HomeMy WebLinkAbout17721 35th Ave Ne_BLD2699_2026 NOTICE TO PERMITEE AND/OR OWNER Cl PARTIAL APPROVAL nCORRECTIONS REQUIRED ❑ DO NOT OCCUPY ❑APPROVED PERMIT#: to q AM PM DATE: - - O JOB ADDRESS: LOT#: PROJECT:_V►-61 P4 m,,_A C k 4,c., TYPE OF INSPECTION: F,`re-A" Fi A JI OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION S-4Yr�b� c,n. s ,iL ;s ;AJ*.��ee� �0 1�:31� S4Y+dlx ray c_ �� r'MfZrtger as e� !-/3-2oao THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE Cl PLANNING O CIVIL Cl BUILDING CITY OF ARLINGTON (41 r -r .- � I i ' -i = l i II � �r . y i - � ' L -- ' _ . _ I r i �� CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 4P PHONE; (360) 403-3551 BUILDING PERMIT Address:17721 Smokey Point Blvd Permit#:2699 Parcel#:31052100301800 Valuation:4500.00 OWNER APPLICANT CONTRACTOR Name:CHRISTIAN&MISSIONARY Name:Olympic Security&Communication Name:OLYMPIC SECURITY ALLIANCE-ARLINGTON Address: 17721 SMOKEY POINT BLVD Address:PO Box 3559 Address:PO BOX 3559 City,State Zip:ARLINGTON,WA 98223 City,State Zip:Arlington,WA 98223 City,State Zip:Arlington,WA 98223 Phone: Phone:360-652-1088 Phone:360-652-1089 LIC: EXP: MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Olympic Security Name: Address:PO Box 3559 Address: City,State,Zip:Arlington,WA 98223 City,State,Zip: Phone:360-652-1088 Phone: LIC#:OLYMPSC012QP EXP: 11/17/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFI ATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRC110. _�ALES T T &Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and code ty f rlington ol. p /� �! Z 7 A naturc Print Name Date Released By Dat CONDITIONS 1. Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request. 2. Battery load test required, switch system to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for initiation, notification and signaling circuits. 4. Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). 5. The record of completion form shall be submitted prior to project close-out. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 09/17/2019 Fire Alarm Plan Review Fee $100.00 09/17/2019 Fire Permit Fee $162.56 09/17/2019 Processing/Technology Fee $25.00 Total Due: $287.56 Total Payment: $0.00 Balance Due: $287.56 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit Information Date 8/1/2019 Permit Number 2699 Project Name Smokey Point Community Church Fire Alarm Applicant Name Olympic Security&Communication Applicant Address PO Box 3559 City, State,Zip Arlington,WA 98223 Contact Vikki Ryason Phone 360-652-1088 Email vkki@olympicsecurity.com;tom@olympicsecurity.com Permit Type Fire Alarm Site Address 17721 Smokey Point Blvd Valuation 4500.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Commercial Fire Alarm Alteration Number of Stories 0 Proposed Use Install AES Radio MIC/Opportunity Zone Opportunity Zone Assigned To Raelynn Jones Property Owner Parcel Address Le al Owner Phone Zoning 31052100301800 17721 35TH AVE CHRISTIAN&MISSIONARY ALLIANCE- 699 Other Miscellaneous Services NE ARLINGTON NEC Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# OLYMPIC SECURITY 360-652-1088 uth systems ecialties.com rONTRACTOR abor&Industries OLYMPSC012QP Review Date Type Descri tion Target Date Completed-bate-1 Assigned To Status /1/2019 =ire Alarm /15/2019 IBuilding In Review 3/1/2019 Fire Alarm /15/2019 IFire In Review Fees Fee Description Notes Amount Fire Alarm Plan Review Fee 345.83.00.00 $100.00 Fire Permit Fee 322.10.00.00 $162.56 Processing/Technology Fee 341.43.00.02 $25.00 Total $287,561 Notes Date Note 8/1/2019 Applicant indicated that the submitted plans are to scale. Uploaded Files Upload File Date File Uploaded B 8/1/2019 11:46 06 AM 12699 Application.pdf lJones, Raelynn �`�' °� FI' : ALARM PERMIT APPLICATION << r+ Department of Community&Economic Development City of Arlington•18204 59th Ave NE•WA 98223•Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO,INCLUDE SPECIFICATION SHEETS,WIRING DIAGRAMS,(POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit:(check one) F.971__ Fire Alarm Alteration/Addition. . Project Address: Parcel ID#: P Number of Zones/Panels: Build�g Area( q Ft):��76��y Valuation: � Owner:e';7�Gxey <<✓" Phone Number: Address: ` L y/� / C,ty. State. Zip Code: Contact Person: Phone Number: 2,06 717 ���� Cell Phone: Email: Address: City: Slate: Zip/Code: Contractor: /r7S• Phone Number: �t�r 6S2-°AOLL Address: " 7 / n City: ��L N State: Zip Code: dW2Z 51 Contractor'sLic / en.s/eNumber. f��Y/')'J/aSC�/Z ExpiralOn: r� vZpj Contact Person: s+'Y1 r�ac16vo� Email:_f Oft Electrical Contractor: Phone Number: Address' City: State: Zip Code: Contractor's License Number: Expiration: I hereby cedily the above information is correct and that lire construction on,and the occupancy and the use of the above described property will be accord Ih tho laws,rules and regulations of the State of Washington. d1'Yl 7 i1 -l ApplicaiTts S-i�rw_tura Date Print Applicants Name FOR STAFF USE ONLY 1 00 40CA Q _ JUL 31201. Permit# By Amount Received Receip[# Date Received WEB Form—130 Page 1 of 1 6/16LP i i � i! Home Espafiol Contact Search L&ISEARCH A-Zhidex Labor Safety&Health Claims&Insurance Workplace Rights n- Trades&Licensing Washington State Department of " Labor & industries OLYMPIC SEC&COMM SYS INC Owner or tradesperson PO BOX 3559 Principals ARLINGTON,WA 98223 BROWN,TOM D,PRESIDENT 360-652-1088 SNOHOMISH County BROWN,SANDRA D,VICE PRESIDENT BROWN,TOM D,AGENT Doing business as OLYMPIC SEC&COMM SYS INC WA UBI No. Business type 601 981 540 Corporation Governing persons SANDRA D BROWN TOM D JR BROWN; Certifications & Endorsements License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Electrical Contractor Active. Meets current requirements. License specialties LIMITED ENERGY License no. OLYMPSC012QP Effective—expiration 11/17/1999-11/17/2019 Designated administrator Active. BROWN,TOM D Meets current requirements. License type License no. Master Electrician BROWNTD936BE Bond United States Fire Insurance Co $4,000.00 Bond account no. 615981521 Received by L&I Effective date 11/07/2012 11/17/2012 Expiration date Until Canceled OLD REPUBLIC SURETY CO $4,000.00 Bond account no. Helpimprove YLI238881 Effective date 11/1 711 9 9 9 Expiration date Until Canceled Savings ................. .... No savings accounts during the previous 6 year period. License Violations Infraction no. EMIND00409 Satisfied Issue date RCW/WAC 05/09/2019 WAC 296-46B-901(5) Violation city Violation amount ARLINGTON $250.00 Type of violation ELECTRICAL CITATION Description Failing to obtain an electrical/telecommunications work permit and post the permit or permit number on the jobsite,or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration. Infraction no. ECOXE01044 Satisfied Issue date RCW/WAC 02/22/2016 19.28.161 RCW Violation city Violation amount ARLINGTON $250.00 Type of violation ELECTRICAL CITATION Description Failing to provide proper supervision to an electrical trainee as required by chapter 19.28 RCW. Infraction no. ECOXE01043 Satisfied Issue date RCW/WAC 02/22/2016 19.28.271 RCW Violation city -Violation-amount- ARLINGTON $250.00 Type of violation ELECTRICAL CITATION Description Employing an individual for the purposes of chapter 19.28 RCW who does not possess a valid certificate of competency or training certificate to do electrical work. Workers' comp Public Works Requirements Workplace safety and health City of Arlington Department September 5, 2019 Permit Number: BLD 2699 Project Address: 17721 Smokey Point Blvd, Arlington Project Description: Fire Alarm Installation (Revised)—Auditorium at Smokey Point Community Church Contractor: Vikki Ryason Olympic Security&Communication PO Box 3559 Arlington, WA 98223 Re: Fire Alarm Shop Drawing Review Comments—Approved The Arlington Fire Department has completed a review of the revised Fire Alarm shop drawing and approves the re- submittal with the following conditions: 1 Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request. 2 Battery load test required, switch system to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for initiation, notification and signaling circuits. 4. Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection (NFPA 72 Section 7.5.2). 5 The record of completion form shall be submitted prior to project close-out. Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the system at project completion. Final approval will not be provided until all conditions are verified. Call at least 48 hours in advance to schedule an inspection. If there are any questions please do not hesitate to call. Sincerely, 2"7)We& Mike Makela Assistant Fire Chief Arlington Fire Department COPY OFFICE ,F'1 i � �� •�r 4 i ` � Honeywell I Addressable Fire Alarm Control Panels ®SILENI" &NIGHT 6700 Addressable Fire Alarm Control Panel The 6700 is an addressable fire alarm control panel(FACP)that is a direct replacment for the 5700 FACP.The 6700 can be configured to achieve a point capacity of up to 100 points.It has one built-in 0 signaling line circuit(SLC),which can support 50 System Sensorw,(SK) sensors and 50 SK modules or 50 Hochiki"(SD)devices. dii". A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable.A designated panel is configured as the communicator for all panels in the link for convenient single-point communications.The 6700 also has a built-in, dual-line POTS and IP communicator with additional cellular options available. 6 700 The 6700 system can be enhanced by adding modules such as the The 6700 supports a variety of devices,including 6860 remote annunciator which also has four programmable function the 6860,5860,and 6855 remote annunciators, buttons to help automate tasks and reduce time spent at the panel. 5824 serial parallel printer interface module(for p ' SWIFT"wireless compatibility provides options forwireless detection 5 I 01 Y erGi Fulc,-,RM GTiN through a Class A mesh network.It is ideal for hard-to-wire locations, BUILDING DEPARTMENT buildings where new wiring is not allowed,or to provide an easy install APPROVED fire system for new construction projects.SWIFT devices can be combined with other hard-wired 6700 compatible devices.SWIFT is DATE, BY only compatible with System Sensor(SK)devices.It is not compatible with Hochiki(SD)devices. NO CHANGES AUTHORIZED UNLESS APPROVED BY THE The 6700 also has a form-C trouble relay,two programmable form-C BUILDING INSPECTOR relays,along with powerful features such as drift compensation,pre- trouble maintenance alert,a built-in sensor test to comply with NFPA 72 calibration testing requirements,and calibration trouble alert. OFFICE COPY • Capable of providing • Convenient • 6860 annUnCitItOr with Programmable date 125 software zones up to 100 points to field-upgradeable a 4 x 40 large display setting for automatic and 125 output satisfy smaller firmware • Four user- and convenient groups forflexible installation needs Daylight Saving Time design options • Built-in dual path programmable buttons • Connect up to 17 POTS and IP minimize time spent changes panels on one site with communications executing complex or JumpStart` auto convenient single- with optional cellular routine tasks programming reduces point access using the models available for guilt-in USB interface installation time SK--NIC Network reliable backup forconvenient and Interface Card, reporting quick programming Connected panels can have mixed compatible FACP models SIGNAL LINE CIRCUIT(SLC) PROGRAMMING ORDERING INFORMATION The 6700 SLC loops support multiple The 6700 system offers several options 6700:Addressable Fire Alarm device types,maintenance alerts,and a to simplify and speed-up programming. Control Panel.(Red cabinet) built-in sensor test to comply with NFPA JumpStartc'auto programming 72 calibration testing requirements. minimizes programming required to COMPATIBLE ANNUNCIATORS start a new system.The built-in keypad, 6860:4x40 LCD remote fire INDICATOR LIGHTS annunciator(4 lines and up to or the 6860,5860 or 6855 remote • General Alarm(Red):Flashes if in annunciators give you on-site access to 160 characters)per system;four alarm;solid when alarm is silenced current system programming. programmable buttons • Supervisory(Yellow):Flashes if a Programming can also be accomplished 5860:4x20 LCD remote fire supervisory condition exists;solid using the Windows-based Honeywell annunciator.5860 is gray;586OR is red when supervisory is silenced Fire Software Suite(HFSS)program. 6855:4x20 LCD remote fire • System Trouble(Yellow):Flashes annunciator SOFTWARE TOOLS 5865-3 or 5865-4:LED annunciators if a trouble condition exists; SKST:Silent Knight Selection Tool solid when trouble is silenced can display up to 30 LEDs(15 red and provides the installer or design architect 15 yellow).The 5865-4 has key switches • System Silenced(Yellow): with a Windows"software system for silence and reset,and a system On when an alarm,trouble or configuration tool to create a detailed trouble LED. supervisory condition has been Bill of Material(BOM)and battery silenced but notyet cleared 5880:The 5880 LED/10 module calculations. has 40 programmable LED outputs • System Power(Green):Flashes HFSS:Honeywell Fire Software Suite and eight supervised dry contact forAC failure;solid when provides communication and panel inputs which are useful for custom power systems are normal programming,detector status,event applications.You can use up to eight - �----- ^-his"nd additional data. Requires a 5880 modules on one control panel for USERINTERFQCE . PCrun'ingMicrosoft"Windows. maximum flexibility.Its compact size The 6700 built-in 4 x 20 annunciator with 80 character LCD display ADDITI NAL INFORMATION allows mounting inside the annunciator, Twisted`unshielded air wire is or in an accessory cabinet. an large easy-to-use tactile ` '' , p tou head can be used fpr system recomMended.The 6700 also has 6700 COMPATIBLE DEVICES AND op StIbIl.p1durallrMing"nd"•`A' '•'�`�V� 13 pres t notification cadence patterns ACCESSORIES See the data sheets listed below for a ma enanci° It h'aS five LEDs fbr '- �``(includiljg ANSI 3.41). complete listing of the SK,SD or SWIFT atasupervisory,system f rouble,, devices. AGENCY LISTINGS AND APPROVALS Sys[.m silenced and systerr'1 power..' t1PFA 13,NFPA 15,NFPA 16,NFPA 70, 53623:SK Devices Data Sheet % 53624:SD Devices Data Sheet System operations include silencing NFPA 72:Cerilralsldlion;remote 35U614,35U616&350618:SWIFT alarms and troubles,resetting alarms Signaling;Local Protective Signaling wireless devices and the display of alarm troubles and Systems;Auxiliary Protected Premises For a complete and current listing of Unit;Water Deluge releasing service. compatible devices and accessories,visit memory.The system's non-volatile g g www.sitentknight.com event history buffer stores 1,000 Suitable for automatic,manual, Important: You cannot mix SK and SD events for viewing from the built- waterflow,sprinkler supervisory(DACT devices in the same fire alarm system. in or remote annunciator.System non-coded)signaling services operations can be initiated with a • UL Listed:S2766 mechanical firefighter's key or a . CSFM 7165-0559:0501 valid 4-to 7-digit operator's code. . FDNY COA#6250 Page 2 of 4—351607:13 9/26/2018 SK COMPATIBLE ADDRESSABLE B200S-LF(-IV,-WH):Low-Frequency WSK-WGI:Wireless Gateway DEVICES intelligent sounder base WSK-PHOTO:Wireless Photoelectric SK-ACCLIMATE:Multi criteria B20OS-LF:Low-frequency intelligent smoke detector photoelectric smoke detector with thermal sounder base WSK-PHOTO-T:Wireless Multi-criteria 135°F fixed temperature B224RB(-IV,-WH):Relay base photoelectric smoke detector with thermal SK-BEAM:Reflected beam smoke detector B224RB: Relay base detection(1350Ffixed temperature)and without test feature B224B1(-IV,-WH):Isolator base B51OW 4"base SK-BEAM-T:Reflected beam smoke B224BI: Isolator base WSK-HEAT:Wireless Heat,(135°F fixed detector with test feature temperature)and B51OW 4"base SK-CONTROL:Supervised control module DEVICES SD COMPATIBLE ADDRESSABLE WSK-HEAT-ROR:Wireless heat,ROR SK-CONTROL-6:Six circuit supervised SD505 6AB:Addressable 6"base (135°F fixed temperature)and B51OW 4" control module base SD B:Addressable 6"short circuit WSK-MONITOR:Wireless monitor module SK-DUCT:Photoelectric duct smoke isolatorator base detectorwith extended airspeed range WSK-RELAY:Wireless relay module SK-FIRE-CO:Four criteria fire and carbon SD505-6RB:Addressable 6"relay base W-USB:SWIFT Tools USB transceiver used monoxide detector SD505-6SB:Addressable 6"sounderbase for communication with SWIFT devices SK-HEAT:Fixed thermal detector(135°F) SD500-AIM:Addressable input module SK-HEAT-W:Fixed thermal detector (switch input) SBUS ACCESSORIES (13509,white SD500-ANM:Addressable notification 5496:A6 amp notification power expander module with four power-limited notification (135°F) SK-HEAT-ROR:Fixed rate of rise detector SD500-ARM: Addressable relay module appliance circuit outputs. SK- SD505-DTS-K: Remote test switch 5883:Relay interface.Provides 10 Form C (13 5°F),whhiteits HEAT :Fixed rate of rise detector and LED indicator for the SD505-DUCTR relays. 13 SK-HEAT-HT:Fixed high temperature SD505-DUCT:Addressable Duct Smoke 5824:Serial/Parallel printer interface Detector. module for printer connection. thermal detector(190°F) l with p SK-HEAT-HT-W:Fixed high temperature SD505-DUCTR:Addressable Duct 5895XL:Power supply th six Flex put"' , thermal detector(190°F),white Detector housing with relay base. circuits,and two Form C relays.Max.16 per SK-ISO:Fault isolator module SD505-HEAT:Absolute temperature heat system. detector.Trip point range from 5815RMK:Remote mounting kit. SK-MINIMON:Mini monitor module 1350E-150OF(OOC-370C). Dimensions 10 3/8"W x 10-3/16"H x 3"D SK-MONITOR:Monitor module SD500-LIM:Addressable Line isolator SK-MONITOR-2:Dual input monitor module COMMUNICATION OPTIONS module SD500-MIM:Addressable Mini input CELL-CAB-SK:Cellular communicator, SK-MON-10:10 input monitor module monitor module(switch input) metal enclosure with lock/key* SK-PHOTO:Photoelectric smoke detector SD505-PHOTO:Photoelectric smoke CELL-MOD:Cellular communicator,plastic SK-PHOTO-W:Photoelectric smoke detector enclosure* detector,white SD500-PS/-PSDA:Addressable Single or *Sole path,powered by panel. SK-PHOTO-T:Photoelectric smoke detector dual action pull station I PGSM-4G:Dual path fire alarm with thermal(1350Ffixed temperature) SD500-SDM:Addressable smoke detector communicator,cellular and/or IP(primary or module backup,selectable) SK-PHOTO-T-W:Photoelectric smoke SK-IP-2:Remote reporting via the Internet, detector with thermal(135°F fixed AUDIBLE/VISIBLE DEVICES Requires a VisorAlarm"'receiver at the central temperature),white These AV devices are all 2-wire.Color:"R" station SK-PHOTOR:Photoelectric detector with indicates red;"W"denotes white.For a remote test capability complete listing of Silent Knight AV devices MISC.ACCESSORIES SK-PHOTO-R-W:Photoelectric detector go to www.sitentknight.com. SK-NIC: Network Interface Card. Provides a with remote test capability,white common communications link for the 6700 SK-PULL-SA:Addressable single action CHSRVCHSWL:Wall chime/strobe g CHSCRL/CHSCWL:Ceiling chime/strobe SK-NIC-KIT:Installation Accessory Kit pull station g SK-FML:Fiber-Optic Multi Mode,transmitter SK-PULL-DA:Addressable dual action pull CHRL/CHWL:Wall chime p and receiver station HRL/HWL:Wall horn P2RL/P2WL:Wall horn/strobe SK-FSL:Fiber-Optic Single Mode SK-RELAY:Addressable relay module RBB:Remote battery box accessory cabinet SK-RELAY-6:Addressable Six relay control PC2RL/PC2WL:Ceiling horn/strobe for batteries that are too large to fit in the module SRVSWL:Wall strobe FACP cabinet.Dimensions:16"W x 10"H x SK-RELAYMON-2:Addressable Dual relay/ SCRL/SCWL:Ceiling strobe 6"D(406mm W x 254mm H x 152mm D). monitor module SPSCRL/SPSCWL:Ceiling speaker/strobe SK-SCK: Seismic Compliance Kit used to SK-ZONE:Addressable zone interface SPSRVSPSWL:Wall speaker/strobe securely fasten batteries to the fire panel module SPRVSPWL:Wall speaker SK-ZONE-6:Six zone interface module SPCRL/SPCWL:Ceiling speaker B300-6(-IV):6"base for SK-W Series 821OLP:6"mounting base SWIFT WIRELESS DEVICES 13501(-BL,-IV,-WHITE):4"flangeless base SWIFT is only compatible with B501:4"Flangeless mounting base System Sensor(SK)devices.It is not B200S(-IV,-WH):Intelligent sounder base compatible with Hochiki(SD)devices. B20OS:Intelligent sounder base Page 3 of 4—351607:13 9/26/2018 6700 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS(NACs) Ftexput',Honeywell', Two programmable circuits which can be JumpStart',Silent Knight", Overall Dimensions:12 71"W x 15.12"H x 3.33"D SWIFT',and System programmed individually as: ower- Sensor`are registered Weight:15 tbs. NACs:2.5A @27.4VDC per circuit, limited Color:Red p trademarks of Honeywell (with a panel maximum current of 2.5A) International Inc. Auxiliary Power Circuits:2.5A @ 27.4VDC per ENVIRONMENTAL circuit power-limited Hochiki'�is a registered , Operating Temperature:32°Fto120OF (0°Cto trademark ofHochiki 49°C) Corporation.Microsoft" Humidity:0 to 93%relative hurnidit (non- Supports Class B(Style 4)and Class A(Style 6 or 7) and Windows"are y configuration for the SLC registered trademarks of condensing) Microsoft Corporation. ELECTRICAL WIRING:See the product manual for wiring details This document is not 6700 Primary AC:120 VAC @ 60 Hz,1.5A Total intended to be used for installation purposes.We Accessory Load:2.5A @ 27.4 VDC power-limited tryto keep our product Standby Current:165mA information up-to Alarm Current:310mA date and accurate.We Battery Charging Capacity:7 to 35AH cannot cover all specific applications or anticipate Battery Size:7AH max.allowed in control panel all requirements.All cabinet.Larger capacity batteries can be housed in specifications are subject RBB accessory cabinet. to change without notice. For Technical Support,call 800-446-6444. Honeywell Silent Knight 12 Clintonville Road Northford,CT 06472 Honeywell 800-328-0103 351607 1 B 1 09/16 1 www_silentknightcom trnnc 2018 Honeywell International Inc KNIG © Err SYS TFJ W SENSORA Indoor Selectable- Output Strobes and Horn Strobes for =_- Ceiling Applications , �A . System Sensor L-Series audible visible notification products are rich with features guaranteed to cut .. installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring, installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING UL �..'? �, 1LISTED �aa S5512 FM approved except 7125-1653 D504 S4011 far ALERT mcde'is 7135-1653 R52 3057383 L-Series Specifications ArchitectflEngineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1 Y2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. PhysicalfElectrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR' Operating Voltage Rangez 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVOS86800 UL Current Draw Data OC Max.Strobe Current Draw tmA RM$) 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 E12 60 30 153 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 5 143 155 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data StrobeHorn and Horn 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVosesaoo L-Series Dimensions 2.47 1.37 6.92 2.50 6.63 e. 0 o o TR M � 0 0 0 0 0 0 o Q o 0 -- Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box 0 �1► /�� twn Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White SCWL-CLR-ALERT Strobe,White,ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White �1 SYSTEM m201 change Sensor Without 3825 Ohio Avenue•St.Charles, IL 60174 Product subject to change without notice Visi[systemsensoccom SEN..SOR• Phone:BOO-SENSOR2•Fax:630-377-6495 or current productinformation,AVDS 6801-03/17stversion [his data sheet AVDSB6001•03/17 ' I SYSTEM SENSOR* eoege'e Indoor Selectable- R e Output Horns, E Strobes, and r Horn Strobes for Wall Applications System Sensor L-Series audible visible notification ,. , products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Plug-in design with minimal intrusion into the back box plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela The L-Series line of wall-mount horns,strobes,and horn strobes • Field-selectable candela settings on wall units: include a variety of features that increase their application versatility 15,30,75,95, 110, 135,and 185 while simplifying installation.All devices feature plug-in designs • Horn rated at 88+dBA at 16 volts with minimal intrusion into the back box,making installations fast • Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,the L-Series utilizes a universal mounting plate for all • Electrically Compatible with legacy SpectrAlert and SpectAlert models with an onboard shorting spring,so installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING OF M �IPI LISTED nvvaovEo 55512 FM approved except 7125-16530504 54011 for ALERT models 7135-1653 G533 3057383.3057072 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/e-inch back box,4 x 4 x 1 Y2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/e-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit""Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110,135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall he a System Sensor Sync-Circuit model MDI 3 listed to I JI 464 and shall hp,approved for fire.protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR'.2 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.01"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.25-D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133mm L x 88mm W x 32mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. _1 -1 UL Current Draw Data StrobeUL Max. 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Law 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 -54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 C1 72j 133 160 185 235 3.1 K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1 K Non-Temporal High 104 131 177 204 230 264 326 3.1 K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data StrobeHorn and Horn 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on the 2-wire horn strobes. L-Series Dimensions .46 - 3.46 3 1.25 — 1.25 — o°o°� °00 ovao 0000000000000 °0°°°0°°°°0 eooeeoo 1 00000 1 0 e 1 0 9 O00°D000OR •''sa!r!��ye. 000000000000, 5.27 5.27 00000:Qoeoa oao�eooeoo°o :0o40o0 ooeecooe to o � e eeo a oeo 0 O r— Compact Strobe/Horn Strobe Compact Hom 4.70 1.91 4.70 1.25 1.25 �I 5.67 .67 o'e444' o'e'e'e44 eeeoe Strobe/Horn Strobe Horn L-Series Ordering Information Model Description Model Wall Horn Strobes Horns P2RL 2-Wire,Horn Strobe,Red HRL Horn,Red P2WL 2-Wire,Horn Strobe,White HWL Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL Compact Horn,Red P2GWL 2-Wire,Compact Horn Strobe,White HGWL Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red, Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBWL Wall Surface Mount Back Box,Red Wall Strobes SBBWL Wall Surface Mount Back Box,White SRL Strobe,Red SBBGRL Compact Wall Surface Mount Back Box,Red SWL Strobe,White SBBGWL Compact Wall Surface Mount Back Box,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking an cover All-ALERT models have"ALERT'marking on cover l STEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2017 System Sensor, Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice Visit systemsensor.com SENSOR y or current product information,including he latest version of this data sheet www.systemsensor.com nvosessos•03m SYSTEM SENSOR` Outdoor Selectable. Output Horns, - -� Strobes, and Horn Strobes for Wall Applications SPECTI�ler't SpectrAlerl®Advance outdoor audible visible products v �► IIN c E are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices, SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40oF to 151IF. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes, and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151 IF Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tarnper-resistant construction damage. Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNAUB6 corrosion.Knock-outs located on the back eliminate the need to drill OC 7300 holes for screw-in mounting.Plastic and metal weatherproof back 3/ ` FM M boxes come with -inch top and bottom conduit entries and 3/4-inch LLO -1653 187(outdoor sVobes) 7125-1653 188 54011(chimes,horn strobes,horns) APPFlOVbe approved (hornnessmoes, knock-outs at the back.A screw-in NPT plug with an O-ring gasket S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:169(horns,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe,and Horn Strobe Specifications ArchitectiEngineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync-Circuit""Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95,110, 115,135, 150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Specifications Temperature -40°F to 151°F(-40oC to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5,6-L x 4.7-W x 2.5-D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7-L x 5.1"W x 2.0-D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max.Strobe Current Draw(rnA RMS) UL Max.Horn Current Draw(rnA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(rnA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15175 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 .187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 Strobe,UL Max.Current Draw(mA RMS),2-Wire Horn 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output candela ratings must be reduced in accordance with 8--175 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. Avos01201 SpectrAlert Advance Diagrams �4.7" 5.6" O 0 Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box l O Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK*f 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor, 120 V(includes plastic wealhetpruol back box) Wall Strobes SRK*t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK*t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add'-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75.95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. SYSTEM ©2012 System Sensor. �� SENS�R� 3825 Ohio Avenue•St.Charles, IL 60174 Product specificationsformactlochangng[teu[nstve syslemsensorcorn Phone:BOO-SENSOR2•Fax:630-377-6495 for wrren[produc[informa on,including lh 3112 latest version of his data sheet AVnS01201•3/12 INTELLIKNIGHT ACCESSORY SILENT SK-Photo, SK-Photo-T KNIGHT and 13S SK-Photon by Honeywell Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector, the SK-Photo-T is a photoelectric smoke detector with thermal and SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description Optional remote LED annunciator (System Sensor@ PN RA100Z) SK-Photo and SK-Photo-T are plug-in Plug-in mounting provides ease of type smoke sensors that combine a installation photoelectric sensing chamber with Tamper-proof feature available on addressable analog communications. Point ID capability allows each mounting bases 4:�7 detector's address to be set with rotary • Listed for use in duct applications address switches, providing exact • Rotary address switches for fast detector locations for selective installation maintenance when chamber • UL Listed contamination reaches unacceptable - FM Approved levels. SK-Photo and SK-Photo-T have a Specifications unique optical sensing chamber that is Physical engineered to sense smoke produced Height: 2.0"(5.0 cm) SK-Photo (Base included) by a wide range of combustion Diameter:4.1"(10.4 cm)installed in sources. In the SK-Photo-T,dual B501 base electronic thermistors add 135°F(57°C) thermal technology to maximize Electrical Compatibility detection. Operating Voltage: 15-32 VDC The SK-Photon is a remote test Standby Current: SK-Photo, and SK-Photo-T are 300 A 24 VDC Maximum compatible with the following detector capable detector for use with the N o� bases: DNR/DNRW duct smoke detector. (not Alarm Current: 6.5 mA @ 24 VDC max B210LP 6"base(included) included) (with LED on) B501 2 wire base Environmental B224RB Relay base Features Operating Temperature B224BI Isolator base SK-Photo: 320—120OF (0°C—49°C) B200SR Sounder base • Sleek, low-profile design SK-Photo-T: 320—100°F(0°C—38°C) The SK-Photo, SK-Photo-T, and SK- • Base included Humidity: 10%—93%non-condensing PhotoR are compatible with the following IntelliKnight FACPs: • Reliable analog communications for Other Ratings 5820XL trouble-free operation SK-Photo-T Thermal: Fixed 5820XL-EVS • Age resistant polymer housing temperature set point 135°F(57°C) 5808 • Dual electronic thermistor design on Velocity: 0—4000 fpm (0—20 m/sec) 5700 the SK-Photo-T Installation 5600(Rev 2.0 or higher) • Superior EMI resistance for reliability • Simple field cleaning for code The SK-Photo and SK-Photo-T plug compliance into a compatible IntelliKnight-series • Variety of mounting options to meet detector base.The SK-PhotoR is a any application remote test capable detector head • Dual LED indicators for 3600 visibility included within the DNR(W)duct smoke detector. P/N 350118 Rev F • Detector transmits signal to indicate @ 2016 Honeywell International Inc. maintenance is required ACCESSORY Model SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B21OLP (included). The PhotoR is a remote test capable detector for use with DNR(W) duct smoke detectors. (not included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. SLC IN OUT Compatible FACP L ! RA100Z(Optional) + Ii ....................... { i I i i 3 z 3 ? 3 2 f I i I ...................«..................................................................................................«........................................................ .................................j ..........»....»........... «..»». ... . .............................Class A Option..Wiring ....«_«.« « «.««.« ... ».... ». ... «....««.......«........................................ 1 Wiring SKSeries Detector Mounting Bases SILENT This document is not intended to be used for installation purposes. We try to keep our KNIGHT product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more s information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: by Honeywell (800)328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444.www.silentknight.com INTELLIKNIGHT ACCESSORY SILENT SK-Pull-SA and SK-Pull-DA KNIGHT Intelligent Pull Stations by Honeywell The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description -_ The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight PULL OWN Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition • Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red SK-Pull-SA in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility PUSH IN Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Meets ADA requirement for 5 Ibs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® • Reliable analog communications for trouble-free operation SK-Pull-DA • Braille text on station handle Compatibility • Handle latches in down position and the word Activated The SK-Pull-SA and SK-Pull-DA are compatible appears, clearly indicating the station has been pulled with the following IntelliKnight FACP's: 5600 • Rotary address switches for fast installation 5700 5808 • UL Listed, including UL 38, Standard of Manually Actuated 5820XL Signaling System 5820XL-EVS P/N 350135 Rev D ©2016 Honeywell International Inc. ACCESSORYINTELLIKNIGHT 4 Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans,Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. 777;�t..,.................._......_......... ............................ P................................................_.- ..-.................... IN .;—. —..___—«—.Y_.W.....—.—_......................... ..._....._.._........_..... t 5LC OUT cu�x a commmliimb FRCP e 5 ion q • ! ! It t 1 t L t Class B Ifftnp: Wiring SK-Pull-SA&SK-Pull-DA Pull Stations Specifications Electrical Physical Operating Voltage: 15-32 VDC Height: 5.5"(14 cm) Average Operating Current(LED flashing): 300 pA Width:4"(10.2 cm) Wire Gauge: Up to 12 AWG(3.1 mm2) Depth: 1.45"(3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 32"—120OF (0°C—49°C) Bi-Colored LED: Humidity: 10%—93% non-condensing Blinking Green: Normal Steady Red:Alarm Accessories Switch: Single pole, single throw(SPST) normally open (N/O) BG-TR Optional trim ring. switch which closes upon activation of the pull station SB-1/0 Surface backbox SILENT' This document is not intended to be used for installation purposes.We try to keep our product G information up-to-date and accurate.We cannot cover all specific applications or anticipate all Iff requirements.All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800)328-0103, by Honeywell Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com O. 3 SILENT SK-Heat, SK-Heat-HT KNIGHT and °by Honeywell SK-Heat-ROR Addressable Thermal Heat and Rate-of-Rise Detectors The SK-Heat, SK-Heat-HT, and SK-Heat-ROR are plug in thermal detectors, with integral communication, that provide features that surpass conventional detectors. These thermal detectors are for use with Silent Knight IntelliKnight series Fire Alarm Control Panels (FACPs). IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Description • Detector transmits signal to SK-Heat, SK-Heat-HT and SK- indicate maintenance is required Heat-ROR are intelligent sensors • Plug-in mounting provides ease that utilize a state-of-the art of installation thermistor sensing circuit for fast • Optional remote LED annunciator response. Sensitivity is (System Sensor®PN RA100Z) continuously monitored and reported to the FACP. Point ID • Tamper-proof feature available on capability allows each detector's mounting bases address to be set with rotary • Rotary address switches for fast address switches, providing exact installation SK-Heat(base included) detector locations for selective • UL Listed SK-Heat-ROR: Rate-of-rise maintenance when chamber detection 15°F/min 8.3°C/min contamination reaches Specifications ( ) unacceptable levels. Physical Compatibility SK-Heat is a fixed temperature Height: 2.0" (51 mm) P The SK-Heat, SK-Heat-HT and SK- sensor that uses a thermistor Diameter: 6.1" (155 mm) installed in B210LP base Heat-ROR are compatible with the sensing circuit to produce 1351 F following detector bases: (57°C)fixed temperature alarm. Shipping Weight: 4.8 oz (137 g) Electrical B210LP 6" base (included) SK-Heat-HT is a variable high B501 2 wire base temperature detector that provides Operating Voltage: P P 15 to 32 Volts DC Peak B224B1 Isolator base high temperature detection at B224RB Relay base 135°F - 190°F. (57°C - 88°C) Standby Current: B200SR Sounder base SK-Heat-ROR is a rate-of-rise 300taA @ 24 VDC The SK-Heat-HT and SK-Heat- temperature sensor with 135°F LED Current: 6.5 mA@ 24 VDC ROR are compatible with the (57°C)fixed temperature alarm. Environmental following IntelliKnight FACP's: Features Operating Temperature 5820XL • Reliable analog communications SK°-Heat & SK-Heat-ROR: 5820XL-EVS for trouble-free operation -4 — 1 00 F (-20 C—38 C) 5808 P 5700 • Age resistant polymer housing SK-Heat-HT: -4°— 150°F (-20°C—66°C) The SK-Heat is compatible with the • Innovative thermistor sensing following IntelliKnight FACP's: circuit Humidity: 10% —93% • Superior EMI resistance for noncondensing 5820XL reliability Thermal Ratings 5820XL-EVS SK-Heat: Fixed temperature alarm 5808 • Variety of mounting options to 5700 meet any application 135°F (57°C) 5600 (Rev 2.0 or higher) • Dual LED indicators for 3601 SK-Heat-HT: High temperature heat visibility sensor 135°F - 190°F (57°C -88°C) P/N 350120 Rev. F ©2016 Honeywell International Inc. INTELLIKNIGHT O. Model SK-Heat, SK-Heat-HT, SK-Heat ROR Addressable Thermal and Rate-of-Rise Thermal Detectors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent Thermal Sensor Silent Knight Model SK-Heat, SK-Heat-HT or SK-Heat-ROR. The base included shall be 132101-P. The Heat detector shall have a flashing status LED for visual supervision. When the detector is activated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required.Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. i Sic IN OUT i Compatible FACP �— 3 RA10OZ(Optional) + i3 J ....................... i 1 1 1 : 3 2 3 2 3 2 : 1 i i t :...........................................................................................................................................................w.............. / .................................a S Class A Optional Wiring i...............................................................................................................................-..................................................... / .....-........................»................................. Wiring SK-Series Detector Mounting Bases Accessories M02-09-00-Test Magnet with Telescoping Handle RA100Z-Remote LED Annunciator. XP-4-Extension Pole for XR2B. Extends from 5—15 ft. RMK400-Recessed Mounting Kit. Provides low profile for use with T55-127-000-Detector Removal Head B501 XR213-Detector Removal Tool A removal and re-placement tool for BCK-200B-Black Detector Kit For SK-series detectors SK plug-in detectors. Includes the T55-127-000 "Unless otherwise noted,specifications apply to all SK thermal M02-04-01 -Replacement Test Magnet. detectors. SILENT This document is not intended to be used for installation purposes We try to keep our product information up-to- date and accurate.We cannot cover all specific applications or anticipate all requirements All specifications are 01 KNIGHT subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road Northford,CT 06472-1610 Phone-(800)328-0103, Fax:(203)484-7118 For Technical Support,Please call 800.446.6444. by Honeywell www.slientknight.com INTELLIKNIGHT ACCESSORY SILENT SK-Beam KNIGHT and SK-Beam-T by Honeywell Single-ended Reflected Type Projected Beam Smoke Detectors The SK-Beam and SK-Beam-T are uniquely suited for protecting open areas with high ceilings where other methods of smoke detection are difficult to install and maintain. Now there's even more power and flexibility available to the IntelliKnight family of products! For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Beam and SK-Beam-T are addressable beam smoke detectors for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK-Beam-T also includes an integrated sensitivity test feature. i Installation of the single-ended reflective design is much easier / than dual ended projected beam detectors.Alignment is quickly / accomplished using an optical sight and a two-digit signal strength ' meter incorporated into the SK-Beam and SK-Beam-T. Listed for operation from-22°F to 131°F(-30°C to 551C),the SK- Beam and SK-Beam-T can be used in applications to provide early SK-Beam and SK-Beam-T warning in environments where temperature extremes exceed the • Optional integral NFPA 72 sensitivity test capability of other types of smoke detectors. feature The SK-Beam and SK-Beam-T consist of transmitter/receiver unit • Removable plug-in terminal blocks and one reflector. When smoke enters the area between the unit • Digital display for easy alignment and the reflector it causes a reduction in the signal.When the . Built-in automatic gain control compensates smoke level reaches the predetermined threshold,the detector for signal deterioration from dust build-up generates an alarm signal. g p These beam smoke detectors have four sensitivity selections • Rotary address switches for fast installation along with two Acclimate settings. When either of the two • Paintable cover Acclimate settings are selected,the detector will automatically Installation adjust its sensitivity using advanced software algorithms to select the optimum sensitivity for the specific environment. The SK-Beam and SK-Beam-T transceiver/receiver The SK-Beam-T is equipped with an integral sensitivity test feature can be mounted over a recessed junction box or that consists of a test filter attached to a servo motor inside the surface mounted using the System Sensor surface detector optics. Using the remote test station, System Sensor®PN mounting kit BEAMSMK.The reflector is surface RTS151,the motor is activated and moves the filter in the pathway mounted. For applications in which the reflector of the light beam,which tests the detector sensitivity.This integral cannot be placed at the necessary angle,the multi- sensitivity test feature allows the user to quickly and easily meet mounting kit is required System Sensor PN the annual maintenance and maintenance and test requirements BEAMMMK. of NFPA 72. Compatibility Features The SK-Beam and SK-Beam-T are compatible • 16 to 328 foot protection range with the following IntelliKnight FACP's: 00 • Single-ended, reflective design 5 570 • Remote test station available 5820XL • User friendly alignment procedure 5820XL-EVS • Six user selectable sensitivity levels P/N 350123 Rev D ©2016 Honeywell International Inc. INTELLIKNIGHT ACCESSORY Model SK-Beam and SK-Beam-T Beam Smoke Detectors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Single-ended Reflected Type Projected Beam Detector Silent Knight model SK-Beam or SK-Beam-T. The long range projected beam smoke detector is designed to provide open area protection. . The detector shall consists of a transmitter/receiver unit and a reflector. Three LEDs on the detector indicate the current status: a red LED for alarm, a yellow LED for trouble, and a blinking green LED for standby operation Specifications Electrical Operating Operating Voltage: 15—32 VDC Protection Range: 16'—328' (5— 100 m) Standby Current (Avg): 2 mA max Adjustment Angle: +/-10*horizontal &vertical (optics move Current During Testing (Avg): 500 mA max independent of the unit) Alarm Current: 8.5 mA max Fault Current: 4.5 mA max Sensitivity Levels: Level 1-25%; Level 2-30%; Level Alignment Mode Current: 20 mA 3-40%; Level 4-50%; Level 5-30 to 50% (Acclimate) Level 6-40 to 50%(Acclimate) Accessories Fault Condition (Trouble): 96% or more obscuration BEAMLRK Long Range Accessory Kit. Required blockage in alignment mode; improper alignment; self- for applications in excess of 230 compensation limit reached ft(70m). Alignment Aid: Optical gun sight; integral signal strength BEAMMMK Multi-Mount Kit. Provides ceiling or indication; 2-digit display wall mount capability with increased angular adjustment LEDs: Normal—flashing green; Yellow—trouble; Red—alarm for either the beam or the reflector. Test/Rest Feature: Integral sensitivity test filter(SK-Beam-T When installed with the only); sensitivity filter(incremental scale on reflector); local transmitter/receiver unit, BEAMSMK test switch; local reset switch; remote test and reset switch must also be used. (compatible with RTS151 and RTS151 KEY test station) BEAMSMK Surface Mount Kit Physical RTS151 Remote Test Station. Used to initiate Detector: 10"H x 7.5"W x 3.3" D the NFPA sensitivity test function. (25.4cm x 19.1cm x 8.4cm) RTS151KEY Remote Test Station with Key Lock Reflector for 16'—230': 7.9"H x 9.1"W (20cm x 23cm) BEAMHK Heater Kit for Transmitter/Receiver Reflector for Beyond 230': 15.7"H x 18.1"W(40cm x 46cm) Unit. See electrical requirements in Shipping Weight: 3.9 Ibs(1.77 kg) the Specifications. Environmental BEAMHKR Heater Kit for Reflector. See electrical Operating Temperature: -22°F— 131IF (-30°C— 55°C) section. requirements in the Specifications Humidity: 10% —93% non-condensing SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all KNIGHT requirements.All specifications are subject to change without notice. For more information, contact „z Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800)328-0103, by Honeywell Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM INSPECTION AND TESTING FORM To be completed by the system inspector or tester at the time of the inspection or test. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Date of this inspection or test: Time of inspection or test: 1. PROPERTY INFORMATION Name of property: y ?p°AI1- (fC)mno�... 0-&Uir'C k Address: (..)7 �,( 5.�,)�,� pi a/v ) Description of property:CJVVWL_ Occupancy type:C.CT&"1-C i-fl( Name of property representative: M A Address: 5A 0—"- Phone: CC(;a5� 7�0'%U-3N Fax: E-mail: Authority having jurisdiction over this property: 1%c 1,�,y�I.J Phone: Fax: E-mail: 2. INSTALLATION, SERVICE,AND TESTING CONTRACTOR INFORMATION Service and/or testing orgaiiization for this equipment: <3.CXS Acldress:�O j j� 3SS`�' Ac- (0,1 t�Cy.l� Le<Ad �� Phone oS1...l68-1 Fax. E-mail: LX lc(Cj P C�C,f/,,,q(c Sccen �t�,� ILa'rd' Service technician or tester-j.n'p Qualifications of technician or tester: �CCXe���ft2t A contract for test and inspection in accordance with NFPA standards is in effect as of: The contract expires: AIIy.. Contract number: Ar Frequency of tests and inspections:/fa,p., J'K Monitoring organization for this equipment: 6SC�3 Address:"'16 (� T5,ill;9 I,-It V--�t-"u,'n IY .193 Phone: cwS�-Io'Y 3 Fax: E-mail: (/r���fKj O( �t'�`J'e¢�n4 (. CC/_L Entity to which alarms are retransmitted: Phone: 3. TYPE OF SYSTEM OR SERVICE Ispire alarm system(nonvoice) ❑Fire alarm with in-building fire emergency voice alarm communication system(EVACS) ❑Mass notification system(MNS) ❑Combination system,with the following components: ❑Fire alarm ❑ EVACS ❑MNS ❑Two-way, in-building,emergency communication system ❑Other(specify): Copyright O 2009 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution, $u�ls,Qqo� r 3. TYPE OF SYSTEM OR SERVICE (continued) NFPA 7_2 edition: Additional description of system(s): 3.1 Control Unit 9 Manufacturer: Se(�..t f ��� Model number:11-7100 3.2 Mass Notification System (This system does not incorporate an MNS. 3.2.1 System Type: ❑In-building MNS—combination ❑In-building MNS—stand-alone ❑Wide-area MNS ❑Distributed recipient MNS ❑Other(specify): 3.2.2 System Features: ❑Combination fire alann/MNS ❑MNS ACU only ❑Wide-area MNS to regional national aletting interface ❑Local operating console(LOC) ❑Direct recipient MNS(DRMNS) ❑Wide-area MNS to DRMNS interface ❑Wide-area MNS to high-power speaker array(HPSA)interface ❑In-building MNS to wide-area MNS interface ❑Other(specify): 3.3 System Documentation owner's manual,a copy of the manufacturer's instructions,a written sequence of operation,and a copy of the record record drawings are stored on site. Location: F 3.4 System Software is system does not have alterable site-specific software. Software revision number: Software last updated on: ❑A copy of the site-specific software is stored on site. Location: 4. SYSTEM POWER 4.1 Control Unit I a(7 JM 4.1.1 Primary Power /96 UAC Input voltage of control panel: 1 ao LJ G1` Control panel amps: 4.1.2 Engine-Driven Generator $this system does not have a generator. Location of generator: Location of fuel storage: Type of fuel: 4.1.3 Uninterruptible Power System his system does not have a UPS. Equipment powered by a UPS system: l Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode(hours): In alarm mode(minutes): Copyright©2009 National Fire Protection Association,This form may be copied For individual use other than For resale.It may not be copied for commercial sale or distribution. 4. SYSTEM POWER(continued) 4.1.4 Batteries �1 Location: Type: 15L/ Nominal voltage: 10, Amp/hour rating: —7 Calculated capacity of batteries to drive the system: In standby mode(hours): r3V ( In alarm mode(minutes): Batteries are marked with date of manufacture. 4.2 In-Building Fire Emergency Voice Alarm Communication System or Mass Notification System ?61is system does not have an EVACS or MNS. 4.2.1 Primary Power Input voltage of EVACS or MNS panel: EVACS or MNS panel amps: 4.2.2 Engine-Driven Generator This system does not have a generator. Location of generator: (� Location of fuel storage: Type of fuel: 4.2.3 Uninterruptible Power System ckhis system does not have a UPS. Equipment powered by a UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode(hours): In alarm mode(minutes): 4.2.4 Batteries Location: FC Type: Nominal voltage: 1 Amp/hour rating: Calculated capacity of batteries to drive the system: In standby mode(hours): a� In alann mode(minutes): ❑ Batteries are marked with date of manufacture. 4.3 Notification Appliance Power Extender Panels his system does not have power extender panels. 4.3.1 Primary Power Input voltage of power extender panel(s): Power extender panel amps: 4.3.2 Engine-Driven Generator is system does not have a generator. Location of generator: Location of fuel storage: Type of fuel: 4.3.3 Uninterruptible Power System system does not have a UPS. Equipment powered by a UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode(hours): In alarm mode(minutes): Copyright 0 2009 National Fire Protection Association This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. 4. SYSTEM POWER(continued) 4.3.4 Batteries Location: C aC rn Type: �L Nominal voltage: �� Amp/hour rating: Calculated capacity of batteries to drive the system: In standby mode(hours): aL( In alarm mode(minutes): 7 Batteries are marked with date of manufacture. 5. ANNUNCIATORSThis system does not have annunciators. 5.1 Location and Description of Annunciators Annunciator 1: Annunciator 2: Annunciator 3: 6. NOTIFICATIONS MADE PRIOR TO TESTING Monitoring organization Contact: Time: Building management Contact: Time: Building occupants Contact: Time: Authority having jurisdiction Contact:�� Time: Other,if required Contact: Time: 7. TESTING RESULTS 7.1 Control Unit and Related Equipment Visual Functional Description Ins ection Test Comments Control unit ❑ Lam s/LEDs1LCDs ❑ TV Fuses 0 ❑ Trouble signals ❑ Disconnect switches ❑ I Ground-fault monitoring ❑ Supervision ❑ Local annunciator ❑ Remote annunciators ❑ ❑ rI Power extender panels ❑ ❑ ?J Isolation modules ❑ ❑ Iw�� Other(specify) ❑ ❑ Copyright©2009 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. 7. TESTING RESULTS (continued) 7.2 Control Unit Power Supplies Visual Functional Description __Inspection Test Comments 120-volt power ❑ Generator or UPS ❑ ❑ Iv hN— Battery condition ❑ pj tel— Load volla c ❑Discharge test ❑ Charger test ❑ Other(specify) ❑ ❑ 7.3 In-Building Fire Emergency Voice Alarm Communications Equipment Visual Functional _T_Description _ Ins ection Test Comments Control unit ❑ ❑ Lamps/LEDs/1-CDs ❑ ❑ Fuses ❑ ❑ Prima ower supply ❑ ❑ Secondary ower supply ❑ ❑ Trouble signals ❑ ❑ Disconnect switches ❑ ❑ Ground-fault monitoring ❑ ❑ Panel supervision ❑ ❑ System perforniance ❑ ❑ Sound pressure levels ❑ ❑ Occupied ❑Yes ❑No Ambient dBA Alarm dBA (attach report with locations,values, and weather conditions) System intelligibility ❑ ❑ ❑CSI ❑STI (attach report with locations,values, and weather conditions) Other(specify) ❑ ❑ Copyright®2009 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. r 7. TESTING RESULTS (continued) 7.4 Notification Appliance Power Extender Panels Visual Functional Description Inspection Test Comments Lam s/LEDs/LCDs ❑ ❑ Fuses ❑ ❑ Primary power supply ❑ ❑ Secondary power supply ❑ ❑ Trouble signals ❑ ❑ Ground-fault monitoring ❑ ❑ Panel supervision ❑ ❑ Other(specify) ❑ ❑ 7.5 Mass Notification Equipment Visual Functional Description Inspection Test Comments Functional test ❑ ❑ 1Reset/po%ver down test ❑ ❑ Fuses ❑ ❑ Primary power supply ❑ ❑ UPS power test ❑ ❑ Trouble signals ❑ ❑ Disconnect switches ❑ ❑ Ground-fault monitoring ❑ ❑ CCU security mechanism ❑ ❑ Prerecorded messy a content ❑ ❑ Prerecorded message activation ❑ ❑ Software backup performed ❑ ❑ Test backup software ❑ ❑ Fire alann to MNS interface ❑ ❑ MNS to fire alann interface ❑ ❑ In-building MNS to wide-area ❑ ❑ MNS Copyright©2009 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. c+ 7. TESTING RESULTS (continued) 7.5 Mass Notification Equipment(continuer/) Visual Functional Description Inspection Test Comments MNS to direct rcei ient MNS ❑ ❑ Sound pressure levels ❑ ❑ Occupied ❑Yes ❑No Ambient dBA Alarm dBA (attach report with locations,values, and weather conditions System intelligibility ❑ [ ❑CSI ❑STI (attach report with locations,values, and weather conditions) Othcr(spccil'y) ❑ ❑ 7.6 Two-Way Communications Equipment Visual Functional Description Inspection Test Comments Phone handsets ❑ ❑ Phone'acks ❑ ❑ Off-hook indicator ❑ ❑ Call-in signal ❑ ❑ System performance ❑ ❑ System audibility ❑ ❑ System intelligibility ❑ ❑ Radio communications ❑ ❑ enhancements stem Area of refuge communication ❑ ❑ -system Elevator emergency ❑ ❑ communications system Other(specify) ❑ ❑ Copyright 9 2009 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. 7. TESTING RESULTS (continued) 7.7 Combination Systems Visual Functional Descri tlon Inspection Test Comments Fire extinguishing monitoring ❑ ❑ devices/system Carbon monoxide detector/system ❑ ❑ Combination fire/security system ❑ ❑ Other(specify) ❑ ❑ 7.8 Special Hazard Systems Visual Functional Description(specif}) Inspection Test Comments ❑ ❑ ❑ ❑ ❑ ❑ 7.9 Emergency Communications System ❑ Visual ❑ Functional ❑ Simulated operation ❑ Ensure predischarge notification appliances of special hazard systems are not overridden by the MNS. See NFPA 72,24.4.1.7.L 7.10 Monitored Systems Visual Functional Description(specify) Inspection Test C mments Engine-driven generator ❑ ❑ Fire pump ❑ Special suppression systems ❑ ❑ Other(specify) ❑ ❑ Copydght©2009 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. 95'-0" 62'-6" 25'-3/4" I o a F.1 c� IL n T OID O an �� ._.emu .......r � a sr / a / / /If Z / / N / / j � 1 a• �i a I f+ c / s A 1 '- � 3 v W D 2 2 � � G \ \ O 1\ \ \.io \ \\ \ a 1 N \ � 1 j0f` I r I i I F 1 1 ' i am M 1 tn LU Ln A 1 w • • ' Oowo N O Ln Ls aM o T O m • y m M o. o- c = N t0 3 li V C co Z Ll 30 m 0 b T 3 m r (A 2 .� D O �� W 0 < � cnD Z �M Mo 0 0 3 (A0C O z = cn ; 3 D m-1 m D r 3 M. O �N 0 O D m p �mv z y TJ coT W y O ~ y T N •• 2 ` I i �-. cr I I + � L _r � _ m to e E cr % m o � = to cr § ! i / - � Ln » § I § � f 11 L / » � Ln Ln § » tA 7� tA Ln E � a z _ Lrl . @ �| ■ | - - - • � t� | � E | ' .0 X3 | 9 Eƒ � � c =a E ' Ear § � ƒ giJ � f E >n M, & Z, � ■ . ' R 00Z'�t | � em . c ogtg o- � > @ §�/ | ) 0 / m 2 � 2 0 00 \ . ƒ ƒ - . 13 0 » \ g § L Q | 3 CL W 3 ul z 2 � ) Ln 3 / k E _ � k to 9 � - , A F, �c t'�pC! �$`, S1l7�S p"L'f¢�Ql� q 'T 7E}q S¢�! PA /h g t► i a�S��n n 5y gN g lg�+ d �yTy�, [� a O O A} O O y x i 4 % 3 A `f y 8 S l i T T TX b < " B R E S v s lY 0 s o� _ ♦' o p o p o o PPR 0 0 0 0 0 o e... �$$ Npp ppppoo po peppeooa oo pp a oop Lj 3 D J b n nt Ou Z o m ® cnD �' o � zyz z G7 0 m G� X(1) © T� ° > 0 -a "0 rn > ITi u S h-� c) IT) o m -j -< O -r m n-i C7 ni z �-� C L r %T tIA .fir l ' 0 Z C Z C ry in (n cn cn cn Z Z Ul En U) vi Z Z ur Ez n sh n m o 3 3 3 3 3 w n� 3 3 3 3 °` a CD 0 0 0 0 0 0 o Q o o 0 0 0 0 n n 0 0 0 Cl ° rrr � � rpo r� n c (n En aaoo aso �' Ncr m m ma`iv2i � m ° N a a N a a" a a w g a m m tl N N N IL N cn N 00000 � 1g9g $ 0000EIg c o p o o o o �j o o o o o o 'o 0 (C0�� pp0� 00p m0 0 407 80 N0 0 Uo� o n V V Cal j N vua , ° 1,► J tA +. N r' 04 Li vi J F, ILI IP- J C�•1 In _ � i 1 M ON PON i l £ R N IS � I i 9 d m a�-° N a m °' pp RE cr A v Q = w o a EI _ aim ; oM mN�m ® � gin£.—gym 6 n 5 m m m m o °i m m N S v FF 7 W 'ram N+2 Ong NNg �N O -IS C'^ 'aN nr maO.gf ro 002 S 07m S� t dyQ � i� gdr - g ^ J.'yi7S�a A r� Pdp6Qin0 an a HIM iv Q �+ ' p� �a4 €���� ��a 'eat� � �gmm �� Q�"gym goll ^ A t R •`8 S fi m m m j g - x Q�jj ny ash a � m m� M- =aU i -68 gMWklgA m o_ a9�8 1 1 is 3ga a� � Q a 9aba � ƒHIM { A . � kl , / B ;& � � . , - -_ ,-a- � - © E ez§ | ■ f/ � � ! `| . | § rL ■;§ � ■a■§■ • - ' o e§§ G§§§§| + |+4||E ■ � �■� e �-��E\ ' � s=■ � !■-®2 e§m�as® I ,��a�m;lR|! §§§ §a■a■| ; ■&■§ §§§§| eeaa 'aea[ e■,■�ee■R|� � §ma ■am§ 2 mlmm§!■!2 e■�■�@s;� 2§; § mm22§ m§§ ■ m§m@2 m)mmm§&2} ) 7T � a = gq op � g ! o� m 69 V1 inn iS O ' 0 0 o S A d . rat, i 75 15 115 15 15 15 NAC2#W H H H S S S A BICIDIElFIGIH111 ,1111 K I L 30 30 115 15 30 c o J . NAC1#14/2 H H H S S 1 2 Manu al Pull Station Activation it x X 3 Smoke DetectorActruation XI x I I I X SLCri1s/2 F S H H F S S 4 Oven,Circuit x x 5 Ground Fault x x b Notification Appliance Circcuit Short X x S S S 7 Fire Alarm AC Power Fairure x x S F B F 8 Fre Alarm Low Battery x x F S S S S H H Operational Matrix F 110vac FAP 4-#14 THHN to main building AES radio. ALM/TBL NOTES a All wiring is FPLR FD Pull Station a Ceiling heights are 8' throughout, except the $O Smoke Detector auditorium which is 14'. ® Mount pull stations 42" to 48" AFF OHeat Detector e Connect alarm and trouble output to spare AES zones BB] Beam Smoke Detector (existing). Place EOL devices at FACP for supervision of the interconnect. Horn-Strobe O—1 Strobe • Smokey Point Community Chruch 17721 Smokey Point Blvd., Marysville, 98271 Fire Alarm System SIZE DATE DRAWN BY REV 29-MAY-2019 T Brown NICET ID 144003 1 800-�_.J-SAFE SCALE 3/32"=1'-0" RIB. and LEGEND SHEET 2 OF 2 Date: 03/27/2026 Permit#: 2699 Permit 08/01/2019 Date: Review 08/01/2019 Date: Permit FIRE ALARM Type: Review FIRE ALARM Type: Target Date: 08/15/2019 Scheduled 00:00 Time: Completed 09/05/2019 Date: Description: 1. Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request. 2. Battery load test required, switch system to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for initiation, notification and signaling circuits. 4. Furnish a written statement to the Arlington Fire Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection (NFPA 72 Section 7.5.2). 5. The record of completion form shall be submitted prior to project close-out. Review Status: Assigned To: FIRE Time In: 00:00 Time Out: 00:00 Hours: 1.0 Property Information Parcel#: 31052100301800 CHRISTIAN&MISSIONARY ALLIANCE- ARLINGTON CHRISTIAN & MISSIONARY ALLIANCE- 17721 SMOKEY POINT BLVD ARLINGTON 17721 35TH AVE NE ARLINGTON, WA 98223 Zoning: 699 Other Miscellaneous Services NECLot: Block: Permit#: 2699 Permit Date: 08/01/19 Permit Type: FIRE ALARM Project Name: Smokey Point Community Church Fire Alarm Applicant Name: Olympic Security& Communication Applicant Address: PO Box 3559 Applicant, City, State, Zip: Arlington,WA 98223 Contact: Vikki Ryason Phone: 360-652-1088 Email: vkki@olympicsecurity.com; tom@olympicsecurity.com Scope of Work: Install AES Radio Valuation: 4500.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Opportunity Zone Permit Issued: 09/18/2019 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning CHRISTIAN& MISSIONARY 699 Other 31052100301800 17721 35TH AVE NE ALLIANCE- Miscellaneous ARLINGTON Services NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License# OLYMPIC SECURITY 360-652-1088 PO BOX 3559 CONSTRUCTION Labor& OLYMPSC012QP CONTRACTOR Industries Plan Reviews Date Review Type Description Assigned To Review Status 08/01/2019 FIRE ALARM BUILDING 1.Permit and set of approved plans to remain on site during installation.Installers shall present NICET II certification upon request. 2.Battery load test required,switch system to battery operation 24-hours prior to final inspection.Notification appliances to operate for 5 minutes on battery power. 3.Trouble condition to be verified for initiation, notification and signaling circuits. 08/01/2019 FIRE ALARM 4.Furnish a written statement to the Arlington Fire FIRE Department stating that the system has been installed in accordance with the approved plans and tested in accordance with the manufacturer's published instructions and appropriate NFPA requirements prior to scheduling an inspection(NFPA 72 Section 7.5.2). 5.The record of completion form shall be submitted prior to project close-out. Fees Fee Description Notes Amount Fire Alarm Plan Review Fee $100.00 Fire Sprinkler System Commercial NFPA 13/13R $162.56 Processing/Technology $25.00 Credit Card Service $8.63 Total $296.19 Attached Letters Date Letter Description 09/17/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 09/17/2019 VIKKI RYASON 77084542 $287.56 09/17/2019 77084542 CC Surcharge Raelynn Jones $8.63 Outstanding Balance $0.00 Notes Date Note Created By: 08/01/2019 Applicant indicated that the submitted plans are to scale. Raelynn Jones Uploaded Files Date File Name 09/23/2021 9752945-2699 IC 1.31.2020 Final.pdf 01/14/2020 6103400-2699 Inspection&Testing Form.pdf 01/14/2020 6103398-2699 1-13-2020 IC.pdf 09/18/2019 5626796-2699 Issued Permit.pdf 09/18/2019 5626697-2699 Issued Permit.pdf 09/05/2019 5557579-Smokey Point Community Church Fire Alarm Plan Review(Revision).pdf 08/01/2019 5401336-2699 Application.pdf