.RISE 49 48 47 48 48 WATTS 65 95 125 160 200 HEATING CFM 663 694 684 681 686 1ST MEDIUM*' ON OFF TEMP.RISE 44 42 42 42 42 STAGE WATTS 75 120 145 185 220 CFM 775 781 776 805 811 HIGH OFF OFF TEMP.RISE 37 37 37 36 36 WATTS 105 145 180 230 270 CFM 813 818 818 837 842 LOW ON ON TEMP.RISE 55 54 54 53 53 WATTS 110 150 185 240 280 HEATING CFM 907 919 942 958 959 2ND MEDIUM** ON OFF TEMP.RISE 49 48 47 46 46 STAGE WATTS 140 200 240 300 330 CFM 1038 1066 1086 1089 1079 HIGH OFF OFF TEMP.RISE 43 42 41 41 41 WATTS 190 260 325 365 415 *UD2BO6OA9V3VB,*UD2BO6OG9V3VA FURNACE COOLING AIRFLOW(CFM)AND POWER(WATTS)VS.EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING (TONS) SWi SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 LOW CFM 499 537 520 520 500 (350 CFM/TON) ON ON OFF ON WATTS 50 80 110 145 175 15 NORMAL ON ON OFF OFF CFM 605 610 610 597 593 (400 CFM/TON) WATTS 60 80 120 155 180 HIGH CFM 649 681 665 665 672 (450C FM/TON) ON ON ON OFF WATTS 75 110 145 180 220 LOW CFM 680 722 680 696 696 (350C FM/TON) OFF ON OFF ON WATTS 80 125 150 190 225 NORMAL OFF ON OFF OFF CFM 798 804 809 823 818 2 (400 CFM/TON) WATTS 105 145 170 235 280 HIGH CFM 884 896 924 931 931 (450 CFM/TON) OFF ON ON OFF WATTS 145 180 240 280 330 LOW CFM 658 863 882 894 895 (350 CFM/TON) ON OFF OFF ON WATTS 125 175 220 275 320 2.5 NORMAL ON OFF OFF OFF CFM 984 1017 1038 1017 1017 (400 CFM/TON) WATTS 170 225 295 330 375 HIGH CFM 1125 1138 1150 1161 1161 (450 CFM/TON) ON OFF ON OFF WATTS 245 315 370 435 475 LOW OFF OFF OFF ON CFM 1035 1056 1076 1076 1076 (350C FM/TON) WATTS 205 265 330 370 430 3** NORMAL** OFF OFF OFF OFF CFM 1208 1247 1268 1278 1200 (400 CFM/TON) WATTS 300 360 440 485 490 HIGH OFF OFF ON OFF CFM 1380 1410 1402 1350 1235 (450 CFM/TON) WATTS 440 500 550 550 525 NOTES: 1.*FIRST LETTER MAY BE"A"OR"T" 2.**FACTORY SETTING. 3.CONTINUOUS FAN SETTING:HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4.LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON:HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. INDOOR BLOWER TIMING COOLING OFF- DELAY OPTIONS Heating: The ECM Fan Control controls the variable speed NOMINAL- indoor blower. The blower"on"time is fixed at 45 seconds after SWITCH SETTINGS SELECTION AIRFLOW ignition. The FAN-OFF period is field selectable by dip switches 5-OFF 6-OFF NONE SAME #2 and#3 on the Integrated Furnace Control at 60, 100, 140, or 180 seconds. The factory setting is 100 seconds, (See unit 5-ON 6-OFF 1.5 MINUTES 100% wiring diagram). Cooling:The fan delay-off period is set by dip switches on the 5-OFF 6-ON 3 MINUTES 50% ECM Fan Control board connected to the Integrated Furnace 5-ON 6-ON 50- 100% Control. The options for cooling delay off is field selectable by dip switches #5 and #6. However, dip switch #1 on the Inte— grated Furnace Control must be set to"ON"for cooling mode to ""-This selection provides ENHANCED MODE,which function properly. is a ramping up and ramping down of the blower speed to The following table and graph explain the delay-off settings: provide improved comfort,quietness,and potential energy savings.See Wiring Diagram notes on the unit or in the Ser- vice Facts for complete wiring setup for ENHANCED MODE. This selection provides a ramping up and ramping down The graph which follows,shows the ramping process. of the blower speed to provide improved comfort,quietness,and potential energy savings. The graph below shows the ramping process. 100%if necessary 80% Dehumidify 50% 50% Fast Coil Cooling Efficiency OFF OFF 1 I 7.5 3 minute minutes minutes General Data o TYPE U flow/Horizontal VENT COLLAR—Size(in.) 4 Round RATINGS2 HEAT EXCHANGER 1 st Stage Input BTUH 39,000 Type-Fired Alum.Steel 1st Stage Capacity BTUH(ICS) 3 31,200 -Unfired 2nd Stage Input BTUH 60,000 Gauge(Fired) 20 2nd Stage Capacity BTUH(ICS) 3 48,000 ORIFICES—Main Temp.rise(Min.-Max.)°F. 30-60 Nat.Gas.Qty.—Drill Size 3—45 BLOWER DRIVE DIRECT L.P Gas Qty.—Drill Size 3—56 Diameter-Width(In.) 10 x 7 AS VALVE Redundant-Two Stage No.Used 1 PILOT SAFETY DEVICE Speeds(No.) VARIABLE SPEED Type Hot Surface Ignition CFM vs.in.w.g. See Fan Performance BURNER —Type Multiport Inshot Motor HP 1/2 Number 3 R.P.M. VARIABLE POWER CONN.—V/Ph/Hz (1) 115/1/60 Volts/Ph/Hz 115/1/60 Ampacity(In Amps) 10.5 FLA 7.7 Max.Overcurrent Protection(amps) 15 COMBUSTION FAN-Type Centrifugal PIPE CONN.SIZE(IN.) 1/2 Drive-No.Speeds Direct-2 DIMENSIONS H x W x D Motor HP-RPM 1/100-2543/1727 Crated(In.) 41-3/4 x 19-1/2 x 30-1/2 Volts/Ph/Hz 115/1/60 Uncrated(In.) 40 x 17-1/2 x 28-1/2 F.L.Amps 0.70/0.40 WEIGHT FILTER—Furnished? Yes Shipping(Lbs.)/Net(Lbs) 136/126 Type Recommended High Velocity Hi Vel.(No.-Size-Thk.)Shipped 1 -17 x 25-1 in. O Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3 O Ratings shown are for elevations up to 2000 feet.For elevations above 2000 feet;Ratings should be reduced at the rate of 4%for each 1000 feet above sea level. O Based on U.S.Government Standard Tests. 0 The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. 1 .� Mechanical Specifications NATURAL GAS MODELS—Central heating BURNERS—Multi-port,in-shotburners will STYLING—Heavy gauge steel and"wrap- furnace designs are certified to ANSI Z21.47 give years of quiet and efficient service. All around" cabinet construction is used in /CSA 2.3 for both natural and L.P.gas. Limit models can be converted to L.P.gas without the cabinet with baked-on enamel finish for setting and rating data were established and changing burners. strength and beauty. The heat exchanger approved under standard rating conditions INTEGR SYSTEM CONTROL—Exclu section of the cabinet is completely lined with ATED using American National Standards Institute INTE deATED operational program provides foil-faced fiberglass insulation. This results standards. sively g in quiet and efficient operation due to the total control of furnace limit sensors,blowers excellent acoustical and insulating qualities SAFE OPERATION—The Integrated Sys- gas valve, flame control and includes self of fiberglass. tem Control has solid state devices, which diagnostics for ease of service. continuously monitor for presence of flame, FEATURES AND GENERAL OPERATION AIR DELIVERY—The variable speed,direct- when the system is in the heating mode of drive blower motor, with sufficient airflow — These High Efficiency Gas Furnaces operation. Dual solenoid combination gas range for most heating and cooling require- employ a Hot Surface Ignition system,which valve and regulator provide extra safety. ments, will switch from heating to cooling eliminates the waste of a constantly burning QUICK HEATING— Durable, cycle tested, speeds on demand from room thermostat. pilot. The integrated system control lights heavy gauge aluminized steel heat ex- The blower door safety switch will prevent or the main burners upon a demand for heat changer quickly transfers heat to provide terminate furnace operation when the blower from the room thermostat. Complete front warm conditioned air to the structure. Low door is removed.(Fan relay and 35VA control service access. energy power vent blower,to increase ef- transformer is standard). a. Low energy power venter. ficiency and provide discharge of gas fumes b. Vent proving differential switch. to the outside, allows common venting with hot water heater. Since American Standard Heating&Air Conditioning has a policy of continuous product and product data improve- Library - ment,it reserves the right to change specifications and Product Section design without notice. Furnaces Product Furnace Technical Literature-Printed in U.S.A. Model AUD2-9V Literature Type Submittal American Standard Sequence Heating&Air Conditioning Date 08/13 6200 Troup Highway C uS Tyler,TX 75707 File No. AUD213O60AW-SPEC-16 www.americanstandardair.com Intertek Supersedes AUD2B060A9V-SPEC-1A �_y Q. RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 17522 OSPREY RD Project Description:REPLACE GAS FURNACE Owner: SUE CARMODY Address: 17522 OSPREY RD City: ARLINGTON State.WA Zip Code: 98223 Phone: 425-422-4210 Email:Carmodys7@aol.com Applicant: C.M. HEATING INC Address. 1415 BROADWAY City. EVERETT StateYVA Zip Code: 98201 Phone. 4252590550 Email. debbie@cmheating.com CONTRACTOR INFORMATION Contractor Name:C.M. HEATING INC Address: 1415 BROADWAY City: EVERETf State WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration: 5/3/2021 Phone: 4252590550 Email:debbie@cmheating.com STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #AUD2B060A9V3VB AFUE80% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances ��eG(CeJo�7G���PiY�� Applicant Signature: tl5a51c3bba4a9294ftlaeB�b41eb Date: 11/05/2020 Applicant Printed Name: Debbie Bauers I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 NOTICE v// TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED El DO NO -}T -OCCUPY peAPPROVED PERMIT#:tF I - Sys AM 1� DATE: ZC72_E JOB ADDRESS: , Z T' =1� LOT#: PROJECT: TYPE OF INSPECTION: � I ue ►J)tCr- OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DAT Cl PLANNING 0 CIVIL BUILDING CITY OF ARLINGTON '�< ' CITY OF ARLINGTON Dw 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 -BUILDING PERMIT 17522 OSPREY RD Permit#:3535 Permit Expiration Date:05/08/2021 Parcel#: 00809200001900 Valuation: .00 OWNER APPLICANT a CONTRACTOR CARMODY SUSAN E CM Heating CM Heating Inc 17522 OSPREY RD 1415 Broadway 1415 Broadway ARLINGTON,WA 98223 Everett,WA 98201 Everett,WA 98201 425-422-4210 425-259-0550 LIC:CMHEAMH877DN EXP:03/15/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR - CM Heating Inc 1415 Broadway Everett,WA 98201 425-259-0550 LIC#: CMHEAMH877DN EXP: 03/15/2021 LIC#: EXP: JOB DESCRIPTION IL r or- PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: RERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. r)&bbre-8au&rsr Debbie Bauers 11/10/2020 11/9/2020 Signature Print Name Datc geleasedgy Date CONDITIONS Adhere to approved appliance.Approved permit shall be onsite for inspections.Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. in PERMIT FEES . Date Description Fee Amount 11/09/2020 Inspection Fee $75.00 11/09/2020 Forced Air Heat $15.00 11/09/2020 Mechanical Base $25.00 11/09/2020 Processing/Technology Fee $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON Dw 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 -BUILDING PERMIT 17522 OSPREY RD Permit#:3535 Permit Expiration Date:05/08/2021 Parcel#: 00809200001900 Valuation: .00 OWNER APPLICANT a CONTRACTOR CARMODY SUSAN E CM Heating CM Heating Inc 17522 OSPREY RD 1415 Broadway 1415 Broadway ARLINGTON,WA 98223 Everett,WA 98201 Everett,WA 98201 425-422-4210 425-259-0550 LIC:CMHEAMH877DN EXP:03/15/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR - CM Heating Inc 1415 Broadway Everett,WA 98201 425-259-0550 LIC#: CMHEAMH877DN EXP: 03/15/2021 LIC#: EXP: JOB DESCRIPTION IL T or- PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: RERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 11/9/2020 Signature Print Name Date geleasedgy Date . CONDITIONS Adhere to approved appliance.Approved permit shall be onsite for inspections.Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. in PERMIT FEES . Date Description Fee Amount 11/09/2020 Inspection Fee $75.00 11/09/2020 Forced Air Heat $15.00 11/09/2020 Mechanical Base $25.00 11/09/2020 Processing/Technology Fee $25.00 Total Due: $140.00 Total Payment: $0.00 Balance Due: $140.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon 4maiwo S*vdard AUD213060MV SPEC-1 B HEATING & AIR CONDITIONING TAG: EM Upf low/Horizontal Gas Furnace - Variable Speed - 2 Stage Heat AUD2B060A9V3VB 5/8" AUD2B060G9V3VA 1 -1/2" 16-1A A�' 5/8"� 28-3/8" 19-5/8" 5/8 4" DIAMETER FLUE CONNECT 7/8" DIA. HOLES ELECTRICAL CONNECTION 8' 4-1/16" � �O 1/2" 3/4" 0 0 2-1/16" 7/8" DIA. K.O. 3-15/16" 0 0 0 ELECTRICAL • 8 1/4" 0 0 CONNECTION 16 40„ (ALTERNATE) 3-3/4 t K.O. GAS CONNECTION 2-1/16" (ALTERNATE) • ' 28-1/4" V% • ' `)` . i 28-1/4" 3/4" 22-1/2" �I 23-1 2" / 5-5/16" 3-13/16" 1-1/2" DIA. HOLE �► �3/$" GAS CONNECTION 2-1/8" ©2013 American Standard Heating&Air Conditioning 'UD213060A9V3VB,'UD213060G9V3VA FURNACE HEATING AIRFLOW(CFM)AND POWER(WATTS)VS.EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING SW7 SW8 0.1 0.3 0.5 0.7 0.9 CFM 589 604 619 604 607 LOW ON ON TEMP.RISE 49 48 47 48 48 WATTS 65 95 125 160 200 HEATING CFM 663 694 684 681 686 1ST MEDIUM" ON OFF TEMP.RISE 44 42 42 42 42 STAGE WATTS 75 120 145 185 220 CFM 775 781 776 805 811 HIGH OFF OFF TEMP.RISE 37 37 37 36 36 WATTS 105 145 180 230 270 CFM 813 818 818 837 842 LOW ON ON TEMP.RISE 55 54 54 53 53 WATTS 110 150 185 240 280 HEATING CFM 907 919 942 958 959 2ND MEDIUM" ON OFF TEMP.RISE 49 48 47 46 46 STAGE WATTS 140 200 240 300 330 CFM 1038 1066 1086 1089 1079 HIGH OFF OFF TEMP.RISE 43 42 41 41 41 WATTS 190 260 325 365 415 'UD213060A9V3VB,-UD2B060G9V3VA FURNACE COOLING AIRFLOW(CFM)AND POWER(WATTS)VS.EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING (TONS) SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 LOW ON ON OFF ON CFM 499 537 520 520 500 (350 CFM/TON) WATTS 50 80 110 145 175 1.5 NORMAL ON ON OFF OFF CFM 605 610 610 597 593 (400 CFM/TON) WATTS 60 80 120 155 180 HIGH ON ON ON OFF CFM 649 681 665 665 672 (450 CFM/TON) WATTS 75 110 145 180 220 LOW OFF ON OFF ON CFM 680 722 680 696 696 (350 CFM/TON) WATTS 80 125 150 190 225 NORMAL OFF ON OFF OFF CFM 798 804 809 823 818 2 (400 CFM/TON) WATTS 105 145 170 235 280 HIGH CFM 884 896 924 931 931 (450 CFM/TON) OFF ON ON OFF WATTS 145 180 240 280 330 LOW CFM 858 863 882 894 895 (350 CFM/TON) ON OFF OFF ON WATTS 125 175 220 275 320 2.5 NORMAL ON OFF OFF OFF CFM 984 1017 1038 1017 1017 (400 CFM/TON) WATTS 170 225 295 330 375 HIGH CFM 1125 1138 1150 1161 1161 (450 CFM/TON) ON OFF ON OFF WATTS 245 315 370 435 475 LOW OFF OFF OFF ON CFM 1035 1056 1076 1076 1076 (350 CFM/TON) WATTS 205 265 330 370 430 3- NORMAL** OFF OFF OFF OFF CFM 1208 1247 1268 1278 1200 (400 CFM/TON) WATTS 300 360 440 485 490 HIGH OFF OFF ON OFF CFM 1380 1410 1402 1350 1235 (450 CFM/TON) WATTS 440 500 550 550 525 NOTES: 1.`FIRST LETTER MAY BE"A"OR"T" 2.-FACTORY SETTING. 3.CONTINUOUS FAN SETTING:HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4.LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON:HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. INDOOR BLOWER TIMING COOLING OFF- DELAY OPTIONS Heating: The ECM Fan Control controls the variable speed NOMINAL- indoor blower. The blower"on"time is fixed at 45 seconds after SWITCH SETTINGS SELECTION AIRFLOW ignition. The FAN-OFF period is field selectable by dip switches 5-OFF 6-OFF NONE SAME #2 and #3 on the Integrated Furnace Control at 60, 100, 140, or 180 seconds. The factory setting is 100 seconds, (See unit 5-ON 6-OFF 1.5 MINUTES 100%" wiring diagram). 5-OFF 6-ON 3 MINUTES 500 Cooling:The fan delay-off period is set by dip switches on the ECM Fan Control board connected to the Integrated Furnace 5-ON 6-ON 50- 100% Control. The options for cooling delay off is field selectable by dip switches #5 and #6. However, dip switch #1 on the Inte- grated Furnace Control must be set to"ON"for cooling mode to *-This selection provides ENHANCED MODE,which function properly. is a ramping up and ramping down of the blower speed to The following table and graph explain the delay-off settings: provide improved comfort, quietness, and potential energy savings.See Wiring Diagram notes on the unit or in the Ser- vice Facts for complete wiring setup for ENHANCED MODE. This selection provides a ramping up and ramping down The graph which follows, shows the ramping process. of the blower speed to provide improved comfort,quietness,and potential energy savings. The graph below shows the ramping process. 100%if necessary 80% Dehumidify 50% 50% Fast Coil Cooling Efficiency OFF OFF 1 I 7.5 I I 3 minute minutes minutes General Data o TYPE U flow/Horizontal VENT COLLAR—Size(in.) 4 Round RATINGS 2 HEAT EXCHANGER 1st Stage Input BTUH 39,000 Type-Fired Alum.Steel 1st Stage Capacity BTUH(I CS) 3 31,200 -Unfired 2nd Stage Input BTUH 60,000 Gauge(Fired) 20 2nd Stage Capacity BTUH(ICS) 3 48,000 ORIFICES—Main Temp.rise(Min.-Max.)°F. 30-60 Nat.Gas.Qty.—Drill Size 3—45 BLOWER DRIVE DIRECT L.P.Gas Qty.—Drill Size 3—56 Diameter-Width(In.) 10 x 7 GAS VALVE Redundant-Two Stage No.Used 1 PILOT SAFETY DEVICE Speeds(No.) VARIABLE SPEED Type Hot Surface Ignition CFM vs.in.w.g. See Fan Performance BURNERS—Type Multiport Inshot Motor HP 1/2 Number 3 R.P.M. VARIABLE POWER CONN.—V/Ph/Hz a 115/1/60 Volts/Ph/Hz 115/1/60 Ampacity(In Amps) 10.5 FLA 7.7 Max.Overcurrent Protection(amps) 15 COMBUSTION FAN-Type Centrifugal PIPE CONN.SIZE(IN.) 112 Drive-No.Speeds Direct-2 DIMENSIONS H x W x D Motor HP-RPM 1/100-2543/1727 Crated(In.) 41-3/4 x 19-1/2 x 30-1/2 Volts/Ph/Hz 115/1/60 Uncrated(In.) 40 x 17-1/2 x 28-1/2 F.L.Amps 0.70/0.40 WEIGHT FILTER—Furnished? Yes Shipping(Lbs.)/Net(Lbs) 136/126 Type Recommended High Velocity Hi Vel.(No.-Size-Thk.)Shipped 1 -17 x 25-1 in. O Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3 O Ratings shown are for elevations up to 2000 feet.For elevations above 2000 feet;Ratings should be reduced at the rate of 4%for each 1000 feet above sea level. O Based on U.S.Government Standard Tests. ®The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. Mechanical Specifications NATURAL GAS MODELS—Central heating BURNERS—Multi-port,in-shotburners will STYLING—Heavy gauge steel and"wrap- furnace designs are certified to ANSI Z21.47 give years of quiet and efficient service. All around" cabinet construction is used in /CSA 2.3 for both natural and L.P.gas. Limit models can be converted to L.P.gas without the cabinet with baked-on enamel finish for setting and rating data were established and changing burners. strength and beauty. The heat exchanger approved under standard rating conditions INTEGRATED SYSTEM CONTROL—Exclu- section of the cabinet is completely lined with using American National Standards Institute sively designed operational program provides foil-faced fiberglass insulation. This results total control of furnace limit sensors,blowers standards. in quiet and efficient operation due to the , excellent acoustical and insulating qualities SAFE OPERATION—The Integrated Sys- gas valve, flame control and includes self of fiberglass. tem Control has solid state devices, which diagnostics for ease of service. continuously monitor for presence of flame, FEATURES AND GENERAL OPERATION AIR DELIVERY—The variable speed,direct- when the system is in the heating mode of — These High Efficiency Gas Furnaces operation. Dual solenoid combination gas drive blower motor, with sufficient airflow employ a Hot Surface Ignition system,which valve and regulator provide extra safety. range for most heating and cooling require- eliminates the waste of a constantly burning ments, will switch from heating to cooling pilot. The integrated system control lights QUICK HEATING— Durable, cycle tested, speeds on demand from room thermostat. the main burners upon demand for heat heavy gauge aluminized steel heat ex- The blower door safety switch will prevent or from the room thermostat. Complete front changer quickly transfers heat to provide terminate furnace operation when the blower service access. warm conditioned air to the structure. Low door is removed. (Fan relay and 35VA control energy power vent blower,to increase ef- transformer is standard). a. Low energy power venter. ficiency and provide discharge of gas fumes b. Vent proving differential switch. to the outside, allows common venting with hot water heater. Since American Standard Heating&Air Conditioning has a policy of continuous product and product data improve- Library ment,it reserves the right to change specifications and Product Section Furnaces design without notice. Product Furnace Technical Literature-Printed in U.S.A. Model AUD2-9V Literature Type Submittal American Standard Sequence Heating&Air Conditioning Date 08/13 6200 Troup Highway C us Tyler,TX 75707 �s�a File No. AUD26060A9V-SPEC-1 B www.americanstandardair.com Intertek Supersedes AUD26060A9V-SPEC 1A Permit#: 3535 Permit Date: 11/09/20 Permit Type: RESIDENTIAL MECHANICAL Project Name: Carmody Applicant Name: CM Heating Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett,WA 98201 Contact: Debbie Bauers Phone: 425-422-4210 Email: debbie@cmheating.com Scope of Work: Replace gas furnace Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 11/10/2020 Permit Expires: 05/09/2021 Form Permit Type: Status: LASERFICHE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning CARMODY SUSAN 120 SINGLE 00809200001900 17522 OSPREY RD E FAMILY RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Plumbing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751W ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION UBI 605890285 ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 11/17/2020 R00.FURNACE 11/17/2020 11/17/2020 BUILDING Approved FINAL Fees Fee Description Notes Amount Inspection $75.00 Forced Air Heat fee per Btu $15.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Credit Card Service $4.20 Total $144.20 Attached Letters Date Letter Description 11/09/2020 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 11/09/2020 DEBBIE BAUERS 83319972 $140.00 11/09/2020 Debbie Bauers CC Surcharge Transaction $4.20 83319972 Outstanding Balance $0.00 Notes Date Note Created By: 11/10/2020 Emailed the permit for signature. Kristin Foster Uploaded Files Date File Name 09/23/2021 9749040-3535 IC 11.17.2020.pdf 11/12/2020 7688643-3535 Issued Permit.pdf 11/09/2020 7666781-3535 Application.pdf