HomeMy WebLinkAbout6910 WOODLANDS WAY_BLD2762_2026 I
CITY OF ARLINGTON
238 N. OLYMPIC AVE - ARLING'FON, WA. 93223
PHONE; (360) 403-3551
BUILDING PERMIT
Address:6910 Woodlands Way Permit N:2762
Parcel 0:00759500000500 Valuation:.00
OWNER APPLICANT CONTRACTOR
Name:ASPIiR FRANC'ES Name: Brennan heating Nartle:Brennan Ileating
Address:6910 WOODLANDS WAY AddressA601 S 134th PI- Address:4601 S 1341h Place
City,State Zip:ARLINGTON,WA 98223 City,Stale lip:Seattle.WA 98168 City,State Zip:Scaltle,WA 98168
Phone: Phone:200-248-7900 Phone:206-2,18-7900
LIC: EXP:
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Nance:Brennan IIcaling Name:
Address 4601 S 134th PL Addres5:
City,State,Zip:Seattle, WA 98168 City,State,Zip;
Phone:206-248-7900 Phone:
LIC 4 HKENNIIA97I R9 EXP 12/29/2019 LIC P: EXP:
JOB DESCRIPTION
PERMIT TYPE: Residential Mechanical CODE YEAR: 2015
STORIES: CONST,TYPE:
DW'ELLWG UNITS: OC'C GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE'l'O CO3MPLY WITH CITY AND STArE LAWS RIiGui-A"rING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY.
NO PERSON WILL BE IIAMPLOYED IN VIOLATION OF THEE LABOR CODE OF THE STXTE OF WASHINGTON RELATING TO WORK-MEN'S
COMPENSATION INSURANCE.-ND RCW 18.27.
THIS APPLIC NI]ON IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR t-IMHER DEPUTY AND ALL PEES ARE PAID.
IT I�,NNLAWFUL-1-0 USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL.INSPECTION ILVS BEEN VADE AND APPROVAL Olt
AX ER' IFICNI'E OF OCCUPANCY HAS BEEN GR\NTED. IBCI 10fIRC'I l0.
/S'l TAX NOTICE:SAWS tax relating to constmclion and consintctton materials in the City of rliti Inn must he reported on ynur sales tax return lurnt
Mid ca cd City of f Arlingla 101,
/ t,c — . :. I'Y` 4 �,�-��� rLa.Q 8/30/19
Signature Print Name Datc cletrticd Date
CONDITIONS
3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated; use of
adhesive tapes are prohibited. Adhere to approved appliance. Call for final inspection.
rf 115 PPR,MIT AUTHORIZES ONLY'rHl:WORK No'rt:t) THIS PERMITC'OVERS WORK TO BE IJONF ON PRIVATE PROPFRTY ONLY ANY
CONSTRUCTION ON TIIE PUBLIC DOMAIN(CURBS,SIDEWSILKS,DRIVEWAYS,N1ARQU1:17S,IETC.)Wll.l.REQUIRI'SFP.ARVI-E PERMISSION.
PERMIT FEES
Date Description Fee Amount
08/30/2019 Heat Pump $25,00
08/30/2019 Mechanical Permit Base Fen S25.00
08/30/2019 Processing/Technology Fee S25.00
Total Due: $75.06
Tnlal Payment: SIM)(1
Balance Due: $75.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When culling for an inspeclion please leave the following information:
Permit Numher Type of Inspection being requested,and whellter you prefer morning or allernonn
I
I
I
Permit#: 2762
Permit Date: 08/30/19
Project Name: Patterson
Applicant Name: Brennan Heating
Applicant Address: 4601 S 134th PL
City, State, Zip: Seattle, WA 98168
Contact: Jaimie How
Phone: 206-248-7900
Email:jaimie@brennanheating.com
Permit Type: Residential Mechanical
Site Address: 6910 Woodlands Way
Valuation: 0.00
Status: Applied
Permit Issued:
Permit Expires:
Square Feet: 0
Type of Construction/Occupancy Load: Residential Mechanical
Number of Stories: 0
Proposed Use: Install ductless HP
MIC/Opportunity Zone:
Status: IN PROCESS
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
143 Single Family
00759500000500 6910 WOODLANDS WAY ASPER FRANCES Residence
Condominium
Multiple
Contractors
Contractor Primary Contact Phone Address Contractor Type License License#
Brennan Heating Jaimie How 206-248-7900 4601 S 134th MECHANICAL Labor and BRENNHA971R9
Place CONTRACTOR Industries
Fees
Fee Description Notes Amount
Heat Pump 322.10.00.00 $25.00
Mechanical Permit Base Fee 322.10.00.00 $25.00
Piucessink/Technology Fee 341.43.00.02 $25.00
Total $75.00
Uploaded Files
Date File Name
08/30/2019 5539093-PattersonMechApp.pdf
RESIDENTIAL MECHANICAL
PERMIT APPLICATION
Department of Community& Economic Development
City of Arlington• 18204 59th Ave NE• Arlington,WA 98223 • Phone(360)403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL
INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES, PLEASE FILL OUT ALL
PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION,
Project Address: (z)_l DO d`a r,A S lJla a ,A `'t _
Project Description: g l UL( C S _
Owner: C0. �..�1-Li!"1 Y1 ?0_�'son
Address: ��
Phone: `tool • ,()3 s - Cp ta� Email:
Applicant: Brennan Heating
Address: 4601 S 134th eattle 98168
Phone: 206-248-79 0 Email: Jaimie@brennanheating.com
Applicant Signatur ' _
Electronic Signature if submitting on-line
l hereby certify that the above information is correct and that the construction, installation for the
above mentioned property will be in accordance with the applicable laws of the City of Arlington
and the State of Washington.
CONTRACTOR INFORMATION
Contractor Name:Brennan Heating
Company: Brennan Heating
License Number:BRENNHA971R9 Expiration: 12129 C{ cl
Phone:206-248-7900 Email:Jaimie@brennanheating.com
STAFF USE ONLY
Permit#: Accepted by: Date:
RESIDENTIAL MECHANICAL
PERMIT APPLICATION
Department of Community & Economic Development
City of Arlington • 1820-1 ',9th Ave NE •Arlington,WA 98223 •Phone(360)403-3551
SELECT ALL PROPOSED APPLIANCES
❑ Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ
Heat Pump ❑ Freestanding Stove ❑ Hydronic Piping
❑ Type it Hood ❑ Commercial Cooking Appliance ❑ Pv System
❑ Boiler ❑ Gas Piping ❑ Storage Tank
❑ AC Unit ❑ Solid-Fuel Appliance ❑ Other
Gas Piping Information
Not Applicable: ❑
Pipe Material:
Pipe Size:
Distance From Meter to Furthest Appliance:
Total BTU's of all Appliances:
• New gas piping requires a pressure test to hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper Combustion air and venting required for all appliances
• A shut-off valve is required within 6 feet of all appliances
r
♦ 1
T r y
t
dp-
L _
► - - — --,
t a�� is rr • ----
pm='c + `:
r
10
: + r
Y ..
SPECIFICATIONS - OUTDOOR UNITS
Nominal Size -Tons 0.75 1 1.5 2
Outdoor Unit Model No. MLA009S4S MLA012S4S MLA018S4S MLA024S4S
Ambient Temperature Operating Cooling -22- 122 -22- 122 -22 - 122 -22- 122
Range -°F Healing -22-86 -22-86 -22-86 -22-86
Sound Data(dBA) Cooling 52 52 56 57
Heating 57 57 59 60
Refrigerant Charge furnished(R-410A) 3 lbs. 3 oz. 3 lbs. 3 oz. 4 lbs.3 oz. 5 lbs- 7 oz
Maximum line length with furnished charge-ft. 25 25 25 25
Additional charge required per ft. -oz. 0.16 0.16 0.16 032
Compressor No. and Type Rotary Rotary Rotary Rotary
Refrigerant oil type Ester Oil VG74 Ester Oil VG74 POE VG74 POE VG74
Refrigerant oil charge-oz. 16.9 16.9 227 22.7
Connections -in. Liquid/Gas pipe(flare) 1/4/318 V4/1/2 114/1/2 3/8/5/8
Maximum refrigerant pipe length-ff. 82 82 98 164
Max.difference in level of indoor unit-ft. 33 33 66 82
Outdoor (No-) Diameter-in. (1) 17 (1) 17 (1) 19 (1)22
Fan Total air volume-cfm 1120 1180 1355 2355
rpm 810 810 850 810
Outdoor Coil Number of rows 2 2 2 2
Fins per inch 18 18 18 19
Fin type Hydrophilic aluminium
Tube outside diameter-in. 3/8 318 318 3/8
Tube type Rifled copper tubing
Net face area-ft.' 4.73 4.73 5.19 8.16
Design Pressure PSIG 550/340 550/340 5501340 550/340
Shipping Data Net/Shipping weight(lbs,) 88/94 88/94 108/115 136/149
ELECTRICAL DATA
Electrical Characteristics -60 Hz-1 Phase 2081230V 208/230V 206/230V 208/230V
Maximum Overcurrent Protection(amps) 15 15 25 30
2 Minimum circuit ampacity 9 9 18 20
Compressor Rated load amps 5.25 5.65 12.3 14
Outdoor Fan Motor Rated load amps 038 0.38 0.42 0.5
Output-W 40 40 44 120
NOTE-Eitroinas of operating range are plus and rninus W14,of line voltage
HACR type circuit breaker or fuse.
Refer to National or Canadian Eloctnrai Code manual to determine wire,fuse and disconnect size requirements
Low Ambient Single Zone Mini-Split Systems/Pane 15
SPECIFICATIONS - WALL-MOUNTED INDOOR UNITS
Model No. MWMA009S4 MWMA012S4 MWMA018S4 MWMA024S4
Nominal Tons 0.75 1 1 5 2
Power Supply-60 hz- I phase 2081230V 208/230V 208/230V 208/230V
Rated load amps 02 0.2 04 0.5
Output(W) 20 20 58 60
Room Temperature Cooling 62 -90 62-90 62-90 62-90
Range("F) Heating 32-86 32-86 32-86 32-86
Air Volume -cfm (HighiMedium/Low) 370/270/195 370/2751200 530/4101295 6951625/485
Sound Data (dBA)-LowlMedium/High 26.5/33 4/41.7 28.6135.8/45.1 30,9/36,3/46.2 35.1/44.5/51.7
Piping Connections- Liquid/Gas-o_d.-flare-in. 1/4/3/8 114/1/2 1l4 11/2 3/8/5/8
Drain connection o.d.-in. 1 1 1 1
NetlShipping weights-lbs. 20/26 20/27 27135 40154
SPECIFICATIONS - CASSETTE INDOOR UNITS
Model No. M22AO09S4 M22AO12S4 M22AO18S4 M33AO24S4
Nominal Tons 0 75 1 1.5 2
Power Supply-60 hz- 1 phase 208/230V 208/230V 2081230V 208/230V
Rated load amps 0,9 1.0 1.5 15
Output(W) 46 46 46 42
Room Temperature Cooling 62-90 62-90 62-90 62-90
Range("F) Heating 32 -86 32-86 32-86 32-86
Air Volume-cfm (High/MediumiLow) 375/300/255 3801310/260 5601485/415 7 001635/575
Sound Data(dBA)-Low/Medium/High 33/37/41 36/39/43 36/39/44 43/47/51
Piping Connections-Liquid/Gas-o.d.-flare-in. 114/318 1/4/ 1/2 1/4/1/2 3/8/5/8
Drain connection o.d -in. 1 1 1 1-1/4
Net/Shipping weights-lbs Body 32/38 36/41 36/42 47/55
REQUIRED COMPONENTS - ORDERED SEPARATELY
Cassette Panel 13XO4 13XO4 13XO4 13XO5
(MOSTAT620-1) (MOSTAT620-1) (MOSTAT620-1) (MOSTAT630-1)
Net/Shipping weights -lbs. 6/ 10 6/ 10 6/ 10 12/ 18
Low Ambient Single Zone Mini-Split Systems/Page 16
1
�t
11anie Espanol Contact
Industries
Labor •
Safety&Health 1, Claims&Insurance Workplace Rights .•- e •
Alft Washington State Department of
ULabor & Industries
BRENNfAN MEAUNG &A/C LLC
Owner or tradesperson 4601 S 134TH PL
Principals SEATTLE,WA 98168
ERDAHL,DARRIN PAUL,PARTNER/MEMBER 206-248-7900
Doing business as KING County
BRENNAN HEATING&A/C LLC
WA UBI No. Business type
602 346 866 Limited Liability Company
Governing persons
DARRIN
P
ERDAHL
ERIC BEARDEMPHL;
Certifications&Endorsements
License
Verify the contractor's active registration/license/certification(depending on trade)and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
BRENNHA971R9
Effective—expiration
12/29/2003-12129/2019
Bond
FEDERATED MUTUAL INS CO $12,000.00
Bond account no.
9127230
Received by L&I Effective date
11/04/2004 12/22/2004
Expiration date
Until Canceled
Insurance
Federated Mutual Ins Co $1,000,000.00
Policy no.
9820726
Received by L&I Effective date
05/29/2019 07/13/2015
Expiration date
0 7/1 312 0 2 0
Insurance history
Savings
.............. ...
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsu,its against the bond or savings a, mounts during the previous 6 year period.
L&I Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts
may be recorded by other agencies.
License Violations
Infraction no.
PDOVE00515 Satisfied
Issue date RCW/WAC
01/26/2018 18.106.020
Violation city Violation amount
SEATTLE $250.00
Type of violation
PLUMBER INFRACTION
Description
Contractor employed a person to engage in
the trade of plumbing without a current
journeyman,specialty or trainee certificate,
temporary permit or medical gas endorsement
as required.
Workers'corner
Public Works Requirements
Workplace safety and health
access
Help�us improve
a.,.►4vashin�tan'°
CITY OF ARLINGTON
238 N. OLYMPIC AVE -ARLINGTON, WA. 98223
PHONE; (360) 403-3551
BUILDING PERMIT
Address:6910 Woodlands Way Permit#:2762
Parcel#:00759500000500 Valuation:.00
OWNERS APPLICANT CONTRACTOR
Name:ASPER FRANCES Name:Brennan Heating Name:Brennan Heating
Address:6910 WOODLANDS WAY Address:4601 S 134th PL Address:4601 S 134th Place
City,State Zip:ARLINGTON,WA 98223 City,State Zip:Seattle,WA 98168 City,State Zip:Seattle,WA 98168
Phone: Phone:206-248-7900 Phone:206-248-7900
LIC: EXP:
MECHANICAL CONTRACTOR PLUMBING CONTRACTO
Name:Brennan Heating Name:
Address:4601 S 134th PL Address:
City,State,Zip:Seattle,WA 98168 City,State,Zip:
Phone:206-248-7900 Phone:
LIC#:BFENNHA97IR9 EXP: 12/29/2019 LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Residential Mechanical CODE YEAR: 2015
STORIES: CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;
NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110.
SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form
and coded City of Arlington#3101.
8/30/19
Signature Print Name Date eleased Date
CONDITIONS
3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated; use of
adhesive tapes are prohibited. Adhere to approved appliance. Call for final inspection.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
08/30/2019 Heat Pump $25.00
08/30/2019 Mechanical Permit Base Fee $25.00
08/30/2019 Processing/Technology Fee $25.00
Total Due: $75.00
Total Payment: $0.00
Balance Due: $75.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
Permit#: 2762
Permit Date: 08/30/19
Permit Type: RESIDENTIAL MECHANICAL
Project Name: Patterson
Applicant Name: Brennan Heating
Applicant Address: 4601 S 134th PL
Applicant, City, State, Zip: Seattle,WA 98168
Contact: Jaimie How
Phone: 206-248-7900
Email:jaimie@brennanheating.com
Scope of Work: Install ductless HP
Valuation: 0.00
Square Feet: 0
Number of Stories: 0
Construction Type:
Occupancy Group:
ID Code:
Permit Issued: 09/03/2019
Permit Expires:
Form Permit Type:
Status: LASERFICHE
Assigned To: Raelynn Jones
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
143 Single Family
00759500000500 6910 WOODLANDS WAY ASPER FRANCES Residence
Condominium
Multiple
Contractors
Contractor Primary Contact Phone Address Contractor Type License License#
Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL COA 602 346 866
CONTRACTOR
Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL Labor d BRENNHA971R9
CONTRACTOR Industri anes
Fees
Fee Description Notes Amount
Heat Pump/Heat Exchangers $25.00
Mechanical Base Permit Fee $25.00
Processing/Technology $25.00
Credit Card Service $2.25
Total $77.25
Attached Letters
Date Letter Description
08/30/2019 Building Permit
08/30/2019 Building Permit
Payments
Date Paid By Description Payment Type Accepted By Amount
08/30/2019 Brennan Heating 76807722 $75.00
08/30/2019 76807722 CC Surcharge Raelynn Jones $2.25
Outstanding Balance $0.00
Uploaded Files
Date File Name
08/30/2019 5539093-PattersonMechApp.pdf
RESIDENTIAL MECHANICAL
PERMIT APPLICATION
Department of Community 8 Economic Development
City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL
INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL
PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION.
Project Address: �O`l lJv DO d 0.n g s l�a 'A, I
Project Description:' .(
Owner: C. r'') Y1.c-. ?0-
Address: n
Phone: q • 3 �V t5x Email:
Applicant: Brennan Heating
Address: 4601 S 134thptleattle 98168
Phone: 206-248-79 0 AEmail: Jaimie@brennanheating.com
Applicant Signatur
Electronic Signature if submitting on-line
! hereby certify that the above information is correct and that the construction, installation for the
above mentioned property will be in accordance with the applicable laws of the City of Arlington
and the State of Washington.
CONTRACTOR INFORMATION
Contractor Name:Brennan Heating
Company: Brennan Heating
License Number:BRENNHA971R9 Expiration: 12/29
Phone:206-248-7900 Email:Jaimie@brennanheating.com
STAFF USE ONLY
Permit#: Accepted by: Date:
RESIDENTIAL MECHANICAL
IN PERMIT APPLICATION
Department of Community& Economic Development
City of Arlington • 18204 59th Ave NE • Arlington,WA 98223 • Phone(360)403-3551
SELECT ALL PROPOSED APPLIANCES
❑ Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ
Heat Pump ❑ Freestanding Stove ❑ Hydronic Piping
❑ Type II Hood ❑ Commercial Cooking Appliance ❑ Pv System
❑ Boiler ❑ Gas Piping ❑ Storage Tank
❑ AC Unit ❑ Solid-Fuel Appliance ❑ Other
Gas Piping Information
Not Applicable: ❑
Pipe Material:
Pipe Size:
Distance From Meter to Furthest Appliance:
Total BTU's of all Appliances:
• New gas piping requires a pressure test to hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper Combustion air and venting required for all appliances
• A shut-off valve is required within 6 feet of all appliances
' N
i
4
• Irk-
SPECIFICATIONS - OUTDOOR UNITS
Nominal Size-Tons 0.75 1 1.5 2
Outdoor Unit Model No. MLA009S4S MLA012S4S MLA018S4S MLA024S4S
Ambient Temperature Operating Cooling —22- 122 —22- 122 —22- 122 —22- 122
Range-OF Heating —22-86 —22-86 —22-86 —22-86
Sound Data(dBA) Cooling 52 52 56 57
Heating 57 57 59 60
Refrigerant Charge furnished(R410A) 3 lbs. 3 oz. 3 lbs. 3 oz. 4 lbs.3 oz. 5 lbs. 7 oz.
Maximum line length with furnished charge-ft. 25 25 25 25
Additional charge required per ft. -oz. 0.16 0.16 0.16 0.32
Compressor No. and Type Rotary Rotary Rotary Rotary
Refrigerant oil type Ester Oil VG74 Ester Oil VG74 POE VG74 POE VG74
Refrigerant oil charge-oz. 16.9 16.9 22.7 22.7
Connections-in. Liquid/Gas pipe(flare) 1/4/3/8 1/4/1/2 1/41 1/2 3/8/5/8
Maximum refrigerant pipe length-ft. 82 82 98 164
Max. difference in level of indoor unit-ft. 33 33 66 82
Outdoor (No.)Diameter-in. (1) 17 (1) 17 (1) 19 (1)22
Fan Total air volume-cfm 1120 1180 1355 2355
rpm 810 810 850 810
Outdoor Coil Number of rows 2 2 2 2
Fins per inch 18 18 18 19
Fin type Hydrophilic aluminium
Tube outside diameter-in. 318 3/8 3/8 3/8
Tube type Rifled copper tubing
Net face area-ft.z 4.73 4.73 5.19 8.16
Design Pressure PSIG 550/340 550/340 550/340 550/340
Shipping Data Net/Shipping weight(lbs.) 88194 88/94 108/115 1361149
ELECTRICAL DATA
Electrical Characteristics-60 Hz-1 Phase 208/230V 208/230V 208/230V 208/230V
Maximum Overcurrent Protection(amps) 15 15 25 30
1 Minimum circuit ampacity 9 9 18 20
Compressor Rated load amps 5.25 5.65 12.3 14
Outdoor Fan Motor Rated load amps 0.38 0.38 0.42 0.5
Output-W 40 40 44 120
NOTE-Extremes of operating range are plus and minus 101A.of line voltage.
HACR type circuit breaker or fuse.
Refer to National or Canadian Electrical Code manual to determine wire.fuse and disconnect size requirements.
Low Ambient Single Zone Mini-Split Systems/Page 15
SPECIFICATIONS - WALL-MOUNTED INDOOR UNITS
Model No. MWMA009S4 MWMA012S4 MWMA018S4 MWMA024S4
Nominal Tons 0.75 1 1.5 2
Power Supply-60 hz- 1 phase 208/230V 208/230V 208/230V 208/230V
Rated load amps 0.2 0.2 0.4 0.5
Output(W) 20 20 58 60
Room Temperature Cooling 62-90 62-90 62-90 62-90
Range(°F) Heating 32-86 32-86 32-86 32-86
Air Volume-cfm(High/Medium/Low) 370/270/195 370/275/200 530/410/295 695/625/485
Sound Data(dBA)-Low/Medium/High 26.5/33.4/41.7 28.6/35.8/45.1 30.9/36.3/46.2 35.1/44.5/51.7
Piping Connections-Liquid/Gas-o.d.-flare-in. 1/4/3/8 1/4/1/2 1/4/1/2 3/8/5/8
Drain connection o.d. -in. 1 1 1 1
Net/Shipping weights-lbs. 20/26 20/27 27/35 40/54
SPECIFICATIONS - CASSETTE INDOOR UNITS
Model No. M22A009S4 M22A012S4 M22A018S4 M33A024S4
Nominal Tons 075 1 1.5 2
Power Supply-60 hz- 1 phase 208/230V 208/230V 208/230V 208/230V
Rated load amps 0.9 1.0 1.5 1.5
Output(W) 46 46 46 42
Room Temperature Cooling 62-90 i 62-90 62-90 62-90
Range(`F) Heating 32-86 32-86 32-86 32-86
Air Volume-cfm(High/Medium/Low) 375/300/255 380/310/260 560/485/415 700/635/575
Sound Data(dBA)-Low/Medium/High 33/37/41 36/39/43 36/39/44 43/47/51
Piping Connections-Liquid/Gas-o.d.-flare-in. 1/4/3/8 1/4/1/2 1/41 1/2 3/8/5/8
Drain connection o.d.-in. 1 1 1 1-114
Net/Shipping weights-lbs. Body 32/38 36/41 36/42 47/55
REQUIRED COMPONENTS - ORDERED SEPARATELY
Cassette Panel 13XO4 13X04 13X04 13X05
(MOSTAT620-1) (MOSTAT62Q-1) (MOSTAT620-1) (MOSTAT630-1)
Net/Shipping weights-lbs. 6/10 6/ 10 6/ 10 12/18
Low Ambient Single Zone Mini-Split Systems/Page 16