HomeMy WebLinkAbout17011 59th Ave Ne_BLD2609_2026 GEOTEST 'IOakHarbor www.geotest-inc.com Concrete Inspection & Compressive Strength Test Report PROJECT: Royal Storage JOB#: 19-0608 ADDRESS: 17011 59th Avenue NE,Arlington, WA REPORT#: CB004 PERMIT M 2609 DATE: 11/21/2019 CLIENT: Baker&Sons Concrete Construction LLC PAGE#: 1 of 2 CONTRACTOR: Baker&Sons Concrete Construction L INSPECTOR: Tim Martin Placement Location: Building C-Caissons for 22 Canopy Columns at Eastern 100' of the Canopy Sample Location: 16 Eastern Most Caissons Field Data: Eq. No. Supplier Smokey Point Concrete/Skagit Read Slump, in.(C143) 2.25 19 Mix# 2253 Air Content, %(C231) NT Mix Description 5.5sk.7/8",w/MR Unit Weight,pcf(C138) NT Truck/Ticket# 6486/188871 Air/Mix Temp.,°F(C1064) 42/68 TM01 Strength Required 2500 psi at 28 days Field Cure Temperature,°F 48/71 TM01 Quantity Placed,cy 25 Cure Method-Initial/Final Container/Water Tank Time Batched 12:30 P.M Water Added on Job,gals 0 Time Sampled 1:15 P.M Water Requested by Laboratory Data: Lab Test Age Test Total Load Avg.D Area Compressive No. (Days) Date (Ibs) (in) (in 2) Strength (psi) Remarks 3880 6 11-27 53860 4.00 12.57 4280 TYPE 2: 3881 28 12-19 79080 4.00 12.57 6290 TYPE 2: 3882 28 12-19 74550 4.00 12.57 5930 TYPE 2: 3883 28 12-19 72910 4.00 12.57 5800 TYPE 2: 3884 Hold 00-00 0 0.00 0.00 0 Reinforcement Inspection Yes n/a: not applicable Specimen Size 4"X 8" Reinforcement Conforms Yes n/t: not tested Test Reference ASTM C31/C39/C1231 Comments: GeoTest was on site as requested to inspect the above items. The reinforcing steel cages and double 'C' 8" X 4" 12GA columns (with intermittent groove welds) were found to be in accordance with Detail 36 on Sheet SD2. COPIES:bakersonsconcretellc@gmail.com,chumphrey@safebuilt.com,gdavila@SmokeyPointConcrete.com, Reviewed by kolander@arlingtonwa.gov,Ipeterson@arlingtonwa.gov,troy@sharpdesignbuild.com This report shall not be reproduced except in full,without the written approval of GeoTest Services,Inc. The above test results relate to the sample(or location)tested. NOWT ,IO@kHarb r Bellingham I Arlington I Oak Harbor www.geotest-inc-com Concrete Inspection & Compressive Strength Test Report PROJECT: Royal Storage JOB M 19-0608 CLIENT: Baker&Sons Concrete Construction LLC REPORT#: CB004 CONTRACTOR: Baker&Sons Concrete Construction L PAGE M 2 of 2 log The water was vacuumed out of each eight-foot hole prior to placing the concrete. a ! !rt -• r " - 1. _ 51.5276 GEOT E S T 'I Oak Harbor Bellingham I Arlington I Oak Harbor www.geotest-inc.com Concrete Inspection & Compressive Strength Test Report PROJECT: Royal Storage JOB#: 19-0608 ADDRESS: 17011 59th Avenue NE,Arlington, WA REPORT#: CB006 PERMIT M 2609 DATE: 12/3/2019 CLIENT: Baker&Sons Concrete Construction LLC PAGE#: 1 of 2 CONTRACTOR: Baker&Sons Concrete Construction L INSPECTOR: Joel Morder Placement Location: Building C Sono-Tubes Sample Location: First Load, Middle of the Batch Field Data: Eq. No. Supplier Smokey Point Concrete/Skagit Read Slump, in.(C143) 5.50 15 Mix# 01550P Air Content, %(C231) NT Mix Description 5.5 Sack,7/8"Agg Unit Weight,pcf(C138) NT Truck/Ticket# 78732/189743 Air/Mix Temp.,°F(C1064) 50/57 JM5 Strength Required 2500 psi at 28 days Field Cure Temperature,°F NT Quantity Placed,cy 70 Cure Method-Initial/Final Container/Water Tank Time Batched 10:01 AM Water Added on Job,gals 10 Time Sampled 10:50 AM Water Requested by Contractor Laboratory Data: Lab Test Age Test Total Load Avg.D Area Compressive No. (Days) Date (Ibs) (in) (in 2) Strength (psi) Remarks 4272 7 12-10 58320 4.00 12.57 4640 TYPE 2: 4273 28 12-31 68250 4.00 12.57 5430 TYPE 2: 4274 28 12-31 71430 4.00 12.57 5680 TYPE 2: 4275 28 12-31 74780 4.00 12.57 5950 TYPE 2: 4276 Hold 00-00 0 0.00 0.00 0 Reinforcement Inspection NT n/a: not applicable Specimen Size 4"X 8" Reinforcement Conforms NT n/t: not tested Test Reference ASTM C31/C39/C1231 Comments: GeoTest on site for inspection of concrete placed for the sono-tubes in the zone pictured below. Concrete was placed by truck chute and consolidated through mechanical vibration. All elements inspected were in conformance with approved plans and drawings. COPIES:bakersonsconcretellc@gmail.com,chumphrey@safebuilt.com,gdavila@SmokeyPointConcrete.com, Reviewed by kolander@arlingtonwa.gov,Ipeterson@arlingtonwa.gov,troy@sharpdesignbuild.com This report shall not be reproduced except in full,without the written approval of GeoTest Services,Inc. The above test results relate to the sample(or location)tested. 51.5276 GEOT E S T I O' @k Harbor Bellingham I Arlington Oak Harborr www.geotest-inc-com Concrete Inspection & Compressive Strength Test Report PROJECT: Royal Storage JOB M 19-0608 CLIENT: Baker&Sons Concrete Construction LLC REPORT#: CB006 CONTRACTOR: Baker&Sons Concrete Construction L PAGE#: 2 of 2 Concrete Placement in S ;- Progress Area of Concrete Placement 51.5276 GEOT E S T 'I Oak Harbor Bellingham I Arlington I Oak Harbor www.geotest-inc.com Concrete Inspection & Compressive Strength Test Report PROJECT: Royal Storage JOB#: 19-0608 ADDRESS: 17011 59th Avenue NE,Arlington, WA REPORT#: CB006 PERMIT M 2609 DATE: 12/3/2019 CLIENT: Baker&Sons Concrete Construction LLC PAGE#: 1 of 2 CONTRACTOR: Baker&Sons Concrete Construction L INSPECTOR: Joel Morder Placement Location: Building C Sono-Tubes Sample Location: First Load, Middle of the Batch Field Data: Eq. No. Supplier Smokey Point Concrete/Skagit Read Slump, in.(C143) 5.50 15 Mix# 01550P Air Content, %(C231) NT Mix Description 5.5 Sack,7/8"Agg Unit Weight,pcf(C138) NT Truck/Ticket# 78732/189743 Air/Mix Temp.,°F(C1064) 50/57 JM5 Strength Required 2500 psi at 28 days Field Cure Temperature,°F NT Quantity Placed,cy 70 Cure Method-Initial/Final Container/Water Tank Time Batched 10:01 AM Water Added on Job,gals 10 Time Sampled 10:50 AM Water Requested by Contractor Laboratory Data: Lab Test Age Test Total Load Avg.D Area Compressive No. (Days) Date (Ibs) (in) (in 2) Strength (psi) Remarks 4272 7 12-10 58320 4.00 12.57 4640 TYPE 2: 4273 28 12-31 68250 4.00 12.57 5430 TYPE 2: 4274 28 12-31 71430 4.00 12.57 5680 TYPE 2: 4275 28 12-31 74780 4.00 12.57 5950 TYPE 2: 4276 Hold 00-00 0 0.00 0.00 0 Reinforcement Inspection NT n/a: not applicable Specimen Size 4"X 8" Reinforcement Conforms NT n/t: not tested Test Reference ASTM C31/C39/C1231 Comments: GeoTest on site for inspection of concrete placed for the sono-tubes in the zone pictured below. Concrete was placed by truck chute and consolidated through mechanical vibration. All elements inspected were in conformance with approved plans and drawings. COPIES:bakersonsconcretellc@gmail.com,chumphrey@safebuilt.com,gdavila@SmokeyPointConcrete.com, Reviewed by kolander@arlingtonwa.gov,Ipeterson@arlingtonwa.gov,troy@sharpdesignbuild.com This report shall not be reproduced except in full,without the written approval of GeoTest Services,Inc. The above test results relate to the sample(or location)tested. 51.5276 GEOT E S T I O' @k Harbor Bellingham I Arlington Oak Harborr www.geotest-inc-com Concrete Inspection & Compressive Strength Test Report PROJECT: Royal Storage JOB M 19-0608 CLIENT: Baker&Sons Concrete Construction LLC REPORT#: CB006 CONTRACTOR: Baker&Sons Concrete Construction L PAGE#: 2 of 2 Concrete Placement in S ;- Progress Area of Concrete Placement 51.5276 GEOT E S T 'I Oak Harbor Bellingham I Arlington I Oak Harbor www.geotest-inc.com Concrete Inspection & Compressive Strength Test Report PROJECT: Royal Storage JOB#: 19-0608 ADDRESS: 17011 59th Avenue NE,Arlington, WA REPORT#: CB006 PERMIT M 2609 DATE: 12/3/2019 CLIENT: Baker&Sons Concrete Construction LLC PAGE#: 1 of 2 CONTRACTOR: Baker&Sons Concrete Construction L INSPECTOR: Joel Morder Placement Location: Building C Sono-Tubes Sample Location: First Load, Middle of the Batch Field Data: Eq. No. Supplier Smokey Point Concrete/Skagit Read Slump, in.(C143) 5.50 15 Mix# 01550P Air Content, %(C231) NT Mix Description 5.5 Sack,7/8"Agg Unit Weight,pcf(C138) NT Truck/Ticket# 78732/189743 Air/Mix Temp.,°F(C1064) 50/57 JM5 Strength Required 2500 psi at 28 days Field Cure Temperature,°F NT Quantity Placed,cy 70 Cure Method-Initial/Final Container/Water Tank Time Batched 10:01 AM Water Added on Job,gals 10 Time Sampled 10:50 AM Water Requested by Contractor Laboratory Data: Lab Test Age Test Total Load Avg.D Area Compressive No. (Days) Date (Ibs) (in) (in 2) Strength (psi) Remarks 4272 7 12-10 58320 4.00 12.57 4640 TYPE 2: 4273 28 12-31 68250 4.00 12.57 5430 TYPE 2: 4274 28 12-31 71430 4.00 12.57 5680 TYPE 2: 4275 28 12-31 74780 4.00 12.57 5950 TYPE 2: 4276 Hold 00-00 0 0.00 0.00 0 Reinforcement Inspection NT n/a: not applicable Specimen Size 4"X 8" Reinforcement Conforms NT n/t: not tested Test Reference ASTM C31/C39/C1231 Comments: GeoTest on site for inspection of concrete placed for the sono-tubes in the zone pictured below. Concrete was placed by truck chute and consolidated through mechanical vibration. All elements inspected were in conformance with approved plans and drawings. COPIES:bakersonsconcretellc@gmail.com,chumphrey@safebuilt.com,gdavila@SmokeyPointConcrete.com, Reviewed by kolander@arlingtonwa.gov,Ipeterson@arlingtonwa.gov,troy@sharpdesignbuild.com This report shall not be reproduced except in full,without the written approval of GeoTest Services,Inc. The above test results relate to the sample(or location)tested. 51.5276 GEOT E S T I O' @k Harbor Bellingham I Arlington Oak Harborr www.geotest-inc-com Concrete Inspection & Compressive Strength Test Report PROJECT: Royal Storage JOB M 19-0608 CLIENT: Baker&Sons Concrete Construction LLC REPORT#: CB006 CONTRACTOR: Baker&Sons Concrete Construction L PAGE#: 2 of 2 Concrete Placement in S ;- Progress Area of Concrete Placement CITY OF ARL"-NGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 12 PHONE; (360) 403-3551 BUMI)INO PERMIT Address:17011 59th Avenue NE,Bldg C Permit#:2609 Parcel#:31052700100800 Valuation:2153322.00 OWNER APPLICANT CONTRACTOR Name:PREMIER PACIFIC PROPERTIES LLC Name:Sharp Design&Build,Inc. Name:Sharp Design&Build,LLC Address: 13600 44TH ST NE Address:13600 44th Street NE Address: 13600 44th Street NE City,State Zip:LAKE STEVENS,WA 98258 City,State Zip:Lake Stevens,WA 98258 City,State Zip:Lake Stevens,WA 98258 Phone: Phone:425-760-8689 Phone:425-760-8689 LIC:SHARPDB852KK EXP:05/30/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial New CODE YEAR: 2015 STORIES: I CONST.TYPE: II-B DWELLING UNITS: O OCC GROUP: S-1 BUILDINGS: I OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and rtomtC .r ington#3 I01. Signature Print Name Date Re ea By ate CONDITIONS Approved job copy shall be on site for inspections. Adhere to approved plans. Call for inspections. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERIVEF>f'b'EES Date Description Fee Amount 7/11/2019 Building Permit Fee $14,501.98 7/11/2019 Building Plan Review Fee $9,426.29 7/11/2019 Processing/Technology Fee $25.00 7/11/2019 State Surcharge-Commercial $25.00 Total Due: $23,978.27 Total Payment: $0.00 Balance Due: $23,978.27 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon � ' 1 Permit Information Date 6/12/2019 Permit Number 2609 Project Name Royal Storage Applicant Name Sharp Design&Build, Inc. Applicant Address 13600 44th Street NE City,State,Zip Lake Stevens,WA 98258 Contact Troy Van Kopp Phone 425-760-8689 Email troy@sharpdesignbuild.com Permit Type Commercial New Site Address 17011 59th Avenue NE,Bldg C Valuation 2153322.00 Status Ready to Issue Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use Storage and Office MIC/Opportunity Zone MIC Assigned To Kristin Foster Property Owner Parcel Address Legal Owner Phone Zoning 17011 Section 27 Township 31 Range 05 Quarter NE1/4-PAR 2 OF BLA REC AFN PREMIER 910 31052700100800 59th 200108315002 EXC TH PTN OF SD PAR 2 LY N OF S LN OF PAR 1 OF SD PACIFIC Undeveloped Avenue BLA PROJ ELY TO E LN OF SD PAR 2&EXC RIDS-AKA PAR 2 OF CITYOF PROPERTIES (Vacant) NE ARL BLA NO Z-06-015-BLA REC AFN 200606055267 ILLC I Land Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# Sharp Design&Build, LLC [rroy Van Ko 25-760-8689 kroyasharpdesignbuild.com ICONTRACTOR Fees Fee Description Notes Amount Building Permit Fee 322.10.00.00 $14,501.98 Buildinq Plan Review Fee 345.83.00.00 $9,426.29 Processin /Technolo Fee 341.43.00.02 $25.00 State Surcharge-Commercial 386.00.01.00 $25.00 Total $23 978.27 Uploaded Files Upload File Date File Uploaded By 77=7 i 7/11/2019 8:40:39 AM 12609 Applicatior (Post "rislin �( f � , 41 .y Off, COMMERCIAL APPLICATION Iri1r.10 PERMIT SUBMITTAL Department of Community& Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360)403-3551 The following minimum Information Is required for your Commercial/Multi-Family Building Permit Application. Mark each box to designate that the information has been provided. Please submit this checklist as part of your submittal documents. Incomplete applications will delay the review. I� One (1) City of Arlington CommerciaUMulti-Family Permit Application (One (1) permit application per building or structure is required) El ne (1) City of Arlington Comm erciaUMulti-Family Submittal Requirements Form Q-_ Two (2)Architectural Drawings 93--- Two (2) Structural Drawings Q� Two(2) Structural Calculations One (1) Project Specification Manuals(if applicable) One (1) NREC Code Compliance Forms ❑ One(1) Special Inspection Requirements Forms ©� One (1) Occupant's Statement of Intended Use Form Drawings shall be BOUND SEPARATELY BY TYPE, architectural, structural and landscape, and then ROLLED TOGETHER IN COMPLETE SETS An intake appointment Is required for all new Commercial or Multi-Family Building Permit Applications. To schedule an appointment please contact the City of Arlington Permit Center at(360)403 3551 or by email to cedC@arlingtonwa.gov. I acknowledge that all Items designated above are included as part of this application. REV 2015 Page 1 of 9 COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community& Economic Development City of Arlington• 18204 59th Ave NE•Arlington,WA 98223• Phone(360) 403-3551 A. FEES DUE AT TIME OF PERMIT ISSUANCE B. CODES The City of Arlington currently enforces the following: International Codes 1. 2015 International Building Code(IBC) 2. 2015 International Residential Code(IRC) 3. 2015 International Mechanical Cade(IMC) 4. 2015 International Fuel Gas Code(IFGC) 5. 2015 International Fire Code(IFC) 6. 2015 International Plumbing Code(IPC) 7. 2015 International Property Maintenance Code(IPMC) 8. 2015 International Existing Property Code(IEBC) 9. 2015 Washington State Energy Code(WESC) 10_ 2009 Accessible&Usable Buildings and Facilities(ICC/ANSI 1417.1) WaghinatQn State Amendments t. WAC 51-50 Washington State Building Code 2. WAC 51.51 Washington State Residential Code 3. WAC 51-52 Washington State Mechanical Code 4. WAC 51-54 Washington State Fire Code 5. WAC 51-56&51-57 Washington State Plumbing Code and Standards 6. WAC 51-11 Washington State Energy Code 7. WAC 296-46B Electrical Safety Standards,Administration, and Installation C. CITY OF ARLINGTON DESIGN REQUIREMENTS Design Wind Speed: 85 miles per hour(Exposure C) Ground Snow Load: 25 pounds per square foot Seismic Zone: D2 Rainfall: 2 inches per hour for roof drainage design. Frost Line Depth: 12 inches Soil Bearing Capacity: 1,500 psf unless a Geo-Technical Report is provided.(IBC;Table 1804.2&I RC R401.4.1) D. PLANS AND DRAWINGS Submit two(2)complete sets of drawings and plans.Drawings and plans must be submitted on minimum 18"X 24", or maximum 30"X 42"paper All sheets are to be the same size and sequentially labeled. Plans are required to be clearly legible,with scaled dimensions, in indelible ink,blue line,or other professional media.Plans will not be accepted that are marked preliminary or not for construction,that have red lines,cut and paste details or those that have been altered after the design professional has signed the plans. Please Note:A separate submittal of plans is required for each building or structure. REV 2015 Page 2 of 9 v��f � - COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community& Economic Development City of Arlington• 18204 59th Ave NE• Arlington, WA 98223• Phone(360)403-3551 DETAILED SUBMITTAL REQUIREMENTS Mark each box to designate that the information has been provided. Please submit this checklist as part of your submittal documents A. ❑ SITE PLAN—REQUIRED WITH ALL SUBMITTALS (May be included as part of the Architectural Drawing cover Sheet) 1. Drawing shall be prepared at scale not to exceed 1"=20 feet. 2. Show building outline and all exterior improvements. 3. Provide property legal description and show property lines. 4. Provide dimensions from the property lines to a minimum of two building corners(or two identifiable locations for irregular plan shapes). 5. Show building setbacks,easements and street access locations. 6. Indicate North direction. 7. Indicate finish floor elevation for the first level. 8. Provide topographical map of the existing grades and the proposed finished grades with maximum five feet elevation contour lines. 9. Show the location of all existing underground utilities, including water,sewer,gas and electrical. 10. Flood hazard areas,floodways,and design flood elevations as applicable. B. ❑ ARCHITECTURAL DRAWINGS 1. ❑ Cover Sheet a) Building Information 1. Specify model code information. 2. Construction Type. 3. Number of stories and total height in feet. 4. Building square footage(per floor and total) 5. IBC Occupancy Type(show all types by floor and total). 6. Mixed-use ratio(if applicable) 7. Occupant load calculation(show by occupancy type and total) 8. List work to be performed under this permit b) Design Team Information 1. Design Professional in Responsible Charge 2. Architects 3, Structural Engineers 4. Owner 5. Developer 6. Any other Design Team Members 2. ❑ Floor Plan a) Plan view 1/8"minimum scale.Details a minimum %.-inch scale. b) Plans must show the entire tenant space. c) Specify the use of each room/area. d) Provide an occupant load calculation on the floor plan.(on every floor,in all rooms and spaces) e) Show ALL exits on the plans;include new,existing or eliminated. f) Show Barrier-Free information on the drawings. g) Show the location of all permanent rooms,walls and shafts. h) Note the uses in the adjacent tenant spaces,if applicable. i) Provide a door and door hardware schedule. REV 2015 Page 3 of 9 tu1�1 O� COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community& Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 j) Show the location of all new walls,doors,windows, etc. k) Provide details and assembly numbers for any fire resistive assemblies. 1) Indicate on the plans all rated walls,doors,windows and penetrations. m) Provide a legend that distinguishes existing walls,walls to be removed and new walls. 3. ❑ Reflected Ceiling Plan a) Plan view 1/8"minimum scale, Details a minimum %,-inch scale. b) Provide ceiling construction details. c) Provide suspended ceiling details complying with IBC 803.9.1.1. Show seismic bracing details. d) Show the location of all emergency lighting and exit signage. e) Detail the seismic bracing of the fixtures. f) Include alighting fixture schedule. 4. ❑ Framing Plan a) Specify the size, spacing,span and wood species or metal gage for all stud walls, b) Indicate all wall, beam and floor connections. c) Detail the seismic bracing for all walls. d) Include a stair section showing rise,run,landings,headroom,handrail and guardrail dimensions. 5 Li Storage Racks(if applicable) a) Structural calculations are required for seismic bracing of storage racks eight feet or greater in height. b) Eight foot or loco,chow a poeitive connection to floor or walls. NOTE:High pile storage shall meet the requirements of current International Building and Fire Codes, C. ❑ SPECIAL INSPECTION 1. Where special inspection is required by IBC 1704,the registered design professional in responsible charge shall prepare a special inspection program that will be submitted to the City of Arlington and approved prior to issuance of the building permit to comply with IBC 106.1. D. ❑ WASHINGTON STATE ENERGY CODE 1.One(1)completed Washington State Non-Residential Energy Code Envelope Summary forms. E. OCCUPANT'S STATEMENT OF INTENDED USE 1. The Occupant's Statement of Intended Use form shall be completely filled out and may require the submittal of a Hazardous Materials inventory Statement(HMIS).Contact the Arlington REV 2015 Page 4 of 9 COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community& Economic Development City of Arlington• 18204 59th Ave NE- Arlington,WA 98223• Phone(360)403-3551 The building permit does not include any mechanical, electrical, plumbing or fire sprinkler/alarm work.These permits are issued separately.Mechanical,electrical, plumbing, or fire sprinkler/alarm permits require a separate permit application and may also require separate plan review. Please note that any tenant improvement work in a space that involves food handling or preparation requires Snohomish County Health District approval before the permit can be issued. You must provide the Permit Center a copy of the approval letter or the approved plans. Contact the Snohomish County Health District at(425) 339-5250 with any questions or for more information. An intake appointment is required for all large Tenant Improvement Building Permit Applications. To determine it your project requires an intake appointment,to schedule an appointment or to ensure that you have the most current information,please contact the City of Arlington Permit Center at(360)403-3551 or by email to ced@arlingtonwa.gov. Incomplete applications will not be accepted. I acknowledge that all items designated as submittal requirements must accompany my Building Permit Application to be considered a complete submittal. REV 2015 Page 5 of 9 G1T x COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community& Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION TO BE USED FOR NEW COMMERCIAL STRUCTURES AND RESIDENTIAL DWELLINGS NOT REGULATED UNDER THE IRC. THIS APPLICATION MUST BE ACCOMPANIED BYA COMMERCIAL APPLICATION SUBMITTAL CHECKLIST AND AN OCCUPANT'S STATEMENT OF INTENDED USE. Name of Project:ROYAL STORAGE Valuation: $4 MIL Project Address: 17011 59TH AVE NE, ARLINGTON, WA 98223 Parcel ID#: 31052700100800 Legal Description NE 1/4 27-31-05 Owner: ROYAL STORAGE, LLC Phone Number: 425-760-8689 Address: 13600 44TH ST NE City: LAKE STEVENS State:WA Zip Code:98258 Engineer:PACIFIC SURVEYING & ENGINEERING Phone Number: 360-671-7387 Cell Phone: 360-815-3885 E-mail: DGALBRAITH(c)PSESURVEY.COM 909 SQUALICUM WAY STE 111 BELLINGHAM Wq 9B225 Address: City: State: Zip Code: General Contractor:SHARP DESIGN & BUILD, LLC Phone Number:425-760-8689 Cell Phone: 425-760-8689 E-mail: TROY@SHARPDESIGNBUILD.COM Address 13600 44TH ST NE City:LAKE STEVENS State: WA Zip Code: 98258 Contractor's License Number:S HARPDB852KK Expiration:05-30-2021 Contact Person: TROY VAN KOPP Phone Number: 425-760-8689 Cell Phone: 425-760-8689 E-mail:TROY@SHARPDESIGNBUILD.COM Address: 13600 44TH ST NE City:LAKE STEVENS State: \AIA Zip Code: 98258 Proposed Scope of Work:N EW S ELF-STORAGE FACILITY REV 2015 Page 6 of 9 COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community& Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360)403-3551 Project Name/Tenant ROYAL STORAGE Site Address17011 59TH AVE NE, ARLINGTON, WA 98223 Bldg/Unit/Suite IBC Construction Type II-B IBC Occupancy Type B.S1.0 Description of Use SELF-STORAGE Building Square Footage 73,620 including 30,600 Canopy Number of Stories Office 2; All others 1 Square Footage Per Floor First Floor: 41,900, Second Floor: 1,120, Canopy: 30,600 Will there be any Installation,modification or removal of the following?(Check all that apply) ❑ Automatic fire extinguishing systems ❑ Compressed gas systems ❑ Fire alarm and detection systems ❑ Fire pumps ❑ Flammable and combustible liquids(tanks,piping etc. .) ❑ Hazardous materials ❑ High plied/rack storage ❑ Industrial ovens/furnace la Private fire hydrants ❑ Spraying or dipping operations ❑ Standpipe systems ❑ Temporary membrane structure,tents(>200sq ft)or canopies(>400 sq ft) Provide delads nn_lny_gf the above checkec]items- Installation,changes,modifications or removal of any of the above may require additional submittals, Information, or permits during the plan review or construction process. Statement of Special Inspection REV 2015 Page 7 of 9 COMMERCIAL APPLICATION PERMIT SUBMITTAL ,elf G O Department of Community& Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360)403-3551 ROYAL STORAGE Name of Project: Protect Address: 17011 59TH AVE NE, ARLINGTON, WA 98223 Special Inspection Firm: Address: Contact Person: Phone: Email: Special Inspection Firm Special Inspectors: The Special inspection Firm of ._ will perform special inspection for the following types of work(separate forms must be submitted if more than one firm is to be employed). (,e) Reinforced Concrete ( 1 Boltino in Concrete ( ) Pre-stressed Concrete ( ) Shotcrete V) Structural Masonry V) Structural Steel and Welding ( ) High-Strength Bolting ( ) Spray-Applied Fireproofing ( ) Smoke-Control Systems ( ) Other Specify All individual inspectors to be employed on this project will be WABO certified for the type of inspection they are to perform. 11 inspection is for work that is not covered by the WABO categories,a detailed resume of the inspector and firm must be submitted.The resume must show the inspector and firm are qualified to perform the work and testing required by the project design and specifications. The work shall be inspected for conformance with the plans and specifications approved by the City. Revisions and addenda sheets will not be used for inspection unless approved by the City.The special inspector shall report to the City revisions that are not approved. A daily record will be maintained on site itemizing the inspections performed,for the review of all parties.Any nonconforming items shall be brought to the immediate attention of the contractor for resolution. A weekly shall be submitted to the City;detailing the inspections and testing performed, listing any nonconforming items and resolution of nonconforming items.Unresolved nonconforming items will be detailed on a discrepancy report and presented to the building department. A final report shall be submitted to the Building Division prior to the Certificate of Occupancy being issued.This report will indicate that inspection and testing was completed in conformance with the approved plans,specifications and approved revisions and addenda. Any unresolved discrepancies must be detailed in the final report. The special inspector and speclal inspection firm serve in the role as"deputy"City of Arlington inspectors and as such are responsible to the City of Arlington Building Division in the performance of the required work. Contractor: The contractor shall provide the special inspector or agency adequate notification of work requiring inspection. The City approved plans and specifications must be made available, at the job site for the use of the special inspector and the City Inspector.The contractor shall maintain all daily inspections reports,on site,for review. REV 2015 Page 8 of 9 Y 41, COMMERCIAL APPLICATION PERMIT SUBMITTAL LjNC1 Department of Community & Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 96223 • Phone(360)403-3551 The special inspection functions are considered to be in addition to the normal inspections performed by the City and the contractor is responsible for contacting the City to schedule regular inspections.No concrete shall be poured or other work covered until approved by the City Inspector. Building Division: The Building Division shall review any revisions and addenda.Approved copies will be given to the contractor to maintain as part of the approved plan set. The City Inspector will monitor the special inspection functions for compliance with the agreement and the approved plans. The City Inspector shall be responsible for approving various stages of construction to be covered and work to proceed. Design Professionals: The architect and engineer will clearly indicate on the plans and specifications for the specific types of special inspection required, and shall include a schedule for inspection and testing. The architect and engineer will coordinate their revisions and addenda process in such a way as to insure all required City approvals are obtained,prior to work shown on the revisions being performed. Owner: The project owner, or the architect or engineer acting as the owners agent, shall employ the special inspector or agency. ENFORCEMENT: A failure of the special inspector or firm to perform in keeping the requirements of the IBC,the approved plans and this document may void this agreement and the Building Officials approval of the special inspector.In such case a new special inspector and/or firm would need to be proposed for approval.A failure of the design and/or construction parties to perform in accordance with this agreement may result in a STOP WORK notice being posted on the project,until nonconforming items have been resolved. ACKNOWLEDGEMENTS I have read and agree to comply with the terms and conditions of this agreement. Owner:TROY VAN KOPP Date: I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington. Applicants Signature TROY VAN KOPP Print Applicants Name Date FOR STAFF USE ONLY ROr✓2lVP.d Permit# Accepted By Amount Received Receipt# ,l L ANt REV 2015 Page 9 of 9 K .. 1 I I *�.&_ City of Arlington 112vul n OO IF 4 D e M@Nj`4`�d Public Works 238 N. Olympic•Arlington, WA 98223 DATE / G.. ,os NO. ❑Administration ❑Maintenance & Operations ATTENTION ❑Engineering ❑Utilities TO RE: Ell WE ARE SENDING YOU ❑ Attached ❑ Under separate cover via the following items: ❑ Shop drawings ❑ Prints ❑ Plans ❑ Samples ❑ Specifications ❑ Copy of letter ❑ Change order ❑ COPIES DATE NO. DESCRIPTION I t C THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ Approved as submitted ❑ Resubmit copies for approval ❑ For your use ❑ Approved as noted ❑ Submit copies for distribution ❑ As requested ❑ Returned for corrections ❑ Return corrected prints ❑ For review and comment ❑El FORBIDS FOR BIDS DUE 20 ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS rQ COPY Toll Af Ir SIGNED: If enclosures are not as noted, kindly notify us at once. °� City of Arlington [LIETTIgn OO 7 cffunOOGV]�44Ca� • Public Works .7 \G,�0 238 N. Olympic *Arlington, WA 98223 DATE roe ❑Administration ❑Maintenance & Operations ATTENTION TO ❑Engineering ❑Utilities WE ARE SENDING YOU ❑ Attached ❑ Under separate cover via the following items: > ❑ Shop drawings ❑ Prints Plans ❑ Samplesn Specifications ❑ Copy of letter ❑ Change order ❑ COPIES DATE NO. DESCRIPTION Am) THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ Approved as submitted ❑ Resubmit copies for approval ❑ For your use ❑ Approved as noted ❑ Submit copies for distribution ❑ As requested ❑ Returned for corrections ❑ Return corrected prints ' 'For review and comment ❑ FORBIDS DUE 20 ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS COPY TO SIGNED: If enclosures are not as noted, kindly notify us at once. 08T" 0� City of Arlington HEVVI n OO P • Development Services ING�oz 238 N. Olympic • Arlington, WA 98223 DATE I JOB NO. ❑Administration ❑Buildin ❑E ineerin J ` g n g g ATTENTION ❑Planning ❑Utilities TO ,_: RE WE ARE SENDING YOU ❑ Attached ❑ Under separate cover via the following items: ❑ Shop drawings ❑ Prints ❑ Plans ❑ Samples ❑ Specifications ❑ Copy of letter ❑ Change order ❑ COPIES DATE NO. DESCRIPTION THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ Approved as submitted ❑ Resubmit copies for approval ❑ For your use ❑ Approved as noted ❑ Submit copies for distribution ❑ As requested ❑ Returned for corrections ❑ Return corrected prints ❑ For review and comment ❑ ❑ FORBIDS DUE 19 ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS i COPY TO SIGNED: f tt anctosuras ara not as noted_ktndty notify us at once. it Labor Safety&Health 0- Claims&Insurance 1n- Workplace Rig ..- Washington State Department of Labor & Industries Sharp Design& Build L!C Owner or tradesperson THOMAS,LISA MARIE 13600 44TH ST NE Principals LAKE STEVENS,WA 98258 THOMAS,LISA MARIE,PARTNER/MEMBER 425-377-9130 SNOHOMISH County THOMAS,DAVID WILLIAM,PARTNER/MEMBER VAN KOPP,TROY EUGENE,PARTNER/MEMBER ■ Thomas,Edmund Mark,MANAGER (End:05/17/2017) WA UBI No. Business type 603 408 597 Limited Liability Company Certifications&Endorsements License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. SHARPDB852KK Effective—expiration 05/12/2015—05/30/2021 Bond Cincinnati Ins Co $12,000.00 Bond account no. B1220327 Received by L&I Effective date 05/12/2015 04/28/2015 Expiration date Until Canceled Insurance Travelers Property Cas Co of A $1,000,000.00 Policy no. DT-CO-3655R040-IND-1 Received by L&I Effective date 05/13/2019 07/07/2018 Expiration date 07/07/2020 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or svings No lawsuits against the bondo.r savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Public Works Requirements Workplace safety and health �Wuhirtglvn� ;� I y � �.. r w a O a rt 1 O M OD • tin � rny � 0 cn Covr� p�, Ci7 to 41 G. N c o ycoo tz�7 rr o" � N n Zc z ~ r00 CD > � oz n � W !' n V n p ~ Q n V) > CD � z d � �"'J o r� Ln tz� cm co ° CA CD oN N •, n z CD ... o x r � � a z Z z CD C n (D � o Ln K o H COMMERCIAL APPLICATION ��l�Nc,10 PERMIT SUBMITTAL Department of Community& Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223- Phone(360)403-3551 The following minimum information is required for your Commercial/Multi-Family Building Permit Application. Mark each box to designate that the Information has been provided. Please submit this checklist as part of your submittal documents. Incomplete applications will delay the review. 2/ One (1) City of Arlington CommerciaVMulti-Family Permit Application (One (1) permit application per building or structure is required) T)ne (1) City of Arlington Comm ercial/MuIti-Family Submittal Requirements Form Two (2)Architectural Drawings ®� Two (2) Structural Drawings ®� Two (2) Structural Calculations One (1) Project Specification Manuals(if applicable) LrJ One (1) NREC Code Compliance Forms ❑ One (1) Special Inspection Requirements Forms ©� One (1) Occupant's Statement of Intended Use Form Drawings shall be BOUND SEPARATELY BY TYPE, architectural, structural and landscape, and then ROLLED TOGETHER IN COMPLETE SETS An intake appointment is required for all new Commercial or Multi-Family Building Permit Applications. To schedule an appointment please contact the City of Arlington Permit Center at(360)403 3551 or by email to cedParlingtonwa.gov. I acknowledge that all Items designated above are included as part of this application. REV 2015 Page 1 of 9 COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community & Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 A. FEES DUE AT TIME OF PERMIT ISSUANCE B. CODES The City of Arlington currently enforces the following: International Codes 1. 2015 International Building Code(IBC) 2. 2015 International Residential Code(IRC) 3. 2015 International Mechanical Code(IMC) 4. 2015 International Fuel Gas Code(IFGC) 5. 2015 International Fire Code(IFC) 6. 2015 International Plumbing Code(IPC) 7. 2015 International Property Maintenance Code(IPMC) 8. 2015 International Existing Property Code(IEBC) 9. 2015 Washington State Energy Code(WESC) 10. 2009 Accessible&Usable Buildings and Facilities(ICC/ANSI 1417.1) Washington State Amendments 1. WAC 51-50 Washington State Building Code 2. WAC 51.51 Washington State Residential Code 3. WAC 51-52 Washington State Mechanical Code 4. WAC 51-54 Washington State Fire Code 5. WAC 51-56&51-57 Washington State Plumbing Code and Standards 6. WAC 51-11 Washington State Energy Code 7. WAC 296-46B Electrical Safety Standards,Administration, and Installation C. CITY OF ARLINGTON DESIGN REQUIREMENTS Design Wind Speed: 85 miles per hour(Exposure C) Ground Snow Load: 25 pounds per square foot Seismic Zone: D2 Rainfall: 2 inches per hour for roof drainage design. Frost Line Depth: 12 inches Soil Bearing Capacity: 1,500 psf unless a Geo-Technical Report is provided.(IBC Table 1804.2&IRC R401.4.1) D. PLANS AND DRAWINGS Submit two(2)complete sets of drawings and plans.Drawings and plans must be submitted on minimum 18"X 24", or maximum 30"X 42"paper.All sheets are to be the same size and sequentially labeled. Plans are required to be clearly legible,with scaled dimensions, in indelible ink, blue line,or other professional media.Plans will not be accepted that are marked preliminary or not for construction,that have red lines,cut and paste details or those that have been altered after the design professional has signed the plans. Please Note:A separate submittal of plans is required for each building or structure. REV 2015 Page 2 of 9 COMMERCIAL APPLICATION �N��o PERMIT SUBMITTAL Department of Community & Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223 • Phone(360)403-3551 DETAILED SUBMITTAL REQUIREMENTS Mark each box to designate that the information has been provided. Please submit this checklist as part of your submittal documents A. ❑ SITE PLAN-REQUIRED WITH ALL SUBMITTALS (May be included as part of the Architectural Drawing cover Sheet) 1. Drawing shall be prepared at scale not to exceed 1"=20 feet. 2. Show building outline and all exterior improvements. 3. Provide property legal description and show property lines. 4. Provide dimensions from the property lines to a minimum of two building corners(or two identifiable locations for irregular plan shapes). 5. Show building setbacks, easements and street access locations. 6. Indicate North direction. 7. Indicate finish floor elevation for the first level. 8. Provide topographical map of the existing grades and the proposed finished grades with maximum five feet elevation contour lines. 9. Show the location of all existing underground utilities, including water,sewer,gas and electrical. 10. Flood hazard areas,floodways,and design flood elevations as applicable. B. ❑ ARCHITECTURAL DRAWINGS 1. ❑ Cover Sheet a) Building Information 1. Specify model code information. 2. Construction Type. 3. Number of stories and total height in feet. 4. Building square footage(per floor and total) 5. IBC Occupancy Type(show all types by floor and total). 6. Mixed-use ratio(if applicable) 7. Occupant load calculation(show by occupancy type and total) 8. List work to be performed under this permit b) Design Team Information 1. Design Professional in Responsible Charge 2. Architects 3. Structural Engineers 4. Owner 5. Developer 6. Any other Design Team Members 2. ❑ Floor Plan a) Plan view 1/8"minimum scale.Details a minimum %.-inch scale. b) Plans must show the entire tenant space. c) Specify the use of each room/area. d) Provide an occupant load calculation on the floor plan.(on every floor,in all rooms and spaces) e) Show ALL exits on the plans;include new,existing or eliminated. f) Show Barrier-Free information on the drawings. g) Show the location of all permanent rooms,walls and shafts. h) Note the uses in the adjacent tenant spaces,if applicable. i) Provide a door and door hardware schedule. REV 2015 Page 3 of 9 o COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community & Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 j) Show the location of all new walls,doors,windows, etc. k) Provide details and assembly numbers for any fire resistive assemblies. 1) Indicate on the plans all rated walls,doors,windows and penetrations. m) Provide a legend that distinguishes existing walls,walls to be removed and new walls. 3. ❑ Reflected Ceiling Plan a) Plan view 1/8"minimum scale. Details a minimum Yvinch scale. b) Provide ceiling construction details. c) Provide suspended ceiling details complying with IBC 803.9.1.1. Show seismic bracing details. d) Show the location of all emergency lighting and exit signage. e) Detail the seismic bracing of the fixtures. f) Include alighting fixture schedule. 4. ❑ Framing Plan a) Specify the size, spacing, span and wood species or metal gage for all stud walls. b) Indicate all wall, beam and floor connections. c) Detail the seismic bracing for all walls. d) Include a stair section showing rise,run,landings, headroom,handrail and guardrail dimensions. 5. ❑ Storage Racks(if applicable) a) Structural calculations are required for seismic bracing of storage racks eight feet or greater in height. b) Eight feet or less,show a positive connection to floor or walls. NOTE:High pile storage shall meet the requirements of current International Building and Fire Codes. C. ❑ SPECIAL INSPECTION 1 Where special inspection is required by IBC 1704,the registered design professional in responsible charge shall prepare a special inspection program that will be submitted to the City of Arlington and approved prior to issuance of the building permit to comply with IBC 106.1. D. ❑ WASHINGTON STATE ENERGY CODE 1.One(1)completed Washington State Non-Residential Energy Code Envelope Summary forms. E. OCCUPANT'S STATEMENT OF INTENDED USE 1. The Occupant's Statement of Intended Use form shall be completely filled out and may require the submittal of a Hazardous Materials inventory Statement(HMIS). Contact the Arlington REV 2015 Page 4 of 9 Y O f COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community & Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 The building permit does not include any mechanical, electrical, plumbing or fire sprinkler/alarm work. These permits are issued separately.Mechanical, electrical, plumbing, or fire sprinkler/alarm permits require a separate permit application and may also require separate plan review. Please note that any tenant improvement work in a space that involves food handling or preparation requires Snohomish County Health District approval before the permit can be issued.You must provide the Permit Center a copy of the approval letter or the approved plans. Contact the Snohomish County Health District at(425) 339-5250 with any questions or for more information. An intake appointment is required for all large Tenant Improvement Building Permit Applications. To determine if your project requires an intake appointment,to schedule an appointment or to ensure that you have the most current information,please contact the City of Arlington Permit Center at(360)403-3551 or by email to ced@ariingtonwa.gov. Incomplete applications will not be accepted. I acknowledge that all items designated as submittal requirements must accompany my Building Permit Application to be considered a complete submittal. REV 2015 Page 5 of 9 COMMERCIAL APPLICATION ING' PERMIT SUBMITTAL Department of Community & Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 THIS APPLICATION TO BE USED FOR NEW COMMERCIAL STRUCTURES AND RESIDENTIAL DWELLINGS NOT REGULATED UNDER THE IRC. THIS APPLICATION MUST BE ACCOMPANIED BYA COMMERCIAL APPLICATION SUBMITTAL CHECKLIST AND AN OCCUPANT'S STATEMENT OF INTENDED USE. Name of Project:ROYAL STORAGE Valuation: $4 MIL Project Address: 17011 59TH AVE NE, ARLINGTON, WA 98223 Parcel ID#: 31052700100800 Legal Description NE 1/4 27-31-05 Owner: ROYAL STORAGE, LLC Phone Number: 425-760-8689 Address: 13600 44TH ST NE City: LAKE STEVENS State:WA Zip Code:98258 Englneer:PACIFIC SURVEYING & ENGINEERING Phone Number. 360-671-7387 Cell Phone: 360-815-3885 E-mail: DGALBRAITHCa PSESURVEY.COM Address: 909 SQUALICUM WAY STE 111 City: State:BELLINGHAM WA Zip Code:98225 General Contractor:SHARP DESIGN & BUILD, LLC Phone Number:425-760-8689 Cell Phone: 425-760-8689 E-mail: TROY@SHARPDESIGNBUILD.COM Address:13600 44TH ST NE City. LAKE STEVENS State: WA Zip Code: 98258 Contractor's License Number:S HARPDB852KK Expiration:05-30-202 1 Contact Person: TROY VAN KOPP Phone Number: 425-760-8689 Cell Phone: 425-760-8689 E-mail:TROY@S HARPDESIGN BU ILD.COM Address: 13600 44TH ST NE City:LAKE STEVENS State: WA Zip Code: 98258 Proposed Scope of Work:NEW SELF-STORAGE FACILITY REV 2015 Page 6 of 9 y COMMERCIAL APPLICATION PERMIT SUBMITTAL Department of Community & Economic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360) 403-3551 Project Name/Tenant ROYAL STORAGE Site Address17011 59TH AVE NE, ARLINGTON, WA 98223 Bldg/Unit/Suite IBC Construction Type II-B IBC Occupancy Type B.S1.0 Description of Use SELF-STORAGE Building Square Footage 73,620 including 30,600 Canopy Number of Stories Office 2: All others 1 Square Footage Per Floor First Floor: 41,900, Second Floor: 1,120, Canopy: 30,600 Will there be any installation, modification or removal of the following?(Check all that apply) ❑ Automatic fire extinguishing systems ❑ Compressed gas systems ❑ Fire alarm and detection systems ❑ Fire pumps ❑ Flammable and combustible liquids(tanks,piping etc...) ❑ Hazardous materials ❑ High piled/rack storage ❑ Industrial ovens/furnace 1Z Private fire hydrants ❑ Spraying or dipping operations ❑ Standpipe systems ❑ Temporary membrane structure,tents(>200sq ft)or canopies(>400 sq ft) Provide details on any of the above checked items: Installation,changes,modifications or removal of any of the above may require additional submittals, information, or permits during the plan review or construction process. Statement of Special Inspection REV 2015 Page 7 of 9 -- COMMERCIAL APPLICATION PERMIT SUBMITTAL INC'`ti��' Department of Community & Ec onomic Development City of Arlington• 18204 59th Ave NE• Arlington,WA 98223• Phone(360)403-3551 ROYAL STORAGE Name of Project: Project Address: 17011 59TH AVE NE, ARLINGTON, WA 98223 Special Inspection Firm: Address: Contact Person: Phone: Email: Special Inspection Firm Special Inspectors: The Special inspection Firm of will perform special inspection for the following types of work(separate forms must be submitted if more than one firm is to be employed). (V) Reinforced Concrete ( ) Bolting in Concrete ( ) Pre-stressed Concrete ( ) Shotcrete V) Structural Masonry V) Structural Steel and Welding ( ) High-Strength Bolting ( ) Spray-Applied Fireproofing ( ) Smoke-Control Systems ( ) Other Specify: All individual inspectors to be employed on this project will be WABO certified for the type of inspection they are to perform. If inspection is for work that is not covered by the WABO categories,a detailed resume of the inspector and firm must be submitted.The resume must show the inspector and firm are qualified to perform the work and testing required by the project design and specifications. The work shall be inspected for conformance with the plans and specifications approved by the City. Revisions and addenda sheets will not be used for inspection unless approved by the City.The special inspector shall report to the City revisions that are not approved. A daily record will be maintained on site itemizing the inspections performed,for the review of all parties.Any nonconforming items shall be brought to the immediate attention of the contractor for resolution. A weekly shall be submitted to the City;detailing the inspections and testing performed, listing any nonconforming items and resolution of nonconforming items.Unresolved nonconforming items will be detailed on a discrepancy report and presented to the building department. A final report shall be submitted to the Building Division priorto the Certificate of Occupancy being issued.This report will indicate that inspection and testing was completed in conformance with the approved plans,specifications and approved revisions and addenda. Any unresolved discrepancies must be detailed in the final report. The special inspector and special inspection firm serve in the role as"deputy"City of Arlington inspectors and as such are responsible to the City of Arlington Building Division in the performance of the required work. Contractor: The contractor shall provide the special inspector or agency adequate notification of work requiring inspection. The City approved plans and specifications must be made available,at the job site for the use of the special inspector and the City Inspector.The contractor shall maintain all daily inspections reports, on site,for review. REV 2015 Page 8 of 9 G1 y �r COMMERCIAL APPLICATION '�►lr ��' PERMIT SUBMITTAL Department of Community 8r Economic Development City of Arlington• 18204 59th Ave NE• Arlington, WA 98223 • Phone(360)403-3551 The special inspection functions are considered to be in addition to the normal inspections performed by the City and the contractor is responsible for contacting the City to schedule regular inspections.No concrete shall be poured or other work covered until approved by the City Inspector. Building Division: The Building Division shall review any revisions and addenda.Approved copies will be given to the contractor to maintain as part of the approved plan set. The City Inspector will monitor the special inspection functions for compliance with the agreement and the approved plans. The City Inspector shall be responsible for approving various stages of construction to be covered and work to proceed. Design Professionals: The architect and engineer will clearly indicate on the plans and specifications for the specific types of special inspection required, and shall include a schedule for inspection and testing. The architect and engineer will coordinate their revisions and addenda process in such a way as to insure all required City approvals are obtained,prior to work shown on the revisions being performed. Owner: The project owner, or the architect or engineer acting as the owners agent, shall employ the special inspector or agency. ENFORCEMENT: A failure of the special inspector or firm to perform in keeping the requirements of the IBC,the approved plans and this document may void this agreement and the Building Officials approval of the special inspector. In such case a new special inspector and/or firm would need to be proposed for approval.A failure of the design and/or construction parties to perform in accordance with this agreement may result in a STOP WORK notice being posted on the project,until nonconforming items have been resolved. ACKNOWLEDGEMENTS I have read and agree to comply with the terms and conditions of this agreement. Owner:TROY VAN KOPP Date: I hereby certify that the above information is correct and that the construction on,and the occupancy and the use of the above-described property will be in accordance with the laws,rules and regulation of the State of Washington. Applicants Signature TROY VAN KOPP Print Applicants Name Date FOR STAFF USE ONLY R�e,ceived Permit# Accepted By Amount Received Receipt# J�idkR REV 2015 Page 9 of 9 CITY OF ARLINGTON 1 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:17011 59th Avenue NE,Bldg C Permit#:2609 Parcel#:31052700100800 Valuation:2153322.00 OWNER APPLICANT CONTRACTOR Name:PREMIER PACIFIC PROPERTIES LLC Name:Sharp Design&Build,Inc. Name:Sharp Design&Build,LLC Address: 13600 44TH ST NE Address:13600 44th Street NE Address: 13600 44th Street NE City,State Zip:LAKE STEVENS,WA 98258 City,State Zip:Lake Stevens,WA 98258 City,State Zip:Lake Stevens,WA 98258 Phone: Phone:425-760-8689 Phone:425-760-8689 LIC:SHARPDB852KK EXP:05/30/2021 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Conn nlerclal New CODE YEAR: 2015 STORIES: I CONST.TYPE: 11-B DWELLING UNITS: O OCC GROUP: S-1 BUILDINGS: 1 OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC IOARCI10. SALES ES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form a o C' ington#3101. a -i/-/ I/ Signature Print Name Date Refiaord By OF bate CONDITIONS Approved job copy shall be on site for inspections. Adhere to approved plans. Call for inspections. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 7/11/2019 Building Permit Fee $14,501.98 7/11/2019 Building Plan Review Fee $9,426.29 7/11/2019 Processing/Technology Fee $25.00 7/11/2019 State Surcharge-Commercial $25.00 Total Due: $23,978.27 Total Payment: $0.00 Balance Due: $23,978.27 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 2609 Permit Date: 06/12/19 Permit Type: COMMERCIAL BUILDING Project Name: Royal Storage Applicant Name: Sharp Design& Build, Inc. Applicant Address: 13600 44th Street NE Applicant, City, State, Zip: Lake Stevens, WA 98258 Contact: Troy Van Kopp Phone: 425-760-8689 Email: troy@sharpdesignbuild.com Scope of Work: Storage and Office Valuation: 2153 322.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: CIC Permit Issued: 07/11/2019 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Property Parcel# Address Legal Description Owner Name Owner Phone Zoning Section 27 Township 31 Range 05 Quarter NE1/4- PAR 2 OF BLA REC AFN 200108315002 EXC TH PTN OF SD PAR 2 LY N 31052700100800 17011 59th Avenue NE OF S LN OF PAR 1 OF SD PREMIER PACIFIC 910 Undeveloped BLA PROJ ELY TO E LN PROPERTIES LLC (Vacant)Land OF SD PAR 2&EXC RDS -AKA PAR 2 OF CITYOF ARL BLA NO Z-06-015- BLA REC AFN 200606055267 Contractors Contractor Primary Contact Phone Address Contractor Type License License Sharp Design&Build, 13600 44th Street CONSTRUCTION LLC Troy Van Kopp 425-760-8689 NE CONTRACTOR Fees Fee Description Notes Amount Building Permit Table 4-1 $14,501.98 Building Plan Review Table 4-2 $9,426.29 Processing/Technology $25.00 State Surcharge-Commercial Commercial Only $25.00 Total $23,978.27 Attached Letters Date Letter Description 07/11/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 07/17/2019 Royal Storage Check#1072 Kristin Foster $23,978.27 Outstanding Balance $0.00 Notes Date Note Created By: 09/21/2021 C of O Issued Raelynn Jones 07/13/2020 Temp CO issued. Kristin Foster Uploaded Files Date File Name 07/13/2020 6964610-Royal Storage Bldg.C Temp CO.pdf 07/11/2019 5309147-2609 Issued Permit.pdf 07/11/2019 5308249-2609 Application.pdf CITY OF ARLINGTON TEMPORARY CERTIFICATE OF OCCUPANCY INTERNATIONAL BUILDING CODE SEC. 111 NOTE: THIS CERTIFICATE DOES NOT CERTIFY ELECTRICAL WORK At 1701159th Avenue NE Bldg. C Building Permit Number 2609 Name &Address of Owner Occupant Load Number of Stories ROYAL STORAGE LLC 1 13600 44TH ST NE Type of Construction/Sprinkler system required Use LAKE STEVEN,WA 98258 II-B/No Vehicle Storage THE Structure HAS BEEN INSPECTED AND APPROVED AS COMPLYING WITH THE 2015 EDITION OF THE INTERNATIONAL BUILDING CODE FOR GROUP S-2 OCCUPANCY ISSUED: July 10, 2020 BY Building Official