Loading...
HomeMy WebLinkAbout17731 33RD AVE NE_BLD6713_2026 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT Wr 17731 33RD AVE NE Permit#:6713 Parcel#:00621300006700 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:GAS FURNACE SWAP Valuation:8557.00 APPLICANT CONTRACTOR OHAGEN P J CM HEATING CM HEATING INC 17731 33RD AVE NE 1500 INDUSTRY ST#200 1500 INDUSTRY ST STE 200 ARLINGTON,WA 98223-8739 EVERETT EVERETT,WA 98203 4252590550 425-259-0550 LIC:CMHEAHL7501-P EXP:06/25/2027 LIC:CMUF.AlIL751W EXP:06/17/2027 U0 605890285 EXP:06/17/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2021 STORIES: 2 CONST.TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: - PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. 9/16/25 "to/ ��G�� 09/15/2025 Applicant Signature Date Building Official Date CONDITIONS J Adhere to approved materials.Permit shall be onsite for inspections. Call for final inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations.The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction.The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. JEEW PERMIT FEES - Date Description Fee Amount 09/15/2025 Processing/Technology $25.00 09/15/2025 Inspection $75.00 09/15/2025 Forced Air Heat<_100 BTU/h $15.00 09/15/2025 Wbchanical Base $25.00 Total Due: $140.00 Total Payment: S140.00 Balance Due: $0.00 - CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whe the ryou prefer morning or afternoon INSPECTION INFORMATION I Pass/Fail RESIDENTIAL MECHANICAL APPLICATION Community and Economic Development City of Arlington• 18204 59th Ave NE -Arlington,WA 98223 •Phone(360)403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit: ❑ New Installation 0 Addition/Alteration/Repair ❑ Gas Piping 17731 33RD AVE NE $8557 Property Address: Project Valuation: Lot#: - Parcel ID No.. 00621300006700 Preferred Contact: ❑ Owner N Contractor Project Description: GAS FURNACE SWAP Owner Name: JANE O"HAGAN Home No.: 3606593291 Email Address: COffeezgreat@yahoo.com Cell No.: 17731 33RD AVE NE ARLINGTON Mailing Address: City: State: WA zip:98223 Contractor Name: CM HEATING Office No.: 4252590550 Email Address. PERMITS@CMHEATING.COM Cell No.: - Mailing Address: 1500 INDUSTRY ST#200 City: EVERETT State: WA zip: 98203 L&I Contractor License Number: CMHEAHL751 LW Expiration Date: 6/30/25 • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information ® Not Applicable ❑CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ V2" ❑ 5/s" ❑ 3/4" ❑ 1" ❑ 11h" ❑ 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: sr' ential mechanical permits will be assessed a base fee, ee per unit,and inspection fee (plan review per Table 4-8 may be required fo_ rtain permits) Type of Fixture No.of Cost per Unit Subtotal Model No. Units Additional Plan Review fees x $75.00 = Air Conditioning Units 100 Btu h x $15.00 = Air Conditioning Unit>100 Btu/h x $25.00 = Air Conditioning Unit>500 Btu/hp x $50.00 = Air Handling Units x $15.00 = Base Mechanical Fee 1 x $25.00 = $25.00 Boiler<100Btu/h>3h x $15.00 = REV03.2022 Page 1 of 3 Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan revieMbper Table 4-8 may be required forSertain permits � Boiler>1 million Btu/h<50hp x $25.00 = Boiler>1.5 million Btu/h<SOhp x $50.00 = Boiler>100Btu/h 3-15h x $15.00 = Boiler>500Btu/h 15-30hp x $25.00 = Commercial Hoods-Type I x $25.00 = Commercial Hoods-Type II x $50.00 = Diffusers x $15.00 = Dryer Ducting x $15.00 = Ductwork(drawings required) x $25.00 = Evaporative Coolers x $15.00 = Exhaust Ventilation Fans x $15.00 = Fireplace/Insert/Stove x $15.00 = Forced Air Heat<_100 Btu h 1 x $15.00 = 15 Forced Air Heat>100 Btu h x $25.00 = Gas Clothes Dryer x $15.00 = Gas Fired Air Conditioning Unit<_ 100 Btu/h x $15.00 = Gas Fired Air Conditioning Unit> 100 Btu/h x $25.00 = Gas Fired Air Conditioning Unit>500 Btu/hp x $50.00 = Gas Pi in <_5 units x $15.00 = Gas Piping for each additional unit >5 x $2.00 = Heat Exchangers x $15.00 = Heat Pump-Condensing Unit x $25.00 = Hot Water Heat Coils x $15.00 = Miscellaneous Appliance-regulated by $15.00 mechanical code,not otherwise specified x Package Units s 100 Btu >100 Btu x $25.00 $50.00 = Range/Cook top-Gas Fired x $15.00 = Refrigeration Unit<_100Btu h x $15.00 = Refrigeration Unit>100Btu h x $25.00 = Refrigeration.Unit>500Btu h x $50.00 f = Re-inspection fee x $75.00 _ Residential Range Hood x $15.00 = Unit Heaters<_ 100 Btu h x $15.00 = Unit Heaters>100 Btu/h x $25.00 = Variable Air Volume Boxes(part of Air $10.00 _ ConditioningSystem) x Wall Heaters Gas Fired x $25.00 = Water Heater-Gas Fired x $25.00 = Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above described property will be in accordance with the laws,rules and regulation of the State of Washington. SABRINA KENNARD 9/15/25 Signature Print Name Date REV2.2024 Page 2 of Amm" SAwdard., HEATING & AIR CONDITIONING Product Data Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace Upflow, Convertible to Downflow Only Horizontal Right or S9X2B040D3PSBA Horizontal Left S9X2B060D3PSBA S9X2B040U3PSBA S9X2B080D4PSBA S9X2B060U4PSBA S9X2C100D5PSBA S9X2B080U4PSBA S9X2D120D5PSBA S9X2C080U5PSBA oo O S9X2C10005PSBA S9X2D120U5PSBA 0 0 0 Note:Graphics in this document are for representation only.Actual model may differ in appearance. August 2019 12-1389-1 E-EN I���Ingersoll Rand, �c icati, �S'7 iw HEATING & AIR CONDITIONING General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P.gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control is a solid state device which continuously monitors for presence of flame when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide additional safety. QUICK HEATING Durable,cycle tested,heavy gauge tubular stainless steel primary heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower,to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS Multiport Inshot burners will give years of quiet and efficient service.All models can be converted to L.P.gas with LP conversion kit. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers,gas valve,flame control and includes self diagnostics for ease of service.Also contains dry contacts for EAC and HUM. ENERGY EFFICIENT OPERATION Furnace is certified by the manufacturer to leak 1%or less of nominal air conditioning CFM delivered when pressurized to .5"water column with all inlets,outlets,and drains sealed. AIR DELIVERY The variable speed blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. SECONDARY HEAT EXCHANGER The S-Series furnace has a special type 29-4CTI stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost. STYLING Heavy gauge steel and "wrap-around"cabinet construction is used in the cabinet with baked- on enamel finish for strength and beauty. Every orientation has at least two venting options. There are no knockouts on cabinet. FEATURES AND GENERAL OPERATION The S-Series furnace utilizes a Silicon Nitride Hot Surface Ignition system,which eliminates the waste of a constant burning pilot.The integrated system control lights the main burners upon a demand for heat from the room thermostat.Complete front service access. a. Low energy power venter b.Vent proving pressure switches. 2 12-1389-1 E-E N �c icati, �S'7 iw HEATING & AIR CONDITIONING Features and Benefits UP TO 96.0%AFUE ON S9X2 FURNACE MODELS Meets utility rebates Lowers utility bills ELECTRICALLY EFFICIENT Efficient airflow design reduces electrical energy use 34 INCH TALL Lighter,easier to move and fit into tight spaces like short basements or tight closets Works great with larger, high-efficiency coils No knockouts 3—WAY MULTI-POISE/DEDICATED DOWNFLOW 6 SKU's — Upflow/Horizontal Left/Horizontal Right 5 SKU's — Downflow Added application flexibility and reduction in specification errors AIRFLOW At least 400 CFM/ton at 0.5 in. H2O external static pressure;setup airflow options down to 290 CFM/ton REGULATORY All models are airtight; 1%or less air leakage as per ASHRAE 193 Open vestibule design provides a full 34" high open vestibule DIMENSIONS Widths are industry standard: 17.5",21",and 24.5" Depth remains approximately 28" Cabinet will be compatible with industry standard coils,as well as,other accessories INTEGRATED FURNACE CONTROL Setup/Status/Diagnostics/Digital Display No dip switches Last six errors stored Dry contact EAC and HUM connections All Molex connections; no spade terminals Low voltage labeled above and below Rain shield over IFC keeps condensate off the control TUBULAR STAINLESS STEEL PRIMARY HEAT EXCHANGER 29-4C STAINLESS STEEL SECONDARY HEAT EXCHANGER Stainless steel is a more durable,corrosive-resistant material than aluminumized steel Integrated rail system for easy access if required Reduces or eliminates need for baffles VORTICA II BLOWER, DESIGNED EXCLUSIVELY FOR THE S-SERIES FURNACE Improved airflow efficiency Durable,easy to clean,two piece housing Single piece belly band/motor arm assembly Blower deck has full-length rails for easy removal and replacement, regardless of poise THREE—WAY MULTI-POISE (UPFLOW, HORIZONTAL LEFT AND RIGHT) PLUS DEDICATED DOWNFLOW 12-1389-1 E-E N 3 71* eao S-lavdard® HEATING & AIR CONDITIONING Features and Benefits Easier to specify Shipped ready to install (no conversion kits required) Every model has at least two venting options When in horizontal,trap extends only about 2" Barbed fitting on trap at hose connection and on cabinet transition for hose has barbed fitting and clamps at both ends for leak resistance. Vent table improvements including longer vent lengths;2" pipe can be used up to 100K 4 12-1389-1 E-E N A�cao SAwd'ard® HEATING & AIR CONDITIONING Accessories Table 1. Accessories Model Number Description Use with MAYBFERCOLKITA Heat Shield Kit for B-width 4GXCB or 4MCXB Coils B width 4GXCB or 4MCXB Coils when installed with Upflow Furnace in all orientations MAYCFERCOLKITA Heat Shield Kit for C-width 4GXCC or 4MCXC Coils C width 4GXCC or 4MCXC Coils when installed with Upflow Furnace in all orientations MAYDFERCOLKITA Heat Shield Kit for D-width 4GXCD or 4MCXD Coils D width 4GXCD or 4MCXD Coils when installed with Upflow Furnace in all orientations BAYHANG Horizontal Hanging Kit All Upflow Furnaces BAYVENT200B Sidewall Vent Termination Kit All Furnaces BAYVENTCN200B Sidewall Vent Termination Kit(Canada—CPVC) All Furnaces BAYAIR30AVENTA Concentric Vent Kit All Furnaces BAYAIR30CNVENT Concentric Vent Kit(Canada—CPVC) All Furnaces BAYREDUCE Reducing Coupling(CPVC) All Furnaces BAYLIFTB Dual Return Kit(B size extension) B Cabinet Upflow Furnaces BAYLIFTC Dual Return Kit(C size extension) C Cabinet Upflow Furnaces BAYLIFTD Dual Return Kit(D size extension) D Cabinet Upflow Furnaces BAYBASE205 Downflow Subbase All Downflow Furnaces BAYFLTR206 Filter Access Door Kit(Downflow only) All Downflow Furnaces BAYSF1165AA(a) 1"SlimFit Box with MERV 4 Filter All Upflow Furnaces BAYSF1255BA 1"SlimFit Filter and Insulated Frame All Furnaces(b) FLRSF1255 1"Filter replacement(Qty 12) BAYSF1255BA BAYFLTR203 Horizontal Filter Kit B Cabinet Furnaces in Downflow/Horizontal BAYFLTR204 Horizontal Filter Kit C Cabinet Furnaces in Downflow/Horizontal BAYFLTR205 Horizontal Filter Kit D Cabinet Furnaces in Downflow/Horizontal BAYLPSS400B Propane Conversion Kit with Stainless Steel Burners All Furnaces BAYMFGH200B Manufactured/Mobile Housing Kit All Furnaces BAYCNDTRAP2A Inline Condensate Trap Kit used with Special Venting on 2" All Furnaces Vent Pipe BAYCNDTRAP3A Inline Condensate Trap Kit used with Special Venting on 3" All Furnaces Vent Pipe (a) Airflow greater than 1600 CFM requires dual returns (b) Designed to fit all S-Series furnaces with or without transition when used in side return.Fits B width cabinet without a transition in upflow/downflow applications. 12-1389-1 E-EN 5 ,��cler�rca� s��d HEATING & AIR CONDITIONING Product Specifications MODEL S9X2B040U3PSBA(a) S9X2B060U4PSBA(a) S9X2B080U4PSBA(a) S9X2C080U5PSBA(a) TYPE Upflow/Horizontal Upflow/Horizontal Upflow/Horizontal Upflow/Horizontal RATINGS(b) 1st Stage Input BTUH(ICS) 26,000 39,000 52,000 52,000 1st Stage Capacity BTUH 25,220 37,830 50,440 50,440 2nd Stage Input BTUH 40,000 60,000 80,000 80,000 2nd Stage Capacity BTUH(ICS)(_)(d) 38,800 58,200 77,600 77,600 1st Stage Temp.Rise(Min.-Max.) 25-55 25-55 30-60 30-60 2nd Stage Temp.Rise(Min.-Max.) 30-60 30-60 45-75 40-70 AFUE(%) 96.0 96.0 96.0 95.0 BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Diameter—Width(In.) 11 X 8 11 X 8 11 X 8 11 X 10 No.Used 1 1 1 1 Speeds(No.)(e) 9 9 9 9 CFM vs.in.w.g. See Fan Pe ormance See Fan Performance See Fan Performance Table See Fan Performance Table Table Table Motor HP 1/2 3/4 3/4 1 RPM 1075 1075 1075 1075 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 120/1/60 FLA 6.4 7.6 7.6 10.6 COMBUSTION FAN—Type Centrifugal Centrifugal Centrifugal Centrifugal Drive—No.Speeds Direct-2 Direct-2 Direct-2 Direct-2 Motor HP—RPM 3300/2600 3300/2600 3300/2600 3300/2600 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 120/1/60 FLA 0.61 0.79 0.96 0.88 FILTER—Furnished? No No No No Type recommended High Velocity High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 1—16x25—1 in. 1—16x25—1 in. 1—16x25—1 in. 1—20x25—1 in. VENT PIPE DIAMETER—Min(in.)M (e) 2 Round 2 Round 2 Round 2 Round HEATEXCHANGER Type—Fired 409 Stainless Steel 409 Stainless Steel 409 Stainless Steel 409 Stainless Steel —Unfired 29-4C Stainless Steel 29-4C Stainless Steel 29-4C Stainless Steel 29-4C Stainless Steel Gauge(Fired) 20 20 20 20 ORIFICES—Main Nat.Gas Qty.—Drill Size 2-45 3-45 4-45 4-45 LP Gas Qty.—Drill Size 2-56 3-56 4-56 4-56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE Type 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter BURNERS—Type Multiport Inshot Multiport Inshot Multiport Inshot Multiport Inshot 6 12-1389-1 E-EN Awlkemi S-laffdad, HEATING & AIR CONDITIONING Product Specifications MODEL S9X2B040U3PSBA(a) S9X2B060U4PSBA(a) S9X2B080U4PSBA(a) S9X2C080U5PSBA(a) Number 2 3 4 4 POWER CONN.—V/Ph/HZ(h) 120/1/60 120/1/60 120/1/60 120/1/60 Ampacity(In Amps) 8.8 10.3 10.3 14.1 Max.Overcurrent Protection(Amps) 15 15 15 15 PIPE CONN.SIZE(in.) 1/2 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD HxWxD Uncrated(In.) 34 x 17-1/2 x 28-3/4 34 x 17-1/2 x 28-3/4 34 x 17-1/2 x 28-3/4 34 x 21 x 28-3/4 Crated(In.) 35-1/2 x 19-1/2 x 30-7/8 35-1/2 x 19-1/2 x 30-7/8 35-1/2 x 19-1/2 x 30-7/8 35-1/2 x 23 x 30-7/8 WEIGHT Shipping(Lbs.)/Net(Lbs.) 122/114 130/122 135/127 149/139 (a) Meets Energy Star (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applications,above input ratings(BTUH)are up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. (c) Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3—latest edition. (d) Based on U.S.government standard tests. (e) 9 Speed constant torque ECM blower motor M Refer to the Vent Length Table in the Installer's Guide. (9) All S9X2 furnace models have a vent outlet diameter that equals 2 in. (h) The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. MODEL S9X2C10005PSBA(a) S9X2D120U5PSBA(a) S9X2B040D3PSBA(a) S9X2B060D3PSBA(a) TYPE Upflow/Horizontal Upflow/Horizontal Downflow Downflow RATINGS(b) 1st Stage Input BTUH(ICS) 65,000 78,000 26,000 39,000 1st Stage Capacity BTUH 63,050 75,660 25,220 37,830 2nd Stage Input BTUH 100,000 120,000 40,000 60,000 2nd Stage Capacity BTUH(ICS)(c)(d) 97,000 116,400 38,800 58,200 1st Stage Temp.Rise(Min.-Max.) 25-55 30-60 25-55 25-55 2nd Stage Temp.Rise(Min.-Max.) 40-70 40-70 30-60 35-65 AFUE(%) 96.0 96.0 96.0 95.0 BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Diameter—Width(In.) 11 X 10 11 X 10 11 X 8 11 X 8 No.Used 1 1 1 1 Speeds(No.)(e) 9 9 9 9 CFM vs.in.w.g. See Fan Performance See Fan Performance See Fan Performance See Fan Performance Table Table Table Table Motor HP 1 1 1/2 1/2 RPM 1075 1075 1075 1075 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 120/1/60 FLA 10 10.6 6.4 6.4 COMBUSTION FAN—Type Centrifugal Centrifugal Centrifugal Centrifugal Drive—No.Speeds Direct-2 Direct-2 Direct-2 Direct-2 Motor HP—RPM 3300/2600 3300/2600 3300/2600 3300/2600 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 120/1/60 FLA 0.66 0.66 0.66 0.66 FILTER—Furnished? No No No No Type recommended High Velocity High Velocity High Velocity High Velocity 12-1389-1 E-E N 7 71*i eao S-lavdard® HEATING & AIR CONDITIONING Product Specifications MODEL S9X2C10005PSBA(a) S9X2D120U5PSBA(a) S9X2BO4OD3PSBA(a) S9X2BO6OD3PSBA(a) Hi Vel.(No.-Size-Thk.) 1—20x25—1 in. 1—24x25—1 in. 2—14x20—1 in. 2—14x20—1 in. VENT PIPE DIAMETER—Min(in.)M(g) 2 Round 3 Round 2 Round 2 Round HEATEXCHANGER Type—Fired 409 Stainless Steel 409 Stainless Steel 409 Stainless Steel 409 Stainless Steel —Unfired 29-4C Stainless Steel 29-4C Stainless Steel 29-4C Stainless Steel 29-4C Stainless Steel Gauge(Fired) 20 20 20 20 ORIFICES—Main Nat.Gas Qty.—Drill Size 5-45 6-45 2-45 3-45 LP Gas Qty.—Drill Size 5-56 6-56 2-56 3-56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE Type 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter BURNERS—Type Multiport Inshot Multiport Inshot Multiport Inshot Multiport Inshot Number 5 6 2 3 POWER CONN.—V/Ph/Hz(h) 120/1/60 120/1/60 120/1/60 120/1/60 Ampacity(In Amps) 13.3 14.1 8.8 8.8 Max.Overcurrent Protection(Amps) 15 15 15 15 PIPE CONN.SIZE(in.) 1/2 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD HxWxD Uncrated(In.) 34 x 21 x 28-3/4 34 x 24-1/2 x 28-3/4 34 x 17-1/2 x 28-3/4 34 x 17-1/2 x 28-3/4 Crated(In.) 35-1/2 x 23 x 30-7/8 35-1/2 x 26-1/2 x 30-7/8 35-1/2 x 19-1/2 x 30-7/8 35-1/2 x 19-1/2 x 30-7/8 WEIGHT Shipping(Lbs.)/Net(Lbs.) 155/145 167/156 122/114 127/119 (a) Meets Energy Star (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applications,above input ratings(BTUH)are up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. (0 Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3. (d) Based on U.S.government standard tests. (e) 9 Speed constant torque ECM blower motor M Refer to the Vent Length Table in the Installer's Guide. (g) All S9X2 furnace models have a vent outlet diameter that equals 2 in. (h) The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. MODEL S9X2B080D4PSBA(a) S9X2C100D5PSBA(a) S9X2D120D5PSBA(a) TYPE Downflow Downflow Downflow RATINGS(b) 1st Stage Input BTUH(ICS) 52,000 65,000 78,000 1st Stage Capacity BTUH 50,440 63,050 75,660 2nd Stage Input BTUH 80,000 100,000 120,000 2nd Stage Capacity BTUH(ICS)(c)(d) 77,600 97,000 116,400 1st Stage Temp.Rise(Min.-Max.) 30-60 25-55 30-60 2nd Stage Temp.Rise(Min.-Max.) 45-75 40-70 45-75 AFUE(%) 96.0 95.0 96.0 BLOWER DRIVE DIRECT DIRECT DIRECT Diameter—Width(In.) 11 X 8 11 X 10 11 X 10 No.Used 1 1 1 Speeds(No.)(e) 9 9 9 8 12-1389-1 E-E N Awikeai S-laffdard. HEATING & AIR CONDITIONING Product Specifications MODEL S9X2B080D4PSBA(a) S9X2C100DSPSBA(a) S9X2D120DSPSBA(a) CFM vs.in.w.g. See Fan Terlformance See Fan Performance Table See Fan Performance Table Motor HP 3/4 1 1 RPM 1075 1075 1075 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 FLA 9.3 10.6 10.6 COMBUSTION FAN—Type Centrifugal Centrifugal Centrifugal Drive—No.Speeds Direct-2 Direct-2 Direct-2 Motor HP—RPM 3300/2600 3300/2600 3300/2600 Volts/Ph/Hz 120/1/60 120/1/60 120/1/60 FLA 0.66 0.66 0.66 FILTER—Furnished? No No No Type recommended High Velocity High Velocity High Velocity Hi Vel.(No.-Size-Thk.) 2—14x20—1 in. 2—16x20—1 in. 2—16x20—1 in. VENT PIPE DIAMETER—Min(in.)(f)(g) 2 Round 2 Round 3 Round HEATEXCHANGER Type—Fired 409 Stainless Steel 409 Stainless Steel 409 Stainless Steel —Unfired 29-4C Stainless Steel 29-4C Stainless Steel 29-4C Stainless Steel Gauge(Fired) 20 20 20 ORIFICES—Main Nat.Gas Qty.—Drill Size 4-45 5-45 6-45 LP Gas Qty.—Drill Size 4-56 5-56 6-56 GAS VALVE Redundant-Two Stage Redundant-Two Stage Redundant-Two Stage PILOT SAFETY DEVICE Type 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter BURNERS—Type Multiport Inshot Multiport Inshot Multiport Inshot Number 4 5 6 POWER CONN.—V/Ph/Hz(h) 120/1/60 120/1/60 120/1/60 Ampacity(In Amps) 12.4 14.1 14.1 Max.Overcurrent Protection(Amps) 15 15 15 PIPE CONN.SIZE(in.) 1/2 1/2 1/2 DIMENSIONS HxWxD HxWxD HxWxD Uncrated(In.) 34 x 17-1/2 x 28-3/4 34 x 21 x 28-3/4 34 x 24-1/2 x 28-3/4 Crated(In.) 35-1/2 x 19-1/2 x 30-7/8 35-1/2 x 23 x 30-7/8 35-1/2 x 26-1/2 x 30-7/8 WEIGHT Shipping(Lbs.)/Net(Lbs.) 135/127 155/145 167/156 (a) Meets Energy Star (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applications,above input ratings(BTUH)are up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 feet above sea level. (c) Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3. (d) Based on U.S.government standard tests. (e) 9 Speed constant torque ECM blower motor (f) Refer to the Vent Length Table in the Installer's Guide. (g) All S9X2 furnace models have a vent outlet diameter that equals 2 in. (h) The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. 12-1389-1 E-E N 9 ,��ce�rca� �S�iaara! HEATING & AIR CONDITIONING Airflow tables Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SUM 510 314 118 - - Watts 34 43 52 - - 2 SUM 532 341 150 - - Watts 36 45 54 - - 3 SUM 877 748 620 491 362 Watts 91 104 118 131 144 4 SUM 933 813 693 573 452 Watts 106 120 133 147 161 S9X1BO4OU3PSBA 5 SUM 1056 950 843 737 631 S96113O4OU3PSAA 140 156 172 188 204 S9X2BO4OU3PSBA Watts 6 SUM 1111 1009 908 806 705 Watts 157 174 190 207 223 7 SUM 1174 1078 983 887 791 Watts 182 199 216 233 251 8 SUM 1376 1297 1218 1140 1061 Watts 285 305 325 344 364 9 SUM 1512 1445 1378 1312 1245 Watts 382 403 424 445 466 Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SUM 840 702 565 427 290 Watts 91 101 111 121 130 2 SUM 1001 893 786 678 571 Watts 137 149 162 174 186 3 SUM 1140 1051 963 875 786 Watts 193 207 221 235 249 4 SUM 1208 1128 1048 969 889 Watts 223 238 253 268 283 S9X1BO60U4PSBA 5 SUM 1299 1224 1148 1073 998 S913113O6OU4PSAA 270 284 298 312 327 S9X2BO6OU4PSBA Watts 6 SUM 1413 1348 1283 1217 1152 Watts 343 359 375 391 406 7 SUM 1444 1380 1315 1251 1186 Watts 354 370 386 403 419 8 SUM 1727 1674 1622 1570 1518 Watts 612 631 650 668 687 9 SUM 1790 1741 1691 1642 1593 Watts 694 712 729 747 765 10 12-1389-1 E-EN Amm?Ao Si�uid f rd® HEATING & AIR CONDITIONING Airflow tables Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SUM 911 766 622 477 332 Watts 94 104 115 125 136 2 SUM 1075 963 851 740 628 Watts 139 153 168 182 197 3 SUM 1215 1121 1028 934 840 Watts 185 202 219 236 253 4 SUM 1250 1164 1077 990 903 Watts 203 221 239 257 274 S9X1B080U4PSBA 5 SUM 1349 1272 1194 1116 1039 S9131130801.14PSAA 251 271 291 310 330 S9X2B080U4PSBA Watts 6 SUM 1453 1387 1321 1254 1188 Watts 313 335 356 378 400 7 SUM 1505 1438 1372 1305 1239 Watts 340 362 384 406 427 8 SUM 1657 1597 1538 1479 1419 Watts 453 477 500 524 547 9 SUM 1878 1815 1752 1690 1627 Watts 669 686 702 718 735 Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SCFM 643 384 125 Watts 45 53 62 - - 2 SUM 1125 982 838 694 551 Watts 126 142 158 174 190 3 SUM 1192 1038 884 730 576 Watts 140 157 174 191 208 4 SUM 1509 1377 1246 1115 983 Watts 245 268 291 314 337 S9X1C080U5PSBA 5 SUM 1548 1428 1308 1187 1067 S9B1C080U5PSAA 257 281 304 328 352 S9X2CO8OU5PSBA Watts 6 SUM 1602 1467 1331 1196 1061 Watts 320 345 371 396 421 7 SUM 1640 1512 1383 1255 1127 Watts 352 379 406 433 459 8 SUM 1831 1778 1726 1673 1621 Watts 521 550 579 608 637 9 SUM 2351 2278 2204 2131 2058 Watts 886 918 950 982 1014 12-1389-1 E-EN 11 Amwe "S7iwdvid, HEATING & AIR CONDITIONING Airflow tables Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SUM 1013 847 680 514 348 Watts 104 116 129 142 155 2 SUM 1261 1126 990 854 718 Watts 168 185 202 219 236 3 SUM 1519 1407 1296 1184 1072 Watts 267 290 313 336 358 4 SUM 1554 1446 1337 1229 1120 Watts 283 307 330 353 377 S9X1C100USPSBA 5 SUM 1749 1651 1554 1457 1359 S9B1C100USPSAA 385 411 436 462 488 S9X2C10005PSBA Watts 6 SUM 1868 1778 1688 1599 1509 Watts 464 491 519 546 574 7 SUM 2018 1936 1853 1770 1688 Watts 573 602 631 660 689 8 SUM 2191 2112 2033 1954 1875 Watts 718 750 782 815 847 9 SUM 2395 2303 2212 2120 2028 Watts 966 981 996 1012 1027 Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SCFM 707 443 179 - - Watts 46 55 64 - - 2 SUM 1344 1218 1092 966 840 Watts 163 183 202 222 241 3 SUM 1532 1419 1307 1195 1083 Watts 225 247 268 290 312 4 SUM 1584 1477 1370 1263 1156 Watts 247 270 292 315 338 S9X1D120U5PSBA 5 SUM 1915 1818 1722 1625 1529 S9131131201.15PSAA 401 428 454 480 506 S9X2D120U5PSBA Watts 6 SUM 2104 2016 1927 1839 1750 Watts 525 553 582 610 639 7 SUM 2132 2045 1958 1870 1783 Watts 546 575 604 633 662 8 SUM 2410 2328 2247 2165 2084 Watts 833 868 903 937 972 9 SUM 2472 2401 2329 2257 2186 Watts 909 944 979 1013 1048 12 12-1389-1 E-EN Amm?Ao Si�uid f rd® HEATING & AIR CONDITIONING Airflow tables Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SUM 378 153 - - - Watts 28 32 - 2 SUM 514 330 145 - - Watts 35 45 55 64 74 3 SUM 765 618 471 324 178 Watts 69 81 93 105 116 4 SUM 827 691 554 418 281 Watts 81 94 106 119 132 S9X1B040D3PSBA 5 SUM 988 879 770 661 553 S913113040133PSAA 124 140 156 171 187 S9X2B040D3PSBA Watts 6 SUM 1085 986 887 787 688 Watts 156 173 190 207 224 7 SUM 1125 1030 934 839 743 Watts 170 188 205 222 239 8 SUM 1129 1035 941 847 753 Watts 170 187 204 221 239 9 SUM 1492 1419 1346 1273 1200 Watts 369 390 411 431 452 Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SCFM 624 451 277 104 - Watts 47 57 68 79 - 2 SUM 866 734 602 470 338 Watts 89 102 116 129 142 3 SUM 949 833 718 602 486 Watts 113 128 142 156 171 4 SUM 1122 1025 928 831 733 Watts 165 182 200 217 235 S9X113060133PSBA 5 SUM 1178 1087 996 905 814 S913113060133PSAA 191 209 227 246 264 S9X2B060D3PSBA Watts 6 SUM 1260 1180 1100 1021 941 Watts 233 252 271 290 309 7 SUM 1370 1299 1228 1158 1087 Watts 296 316 336 355 375 8 SUM 1480 1416 1352 1287 1223 Watts 365 387 408 429 450 9 SUM 1504 1440 1376 1312 1249 Watts 384 406 427 449 470 12-1389-1 E-EN 13 Amwe "S7iwdvid, HEATING & AIR CONDITIONING Airflow tables Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SUM 499 306 113 - - Watts 36 43 49 - - 2 SUM 1017 922 828 734 640 Watts 143 158 173 188 203 3 SUM 1119 1029 940 850 761 Watts 176 192 207 223 239 4 SUM 1205 1125 1044 964 883 Watts 215 233 250 268 285 S9X1B080D4PSBA 5 SUM 1237 1160 1083 1006 928 S913113080134PSAA 231 250 268 286 305 S9X2B080D4PSBA Watts 6 SUM 1378 1309 1240 1172 1103 Watts 315 334 354 373 393 7 SUM 1453 1389 1324 1260 1195 Watts 360 380 399 419 439 8 SUM 1618 1562 1505 1449 1392 Watts 496 518 540 561 583 9 SUM 1794 1742 1691 1639 1587 Watts 682 704 726 748 770 Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SCFM 1002 823 644 465 285 Watts 103 117 130 144 157 2 SUM 1385 1276 1167 1057 948 Watts 223 243 264 284 304 3 SUM 1527 1430 1333 1236 1139 Watts 286 310 333 357 380 4 SUM 1610 1516 1421 1326 1231 Watts 328 352 377 401 425 S9X1C100D5PSBA 5 SUM 1761 1677 1593 1509 1425 S9B1C100DSPSAA 433 459 486 512 538 S9X2C100D5PSBA Watts 6 SUM 1861 1783 1706 1628 1551 Watts 492 520 549 577 605 7 SUM 1984 1902 1820 1738 1656 Watts 548 577 606 635 663 8 SUM 2173 2097 2020 1944 1867 Watts 728 760 792 824 856 9 SUM 2342 2269 2196 2123 2050 Watts 945 973 1002 1031 1060 14 12-1389-1 E-EN Amm?Ao Si�uid f rd® HEATING & AIR CONDITIONING Airflow tables Furnace Airflow(CFM)Vs.External Static Pressure(in.W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SUM 680 419 159 - - Watts 47 56 66 - - 2 SUM 1025 1063 1101 1139 1177 Watts 237 259 282 304 327 3 SUM 1566 1461 1357 1253 1149 Watts 268 292 316 340 363 4 SUM 1803 1711 1619 1527 1435 Watts 393 420 446 472 498 S9X1D120DSPSBA 5 SUM 1891 1801 1711 1621 1532 S913113120135PSAA 445 472 500 527 555 S9X2S120D5PSBA Watts 6 SUM 2132 2025 1919 1812 1705 Watts 568 601 633 666 698 7 SUM 2154 2068 1982 1896 1810 Watts 644 675 705 736 766 8 SUM 2344 2267 2190 2113 2035 Watts 837 870 902 934 967 9 SUM 2414 2333 2251 2170 2088 Watts 896 928 961 993 1026 12-1389-1 E-EN 15 �c icati, �S'7 iw HEATING & AIR CONDITIONING CFM Versus Temperature Rise S9X1 and S9B1 furnaces have one stage heating S9X2 Furnaces have two stage heating.First Stage is Low heating and Second Stage is High heating. Table 2. Heating Table — Upf low CFM VS.TEMPERATURE RISE MODEL 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 S9X1B040U3PSBA 55 48 44 39 36 33 30 S9131130401-13PSAA S9X1B060U4PSBA 63 58 52 49 46 43 41 40 S9B1B060U4PSAA S9X1B080U4PSBA 64 61 57 54 51 48 44 39 35 S9B1B080U4PSAA S9X1CO80U5PSBA 65 59 56 54 49 46 44 42 40 38 36 S9131C080U5PSAA S9X1C10005PSBA 65 61 57 55 53 49 46 44 43 S9B1C10005PSAA S9X1D120U5PSBA 67 65 60 55 54 51 48 44 41 S9B1D120U5PSAA Table 3. 2nd Stage Heating Table — Upf low CFM VS.2ND STAGE TEMPERATURE RISE CFM(CUBIC FEET PER MINUTE) MODEL 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 S9X2B040U3PSBA 60 51 45 40 36 33 S9X2B060U4PSBA 60 54 49 45 41 38 36 34 32 S9X2B080U4PSBA 72 65 60 55 51 48 S9X2C080U5PSBA 65 60 55 51 48 45 42 S9X2C10005PSBA 69 64 60 56 53 50 47 45 43 41 S9X2D120U5PSBA 67 63 60 57 54 51 49 Table 4. 1st Stage Heating Table — Upflow CFM VS. 1ST STAGE TEMPERATURE RISE MODEL 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 S9X2B040U3PSBA 51 45 40 36 33 30 28 26 S9X2B060U4PSBA 54 49 45 41 38 36 34 32 30 28 27 26 S9X2B080U4PSBA 60 55 51 48 45 42 40 38 36 34 S9X2C080U5PSBA 60 55 51 48 45 42 40 38 36 34 S9X2C10005PSBA 53 50 47 45 43 S9X2D120U5PSBA 60 57 54 51 16 12-1389-1 E-E N Amm?Ao S*odfrd® HEATING & AIR CONDITIONING CFM Versus Temperature Rise Table 5. Heating Table — Downflow CFM VS.TEMPERATURE RISE CFM(CUBIC FEET PER MINUTE) MODEL 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 S9X1B040D3PSBA 53 46 45 37 34 31 S9B1B040D3PSAA S9X1B060D3PSBA 63 58 52 48 44 41 37 S9B1B060D3PSAA S9X1B080D4PSBA 62 57 53 49 48 46 S9B1B080D4PSAA S9X1C100D5PSBA 65 62 58 55 53 50 48 44 S9B1C100D5PSAA S9X1D120D5PSBA 66 64 58 56 53 52 49 44 S9B1D120D5PSAA Table 6. 2nd Stage Heating Table — Downflow CFM VS.2ND STAGE TEMPERATURE RISE CFM(CUBIC FEET PER MINUTE) MODEL 600 700 800 900 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- 21- 22- 00 00 00 00 00 00 00 00 00 00 00 00 00 S9X2B040D3PSBA 60 51 45 40 36 33 S9X2B060D3PSBA 60 54 49 45 41 38 36 S9X2B080D4PSBA 72 65 60 55 51 48 S9X2C100D5PSBA 69 64 60 56 53 50 47 45 43 41 S9X2D120D5PSBA 72 67 63 60 57 54 51 49 Table 7. 1st Stage Heating Table — Downflow CFM VS.1ST STAGE TEMPERATURE RISE MODEL 700 800 900 100- 1100 1200 130- 1400 1500 160- 1700 180- 1900 2000 2100 0 0 0 0 S9X2B040D3PSBA 51 45 40 36 33 30 28 26 S9X2B060D3PSBA 54 49 45 41 38 36 34 32 30 28 27 26 S9X2B080D4PSBA 60 55 51 48 45 42 40 38 36 34 S9X2C100D5PSBA 53 50 47 45 43 S9X2D120D5PSBA 60 57 54 51 12-1389-1 E-EN 17 ,��cier�rca� �S�iaara! HEATING & AIR CONDITIONING Maximum Vent Length Table S9X2 Maximum Vent Length Table Maximum Total Equivalent Length In Feet for Vent and Inlet Air(See Notes) Model 2 Inch or 2.5 Inch Pipe 3 Inch or 4 Inch Pipe Altitude 0-2,000 Feet S9X2B040U3PS,S9X2B040D3PS, 200 200 S9X2B060D3PS,S9X2B060U4PS S9X2B080U4PS,S9X2B080D4PS, 100 200 S9X2C080U5PS S9X2C10005PS,S9X2C100D5PS 50 200 S9X2D120U5PS,S9X2D120D5PS Note 200 Altitude 2,001-5,400 Feet S9X2B040U3PS,S9X2B040D3PS, 200 200 S9X2B060D3PS,S9X2B060U4PS S9X2B080U4PS,S9X2B080D4PS, 80 120 S9X2C080U5PS S9X2C10005PS,S9X2C100D5PS 50 150 S9X2D120U5PS,S9X2D120D5PS Note 200 Altitude 5,401-7,800 Feet S9X2B040U3PS,S9X2B040D3PS, 100 150 S9X2B060D3PS,S9X2B060U4PS S9X2B080U4PS,S9X2B080D4PS, 50 70 S9X2C080U5PS S9X2C10005PS,S9X2C100D5PS Note 100 S9X2D120U5PS,S9X2D120D5PS Note 100 Altitude 7,801-10,100 Feet S9X2B040U3PS,S9X2B040D3PS, 50 90 S9X2B060D3PS,S9X2B060U4PS S9X2B080U4PS,S9X2B080D4PS, Note 50 S9X2C080U5PS S9X2C10005PS,S9X2C100D5PS Note 50 S9X2D120U5PS,S9X2D120D5PS Note 50 Notes: 1. Not allowed 2. For PolyPro@ by Duravent,Z-DENS by Novaflex Group,InnoFlue@by Centrotherm,and Polyflue'"manufactured modular venting systems that are in the approved vent pipe material table,fitting equivalent vent lengths may be different from what is shown in Note 6.Refer to the venting system manufacturer's installation instruction for appropriate venting diameters and equivalent lengths. 3. Minimum vent length for all models: 15'equivalent. 4. DO NOT MIX PIPE DIAMETERS IN THE SAME LENGTH OF PIPE OUTSIDE THE FURNACE CABINET(Except adapters at the top of the furnace). If different inlet and vent pipe sizes are used,the vent pipe must adhere to the maximum length limit shown in the table above(See note 7 below for exception).The inlet pipe can be of a larger diameter,but never smaller than the vent pipe. 5. MAXIMUM PIPE LENGTHS MUST NOT BE EXCEEDED!THE LENGTH SHOWN IS NOTA COMBINED TOTAL,IT IS THE MAXIMUM LENGTH OF EACH(Vent or Inlet air pipes). 6. One SHORTradius 900 elbow is equivalent to 10'of 4"pipe,10'of 3"pipe,or 8'of 2"pipe.One LONG radius elbow is equivalent to 6'of 4" pipe,7'of 3"pipe,or 5'of 2"pipe.Two 450 elbows equal one 900 LONG elbow.One MITERED elbow is equivalent to 12'of 3"pipe or 12'of 2"pipe. 7. The termination tee or bend must be included in the total number of elbows.If the BAYAIR30AVENTA or BAYAIR30CNVENT termination kit is used,the equivalent length of pipe is 5 feet.For BAYVENT200B and BAYVENTCN200B the equivalent length is 0 feet. 8. For Canadian applications,venting systems must meet ULC-5636 requirements. 9. The INLETAIR of one pipe systems require the installation of a minimum of one 900 elbow(to prevent dust and debris from falling straight into the furnace). 18 12-1389-1 E-EN HEATING & AIR CONDITIONING S9X2 Wiring Diagram S9X2 Wiring Diagram and Schematic TO BURNER BOX HARN YLA 1 1 YU48 FLAME_ROLLOUTI YL146 2 2 YU49 YU50 YU48 INDUCER LIMIT CONDENSATE I__ I _RAF-1 FLAM-E_R'OLLLOOUT2 PR154 YU52 I YU45 YU50 YU51 L-- L-- SEE NOTE THE RMAL_L MMIT YU47 RAF-2 9 YL149 YU51 PS2 I PS1 I YU45 I-- GAS VALVE I - , }Y I__ I I I J I I BU42 1 5 L TO 1 2 BKJ39 2 4 POWER BLOWER 1 2 3o HARNESS 1 2 WH/40 4 G MOTOR 2 'SEE NOTE 10 iid a RD/WHl35 YLNVH/36 BLNVH/37 BKANH/38 o ORANH18 i i m m 120v 60 Hz.1 PH POWER SUPPLY PER LOCAL CODE IF C IS POLARITY SENSITIVE 1 2 3 4 5 6 7 8 9 10 11 12 JUNCTION BOX r N 7 6 910 1112 IH I BU2 WH115 _ GND 24v I 2M »smm 33i� RDI6 �BKI14 SEE NOTE 8 o, LINE CHOKE i BK'28 BW30 2 2 BKJ13 BK129 W27 PANEL LOOP B mL21 3 4 3 2 1 1 L EAC HUM LINE NEUTRAL GRiYL I I I I I I I I I I 11<118 1 VENT 241120 VAC 3 2 1 4 3 2 1 RD119 2 MOTOR MAY BE USED z z � `r WHI20 3 (INDUCER) m m m SEE NOTE 7 z IGN IGN-N 5 WH121 WH121 1 12 FP IND-N 4 WH/20 BIJ22 2 BR/53 11 HLI IND-LO 3 RD/19 BRI10 10 MVH IND-HI 2 BK118 RD/9 9 MVL as IGN-H 1 BK/22 LINE FACTORY 8 GND 24V)WIRING g�j 7 PS2 ®® TAPi 1 RDNVHl23 _LINE RDI6 6 TH TAP2 2 YUWH/24 - FIELD BU5 5 MVC TAP3 3 BLMH125 - 24V WIRING PR/4- HLO TAP4 4 BKNVH126 OR111 3 PSI TAP5 5 ORNJHI56 BK BLACK OR ORANGE BR BROWN WH WHITE PR PURPLE RD RED BU2 2 TR GND fi BU57 YL IYELLOWI GR I GREEN I BL IBLUE FIRM ILI H LINE N NEUTRAL INTEGRATED FURNACE CONTROL mGND GROUND ELECTRICAL RATING TIMINGS 1 FLAME 5AMP HLO HIGH LIMIT OUTPUT OR EQUIVALENT PREPURGE:0 SEC. WH/12 HLI HIGH LIMIT INPUT INPUT 24 VAC,60 HZ. INTERPURGE:60 SEC. PSi 1ST STAGE XFMR SEC.CURRENT: POST PURGE:5SEC. m- I FC r r ) I 1 PRESSURE INPUT 450 MA.+MV LOAD IGN WARMUP:20 SEC. PS2 2ND STAGE MV OUTPUT:1.5A @ 24 VAC IAP:2;TFI:5 SEC. W2 Wi R B Y2 YI PRESSURE INPUT IND OUTPUT:2.2 FLA,3.5 LRA RETRIES:2 RECYCLES:10 mERMTAT IND INDUCER @120 VAC MAX. HEAT ON DELAY:30 SEC. "INTERNAL THERMAL PROTECTION SEE NOTES 2,3,4,5 IFC INTEGRATED IGN OUTPUT:2.0 A@ 120 VAC COOL ON DELAY:0 SEC. FURNACE CONTROL CIRC.BLOWER OUTPUT: AUTO RESTART:60 MIN. CONDENSATE RAF REVERSEAIRFLOW 14.5 FLA,25 LRA@ 120 VAC AUTO RESTART PURGE:60 SWITCH o�vo FUSE FRS FLAME ROLLOUT TH 24VAC(HOT) HUMIDIFIER&AIR CLEANER SEC. SWITCH TR 24VAC(COMMON) (DRY CONTACTS) MVC VALVE COMMON MAX.LOAD:I.O A@ 120 VAC RAF REVERSE MVL VALVE LOW STAGE 24 VAC OR 120 VAC MAY BE AIR FLOW 6b LC LINE CHOKE �� FP FLAME PROBE MVL VALVE HIGH STAGE USED FUSE:5A _ q IGN HOT SURFACE TNS TRANSFORMER DEFAULT BLOWER MOTOR TAP SELECTIONS O PS PRESSURE GROUND �1=i IGNITER ILI INDUCER LIMIT INPUT COF CONSTANT FAN:TAP SWITCH T IGN IGNITER CL1(�IRST STAGE C(iOLING:TAP FP FLAME PROBE CL2(SECOND STAGE COOLING):TAP 4 HI 2ND STAGE HT1(FIRST STAGE HEAT):TAP 3 LO 1ST STAGE HT2(SECOND STAGE HEAT):TAP 5 12-1389-1 E-EN 19 Amwe "S7iwdad HEATING & AIR CONDITIONING S9X2 Wiring Diagram NOTES: 1. IF ANY OF THE ORIGINAL WIRING AS SUPPLIED WITH THIS FURNACE MUST BE REPLACED,IT MUST BE WITH WIRE HAVING A TEMPERATURE RATING OF AT LEAST 105°C. WIRES 12,48,49,50,AND 51 REQUIRE ATEMPERATURE RATING OF AT LEAST 250°C. 2. FOR PROPER AIRFLOW IN COOLING/HEAT PUMP MODE,"Y1"MUST BE CONNECTED TO THE THERMOSTAT FOR SINGLE STAGE UNITS. FOR TWO STAGE UNITS,"Y1"AND"Y2"MUST BE CONNECTED TO THE THERMOSTAT. 3. FOR SINGLE STAGE THERMOSTATS,JUMPER"W1"AND"W2"TERMINALS.SECOND STAGE HEATING WILL BE ENERGIZED ONCE THE INTER-STAGE DELAY HAS EXPIRED. "HT2"WILL BE SHOWN ON DISPLAY AT ALL TIMES. 4. FOR HEAT PUMP SYSTEMS,"Y1"AND"0"TERMINALS MUST BE CONNECTED TO THE ROOM THERMOSTAT. FOR TWO STAGE UNITS, "Y1","Y2",AND"0"TERMINALS MUST ALL BE CONNECTED TO THE ROOM THERMOSTAT. 5. FOR TWO STAGE SYSTEMS,USE"Y1"FOR LOW SPEED AND"Y2"FOR HIGH SPEED CONNECTION TO THE LOW-VOLTAGE TERMINAL BLOCK. SINGLE STAGE SYSTEMS USE"Y1"FOR THE CONNECTION TO THE LOW-VOLTAGE TERMINAL BLOCK. 6. THE INDOOR BLOWER MOTOR AIRFLOW TABLES ARE LOCATED IN THE SERVICE FACTS. TO CHANGE AIRFLOW USE THE MENU/OPTIONS BUTTONS. 7. FLAME SENSE TEST PADS:1 VDC=1 MICROAMP.FLAME CURRENT CAN VARY DEPENDING ON THE VOM THAT IS S9X2 USED AND THE VOLTAGE SUPPLIED TO THE FURNACE. THE ACCEPTABLE RANGE IS 0.75-3 MICROAMPS. 8. LINE CHOKE AND WIRE BK/28 ONLY USED ON MODELS WITH 3/4 AND 1 HP MOTORS. 9. DOWNFLOW MODELS USE ONLY ONE REVERSE AIRFLOW SWITCH. 10.CONNECTION MAY OR MAY NOT BE PRESENT. IF CONNECTION IS NOT PRESENT,WIRES 33 AND 34 WILL NOT BE USED. 2 Stage Inducer with CTM Blower Motor •• 15d I Inter-Stage Delay sec E34 Open Pressure Switch,2nd Stage I dL Idle COF Blower Tap Number for Continuous Fan E04 Open Thermal Limit,Rollout Switch,or Reverse Airflow Switch HE I 1st Stage Heating COP C I Blower Tap for 1 st Stage E05 Flame detected,should not be present HL2 2nd Stage Heating Compressor Mode EE I Voltage reversed polarity EP Blower Tap Number C2.Blower Tap for 2nd Stage E62 BadGroundin [OF Continuous Fan Compressor Mode Efi3 g"ter re ay fails EL 11st Stage Cooling HEP H t Blower Tap for 1st Stage Heating (2)Igniter open CL2 2nd Stage Cooling HE Blower Tap for 2nd Stage Heatinq E1 11st stage gas valve MVL is energized when it should be o HP 11st Sta a HeatPumD Un I Run Test Mode E09 Flame current is low,but still strong enough to allow operation. HP2 2nd Sta a Heat Hump • •• E09 Open Inducer Limit Switch or Condensate Switch dFt Defrost Mode ED I Loss of the IRQ/other internal failures E I 1 (1)1st stage gas valve not energized when it should be •• • E21 Retry exceeded Failed to est flame (2)1 st stage gas valve relay stuck closed Err Active Alarm Menu E22 Recycles exceeded(loss of established (3)2nd stage gas valve relay stuck closed LSF Last 6 Faults(To Clear, flame)or 1 OX PS1 open (4)2nd stage gas valve energized when it Hold Option Button 5 sec E23 1 st Stage Gas Valve not energized when should not be Cr Code Release Number it should be exceeded after 10 times (5)2nd stage gas valve not energized when COd Coolin Off Dela sec E3 I Shorted Pressure Switch 1st Sta e t should be OdiJ Outdoor UnitI E32 I Open Pressure Switch 1st Stage E 12 Open fuse r Mild I Heat Off Delay sec E33 I Shorted Pressure Switch 2nd Stage D346024P01 20 12-1389-1 E-EN �c icati, �S'7 iw HEATING & AIR CONDITIONING Electrical Connections Make wiring connections to the unit as indicated on enclosed wiring diagram.As with all gas appliances using electrical power,this furnace shall be connected into a permanently live electric circuit.It is recommended that furnace be provided with a separate"circuit protection device" electric circuit.The furnace must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code,ANSI/NFPA 70 or CSA C22.1 Electrical Code,if an external electrical source is utilized.The integrated furnace control is polarity sensitive.The hot leg of the 120V power supply must be connected to the black power lead as indicated on the wiring diagram. Refer to the SERVICE FACTS literature and unit wiring diagram attached to furnace. Field Wiring Two Stage FIELD WIRING DIAGRAM FOR Thermostat Furnace TWO STAGE HEATING THERMOSTAT,TWO STAGE COOLING NOTES: _ 1) The factory Y1-0 jumper must remain in place for proper W2 _____ - W2 LED read out in cooling mode. Outdoor Unit 2) Y1 and Y2 wiring from the thermostat must connect to W1 -- ----- -- W1 (No Transformer) the IFC for proper airflow and LED readout. Q 3) Single compressor and two stage airflow is automatically L'�f__ _____ __® LB/C set with the IFC Menu options in ODU section. _ 2-1=2 stage/ 1 compressor E f-- Note: First stage airflow should be set to deliver ----- --© between 70-80% of second stage airflow Y2 B/C -- ----- -- Y2 -- ----- -- Y2--- - �Y1 Y1 -- ----- -- Y1 -- -------- O INTER-COMPONENT WIRING SEE --------- 24 V FIELD WIRING NOTE 1 24 V FACTORY WIRING 12-1389-1 E-E N 21 71*i eao S-lavdard® HEATING & AIR CONDITIONING Electrical Connections Two Stage Thermostat Furnace FIELD WIRING DIAGRAM FOR TWO STAGE HEATING THERMOSTAT,TWO STAGE HEAT PUMP Outdoor Unit NOTES: (No Transformer) 1) Remove the factory Y1-O jumper for HP systems W2 -- ----- -- W2 for proper LED read out. 2) Y1 and Y2 wiring from the thermostat must connect to Y1 and W1 - ----- - W1 - - - - -- X2 Y2 of the IFC for proper airflow and LED readout. 3) Single compressor and two stage airflow is automatically - ----- --jr —J __ _____ __J R set with the IFC Menu options in ODU section. Q 2-1=2 stage/ 1 compressor J� -- - ;LB/C Note: First stage airflow should be set to deliver u between 70-80% of second stage airflow BIC - ---- -- -Y2 Y2 - ---- -- Y2-- - -- ----- -- Y1 SEE NOTE 1 �- -- - - - -' INTER-COMPONENT WIRING 24 V FIELD WIRING 24 V FACTORY WIRING SingleSt age Furnace FIELD WIRING DIAGRAM FOR Thermostat SINGLE STAGE HEATING THERMOSTAT,SINGLE STAGE COOLING NOTES: 1) The factory Y1-O jumper must remain in place for proper SEE W2 -- - LED read out in cooling mode. NOTE 3 2) Y1 wiring from the thermostat must connect to Y1 of the IFC for proper airflow and LED readout. 3) Place field supplied jumper between W1 and W2 on the IFC. Interstage delay is factory set for 10 minutes but is field ® R r Outdoor Unit adjustable with the Menu option in the ISD section. © (No Transformer) Note: HT2 will be shown during the entire heating cycle but the interstage delay setting will control when 2nd stage heating is actually energized. BIC -- ----- -- BIC -- ---- - B/C 4) Single stage airflow is set with the IFC Menu options in ODU section. Select 1-1. Y2 'I LY1 Y1 -- ----- --Er- -------- INTER-COMPONENT WIRING SEE --------- 24V FIELD WIRING NOTE 1 24 V FACTORY WIRING 22 12-1389-1 E-E N Awe eai S-laffdard. HEATING & AIR CONDITIONING Electrical Connections Single Stage Thermostat Furnace FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING THERMOSTAT,SINGLE STAGE HEAT PUMP NOTES: SEE Outdoor Unit 1) Remove the factory Y1-O jumper for HP systems NOTE 3 (No Transformer) for proper LED read out. Q 2) Y1 wiring from the thermostat must connect to Y1 of W1 W1 =_ -- ___I LX2 the IFC for proper airflow and LED readout. -- ----- -- 3) Place field supplied jumper between W1 and W2 on the f - -- - -1,t f- - - R IFC. Interstage delay is factory set for 10 minutes but is field L,� adjustable with the Menu option in the ISD section. Note: HT2 will be shown during the entire heating cycle but the -- ---- --© interstage delay setting will control when 2nd stage heating is actually energized. B/C -- ----- -- B/C -- ----- ---' BIC 4) Single stage airflow is set with the IFC Menu options in ODU section. Select 1-1. Y2 Y1 Y1 -- ----- -- Y1 - ----- ---I SEE NOTE 1 -- ----- --�-- ----- -- o INTER-COMPONENT WIRING 24 V FIELD WIRING 24 V FACTORY WIRING 12-1389-1 E-E N 23 ,��ce�rca� �S�iaara! HEATING & AIR CONDITIONING Outline Drawings �o = �r roQ LLro 0O NLn � m Q co)OQ -�-. I I I I - Sg - 24 12-1389-1 E-EN ,4*weao S*odsrd HEATING & AIR CONDITIONING Outline Drawings U �+ � v LL (a U O N N Q N 2 - - W i i _"- z Q �W j ml Li!--] _ 12-1389-1 E-EN 25 Amwe "S7iwdv-d, HEATING & AIR CONDITIONING Outline Drawings --- a �r . I � I + + —F—T LL V O � N Q N 0 0 ®❑� _ 0 0 ,62 tc w j -- W 26 12-1389-1 E-EN ,4*weao S*odsrd HEATING & AIR CONDITIONING Outline Drawings v v• L T ;�p D7 � d• W - U n LLL J � r 0 V N m Q �OQ 1 T T 1 . - I I I � I I I I - I I -m I - 12-1389-1 E-EN 27 Amwe "S7iwdv-d, HEATING & AIR CONDITIONING Outline Drawings a• Tk � d * _ W V _ m i 4� LL U N N_ O L'I 0 V ❑� � I I _ I I H- I I I - I 28 12-1389-1 E-EN ,4*weao S*odsrd HEATING & AIR CONDITIONING Outline Drawings v e e + V ' i N LL O = V c: N O V) 0 � O O 0 ®OQ 0 0 I � I I I r 12-1389-1 E-EN 29 Notes 30 12-1389-1 E-E N Notes 12-1389-1 E-E N 31 4j:Pingersoll Rand© Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club CarT), Ingersoll RandID, Thermo Kingg and Trane®—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables;and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progress and enduring results. 4$Vingersoll Rand Tr THERMO KING TRANE® ingersollrand.com m C Eta �s ril7i.71Y13 Mi. Intertek Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 12-1389-1 E-EN 01 Aug 2019 Supersedes12-1389-1D-EN (July2018) ©2018 Ingersoll Rand Permit#: 6713 Permit Date: 09/15/25 Permit Type: RESIDENTIAL MECHANICAL Project Name: O'HAGAN MECH PERMIT Applicant Name: CM HEATING Applicant Address: 1500 INDUSTRY ST#200 Applicant, City, State, Zip: EVERETT Contact: SABRINA KENNARD Phone: 4252590550 Email: PERMITS@CMHEATING.COM Scope of Work: GAS FURNACE SWAP Valuation: 8557.00 Square Feet: 1968 Number of Stories: 2 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 09/16/2025 Permit Expires: 03/13/2026 Form Permit Type: RESIDENTIAL MECHANICAL Status: COMPLETE Assigned To: Hannah Hardwick Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 100 SINGLE 00621300006700 17731 33RD AVE NE OHAGEN P J FAMILY RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Plumbing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751W ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION UBI 605890285 ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status R00.FURNACE 360-659-3291 Pat would 09/23/2025 FINAL like a call 09/24/2025 09/24/2025 BUILDING Approved Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Forced Air Heat<100 BTU/h Enter#of units $15.00 Mechanical Base Permit Fee $25.00 Credit Card Service $4.20 Total $144.20 Attached Letters Date Letter Description 09/15/2025 Building Permit 09/15/2025 Web Form-Residential Mechanical Application Payments Date Paid By Description Payment Type Accepted By Amount 09/15/2025 Matt Zivanov 243075073 Hannah Hardwick $4.20 09/15/2025 XBP Conf: $140.00 243075073 Outstanding Balance $0.00 Uploaded Files Date File Name 09/16/2025 28303805-2025 BLD6713 Issued Permit.pdf 09/15/2025 54f9f93a7baa5e6488b510308b8469fb ohagan app.pdf 09/15/2025 faea7e8938dcacae013927bc45baebef 12-1389-le-en 1 .pdf