Loading...
HomeMy WebLinkAbout18117 Cedarbough Loop_BLD5850_2025 Permit Packet Coversheet Community and Economic Development City of Arlington • 18204 59th Avenue NE • Arlington, WA 98223 • Phone (360) 403-3551 Permit Number: BLD5850 Permit Type: Residential Mechanical Address/Parcel: 18117 Cedarbough Loop Completed (Month/Year): April 2024 Land Use Bonding or Assignment of Funds Notice of Decision o Confidential Documents. Contact the Staff Report City to obtain. Application As-Builts Narrative Letters and Project Documents Legal Description Other: Vicinity Map Site Plan Civil Landscape Plan Issued Permit Complete Streets Checklist Application Traffic Impact Analysis Other Applications Snohomish County Traffic Mitigation Offer Construction Calculation Worksheet WSDOT Traffic Offer Form Approved Plans Tree Survey Review Comment Form Stormwater Drainage Report Letters and Project Documents Geotech Report Other Agency Permits Critical Area Evaluation Form Reports: SEPA Checklist o Drainage Report Pg: Public Notice Material o Stormwater Pg: Noticing and Related Documents o Geotech Pg: Water / Sewer Availability Certificate o All Other Reports Unanticipated Discovery Plan Form SEPA and Noticing Materials Aerial Photo of Site Inspections Proposed Building Materials As-Builts Lighting Plans and Lighting Cut Sheets Other: Color Elevations Design Matrix Building Plat Map ✔ Issued Permit Title Report ✔ Application Lot Closures Additional Applications Preliminary Civil Plans Approved Plans Archaeological Survey ✔ Site Plan o Confidential Documents. Contact the Letters and Project Documents City to obtain. Calculations Topography (Existing Conditions) ✔ Project Specification Manuals CC&R’s Reports Deeds / Easements / Conveyances Certificate of Occupancy /Dedications Inspections Developer’s Agreement Other: Letters and Project Documents Page 1 of 1 TDD2B080ACV-SUB-1E TAG: _________________________________ SUBMITTAL TDD2B080ACV32B Communicating or 24V ADD2B080ACV32B non-communicating Downflow/Horizontal Direct/Non-Direct Vent 2 Stage Gas Furnace with Variable Speed Inducer 5/8" 17-1/2" 28" 24-1/2" 16-1/4" 19-5/8" 5/8" SIDE PANEL 1/2" CUTOUT FOR 5" O SIDE PANEL CUTOUT HORIZONTAL FOR HORIZONTAL VENTING VENTING THROUGH THE CABINET 9-5/8" THROUGH 4-1/8" THE CABINET 7/8" DIA. HOLES ELECTRICAL 3-1/2 5" CONNECTION 3-3/8 40" 7/8" HOLE 7" WITH PLUG 3/4" FLUE 2-1/8" OPENING 31 4" O 2-1/8" 16" 29-1/2" 1-5/8” HOLE WITH PLUG 3/4" 1-1/2" DIA. GAS CONNECTION 20-1/4" (ALTERNATE) 1-5/8” HOLE 3/4" 3-15/16" WITH PLUG 12-3/8" 10" 10" 19" 7-3/8" 8-1/4" 5-5/16" 1/2" 1-5/8” HOLE WITH PLUG 3-3/4” 1-5/8" DIA. HOLE WITH PLUG GAS CONNECTION (ALT) 1-5/8” HOLE WITH PLUG © 2016 Ingersoll Rand *DD2B080ACV Airflow - Heating *DD2B080ACV32B Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 644 680 695 703 717 650 TEMP RISE 60 56 55 55 53 WATTS 66 91 108 129 167 HEATING CFM 723 754 766 770 778 1ST 728 TEMP RISE 53 51 50 50 49 STAGE WATTS 70 106 134 164 203 CFM 816 841 849 848 849 819 TEMP RISE 47 46 45 45 45 WATTS 82 127 167 205 244 CFM 1001 1013 1014 1005 990 1000 TEMP RISE 59 58 58 59 60 WATTS 131 186 237 284 319 HEATING CFM 1123 1128 1123 1108 1083 2ND 1120 TEMP RISE 53 52 53 53 54 STAGE WATTS 181 236 288 335 365 CFM 1266 1261 1250 1229 1192 1260 TEMP RISE 47 47 47 48 49 WATTS 256 306 351 394 413 *DD2B080ACV Airflow - Cooling *DD2B080ACV32B Furnace Cooling Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter OD AIRFLOW 0.1 0.3 0.5 0.7 0.9 CFM 723 742 738 726 715 290 WATTS 63 98 130 162 196 CFM 871 891 891 881 868 350 WATTS 94 138 176 210 247 2.5 CFM 1006 1019 1022 1013 1000 400 WATTS 134 182 224 265 307 CFM 1123 1131 1129 1120 1108 450 WATTS 182 235 282 326 367 CFM 868 891 884 877 866 290 WATTS 95 137 176 208 245 CFM 1055 1059 1063 1052 1045 350 WATTS 155 199 246 288 329 3.0 CFM 1193 1192 1202 1200 1193 400 WATTS 216 266 320 372 422 CFM 1355 1359 1359 1356 1300 450 WATTS 308 368 427 484 500 CFM 1026 1039 1040 1029 1017 290 WATTS 142 188 232 272 311 CFM 1225 1231 1239 1235 1231 350 WATTS 224 281 336 386 437 3.5 CFM 1412 1408 1410 1397 1319 400 WATTS 333 390 462 509 504 CFM 1596 1544 1469 1387 1315 450 WATTS 492 516 512 509 508 NOTES: 1. *FIRST LETTER MAY BE “A” OR “T’ 2. **FACTORY SETTING 3. CONTINUOUS FAN SPEED SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE. 4. WITH VARIABLE SPEED OUTDOOR UNIT APPLICATION, THE LOW SPEED AIRFLOWS ARE APPROXIMATELY 30% OF LISTED VALUES. 5 LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATIONS FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. 6. CONTINUOUS FAN MODE DURING COOLING OPERATION MAY NOT BE APPROPRIATE IN HUMID CLIMATES. IF THE INDOOR AIR EXCEEDS 60% RELA- TIVE HUMIDITY OR SIMPLY FEELS UNCOMFORTABLY HUMID, IT IS RECOMMENDED THAT THE FAN ONLY BE USED IN THE AUTO MODE. Airflow Adjustment Check inlet and outlet air temperatures to make sure 1 PRODUCT SPECIFICATIONS they are within the range specified on the Furnace rat- ing nameplate. If the airflow needs to be increased or MODEL *DD2B080ACV32B decreased, see the Airflow Label on the Furnace or the TYPE Downflow / Horizontal RATINGS 2 unit’s Service Facts for information on changing the speed 1st Stage Input BTUH 52,000 of the Blower Motor for your specific model. Blower speed 1st Stage Capacity BTUH (ICS) 3 41,600 changes are made on the User Interface. 2nd Stage Input BTUH 80,000 2nd Stage Capacity BTUH (ICS) 3 63,000 INDOOR BLOWER TIMING Temp. rise (Min.-Max.) °F. 35 - 65 Heating: The Integrated Furnace Control module con- BLOWER DRIVE 7 Direct Diameter - Width (In.) 10 x 7 trols the Indoor Blower. The Blower start is fixed at 45 No. Used 1 seconds after ignition. The FAN-OFF period is field se- Speeds (No.) Variable lectable by the User Interface at 60, 100, 140, or 180 sec- CFM vs. in. w.g. See Airflow Table onds. The factory setting is 100 seconds. Motor HP 1/2 R.P.M. Variable Volts / Ph / Hz 115/1/60 FLA 5.2 COMBUSTION FAN — Type Centrifugal Drive - No. Speeds Direct - 2 Motor HP - RPM 1/100 - 2543/1727 Volts / Ph / Hz 115/1/60 FLA 0.70/0.40 FILTER — Furnished? Yes Type Recommended High Velocity Hi Vel. (No.-Size-Thk.) 2 - 14x20 - 1in. VENT — Size (In.) 4 Round HEAT EXCHANGER Type -Fired Alum. Steel - Type 1 -Unfired Gauge (Fired) 20 ORIFICES — Main Nat. Gas. Qty. — Drill Size 4 — 45 L.P. Gas Qty. — Drill Size 4 — 56 GAS VALVE Redundant - Two Stage PILOT SAFETY DEVICE Type Hot Surface Ignition BURNERS — Type Multi-port In-shot Number 4 POWER CONN. — V / Ph / Hz 4 115/1/60 Ampacity (In Amps) 7.8 Max. Overcurrent Protection (Amps) 15 PIPE CONN. SIZE (In.) 1/2 DIMENSIONS H x W x D Crated (In.) 41-3/4 x 19-1/2 x 30-1/2 WEIGHT Shipping (Lbs.) / Net (Lbs.) 146 / 136 * May be "T" or "A" 1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3.. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. 3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 5 Furnace ships in natural gas configuration. The LP conversion kit used with the 2 stage furnace is BAYLPSS210B or BAYLPKT210B. 6 First stage output capacity is approximately equal to 65% of second stage capacity. 7 Direct drive variable speed blower motor is an ECM constant airflow blower motor. Mechanical Specifications COMMUNICATING MODE QUICK HEATING ENERGY EFFICIENT OPERATION Furnace is shipped ready to be con- Durable, cycle tested, heavy gauge alu- Furnace is certified to leak 2% or less of nected in communicating mode using minized steel heat exchanger quickly nominal air conditioning CFM delivered three wire hook-up using T/ACONT900 transfers heat to provide warm condi- when pressurized to .5” water column comfort control. tioned air to the structure. Low energy with all inlets, outlets, and drains sealed. power vent blower, to increase ef- ALTERNATE 24V MODE STYLING ficiency and provide a positive discharge Furnace is field configurable to 24V non- Heavy gauge steel and “wrap-around” of gas fumes to the outside. communicating mode. cabinet construction is used in the COMFORT CONTROL BURNERS cabinet with baked-on enamel finish for The communicating furnace design Multiport In-shot burners will give years strength and beauty. The heat exchanger of quiet and efficient service. All models section of the cabinet is completely lined offers plug and play – walk away in- can be converted to L.P. gas. with foil faced fiberglass insulation. This stallation. Assures the entire heating results in quiet and efficient operation and air conditioning system is set up in INTEGRATED SYSTEM CONTROL due to the excellent acoustical and the proper modes to optimize the en- Exclusively designed operational pro- insulating qualities of fiberglass. Built-in gram provides total control of furnace gineered performance of the matched bottom pan and alternate bottom, left or limit sensors, blowers, gas valve, flame system installed. right side return air connection provision. control and includes self diagnostics for NATURAL GAS MODELS ease of service. Also includes connec- Central Heating furnace designs are cer- FEATURES AND GENERAL OPERATION tion points for E.A.C./humidifier. tified by the American Gas Association The High Efficiency Gas Furnaces em- for both natural and L.P. gas. Limit set- AIR DELIVERY ploy a Hot Surface Ignition system, which ting and rating data were established and The variable speed, direct drive blower eliminates the waste of a constant burn- approved under standard rating condi- motor, has sufficient airflow for most ing pilot. The integrated system control tions using American National Standards heating and cooling requirements, will lights the main burners upon a demand Institute standards. switch from heating to cooling speeds for heat from the room thermostat. Com- on demand from room thermostat. The plete front service access. SAFE OPERATION blower door safety switch will prevent or a. Low energy power venter The Integrated System Control has solid terminate furnace operation when the b. Vent proving pressure switch. state devices, which continuously monitor blower door is removed. for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety. Ingersoll Rand has a policy of continuous product and product data improvement and it reserves the right to change specifications and design without notice. Publication Number TDD2B080ACV-SUB-1E Supersedes TDD2B080ACV-SUB-1D Ingersoll Rand Date 12/16 6200 Troup Highway Tyler, TX 75711-9010 Since the manufacturer has a policy of continuous product and product data improve- ment, it reserves the right to change design and specifications without notice.       !  "#$% &'() *+$,% )-./0-)1!2'03(4'(.3- *+$,*5566 7 80'0292:302; *+$,<=<><? '-@/93AA2BC8 D =",$ E2//3F'FG:2-1'( H", I J IJ8 78 K+ )LL3F2M()-./0-)1G2'03(4NF)1 >$""OP"Q 3R23(R3(.L:-('F2-2&A'F212(0 S+T",  N >UTV  %TW"O>"6  =",6T$", XY Z$$T,$["T J\2/3.2(03'A ] ="5 ]66T5   K^6   V"  !  >T6 _` *66a,5" 12-2/3''bA3/ " `'-F2Ac ..-2//24'A2/F-3&03)(_b(2-'12 _b(2-`G)(2 d)(3(4 7 ; 7 77D Y_e;! `_eE D  78 hg __` fg   =",$"6 )(0-'F0)-`-31'-@ )(0'F0`G)(2..-2// )(0-'F0)-@&23F2(/2 3F2(/2c __ 7 80'0292N _e _  J J 8 _ I 7DII7D !;f 02N; _ _ __ 7 80'0292N _e _ 'i)-f  J J 8 _!DD !;f 02N; _ _ (.:/0-32/ ],6$",6 '02(/&2F03)(@&22/F-3&03)(FG2.:A2.'02 )1&A202.'02(/&2F0)-0'0:/        !"#$#%$!&'%$ ("!!#%)*"+%,)- . %!"$#% ./ "0#0 1$0200*+ %$03040'%#$! . "+1%#"1,01!(&#$0 . #$0 105#" .  6789: ;<==>?@ A889BCD0E88F 1$ $$!"#$#% G HIJKLJMN0OPQRJS G TPU0VWQRX0YPZJLPMSJ[K0\P]^[MJ][K0_``KJ][SJWM a9bcd8 1$ (1#0-!"#$#%(1-&%$0*-""$0-&'%$ e(0 %4f G . ggGG G &!#101h,#! .  ij8 89dDkdl0m9:9dB ;@>@@ no:79DD0k: 1$ #,01& G pqrqstuvXwxwuxwwuyHz{sqsxy|ZZIPLOPQRJS}`L~ G ]]rps[Ppurvrsx~P[]LrpL[rstpL[UtuySLLwUxqx[]XZIURJSS[KXZ[RyZ`[MW}`L~ G vtv]]vpLsqru€twu~LUru]xrxUxUvPsUyZJSPy`K[MyZ[RyZ`[MW}`L~ G urwqvuUqqt€LwL]qwwqUPquw]xUP]v~vyZ[RyZ`[MWy[QKJMNSWMy[``KJ][SJWM}`L~