Loading...
HomeMy WebLinkAbout17714 31st Dr Ne_BLD2630_2026 NOTICE TO PERMITEE AND/OR OWNER PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY WAPPROVED PERMIT#: ` C LOT#: DATE: J C c_- ]OB ADDRESS: •_ 1.7 TYPE OF INSPECTION: i ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK:MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THEACTIONS OR CORRECTIONS INDICATED ABOVEARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 NSPECTOR DATE - UILDING DEPT. /0 PLANNING DEPT. CITY OF ARLINGTON S i i, CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address: 17714 31st Dr NE Permit#:2630 Parcel#:00621300002600 Valuation:0 00 OWNER APPLICANT CONTRACTOR Name:BLACKBURN PROPERTIES LLC Name:Washington Energy Services Name:WASHINGTON ENERGY SERVICES Address:PO BOX 789 Address:3909 196th St SW Address:3909 196th Street SW City,State Zip:BURLINGTON,WA 98233 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036 Phone: Phone:206-378-6613 Phone:800-398-4663 LIC: EXP: MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Washington Energy Services Name: Address:3909 196th St SW Address: City,State,Zip:Lynnwood,WA 98036 City,State,Zip: Phone:800-398-4663 Phone: LIC#:WASHIES85INS EXP: 09/07/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI 10/IRC1I0. ALES T.VAN roTicr:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and cue lll� +I: r on#3101. NIKKI Y 07/23/2019 rt4d 6/25/19 Sim&dre Print Name Date I eased By Date CONDITIONS Adhere to approved appliance. Call for inspections. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 6/25/2019 Furnace $25.00 6/25/2019 Mechanical Permit Base Fee $25.00 6/25/2019 Processing/Technology Fee $25.00 6/25/2019 Water Heater $25.00 Total Due: $100.00 Total Payment: $0.00 Balance Due: $100.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon �. .., I I I Permit Information Date 6/25/2019 Permit Number 2630 Project Name 17714 31st Dr NE Applicant Name Washington Energy Services Applicant Address 3909 196th St SW City,State,Zip Lynnwood,WA 98036 Contact Phone 206-378-6613 Email Nhyett-schnell@washingtonenergy.com Permit Type Residential Mechanical Site Address 17714 31st Dr NE Valuation 0.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Residential Mechanical Number of Stories 0 Proposed Use Install gas furnace and gas water heater MIC/Opportunity Zone Assigned To I Raelynn Jones Property Parcel Address Legal Owner Owner Phone Zoning 00621300002600 117714 31ST DR NE BLACKBURN PROPERTIES LLC 1111 Single Family Residence-Detached Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# NASHINGTON ENERGY SERVICES ✓aness Stephenson 400-398-4663 ;ONTRACTOR (Labor&Industries NASHIES851NS Fees Fee Description Notes Amount Furnace 322.10.00.00 $25.00 Mechanical Permit Base Fee 322.10.00.00 $25.00 Processing/Technology Fee 341.43.00.02 $25.00 Water Heater 322.10.00.00 $25.00 Total $100.00 Uploaded Files Upload File Date File Uploaded B 6/25/2019 3:06:35 PM 2630 Specs.pdf Jones,Raelynn 6/25/2019 2:47:06 PM 2630 Application.pdf Jones,Raelynn 1 I I RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:17714 31st Dr NE Project Description:INSTALLING GAS FURNACE AND GAS WATER HEATER. Owner: Adele Fazzone Address: 17714 31st Dr NE City:ARLINGTON State'.wA Zip Code: 98223 Phone: (425)698-9522 Email:delfazzone@live.com Applicant: NIKKI HYETT-SCHNELL Address:3909 196TH STSW City: LYNNWOOD State WA Zip Code: 98036 Phone: 206-378-6613 Email: NHYETT CONTRACTOR INFORMATION Contractor Name:WASHINGTON ENERGY SERVICES Address:3909 196TH STSW City: LYNNWOOD State WA Zip Code: 98036 License Number:WASHIES851NS Expiration: 09/07/2019 Phone:206-378-6613 Email:NHYETT- Received STAFF USE ONLY\ SUN 216 2019 Permit #�iL1) 2p�(J Accepted by:`'1`�� ��._ �� Date: 6/16LP Page 1 of 2 AN . RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #926TA3004OV14 AFUE96% Heat Pump Model # AFUE HSPE U� AC Unit Model # SEER ❑ Freestanding Stove II Fire Place Insert O' Outdoor BBQ ❑ Gas Piping Ll Solid-Fuel Appliance Lb Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: `" _ Date: 06/25/2019 Applicant Printed Name: NIKKI HYETT-SCHNELL I hereby'certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 Hello, We are installing a gas furnace 80/90 replacement.And a gas to gas water heater replacement. Please let me know if you have any other questions or concerns. Nikki Hyett-Schnell 206-378-6613 hmcoordinators@washinQ tone nergyxom ,� �. I S Search L&I . /• &'Industries o Workplace Rights Trades& Washington State Department of " Labor & Industries WASHINGTON ENERGY SVCS CO LLC Owner or tradesperson 3909196TH STREET SW Principals LYNNWOOD,WA 98036 OLSON,CRAIG E,PARTNER/MEMBER 206-282-4700 SNOHOMISH County OLSON,VERA A,PARTNER/MEMBER NG,YLIN-KWAN WINNIE,AGENT Doing business as WASHINGTON ENERGY SVCS CO LLC WA UBI No. Business type 603 522 032 Limited Liability Company Governing persons CRAIG E OLSON VERN A OLSON; CRAIG E OLSON; LLC FIRST POINT; Certifications & Endorsements License Verify the contractor's active registration/license 1 certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. WASHIES851 NS Effective—expiration 09/0712015—09/07/2019 Bond North American Spec Ins Co $12,000.00 Bond account no. 2198899 Received by L&I Effective date 08/10/2015 09/07/2015 Expiration date Until Canceled Insurance Peleus Insurance Company $1,000,000.00 Policy no. 103GL00191840 Received by L&I Effective date 07/31/2018 08/01/2018 Expiration date Help us improve 0810112019 Insurance history Savings ............. .. No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L$I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations Infraction no. PJONV04547 Satisfied Issue date RCW/WAC 11/02/2018 18.106.020 Violation city Violation amount LYNNWOOD $1,000.00 Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman,specialty or trainee certificate, temporary permit or medical gas endorsement as required.TOBIAS DOUGHERTY DISCONNECTING HOT WATER HEATERS WITHOUT CERTIFICATION. Infraction no. PPEJP01008 Satisfied Issue date RCW/WAC 08/22/2018 18.106.020 Violation city Violation amount LYNNWOOD $1,000.00 Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman,specialty or trainee certificate, temporary permit or medical gas endorsement as required. Infraction no. PBUJD00664 Satisfied Issue date RCW/WAC 04/12/2017 18.106.020 Violation city Violation amount LYNNWOOD $500.00 Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman,specialty or trainee certificate, temporary permit or medical gas endorsement as required.Contractor employed Patrick Michaelson to install a new gas hot water heater. Infraction no. PBUJD00665 Satisfied Issue date RCW/WAC 04/12/2017 18.106.020 Violation city Violation amount LYNNWOOD $500.00 Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman,specialty or trainee certificate, temporary permit or medical gas endorsement as required.Contractor employed Mario Valencia to install a new gas hot water heater. Infraction no. PZETD00865 Satisfied Issue date RCW/WAC 05/06/2016 18.106.020 Violation city Violation amount LYNNWOOD $250.00 Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman,specialty or trainee certificate, temporary permit or medical gas endorsement as required.Danny H Padilla Workers' comp Public Works Requirements Workplace safety and health "Access �!1'�sl�ingtoni0 Hel e us improve Hello, We are installing a gas furnace 80/90 replacement. And a gas to gas water heater replacement. Please let me know if you have any other questions or concerns. Nikki Hyett-Schnell 206-378-6613 hmcoordinators@washingtonenergy.com RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 17714 31st Dr NE Project Description:INSTALLING GAS FURNACE AND GAS WATER HEATER. Owner: Adele Fazzone Address. 17714 31st Dr NE City. ARLINGTON State.WA Zip Code: 98223 Phone: (425)698-9522 Email:delfazzone@live.com Applicant: NIKKI HYETT-SCHNELL Address: 3909 196TH ST SW City. LYNNWOOD State.WA Zip Code: 98036 Phone. 206-378-6613 Email. NHYETT- CONTRACTOR INFORMATION Contractor Name:WASHINGTON ENERGYSERVICES Address: 3909 196TH STSW City: LYNNWOOD State.WA Zip Code: 98036 License Number:WASHIES851NS Expiration: 09/07/2019 Phone: 206-378-6613 Email:NHYETT- STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #926TA3004OV14 AFUE 96% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances k� Applicant Signature: a6a92O�bB1'bOf6' Date: 06/25/2019 Applicant Printed Name: NIKKI HYETT-SCHNELL I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 NOTICE TO PERMITEE AND/OR OWNER Q PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY XAPPROVED P ERMIT#: LOT#: DATE: 7 ZS c j JOB ADDRESS: '-1-7 1 Ll TYPE OF INSPECTION: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK: MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION �4-r- THEACTIONS OR CORRECTIONS INDICATED ABOVEARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 a `G INSPECTOR DATE ( BUILDING DEPT. 0 PLANNING DEPT. CITY OF ARLINGTON 4 CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:17714 31st Dr NE Permit#:2630 Parcel#:00621300002600 Valuation:0.00 OWNER r APPLICANT * CONTRACTOR Name:BLACKBURN PROPERTIES LLC Name:Washington Energy Services Name:WASHINGTON ENERGY SERVICES Address:PO BOX 789 Address:3909 196th St SW Address:3909 196th Street SW City,State Zip:BURLINGTON,WA 98233 City,State Zip:Lynnwood,WA 98036 City,State Zip:Lynnwood,WA 98036 Phone: Phone:206-378-6613 Phone:800-398-4663 LIC: EXP: MECHANICAL CONTRACTOR = PLUMBING CONTRACTOR- Name:Washington Energy Services Name: Address:3909 196th St SW Address: City,State,Zip:Lynnwood,WA 98036 City,State,Zip: Phone:800-398-4663 Phone: LIC#:WASHIES85INS EXP: 09/07/2019 LIC#: EXP: JOB DESCRIPTION V PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and co e City on#3101. NIKKI HYETT-SCHNELL 07/23/2019 rLQ2 6/25/19 Si+tt&e Print Name Date Rdeased By Date CONDITIONS Adhere to approved appliance. Call for inspections. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 6/25/2019 Furnace $25.00 6/25/2019 Mechanical Permit Base Fee $25.00 6/25/2019 Processing/Technology Fee $25.00 6/25/2019 Water Heater $25.00 Total Due: $100.00 Total Payment: $0.00 Balance Due: $100.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon / / / ' TWO-STAGE 4-WAY ♦ E , VARIABLE SPEED I CONDENSING ♦ FURNACE, SERIES Product Data cabinet airflow leakage. • Quiet operation.Compare for yourself at HVACpartners.com. 0 • Ideal height 35"(889 mm)cabinet:short enough for taller coils, but still allows enough room for service. O • Silicon Nitride Perfect Light is Hot Surface Igniter. • SmartEvap is technology helps control humidity levels in the 0 home when used with a compatible humidity control system. • FanOn Plus""technology allows control of continuous fan speed p from a compatible thermostat. • 4-way multipoise design for upflow,downflow or horizontal 4 ® installations,with unique vent elbow and optional through- the-cabinet downflow venting capability. • Full-featured variable-speed blower motor,two-speed inducer motor,and two-stage gas valve. • Self-diagnostics. • Adjustable blower speed for cooling,continuous fan,and dehumidification. Al1264 • Aluminized-steel primary heat exchanger. The 926TA Multipoise Variable-Speed Condensing Gas Furnace . Stainless-steel condensing secondary heat exchanger. features the two-stage Preferred' Series System. The Perfect Heat® technology two-stage gas valve is at the heart of the ' Propane convertible(See Accessory list). comfort provided by this furnace, along with the variable-speed • Factory-configured ready for upflow applications. ECM blower motor, and two-speed inducer motor. With an • Fully-insulated casing including blower section. Annual Fuel Utilization Efficiency (AFUE) up to 96.5%, the . Convenient Air Purifier and Humidifier connections. Preferred- Series two-stage gas furnace provides exceptional . Direct-vent/sealed combustion,single-pipe venting or savings as well when compared to standard gas furnaces. This Preferred- Series Gas Furnace also features 4-way multipoise ventilated combustion air. installation flexibility, and is available in eight model sizes. The • Installation flexibility: sidewall or vertical vent. 926TA can be vented for direct vent/two-pipe, ventilated • Residential installations may be eligible for consumer financing combustion air, or single-pipe applications. All units meet through the Retail Credit Program. California Air Quality Management District emission requirements. All sizes are design certified in Canada. • Certified to leak 2%or less of nominal air conditioning CFM STANDARD FEATURES delivered when pressurized to 1-in.water column with all • All sizes meet ENERGY STAR®Version 4.0 criteria for gas present air inlets,air outlets,and condensate drain port(s)sealed. furnaces:95+AFUE;AMACF electrical rating;2%or less ect y Always Ask For QytE Pdfi Use of the AHRI Certified rnn Mark indicates a ]'l1�y�]1/]�''r Preferred' sn A ]]o];vw q manufacturer's participation in the program. For ]1] 1D' 'b, ri \o� CERTIFIED verification of certification for individual products, , ]�1�]i]S ilt HNC go to www.ahridirectory.org. IS0 9001 1 CASING RATED HEATING OUTPUTt DIMENSIONS HEATING AIRFLOW COOLING MOTOR HP- SAP ORDERING (IN.) (BTUH) CFM @ 0.5 SPEED NO. CFM#(High CFM (Low High Heating ESP (VARIABLE H D W High Low AFUE Heating Heating) ESP (In.W.C.) SPEED) (in.W.C.) 926TA3004OV14 35 29.5 14.2 39,000 25,000 96.5% 815 660 0.10 905 1/2 926TA3604OV17 35 29.5 17.5 39,000 25,000 96.0% 860 660 0.10 1065 1/2 926TA3606OV14 35 29.5 14.2 58,000 38,000 95.0% 1120 910 0.12 1065 1/2 926TA4206OV17 35 29.5 17.5 58,000 38,000 96.3% 1135 860 0.12 1475 3/4 926TA4808OV17 35 29.5 17.5 78,000 50,000 96.2% 1505 1160 0.15 1610 3/4 926TA6008OV21 35 29.5 21.0 78,000 51,000 96.5% 1555 1200 0.15 2005 1 926TA6010OV21 35 29.5 21.0 97,000 63,000 96.1% 1865 1435 0.20 2005 1 926TA6612OV24 35 1 29.5 1 24.0 1 117,000 76,000 1 96.5% 2375 1 1675 0.20 2115 1 tCapacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate. *Minimum heat CFM when low-heat rise adjustment switch(SW 1-3)and comfort/efficiency adjustment switch(SW1-4)on control center are OFF. ESP-External Static Pressure FEATURES AND BENEFITS Perfect Heat®Technology-This feature with Adaptive Control Reliable Heat Exchanger Design-The aluminized steel, clam is a proprietary function that promotes homeowner comfort shell primary heat exchanger was re-engineered to achieve greater through two stages of heating. This Bryant furnace offers a efficiency out of a smaller size. The first two passes of the heat patented algorithm that continually monitors and adjusts furnace exchanger are based on the current 80% product, a design with operation by looking at both current and past conditions to more than ten years of field-proven performance and success. determine the most effective stage of heating and the amount of These innovations, paired with the continuation of a crimped, time to run each stage,every cycle. no-weld seam create an efficient, robust design for this essential SmartEvap- Technology - When paired with a compatible component. thermostat, this dehumidification feature overrides the cooling The condensing heat exchanger, a stainless steel fin and tube blower off-delay when there is a call for dehumidification. By design, is positioned in the furnace to extract additional heat. deactivating the blower off-delay, SmartEvap technology prevents Stainless steel coupling box componentry between heat exchangers condensate that remains on the coil after a dehumidification cycle has exceptional corrosion resistance in both natural gas and from re-humidifying throughout the home.This results in reduced propane applications. humidity and a more comfortable indoor environment for the Optional Media Filter Cabinet-Enhanced indoor air quality in homeowner. the home is made easier with our media filter cabinet When Unlike competitive systems,SmartEvap technology only overrides installed as a part of the system, this cabinet allows for easy and the cooling blower off delay when humidity control is needed. convenient addition of a Bryant high efficiency air filter. Once humidity is back in control, SmartEvap re-enables the 4-Way Multipoise Design - One model for all applications - energy-saving cooling blower off-delay. there is no need to stock special downflow or horizontal models Fan On Plus' Technology-Sometimes the constant fan setting when one unit will do it all. The new heat exchanger design allows on a standard furnace system can actually reduce homeowner these units to achieve the certified AFUE in all positions. comfort by providing too much or too little air! Fan On Plus Direct or Single-pipe Venting, or Optional Ventilated technology improves comfort all year long by allowing the Combustion Air - This furnace can be installed as a 2-pipe homeowner to select the continuous fan speed of their choice using (Direct Vent) furnace, in an optional ventilated combustion air a compatible thermostat. application, or in single-pipe, non-direct vent applications. This HYBRID HEAT®Dual Fuel system-This system can provide provides added flexibility to meet diverse installation needs. more control over your monthly energy bills by automatically Sealed Combustion System-This furnace brings in combustion selecting the most economical method of heating. With HYBRID air from outside the furnace, which results in especially quiet HEAT,our system automatically switches between the gas furnace operation. By sealing the entire combustion vestibule, the entire and the electric heat pump as outside temperatures change to furnace can be made quieter,not just the burners. maintain greater efficiency and comfort than with any traditional Insulated Casing - Foil-faced insulation in heat exchanger single-source heating system. The heat pump also delivers section of the casing minimizes heat loss.The acoustical insulation high-efficiency cooling in the summer. in the blower compartment reduces air and motor noise for quiet Power Heat" Igniter-Bryant's unique SiN igniter is not only operation. physically robust but it is also electrically robust. It is capable of Monoport Burners - The burners are specially designed and running at line voltage and does not require complex voltage finely tuned for smooth, quiet combustion and economical regulators as do other brands.This unique feature further enhances operation. the gas furnace reliability and continues Bryant's tradition of technology leadership and innovation in providing a reliable and Bottom Closure - Factory-installed for side return; easily durable product. removable for bottom return. The multi-use bottom closure can also serve for roll-out protection in horizontal applications,and act Full-Featured, Variable Speed Motors - Our variable-speed as the bottom closure for the optional return air base accessory. ECM(Electronically Commutated Motor)optimizes comfort levels in the home year round; features such as passive/active Certifications - This furnace is CSA (AGA and CGA) design dehumidification,ramping profiles, and quiet operation. They can certified for use with natural and propane gases. The furnace is provide cooling match enhancements to increase the effective factory-shipped for use with natural gas. A CSA listed gas SEER of select Bryant air conditioner or heat pump system. This conversion kit is required to convert furnace for use with propane motor does not report back RPM and static pressure to enable static gas.The efficiency is AHRI efficiency rating certified.This furnace pressure reporting to the UI or zoning system,which is required for meets California Air Quality Management District emission zoning, active filter monitoring and system static pressure requirements. reporting. 2 MODEL NUMBER NOMENCLATURE Example of a Model Number 1-2 3 4 5 6-7 8-10 11 12-13 14 15 16 Family/Tier Base Eff. Htg.Stages Major Series Clg.Cap. Htg.Cap. Motor Width Voltage Features Minor Series 92 6 T A 30 040 V 14 A — A 91-Legacy 0-+90 AFUE 92-Preferred 2-+92 AFUE 3-+93 AFUE 98-EVOIUfIOn 5-+95 AFUE 6-+96AFUE 7-+97AFUE S-Single Stage T-Two Stage M-Modulating 24- 800 CFM 14-14 2=' 30-1000 CFM 17-17.5== L-Low NOx 36-1200 CFM 21-21.0== Voltage 42-1400 CFM 24-24.5= 48-1600 CFM 040=40,000 BTU Major Series 54-1800 CFM 060=60,000 BTU S-Standard 60-2000 CFM 080=80,000 BTU E-Energy Efficient 66-2200 CFM 100=100,000 BTU V-Variable Speed (@ 0.5'ESP) 120=120,000 BTU =140 000 BTU Not all familes have these models. A14367 FURNACE COMPONENTS HOTSURFACE GAS BURNER IGNITER MANUAL RESET ROLLOUT SWITCH FLAME O O SENSOR O O � MANUALRESET ROLLOUT SWITCH GAS VALVE • Q MAIN LIMIT SWITCH (BEHIND GAS VALVE) OPERATING INSTRUCTIONS • _ NOT SHOWN(LOCATED ON + lr MAIN FURNACE DOOR,SEE OPERATING INSTRUCTIONS •O I� INSIDE DOOR FIGURE). • O OINDUCER MOTOR ® ASSEMBLY ELECTRICAL JUNCTION O BOX(IF REQUIRED, ■� LOCATION MAY VARY) s• BLOWER DOOR ✓1! SAFETY SWITCH MEDIA CABINET ID FURNACE BLOWER AND CONTROL ! I MOTOR BOARD ®0 CAPACITOR/ POWER CHOKE (IF USED) RATING PLATE NOT SHOWN (LOCATED ON BLOWER DOOR) REPRESENTATIVE DRAWING ONLY,SOME MODELS MAY VARY IN APPEARANCE. A11408 3 SPECIFICATIONS The furnace should be sized to provide 100 percent of the design method to calculate heating load estimates and select the furnace. heating load requirement plus any margin that occurs because of Excessive oversizing of the furnace may cause the furnace and/or furnace model size capacity increments. None of the furnace vent to fail prematurely,customer discomfort and/or vent freezing. model sizes can be used if the heating load is 20,000 BTU or Failure to follow these guidelines is considered faulty installation lower. Use Air Conditioning Contractors of America (Manual J and/or misapplication of the furnace;and resulting failure,damage, and S); American Society of Heating, Refrigerating, and or repairs may impact warranty coverage. Air-Conditioning Engineers; or other approved engineering Heating Capacity and Efficiency 30040 36040 36060 42060 48080 60080 60100 66120 Input High Heat (BTUH) 40,000 40,000 60,000 60,000 80,000 80,000 100,000 120,000 Low Heat (BTUH) 26,000 26,000 39,000 39,000 52,000 52,000 65,000 78,000 Output High Heat (BTUH) 39,000 39,000 58,000 58,000 78,000 78,000 97,000 117,000 Low Heat (BTUH) 25,000 25,000 38,000 38,000 50,000 51,000 63,000 76,000 High Heat 40-70 40-70 40-70 40-70 40-70 40-70 40-70 40-70 Certified Temperature (22-39) (22-39) (22-39) (22-39) (22-39) (22-39) (22-39) (22-39) Rise Range IF(IC) Low Heat 30-60 30-60 30-60 30-60 30-60 30-60 30-60 30-60 (17-33) (17-33) (17-33) (17-33) (17-33) (17-33) (17-33) (17-33) Airflow Capacity and Blower Data 30040 36040 36060 42060 48080 60080 60100 66120 Rated External Static Heating 0.10 0.10 0.12 0.12 0.15 0.15 0.20 0.20 Pressure(in.w.c.) Cooling 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 High Heat 815 860 1120 1135 1505 1555 1865 2375 Airflow Delivery @ Rated ESP(CFM) Low Heat 660 660 910 860 1160 1200 1435 1675 Cooling 905 1065 1065 1475 1610 2005 2005 2115 Cooling Capacity(tons) 400 CFM/ton 2 2.5 2.5 3.5 4 5 5 5 @ 400,350 CFM/ton 350 CFM/ton 2.5 3 3 4 4.5 5.5 5.5 6 Direct-Drive Motor Type Electronically Communicated Motor(ECM) Direct-Drive Motor HP 1/2 1/2 1/2 /4 3/4 1 1 1 Motor Full Load Amps 6.8 6.8 6.8 8.4 8.4 10.9 10.9 10.9 RPM Range 600-1200 Speed Selections Variable(PWM) Blower Wheel Dia x Width in. 11 x 7 11 x 8 11 x 7 11 x 8 11 x 8 11 x 10 11 x 10 11 x 11 Air Filtration System Optional Media Cabinet Field Supplied Filter Filter Used for Certified Waft Data KGAWF1506UFR Electrical Data 30040 36040 36060 42060 48080 60080 60100 66120 Input Voltage Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104-127 Maximum Input Amps Amps 7.5 7.5 7.6 9.2 9.2 11.7 11.8 11.8 Unit Ampacity Amps 10.3 10.2 10.3 12.4 12.4 15.5 15.6 15.6 Minimum Wire Size AWG 14 14 14 14 14 12 12 12 Maximum Wire Length Feet 36 36 36 29 29 37 36 36 @ Minimum Wire Size (M) (11.0) (11.0) (11.0) (8.8) (8.8) (11.3) (11.0) (11.0) Maximum Fuse/Ckt Bkr Amps 15 15 15 15 15 20 20 20 (Time-Delay Type Recommended) Transformer Capacity(24vac output) VA External Control Power Heating .3 VA Available Cooling .6 VA Controls 30040 36040 36060 42060 48080 60080 60100 66120 Gas Connection Size 1/2"-NPT Burners(Monoport) 2 2 3 3 4 4 5 6 Gas Valve(Redundant) Manufacturer White Rodgers Minimum Inlet Gas pressure(in.we) 4.5 Maximum Inlet Gas pressure(in.wc) 13.6 Manufactured(Mobile)Home Kit not approved for MH use Ignition Device Silicon Nitride Limit Control 165 180 165 180 170 200 180 160 Heating Blower Control(Heating Off-Delay) Adjustable:90, 120, 150, 180 seconds Cooling Blower Control(Time Delay Relay) 90 seconds Communication System None Thermostat Connections R,W/W1,W2 Y/Y2,Y1,G,Com 24V,DHUM Accessory Connections EAC(115vac);HUM(24vac); 1-stg AC(via Y/Y2) * See Accessory List for part numbers available. 4 ACCESSORIES DESCRIPTION PART NUMBER 30040 36040 36060 42060 48080 60080 60100 66120 Venting Accessories Vent Kit-Through the Cabinet KGADC0101 BVC • • • • • • • • Vent Terminal-Concentric-2"(51 mm) KGAVT0701 CVT Vent Terminal-Concentric-3"(76 mm) KGAVTO801 CVT Vent Terminal Bracket-2"(51 mm) KGAVTO101 BRA See Venting Tables Vent Terminal Bracket-3"(76 mm) KGAVT0201 BRA Vent Kit—Rubber Coupling KGAAC0101 RVC See Venting Tables Condensate Drainage Accessories Freeze Protect Kit-Heat Tape KGAHT0101 CFP • • • • • • • • CPVC to PVC Drain Adapters-1/2"CPVC to 3/4"PVC KGAAD0110PVC • • • • • • • • Horizontal Trap Grommet-Direct Vent KGACK0101 HCK All DV Horizontal Condensate Neutralizer Kit P908-0001 • • • • • • • • External Trap Kit KGAET0201 ETK • • • • • • • • Ductwork Adapter Accessories Furnace Base Kit for Combustible Floors KGASB0201ALL • • • • • • • • Coil Adapter Kits—No Offset KGADA0101ALL • • • • • • • • Coil Adapter Kits—Single Offset KGADA0201ALL • • • • • • • • Coil Adapter Kits—Double Offset KGADA0301ALL • • • • • • • • Return Air Base(Upflow Applications)14.0—in.wide KGARP0301 B14 • • Return Air Base(Upflow Applications)17.5—in.wide KGARP0301 B17 • • • Return Air Base(Upflow Applications)21.0—in.wide KGARP0301 B21 • • Return Air Base(Upflow Applications)24.5—in.wide KGARP0301 B24 • IAQ Device Duct Adapters 20.0—in.IAQ to 16 in.Side KGAAD0101 MEC 20"x25"IAQ Devices Return IAQ Device Duct Adapters 24.0—in.IAQ to 16 in.Side KGAAD0201 MEC 24"x25"IAQ Devices Return Gas Conversion Accessories Gas Conversion Kit-Nat to LP;Var-speed Products KGCNP5201 VSP • • • • • • • • Gas Conversion Kit-LP to Nat;Var-speed Products KGCPN4401 VSP • • • • • • • • Gas Orifice Kit-#42(Nat Gas) LH32DB207 • • • • • • • • Gas Orifice Kit-#43(Nat Gas) LH32DB202 • • • • • • • • Gas Orifice Kit-#44(Nat Gas) LH32DB200 • • • • • • • • Gas Orifice Kit-#45(Nat Gas) LH32DB205 • • • • • • • • Gas Orifice Kit-#46(Nat Gas) LH32DB208 • • • • • • • • Gas Orifice Kit-#47(Nat Gas) LH32DBO78 • • • • • • • • Gas Orifice Kit-#48(Nat Gas) LH32DBO76 • • • • • • • • Gas Orifice Kit-#54(LP) LH32DB203 • • • • • • • • Gas Orifice Kit-#55(LP) LH32DB201 • • • • • • • • Gas Orifice Kit-#56(LP) LH32DB206 • • • • • • • • Gas Orifice Kit-1.25mm(LP) LH32DB209 • • • • • • • • Gas Orifice Kit-1.30mm(LP) LH32DB210 • • • • • • • • Control Accessories Advanced Product Monitor-APM KGASD0301 APM • • • • • • • • Preferred'"Series Thermidistat T6—PRH • • • • • • • • Twinning Kit KGATW0801HSI • • • • IAQ Accessories Filter Pack(6 pack)—Washable-16x25x1 KGAWF1306UFR • • • • • • • • (406x635x25 mm) Filter Pack(6 pack)—Washable-24x25x1 KGAWF1506UFR • • • • • • • • (610x635x25 mm) EZ-Flex Filter-16"(406 mm) EXPXXFIL0016 Use with EZXCAB-1016 EZ-Flex Filter-20"(508 mm) EXPXXFIL0020 Use with EZXCAB-1020 EZ-Flex Filter-24" (610 mm) EXPXXFIL0024 Use with EZXCAB-1024 EZ-Flex Filter with End Caps-16"(406 mm) EXPXXUNVO016 Use with EZXCAB-1016 EZ-Flex Filter with End Caps-20"(508 mm) EXPXXUNVO020 Use with EZXCAB-1020 EZ-Flex Filter with End Caps-24"(610 mm) EXPXXUNVO024 Use with EZXCAB-1024 Cartridge Media Filter-16"(406 mm) FILXXCAR0016 Use with FILCABXL-1016 Cartridge Media Filter-20"(508 mm) FILXXCAR0020 Use with FILCABXL-1020 Cartridge Media Filter-24"(610 mm) FILXXCAR0024 Use with FILCABXL-1024 Bryant Perfect Air Purifier-16x25(406x635 mm) GAPAAX13131625-A08 Up to 1600 CFM Bryant Perfect Air Purifier-20x25 (508x635 mm) GAPAAXBB2025-A08 Up to 2000 CFM Bryant Perfect Air Purifier Repl.Filter-16x25 GAPABBCAR1625-A05 Use with GAPAAXBB1625 (406x635 mm) Bryant Perfect Air Purifier Repl.Filter-20x25 GAPABBCAR2025-A05 Use with GAPAAXBB2025 (508x635 mm) Bryant Preferred Air Purifier-16x25(508x635 mm) PGAPXX1625 Up to 1600 CFM Bryant Preferred Air Purifier-20x25(508x635 mm) PGAPXX2025 Up to 2000 CFM Bryant Preferred Air Purifier Repl Filter-16x25 PGAPAXXCAR1625 Use with PGAPXX1625 (406x635 mm) Bryant Preferred Air Purifier Repl.Filter-20x25 PGAPAXXCAR2025 Use with PGAPXX2025 (508x635 mm) •=Used with the model furnace 5 AIR DELIVERY - CFM (SWi-5 and SW2-2 set to OFF,except as indicated.See notes 1 and 2) Unit Size Cooling Switch Settings External Static Pressure ESP SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.030 30040 Clq Default: OFF OFF OFF 1125 1080 1020 970 905 855 805 755 700 635 OFF OFF ON 615 555 510 475 440 395 355 270 230 note 8 OFF ON OFF 785 740 695 665 630 590 565 520 485 450 OFF ON ON 990 950 910 875 850 815 770 720 670 615 Cooling (SW2) ON OFF OFF 1125 1080 1020 970 905 855 805 755 700 635 ON OFF ON 1125 1080 1020 970 905 855 805 755 700 635 ON ON OFF 1125 1080 1020 970 905 855 805 755 700 635 ON ON ON 1125 1080 1020 970 905 855 805 755 700 635 Cig SW2: Maximum C1g Airflow 2 1125 1080 1020 970 905 855 805 755 700 635 High Heat Airflow 3 815 770 725 695 660 625 595 550 510 475 Heating (SWi) Low Heat Airflow 660 605 560 530 495 450 415 340 300 Note 7 36040 Cbq Default: OFF OFF OFF 1250 1210 1165 1115 1065 1015 965 915 860 810 OFF OFF ON 575 540 490 435 385 See note 4 OFF ON OFF 770 725 685 640 600 560 515 480 See note 4 OFF ON ON 945 910 875 835 800 770 735 695 665 635 Cooling (SW2) ON OFF OFF 1140 1105 1075 1040 1005 970 930 885 835 790 ON OFF ON 1250 1210 1165 1115 1065 1015 965 915 860 810 ON ON OFF 1250 1210 1165 1115 1065 1015 965 915 860 810 ON ON ON 1250 1210 1165 1115 1065 1015 965 915 860 810 Clg SW2: Maximum C1g Airflow 2 1250 1210 1165 1115 1065 1015 965 915 860 810 High Heat Airflow 860 825 785 745 705 670 630 595 565 525 Heating (SWi) Low Heat Airflow 650 595 545 500 460 415 365 320 275 note 7 36060 Cbq Default: OFF OFF OFF 1250 1210 1165 1115 1065 1015 955 895 815 745 OFF OFF ON 605 565 510 455 420 See note 4 OFF ON OFF 785 750 705 675 630 585 See note 4 OFF ON ON 955 920 895 860 825 785 755 720 685 650 Cooling (SW2) ON OFF OFF 1135 1110 1080 1055 1020 990 935 880 825 745 ON OFF ON 1250 1210 1165 1115 1065 1015 955 895 815 745 ON ON OFF 1250 1210 1165 1115 1065 1015 955 895 815 745 ON ON ON 1250 1210 1165 1115 1065 1015 955 895 815 745 Clg SW2: Maximum C1g Airflow 2 1250 1210 1165 1115 1065 1015 955 895 815 745 High Heat Airflow 1125 1100 1070 1045 1010 980 925 875 820 740 Heating (SWi) Low Heat Airflow 900 865 835 800 760 720 690 650 610 580 6 AIR DELIVERY - CFM (CONTINUED) Unit Size Coolin Switch Settin s External Static Pressure ESP SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 42060 Cig Default: OFF OFF OFF 1330 1295 1260 1220 1190 1150 1110 1075 1045 1005 OFF OFF ON 725 660 600 520 435 See note 4 OFF ON OFF 780 725 660 615 540 See note 4 OFF ON ON 975 925 875 835 785 750 690 655 610 570 Cooling (SW2) ON OFF OFF 1160 1120 1090 1045 1010 970 920 885 840 800 ON OFF ON 1330 1295 1260 1220 1190 1150 1110 1075 1045 1005 ON ON OFF 1705 1650 1595 1545 1475 1415 1340 1275 1200 1105 ON ON ON 1705 1650 1595 1545 1475 1415 1340 1275 1200 1105 Clg SW2: Maximum C1g Airflow 2 1705 1650 1595 1545 1475 1415 1340 1275 1200 1105 High Heat Airflow 1145 1105 1075 1030 995 955 905 870 825 785 Heating (SWi) Low Heat Airflow 3 870 820 760 720 655 620 560 525 470 435 48080 Clq Default: OFF OFF OFF 1805 1765 1720 1665 1610 1540 1475 1400 1315 1235 OFF OFF ON 775 635 455 230 See note 8 OFF ON OFF 840 740 675 625 555 See note 4 OFF ON ON 995 955 910 860 815 770 720 660 620 585 Cooling (SW2) ON OFF OFF 1175 1140 1090 1060 1025 980 940 905 855 815 ON OFF ON 1325 1280 1245 1210 1180 1140 1105 1070 1025 990 ON ON OFF 1545 1515 1480 1445 1410 1380 1350 1315 1245 1175 ON ON ON 1805 1765 1720 1665 1610 1540 1475 1400 1315 1235 Clg SW2: Maximum C1g Airflow 2 1805 1765 1720 1665 1610 1540 1475 1400 1315 1235 High Heat Airflow 3 1520 1490 1455 1420 1 1385 1 1355 1320 1285 1220 11 1155 Heating (SWl) Low Heat Airflow 3 1180 1 1145 1 1095 1 1065 1030 985 1 945 1 910 860 820 60080 CI Default: OFF OFF OFF 1905 1870 1825 1785 1750 1700 1665 1625 1560 1460 OFF OFF ON 950 770 620 515 440 365 See note 4 OFF ON OFF 1015 935 880 825 765 690 625 580 See note 4 OFF ON ON 1155 1105 1040 990 920 875 815 755 710 645 Cooling (SW2) ON OFF OFF 1335 1290 1245 1190 1145 1085 1040 990 930 890 ON OFF ON 1520 1485 1435 1390 1340 1300 1255 1200 1160 1115 ON ON OFF 1905 1870 1825 1785 1750 1700 1665 1625 1560 1460 ON ON ON 2290 2230 2160 2085 2005 1915 1820 1730 1640 1525 Cl SW2: Maximum C1g Airflow 2 2290 2230 2160 2085 2005 1915 1820 1730 1640 1525 High Heat Airflow 1575 1535 1485 1445 1400 1350 1310 1260 1215 1170 Heating AL (SW1) Low Heat Airflow 1230 1170 1125 1065 1015 955 900 855 795 755 NOTE:See notes at end of table. 7 AIR DELIVERY - CFM (CONTINUED) Unit Size Coolin Switch Settin s External Static Pressure ESP SW2-8 SW2-7 SW2-6 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 60100 Cig Default: OFF OFF OFF 1890 1845 1800 1755 1700 1655 1610 1560 1510 1460 OFF OFF ON 1015 825 630 485 405 325 See note 4 OFF ON OFF 1080 895 815 740 690 615 555 475 See note 4 OFF ON ON 1155 1080 1020 940 890 825 785 710 660 590 Cooling (SW2) ON OFF OFF 1310 1260 1195 1140 1075 1025 970 925 875 810 ON OFF ON 1520 1475 1425 1365 1315 1255 1210 1155 1110 1055 ON ON OFF 1890 1845 1800 1755 1700 1655 1610 1560 1510 1460 ON ON ON 2290 2230 2160 2085 2005 1915 1820 1730 1640 1525 Clg SW2: Maximum Clg Airflow 2 2290 2230 2160 2085 2005 1915 1820 1730 1640 1525 High Heat Airflow 3 1905 1865 1825 1775 1730 1685 1640 1590 1545 1490 Heating (SWi) Low Heat Airflow 1480 1435 1375 1330 1265 1215 1160 1115 1060 1005 66120 Cig Default: OFF OFF OFF 2010 1960 1910 1850 1800 1750 1690 1645 1565 1480 OFF OFF ON 1015 805 645 550 480 See note 4 OFF ON OFF 1075 975 915 835 765 See note 4 OFF ON ON 1205 1135 1055 1000 935 See note 4 Cooling (SW2) ON OFF OFF 1400 1330 1260 1190 1145 1080 1035 970 905 845 ON OFF ON 1615 1550 1500 1435 1370 1325 1265 1215 1160 1110 ON ON OFF 2010 1960 1910 1850 1800 1750 1690 1645 1565 1480 ON ON ON note 8 2375 2300 2205 2115 2010 1890 1750 1645 1550 Clg SW2: Maximum Clg Airflow 2 note 8 2375 2300 2205 2115 2010 1890 1750 1645 1550 High Heat Airflow note 8 2375 2300 2205 2115 2010 1890 1750 1645 1550 Heating (SW1) Low Heat Airflow 1 1735 1 1675 1 1625 1560 1500 1455 1395 1345 1285 1225 1. Nominal 350 CFM/ton cooling airflow is delivered with SWi—5 and SW2-2 set to OFF. Set both SWi—5 and SW2-2 to ON for+7%airflow(nominal 370 CFM/ton). Set SWi—5 to ON and SW2-2 to OFF for+15%airflow(nominal 400 CFM/ton). Set SW2-2 to ON and SWi—5 to OFF for—7%airflow(nominal 325 CFM/ton). The above adjustments in airflow are subject to motor horsepower range/capacity. 2. Maximum cooling airflow is achieved when switches SW2-6,SW2-7,SW2-8 and SWi—5 are set to ON,and SW2-2 is set to OFF. 3. All heating CFM's are when low heat rise adjustment switch(SW1-3)and comfort/efficiency adjustment switch(SWi—4)are both set to OFF. 4. Ductwork must be sized for high—heating CFM within the operational range of ESP.Operation within the blank areas of the chart is not recommended because high—heat operation will be above 1.0 ESP. 5. All airflows of 1880 CFM or less on 21"and 24.5"casing size furnaces are 5%less on side return only installations. 6. Return air above 1800 CFM on 24.5"casing requires two sides,one side and bottom,or bottom only to allow sufficient airflow to the furnace. 7. For upflow applications,air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return. 8. Airflow not stable at this ESP. 8 MAXIMUM ALLOWABLE EXPOSED VENT LENGTH Table 1-Maximum Allowable Exposed Vent Lengths in Unconditioned Space Insulation Table-Ft. Unit Size 40,000 BTUH60,000 BTUH Uninsulated 3/8-in.Insulation 1/2-in.Insulation nmsu ate 3 8-in.Insulation 1 2-in.Insulation Winter Pipe Dia. 1% 2 2% 1% 2 2% 1% 2 2% 1% 2 2% 3 1% 2 2% 3 1% 2 2% 3 Design in. Temp 20 20 20 20 20 50 45 20 60 50 20 3 30 25 20 75 65 60 20 85 75 65 °F 0 10 5 5 20 25 20 20 30 25 15 5 0 10 20 40 30 25 20 45 40 30 -20 5 20 15 10 20 20 15 10 5 20 25 20 15 20 30 25 20 -40 15 10 5 5 15 10 5 20 15 15 10 20 20 15 10 Unit Size 80,000 BTUH Uninsulated 3/8-in.Insulation 1/2-in.Insulation Winter Pipe Dia. 1% 2 2% 3 4 1% 2 2% 3 4 1% 2 2% 3 4 Design in. Temp 20 15 40 40 35 30 15 50 90 75 65 15 50 70 70 70 °F 0 15 20 15 10 5 15 50 45 35 30 15 50 50 40 35 -20 15 10 5 15 35 30 20 15 15 40 30 25 15 -40 10 5 15 25 20 15 5 15 30 25 20 10 Unit Size 100,000 BTUH Uninsulated 3/8-in.Insulation 1/2-in.Insulation Winter Pipe Dia. 2 2% 3 4 2 2% 3 4 2 2% 3 4 Design in. Temp 20 20 50 40 35 20 80 95 80 20 80 105 90 °F 0 20 20 15 10 20 55 45 35 20 65 55 5 -20 15 10 5 20 35 30 20 20 5 35 25 -40 10 5 20 5 20 0 20 30 5 5 Unit Size 120,000 BTUH 140,000 BTUH Uninsulated 3/8-in.Insulation 1/2-in.Insulation Uninsulated 3 8-in.Insulation 1/2-in.Insulation Winter ripe Dia.Design in. 2% 3 4 2% 3 4 2% 3 4 2% 3 4 2% 3 4 2% 3 4 Temp 20 10 50 40 10 75 95 10 75 105 5 55 50 5 65 105 5 65 125 °F 0 10 20 5 10 55 5 10 65 5 5 25 5 5 65 50 5 65 6 -20 10 10 35 25 10 5 3 5 5 5 45 30 5 50 -40 10 5 10 25 5 10 3 5 5 5 30 0 5 35 25 Maximum Allowable Exposed Vent Length in Unconditioned Space- Meters Unit Size 0, 60,000 BTUH Uninsu ate 3/8-in.Insulation 1/2-in.Insulation Uninsulated 3/8-in.Insulation -In.Insulation Winter Pipe Dia. 38 51 64 38 51 64 38 51 64 38 51 64 76 38 51 64 76 38 51 64 76 Design mm Temp -7 6.1 6.1 6. 6.1 15.2 13.7 6.1 18.3 15.2 6.1 9.1 9.1 7.6 6.1 22.9 19.8 18.3 6.1 25.9 22.9 19.8 °C 1.5 1.5 6.1 7.6 6.1 6.1 9.1 7.6 4.6 4.6 3.0 3.0 6.1 12.2 9.1 7.6 6.1 13.7 12.2 9.1 -29 1.5 6.1 4.6 3.0 6.1 6.1 4.6 3.0 1.5 6. 7.6 6.1 4.6 6.1 9.1 7.6 6.1 0 4.6 3.0 .5 .6 4.6 3.0 1.5 6. 6 6 3.0 6. 6.1 4.6 3.0 Unit Size 80,000 BTUH Uninsulated 3 8-in.Insulation 1/2-in.Insulation Winter Pipe Dia. 38 51 64 76 102 38 51 64 76 102 38 51 64 76 102 Design mm Temp -7 4.6 12.2 12.2 10.7 9.1 4.6 15.2 27.4 22.9 19.8 4.6 15.2 21.3 21.3 21.3 °C -18 4.6 6.1 4.6 3.0 1.5 4.6 15.2 13.7 10.7 9. 4.6 15.2 J5.2 12.2 10.7 -29 4.6 3.0 1.5 4.6 0.7 9.1 6.1 4.6 4.6 12.2 9.1 7.6 4.6 0 3.0 .5 4.6 7.6 6.1 4.6 1.5 4.6 9.1 7.6 6. 3.0 Unit Size 100,000 BTUH Uninsulated 3/8-in.Insulation 1/2-in.Insulation Winter ripe Dia. 51 64 76 102 51 64 76 102 51 64 76 102 Design mm Temp -7 6.1 15.2 12.2 10.7 6.1 2 28.9 24.4 6.1 24.4 32.0 27. °c 6.8 3.7 10.7 6.1 19.8 16.7 3.7 -29 4.6 3. 1.5 6.1 10.7 9. 6. 6. 3.7 10.7 7.6 0 3.0 .5 6.1 7.6 6. 3.0 6. 9.1 Unit Size 120,000 BTUH 140,000 BTUH Uninsulated 3/8-in.Insulation 1/2-in.Insulation Uninsulated 3 8-in.Insulation 1/2-in.Insulation Winter ripe Dia. 64 76 102 64 76 102 64 76 102 64 76 102 64 76 102 64 76 102 Design mm Temp -7 3.0 15.2 12.2 3.0 22.9 28.9 3.0 22.9 32.0 1.5 16.7 15.2 1.5 19.8 32.0 1.5 19.8 38.1 °c 8 3.0 6. 4.6 3.0 6.8 13.7 3.0 9.8 5.2 1.5 7.6 4.6 .5 19.8 5.2 1.5 19.8 18.3 -29 3.0 3.0 3.0 10.7 7.6 3.0 13.7 9.1 1.5 3.0 .5 .5 13.7 9.1 1.5 15.2 12.2 0 3.0 .5 3.0 7.6 .6 3.0 9.1 6.1 1.5 .5 .5 9.1 6.1 1.5 35 7.6 *Pipe length(ft)specified for maximum pipe lengths located in unconditioned spaces.Pipes located in unconditioned space cannot exceed total allowable pipe length calculated from Table 2. t Insulation thickness based on R value of 3.5 per in. 9 MAXIMUM EQUIVALENT VENT LENGTH - FT. (M) NOTE: Maximum Equivalent Vent Length(MEVL)includes standard and concentric vent termination and does NOT include elbows. Use Table 3 -Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application. Table 2-Maximum Equivalent Vent Length -Ft. 40,000 Unit Size Outlet choke 60,000 80,000 100,000 120,000 140,000 required under 10 ft.TEVL Pipe Dia.(in) 1% 2 2% 1% 2 2% 3 1% 2 2% 3 4 2 2% 3 4 2% 3 4 2% 3 4 0-2000 40 155 185 100 175 200 15 50 130 175 200 20 80 175 200 75 185 5 65 155 2001-3000 35 150 175 20 95 165 185 45 125 165 185 15 75 165 185 10 70 175 60 140 3001-4000 30 135 160 90 155 175 115 155 175 175 5 65 165 120 w 4001-4500 25 130 155 15 85 150 170 10 40 110 150 165 70 155 170 1 50 110 60 y 4501-5000 125 145 80 165 145 160 150 165 60 45 100 5001-6000 20 120 130 75 140 155 35 100 135 150 10 65 140 155 155 /A 35 80 Q 6001-7000 15 110 120 10 70 130 t45 30 90 125 140 60 135 145 N/A 50 140 30 65 7001-8000 10 100 110 65 120 N/A 120 125 55 125 135 45 130 25 45 8001-9000 90 95 5 60 115 25 80 110 115 50 115 125 40 120 15 30 9001-10000 5 80 85 55 105 20 75 100 105 45 100 115 30 115 10 15 Meters/MM Maximum Equivalent Vent Length -Meters 40,000 Unit Size Outlet choke 60,000 80,000 100,000 120,000 140,000 required under 10 ft.TEVL Pipe Dia. 38 51 64 38 51 64 76 38 51 64 76 102 51 64 76 102 64 76 102 64 76 102 (mm) 0-610 11 57 57 31 54 61 3 F1640 54 61 6 25 54 61 23 57 1.5 21 48 611-914 10 53 53 6.5 29 51 57 38 51 57 5 23 51 57 3 21 54 18 42 915-1219 9 49 49 27 48 54 36 48 53 48 54 1.5 20 51 36 E 1220-1370 47 47 26 52 2 46 51 22 52 16 33 0 1371-1524 8 45 45 5 24 46 51 34 45 50 21 46 51 19 50 1431 1525-1829 6 41 41 22 43 47 31 42 46 3 43 48 48 N/A 11 25 Q 1830-2134 5 37 37 3 25 40 44 10 27 39 42 19 41 45 N/A 16 43 9 20 2135-2438 33 34 20 37 42 36 39 18 38 42 14 40 7 15 2439-2743 3.5 30 30 1.5 19 35 38 N/A 8 26 34 36 N/A 15 36 39 13 38 5 10 2744-3048 1.5 26 26 N/A 17 33 36 7 24 31 33 14 34 36 12 �35 3.5 5 ELBOW CONFIGURATIONS VENTTERMINAL CONFIGURATIONS Concentric Long Medium Mitered _ Standard 2-in.,3-in.,or optional 4-in.termination. A13110 Table 3-Deductions from Maximum Equivalent Vent Length-Ft.(M) Pipe Diameter(in): 1-1/2 2 2-1/2 3 4 Mitered 900 Elbow 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4) Medium Radius 900 Elbow 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) Long Radius 900 Elbow 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) Mitered 450 Elbow 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) Medium Radius 450 Elbow 2.5 (0.8) 2.5 (0.8) 2.5 (0.8) 2.5 (0.8) 2.5 (0.8) Long Radius 450 Elbow 1.5 (0.5) 1.5 (0.5) 1.5 (0.5) 1.5 (0.5) 1.5 (0.5) Tee 16 (4.9) 16 (4.9) 16 (4.9) 16 (4.9) 16 (4.9) Concentric Vent Termination NA 0 (0.0) NA 0 (0.0) NA Standard Vent Termination 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 10 Venting System Length Calculations The Total Equivalent Vent Length('I EVL)for EACH combustion air or vent pipe equals the length of the venting system,plus the equivalent length of elbows used in the venting system from Table 3. Standard vent terminations or factory accessory concentric vent terminations count for zero deduction. See vent system manufacturer's data for equivalent lengths of flexible vent pipe or other termination systems. DO NOT ASSUME that one foot of flexible vent pipe equals one foot of straight PVC/ABS DWV vent pipe. Compare the Total Equivalent Vent Length to the Maximum Equivalent Vent Lengths in Table 2. Example 1 A direct-vent 60,000 Btuh furnace installed at 2100 ft.(640 M). Venting system includes,FOR EACH PIPE,100 feet(30 M)of vent pipe, 95 feet(28 M)of combustion air inlet pipe,(3)90' long radius elbows,(2)45' long radius elbows and a factory accessory concentric vent kit. Can this application use 2-in.(50 mm ND)PVC/ABS DWV vent piping? Measure the required linear length of air inlet and vent pipe;insert the 100 ft Use length of the longer of the vent longest of the two here: or air inlet piping system Add equiv length of (3)900 long-radius elbows (use the highest number of elbows for either the 3 x 3 ft = 9 ft. From Table 3 vent or inlet pipe) Add equiv length of (2)450 long-radius elbows (use the highest number of elbows for either the 2 x 1.5 ft = 3 ft. From Table 3 vent or inlet pipe) Add equiv length of vent termination 0 ft. From Table 3 Add correction for flexible vent pipe,if any 0 ft. From Vent Manufacturer's instructions; zero for PVC/ABS DWV Total Equivalent Vent Length(TEVL) 112 ft. Add all of the above lines Maximum Equivalent Vent Length(MEVL) 127 ft. For 2"pipe from Table 2 Is TEVL less than MEVL? YES Therefore,2"pipe may be used Example 2 A direct-vent 60,000 Btuh furnace installed at 2100 ft.(640 M) Venting system includes,FOR EACH PIPE,100 feet(30 M)of vent pipe, 95 feet(28 M)of combustion air inlet pipe,(3)90' long radius elbows,and a polypropylene concentric vent kit. Also includes 20 feet(6 M) of flexible polypropylene vent pipe,included within the 100 feet(30 M)of vent pipe. Assume that one meter of flexible 60 mm or 80 mm polypropylene pipe equals 1.8 meters of PVC/ABS pipe. VERIFY FROM VENT MANUFACTURER'S INSTRUCTIONS. Can this application use 60 mm(O.D.)polypropylene vent piping? If not what size piping can be used? Measure the required linear length of air inlet and vent pipe;insert the 100 ft Use length of the longer of the vent longest of the two here: or air inlet piping system Add equiv length of (3)900 long-radius elbows (use the highest number of elbows for either the 3 x 3 ft = 9 ft. From Vent Manufacturer's instructions vent or inlet pipe) Add equiv length of (2)450 long-radius elbows (use the highest number of elbows for either the 0 x = 0 ft. From Vent Manufacturer's instructions vent or inlet pipe) Add equiv length of vent termination 9 M x 3 ft/M = 18 ft. From Vent Manufacturer's instructions Add correction for flexible vent pipe,if any 1.8 x 20 ft = 36 ft. From Vent Manufacturer's instructions Total Equivalent Vent Length(TEVL) 163 ft. Add all of the above lines Maximum Equivalent Vent Length(MEVL) 127 ft. For 2"pipe from Table 2 Is TEVL less than MEVL? NO Therefore,60mm pipe may NOT be used; try 80 mm Maximum Equivalent Vent Length(MEVL) 250 ft. For 3"pipe from Table 2 Is TEVL less than MEVL? YES Therefore,80 mm pipe may be used NOTES: 1. Use only the smallest diameter pipe possible for venting. Over-sizing may cause flame disturbance or excessive vent terminal icing or freeze-up. 2. NA-Not allowed. Pressure switch will not close,or flame disturbance may result. 3. Total equivalent vent lengths under 10'for 40,000 BTUH furnaces from 0 to 2000 ft.(0 to 610 M)above sea level require use of an outlet choke plate. Failure to use an outlet choke when required may result in flame disturbance or flame sense lockout. 4. Not all furnace families include 140,000 BTUH input models. 5. Vent sizing for Canadian installations over 4500 ft(1370 M)above sea level are subject to acceptance by local authorities having jurisdiction. 6. Size both the combustion air and vent pipe independently,then use the larger size for both pipes. 7. Assume the two 45'elbows equal one 90'elbow. Wide radius elbows are desirable and may be required in some cases. 8. Elbow and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count. 9. The minimum pipe length is 5 ft.(2 M)linear feet(meters)for all applications. 10. Use 3-in.(76 mm)diameter vent termination kit for installations requiring 4-in.(102 mm)diameter pipe. 11 RETURN AIR TEMPERATURE This furnace is designed for continuous return-air minimum temperature of WIT(15°C)db or intermittent operation down to 55°F(13°C) db such as when used with a night setback thermometer. Return-air temperature must not exceed 80°F(27°C)db. Failure to follow these return air limits may affect reliability of heat exchangers,motors and controls. °F - It MAX 80°F /27°C SUPPLY AIR FRONT 32°F/0°C MINIMUM INSTALLED of AMBIENT OR FREEZE PROTECTION REQUIRED RETURN = I AIR MIN60°F / 16°C A10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0(0 mm) Front(Combustion air openings in furnace and in structure) 1 in.(25 mm) Required for service** 24 in.(610 mm)* All Sides of Supply Plenum** 1 in.(25 mm) Sides 0(0 mm) Vent 0(0 mm) Top of Furnace 1 in. (25 mm) *Recommended **Consult your local building codes COMBUSTION-AIR PIPE FOR NON-DIRECT (1-PIPE) VENT APPLICATION FIELD-SUPPLIED 2-IN. (51 mm) DIA. FIELD-SUPPLIED MITERED RADIUS 2-IN. (51 mm) DIA. PVC 900 ELBOW PVC PIPE f 12" (300 mm) MINIMUM A12376 NOTE: See Installation Instructions for specific venting configurations. 12 DOWNFLOW SUBBASE LOCATING TAB r1 1/4-IN.TYP PLENUM OPENING 3m 4m ® LOCATING \ TAB�® FACTORY-SUPPLIED C FIELD-INSTALLED INSULATION A97427 A88207 Assembled Disassembled DIMENSIONS(IN./MM) FURNACE FURNACE IN DOWNFLOW PLENUM OPENING* FLOOR OPENING HOLE NO.FOR WIDTH CASING WIDTH APPLICATION A B C D ADJUSTMENT 14-3/16(360) Furnace with or without Cased Coil 11-3/16 19(483) 13-7/16 20-5/8 4 Assembly or Coil Box (322) (341) (600) 17-1/2(445) Furnace with or without Cased Coil 15-1/8 19(483) 16-3/4 20-5/8 3 Assembly or Coil Box (384) (426) (600) 21 (533) Furnace with or without Cased Coil 18-5/8 19(483) 20-1/4 20-5/8 2 Assembly or Coil Box (396) (514) (600) 24-1/2(622) Furnace with or without Cased Coil 22-1/8 19(483) 23-3/4 20-5/8 1 Assembly or Coil Box (562) (603) (600) *The plenum should be constructed 1/4-in.(6 mm)smaller in width and depth than the plenum dimensions shown above. D � Concentric Vent Kit Downflow Subbase A93086 A88202 A concentric vent kit allows vent and combustion-air pipes to One base fits all furnace sizes. The base is designed to be installed terminate through a single exit in a roof or side wall. One pipe between the furnace and a combustible floor when no coil box is runs inside the other allowing venting through the inner pipe and used or when a coil box other than a Bryant cased coil is used. It is combustion air to be drawn in through the outer pipe. CSA design certified for use with Bryant branded furnaces when installed in downflow applications. 13 OPTIONAL MEDIA FILTER CABINET 25-5/8" (651 mm) 23 5/8" 24-1/4" (616mm) (600mm) Opening with Flanges Bent 23-1/8" 23-3/8" _ (588mm) (594mm) Opening U A 0 m ' Furnace Side ' Duct Side ' 23-3/4" (603mm) Centerline Screw Slots ~46m4m) Media Filter A B Cabinet 16" 406mm 17" (432mm) 16" 406mm 20" 508mm 21" (533mm) 20" 508mm 24" 610mm 25" 635mm 24" 610mm NOTE: Media cabinet is matched to the bottom opening on furnace. May also be used for side return. A12428 TYPICAL WIRING SCHEMATIC ---- FIELD 24-V WIRING ---- FIELD 115-,208/230-,460-V WIRING FACTORY 24-V WIRING FACTORY 115-V WIRING NOTE 2 THERMOSTAT FIVE WIRE w c Q Q Q TERMINALS FIELD-SUPPLIED THREE-WIRE i rI DISCONNECT HEATING-ONLY __ BLOWER DOOR SWITCH -- • 460-V 0 OR I I •--I •--- 60-V •--- THREE BLK B� U ' - - --- ------ PHASE C - WHT ----- -H ---�-- 0 I I I __ __�_____ N -- •---1 208/230-V =GND GND R L G --- -------j r- __ •___\ SINGLE I PHASE 115-V FIELD- AUXILIARY 0 ♦ _ ___ SUPPLIED J-BOX L coM -------------- i rim GND DISCONNECT ____NOTE 1 = ;_I UNNDENSING IT 24-V TWO TERMINAL WIRE BLOCK FURNACE NOTES: 1. Connect Y-terminal in furnace as shown for proper blower operation. 2. Some thermostats require a"C"terminal connection as shown. 3. If any of the original wire,as supplied,must be replaced, use same type or equivalent wire. A11387 14 DIMENSIONAL DRAWING T / ! � l�f,� � ƒƒ2{ § eEo% ( 2 e xoEa �a � < { \ \ )/ \\\/\ �\T® e\ � 1E � 5 $e>f § o ® � � ƒ\\\/G0 \ -g: E \� x x ro , o $ � � x�� ofy -V) § / (Vc:(N 0 E - ) /\\\/\� \k �§ ° / � E � G 8 -Or—0 r` tojo - o �g �= • _ ` ;-y±1 � \ && EEEI2a$e ; .. § E_>� ` � �= up � �\ 2 � S �22= � J� «\r\c4> E� �� 272:i-'E ®.. ;�® 2 -u btbtm22o [ boo';FE.0 2 § , rr4E - E/=� uu o� / q-- k , ^ , §<7 \ \\ §�S \§R $ ) 8 , z ¥ I / Au?; : ( \ \ / FJ ` . d + �§ a lz , { (! (! ; Li \) ] «226 7 _e a . c o SHIP WE FURNACE SIZE CABINET WIDTH OUTLET WIDTH BOTTOM INL ET WIDTH AIR INTAKE LB(KG) < ,wyn�> ,aw mm ,awns> agnG m�Am _< ,+a A@ _m m!Am _m ,c we) 1e7c) me) eAc) ,anc q _m ,cn Am 60080 ac> ,wmc) ,w we) ,s we> ,mn Am mm ,mn A% mz we) 7(581) ac) ,s G m» ,+n A@ 15 GUIDE SPECIFICATIONS General System Description Furnish a 4-way multipoise gas-fired Primary Heat Exchangers condensing furnace for use with natural gas or propane (factory- Primary heat exchangers shall be 3-Pass corrosion-resistant authorized conversion kit required for propane); furnish external aluminized steel of fold-and-crimp sectional design and applied media cabinet for use with accessory media filter or standard filter. operating under negative pressure. Quality Assurance Secondary Heat Exchangers Unit will be designed,tested and constructed to the current ANSI Z Secondary heat exchangers shall be of a stainless steel 21.47/CSA 2.3 design standard for gas-fired central furnaces. flow-through of fin-and-tube design and applied operating under Unit will be third party certified by CSA to the current ANSI Z negative pressure. 21.47/CSA 2.3 design standard for gas-fired central furnaces.Unit Controls will carry the CSA Blue Star® and Blue Flame® labels. Unit Controls shall include a micro-processor-based integrated efficiency testing will be performed per the current DOE test electronic control board with at least 16 service troubleshooting procedure as listed in the Federal Register. codes displayed via diagnostic flashing LED light on the control,a Unit will be certified for capacity and efficiency and listed in the self-test feature that checks all major functions of the furnace,and latest AHRI Consumer's Directory of Certified Efficiency Ratings. a replaceable automotive-type circuit protection fuse. Multiple Unit will carry the current Federal Trade Commission Energy operational settings available,including separate blower speeds for low heat,high heat,low cooling,high cooling and continuous fan. Guide efficiency label. Continuous fan speed may be adjusted from the thermostat. Delivery.Storage,and Handling Cooling airflow will be selectable between 325 to 400 CFM per Unit will be shipped as single package only and is stored and ton of air conditioning. Features will also include temporary handled per unit manufacturer's recommendations. reduced airflow in the cooling mode for improved Warranty (for inclusion by pecifying engineer) dehumidification when a T6-PRH is selected as the thermostat. U.S.and Canada only.Warranty certificate available upon request. Operating Characteristics Eguipment Heating capacity shall be Btuh input; Blower Wheel and ECM Blower Motor Btuh output capacity. Galvanized blower wheel shall be centrifugal type, statically and Fuel Gas Efficiency shall be AFUE. dynamically balanced. Blower motor of ECM type shall be Air delivery shall be cfm minimum at 0.50 in. permanently lubricated with sealed ball bearings, of hp, W.C.external static pressure. and have infinitely variable speed from 600-1200 RPM operating Dimensions shall be: depth in. (mm); width only when motor inputs are provided.Blower motor shall be direct in. (mm); height in. (mm) (casing only). drive and soft mounted to the blower housing to reduce vibration Height shall be in. (mm) with A/C coil and transmission. in.(mm)overall with plenum. Filters Electrical Requirements Furnace shall have reusable-type filters.Filter shall be in. Electrical supply shall be 115 volts,60 Hz,single-phase(nominal). (mm)X in.(mm). An accessory highly efficient Media Minimum wire size shall be AWG; maximum fuse size Filter is available as an option. Media Filter. of HACR-type designated circuit breaker shall be Casing amps. Casing shall be of.030 in.thickness minimum,pre-painted steel. SSgecial Features Draft Inducer Motor Refer to section of the product data identifying accessories and Draft inducer motor shall be two-speed PSC design. descriptions for specific features and available enhancements. ©2014 Bryant Heating&Cooling Systems a 7310 W.Morris St.a Indianapolis,IN 46231 Edition Date:10/14 Catalog No. PDS926TA-04 Manufacturer reserves the right to discontinue,or change at any time,specifications or designs without notice and without incurring obligations. Replaces:PDS926TA-03 16 Permit#: 2630 Permit Date: 06/25/19 Permit Type: RESIDENTIAL MECHANICAL Project Name: 17714 31st Dr NE Applicant Name: Washington Energy Services Applicant Address: 3909 196th St SW Applicant, City, State, Zip: Lynnwood, WA 98036 Contact: Phone: 206-378-6613 Email: Nhyett-schnell@washingtonenergy.com Scope of Work: Install gas furnace and gas water heater Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 07/23/2019 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00621300002600 17714 31 ST DR NE BLACKBURN 111 Single Family PROPERTIES LLC Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# WASHINGTON Karen Matheney 2063786648 3909 196th Street CONSTRUCTION COA 603 522 032 ENERGY SERVICES SW CONTRACTOR WASHINGTON Karen Matheney 2063786648 3909 196th Street CONSTRUCTION Labor&WASHIES851NS ENERGY SERVICES SW CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 07/25/2019 R00.WATER AM 07/25/2019 BUILDING Completed HEATER FINAL Fees Fee Description Notes Amount Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Water Heater(Tank) $25.00 Credit Card Service $3.00 Total $103.00 Attached Letters Date Letter Description 06/25/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 06/28/2019 CRAIG OLSON 75931935 iTransact CC $100.00 06/28/2019 75931935 CC Surcharge Raelynn Jones $3.00 Outstanding Balance $0.00 Notes Date Note Created By: 07/23/2019 Emailed permit for signature. Kristin Foster Uploaded Files Date File Name 09/24/2021 9760725-2630 IC 7.25.2019.pdf 07/23/2019 5358302-2630 Issued Permit.pdf 06/25/2019 5245376-2630 Specs.pdf 06/25/2019 5245283-2630 Application.pdf