Loading...
HomeMy WebLinkAbout19704 60TH AVE NE_BLD2490_2026 CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:19704 60th Ave NE Permit#:2490 Parcel#:00746300001100 Valuation:7591.00 OWNER APPLICANT CONTRACTOR Name: 19704 Properties LLC Name:Olympic Security&Communication Name:OLYMPIC SECURITY Address:7722 21st Ave NE Address:PO Box 3559 Address:PO BOX 3559 City,State Zip:Seattle,WA 981 IS City,State Zip:Arlington,WA 98223 City,State Zip:Arlington,WA 98223 Phone: Phone:360-652-1088 Phone:360-652-1088 LIC:OLYMPSC012QP EXP: II/17/2019 MECFIANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,'Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF=rUPANCY HAS BEEN GRANTED. IBC 110/IRCI 10. LE rAX N( I , Sa tax relating to construction and construction nuueri •in tl •City of Arlington must he reported on your sales tax return form and eot y 0 Signature Print Name Dat• Released By Date CONDITIONS 1.Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request. 2.Battery load test required, switch system to battery operation 24-hours prior to final inspection.Notification appliances to operate for 5 minutes on battery power. 3.Trouble condition to be verified for installation, notification and signaling circuits. 4.If fire sprinkler system lacks tampers or flow switches, such devices shall be installed and connected to fire alarm system. S.Installation completion form shall be submitted prior to project close-out. Call for inspections. THIS PERMIT AUTIIORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 4/8/2019 Fire Alarm Fee $100.00 4/8/2019 Fire Review Fee $145.87 4/8/2019 Processing/Technology Fee $25.00 Total Due: $270.87 Total Payment: S0:00 Balance Due: S27 CALL FOR INSPECTIONS - BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and wliether you prefer morning or afternoon I Permit Information Date 4/3/2019 Permit Number 2490 Project Name Meeco Manufacturing Fire Alarm Applicant Name Olympic Security&Communication Applicant Address PO Box 3559 City, State,Zip Arlington,WA 98223 Contact Vikki Ryason Phone 360-652-1088 Email vkki@olympicsecurity.com Permit Type Fire Alarm Site Address 19704 60th Ave NE Valuation 7591.00 Status Applied Permit Issued Permit Expires Square Feet 28000 Type of Construction/Occupancy Load Commercial Fire Alarm Number of Stories 0 Proposed Use Commercial Fire Alarm Assigned To Raelynn Jones Property Parcel Address Legal Owner Owner Phone Zoning 00746300001100 119704 60TH AVE NE 1 119704 Properties LLC 1399 Other Miscellaneous Manufacturing NEC Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# OLYMPIC SECURITY 360-652-1088 -uth s stemsoecialties.com CONTRACTOR -abor&Industries JOLYMPSC0120P Review Date Type Descri tion Target Date Completed Date Assigned To Status 4/3/2019 Fire Alarm 1/12/2019 IBuilding In Review 4/3/2019 =ire Alarm 4/12/2019 IFire lin Review Fees Fee Description Notes Amount Fire Alarm Fee 322.10.00.00 $100.00 Fire Review Fee 345.83.00.00 $145.87 Processing/Technology Fee 341.43.00.02 $25.00 Total $270.87 Uploaded Files Upload File Date I File Uploaded By -. I 4/3/2019 1:47:49 PM Meeco FA PLAN. Jones ?I nn1 x 4/3/2019 1:47:37 PM 2490 Calculations.pdf Jones,Rael nn X 4/3/2019 1:47:37 PM 2490 Application.pdf Jones,Raelynn I X •. I FIRE ALARM 7 PERMIT APPLICATION Department of Community & Economic Development City of Arlington • 18204 591h Ave NE •WA 98223 - Phone(360)403.3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO,INCLUDE SPECIFICATION SHEETS,WIRING DIAGRAMS,(POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) [] New Fire Alarm Fire Alarm Alteration/Addition Project Addresb. � ` �TV 1- ��• - Parcel ID#: Number of Zones/Panels: Building Area(Sq FI): D Valuation: G� , Owner: Phone Number: Address: City: State: Zip Code: Contact Person: Phone Number.LAacJ • R al D Cell Phone: Email: Address: City: State: Zip Code: O Contractor. `'� ` Phone Number: LP5 a- tc> Address: 1 City: --State: Zip Code: q�� �� Coontrctor's Llgense NumbeLs_�� C- i Expiration:-1` ContactPerson:_ �� _Email:�j At Electrical Contractor. Phone Number �u' CP�a- 7� Address•\ �� 5 City: Stale:U Zip Code-'I:��ate- J Contractor's Lic nse Number: Expiration 1\ I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws,rules and regulations of the State of Washington. - �-- f - I licants Signature Date zk, Cy Print Applicants Name ()� /n FOR STAFF USE ONLY f APR 0 2 2019 Permit# Accepted By Amount Received Receipt# Date Received WEB Form-130 Page 1 of 1 6116LP :t Labor - Safety&Health 6 Claims&Insurance Q Workplace Rights 0 Trades&Licensing 6 Washington State Department of " Labor & Industries OLYMPIC SEC &COMM SYS INC Owner or tradesperson PO BOX 3559 Principals ARLINGTON,WA 98223 360-652-1088 BROWN,TOM D,PRESIDENT SNOHOMISH County ■ BROWN,SANDRA D,VICE PRESIDENT BROWN,TOM D,AGENT Doing business as OLYMPIC SEC&COMM SYS INC WA UBI No. Business type 601 981 540 Corporation Governing persons SANDRA D BROWN TOM D JR BROWN; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Electrical Contractor Active. Meets current requirements. License specialties LIMITED ENERGY License no. OLYMPSC012QP Effective—expiration 11/17/1999-11/17/2019 Designated administrator Active. BROWN,TOM D Meets current requirements. License type License no. Master Electrician BROWNTD936BE Bond United States Fire Insurance Co $4,000.00 Bond account no. 615981521 Received by L&I Effective date 11/07/2012 11/17/2012 Expiration date Until Canceled OLD REPUBLIC SURETY CO $4,000.00 Bond account no. YLI238881 Effective date Help us improve l � r`Y. 11/17/1999 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations Infraction no. ECOXE01044 Satisfied Issue date RCW/WAC 02/22/2016 19.28.161 RCW Violation city Violation amount ARLINGTON $250.00 Type of violation ELECTRICAL CITATION Description Failing to provide proper supervision to an electrical trainee as required by chapter 19.28 RCW. Infraction no. ECOXE01043 Satisfied Issue date RCW/WAC 02/22/2016 19.28.271 RCW Violation city Violation amount ARLINGTON $250.00 Type of violation ELECTRICAL CITATION Description Employing an individual for the purposes of chapter 19.28 RCW who does not possess a valid certificate of competency or training certificate to do electrical work. Infraction no. EBANX00296 Satisfied Issue date RCW/WAC 04/29/2013 19.28.101 RCW Violation city Violation amount ARLINGTON $100.00 Type of violation ELECTRICAL CITATION Description Class B eligible work-Failing to obtain an electrical/telecommunications work permit,or post a provisional electrical work permit,or valid Class B label prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 570,943-01 Doing business as OLYMPIC SECURITY&COMMUNICATI Estimated workers reported Quarter 4 of Year 2018"4 to 6 Workers" L&I account contact T3/NATHAN KOZAK(360)902-6243-Email:KOZN235@lni.wa.gov Helpus Improve i Public Works Strikes and Deli cents Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. - - - •ktess Help us improve City of Arlington �1 G Fire Department April 6, 2019 Permit Number: BLD 2490 Project Address: 19704 60th Avenue NE, Arlington Project Description: Fire Alarm for Meeco Contractor: Vikki Ryason Olympic Security and Communication PO Box 3559 Arlington, WA 98223 Re: Fire Alarm Shop Drawing Review Comments and Approval The Arlington Fire Department has completed a review of the Fire Alarm shop drawing submittal and approves the issuance of the permit with the following conditions: 1. Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request. 2. Battery load test required, switch system to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3. Trouble condition to be verified for installation, notification and signaling circuits. 4. If fire sprinkler system lacks tampers or flow switches, such devices shall be installed and connected to fire alarm system. 5. Installation completion form shall be submitted prior to project close-out. Items noted above are conditions on the issued permit and shall be verified as part of the final inspection of the system at project completion. Final approval will not be provided until all conditions are verified. If there are any questions please do not hesitate to call. Sincerely, '& Mike Makela Assistant Fire Chief Arlington Fire Department OFFICE COPY 6231 :. , , , �� �� i i Global Project Values:InSILENT — - — — Project Name:I Meeco Standby Hours:KNIGHT 24 Project ID:I Alarm Mins:�5 Prepared By:IT Brown Derating Factor: 1.2 5495 Power ExpanderDate: 3/26/2019 j Voltage Drop Waming Threshold%: 20 Panel ID: 15495 Model: Silent Knight 5495 Power Expander Max Circuit Current: 3 Amps Location: INorthniser Volts: 24 VDC Max Panel Current: 6 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ o Ckt.# Circuit Name StandbyAlarm &Type 1000 Ft. One-Way Ohms EOL �oDrop 1 NE Offices 0.000 0.654 #14 Solid 2.52 75 0.38 20.15 1.21% 2 Country Save North Side 0.000 0.933 #14 Solid 2.52 225 1.13 19.34 5.19% 3 Meeco 0.000 1.204 #14 Solid 2.52 350 1.76 18.28 10.41% 4 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% Aux 5495(3)Aux Power Out 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% Aux Power `1 #of NAC's Used 0.000 0.000 5495 5495 Power Expander 0.075 0.175 2.791 Am s Total Output Power Required Total Standby Current(Amps) 0.075 2.966 Total Alarm Current(Amps) Standby Time In Hours 60 0.083 Alarm Time In Minutes/60 5 Mins Total Standby AH Required 4.500 0.247 Total Alarm AH Required Total Combined AH Required 4.75 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery Am Hours Required 5.70 *1. A value must be entered if you set up NAC circuits for Aux.Power. Received APR 0 2 2019 'bLD 2y90 i �, •� i FIRE SYSTEM •- Firepower 5495 Distributed Power Module Supervision Current: Input Firepower 5495 supervises a Standby 75 mA voltage range: 9 - 32 VDC variety of functions including: Alarm 175 mA Battery charging • Low AC power. Auxiliary capacity: 33.0 AH • Low battery condition. power circuit: 1 Ambient Temp.: 32' to 120' F • Earth ground fault. Notification 0° to 49' C • Auxiliary output power limit circuits: 4 Mechanical condition. Output Dimensions: 12.25" W x 16" H x • EOL supervision trouble or configuration: 2 Class A(Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output. (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B Firepower 5495 creates a trouble ) Indicator Lights Amps per AC power on : Green condition on the host control signal circuits to which it is connected. output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow Firepower 5495 still maintains the Notification Ground fault: Yellow ability to be activated by the host circuit output: 20 4 to 27.3 VDC control. In addition, the 5495 @ 3.0 amps each, Aux Trouble: Yellow provides a Form C trouble relay 4.7 kf2 EOL Output output as an alternative to using resistor required troubles (1-4): Yellow the notification circuit trouble. on each Class B Approvals: Electrical Specification circuit UL: 864 & 1481 AC Input: 120 VAC at 2 amps No. of inputs 2 NFPA: 72 Input CSFM Output: 24 VDC at 6 amps configuration. 2 Class B or 2 Class A Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal 1 input Distributed Signal2 Signal Circuit Output Signal 2 Power input Module 5495 Signal 3 (Optional) Signal 4 120 VAC Aux.Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) SILENT IQVIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM#350395, Rev.04/02 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Copyright©2002 Silent Knight FIRE SYSTEM ACCESSORY Firepower 5495 Distributed Power Module In an emergency, you need maximum power. A3 The Firepower 5495 Distributed Power Module by Silent Knight is the most- powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex@, Wheelock and Faraday—what you need to drive power-hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And,ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need Firepower 5495. Call Silent Knight today for more information at 1-800-446-6444. Firepower 5495 Independent trouble relay resistors provided. Since the 5495 Distributed Power Module AC loss delay option shuts off power draws very little power from the control, The firepower 5495 is a 6 amp to non-essential high-current it is possible to connect one Firepower notification power expander that accessories like magnetic door 5495 to each notification circuit on the provides its own AC power connection, holders control panel and still provide full battery charging circuit, and backup Built-in synchronization for supervision of the notification circuits all battery for use with fire and security appliances from System the way back to the control panel. controls such as the Silent Knight Sensor®,GenteO, Wheelock and Model 5208 Fire Control Faraday /Communicator. The 5495 is the cost- effective solution for powering Stand alone operation. notification appliances required by the Lightweight design adds to ease of Americans with Disabilities Act(ADA). installation and reduces shipping The 5495 has built-in ANSI cadence costs pattern,which can upgrade older Operates with most polarized, UL control panels that lack cadence Listed notification devices capability. UL 864& 1481 listed Features CSFM approved • UL Listed for 6 amps of notification power ANSI Cadence pattern output • Power supply's advanced switch capability built-in mode design reduces damaging Connection to Local Fire Control heat and manages power up to 50% Firepower 5495 may be connected to a more efficiently than other systems local fire control which utilizes Class A • Dip switches allow for easy or Class B type notification circuits reconfiguration operating between 9 and 32 VDC. The • 24 VDC filtered output voltage control panel's notification circuit is • Four power-limited notification connected to one of the inputs on the outputs; 2 Class A or 4 Class B, or 1 5495.The control panel's notification Firepower 5495 Class A and 2 Class B circuit end-of-line resistor is also Distributed Power Module • Additional continuous auxiliary connected across two terminals on the output Firepower 5495, which provides supervision between the 5495 and the • 3 amps per output circuit fire control panel. Polarized audible r SILENT • 2 inputs; 2 Class B or 2 Class A and/or visual notification devices are ( KNIGHT • Ground fault detector/indicator then connected to the 5495 signal circuits using the 4.71<0 end-of-line m 1 L-Series Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/e-inch back box,4 x 4 x 1 Y2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/e-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuif'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physicall/Electdcall Specifications Standard Operating Temperature 320F to 120OF(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR'.2 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7-W x 1,91-D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7-W x 1.25-D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133mm L x 88mm W x 32mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. SYSTEM �.� SENSOR" F F Indoor Selectable. Output Horns, E •'� E Strobes, and r�vr �� v�■ vlNc� �vlr Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Plug-in design with minimal intrusion into the back box plastic housings,standard and compact devices,and plain, FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela The L-Series line of wall-mount horns, strobes,and horn strobes • Field-selectable candela settings on wall units: include a variety of features that increase their application versatility 15,30,75,95, 110, 135,and 185 while simplifying installation.All devices feature plug-in designs • Horn rated at 88+dBA at 16 volts with minimal intrusion into the back box,making installations fast • Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming ground faults. • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage, the L-Series utilizes a universal mounting plate for all • Electrically Compatible with legacy SpectrAlert and SpectAlert models with an onboard shorting spring,so installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings Sisxauxs (9 LISTED AP°RO"Eo S5512 FM approved except 7125-1653:0504 S4011 Ior ALERT models 7135-1653:0503 3057383,3057072 11 SYSTEM SENSOR" Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications =- r, System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring, installers can test wiring Advance devices continuity before the device is installed. • Compatible with MD1_3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings &U` FM � LISTED 55512 FM approved except 7125-16530504 54011 for ALEFf models 7135-16530503 �)Ey r r'. /Q 3057363 R � e 1 V l.o APR 0 2 2019 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1'/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at i Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenur i lids!i iube grid associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. I he horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Serles strobes at I Hz and Iwrns al lernpural llrree.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit..The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 320F to 120OF(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR' Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(94V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6-8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6 9"diameter x 3.4"high(17.9 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86800 1 �[ KNRAI I Circuit Configuration r Project Information Project Name: Meeco Project ID: 0 Prepared By: T Brown Date: 3/26/2019 Ckt.Number: 1 Panel ID:5495 Ckt.Name: NE Offices Max Circuit Current: 3 Amps city Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor P21-Wall Horn/Strobe 110 cd) 0.000 0.043 0.000 0.043 2 System Sensor P21-Wall Horn/Strobe(30 cd) 0.000 0.121 0.000 0.242 3 System Sensor P21-Wall Horn/Strobe 15 cd 0.000 0.044 0.000 0.132 1 System Sensor P21-Wall Horn/Strobe 75 cd) 0.000 0.111 0.000 0.111 0 0.000 0.126 Totals 0.000 0.654 Ckt.Number:2 Panel ID:5495 Ckt.Name:Country Save North Side Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 System Sensor SL Wall Strobe 15cd 0.000 0.043 0.000 0.086 1 System Sensor P2L Wall Horn/Strobe 30 cd 0.000 0.065 0.000 0.065 1 System Sensor P21-Wall Horn/Strobe 75 cd 0.000 0.111 0.000 0.111 3 System Sensor PC21-Ceiling Horn/Strobe(115 c 0.000 0.202 0.000 0.606 0.000 0.065 Totalsl 0.000 1 0.933 Ckt:Number: 3 Panel ID: 5495 Ckt.Name: Meeco Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor PC21-Ceiling Horn/Strobe 115 0.000 0.202 0.000 0.808 2 System Sensor P21-Wall Horn/Strobe 95 cd 0.000 0.133 0.000 0.266 2 System Sensor P21-Wall Horn/Strobe 30 cd 0.000 0.065 0.000 0.130 0 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsj 0.000 1 1.204 Ckt.Number. 4 Panel ID: 5495 Ckt.Name: 0 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 0 Unused 0.000 0.000 1 0.000 0.000 0 Unused 0.000 0.000 0.000 0.000 0 Unused 0.000 0.000 0.000 0.000 0 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1 0.000 Ckt.Number:Aux Panel ID:5495 Ckt.Name: 5495(3)Aux Power Out Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alann Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1 0.000 - - - - - - � j,.._ ��� 1 �� I r, 1 i Approved 4-8-19 By: Mike Makela S 1. Permit and set of approved plans to remain on site during installation. ,' �`� I �I �ri Installers shall present NICET II certification upon request. �,-- 75 2. Battery load test required, switch system to battery operation 24-hours prior �� NAC R 5 S S -- to final inspection. Notification appliances to operate for 5 minutes on battery r ILU power. i 3. Trouble condition to be verified for installation, notification and signaling circuits. i ---' ► S S 1 '� �/ 4. If fire sprinkler system lacks tampers or flow switches, such devices shall be I 1 — I installed and connected to fire alarm system. 5. Installation completion form shall be submitted prior to project close-out. ———————— I 115 �115 ,-----' 115 i o `�-- I ` I 1 1 I / / i i i i 95 �, 115 1 115 30 1- I I � I I 1 I I I I I I I I I 1 I I 1 I 1 ' IOFFICE PY � 1 I 30 aHfl j 95 I 115 i 115 00 is o zs o so 0 • Meeco fio th Fire Alarm System 512E DATE DRAWN BY REV APR 0 3 2019 3/25/2019 T Brown NICET ID 144003 i 800-540-SAFE SCALE 1:1s0 Floor Plan SHEET 1 OF 2 OS Smoke Detector SK-SMOKE 1 O Valve Tamper by OTHERS 1 O Flow Switch by OTHERS 1 R-6 Relay Output SK-RELAY-6 0 Dual Input SK- 0 -2 MONITOR-2 IR Relay/Trigger SK-CONTROL 0 Dual Relay/Input SK- RELAYMON-2 0 NAC#1 H; H H H $ $ S n Strobe SRL 6 110 30 30 75 15 15 15 15 Horn-Strobe (C) PC2RL 7 NAC#2 - - H H H H H S S 30 11 11 11 75 30 15 15 HK Strobe (C) SCRL 0 30 NAC#3 H❑� Horn-Strobe P2RL 9 95 5"� — 1 5 11 115 30 30 - 30 FAP Fire Alarm Panel SK-5808 0 NAC Signal Power Panel SK-5495 2 NAC ----- ------------------ i i i FAP i (F) i i oil Meeco 19704 60th Ave. NE, Arlington Existing control system, DSC PC4020CF. Existing sprinkler devices to remain. Fire Alarm System Upgrade, CAI Existing communications to remain. 512E DATE DRAWN BY REV Adding notification devices ONLY. 28-JAN-2019 T Brown NICET ID 144003 1 800-540-SAFE SCALE 3/32"=1'-0" Riser SHEET 2 OF 2 FIRE ALARM PERMIT APPLICATION Department of Community &Economic Development City of Arlington• 18204 591h Ave NE•WA 98223• Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2)SETS OF COMPLETE AND SCALED PLANS FOR EACH FIRE ALARM PERMIT APPLICATION.INCLUDE ELECTRICAL PLANS WHERE APPLICABLE.ALSO,INCLUDE SPECIFICATION SHEETS,WIRING DIAGRAMS,(POINT TO POINT WIRING),AND ALL OTHER INFORMATION ON EQUIPMENT PROPOSED TO BE INSTALLED PRIOR TO INSTALLATION. Type of permit: (check one) M New Fire Alarm Fire Alarm Alteration/Addition Prolecl Address. l t� ✓ � �- Parcel ID#: Number of Zones/Panels: Building Area(Sq FI): Valuation: Owner: Phone Number: Address: City: State: Zip Code: Contact Person: s- �> G-s cam- ��s Plane Number:LAaS a c)a- Cell Phone: Email: Address: City: Slate: Zip Code: Contractor. ` C` Phone Numm er: Address: C City: '� t �� � State: Zip Code: Contr ctor's Ligense Numbe . �C l a-�, ` _Expiration:-,` t� ContactPerson: .......ts� Electrical Contractor. C� Phone Numb Co Co S a Address City: Slater n��� Zip Code'— Contractor's Llc nse Number: �� �x O Expiration„ -� I hereby certify the above information is correct and that the construction on, and the occupancy and the use of the above described property will be accordance with the laws,rules and regulations of the State of Washington. p licants Signature pate ot O Print Applicants Name 'K L FOR STAFF USEONLY 2L4ot0 .APR 0 2 2019 Permit# Accepled By Amount Received Receipt# Date Recelved WEB Form-130 Page 1 of 1 6/16LP Global Project Values: SILENT Project Name:I Meeco Standby Hours:KNIGHT 24 Project ID: Alarm Mins: Prepared By:IT Brown , Derating Factor: 5495 Power Ex•- •- Date: 3/26/2019 Voltage Drop Waming Threshold% Panel ID: 15495 Model: Silent Knight 5495 Power Expander Max Circuit Current: 3 Amps Location: INorth Riser I Volts: 24 VDC Max Panel Current: 6 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm &Type 1000 Ft. One-Way Ohms EOL 1 NE Offices 0.000 0.654 #14 Solid 2.52 75 0.38 20.15 1.21% 2 Country Save North Side 0.000 0.933 #14 Solid 2.52 225 1.13 19.34 5.19% 3 Meeco 0.000 1.204 #14 Solid 2.52 350 1.76 18.28 10.41% 4 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% Aux 5495(3)Aux Power Out 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% Aux Power *1 #of NAC's Used 0.000 0.000 5495 5495 Power Expander 0.075 0.175 2.791 Am s Total Output Power Required Total Standby Current(Amps) 0.075 2.966 Total Alarm Current(Amps) Standby Time In Hours 60 0.083 Alarm Time In Minutes/60 5 Mins Total Standby AH Required 4.500 0.247 Total Alarm AH Required Total Combined AH Required 4.75 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply B The Deratin Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery Am Hours Required 5.70 *1. A value must be entered if you set up NAC circuits for Aux.Power. KNJ(411 Circuit Configuration - Project Information Project Name: Meeco Project ID: 0 Prepared By: T Brown Date: 3/2 612 0 1 9 Ckt.Number: 1 Panel ID:5495 Ckt.Name: NE Offices Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor P21-Wall Horn/Strobe 110 cd) 0.000 0.043 0.000 0.043 2 System Sensor P2L Wall Horn/Strobe 30 cd 0.000 0.121 0.000 0.242 3 System Sensor P21-Wall Horn/Strobe 15 cd 0.000 0.044 0.000 0.132 1 System Sensor P21-Wall Horn/Strobe 75 cd) 0.000 0.111 0.000 0.111 0 0.000 0.126 Totalsl 0.000 1 0.654 Ckt.Number:2 Panel ID:5495 Ckt.Name: Country Save North Side Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 System Sensor SL Wall Strobe 15cd 0.000 1 0.043 0.000 0.086 1 System Sensor P2L Wall Horn/Strobe 30 cd 0.000 0.065 0.000 0.065 1 System Sensor P21-Wall Horn/Strobe 75 cd 0.000 0.111 0.000 0.111 3 System Sensor PC2L Ceiling Horn/Strobe 115 0.000 0.202 0.000 0.606 0.000 0.065 Totalsi 0.000 1 0.933 Ckt.Number:3 Panel ID: 5495 Ckt.Name: Meeco Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 System Sensor PC21-Ceiling Horn/Strobe 115 0.000 0.202 0.000 1 0.808 2 System Sensor P21-Wall Horn/Strobe 95 cd) 0.000 0.133 0.000 0.266 2 System Sensor P2L Wall Horn/Strobe 30 cd 0.000 0.065 0.000 0.130 0 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsi 0.000 1.204 Ckt.Number:4 Panel ID:5495 Ckt.Name: 0 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 0 Unused 0.000 0.000 0.000 0.000 0 Unused 0.000 0.000 0.000 0.000 0 Unused 0.000 0.000 0.000 0.000 0 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1 0.000 Ckt.Number.Aux Panel ID:5495 Ckt.Name: 5495(3)Aux Power Out Max Circuit Current: 3 Amps City Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 10.000 0.000 0.000 Totals 0.000 0.000 SYSTEM �4 SENSOR- F +' F Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification _ products are rich with features guaranteed to cut t l � installation times and maximize profits with lower i current draw and modern aesthetics. - J Features • Updated Modern Aesthetics The System Sensor L•Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns, strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Plug-in design with minimal intrusion into the back box plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela The L-Series line of wall-mount horns,strobes,and horn strobes • Field-selectable candela settings on wall units: include a variety of features that increase their application versatility 15,30,75,95, 110. 135,and 185 while simplifying installation.All devices feature plug-in designs • Horn rated at 88+dBA at 16 volts with minimal intrusion into the back box,making installations fast • Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming ground faults. • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,the L-Series utilizes a universal mounting plate for all • Electrically Compatible with legacy SpectrAlert and SpectAlert models with an onboard shorting spring,so installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings Sicruwxs O O ,. F N AVPAOYEO ` LISTED 55512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-16530503 .�eceiv 3057383,3057072 APR 0 2 2019 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/e-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110. 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 320F to 120OF(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR'.2 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.25-D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133mm L x 88mm W x 32mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. *-"') SYSTEM � SENSOR Indoor Selectable- ' Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower _ current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30, 75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring, installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings $16NAUM8 LISTED APPHOVEU 55512 FM approved excepl 7125-16530504 S4011 for ALEW models 7135-16530503 3057363 °" � uR 0 2 ?_n19 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1'/cinch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. i Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. -Physical/Electrical Specifications Standard Operating Temperature 320F to 1200F(0°C to 490C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR' Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86800 FIRE SYSTEM •- Firepower 5495 Distributed Power Module i In an emergency, you need maximum power. ,Q D L7 The Firepower 5495 Distributed Power Module by Silent Knight is the most- powerful and cost-effective power supply available today. It delivers 6 amps of I otification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, Wheelock and Faraday—what you need to drive power-hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And,ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need Firepower 5495. Call Silent Knight today for more information at 1-800-446-6444. Firepower 5495 Independent trouble relay resistors provided. Since the 5495 Distributed Power Module AC loss delay option shuts off power draws very little power from the control, The firepower 5495 is a 6 amp to non-essential high-current it is possible to connect one Firepower notification power expander that accessories like magnetic door 5495 to each notification circuit on the provides its own AC power connection, holders control panel and still provide full battery charging circuit, and backup Built-in synchronization for supervision of the notification circuits all battery for use with fire and security appliances from System the way back to the control panel. controls such as the Silent Knight Sensor@,Gentex®, Wheelock and Model 5208 Fire Control Faraday /Communicator. The 5495 is the cost- effective solution for powering Stand alone operation. notification appliances required by the Lightweight design adds to ease of Americans with Disabilities Act(ADA). installation and reduces shipping The 5495 has built-in ANSI cadence costs pattern, which can upgrade older Operates with most polarized, UL control panels that lack cadence Listed notification devices capability. UL 864& 1481 listed Features CSFM approved • UL Listed for 6 amps of notification power ANSI Cadence pattern output • Power supply's advanced switch capability built-in mode design reduces damaging Connection to Local Fire Control heat and manages power up to 50% Firepower 5495 may be connected to a more efficiently than other systems local fire control which utilizes Class A • Dip switches allow for easy or Class B type notification circuits reconfiguration operating between 9 and 32 VDC. The • 24 VDC filtered output voltage control panel's notification circuit is • Four power-limited notification connected to one of the inputs on the outputs; 2 Class A or 4 Class B, or 1 5495. The control panel's notification Firepower 5495 Class A and 2 Class B circuit end-of-line resistor is also Distributed Power Module Additional continuous auxiliary connected across two terminals on the output Firepower 5495,which provides supervision between the 5495 and the • 3 amps per output circuit fire control panel. Polarized audible SILENT 2 inputs; 2 Class B or 2 Class A and/or visual notification devices are KNIGHT Ground fault detector/indicator then connected to the 5495 signal t?�:f?gayeo, circuits using the 4.7kQ end-of-line APR 0 2 2019 FIRE SYSTEM O. Firepower 5495 Distributed Power Module Supervision Current: Input Firepower 5495 supervises a Standby 75 mA voltage range: 9 - 32 VDC variety of functions including: Alarm 175 mA Battery charging • Low AC power. Auxiliary capacity: 33.0 AH • Low battery condition. power circuit: 1 Ambient Temp.: 32' to 120' F • Earth ground fault. Notification 0° to 49° C • Auxiliary output power limit circuits: 4 Mechanical condition. Output Dimensions: 12.25" W x 16" H x • EOL supervision trouble or configuration: 2 Class A(Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output. (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights Firepower 5495 creates a trouble condition on the host control signal Amps per AC power on : Green circuits to which it is connected. output circuit: 3 0 (6.0 amps total) Battery trouble: Yellow Firepower 5495 still maintains the Notification Ground fault: Yellow ability to be activated by the host circuit output: 20.4 to 27.3 VDC control In addition, the 5495 @ 3.0 amps each, Aux Trouble: Yellow provides a Form C trouble relay 4.7 kQ EOL Output output as an alternative to using resistor required troubles (1-4): Yellow the notification circuit trouble. on each Class B Approvals: Electrical Specification circuit UL: 864 & 1481 AC Input: 120 VAC at 2 amps No. of inputs 2 NFPA: 72 Input CSFM Output: 24 VDC at 6 amps configuration. 2 Class B or 2 Class A Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal 1 input Distributed Signal2 Signal Circuit Output Signal 2 Power Input Module 5495 Signal 3 (Optional) Signal 4 120 VAC Aux.Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM#350395, Rev 04/02 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Copyright©2002 Silent Knight Approved 4-8-19 By: Mike Makela i 1. Permit and set of approved plans to remain on site during installation. ��--�\ I S N ` Installers shall present NICET II certification upon request. k I 'H 2. Battery load test required, switch system to battery operation 24-hours prior I„ � NAC R�S ` S N � � 75 to final inspection. Notification appliances to operate for 5 minutes on battery � S o , / M / power. / \ o 1 / 3. Trouble condition to be verified for installation, notification and signaling �\\ o ; circuits. ---'- S S 4. If fire sprinkler system lacks tampers or flow switches, such devices shall be I — installed and connected to fire alarm system. �\ �\ I 5. Installation completion form shall be submitted prior to project close-out. I � � 115 115 -----' 115 I o � I I I 1 I I i i i i i i i i i � 95 115 1115 -- 30 1i I � I I I � I I � I I I I I I I I I I I I I I OP` OFFICE I — I I 30 95 I 115 1 115 00 150 250 500 Meeco 1970460 th Ave, NE. Arlinaton Fire Alarm System SIZE DATE DRAWN BY REV APR 0 3 2019 1 3/25/2019 T Brown NICET ID 144003 1 1 � 2'RD 800-540-SAFE SCALE 1:180 Floor Plan ISHEET 1 OF 2 (3) Smoke Detector SK-SMOKE 1 O Valve Tamper by OTHERS 1 O Flow Switch by OTHERS 1 R-6 Relay Output SK-RELAY-6 0 1 Dual Input SK- 0 -2 MONITOR-2 Relay/Trigger SK-CONTROL 0 Dual Relay/Input SK- RELAYMON-2 0 NAC 01 H H H H S S S ❑S Strobe SRL 6 110 30 30 75 15 15 15 15 JC Horn-Strobe (C) PC2RL 7 NAC#2 H H H H H S S 30 115 11 11 75 30 15 15 H❑� Strobe (C) SCRL 0 30 NAC#3-- - {-qQ.......( Hj�-.._.��._.._�......��......�H�--__�...._.(� H� Horn-Strobe P2RL 9 95 95 `-1155 115 11 '-11 30 30 30 Fire Alarm Panel SK-5808 0 ® Signal Power Panel SK-5495 2 NAC i ------ ----------------- FAP OT OS i O i ; • Meeco 19704 60th Ave. NE, Arlington Existing control system, DSC PC4020CF. Existing sprinkler devices to remain. Fire Alarm System Upgrade, CAI Existing communications to remain. 512E DATE DRAWN BY REV Adding notification devices ONLY. 28-JAN-2019 T Brown NICET ID 144003 1 800-540-SAFE SCALE 3/32"=V-0" Riser SHEET 2 OF 2 CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON,WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:19704 60th Ave NE Permit#:2490 Parcel#:00746300001100 Valuation:7591.00 OWNER APPLICANT CONTRACTOR Name:19704 Properties LLC Name:Olympic Security&Communication Name:OLYMPIC SECURITY Address:7722 21st Ave NE Address:PO Box 3559 Address:PO BOX 3559 City,State Zip:Seattle,WA 98115 City,State Zip:Arlington,WA 98223 City,State Zip:Arlington,WA 98223 Phone: Phone:360-652-1088 Phone:360-652-1088 LIC:OLYMPSC012QP EXP: II/17/2019 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date Released By Date CONDITIONS 1.Permit and set of approved plans to remain on site during installation. Installers shall present NICET II certification upon request. 2.13attery load test required, switch system to battery operation 24-hours prior to final inspection.Notification appliances to operate for 5 minutes on battery power. 3.Trouble condition to be verified for installation,notification and signaling circuits. 4.If fire sprinkler system lacks tampers or flow switches, such devices shall be installed and connected to fire alarm system. 5.Installation completion form shall be submitted prior to project close-out. Call for inspections. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 4/8/2019 Fire Alarm Fee $100.00 4/8/2019 Fire Review Fee $145.87 4/8/2019 Processing/Technology Fee $25.00 Total Due: $270.87 Total Payment: $0.00 Balance Due: $270.87 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon I I { i i II i CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:19704 60th Ave NE Permit#:2490 Parcel#:00746300001 I00 Valuation:7591,00 OWNER APPLICANT CONTRACTOR Name: 19704 Properties LLC Name:Olympic Security&Communication Name:OLYMPIC SECURITY Address:7722 21st Ave NE Address:PO Box 3559 Address:PO BOX 3559 City,State Zip:Seattle,WA 98115 City,State Zip:Arlington,WA 98223 City,State Zip:Arlington,WA 98223 Phone: Phone:360-652-1088 Phone:360-652-1088 LIC:OLYMPSC012QP EXP: 11/17/2019 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Fire Alarm CODE YEAR: 2015 STORIES: CONST TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE UP UPANCY HAS BEEN GRANTED. IBCI IO/IRCl10. LCS TAX N( 'I - .Sa -s tax relating to construction and construction tnateria:in tl City of Arlington must be reported on your sales tax return farm and cat c "y o Signatuie Print Name Dale Released By Date CONDITIONS 1.Permit and set of approved plans to remain on site during installation. Installers shall present NICET 1I certification upon request. 2.13attery load test required, switch system to battery operation 24-hours prior to final inspection. Notification appliances to operate for 5 minutes on battery power. 3.Trouble condition to be verified for installation, notification and signaling circuits. 4.If fire sprinkler system lacks tampers or flow switches, such devices shall be installed and connected to fire alarm system. 5.Installation completion form shall be submitted prior to project close-out. Call for inspections. THIS PERMIT AUTFIORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 4/8/2019 Fire Alarm Fee $100.00 4l8/2019 Fire Review Fee $145.87 4/812019 ProcessingfTechnology Fee $25.00 Total Due: $270,87 Total Payment: $0.00 Balance Due: S27 CALL FOR INSPECTIONS �� BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit#: 2490 Permit Date: 04/03/19 Permit Type: FIRE ALARM Project Name: Meeco Manufacturing Applicant Name: Olympic Security& Communication Applicant Address: PO Box 3559 Applicant, City, State, Zip: Arlington,WA 98223 Contact: Vikki Ryason Phone: 360-652-1088 Email: vkki@olympicsecurity.com Scope of Work: Commercial Fire Alarm Valuation: 7591.00 Square Feet: 28000 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 04/09/2019 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 399 Other 00746300001100 19704 60TH AVE NE LLC 4 Properties Miscellaneous Manufacturing NEC Contractors Contractor Primary Contact Phone Address Contractor Type License License# OLYMPIC SECURITY 360-652-1088 PO BOX 3559 CONSTRUCTION Labor& OLYMPSC012QP CONTRACTOR Industries Plan Reviews Date Review Type Description Assigned To Review Status 04/03/2019 FIRE ALARM BUILDING 04/03/2019 FIRE ALARM FIRE Fees Fee Description Notes Amount Fire Alarm Plan Review Fee $100.00 Fire System Plan Review Table 4-1 $145.87 Processing/Technology $25.00 Credit Card Service $8.13 Photocopies 8 @.10 ea. $0.80 Total $279.80 Attached Letters Date Letter Description 04/08/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 04/09/2019 Olympic Security Ryason 74805977 iTransactCC $270.87 04/09/2019 CC Surcharge CC Surcharge Raelynn Jones $8.13 #74809111 07/12/2019 Olympic Security Cash $0.80 Outstanding Balance $0.00 Notes Date Note Created By: 07/12/2019 Requested second copy of Job Copy due to the loss of the original set. Raelynn Jones Uploaded Files Date File Name 04/09/2019 4739209-2490 Signed permit.pdf 04/08/2019 4735594-Meeco Fire Alarm Plan Review.docx 04/03/2019 4718947-Meeco FA PLAN.pdf 04/03/2019 4718944-2490 Application.pdf 04/03/2019 4718945-2490 Calculations.pdf � � I S � \I 7 ` 5 �� / u —I S S u / d cY1 / /^\ O /H � I LK 115 \115 ,_---- 115 i F" � I ' I I I 1 I i i i i i i i i �\ 95 \ 115 1115 30 / I I / I I I I I I I I 1 I I 1 I 1 I I I 30 /1 III 95 I 115 115 00 is o zs o so 0 eeco 970460 th Ave, NE. Arlonecyton Fire Alarm System SIZE DATE DRAWN BY REV 3/25/2019 T Brown NICET ID 144003 1 800-540-SAFE SCALE 1:180 Floor Plan I SHEET 1 of 2 Smoke Detector SK-SMOKE 1 O Valve Tamper by OTHERS 1 O Flow Switch by OTHERS 1 R-6 Relay Output SK-RELAY-6 0 Dual Input SK- 0 -2 MONITOR-2 ® Relay/Trigger SK-CONTROL 0 Dual Relay/Input SK- RELAYMON-2 0 NAC#1 H H H H S S S 0 Strobe SRL 6 110 30 30 75 15 15 15 15 LN Horn-Strobe (C) PC2RL 7 NAC#2 H L u N uJ uJ uJ u u 30 115 115 115 75 30 15 15 Strobe (C) SCRL 0 30 � H Horn-Strobe P2RL g NAC#3 ------.EK.----- K 95 95 115 115 115 115 30 30 30 FAP Fire Alarm Panel SK-5808 0 NAC Signal Power Panel SK-5495 2 NAC r----- ------------------ � FAP O ' OLYMPIC SECURITY Meeco ------------------------ COMMUNICATIONS 1970460 Ave. NE, Arlington Existing control system, DSC PC4020CF. Existing sprinkler devices to remain. Fire Alarm System Upgrade, CAI Existing communications to remain. - _ SIZE DATE DRAWN BY REV Adding notification devices ONLY. - 28-JAN-2019 T Brown NICET ID 144003 1 800-540-SAFE SCALE 3/32"=V-0. Riser SHEET 2 OF 2