HomeMy WebLinkAbout19313 46TH AVE NE_BLD2486_2026 CoiTY OF ARLIAGTON
238 N. OLYMPIC AVE - ARLINGTON, WA. 98223
PHONE; (360) 403-3551
BUILDING PERMIT
Address:19313 46th Ave NE Permit#:2486
Parcel#:00928200009500 Valuation:0.00
OWNER APPLICANT CONTRACTOR
Name:HILL ERIC S&HEATHER MARZEC Name:Heat King Mechanical Name:Heat King Mechanical
Address: 19313 46TH AVE NE Address:6810 Silvana Terrace Rd Address: 11330 4th Ave West
City,State Zip:ARLINGTON,WA 98223 City,State Zip:Stanwood,WA 98292 City,State Zip:Everett,WA 98204
Phone: Phone:425-409-4661 Phone:425-409-4661
LIC: EXP:
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Naive:Heat King Mechanial Name:
Address: 1130 4th Ave W. Address:
City,State,Zip:Everett,WA 98204 City,State,Zip:
Phone:425-409-4661 Phone:
LIC#:BLWILC*075LP EXP: 09/17/2020 LIC#: EXP:
JOB DESCRIPTION
PERMIT TYPE: Residential Mechanical CODE YEAR: 2015
STORIES: CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,
NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110.
SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlingty n tsl be reported n your sales tax r fand coded City of Arlington#3101. p
Signature Print Name Date 1�6k ad By Dat l
CONDITIONS
3" Concrete pad with seismic bracing attached. Provide electrical disconnect.Lines shall be insulated; use of
adhesive tapes are prohibited. Adhere to approved appliance. Call for final inspection.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION
ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
4/2/2019 A/C Unit $25.00
4/2/2019 Furnace $25.00
4/2/2019 Mechanical Permit Base Fee $25.00
4/2/2019 Processing/Technology Fee $25.00
Total Due: $100.00
Total Payment: $0.00
Balance Due: $100.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
.r - �
I
_ _
°ly RESIDENTIAL MECHANICAL
PERM T APPLICATION
t �'1 Department of Community&Economic Development
City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND
OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION
AND INCLUDE ALL INFORMATION.
Project Address. / 1 --s / 3 q� 4— A( l�_
Project Description: �i �i4 �4,L 5�4 _ �,-Z T� �
Owner: A Y41LEZ
-
Address: Z9Jly � /C_ City: ,/� i✓Stater Zip Code:
Phone: &Z_ lit Email:
Applicant:
Address: City: State: Zip Code:
Phone: Email:
CONTRACTOR INFORMATION
Contractor Name:�� t,5dK1 461,
Address: 61+L1 p 61b"A Tvg&-�-laity: g�_ State: Z,) Zip Code: (�
License Number: �FLtJ l L� D X L Expiration:
Phone: S7 y- Email: _� l l d j ��__�,//f"G7
STAFF USE O
Permit#: Z��(p Accepted b Date:APR 01 W9
6/16LP Page 1 of 2
RESIDENTIAL MECHANICAL
PERMIT APPLICATION
IN Department of Community&Economic Development
City of Arlington • 18204 59th Ave NE •Arlington,WA 98223 • Phone(360)403-3551
SELECT AL�LI PROPOSED APPLIANCES
[ Furnace (80+) Model# /� Ivt�� 01� AFUE c
Heat Pump Model# AFUE HSPE
AC Unit Model# L4A Z- q L— h SEER
Freestanding Stove I Fire Place Insert ❑ Outdoor BBQ
Gas Piping ❑' Solid-Fuel Appliance ❑ Other
Gas Piping Information
Not Applicable: ❑
Pipe Material:
Pipe Size
Distance from Meter to Furthest Appliance:
Total BTU's of all Appliances:
• New gas piping requires a pressure test hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper Combustion air and venting required for all appliances
• A shut-off valve is required within 6 feet of all appliances
Applicant Signature: _e Date,/4,
Applicant Printed Name:
1 hereby certify that the above information is correct and that the construction, installation for the above mentioned
property will be in accordance with the applicable laws of the City of Arlington and the State of Washington.
6/16LP Page 2 of 2
All"01wo N8MXL
Product Specifications
80% ECM Single Stage Heating Furnace
EASIER TO SELL
• 80%AFUE
•Supports two-stage cooling units -
• Flame roll-out sensors standard
• Category I venting -
• Blocked vent switch
• Dehumidification feature in cooling i
• 24 VAC humidifier terminal
• Electronic air cleaner terminal
• N8MXL model California NOx approved
• Certified to leak 2 percent or less of nominal air conditioning y
CFM delivered when pressurized to 1-inch Water Gauge with all
present air inlets, air outlets, and condensate drain port(s)sealed
TOUGHER
• ECM blower motor
•Adjustable heating blower OFF delay
• Factory set blower ON delay
• RPJ aluminized steel heat exchanger
• High temperature limit control prevents overheating
• Direct ignition with Silicon Nitride ignitor Illustrations and photographs are only representative.
• One piece prepainted steel cabinet Some product models may vary.
QUIETER
• In-shot burners
• Insulated blower compartment WARNING
EASIER TO INSTALL AND SERVICE I his furnace is not designed for use in mobile homes,
•33 1/3"(847mm) high,for ease of installation trailers, or recreational vehicles.Such use could
• Innovative knobs for easy door removal and secure attachment result in property damage and/or death.
• Factory shipped for natural gas, with propane
gas conversion kits available
A"Imp
• Four position-upflow/downflow/horizontal (left/right)
installation
•Three position vent elbow capability I
LC
go to www.ahridirectory.org.
•Through the casing flue pipe for counterflow applications manufacturer''ss p Use of the A Certified Mark indicates participation in n the program.For
•Common venting with other Category I appliances verification of certification for individual products,
• Masonry chimney adapter available
• Self diagnostics ISO 9001 W10
•Slide out blower assembly oku-saw
WARRANTY*
• 20 year heat exchanger limited warranty Nrff%``�®
• 10 year parts limited warranty with timely registration
• 5 year parts limited warranty if not registered within 90 days of original installation
* For residential applications only. See warranty certificate for complete details and restrictions, including
warranty coverage for other applications.
Input Efficiency Cooling Capacity Dimensions H x W x D Shipping Wt.
Model Size (MBTUH) AFUE CFM range Inches(Millimeters) Lbs(Kg)
@.5 in.w.c.(125 Pa)
N8MXL 0451412 44,000 80°% 415—1080 33-1/3 x 14-3/16 x 29(847 x 360 x 737) 104(47)
N8MXL 0701712 66,000 80% 385—1005 33-1/3 x 17-1/2 x 29(847 x 445 x 737) 126(57)
N8MXL 0701716 66,000 80% 875—1435 33-1/3 x 17-1/2 x 29(847 x 445 x 737) 126(57)
N8MXL 0901714 88,000 80% 750—1210 33-1/3 x 17-1/2 x 29(847 x 445 x 737) 127(58)
N8MXL 0902116 88,000 80% 845—1445 33-1/3 x 21 x 29(847 x 533 x 737) 140(64)
N8MXL 1102120 110,000 80% 990—2040 33-1/3 x 21 x 29(847 x 533 x 737) 152(69)
N8MXL 1352420 132,000 80% 1025—1810 33-1/3 x 24-1/2 x 29(847 x 622 x 737) 163(74)
Specifications are subject to change without notice. 441 51 1421 00 2/3/15
PRODUCT SPECIFICATIONS Gas Furnace: N8MXL
MODEL NUMBER IDENTIFICATION GUIDE
DIGIT POSITION 1 2 3 4 5 6,7,8 9.10 11.12 13 14
N 8 M X L 045 14 12 A 1
N=Entry
8=80% AFUE EFFICIENCY
M=Multi position POSITION
V=Variable Speed Blower Motor-ECM
X=ECM Blower Motor
S=Single-stage
T=Two-stage TYPE
N=Standard
L=Low NOx FEATURE
045=44,000 BTU/hr
070=66,000 BTU/hr
090=88,000 BTU/hr
110= 110,000 BTU/hr
135=132,000 BTU/hr HEAT INPUT
14=14-3/16"
17=17-1/2"
21 =21"
24=24-1/2" CABINET WIDTH
12=1200 CFM
14=1400 CFM
16=1600 CFM
20=2000 CFM
22=2200 CFM NOMINAL MAXIMUM COOLING AIRFLOW @.5 IN.W.C.
SALES MAJOR REVISION DIGIT
ENGINEERING WINUH AFVISION DIGIT
ECM-Electronically Commutated Motor
ACCESSORIES PART NUMBER IDENTIFICATION GUIDE
DIGIT POSITION 1 2 3 4 5,6,7 8,9 10, 11
N A H A 001 01 DH
N =Non-Branded BRANDING
A=Accessory PRODUCT GROUP
H=Heating KIT USAGE
A=Original
B=2nd Generation MAJOR SERIES
Product Identitler Number
Package Quantity
Type of Kit(Example: DH=Draft Hood-Chimney Adapter)
2 Specifications subject to change without notice. 441 51 1421 00
PRODUCT SPECIFICATIONS .--) Gas Furnace: NSMn
PHYSICAL DATA
NATURAL GAS O451412A 0701712A 0701716A 0901714A 0902116A 1102120A 1352420A
INPUT BTUH* Upflow 44,000 66,000 66,000 88,000 88,000 110,000 132,000
Hz/Downflow 42.000 63,000 63,000 84,000 84,000 105,000 126,000
OUTPUT Upflow 36,000 54,000 54,000 71,000 72,000 90,000 107,000
CAPACITY BTUH*
(Nonweatherized ICS)t Hz/Downflow 34,000 51,000 51,000 68,000 68,000 85,000 102,000
AFUE t* Nonweatherized ICS 80.0 80.0 80.0 80.0 80.0 80.0 80.0
TRANSFORMER(24 volt) 40 VA
CERTIFIED TEMP RISE RANGE- 30-60 35-65 25-55 40-70 35-65 30-60 40-70
°F VC) (17-33) (19-36) (14-31) (22-39) (19-36) (17-33) (22-39)
CERTIFIED EXT Heating .10 .12 .12 .15 .15 .20 .20
STATIC
PRESSURE Cooling .50 .50 .50 .50 .50 .50 .50
AIRFLOW CFM# Heating 710 982 1205 1203 1418 1890 1760
Cooling 1080 1 1005 1 1435 1 1210 1 1445 1 2040 1 1810
LIMIT CONTROL SPST
HEATING BLOWER CONTROL Solid-State Time Operation
BURNERS(Monoport) 2 3 3 4 4 5 6
GAS CONNECTION SIZE 1/2 inch NPT
GAS VALVE(Redundant)Manufac-
turer White-Rodgers
Minimum Inlet Pressure(in.w.c.) 4.5(Natural Gas)
Maximum Inlet Pressure(in.w.c.) 13.6(Natural Gas)
IGNITION DEVICE Hot Surface
COOLING CAPACITY CFM range(.5 in.w.c.) 430-1080 385-1005 875-1435 750-1210 845-1445 990-2040 1025-1810
* Gas input ratings are certified for elevations to 2000 ft.(610 M).In USA,for elevations above 2000 ft.(610 M),reduce ratings 4 percent for each 1000 ft.(305 M)above
sea level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1-2009 Table F.4 or furnace Installation Instructions.
t Capacity in accordance with U.S.Government DOE test procedures.
f Airflow shown is for bottom only return-air supply in comfort mode(as shipped).For air delivery above 1800 CFM,see Air Delivery Table for other options.A filter is
required for each return-air supply.
ICS-Isolated Combustion System
ELECTRICAL DATA
Operating
Volts- Voltage*Range Minimum Maximum Maximum
FURNACE Hertz- Maxi- Mini- Maximum Unit Wire Size Wire Length$ Fuse or CKT
MODEL Phase mum mum Unit-Amps Ampacity# AWG ft(m) BKRt Amps
0451412 115-60-1 127 104 5.6 1.8 14.0 41.0 (14.3) 15.0
0701712 115-60-1 127 104 5.6 7.8 14.0 47.0 (14.3) 15.0
0701716 115-60-1 127 104 10.0 13.3 14.0 27.0 (8.2) 15.0
0901714 115-60-1 127 104 8.2 111.0 14.0 33.0 00.11) 15.0
U9U2116 115-6U-1 127 l U4 8.2 11.0 14.0 33.0 i (10.1) 15.0
1102120 115-60-1 127 104 13.4 17.4 12.0 33.0 (10.1) 20.0
1352420 115-60-1 127 104 10.7 14.0 14.0 26.0 (7.9) 15.0
*Permissible limits of the voltage range at which the unit operates satisfactorily.
t Time-delay type is recommended.
$Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop.
441 51 1421 00 Specifications subject to change without notice 3
PRODUCT SPECIFICATIONS Gas Furnace: N8MXL
UNIT DIMENSIONS
a; a; Y �
a1 U
m N
tEE = L
aid a) EE'� a) a I
NID
� �_
aX °IEaX:_.
o X co c E cFw a&' m_ -
o oD(D C) -
Y=-0 co(D c) O X y
m CD a) al 1 1
0c cc(nY _b
-0 @(D.N c 6 30 _ a a, q L
y
iC 5 roc
oE au)'Ernwal �° •�'
r N O
a) 0O XX_ ro
N X
a)
O � ¢
N ul 0 E tF
a3 O C�
a) O O O'5 E N es r
a) ftz E a C C y O O �
5E 0 oo — - pit
8022
> o
� EE 8a) E0 •i
�
R
ENyEEEgE.2
E0)- Eao m LL w
NN s NID OLo()O
C) O
O =
E c O m
` O
C a)
-0� lC f2 N N � N !
E r� O u0000000000u
fa a 7 LL LL 0 O ?
LL U - c I 000�0000000� s� -�
�L1oo � as
E E X o N(D E E o0000000000o k3w.
66 f�tl E w aD�� 7 y U I -
W o 3:= N ll ll ll Cc N Mo00000000000
al L U
ZrNC7
o
- cc
3.
u -u o N� -
1 1- I J—.1- l— I
! O ��a I f •b 1 -- 1
Iry O % r - - -;W-I
'92
o
rv_ o
o 0
a ul s
I a of
F I m
L L
._ 1 1 r
SD4963-4
G D
CABINET WIDTH OUTLET WIDTH P AND BOTTOM BOTTOM INLET VENT
IN(MM) IN(MM) OUTLET WIDTH CONNECTION SHIP WT
N8MXL IN(MM) IN(MM) SIZE LB(KG)
0451412 14-3/16(360) 12-9/16(319) 9-5J16(23 12- 1 16 32 4 104(47)
0701712A 17-1/2(445) 15-7/8(403 1-916 294) 16-1/8(410) 4 126(57)
0701716 17-1/2(445) 15-7/8(403 11-9/16(294 1 -1 6 4 0 4 126 57)
0901714A 17-1/2 445) 15-7/8 140M i -9 16 294 16-1/8(410) 4 127(58)
0902 6 2/ 3 19-3/8 492) f 3-5 16(338 19-1/2(495) 4 140(64j
1102120 21 18-3/8(492) 13-5/16(338) i9-iJ2(495) 4 152(69)
1352420A 24-1/2 2) 1 22-7/8(581) - 8 23 84 4t 163(74
t 135 Btu/h size furnaces require 5 inch(127 mm)vents. Use a 4-5 inch(102-127 mm)vent adaptor between furnace and vent stack.
See installation instructions for complete installation requirements.
4 Specifications subject to change without notice. 441 51 1421 00
PRODUCT SPECIFICATIONS Gas Furnace: N8MXL
DOWNFLOW VENT CONFIGURATIONS
JW
i
�j
i
O 0
.p.
SEE NOTES:1,2,4,5,7,8,9 a02061 SEE NOTES: ,8,9 nozosz
SEE NOTES:1,2,3,4,5,7,8,9 A02063
1,2,4,5,6,7
DOWNFLOW CONTINUTED UPFLOW VENT CONFIGURATIONS
uuu
.hr
o
0 O
•O-
t
SEE NOTES:1,2,3,4,5,7,8,9 A02060 SEE NOTES:1,2,4,7,8,9 n0205e SEE NOTES:1,2,3,4,7,8,9
HORIZONTAL RIGHT VENT CONFIGURATIONS
lLj.
SEE NOTES:1,2,4,5,7,8,9 A0WJ SEE NOTES:1,2,4,7,8,9 A02069
SEE NOTES:1,2,4,5,7,8,9 n02070
HORIZONTAL LEFT VENT CONFIGURATIONS
SEE NOTES,1,2,4,7,8,9 A02064 ES:1,2,4,5,7,8,9 SEE NOTES:1,2,4,5,7,8,9 nozoss
SEE NOT no2ass
HORIZONTAL LEFT VENT CONFIGURATIONS
O
SEE NOTES:1,2,4,5,7,8,9 A02067
441 51 1421 00 Specifications subject to change without notice. 5
PRODUCT SPECIFICATIONS Gas Furnace: N8MXL
Venting Notes
1. For common vent, vent connector sizing and vent material: United States-use the NFGC.
2. Immediately increase to 5 inch (127 mm) or 6-inch (152 mm) vent connector outside furnace casing when 5 inch (127 mm) vent
connector is required, refer to Note 1 above.
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when
Downflow Vent Guard Kit, is used in the downflow position.
4. Type-B vent where required, refer to Note 1 above.
5. 4 inch single-wall (26 ga. min.)vent must be used inside furnace casing and when the Downflow Vent Guard Kit is used external
to the furnace.
6. Accessory Downflow Vent Guard Kit, required in downflow installations with lower vent configuration.
7. Chimney Adapter Kit may be required for exterior masonry chimney applications. Refer to Chimney Adapter Kit, for sizing and
complete application details.
8. Secure vent connector to furnace elbow with (2) corrosion-resistant sheet metal screws, spaced approximately 180' apart.
9. Secure all other single wall vent connector joints with (3) corrosion resistant screws spaced approximately 120' apart. Secure
Type-B vent connectors per vent connector manufacturer's recommendations.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS FOR ALL UNITS
This forced air furnace is equipped for use with natural gas at
altitudes 0- 10,000 ft(0-3,050m). t Clearance arrows
An accessory kit, supplied by the manufacturer, shall be used to r. do not change with
convert to propane gas use or may be required for some natural furnace orientation.
gas applications.
This furnace is for indoor installation in a building constructed on BACK "7
site.
The furnace may be installed on combustible flooring in alcove or Fa°°� s�
closet at minimum clearance as indicated by the diagram from
combustible material.
This furnace may be used with a Type B-1 Vent and may be
e
vented in common with other gas fired appliances. 01
This furnace is approved for UPFLOW, DOWNFLOW, and `U
HORIZONTAL installations, t Clearance in inches
Downflow Positions: Vent Clearance to combustibles:
t Installation on non—combustible floors only. For Single Wall vents 6 inches(6 po).
For Installation on combustible flooring only when installed on special base or coil assembly. For Type B 1 vent type 1 inch(1 po).
0 18 inch front clearance required for alcove.
* Indicate supply or return sides when furnace is in the horizontal
position. Line contact only permissible between lines formed by
intersections of the Top and two Sides of the furnace jacket, and
building joists,studs or framing.
BLOWER PERFORMANCE DATA
N8MXL 0451412 0701712 0701716 0901714 0902116 1102120 1352420
DIRECT-DRIVE MOTOR Hp(ECM) 1/3 1/3 3/4 1/2 1/2 1 3/4
MOTOR FULL LOAD AMPS 4.4 4.4 8.8 6.8 6.8 11.5 8.8
RPM (Nominal)—Speeds 1050-5 1050-5 1050-5 1050-5 1050-5 1050-5 1050-5
BLOWER WHEEL DIAMETER 10 x 6 11 x 8 11 x 8 11 x 8 10 x 10 11 x 11 11 x 11
WIDTHS—in (mm) (254 152) (279 x 203) (279 x 203) (279 x 203) (254 x 254 (279 x 279 (279 x 279
6 Specifications subject to change without notice. 441 51 1 421 00
PRODUCT SPECIFICATIONS --., --) Gas Furnace: N8LIXL
AIR DELIVERY-CFM with filter)*
WIRE- Test Airflow Delivery @ Various External Static Pressures(in.w.c.)
UNIT SIZE LEAD SPEED
COLOR 0.1 0.2 0.3 1 0.4 0.5 O 66 0.7 0.8 0.9 1
Gray 5 1230 ii9u 1155 1120 1080 1045 lulu 975 935 895
Yellow 4 980 945 920 890 855 815 770 735 690 645
0451412 Urange 3 77u 72U ti85 4 600 560 520 475 4iu 385
Clue 2 710 660 620 580 540 490 455 415 375 335
Red 1 buu 540 500 455 415 385 345 305 235 --
Gray 5 1185 1140 1095 1055 1005 960 915 865 820 780
Yellow 4 1000 940 895 850 800 750 695 650 600 555
0701712 tine 3 990 935 895 845 790 740 690 640 590 535
Orange 2 855 775 720 660 605 560 495 435 385 335
Red 1 860 685 515 445 385 34U 275 2u5 -- --
Gray 5 1610 1565 1525 1475 1435 1395 1350 1305 1260 1215
Yellow 4 1385 1335 1290 1250 1205 1165 1125 1075 1U25 98u
0701716 Clue 3 1215 ii65 112U 1075 1035 985 940 895 845 840
Orange 2 1175 1130 1085 1035 990 945 900 855 805 760
Red 1 1080 1U15 955 920 875 820 780 725 670 620
Gray 5 1355 1320 1285 1245 1210 1165 1125 Iudu 1025 815
Yellow 4 1295 1255 1220 1185 1140 1100 1055 1005 955 815
0901714 CIUe 3 1220 1185 1150 111L)5 lUbb 1025 975 915 840 740
Orange 2 1030 985 940 900 845 79U 715 655 59U 535
Red i 945 905 855 800 75U 67U 6U0 5440 49U 435
Gray 5 1625 1580 1535 1490 1445 1395 1340 1260 1135 995
Clue 4 1440 1395 1350 1305 1255 1200 1145 1090 1040 950
0902116 Yellow 3 1425 1380 1335 1290 1235 1185 1125 10/5 W20 940
Urange 2 12bU 121U 116U 11U5 1050 990 935 880 820 755
Red ___1_7 1095 1040 98 9 5 84 780 72U 65U 585 520
Gray 5 2255 2205 2150 2100 2040 1985 1920 1835 1735 1615
Yellow 4 1600 1525 1465 1400 1335 1275 1210 1150 1080 1015
1102120 Blue 3 1945 1890 1830 1770 1715 1655 1600 1545 1480 1430
Orange 2 1420 1340 1280 200 1140 1 65 1005 925 865 790
Red 1 1280 1205 1140 1055 9-M 910 840760 695 630
Gray 5 2065 2005 1940 1875 1$10 1740 1670 1600 153U 1470
Blue 4 1825 1 76U 1695 1630 15 0 1490 1 2U 1' Su i 275 12U5
r1352420 Yellow 3 1760 1690 1625 1555 1485 1415 1345 1275 1000 1135
Urange 2 1620 1550 1480 1405 1335 12 1195 1130 1065 995
_qed 1 1
NOTES:
1. A filter is required for each return-air inlet. Airflow performance includes a 3/4 in. (19 mm) washable filter media such as
contained in factory-authorized accessory filter rack. See accessory list. To determine airflow performance without this filter,
assume an additional 0.1 in. W.C. available external static pressure.
2. ADJUST THE BLOWER SPEED TAPS AS NECESSARY FOR THE PROPER AIR TEMPERATURE RISE FOR EACH
INSTALLATION.
3. Highlighted areas indicate airflow range is beyond the range allowed for heating. THESE AIRFLOW RANGES MAY ONLY BE
USED FOR COOLING.
--Indicates unstable operating conditions.
441 51 1421 00 Specifications subject to change without notice. 7
PRODUCT SPECIFICATIONS Gas Furnace: NBMXL
0
N
le
1N x x x x x x x x x
T
0
N
r
T
to
CM f
x x x x x x x x x
0
c x x x x x x x x x
O
0
c x x x x x x x x x
0
0
N
T
c x x x x x x x x x
N
x x x x x x x x x
0
y `o
1C a) a)
y c c c c ar ca
V m m a) m m t
rn
Q a) a) N a) —
O
l0 (d l0 Id U UN7
L L L L
f0 ltl N l0 O O O1
3 3 3 3 0 0 °
L L L L O 2
C C C C > Q
in to u) u� a) aa)) '�CD
N N N N C >
X X X X t C a
CO N N 3 a) y
Y Y p d Y
U U U U ICS -aO
a o. U) Y
C C N
I\ N N = n n m
T T O_ N a) N in
ai 'c
N N 0 (D O O > > ; > L 0
X X v z L)
m M fL m — N L!7 N N Z 1 0 0 T A
N x O LP)
m m m m -0c E X co m m m
E E E E T '- U Y Y o c �. --EL EL o Z m C
0 v = = = � U a) a) 'Ca MO 0- 1
� N N
O O O O 1 0
0 I N E M
C C C C L L LL LL 2 CO
O C C C
V N (d N 7, ccO
y a) a) m a) w w v E 3 3 E E o m 2 m
c w LL w w in �n c i -0 C) U v z a .� .o
N0
LU LLLL ILL LL L LLILLL m m LLLL LLLL m U 2 2 Q o a)
m LL (LLO �O (n > 0 J z N— a
O TO O TO 0 O O O O O O O O TO v v
0 0 0 0 0 O O O O O co p 0 U O as
z O O O O 0 O O O O O O O O 00
m m m m Q Q Q Q Q m Q Q Q
Lr = _ _ _ _ _ _ _ _ _
_ _
Q a a Q a Q ¢ Q a Q a Q a Q Q
a z z z z z z z z z z z z z z x�«
8 Copyright 2015 International Comfort Products 441 51 1421 00
Lewisburg,Tennessee 37091 USA
www.GoAirquest.com
Home ' F.spaFiol Contact
kjAft 1)1j)arrrre111 of A,-Z,Index Help my I'm
Labo'r & 1ndLJstries
Safety&Health o t Workplace Rights .d . v
Washington State Department of
" Labor & Industries
B L WILSON COMPANY
Owner or tradesperson 6810 SILVANA TERRACE RD
Principals STANWOOD,WA 98292
360-652-6974
WILSON,BROCK LEONARD,OWNER SNOHOMISH County
Doing business as
B L WILSON COMPANY
WA UBI No. Business type
601 381 377 Individual
Governing persons
BROCK
LEONARD
WILSON
CAROL J WILSON;
License
Verify the contractor's active registration/license/certification(depending on trade)and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
BLWILC"075LP
Effective—expiration
06/17/1993—09/17/2020
Bond
WESTERN SURETY CO $12,000.00
Bond account no.
24345420
Received by L&I Effective date
05/09/2002 05/26/2002
Expiration date
Until Canceled
Insurance
Ohio Security Ins Co $1,000,000.00
Policy no.
BKS54577132
Received by L&I Effective date
08/02/2018 09/17/2017
Expiration date
09/17/2019
Insurance history
Savings
.. ........... ....
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
No L&I tax debts are recorded for this contr *license during the previous 6 year period,but son bts
may be recorded by other agencies.
License Violations
No license violations during the previous 6 year period.
Workers' comp
Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums.
L&I Account ID Account is current.
260,833-00
Doing business as
HEAT KING MECHANICAL
Estimated workers reported
Quarter 4 of Year 2018"Less than 1 Workers"
L&I account contact
T3/STEPHANIE HENDERSON(360)902-5598-Email:HSTE235@lni.wa.gov
Public Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
No strikes have been issued against this contractor.
Contractors not allowed to bid
No debarments have been issued against this contractor.
Workplace safety and health
No inspections during the previous 6 year period.
�1Yashin�lon`�
Help us improve
K•DSUPPLY
FACILITIES MAINTENANCE
SMARTCOMFORT By Carrier 2 Ton 14 SEER Air Conditioner
Southwest Region
Sign in for price
Iflllllll j, PART 282449
C'!�fll{III{IiiiNli{ �l i it' BRAND CARRIER
r,�L11111 I��Il�1i�111 i�ll��ll�,l,��
QUANTITY
PLEASE NOTE
Free Shipping
In lower 48 states
Q NEXT-DAY DELIVERY
HASSLE-FREE RETURNS
Product Details
• SmartComfort® by Carrier 2 Ton 14 SEER Air Conditioner For Southwest Region
• 208/230 Volt,1-Phase,60 Hz
• Scroll Compressor
• Copper Tube,Aluminum Fin Coil
• Easy Access Service Valves
• External High And Low Refrigerant Service Ports
• Only Two Screws To Access Control Panel
• Factory Charged With R-410A Refrigerant
• Pre-Painted Cabinet Finish Over Galvanized Steel
• 3/8"Grille Spacing For Extra Protection
• 10 Year Warranty With Timely Registration
• 2 Year No Hassle Replacement Limited Warranty
• AHRI Certified -Underwriters Lab (UL) Listed
• Mfg#R4A524GKB
California residents:Prop 65 Warnings
Prnrii irrt cnPrc n
Assembled Dimensions
Weight 123
HazMat
Hazardous No
Packaging Dimensions
Weight Measure LB
Weight 123.000
Size Measure IN
Width 26.500
Height 32.063
Length 26.500
Weights & Dimensions
Width 26.5
Height 32.063
Make & Model
UNSPSC 40101701
Brand Carrier
Manufacturer Part No R4A524GKB
Warranty
Warranty 5
Product Features
TAA/BAA Compliant Yes
FOB No
AbilityOne No
i
,�
i
i
I-
ADA Approved No
ENERGY STAR® Compliant No
GSA Approved No
UL Listed No
Specifications
Voltage Rating 208/230
Country of Origin MEXICO
Phase 1
SEER Rating 14
Made in the USA No
Related Searches
general electric replacement
air handler ceiling mount
air conditioner cover outdoor
115 volt window air conditioner
ge wall air conditioner
outdoor air conditioner
Related Products
PART 259261 PART 259459 PART 260561
Friedrich 10,000 BTU 230 Volt GE 11,600 BTU 230 Volt High Mount LG 11,800 BTU 230 Vc
Heat/Cool Wall Air Conditioner Wall Air Conditioner Conditioner
'Air��
� N
i
r-I�i v X XAmok
�Cy pCp £ J Q f G ¢ Z a Y
mmmm O �ln
k \ B! Q tyo
i-JZO i v
a � 3 (�4 ry
O ,T drD
nF w�
e '� ¢• .d. Z � � 77. z � D o_ .� a � IJ
W A .q G. a^ i .•gyp -i C a = A C ^
D F}r T
� ° Z3� E t c O � p 70� T s '� •-� d '�
�v
- oO
u "' NVJOm 3 _� p c P Cal y o =
r/oi �� Jr . vi N s > � O o�ryy/ F j m
tn
if
80 a 3 E
is - r� •
f Zm
4 i
i _
RESIDENTIAL MECHANICAL
PERMIT APPLICATION
Department of Community&Economic Development
City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551
THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND
OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION
AND INCLUDE ALL INFORMATION.
Project Address. / ` -,s J �&4— A l
Project Description: /J Al2 JL
Owner: �LA-AEL7Fr! I
Address: ,3/,5 L City: 1 State: Zip Code:
Phone: S,. �?CG �kz_ - 4 fj_ Email:
Applicant: t. yY1�-
Address: City: State: Zip Code:
Phone: Email:
CONTRACTOR INFORMATION
Contractor Name: EL
s 6� J
Address: 10(� j p �51 )) }4 — airy: s� State:�,f� Zip Code:
License Number: ?LtcU�_' D %-5 4_ f- Expiration:
Phone: Email: s l '1� J '4 _/� 'fsl�
STAFF USE O
Permit#: LJ Z'��(p Accepted b Date:APR 012019
6/16LP Page 1 of 2
RESIDENTIAL MECHANICAL
PERMIT APPLICATION
IN
,O Department of Community&Economic Development
City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551
SELECT ALL PROPOSED APPLIANCES
`l /�i�,� Z. �L t'
Furnace (80+) Model# i '`�`- I� AFUE
❑ Heat Pump Model# AFUE HSPE
AC Unit Model # SEER
Freestanding Stove iJ Fire Place Insert Outdoor BBQ
Gas Piping ❑ Solid-Fuel Appliance ❑ Other
Gas Piping Information
Not Applicable: ❑'
Pipe Material:
Pipe Size
Distance from Meter to Furthest Appliance:
Total BTU's of all Appliances:
• New gas piping requires a pressure test hooking to any appliance
• Sediment traps (drips) are required on all gas lines
• Gas lines are required to be supported/secured every 6 to 8 feet
• Proper Combustion air and venting required for all appliances
• A shut-off valve is required within 6 feet of all appliances
Applicant Signature: - Date:
Applicant Printed Name:
1 hereby certify that the above information is correct and that the construction, installation for the above mentioned
property will be in accordance with the applicable laws of the City of Arlington and the State of Washington.
6/16LP Page 2 of 2
A 1w 1W@ N8MXL
1 0 Product Specifications
80% ECM Single Stage Heating Furnace
EASIER TO SELL
• 80%AFUE `
• Supports two-stage cooling units
• Flame roll-out sensors standard
• Category I venting
• Blocked vent switch :
• Dehumidification feature in cooling
• 24 VAC humidifier terminal
• Electronic air cleaner terminal
• N8MXL model California NOx approved ,
• Certified to leak 2 percent or less of nominal air conditioning
CFM delivered when pressurized to 1-inch Water Gauge with all
present air inlets, air outlets, and condensate drain port(s) sealed
TOUGHER
• ECM blower motor
•Adjustable heating blower OFF delay
• Factory set blower ON delay
• RPJ aluminized steel heat exchanger
• High temperature limit control prevents overheating
• Direct ignition with Silicon Nitride ignitor Illustrations and photographs are only representative.
• One piece prepainted steel cabinet Some product models may vary.
QUIETER
• In-shot burners
• Insulated blower compartment WARNING
EASIER TO INSTALL AND SERVICE This turnace is not designed for use in mobile homes,
• 33 1/3" (847mm) high,for ease of installation trailers, or recreational vehicles. Such use could
• Innovative knobs for easy door removal and secure attachment result in property damage and/or death.
• Factory shipped for natural gas,with propane
gas conversion kits available it
• Four position- upflow/downflow/horizontal (left/right)
CERTIFIED-
installation
•Three position vent elbow capability
•Through the casing flue pipe for counterflow applications Use of the A's p Certified Tin Mark indicates a
9 9 P P Pp manufacturer's participation in the program.For
• Common venting with other Category I appliances IA
verification of certification for individual products,
• Masonry chimney adapter availablego to www.ahridirectory.org.
• Self diagnostics ISO 9001 DESIGN
• Slide out blower assembly omi-sa cis
WARRANTY
• 20 year heat exchanger limited warranty
• 10 year parts limited warranty with timely registration
• 5 year parts limited warranty if not registered within 90 days of original installation
* For residential applications only. See warranty certificate for complete details and restrictions, including
warranty coverage for other applications.
Input Efficiency Cooling Capacity Dimensions H x W x D Shipping Wt.
Model Size (MBTUH) AFUE CFM range Inches(Millimeters) Lbs(Kg)
9.5 in.w.c.(125 Pa)
N8MXL 0451412 44,000 80% 415-1080 33-1/3 x 14-3/16 x 29(847 x 360 x 737) 104(47)
N8MXL 0701712 66,000 80% 385-1005 33-1/3 x 17-1/2 x 29(847 x 445 x 737) 126(57)
N8MXL 0701716 66,000 80% 875-1435 33-1/3 x 17-1/2 x 29(847 x 445 x 737) 126(57)
N8MXL 0901714 88,000 80% 750-1210 33-1/3 x 17-1/2 x 29(847 x 445 x 737) 127(58)
N8MXL 0902116 88,000 80% 845-1445 33-1/3 x 21 x 29(847 x 533 x 737) 140(64)
N8MXL 1102120 110,000 80% 990-2040 33-1/3 x 21 x 29(847 x 533 x 737) 152(69)
N8MXL 1352420 132,000 80% 1025- 1810 33-1/3 x 24-1/2 x 29(847 x 622 x 737) 163(74)
Specifications are subject to change without notice. 441 51 1421 00 2/3/15
PRODUCT SPECIFICATIONS Gas Furnace: N8MXL
MODEL NUMBER IDENTIFICATION GUIDE
DIGIT POSITION 1 1 2 1 3 1 4 1 5 1 6,7,8 1 9,10 1 11,12 1 13 1 14
NJ 8 1 M I X I L 1 045 1 14 1 12 1 A 1 1
N=Entry
8=80% AFUE EFFICIENCY
M=Multiposition POSITION
V=Variable Speed Blower Motor-ECM
X=ECM Blower Motor
S=Single-stage
T=Two-stage TYPE
N=Standard
L=Low NOx FEATURE
045=44,000 BTU/hr
070=66,000 BTU/hr
090=88,000 BTU/hr
110= 110,000 BTU/hr
135=132,000 BTU/hr HEAT INPUT
14=14-3/16"
17=17-1/2"
121 =21"
24=24-1/2" CABINET WIDTH
12= 1200 CFM
14= 1400 CFM
16= 1600 CFM
20=2000 CFM
22=2200 CFM NOMINAL MAXIMUM COOLING AIRFLOW @.5 IN.W.C.
SALES (MAJOR) REVISION DIGIT
ENGINEERING MINOR REVISION DIGIT
ECM-Electronically Commutated Motor
ACCESSORIES PART NUMBER IDENTIFICATION GUIDE
DIGIT POSITION 1 2 3 4 5,6,7 8,9 10, 11
N A H A 001 01 DH
N=Non-Branded BRANDING
A=Accessory PRODUCT GROUP
H=Heating KIT USAGE
A=Original
B=2nd Generation MAJOR SERIES
Product Identifier Number
Package Quantity
Type of Kit(Example: DH=Draft Hood-Chimney Adapter)
2 Specifications subject to change without notice. 441 51 1421 00
PRODUCT SPECIFICATIONS Gas Furnace: N8MXL
PHYSICAL DATA
NATURAL GAS O451412A 0701712A 0701716A 0901714A 0902116A 1102120A 1352420A
INPUT BTUH* Upflow 44,000 66,000 66,000 88,000 88,000 110,000 132,000
Hz/Downflow 42,000 63,000 63,000 84,000 84,000 105,000 126,000
OUTPUT Upflow 36,000 54,000 54,000 71,000 72,000 90,000 107,000
CAPACITY BTUH*
(Non weatherized ICS)t Hz/Downflow 34,000 51,000 51,000 68,000 68,000 85,000 102,000
AFUE t* Nonweatherized 80.0 80.0 80.0 80.0 80.0 80.0 80.0
ICS
TRANSFORMER(24 volt) 40 VA
CERTIFIED TEMP RISE RANGE- 30-60 35-65 25-55 40-70 35-65 30-60 40-70
°F(°C) (17-33) (19-36) (14-31) (22-39) (19-36) (17-33) (22-39)
CERTIFIED EXT Heating .10 .12 .12 .15 .15 .20 .20
STATIC
PRESSURE Cooling .50 .50 .50 .50 .50 .50 .50
Heating 710 982 1205 1203 1418 1890 1760
AIRFLOW CFM# Cooling 1080 1005 1 1435 1210 1445 2040 1810
LIMIT CONTROL SPST
HEATING BLOWER CONTROL Solid-State Time Operation
BURNERS(Monoport) 2 3 3 4 4 5 6
GAS CONNECTION SIZE 1/2 inch NPT
GAS VALVE(Redundant)Manufac-
White-Rodgers
turer
Minimum Inlet Pressure(in.w.c.) 4.5(Natural Gas)
Maximum Inlet Pressure(in.w.c.) 13.6(Natural Gas)
IGNITION DEVICE Hot Surface
COOLING CAPACITY CFM range 430-1080 385-1005 875-1435 750-1210 845-1445 990-2040 1025-1810
(.5 in.w.c.)
* Gas input ratings are certified for elevations to 2000 ft.(610 M).In USA,for elevations above 2000 ft.(610 M),reduce ratings 4 percent for each 1000 ft.(305 M)above
sea level.Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1-2009 Table F.4 or furnace Installation Instructions.
t Capacity in accordance with U.S.Government DOE test procedures.
# Airflow shown is for bottom only return-air supply in comfort mode(as shipped).For air delivery above 1800 CFM,see Air Delivery Table for other options.A filter is
required for each return-air supply.
ICS-Isolated Combustion System
ELECTRICAL DATA
Operating
Volts- Voltage*Range Minimum Maximum Maximum
FURNACE Hertz- Maxi- Mini- Maximum Unit Wire Size Wire Length# Fuse or CKT
MODEL Phase mum mum Unit Amps Ampacity# AWG ft(m) BKRt Amps
0451412 115-60-1 127 104 5.6 7.8 14.0 47.0 (14.3) 15.0
0701712 115-60-1 127 104 5.6 7.8 14.0 47.0 (14.3) 15.0
0701716 115-60-1 127 104 10.0 13.3 14.0 27.0 (8.2) 15.0
0901714 115-60-1 127 104 8.2 11.0 14.0 33.0 (10.1) 15.0
0902116 115-60-1 127 104 8.2 11.0 14.0 33.0 (10.1) 15.0
1102120 115-60-1 127 104 13.4 17.4 12.0 33.0 (10.1) 20.0
1352420 115-60-1 127 104 10.7 14.0 14.0 26.0 1 (7.9) 15.0
*Permissible limits of the voltage range at which the unit operates satisfactorily.
t Time-delay type is recommended.
$Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop.
441 51 1421 00 Specifications subject to change without notice. 3
Gas Furnace: N8MXL
UNIT DIMENSIONS
�F
C = -r- c -
C P
N m
s0+
y 01 L d a n¢ F
N O E E O i-. w
E f67io � �?
-a-0 Y E� _ a o �w
Qx 4) Ev x rnp � N
<o _
oz2 E,n xco c E �Nw &� "ooN N
ID
XSv1N N I�
C U C
.O'O @ M C 6 3 � O
>!.c�r 0_ m 3
cz 6 C r r O E o —
O E N L�,
N O O x X* _ N
O w X N N m—, rcy
C N r r a)w LD N LLw
p OVrr O >.t2 F o "wooPIE
L N O 7 — ¢ O'
C 0 0•`— E N m �?
o m oa Y�
0
EEEc3 3 „g
cz o 0 2 0 > O
EyyEEEgE2
a�N�omoMU o
Ec06 cSc2
-� c6 CCONN > C 0. _
cu 0 7 E 2 LL .y O ®00000000000u z
cc, ���oor < m OODU�UDDDDDO ono
E x o N to E E a< ODUUUDDDDDDO k3
WcoEA- Z!:o : o 0
W g 0:__ 0)LLLLLLCcN� ®u00000000000
l'-0 c w
Z r N M U O oz
x
0
00 �
\ —VU � W
L
� N 0 ""m
-a_ ��w 9d_N
fJ > —
u a < a s
o
o a m Nk
N a io
SD4963-4
A B C D
CABINET WIDTH OUTLET WIDTH TOP AND BOTTOM BOTTOM INLET VENT
IN(MM) IN(MM) OUTLET WIDTH CONNECTION SHIP WT
N8MXL IN(MM) IN(MM) SIZE LB(KG)
0451412A 14-3/16(360) 12-9/16(319) 9-5/16(237) 12-11/16(322) 4 104(47)
0701712A 17-1/2(445) 15-7/8(403) 11-9/16(294) 16-1/8(410) 4 126(57)
0701716A 17-1/2(445) 15-7/8(403) 11-9/16(294) 16-1/8(410) 4 126(57)
0901714A 17-1/2(445) 15-7/8(403) 1 11-9/16(294) 1 16-1/8(410) 4 127(58)
0902116A 21 (533) 19-3/8(492) 1 13-5/16(338) 1 19-1/2(495) 4 140(64)
1102120A 21 (533) 19-3/8(492) 13-5/16(338) 19-1/2(495) 4 152(69)
1352420A 24-1/2(622) 22-7/8(581) 15-1/16(383) 23(584) 4 t 163(74)
t 135 Btu/h size furnaces require 5 inch(127 mm)vents. Use a 4-5 inch(102-127 mm)vent adaptor between furnace and vent stack.
See installation instructions for complete installation requirements.
4 Specifications subject to change without notice. 441 51 1421 00
PRODUCT SPECIFICATIONS Gas Furnace: N8MXL
DOWNFLOW VENT CONFIGURATIONS
llLL17�
1---- llLLLLll
I
I l Fi I
II il E] I
O
I
I O O
I
e I
I e e e
I
I
I
p'
p. ,p,
I
I
I
I
I
I
I
I
I
SEE NOTES:1,2,4,5,7,8,9 A02061 SEE NOTES:1,2,3,4,5,7,8,9 A02063
SEE NOTES:1,2,4,5,6,7,8,9 Aozosz
DOWNFLOW CONTINUTED UPFLOW VENT CONFIGURATIONS
llLLLLLL
o o e I I
II E
'III�
O
O O
.p.
SEE NOTES:1,2,3,4,5,7,8,9 A02060 SEE NOTES:1,2,4,7,8,9 A02058 SEE NOTES:1,2,3,4,7,8,9 A02059
HORIZONTAL RIGHT VENT CONFIGURATIONS
o O
O
i.
i
�� i �ii III Ili 11I Ei I �
o°
. P.. :
SEE NOTES:1,2,4,5,7,8,9 A02070 SEE NOTES:1,2,4,5,7,8,9 A02068 SEE NOTES:1,2,4,7,8,9 A02069
HORIZONTAL LEFT VENT CONFIGURATIONS
uLLLU Lu
�11 1III
0 0 0
O O O
°° o
SEE NOTES:1,2,4,7,8,9 AUUM SEE NOTES:1,2,4,5,7,8,9 A02066
SEE NOTES:1,2,4,5,7,8,9 A02065
HORIZONTAL LEFT VENT CONFIGURATIONS
1II IuEi
II EI I
O
O
SEE NOTES:1,2,4,5,7,8,9 A02067
441 51 1421 00 Specifications subject to change without notice. 5
PRODUCT SPECIFICATIONS Gas Furnace: N8MXL
Venting Notes
1. For common vent, vent connector sizing and vent material: United States-use the NFGC.
2. Immediately increase to 5 inch (127 mm) or 6-inch (152 mm) vent connector outside furnace casing when 5 inch (127 mm) vent
connector is required, refer to Note 1 above.
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when
Downflow Vent Guard Kit, is used in the downflow position.
4. Type-B vent where required, refer to Note 1 above.
5. 4 inch single-wall (26 ga. min.) vent must be used inside furnace casing and when the Downflow Vent Guard Kit is used external
to the furnace.
6. Accessory Downflow Vent Guard Kit, required in downflow installations with lower vent configuration.
7. Chimney Adapter Kit may be required for exterior masonry chimney applications. Refer to Chimney Adapter Kit, for sizing and
complete application details.
8. Secure vent connector to furnace elbow with (2) corrosion-resistant sheet metal screws, spaced approximately 180° apart.
9. Secure all other single wall vent connector joints with (3) corrosion resistant screws spaced approximately 120° apart. Secure
Type-B vent connectors per vent connector manufacturer's recommendations.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS FOR ALL UNITS
This forced air furnace is equipped for use with natural gas at
altitudes 0- 10,000 ft(0-3,050m). Clearance arrows
An accessory kit, supplied by the manufacturer, shall be used to 5m, do not change with
furnace orientation.
convert to propane gas use or may be required for some natural w
gas applications. °,.
This furnace is for indoor installation in a building constructed on BAc 5 *o°
site. K
The furnace may be installed on combustible flooring in alcove or F�°�' S
closet at minimum clearance as indicated by the diagram from ERVI CE
combustible material. 5`° FR°Nr za°
MIN
This furnace may be used with a Type B-1 Vent and may be ° � m
vented in common with other gas fired appliances.
This furnace is approved for UPFLOW, DOWNFLOW, and o„
HORIZONTAL installations. t Clearance in inches
Downflow Positions: Vent Clearance to combustibles:
t Installation on non—combustible floors only. For Single Wall vents 6 inches(6 po).
For Installation on combustible flooring only when installed on special For Type B-1 vent type 1 inch(1 po).
base or coil assembly.
0 18 inch front clearance required for alcove.
* Indicate supply or return sides when furnace is in the horizontal
position. Line contact only permissible between lines formed by
intersections of the Top and two Sides of the furnace jacket, and
building joists,studs or framing.
BLOWER PERFORMANCE DATA
N8MXL 0451412 0701712 0701716 0901714 0902116 1102120 1352420
DIRECT-DRIVE MOTOR Hp (ECM) 1/3 1/3 3/4 1/2 1/2 1 3/4
MOTOR FULL LOAD AMPS 4.4 4.4 8.8 6.8 6.8 11.5 8.8
RPM (Nominal)—Speeds 1050-5 1050-5 1050-5 1050-5 1050-5 1050-5 1050-5
BLOWER WHEEL DIAMETER 10 x 6 11 x 8 11 x 8 11 x 8 10 x 10 11 x 11 11 x 11
WIDTHS— in (mm) (254 152) 1 (279 x 203) 1 (279 x 203) 1 (279 x 203) (254 x 254 (279 x 279 (279 x 279
6 Specifications subject to change without notice. 441 51 1421 00
PRODUCT SPECIFICATIONS Gas Furnace: N8MXL
AIR DELIVERY-CFM (with filter)*
WIRE- Test Airflow Delivery @ Various External Static Pressures(in.w.c.)
UNIT SIZE LEAD SPEED
COLOR 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Gray 5 1230 1190 1155 1120 1080 1045 1010 975 935 895
Yellow 4 980 945 920 890 855 815 770 735 690 645
0451412 range 3 770 720 685 640 600 560 520 475 430 385
Blue 2 710 660 620 580 540 490 455 415 375 335
Red 1 600 540 500 455 415 1 385 345 305 235 --
ray 5 1185 1140 1095 1055 1005 960 915 865 820 780
Yellow 4 1000 940 895 850 800 750 695 650 600 555
0701712 Blue 3 990 935 895 845 790 740 690 640 590 535
Orange 2 855 775 720 660 605 560 495 435 385 335
Red 1 860 685 515 445 385 340 275 205 -- --
ray 5 1610 1565 1525 1475 1435 1395 1350 1305 1260 1215
Yellow 4 1385 1335 1290 1250 1205 1165 1125 1075 1025 980
0701716 Blue 3 1215 1165 1120 1075 1035 985 940 895 845 840
Orange 2 1175 1130 1085 1035 990 945 900 855 805 760
Red 1 1080 1015 955 920 875 820 780 725 670 620
Gray 5 1355 1320 1285 1245 1210 1165 1125 1080 1025 815
Yellow 4 1295 1255 1220 1185 1140 1100 1055 1005 955 815
0901714 Blue 3 1220 1185 1150 1105 1065 1025 975 915 1 840 740
Orange 2 1030 985 940 900 845 790 715 655 590 535
Red 1 3 945 905 855 800 750 670 600 540 490 435
Gray 5 1625 1580 1535 1490 1445 1395 1340 1260 1135 995
Blue 4 1440 1395 1350 1305 1255 1200 1145 1090 1040 950
0902116 Yellow 3 1425 1380 1335 1290 1235 1185 1125 1075 1020 940
Orange 2 1260 1210 1160 1105 1050 990 935 880 820 755
Red 1 3 1095 1040 980 905 845 780 720 650 585 520
Gray 5 2255 2205 2150 2100 2040 1985 1920 1835 1735 1615
Yellow 4 1600 1525 1465 1400 1335 1275 1210 1150 1080 1015
1102120 Blue 3 1945 1890 1830 1770 1715 1655 1600 1545 1480 1430
Orange 2 1420 1340 1280 1200 1140 1065 1005 925 865 790
Red 1 1280 1205 1140 1055 990 910 840 760 695 630
Gray 5 2065 2005 1940 1875 1810 1740 1670 1600 1530 1470
Blue 4 1825 1760 1695 1630 1560 1490 1420 1350 1275 1205
1352420 Yellow 3 1760 1690 1625 1555 1485 1415 1345 1275 1200 1130
Orange 2 1620 1550 1480 1405 1335 1260 1195 1130 1065 995
Red 1 1325 1260 1185 1100 1025 955 885 805 735 670
NOTES:
1. A filter is required for each return-air inlet. Airflow performance includes a 3/4 in. (19 mm) washable filter media such as
contained in factory-authorized accessory filter rack. See accessory list. To determine airflow performance without this filter,
assume an additional 0.1 in. W.C. available external static pressure.
2. ADJUST THE BLOWER SPEED TAPS AS NECESSARY FOR THE PROPER AIR TEMPERATURE RISE FOR EACH
INSTALLATION.
3. Highlighted areas indicate airflow range is beyond the range allowed for heating. THESE AIRFLOW RANGES MAY ONLY BE
USED FOR COOLING.
-- Indicates unstable operating conditions.
441 51 1421 00 Specifications subject to change without notice. 7
PRODUCT SPECIFICATIONS Gas Furnace: NBMXL
jx x x x x x x x x
�
N
§ x x x x x x x x x
(D
§ x x x x x x x x x
@
/
2 x x x x x x x x x
0
�
2 x x x x x x x x x
0
CM
2 x x x x x x x x x
0
�
/ x x x x x x x x x
0
Cn
\ 7
Q
in
Q J J J J 3 /
« \ \ \ \ -
a a a a 0 £ \
n n n n
\ \ \ \ \ \ 0
R R R R / e »
_ = W
> <
\ a)/
x x x x ± = E \
2 / - ° a
J J ^ ^ Z \ \ \f
k \ CL � \ \ ) 2 2 ) q
& k \ \ r r \ ƒ } ) \ \ j\
S S . . / x 0 " > > % % = 8
k k k k / 3 m \ _ T T ( ( \\
^ x ] 7 # m o 0
2 \ I n $ 2 m ¥ 2\
E E E E '- '- f =
S J § G ) / 0-
0 ] )
z 2 2 2 / % g + E { \ \ e z )f
{ { { 0 E E _ _ ° / _ _ j a/
c c c c m m & _ < < o
& k k k k a a / / \ f / t 0 J } \\
Q E E E E 2 2 M M _ t = _ @ n a) co
w f f f f G G / f \ \ \ / = ] / \ {7
0 u u u u 4 4 a a o = c / / z E a 9=
cc
LL z z L 2 = z z c o I I £ \ /a@
w LL E LL LL E LL E LL m > _ = u z 2 ±
§ 0 0 0 0 / 0 0 0 G G G G G G §G a
r c w = m w o o n # n = c %
o 0 0 o 0 o 0 0 0 0 0 </LL
z o 0 0 o e o G G G o 0 0 0 0
e c c c c < < < < < c < < _ _
ƒ ƒ ƒ ƒ ƒ ƒz z z z z z z z z z z z z z x
ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ w«
8 Copyright 20 15Inmym&C«o,Rwus 41511410
G_Wy Tennessee pm1USA
_som»ymm
CITY OFARLINGTON
238 N. OLYMPIC AVE - ARLINGTON, WA. 98223
PHONE; (360) 403-3551
BUILDING PERMIT
Address:19313 46th Ave NE Permit#•2486
Parcel#:00928200009500 Valuation:0.00
OWNER APPLICANT CONTRACTOR
Name:HILL ERIC S&HEATHER MARZEC Name:Heat King Mechanical Name:Heat King Mechanical
Address: 19313 46TH AVE NE Address:6810 Silvana Terrace Rd Address: 11330 4th Ave West
City,State Zip:ARLINGTON,WA 98223 City,State Zip:Stanwood,WA 98292 City,State Zip:Everett,WA 98204
Phone: Phone:425-409-4661 Phone:425-409-4661
LIC: EXP:
MECHANICAL CONTRACTOR PLUMBING CONTRACTOR
Name:Heat King Mechanial Name:
Address: 1130 4th Ave W. Address:
City,State,Zip:Everett,WA 98204 City,State,Zip:
Phone:425-409-4661 Phone:
LIC#:BLWILC*075LP EXP: 09/17/2020 LIC#: EXP:
JOB DESCRIPTION
-
PERMIT TYPE: Residential Mechanical CODE YEAR: 2015
STORIES: CONST.TYPE:
DWELLING UNITS: OCC GROUP:
BUILDINGS: OCC LOAD:
PERMIT APPROVAL
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY;
NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S
COMPENSATION INSURANCE AND RCW 18.27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR
A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBCI10/IRC110.
SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City ofArling n st be reported n your sales tax turn f rm
and coded City of Arlington#3101.
Z �
Signature Print Name Date I By Date
CONDITIONS
3" Concrete pad with seismic bracing attached. Provide electrical disconnect.Lines shall be insulated; use of
adhesive tapes are prohibited. Adhere to approved appliance. Call for final inspection.
THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION
ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION.
PERMIT FEES
Date Description Fee Amount
4/2/2019 A/C Unit $25.00
4/2/2019 Furnace $25.00
4/2/2019 Mechanical Permit Base Fee $25.00
4/2/2019 Processing/Technology Fee $25.00
Total Due: $100.00
Total Payment: $0.00
Balance Due: $100.00
CALL FOR INSPECTIONS
BUILDING(360)403-3417
When calling for an inspection please leave the following information:
Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon
HOSUPPLY
FACILITIES MAINTENANCE
SMARTCOM FORT By Carrier 2 Ton 14 SEER Air Conditioner
Southwest Region
Sign in for price
lu IIIIIII��I �I�I i�� !, PART 282449
�I11111 illllliilllllllllll,llll'i BRAND CARRIER
I , 111111�11 IIlJI�
w� ,Ifllllllllll�lll!lIIII!lIIIIIIIIII
n�� ►is�� ` E I�Illll�uluullllill�;;
I IIII�I�Ilill �lllllllllll�,, QUANTITY
III IIIII �IIIIIIIIIIIIII
IIIIIIIIIIIIIIIIII,
:I�Illlllllf��illllllll -
PLEASE NOTE
Free Shipping
In lower 48 states
NEXT-DAY DELIVERY
HASSLE-FREE RETURNS
Product Details
• SmartComfort® by Carrier 2 Ton 14 SEER Air Conditioner For Southwest Region
• 208/230 Volt,1-Phase,60 Hz
• Scroll Compressor
• Copper Tube,Aluminum Fin Coil
• Easy Access Service Valves
• External High And Low Refrigerant Service Ports
• Only Two Screws To Access Control Panel
• Factory Charged With R-410A Refrigerant
• Pre-Painted Cabinet Finish Over Galvanized Steel
• 3/8"Grille Spacing For Extra Protection
• 10 Year Warranty With Timely Registration
• 2 Year No Hassle Replacement Limited Warranty
• AHRI Certified -Underwriters Lab (UL) Listed
• Mfg#R4AS24GKB
QCalifornia residents: Prop 65 Warnings
Product Specs Q
Assembled Dimensions
Weight 123
HazMat
Hazardous No
Packaging Dimensions
Weight Measure LB
Weig ht 123.000
Size Measure IN
Width 26.500
Height 32.063
Length 26.500
Weights & Dimensions
Width 26.5
Height 32.063
Make & Model
UNSPSC 40101701
Brand Carrier
Manufacturer Part No R4A524GKB
Warranty
Warranty 5
Product Features
TAA/BAA Compliant Yes
FOB No
AbilityOne No
Certifications & Standards
ADA Approved No
ENERGY STAR® Compliant No
GSA Approved No
U L Listed No
Specifications
Voltage Rating 208/230
Country of Origin MEXICO
Phase 1
SEER Rating 14
Made in the USA No
Related Searches
general electric replacement
air handler ceiling mount
air conditioner cover outdoor
115 volt window air conditioner
ge wall air conditioner
outdoor air conditioner
Related Products
PART 259261 PART 259459 PART 260561
a
KEE-
--mac � •-
Friedrich 10,000 BTU 230 Volt GE 11,600 BTU 230 Volt High Mount LG 11,800 BTU 230 V<
Heat/Cool Wall Air Conditioner Wall Air Conditioner Conditioner
Sign in for price Sign in for price Sign in for price
Permit#: 2486
Permit Date: 04/01/19
Permit Type: RESIDENTIAL MECHANICAL
Project Name: Hill/Marzec
Applicant Name: Heat King Mechanical
Applicant Address: 6810 Silvana Terrace Rd
Applicant, City, State, Zip: Stanwood, WA 98292
Contact: Gene Markus
Phone: 425-409-4661
Email: silvanacrest77@msn.com
Scope of Work: Replace furnace - install 2 ton AC unit
Valuation: 0.00
Square Feet: 0
Number of Stories: 0
Construction Type:
Occupancy Group:
ID Code:
Permit Issued: 04/23/2019
Permit Expires:
Form Permit Type:
Status: LASERFICHE
Assigned To: Raelynn Jones
Property
Parcel# Address Legal Description Owner Name Owner Phone Zoning
HILL ERIC S&
00928200009500 19313 46TH AVE NE HEATHER Residence
Single Family
-Detached
MARZEC
Contractors
Contractor Primary Contact Phone Address Contractor Type License License#
Heat King Mechanical Brock Wilson 425-409-4661 11330 4th Ave MECHANICAL Labor&Industries BLWILC*075LP
West CONTRACTOR
Fees
Fee Description Notes Amount
Air Cond.Unit Btu/h<100>; $25.00
Btu/hp>500
Forced Air Heat fee per Btu $25.00
Mechanical Base Permit Fee $25.00
Processing/Technology $25.00
Credit Card Service $3.00
Total $103.00
Attached Letters
Date Letter Description
04/02/2019 Building Permit
Payments
Date Paid By Description Payment Type Accepted By Amount
04/22/2019 brock wilson 74990530 iTransactCC $100.00
04/22/2019 CC Surcharge CC Surcharge Raelynn Jones $3.00
#74990530
Outstanding Balance $0.00
Notes
Date Note Created By:
04/01/2019 Emailed for clarification of A/C model number Raelynn Jones
Uploaded Files
Date File Name
04/24/2019 4800700-2486 Signed permit.jpg
04/02/2019 4709896-2486 SMARTCOMFORT By Carrier 2 Ton 14 SEER Air Conditioner-Southwest Region HD Supply..pdf
04/01/2019 4706799-2486 Apnlication.pdf
04/01/2019 4706800-2486 Furnace specs.pdf