Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
213 Lenore Ave_BLD2693_2026
CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA, 98223 PHONE; (360)403-3551 BUILDING P.ERNUT Address:213 N.Lenore Ave Permit#:2693 Parcel N:00455400200700 Valuation:0,00 OWNER APPLICANT CONTRACTOR Name:MUFFLY P.AUL W JR/BELAN ALISSA I Name:Parker Bros Heating Name:Parker Bros Heating Address:213 N DUNHAM Address:13630 54th Dr NE Address:13630 54th Dr NE City,State Zip:ARLINGTON,WA 98223 City,State Zip:Marysville City,State Zip:Marysville,WA 98271 Phone; Phone:360-572-0108 Phone:360-572-0108 LIC:PARKEBR823JF EXP:04/06/2020 MECHANICAL CONTRACTOR PLUNMWG CONTRACTOR Name:Parker Bros Heating Name: Address: 13630 54th Dr NE Address: City,State,Zip:Marysville,W.A.98271 City,State,Zip: Phone:360-572-Qt08 Phone: LIC#;PARKEBH823JF EXP: 04/06/2020 LIC#: EXP: JOB DESCREM, ON PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY. NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF TIME STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RC W 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1t0/IRCI10_ SALES TAX V Sale tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return fonn an c ed "iry Ar in t n#3101. W111am � � � � h � ?� 7/30/2019 Signature Print Name Date elcased Date CONDITIONS 3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated; use of adhesive tapes are prohibited. Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. _ ]P]C T, FLES Date Description Fee Amount 7!3012019 Heat Pump $75,00 7/30/2019 Mechanical Permit Base Fee $25,00 7!30/2019 Processing/Technology Fee $25.00 Total Due: $125.00 Total Payment: $0.00 Balance Due: $125.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon i .. �� r' Permit Information Date 7/30/2019 Permit Number 2693 Project Name Muffly Applicant Name Parker Bros Heating Applicant Address 13630 54th Dr NE City,State,Zip Marysville Contact Phone 360-572-0108 Email admin@parkerbroselectric.com Permit Type Residential Mechanical Site Address 213 N.Lenore Ave Valuation 0.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Residential Mechanical Number of Stories 0 Proposed Use Install heat pump/1 outdoor unit and 2 indoor head units MIC/Opportunity Zone Assigned To Raelynn Jones Property Parcel Address Legal Owner Owner Phone Zoning 00455400200700 1213 LENORE AVE I IMUFFLY PAUL W JR/BELAN ALISSA J 111 Single Family Residence-Detached Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# Parker Bros Heating 360-572-0108 dmin@parkerbroselectric.com ICONTRACTOR -&I IPARKEBH823JF Fees Fee Description Notes Amount Heat Pump 322.10.00.00 3 CED$25 ea. $75.00 Mechanical Permit Base Fee 322.10.00.00 $25.00 Processing/Technology Fee 341.43.00.02 $25.00 Total $125.00 Uploaded Files ad File Date File Uploaded By 1 7/30/2019 1:08:30 PM 12693 Application pdf liones, Raelynn I x i� �i i ' , °F RESIDENTIAL MECHANICAL ® PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:213 N Lenore Ave Project Description:Install Heat Pump - 1 Outdoor Unit & 2 Indoor Head Units Owner: Paul Muffly Address: 213 N Lenore Ave City: Arlington StateWA Zip Code: 98223 Phone: 425-501-2748 Email:paul_muffly@hotmail.com Applicant: Parker Bros Heating - Natalie Poma Address: 13630 54th Dr NE City: Marysville State WA Zip Code: 98271 Phone: 360-572-0108 Email: natalie@parkerbroselectric.com CONTRACTOR INFORMATION Contractor Name:Parker Bros Heating Address: 13630 54th Dr NE City: Marysville StateW. A Zip Code: 98271 License Number:PARKEBH823JF Expiration: 04/06/2020 Phone:360-572-0108 Email:admin@parkerbrosheating.com Z� Received STAFF USE ON L 'JUL 2 9 2019 Permit #: b 2iQC13 Accepted by: Date: 6/16LP Page 1 of 2 r L I _ � I R -� ~ i. � �_�. � RESIDENTIAL MECHANICAL e " e PERMIT APPLICATION Department of Community& Economic Development City of Arlington •18204 59th Ave NE• Arlington,WA 98223• Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES Furnace(80+) Model# AFUE_ Heat Pump Model#MHP MUZD30NA-1 AFUE HSPEB.2 I{ AC Unit Model # SEER 14.5 Freestanding Stove ❑ Fire Place Insert U Outdoor BBO ❑ Gas Piping Solid-Fuel Appliance Other _. IF Gas Piping Informational Not Applicable: I� Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of ali Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature:__. """~ _ Dates Applicant Printed Name: _}�I }Ld fn I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 .:• I [-Ionic Espahol Contact Search L&ISEARCH UlLa'bo'r s Industries Workplace Rights .• - • AWashington State Department of Labor & Industries PARKER BR©S HEATING LLC Owner or tradesperson 13630 54TH DR NE Principals MARYSVILLE,WA 98271 PARKER,GARY RAY,PARTNER/MEMBER 425-239-6319 Doing business as SNOHOMISH County PARKER BROS HEATING LLC WA UBI No. Business type 604 266 072 Limited Liability Company Certifications &Endorsements License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. PARKEBH823JF Effective—expiration 04/06/2018—04/06/2020 Bond Western Surety Co $6,000.00 Bond account no. 64633911 Received by L&I Effective date 05/08/2019 05/0712019 Expiration date Until Canceled Bond history Insurance Farmers Ins Exchange $1,000,000.00 Policy no. 606699140 Received by L&I Effective date 05/08/2019 05/15/2018 Expiration date 0 5/1 512 0 2 0 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. Help us improve L&I Tax debts No L&I tax debts are recorded for this cont, it license during the previous 6 year period,but son._ aebts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Public Works Requirements Workplace safety and health Access A&Washinµton SUBMITTAL D , ; M-SERIES 18,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT PUMP SYSTEMS .lob Name:MUFFLY - - System Reference: INDOOR HEAD UNIT- LIVING ROOM _ Date_ Indoor Unit: Wireless Remote Controller MSZ-GL18NA i � I . - 10 GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns • Multiple fan speed options:Quiet,Low,Medium,High,Super-high,Auto • Multiple control options available: Hand-held Remote Controller(provided with unit) kumo cloud®smart device app for remote access Third-party interface options Wired or wireless controllers Hot-Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button Received JUL 8'9 2019 ho lu 0 Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights resE!rved � ' •r •,. ' MSZ-GL18NA , Btu/h 18,000 Cooling Capacity 3 I _ I � 21,600 L Btu/h Heating Capacitys 3 — Voltage,Phase,Frequency l 208/230V, 1 phase,60Hz Guaranteed Voltage Range V AC 1 187-253 Electrical Voltage: Indoor-Outdoor,S1-S2 V AC 208/230 — Voltage:Indoor-Outdoor,S2-S3 V DC 24 Voltage:Indoor-Remote Controller Wireless Type A t MCA Blower Motor Full Load Amperage A 0.67 Blower Motor Output W 30 —� Airflow Rate at Cooling,Dry CFM 646-522-417-332-258 Airflow Rate at Cooling,Wet CFM 581-470 375-299-232 Airflow Rate at Heating,Dry CFM 646-565-469-385-297 Sound Pressure Level(Cooling) dB(A) 49 44-38-33-28 Sound Pressure Level(Heating) dB(A) 48-43-38-33-28 Drain Pipe Size In.(mm) 5/8(15.88) Plate fin coil Heat Exchanger Type External Finish Color Munsell 1.OY 9.2/0.2 W:In.(mm) 36-5/16(923) Unit Dimensions D:In.(mm) 9-13/16(250) H:In.(mm) 12(305) W: In.(mm) 39(990) Package Dimensions D:In.(mm) 13(330) H: In.(mm) 15(380) Lbs.(kg) 28(13) Unit Weight Package Weight Lbs.(kg) 33(15) Refrigerant Type R410A Gas Pipe Size O.D.(Flared) In.(mm) 1/2(12.7) Piping 1/4(6.35) Liquid Pipe Size O.D.(Flared) Notes: Cooling(Indoor!/Outdoor) 'F 80 DB,67 WB//95 DB,75 WB i Nominal Conditions z °F 70 DB,60 WB//47 DB,43 WB Heating at 47°F(Indoor//Outdoor) 3Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit.For reference to connected capacity charts,please refer Multi-zone Outdoor Unit Operational Performance. Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. �,�� n_ /� e i I ACCESSORIES: MSZ-GL18NA Anti-allergy Enzyme Filter ❑MAC-408FT_E Backlit,Wall-mounted,Wireless Controller ^I MHK1 — Portable Central Controller I❑MCCH1 Wired MA Controller) —1 o PAR-33MAA Simple MA Controllers ❑PAC-YT53CRAU Touch MA Controller) ❑PAR-CT01MAU-SB Wired Remote Sensor i ❑M21-EAA-307 Wireless Temperature and Humidity Sensor ❑PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 ❑MOS1 System Control Interface2 ❑MAC-3331F-E Wireless Interface ❑PAC-USWHS002-WF-1 Thermostat Interface ❑PAC-US444CN-1 kumo station`s ❑PAC-WHS01HC-E USNAP Interface o PAC-WHS01UP-E i IT Extender ❑PAC-WHS011E-E� BACnet®and MODBUS6 Interface ❑PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers o RCMKP1CB Blue Diamond Sensor Extension Cable—15 Ft. ❑C13-103 Blue Diamond Alarm Extension Cable—6.5 Ft. ❑C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑C21-014 Blue Diamond Rubber Foot Pads ❑F10-010 Mini Condensate Pump—230 volt application I❑S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor ❑X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(110V)up to 48,000 Btu/h ❑X87-711 -110V [recommended] Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] ❑X87-721 -208/230V MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18,000 Btu/h ❑X85-003 Fascia Kit for MicroBlue Pump—mounts the MicroBlue and sensor directly beneath the indoor unit ❑T18-016 Drain Pan Level Sensor ❑DPLS2 (30A/600V/UL)[fits 2"X 4"utility box]-Black ❑TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White ❑TAZ-MS303W Requires MAC-3331F-E 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. �. � ,..1 DIMENSIONS: MSZ-GL18NA Unit: inch 711013116 Installation rate We I cortnt 1x7116 hole 3.11116 36416 3-11116 9-7/8 35-13116 114 8-11116 8-1/16 31i6 913(18 25116 15.71 1 46 ? Air in Wall hole ID3 Installation Plata piping v 2-112 2-1 16 27-15116 6-5/16 .o M a ! Drain hose 2.9116 314 _ 2.9116 `i 4.112 n v Air out 5�1q 2.9116 2.9116 ,o ` 3.11116 *InsulationID2 0-D 05/16 5-3/8 Flared connection ID1/4o. 015/32 13-3/B Flared connection 01/2 lnsulation 01-1/8 Connected art ID5/8 O.D mtMITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www,mehv.ic.com FORM#MSZ-GL18NA FOR MXZ-C MULTI-ZONE HEAT PUMP °Ow SYSTEMS-201902 Imulek Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ��. ti � � 15 y I Add to Cart Add to List Features & Benefits Specifications Documents ` Airflow Rate at Cooling, Dry 646-522-417-332-258 CFM Airflow Rate at Cooling, Wet 581-470-375-299-232 CFM Airflow Rate at Heating, Dry 646-565-469-385-297 CFM Blower Motor Full Load Amperage 0.67A Blower Motor Output 30W Cooling Capacity 18000 Btu/h Drain Pipe Size 5/8" Electrical Rating 208/230V, 1 phase, 601-lz External Finish Color Munsell 1.OY 9.2/0.2 Gas Pipe Size 1/2" O.D. (Flared) Heating Capacity 21600 Btu/h Liquid Pipe Size 1/4" O.D. (Flared) MCA 1 A Package Dimensions 39" W x 13" D x 15" H Package Weight 33 Ibs Refrigerant R410A Sound Rating (Cooling) 49-44-38-33-28 dB(A) Sound Rating (Heat) 48-43-38-33-28 dB(A) 1 Type of Heat Exchanger Plate Fin Coil Unit Dimensions 36-5/16" W x 9-13/16" D x 12" H Unit Weight 28 Ibs Voltage Range 187 - 253 VAC } ,L` v SUBMITTAL DATA: ' • / IMIMJ ' I11 • 1 1••' •'MXZ-C MULTI.ZONE HEAT PUMP SYSTEMS Job Name: MUFFLY _ system Reference: INDOOR HEAD UNIT- MASTER Date. Indoor Unit: Wireless Remote Controller MSZ-GL09NA •c�N1`, GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns • Multiple fan speed options:Quiet,Low,Medium,High,Super-high,Auto • Multiple control options available: Hand-held Remote Controller(provided with unit) kumo cloud°smart device app for remote access Third-party interface options Wired or wireless controllers Hot-Start Technology:no cold air rush at equipment startup or when restarting after Defrost Cycle Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button P,eceived JUL 2'9 &01g 01,0 /�tpglq Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved J SPECIFICATIONS: MSZ-GL09 Cooling Capacity 1,3 Btu/h 9,000 I Heating Capacityz 3 Btu/h 10,900 phase,60Hz 1 p Voltage,Phase,Frequency 208/230V, _ Guaranteed Voltage Range V AC 187-253 Electrical Voltage: Indoor-Outdoor,S1-S2 VAC 208/230 Voltage:Indoor-Outdoor,S2-S3 V DC 24 Voltage:Indoor-Remote Controller [ Wireless Type A i MCA _ _ - Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 399-321-237-170-145 Airflow Rate at Cooling,Wet CFM1��364-286-2011-134-1109 Airflow Rate at Heating,Dry CFM 406 321-237 170 145 Sound Pressure Level(Cooling) dB(A) 43-37-30-22-19 Sound Pressure Level(Heating) dB(A) I 43-37-30-22-19 Drain Pipe Size In.(mm) 5/8(15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.OY 9.2/0.2 W:In.(mm) 31-7/16(798) Unit Dimensions D:In.(mm) 9-1/8(232) H:In.(mm) 11-5/8(295) W:In (mm) 1 33-1/2(850) _I I Package Dimensions D:In.(mm) 12(300) H:In.(mm) 14(350) Unit Weight Lbs.(kg) 22(10) Package Weight I Lbs. (kg)_ I 26(11.5) Refrigerant Type R410A Gas Pipe Size O.D.(Flared) In.(mm) 1 3/8(9.52) Piping — � Liquid Pipe Size O.D.(Flared) In.(mm) I 114(6.35) Notes: Cooling(Indoor//Outdoor) °F 80 DB,67 WB//95 DB,75 WB Nominal Conditions 2 °F 70 DB,60 WB//47 DB,43 WB Heating at 47°F(Indoor//Outdoor) 3Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit.For reference to connected capacity charts,please refer Multi-zone Outdoor Unit Operational Performance. Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC-All rights reserved. �' �::J 09 , Anti-allergy Enzyme Filter ❑MAC-408FT-E Backlit,Wall-mounted,Wireless Controller —�❑MHK1 Portable Central Controller ❑MCCH1 Wired MA Controller) I❑PAR-33MAA �I Simple MA Controller) ❑PAC-YT53CRAU Touch MA Controller) ❑PAR-CT01 MAU-SB Wired Remote Sensor ❑M21-EAA-307 Wireless Temperature and Humidity Sensor ❑PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 ❑MOS1 System Control Intertacez ❑MAC-3331F-E Wireless Interface ❑PAC-USWHS002-WF-1 Thermostat Interface �I❑PAC-US444CN-1 kumo station u ❑PAC-WHS01HC-E USNAP Interface �I Li PAC-WHS01UP-E IT Extender ❑PAC-WHS011E-E _ 1 BACnet°and MODBUS©Interface ❑PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers ❑RCMKP1CB Blue Diamond Sensor Extension Cable—15 Ft. o C13-103 Blue Diamond Alarm Extension Cable—6.5 Ft. c C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑C21-014 `Blue Diamond Rubber Foot Pads ❑F10-010 Mini Condensate Pump—230 volt application ❑S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor ❑X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(110V)up to 48.000 Btu/h ❑X87-711 -110V [recommended] Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] ❑X87-721 -208/230V MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18,000 Btu/h ❑X85-003 Fascia Kit for MicroBlue Pump—mounts the MicroBlue and sensor directly beneath the indoor unit ❑T18-016 Drain Pan Level Sensor o DPLS2 (30A/600V/UL)[fits 2"X 4"utility box]-Black ❑TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White ❑TAZ-MS303W �I Requires MAC-3331F-E 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC_All rights resE!rved, ';�1 �: .� 1 • 1 ' ' , Unit: inch 1116x1 Oblong hole lll6x13116 Oblong Ale Inslallollon late 1! t18 8 Il Il . mj 31-1/16 30 I5/16 oviii 6-IIB � 6 I/8 1 - 116 139! 6A!r i of I hole 03 I J�/L Inslollollon Plate u m �I Pi 1n 1 V8 /l6 24�3! 3•I! �•- ^1" 4- /16.�' Drorn hose 4.3! 116 _ 14 �` A I r outt Liquid line o1/4 19-11/16 Flared connection o114) a Gas line o3/6 16-15/16 L� 311 o 15!16 _ (Flared connection:e3/0(GL06109A2NA),o112(GLISNA)) Drain hose Insulation of-116 O.D Connected part o5/6 0.13 atMITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 wwwmehvoc.com FORM#MSZ-GL09NA FOR MXZ-C MULTI-ZONE HEAT PUMP 0. SYSTEMS-201902 Ir erfek Specifications are subject to change without notice. ©2019 Mitsubishi Electric Tirane HVAC US LLC.All rights reserved. ., � ' i , i :; r� I' Add to Cart l Add to List Features & Benefits Specifications Documents - 37-170-145 CFM Dr 399 321 2 Airflow Rate at Cooling, y Airflow Rate at Cooling,Wet 364-286-201-134-109 CFM Airflow Rate at Heating, Dry 406-321-237-170-145 CFM Blower Motor Full Load Amperage 0.76A Blower Motor Output 30W Cooling Capacity 9000 Btu/h Drain Pipe Size 5/8" Electrical Rating 208/230V, 1 phase, 601-lz External Finish Color Munsell 1.OY 9.2/0.2 Gas Pipe Size 3/8" O.D. (Flared) Heating Capacity 10900 Btu/h Liquid Pipe Size 1/4" O.D. (Flared) MCA 1 A Package Dimensions 33-1/2" W x 12" D x 14" H Package Weight 26 Ibs Refrigerant R410A Sound Rating (Cooling) 43-37-30-22-19 dB(A) Sound Rating (Heat) 43-37-30-22-19 dB(A) Type of Heat Exchanger Plate Fin Coil i I Unit Dimensions 31-7/16" W x 9-1/8" D x 11-5/8" H Unit Weight 22 Ibs Voltage Range 187 - 253 VAC SUBMITTAL DATA: 1 1 1 tttt Rl Job Name:MUFFLY _ System Reference: OUTDOOR UNIT Date: ler Indoor Unit: Outdoor Unit: Wireless Remote ContrA MSZ-D30NA MUZ-D30NA �11 till GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control. • The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns. • INVERTER-driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Multiple fan speed options:Low,Medium,High,Powerful,Auto • Multiple control options available: Hand-held Remote Controller(provided with unit) kumo cloud°smart device app for remote access Third-party interface options Wired or wireless controllers Hot-Start Technology:no cold air rush at equipment startup or when restarting after Defrost Cycle Powerful Operation:quickly cools or heats the room by automatically adjusting fan speed and set temperature for 15 minutes • Smart Set:recalls a preferred preset temperature setting at the touch of a button • Wide Vane mode provides 150'of airflow Received JUL 2'9 201g �Lb Wq;J Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reSE,rved. ., V I • / MSZ.D30NA • 1 Maximum Capacity Btu/h 30,700 Rated Capacity Btu/h t 30,700 Minimum Capacity Btu/h 9,800 Maximum Power Input W , 3,850 Coolingi -- Rated Power Input W 3,850 Moisture Removal Pints/h 9.9 Sensible Heat Factor 0.64 Power Factor % 99/99 Maximum Capacity I Btu/h 34,000 Rated Capacity Btu/h 32,600 Minimum Capacity Btu/h 8,700 Heating at 47°Fz — - - - Maximum Power Input W 3,600 Rated Power Input W 3,360 Power Factor % 99/99 i Maximum Capacity Btu/h 20,800 Rated Capacity Btu/h 19,500 Heating at 17°F3 — — Maximum Power Input W 2,620 Rated Power Input I W 2,620 SEER 14.5 EERY T - - — - — 8.0 Efficiency HSPF(IV) 8.2 COP at 47°F2 2.84 COP at 17°F in Maximum Capacity3 2.33 Voltage,Phase,Frequency JI 208/230V,1 phase,60Hz Guaranteed Voltage Range VAC 187-253 Voltage: Indoor-Outdoor,S1-S2 VAC 208/230 Electrical Voltage: Indoor-Outdoor,S2-S3 V DC 24 Voltage: Indoor-Remote Controller Wireless Type Recommended Fuse/Breaker Size A 25 Recommended Wire Size(Indoor-Outdoor) AWG 14 MCA A 1 MOCP A 15 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 56 Airflow Rate at Cooling,Dry CFM I 887-848-639-389 Indoor Unit Airflow Rate at Cooling,Wet CFM I 798-763-576-350 Airnow Rate at Heating,Dry CFM 887-848-639-445 Sound Pressure Level(Cooling) dB(A) 51-49-42-32 Sound Pressure Level(Heating) dB(A) 50-49-42-34 Drain Pipe Size In.(mm) 5/8(15.88) Heat Exchanger Type Plate fin coil Specifications are subject to change without notice- ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. �,L,+ '�J I • • 1 1 1 I ' , External Finish Color Munsell 3Y 7.811.1 W:In.(mm) 46-1/16[1,170] Unit Dimensions D: In.(mm) 11-5/8(295) H:In.(mm) 14-3/8(365) W:In.(mm) 51 (1,295) Package Dimensions D:In.(mm) 14-1/4(362) H: In.(mm) 18-1/2(470) Unit Weight Lbs.(kg) 40(18) Package Weight Lbs.(kg) 53(24) Indoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum)" 'F j 90 DB,73 WB/67 DB,57 WB Temperature Range Heating Intake Air Temp(Maximum/Minimum) 'F 80 DB/70 DB ~ - - MCA A 21 MOCP , A 25 Fan Motor Full Load Amperage A 0.93 Fan Motor Output W 77 Airflow Rate CFM 1,941 11,941 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level,Coolingi dB(A) 55 Sound Pressure Level,Heating2 dB(A) 57 Compressor Type DC INVERTER-driven Compressor Model TNB220FMCHT Outdoor Unit Compressor Rated Load Amps A 26 Compressor Locked Rotor Amps A 20 Compressor Oil Type 1/Charge !fi oz NEO22//29.4 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater N/A W: In.(mm) 33-1/16(840) Unit Dimensions D: In.(mm) 13(330) H:In. (mm) 33-7/16(850) W: In.(mm)--r 39(990) Package Dimensions D:In.(mm) 18 1/2(470) ~I H:In.(mm) 39 3/4(1,010) Unit Weight Lbs.(kg) 141 (64) Package Weight Lbs.(kg) 168(76) Cooling Air Temp(Maximum/Minimum)" 'F 115/14 Outdoor Unit Operating Cooling Thermal Lock-out/Re-start Temperatures" °F -4/0 Temperature Range Heating Air Temp(Maximum/Minimum) - °F 14 to 75 Heating Thermal Lock-out/Re-start Temperatures`" °F N/A �I Refrigerant Type R410A Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights resE,rved. SPECIFICATIONS: 1 1 , r Charge Lbs,oz 4. 10 Gas Pipe Size O.D.(Flared) In.(mm) 5/8(15.88) Liquid Pipe Size O.D.(Flared) I In.(mm) 3l8(9.52) Piping Maximum Piping Length Ft.(m) 100(30) Maximum Height Difference Ft.(m) 50(15) Maximum Number of Bends 10 Notes AHRI Rated Conditions Cooling(Indoor//Outdoor) �F 80 DB,67 WB//95 DB,75 WB (Rated data is 2Heating at 47°F(Indoor//Outdoor) T 70 DB,60 WB I/47 DB,43 WB determined at a fixed - - ——1 compressor speed) 31-leating at 17°F(Indoor//Outdoor) T 70 DB,60 WB//17 DB,15 WB *Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature condit ons. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights resE!rved. l.w. y _ - - _ _ _ - - - - - - - - - - - - - - ter ACCESSORIES: 1 1 ❑MAC-811 DS Drain Socket _ _ -- Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic ❑DSD-400P Condensing Unit Mounting Pad 16"x 36"x 3" I❑ULTRILITE1 Outdoor Unit Stand—12"High ❑QSMS1201 M Outdoor Unit Stand—18"High ❑QSMS1801M — ❑QSMS2401M Outdoor Unit Stand—24"High _ Heavy Duty Wall Mounting Bracket—Coated Steel r,QSWB2000M-1 Heavy Duty Wall Mounting Bracket—316 Series Stainless Steel _ — ❑QSWBSS 10'x 3/8"x 10'x 5/8"Lineset(Twin-Tube Insulation) ❑MPLS385812T-10 15'x 3/8"x 15'x 5/8"Lineset(Twin-Tube Insulation) Li MPLS385812T-15 f30'x 3/8"x 30'x 5/8"Lineset(Twin-Tube Insulation) ❑MPLS385812T 30 50'x 3/8"x 50'x 5/8"Lineset(Twin-Tube Insulation) ❑MPLS385812T 50 5/8"Lineset(Twin-Tube Insulation) JE1 MPLS385812T-65 100'x 3/8"x 100'x 5/8"Lineset(Twin-Tube Insulation) ❑MPLS385812T-100 Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights resE!rved. 1 • MUZ-D30NA Unit: inch REQUIRED SPACE Open as a rule 20 in.or more if the front and both sides 20-9/32 are open Grain 3 holts 11-25/32 l 9/16 InI-6/l61 2-19/32 Ar re 4 in.or more/ r e 9�n 8 in.or more if aiah there are obstacles 4 to both sides Air sul 4-3/Bal3/16 slot 19-11/16 Open as a rule 33-1i16 3 y16 20 in.or more if the back, A-2S/3 both sides and top are open O M I v liquid:3/6 c ' Gas :5/6 M AAMITSUBISHI W ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehv,ac.com a 0. FORM#MSZ-D30NA I MUZ-D30NA-201902 Intertek Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. � i i i � ..� i I Airflow Rate 1941 CFM Compressor Locked Rotor Amps 20A Compressor Oil Type/Charge NE022// 29.4 oz. or Rated Load Amps s 26A p Compressor Type DC INVERTER-Driven Cooling Capacity Ca acit 30700 BTU/Hr Cooling Capacity acity Range 115 / 14 OF Defrost Method Reverse Cycle EER 8.0 Electrical Rating 208/230V, 1 phase, 601-lz External Finish Color Munsell 3Y 7.8/1/1 Fan Motor Full Load Amperage 0.93A Fan Motor Output 77W Gas Pipe Size 5/8" O.D. (Flared) Heating Capacity 32600 Btu/h Heating Temperature 14 to 75 OF HSPF 8.2 Liquid Pipe Size 3/8" O.D. (Flared) Maximum Height Difference 50 Ft. Maximum Number of Bends 10 Maximum Piping Length 100 Ft. MCA 21 A i MOCP 25A Package Dimensions 39" W x 18-1/2" D x 39-3/4" H Package Weight 168 Ibs Refrigerant R410A Refrigerant Charge 4 Ibs, 10 oz. Refrigerant Control LEV Seer 14.5 Sound Rating (Cooling) 55 dB(A) Sound Rating (Heat) 57 DB(A) Type of Heat Exchanger Plate Fin Coil Unit Dimensions 33-1/16" W x 13" D x 33-7/16" H Unit Weight 141 Ibs Voltage Range 187 - 253 VAC ,� a �� I I o NOTICE TO PERMITEE AND/OR OWNER Cl PARTIAL APPROVAL Cl CORRECTIONS REQUIRED ❑ DO NOT OCCUPY ,XAPPROVED PERMIT#: J- 2V?, LOT#: DATE: ��. JOB ADDRESS: TYPE OF INSPECTION: � ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK:MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE T— , M BUILDING DEPT. 0 PLANNING DEPT. CITY OF ARLINGTON ' • RESIDENTIAL MECHANICAL ® PERMIT APPLICATION �IN � Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:213 N Lenore Ave Project Description:Install Heat Pump - 1 Outdoor Unit & 2 Indoor Head Units Owner: Paul Muffly Address: 213 N Lenore Ave City:Arlington StateYVA Zip Code: 98223 Phone: 425-501-2748 Email:paul_muffly@hotmail.com Applicant: Parker Bros Heating - Natalie Poma Address: 13630 54th Dr NE City: Marysville State WA Zip Code: 98271 Phone: 360-572-0108 Email: natalie@parkerbroselectric.com CONTRACTOR INFORMATION Contractor Name•Parker Bros Heating Address: 13630 54th Dr NE City: Marysville State.WA Zip Code: 98271 License Number:PARKEBH823JF Expiration: 04/06/2020 Phone: 360-572-0108 Email:admin@parkerbrosheating.com STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION L,Nt'� Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model # AFUE �j Heat Pump Model #MHP MUZD30NA-1 AFUE HSPE8.2 ❑ AC Unit Model # SEER 14.5 Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ I� Gas Piping ❑ Solid-Fuel Appliance ❑ Other - Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date: Applicant Printed Name: I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:213 N.Lenore Ave Permit#:2693 Parcel#:00455400200700 Valuation:0.00 OWNER APPLICANT * CONTRACTOR _ Name:MUFFLY PAUL W JR/BELAN ALISSA J Name:Parker Bros Heating Name:Parker Bros Heating Address:213 N DUNHAM Address:13630 54th Dr NE Address: 13630 54th Dr NE City,State Zip:ARLINGTON,WA 98223 City,State Zip:Marysville City,State Zip:Marysville,WA 98271 Phone: Phone:360-572-0108 Phone:360-572-0108 LIC:PARKEBH823JF EXP:04/06/2020 MECHANICAL CONTRACTOR = PLUMBING CONTRACTOR Name:Parker Bros Heating Name: Address: 13630 54th Dr NE Address: City,State,Zip:Marysville,WA 98271 City,State,Zip: Phone:360-572-0108 Phone: LIC#:PARKEBH823JF EXP: 04/06/2020 LIC#: EXP: JOB DESCRIPTION V PERMIT TYPE: Residential Mechanical CODE YEAR: 2018 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. r� 1;f-� 7/30/2019 Signature Print Name Date Yeleased Date CONDITIONS 3" concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated; use of adhesive tapes are prohibited. Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 7/30/2019 Heat Pump $75.00 7/30/2019 Mechanical Permit Base Fee $25.00 7/30/2019 Processing/Technology Fee $25.00 Total Due: $125.00 Total Payment: $0.00 Balance Due: $125.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 2693 Permit Date: 07/30/19 Permit Type: RESIDENTIAL MECHANICAL Project Name: Muffly Applicant Name: Parker Bros Heating Applicant Address: 13630 54th Dr NE Applicant, City, State, Zip: Marysville Contact: Phone: 360-572-0108 Email: admin@parkerbroselectric.com Scope of Work: Install heat pump/ I outdoor unit and 2 indoor head units Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: Form Permit Type: Status: EXPIRED Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning MUFFLY PAUL W 00455400200700 213 LENORE AVE JR/BELAN Residence Single Family -Detached ALISSA J Contractors Contractor Primary Contact Phone Address Contractor Type License License# Parker Bros Heating 360-572-0108 13630 54th Dr NE CONSTRUCTION L&I PARKEBH823JF CONTRACTOR Fees Fee Description Notes Amount Heat Pump/Heat Exchangers 3 @$25 ea. $75.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Total $125.00 Attached Letters Date Letter Description 07/30/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 07/30/2019 Gary Parker 76354553 $125.00 Outstanding Balance $0.00 Uploaded Files Date File Name O1/15/2020 6113728-2693 8-15-19IC.pdf 07/30/2019 5389496-2693 Application.pdf