Loading...
HomeMy WebLinkAbout9111 Tveit Rd_BLD2668_2026 NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED Cl DO NOT OCCUPY XAPPROVED PERMIT#: t �`� IAM�IPM D_A_TE_: 3 OBADDRESS: �l( I I r t �-} t�, LOT#: PROJECT: (1P € . ,,�, - TYPE OF INSPECTION: OTHER: Cl NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE v � O PLANNING O CIVIL Q/BUILDING • / CITY OF ARLINGTON CITY OF ARLINGTON 18204 59th Avenue NE,Arlington, WA 98223 INSPECTIONS:360-403-3417- Permit Center: 360-403-3551 BUILDING PERMIT Permit#:2668 91l It Tveit Rd. Permit Expiration Date: Parcel#: 31051200100500 Valuation: 2000.00 OWNER APPLICANT CONTRACTOR REACH VERNON Northwest Pipeline JTi Commercial Services,LLC 9111 TVEIT RD 22909 NE Redmond Fall City Rd 1006 Central Rd. ARLINGTON, WA 98223 Redmond,WA 98053 Everson,WA 98247 425-301-1068 360-815-0693 LIC:JTICOTI955 DG t3XP:03/31/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LTC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Accessory Structure CODE YEAR: 2015 STORIES: I CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order, proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance, regulation or order,state or federal law,or any order,proclamation, guidance or decision of the Governor. I AGRF,F,TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING TIE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HTS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN - MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI l0/IRCI l0. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return firm and coded City of Arlington#3101. Clay R. Gustaves 7/15/2020 Signature Print Name Date Re cased 13y D.uc CONDITIONS Adhere to approved plans.Call for inspections. TIJIS PEIWIT AUTHORIZES ONLY THE WORK NOTED, THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CO .'RUCTION ON THE PUBLIC DOMAIN(CU. n SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PER1*IIT FEES Date Description Fee Amount 07/15/2020 Building Permit Fee $100.70 0711 5/2 0 20 Building Plan Review Fee $65.46 07/15/2020 Processing/Technology Fee $25.00 07/15/2020 State Building Code Surcharge Fee $6.50 07/15/2020 Credit Card Surcharge $5.93 Total Due: $203.59 Total Payment: $203.59 Balance Due: $0.00 CrALL.FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY OF ARLINGTON ' / 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 9111 Tveit Rd. Permit#: 2668 Permit Expiration Date: Parcel#: 31051200100500 Valuation:2000.00 OWNER APPLICANT CONTRACTOR BEACH VERNON Northwest Pipeline JTI Commercial Services,LLC 9111 TVEIT RD 22909 NE Redmond Fall City Rd 1006 Central Rd. ARLINGTON,WA 98223 Redmond,WA 98053 Everson,WA 98247 425-301-1068 360-815-0693 LIC:JTICOTI955DG EXP:03/31/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Accessory Structure CODE YEAR: 2015 STORIES: 1 CONST. TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law, or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order, state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC 110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Re eased By Date CONDITIONS Adhere to approved plans. Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CO' 'RUCTION ON THE PUBLIC DOMAIN(C' IS,SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PEkMISSION. PERMIT FEES Date Description Fee Amount 07/15/2020 Building Permit Fee $100.70 07/15/2020 Building Plan Review Fee $65.46 07/15/2020 Processing/Technology Fee $25.00 07/15/2020 State Building Code Surcharge Fee $6.50 07/15/2020 Credit Card Surcharge $5.93 Total Due: $203.59 Total Payment: $203.59 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon GITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 4D PHONE; (360) 403-3551 BUILDING PERMIT Address:9111 Tveit Rd. Permit#:2668 Parccl#:31051200100500 Valuation:2000.00 OWNER APPLICANT CONTRACTOR Name:BEACH VERNON Name:Northwest Pipeline Name:1TI Commercial Se- es,LLC Address:9111 TVEIT RD Address:22909 NE Redmond Fall City Rd Address: 1006 Central RV City,State Zip:ARLINGTON,WA 98223 City,State Zip:Redmond,WA 98053 City,State Zip:Everso ,WA 98247 Phone: Phone:425-301-1068 Phone:360-815-06� LIC:ITICOTl95 G EXP:03/31/2021 MECHANICAL CONTRACTOR PLUMBING CONTRA OR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Accessory Structure CODE YEAR: 2015 STORIES: I CONST.TY DWELLING UNITS: OCC GR P: BUILDINGS: OCC L AD: PERMIT APP OVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS/1fB%l0IRCI10, G CO TRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF CO :OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNEU DING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING URE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTIRC110.SALES TAX NOTICE:Sales tax relating to construction n materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print N ne Date Rcleascd By Da CONDITIONS Adh e to approved plans. Call for inspections. THIS PERMIT AUTHORIZES ONLY TH uORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC pOPo IN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Descri ton Fee Amount 7/31/2019 Buildi g Permit Fee $100.70 7/31/2019 Bui ing Plan Review Fee $65.46 7/31/2019 P ocessing/Technology Fee $25.00 7/31/2019 tate Building Code Surcharge Fee $6.50 Total Due: $197.66 Total Payment: $197.66 Balance Due: $0.00 CALL F INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon I Raelynn Jones From: Gustaves, Clay <Clay.Gustaves@Williams.com> Sent: Wednesday, July 15, 2020 2:01 PM To: Raelynn Jones Subject: RE: Northwest Pipeline Equipment Shelter [NOTICE: This message originated outside the City of Arlington mail system.-- DO NOT CLICK on links or open attachments unless you are sure the content is safe.] No changes to the plans from 2019. JL �tiuv� Senior Land Representative Williams—Northwest Pipeline 22909 NE Redmond Fall City Rd Redmond,WA 98053 (425)301-1068 mobile From: Raelynn Jones<rjones@arlingtonwa.gov> Sent:Wednesday,July 15, 2020 2:00 PM To:Gustaves, Clay<Clay.Gustaves@Williams.com> Subject: [EXTERNAL] RE: Northwest Pipeline Equipment Shelter Good Afternoon Clay, Are there any changes to the plans since 2019? Please advise Sincerely, Raelynn Jones Permit Technician City of Arlington Community& Economic Development 18204 59th Ave NE Arlington, WA 98223 Office: 360-403-3436 www.ariingtonwagoov 1 From: Gustaves,Clay<Clay.Gustaves@Williams.com> Sent:Tuesday,July 14, 2020 1:08 PM To: Raelynn Jones<riones@arlingtonwa.gov> Subject: RE: Northwest Pipeline Equipment Shelter Importance: High [NOTICE: This message originated outside the City of Arlington mail system.-- DO NOT CLICK on links or open attachments unless you are sure the content Is safe.] Any updates on anticipated issue date on the building permit Raelynn?We are scheduled to go to construction in a couple of weeks. Thanks, Senior Land Representative Williams—Northwest Pipeline 22909 NE Redmond Fall City Rd. Redmond,WA 98053 (425) 301-1068 mobile From:Gustaves, Clay Sent:Tuesday,June 30, 2020 2:54 PM To: 'Raelynn Jones' <riot nes arlingtonwa.gov> Subject: RE: Northwest Pipeline Equipment Shelter Thank you very much. I'm sorry that I didn't think the 180 days started until I picked the permit up. My mistake. From: Raelynn Jones<riones@arlingtonwa.gov> Sent:Tuesday,June 30, 2020 1:17 PM To: Gustaves, Clay<Clay.Gustaves@Williams.com> Subject: [EXTERNAL] RE: Northwest Pipeline Equipment Shelter Good Afternoon Clay, Let me look into this for you.The permit that is ready to issue was dated 7/2019 and has exceeded the 180 days for time limitation. However, I will speak with our Building Official and see if he is able to assist in this situation. I will reach out once I have had a chance to speak with him.Thank you! 2 Sincerely, Raelynn Jones Permit Technician City of Arlington Community& Economic Development 18204 59`h Ave NE Arlington, WA 98223 Office: 360-403-3436 www.arlingtonwa.gov From:Gustaves, Clay<Clay.Gustaves@WilIiams.com> Sent: Monday,June 29, 2020 5:27 PM To: Raelynn Jones<riones@arlingtonwa.gov> Subject: RE: Northwest Pipeline Equipment Shelter [NOTICE: This message originated outside the City of Arlington mail system.-- DO NOT CLICK on links or open attachments unless you are sure the content is safe.] Raelynn, I hope you and your family are well during these peculiar times.This project was postponed a year and is now scheduled for August 3 d, 2020. 1 am assuming I still have a permit to pick up at City Hall. Is that a valid assumption?Thanks for letting me know. C 91 Senior Land Representative Williams—Northwest Pipeline 22909 NE Redmond Fall City Rd. Redmond, WA 98053 (425) 301-1068 mobile From: Raelynn Jones<riones@adingtonwa.gov> Sent: Wednesday,July 31, 2019 1:09 PM To: Gustaves, Clay<Clay.Gustaves@Williams.com> Subject: [EXTERNAL] RE: Northwest Pipeline Equipment Shelter 3 Hi Clay, Looks like we've got their application for the business license. I have the permit packet ready for pickup- pending business license payment for JTI of which I have sent payment information to them.Thank you for your help! Sincerely, Raelynn Jones Permit Technician City of Arlington Community& Economic Development 18204 59th Ave NE Arlington, WA 98223 Office: 360-403-3436 www.arlingtonwa.gov From:Gustaves, Clay<Clay.Gustaves@Williams.com> Sent:Wednesday,July 31, 2019 12:06 PM To: Raelynn Jones<r0ones@arlingtonwa.9ov> Subject: RE: Northwest Pipeline Equipment Shelter [NOTICE: This message originated outside the City of Arlington mail system.-- DO NOT CLICK on links or open attachments unless you are sure the content is safe.] Raelynn, JTI Commercial Services will be the contractor and I think they have very recently applied for the license. Thanks, Clay From: Raelynn Jones<rjones arlin onwa.gov> Sent:Tuesday,July 30, 2019 11:37 AM To:Gustaves, Clay<Clay.Gustaves@Williams.com> Subject: [EXTERNAL] RE: Northwest Pipeline Equipment Shelter Good Morning, 4 I am following up in regards to my previous email regarding a business license for Northwest Pipeline. Have you had a chance to submit the application?We are ready to move forward with issuance of the permit for the equipment shelter, pending a business license. Please advise.Thank you! Sincerely, Raelynn Jones Permit Technician City of Arlington Community& Economic Development 18204 59th Ave NE Arlington, WA 98223 Office: 360-403-3436 www.arlingtonwa.gov r I ` From: Raelynn Jones Sent:Tuesday,July 16, 2019 9:53 AM To: clay.gustaves@williams.com Cc: Kristin Foster<kfoster arlin tonwa.goy>; Launa Peterson<Ieterson@arlingtonwa.gov> Subject: RE: Northwest Pipeline Equipment Shelter Also,the City of Arlington requires any contractor working within City limits obtain a business license.The application to complete is attached or you may follow the link below to apply online. Please email the completed application to ced@arlingtonwa.gov for processing. Once we receive the application and process we'll email with a link to make the payment online. htt :,/Lwww.arlingtonwa.gov/432/Business-License-Applications Let me know should you have any questions. Thank you, Raelynn Jones Permit Technician 1 18204 59th Ave NE Arlington, WA 98223 360-403-3436 www.arlingtonwa.gov 5 From: Raelynn Jones Sent:Tuesday,July 16, 2019 9:49 AM To: clay.gustaves@williams.com Cc: Kristin Foster<kfoster@arlin9tonwa.eov>; Launa Peterson <ILe_t_ers_o_n&arli_npton_w_a. ov> Subject: Northwest Pipeline Equipment Shelter Good Morning Clay, We are working on processing the permit application for the equipment shelter at 9111 Tveit Rd. We are needing the site plan for the project so that we can move forward with the review process.You may email the site plan or bring it to our office. We are open 8 am to 5 pm M-F and closed from noon to 1pm for lunch.Thank you! Sincerely, Raelynn Jones Permit Technician City of Arlington Community& Economic Development 18204 59th Ave NE Arlington, WA 98223 Office: 360-403-3436 www.arlingtonwa.gov This email originates outside of Williams. Use caution if this message contains attachments, links or requests for information. 6 This email originates outside of Willir. .s. Use caution if this message contains atcments, links or requests for information. This email originates outside of Williams. Use caution if this message contains attachments, links or requests for information. This email originates outside of Williams. Use caution if this message contains attachments, links or requests for information. RESIDENTIAL PERMIT APPLICATION f Department of Community & Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE, ADDITION, DECK, OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF CONSTRUCTION DRAWINGS AND TWO(2)SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING VERIFICATION MAY BE SUBMITTED PRIOR. Project Address: 9111 Tveit RD, Arlington, WA 98223 Plat: NA �j Single-family ❑ Duplex ❑ Townhouse ❑ Addition ie: Accessory structure Proposed Area: 1" Floor: 2Id Floor: Garage: Shelter Total SF: 280 Describe Proposal (include cross street): Replace existing 20ft x 14ft detached equipment shelter/canopy with new. Valuation: $2000.00 Owner: Northwest Pipeline LLC Address: 22909 NE Redmond Fall City Road City: Redmond State: WA Zip Code:98053 _ _ _ Phone: 425-301-1068 Email: Clay.Gustaves@Williams.com Applicant:Clay Gustaves Address: 22909 NE Redmond Fall City Road City: Redmond State: WA Zip Code:98053 Phone: 425-301-1068 Email:Clay.Gustaves@Williams.com Contractor: Northwest Pipeline LLC Address: 22909 NE Redmond Fall City Road_City:Redmond State:WA Zip Code:98053 Phone: 425-301-1068 Email: Clay.Gustaves@Williams.com Contact Person:Clay Gustaves License Number:603 325 992 Expiration: 8/31/2019 Received JUL 116 2019 6/16LP Page 1 of 3 'Y RESIDENTIAL PERMIT APPLICATION ' Department of Community & Economic Development 'Y O' City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551 tr, G'1 Plumbing Section (continue filling out if plumbing is involved) (Check all that apply and indicate the number of fixtures proposed) ❑ Bath/Shower Combo (4.0) x ❑ Sink (1.5) x ❑ Shower (2.0) x ❑ Lavatory (1.0) x ❑ Clothes Washer (4.0) x ❑ Water Closet (2.5) x ❑ Dishwasher (1.5) x ❑ Water Heater x ❑ Hose Bibb (2.5) x Water Heater Model # ❑ Other (list) x Plumbing Section Continued Proposed Water Piping Size: Proposed DWV Material: Proposed Piping Material: Proposed DWV Size: • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) 6/16LP Page 2 of 3 RESIDENTIAL PERMIT APPLICATION Department of Community & Economic Development y�+ O City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551 Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: ❑ Furnace (80+) Model# AFUE ❑ Heat Pump Model # SEER HSPE ❑ AC Unit Model # SEER ❑I Type II Hood ❑ Commercial Cooking Appliance ❑ Hydronic Piping ❑ Boiler ❑ Solid-Fuel Appliance ❑ PV System ❑ Fireplace Insert ❑ Outdoor BBQ ❑ Storage Tank ❑ Freestanding Stove ❑ Gas Piping ❑ Other Gas Piping Information Not Applicable: P� Pipe Material: Pipe Size: Total BTU's of all Appliances: Distance from Meter to Furthest Appliance: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances ��ln.J�ccat�,r�etL Applicant Signature: M Date: 07/12/2019 Print Applicants Name; Clay Gustaves 6/16LP Upload File Date File Uploaded B 7/16/2019 9:42:38 AM 11668 ARpiication.pdf Jones, Raelynn k • Permit Information Date 7/16/2019 Permit Number 2668 Project Name Northwest Pipeline Equipment Shelter Applicant Name Northwest Pipeline Applicant Address 22909 NE Redmond Fall City Rd City,State,Zip Redmond,WA 98053 Contact Clay Gustaves Phone 425-301-1068 Email clay.gustaves@williams.com Permit Type Residential Accessory Structure Site Address 9111 Tveit Rd. Valuation MOM Status Applied Permit Issued Permit Expires Square Feet 280 Type of Construction/Occupancy Load Accessory Structure Number of Stories 1 Proposed Use Replace existing 20'x14'detached equipment shelter/canopy with a new one MIC/Opportunity Zone Assigned To Raelynn Jones Property Parcel Address Legal Owner Owner Phone Zoning 31051200100500 9111 TVEIT RD I IBEACH VERNON 111 Single Family Residence-Detached Review Date Type Description Tar et Date Completed Date Assi ned To Status /16/2019 Residential Accessory Structure Puildin In Review /16/2019 Residential Accessory Structure /23i2019 Oosh Grandlienard In Review Fees Fee Description Notes Amount Building Permit Fee 322.10.00.00 $100.70 Building Plan Review Fee 345.83.00.00 $65.46 Processing/Technology Fee 341.43.00,02 $25.00 State Building Code Surchar e Fee 386.00.01.00 $6.5U Total $197.66 Notes Date Note 7/16/2019 Emailed for site plan Uploaded Files l!S'6-*Of—£'OS' •XVJ ct=oi. "ml-wv = 2 5060-60f-£OS Hdi MN an tr 4oVIL 9M6 NOJ34Y0 7137VS OY06 Xoe 'o d N4f�d �Wb'�Jd 35'v'd a131"t3H5 1N3Wdl�t�3 '7NI .ONI&33NI,ON3 3113KV77Gt1 �3�N1�N3 3Nl'1gdid MN SNdi-I�IM Z 0 F a m o m zw A O�w zI wc5o ~ W ! ZD=U N� FW-I' g 0 i� cnw ^z N o- m 000� oW va J¢ o W O N Uj ZZ ~ X m ~ II W � �] = HJ J W Q ° O O = x Lii�W [V ' CHn cV m Ca O LLJ '- N T o z o W Q Qa Q _I cl� W O I ,z- \ 7 J � uj t W I � J v 0m~� ��L �--�_ _ ¢ J,,W o=¢o _ U ie i4 0 N O J,L Ui Q O O < V Q U W _ W W Z O U o "n 'wa l �wmo o mm J aaz Fm = =O W Z O N nm .� ❑aZ W W O w� . rm a� m=. �OZ W O = w- zPWa n mF F �z = } �oZ o Wx2 Q 11)� mzuM------ - - n� � Z-3L < Q �W� LLJ -9 z W (1N08J) 0-til w om a-mW ^V 1.L in F Q O UJ - Z w- O II U O w w Z Q H w o S O w i n M O� < FF �") Z K Wd U O w w Z J U o co OF � C) d. zo 00 00 ZO m O¢ LLJ p � p Z ZO W U o o �¢ J �I O CD;;it N O w U ¢ - d > O LLJZ > Q to V) N W p SO Ln ¢ d 0 > N O IL>- = O a p0 4 F W 3 u'1 w O m (n k Q O O w >Or LJ O Z y y fFn¢ =p 0 Z � p�� m m� !n � �• �r �� w 3 w cn cn w W U N U¢ p J m¢J O ¢ w W J C. FO ¢0 0 M p¢ ~ N Q d ¢ ` S U W W W J a cn a Z w J p p O O 1 FOZ mw > >W g , w d w U in ffYY! 0 �QFO ZZ Sw "O - O� O 0 �Q ¢ Q (n mV, OL"Z JU > 1 ZZO n ¢ U w IILLI Ln ¢ Z - O Q J In 8 V I woo � pp p w z , - rnz m �,� W (l) ao� ��� LnnF o � z � Cn ¢¢°� o : o p �o o w �r. W ��� �w� ZZ c� 3 ^ W wm�F o o �¢ z¢ �® F z Gi vi U 0<8 c<n o f =' CD w x o¢ w F c~n J U Z FQOJ �wp w &i ° O w�p m a`¢-' �¢ owe c t¢ ¢ V) cn 3 ¢ �_vi o ¢ Z ¢ w _z z I p p J N Z rY U W JCD w0 Z p O o L) J N¢o rr u'> _¢ w z '�' ¢ ¢ Z(n ¢ CJ U U' C1 ¢ �� J J F U d 3�Z ��� wz w CZa Q zoo m g� �z s o J w w W N�Of(n w F z c� w L ��oo =0� �� M w w W o r w J x W r¢ z z w ¢ ¢ IW-*--E W ¢(i1 U F Z fn �p (r p cn �Z= O ¢Z Z O W F (� J In Z Z ¢F cn o ¢CD c� � cn w rl IJ I W W _J hoc, cli r5 'e Li cn r- W m W 0 M (,/) Wdto�� `•� . -• ; �_ to •� .r _; .x � ,, �� r � �' � :r' 1 :'o C' : �,� .� �:, ;� �: s�t - — 9060-t�*OOf'f--f'fOQS'9•:1•'HY d3 N0 ��Q 2rA, VIMPor ss�onldl�ls b a XI90rZ3 - o6 X09 Od 1=31 CNV LHGIU 6;UI3H5 1Nad1(10 JN/JN/JN3 313d77MN �133NION3 I'13d1d MN SWb`I'1'11M yr 4A — -- :. 0 zb 0 w Q U Z W O O W LLJ I < Ww Fo (A a_ O:D =W O W mm =pz Y p p Q �m� Y W o IL �w� =f..,z ~ Z z O D w Q(If w x I . O J .� \Y a Q LI ,LLJ IJ 0 J Vl o� J Cf V zw 0 �o wN W J v=i� w ww Qm V) �. �J wp N� a QO r W O o o(l) Q W I O¢^ p Q o0 X"�n Xm fD O n W d NX 17 W � f� X m Y X m LJ I\ N i=-.~.v N D - 0 O Ln W W � U IFIE J o (n i W LLI Z d 2 J I- Om; WNn�� W z� LLJ cc W = c� IJJ rn 0�w J X W iq z'p Cl- W mULna- cilia w ci 0 73 I e[96—#or—£'OS Xb'� xscra rvois»I-ttiv 5060—P,Of—fO� =Hd aK ZA Mp GO 11C x S0CZ6 IV 068X0837 d a ;JN/ OIVAY33N/ON3 3L13�'Yy-nm NO Il�fl�3'13 N'd�V -L't3H5 1N3Wd I P1t�3 �WlZcild MN SAVI-Ill, N[n 2 v e �D . ti /n zYL T N II 0 1 O \_ o Q V) N W Z Lj H w X I W J W W F LLJ Q �I O L21 LL_I zv�^ pwz F W m 1 QF- �U' Y wz 1 u0im L a Ofkf LL W x J F- H X O W W V (O Q r7F W �W W O a NQ UI � U� //ff (n Z m W W clf 1 / W V) ` O J =U in a w w _O O U V) W V) Ir W D � F � U U O J W W LL, V) Cr F'°'00W V) W X�mw Wm Loa- CL W O j3� Cn cl-aCnL� z196-4.Of-f'O9 -XV3 zuob HoivNi r 5060-#Of—£O5 •Hd S0f Z6 N0 06d0X08 O d �N/ JNIb33N/Oef 6 XOSb''Od NOI.LV \313 1NOJ� J31-3H5 LNMWdlrlV� ¢ b'��NIJN� 3Nl'l3dld MN SWb`ITTIM J[9,i U • ='1. UI} W �> �Z0 �ZZ \ . X O Q W N Q W N W w 0 tOSO r r y,-•1-� r,0 NU)S NU)S v z I O U w / .. _ In w Z J W� U) <0 M m W C U Zof 7 .L I ~W o .I N m O N Qfy, N bi o U \ I Q Ir m ' I— Ul U X w F.- W V Q X ! U vUl U N w M Z X i. � Y M U 0 W x W Li LLI 7 ` �} I Z �_ 1 m W W o w z 5 x 1 :DWJw (Unm _ < YW0 F- 00Y Ua7 ¢ , Q Z W O W¢ 0}S 0 Q Q W U) 0 3 ¢ c�x�_ F- W - mm w J X M U O V)0 W Zv U W 1 M x w m N Z C V!L M W U 7 > X N U a W S �W O I N XQ} O F- U0 Q(� f Nm.~iva �fnm ♦ 0m Q 1 U X m U) O I N 1 �Z W FS-O W z .9_,L O ui ul H Y m w .MQ- W Z J_M¢ � W W cn O I IL m W (n m C v D � U H D U Of V)J W w N In Ld CT, O W (n W X O7 W � wm� EL cl-- W d <r CJO (J7 I a cn In 3 .:r�-1 �� I 1 5060—*O fO9 XNd UN 2A Crlro*lz� p x 9OfY6 NO934YO W37b'S 2TO6 X0S 0 d S,7Ib13a N01103NN00 a131'73H5 1N�AcilnVa 7Nl 0N/,133N/9N3 3L13lNb'77M i R _73N/DNS 3NI-Mcild MN SW'Vil-liM o �P Q a Cn ` ° I¢ Q �� a 1 WCD �- L U LU Q L � co •9L Vld W Om Q V/ O O m Q X O =X7 m W N x� L_ X N Ow < Q j F O w V1 p w J I m O w m LU w Q r'I m w ~aFn � r� � �y-� oo x� LJ w W az y W tr�G L c= _z ^I v \ U� o Cl (O� 1- � � N� W o xW w 01) 1~. Ja Z N oV zDJ ZOC4 U ❑ % W�zVz/ W `" aW FK CZ CL LLLLLI 10 15 Q Q LL_oIr 0W Qa� V m W U Z V) X Lj CD U1YOU � mw GO XO Qw " WN mLIJ / Z Q \ � NH.�i 1v�0 V' 1 1 N w x w D > I � D J U W rtr-,L W wcy�rn� H—* oO W V I X0 in W Wm0L011 w OM3i =D aOUO3: Lcn 0- �� :; i _ � 'i - -. - - j BEACH. VERNON ' • PARCEL #: 31051200100400 55, r 1took dla— �� RP7arH VFRNON^• i r 20 1 PARCEL #: 31051200100500 ` (STING EASEMENT WORK'AREA: 8.9.72 S.F- 0 261 ac PORARY EXTRA WORK AREA: , 1'5 S.F. 0.321 ac. P. CP a� NORTHWEST PIPELINE CORP y PARCEL # 31051200100700 EXISTING EASEMENT WORK AREA: 92W W 2,551,279 S.F. 0 058 ac NORTHWEST PIPELINE CORP PARCEL #: 31 n51200100800 EXISTING EASEMENT WORK AREA: "CASCADE NATURAL GAS CORP = 1,495.19 S.F 0.034 ac_ PARCEL #: 105 1200 100 ARIL INGI N_'WA, INGTON METER STATION 1 40 4 LEGEND } Pipeline Centerline '" M• r^ r^ � �, - Permanent Right—of—Way ♦ e i = Access Road Property Line ' Temporary Extra Work Area ' I z NOTE: s Q 3-5_ 1 New Permanent Work Area BECAUSE THIS EXHIBIT IS NOT BASED ON A PROPERTY SURVEY, THE ACTUAL RIGHT—OF—WA r ,, Existing Easement Work Area AND WORKSPACE AREAS MAY VARY SLIGHTLY i i, FROM WHAT IS SHOWN. 1 NORTHWEST PIPELINE, LLC I 1 r• ••1 71 1• •rARLINGTON LOCATION MAP F - FP , . . �' 1• .• 1 1 1 1 1 1 I I O 1 + 1 1 11 1 `IAC Willamette Engineering, Inc. PO Box 9032, Salem, Or 97305 Ph (503) 304-0905 Fax (503) 304-9512 STRUCTURAL CALCULATIONS FOR STEEL SHELTER AND ANCHORAGE WILLIAMS NW PIPELINE EQUIPMENT SHELTER LOCATED AT 21403 92ND AVE NE ARLINGTON, WA 98223 THESE SHEETS ARE VOID IF SEAL IS NOT RED t.� PHo ��aF WA `"9y �z o �r NAL upAas APRL & SIGNATURE IS NOT ORIGINAL 14 PAGES NOT COUNTING COVER SHEET ""LIMITATIONS"" NO RESPONSIBILITY AND/OR LIABILITY IS ASSUMED BY, OR IS TO BE ASSIGNED TO THE ENGINEER FOR ITEMS BEYOND THAT SHOWN ON THESE SHEETS. JOB NO. 2019-44 MAY 21,2019 PREPARED BY GERALD P. HORNER,PE Received JUL 16 2019 YLa --,7ULp9 WILLIAMS NW PIPELINE iELTER f 21403 92ND AVE NE PC, ARLINGTON,WA 98223 J ASCE 7-10 WIND DESIGN FOR MAIN FORCE RESISTING SYSTEM _ 120 MPH ULTIMATE WIND SPEED PER OSSC FIGURE 1609A ^ CONVERTED TO ASD DESIGN PER OSSC TABLE 1609.3.1 ROOF- 15 DEGREES -BASIC WIND SPEED- 120 MPH EXPOSURE- "C" R 1 5 v r A�l! /. u _ i BUILDING FEATURES `. •� ' "`uV - HEIGHT 10. 1 LENGTH 20' WIDTH l4' ZONE LOAD CASE PS 30 PSF ASD-PSF I "C" PNET-PSF A 2 28.7 22.2425 1.00 1.41 31.36, B 2 -9.5 -7.3625 1.00 1.41 -10.38 C 2 19.1 14.8025 1.00 1.41 20.87 D 2 -5.4 -4.185 1.00 1.41 -5.901 E 2 -27.4 -21.235 1.00 1.41 -29.94 F 2 -17.9 -13.8725 1.00 1.41 -19.56. G 2 -19.1 -14,8025 1.00 1.41 -20.87 H 2 -13.7 -10.6175 1.00 1.41 -14.97 OVERHANG E 2 38.41 29.761 1.00 1.41 41.96 OVERHANG G 2 -30.1 -23.3275 1.00 1.41 -32.89 ZONE 5; "a" DIMENSIONS LONG DIMENSION HORIZONTAL 0.1%20') +2' HEIGHT 0.4{10')= 4 r USE 3' SHORT DIMENSION -HORIZONTAL 0.1014')= 1.4' HEIGHT 0.4(10')= 4' - --- `_ USE � Y_ DESIGN CRITERIA SEISMIC-SIDS =0.7-1 SOIL- 1,500 PSF,Ca=0.36 SNOW- PSF 25 GROUND, t-,, ROOF DEAD LOAD-6 PSF WALL DEAD INTERIOR-6 PSF _ WALL DEAD EXTERIOR-6 PSF T . . STRUCTURAL FORMULAS D+ F IBC 16-8 D+H + F+L +T IBC16-9 D+H + F+(L6rSorR) I13C16-10 _ D+H +F+0.75'(L+T)+0.75'(LorSorR) IBC16-11 D+H+F+0.75 Lwor0.7E) IBC16-12 D+H + F+0.75(W or 0.7E)+0.75L+0.75(L or S or R) IBC 16-13 _ 0.61D+W+H IBC16-14 0.6D+0,7E+H IBC 16-14 WILLAMETTE ENGINEERING, INC. PROJECT WILLIAMS NW PIPELINEJ❑B N❑ 2019-44 SALEM, OREGON SHELTER STRUCTURAL CALCS _ DATE 05-07-19 PHA 503-304-0905, FAX, 503-304-9512 BY JERRY HORNER PAGE OF VV;Il�ams NVIJ Pipel+ne 21403 92nd Ave NE Arlington v'vH Date and Ttme 4,/2.8i2019 8 31 12 PM MCE Parameters - Conterminous 48 States Zip Code 98223 Central Latitude = 48 207031 Central Longitude = 121 953365 MCE MAP VALUES Short Period Map Value - Ss = 110.11% g 1.0 sec Period Map Value - S 1 = 30.9,�;, g RESIDENTIAL DESIGN INFORMATION Short Period Map Value - Ss = 110 11/6 g Soil Factor for Site Class D - Fa = 1 06 - Residential Site Value = 2i3 x Fa x Ss 277 8% g 1 Residential Seismic De<,gn ,we-we y I � WILLAMETTE ENGINEERING, INC. PROJECT WILLIAMS NW PIPELINEJOB NO 2019_44 SALEM, OREGON SHELTER STRUCTURAL CALCS DATE 05-07-19 PHa 503-304-0905, FAX, 503-304-9512 BY JERRY HORNER PAGE O F _u 4• D- 4'-0' r (Typ (T1P 1J :xi GtJ/Nth ��2- FltffN� •.��a,•: � ___-_ _ 63, '26 4)CZo •8 7,,PfA = L-6 60 87 0 �p �j 3H T AND LEFT SIDE ELEVATION 6W 2_ 0 PSG 5(0 E MULL/a N 7,S�T,4LL a P UDR 20 ROCF) PANE �J s Z a, �7 PA'TERN AT ROCF qh0 SIL1tj Ak �'/F�.r�'-_ ..1. •��� y.l4 OF 0i2 A TEK SCREWS J Sr �f 6 Z V CJ 1 Yt ONE SIDE ONLY TTYP.) l a '--PEAK -. . ./ •'�/� R /�[ 3"X.-I]'X A.RISG fLBF -7EE f L ���� f` �(/V/ ��VX3'C1�GA TUBE q •� ' r {J RA: R I ,--2"x3'af;(; 0A 'OBE — C� 7" q 5HOEOPEN 26CR A MET AI le LV l/�•ej U /J- l € 3 IZONTAL 1 P�� 2"X3"XOp72" STEEL S` 'I 1' I �,(,-r ' 6G F M 4 h bc-lz v i` TUBE SIDE POST(Am)) J J y� �I}// '! T\W�� {, p� _N{.-�'.'. TUBE BOTH OST(A �+ [ /, (� IS Tp fi-OLE> La/ND 3/3 `OAKc- I P5F CONCRETE MUNDAfION SLAB DESIGN BY OTHERS 7 Z (6•THK MIN i - Mi � tC �Z1 DS r—) FRONT ELEVATION � F0 = 56 R 5 33� 5eo PS-1 WILLAMETTE ENGINEERING, INC. PROJECT WILLIAMS NW PIPELINEJOB NO 2019-44 SALEM, OREGON SHELTER STRUCTURAL CALCS DATE 05-07-19 PH, 503-304-0905, FAX, 503-304-9512 BY JERRY HURNER PAGE OF may_ Y z S79 ! = 3 ` C `/.s�C 34 3(a Ps�� f 3.�`��rs`)C�.g�PSF� `--)sz LB L 6 U 5& 66 O Zo' o F 7!o Gfl Sfl �f?"I-1 cYG '?S2 L0106 `= 3 �9 RL F Sl-IEAT/� �A OpA& If Y� Z 1& PL > 3 � PLF e K d Ill L1 5 F D f2- (3 vE►—� t,/C� 9 Psq 0 07')�� � = 13 a r �s u PL 1 F r L a N a, wr FRS Mj5- 8 - 1602 -cps r2 S 1 3'.5 k 51: d pc\.A www.hiltims Profis Anchor 2.6.3 Company: Willamette Engineering,Inc. Page: 1 Specifier: Gerald Horner Project: Williams NW Pipeline Address: PO Box 9032 Sub-Project I Pos.No.: One 1/2"Anchor Phone I Fax: 503-304-0905 1 503-304-9512 Date: 5/8/2019 E-Mail: jer.willengr@juno.com Specifier's comments:Piping Shelter Concrete Connection,21403 92nd Ave NE,Arlingon,WA 1 Input data 44;".— Anchor type and diameter: KWIK HUS-EZ(KH-FZ)1/2(3) 4� L i Effective embedment depth: hef=2.160 in.,hnum=3.000 in. Material: Carbon Steel Evaluation Service Report: ESR-3027 Issued I Valid: 12/1/2015 1 12/1/2017 Proof: Design method ACI 318/AC193 Stand-off installation: eb=0.000 in.(no stand-off);t=0.250 in. Anchor plate: Ix x ly x t=4.000 in x 8.000 in.x 0.250 in.;(Recommended plate thickness:not calculated Profile: Rectangular plates and bars(AISC);(L x W x T)=0.250 in.x 0.188 in.x 0.000 in. Base material: cracked concrete,3000,f�=3000 psi;h=6.000 in. Reinforcement: tension:condition B,shear:condition B;no supplemental splitting reinforcement present edge reinforcement:none or<No.4 bar Seismic loads(cat.C,D,E,or F) no Geometry[in.]&Loading[Ib,in.lb] Z �1 �o T. . Y Z 5 F ` \ 0.25 Ir- CO GO Q�w X Input data and results must be checked for agreement with the existing condilions and for plausibility! PROFIS Anchor(c)2003-2009 Hilli AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan www.hilti.us Profis Anchor 2.6.3 Company: Willamette Engineering, Inc. Page: 2 Specifier: Gerald Horner Project: Williams NW Pipeline Address: PO Box 9032 Sub-Project I Pos No. One 1/2"Anchor Phone I Fax: 503-304-0905 1 503-304-9512 Date: 5/8/2019 E-Mail: jer.willengr@juno.com 2 Load case/Resulting anchor forces y Load case:Design loads Anchor reactions fib] Tension force:(+Tension,-Compression) Anchor Tension force Shear force Shear force x Shear force y 1 1549 320 313 68 max.concrete compressive strain: N1 max concrete compressive stress: -[psi] Te o x resulting tension force in(x/y)=(0.000/0.000): 1549[lb] resulting compression force in(x/y)=(0.000/0.000):0[lb] 3 Tension load Load N a[lb] Capacity+N„[lb] Utilization N„s/^ Status Steel Strength' 1549 11778 14 UK Pullout Strength' N/A N/A N/A N/A Concrete Breakout Strength— 1549 1921 81 OK "anchor having the highest loading —anchor group(anchors in tension) 3.1 Steel Strength Nsa =ESR value refer to[CC-ES ESR-3027 4t Nsa z Nua ACI 318-08 Eq.(D-1) Variables Ase,N(in.2] fuwa[psi]_ 0.16 112540 Calculations Nsa[lb] 18120 Results Nsa[lb] steel N„fib) Nua fib] 18120 0.650 11778 1549 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilli AG,Schaan www.hilti.us Profis Anchor 2.6.3 Company: Willamette Engineering, Inc. Page: 3 Specifier: Gerald Horner Project: Williams NW Pipeline Address: PO Box 9032 Sub-Project I Pos.No.. One 1/2"Anchor Phone I Fax: 503-304-0905 1 503-304-9512 Date: 5/8/2019 E-Mail: jer.willengr@juno.com 3.2 Concrete Breakout Strength N =(A°") - - cb ANci) lVed,N IVc,N lVcp,N Nb ACI 31808 E q•(D4) Nce>N18 ACI 318-08 Eq.(D-1) AN, see ACI 318-08,Part D.5.2.1,Fig.RD.5.2.1(b) ANco =9 hef ACI 318-08 Eq_(D-6) ,V 1 ec,N = i +2 eN 5 1.0 ACI 318-08 Eq.(D-9) 3'h,, IVed,N =0.7+0.3(C 5h)5 1.0 ACI 318-08 Eq (D-11) el tVcp,N =MAX(c°""' 1'5hB1)5 1_0 ACI 318-08 Eq.(D-13) C= ' cec Nb =k.X 4f.-hafs ACI 318-08 Eq.(D-7) Variables hef[in.] ec1,14[in.] ec2,N[in] c.,min[in.] IVc,N 2.160 .00 0.000 7.000 1,000 ca.[in.] kc X f.[psi] 3.750 17 1 3 0 Calculations ANc(in•21 ANco[In_21 IV cl,N %Vec2,N WV d.N 1V ,N Nb[lb] 41.99 4199 1.000 1.000 1.000 00 2956 Results Ncb[lb] wconcrete NM(lb] Nua 11b] 2956 0.650 1921 1549 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan L , J �J\ I -a Milli www.hilti.us Profis Anchor 2.6.3 Company: Willamette Engineering, Inc. Page: 4 Specifier: Gerald Horner Project: Williams NW Pipeline Address: PO Box 9032 Sub-Project I Pos,No.: One 1/2"Anchor Phone I Fax: 503-304-0905 1 503-304-9512 Date: 5/8/2019 E-Mail: jer willengr@juno.com 4 Shear load Load V,,,[lb] Capacity+V„[Ib] Utilization V_/+Vn Status Steel Strength' 320 5547 6 OK Steel failure(with lever arm)" N/A N/A N/A N/A Pryout Strength— 320 2069 16 OK Concrete edge failure in direction x+"" 320 2670 12 OK "anchor having the highest loading '"anchor group(relevant anchors) 4.1 Steel Strength Vsa =ESR value refer to ICC-ES ESR-3027 0 Vsleel Z Vua ACI 318-08 Eq.(D-2) Variables Ase,v[in.2] futa[psi] 0.16 112540 Calculations Vs.[lb] 9245 Results Vsa[lb] 0slee1 Vs.[lb] Vua[lb] 9245 0.600 5547 320 4.2 Pryolut Strength Vcp —^cp[(ANccO)4led,N Wc,N wcp.N Nib ACI 318-08 Eq.(D-30) Vcp a Vua ACI 318-08 Eq.(D-2) AN. see ACI 318-08,Part D.5.2.1,Fig,RD.5.2.1(b) AN.0 =9 hef ACI 318-08 Eq.(D-6) 1 ,sec N = I +2 eN 5 1.0 ACI 318-08 Eq.(D-9) 3 In iVed,N=0.7+0.3 (1 5h f/51.0 ACI 318-08 Eq.(D-11) tycp,N =MAX(o., 1.5h.)5 1.0 ACI 318-08 Eq.(D-13) Cac ' Cnc Nb =kc x 4-c hBi5 ACI 318-08 Eq.(D-7) Variables 14P hef[in.] ec1.N[in.] ea.N[in.] c,.a,.,[in.] 1 2.160 0,000 0.000 7.000 lVc.N cac[in.] kc X fc[psi] 1.000 3.750 17 1 3000 Calculations ANc[in•2] ANO[irl 1et1,N g1eo2,N %INad.N ,Itap.N Nb[lb] 1. 9 41.99 i. 1,000 1. 00 1000 2956 Results Vcp(lb] 0concrete +V,p(lb] Vua[1b] 2956 0.700 2069 320 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan www.hilti.us Profis Anchor 2.6.3 Company: Willamette Engineering,Inc. Page: 5 Specifier: Gerald Horner Project: Williams NW Pipeline Address: PO Box 9032 Sub-Project I Pos No.: One 1/2"Anchor Phone I Fax: 503-304-0905 1 503-304-9512 Date: 5/8/2019 E-Mail: jer.willengr@juno.com 4.3 Concrete edge failure in direction x+ _(A„` V`b — \A,/uo IVed,V tVc,V kVh,V 4/parallel,V Vb ACI 318-08 Eq.(D-21) $1 Vcb>Vua ACI 318-08 Eq.(D-2) Avc see ACI 318-08,Part D.6.2.1,Fig,RD.6.2.1(b) Avco =4.5 e1 ACI 318-08 Eq.(D-23) ,Vec,V = ( 11 e 5 1 0 ACI 318-08 Eq.(D-26) 3c„ Yed,V =0.7+0.3(1 52 )5 1.0 ACI 318-08 Eq.(D-28) kVh V = 1 hc"a 1 0 ACI 318 08 Eq.(D-29) a 02 Vb =(7(da) �) C. ACI 318-08 Eq.(D-24) Variables cal[in.] cat[in.] e&[in-] k .v ha[in.] 7.000 7.000 0.000 1.uuu 6.000 le[in.] X da[in.] f.[psi] 1vpara11e1,V 2-160 1.000 0 500 Calculations Av.[in?] Avco[in.zl 00 tva4v wb.V Vb[lb] 105.00 220.50 1 000 0.900 1.323 6728 Results Vcb[lb] concrete Vcb[lb] Vue[lb] 3814 0.700 2670 320 5 Combined tension and shear loads Llf, 11v ` Utilization[;Nv[%] Status 0 806 0 155 5/3 75 OK pNV=Pil+PV<=1 6 Warnings • Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered.The anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the loading! Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies when supplementary reinforcement is used.The 0 factor is increased for non-steel Design Strengths except Pullout Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength,Refer to your local standard. • Refer to the manufacturer's product literature for cleaning and installation instructions. • Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard! Fastening meets the design criteria! Input data and results must be checked for agreement with the existing conditions and for plausibility! T PROFIS Anchor(c)2003-2009 Hild AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan r C e, (D ok I www.hilti.us Profis Anchor 2.6.3 Company: Willamette Engineering,Inc. Page: 6 Specifier: Gerald Horner Project: Williams NW Pipeline Address: PO Box 9032 Sub-Project I Pos.No One 1/2"Anchor Phone I Fax: 503-304-0905 1 503-304-9512 Date: 5/8/2019 E-Mail: jer.willengr@juno.com 7 Installation data Anchor plate,steel:- Anchor type and diameter:KWIK HUS-EZ(KH-EZ)1/2(3) Profile:Rectangular plates and bars(AISC);0.250 x 0.188 x 0.000 in. Installation torque:540.001 in.lb Hole diameter in the fixture:df=0.625 in. Hole diameter in the base material:0.500 in. Plate thickness(input):0.250 in. Hole depth in the base material:3.375 in. Recommended plate thickness:not calculated Minimum thickness of the base material:4.750 in. Drilling method:Hammer drilled Cleaning:Manual cleaning of the drilled hole according to instructions for use is required. 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer Manual blow-out pump Torque wrench • Properly sized drill bit Y 2.000 2.000 0 0 0. o v v X 0 0 0 0 0 0 v v 2.000 2.000 Coordinates Anchor in. Anchor X y c_„ c.„ c_„ c,y 1 0.000 0.000 12.000 7-000 7. 1 .000 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan pilot ICC EVALUATION Ak�� SERVICE Most Widely Acceptedanci.TrUStCd ICC-ES Evaluation Report ESR-3294 Reissued February 1, 2014 This report is subject to renewal April 1, 2016, www.icc-es.org 1 (800) 423-6587 J (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 05 00 00—METALS 3.2 Standard Drill Screws: Section:05 05 23--Metal Fastenings 3.2.1 EDC450 (Type 1): The EDC450 screw has coarse threads and an indented high hex washer head with an DIVISION: 06 00 00—WOOD, PLASTICS AND undercut. This screw complies with the thread design, COMPOSITES material specifications and performance requirements of Section:06 05 23--Wood, Plastics and Composite ASTM C1513. Fastenings 3.2.2 EDB446, EDB486, EDB541, EDB571 (Type 2): REPORT HOLDER: These screws have coarse threads and an indented high hex washer head. These screws comply with ASTM ELCO CONSTRUCTION PRODUCTS/ C1513. an INFASTECH COMPANY 3.2.3 EDC745 (Type 3): The EDC745 screw has coarse 1302 KERR DRIVE threads and an indented hex washer head. This screw DECORAH,IOWA 52101 complies with ASTM C1513. (800)435-7213 3.2.4 EDB741, EDB761, EDB782, ED13801, EDB821, www.alcoconstruction.com EDB830, EDB840, EDB845 (Type 4) and EDA790 (Type infoElco rifastech.corn 4A): These screws have coarse threads and an indented hex washer head.The screws comply with ASTM C1513. EVALUATION SUBJECT: 3.2.5 EDC930 (Type 5): The EDC930 screw has coarse threads and an indented hex washer head which is smaller ELCO CASE-HARDENED SELF-DRILLING TAPPING than that required by ASME 818.6.4. The screw complies SCREWS with the thread design, material specifications and performance requirements of ASTM C1513. 1.0 EVALUATION SCOPE 3.2.6 EDB936, EDB946, EDB956, EDB961, EDB971, Compliance with the following codes: EDB976, EDB981, EDB983 (Type 6): These screws have t 2012,2009 and 2006 International Building Code(IBC) coarse threads and an indented hex washer head. These e screws comply with ASTM C1513. a 2012 and 2009 International Residential Code (IRC) 3.3 Drill Screws with Extended Drilling Capacity: Property evaluated: 3.3.1 EDC801, EDC816 (Type 7): These screws have Structural fine threads and an indented hex washer head. The 2.0 USES spacing of the lead threads is greater than the spacing of the remainder of the threads. These screws comply with Elco case-hardened self-drilling tapping screws are used to ASTM C1513. connect cold-formed steel members together, to connect 3.3.2 ECC720, ECC740, ECC750 (Type 8): These cold-formed steel to hot-rolled steel plates and to connect screws have fine threads and an indented hex washer wood structural panel sheathing to cold-formed steel. The head. The threads nearest the drilling point are slightly screws are used to resist shear and tension loads in deformed and the manufacturer describes the thread engineered connections and are used in connections design as Round Body Taptite,These screws comply with prescribed by the code for steel-to-steel and wood-to-steel the material specifications and performance requirements connections. of ASTM C1513. 3.0 DESCRIPTION 3.4 Architectural Roof Clip Fasteners [ED0450, 3.1 General: ED0460,ED0470(Type 9)]: The Elco screws are self-drilling tapping screws formed The fasteners are coarse thread screws with pancake-style from carbon steel wire conforming to ASTM F2282, Grade heads.These screws comply with ASTM C1513. 1018 - 1022, and case-hardened to 50 to 56 HRC. The 3.5 Drilite Drill Screws: screws are coated with a pryrielary corrosion-resistant 3.5.1 EDT602 (Type 10): The EDT602 screw has fine coating identified as Stalgard . Table 1 provides screw threads and a Phillips wafer head. Between the threads descriptions including type, size, threads per inch (tpi), and the drill point, the screw has a portion of smooth shank nominal diameter, head style, head diameter, point type, with two projecting wings. The EDT602 screw complies length, drilling capacity, length of load bearing area, and with the thread design, material specifications and coating Information. performance requirements of ASTM C1513. WC-F_S Evaluation Reports ar a not to he c•onsuved as rep,eseuring aesthetics of ant-other attributes nor specifically addressed,nor are then to be construed MM as an rndorsernene of the.ruhirce of-the reporr err a recommendation f lr irs use [here is no warranty,Ay ICC Evahmtion Service LI C_express or implied,as (�.f r�'}•7i�� to ane finding or other mnt(er in fhis report of ay ro anyprnduct envered hp the-pni ,wry Copyright*2014 Page 1 of B ESR-3294 I Most Widely Accepted and Trusted `-;-y J ` � � r Page'!)_ d# I y TABLE 2-ELCO SELF-DRILLING SCREWS SHEAR AND TENSION FASTENER STRENGTH(Ibf) DESIGNATION NOMINAL STRENGTH ALLOWABLE STRENGTH(ASD) DESIGN STRENGTH (LRFD) Shear:P. Tension:P, I Shear:P./o I ension:Pd l Shear:(OP. Tension:(PP, STANDARD DRILL SCREWS #10-16 1679 2670 560 890 840 1335 #12-14 2032 3211 667 1070 1016 1606 tl4-14 2559 5021 853 1674 1280 2511 EXTENDED DRILLING CAPACITY SCREWS #12-24 2283 4034 1 761 1 1345 1142 2017 ARCHITECTURAL ROOF CLIP FASTENERS #10-16 1560 2326 520 775 780 1163 For SI:1 inch=25.4 mm, 1 Ibf=4.4 N. TABLE 3A-ALLOWABLE(ASD)SHEAR(BEARING)CAPACITY OF SCREW CONNECTIONS'a'',Ibf THICKNESS THICKNESS OF STEEL NOT IN CONTACT WITH SCREW HEAD(in.) �N(0MINAL OF STEEL IN DESIGNATION DIAMETER, CONTACT (In) WITH 0.030 0.036 0.048 0.060 0.075 0.090 0.125 0.188 0.250 0.375 SCREW --- HEAD STANDARD DRILL SCREWS 0.030 143 193 231 231 231 231 231 0.036 143 188 277 277 277 277 277 - - #10-16 0,190 0.048 143 188 289 369 369 369 369 _ 0.060 143 188 289 404 462 462 - - 0.075 143 188 289 404 564 577 0.090 143 188 289 404 564 693 0.030 150 205 255 255 255 255 255 255 - 0.036 150 197 304 306 306 306 306 - 0.048 150 197 04 408 408 408 408 #12-14 0.216 0.060 150 197 304 424 510 510 510 - - 0.075 150 197 304 424 593 638 638 - - 0.090 150 197 304 424 593 765 765 - - 0.125 150 197 304 424 593 765 - - 0.030 160 222 292 292 292 292 292 292 0.036 160 211 325 350 350 350 350 0.048 160 211 325 454 467 467 467 V.-14 0.250 0.060 160 211 325 454 583 583 583 - - 0.075 160 211 325 454 634 729 729 - 0.090 160 211 325 454 634 833 875 0. 225 160 211 325 454 634 833 EXTENDED DRILLING CAPACITY SCREWS 0,036 404 370 400 #12-24 0.216 0.060 829 630 677 0.090 588 E[E643 667 ARCHITECTURAL ROOF CLIP FASTENERS 0.030 232 286 350 335 #10-16 0,'190 0.036 343 423 484 472 For SI: 1 inch=25.4 mm, 1 Ibf=4.4 N. 1 ksi=6.89 MPa. "'See notes following cable 3& Premier Steel StrLlCtUres F3 E3 Roof and Wall Panel I EXPOSEDO• COMMERCIAL FASTENERS 36" COVERAGE :12 OPEN FRAMING PANEL DESCRIPTION — Applications: industrial, Commercial, and Agricultural — Limited 40-year warranty paint Finishes 26 ga: 10 standard SMP Colors and Gaivalume®R, Finishes 24 ga: 10 standard PVDF colors Corrosion Protection on Substrate: -AZ-SO (ASTM A792) for painted Gaivalume(Rj -AZ-55 (ASTM A792) for unpainted, acrylic coated, GaivalumeL G-60 (ASTM A653) for painted Galvanized - G-90 (A5TNI A653) for PVDF painter! 24 gauge Sheet lengths: 1` to 50'-0" in one inch increments Polycarbonate and fiberglass light panels available in PBR profile - For color availability, cool roof specs, and other panel info, please see our website: www.metallionindfistries.com ILL. TESTING DATA U - UL 2218 Impact Resistance UL 790, 263 Fire Resistance UL 580 Uplift Resistance PSR Allowable Loads(—Ssft-'] per soana - �_. Boa Lead '/oe 2 5 3' 33 4 LL'ind;aad'.,Upluc) � 2S? 164 !'�4 33 64 50 30 33 '3 �4 Live Load Deflection 295 166 107 78 57 42 33 26 21 18 15 bVind Load(Uplift) — jO 132 94 69 » 42 34 29 1 20 r' oub1 Live Load Deflection 575 363 134 99 76 60 48 37 30 24 20 Wind Load(Uplift) 233 150 �15 36 66 53 13 36 30 25 22 Live Load Deflection 448 Z85_ 146 108 84 67 53 42 34 28 23 26 gauge has 0184"min Substrate Thickness,80 KS'i Tensile,and'Neighs about 9 Us Per Sq,Ft Ga an ),Dad Tgpe 21 2 5' 3' 3 5' 4 4.5' 5' 5.1 h 5.5' Wind Load(Uplift) 234 196 135 98 75 60 48 39 34 27 24 Live Load Deflection 285 183 125 91 70 56 45 37 31 26 22 Dc bl_ 'Find Load(Uplift) 268 178 130 96 74 59 48 39 33 29 24 Live Load Deflection 274 1 180 125 92 71 57 46 38 31 27 23 bNind Load(Uplift) 321 213 49 85 58 51 46 38 1 32 23 pe Live Load Deflection 334 222 155 115 89 71 57 47 40 34 29 24 gauge has 0236' min Subst-ace Thickness,50'KSI Tensile(UL) Panei Width:36",AS T NA A653 1 Dei!ecdea !cads are based on a:naaimum deflection ration of Li180 of span 2 '_Pads are averages hom similar pracwczs with design ioads meeting AI51 specifications Home Elspafiol Contact Search L&ISEARCH Lab or & Industries Safety&Health o Claims&Insurance 19 Workplace • 19 Washington State Department of Labor & Industries J T I COMMERCIAL SERVICES LLC Owner or tradesperson 1006 CENTRAL RD Principals EVERSON,WA 98247 HUIZENGA,TED ALLEN,PARTNER/MEMBER 360-398-2670 Doing business as WHATCOM County J T I COMMERCIAL SERVICES LLC WA UBI No. Business type 602 392"0 Limited Liability Company Certifications & Endorsements License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. JTICOT1955DG Effective—expiration 03107/2005—03/31/2021 Bond CBIC $12,000.00 Bond account no. SF2797 Received by L&I Effective date 02/13/2009 02/12/2009 Expiration date Until Canceled Insurance Western National Assur Co $1,000,000.00 Policy no. CPP1067215 03 Received by L&I Effective date 12/04/2018 12/15/2015 Expiration date 12/15/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&1 Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts Help us improve may be recorded by other agencies. { � �• I I �: License Violations r—` No license violations during the previous 6 yt jeriod. Workers' comp Public Works Requirements Workplace safety and health I RESIDENTIAL PERMIT APPLICATION Department of Community & Economic Development � jNG,Cp City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR A NEW SINGLE-FAMILY, DUPLEX, TOWNHOUSE, ADDITION, DECK, OR ACCESSORY STRUCTURES. THIS APPLICATION MUST BE ACCOMPANIED BYTWO(2) SETS OF CONSTRUCTION DRAWINGS AND TWO(2) SETS OF STRUCTURAL CALCULATIONS. THE APPLICATION MUST ALSO INCLUDE THE PLUMBING SUBMITTAL AND THE MECHANICAL SUBMITTAL FORMS. THE ZONING VERIFICATION MAY BE SUBMITTED PRIOR. Project Address: 9111 Tveit RD, Arlington, WA 98223 Plat: NA ❑ Single-family ❑ Duplex ❑ Townhouse ❑ Addition W Accessory structure Proposed Area: 1"' Floor: 2"� Floor: Garage: Shelter Total SF: 280 Describe Proposal (include cross street): Replace existing 20ft x 14ft detached equipment shelter/canopy with new. Valuation: $2000.00 Owner: Northwest Pipeline LLC 22909 NE Redmond Fall City Road Redmond WA 98053 Address: City: State: Zip Code: Phone: 425-301-1068 Email: Clay.Gustaves@Wiilliams.com Applicant: Clay Gustaves 22909 NE Redmond Fall City Road Redmond WA 98053 Address: City: State: Zip Code: Phone: 425-301-1068 Email: Clay.Gustaves@Wlliams.com Contractor: Northwest Pipeline LLC 22909 NE Redmond Fall City Road Redmond WA 98053 Address: City: State: Zip Code: Phone: 425-301-1068 Email: Clay.Gustaves@Wlliams.com Contact Person: Clay Gustaves License Number:603 325 992 Expiration: 8/31/2019 6'16LP Page 1 of 3 RESIDENTIAL PERMIT APPLICATION ' Department of Community & Economic Development City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551 Plumbing Section (continue filling out K plumbing is involved) (Check all that apply and indicate the number of fixtures proposed) ❑ Bath/Shower Combo (4.0) x ❑ Sink (1.5) x ❑ Shower (2.0) x ❑ Lavatory (1.0) x ❑ Clothes Washer (4.0) x ❑ Water Closet (2.5) x ❑ Dishwasher (1.5) x ❑ Water Heater x ❑ Hose Bibb (2.5) x Water Heater Model # ❑ Other (list) x Plumbing Section Continued Proposed Water Piping Size: Proposed DWV Material: Proposed Piping Material: Proposed DWV Size: • All hose bibs required to be equipped with Atmospheric Vacuum Breakers per ASSE 1019 • All water supplies at 80psi or greater shall have Pressure Reducing Valves (PRV) 6/16LP Page 2 of 3 RESIDENTIAL PERMIT APPLICATION ' Department of Community & Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551 Mechanical Section (continue filling out if mechanical equipment is involved) Select proposed appliances: ❑ Furnace (80+) Model # AFUE ❑ Heat Pump Model # SEER HSPE ❑ AC Unit Model # SEER ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ Hydronic Piping ❑ Boiler ❑ Solid-Fuel Appliance ❑ PV System ❑ Fireplace Insert ❑ Outdoor BBQ ❑ Storage Tank ❑ Freestanding Stove ❑ Gas Piping ❑ Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Total BTU's of all Appliances: Distance from Meter to Furthest Appliance: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper combustion air and venting required for all appliances • A shut-off is required within 6 feet of all appliances Applicant Signature: Date: 07/12/2019 Print Applicants Name: Clay Gustaves 6/16LP Page 3 of 3 NOTICE TO PERMITEE AND/OR OWNER Cl PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY PfAPPROVED PERMIT#: 2=43 AM PM DATE: JOB ADDRESS: 014,93 Z A L/ YJ LOT#: PROJECT: QQIP A+OL TYPE OF INSPECTION: ;r-7y ,� � G271 I�IG� OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION OL 'I o �'oy2 THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE ' 0 PLANNING 0 CIVIL BUILDING CITY OF ARLINGTON '� r NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY 2fAPPROVED PERMIT#: � �� rAM�/PM DATE: ( 20 2 c ' JOB ADDRESS: LOT#: PROJECT: �bU TYPE OF INSPECTION: h 0J1 )(A,l 7` �Ylsl i'-�� ( :_p r• OTHER: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE / O PLANNING O CIVIL n BUILDING CITY OF ARLINGTON CITY ARLINGTON OF 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS:360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 91 it Tveit Rd. Permit#: 2668 Permit Expiration Date: Parcel#: 31051200100500 Valuation: 2000.00 OWNER APPLICANT CONTRACTOR BEACH VERNON Northwest Pipeline JTI Commercial Services,LLC 9111 TVEIT RD 22909 NE Redmond Fall City Rd 1006 Central Rd. ARLINGTON,WA 98223 Redmond,WA 98053 Everson,WA 98247 425-301-1068 360-815-0693 LIC:JTICOTI955DG EXP:03/31/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE. Residential Accessory Structure CODE YEAR: 2015 STORIES: I CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of,any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State.To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law,or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor.The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCl l0/IRCI l0. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Clay R. Gustaves 7/15/2020 Signature Print Namc Date Re eased By Date CONDITIONS Adhere to approved plans.Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 07/15/2020 Building Permit Fee $100.70 07/15/2020 Building Plan Review Fee $65.46 07/15/2020 Processing/Technology Fee $25.00 07/15/2020 State Building Code Surcharge Fee $6.50 07/15/2020 Credit Card Surcharge $5.93 Total Due: $203.59 Total Payment: $203.59 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon CITY ARLINGTON OF 18204 59th Avenue NE,Arlington,WA 98223 INSPECTIONS: 360-403-3417-Permit Center: 360-403-3551 BUILDING PERMIT 9111 Tveit Rd. Permit#: 2668 Permit Expiration Date: Parcel#: 31051200100500 Valuation: 2000.00 OWNER APPLICANT CONTRACTOR BEACH VERNON Northwest Pipeline JTI Commercial Services,LLC 9111 TVEIT RD 22909 NE Redmond Fall City Rd 1006 Central Rd. ARLINGTON,WA 98223 Redmond,WA 98053 Everson,WA 98247 425-301-1068 360-815-0693 LIC:JTICOT1955DG EXP:03/31/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Accessory Structure CODE YEAR: 2015 STORIES: 1 CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City,of any state or federal law,or of any order,proclamation,guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order,proclamation,guidance advice or decision of the Governor of this State,this permit shall not authorize such work and shall not be valid.The building official is authorized to prevent occupancy or use of a structure where in violation of this Code,any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order,proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,inaccurate or incomplete information,or in violation of any City ordinance,regulation or order,state or federal law,or any order,proclamation,guidance or decision of the Governor. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1l0/IRC1l0. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Re eased By ZDatef CONDITIONS Adhere to approved plans. Call for inspections. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS, SIDEWALKS,DRIVEWAYS, MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 07/15/2020 Building Permit Fee $100.70 07/15/2020 Building Plan Review Fee $65.46 07/15/2020 Processing/Technology Fee $25.00 07/15/2020 State Building Code Surcharge Fee $6.50 07/15/2020 Credit Card Surcharge $5.93 Total Due: $203.59 Total Payment: $203.59 Balance Due: $0.00 CALL FOR INSPECTIONS Call by 3:30 pm for next day inspection,allow 48 hours for Fire Inspections When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon 20'-2" (STEEL TUBE BASE RAIL) Z GENERAL NOTES: " " TYP. 2 x3 x0.072 171 z p STEEL TUBE 1. ALL WORK IS TO COMPLY WITH THE LATEST ADOPTED VERSION OF THE BASE PLATE NP. 51 STATE OF WASHINGTON BUILDING CODE AND ANY APPLICABLE STATE, SI (TYP. SIDES) tO W �Lr)� COUNTY OR LOCAL JURISDICTION. �3-(TYP.) 3 2. THE CONTRACTOR IS RESPONSIBLE TO CHECK THE PLANS AND IS TO WpCap► ) NOTIFY THE ENGINEER OF ANY ERRORS OR OMISSIONS PRIOR TO THE W W�L I START OF CONSTRUCTION. 18 KNEE BRACE AT (4) INTERIOR ,O� FRAMES(TYP. BOTH Qm�ln 3. WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED i^- SIDES) DIMENSIONS. DO NOT SCALE THE DRAWINGS. ���'K 4. RISK FACTOR: CATEGORY 3 v 0 5. DESIGN LOADS: GROUND (LIVE LOAD) (SNOW) 25PSF, I=1.1 i WIND - 120MPH ULTIMATE SPEED, EXPOSURE "C", 1=1.0 T 6. SEISMIC: Sds = 0.778; I =1.25 FOUNDATION IL GENERAL NOTES: 3" T"P EDGE lu 1. FOOTINGS ARE TO BEAR ON UNDISTURBED LEVEL SOIL DEVOID OF ANY ORGANIC MATERIAL AND STEPPED AS REQUIRED TO MAINTAIN THE REQUIRED DEPTH BELOW THE FINAL GRADE. 1/2"x6" HILTI KWIK � 2. SOIL BEARING BASED ON 1500 PSF. "HUZ—EZ"(KH—EZ) lu TYPE ANCHOR 4'-1" 4'-0" 4'-0" 4'-0" 4'-1" 3. MAXIMUM SLOPE OF CUTS AND FILLS TO BE TWO (2) HORIZONTAL TO (MIN. EMBED. OF 3" ONE (1) VERTICAL. INTO CONCRETE) FOUNDATION NOTE: (16 TOTAL) FOUNDATION DESIGN IS BY 4. ANY FILL UNDER GRADE SUPPORTED SLABS TO BE A MIN. OF 4" IN. OTHERS BASE FRAME PLAN BUILDIINGTFORCES SUPPORT z GRANNULAR MATERIAL COMPACTED TO 95%. _ SCALE: 1/4" = 1'-0" _j m 5. CONCRETE: - MIX AND 28 DAY COMPRESSIVE STRENGTH OF CONCRETE. 11J n 2"X3"X0.072" STEEL TUBE Q FOOTINGS 3,000 PSI COLUMN SLABS ON GRADE: 3,000 PSI Y2" HILTI "HUS—EZ" DRILL —I f—2 3/4" d 6. REINFORCING STEEL TO BE A-615 GRADE 60. #4 BARS @ 12" O.C. IN ANCHOR 13/4"X"23/4"Xo.072" Z 1— ' (MINIMUM EMBED OF 3" - STEEL TUBE INSERT Z ci p 7. STEEL SPECIFICATIONS: 6" CONCRETE INTO CONCRETE) �� (n m SLAB(MIN.) ,.- r: 2"X3"XO.072" STEEL g z FRAMES AND POSTS: Fy = 50KSI Q 'pFW 'I = - TUBE BASE PLATE n PLATES AND ANGLES: Fy = 36K Y2" HILTI "HUS—EZ" DRILL , f — IN ANCHOR 6 CONCRETE SLAB(MIN.) A A FOOTING DETAIL (MINIMUM EMBED OF 3" SUPPLIER: � sl SCALE: 1/2" = 1'-0" INTO CONCRETE) GPH PREMIER STEEL STRUCTURES -`'I c ' iB BOTTOM RAIL DETAILS ONAL MCF P.O. BOX 492 SI SCALE: 1/2" = 1'-0" "� os-2o-,s 2o1s-44 SCIO, OR 97374 ace a ML 4, Zd 503-559-8191 Na FEV. WWW.PREMIERSTEELSTRUCTURES.COM 51 0 CU Z 26GA. METAL SHEETING, HORIZONTAL ROOF AND BOTH SIDES, FULLY ENCLOSED Z 4'-1" 4'-0" 4'-0" 4'-0" 4'-1" W (z) Z 00� � O Ile le V.- k . ' O O� 5" O.H.(TYP.) ���Mj LQ(z) ctLj� 5" O.H. (TYP.) Ul Z � O Q � 2"X3"X0.072" STEELTUBE Z (TYP 6)36) BOTH SIDES OF BUILDING ARE ENCLOSED 11�I V lu Z 6"(TYP.) � c ' . •'' ° • .. a n CONCRETE FOUNDATION c SLAB DESIGN " OTHERS 2"X3"X0.072" STEEL \\,--1/2"x6" (r Z (6T HILTI KWIK "HUS—EZ" HK. MIN.) TUBE BASE PLATE (KH—EZ) 3" EMBED. DEPTH. M1 1~D SPECIAL INSPECTION NOT REQUIRED. �0 P Ho g WAS R�iF d RIGHT AN SUPPLIER: D LEFT SIDE ELEVATION � �,�� �: CPH PREMIER STEEL STRUCTURES SCALE: 1/2"=1'-0" k `° MCF O ECI�iEKt% 05-20-19 P.O. BOX 492 S orvAL� NO. 2019-44 SCIO, OR 97374 T N0. 503-559-8191 nPW a,2�F C? NM FMV. WWW.PREMIERSTEELSTRUCTURES.COM C� Z Z Lo � N h� Z0)0)% O 14'-0" r�W W��� O�o�i'� i � Wo�►�o -KN ,o SEE SHEET "S6" FOR RAFTER EXTENSION U Q m h SCREW PATTERN 12 �3 R10}¢" � 2"x3"x15GA. A36 TUBE STEEL } lu � W OPEN STEEL SIDE STEEL SIDE POST Wa rl POST 26GA METAL � �/ SHEETING, HORIZONTAL � l 6 (TYP.) ILlu n Z CONCRETE FOUNDATION Ak (n jLJ In SLAB DESIGN BY OTHERS Z (6"THK. MIN.) Q►�'dvPsH�9 D- g ��woF ,qZ�,co�9 FRONT AND REAR ELEVATION Z SUPPLIER: SCALE: 1/2'=1'-0• GPH PREMIER STEEL STRUCTURES MCF P.O. BOX 492 �S'�'—I��`��� 05-20-19 SCIO, OR 97374 Na TONAL Na 20�s-a� 503-559-8191 EXPiREs APRIL 4 Na REV. WWW.PREMIERSTEELSTRUCTURES.COMrj3 CU O N h� SCREW SPACING: ROOF-12" O.C.(MIN.); SIDES-12" O.C.(MIN.) OVERLAP AT RIDGE 14'_0» WC--3 L4-j ''3 26GA(PBR) PANEL = �m�'�h AT ROOF AND SIDES '� Q ,4 12 W ���x 20" S� — 13 4 OF #12 X 1" TEK SCREWS ONE SIDE ONLY (TYP.) PEAK 2"X3"X15GA. TUBE '• Z 2"X3"X15GA. TUBE N ��0 2"X3"X14GA. TUBE RAFTER �z } 2"X2"X15GA. KNEE BRACE CHANNEL (TYP. BOTH SIDES) (2) #12x1" TEK SCREWSco z PER END INTO TUBE(TYP.) OPEN 26GA METAL O SHEETING, HORIZONTAL 2"X3"X0.072" STEEL IL TUBE SIDE POST(A36) (TYP. BOTH SIDES) 26GA METAL SHEETING, Z HORIZONTAL 6"(TYP•) 111 c�i ul a , .. . ,. • , . , ; L T 1/2"x6" HILTI KWIK "HUS-EZ" CONCRETE FOUNDATION Z z p (KH-EZ) 3" EMBED. DEPTH. SLAB DESIGN BY OTHERS In ILI 6"THK. MIN. OF SPECIAL INSPECTION NOT ( ) sN �� _ REQUIRED. SHELTER SECTI ON- �ti��0 ��C� 1. Q SCALE: 1/2"=1'-0" lu SUPPLIER: — H PREMIER STEEL STRUCTURES MCF P.O. BOX 492 �SSjONAI 05-20-19 SCIO, OR 97374 mm 2019- 44 503-559-8191 EXPIRE' APRIL 4,26Z� WWW.PREMIERSTEELSTRUCTURES.COM 5-4 O 38.791" Z 36" CN C3 N. R 4 " 3Y4" 4 12" 12" O N l0 " W Nokj (4) #12x1" 000 TEK SCREWS 26 GA. SHEET—METAL 2" �NZ (MIGHT]—RIB PBR) Wlri(3,*O 2"X3"X0.072" STEEL W O W O ,TUBE COLUMN ROOF METAL SHEETING GABLE 'W' 1 kj COLD ROLL BEND SCALE: 1"=1'-0" = Aj �QI�•lOh DETAILS J W HORIZONTAL APPLICATION A FLASH I N G DETAILS p�I ac " 0 5tj SCALE: 3" W �z 7- af 2"X3"X0.072" STEEL TUBE 13/4"X"23/4"X0.072" STEEL TUBE INSERT 00 Q V. Z z Ya» io 00 (4) #12x1" (4) #12x1" co TEK SCREWS 5'-11" TEK SCREWS lu x Z N 2"X3"X0.072" STEEL PEAK DETAIL o TUBE COLUMN SCALE: 1"=1'-0" 2"XYX0.072" STEEL V (SIDEPOST) TUBE BASE PLATE BOTTOM RAIL DETAILS z V_ -1 1" SCALE: 1/2"=1'-0" u j n 43 (4) #12X1" TEK-SCREWS �2" CRIMPED END (TO Q 33 FIT INSIDE BEAM) (TYP. ALL SECTION Z c CONNECTIONS) Z 2"XYX0.072" STEEL TUBE P H g >> >> wnsK 09y� SECTION B DETAIL 32 1/2" SCALE: 1"=1'-0" CRIMPED END (TO - z SUPPLIER. FIT INSIDE COLUMN) ; GPH PREMIER STEEL STRUCTURES A�° .t` o�z 97CF P.O. BOX RAFTER EXTENSION DETAIL S ONAL na SCIO, OR 97374 2019-44 503-559-8191 SCALE: 1"=1'-0" EXPIRES APRIL 4, jNm WWW.PREMIERSTEELSTRUCTURES.COM Br7 50 /JPF r _ ' All, BEACH, VERNON PARCEL #: 31051200100400 BEACH, VERNON PARCEL #: 31051200100500 ; 'ilk STING EASEMENT WOE K'QREA: 389.72 S.F. 1 0.261 dc� ' MPORARY EXTRA WORK AREA: 'y 1'5 S.F. 0.321 ac NORTHWEST PIPELINE CORP PARCEL #: 31051200100700 EXISTING EASEMENT WORK AREA: gZNp 2,551.279 S.F. 0.058 ac. NORTHWEST PIPELINE CORP I PARCEL #. 31051200100800 EXISTING EASEMENT WORK AREA: I CASCADE NATU GAS CORP 1 1,495.19 S.F. 0.034 ac. , PARCEL #: 31051200100600 ARLINGTON• S INGTON I METER STATION 6, 1 G� Z �' ,r• cP G LEGEND Pipeline Centerli4t .� ;' '� � ;l,r• Y J.�, N Permanent Right-of-Way o Q .. * .` Access RoadCO ,,• o 0. Property Line"� c _ + •► v Temporary Extra Work Area NOTE: ?� ppSE•3-5— New Permanent Work Area BECAUSE THIS EXHIBIT IS NOT BASED ON A Y Existing Easement Work Area PROPERTY SURVEY, THE ACTUAL RIGHT—OF—WA �Cg; AND WORKSPACE AREAS MAY VARY SLIGHTLY FROM WHAT IS SHOWN. • 1 NORTHWEST PIPELINE, ILLC APPROVED • LOCATION M.P. 1422.56 SNOHOMISH COUNTY, • 1'• 1 1 OF- SCALE�� ALIGNMENT SHEET Permit#: 2668 Permit Date: 07/16/19 Permit Type: ACCESSORY STRUCTURE Project Name: Northwest Pipeline Equipment Shelter Applicant Name: Northwest Pipeline Applicant Address: 22909 NE Redmond Fall City Rd Applicant, City, State, Zip: Redmond,WA 98053 Contact: Clay Gustaves Phone: 425-301-1068 Email: clay.gustaves@williams.com Scope of Work: Replace existing 20'x14' detached equipment shelter/canopy with a new one Valuation: 2000.00 Square Feet: 280 Number of Stories: 1 Construction Type: Occupancy Group: ID Code: Permit Issued: 07/16/2020 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 31051200100500 9111 TVEIT RD BEACH VERNON 111 Single Family Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# JTI Commercial CONSTRUCTION Services,LLC 360-815-0693 1006 Central Rd. CONTRACTOR L&I JTICOTI955DG Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status R20.ACCESSORY 08/13/2020 STRUCTURE 08/13/2020 08/13/2020 Approved FINAL Plan Reviews Date Review Type Description Assigned To Review Status 07/16/2019 ASSESSORY STRUCTURE BUILDING 07/16/2019 ASSESSORY STRUCTURE Josh Grandlienard Fees Fee Description Notes Amount Building Permit Table 4-1 $100.70 Building Plan Review Table 4-2 $65.46 Processing/Technology $25.00 State Surcharge- 1st DU Residential- 1st Unit $6.50 Credit Card Service $5.93 Total $203.59 Attached Letters Date Letter Description 07/31/2019 Building Permit 07/30/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 07/31/2019 Clay Gustaves 76363217 $197.66 07/31/2019 76363217 CC Surcharge Raelynn Jones $5.93 Outstanding Balance $0.00 Notes Date Note Created By: 07/30/2019 Emailed for business license for Northwest Pipeline Raelynn Jones 07/16/2019 Emailed for site plan Raelynn Jones 07/16/2019 Emailed for business license for contractor Raelynn Jones Uploaded Files Date File Name 10/11/2021 9867423-2668 IC 8.13.2020.pdf 09/24/2021 9758499-2668 IC 8.31.2020.pdf 07/16/2020 6992075-2668 Issued Permit.pdf 07/16/2019 5329059-ARLINGTON METER STATION-SITE MAP.pdf 07/16/2019 5329060-NW Pipeline Shelter Calculations 05-23-19.pdf 07/16/2019 5329061-NW Pipeline Shelter Plans 05-23-19.pdf 07/16/2019 5328136-2668 Structure Details.pdf 07/16/2019 5328001-2668 Application.pdf Willamette Engineering, Inc. PO Box 9032, Salem, Or 97305 Ph (503) 304-0905 Fax (503) 304-9512 STRUCTURAL CALCULATIONS FOR STEEL SHELTER AND ANCHORAGE WILLIAMS NW PIPELINE EQUIPMENT SHELTER LOCATED AT 21403 92ND AVE NE ARLINGTON, WA 98223 THESE SHEETS ARE VOID IF SEAL IS NOT RED P. 101 w .x 30�`95 �O�EGISTti��GC ONAL ExPipEs APRIL 4, v & SIGNATURE IS NOT ORIGINAL 14 PAGES NOT COUNTING COVER SHEET ****LIMITATIONS**** NO RESPONSIBILITY AND/OR LIABILITY IS ASSUMED BY, OR IS TO BE ASSIGNED TO THE ENGINEER FOR ITEMS BEYOND THAT SHOWN ON THESE SHEETS. JOB NO. 2019-44 MAY 21,2019 PREPARED BY GERALD P. HORNER,PE WILLIAMS NW PIPELINE SHELTER 21403 92ND AVE NE pa , I Of � 7 ARLINGTON,WA 98223 ASCE 7-10 WIND DESIGN FOR MAIN FORCE RESISTING SYSTEM 120 MPH ULTIMATE WIND SPEED PER OSSC FIGURE 1609A CONVERTED TO ASD DESIGN PER OSSC TABLE 1609.3.1 ROOF- 15 DEGREES -BASIC WIND SPEED- 120 MPH EXPOSURE- "C" BUILDING FEATURES • HEIGHT 10, LENGTH 20' WIDTH 14' ZONE LOAD CASE PS 30 PSF ASD-PSF I "C" PNET-PSF A 2 28.7 22.2425 1.00 1.41 31.36 B 2 -9.5 -7.3625 1.00 1.41 -10.38 C 2 19.1 14.8025 1.00 1.41 20.87 D 2 -5.4 -4.185 1.00 1.41 -5.90 E 2 -27.4 -21.235 1.00 1.41 -29.94 F 2 -17.9 -13.8725 1.00 1.41 -19.56 G 2 -19.1 -14.8025 1.00 1.41 -20.87 H 2 -13.7 -10.6175 1.00 1.41 -14.97 OVERHANG E 2 38.4 29.76 1.00 1.41 41.96 OVERHANG G 2 -30.1 -23.3275 1.00 1.41 -32.89 ZONE 5; "a" DIMENSIONS LONG DIMENSION HORIZONTAL 0.10(20')= V HEIGHT 0.4(10')= USE 3' SHORT DIMENSION HORIZONTAL 0.10(14')= 1.4' HEIGHT 0.4(10')= 4' USE 3' DESIGN CRITERIA SEISMIC-SDS=0.778 = , SOIL- 1,500 PSF, Ca=0.36 SNOW-25 PSF GROUND, ROOF DEAD LOAD-6 PSF 6 WALL DEAD INTERIOR-6 PSF WALL DEAD EXTERIOR-6 PSF STRUCTURAL FORMULAS D+ F IBC 16-8 D+H+F+L +T IBC16-9 D+H+ F+(L or S or R) IBC16-10 D+H+F+0.75*(L+T)+0.75*(L or S or R) IBC16-11 _ D+H+F+0.75*(Wor0.7E) IBC16-12 D+H+F+0.75(Wor0.7E)+0.75L+0.75(LorSorR) IBC16-13 0.6D+W+H IBC16-14 0.6D+0.7E+ H IBC 16-14 WILLAMETTE ENGINEERING, INC, PROJECT WILLIAMS NW PIPELINEJ❑B NO 2019-44 SALEM, OREGON SHELTER STRUCTURAL CALCS DATE 05-07-19 PH, 503-304-0905, FAXe 503-304-9512 BY JERRY H❑RNER PAGE _ OF Williams NW Pipeline 21403 92nd Ave NE, Arlington VVA Date and Time: 4/28/2019 8:31:12 PM MCE Parameters - Conterminous 48 States Zip Code - 98223 Central Latitude = 48.207031 Central Longitude = -121.953365 MCE MAP VALUES Short Period Map Value - Ss = 110.1% g 1.0 sec Period Map Value - S1 = 30.9% g RESIDENTIAL DESIGN INFORMATION Short Period Map Value - Ss = 110.1% g Soil Factor for Site Class D - Fa = 1.06 �.8% Residential Site Value = 2/3 x Fa x Ss Residential Seismic Design Category = ) 6ft�L tJCIGNI 51 OES - Z 5fVE3LZo, 7,S')(?9(8P307 Z-517- i- 7 g B ) L.YB(, o L.a) C%.267 F(.) K- 5-r�EL 690/rJ�42Y ?AA C I-a F2A M E E /Z- 2 - rP - saq � 8 �ERs� nc Z SIDES *------...__.------'p'-r(SIM IUK we u.a -----+ .0,072' BASE PLATE M. A f - S ERR M ES M Wes jq ZS C6.-?2 FOLOK EDGE \ 2'xz', TIUK 'MIL' K�Mf -& / fN -EZ'(KN_EZ; - f- - _-+ ;16 TOTAL) FOUNOADON NOTE. BASE FRAME PLANOTK*S" S a. WILLAMETTE ENGINEERING, INC. PROJECT WILLIAMS NW PIPELINEJOB NO 2019-44 SALEM, OREGON SHELTER STRUCTURAL CALCS DATE 05-07-19 PH, 503-304-0905, FAXi 503-304-95]12 BY JERRY HORNER PAGE OF T �A;CTH VES, ,L,y ENCLOSED t 4'-0' {-0 4'-0' 4'-0" 4'-0' 5- O.H.(TYP.) O.H. (TYP.)0­ BACK SIDE _4 BUILDING 1 2 C,072" STEE-: It le TUBE'('AW BOTH SIDES OF 9L TYP 6) BUILDING ARE ENCLOSED Oy,! if0 L'P , !, tETE FOUNDATION -SIGN BY OTHERS 2-)(3"XO 072" STEEL i6_THK MIN) -----"BE BASE PLATE 1/2 HILT; KY,"K "HUS-EZ' (KH_EZ) 3' EMBED. DEPTH SPECIAL INSPECTION NOT REQUIRED RIGHT AND LEFT SIDE ELEVATION 3(01E MULL la 4 7S/ 4LI- T'S6_ FOR 26GA(PBR)PANEL W PATTERN -c P/-V: PA AT ROOF AND SIDES W A 12 1 13 4 OF III X I' TEK SCREWS I ONE SIDE ONLY (TYP.) 2*X3-Xl5GA. TUBE 0, bf " x3XI5GA R.A rFUTBEER 2*X3'X15GA, TUBE ✓ 0,S cr 8 11'1.3 Lo 7,81 P%r PEN \-26GA METAL 1 ` SHEETING, La +/ S I HORIZONTAL 2'X3*XO.072' STEEL 960 p m ie ti 16c_Jz TUBE SIDE POST(A36) 0,5 (TYP. BOTH SIDES) ktjlx 26GA METAL SHEETING. C>6 A 0 a L'� z3 HORIZONTAL :5 .4rff f5r 7, F=!: RAM F_ CONCRETE FOUNDATION 2 P1 F SLAB DESIGN BY OTHERS (6-THK, Mlk)­ / 14.6 0 FRONT ELEVATION g1-1,:3,/ Fr-L 6 63 ,:, 66 K 5T 6 ,96q"1?;T,4 3� tied Psi' —,ok WILLAMETTE ENGINEERING, INC. PROJECT WILLIAMS NW PIPELINE)❑B NO 2019-44 SALEM, OREGON SHELTER STRUCTURAL CALCS DATE 05-07-19 PH, 503-304-0905, FAX, 503-304-9512 BY JERRY HORNER PAGE 5y OF fy -r- �Zs 3Z9 )PsF) 3.�`�Ys')C�.g�PSF� -�sZ LB 50? L 8 415 E t Jl NO Za! o F Z!p Grq Sf RT'H! cal G '7 ,52 Le/Za `= 3 8 Rz F 5;4r � cAPf GI-rY= Zq!o PL > 3 �5 PLF /nK LAP L► F 1" 4T 2 a u i' L4 5 E � ' FO 2 a vE KAA Al(n FACI4 SI E (1Z . a9 P5F)C���C� � = 13 dl LS UPC, FT 5 6 Ld L M)5- S - 1602 O�sgg �rIV3 ' ��- �K 3�, k 52 �ouv e S d F I www.hilti.us Profis Anchor 2.6.3 Company: Willamette Engineering, Inc. Page: 1 Specifier: Gerald Horner Project: Williams NW Pipeline Address: PO Box 9032 Sub-Project I Pos. No.: One 1/2"Anchor Phone I Fax: 503-304-0905 1 503-304-9512 Date: 5/8/2019 E-Mail: jer.willengr@juno.com Specifier's comments:Piping Shelter Concrete Connection,21403 92nd Ave NE,Arlingon,WA 1 Input data Anchor type and diameter: KWIK HUS-EZ(KH-EZ)1/2(3) Effective embedment depth: hef=2.160 in., hnam=3.000 in. Material: Carbon Steel Evaluation Service Report: ESR-3027 Issued I Valid: 1 2/11201 5 1 1 2/1/201 7 Proof: Design method ACI 318/AC193 Stand-off installation: eb=0.000 in.(no stand-off);t=0.250 in. Anchor plate: Ix x ly x t=4.000 in.x 8.000 in.x 0.250 in.;(Recommended plate thickness:not calculated Profile: Rectangular plates and bars(AISC);(L x W x T)=0.250 in.x 0.188 in.x 0.000 in. Base material: cracked concrete,3000,f�=3000 psi;h=6.000 in. Reinforcement: tension:condition B,shear:condition B; no supplemental splitting reinforcement present edge reinforcement: none or<No.4 bar Seismic loads(cat.C,D, E,or F) no Geometry[in.]&Loading[Ib,in.Ib] Z �1 CF1 o IV -�;- - -- - - 0 �--. >t .. .. X Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan P e- 6 Af 11 I I ML-0 Z1 www.hilti.us Profis Anchor 2.6.3 Company: Willamette Engineering, Inc. Page: 2 Specifier: Gerald Horner Project: Williams NW Pipeline Address: PO Box 9032 Sub-Project I Pos.No.: One 1/2"Anchor Phone I Fax: 503-304-0905 1 503-304-9512 Date: 5/8/2019 E-Mail: jer.willengr@juno.com 2 Load case/Resulting anchor forces y Load case:Design loads Anchor reactions[Ib] Tension force:(+Tension,-Compression) Anchor Tension force Shear force Shear force x Shear force y 1 1549 320 313 68 max.concrete compressive strain: -I&I x max.concrete compressive stress: -[psi] Te Ion resulting tension force in(x/y)=(0.000/0.000): 1549[lb] resulting compression force in(x/y)=(0.000/0.000):0[lb] 3 Tension load Load Nua[lb] Capacity#N„[lb] Utilization p=Nua/+N Status Steel Strength* 1549 11778 14 OK Pullout Strength* N/A N/A N/A N/A Concrete Breakout Strength** 1549 1921 81 OK *anchor having the highest loading **anchor group(anchors in tension) 3.1 Steel Strength Nsa =ESR value refer to ICC-ES ESR-3027 �Nsa Nua ACI 318-08 Eq.(D-1) Variables Ase,N[in.2] fut.[psi] 0.16 112540 Calculations Nsa[lb] 18120 Results Nsa[lb] y steel Nsa[lb] Nua[lb] 18120 0.650 11778 1549 Input data and results must be checked for agreement with the existing conditions and for plausibility' PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan pole e o F �Y www.hilti.us Profis Anchor 2.6.3 Company: Willamette Engineering, Inc. Page: 3 Specifier: Gerald Horner Project: Williams NW Pipeline Address: PO Box 9032 Sub-Project I Pos. No.: One 1/2"Anchor Phone I Fax: 503-304-0905 1 503-304-9512 Date: 5/8/2019 E-Mail: jer.willengr@juno.com 3.2 Concr1/rete Breakout Strength ANC Ncb _ `ANco)lVed,N lVc,N ll/cp,N Nb ACI 318-08 Eq.(D-4) Ncb>Nua ACI 318-08 Eq.(D-1) ANc see ACI 318-08, Part D.5.2.1, Fig. RD.5.2.1(b) ANco =9 hef ACI 318-08 Eq.(D-6) 1 Yec,N = 1 +2 eN <_1.0 ACI 318-08 Eq.(D-9) 3 het Yed,N =0.7+0.3 (Gamin)�1.0 ACI 318-08 Eq.(D-11) `1.5hef lVcp N =MAX SL n 1.5hef\ c 1.0 ACI 318-08 Eq.(D-13) `\ Cac Cac l Nb =kc x 4c hefs ACI 318-08 Eq.(D-7) Variables hef[In.] ec,,N[in.] ec2,N[In.] ca,min[in.] we N 2.160 0.000 0.000 7.000 1.000 cap[in.] kc k fc[psi] 3.750 17 1 3000 Calculations AN,(in.2] ANco[in.2] llfecl,N Yec2,N ilfed,N llfcp,N Nb[lb] 41.99 41.99 1.000 1.000 1.000 1.000 2956 Results Ncb[ib] concrete NO[lb] Nua[lb] 2956 0.650 1921 1549 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 13 v� www.hilti.us Profis Anchor 2.6.3 Company: Willamette Engineering, Inc. Page: 4 Specifier: Gerald Horner Project: Williams NW Pipeline Address: PO Box 9032 Sub-Project I Pos. No.: One 1/2"Anchor Phone I Fax: 503-304-0905 1 503-304-9512 Date: 5/8/2019 E-Mail: jer.willengr@juno.com 4 Shear load Load Vua[lb] Capacity ilVn[lb] Utilization pv=Vua/�Vn Status Steel Strength" 320 5547 6 OK Steel failure(with lever arm)' N/A N/A N/A N/A Pryout Strength'* 320 2069 16 OK Concrete edge failure in direction x+'• 320 2670 12 OK "anchor having the highest loading "anchor group(relevant anchors) 4.1 Steel Strength Vsa =ESR value refer to[CC-ES ESR-3027 Vsteel>Vua ACI 318-08 Eq.(D-2) Variables Ase,y[in,2] futa[psi] 0.16 112540 Calculations Vsa[lb] 9245 Results Vsa[lb] steel 41 Vsa[lb] Vua[lb] 9245 0.600 5547 320 4.2 Pryout Strength Vcp =kcp[(AN o)yfed,N Wc,N Ycp,N NbJ ACI 318-08 Eq. (D-30) Vcp>_Vua ACI 318-08 Eq. (D-2) AN, see ACI 318-08,Part D.5.2.1, Fig. RD.5.2.1(b) AN, =9 hef ACI 318-08 Eq. (D-6) 1 yfec,N — 1 +2 eN)_<1.0 ACI 318-08 Eq. (D-9) 3 hef/ Wed,N=0.7+0.3 (ca,min)5 1.0 ACI 318-08 Eq. (D-11) 1.5hef Wcp N =MAX S 1.5hef)c 1.0 ACI 318-08 Eq.(D-13) cac Cac Nb =kc a,�fc hef5 ACI 318-08 Eq.(D-7) Variables kcp hef[in.] ec1,N[in.] ec2,N[in.] ca,min[in.] 1 2.160 0.000 0.000 7.000 tVc,N cac[in] kc 21 f,[psi] 1.000 3.750 17 1 3000 Calculations ANc(in.2] ANco[in.2] lVec1,N lVec2,N lVed,N 1Vcp,N Nb[lb] 41.99 41.99 1.000 1.000 1.000 1.000 2956 Results Vcp[lb] concrete Vcp[lb] Vua[lb] 2956 0.700 2069 320 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan pact C) �+ I www.hilti.us Profis Anchor 2.6.3 Company: Willamette Engineering, Inc. Page: 5 Specifier: Gerald Horner Project: Williams NW Pipeline Address: PO Box 9032 Sub-Project I Pos.No.: One 1/2"Anchor Phone I Fax: 503-304-0905 1 503-304-9512 Date: 5/8/2019 E-Mail: jer.willengr@juno.com 4.3 Concrete edge failure in direction x+ Ave Vcb = (Av o)tVed,V tVc,V tVh,V tVparallel,V Vb ACI 318-08 Eq.(D-21) Vcb>Via ACI 318-08 Eq.(D-2) Avc see ACI 318-08, Part D.6.2.1, Fig. RD.6.2.1(b) Avco =4.5 Cat ACI 318-08 Eq. (D-23) 1 tVec,v = 1 + 2e„ <_1.0 ACI 318-08 Eq. (D-26) 3Cat Y/d,V =0.7+0.3(1 Scat)<_ 1.0 ACI 318-08 Eq. (D-28) Wh,v = 1.5Cat >_1.0 ACI 318-08 Eq.(D-29) ha 0.2 Vb = (7 (a) a �cats ACI 318-08 Eq.(D-24) a Variables cat [in.] Cat[in] ecv[in.] tVc.v ha[in.] 7.000 7.000 0.000 1.000 6.000 le[In.] a da[In.] fc[psi] lVparallel,V 2.160 1.000 0.500 3000 1.000 Calculations Avc[in.2] Avoo[in.2] kVec,V tVed,V Wh,V Vb[lb] 105.00 220.50 1.000 0.900 1.323 6728 Results Vcb[lb] concrete Vcb[lb] V a[lb] 3814 0.700 2670 320 5 Combined tension and shear loads ON (iV Utilization(3N,V[%] Status 0.806 0.155 5/3 75 OK RNV=P�+RV<= 1 6 Warnings • Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered.The anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the loading! Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies when supplementary reinforcement is used.The q)factor is increased for non-steel Design Strengths except Pullout Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength. Refer to your local standard. • Refer to the manufacturer's product literature for cleaning and installation instructions. • Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard! Fastening meets the design criteria! Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan a e i0 www.hilti.us Profis Anchor 2.6.3 Company: Willamette Engineering, Inc. Page: 6 Specifier: Gerald Horner Project: Williams NW Pipeline Address: PO Box 9032 Sub-Project I Pos. No.: One 1/2"Anchor Phone I Fax: 503-304-0905 1 503-304-9512 Date: 5/8/2019 E-Mail: jer.willengr@juno.com 7 Installation data Anchor plate,steel:- Anchor type and diameter: KWIK HUS-EZ(KH-EZ) 1/2(3) Profile: Rectangular plates and bars(AISC);0.250 x 0.188 x 0.000 in. Installation torque:540.001 in.lb Hole diameter in the fixture:df=0.625 in. Hole diameter in the base material:0.500 in. Plate thickness(input):0.250 in. Hole depth in the base material:3.375 in. Recommended plate thickness: not calculated Minimum thickness of the base material:4.750 in. Drilling method: Hammer drilled Cleaning:Manual cleaning of the drilled hole according to instructions for use is required. 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer Manual blow-out pump Torque wrench • Properly sized drill bit Y 2.000 2.000 0 0 0 0 v v X 0 0 0 0 v v 2.000 2.000 Coordinates Anchor in. Anchor X y c_x c.x c_y c.y 1 0.000 0.000 12.000 7.000 7.000 12.000 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan Q 2 I .6 N.S- SERVICE Most Widely Accepted ancil Trusted ICC-ES Evaluation Report ESR-3294 Reissued February 1, 2014 This report is subject to renewal April 1, 2016. www.icc-es.org ( (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 05 00 00—METALS 3.2 Standard Drill Screws: Section: 05 05 23—Metal Fastenings 3.2.1 EDC450 (Type 1): The EDC450 screw has coarse threads and an indented high hex washer head with an DIVISION: 06 00 00—WOOD, PLASTICS AND undercut. This screw complies with the thread design, COMPOSITES material specifications and performance requirements of Section: 06 05 23—Wood, Plastics and Composite ASTM C1513. Fastenings 3.2.2 EDB446, EDB486, EDB541, EDB571 (Type 2): REPORT HOLDER: These screws have coarse threads and an indented high hex washer head. These screws comply with ASTM ELCO CONSTRUCTION PRODUCTS/ C1513. an INFASTECH COMPANY 3.2.3 EDC745 (Type 3): The EDC745 screw has coarse 1302 KERR DRIVE threads and an indented hex washer head. This screw DECORAH,IOWA 52101 complies with ASTM C1513. (800)435-7213 3.2.4 EDB741, EDB761, EDB782, EDB801, EDB821, www.elcoconstruction.com EDB830, EDB840, EDB845 (Type 4) and EDA790 (Type infoElcona infastech.com 4A): These screws have coarse threads and an indented hex washer hea'.The screws comply with ASTM C1513. EVALUATION SUBJECT: 3.2.5 EDC930 (Type 5): The EDC930 screw has coarse threads and an indented hex washer head which is smaller ELCO CASE-HARDENED SELF-DRILLING TAPPING than that required by ASME B18.6.4. The screw complies SCREWS with the thread design, material specifications and performance requirements of ASTM C1513. 1.0 EVALUATION SCOPE 3.2.6 EDB936, EDB946, EDB956, EDB961, EDB971, Compliance with the following codes: EDB976, EDB981, EDB983 (Type 6): These screws have 11 2012,2009 and 2006 International Building Code(IBC) coarse threads and an indented hex washer head. These screws comply with ASTM C1513. 2012 and 2009 International Residential Code (IRC) 3.3 Drill Screws with Extended Drilling Capacity: Property evaluated: 3.3.1 EDC801, EDC816 (Type 7): These screws have Structural fine threads and an indented hex washer head. The 2.0 USES spacing of the lead threads is greater than the spacing of the remainder of the threads. These screws comply with Elco case-hardened self-drilling tapping screws are used to ASTM C1513. connect cold-formed steel members together, to connect 3.3.2 ECC720, ECC740, ECC750 (Type 8): These cold-formed steel to hot-rolled steel plates and to connect screws have fine threads and an indented hex washer wood structural panel sheathing to cold-formed steel. The head. The threads nearest the drilling point are slightly screws are used to resist shear and tension loads in deformed and the manufacturer describes the thread engineered connections and are used in connections design as Round Body Taptitel'.These screws comply with prescribed by the code for steel-to-steel and wood-to-steel the material specifications and performance requirements connections. of ASTM C1513. 3.0 DESCRIPTION 3.4 Architectural Roof Clip Fasteners [ED0450, 3.1 General: ED0460, ED0470(Type 9)1: The Elco screws are self-drilling tapping screws formed The fasteners are coarse thread screws with pancake-style from carbon steel wire conforming to ASTM F2282, Grade heads.These screws comply with ASTM C1513. 1018 - 1022, and case-hardened to 50 to 56 HRC. The 3.5 Drilit'D Drill Screws: screws are coated with a prWrietary corrosion-resistant 3.5.1 EDT602 (Type 10): The EDT602 screw has fine coating identified as Stalgard . Table 1 provides screw threads and a phillips wafer head. Between the threads descriptions including type, size, threads per inch (tpi), and the drill point,the screw has a portion of smooth shank nominal diameter, head style, head diameter, point type, with two projecting wings. The EDT602 screw complies length, drilling capacity, length of load bearing area, and with the thread design, material specifications and coating information. performance requirements of ASTM C1513. ICC-ES Evaluation Reports are not to he construed as representing aesthetics or om-other attributes no,specTical[y addressed,nor are Iher to be construed as an endorsement of the subject of the report or a recommendation Jor its use.There is no warranty by ICC Evaluation Service.LLC,express or implied,as =.,41 to any rutting or other matter in this report,at-as to any pr(duct covered bt the reprnt. - Copyright,'9)2014 Page 1 of 8 ESR-3294 I Most Widely Accepted and Trusted fLZ,,0 _-_2L_ 9�&J D?f�_ Page'12 4 I y TABLE 2-ELCO SELF-DRILLING SCREWS SHEAR AND TENSION FASTENER STRENGTH(Ibf) DESIGNATION NOMINAL STRENGTH ALLOWABLE STRENGTH(ASD) DESIGN STRENGTH (LRFD) Shear:P. Tension:Pt Shear:PJf� Tension:PVO Shear:mP� Tension:OP, STANDARD DRILL SCREWS #10-16 1679 2670 560 890 840 1335 #12-14 2032 3211 667 1070 1016 1606 '/4-14 2559 5021 853 1674 1280 2511 EXTENDED DRILLING CAPACITY SCREWS #12-24 2283 4034 1 761 1 1345 1142 2017 ARCHITECTURAL ROOF CLIP FASTENERS #10-16 1560 2326 520 775 780 1163 For SI:1 inch=25.4 mm,1 Ibf=4.4 N. TABLE 3A-ALLOWABLE(ASD)SHEAR(BEARING)CAPACITY OF SCREW CONNECTIONS"'',Ibf THICKNESS THICKNESS OF STEEL NOT IN CONTACT WITH SCREW HEAD(in.) NOMINAL OF STEEL IN DESIGNATION DIAMETER CONTACT (in.) WITH 0.030 0.036 0.048 0.060 0.075 0.090 0.125 0.188 0.250 0.375 SCREW - HEAD(in.) STANDARD DRILL SCREWS 0.030 143 193 231 231 231 231 231 - 0.036 143 188 277 277 277 277 277 - - #10-16 0.190 0.048 143 188 289 369 369 369 369 - 0.060 143 188 289 404 462 462 - - - 0.075 143 188 289 404 564 577 - 0.090 143 188 289 404 564 693 - - 0.030 150 205 255 255 255 255 255 255 - 0.036 150 197 304 306 306 306 306 - - - 0.048 150 197 408 408 408 408 C#12-14' ` 0.216 0.060 150 197 304 424 510 510 510 - - - 0.075 150 197 304 424 593 638 638 - - 0.090 150 197 304 424 593 765 765 - - - 0.125 150 197 304 424 593 765 - - - - 0.030 160 222 292 292 292 292 292 292 - - 0.036 160 211 325 350 350 350 350 - 0.048 160 211 325 454 467 467 467 - - - 1/4-14 0.250 0.060 160 211 325 454 583 583 583 - - - 0.075 160 211 325 454 634 729 729 - - - 0.090 160 211 325 454 634 833 875 - 0.125 160 1 211 1 325 454 634 833 - EXTENDED DRILLING CAPACITY SCREWS 0.036 - - - 404 370 400 #12-24 0.216 0.060 - - - 829 630 677 0.090 - - - 588 643 667 ARCHITECTURAL ROOF CLIP FASTENERS #10-16 0.190 0.030 232 286 350 335 - - 0.036 - 343 423 484 472 - - -For SI: 1 inch=25.4 mm, 1 Ibf=4.4 N, 1 ksi=6.89 MPa. "See notes following Table 36. & /3 Premier Steel Structures E3 R Roof and Wall Panel 1 Z„ Painted Side 1�.._ 4 ji I 1%" �% „ 36" Coverage DESCRIPTIONCOMMERCIAL EXPOSED 36" COVERAGE MINIMUM SLOPE OPEN FRAMING FASTENERS 1/2 :12 PANEL Applications: Industrial, Commercial, and Agricultural — Limited 40-year warranty paint — Finishes 26 ga: 10 standard SMP colors and Galvalume® Finishes 24 ga: 10 standard PVDF colors — Corrosion Protection on Substrate: —AZ-50 (ASTM A792) for painted Galvalume® —AZ-55 (ASTM A792) for unpainted, acrylic coated, Galvalume® — G-60 (ASTM A653) for painted Galvanized — G-90 (ASTM A653) for PVDF painted 24 gauge Sheet lengths: 1' to 50'-0" in one inch increments — Polycarbonate and fiberglass light panels available in PBR profile — For color availability, cool roof specs, and other panel info, please see our website: www.metalIionindustries.com TESTING DATA — UL 2218 Impact Resistance U0 L — UL 790, 263 Fire Resistance r — UL 580 Uplift Resistance PBR Allowable Loads Ilbs/ftzl per span Wind Load - • Ga Span Load Type 2' 2.5' 3' 3.5' 4' 4.5' 5' 5.5' 6' 6.5' 7' Wind Load(Uplift) 257 164 114 83 64 50 40 33 28 24 20 Single Live Load Deflection 295 166 107 78 P 42 33 26 21 18 15 Wind Load(Uplift) 199 132 94 6942 34 29 24 20 17 Double Live Load Deflection 575 363 134 99 76 60 48 37 30 24 20 Wind Load(Uplift) 239 160 115 86 66 53 43 36 30 25 22 Triple Live Load Deflection 448 285 146 108 84 67 53 42 34 28 23 26 gauge has.0184"min Substrate Thickness,80 KSI Tensile,and Weighs about.9 Ibs per Sq.Ft. Ga Span Load Type 2' 2.5' 3' 3.5' 4' 4.5' 5' 5.5' 6' 6.5' 7' Wind Load(Uplift) 294 196 135 98 75 60 48 39 34 27 24 Single Live Load Deflection 285 183 125 91 70 56 45 37 31 26 22 24 Wind Load(Uplift) 268 178 130 96 74 59 48 39 33 29 24 Double Live Load Deflection 274 180 125 92 71 57 46 38 31 27 23 Wind Load(Uplift) 321 213 F14 110 85 68 54 46 38 32 28 Triple Live Load Deflection 334 222 115 89 71 1 57 47 1 40 34 29 24 gauge has.0236"min Substrate Thickness,50 KSI Tensile(UL),Panel Width:36",ASTM A653 1.Deflection loads are based on a maximum deflection ration of L/180 of span 2.Loads are averages from similar products with design loads meeting AISI specifications 20'-2" (STEEL TUBE BASE RAIL) Z GENERAL NOTES: " " TYP. 2 x3 x0.072 171 z p STEEL TUBE 1. ALL WORK IS TO COMPLY WITH THE LATEST ADOPTED VERSION OF THE BASE PLATE NP. 51 STATE OF WASHINGTON BUILDING CODE AND ANY APPLICABLE STATE, SI (TYP. SIDES) tO W �Lr)� COUNTY OR LOCAL JURISDICTION. �3-(TYP.) 3 2. THE CONTRACTOR IS RESPONSIBLE TO CHECK THE PLANS AND IS TO WpCap► ) NOTIFY THE ENGINEER OF ANY ERRORS OR OMISSIONS PRIOR TO THE W W�L I START OF CONSTRUCTION. 18 KNEE BRACE AT (4) INTERIOR ,O� FRAMES(TYP. BOTH Qm�ln 3. WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED i^- SIDES) DIMENSIONS. DO NOT SCALE THE DRAWINGS. ���'K 4. RISK FACTOR: CATEGORY 3 v 0 5. DESIGN LOADS: GROUND (LIVE LOAD) (SNOW) 25PSF, I=1.1 i WIND - 120MPH ULTIMATE SPEED, EXPOSURE "C", 1=1.0 T 6. SEISMIC: Sds = 0.778; I =1.25 FOUNDATION IL GENERAL NOTES: 3" T"P EDGE lu 1. FOOTINGS ARE TO BEAR ON UNDISTURBED LEVEL SOIL DEVOID OF ANY ORGANIC MATERIAL AND STEPPED AS REQUIRED TO MAINTAIN THE REQUIRED DEPTH BELOW THE FINAL GRADE. 1/2"x6" HILTI KWIK � 2. SOIL BEARING BASED ON 1500 PSF. "HUZ—EZ"(KH—EZ) lu TYPE ANCHOR 4'-1" 4'-0" 4'-0" 4'-0" 4'-1" 3. MAXIMUM SLOPE OF CUTS AND FILLS TO BE TWO (2) HORIZONTAL TO (MIN. EMBED. OF 3" ONE (1) VERTICAL. INTO CONCRETE) FOUNDATION NOTE: (16 TOTAL) FOUNDATION DESIGN IS BY 4. ANY FILL UNDER GRADE SUPPORTED SLABS TO BE A MIN. OF 4" IN. OTHERS BASE FRAME PLAN BUILDIINGTFORCES SUPPORT z GRANNULAR MATERIAL COMPACTED TO 95%. _ SCALE: 1/4" = 1'-0" _j m 5. CONCRETE: - MIX AND 28 DAY COMPRESSIVE STRENGTH OF CONCRETE. 11J n 2"X3"X0.072" STEEL TUBE Q FOOTINGS 3,000 PSI COLUMN SLABS ON GRADE: 3,000 PSI Y2" HILTI "HUS—EZ" DRILL —I f—2 3/4" d 6. REINFORCING STEEL TO BE A-615 GRADE 60. #4 BARS @ 12" O.C. IN ANCHOR 13/4"X"23/4"Xo.072" Z 1— ' (MINIMUM EMBED OF 3" - STEEL TUBE INSERT Z ci p 7. STEEL SPECIFICATIONS: 6" CONCRETE INTO CONCRETE) �� (n m SLAB(MIN.) ,.- r: 2"X3"XO.072" STEEL g z FRAMES AND POSTS: Fy = 50KSI Q 'pFW 'I = - TUBE BASE PLATE n PLATES AND ANGLES: Fy = 36K Y2" HILTI "HUS—EZ" DRILL , f — IN ANCHOR 6 CONCRETE SLAB(MIN.) A A FOOTING DETAIL (MINIMUM EMBED OF 3" SUPPLIER: � sl SCALE: 1/2" = 1'-0" INTO CONCRETE) GPH PREMIER STEEL STRUCTURES -`'I c ' iB BOTTOM RAIL DETAILS ONAL MCF P.O. BOX 492 SI SCALE: 1/2" = 1'-0" "� os-2o-,s 2o1s-44 SCIO, OR 97374 ace a ML 4, Zd 503-559-8191 Na FEV. WWW.PREMIERSTEELSTRUCTURES.COM 51 0 CU Z 26GA. METAL SHEETING, HORIZONTAL ROOF AND BOTH SIDES, FULLY ENCLOSED Z 4'-1" 4'-0" 4'-0" 4'-0" 4'-1" W (z) Z 00� � O Ile le V.- k . ' O O� 5" O.H.(TYP.) ���Mj LQ(z) ctLj� 5" O.H. (TYP.) Ul Z � O Q � 2"X3"X0.072" STEELTUBE Z (TYP 6)36) BOTH SIDES OF BUILDING ARE ENCLOSED 11�I V lu Z 6"(TYP.) � c ' . •'' ° • .. a n CONCRETE FOUNDATION c SLAB DESIGN " OTHERS 2"X3"X0.072" STEEL \\,--1/2"x6" (r Z (6T HILTI KWIK "HUS—EZ" HK. MIN.) TUBE BASE PLATE (KH—EZ) 3" EMBED. DEPTH. M1 1~D SPECIAL INSPECTION NOT REQUIRED. �0 P Ho g WAS R�iF d RIGHT AN SUPPLIER: D LEFT SIDE ELEVATION � �,�� �: CPH PREMIER STEEL STRUCTURES SCALE: 1/2"=1'-0" k `° MCF O ECI�iEKt% 05-20-19 P.O. BOX 492 S orvAL� NO. 2019-44 SCIO, OR 97374 T N0. 503-559-8191 nPW a,2�F C? NM FMV. WWW.PREMIERSTEELSTRUCTURES.COM C� Z Z Lo � N h� Z0)0)% O 14'-0" r�W W��� O�o�i'� i � Wo�►�o -KN ,o SEE SHEET "S6" FOR RAFTER EXTENSION U Q m h SCREW PATTERN 12 �3 R10}¢" � 2"x3"x15GA. A36 TUBE STEEL } lu � W OPEN STEEL SIDE STEEL SIDE POST Wa rl POST 26GA METAL � �/ SHEETING, HORIZONTAL � l 6 (TYP.) ILlu n Z CONCRETE FOUNDATION Ak (n jLJ In SLAB DESIGN BY OTHERS Z (6"THK. MIN.) Q►�'dvPsH�9 D- g ��woF ,qZ�,co�9 FRONT AND REAR ELEVATION Z SUPPLIER: SCALE: 1/2'=1'-0• GPH PREMIER STEEL STRUCTURES MCF P.O. BOX 492 �S'�'—I��`��� 05-20-19 SCIO, OR 97374 Na TONAL Na 20�s-a� 503-559-8191 EXPiREs APRIL 4 Na REV. WWW.PREMIERSTEELSTRUCTURES.COMrj3 CU O N h� SCREW SPACING: ROOF-12" O.C.(MIN.); SIDES-12" O.C.(MIN.) OVERLAP AT RIDGE 14'_0» WC--3 L4-j ''3 26GA(PBR) PANEL = �m�'�h AT ROOF AND SIDES '� Q ,4 12 W ���x 20" S� — 13 4 OF #12 X 1" TEK SCREWS ONE SIDE ONLY (TYP.) PEAK 2"X3"X15GA. TUBE '• Z 2"X3"X15GA. TUBE N ��0 2"X3"X14GA. TUBE RAFTER �z } 2"X2"X15GA. KNEE BRACE CHANNEL (TYP. BOTH SIDES) (2) #12x1" TEK SCREWSco z PER END INTO TUBE(TYP.) OPEN 26GA METAL O SHEETING, HORIZONTAL 2"X3"X0.072" STEEL IL TUBE SIDE POST(A36) (TYP. BOTH SIDES) 26GA METAL SHEETING, Z HORIZONTAL 6"(TYP•) 111 c�i ul a , .. . ,. • , . , ; L T 1/2"x6" HILTI KWIK "HUS-EZ" CONCRETE FOUNDATION Z z p (KH-EZ) 3" EMBED. DEPTH. SLAB DESIGN BY OTHERS In ILI 6"THK. MIN. OF SPECIAL INSPECTION NOT ( ) sN �� _ REQUIRED. SHELTER SECTI ON- �ti��0 ��C� 1. Q SCALE: 1/2"=1'-0" lu SUPPLIER: — H PREMIER STEEL STRUCTURES MCF P.O. BOX 492 �SSjONAI 05-20-19 SCIO, OR 97374 mm 2019- 44 503-559-8191 EXPIRE' APRIL 4,26Z� WWW.PREMIERSTEELSTRUCTURES.COM 5-4 O 38.791" Z 36" CN C3 N. R 4 " 3Y4" 4 12" 12" O N l0 " W Nokj (4) #12x1" 000 TEK SCREWS 26 GA. SHEET—METAL 2" �NZ (MIGHT]—RIB PBR) Wlri(3,*O 2"X3"X0.072" STEEL W O W O ,TUBE COLUMN ROOF METAL SHEETING GABLE 'W' 1 kj COLD ROLL BEND SCALE: 1"=1'-0" = Aj �QI�•lOh DETAILS J W HORIZONTAL APPLICATION A FLASH I N G DETAILS p�I ac " 0 5tj SCALE: 3" W �z 7- af 2"X3"X0.072" STEEL TUBE 13/4"X"23/4"X0.072" STEEL TUBE INSERT 00 Q V. Z z Ya» io 00 (4) #12x1" (4) #12x1" co TEK SCREWS 5'-11" TEK SCREWS lu x Z N 2"X3"X0.072" STEEL PEAK DETAIL o TUBE COLUMN SCALE: 1"=1'-0" 2"XYX0.072" STEEL V (SIDEPOST) TUBE BASE PLATE BOTTOM RAIL DETAILS z V_ -1 1" SCALE: 1/2"=1'-0" u j n 43 (4) #12X1" TEK-SCREWS �2" CRIMPED END (TO Q 33 FIT INSIDE BEAM) (TYP. ALL SECTION Z c CONNECTIONS) Z 2"XYX0.072" STEEL TUBE P H g >> >> wnsK 09y� SECTION B DETAIL 32 1/2" SCALE: 1"=1'-0" CRIMPED END (TO - z SUPPLIER. FIT INSIDE COLUMN) ; GPH PREMIER STEEL STRUCTURES A�° .t` o�z 97CF P.O. BOX RAFTER EXTENSION DETAIL S ONAL na SCIO, OR 97374 2019-44 503-559-8191 SCALE: 1"=1'-0" EXPIRES APRIL 4, jNm WWW.PREMIERSTEELSTRUCTURES.COM Br7 50