Loading...
HomeMy WebLinkAbout18406 Ballantrae Dr_BLD20110221_2025 or-% BUILDING INSPECTION REPORT Get Y o� Permit No. l/ J 2 2 1 Address: <<nrGII�p� Contractor: Owner: Date: APPROVAL ri PARTIAL APPROVAL VIOLATION ® CORRECTION REQUEST Corrections listed below MUST BE MADE before work can be approved Please contact inspector Was not able to perform inspection Call 360-435-0674 FOR RE-INSPECTION by 5:00 pm the day before Inspector: kld& Date:_&Ak/ _. ® Under-floor ® Framing ® Gas Piping ® Footing ® Drywall, nailing ® Consultation ® Foundation ®Shear Nailing ® Groundwork ® Mechanical ® Grid ® Struct. Slab ® Wood Stove ® Rough-in ® Final ® Masonry ® Drainage ® Insulation /ffOther: CITY OF ARLINGTON 238 N. OLYMPIC AVE.-ARLINGTON,WA. 98223 PHONE: (360)403-3421 BUILDING PERMIT Address: 18406 BALLANTRAE DR,ARLINGTON Permit#:BLD20110221 Parcel#: 00865900008800 Valuation:$0.00 OWNER APPLICANT CONTRACTOR MICHAEL&SOPRINA STARMER MICHAEL&SOPRINA STARMER MICHAEL&SOPRINA STARMER 18406 Ballantrae Drive 18406 Ballantrae Drive 18406 Ballantrae Drive Arlington,WA 98223 Arlington,WA 98223 Arlington,WA 98223 Lie#: Exp: 'PLUMBING CONTRACTOR MECHANICAL CONTRACTOR MICHAEL&SOPRINA STARMER 18406 Ballantrae Drive Arlington,WA 98223 Lie#: Exp: Lie#: Exp: JOB DESCRIPTION Install Quadra Fire Pellet Stove PERMIT TYPE: Residential PERMIT GROUP: Chimney/Fireplace/Hearth STORIES: 0 CONST TYPE: DWELLING UNITS: 0 OCC GROUP: CODE: OCC LOAD: 'iE;i�tithi>t'r'APfiROy�AL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY,NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED.IBC 10/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return forn and coded City of Arlin t it#310 . AV `\ /rr ignature Print Name ate leased By Date ARCHIVE = APPLICANT ASSESSOR Q OTHER 1 BLD20110221 CONDITIONS THIS PERMIT AUTHORIZES ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY.ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. • None PERMIT FEES Date [)escrihtion Fee Amount Paid Balance Due 11/7/2011 Mechanical Permit Fee $60.00 $0.00 $60.00 Total Due: $60.00 $0.00 $60.00 CALL FOR INSPECTIONS BUILDING/ENGINEERING/PARKS/UTILITIES/FINAL(360)435-0674 FIRE(360)403-3607 When calling for an inspection please leave the following information: Permit Number,Job Site Address,Type of Inspection being requested,Contact Name and Phone Number,Date Prefereed,and whether you prefer morning or afternoon. • None I IIIJ,�D/? � /RE CONTACT INFORMATION• N COPY Hearth & Home Technologies 1445 North Highway' Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer logo onto www.cluadrafire.com CAUTION DO NOT DISCARD THIS MANUAL _ Important operating and • Read,understand and • Leave this manual with ®Is0� maintenance ins,ruc- follow these instruc- party responsible for use q o� tions included. tions for safe installa- and operation. 4 tion and operation. We recommend that you record the following pertinent information for your SANTA FE PELLET STOVE Date purchased/installed: CITY OF A BUILDING DEPARTMENT Serial Number: Locat n on appliance: Dealership purchased from: - --- ��al r phone: Notes: DATE BY` rf;oFri_�o UNLESS APPROVED BY THE This product may be covered by one or more of the following patents: (United States)4593510,4686807,4766876,4793322,4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860,6688302B2,6715724B2,6729551,6736133,6748940,6748942,6769426,6774802,6796302,6840261,6848441,6863064, 6$66205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia)780250, 780403, 1418504 or other U.S.and foreign patents pending. HEARTHe'-HOME technologies Page 52 7050-128B September 3, 2009 16-0 BUILDING PERMIT PERMIT#: BLD20110221 OWNER: STARMER,MICHAEL&SOPRINA STATUS:APPLIED ADDRESS: 18406 BALLANTRAE DR,ARLINGT... BALANCE:$0.00 ISSUED: CREATED: 11/7/2011 `' j� SCREENS: Select Screen... FUNCTIONS: SelectPermit Function... CHIMNEY/FIREPLACE/H EARTH REVIEWS PRINT ADD NEW SUMMARY REVI.. DESCRIPTION ASSIGNE... DUE DATE I LAST I (#) IRE Q?DO...I ASSIGN I REMOVE 1002 P-Engineering I LPETER... 11/14/2011: 0 ! Y N Assign Remove 2000 C-Building I CYOUNG 11/14/2011 0 Y N Assign Remove l http://coaweb2.arlington.local/PermitTrax/Module_Permits/Permits_Pennit/Pernlit.Revie... 11/7/2011 RESIDENTIAL MECHANICAL PERMIT APPLICATION Department of Community Development City of Arlington•238 N Olympic Ave. •Arlington,WA 98223 • Phone(360)403 3551 • FAX(360)403 3418 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2) SETS OF CONSTRUCTION DRAWINGS, TWO(2)SETS OF SPECIFICATION SHEETS AND TWO(2)SETS OF WASHINGTON STATE ENERGY CODE(if applicable), Project Valuation: ' Q ProjectAddr -s: Parcel ID#: V[/V c� Lot#: Subdivision: ' Project Description: aw ) 1 Owner:S�9_► r— 1 I Phone Number: Address: jQ qn(Q &l6YtA112 City: (a 12% l K21 C51OAtate: 01� Zip Code:9 Contact Person: 0,130( Q Phone Number: Cell Phone: Fax: E-mail: Address: City: State: Zip Code: Please List quantity of fixtures below: FURNACE UP TO 100K BTU CLOTHES DRYER GAS OUTLETS FURNACE OVER 100K FLOOR FURNACE SUSPENDED HTR/UNIT HTR BOILER UP TO 3 HP APPLIANCE REPAIRS SOLID-FUEL APPLIANCE BOILER UP TO 4-15 HP AIR HANDLING UP TO 10K CFM FIREPLACE INSERT BOILER UP TO 16-30 HP AIR HANDLING OVER 10K CFM VENTILATION SYSTEM HEAT PUMP VENTILATION FANS OTHER VENT HOOD DOMESTIC INCINERATOR ALL OTHER UNITS FREESTANDING STOVE Contractor: ®U)YVY Phone Number: Address: City: State: Zip Code: Contractor's License Number: Expiration I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above- described property will be in accord nce with the laws, rules and regulation of the State of Washington. Applicants no atu Date Print Applicants Name C L���C��r CITY OF ARLINGTON FOR STA U w . a A Engineering De 3t. Permit# Accepted-By m�Received Receipt I late Received DATE It / it NO F " _iC:S ALJ i HONIZ_ED 2010 CJY UNLESS APPROVED BY THE BUILDING INSPECTOR BLD20110221 (PT-LIVE) - PermitTrax by Bitco Software Page 1 of 1 BUILDING PERMIT PERMIT#: BLD20110221 \ OWNER: STARMER, MICHAEL&SOPRINA STATUS:APPLIED ADDRESS: 18406 BALLANTRAE DR,ARLINGT... BALANCE: $0.00 -. 1. ISSUED: CREATED: 11/7/2011 SCREENS: Select Screen... FUNCTIONS: Select Permit Function... C H I M N EY/FI R E P LAC E/H EARTH REVIEWS PRINT ADD NEW SUMMARY REVI.. DESCRIPTION JASSIGNE...' DUE DATE j LAST (#) jREQ?DO... ASSIGN I REMOVE 1002 P-Engineering I LPETER. . 11/14/2011 0 Y N Assign Remove 2000 C-Building I CYOUNG 11/14/2011 0 Y N Assign Remove http://coaweb2.arlington.local/PermitTrax/Module Permits/Permits Permit/Permit Revie... 11/7/2011 \J (IADRA - IRE SANTA FE PELLET STOVE \;_ Testod and PoRland Owner's Manual` Liatod by Oregon USA c us Installation and Operatio `� OMNI-Test Laboratories,Inc. Model: DECEIVE SANTAFE-MBK NOV 0 7 2011 T o \ COA Engineeringik ? Feuer woiltawurot M r•.:..o CAUTION DO NOT DISCARD THIS MANUAL 40, Important operating and Read,understand and Leave this manual with OAS maintenance instruc- follow these instruc- party responsible for use C1 0 ntions included. tions for safe installa- and operation. �Q tion and operation. ® WARNING A WARNING Please read this entire manual I efore installation and use of this HOT SURFACES! pellet fuel-burning room heater. Failure to follow these instructions Glass and other surfaces are hot during operation AND could result in property damage, cool down. bodily injury or even death. lit • Do not store or use gasoline or other flam- Hot glass will cause burns. mable vapors and liquids in the vicinity of this • Do not touch glass until it is cooled or any other appliance. • NEVER allow children to touch glass • Keep childre away • Do not overtire - If any external part starts to CAREFULLY SUPERVISE children in same room glow, you are overfiring. Reduce feed rate. as fireplace. Overfiring will void your warranty. Alert children and adults to hazards of high • Comply with all minimum clearances to com- temperatures. bustibles as specified. Failure to comply may High temperatures may ignite clothing or other flammable materials. cause house fire. Keep clothing, furniture, draperies and other flammable materials away. CAUTION CAUTION Check building codes prior to installation. • Installation MUST comply with local, regional, state Tested and approved for wood pellets and shelled and national codes and regulations. field corn fuel only. Burning of any other type of fuel Consult local building,fire officials or authorities having jurisdiction about restrictions, installation inspection, voids your warranty, and permits. www.quadrafire.com 7050-128B September 3, 2009 LNADR-4-HPE Santa Fe Pellet Stove 3 Dimensions and Clearances A. Appliance Dimensions 25-1/2 in. (658mm) 12-3/4 in. (324mm) I 28-11/16 in. (729mm) in. (540m540mm) Figure 8.1 -Top View Figure 8.2- Front View 1 ` 28-1/8 in. (7�1'5mm) 25-11/16 in. (653mm) o- 3-3/4 in. (95mm) 2-12 in. (64mm) I 28-3/4 in. (73mm) 16-3/4 in. (426mm) 26-7/8 in. (683mm) I 1 1 Figure 8.3 -Side View Figure 8.4 -Side View with Top Vent Adapter Page 8 7050-128B September 3, 2009 Santa Fe Pellet Stove VU9-D—R - IRE B. Clearances to Combustibles (UL and ULC) JA Alcove Installation Inches Millimeters Minimum Alcove Height 43 1092 \ Minimum Alcove Side Wall 6 152 Minimum Alcove Width 38 965 Maximum Alcove Depth 36 914 c �j Straight Back Against Inches Millimeters Wall ' A Back Wall to Appliance 2 51 y I B Side Wall to Appliance 6 152 �{Corner Installation Inches I Millimeters" �1 C I Walls to Appliance 2 51 Y'. Dimension to Coiner Inches Millimeters I Flue Center Line 8-1/2 217 _ Installation's with: J Back of Top Vent Adapter 9-1/8 232 3 to 3 inch Top Vent Adapter and 3 to 6 inch Offset Adapter ,F 'D G� JH ® WARNING z Fire Risk. FTComply with all minimum clearances to EJ combustibles as specified. / Failure to comply may cause house fire. G NOTE: Vertical Installation Inches Millimeters • Illustrations reflect typical installations and are FOR D Back Wall to Flue Pipe 3 76 DESIGN PURPOSES ONLY. • Illustrations/diagrams are not drawn to scale. E Side Wall to Cast Top 6 152 • Actual installation may vary due to individual design F Back Wall to Appliance 1 7 1 178 1 preference. Corner Installation Inches Millimeters: G Walls to Appliance 2 51 H Side Wall to Flue Pipe 3 76 September 3, 2009 7050-128B Page 9 �7vAOQA-HRE ` Santa Fe Pellet Stove C. Hearth Pad Requirements (UL and ULC) Use a non-combustible floor protector, extending beneath appliance and to the front, sides and rear as indicated. Measure front�,�ancem'M"fra;;;4;:surface of the glass door. f 1 (n L* �J i K Must extend 2 inches (51 mm) beyond each side of pipe (shaded area) 1� M Figure 10.2 Figure 10.1 *L Exception for Horizontal Installations: USA INSTALLATIONS: The non-combustible floor protector ,� must be 1/2 inch (13mm) minimum thickness, "k"value =0.49. USA Hearth Pa`d—Requirements Floor protection requires Type II thermal protection R = 1.0 or greater. Hearth Pad.3equ1re1­nen&S_ Inches A non-combustible floor protection extending beneath the K Sides 2 J1 flue pipe is recommended with horizontal venting or under L* Back 2 / the top vent adapter with vertical installation.- Figure 10.2. M Front 6 CANADA INSTALLATIONS: A non-combustible floor pro- tection extending beneath the flue pipe is required with horizontal venting or under the top vent adapter with vertical installation. Canada Hearth Tad Requirements Hearth Pad Requirements Millimeters V des 203 ck 51 otn 457 Page 10 7050-128B September 3, 2009 Santa Fe Pellet Stove4 �UEIDRA- /RE Vent Information A. Chimney and Exhaust Connection B. Venting Termination Requirements 1. Chimney & Connector: Use 3 or 4 inch (76-102mm) CAUTION diameter type"L"or"PL"venting system. It can be vented Do not terminate vent in any enclosed or semi-enclosed vertically or horizontally. area such as a carport, garage, attic, crawl space, under a 2. Mobile Home:Approved for all Listed pellet vent. If using sun deck or porch, narrow walkway or closely fenced area, the 3 inch (76mm) vertical Top Vent Adapter Kit or the 3 or any.location that can build up a concentration of fumes to 6 inch(76-152mm)Top Vent Offset Adapter, use Listed such as a stairwell, covered breezeway, etc. double wall flue connector. A Quadra-Fire Outside Air Kit must be used with manufactured home installations. 1. Termination must exhaust above air inlet elevation. It 3. Residential: The 3 inch(76mm)vertical Top VentAdapter is recommended that at least 60 inches (1.5m) of verti- Kit and the 3 to 6 inch(76-152mm)Top Vent Offset Adapter cal pipe be installed when appliance is vented directly are tested to use 24 gauge single wall flue connector or through a wall. This will create a natural draft, which Listed double wall flue connector to Class A Listed metal will help prevent the possibility of smoke or odor venting chimneys, or masonry chimneys meeting International into the home during a power outage. It will also keep Conference of Building Officials(ICBO)standards for solid exhaust from causing a nuisance or hazard by exposing fuel appliances. people or shrubs to high temperatures. The safest and preferred venting method is to extend the vent vertically 4. INSTALL VENT AT CLEARANCES SPECIFIED BY THE through the roof. VENT MANUFACTURER. 2. Distance from doors and opening windows, or gravity or 5. Secure exhaust venting system to the appliance with at ventilation air inlets into building: least 3 screws. Also secure all connector pipe joints with a. Not less than 48 inches (1.2m) below; at least 3 screws through each joint. b. Not less than 48 inches (1.2m) horizontally from; 6. DO NOT INSTALL FLUE DAMPER IN THE EXHAUST c. Not less than 12 inches (305mm) above. VENTING SYSTEM OF THIS UNIT. 7. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE 3. Distance from permanently closed windows; SERVING ANOTHER APPLIANCE. a. Not less than 12 inches(305mm)below; horizontally NOTE: All pipe must be welded seam pipe whenever pos- from or above. sible. Seal pipe joints with high temperature silicone(500°F 4. Distance between bottom of termination and grade should [260°C] minimum rated only). Do not put silicone inside be 12 inches (305mm) minimum. This is conditional of pipe. upon plants in the area, and nature of grade surface. The-grade surface must be a non-combustible material NOTE: If burning shelled field corn,you must use approved (i.e., rock, dirt). The grade surface must not be lawn. venting specifically designed for corn. Follow the instruc- Distance\between bottom of termination and public tions from the venting manufacturer. walkway should be 7 feet(2.13m) minimum. 5. Distance to combustible materials must be 24 inches WARNING (610mm) minimum. This includes adjacent buildings, Fire Risk. fences, protruding parts of the structure, roof overhang,Follow Chimney Connector Manufacturer's plants and shrubs, etc. Instructions for Proper Installation. 6. Termination Cap Location (Home Electrical Service) ONLY use connector: • Side-to-side clearance is to be the same as minimum • • Within the room, between appliance and ceiling or wall. clearance to vinyl inside corners. Connector shall NOT pass through: • Attic or roof space • Clearance of a termination cap below electrical service • Closet or similar concealed space shall be the same as minimum clearance to vinyl sof- • Floor or ceiling fits. Maintain minimum clearances to combustibles . Clearance of a termination cap above electrical service Awill be 12 inches (305mm) minimum.WARNING • Location of the vent termination must not obstruct or Vent surfaces get HOT, can cause burns if interfere with access to the electrical service. touched. Non-combustible shielding or guards may be required. September 3, 2009 7050-128B Page 11 UADRA - /�L� CONTACT INFORMATION: Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer logo onto WWW.quadrafire.com CAUTION DO NOT DISCARD THIS MANUAL 0 Important operating and • Read,understand and - Leave this manual with OAS - maintenance instruc- follow these instruc- party responsible for use C 0*1�- tions included. tions for safe installa- and operation. ��QQ tion and operation. We recommend that you record the following pertinent information for your SANTA FE PELLET STOVE Date purchased/installed: Serial Number: Location on appliance: Dealership purchased from: Dealer phone: Notes: This product may be covered by one or more of the following patents: (United States)4593510,4686807,4766876,4793322,4811534, 5000162, 5016609. 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708. 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860,6688302132,6715724132,6729551,6736133,6748940,6748942,6769426,6774802,6796302,6840261,6848441,6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S, and foreign patents pending. HEARTH&HOME technologies Page 52 7050-128B September 3, 2009