Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18230 Champions Dr_BLD2776_2026
363658-CTG-1-1018 DESCRIPTION These compact units employ induced combustion, reliable hot =7/ surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications. HEATING & AIR CONDITIONING These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room, or garage and TECHNICAL GUIDE are also ideal for commercial applications.All units are factory GAS-FIRED RESIDENTIAL assembled, wired and tested to assure safe dependable and SINGLE STAGE MULTI-POSITION economical installation and operation. GAS FURNACES These units are Category I listed and may be common vented STANDARD & Low NOx MODELS with another gas appliance as allowed by the National Fuel Gas Code. MODELS: TG8S / TGLS FEATURES NATURAL GAS Easily applied in upflow, horizontal left or right, or downflow 40 -130 MBH INPUT installation with minimal conversion necessary. • Compact, easy to install, ideal height 33"tall cabinet. • Blower-off delay for cooling SEER improvement. • Easy access to controls to connect power/control wiring. • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation. • Low unit amp requirement for easy replacement application. Single wire twinning or staging feature available. • All models are convertible to use propane (LP)gas. • Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability. 100%shut off main gas valve for extra safety. • 4 speed, direct drive PSC motor. • 24V,40 VA control transformer and blower relay supplied for add-on cooling. • Hi-tech tubular aluminized steel primary heat exchanger. • Timed on, adjustable off blower capability for maximum com- fort. Blower door safety switch. • Low NOx models have been designed to meet specific code requirements. pE51GN ' rs°9000REGiSG700� • Airflow leakage less than 1%of total airflow at duct perfor- IS0 9001 mance testing conditions. SB Certified Quality Management System No knockouts to deal with, making installation easier. Movable duct connector flanges for application flexibility. Due to continuous product improvement, specifications Quiet inducer operation. are subject to change without notice. Inducer rotates for easy conversion of venting options. Visit us on the web at www.york.com Fully supported blower assembly for easy access and Additional rating information can be found at removal of blower. www.ahridirectory.orq External air filters used for maximum flexibility in meeting customers IAQ needs. WARRANTY Venting applications-may be installed as a common vent 20-year limited warranty on the heat exchanger. with other gas-fired appliances or use a masonry chimney. 10-year heat exchanger warranty on commercial applications. 1/4 turn knobs provided for easy door removal. Standard 5-year limited Parts warranty. Extended 10-year limited parts warranty when product is registered online within 90 days of purchase for replace- ment or closing for new home construction. FOR DISTRIBUTION USE ONLY- NOT TO BE USED AT POINT OF RETAIL SALE 363658-CTG-1-1018 LEFT SIDE Vent Connection FRONT RIGHT SIDE OOutlet Electrical Entry Electrical Vent Entry Connection • o Outlet 01W Gas Pipe Gas Pipe o Entry Entry ® ® 33" r ® ® 23" ° Thermostat o Thermostat t Wiring Wiring 14" L J L J 28.5" A 29.5" 4"Diameter .5" 24.38 Vent Outlet Connection ,5°��� B C B .5" 20" 24.25"� SUPPLY END RETURN END Cabinet and Duct Dimensions Nominal Cabinet Cabinet Dimensions(Inches) Approximate Models Operating Weights CFM(m3/min) Size A B C Lbs TG(8,L)SO4OAO8MP11 800 A 14 112 13 3/8 10.3 89 TG(8,L)S060A10MP11 1000 A 14 1/2 13 3/8 10.3 91 TG(8,L)S060Al2MP11 1200 A 14 1/2 13 3/8 10.3 94 TG(8,L)S080B12MP11 1200 B 17 1/2 16 3/8 11.8 103 TG(8,L)S080C16MP11 1600 C 21 19 7/8 13.6 114 TG(8,L)SO8OC22MP11 2200 C 21 19 7/8 13.6 119 TG(8,L)S100B12MP11 1200 B 17 112 16 3/8 11.8 108 TG(8,L)S100C16MP11 1600 C 21 19 7/8 13.6 118 TG(8,L)S100C20MP11 2000 C 21 19 7/8 13.6 122 TG8S120C16MP11 1600 C 21 19 7/8 15.8 123 TG(8,L)S120C20MP11 2000 C 21 19 7/8 1 15.8 1 129 TG8S130D20MP11 2000 D 1 24 1/2 1 23 3/8 17.5 135 Ratings&Physical/Electrical Data Air Temp. Max. Recommended Outlet Blower Gas Pipe Input Output AFUE Blower Fuse or Circuit Total Unit Models Rise Air Temp Size BreakerAmps Amps Connection, NPT MBH MBH % °F °F HP Amps Inches Amps TG(8,L)SO4OAO8MP11 40 32 80.0 25-55 190 1/5 2.1 9 x 8 15 3.9 1/2" TG(8,L)S060A10MP11 60 48 80.0 1 25-55 190 1/3 3.8 1 9 x 8 15 5.6 1 1/2" TG(8,L)S060Al2MP11 60 48 80.0 30-60 190 1/3 4.8 11 x 8 15 6.6 1/2" TG(8,L)S080B12MP11 80 64 80.0 35-65 190 1/3 4.8 11 x 8 15 7.1 1/2" TG(8,L)S080C16MP11 80 64 80.0 25-55 190 1/2 7.0 11 x 10 15 9.3 1/2" TG(8,L)SO8OC22MP11 80 64 80.0 25-55 190 1 14.1 11 x 11 20 16.4 1/2" TG(8,L)S100B12MP11 100 80 80.0 40-70 190 1/3 4.8 9 x 8 15 7.1 1/2" TG(8,L)S100C16MP11 100 80 80.0 1 35-65 190 1/2 7.0 1 11 x 10 15 9.3 1/2" TG(8,L)S100C20MP11 100 80 80.0 25-55 190 1 14.1 11 x 11 20 16.4 1/2" TG8S120C16MP11 120 96 80.0 40-70 190 1/2 7.0 11 x 10 15 9.2 1/2" TG(8,L)S120C20MP11 120 96 80.0 30-60 190 1 1 14.1 11 x 11 20 16.3 1/2" TG8S130D20MP11 130 104 80.0 35-65 190 1 14.1 11 x 11 20 16.3 1/2" Nominal external static pressure is 0.50"w.c.at furnace outlet ahead of cooling coils. Annual Fuel Utilization Efficiency(AFUE)numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code(NFPA-70-latest edition)and all local codes. 2 Johnson Controls Unitary Products 363658-CTG-1-1018 HORIZONTAL SIDEWALL VENTING Recommended Filter Sizes For applications where vertical venting is not possible, the only Cabinet Side Bottom approved method of horizontal venting is the use of an auxiliary CFM Size (in) (in) power vent.Auxiliary power venters must be approved by CSA, 800 A 16 x 25 14 x 25 UL, or other recognized safety agencies. Follow all application and installation details provided by the manufacturer of the 1000 A 16 x 25 14 x 25 power vent. 1200 A 16 x 25 14 x 25 FILTER PERFORMANCE 1200 B 16 x 25 16 x 25 1600 B 16 x 25 16 x 25 The airflow capacity data published in the "Blower Perfor- 1600 C 16 x 25 20 x 25 mance" tables shown represents blower performance WITH- 2000 C (2) 16 x 25 20 x 25 OUT filters. 2200 C (2)16 x 25 20 x 25 All applications of these furnaces require the use of field 2000 D (2)16 x 25 22 x 25 installed air filters. All filter media and mounting hardware or provisions must be field Installed external to the furnace cabl- 1. Air velocity through throwaway type filters may not exceed 300 feet per min- uteattempt (91.4 m/min).All velocities over this require the use of high velocity fil- e Y ters. 2. Do not exceed 1800 CFM using a single side return and a 16x25 filter.For CFM greater than 1800,you may use two side returns or one side and the bottom or one return with a transition to allow use of a 20x25 filter. Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturer's recom- mendation and a transition is used to allow use on a 20x25 fil- ter. Unit Clearances to Combustibles(All dimensions in inches,and all surfaces identified with the unit in an upflow configuration) Application Top Front Rear Left Right Flue Floor/ Closet Alcove Attic Line Side Side Bottom Contact Upflow 1 6 0 0 3 6 Combustible Yes Yes Yes No Upflow B-Vent 1 3 0 0 0 1 Combustible Yes Yes Yes No Downflow 1 6 0 0 3 6 11 Yes Yes Yes No Downflow B-Vent 1 3 0 0 0 1 11 Yes Yes Yes No Horizontal 1 6 0 0 3 6 Combustible No Yes Yes Yes2 Horizontal B-Vent 1 3 0 0 0 1 Combustible No Yes Yes Yes2 1. Special floor base or air conditioning coil required for use on combustible floor. 2. Line contact only permitted between lines formed by the intersection of the rear panel and side panel(top in horizontal position)of the furnace jacket and building joists,studs or framing. Johnson Controls Unitary Products 3 363658-CTG-1-1018 ACCESSORIES Masonry Chimney Kits-This accessory kit allows upflow 80% Propane (LP) Conversion Kit -This accessory conversion kit models to be vented into a tile-lined masonry chimney. may be used to convert natural gas units for propane(LP)oper- S1-1 CK0604-All 80% Non-modulating Models ation. Combustible Floor Base Kit -These kits are required to pre- S1-1 NP0347-AII Models except 130,000 BTU input vent potential overheating situations when the furnaces are S1-1 NP0501 - 130,000 BTU input only. installed in downflow applications directly onto combustible flooring material. These kits are also required in any applica- LP Stainless Steel Burner Kit-This accessory conversion kit tions where the furnace is installed in a downflow configuration may be used to convert existing burners to stainless steel burn- without an indoor coil and where the combustible floor base kit ers for LP use only. provides access for combustible airflow. S 1-32926889000-AII LP Models S1-1CB0514- For 14-1/2"cabinets Natural (NAT) Gas Stainless Steel Burner Kit - This acces- S1-1CB0517- For 17-1/2"cabinets sory kit may be used to replace existing burners with stainless S1-1CB0521 - For 21"cabinets steel burners for NAT gas use only. S1-1CB0524- For 24"cabinets S1-32924441000-AII NAT gas Models High Altitude Pressure Switches - For installation where the Side Return Filter Racks - The S1-1SR0200 Kit accommo- altitude is less than 5,000 feet, it is not required that the pres- dates a 1", 2"or 4"filter.The S1-1 SR0402 Kit accommodates a sure switch be changed. For altitudes above 5,000 feet, see kits 1"filter only. below. S1-1SR0200-All Models S1-1PS3301 -040, 060, 080, 120 S1-1SR0402-All Models S1-1PS3302- 100, 130 Bottom Return Filter Racks -The S1-1BR05* series are gal- Thermostats - Compatible thermostat controls are available vanized steel filter racks.The S1-1 BR06*series are pre-painted through accessory sourcing. For optimum performance, these steel filter racks to match the appearance of the furnace cabi- outdoor units are fully compatible with our Coleman Touch- net. The S1-1BR05* and S1-1BR06* series filter racks accom- screen Thermostats available through Source1. For more infor- modate a 1", 2"or 4"filter. mation, see the thermostat section of the Product Equipment S1-1BR0514 or S1-1BR0614-For 14-1/2"cabinets Catalog. S1-1BR0517 or S1-1BR0617-For 17-1/2"cabinets S1-1BR0521 or S1-1BR0621 -For 21"cabinets S1-1BR0524 or S1-1BR0624-For 24"cabinets 4 Johnson Controls Unitary Products 363658-CTG-1-1018 Blower Performance CFM -Any Position(without filter)-Bottom Return Bottom Airflow Data(SCFM) Models Speed Ext.Static Pressure(in.H2O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 High 966 923 874 804 717 566 386 121 NA NA TG(8,L)S040A08MP11 Medium High 813 782 743 687 605 464 280 118 NA NA Medium Low 745 706 667 619 545 413 205 NA NA NA Low 684 655 614 565 489 342 171 NA NA NA High 1292 1230 1160 1088 1004 891 760 476 129 129 Medium High 1203 1157 1105 1035 942 846 728 485 133 129 TG(8,L)S060A10MP11 Medium Low 1043 1010 962 905 823 705 491 305 124 123 Low 869 845 811 772 708 579 438 178 145 125 High 1358 1341 1319 1303 1275 1238 1190 1130 1062 943 Medium High 1097 1083 1075 1064 1042 1024 997 962 906 821 TG(8,L)S060Al2MP11 Medium Low 935 928 920 899 872 840 809 771 731 659 Low 800 779 763 736 711 687 657 622 584 529 High 1329 1307 1285 1247 1195 1143 1091 1027 927 806 Medium High 994 1004 1008 984 970 941 893 839 773 669 TG(8,L)S080B12MP11 Medium Low 786 790 782 781 761 743 726 685 630 540 Low 655 654 647 629 620 594 560 524 469 399 High 1881 1822 1783 1696 1602 1539 1465 1394 1267 1130 TG(8,L)S080C16MP11 Medium High 1553 1535 1492 1456 1408 1343 1279 1226 1113 1014 Medium Low 1312 1286 1288 1260 1205 1143 1091 1029 966 841 Low 1169 1166 1128 1098 1069 1032 987 909 835 747 High 2811 2725 2638 2540 2448 2339 2224 2111 1974 1831 TG(8,L)S080C22MP11 Medium High 2234 2233 2147 2092 2042 1974 1907 1820 1705 1575 Medium Low 1722 1716 1690 1681 1603 1553 1489 1426 1335 1241 Low 1396 1375 1348 1325 1263 1200 1150 1120 1052 965 High 1314 1318 1292 1265 1223 1177 1119 1051 971 890 Medium High 1010 1004 1003 995 992 956 914 857 798 721 TG(8,L)S100B12MP11 Medium Low 812 805 796 786 777 754 727 685 626 560 Low 661 659 644 623 614 605 568 532 482 399 High 2069 2014 1956 1885 1820 1748 1668 1577 1468 1362 TG(8,L)S100C16MP11 Medium High 1662 1656 1639 1608 1586 1544 1491 1421 1338 1204 Medium 1368 1371 1377 1376 1367 1334 1295 1250 1188 1104 Low 1016 1014 1018 1030 1012 996 975 944 898 852 High 2893 2774 2687 2589 2478 2376 2255 2120 1978 1824 TG(8,L)S100C20MP11 Medium High 2272 2243 2204 2169 2086 2018 1940 1842 1743 1602 Medium Low 1765 1752 1737 1718 1674 1619 1561 1493 1437 1312 Low 1425 1380 1409 1378 1307 1274 1226 1180 1113 1025 High 1752 1724 1702 1664 1600 1542 1454 1372 1264 1119 TG8S120C16MP11 Medium High 1469 1449 1453 1420 1382 1344 1269 1197 1118 1022 Medium Low 1248 1235 1226 1207 1179 1133 1077 992 922 841 Low 1076 1076 1046 1025 1002 968 927 869 784 707 High 2701 2620 2533 2429 2338 2227 2112 1993 1861 1706 TG(8,L)S120C20MP11 Medium High 2125 2083 2046 1994 1955 1901 1857 1737 1621 1497 Medium Low 1664 1664 1647 1619 1580 1555 1468 1392 1332 1226 Low 1358 1339 1330 1318 1286 1235 1185 1141 1060 938 High 2823 2714 2613 2507 2399 2282 2170 2042 1908 1761 TG8S130D20M P11 Medium High 2242 2188 2154 2102 2045 1970 1887 1792 1673 1537 Medium Low 1805 1791 1738 1725 1675 1623 1567 1487 1394 1256 Low 1425 1 1427 1403 1335 1324 1280 1236 1176 1103 996 1. Airflow expressed in standard cubic feet per minute(CFM). 2. Motor voltage at 115 V. Johnson Controls Unitary Products 5 Blower Performance CFM -Any Position (without filter)-Left Side Return Left Side Airflow Data(SCFM) Models Speed Ext.Static Pressure(in.H2O) 0.1 1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 High 994 971 942 899 829 725 419 120 NA NA TG(8,L)SO40A08MP11 Medium High 824 804 777 739 675 489 350 361 NA NA Medium Low 757 733 694 659 575 444 399 NA NA NA Low 707 684 641 604 495 397 282 NA NA NA High 1371 1323 1251 1169 1086 971 843 521 NA NA TG(8,L)S060A10MP11 Medium High 1249 1207 1158 1098 1018 921 669 503 NA NA Medium Low 1059 1026 997 949 889 793 582 420 NA NA Low 854 836 809 775 717 576 464 216 NA NA High 1406 1401 1394 1379 1338 1304 1261 1202 1135 1040 TG(8,L)S060Al2MP11 Medium High 1129 1126 1107 1094 1076 1047 1010 966 921 843 Medium Low 970 947 933 916 890 863 827 789 741 668 Low 834 809 797 768 740 710 677 634 586 534 High 1274 1285 1255 1239 1207 1158 1111 1049 979 830 TG(8,L)S080B12MP11 Medium High 975 974 968 960 948 923 879 823 756 672 Medium Low 777 771 772 762 752 734 695 651 604 529 Low 647 634 623 610 602 588 552 506 457 381 High 1825 1781 1746 1695 1641 1587 1521 1429 1330 1184 TG(8,L)S080C16MP11 Medium High 1516 1493 1482 1464 1442 1411 1343 1275 1192 1035 Medium 1294 1297 1271 1238 1187 1120 1083 1028 979 851 Low 1126 1115 1095 1049 1027 996 957 929 840 742 High 2972 2863 2769 2671 2571 2465 2352 2227 2095 1950 TG(8,L)S080C22MP11 Medium High 2173 2146 2103 2082 2036 1966 1904 1827 1738 1621 Medium Low 1670 1667 1647 1618 1585 1549 1492 1408 1350 1238 Low 1371 1339 1317 1284 1259 1199 1147 1085 1024 928 High 1258 1278 1283 1259 1240 1204 1149 1073 1015 897 TG(8,L)S100B12MP11 Medium High 986 995 1011 1003 962 935 913 861 808 738 Medium Low 793 786 786 783 780 750 733 702 627 567 Low 667 653 640 629 604 583 558 519 469 427 High 2009 1994 1933 1893 1836 1763 1691 1606 1508 1389 TG(8,L)S100C16MP11 Medium High 1523 1506 1521 1490 1466 1435 1393 1326 1241 1119 Medium Low 1230 1249 1245 1230 1218 1195 1161 1120 1039 949 Low 1126 1115 1095 1049 1027 996 957 929 840 742 High 2964 2886 2794 2707 2623 2522 2415 2281 2149 2012 TG(8,L)S100C20MP11 Medium High 2192 2178 2150 2109 2098 2007 1956 1888 1795 1671 Medium Low 1699 1695 1706 1632 1612 1568 1519 1460 1392 1293 Low 1361 1356 1337 1304 1267 1243 1191 1149 1077 994 High 1789 1774 1738 1702 1665 1608 1514 1431 1343 1205 TG8S120C16MP11 Medium High 1451 1445 1431 1413 1394 1362 1312 1235 1149 1037 Medium 1202 1210 1266 1252 1226 1191 1082 1028 950 852 Low 1063 1050 1033 1010 1007 982 941 889 845 778 High 2828 2768 2699 2612 2524 2423 2308 2219 2118 1982 TG(8,L)S120C20MP11 Medium High 2085 2073 2042 2029 1967 1896 1893 1816 1717 1635 Medium Low 1620 1631 1636 1593 1567 1557 1520 1476 1407 1263 Low 1322 1311 1302 1271 1241 1201 1162 1101 1042 979 High 2958 2862 2758 2662 2553 2447 2328 2203 2056 1893 TG8S130D20MP11 Medium High 2191 2182 2157 2092 2085 1997 1932 1844 1741 1608 Medium Low 1737 1738 1713 1 1691 1675 1590 1531 1467 1389 1276 Low 1404 1394 1380 1 1355 1327 1276 1220 1163 1095 1013 1. Airflow expressed in standard cubic feet per minute(CFM). 2. Return air is through side opposite motor(left side). 3. Motor voltage at 115 V. 4. Airflow through across motor side(right side)may be slightly less than the data shown above. Subject to change without notice.Published in U.S.A. 363658-CTG-1-1018 Copyright©2018 By Johnson Controls, Inc.All rights reserved. Supersedes:363658-CTG-H-0616 York International Corp. 5005 York Drive Norman,OK 73069 RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 18230 Champions Dr Project Description:Gielskei furnace Owner: Stephanie Gielskei Address. 18230 Champions Dr City. Arlington State Wa Zip Code: 98223 Phone. 425-681-4885 Email:NA Applicant: Paragon Heating and Home Comfort Solutions Address: PO Box 798 City: Marysville State.Wa Zip Code: 98270 Phone. 360-658-9500 Email. info@paragonheating.com CONTRACTOR INFORMATION Contractor Name:Paragon Heating and Home Comfort Solutions Address: PO Box 798 City: Marysville StateWa Zip Code: 98223 License Number: PARAGHC8632A Expiration. 5/1/2020 Phone: 360-658-9500 Email:info@paragonheating.com STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #TG85080B12MP11 AFUE80% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances L07 , I � Applicant Signature: d5a513be"a92O�tlb81'e`1e6' Date: 09/06/2019 Applicant Printed Name: Jeana Brennan I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 CITY OF ARLINGTON lco 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 11, PHONE; (360) 403-3551 `.+BUILDINC PERMIT Address: 18230 Champions Dr Permit#:2776 Parcel#:00874400008500 Valuation:.00 OWNER APPLICANT CONTRACTOR Name:GIELSKI RUSSELL L Name:Paragon Heating&Comfort Solutions Name:Paragon Heating Address: 18230 CHAMPIONS DR Address:PO Box 798 Address:P.O.Box 798 City,State Zip:ARLINGTON•WA 98223 City.State Zip:Marysville,WA 98270 City,State Zip:Marysville,WA 98270 Phone: Phone:360-658-9500 Phone:360-658-9500 LIC: EXP: MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Paragon Heating Name: Address:PO Box 798 Address: City,State,Zip:Marysville,WA 98270 City,State,Zip: Phone:360-658-9500 Phone: LIC#:PARAGHC863KA EXP: 05/01/2020 LIC#: EXP: l`< J©IR h?ESCRIPTiON PERMIT TYPE: Residential Mechanical CODE:YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD. ._ PERIVIIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY. NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 1827 THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS%HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL.INSPECTION HAS BEEN MADE AND APPROVAL.OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC IOARCI 10. A LWTA.X1",q0_T4CF Sales tax rclatme to construction anQ,constntstiiom materials th City of Arlington must be reported on your sales tax return form and c+dc Arl on�31Q1 ll IG� 9/10/19 gnature Print Name Date aced By Date CONDITIONS Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS SIDEWALKS.DRIVEWAYS,MAROUEES ETC)WILL REQUIRE SEPARATE PERMISSION- PERMIT FEES Date Description Fee Amount 09/10/2019 Furnace S25.00 09/10/2019 Mechanical Permit Base Fee $25.00 09/10/2019 Processing/Technology Fee $25.00 Total Due: S75.00 Total Payment: $0,00 Balance Due: S75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 2776 Permit Date: 09/10/19 Project Name: Gielskei Applicant Name: Paragon Heating& Comfort Solutions Applicant Address: PO Box 798 City, State, Zip: Marysville, WA 98270 Contact: Phone: 360-658-9500 Email: info@paragonheating.com Permit Type: Residential Mechanical Site Address: 18230 Champions Dr Valuation: 0.00 Status: Applied Permit Issued: Permit Expires: Square Feet: 0 Type of Construction/Occupancy Type: Residential Mechanical Number of Stories: 0 Proposed Use: Install furnace MIC/Opportunity Zone: Status: IN PROCESS Property Parcel# Address Legal Description Owner Name Owner Phone Zoning GIELSKI RUSSELL 116 Common Wall 00874400008500 18230 CHAMPIONS DR L Single Family Residence Contractors Contractor Primary Contact Phone Address Contractor Type License License# Paragon Heating Jeana Brennan 360-658-9500 P.O.Box 798 CONTRACTOR Labor&Industries PARAGHC863KA Fees Fee Description Notes Amount Furnace 322.10.00.00 $25.00 Mechanical Permit Base Fee 322.10.00.00 $25.00 Processing/Technology Fee 341.43.00.02 $25.00 Total $75.00 Uploaded Files Date File Name 09/10/2019 5587925-18230 attachments CO15031000017664944 OMjLHd8WRwgRDOa7gkad TG8S.pdf 09/10/2019 5587924-18230 Residential Mechanical DAIAgdVIOtMiH.Rif RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION, Project Address:18230 Champions Dr Project Description:Gielskei furnace Owner: Stephanie Gielskei Address: 18230 Champions Dr City: Arlington State.'Va Zip Code: 98223 Phone: 425-681-4885 Email:NA Applicant: Paragon Heating and Home Comfort Solutions Address: PO Box 798 City: Marysville State Wa Zip Code: 98270 Phone: 360-658-9500 Email: info@paragonheating.com CONTRACTOR INFORMATION Contractor Name:Paragon Heating and Home Comfort Solutions Address: PO Box 798 City Marysville StateWa Zip Code: 98223 License Number:PARAGHC8632A Expiration: 5/1/2020 Phone:360-658-9500 Email:info@paragonheating.com STAFF USE ON Y Received Permit#: �L� 2-'1"ZlP Accepted by: _ Date: SFP 0 6 2019 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223 • Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #TG85080B12MP11 AFUE80% ❑ Heat Pump Model # AFUE _ HSPE_ ❑ AC Unit Model # SEER Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable.- Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shutoff valve is required within 6 feet of all appliances ,6£etia�ccztiz Applicant Signature: _.. � Date: 09/06/2019 Applicant Printed Name: Jeana Brennan I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 363658-CTG-1-1018 DESCRIPTION These compact units employ induced combustion, reliable hot MIRGLIM11 surface ignition and high heat transfer aluminized tubular heat AL exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for �- downflow applications HEATING & AIR CONDITIONING These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room, or garage and TECHNICAL GUIDE are also ideal for commercial applications.All units are factory GAS-FIRED RESIDENTIAL assembled, wired and tested to assure safe dependable and SINGLE STAGE MULTI-POSITION economical installation and operation. GAS FURNACES These units are Category I listed and may be common vented STANDARD & Low NOx MODELS with another gas appliance as allowed by the National Fuel Gas Code. MODELS: TG8S / TGLS FEATURES NATURAL GAS Easily applied in upflow, horizontal left or right,or downflow 40-130 MBH INPUT installation with minimal conversion necessary. • Compact,easy to install, ideal height 33"tall cabinet • Blower-off delay for cooling SEER improvement. • Easy access to controls to connect power/control wiring. • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation. • Low unit amp requirement for easy replacement application. • Single wire twinning or staging feature available. All models are convertible to use propane(LP)gas ! Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability. • 100%shut off main gas valve for extra safety • 4 speed, direct drive PSC motor. • 24V,40 VA control transformer and blower relay supplied for add-on cooling. • Hi-tech tubular aluminized steel primary heat exchanger • Timed on, adjustable off blower capability for maximum com- fo rt CERTIFIED- Blower door safety switch. • Low NOx models have been designed to meet specific code ('POWA90 requirements y t�RL"Ga'CV)c"", Airflow leakage less than 1%of total airflow at duct perfor- �, Iso 9001 mance testing conditions. Certified Quality �- :I Management system No knockouts to deal with, making installation easier "��"° Movable duct connector flanges for application flexibility. Due to continuous product improvement,specifications Quiet inducer operation. are subject to change without notice. Inducer rotates for easy conversion of venting options. Visit us on the web at www.york.com Fully supported blower assembly for easy access and Additional rating information can be found at removal of blower. www.ahridirectory.or External air filters used for maximum flexibility in meeting customers IAQ needs. WARRANTY Venting applications-may be installed as a common vent 20-year limited warranty on the heat exchanger. with other gas-fired appliances or use a masonry chimney. 10-year heat exchanger warranty on commercial applications. 1/4 turn knobs provided for easy door removal. Standard 5-year limited Parts warranty. Extended 10-year limited parts warranty when product is registered online within 90 days of purchase for replace- ment or closing for new home construction. Received FOR DISTRIBUTION USE ONLY-NOT TO BE USED AT POINT OF RETAIL SALE SEP 0 6 2019 117 �� 'V 363658-CTG-1-1018 LEFT SIDE Vent Connection FRONT RIGHT SIDE Outlet - Electrical ' Entry O ' Electrical Vent Entry Connection o Outlet CA Gas Pipe Gas Pipe Entry Entry m D 33" �� - 23" --� r � o (1) m r �.._ Thermostat CD Thermostat 4 Wiring Wiring 14" L J Il J 28.5" 1 I l+ A ►I -29.5" 4"Diameter 5'-,-I• 24 38 Vent Connection Outlet �5 El B 20" 24.25" ►� SUPPLY END RETURN END Cabinet and Duct Dimensions Nominal Cabinet Cabinet Dimensions(Inches) Approximate Models Operating Weights CFM(m3/min) Size A B C Lbs TG(8,L)SO40A08MP11 800 A 14 1/2 13 3/8 10.3 89 TG(8,L)S060A10MP11 1000 A 14 1/2 13 318 10.3 91 TG(8,L)S060Al2MP11 1200 A 14 1/2 13 3/8 10.3 94 TG(8,L)S080B12MP11 1200 B 17 1/2 16 3/8 11.8 103 TG(8,L)S080C16MP11 1600 C 21 19 7/8 13.6 114 TG(8,L)S080C22MP11 2200 C 21 19 7/8 13.6 119 TG(8,L)S100B12MP11 1200 B 17 1/2 16 3/8 11.8 108 TG(8,L)S100C16MP11 1600 C 21 19 7/8 13.6 118 TG(8,L)S100C20MP11 2000 C 21 19 7/8 13.6 122 TG8S120C16MP11 1600 C 1 21 19 7/8 15.8 123 TG(8,L)S120C20MP11 2000 C 21 19 7/8 15.8 129 TG8S130D20MP11 2000 D 24 1/2 23 3/8 17,5 135 Ratings&Physical/Electrical Data Air Temp. Max.Outlet Blower Recommended Gas Pipe Input Output AFUE Blower Fuse or Circuit Total Unit p Models Rise Air Temp Size BreakerAmps Amps Connection, MBH MBH % °F °F HP Amps Inches Amps NPT TG(8,L)SO40A08MP11 40 32 80.0 25-55 190 1/5 2.1 9 x 8 15 3.9 1/2" TG(8,L)S060A10MP11 60 48 80.0 25-55 190 1/3 3.8 9 x 8 15 5.6 1/2" TG(8,L)S060Al2MP11 60 48 80.0 30-60 190 1/3 4.8 11 x 8 15 6.6 1/2" TG(8,L)S080B12MP11 80 64 80.0 35-65 190 1/3 4.8 11 x 8 15 7.1 1/2" TG(8,L)S080C16MP11 80 64 80.0 25-55 190 1/2 7.0 11 x 10 15 9.3 1/2" TG(8,L)S080C22MP11 80 64 80.0 25-56 190 1 14.1 11 x 11 20 16.4 1/2" TG(8,L)S100B12MP11 100 80 80.0 40-70 190 1/3 4.8 9 x 8 15 T1 1/2" TG(8,L)S100C16MP11 100 80 80.0 35-65 190 1/2 7.0 11 x 10 15 9.3 1/2" TG(8,L)S100C20MP11 100 80 80.0 25-55 190 1 14.1 11 x 11 20 16.4 1/2" TG8S120C16MP11 120 96 80.0 40-70 190 1/2 7.0 11 x 10 15 9.2 1/2" TG(8,L)S120C20MP11 120 96 800 30-60 190 1 14.1 11 x 11 1 20 16.3 1/2" TG8S130D20MP11 1 130 1 104 80.0 35-65 190 1 14.1 11 x 11 20 16.3 1/2" Nominal external static pressure is 0.50"w.c at furnace outlet ahead of cooling coils. Annual Fuel Utilization Efficiency(AFUE)numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code(NFPA-70-latest edition)and all local codes 2 Johnson Controls Unitary Products 363658-CTG-1-1018 HORIZONTAL SIDEWALL VENTING Recommended Filter Sizes For applications where vertical venting is not possible, the only Cabinet Side Bottom approved method of horizontal venting is the use of an auxiliary CFM Size (in) (in) power vent.Auxiliary power venters must be approved by CSA, 800 A 16 x 25 14 x 25 UL, or other recognized safety agencies. Follow all application and installation details provided by the manufacturer of the 1000 A 16 x 25 14 x 25 power vent. 1200 A 16 x 25 14 x 25 FILTER PERFORMANCE 1200 B 16 x 25 16 x 25 The airflow capacity data published in the "Blower Perfor- 1600 B 16x25 16x251600 C 16 x 25 20 x 25 mance" tables shown represents blower performance WITH- OUT filters. 2000 C (2)16 x 25 20 x 25 2200 C (2)16 x 25 20 x 25 All applications of these furnaces require the use of field 2000 D (2)16 x 25 22 x 25 installed air filters. All filter media and mounting hardware or provisions must be field installed external to the furnace cabi- 1 Air velocity through throwaway type filters may not exceed 300 feet per min- uteattempt (91 4 m/min).All velocities over this require the use of high velocity fil- e Y ters. 04 2 Do not exceed 1800 CFM using a single side return and a 16x25 filter.For CFM greater than 1800,you may use two side returns or one side and the bottom or one return with a transition to allow use of a 20x25 filter. Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturers recom- mendation and a transition is used to allow use on a 20x25 fil- ter. Unit Clearances to Combustibles(All dimensions in inches,and all surfaces identified with the unit in an upflow configuration) Application Top Front Rear Left Right Flue Floor/ Closet Alcove Attic Line Side Side Bottom Contact Upflow 1 6 0 0 3 6 Combustible Yes Yes Yes No Upflow B-Vent 1 3 0 0 0 1 Combustible Yes Yes Yes No Downflow 1 6 0 0 3 6 11 Yes Yes Yes No Downflow B-Vent 1 3 0 0 0 1 11 Yes Yes Yes No Horizontal 1 6 0 0 3 6 Combustible No Yes Yes Yes2 Horizontal B-Vent 1 3 0 0 0 1 Combustible No Yes Yes Yesz 1 Special floor base or air conditioning coil required for use on combustible floor. 2. Line contact only permitted between lines formed by the intersection of the rear panel and side panel(top in horizontal position)of the furnace jacket and building joists,studs or framing. Johnson Controls Unitary Products 3 363658-CTG-1-1018 ACCESSORIES Masonry Chimney Kits-This accessory kit allows upflow 80% Propane (LP)Conversion Kit-This accessory conversion kit models to be vented into a tile-lined masonry chimney. may be used to convert natural gas units for propane(LP)oper- S1-1CK0604-All 80% Non-modulating Models ation. Combustible Floor Base Kit-These kits are required to pre- S1-1NP0347-All Models except 130,000 BTU input vent potential overheating situations when the furnaces are S1-1 NP0501 -130,000 BTU input only. installed in downflow applications directly onto combustible flooring material. These kits are also required in any applica- LP Stainless Steel Burner Kit-This accessory conversion kit tions where the furnace is installed in a downflow configuration may be used to convert existing burners to stainless steel burn- without an indoor coil and where the combustible floor base kit ers for LP use only. provides access for combustible airflow. S 1-32926889000-AII LP Models S1-1CB0514-For 14-1/2"cabinets Natural (NAT) Gas Stainless Steel Burner Kit -This acces- S1-1CB0517-For 17-1/2"cabinets sory kit may be used to replace existing burners with stainless S1-1CB0521 -For 21"cabinets steel burners for NAT gas use only. S1-1CB0524-For 24"cabinets S1-32924441000-All NAT gas Models High Altitude Pressure Switches - For installation where the Side Return Filter Racks - The S1-1SR0200 Kit accommo- altitude is less than 5,000 feet, it is not required that the pres- dates a 1",2"or 4"filter.The S1-1 SR0402 Kit accommodates a sure switch be changed. For altitudes above 5,000 feet,see kits 1"filter only. below. S1-1SR0200-AII Models S1-1PS3301 -040, 060, 080, 120 S1-1SR0402-All Models S1-1 PS3302-100, 130 Bottom Return Filter Racks -The S1-1BR05*series are gal- Thermostats - Compatible thermostat controls are available vanized steel filter racks.The S1-1 BR06*series are pre-painted through accessory sourcing For optimum performance, these steel filter racks to match the appearance of the furnace cabi- outdoor units are fully compatible with our Coleman Touch- net The S1-1 BR05* and S1-1 BR06* series filter racks accom- screen Thermostats available through Source1. For more infor- modate a 1", 2"or4"filter. mation, see the thermostat section of the Product Equipment S1-16R0514 or S1-1BR0614-For 14-1/2"cabinets Catalog. S1-1 BR0517 or S1-1 BR0617-For 17-1/2"cabinets S1-1 BR0521 or S1-1 BR0621 -For 21"cabinets S1-1 BR0524 or S1-1 BR0624-For 24"cabinets 4 Johnson Controls Unitary Products 363658-CTG-1-1018 Blower Performance CFM-Any Position(without filter)-Bottom Return Bottom Airflow Data(SCFM) Models Speed Ext.Static Pressure(in.H2O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 High 966 923 874 804 717 566 386 121 NA NA TG(8,QSO40AO8MP11 Medium High 813 782 743 687 605 464 280 118 NA NA Medium Low 745 706 667 619 545 413 205 NA NA NA Low 684 665 614 565 489 342 171 NA NA NA High 1292 1230 1160 1088 1004 891 760 476 129 129 TG(8,L)SO6OA1OMP11 Medium High 1203 1157 1105 1035 942 846 728 485 133 129 Medium Low 1043 1010 962 905 823 705 491 305 124 123 Low 869 845 811 772 708 579 438 178 145 125 High 1358 1341 1319 1303 1275 1238 1190 1130 1062 943 TG(8,L)S06OAl2MP11 Medium High 1097 1083 1075 1064 1042 1024 997 962 906 821 Medium Low 935 928 920 899 872 840 809 771 731 659 Low 800 779 763 736 711 687 657 622 584 529 High 1329 1307 1285 1247 1195 1143 1091 1027 927 806 TG(8,L)SO8OB12MP11 Medium High 994 1004 1008 984 970 941 893 839 773 669 Medium Low 786 790 782 781 761 743 1 726 685 630 540 Low 655 654 647 629 620 594 560 524 469 399 High 1881 1822 1783 1696 1602 1539 1465 1394 1267 1130 TG(8,L)SO8OC16MP11 Medium High 1553 1535 1492 1456 1408 1343 1279 1226 1113 1014 Medium Low 1312 1286 1288 1260 1205 1143 1091 1029 966 841 Low 1169 1166 1128 1098 1069 1032 987 909 835 747 High 2811 2725 2638 2540 2448 2339 2224 2111 1974 1831 TG(8,L)S08OC22MP11 Medium High 2234 2233 2147 2092 2042 1974 1907 1820 1705 1575 Medium Low 1722 1716 1690 1681 1603 1553 1489 1426 1335 1241 Low 1396 1375 1348 1325 1263 1200 1150 1120 1052 965 High 1314 1318 1292 1265 1223 1177 1119 1051 971 890 TG(8,L)S100B12MP11 Medium High 1010 1004 1003 995 992 956 914 857 798 721 Medium Low 812 805 796 786 777 754 727 685 626 560 Low 661 659 644 623 614 605 568 532 482 399 High 2069 2014 1956 1885 1820 1748 1668 1577 1468 1362 TG(8,L)S100C16MP11 Medium High 1662 1656 1639 1608 1586 1544 1491 1421 1338 1204 Medium 1368 1371 1377 1376 1367 1334 1295 1250 1188 1104 Low 1016 1014 1018 1030 1012 996 975 944 898 852 High 2893 2774 2687 2589 2478 2376 2255 2120 1978 1824 TG(8,L)S100C20MP11 Medium High 2272 2243 2204 2169 2086 2018 1940 1842 1743 1602 Medium Low 1765 1752 1137 1718 1674 1619 1561 1493 1437 1312 Low 1425 1380 1409 1378 1307 1274 1226 1180 1113 1025 High 1752 1724 1702 1664 1600 1542 1454 1372 1264 1119 TG8S12OC16MP11 Medium High 1469 1449 1453 1420 1382 1344 1269 1197 1118 1022 Medium Low 1248 1235 1226 1207 1179 1133 1077 992 922 841 Low 1076 1076 1046 1025 1002 968 927 869 784 707 High 2701 2620 2533 2429 2338 2227 2112 1993 1861 1706 TG(8,QS120C20MP11 Medium High 2125 2083 2046 1994 1955 1901 1857 1737 1621 1497 Medium Low 1664 1664 1647 1619 1580 1555 1468 1392 1332 1226 Low 1358 1339 1330 1318 1286 1235 1185 1141 1060 938 High 2823 2714 2613 2507 2399 2282 2170 2042 1908 1761 TG8S13OD20MP11 Medium High 2242 2188 2154 2102 2045 1970 1887 1792 1673 1537 Medium Low 1805 1791 1738 1725 1675 1623 1567 1487 1394 1256 Low 1425 1427 1 1403 1335 1324 1280 1236 1176 1103 996 1 Airflow expressed in standard cubic feet per minute(CFM) 2. Motor voltage at 115 V. Johnson Controls Unitary Products 5 Blower Performance CFM-Any Position(without filter)-Left Side Return Left Side Airflow Data(SCFM) Models Speed Ext.Static Pressure(in.H2O) 0.1 1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 High 994 971 942 899 829 725 419 120 NA NA TG(8,L)SO40A08MP11 Medium High 824 804 777 739 675 489 350 361 NA NA Medium Low 757 733 694 659 575 444 399 NA NA NA Low 707 684 641 604 495 397 282 NA NA NA High 1371 1323 1251 1 1169 1086 1 971 843 521 1 NA NA TG(8,L)S060A10MP11 Medium High 1249 1 1207 1158 1098 1018 921 669 503 NA NA Medium Low 1059 1026 997 949 889 793 582 420 NA NA Low 854 836 809 775 717 576 464 216 NA NA High 1406 1401 1394 1379 1338 1304 1261 1202 1135 1040 Trio i S060 ,2MP11 Medium High 1129 1126 1107 i094 1076J 1047 1010 966 921 843 �� '��.�� `�' Medium Low 970 947 933 916 890 863 827 789 741 668 Low 834 809 797 768 740 710 677 634 586 534 High 1274 1285 1255 1239 1207 1158 1111 1049 979 830 TG(8,L)S080B12MP11 Medium High 975 974 968 960 948 923 879 823 756 672 Medium Low 777 771 772 762 752 734 695 651 604 529 Low 647 634 623 610 602 588 552 506 457 381 High 1825 1781 1746 1695 1641 1587 1521 1429 1330 1184 TG(8,QS080C16MP11 Medium High 1516 1493 1482 1464 1442 1411 1343 1275 1 1192 1035 Medium 1294 1297 1271 1238 1187 1120 1083 1028 979 851 Low 1126 1115 1095 1049 1027 996 957 929 840 742 High 2972 1 2863 2769 1 2671 2571 1 2465 2352 2227 2095 1950 TG(8,L)S080C22MP11 Medium High 2173 2146 2103 2082 2036 1966 1904 1827 1738 1621 Medium Low 1670 1667 1647 1618 1585 1549 1492 1408 1350 1238 Low 1371 1339 1317 1284 1259 1199 1147 1085 1024 928 High 1258 1278 1283 1259 1240 1204 1149 1073 1 1015 897 TG(8,L)S100B12MP11 Medium High 986 995 1011 1003 962 935 913 861 808 738 Medium Low 793 1 786 786 1 783 780 750 733 702 627 567 Low 667 653 640 629 604 583 558 519 469 427 High 2009 1994 1933 1893 1836 1763 1691 1606 1508 1389 TG(8,L)S100C16MP11 Medium High 1523 1506 1521 1490 1466 1435 1393 1326 1241 1119 Medium Low 1230 1249 1245 1230 1218 1195 1161 1120 1 1039 949 Low 1126 1115 1095 1049 1027 996 957 929 840 742 High 2964 1 2886 2794 1 2707 2623 1 2522 2415 2281 2149 2012 TG(8,L)S100C20MP11 , Medium High 2192 2178 2150 2109 2098 2007 1956 1888 1795 1671 Medium Low 1699 1695 1706 1632 1612 1568 1519 1460 1392 1293 Low 1361 1356 1337 1304 1267 1243 1191 1149 1077 994 High 1789 1774 1738 1702 1665 1608 1514 1431 1 1343 1205 TGBS120C16MP11 Medium High 1451 1445 1 1431 1413 1 1394 1362 1312 1235 1149 1037 Medium 1202 1210 1266 1252 1226 1191 1082 1028 950 852 Low 1063 1050 1033 1010 1007 982 941 889 845 778 High 2828 2768 2699 2612 2524 2423 1 2308 2219 2118 1982 TG(8,L)Sl20C20MP11 Medium High 2085 2073 2042 2029 1967 1896 1893 1 1816 1717 1635 Medium Low 1620 1631 1636 1593 1567 1557 1520 1476 1407 1263 Low 1322 1 1311 1302 1 1271 1241 1201 1162 1101 1042 979 High 2958 2862 2758 2662 2553 2447 2328 2203 2056 1893 TG8S130D201Vl P11 Medium High 2191 2182 2157 2092 2085 1997 1932 1844 1741 1608 Medium Low 1737 1738 1713 1691 1675 1590 1531 1467 1389 1276 Low 1404 1394 1380 1355 1327 1276 1 1220 1163 1 1095 1013 1. Airflow expressed in standard cubic feet per minute(CFM). 2- Return air is through side opposite motor(left side). 3 Motor voltage at 115 V. 4 Airflow through across motor side(right side)maybe slightly less than the data shown above Subject to change without notice.Published in U.S.A. 363658-CTG-1-1018 Copyright©2018 By Johnson Controls,Inc All rights reserved. Supersedes:363658-CTG-H-0616 York International Corp. 5005 York Drive Norman,OK 73069 Search L&I Labor Safety&Health -1 Claims&Insurance 2 ■ ■ . Trades Washington State Depar"ent of `j Labor & industries Paragon Htg/Hm Emft Sttns LLE Owner or tradesperson PO Box 798 Principals MARYSVILLE,WA 98270 BRENNAN,JEANA A,PARTNER/MEMBER 425-252-1807 SNOHOMISH County ■ BRENNAN,SCOTT M,PARTNER/MEMBER ■ Brennan,Jeana,AGENT Doing business as Paragon Htg/Hm Cmft Sltns LLC WA UBI No. Business type 603 395 569 Limited Liability Company Governing persons JEANA BRENNAN SCOTT BRENNAN; Certifications &Endorsements License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Electrical Contractor Active. Meets current requirements. License specialties HVAC/RFRG License no. PARAGHC863KA Effective—expiration 05/01/2014—05/01/2020 Designated administrator Active. Brennan,Scott M Meets current requirements. License type License no. Electrical Administrator BRENNSM865KZ Bond RLI Ins Co $4,000.00 Bond account no. LSM0614568 Received by L&I Effective date 05/01/2014 05/01/2014 Expiration date Until Canceled Savings ............. .. No savings accounts during the previous 6 year period. License Violations I Help tis improve Infraction no. EHOUD00927 Satisfied Issue date RCW/WAC 08/27/2015 19.28.101 RCW Violation city Violation amount MARYSVILLE $100.00 Type of violation ELECTRICAL CITATION Description Class B eligible work-The Class B work permit is not valid as referenced in WAC 296- 46113-901 and WAC 296-46B-908. Workers'comp Pubt'ic Works Requirements Workplace safety and health . Y�r;rMgp.,?•.. :E►: a'_is!ov.3'nVUst7!o• U•rM!hf _alp• :q','�".:.arawa!Umo7�al,e�,,ya.^�-,�: — _. .._ � .._ ._ ... ! 1C1C35 A&A ashineton' Help us improve CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:18230 Champions Dr Permit#:2776 Parcel#:00874400008500 Valuation:.00 OWNERMM APPLICANT CONTRACTOR Name:GIELSKI RUSSELL L Name:Paragon Heating&Comfort Solutions Name:Paragon Heating Address: 18230 CHAMPIONS DR Address:PO Box 798 Address:P.O.Box 798 City,State Zip:ARLINGTON,WA 98223 City,State Zip:Marysville,WA 98270 City,State Zip:Marysville,WA 98270 Phone: Phone:360-658-9500 Phone:360-658-9500 LIC: EXP: MECHANICAL CONTRACTOR PLUMBING CONTRALTO Name:Paragon Heating Name: Address:PO Box 798 Address: City,State,Zip:Marysville,WA 98270 City,State,Zip: Phone:360-658-9500 Phone: LIC#:PARAGHC863KA EXP: 05/01/2020 LIC#: EXP: JOB DESCRIPTION I g PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. "" 9/10/19 Signature Print Name Date eased By Date CONDITIONS — Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/10/2019 Furnace $25.00 09/10/2019 Mechanical Permit Base Fee $25.00 09/10/2019 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address: 18230 Champions Dr Permit#:2776 Parcel#:00874400008500 Valuation: .00 OWNER APPLICANT CONTRACTOR Name:GIELSKI RUSSELL L Name:Paragon Heating&Comfort Solutions Name:Paragon Heating Address: 18230 CHAMPIONS DR Address:PO Box 798 Address:P.O.Box 798 City,State Zip:ARLINGTON,WA 98223 City,State Zip:Marysville,WA 98270 City,State Zip:Marysville,WA 98270 Phone: Phone:360-658-9500 Phone:360-658-9500 LIC: EXP: MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Paragon Heating Name: Address:PO Box 798 Address: City,State,Zip:Marysville,WA 98270 City,State,Zip: Phone:360-658-9500 Phone: LIC#:PARAGHC863KA EXP: 05/01/2020 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18,27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRC110. SAL . 4 O E:'Sales tax relating to construction an construction materials�'nth City of Arlington must be reported on your sales tax return form and oded Arl t onh#3IQ1. I' \, �/' �1� it✓��61 Yl 4llti k} 1( I 9/10/19 gnature Print Name Date aced By Date CONDITIONS Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS.DRIVEWAYS,MARQUEES.ETC.)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 09/10/2019 Furnace $25.00 09/10/2019 Mechanical Permit Base Fee $25.00 09/10/2019 Processing/Technology Fee $25.00 Total Due: S75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number.Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 2776 Permit Date: 09/10/19 Permit Type: RESIDENTIAL MECHANICAL Project Name: Gielskei Applicant Name: Paragon Heating & Comfort Solutions Applicant Address: PO Box 798 Applicant, City, State, Zip: Marysville,WA 98270 Contact: Phone: 360-658-9500 Email: info@paragonheating.com Scope of Work: Install furnace Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 09/11/2019 Permit Expires: Form Permit Type: Status: IN PROCESS Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning GIELSKI RUSSELL 116 Common Wall 00874400008500 18230 CHAMPIONS DR L Single Family Residence Contractors Contractor Primary Contact Phone Address Contractor Type License License# Paragon Heating Jeana Brennan 360-658-9500 P.O.Box 798 CONSTRUCTION UBI 603 395 569 CONTRACTOR Paragon Heating Jeana Brennan 360-658-9500 P.O.Box 798 CONSTRUCTION Labor CONTRACTOR Industri&es PARAGHC8632A Fees Fee Description Notes Amount Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Credit Card Service $2.25 Total $77.25 Attached Letters Date Letter Description 09/10/2019 Building Permit 09/10/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 09/11/2019 Jeana Brennan 76987449 $75.00 09/11/2019 76987449 CC Surcharge Raelynn Jones $2.25 Outstanding Balance $0.00 Uploaded Files Date File Name 09/10/2019 5587924-18230 Residential Mechanical DJk1AgdVl0tMiH.pdf 09/10/2019 5587925-18230 attachments C015031000017664944 OMjLHd8WRwgRDoa7gkad TG8S.pdf