Loading...
HomeMy WebLinkAbout216 W JENSEN ST_BLD2476_2026 CITY OF ARLINGTON l 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:216 W.Jensen St Permit#:2476 Parcel#:00560600000601 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:TATON TIMOTHY M/JENNIFER E Name:CM Heating Name:CM Heating Inc Address:PO BOX 2381 Address:1415 Broadway Address: 1415 Broadway 1 City,State Zip:SNOHOMISH,WA 98291 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 LIC: EXP: ` MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address:1415 Broadway Address: 1 City,State,Zip:Everett,WA 98201 City,State,Zip: 1 Phone:425-259-0550 Phone: LIC#:CMHEAMH877DN EXP: 03/15/2021 LIC#: EXP- JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: 1 PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/1RC110. SALES TA) ICE:Sales tax relating to constriction and construction materials in the City of Arlington mast be reported on your sales tax return fomt d dcd Y ity llington#3101. Lon Signature Print Name Dale ICa y Date CONDITIONS 3" Concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shalt be insulated; use of adhesive tapes are prohibited. Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZE ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 3/28/2019 Heat Pump $25.00 3/28/2019 Mechanical Permit Base Fee $25.00 3/28/2019 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon NOTICE TO PERMITEE AND/OR OWNER ❑ ,PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY APPROVED PERMIT#: LOT# DATE: JOB ADDRESS: Lo TYPE OF INSPECTION: 'l ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK: MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 Cl CALL FOR REINSPECTION LD 1 THEACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 _ - 1 INSPECTOR DATE t' IBUILDING DEPT. ' o PLANNING DEPT. CITY OF ARLINGTON '�:, /�- INSPECTION REPORT ¢ti1N GTO Permit No.:O-.� - . 6 Aot c Address: Contractor: IN C'�O Owner: Date: / J-APPROVAL ❑ PARTIAL APPROVAL ❑ VIOLATION ❑ CORRECTION REQUESTED ❑ Corrections listed below MUST BE MADE before work can be approved. ❑ Please contact inspector. ❑ Was not able to perform inspection. ❑ CALL 435-0674 FOR RE-INSPECTION -24 hour notice required. Inspector: 4 i 1_ Date: TYPE OF INSP16CTION REQUESTED ❑ Under-floor ❑ Framing ❑ Gas Piping ❑ Footing ❑ Drywall, Nailing ❑ Consultation ❑ Foundation ❑ Shear Nailing ❑ Groundwork ❑ Mechanical ❑ Grid ❑ Struct. Slab ❑ Wood Stove ❑ Rough-in 0 Final ❑ Masonry ❑ Drainage ❑ Insulation ❑ Other: i � I i CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 7 PHONE; (360)403-3551 E BUILDING PERMIT j Address:216 W.Jensen St Permit#:2476 Parcel#:00560600000601 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:TATON TIMOTHY M/IENNIFER E Name:CM I leafing Name:CM Heating Inc i Address:PO BOX 2381 Address:]415 Broadway Address: 1415 Broadway City,State Zip:SNOHOMISH,WA 98291 City,Slate Zip:Everett,WA 98201 City,Slate Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 + LIC: EXP: ` MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address:1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone; LIC M CMHEAMH877DN EXP: 63/15/2021 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT 1S UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110l1RC 110. SALES'r 1 E:Sales lax relating to constriction and construction materials in the City of Arlington musl be reported on your sales tax return fomt Eodcd ity i f gton#310t. Signature PrintNamc Dale Ica cd y Datc CONDITIONS 3" Concrete pad with seismic bracing attached. Provide electrical disconnect.Lines shall be insulated; use of adhesive tapes are prohibited.Adhere to approved appliance. Call for final inspection, THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION, PERMIT FEES Date Description Fee Amount 3/28/2019 Heat Pump $25.00 3/28/2019 Mechanical Permit Base Fee $25,00 3/28/2019 Processing/Technology Fee $25,00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number;Type of Inspection being requested,and whether you prefer morning or afternoon ,� 1 GiTY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 ` PHONE; (360) 403-3551 BUILDING PERMIT Address:216 W.Jensen St Permit#:2476 Parcel#:00560600000601 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:TATON TIMOTHY M/JENNIFER E Name:CM Heating Name:CM Heating Inc Address:PO BOX 2381 Address:1415 Broadway Address: 1415 Broadway City,State Zip:SNOHOMISH,WA 98291 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 LIC: EXP: MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address: 1415 Broadway Address: City,State,Zip: Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC#:CMHEAMH877DN EXP: 03/15/2021 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRCI10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date cica ed y Date CONDITIONS 3" Concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated; use of adhesive tapes are prohibited. Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 3/28/2019 Heat Pump $25.00 3/28/2019 Mechanical Permit Base Fee $25.00 3/28/2019 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon .. I Permit Information Date 3/28/2019 Permit Number 2476 Project Name CM Heating-216 W.Jensen St Applicant Name CM Heating Applicant Address 1415 Broadway City,State,Zip Everett,WA 98201 Contact Phone 425-259-0550 Email kailana@cmheating.com Permit Type Residential Mechanical Site Address 216 W.Jensen St Valuation 0.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Residential Mechanical Number of Stories 0 Proposed Use 2 Zone ductless HP install Assigned To Raelynn Jones Property Parcel Address Legal Owner Owner Phone Zoning D0560600000601 1216 W JENSEN ST I ITATON TIMOTHY M/JENNIFER E 1111 Single Family Residence-Detached Contractors Contractor Name Primary Contact Phone Email Contractor Type License =icense CM Heating Inc Debbie Bauers 125-259-05501debbie cmheatin .com UECHANICAL CONTRACTOR -abor&Industries OMHEAMH8776N Fees Fee Description Notes Amount Heat Pum 322.10.00.00 $25.00 Mechanical Permit Base Fee 322.10.00.00 $25.00 Processing/Technology Fee 341.43.00.02 $25.00 Total $75.00 Uploaded Files Upload File Date File Uploaded B 3/28/2019 1:18:23 PM 2476 Application.pdf Jones, Raelynn �[ 3/28/2019 1:18:23 PM 2476 Attachments.pdf Jones, Raelynn RESIDENTIAL MECHANICAL =� PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:216 WESTJENSEN ST Project Description:2 ZONE DUCTLESS HEAT PUMP INSTALL Owner: JENNIFERTATON Address: 216 WJENSEN ST City:ARLINGTON State WA Zip Code: 98223 Phone: 360-632-1247 Email;Taton_ranch@msn.com Applicant: CM HEATING - KAILANA MONIZ Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 Phone: 425-259-0550 Email: KAILANA@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:CM HEATING Address; 1415 BROADWAY City. EVERETT _ State WA Zip Code: 98201 License Number;CMHEAI*095R4 f Expiration: 05-03-19 Phone:425-259-0550 Email:KAILANA@CMH EATING.COM STAFF USE ON Y Received Permit #: T,1J Iglu Accepted by: - Date: MAg 2 19- 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) Model # AFUE JCS Heat Pump Model #MXZ2C20NA2 AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance fj Other Gas Piping Information Not Applicable: 15 Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date 03/27/2019 Applicant Printed Name: KAILANA MONIZ I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 1.5-TON MULTI-ZONE INVERTER HEAT-PUMP SYSTEM At ELECTRIC Job Name: System Reference: Date: .Ali(Illlllllllllll�lllllllli�ill, � l�llll Ilfl[<II�IIIIlllll�IIIIIIII °,iili(IIIIIllulil�pi�ll' GENERAL FEATURES • Variable speed INVERTER-driven compressor • Energy Star°certifiedl (non-ducted) • M-NET connection through outdoor unit • Quiet outdoor unit operation as low as 50 dB(A) • New Intelligent Power Module (IPM)for reduced power loss • Selectable thermal lockout/restart function • Optional base pan heater • High pressure switch for additional protection • Thermal differential of+/-1° F from setpoint Received MAR 2 7 2019 'ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Specifications are subject to change without notice. ©2018 Mitsubishi Electric US,Inc. • 1 I Outdoor Model numberIndoor Ducted Maximum Capacity Btu/h 20,000 Rated Capacity Btu/h 18,000 19,000 20,000 Cooling*1 Minimum Capacity Btu/h 5,700 Maximum Power Input W 2,245 Rated Power Input W 1,417 1,709 2,000 Power Factor % 98.7 99.3 99.9 Maximum Capacity Btu/h 25,000 Rated Capacity Btu/h 22,000 Minimum Capacity Btu/h 7,400 Heating at 47° F*2 Maximum Power Input W 2,455 Rated Power Input W 1,641 1,706 1,771 Power Factor % 96.2 97.9 99.6 Maximum Capacity Btu/h 15,500 15,000 14,500 Heating at 17° F*3 Rated Capacity Btu/h 12,500 13,000 13,500 Maximum Power Input W 1,750 1,780 1,810 Rated Power Input W 1,300 1,325 1,350 Heating at 5° F*4 Maximum Capacity Btu/h 11,100 11,000 10,900 Maximum Power Input W 1,600 1,625 1,650 SEER 20.00 18.00 16.00 EER*1 12.70 11.35 10.00 HSPF (IV) 10.00 9.65 9.30 Efficiency COP at 47° F *2 3.93 3.78 3.64 COP at 17° F *3 2.82 2.87 2.93 ENERGY STAR®Certified YES NO NO Voltage, Phase, Frequency 208/230V, 1-phase, 60 Hz Electrical Guaranteed Voltage Range V AC 187-253 Voltage: Indoor-Outdoor, S1-S2 V AC 208V/230 Voltage: Indoor-Outdoor, S2-S3 V DC 12-24 Voltage: Indoor-Remote controller V DC 24 Recommended Fuse/Breaker Size A 20 Specifications are subject to change without notice. ©2018 Mitsubishi Electric US,Inc. SPECIFICATIONS: Outdoori IndoorModel number unit type Non- Mix Ducted Ducted Recommended Wire Size AWG AWG14 (Indoor-Outdoor) MCA A 17.2 Fan Motor Full Load Amperage A 1.77 Fan Motor Output W 64 Airflow Rate CFM 1,342/ 1,458 Refrigerant Control Liner Expansion Valve Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling*1 dB(A) 50 Sound Pressure Level, Heating*2 dB(A) 54 Compressor Type Twin Rotary type Compressor Model SNB140FQUH2T Compressor Motor Output kW 1.5 Outdoor unit Compressor Rated Load Amps A 10.7 Compressor Locked Rotor Amps A 15.5 Compressor Oil Type//Charge oz. NEO22/20.3 External Finish Color Munsell 3.OY 7.8/1.1 Base Pan Heater Optional W: In. [mm] 33-1/16 [840] Unit Dimensions D: In. [mm] 13 [330] H: In. [mm] 27-15/16 [710] W: In. [mm] 40 [1,010] Package Dimensions D: In. [mm] 18-1/2 [470] H: In. [mm] 33-1/2 [850] Unit Weight Lbs. [kg] 126 (57] Package Weight Lbs. [kg] 147 [67] Cooling Intake Air Temp °F 14 to 115 (Maximum /Minimum) Outdoor unit operating temperature range Heating Intake Air Temp OF 5 to 75 (Maximum /Minimum) Thermal Lock-out/Re-start Temperatures OF Cooling: 10.4/ 14 Heating: 1.5/5 Specifications are subject to change without notice. ©2018 Mitsubishi Electric US,Inc. I , Outdoor unit MXZ-2C20NA2 IndoorModel number Ducted Type R410A Refrigerant Charge Lbs., Oz. 3, 15 Maximum Number of Connected IDU 2 Minimum Number of Connected IDU 2 Indoor unit connection Maximum connected capacity Btu/h 24,000 Minimum connected capacity Btu/h 12,000 Gas Pipe Size O.D. (Flared) In. [mm] 3/8 [9.52] Liquid Pipe Size O.D. (Flared) In. [mm] 1/4 [6.35] Total Piping Length Ft. [m] 164 [50] Maximum Height Difference, Piping ODU above IDU Ft. [m] 33[10] Maximum Height Difference, Ft. [m] 49 [15] ODU below IDU Farthest Piping Length from ODU to IDU Ft. [m] 82 [25] Maximum Number of Bends 50 AHRI Rated *1 Cooling (Indoor//Outdoor) OF 80°F DB, 67°F WB//95°F DB, 75°F WB Conditions (Rated *2 Heating at 47°F (Indoor//Outdoor) °F 70°F DB, 60oF WB//47-F DB, 43°F WB data is determined at a fixed *3 Heating at 17°F (Indoor//Outdoor) OF 70°F DB, 60°F WB// 17°F DB, 15°F WB compressor speed) Conditions *4 Heating at YF (Indoor//Outdoor) °F 70oF DB, 60°F WB//-4°F DB, -5°F WB For reference to connected capacity charts, please refer MXZ-2C20NA2-U1 Operational Performance. Notes: Specifications are subject to change without notice. ©2018 Mitsubishi Electric US,Inc. ACCESSORIES: I Port Adapter size: 3/8"x 5/8" ❑ PAC-SG76RJ-E Port Adapter size: 1/4"x 3/8" ❑ PAC-493PI Joint Pipe Port Adapter size: 3/8"X 1/2" ❑ MAC-A454JP-E Port Adapter size: 1/2"X 3/8" ❑ MAC-A455JP-E Port Adapter size: 1/2" X 5/8" ❑ MAC-A456JP-E Air Discharge Guide ❑ MAC-856SG Base Pan Heater ❑ PAC-646BH-E Control Cable ❑ CW162S 3-pole Disconnect ❑TAZ-MS303 M-NET Adapter ❑ PAC-IF01 MNT-E Wall Mounting Bracket(Powder-coated Steel) ❑ QSWB2000M-1 Wall Mounting Bracket(316 Series Stainless Steel) ❑ QSWBSS Outdoor Unit Mounting Pad 24"x 42"x 3" ❑ ULTRILITE2 MiniSplit Mounting Stand-Dual Fan models- 12" ❑ QSMS1202M MiniSplit Mounting Stand-Dual Fan models- 18" ❑ QSMS1802M MiniSplit Mounting Stand-Dual Fan models-24" ❑ QSMS2402M 1/4 x 1/2 x 15'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MLS141212T-15 1/4 x 1/2 x 30'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MLS141212T-30 1/4 x 1/2 x 50'/ 1/2"Lineset(Twin-Tube Insulation) ❑ MLS141212T-50 1/4 x 1/2 x 65'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MLS141212T-65 1/4 x 1/2 x 100'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MLS141212T-100 Diamondback Linesets" 3/8 x 5/8 x 10'/1/2" Lineset( )Twin-Tube Insulation ❑ MPLS385812T-10 3/8 x 5/8 x 15'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MPLS385812T-15 3/8 x 5/8 x 30'/1/2" Lineset(Twin-Tube Insulation) ❑ MPLS385812T 30 3/8 x 5/8 x 50'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MPLS385812T-50 3/8 x 5/8 x 65'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MPLS385812T-65 3/8 x 5/8 x 100'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MPLS385812T-100 Linesets are indoor unit specific and will be listed in the IDU information -the Joint Pipe adaptors are used in this application Specifications are subject to change without notice ©2018 Mitsubishi Electric US,Inc. DIMENSIONS: I Unit: inch (mm) 2•&16 � �plfel b Airinlel ^ 3-e11-511 fi"I Drain hole VOutlel I3W. 1 s•0WW W* umnaxwneawi� 1 I 7716' '1•1/92• it t y _ ID 2•tenr d = %W — W , aD 20132 1.FREE SPACE � a � 3-15fUr'or noro 3 2 d. n N s • I]4V32'aI more 2.SERVICE SPACE 9 �N�aee rleef MITSUBISHI o k� AAW ELECTRIC r COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com F--44f WIT in FORM#MXZ-2C20NA2-201805 Intertek Specifications are subject to change without notice. ©2018 Mitsubishi Electric US,Inc. Saarch L&ISEARCH • Safety&Health Claims&Insurance Workplace R• Trades Washington State Department of Labor & Industries C M HEATING INC Owner or tradesperson 1415 BROADWAY Principals EVERETT,WA 98201 425-259-6666 Garner,James N,PRESIDENT SNOHOMISH County Umayam,John A,VICE PRESIDENT Umayam,Antonio(Tony)G,SECRETARY • Umayam,Antonio(Tony)G,TREASURER ■ Garner,James N,AGENT ■ Garner,Paul, PRESIDENT (End:06/29/2016) • Garner,Kathleen D,SECRETARY (End:06/29/2016) ■ Garner,Kathleen D,TREASURER (End:06/29/2016) Doing business as C M HEATING INC WA UBI No. Business type 601 114 652 Corporation Governing persons JAMES GARNER PAUL M GARNER; KATHLEEN GARNER; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. CMHEAMH877DN Effective—expiration 03/15/2013—03/15/2021 Designated administrator Active. Giacomi,John Meets current requirements. License type License no. Electrical Administrator GIACOJ`840MG Bond Contractors Bonding&Insurance Co $4,000.00 Bond account no. SC6810 Received by L&I Effective date 03/15/2013 02/28/2000 Expiration date Until Canceled .Savings ..................... No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. i Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 490,794-01 Doing business as CHIMNEY MASTERS Estimated workers reported Quarter 4 of Year 2018"51 to 75 Workers" L&I account contact T1 I NICHOLE CAROW(360)902-5634-Email:CANI235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/16/2015 No violations Inspection no. 317935327 Location 1415 Broadway Everett,WA 98201 \camas Help us improve �11`ashinglanw Job Name: System Reference: Date: 11 _: �alllllllllllllllllllllllllll��. iiilillllllllllllllllllllllllllllllllllil ummmmuuunumnmiwuur 'IIIIIII�;iiillllllllllliiiilllllllll'' GENERAL FEATURES • Variable speed INVERTER-driven compressor • Energy Star°certified' (non-ducted) • M-NET connection through outdoor unit • Quiet outdoor unit operation as low as 50 dB(A) • New Intelligent Power Module (IPM)for reduced power loss • Selectable thermal lockout/restart function • Optional base pan heater • High pressure switch for additional protection • Thermal differential of+/-1° F from setpoint 1ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Specifications are subject to change without notice. ©2018 Mitsubishi Electric US, Inc. SPECIFICATIONS: MXZ-2C20NA2 Outdoor DuctedModel number Indoor unit type Non- Mix Ducted Maximum Capacity Btu/h 20,000 Rated Capacity Btu/h 18,000 19,000 20,000 Cooling*1 Minimum Capacity Btu/h 5,700 Maximum Power Input W 2,245 Rated Power Input W 1,417 1,709 2,000 Power Factor % 98.7 99.3 99.9 Maximum Capacity Btu/h 25,000 Rated Capacity Btu/h 22,000 Minimum Capacity Btu/h 7,400 Heating at 47' F*2 Maximum Power Input W 2,455 Rated Power Input W 1,641 1,706 1,771 Power Factor % 96.2 97.9 99.6 Maximum Capacity Btu/h 15,500 15,000 14,500 Rated Capacity Btu/h 12,500 13,000 13,500 Heating at 17' F *3 Maximum Power Input W 1,750 1,780 1,810 Rated Power Input W 1,300 1,325 1,350 Maximum Capacity Btu/h 11,100 11,000 10,900 Heating at 5° F *4 Maximum Power Input W 1,600 1,625 1,650 SEER 20.00 18.00 16.00 EER*1 12.70 11.35 10.00 HSPF (IV) 10.00 9.65 9.30 Efficiency COP at 47' F *2 3.93 3.78 3.64 COP at 17° F *3 2.82 2.87 2.93 ENERGY STAR®Certified YES NO NO Voltage, Phase, Frequency 208/230V, 1-phase, 60 Hz Electrical Guaranteed Voltage Range V AC 187-253 Voltage: Indoor- Outdoor, S1-S2 V AC 208V/230 Voltage: Indoor-Outdoor, S2-S3 V DC 12-24 Voltage: Indoor- Remote controller V DC 24 Recommended Fuse/Breaker Size A 20 Specifications are subject to change without notice. ©2018 Mitsubishi Electric US, Inc. SPECIFICATIONS: MXZ-2C20NA2 Outdoor unit MXZ-2C20NA2 Model number Indoor unit type Non- Mix Ducted Recommended Wire Size AWG AWG14 (Indoor- Outdoor) MCA A 17.2 Fan Motor Full Load Amperage A 1.77 Fan Motor Output W 64 Airflow Rate CFM 1,342/ 1,458 Refrigerant Control Liner Expansion Valve Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling*1 dB(A) 50 Sound Pressure Level, Heating*2 dB(A) 54 Compressor Type Twin Rotary type Compressor Model SNB140FQUH2T Compressor Motor Output kW 1.5 Outdoor unit Compressor Rated Load Amps A 10.7 Compressor Locked Rotor Amps A 15.5 Compressor Oil Type H Charge oz. NEO22/20.3 External Finish Color Munsell 3.OY 7.8/1.1 Base Pan Heater Optional W: In. [mm] 33-1/16 [840] Unit Dimensions D: In. [mm] 13 [330] H: In. [mm] 27-15/16 [710] W: In. [mm] 40 [1,010] Package Dimensions D: In. [mm] 18-1/2 [470] H: In. [mm] 33-1/2 [850] Unit Weight Lbs. [kg] 126 [57] Package Weight Lbs. [kg] 147 [67] Cooling Intake Air Temp OF 14 to 115 (Maximum/ Minimum) Outdoor unit operating Heating Intake Air Temp OF 5 to 75 temperature range (Maximum/ Minimum) Thermal Lock-out/ Re-start Temperatures OF Cooling: 10.4/ 14 Heating: 1.5/5 Specifications are subject to change without notice. ©2018 Mitsubishi Electric US, Inc. SPECIFICATIONS: MXZ-2C20NA2 Outdoor unit MXZ-2C20NA2 Model number Indoor unit type Non- Mix Ducted Ducted Type R410A Refrigerant Charge Lbs., Oz. 3, 15 Maximum Number of Connected IDU 2 Minimum Number of Connected IDU 2 Indoor unit connection Maximum connected capacity Btu/h 24,000 Minimum connected capacity Btu/h 12,000 Gas Pipe Size O.D. (Flared) In. [mm] 3/8 [9.52] Liquid Pipe Size O.D. (Flared) In. [mm] 1/4 [6.35] Total Piping Length Ft. [m] 164 [50] Maximum Height Difference, Piping ODU above IDU Ft. [m] 33 [10] Maximum Height Difference, Ft. [m] 49 [15] ODU below IDU Farthest Piping Length from ODU to IDU Ft. [m] 82 [25] Maximum Number of Bends 50 AHRI Rated *1 Cooling (Indoor H Outdoor) OF 80OF DB, 670F WB H 950F DB, 750F WB Conditions (Rated *2 Heating at 470F (Indoor H Outdoor) OF 70OF DB, 60OF WB H 470F DB, 430F WB data is determined at a fixed *3 Heating at 170F (Indoor//Outdoor) OF 70°F DB, 60°F WB H 17°F DB, 15°F WB compressor speed) Conditions *4 Heating at 5°F (Indoor H Outdoor) OF 70°F DB, 60°F WB H-4°F DB, -5°F WB For reference to connected capacity charts, please refer MXZ-2C20NA2-U1 Operational Performance. Notes: Specifications are subject to change without notice. ©2018 Mitsubishi Electric US, Inc. ACCESSORIES: ' 1 Port Adapter size: 3/8"x 5/8" ❑ PAC-SG76RJ-E Port Adapter size: 1/4"x 3/8" ❑ PAC-493PI Joint Pipe Port Adapter size: 3/8"X 1/2" ❑ MAC-A454JP-E Port Adapter size: 1/2" X 3/8" ❑ MAC-A455JP-E Port Adapter size: 1/2" X 5/8" ❑ MAC-A456JP-E Air Discharge Guide ❑ MAC-856SG Base Pan Heater ❑ PAC-646BH-E Control Cable ❑ CW162S 3-pole Disconnect ❑ TAZ-MS303 M-NET Adapter ❑ PAC-IF01 MNT-E Wall Mounting Bracket(Powder-coated Steel) ❑ QSWB2000M-1 Wall Mounting Bracket(316 Series Stainless Steel) ❑ QSWBSS Outdoor Unit Mounting Pad 24"x 42"x 3" ❑ ULTRILITE2 MiniSplit Mounting Stand-Dual Fan models- 12" ❑ QSMS1202M MiniSplit Mounting Stand-Dual Fan models- 18" ❑ QSMS1802M MiniSplit Mounting Stand-Dual Fan models-24" ❑ QSMS2402M 1/4 x 1/2 x 15'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MLS141212T-15 1/4 x 1/2 x 30'/ 1/2" Lineset (Twin-Tube Insulation) ❑ MLS141212T-30 1/4 x 1/2 x 50'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MLS141212T-50 1/4 x 1/2 x 65'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MLS141212T-65 1/4 x 1/2 x 100'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MLS141212T-100 Diamondback Linesets*1 3/8 x 5/8 x 10'/ 1/2" Lineset( )Twin-Tube Insulation ❑ MPLS385812T-10 3/8 x 5/8 x 15'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MPLS385812T-15 3/8 x 5/8 x 30'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MPLS385812T-30 3/8 x 5/8 x 50'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MPLS385812T-50 3/8 x 5/8 x 65'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MPLS385812T-65 3/8 x 5/8 x 100'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MPLS385812T-100 Linesets are indoor unit specific and will be listed in the IDU information -the Joint Pipe adaptors are used in this application Specifications are subject to change without notice. ©2018 Mitsubishi Electric US, Inc. DIMENSIONS: 1 Unit: inch (mm) 6-21/32" 19-11/16" 6-23/32" iv 2-9/16' 8-/32" 12-3/8" to V Inlet ` N M Air Inlet 3-e(1-5/16')Drain hole V Outlet 4.(13/32"x13/16")Oval Hole (Foundation Boll M8) Handle 33-1116" 1-3/16" ,may 7-7/8" 1-1/32" 13" 112" »frende�"g oo � 00 2-19/32" 0o m 00 U. 00 -- GAa UntlB LI0114"(b6.35)PARE oo LIQ GAa 31a"(eg.53)FLARE AS�UntlA 29/32" 11-25/32" 1.FREE SPACE E E E 3-15/16' or more p 0 8 3-15/16" or more 13-25/32' or more 2.SERVICE SPACE E E ® Grounding terminal ` "tlair 3-15/16'or more SERVICE SPACE 13-25/32' 0 13-25/32" o � q I:J�� MITSUBISHI alTk Conne— ELECTRIC COOLING & HEATING 1340 Satellite Boulevard, Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com AA IIs FORM#MXZ-2C20NA2-201805 Intertek Specifications are subject to change without notice. ©2018 Mitsubishi Electric US, Inc. RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:216 WESTJENSEN ST Project Description:2 ZONE DUCTLESS HEAT PUMP INSTALL Owner: IENNIFERTATON Address. 216 WJENSEN ST City. ARLINGTON State.WA Zip Code: 98223 Phone. 360-632-1247 Email:Taton_ranch@msn.com Applicant: CM HEATING - KAILANA MONIZ Address: 1415 BROADWAY City: EVERETT State.WA Zip Code: 98201 Phone. 425-259-0550 Email: KAILANA@CMHEALING.COM CONTRACTOR INFORMATION Contractor Name:CM HEALING Address: 1415 BROADWAY City. EVERETT State.WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration: 05-03-19 P hone: 425-259-0550 Email:KAILANA@CMH EATING.COM STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES ❑ Furnace (80+) Model # AFUE Heat Pump Model #MXZ2C20NA2 AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: [El Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: d5a513be"a92O�tlb81'b61e6' Date: 03/27/2019 Applicant Printed Name: KAILANA MONIZ I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 e Z� NOTICE 'P" TO PERMITEE AND/OR OWNER ❑ ;PARTIAL APPROVAL Cl CORRECTIONS REQUIRED ❑ DO NOT OCCUPY APPROVED PERMIT#: 9� �'-� LOT#; DATE:(o-I L4-1 L- JOBADDRESS: � , TYPE OF INSPECTION: 1-1 C\ ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK: MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION ` yQJ(1Y /Y alp ' � ' ' j- THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR " DATE /BUILDING DEPT. °PLANNING DEPT. CITY OF ARLINGTON '�" CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:216 W.Jensen St Permit#:2476 Parcel#:00560600000601 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:TATON TIMOTHY M/JENNIFER E Name:CM Heating Name:CM Heating Inc Address:PO BOX 2381 Address:]415 Broadway Address: 1415 Broadway City,State Zip:SNOHOMISH,WA 98291 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-0550 LIC: EXP: MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:CM Heating Inc Name: Address: 1415 Broadway Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-259-0550 Phone: LIC#:CMHEAMH977DN EXP: 03/15/2021 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: _ PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1I0/IRC110. SALES TAX NOTICE:Sales tax relating to constriction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. t l' c ✓ Signature Print Name Date cica ed y Date CONDITIONS 3" Concrete pad with seismic bracing attached. Provide electrical disconnect. Lines shall be insulated; use of adhesive tapes are prohibited. Adhere to approved appliance. Call for final inspection. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 3/28/2019 Heat Pump $25.00 3/28/2019 Mechanical Permit Base Fee $25.00 3/28/2019 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 2476 Permit Date: 03/28/19 Permit Type: RESIDENTIAL MECHANICAL Project Name: Taton Applicant Name: CM Heating Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett, WA 98201 Contact: Phone: 425-259-0550 Email: kailana@cmheating.com Scope of Work: 2 Zone ductless HP install Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 03/29/2019 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00560600000601 216 W JENSEN ST TATON TIMOTHY 111 Single Family M/JENNIFER E Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Plumbing CMHEAHL750LP ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION Construction CMHEAHL751 W ST STE 200 CONTRACTOR Contractor CM HEATING INC 425-259-0550 1500 INDUSTRY CONSTRUCTION UBI 605890285 ST STE 200 CONTRACTOR Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 06/18/2019 R04.PLUMBING 06/19/2019 BUILDING Completed GROUNDWORK Fees Fee Description Notes Amount Heat Pump/Heat Exchangers $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Total $75.00 Attached Letters Date Letter Description 03/28/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 03/28/2019 JAMES GARNER 74629385 iTransact CC $75.00 Outstanding Balance $0.00 Uploaded Files Date File Name 09/22/2021 9741633-2476 IC 6.19.2019 Final.pdf 03/28/2019 4695211-2476 Attachments.pdf 03/28/2019 4695212-2476 Application.pdf