Loading...
HomeMy WebLinkAbout7726 Inverness Dr_BLD2525_2026 d5 NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL 11 CORRECTIONS REQUIRED ❑ VO NOT OCCUPY a APPROVED PERMIT M. l` ` LOT#: DATE: JOB ADDRESS: TYPE OF INSPECTION: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK:MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE I1 ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE (PER IBC) I,IUST fit: PiAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 Cl CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 7] INSPECTOR DAT 1 BUILDING DEPT, o PLANNING DEPT. CITY OF ARLINGTON i �, UTY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:7726 Inverness Dr. Permit#:2525 Parcel#:00865900007700 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:JOHNSON TERRY L/MARALYNN Name:Pilchuck Heating,LLC Name:Pilchuck Heating Address:7726 INVERNESS DR Address:1429 Ave.D Address: 1429 Avenue D,#224 City,State Zip:ARLINGTON,WA 98223-5047 City,State Zip:Snohomish,WA 98290 City,State Zip:Snohomish,WA 98290 Phone: Phone:425-501-5480 Phone:425-501-5480 LIC: EXP: MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Pilchuck Heating Name: Address: 1429 Avenue D Address: City,State,Zip:Snohomish,WA 98290 City,State,Zip: Phone:425-501-5480 Phone: LIC#:PILCHH*874PW EXP: 10/29/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington 7t is b reportJonour sales tax retu form and coded City of Arlington#3101. y Signature Print Name Date lca By ate CONDITIONS Adhere to approved appliance. Call for final inspection THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 4/25/2019 Furnace $25.00 4/25/2019 Mechanical Permit Base Fee $25.00 4/25/2019 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon r Permit Information Date 4/25/2019 Permit Number 2525 Project Name 7726 Inverness Dr Applicant Name Pilchuck Heating,LLC Applicant Address 1429 Ave.D City,State,Zip Snohomish,WA 98290 Contact Phone 425-501-5480 Email jefft@pilchuckheating.com Permit Type Residential Mechanical Site Address 7726 Inverness Dr. Valuation 0.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Residential Mechanical Number of Stories 0 Proposed Use Replace existing furnace Assigned To Raelynn Jones Property Parcel Address Legal Owner Owner Phone Zoning 00865900007700 17726 INVERNESS DR JOHNSON TERRY L/MARALYNN 111 Single Family Residence-Detached Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# IPilchuck Heatin leff Talbert 125-501-5480 efft ilchuckheatin .com CONTRACTOR t-abor and Industries IPILCHH"874PW Fees Fee Descri tion Notes Amount Furnace 322.10.00.00 $25.00 Mechanical Permit Base Fee 322.10.00.00 $25.00 Processing/Tech olo Fee 341.43.00.02 $25.00 Total $75.00 Uploaded Files Upload File Date File Uploaded B 4/25/2019 11:30:25 AM 2525 Specs.pdf Jones,Raelynn 4/25/2019 11:30:25 AM 2525 Application.pdf Jones,Raelynn { 1 I RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:7726 Inverness Dr. Arlington, WA 98223 Project Description:Replace existing furnace with new Owner: Terry L and Maralyn Johnson Address: 7726 Inverness Dr. City:Arlington StateYVA Zip Code: 98223 Phone: 4255850659 Email:pilchuckheating@pilchuckheating.com Applicant: Pilchuck Heating LLC Address: 1429 Ave. D #224 City: Snohomish State WA Zip Code: 982.90 Phone: 4255015480 Email: Jefft@pilchuckheating.com CONTRACTOR INFORMATION Contractor Narne:PIIchuck Heating LLC Address: 1429 Ave. D #224 City: Snohomish State WA Zip Code: 98290 License Number:PILCH H L823LN Expiration: 06/15/2020 Phone:4255015480 Email:Jefft@pilchuckheating.com STAFF USE O Received Permit #: � 25 Accepted by: DatEAPR 2 5 20t9 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL Ze PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223 • Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #DM96VC0603B AFUE96% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER [ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date: 04/25/2019 Applicant Printed Name: Jeffrey Talbert I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 Now woomr— Search L&I Aft N-Z UILa"bori Safety&Health 19 Claims&Insurance 1; Workplace Rights M Trades&Licensing M Washington State Department of " Labor & Industries PILCHUCK HEATING Owner or tradesperson 1429 AVE D#224 SNOHOMISH,WA 98290 Principals 425-585-0659 TALBERT,JEFFREY ALAN,OWNER SNOHOMISH County Doing business as PILCHUCK HEATING WA UBI No. Business type 603 341 412 Individual License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Relicensed. Contractor relicensed under another name, structure,or specialty. License specialties GENERAL License no. PILCHH*874PW Effective—expiration 1 0/1 6/201 3-1 0/29/2019 Bond No current bond account.See the bond history. Bond history Insurance No current insurance account.See the insurance history. Insurance history Savin. ....gs ......... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Cause no. 17-2-10950-9SEA Dismissed Complaint filed by Complaint against bond(s)or savings STATE OF WASHINGTON 100233428 Complaint date Complaint amount 05/04/2017 $6,000.00 Cause no. 1 5-2-11 220-1 SEA Dismissed Complaint filed by Complaint against bond(s)or savings STATE OF WASHINGTON 100233428 Complaint date Complaint amount 05/13/2015 $1,873.47 L&I Tax debts Help us improve No L&I tax debts are recorded for this contr )r license during the previous 6 year period,but sorr ibts may be recorded by other agencies. License Violations Infraction no. EJURT00757 Not Satisfied Issue date RCW/WAC 11/10/2016 19.28.041 RCW Violation city Violation amount SNOHOMISH $1,500.00 Type of violation ELECTRICAL CITATION Description Offering to perform,submitting a bid for, advertising,installing or maintaining cables, conductors or equipment that convey or utilize electrical current without having a valid electrical contractor license. Infraction no. EJURT00758 Not Satisfied Issue date RCW/WAC 11/10/2016 19.28.101 RCW Violation city Violation amount SNOHOMISH $1,000.00 Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain a valid electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296.46113-901. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is closed. 334,028-00 Doing business as PILCHUCK HEATING Estimated workers reported N/A L&I account contact T5/MELISSA VEST(360)902-5613-Email:VESM235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. improveHelp us •: F `� 1 r'DA,IKAFN DC96VC COMFORTNETm-COMPATIBLE TWO STAGE, VARIABLE-SPEED ECM-BASED GAS FURNACE UP To 96%AFUE HWING INPUT 40,000-120,000 BTU1H IN Contents Nomenclature........................................2 Accessories............................................2 Product Specifications...........................3 Dimensions............................................4 Airflow Specifications............................5 Wiring Diagram......................................8 r, ComfortNelIle ��" OMfROt fff flM ■ Standard Features ■ Cabinet Features • ComfortNet-communicating system compatible • Designed for multi-position installa- • Heavy-duty stainless-steel tubular heat exchanger lion—downflow,horizontal left or right • Stainless-steel secondary heat exchanger • Certified for direct vent(2-pipe)or • Two-stage gas valve provides quiet, non-direct vent(1-pipe) economical heating • Convenient left or right connection • Durable Silicon Nitride igniter for gas and electrical service • Quiet two-speed induced draft blower • Cabinet air leakage(QLeak)<_2% • Utilizes ComfortNef*communicating,two- • Heavy-gauge steel cabinet with durable finish stage or single-stage thermostats • Fully insulated heat exchanger • Self-diagnostic control board with constant memory and blower section fault code history output to a dual 7-segment display • Airtight solid bottom or side return with • Color-coded low-voltage terminals with provi- easy-cut tabs for effortless removal sions for electronic air cleaner and humidifier in bottom air-inlet applications • Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand • Multiple continuous fan speed options offer quiet air circulation • Auto-Comfort and enhanced `• • • cOPus dehumidification modes available• All models comply with California 40 ng/J Received Intertek Low NOx emissions standard APR 2 5 2019 • For installation in California's South Coast Air Quality Management District(SCAQMD)only:This furnace does rsoeon �VD not meet the SCAQMD Rule 111114 ng/J NOx emission limit,and thus is subject to a mitigation fee of up to$450. *Complete warranty details available from your local dealer or at ww w.dalkincomfort com. To receive the Lifetime Heat Exchanger Limited This furnace is not eligible for the SCAQMD Clean Air Warranty(good for as long as you own your home),the 12-Year Unit Replacement Limited Warranty and Furnace Rebate Pro ram:www.CleanAirFurnaceRebate.com, the 12-Year Parts Limited Warranty,online registration must be completed within 60 days ofinstallation. g Additional requirements for annual maintenance are required for the Unit Replacement limited Warranty. Online registration and some of the additional requirements are not required in California or Quebec. SS-DC96VC www.daikincomfort.com 9/18 Supersedes 4/18 NOMENCLATURE D C 96 V C 060 3 B N A A 1 2 3,4 5 6 7,8,9 10 11 12 13 14 Brand Minor Revision D-Daikin Brand A-Initial Release B-1st Revision Configuration M-Upflow/Horizontal Major Revision C-Downflow/Horizontal A-Initial Release B-1st Revision AFUE 97-97-98%AFUE 92-92%AFUE NOx 96-96%AFUE N- Low Nox(40ng/J) Gas Valve Cabinet Width M-Modulating H-Convertible Two-Stage B-17%" V-Two Stage S-Single Stage C-21" D-24%" Motor C-Variable Speed ECM/ComfortNet Maximum CFM E-Multi-Speed ECM S-Multi-Speed PSC 2- 800 CFM 3-1200CFM MBTU/h 4-1600 CFM 040-40,000 BTU/h 100-100,000 BTU/h 5-2000 CFM 060-60,000 BTU/h 120-120,000 BTU/h 080-80,000 BTU/h ACCESSORIES 0603BNA 0804CNA 1005CNA . CTK04 ComfortNet-Compatible Control V V V V V CVENT-2 Concentric Vent Kit(2") V V V V V CVENT-3 Concentric Vent Kit(3") V V V V V CFSB17 Downflow Sub-Base 17.5" V V ... CFSB21 Downflow Sub-Base 21" — V V — CFSB24 Downflow Sub-Base 24" --- --- — — V RF000142 Drain Kit-Horizontal Left Vertical Flue EFR02 External Filter Rack with 16"x2S"Permanent Filter V V V 0170K00000S Flush Mount Vent Kit-3"or 2" V V V V V 0170K00001S Flush Mount Vent Kit-2" V V V V V AFE18-60A Fossil Fuel(Dual Fuel)Kit V V V V V HASFK High-Altitude Natural Gas Kit HASFK-1 HASFK-1 HASFK-2 HASFK-3 HASFK-3 HASFK High-Altitude LP Gas Kit HASFK-1 HASFK-1 HASFK-2 HASFK-2 HASFK-3 LPLP03 Low LP Gas Pressure Switch V V V V V LPM-08 LP Conversion Kits V V V V V 2 www.daikincomfort.com SS-DC96VC PRODUCT SPECIFICATIONS 0603BNA 0804CNA00 Heating Data High Fire Input' 40,000 60,000 80,000 100,000 120,000 High Fire Output' 38,400 57,600 76,800 96,000 115,200 Low-Fire Steady-State Input' 28,000 42,000 56,000 70,000 84,000 Low-Fire Steady-State Output' 26,880 40,320 53,760 67,200 80,640 AFUE2 96 96 96 96 96 Temperature Rise Range(°F) 20-50 35-65 25-55 45-75 35-65 Vent Diameter' 2"-3" 2"-3" 2"-3" 2"-3" 2"-3" No.of Burners 2 3 4 5 6 Circulator Blower Available AC@0.5"ESP 1.5-3 1.5-3 1.5-4 2-5 2-5 Size (D x W) 10"x 8" 11"x 8" 11"x 10" 11"x 10" 11"x 11" Horsepower @ 1075 RPM %Z %z a/ 1 1 Speed VS ECM VS ECM VS ECM VS ECM VS ECM Electrical Data Min.Circuit Ampacity° 7.8 7.8 10.6 14.4 14.4 Max.Overcurrent Device(amps)' 15 15 15 20 20 Shipping Weight(Ibs) 116 119 143 145 158 Natural Gas BTU/h ' DOE AFUE based upon Isolated Combustion System(ICS) ' Installer must supply one or two PVC pipes:one for combustion air(optional)and one for the flue outlet(required).Vent pipe must be either 2"or 3"in diameter,depending upon furnace input,number of elbows,length of run and installation(1 or 2 pipes).The optional Combus- tion Air Pipe is dependent on installation/code requirements and must be 2"or 3"diameter PVC. Minimum Circuit Ampacity=(1.25 x Circulator Blower Amps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. 5 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply, • Gas Service Connection%"FPT • Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. • For bottom return:Failure to unfold flanges may reduce airflow by up to 180/.This could result in performance and noise issues. • For servicing or cleaning,a 24"front clearance is required.Unit connections(electrical,flue and drain) may necessitate greater clearances than the minimum clearances listed above.In all cases,accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. SS-DC96VC www.daikincomfort.com 3 DC96VC DIMENSIONS A 6% Z3 a- 1'/. ► +1 1'%° Alternate Vent/ Flue Location Low-Voltage Electrical Outlet Low-V"I[age Electrical Outlet la Alternate as 1 O Supply Location Alternate Gas Supply Hlgh•VOhige Location Electrical Outlet 0 1 O o 14%� 131: 1 ih'G O tlx 0 64 4'/e 0 Left-Side Eatefia High-Voltage I Drain Trap Holes O Electrical outlet 18Y. Standard Drain Trap Z UMolded Flmges connection W PVC 2X Unfolded Flanges EF 2'/.Z IOX 28'/a Folded 3Y: Folded Flanges langes Left-Side View Right-Side View Front View Right Side Exterior Aif Drain Trap Holes Air Discharge Discharge AIR RETURN AIR DISCHARGE DC96VC0403BNA 17Y2" 14W 14" 14Yz" 16" DC96VC06038NA 17Y:" 14Ya' 14" 14Y:" 16" DC96VC0804CNA 21" 18%" 17Yz" 18" 19YZ" DC96VC1005CNA 21" 18Ys" 17%" 18" 19%" DC96VC1205DNA 24Y2" 21W 21" 21%" 23" MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS SIDES 'REAR FRONT BOTTOM FLUE Top Downflow 0" 0" 3" NC 011 1" Horizontal 6" 0" 3" C 0" 6" C=If placed on combustible floor,the floor MUST be wood ONLY. NC=For installation on non-combustible floors only.A combustible floor sub-base must be used for installations on combustible flooring. 4 www.daikincomfort.com SS-DC96VC DC96VCAIRFLow DATA DC96VC0403BNA DC96VC0403ONA COOLING SPEEDS HEATING SPEED (@.1"-.8"W.C.ESP) (@.1"-.5"w.c.ESP;RISE RANGE: 20-50•F) TAP ADJUST HIGH-STAGE Low-STAGE TAP ADJUST HIGH-STAGE LoW-STAGE RISE CF CFM C CFM Minus 10% 590 404 Minus 10% 861 614 41 Minus 5% 622 427 Minus 5% 909 648 39 A Normal 655 449 A Normal 957 682 37 Plus 5% 688 471 Plus 5% 1,005 716 35 Plus 10% 721 494 Plus 10% 1,053 750 34 Minus 10% 726 512 Minus 10% 953 675 37 Minus 5% 767 541 Minus 5% 1,006 713 35 B Normal 807 569 B Normal 1,059 750 34 Plus 5% 847 597 Plus 5% 1,112 788 32 Plus 10% 888 626 Plus 10% 1,165 825 31 Minus 10% 898 644 Minus 10% 1,040 738 34 Minus 5% 948 680 Minus 5% 1,097 779 32 C Normal 998 716 C Normal 1,155 820 31 Plus 5% 1,048 752 Plus 5% 1,213 861 29 Plus 10% 1,098 788 Plus 10% 1,271 902 28 Minus 10% 1,086 769 Minus 10% 1,126 799 32 Minus 5% 1,147 811 Minus 5% 1,188 844 30 D Normal 1,207 854 D Normal 1,251 888 28 Plus 5% 1,267 897 Plus 5% 1,314 932 27 Plus 10% 1 1,328 1 939 Plus 10% 1 1,376 977 26 NOTES • All furnaces ship as high speed for cooling.Installer must adjust blower speed as needed. • For mostjobs,about 400 CFM per ton when cooling is desirable. • Do not operate above.5"w.c.ESP in heating mode.Operating CFM between.5"and.8""c.is tabulated for cooling purposes only. DC96VC0603BNA DC96VC0603BNA COOLING SPEEDS HEATING SPEED (@.1"-.8"w.c.ESP) (@.1"-.5"w.c.ESP;RISE RANGE:35-65°F) TAP A HIGH-STAGE LoW-STAGE RISE v ADJUST HIG CFM AGE Low-STAGE DJUST Minus 10% 590 390 Minus 10% 844 618 63 Minus 5% 623 411 Minus 5% 891 653 60 A Normal 656 433 A Normal 938 687 57 Plus 5% 689 455 Plus 5% 985 721 54 Plus 10% 722 476 Plus 10% 1,032 756 52 Minus 10% 711 487 Minus 10% 855 676 62 Minus 5% 751 514 Minus 5% 903 713 59 B Normal 790 541 B Normal 950 751 56 Plus 5% 830 568 Plus 5% 998 789 53 Plus 10% 869 595 Plus 10% 1,045 826 51 Minus 10% 875 617 Minus 10% 887 733 60 Minus 5% 923 652 Minus 5% 937 773 s7 C Normal 972 686 C Normal 986 814 5y Plus 5% 1,021 720 Plus 5% 1,035 855 5� Plus 10% 1,069 755 Plus 10% 1,085 895 Minus 10% 1,076 725 Minus 10% 893 787 60 Minus 5% 1,135 766 Minus 5% 942 830 57 D Normal 1,195 806 D Normal 992 874 54 Plus 5% 1,255 846 Plus 5% 1,042 918 51 Plus 10% 1 1,315 1 887 Plus 10% 1 1,091 961 AQ NOTES • All furnaces ship as high speed for cooling_ Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. SS-DC96VC www.daikincomforL.com DC96VCAIRFLOW DATA (CONT.) DC96VC0804CNA DC96VC0804CNA COOLING SPEEDS HEATING SPEED (@ X'-.8"W.C.ESP) (@ X'-.5"w.c.ESP;RISE RANGE: 45-75^F) HIGH-STAGE LoW-STAGE HIGH-STAGE LoW-STAGE Minus 10% 753 500 Minus 10% 1,111 800 n/a Minus 5% 795 528 Minus 5% 1,172 845 n/a A Normal 837 556 A Normal 1,234 889 n/a Plus 5% 879 584 Plus 5% 1,296 933 55 Plus 10% 921 612 Plus 10% 1,357 978 52 Minus 10% 920 643 Minus 10% 1,193 850 n/a Minus 5% 971 678 Minus 5% 1,259 897 n/a B Normal 1,022 714 B Normal 1,32S 944 54 Plus 5% 1,073 750 Plus 5% 1,391 991 51 Plus 10% 1,124 785 Plus 10% 1,458 1,038 49 Minus 10% 1,085 754 Minus 10% 1,298 917 55 Minus 5% 1,146 796 Minus 5% 1,370 968 52 C Normal 1,206 838 C Normal 1,442 1,019 49 Plus 5% 1,266 880 Plus 5% 1,514 1,070 47 Plus 10% 1,327 922 Plus 10% 1,586 1,121 45 Minus 10% 1,328 892 Minus 10% 1,375 961 52 Minus 5% 1,401 941 Minus 5% 1,452 1,015 49 D Normal 1,475 991 D Normal 1,528 1,068 47 Plus 5% 1,549 1,041 Plus 5% 1,604 1,121 n/a Plus 10% 1 1,623 1 1,090 1 Plus 10% 1 1,681 1 1,175 1 n/a NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. DC96VC1005CNA DC96VC1005CNA COOLING SPEEDS HEATING SPEED (@ X'-.8"w.c.ESP) (@ X'-.5"w.c.ESP;RISE RANGE: 45-75'F) TAP ADJUST HIGH-STAGE Low-STAGE TAP ADJUST HIGH-STAGE LoW-STAGE Minus 10% 706 472 Minus 10% 1,583 1,088 56 Minus 5% 745 498 Minus 5% 1,671 1,149 53 A Normal 784 524 A Normal 1,759 1,209 51 Plus 5% 823 550 Plus 5% 1,847 1,269 48 Plus 10% 862 576 Plus 10% 1,935 1,330 46 Minus 10% 970 670 Minus 10% 1,617 1,124 55 Minus 5% 1,024 707 Minus 5% 1,707 1,187 52 B Normal 1,078 744 B Normal 1,797 1,249 49 Plus 5% 1,132 781 Plus 5% 1,887 1,311 47 Plus 10% 1,186 818 1 Plus 10% 1,977 1,374 45 Minus 10% 1,249 834 Minus 10% 1,656 1,149 54 Minus 5% 1,319 881 Minus 5% 1,748 1,213 51 C Normal 1,388 927 C Normal 1,840 1,277 48 Plus 5% 1,457 973 PIus5% 1,932 1,341 46 Plus 10% 1,527 1,020 Plus 10% 2,024 1,405 44 Minus 10% 1,589 1,067 Minus 10% 1,693 1,170 53 Minus 5% 1,678 1,126 Minus 5% 1,787 1,235 50 D Normal 1,766 1,185 D Normal 1,881 1,300 47 Plus 5% 1,854 1,244 Plus 5% 1,975 1,365 45 Plus 10% 1 1,943 1 1,304 Plus 10% 1 2,069 1,430 n/a NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 6 www.daikincomfort.com SS-DC96VC OC96VCAIRFLOW DATA (CONT.) DC96VC1205DNA DC96VC1205DNA COOLING SPEEDS HEATING SPEED (@.1"-.8"W.C.ESP) (@.1"-.5"w.C.ESP;RISE RANGE: 35-65'F) TAP ADJUST HIGH-STAGE Low-STAGE TAs) ADJUST HIGH-STAGE LoW-STAGE RISE Minus 10% 769 486 Minus 10% 1,570 1,156 n/a Minus 5% 811 513 Minus 5% 1,657 1,220 64 A Normal 854 540 A Normal 1,744 1,284 61 Plus 5% 897 567 Plus 5% 1,831 1,348 58 Plus 10% 939 594 Plus 10% 1,918 1,412 56 Minus 10% 1,011 783 Minus 10% 1,644 1,179 65 Minus 5% 1,067 827 Minus 5% 1,736 1,245 61 B Normal 1,123 870 B Normal 1,827 1,310 58 Plus 5% 1,179 914 Plus 5% 1,918 1,376 56 Plus 10% 1,235 957 Plus 10% 2,010 1,441 53 Minus 10% 1,259 900 Minus 10% 1,674 1,215 64 Minus 5% 1,329 950 Minus 5% 1,767 1,283 60 C Normal 1,399 1,000 C Normal 1,860 1,350 57 Plus 5% 1,469 1,050 Plus S% 1,9S3 1,418 55 Plus 10% 1,539 1,100 Plus 10% 2,046 1,485 52 Minus 10% 1,624 1,112 Minus 10% 1,726 1,249 62 Minus 5% 1,714 1,173 Minus 5% 1,822 1,319 59 D Normal 1,804 1,235 D Normal 1,918 1,388 56 Plus 5% 1,894 1,297 Plus 5% 2,014 1,457 53 Plus 10% 1 1,984 1 1,359 1 1 1 Plus 10% 2,110 1,527 1 51 NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. MINIMUM FILTER SIZES 0603BNA 0804CNA00 Filter Size(in')(Qty) (2)10 x 20 or(1)16 x 25(top return) (1)14 x 20(bottom)or(1)20 x 25(top return) Note:Other size filters of equal or greater dimensions maybe used Filters may also be centrally located. SS-DC96VC www.daikincomfort.com 7 WIRING DIAGRAM a I GND TO 115 VAC/10/60 HZ POWER SUPPLY WITH ID SLOWER TWO-STAGE PRESSURE ti OVERCURRENT SWITCH ASSEMBLY r PROTECTION DEVICE S O r L Z Ix WARNING:DISCONNECT HOf OR HIGH PIRE Ox * POWER BEFORE LOW FIRE PRESSU ,'r —N SERVICING.WIRING < SURT^CE PRESSOR SWITCH TO UNIT MUST BE IGNITER ESWTTCH DISCONNECT PROPERLY POLARIZED 2 CIRCUIT AND GROUNDED, CONNECTOR R TO 115VACI 10160 HZ POWER SUPPLY WITH HI I PU OVERCURRENT PROTECTION DEVICE TWO STAGE GND IN GAS VALVE C .2 BR FLAME WARNING: I (WNITERODOERS) SENSOR DISCONNECT POWER PM ! CY GY. BEFORE SERVICING FRONT COVER WIRING TO UNIT Nt., PRESSURE SWITCI I MUST BE PROPERLY O v POLARIZED AND GrxoNro:c l n MANUAL RESET ROLLOUT LIMIT GROUNDED, N 0 CO TROLS(SIN( CONTRO O ,OL IO 40 ABTU) 1 1 1 t' 777SSi SWITCH L J L J -76 AUTO RESET PRIMARY 0 NINGTION DOx C O LIMITCONTROL —PIA INDUCTOR COIL CS (ON SOME MODELS) N d W H INDUCED B.D Y NB xal r DRAFT AIR DD DMB > RD BLOWER 4� �UaATOR = E BK GND ti BURNER COMPARTMENT GND I NEUTRAL SEE NOTE A MOWER COMPARTMENT PU v AUTORESET }7 IR �nJrAIDolrtR O 0 AUXTLCGNi GL `Y YL y C m O A R _ IdYILLN NCyrryW z _ p •AIR CtMGMC � `CLCAN�It vOi u MD rN UIRM. nl it YJW I �O LO NEUTRAL y D W I' Rp1 OU_L 0 Q gMTpR �a ^ a A rLNe[flENbCITI 0 v •IBL $' "ME 11S VAC. MEUTMI _ m D ruw n DVA ;oOM aF® L TN a YRNfB/OM1nA �+ LL_ W f15 QY I I wr Msl�r wsm D�rlLL r'�yV'ARY N cow rvo` Te•voc ca nRna I. rna o v HEnT nr ®�$ BK ¢� Y N n 11 Vtnw tnw R 40 VA r w I p Q T1eMtrWrtt� FA L PK rt arvr F30 BIR oOR Qe ralr F /yH1PU Q V�r I rr C = 0 Nae a ara®1FA"�'nr. ��II u w,on aw.c.. wwny-nlrsar nn.our � Cr.}—I,I I.R CONr.D.. 24 V 3 aPk n G1 lA < �j FUSE trrwarlwe • I rrM G C rR�rDOtrrf�9Y rGrr N I MVII Ir4 rn `¢ ECM MTR l_PI. Daa 3 HARNESS H WH TR r1 {k BKJ 1 OND 41 a R n dK "ec j11 I u: M000R Y PK GND DooR rN anoOio rxul crRciriwTOa ` COMP(LOWER OLWN �,Y Dp a S S - ( PEN WHENH 1DVMttDGONrnw RDDInD Q CO '3 =5 CIRCULATOR BLOWER INDUCTOR COIL DOOR OPEN) a M (ON SOME MODELS) N +' m C � U m r V� d O B0 J C 0 v '3 O E �t t NOTES y O � 1 SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0 Y AMPS C N 2 MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. w +' :F AY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MOST BE REPIACEO, 11 01 C TMIRI-.-PLACES WITH WIRyyqq M11TDAIAL HAVING ATEMPERATURE RATING OF COLOR CODES: EQUIPMENT GND T AT 1.lAOT ram.USE COPPER COWYOtORD ONLY. LOW VOLTAGE(24V) 4 uNlr Musr BE PERMANENTLY GROUNDED ND cDNFDRM To N E c.AND LOCAL caDEs. PK PINK _ ,j s TO RECALL THE LAST B FAULTS,MOST RECENT TO LEAST RECENT.DEPRESS SWITCH SR BROWN LOW VOLTAGE FIELD FIELD GND FOR MORE THAN 2 SECONDS WHILE IN STANDBY INS THERMOSTAT INPUTS) WH WHITE HI VOLTAGE(1 15V) FIELD SPLICE b HUMIDIFIER INSTALLATION OPTIONS:USE HUM TERMINAL TO RUN HUMIDIFIER DURING BL BLUE B HEATTER CALL(COMMUNICATING OR LEGACY MODES)USE HUM-IN ANO'UM OUT GY GRAY HI VOLTAGE FIELD SWITCH TEMP. o-� EGACY MODES ORNINDEPI.=TTLY FgOMCHAT C CALL OMMUNICATING MODE OR RD RED (TEMP.) e (COMMUNICATING MODE ONLY- JUNCTION SETUP IS DON WITHIN COMMUNICATING THERMOSTAT) YL YELLOW IGNITERr OR ORANGE TERMINAL -0- c PU PURPLE INTERNAL TO SWITCH(PRESS.) - p T GIN GREEN INTEGRATED CONTROL OVERCURRENT c BK BLACK PLUG CONNECTION -C:=F- PROT.DEVICE 0140F0200666-A Our continuing commitment to quality products may mean a change in specifications without notice. 02018OA/K/NMANUFACTUR/NO COMPANY.L..P a Houston,Texas 8 www.daikincomfort.com SS-DC96VC d5 NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ ]DO NOT OCCUPY L-1 APPROVED PERMIT#: LOT#: DATE: is f I JOB ADDRESS: TYPE OF INSPECTION: ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK:MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. Cl CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE (PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION l� THEACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DAT / v o� 1 BUILDING DEPT. _ Cl PLANNING WEPT. CITY OF ARLINGTON • RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 7726 Inverness Dr. Arlington, WA 98223 Project Description:Replace existing furnace with new Owner: Terry L and Maralyn Johnson Address. 7726 Inverness Dr. City. Arlington State.WA Zip Code: 98223 Phone: 4255850659 Email:pilchuckheating@pilchuckheating.com Applicant: Pilchuck Heating LLC Address: 1429 Ave. D #224 City: Snohomish State.WA Zip Code: 98290 Phone. 4255015480 Email: jefft@pilchuckheating.com CONTRACTOR INFORMATION Contractor Name:Pllchuck Heating LLC Address: 1429 Ave. D #224 City: Snohomish State.WA Zip Code: 98290 License Number: PILCHHL823LN Expiration: 06/15/2020 Phone: 4255015480 Email:jefft@pilchuckheating.com STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #DM96VC0603B AFUE96% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: [El Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: 13b"a92O�db81'b61e6' Date: 04/25/2019 Applicant Printed Name: Jeffrey Talbert I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 d I NOTICE TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ -p0 NOT OCCUPY 0 APPROVED PERMIT#: LOT#:' DATE: Li ( I l JOB ADDRESS: f TYPE OF INSPECTION: ,, ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK:MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. I 1 ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. t. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. j ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION i THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATWI A BUILDING"DEPT. Cl PLANNING DEPT. CITY OF ARLINGTON (40 '? CITY OF ARLINGTON 238 N. OLYMPIC AVE -ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:7726 Inverness Dr. Permit#:2525 Parcel#:00865900007700 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:JOHNSON TERRY L/MARALYNN Name:Pilchuck Heating,LLC Name:Pilchuck Heating Address:7726 INVERNESS DR Address:1429 Ave.D Address: 1429 Avenue D,#224 City,State Zip:ARLINGTON,WA 98223-5047 City,State Zip:Snohomish,WA 98290 City,State Zip:Snohomish,WA 98290 Phone: Phone:425-501-5480 Phone:425-501-5480 LIC: EXP: MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Pilchuck Heating Name: Address: 1429 Avenue D Address: City,State,Zip:Snohomish,WA 98290 City,State,Zip: Phone:425-501-5480 Phone: LIC#:PILCHH*874PW EXP: 10/29/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1I0/IRC110. SALES TAX NOTICE.Sales tax relating to construction and construction materials in the City of Arlington is b reported on our sales tax retu form and coded City of Arlington#3101. y Signature Print Name Date (� By are CONDITIONS Adhere to approved appliance. Call for final inspection THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 4/25/2019 Furnace $25.00 4/25/2019 Mechanical Permit Base Fee $25.00 4/25/2019 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon FDAIKIN DC96VC COMFORTNETTM-COMPATIBLE TWO-STAGE, VARIABLE-SPEED ECM-BASED GAS FURNACE UP To 96%AFUE HEATING INPUT.' 40,000-120,000 BTU/H ■ Contents Nomenclature........................................2 Accessories............................................2 Product Specifications...........................3 Dimensions............................................4 Airflow Specifications............................5 Wiring Diagram......................................8 EN ComfortNEt � srsrE�v ■ Standard Features ■ Cabinet Features • ComfortNet`"communicating system compatible • Designed for multi-position installa- • Heavy-duty stainless-steel tubular heat exchanger lion —downflow, horizontal left or right • Stainless-steel secondary heat exchanger • Certified for direct vent(2-pipe)or • Two-stage gas valve provides quiet, non-direct vent(1-pipe) economical heating • Convenient left or right connection • Durable Silicon Nitride igniter for gas and electrical service • Quiet two-speed induced draft blower • Cabinet air leakage(QLeak)<_2% • Utilizes ComfortNet'"communicating,two- • Heavy-gauge steel cabinet with durable finish stage or single-stage thermostats • Fully insulated heat exchanger • Self-diagnostic control board with constant memory and blower section fault code history output to a dual 7-segment display • Airtight solid bottom or side return with • Color-coded low-voltage terminals with provi- easy-cut tabs for effortless removal sions for electronic air cleaner and humidifier in bottom air-inlet applications • Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand • Multiple continuous fan speed options offer quiet air circulation • Auto-Comfort and enhanced dehumidification modes available � � � � I US • All models comply with California 40 ng/J Intertek Low NOx emissions standard • For installation in California's South Coast Air Quality LManagement District(SCAQMD)only:This furnace does not meet the SCAQMD Rule 111114 ng/J NOx emission limit,and thus is subject to a mitigation fee of up to$450. *Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the Lifetime Heat Exchanger Limited This furnace is not eligible for the SCAQMD Clean Air Warranty(good for as long as you own your home),the 12-Year Unit Replacement Limited Warranty and Furnace Rebate Pro ram:WWW.CIeanAlrFU rnace Rebate.COm. the 12-Year Parts Limited Warranty,online registration must be completed with in 60 days of instal ladon. g Additional requirements for annual maintenance are required forthe Unit Replacement Limited Warranty. Online registration and some of the additional requirements are not required in California or Quebec. SS-DC96VC www.daikincomfort.com 9/18 Supersedes 4/18 NOMENCLATURE D C 96 V C 060 3 B N A A 1 2 3,4 5 6 7,8,9 10 11 12 13 14 LBrand Minor Revision D-Daikin Brand A-Initial Release B-1st Revision Configuration M-Upflow/Horizontal Major Revision C-Downflow/Horizontal A-Initial Release B-1st Revision AFUE 97—97-98%AFUE 92-92%AFUE NOx 96-96%AFUE N- Low Nox(40ng/J) Gas Valve Cabinet Width M-Modulating H-Convertible Two-Stage B-17Y2" V-Two Stage S-Single Stage C-21" D-24%" Motor C-Variable Speed ECM/ComfortNet Maximum CFM E-Multi-Speed ECM S-Multi-Speed PSC 2- 800 CFM 3-1200CFM MBTU/h 4-1600 CFM 040-40,000 BTU/h 100-100,000 BTU/h 5-2000 CFM 060-60,000 BTU/h 120-120,000 BTU/h 080-80,000 BTU/h ACCESSORIES CTK04 ComfortNet-Compatible Control V V V V V CVENT-2 Concentric Vent Kit(2") V V V V V CVENT-3 Concentric Vent Kit(3") V d V d d CFSB17 Downflow Sub-Base 17.5" V V --- -- --- CFSB21 Downflow Sub-Base 21" --- --- V V --- CFSB24 Downflow Sub-Base 24" --- --- --- --- V RF000142 Drain Kit-Horizontal Left Vertical Flue --- --- --- --- --- EFR02 External Filter Rack with 16"x25"Permanent Filter V V V --- --- 0170K00000S Flush Mount Vent Kit-3"or 2" V d d V V 0170K00001S Flush Mount Vent Kit-2" V V V V d AFE18-60A Fossil Fuel(Dual Fuel)Kit V V V V HASFK High-Altitude Natural Gas Kit HASFK-1 HASFK-1 HASFK-2 HASFK-3 HASFK-3 HASFK High-Altitude LP Gas Kit HASFK-1 HASFK-1 HASFK-2 HASFK-2 HASFK-3 LPLP03 Low LP Gas Pressure Switch V V V V V LPM-08 LP Conversion Kits V V V V 2 www.daikincomfort.com SS-DC96VC PRODUCT SPECIFICATIONS 0403BNA 0603BNA 0804CNA 1005CNA Heating Data High Fire Input' 40,000 60,000 80,000 100,000 120,000 High Fire Output' 38,400 57,600 76,800 96,000 115,200 Low-Fire Steady-State Input' 28,000 42,000 56,000 70,000 84,000 Low-Fire Steady-State Output' 26,880 40,320 53,760 67,200 80,640 AFUE2 96 96 96 96 96 Temperature Rise Range(°F) 20-50 35-65 25-55 45-75 35-65 Vent Diameter3 2"-3" 2"-3" 2"-3" 2"-3" 2"-3" No.of Burners 2 3 4 5 6 Circulator Blower Available AC@0.5"ESP 1.5-3 1.5-3 1.5-4 2-5 2-5 Size (D x W) 10"x 8" 11"x 8" 11"x 10" 11"x 10" 11"x 11" Horsepower @ 1075 RPM %Z %Z % 1 1 Speed VS ECM VS ECM VS ECM VS ECM VS ECM Electrical Data Min.Circuit Ampacity^ 7.8 7.8 10.6 14.4 14.4 Max.Overcurrent Device(amps)' 15 15 15 20 20 Shipping Weight(lbs) 116 119 143 145 158 Natural Gas BTU/h 2 DOE AFUE based upon Isolated Combustion System(ICS) Installer must supply one or two PVC pipes:one for combustion air(optional)and one for the flue outlet(required).Vent pipe must be either 2"or 3"in diameter,depending upon furnace input,number of elbows,length of run and installation(1 or 2 pipes).The optional Combus- tion Air Pipe is dependent on installation/code requirements and must be 2"or 3"diameter PVC. 4 Minimum Circuit Ampacity=(1.25 x Circulator Blower Amps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply. • Gas Service Connection%"FPT • Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. • For bottom return:Failure to unfold flanges may reduce airflow by up to 18%.This could result in performance and noise issues. • For servicing or cleaning,a 24"front clearance is required.Unit connections(electrical,flue and drain) may necessitate greater clearances than the minimum clearances listed above.In all cases,accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. SS-DC96VC www.daikincomfort.com 3 DC96VC DIMENSIONS A 6% B 2% lx C_��j-*-1% 2% 1R'/. 1%+1 23— lx Alternate Vent/ Flue Location 3 111,Y: Low-Voltage Electrical Outlet Low-Voltage Electrical Outlet 14 Alternate Gas E Supply Location Alternate Gas Supply High-Voltage Location Electrical Outlet 34% 25x zsx 0lax lax lax llx O llx 6x 6x 4% Left-Side Exterior High-Voltage Drain Trap Holes 18x D Electrical Outlet Standard Drain Trap 2 Unfolded Flanges 2x Unfolded Flanges Connection'b"PVC 2py, 3Y= E 2 28% Folded Flanges Folded Flanges 2% Left-Side View Right-Side View Front View Right Side Exterior Air Drain Trap Holes Air Discharge Discharge AIR DISCHARGE DC96VC0403 BNA 17Y2" 14W 14" 14%z" 16" DC96VC0603 BNA 17Y2" 14W 14" 14%z" 16" DC96VC0804CNA 21" 18%" 17%" 18" 19%" DC96VC1005CNA 21" 18%" 17%" 18" 19%" DC96VC1205DNA 24%" 21W 21" 21%" 23" MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION SIDES REAR FRONT BOTTOM FLUE Top Downflow 0" 0" 3" NC 0" 1" Horizontal 6" 0" T. C 0" 6" C=If placed on combustible floor,the floor MUST be wood ONLY. NC=For installation on non-combustible floors only.A combustible floor sub-base must be used for installations on combustible flooring. 4 www.daikincomfort.com SS-DC96VC DC96VC AIRFLOW DATA DC96VC0403BNA DC96VC0403BNA COOLING SPEEDS HEATING SPEED (@ X'-.8"W.C.ESP) (@.1"-.5"w.c.ESP;RISE RANGE: 20-50•F) TAP ADJUST HIGH-STAGE Low-STAG E TAP ADJUST HIGH-STAGE Low-STAG E RISE CIF CFM C CFM Minus 10% 590 404 Minus 10% 861 614 41 Minus 5% 622 427 Minus 5% 909 648 39 A Normal 655 449 A Normal 957 682 37 Plus 5% 688 471 Plus 5% 1,005 716 35 Plus 10% 721 494 Plus 10% 1,053 750 34 Minus 10% 726 512 Minus 10% 953 675 37 Minus 5% 767 541 Minus 5% 1,006 713 35 B Normal 807 569 B Normal 1,059 750 34 Plus 5% 847 597 Plus 5% 1,112 788 32 Plus 10% 888 626 Plus 10% 1,165 825 31 Minus 10% 898 644 Minus 10% 1,040 738 34 Minus 5% 948 680 Minus 5% 1,097 779 32 C Normal 998 716 C Normal 1,155 820 31 Plus 5% 1,048 752 Plus 5% 1,213 861 29 Plus 10% 1,098 788 Plus 10% 1,271 902 28 Minus 10% 1,086 769 Minus 10% 1,126 799 32 Minus 5% 1,147 811 Minus 5% 1,188 844 30 D Normal 1,207 854 D Normal 1,251 888 28 Plus 5% 1,267 897 Plus 5% 1,314 932 27 Plus 10% 1,328 939 Plus 10% 1,376 977 26 NOTES • All furnaces ship as high speed for cooling.Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable. • Do not operate above.5"w.c.ESP in heating mode.Operating CFM between.5"and.8"w.c.is tabulated for cooling purposes only. DC96VC0603BNA DC96VC0603BNA COOLING SPEEDS HEATING SPEED (@.1"-.8"w.c.ESP) (@.1"-.5"w.c.ESP;RISE RANGE: 35-65•F) TAP ADJUST HIGH-STAGE LOW-STAG E TAP ADJUST HIGH-STAGE LOW-STAG E RISE CIF CFM C CFM Minus 10% 590 390 Minus 10% 844 618 63 Minus 5% 623 411 Minus 5% 891 653 60 A Normal 656 433 A Normal 938 687 57 Plus 5% 689 455 Plus 5% 985 721 54 Plus 10% 722 476 Plus 10% 1,032 756 52 Minus 10% 711 487 Minus 10% 855 676 62 Minus 5% 751 514 Minus 5% 903 713 59 B Normal 790 541 B Normal 950 751 56 Plus 5% 830 568 Plus 5% 998 789 53 Plus 10% 869 595 Plus 10% 1,045 826 51 Minus 10% 875 617 Minus 10% 887 733 60 Minus 5% 923 652 Minus 5% 937 773 57 C Normal 972 686 C Normal 986 814 54 Plus 5% 1,021 720 Plus 5% 1,035 855 52 Plus 10% 1,069 755 Plus 10% 1,085 895 49 Minus 10% 1,076 725 Minus 10% 893 787 60 Minus 5% 1,135 766 Minus 5% 942 830 57 D Normal 1,195 806 D Normal 992 874 54 Plus 5% 1,255 846 Plus 5% 1,042 918 51 Plus 10% 1,315 887 Plus 10% 1,091 961 49 NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. SS-DC96VC www.daikincomfort.com 5 DC96VC AIRFLOW DATA (CONT.) DC96VC0804CNA DC96VC0804CNA COOLING SPEEDS HEATING SPEED (@.1"-.8"w.c.ESP) (@ X'-.5"w.c.ESP;RISE RANGE: 45-75•F) TAP ADJUST HIGH-STAGE LoW-STAGE TAP ADJUST HIGH-STAGE LoW-STAGE RISE C CFM C CFM Minus 10% 753 500 Minus 10% 1,111 800 n/a Minus 5% 795 528 Minus 5% 1,172 845 n/a A Normal 837 556 A Normal 1,234 889 n/a Plus 5% 879 584 Plus 5% 1,296 933 55 Plus 10% 921 612 Plus 10% 1,357 978 52 Minus 10% 920 643 Minus 10% 1,193 850 n/a Minus 5% 971 678 Minus 5% 1,259 897 n/a B Normal 1,022 714 B Normal 1,325 944 54 Plus 5% 1,073 750 Plus 5% 1,391 991 51 Plus 10% 1,124 785 Plus 10% 1,458 1,038 49 Minus 10% 1,085 754 Minus 10% 1,298 917 55 Minus 5% 1,146 796 Minus 5% 1,370 968 52 C Normal 1,206 838 C Normal 1,442 1,019 49 Plus 5% 1,266 880 Plus 5% 1,514 1,070 47 Plus 10% 1,327 922 Plus 10% 1,586 1,121 45 Minus 10% 1,328 892 Minus 10% 1,375 961 52 Minus 5% 1,401 941 Minus 5% 1,452 1,015 49 D Normal 1,475 991 D Normal 1,528 1,068 47 Plus 5% 1,549 1,041 Plus 5% 1,604 1,121 n/a Plus 10% 1,623 1,090 Plus 10% 1,681 1,175 n/a NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. DC96VC1005CNA DC96VC1005CNA COOLING SPEEDS HEATING SPEED (@.1"-.8"w.c.ESP) (@.1"-.5"w.c.ESP;RISE RANGE: 45-75•F) TAP ADJUST HIGH-STAGE LoW-STAGE TAP ADJUST HIGH-STAGE LoW-STAGE RISE C CFM C CFM Minus 10% 706 472 Minus 10% 1,583 1,088 56 Minus 5% 745 498 Minus 5% 1,671 1,149 53 A Normal 784 524 A Normal 1,759 1,209 51 Plus 5% 823 550 Plus 5% 1,847 1,269 48 Plus 10% 862 576 Plus 10% 1,935 1,330 46 Minus 10% 970 670 Minus 10% 1,617 1,124 55 Minus 5% 1,024 707 Minus 5% 1,707 1,187 52 B Normal 1,078 744 B Normal 1,797 1,249 49 Plus 5% 1,132 781 Plus 5% 1,887 1,311 47 Plus 10% 1,186 818 Plus 10% 1,977 1,374 45 Minus 10% 1,249 834 Minus 10% 1,656 1,149 54 Minus 5% 1,319 881 Minus 5% 1,748 1,213 51 C Normal 1,388 927 C Normal 1,840 1,277 48 Plus 5% 1,457 973 Plus 5% 1,932 1,341 46 Plus 10% 1,527 1,020 Plus 10% 2,024 1,405 44 Minus 10% 1,589 1,067 Minus 10% 1,693 1,170 53 Minus 5% 1,678 1,126 Minus 5% 1,787 1,235 50 D Normal 1,766 1,185 D Normal 1,881 1,300 47 Plus 5% 1,854 1,244 Plus 5% 1,975 1,365 45 Plus 10% 1,943 1,304 Plus 10% 2,069 1,430 n/a NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 6 www.daikincomfort.com SS-DC96VC DC96VC AIRFLOW DATA (CONT.) DC96VC1205DNA DC96VC1205DNA COOLING SPEEDS HEATING SPEED (@.1"-.8"W.C.ESP) (@.1"-.5"W.C.ESP;RISE RANGE: 35-65•F) TAP ADJUST HIGH-STAGE LoW-STAGE TAP ADJUST HIGH-STAGE LoW-STAGE RISE Minus 10% 769 486 Minus 10% 1,570 1,156 n/a Minus 5% 811 513 Minus 5% 1,657 1,220 64 A Normal 854 540 A Normal 1,744 1,284 61 Plus 5% 897 567 Plus 5% 1,831 1,348 58 Plus 10% 939 594 Plus 10% 1,918 1,412 56 Minus 10% 1,011 783 Minus 10% 1,644 1,179 65 Minus 5% 1,067 827 Minus 5% 1,736 1,245 61 B Normal 1,123 870 B Normal 1,827 1,310 58 Plus 5% 1,179 914 Plus 5% 1,918 1,376 56 Plus 10% 1,235 957 Plus 10% 2,010 1,441 53 Minus 10% 1,259 900 Minus 10% 1,674 1,215 64 Minus 5% 1,329 950 Minus 5% 1,767 1,283 60 C Normal 1,399 1,000 C Normal 1,860 1,350 57 Plus 5% 1,469 1,050 Plus 5% 1,953 1,418 55 Plus 10% 1,539 1,100 Plus 10% 2,046 1,485 52 Minus 10% 1,624 1,112 Minus 10% 1,726 1,249 62 Minus 5% 1,714 1,173 Minus 5% 1,822 1,319 59 D Normal 1,804 1,235 D Normal 1,918 1,388 56 Plus 5% 1,894 1,297 Plus 5% 2,014 1,457 53 Plus 10% 1,984 1,359 Plus 10% 2,110 1,527 51 NOTES • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs,about 400 CFM per ton when cooling is desirable • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. MINIMUM FILTER SIZES Filter Size(inz)(Qty) I _F(2)10 x 20 or(1)16 x 25(top return) (1)14 x 20(bottom)or (1)20 x 25(top return) Note:Other size filters of equal or greater dimensions may be used.Filters may also be centrally located. SS-DC96VC www.daikincomfort.com 7 WIRING DIAGRAM GND TO 115 VAC/1 0/60 HZ C �r r POWERSUPPLV WITH ID BLOWER TWO STAGE PRESSURE n y OVERCURRENT SWITCH ASSEMBLY J r PROTECTION DEVICE L c A DO BK WARN I NG:DISCONNECT __L,e HIGH FIRE O POWER BEFORE HOT OR PRESSUR x I � �N SERVICING.WIRING < SURFACE PRESSUR SWITCH H TO UNIT MUST BE IGNITER E SWITCH '� DISCONNECT PROPERLY POLARIZED 2 CIRCUIT AND GROUNDED. CONNECTOR OR TO 115VAC/10/60 HZ POWER SUPPLY WITH HI a PU OVERCURRENT PROTECTION DEVICE \• TWO STAGE C 2 BR FLAMEGINO .\ GAS VALVE WARNING: (WHITERODGERS) SENSOR DISCONNECT POWER PM 1 GV GY BEFORE SERVICING. FRONT COVER WIRING TO UNIT 3 PRESSURE SWITCH MUST BE PROPERLY O w POLARIZED AND .- GROUNDED. DISCONNECT MANUAL RESET ROLLOUT LIMIT N O CONTROLS(SINGLE CONTROL ON O .� 40 kBTU� D O BL PK OR = DOOR A W N SWITCH AUTO RESET PRIMARY A JUNCTION... �C c LIMIT CONTROL O O PU C INDUCTOR COIL 11 Z (ON SOME MODELS) N INDUCED O GND rfr� 3 WH INDOOR DRAFT AIR 2 RD BLOWER � CIRCULATOR O 1 BK Z BLWR = E GND N BURNER COMPARTMENT GND LINE SEE NOTE 6 NEUTRAL C = BLOWER COMPARTMENT PD m UM-OUT HUMIDIFIER m 0 p LIMITAUXI ARY YL �n �UMIDIFI�R EUTRAL D_ .Zl LIMIT CONTROL HUM 2 U N i 'ELECTRONIC, AIRCLEAN=R N U IND HI @ F7�I BID LWR U�U II.n O O E $;I IND LO NEUTRAL $ O W HOT SURFACE O �_ IGNITER W"B A O O III$. FLAME SENSOR D- v uN LBL LINE 115VAC NEUTRAL — 3 E r` COOLAIm 40 VA li .4 BL FUSE3A TH 4 TRANSFORMER r, r. TRIM - GY 24 ocl LIMIT RESET AU UARY COOL ° C L m BK m o oO v A AcoN N EL D p PU O HEAT AF LE� " 40 VA NLE�N A TRANSFORMERI]] m I1 I PSO] y —GI E IM ENn o PRESS. ±21 YL PK s oNT rA m o z MK24 cHBR OR 0 TOFFDT 07, NOu NO 3 H/PU T C 2 O 2 OK VC c O PRESS. II PR LHE s1s13 4. 'ES swn cH MANUAL vALLPHoVMIFu r E® IC LIMIT CONTROLS s ® E A ZV 243AVj FUSE SSU11 SWITCH ECM MTR IGND s HARNESS MIWH4—WH ITR(1 DO a BK BK TO I GND(4) R s s BK +vgc ry> 4 PKAIR I RX 2) INDOOR 3 G TO CIRCULATOR 1 PK BLOWER MICRO ITX(3 BLWR TL b0 COMPARTMENT +' DOOR SWITCH 3 2 a (OPEN WHEN INTEGRAiEO CONTROL MODULE Q O3 CIRCULATOR BLOWER INDUCTOR COIL DOOR OPEN) aj (ON SOME MODELS) 00 E C @-O N O L (0 U� Q O O C t+ v :3 0 9 E H N N Y Y NOTES: O O 1.SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.]AMPS. C 2.MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. w :L 3.IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, i1 ITMUSTBEREPLACEDWITH WIRING MATERIALHAVINGATEMPERATURE RATINGOF COLOR CODES: EQUIPMENT GND rh AT LEAST I Or-USE COPPER CONDUCTORS ONLY. LOW VOLTAGE(24V) 4.UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C.AND LOCAL CODES. PK PINK 5.TO RECALL THE LAST 6 FAULTS,MOST RECENT TO LEAST RECENT,DEPRESS SWITCH BR BROWN LOW VOLTAGE FIELD FIELD GND FOR MO RE THAN 2 SECONDS WHILE IN STANDBY(NO THERMOSTAT IN PUTS) WH WHITE HI VOLTAGE(1 15V) FIELD SPLICE b 6.HUMIDIFIER INSTALLATION OPTIONS:USE HUM TERMINAL TO RUN HUMIDIFIER DURING BL BLUE HEAT CALL(COMMUNICATING OR LEGACY MODES).USE HUM-IN AND HUM-OUT GY GRAY HI VOLTAGE FIELD SWITCH TEMP. TERMINALS TO RUN HUMIDIFIER DURING HEAT CALL(COMMUNICATING MODE OR (TEMP.) LEGACY MODE)OR INDEPENDENTLY FROM HEAT CALL(COMMUNICATING MODE ONLY- RD RED JUNCTION SETUP IS DONE WITHIN COMMUNICATING THERMOSTAT) YL YELLOW IGNITER WL.r OR ORANGE TERMINAL � t PU PURPLE INTERNALTO SWITCH(PRESS.) -E�N"Xt IC GN GREEN INTEGRATED CONTROL OVERCURRENT �BK BLACK PLUG CONNECTION PROT.DEVICE 0140F02006-A Our continuing commitment to quality products may mean a change in specifications without notice. ©2018 DA/K/NMANUFACTUR/NGCOMPANY..L.P . Houston,Texas 8 www.daikincomfort.com SS-DC96VC Permit#: 2525 Permit Date: 04/25/19 Permit Type: RESIDENTIAL MECHANICAL Project Name: Johnson Applicant Name: Pilchuck Heating, LLC Applicant Address: 1429 Ave. D Applicant, City, State, Zip: Snohomish, WA 98290 Contact: Phone: 425-501-5480 Email:jefft@pilchuckheating.com Scope of Work: Replace existing furnace Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00865900007700 7726 INVERNESS DR JOHNSON TERRY 111 Single Family L/MARALYNN Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# Pilchuck Heating Jeff Talbert 425-501-5480 1429 Avenue D, CONSTRUCTION COA 604 257 098 #224 CONTRACTOR Pilchuck Heating Jeff Talbert 425-501-5480 1429 Avenue D, CONSTRUCTION ConstructionPILCHHL823LN #224 CONTRACTOR Contractor Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 04/30/2019 R04.PLUMBING 04/30/2019 BUILDING Approved GROUNDWORK Fees Fee Description Notes Amount Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Total $75.00 Attached Letters Date Letter Description 04/25/2019 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 04/25/2019 Danielle Shadley 75037563 iTransact CC $75.00 Outstanding Balance $0.00 Uploaded Files Date File Name 09/22/2021 9741605-2525 IC 4.30.2019 Final.pdf 04/25/2019 4808198-2525 Apnlication.pdf 04/25/2019 4808199-2525 Specs.pdf