Loading...
HomeMy WebLinkAbout8324 175TH ST NE_BLD6705_2026 CITY OF ARLINGTON 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center:360-403-3551 BUILDING PERMIT 8324 175TH ST NE Permit#: 6705 Parcel#:00958500000500 PERMIT EXPIRES 180 DAYS AFTER DATE OF ISSUANCE. Scope of Work:Install HISENSE:3-ton heat pump system Valuation:29000.00 OWNER APPLICANT CONTRACTOR O'NEILL GREGORY J&CAROL L Legacy One Heating Legacy One Heating 8324 175TH ST NE 4403 Russell Road#111 4403 Russell Road#111 ARLINGTON,WA 98223-4051 Muldheo,WA 98275 Mukilteo,WA 98275 4253747052 LIC:604 006 069 EXP:09/30/2026 LIC:LEGACOH84513 EXP:06/23/2026 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: RESIDENTIAL MECHANICAL CODE YEAR: 2021 STORIES: I CONST.TYPE: VB DWELLING UNITS: OCC GROUP: R-3;Residential BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1 10/IRC110. SALES "NOCE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on yo sa re form and coded City of Arlington#3101. 9 -- 09/11/2025 Applicant Signature Date Budding Official Date CONDITIONS 3"concrete pad with seismic bracing attached.Provide electrical disconnect.Lutes shall be insulated;use of adhesive tapes are prohibited.Adhere to approved appliance. Approved job copy shall be onsite for inspections;if applicable. Call for final inspection. The property owner shall ensure that the construction project complies with all applicable zoning codes and regulations. The property owner shall also ensure that the construction project does not cause any adverse impact on the surrounding environment or community.The property owner shall be responsible for obtaining all necessary permits and approvals from the relevant authorities before commencing construction. The property owner shall ensure that the construction project complies with all applicable design review requirements. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/11/2025 Processing/Technology $25.00 09/11/2025 Inspection $75.00 09/11/2025 Dryer Ducting $15.00 09/11/2025 Dhaust/VentsNent Fans $60.00 09/11/2025 Forced Air Heat<_100 BTU/h $15.00 09/11/2025 Heat Pump-Condensing Unit $25.00 09/11/2025 Mechanical Base $25.00 09/11/2025 Credit Card Service $720 Total Due: $247.20 Total Payment: $247.20 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested, and whether you prefer morning or afternoon INSPECTION INFORMATION Pass/Fail i RESIDENTIAL MECHANICAL APPLICATION • Community and Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223 • Phone(360) 403-3551 This application is for new, addition, altered or replaced mechanical installation and new or altered gas piping. Please fill out all pages of this application and include all information. Type of Permit: 0 New Installation ❑ Addition/Alteration/Repair ❑ Gas Piping Property Address: 8324 175th St NE, Arlington WA 98223 Project Valuation: $29,000.00 Lot#: Parcel ID No.: Preferred Contact: ❑ Owner 0 Contractor Project Description: Installing HISENSE: 3-ton heat pump system and venting Owner Name: McBride Construction Home No.: Email Address: dano@mcbrideconstruction.com Cell No.: 15100 8th Avenue Southwest Burien MailingAddress: City: State: WA Zi :98166 Contractor Name: Karl Christensen Office No.: Email Address: office@legacyoneheating.net Cell No.: Mailing Address: 4403 Russell Road #111 City: Mukilteo State: WA zip: 98275 L&I Contractor License Number: LEGACOH845L3 Expiration Date: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Gas Piping Information O Not Applicable ❑ CSST ❑ Brass ❑ Other Proposed Piping Material: ❑ Black Steel ❑ Galvanized Steel Proposed Piping Size: ❑ 1/2" ❑ 5/8" 713/4" ❑ 1" ❑ 11/2 ❑ 2" Distance from Meter to furthest Appliance: Total BTU's of all Appliances: Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Type of Fixture No. of Cost per Unit Subtotal Model No. Units Additional Plan Review fees x $75.00 = Air Conditioning Unit<_ 100 Btu h x $ 15.00 = Air Conditioning Unit> 100 Btu h x $25.00 = Air Conditioning Unit> 500 Btu/hp x $50.00 = Air Handling Units 1 x $ 15.00 = $15.00 AUH-36UX3SDH2 Base Mechanical Fee 1 x $25.00 = $25.00 Boiler<100Btu h> hp x $ 15.00 = REV03.2022 Page 1 of 3 Residential mechanical permits will be assessed a base fee, fee per unit, and inspection fee (plan review per Table 4-8 may be required for certain permits) Boiler>1 million Btu/h<50hp x $25.00 = Boiler>1.5 million Btu/h<50hp x $50.00 = Boiler>100Btu h 3-15h x $ 15.00 = Boiler>500Btu h 15-30hp x $25.00 = Commercial Hoods-Type I x $25.00 = Commercial Hoods-Type II x $50.00 = Diffusers x $ 15.00 = Dryer Ducting x $ 15.00 = Ductwork(drawings required 1 x $25.00 = $25.00 Evaporative Coolers x $ 15.00 = Exhaust/Ventilation Fans 4 x $ 15.00 = $60.00 Fireplace/Insert/Stove x $ 15.00 = Forced Air Heat<_100 Btu h x $ 15.00 = Forced Air Heat>100 Btu h x $25.00 = Gas Clothes Dryer x $ 15.00 = Gas Fired Air Conditioning Unit<_ 100 Btu h x $ 15.00 = Gas Fired Air Conditioning Unit> 100 Btu h x $25.00 = Gas Fired Air Conditioning Unit> 500 Btu/hp x $50.00 = Gas Pipin <_5 units x $ 15.00 = Gas Piping for each additional unit > 5 x $2.00 = Heat Exchangers x $ 15.00 = Heat Pump-Condensing Unit 1 x $25.00 = $25.00 AUWR-36U3SF2 Hot Water Heat Coils x $ 15.00 = Miscellaneous Appliance-regulated by x $ 15.00 mechanical code,not otherwise specified Package Units<_ 100 Btu > 100 Btu x $25.00 $50.00 = Range/Cook top-Gas Fired x $ 15.00 = Refrigeration Unit<_100Btu h x $ 15.00 = Refrigeration Unit>100Btu h x $25.00 = Refrigeration.Unit>500Btu h x $50.00 = Re-inspection fee x $75.00 = Residential Range Hood x $ 15.00 = Unit Heaters<_ 100 Btu/h x $ 15.00 = Unit Heaters>100 Btu/h x $25.00 = Variable Air Volume Boxes (part of Air x $ 10.00 Conditioning System) Wall Heaters-Gas Fired x $25.00 = Water Heater-Gas Fired x $25.00 = Permit Fee Inspection Fee $75.00 Processing/Technology Fee $25.00 Total I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above described property will be in accordance with the laws,rules and regulation of the State of Washington. Signature Print Name Date REV2.2024 Page 2 of 3 PRESSURE PIPING SCHEMATIC COMPLETE FOR GAS PIPING ONLY ❑ SCHEMATIC IS TO SCALE ❑ SCHEMATIC NOT TO SCALE Show Pipe Size(s) and Length(s) from meter to all appliances NOTE: Any interior pressure regulators must be indicated REV2.2024 Page 3 of 3 Hisense HVAC Project Name: Approval: Location: Date: Engineer: Construction: Submitted to: Unit#: Submitted by: Drawin #: Reference: Description: Hi-Ultra, 3.0 Ton Multi-Position Air Handler, Heat Pump c(EtO.s � Hon Greener • Homes 11MA :III' 1111�4'iljjllu .71 lu„ �.;R'ullihlll a111 I�,aill,l�lpq ir•1p1��` i Air Handler Model: Condensing Unit Model: AUH-36UX3SDH2 AUWR-36U3SA2 KEY FEATURES Air Handler Features Condensing Unit Features 0 Highly efficient totally enclosed 0 Easy installation for new ECM motor. construction or retrofit application. 0 External static pressure: 0.80 Compatible with most of other In.W.C.for 2Ton-5Ton. brands air handler or A-coil. No 0 Multi-position installation: horizontal need additional 24V interface (left or right), vertical (up or down). module. 0 Optional electric heat kit for 0 Quieter outdoor with variable additional heat capacity. speed compressor. 0 High anti-corrosion coils. 0 Low operating temp: -13°F(-25 °C) 0 Universal 24V 3rd party thermostat for heating, and 5 ° F(-15 ° C)for is available. cooling. 0 Standard with Base Pan Heater to melt the ice and snow. 0 Rating with Aspen indoor units in AHRI: LEW36C4, LEW36D4, LEM36F4 Hisense HVAC TableESP - Air Flow Airflow performance data is based on cooling performance with a coil and no filter in place. Check the performance table for appropriate unit size selection. External static pressure should stay within the minimum and maximum limits shown in the table below in order to ensure proper cooling, heating ,and electric heating operation. Bold outlined areas represent airflow outside of the required 300- 450 cfm/ton range. Air Flow Table External Static Pressure Air in.H2O[KPa] Handler Motor Speed Model 0[0] 0.1[0.02] 0.18[0.045] 0.3[0.07] 0.4[0.1] 0.5[0.12] 0.6[0.15] 0.7[0.17] 0.8[0.20] Tap(1) CFM 1264 1216 1172 1135 1096 1028 964 890 839 Default Setting Watts 215 222 233 238 244 254 261 266 274 CFM 1350 1314 1269 1206 1116 1082 1050 990 930 Tap(2) Watts 1 257 264 1 274 282 1 292 297 302 309 316 36K CFM 1460 1409 1368 1323 1266 1192 1122 1060 999 Tap(3) Watts 280 288 295 304 313 323 333 340 348 CFM 1526 1479 1441 1399 1350 1292 1221 1148 1088 Tap(4) Watts 342 348 355 363 371 1 381 1 394 1 401 406 Electric Heater Air Electric MAX.Fuse or Breaker Handler Heat MIN.Circuit Ampacity (HACR)Ampacity Fan Speed Tap Model (kW) 230VAC 208VAC 230VAC 208VAC 2 3 4 5 HS-EH5 29.8 27.4 30 30 • • • • HS-EH75 42.2 38.7 45 40 x • • • 36K BTU HS-EH10 54.7 49.9 60 50 x x • • HS-EH15 42.2+36.9 1 38.6+33.8 1 45+40 1 40+35 1 x x I x • Hisense HVAC Technical Spec. PERFORMANCE DATA Power supply I Ph-V-Hz I 208-230V,1 Ph,60Hz Cooling Capacity Btu/h 34000 Input W 3370 Capacity(min-max) Btu/h 11800-36800 EER2 Btu/w 10.1 EER2 Btu/w 18 Heating Capacity Btu/h 35000 Input W 3100 Capacity(min-max) Btu/h 8900-38200 COP2(47°F) WAN 3.5 HSPF2 Btu/w 9.5 COP @ 5F (@Max. Capacity) WAN 2.1 Electrical MINIMUM CIRCUIT AMPACITY A 4.8 MAX. FUSE A 10 onnection wiring outdoor3x10,lndoor3x16 AWG Compressor ype Twin ROTARY Brand GMCC Rated current(RLA) A 16.1 Locked rotor Amp(LRA) A --- Thermal protector --- Thermal protector position --- Refrigerant oil/oil charge ml VG74/670 SYSTEM DATA Design pressure PSIG 550/240 Refrigerant type oz R410A/98.7 Refrigerant precharge ft 25 Additional charge per ft. oz 0.38 Liquid side/Gas side mm(in) 09.52/019.05(3/8'/3/4') Max. refrigerant pipe length ft 246 Max. difference in level ft. 98 ESP ESP range in. wg. 0-0.8 (0-200) Hisense HVAC Technical Spec. INDOOR UNIT DATA Indoor fan motor Model ZWK70213500026 Type DC Input 1/2 RLA A 3.6-3.8 LRA A --- finding Resistance S2 --- Capacitor uF --- Speed(Hi/Mi/Lo) r/min 350-1400 Air flow& Noise level Indoor air flow(Hi) CFM 1120 Indoor noise level (Hi dB(A) 57 Indoor unit Dimension(W*H*D) inch 19-5/8 x 46-1/8 x 21-5/8 Packing (W*H*D) inch 22-1/2 x 49-5/8 x 25-3/8 Net/Gross weight lbs. 140/163.1 OUTDOOR UNIT DATA Outdoor fan motor Model SIC-71 FW-D8121-1 Type DC Input 121 RLA A 1 LRA A --- finding Resistance 0 --- Capacitor uF I --- Speed r/min 810 Air flow& Noise level Outdoor air flow CFM 2350 Outdoor noise level dB(A) 57 Outdoor unit Dimension(W*D*H) inch 37-3/8x33x13-3/8 Packing (W*D*H) inch 43-3/4x36-1/4x18-1/8 Net/Gross weight lbs. 147.7/158.7 Operation temperature Indoor(cooling/heating) Deg. F 62-90/32-86 Outdoor(cooling/heating) Deg. F 5-118/-4-75 Hisense HVAC DIMENSIONALDRAWING Air Handier Unit: inch(mm) Ai,outlet 2(51) ® I m Electric box Gas pipe Liquid pip. N a v Drain pipe 3-1/4(81) 1-3/8(35) 2H/8(550) 19-5/8(500) Air inlet 0 zt b N N b Hisense HVAC DIMENSIONAL DRAWING Condensing Units Unit: inch(mm) Electric box --------------- i M Ci Gas pipe o Emu Li uid i e 0 �N �O , v 61/8 7-114(185) I 22-7/8(580) 1-518(66) {155) 3-112 37-318(950) � 40-71K1038Q 13-911 344 Drai^pipe Air inlet a � 4 M E-, L 2 3/4 4-0 5/415)HOIe Air outlet (70) a. r 1� P p r- t Y line 8328 01 1� f� Permit#: 6705 Permit Date: 09/09/25 Permit Type: RESIDENTIAL MECHANICAL Project Name: Village Housing 3 Applicant Name: Legacy One Heating Applicant Address: 4403 Russell Road#I I I Applicant, City, State, Zip: Mukilteo,WA 98275 Contact: Karl Christensen Phone: 4253747052 Email: office@legacyoneheating.net Scope of Work: Install HISENSE: 3-ton heat pump system Valuation: 29000.00 Square Feet: 2140 Number of Stories: 1 Construction Type: VB Occupancy Group: R-3; Residential ID Code: Permit Issued: 09/11/2025 Permit Expires: 03/10/2026 Form Permit Type: RESIDENTIAL MECHANICAL Status: ISSUED Assigned To: Hannah Hardwick Property Parcel# Address Legal Description Owner Name Owner Phone Zoning O'NEILL 100 SINGLE 00958500000500 8324 175TH ST NE GREGORY J& FAMILY CAROL L RESIDENCE Contractors Contractor Primary Contact Phone Address Contractor Type License License# Legacy One Heating Karl Christensen 4403 Russell CONSTRUCTION Road#111 CONTRACTOR UBI 604006069 4403 Russell CONSTRUCTION Construction Legacy One Heating Karl Christensen LEGACOH845L3 Road#111 CONTRACTOR Contractor Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status C14. Please contact Dan 03/03/2026 MECHANICAL O'Connor for an ETA if 03/09/2026 03/05/2026 BUILDING Approved FINAL provided.(206)402-9496 R08. 03/02/2026 MECHANICAL 09/02/2025 BUILDING Approved ROUGH-IN Fees Fee Description Notes Amount Processing/Technology $25.00 Inspection $75.00 Dryer Ducting Enter#of units $15.00 ExhaustNentsNent Fans $60.00 Forced Air Heat<100 BTU/h Enter#of units $15.00 Heat Pump-Condensing Unit Enter#of units $25.00 Mechanical Base Permit Fee $25.00 Credit Card Service $7.20 Total $247.20 Attached Letters Date Letter Description 09/11/2025 Building Permit 09/09/2025 Web Form-Residential Mechanical Application Payments Date Paid By Description Payment Type Accepted By Amount 09/09/2025 Mikell Christensen 242433875 Hannah Hardwick $7.20 09/09/2025 XBP Con£ $240.00 242433875 Outstanding Balance $0.00 Notes Date Note Created By: 03/02/2026 sent expiration notice Hannah Hardwick 02/02/2026 Expiration notice sent LaNay Hendrick 09/09/2025 emailed for site plan Hannah Hardwick Uploaded Files Date File Name 09/11/2025 28214706-2025 BLD6705 Issued Permit.pdf 09/11/2025 28214302-20250911 BLD6705 Site Plan.pdf 09/09/2025 46ec6fab7238f86e5ba3a6f5a234d8bb hi-ultra hd 3t idu.pdf 09/09/2025 f22ddf9fld8bbld0edfbbac8b78cb823 20815635-residential mechanical.pdf