Loading...
HomeMy WebLinkAbout6919 Highland View Dr_BLD2588_2026 NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY APPROVED PERMIT#: 1- LOT#: DATE: 2 , JOBADDRESS: L114I10 VILLA TYPE OF INSPECTION: LILL It 610h ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK: MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 Z4 INSPECTOR DAT .0 BUILDING DEPT. O PLANNING DEPT. CITY OF ARLINGTON c ✓ .- 1 1 CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA, 98223 PHONE; (360)403-3551 BUILDING PERMIT Address:6919 Highland View Drive Permit 0:2588 Parcel if:00870600006200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:FERENCZY IENNIFER/DOMINIC Name:Brennan Heating Name: Brennan Heating Address:6919 IIIGIILAND VIEW DR Adtlress:4601 S 1341h Place Address:4601 S 134th Place City,State Zip:ARLINGTON,WA 98223 City,State Zip:Seattle,WA 98168 City,State Zip:Seattle,WA 08168 Phone: Phone:206-248-7900 Phone:206-248.7900 LTC:BRENNHA971R9 EXP: 12/29/2019 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Brennan Heating Name: Address.4601 S 134th Place Address: City,Slate,Zip:Seattle,WA 98168 City,State,Zip: Phone: 206.248-7900 Phone: L1C 0:BRENNHA971 R9 EXP: 12/29/2019 LTC H EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: 1 OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGRF..F TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL HE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THF.STATE OI'WASHING'rON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18,27, THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL PEES ARE PAID, 1T IS UNLAWFUL TO USE OR OCCUPY A BUILDING Olt STRUCTURE UNTIL A FINAL INSPEC ITON HAS BEEN MADF AND APPROVAL.OR A Jed ICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1 Ill/IR(_'110. AX Nor" S•1 s tax relating to construction and construction materia sin to City of Arli - r e p ned on your sales tax return form and City of Arlingt 1310 L Signature Print Name Date i Inust Ily Dade CONDITIONS Approved as submitted. Adhere to approved appliances. 3" concrete pad with seismic bracing attached to pad is required. Electrical disconnect is required. Lines shall be insulated and the use of adhesive tape is not allowed. THIS PERMIT AUTIIORIZS ONLY THE:WORK NOTED.THIS PERMIT COVFRS WORK TO BF.DONE ON PRIVATE PROPERTY ONLY ANY Ct1NSTRU(:110N ON T'IIF PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,P:TC.)WILL REQUIRE SEPARATE PFRMISSICIN. PERMIT FEES Date Description Fee Amount 6/3/2019 A/C Unit $25.00 6/3/2019 Furnace $25,00 6/3/2019 Mechanical Permit Base Fee $25,00 6/3/2019 Processing/Technology Fee $25.00 Total Due: $100,00 Tatal Payment: 50.00 Balance Due: S100.011 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an Inspection please leave the following;information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon i .� i �, 0 GITY OF ARUAGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:6919 Highland View Drive Permit#:2588 Parcel#:00870600006200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:FERENCZY JENNIFER/DOMINIC Name:Brennan Heating Name:Brennan Heating Address:6919 HIGHLAND VIEW DR Address:4601 S 134th Place Address:4601 S 134th Place City,State Zip:ARLINGTON,WA 98223 City,State Zip:Seattle,WA 98168 City,State Zip:Seattle,WA 98168 Phone: Phone:206-248-7900 Phone:206-248-7900 LIC:BRENNHA971R9 EXP: 12/29/2019 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Brennan Heating Name: Address:4601 S 134th Place Address: City,State,Zip:Seattle,WA 98168 City,State,Zip: Phone: 206-248-7900 Phone: LIC#:BRENNHA97IR9 EXP: 12/29/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC l0/IRCI10. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arli rted on your sales tax return form and coded City of Arlington#3101. 2 Signature Print Name Date leased Fay Date CONDITIONS Approved as submitted. Adhere to approved appliances. 3" concrete pad with seismic bracing attached to pad is required. Electrical disconnect is required. Lines shall be insulated and the use of adhesive tape is not allowed. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 6/3/2019 A/C Unit $25.00 6/3/2019 Furnace $25.00 6/3/2019 Mechanical Permit Base Fee $25.00 6/3/2019 Processing/Technology Fee $25.00 Total Due: $100.00 Total Payment: $0.00 Balance Due: $100.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon �, 1 1 I i Permit Information Date 6/3/2019 Permit Number 2588 Project Name Ferenczy Applicant Name Brennan Heating Applicant Address 4601 S 134th Place City,State,Zip Seattle,WA 98168 Contact Jaimie How Phone 206-248-7900 Email jaimie@brennanheating.com Permit Type Residential Mechanical Site Address 6919 Highland View Drive Valuation 0.00 Status Ready to Issue Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Number of Stories 0 Proposed Use Install A/C and replace furnace MIC/Opportunity Zone Assigned To Kristin Foster Property Parcel Address Legal Owner Owner Phone Zoning 00870600006200 6919 HIGHLAND VIEW DR I IFERENCZY JENNIFER/DOMINIC 111 Single Family Residence-Detached Contractors Contractor Primary Phone Email Contractor Type License License# Name Contact Brennan Heating Jaimie How 206-248- aimie@brennanheating.comMECHANICAL Labor and BRENNHA971R9 7900 CONTRACTOR Industries Fees Fee Description Notes Amount A/C Unit 322.10.00.00 $25.00 Furnace 322.10.00.00 $25.00 Mechanical Permit Base Fee 322.10.00.00 $25.00 Processing/Technology Fee 341.43.00.02 $25.00 Total $100.00 Uploaded Files Upload File Date File UDloaded B 6/3/2019 10:09:25 AM 12588 Application and Submittal Docs.pdf Foster,Kristin x I ,� I �� I RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE -Arlington,WA 98223 - Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES, PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: U Project Description; -,A t a c�t:2: � 2Y �^ Owner: Address: CyGl ta' t-1 Q111 cl �J t �w tr 'C� 1 not�6n t�Cl 9B22 ') Phone: L12e q Email: Applicant: Brennan Heating Address: 4601 S 134th PI Seattle 98168 Phone: 206-248-7900 Email: Jaimie@brennanheating.com Applicant Signature ` !: !n.Q_%-e.U_ Electronic Sig ure if submitting on-line 1 hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. CONTRACTOR INFORMATION Contractor Name:Brennan Heating Company: Brennan Heating License Number:BRENNHA971 R9 Expiration: 12/29/I Cj Phone:206-248-7900 Email:Jaimie@brennanheating.com STAFF USE ONL Received Permit : 2�'�`� Accepted by: Date: JUN 0 3 2019-_ i .. , I ii � � ' RESIDENTIAL MECHANICAL PERMIT APPLICATION W Department of Community & Economic Development City of Arlington• 18204 59th Ave NE • Arlington,WA 98223 • Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ ❑ Heat Pump ❑ Freestanding Stove ❑ Hydronic Piping ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System ❑ Boiler ❑ Gas Piping ❑ Storage Tank AC Unit Q Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance From Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to a feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances it I i I �: I SPECIFICATIONS General Model No. All Regions EL16XC1-018 EL16XC1-024 EL16XC1-030 EL16XC1-036 Data Southeast and North Regions --- --- --- EL16XCIS036 Nominal Tonnage 1.5 2 2.5 3 Connections Liquid line(o.d.)-in. 3/8 3/8 318 3/8 (sweat) Suction line(o.d.)-in. 3/4 3/4 3/4 7/8 Refrigerant 'R-010A charge furnished 4 lbs.9 oz. 4 lbs.9 oz. 5 lbs.8 oz. 8 lbs.0 oz. Outdoor Net face area-sq.ft. Outer coil 13.22 16.33 21.00 18.67 Coil Inner coil --- --- --- 17.96 Tube diameter-in. 5/16 5/16 5/16 5116 No.of rows 1 1 1 2 Fins per inch 26 26 26 22 Outdoor Diameter-in. 18 22 22 22 Fan No.of blades 3 3 3 3 Motor hp 1/10 116 1/6 1/6 Cfm 2290 3160 3160 3160 Rpm 1075 825 825 825 Watts 160 215 215 190 Shipping Data-lbs. 1 pkg. 155 171 187 220 ELECTRICAL DATA Line voltage data-60hz 208/230V--1ph 208/230V 1ph 2081230V 1ph 208/230V-1ph 1 Maximum overcurrent protection(amps) 20 25 25 30 Minimum circuit ampacity 11.9 14.6 17 18.6 Compressor Rated load artips 9.0 10.9 12.8 14.1 Locked rotor amps 48 59.3 67.8 83 Power factor 0.97 0.97 0.97 0.96 Outdoor Fan Motor Full load amps 0.7 1 1 1 1 Locked rotor amps 1.3 1.9 1.9 1.9 CONTROLS [Comfort®E30 Smart WI-Fi Thermostat 15S63I I Remote Outdoor Temperature Sensor X2658I OPTIONAL ACCESSORIES-ORDER SEPARATELY Compressor Crankcase Heater 93M04 Compressor Hard Copeland 1OJ42 Start Kit LG 88M91 Compressor Low Ambient Cut-Off Switch 45F08 Compressor Timed-Off Control 47,135 Freezestat 3/8 in.tubing 93G35 518 in.tubing 50A93 • Indoor Blower Off Delay Relay 58M81 Loss of Charge Switch Kit 84M23 4 Low Ambient Kit(Fan Cycling) 34M72 Refrigerant L15-41-20 L1541-40 Line Sets L15-41-30 L1541-50 L15-65-30 L15-65-00 • L15-65-50 NOTE-Extremes of operating range are plus 10%and minus 5%of line voltage. Refrigerant charge suf elent for 151t.length of refrigerant lines.For longer line set requirements see the Installation Instructions for inrarmaUCt1 stlpu!i,inB sec l�r�grn MIA additional refrigerant charge required. z HACR type breaker or fuse. I'I A' O �O+n 'Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. J U N I J Crankcase Heater and Freezestat are recommended with Low Ambient Kit. EL16XCI-1.5 to 5 Ton Air Conditioner /Paae 7 I 1 I �� I .= SPECIFICATIONS Gas Model No. SL28ODF07OV36A SL28ODF09OV48B SL28ODFOSOV60C SL28ODF110VOCC Heating AHRI Ref,No. 3845340 3845341 3845342 3845343 Performance 'AFUE 80% 80% 80% 80% High Input-Btuh 66,000 88,000 88,000 110,000 Fire Output-Btuh 52,000 69,000 70,000 87,000 Temperature rise range-'F 35-65 35-65 35-65 35-65 Gas Manifold Pressure(In.w.g.) 3.51 10.0 3.5/10.0 3.51 10.0 3.5/10.0 Nat.Gas/LPG/Propane Low Input-Btuh 43,000 57,000 57,000 72,000 Fire Output-Btuh 35,000 46,000 46,000 59,000 Temperature rise range-°F 25-55 25-55 25-55 25-55 Gas Manifold Pressure(in.w.g.) 1.7/4.9 17/4.9 1.7/4.9 1,7/4,9 Nat,Gas/LPG/Propane High static-In.w.g. Heating 0.8 0.8 0,8 0.8 Cooling 1.0 1.0 1.0 1.0 Connections Flue connection-in,round 4 4 4 4 In. Gas pipe size IPS 1/2 1/2 112 1/2 Indoor Wheel nominal diameter x width-in, 10 x 8 11 x 9 11 x 10 11 x 10 Blower Motor output-hp 1/2 1 1 1 Tons of add-on cooling 2-3 3-4 3.5-5 3.5-5 Air Volume Range-cfm 589-1514 830-1996 899-2273 1 882.212D Electrical Voltage 120 volts-60 hertz-1 phase Data Blower motor full load amps 7.7 12.8 12.8 12.8 Maximum overcurrent protection 15 20 20 20 Shipping Data lbs.-1 package 1 130 153 164 173 NOTE-Fillers and provisions for mounting are not fumishad and must be field provided, 'Annual Fuel UtiMation Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces. OPTIONAL ACCESSORIES -ORDER SEPARATELY NOTE-FURNACES CANNOT BE TWINNEDI "A"Width "B"Width "C"Width Models Models Models CABINET ACCESSORIES Downflow,Combustible Flooring Base I 11M59 I 11M60 I 11M61 CONTROLS IComfortm S30 Ultra-Smart Wi-Fl Thermostat 121.167 12U67 121.167 ' Discharge Air Temperature Sensor 88K38 88K38 88K38 iComfort"M30 Smart WI-Fi Thermostat ISZ69 15Z69 15Z69 2 Remote Outdoor Air Temperature Sensor X2658 X2658 X2658 (for dual fuel and Humiditrols') DOWNFLOW FILTER KITS Downflow Filter Cabinet I 51 WO6 I 51 W07 51 W08 No.and Size of filter-in. (1)20 x 20 x 1 (2)16 x 20 x 1 (2) 16 x 20 x 1 NIGHT SERVICE KIT Night Service Kit ! 16S36 16S36 ! 16S36 'Optional for service diagnostics. 'Remole Outdoor Air Temperature Sensor is used with conventional(non4Comforr Communicating)outdoor units(sensor is furnished with iComfore Communicating outdoor units),Allows the thermostat to display outdoor temperature,Required In dual-fuel and EDA applications. 'Cleanable poyurethane,frame-type filler. Received JUN 0 3 2019 17ZC-6t SL2800FV I Pape 8 i r, r room%Val FECZsor-sq LEN►� EQ.��4r�E*� 6ct\q Vksw OR G (VAt-3 S� z8opfoZOV3bA C�r1 Or P►4t�.�N6zo� p,�C l���.1 E�.16�C1 •030 em � � I W I 1 -LA, 30• S Received JUN 0 3 2019 P,:� v zAG% �.1�N�AN'�a VIEW OR 1 I Search I_CI `�— i ' Labor Safety&Health Claims&Insurance Workplace Rights Trades AWashington State Department of Labor & Industries BRENNAN HEATING &A/C LLC Owner or tradesperson 4601 S 134TH PL Principals SEATTLE,WA 98168 ERDAHL,DARRIN PAUL,PARTNER/MEMBER 206-248-7900 KING County Doing business as BRENNAN HEATING&A/C LLC WA UBI No. Business type 602 346 866 Limited Liability Company Governing persons DARRIN P ERDAHL ERIC BEARDEMPHL; Certifications & Endorsements License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. BRENNHA971R9 Effective—expiration 12/29/2003-12/29/2019 Bond FEDERATED MUTUAL INS CO $12,000.00 Bond account no. 9127230 Received by L&I Effective date 11/04/2004 12/22/2004 Expiration date Until Canceled Insurance Federated Mutual Ins Co $1,000,000.00 Policy no. 9820726 Received by L&I Effective date 05/29/2019 07/13/2015 Expiration date 0 711 3/2 0 2 0 Insurance history Savings No savings accounts during the previous 6 year period. Help us improve Lawsuits against the bond or savings No lawsuits against the bond or savings acc( :during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations Infraction no. PDOVE00515 Satisfied Issue date RCW/WAC 01/26/2018 18.106.020 Violation city Violation amount SEATTLE $250.00 Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman,specialty or trainee certificate, temporary permit or medical gas endorsement as required. Workers' comp Public Works Requirements Workplace safety and health Iu.�1Vashin$ton• Help us improve CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:6919 Highland View Drive Permit#:2588 Parcel il:00970600006200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:FERENCZY]E•NNIFER/DOMINIC Name:Brennan Heating Name: Brennan Heating Address:6919 I IIGHLAND VIEW DR Address:4601 S 134th Place Address:4601 S 134th Place City,State Zip:ARLINGTON,WA 98223 City,State Zip:Seattle,WA 98108 City,State Zip:Seattic,WA 98168 Phone: Phone:206-248-7900 Phone:206-248-7900 LIC:BRENNI IA97 I R9 EXP: 12/29/2019 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Brennan Heating Namc: Address:4601 S 134th Place Address: City,State,'Lip:Seattle,WA 98168 City,State,Zip: Phone: 206-248-7900 Phone: LIC#:BRENNHA97I R9 EXP: 12/29/2019 LIC#: F.XP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE,TO COMPLY WITH CITY AND STATE.LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED TIIF.RF.IIY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE.LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A FICATE OF OCCUPANCY HAS BEEN GRANTED. IBCi ltl/IRC110. ALE. TAX NOTICE:Sails tax relating to construction and construction materia s in e City of Arli a p Ned on your sales tax return form and c cd City of Arlingt 310I. Signature Print Namc Date lease By Date CONDITIONS Approved as submitted. Adhere to approved appliances. 3" concrete pad with seismic bracing attached to pad is required. Electrical disconnect is required. Lines shall be insulated and the use of adhesive tape is not allowed. THIS PERMIT AUT110RIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO OF DONE ON PRIVATE PROPERTY ONLY, ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,Fl-C.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 6/3/2019 A/C Unit S25.00 6/3/2019 Furnace $25.00 6/3/2019 Mechanical Permit Base Fee $25.00 6/3/2019 Processing/Technology Fee $25.00 Total Due: S100.00 Total Payment: $0.00 Balance Due: $100.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following;information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE • Arlington,WA 91;223 • Phone (360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. FLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: q VA CAh 1 mac- v i ��Y' 'P�r\�r-,Q \- p G�223 Project DescriptionArl-15-F1V-d - ne ka crx1-6-I'sY i -Fvrr��1C Owner: Address: IGf Der- Phone: �12�- 22q3 - LA Z` q Email: Applicant: Brennan Heating Address: 4601 S 134th PI Seattle 98168 Phone: 206-248-7900 Email: Jaimie@brennanheating.com Applicant Signatur - Electronic Sig ure if submitting on-line 1 hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State, of Washington. CONTRACTOR INFORMATION Contractor Name:Brennan Heating Company: Brennan Heating License Number:BRENNHA971 R9 Expiration: 12/29/I G_ Phone:206-248-7900 Email:Jaimie@brennanheating.com STAFF USE ONLY Permit #: Accepted by: Date: RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE • Arlington,WA 98223 • Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) ❑ Fireplace Insert ❑ Outdoor BBQ ❑ Heat Pump ❑ Freestanding Stove ❑ Hydronic Piping ❑ Type II Hood ❑ Commercial Cooking Appliance ❑ PV System ❑ Boiler ❑ Gas Piping ❑ Storage Tank AC Unit ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance From Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test to hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances SPECIFICATIONS General Model No. All Regions EL16XCl-018 EL16XC1-024 EL16XCI.030 EL16XC1-036 Data Southeast and North Regions --- --- --- EL16XC1S036 Nominal Tonnage 1.5 2 2.5 3 Connections Liquid line(o.d.)-in. 3/8 3/8 318 3/8 (sweat) Suction line(o.d.)-in. 3/4 3/4 3/4 7/8 Refrigerant 'R-410A charge fumished 4 lbs.9 oz. 4 lbs.9 oz. 5 lbs.8 oz. 8 lbs.0 oz. Outdoor Net face area-sq.ft. Outer coil 13.22 16.33 21.00 18.67 Coil Inner coil --- --- --- 17.96 Tube diameter-in. 5/16 5/16 5/16 5/16 No.of rows 1 1 1 2 Fins per inch 26 26 26 22 Outdoor Diameter-in. 18 22 22 22 Fan No.of blades 3 3 3 3 Motor hp 1/10 1/6 1/6 1/6 Cfm 2290 3160 3160 3160 Rpm 1075 825 825 825 Watts 160 215 215 190 Shipping Data-lbs. 1 pkg. 155 171 187 220 ELECTRICAL DATA Line voltage data-60hz 2081230V 1ph 208/23OV 1ph 2081230V 1ph 208/230V-1ph 'Maximum overcurrent protection(amps) 20 25 25 30 Minimum circuit ampacity 11.9 14.6 17 18.6 Compressor Rated load amps 9.0 10.9 12.8 14.1 Locked rotor amps 48 59.3 67.8 83 Power factor 0.97 0.97 0.97 0.96 Outdoor Fan Motor Full load amps 0.7 1 1 1 Locked rotor amps 1.3 1.9 1.9 1.9 CONTROLS (Comfort®E30 Smart WI-FI Thermostat 15S63 • Remote Outdoor Temperature Sensor X2658 • OPTIONAL ACCESSORIES- ORDER SEPARATELY Compressor Crankcase Heater 93M04 • Compressor Hard Copeland 1OJ42 • Start Kit LG 88M91 • Compressor Low Ambient Cut-Off Switch 45F08 • Compressor Timed-Off Control 47.135 • Freezestat 3/8 in.tubing 93G35 • 518 in.tubing 50A93 • Indoor Blower Off Delay Relay 5BM81 • Loss of Charge Switch Kit 84M23 • *1-ow Ambient Kit(Fan Cycling) 34M72 • Refrigerant L15-41-20 L1541-40 • Line Sets L15-41-30 L15-41-50 L15-65-30 L15-65-40 • L15-65-50 NOTE-Extremes of operating range are plus 10%and minus 5%of line voltage. 'Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the Installation Instructions for Information about line set length and additional refrigerant charge required. s HACR type breaker or fuse. 'Refer to National or Canadian Electrical Code manual to determine wire,fuse and disconnect size requirements. 'Crankcase Heater and Freezestat are recommended with Low Ambient Kit. EL16XC1 -1.5 to 5 Ton Air Conditioner !Page 7 SPECIFICATIONS Gas Model No. SL280DF070V36A SL28ODF09OV48B SL28ODF090V60C SL28ODF11OV60C Heating AHRI Ref.No. 3845340 3845341 3845342 3845343 Performance 'AFUE 80% 80% 80% 80% High Input-Btuh 66,000 88,000 88,000 110,000 Fire Output-Btuh 52,000 69,000 70,000 87,000 Temperature rise range-°F 35-65 35-65 35-65 35-65 Gas Manifold Pressure(in.w.g.) 3.5/10.0 3.5/10.0 3.5/10.0 3.5/10.0 Nat.Gas/LPG/Propane Low Input-Btuh 43,000 57,000 57,000 72,000 Fire Output-Btuh 35,000 46,000 46,000 59,000 Temperature rise range-°F 25-55 25-55 25-55 25-55 Gas Manifold Pressure(in.w.g.) 1.7/4.9 1.7/4.9 1.714.9 1.7/4.9 Nat.Gas/LPG/Propane High static-in.w.g. Heating 0.8 0.8 0.8 0.8 Cooling 1.0 1.0 1.0 1.0 Connections Flue connection-in.round 4 4 4 4 In. Gas pipe size IPS 1/2 1/2 1/2 1/2 Indoor Wheel nominal diameter x width-in. 10 x 8 11 x 9 11 x 10 11 x 10 Blower Motor output-hp 1/2 1 1 1 Tons of add-on Cooling 2-3 3-4 3.5-5 3.5-5 Air Volume Range-cfm 589-1514 1 830-1996 899-2273 1 882-2120 Electrical Voltage 120 volts-60 hertz-1 phase Data Blower motor full load amps 7.7 12.8 12.8 12.8 Maximum overcurrent protection 15 20 20 20 Shipping Data lbs.-1 package 130 153 164 173 NOTE-Filters and provisions for mounting are not furnished and must be field provided. 'Annual Fuel UOUstion Efficiency based an DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces. OPTIONAL ACCESSORIES -ORDER SEPARATELY NOTE-FURNACES CANNOT BE TWINNED! "A"Width "B"Width "C"Width Models Models Models CABINET ACCESSORIES Downflow Combustible Flooring Base I 11M59 I 11M60 I 11M61 CONTROLS iComfort®S30 Ultra-Smart WI-Fi Thermostat 121.167 121.167 121.167 'Discharge Air Temperature Sensor 881(38 88K38 88K38 iComfort®M30 Smart Wi-Fi Thermostat 15Z69 15Z69 15Z69 2 Remote Outdoor Air Temperature Sensor X2658 X2658 X2658 (for dual fuel and HumiditmF) DOWNFLOW FILTER KITS Downflow Filter Cabinet I 51W06 I 51W07 I 51W08 No.and Size of filter-in. (1)20 x 20 x 1 (2)16 x 20 x 1 (2) 16 x 20 x 1 NIGHT SERVICE KIT Night Service Kit 16S36 16S36 16S36 'Optional for service diagnostics. 'Remote Outdoor Air Temperature Sensor is used with conventional(non-lComfort®Communicating)outdoor units(sensor is furnished with iComforV Communicating outdoor units).Allows the thermostat to display outdoor temperature.Required In dual-fuel and EDA applications. 'Cleanable polyurethane,frame-type filter. SL28ODFV/Page 8 morn%tJt 6gtq rV,1a SL zaopFc'lOV3bA Carl or Pe��.�N6To� p,�C M�� �L.�bi�C1 •030 SO I � � I tiu I I' eMcr� s' I w I � (jAQtAC�� 1 I I 30. 1A�Lw..p.w�a v�E.w DR B V�vj1 NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED Cl DO NOT OCCUPY XAPPROVED PERMIT#: OT#: DATE: j. 2. j JOBADDRESS: 1r�IGj \JjAJ I14i TYPE OF INSPECTION: Vip(+Ink i IL t"I h . I 1 A EZ IAt ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK:MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION 4:2 c zc L-1 z0 i THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE/ LUILDING DEPT. LANNING DEPT. CITY OF ARLINGTON . -- CITY OF ARLINGTON ' 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:6919 Highland View Drive Permit#:2588 Parcel#:00870600006200 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:FERENCZY JENNIFER/DOMINIC Name:Brennan Heating Name:Brennan Heating Address:6919 HIGHLAND VIEW DR Address:4601 S 134th Place Address:4601 S 134th Place City,State Zip:ARLINGTON,WA 98223 City,State Zip:Seattle,WA 98168 City,State Zip:Seattle,WA 98168 Phone: Phone:206-248-7900 Phone:206-248-7900 LIC:BRENNHA971R9 EXP: 12/29/2019 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Brennan Heating Name: Address:4601 S 134th Place Address: City,State,Zip:Seattle,WA 98168 City,State,Zip: Phone: 206-248-7900 Phone: LIC#:BRENNHA97IR9 EXP: 12/29/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC I01IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arli P i e rtcd on your sales tax return form and coded City of Arlington#3101. Signature Print Name Date lease By Date CONDITIONS Approved as submitted. Adhere to approved appliances. 3" concrete pad with seismic bracing attached to pad is required. Electrical disconnect is required. Lines shall be insulated and the use of adhesive tape is not allowed. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 6/3/2019 A/C Unit $25.00 6/3/2019 Furnace $25.00 6/3/2019 Mechanical Permit Base Fee $25.00 6/3/2019 Processing/Technology Fee $25.00 Total Due: $100.00 Total Payment: $0.00 Balance Due: $100.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit#: 2588 Permit Date: 06/03/19 Permit Type: RESIDENTIAL MECHANICAL Project Name: Ferenczy Applicant Name: Brennan Heating Applicant Address: 4601 S 134th Place Applicant, City, State, Zip: Seattle,WA 98168 Contact: Jaimie How Phone: 206-248-7900 Email:jaimie@brennanheating.com Scope of Work: Install A/C and replace furnace Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 06/04/2019 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Kristin Foster Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 6919 HIGHLAND VIEW FERENCZY 111 Single Family 00870600006200 DR JENNIFER/DOMINIC Residence- Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL COA 602 346 866 CONTRACTOR Brennan Heating Jaimie How 206-248-7900 4601 S 134TH PL MECHANICAL Labor and BRENNHA971R9 CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 07/02/2019 R04.PLUMBING 07/02/2019 BUILDING Completed GROUNDWORK 06/27/2019 R00.FURNACE PM 06/27/2019 BUILDING Completed FINAL A/C and Furnace Final Fees Fee Description Notes Amount Air Cond.Unit Btu/h<100>; $25.00 Btu/hp>500 Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Credit Card Service $3.00 Total $103.00 Attached Letters Date Letter Description 06/03/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 06/03/2019 Brennan Heating 75595891 iTransact CC $100.00 06/03/2019 Brennan Heating CC Surcharge Transaction $3.00 #75595891 Outstanding Balance $0.00 Notes Date Note Created By: 06/03/2019 Emailed permit for signature. Kristin Foster Uploaded Files Date File Name 09/22/2021 9741401-2588 Inspection-Final.pdf 06/04/2019 5149690-258 Issued Permit.pdf 06/03/2019 5140783-2588 Application and Submittal Docs.pdf