HomeMy WebLinkAbout8324 175TH ST NE_BLD6705_2026 CITY OF ARLINGTON
18204 59th Avenue NE,Arlington,WA 98223
INSPECTIONS:360-403-3417-Permit Center:360-403-3551
BUILDING PERMIT
8324 175TH ST NE Permit#: 6705
Parcel#:00958500000500 PERMIT EXPIRES 180 DAYS AFTER
DATE OF ISSUANCE.
Scope of Work:Install HISENSE:3-ton heat pump system Valuation:29000.00
OWNER APPLICANT CONTRACTOR
O'NEILL GREGORY J&CAROL L Legacy One Heating Legacy One Heating
8324 175TH ST NE 4403 Russell Road#111 4403 Russell Road#111
ARLINGTON,WA 98223-4051 Muldheo,WA 98275 Mukilteo,WA 98275
4253747052
LIC:604 006 069 EXP:09/30/2026
LIC:LEGACOH84513 EXP:06/23/2026
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
LIC#: EXP: LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2021
STORIES: I CONST.TYPE: VB
DWELLING UNITS: OCC GROUP: R-3;Residential
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any
other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the
Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any
period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice
or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid. The building official is
authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or
any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or
decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or
on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or
federal law,or any order,proclamation,guidance or decision of the Governor.
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK
AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE
STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND
ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN
MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1 10/IRC110.
SALES "NOCE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on
yo sa re form and coded City of Arlington#3101.
9
-- 09/11/2025
Applicant Signature Date Budding Official Date
CONDITIONS
3"concrete pad with seismic bracing attached.Provide electrical disconnect.Lutes shall be insulated;use of adhesive tapes are
prohibited.Adhere to approved appliance. Approved job copy shall be onsite for inspections;if applicable. Call for final inspection.
The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property
owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or
community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities
before commencing construction. The property owner shall ensure that the construction project complies with all applicable design
review requirements.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE
PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,
MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
09/11/2025 Processing/Technology $25.00
09/11/2025 Inspection $75.00
09/11/2025 Dryer Ducting $15.00
09/11/2025 Dhaust/VentsNent Fans $60.00
09/11/2025 Forced Air Heat<_100 BTU/h $15.00
09/11/2025 Heat Pump-Condensing Unit $25.00
09/11/2025 Mechanical Base $25.00
09/11/2025 Credit Card Service $720
Total Due: $247.20
Total Payment: $247.20
Balance Due: $0.00
CALL FOR INSPECTIONS
Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested, and whether you prefer morning or afternoon
INSPECTION INFORMATION Pass/Fail
i
RESIDENTIAL MECHANICAL APPLICATION
• Community and Economic Development
City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551
This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping.
Please fill out all pages of this application and include all information.
Type of Permit: 0 New Installation ❑ Addition/Alteration/Repair ❑ Gas Piping
Property Address:
8324 175th St NE, Arlington WA 98223 Project Valuation: $29,000.00
Lot#: Parcel ID No.: Preferred Contact: ❑ Owner 0 Contractor
Project Description:
Installing HISENSE: 3-ton heat pump system and venting
Owner Name: McBride Construction Home No.:
Email Address: dano@mcbrideconstruction.com Cell No.:
15100 8th Avenue Southwest Burien
MailingAddress: City: State: WA Zi :98166
Contractor Name: Karl Christensen Office No.:
Email Address: office@legacyoneheating.net Cell No.:
Mailing Address: 4403 Russell Road #111 City: Mukilteo State: WA zip: 98275
L&I Contractor License Number: LEGACOH845L3 Expiration Date:
• New gas piping requires a pressure test hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper Combustion air and venting required for all appliances
• A shut-off valve is required within 6 feet of all appliances
Gas Piping Information O Not Applicable
❑ CSST ❑ Brass ❑ Other
Proposed Piping Material:
❑ Black Steel ❑ Galvanized Steel
Proposed Piping Size: ❑ 1/2" ❑ 5/8" 713/4" ❑ 1" ❑ 11/2 ❑ 2"
Distance from Meter to furthest Appliance: Total BTU's of all Appliances:
Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan
review per Table 4-8 may be required for certain permits)
Type of Fixture No. of Cost per Unit Subtotal Model No.
Units
Additional Plan Review fees x $75.00 =
Air Conditioning Unit<_ 100 Btu h x $ 15.00 =
Air Conditioning Unit> 100 Btu h x $25.00 =
Air Conditioning Unit> 500 Btu/hp x $50.00 =
Air Handling Units 1 x $ 15.00 = $15.00 AUH-36UX3SDH2
Base Mechanical Fee 1 x $25.00 = $25.00
Boiler<100Btu h> hp x $ 15.00 =
REV03.2022 Page 1 of 3
Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan
review per Table 4-8 may be required for certain permits)
Boiler>1 million Btu/h<50hp x $25.00 =
Boiler>1.5 million Btu/h<50hp x $50.00 =
Boiler>100Btu h 3-15h x $ 15.00 =
Boiler>500Btu h 15-30hp x $25.00 =
Commercial Hoods-Type I x $25.00 =
Commercial Hoods-Type II x $50.00 =
Diffusers x $ 15.00 =
Dryer Ducting x $ 15.00 =
Ductwork(drawings required 1 x $25.00 = $25.00
Evaporative Coolers x $ 15.00 =
Exhaust/Ventilation Fans 4 x $ 15.00 = $60.00
Fireplace/Insert/Stove x $ 15.00 =
Forced Air Heat<_100 Btu h x $ 15.00 =
Forced Air Heat>100 Btu h x $25.00 =
Gas Clothes Dryer x $ 15.00 =
Gas Fired Air Conditioning Unit<_ 100 Btu h x $ 15.00 =
Gas Fired Air Conditioning Unit> 100 Btu h x $25.00 =
Gas Fired Air Conditioning Unit> 500 Btu/hp x $50.00 =
Gas Pipin <_5 units x $ 15.00 =
Gas Piping for each additional unit > 5 x $2.00 =
Heat Exchangers x $ 15.00 =
Heat Pump-Condensing Unit 1 x $25.00 = $25.00 AUWR-36U3SF2
Hot Water Heat Coils x $ 15.00 =
Miscellaneous Appliance-regulated by x $ 15.00
mechanical code,not otherwise specified
Package Units<_ 100 Btu > 100 Btu x $25.00 $50.00 =
Range/Cook top-Gas Fired x $ 15.00 =
Refrigeration Unit<_100Btu h x $ 15.00 =
Refrigeration Unit>100Btu h x $25.00 =
Refrigeration.Unit>500Btu h x $50.00 =
Re-inspection fee x $75.00 =
Residential Range Hood x $ 15.00 =
Unit Heaters<_ 100 Btu/h x $ 15.00 =
Unit Heaters>100 Btu/h x $25.00 =
Variable Air Volume Boxes (part of Air x $ 10.00
Conditioning System)
Wall Heaters-Gas Fired x $25.00 =
Water Heater-Gas Fired x $25.00 =
Permit Fee
Inspection Fee $75.00
Processing/Technology Fee $25.00
Total
I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of
the above described property will be in accordance with the laws,rules and regulation of the State of Washington.
Signature Print Name Date
REV2.2024 Page 2 of 3
PRESSURE PIPING SCHEMATIC
COMPLETE FOR GAS PIPING ONLY
❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE
Show Pipe Size(s) and Length(s) from meter to all appliances
NOTE: Any interior pressure regulators must be indicated
REV2.2024 Page 3 of 3
Hisense HVAC
Project Name: Approval:
Location: Date:
Engineer: Construction:
Submitted to: Unit#:
Submitted by: Drawin #:
Reference:
Description: Hi-Ultra, 3.0 Ton Multi-Position Air Handler, Heat
Pump
c(EtO.s � Hon
Greener
• Homes
11MA
:III' 1111�4'iljjllu
.71
lu„ �.;R'ullihlll
a111 I�,aill,l�lpq
ir•1p1��` i
Air Handler Model: Condensing Unit Model:
AUH-36UX3SDH2 AUWR-36U3SA2
KEY FEATURES
Air Handler Features Condensing Unit Features
0 Highly efficient totally enclosed 0 Easy installation for new
ECM motor. construction or retrofit application.
0 External static pressure: 0.80 Compatible with most of other
In.W.C.for 2Ton-5Ton. brands air handler or A-coil. No
0 Multi-position installation: horizontal need additional 24V interface
(left or right), vertical (up or down). module.
0 Optional electric heat kit for 0 Quieter outdoor with variable
additional heat capacity. speed compressor.
0 High anti-corrosion coils. 0 Low operating temp: -13°F(-25 °C)
0 Universal 24V 3rd party thermostat for heating, and 5 ° F(-15 ° C)for
is available. cooling.
0 Standard with Base Pan Heater to
melt the ice and snow.
0 Rating with Aspen indoor units in
AHRI: LEW36C4, LEW36D4,
LEM36F4
Hisense HVAC
TableESP - Air Flow
Airflow performance data is based on cooling performance with a
coil and no filter in place. Check the performance table for
appropriate unit size selection. External static pressure should
stay within the minimum and maximum limits shown in the table
below in order to ensure proper cooling, heating ,and electric
heating operation.
Bold outlined areas represent airflow outside of the required 300-
450 cfm/ton range.
Air Flow Table
External Static Pressure
Air in.H2O[KPa]
Handler Motor Speed
Model 0[0] 0.1[0.02] 0.18[0.045] 0.3[0.07] 0.4[0.1] 0.5[0.12] 0.6[0.15] 0.7[0.17] 0.8[0.20]
Tap(1) CFM 1264 1216 1172 1135 1096 1028 964 890 839
Default
Setting Watts 215 222 233 238 244 254 261 266 274
CFM 1350 1314 1269 1206 1116 1082 1050 990 930
Tap(2) Watts 1 257 264 1 274 282 1 292 297 302 309 316
36K
CFM 1460 1409 1368 1323 1266 1192 1122 1060 999
Tap(3) Watts 280 288 295 304 313 323 333 340 348
CFM 1526 1479 1441 1399 1350 1292 1221 1148 1088
Tap(4) Watts 342 348 355 363 371 1 381 1 394 1 401 406
Electric Heater
Air Electric MAX.Fuse or Breaker
Handler Heat MIN.Circuit Ampacity (HACR)Ampacity Fan Speed Tap
Model (kW)
230VAC 208VAC 230VAC 208VAC 2 3 4 5
HS-EH5 29.8 27.4 30 30 • • • •
HS-EH75 42.2 38.7 45 40 x • • •
36K BTU HS-EH10 54.7 49.9 60 50 x x • •
HS-EH15 42.2+36.9 1 38.6+33.8 1 45+40 1 40+35 1 x x I x •
Hisense HVAC
Technical Spec.
PERFORMANCE
DATA
Power supply I Ph-V-Hz I 208-230V,1 Ph,60Hz
Cooling
Capacity Btu/h 34000
Input W 3370
Capacity(min-max) Btu/h 11800-36800
EER2 Btu/w 10.1
EER2 Btu/w 18
Heating
Capacity Btu/h 35000
Input W 3100
Capacity(min-max) Btu/h 8900-38200
COP2(47°F) WAN 3.5
HSPF2 Btu/w 9.5
COP @ 5F (@Max. Capacity) WAN 2.1
Electrical
MINIMUM CIRCUIT AMPACITY A 4.8
MAX. FUSE A 10
onnection wiring outdoor3x10,lndoor3x16 AWG
Compressor
ype Twin ROTARY
Brand GMCC
Rated current(RLA) A 16.1
Locked rotor Amp(LRA) A ---
Thermal protector ---
Thermal protector position ---
Refrigerant oil/oil charge ml VG74/670
SYSTEM DATA
Design pressure PSIG 550/240
Refrigerant type oz R410A/98.7
Refrigerant precharge ft 25
Additional charge per ft. oz 0.38
Liquid side/Gas side mm(in) 09.52/019.05(3/8'/3/4')
Max. refrigerant pipe length ft 246
Max. difference in level ft. 98
ESP
ESP range in. wg. 0-0.8 (0-200)
Hisense HVAC
Technical Spec.
INDOOR UNIT
DATA
Indoor fan motor
Model ZWK70213500026
Type DC
Input 1/2
RLA A 3.6-3.8
LRA A ---
finding Resistance S2 ---
Capacitor uF ---
Speed(Hi/Mi/Lo) r/min 350-1400
Air flow& Noise level
Indoor air flow(Hi) CFM 1120
Indoor noise level (Hi dB(A) 57
Indoor unit
Dimension(W*H*D) inch 19-5/8 x 46-1/8 x 21-5/8
Packing (W*H*D) inch 22-1/2 x 49-5/8 x 25-3/8
Net/Gross weight lbs. 140/163.1
OUTDOOR UNIT DATA
Outdoor fan motor
Model SIC-71 FW-D8121-1
Type DC
Input 121
RLA A 1
LRA A ---
finding Resistance 0 ---
Capacitor uF I ---
Speed r/min 810
Air flow& Noise level
Outdoor air flow CFM 2350
Outdoor noise level dB(A) 57
Outdoor unit
Dimension(W*D*H) inch 37-3/8x33x13-3/8
Packing (W*D*H) inch 43-3/4x36-1/4x18-1/8
Net/Gross weight lbs. 147.7/158.7
Operation temperature
Indoor(cooling/heating) Deg. F 62-90/32-86
Outdoor(cooling/heating) Deg. F 5-118/-4-75
Hisense HVAC
DIMENSIONALDRAWING
Air Handier
Unit: inch(mm)
Ai,outlet
2(51)
® I
m
Electric box
Gas pipe
Liquid pip.
N a
v Drain pipe
3-1/4(81) 1-3/8(35) 2H/8(550)
19-5/8(500)
Air inlet
0
zt
b
N
N
b
Hisense HVAC
DIMENSIONAL DRAWING
Condensing Units
Unit: inch(mm)
Electric box
---------------
i
M
Ci
Gas pipe o
Emu
Li uid i e
0
�N
�O ,
v
61/8 7-114(185) I 22-7/8(580)
1-518(66) {155) 3-112
37-318(950) �
40-71K1038Q
13-911 344
Drai^pipe Air inlet
a �
4 M
E-,
L 2 3/4
4-0 5/415)HOIe Air outlet (70)
a.
r
1�
P p r- t Y line
8328
01
1� f�
Permit#: 6705
Permit Date: 09/09/25
Permit Type: RESIDENTIAL MECHANICAL
Project Name: Village Housing 3
Applicant Name: Legacy One Heating
Applicant Address: 4403 Russell Road#I I I
Applicant, City, State, Zip: Mukilteo,WA 98275
Contact: Karl Christensen
Phone: 4253747052
Email: office@legacyoneheating.net
Scope of Work: Install HISENSE: 3-ton heat pump system
Valuation: 29000.00
Square Feet: 2140
Number of Stories: 1
Construction Type: VB
Occupancy Group: R-3; Residential
ID Code:
Permit Issued: 09/11/2025
Permit Expires: 03/10/2026
Form Permit Type: RESIDENTIAL MECHANICAL
Status: ISSUED
Assigned To: Hannah Hardwick
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
O'NEILL 100 SINGLE
00958500000500 8324 175TH ST NE GREGORY J& FAMILY
CAROL L RESIDENCE
Contractors
Contractor Primary Contact Phone Address Contractor Type License License#
Legacy One Heating Karl Christensen 4403 Russell CONSTRUCTION
Road#111 CONTRACTOR UBI 604006069
4403 Russell CONSTRUCTION Construction
Legacy One Heating Karl Christensen LEGACOH845L3
Road#111 CONTRACTOR Contractor
Inspections
Date Inspection Type Description Scheduled Date Completed Date Inspector Status
C14. Please contact Dan
03/03/2026 MECHANICAL O'Connor for an ETA if 03/09/2026 03/05/2026 BUILDING Approved
FINAL provided.(206)402-9496
R08.
03/02/2026 MECHANICAL 09/02/2025 BUILDING Approved
ROUGH-IN
Fees
Fee Description Notes Amount
Processing/Technology $25.00
Inspection $75.00
Dryer Ducting Enter#of units $15.00
ExhaustNentsNent Fans $60.00
Forced Air Heat<100 BTU/h Enter#of units $15.00
Heat Pump-Condensing Unit Enter#of units $25.00
Mechanical Base Permit Fee $25.00
Credit Card Service $7.20
Total $247.20
Attached Letters
Date Letter Description
09/11/2025 Building Permit
09/09/2025 Web Form-Residential Mechanical Application
Payments
Date Paid By Description Payment Type Accepted By Amount
09/09/2025 Mikell Christensen 242433875 Hannah Hardwick $7.20
09/09/2025 XBP Con£ $240.00
242433875
Outstanding Balance $0.00
Notes
Date Note Created By:
03/02/2026 sent expiration notice Hannah Hardwick
02/02/2026 Expiration notice sent LaNay Hendrick
09/09/2025 emailed for site plan Hannah Hardwick
Uploaded Files
Date File Name
09/11/2025 28214706-2025 BLD6705 Issued Permit.pdf
09/11/2025 28214302-20250911 BLD6705 Site Plan.pdf
09/09/2025 46ec6fab7238f86e5ba3a6f5a234d8bb hi-ultra hd 3t idu.pdf
09/09/2025 f22ddf9fld8bbld0edfbbac8b78cb823 20815635-residential mechanical.pdf