Loading...
HomeMy WebLinkAbout510 HIGH ST_BLD2265_2026 CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:510 High Street Permit#:2265 Parcel#:00411500100900 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:CLARK LONNIE M&SANDRA M Name:Evergreen State Heat&AC Name:EVERGREEN STATE HEAT&A/C Address:510 NORTH I]IGH ST Address2120 Pacific Ave Address:2120 Pacific Ave City,State Zip:ARLINGTON,WA 98223 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-252-3114 Phone:425-252-3114 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Evergreen State Heat&AC Naine: Address:2120 Pacific Ave Address: City,State,Zip: Everett,WA 98201 City,Stale,Zip: Phone:425-252-31 14 Phone: LIC#:EVERGSS0220T EXP. 10/10/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2105 STORIES: CONST.TYPE: RM DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL 1 AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY. NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RC W 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID, IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION 14 AS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110ARC110. SALES TA,1C NOTICE:Sates tax relating to constriction and construction materials in the City of Arlinglun, u• be reported on yo sales tax return fu m and coded ity of Arlin turf#3101. �,tu Bridget Whittaker 11/16/2018 - r/ �J/JCS Signature Print Name Date leas Datc CONDITIONS Adhere to approved appliance. Please call for final inspection. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC,)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/15/2018 Furnace $25.00 11/15/2018 Mechanical Permit Base Fee $25.00 11/15/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon �. ' � I 1 I CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 Go PHONE; (360) 403-3551 BUILDING PERMIT Address:510 High Street Permit#:2265 Parcel#:00411500100900 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:CLARK LONNIE M&SANDRA M Name:Evergreen State Heat&AC Name:EVERGREEN STATE HEAT&A/C Address:510 NORTH HIGH ST Address:2120 Pacific Ave Address:2120 Pacific Ave City,State Zip:ARLINGTON,WA 98223 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-252-3114 Phone:425-252-31 l4 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Evergreen State Heat&AC Name: Address:2120 Pacific Ave Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-252-31 l4 Phone: LIC#:EVERGSS0220T EXP: 10/10/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2105 STORIES: CONST.TYPE: RM DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1I0/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington mu' be reported on you sales tax return fo n and coded City of Arlington#3101, / Signature Print Name Date elelsy ( Date CONDITIONS I Adhere to approved appliance. Please call for final inspection. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/15/2018 Furnace $25.00 11/15/2018 Mechanical Permit Base Fee $25.00 11/15/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon �� i ui �: I 1 1 �, 4 Permit Information Date 11/15/2018 Permit Number 2265 Project Name Evergreen Heat-High Street Applicant Name Evergreen State Heat&AC Applicant Address 2120 Pacific Ave City,State,Zip Everett,WA 98201 Contact Ken Salo Phone 425-252-3114 Email ken@essmwa.com Permit Type Residential Mechanical Site Address 510 High Street Valuation 0.00 Status Applied Permit Issued Permit Expires Square Feet 0 Type of Construction/Occupancy Load Residential Mechanical Number of Stories 0 Proposed Use Gas furnace change out Assigned To Raelynn Jones Property Parcel Address Legal Owner Owner Phone Zoning 00411500100900 1510 HIGH ST ICLARK LONNIE M&SANDRA M 1111 Single Family Residence-Detached Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# EVERGREEN STATE HEAT&A/C POark Payne 425-252-3114 ark essmwa.com ^ONTRACTOR abor&Industries E-VERGSS0220T Fees Fee Description Notes Amount Furnace 322.10.00.00 $25.00 Mechanical Permit Base Fee 322.10.00.00 $25.00 Processin /Techn logy Fee 341.43.00.02 $25.00 Total $75.00 Notes Date Note 11/15/2018 Permit pending business license. Uploaded Files Upload File Date File Uploaded B 11/15/2018 9:51:26 AM 2265 Spe §.Ig Jone< elynn x 11/15/2018 9:51:25 AM 12265 p li i n.pd( liones,naelynn X RESIDENTIAL MECHANICAL 0 0 PERMIT APPLICATION Department of Community&Economic Development City of Arlington • 18204 59th Ave NE•Arlington, WA 98223 • Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: "fi-ve�Project Description'. cl�t 'T 11S � Owner: Address: c5 1L' City: _ /Z11kX f � ( State: `6M Zip Code: Phone: co Z Z3�� - 14f S� Email: i/ Applicant: I`��l /-fLy Address: 2-1 ? `s��Cyc �i'L City: V i State: �A Zip Code: ��r>� Phone: � ) ZS�- ;3r ( � Email: ��vlC��1155h{1 ��. CONTRACTOR INFORMATION Contractor Name: E -1 1/ZEa&1 6kar 1-!'t�rt r`G�' Ai:11 Address: 212v [A Lcf« City: eoegeTc State: W,,� Zip Code: License Number: L t✓Lizs,�' � r�� _ Expiration 1�r J�L_J Phone: 41Z-5)- Zs'Z--^11* Email: kl�?Dt IV__el S S'M 11—)Ce, Loyz,(- IR�neive� � STAFF USE ONLJY NOV 15 2018 Permit#: Z Q� Accepted by: Date: 6/16LP Page 1 of 2 Y RESIDENTIAL MECHANICAL u o PERMIT APPLICATION Department of Community&Economic Development City of Arlington • 18204 59th Ave NE•Arlington,WA 98223 • Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model# � 1)Z/3 )6_4 144l A F U E;? 5�A� 'Z)90 Heat Pump Model# AFUE HSPE I AC Unit Model# SEER DJ Freestanding Stove Qj Fire Place Insert U Outdoor BBQ Gas Piping Solid-Fuel Appliance L=I' Other Gas Piping Information Not Applicable: (� Pipe Material. Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: Date: /J /,S_ 4 Applicant Printed Name: 1 hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 \� e TUD213060MV-SUB-1 C TAG: A Upf low/Horizontal Gas Furnace - Variable Speed - 2 Stage Heat TUD2B060A9V3VB TUD2B060G9V3VA AUD2B060A9V3VB 5/8" AUD2B060G9V3VA 16-1 5/8" 1 -5 8" 28-3/8" 5/8 1/2" 4"DIAMETER FLUE CONNECT 7/8"DIA. HOLES ELECTRICAL 9-5/8" CONNECTION 4-1/16" j 1/2" 000 OOp � ? �1 3/4 Q 0 0 7/8"HOLE WITH PLUG ` \ 3-15/16" 0 2-1/16 ELECTRICAL CONNECTION 16" f'8-1/4" Q 0 (ALTERNATE) 0 3-3/4" 3/4" I 2-1/16" I 01-5/8"HOLE ' ' I WITH PLUG(2) ' 28-1/4" 28-1/4" 3/4" 22-1 `l 23-1 2" y / 5-5/16" 3-13/16" 1-1/2"DIA. HOLE �► 3/8" GAS CONNECTION 2-1/8" ©2015 Ingersoll Rand 'UD2BO6OA9V3VB,'UD2B060G9V3VA FURNACE HEATING AIRFLOW(CFM)AND POWER(WATTS)VS.EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING SW7 SW8 0.1 0.3 0.5 0.7 0.9 CFM 589 604 619 604 607 LOW ON ON TEMP.RISE 49 48 47 48 48 WATTS 65 95 125 160 200 HEATING CFM 663 694 684 681 686 1ST MEDIUM'" ON OFF TEMP.RISE 44 42 42 42 42 STAGE WATTS 75 120 145 185 220 CFM 775 781 776 805 811 HIGH OFF OFF TEMP.RISE 37 37 37 36 36 WATTS 105 145 180 230 270 CFM 813 818 818 837 842 LOW ON ON TEMP.RISE 55 54 54 53 53 WATTS 110 150 185 240 280 HEATING CFM 907 919 942 958 959 2ND MEDIUM"" ON OFF TEMP.RISE 49 48 47 46 46 STAGE WATTS 140 200 240 300 330 CFM 1038 1066 1086 1089 1079 HIGH OFF OFF TEMP.RISE 43 42 41 41 41 WATTS 190 260 325 365 415 'UD2BO6OA9V3VB,'UD2BO6OG9V3VA FURNACE COOLING AIRFLOW(CFM)AND POWER(WATTS)VS.EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING (TONS) SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 LOW CFM 499 537 520 520 500 (350 CFM/TON) ON ON OFF ON WATTS 50 80 110 145 175 1.5 NORMAL ON ON OFF OFF CFM 605 610 610 597 593 (400 CFM/TON) WATTS 60 80 120 155 180 HIGH CFM 649 681 665 665 672 (450 CFM/TON) ON ON ON OFF WATTS 75 110 145 180 220 LOW CFM 680 722 680 696 696 (350 CFM/TON) OFF ON OFF ON WATTS 80 125 150 190 225 NORMAL OFF ON OFF OFF CFM 798 804 809 823 818 2 (400 CFM/TON) WATTS 105 145 170 235 280 HIGH CFM 884 896 924 931 931 (450 CFM/TON) OFF ON ON OFF WATTS 145 180 240 280 330 LOW CFM 858 863 882 894 895 (350 CFM/TON) ON OFF OFF ON WATTS 125 175 220 275 320 2.5 NORMAL ON OFF OFF OFF CFM 984 1017 1038 1017 1017 (400 CFM/TON) WATTS 170 225 295 330 375 HIGH CFM 1125 1138 1150 1161 1161 (450 CFM/TON) ON OFF ON OFF WATTS 245 315 370 435 475 LOW OFF OFF OFF ON CFM 1035 1056 1076 1076 1076 (350 CFM/TON) WATTS 205 265 330 370 430 3" NORMAL** OFF OFF OFF OFF CFM 1208 1247 1268 1278 1200 (400C FM/TON) WATTS 300 360 440 485 490 HIGH OFF OFF ON OFF CFM 1380 1410 1402 1350 1235 (450 CFM/TON) WATTS 440 500 550 550 525 NOTES: 1."FIRST LETTER MAY BE"A"OR"T" 2.""FACTORY SETTING. 3.CONTINUOUS FAN SETTING:HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4.LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON:HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. `1 INDOOR BLOWER TIMING COOLING OFF-DELAY OPTIONS Heating: The ECM Fan Control controls the variable speed NOMINAL- indoor blower. The blower"on"time is fixed at 45 seconds after SWITCH SETTINGS SELECTION AIRFLOW ignition. The FAN-OFF period is field selectable by dip switches 5-OFF 6-OFF NONE SAME #2 and#3 on the Integrated Furnace Control at 60, 100, 140, or 180 seconds. The factory setting is 100 seconds, (See unit 5-ON 6-OFF 1.5 MINUTES 100% wiring diagram). Cooling:The fan delay-off period is set by dip switches on the 5-OFF 6-ON 3 MINUTES 50% ECM Fan Control board connected to the Integrated Furnace 5-ON 6-ON ** 50-100% Control. The options for cooling delay off is field selectable by dip switches #5 and#6. However, dip switch #1 on the Inte- *-This setting is equivalent to BAY24XO45 relay benefit grated Furnace Control must be set to"ON"for cooling mode to **-This selection provides ENHANCED MODE,which function properly. is a ramping up and ramping down of the blower speed to The following table and graph explain the delay-off settings: provide improved comfort,quietness,and potential energy savings.See Wiring Diagram notes on the unit or in the Ser- vice Facts for complete wiring setup for ENHANCED MODE. **-This selection provides a ramping up and ramping down The graph which follows,shows the ramping process. of the blower speed to provide improved comfort,quietness,and potential energy savings. The graph below shows the ramping process. 100%if necessary 80% Dehumidify 50% 50% Fast Coil Cooling Efficiency OFF OFF I 1 I 7.5 3 minute minutes minutes General Data (D TYPE UDfI0W/Horizontal VENT COLLAR—Size(in.) 4 Round RATINGS2 HEAT EXCHANGER 1st Stage Input BTUH 39,000 Type-Fired Alum.Steel 1st Stage Capacity BTUH(ICS) 3 31,200 -Unfired 2nd Stage Input BTUH 60,000 Gauge(Fired) 20 2nd Stage Capacity BTUH(ICS) 3 48,000 ORIFICES—Main Temp.rise(Min.-Max.)°F. 30-60 Nat.Gas.Qty.—Drill Size 3—45 BLOWER DRIVE DIRECT L.P.Gas Qty.—Drill Size 3—56 Diameter-Width(In.) 10 x 7 GAS VALVE Redundant-Two Stage No.Used 1 PILOT SAFETY DEVICE Speeds(No.) VARIABLE SPEED Type Hot Surface Ignition CFM vs.in.w.g. See Fan Performance BURNERS—Type Multiport Inshot Motor HP 1/2 Number 3 R.P.M. VARIABLE POWER CONN.—V/Ph/Hz U 115/1/60 Volts/Ph/Hz 115/1/60 Ampacity(In Amps) 10.5 FLA 7.7 Max.Overcurrent Protection(amps) 15 COMBUSTION FAN-Type Centrifugal PIPE CONN.SIZE(IN.) 1/2 Drive-No.Speeds Direct-2 DIMENSIONS H x W x D Motor HP-RPM 1/100-2543/1727 Crated(In.) 41-3/4 x 19-1/2 x 30-1/2 Volts/Ph/Hz 115/1/60 Uncrated(In.) 40 x 17-1/2 x 28-1/2 F.L.Amps 0.70/0.40 WEIGHT FILTER—Furnished? Yes Shipping(Lbs.)/Net(Lbs) 136/126 Type Recommended High Velocity Hi Vel.(No.-Size-Thk.)Shipped 1 -17 x 25-1 in. O Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3 ®Ratings shown are for elevations up to 2000 feet.For elevations above 2000 feet;Ratings should be reduced at the rate of 4%for each 1000 feet above sea level. O Based on U.S.Government Standard Tests. O The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. Mechanical Specifications NATURALGAS MODELS—Central heating BURNERS—Multi-port,in-shotburners will STYLING—Heavy gauge steel and"wrap- furnace designs are certified to ANSI Z21.47 give years of quiet and efficient service. All around" cabinet construction is used in /CSA 2.3 for both natural and L.P.gas. Limit models can be converted to L.P.gas without the cabinet with baked-on enamel finish for setting and rating data were established and changing burners. strength and beauty. The heat exchanger approved under standard rating conditions INTEGRATED SYSTEM section of the cabinet is completely lined with GRATED using American National Standards Institute INTE designed operational provides foil-faced fiberglass insulation. This results standards. sivel program p in quiet and efficient operation due to the total control of furnace limitsensors,blowers, excellent acoustical and insulating qualities SAFE OPERATION—The Integrated Sys- gas valve, flame control and includes self of fiberglass. tem Control has solid state devices, which diagnostics for ease of service. continuously monitor for presence of flame, FEATURES AND GENERAL OPERATION when the system is in the heating mode of AIR DELIVERY—Thevith sufficient airfloect-w — These High Efficiency Gas Furnaces operation Dual solenoid combination gas drive blower motor, with sufficient airflow omploy a Hot Surface Ignition system,which valve and regulator provide extra safety. range for most heating and cooling require- eliminates the waste of a constantly burning ments, will switch from heating to cooling system control lights QUICK HEATING—Durable, cycle tested, speeds on demand from room thermostat. the main burners upon pilot. The integrated demand for heat heavy gauge aluminized steel heat ex- The blower door safety switch will prevent or from the room thermostat. Complete front changer quickly transfers heat to provide terminate furnace operation when the blower service access. warm conditioned air to the structure. Low door is removed.(Fan relay and 35VA control energy power vent blower,to increase ef- transformer is standard). a. Low energy power venter. ficiency and provide discharge of gas fumes b. Vent proving differential switch. to the outside,allows common venting with hot water heater. Since Ingersoll Rand has a policy of continuous product and product data improvement,it reserves the right to Library change specifications and design without notice. Product Section Furnaces Product Furnace Technical Literature-Printed in U.S.A. Model TUD2-9V Literature Type Submittal ETA Ingersoll Rand Sequence Date 04/15 7 Tyler,TX5707 6200Trou Highway c us File No. TUD2_B060AW-SUB-1C �-»�� Intertek Supersedes TUD213060AW-SUB-113 Search L&ISEARCH khLa"bor & Industries Safety&Health M Claims&Insurance O Workplace Rights C Trades Washington State Department of " Labor & industries EVERGREEN STATE SHEET MTL INC Owner or tradesperson 2120 PACIFIC AVE EVERETT,WA 98201 Principals 425-252-3114 KIMBALL,RUSSELL Dron,PRESIDENT SNOHOMISH County KIMBALL,PAM,VICE PRESIDENT (End:09/27/2013) Doing business as EVERGREEN STATE SHEET MTL INC WA UBI No. Business type 601 724 357 Corporation Governing persons RUSSELL KIMBALL PAM KIMBALL; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. EVERGSS022OT Effective—expiration 09/30/1998-10/10/2019 Bond RLI Ins Co $12,000.00 Bond account no. LSM0782384 Received by L&I Effective date 11/24/2015 11/25/2015 Expiration date Until Canceled Bond history Insurance Ohio Cas Ins Co $1,000,000.00 Policy no. BKS57111316 Received by L&I Effective date 09/10/2018 09/30/2016 Expiration date 09/30/2019 Insurance history Savings No o savings accounts during the previous 6, r period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. This company has multiple workers'comp accounts. Active accounts Account no. Account is current. 959,941-00 Doing business as EVERGREEN STATE SHEETMETAL Certificate of Workers'Comp Coverage Track this contractor Account no. Account is current. 959,941-01 Doing business as EVERGREEN STATE SHEET METAL Certificate of Workers'Comp Coverage Track this contractor Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. 11'.Nhington y .: RESIDENTIAL MECHANICAL a PERMIT APPLICATION Department of Community&Economic Development City of Arlington • 18204 59th Ave NE•Arlington, WA 98223 e Phone(360)403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: /6) /7L 6/:f Project Descriptioni�2, �jL Owner: Address: City: / / , State: Zip Coder Phone: (` -05J Email: / P) /Al Applicant: �/�� Address: 2,1—Lo 1-✓I L,� City: GjU j State: l.�)A Zip Code: � �C Phone: 25-2 31 1 � Email ("ya CONTRACTOR INFORMATION Contractor Name: dtwt-j k Ad 11 Address: Zt2.t� City: EuagCfL1 State: L,,. Zip Code: License Number: /Expiration: 1111 Phone: (z/z-�) Z � ,�/<� Email ke?.41 S 5-M 4?')'ez 010 1 (- STAFF USE ONLY Permit#: Accepted by: Date: 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL e PERMIT APPLICATION Department of Community&Economic Development City of Arlington • 18204 59th Ave NE<Arlington,WA 98223 e Phone(360)403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model# 2J34 (J01VZV1 AFUE�2 9 '�_09c) Heat Pump Model# AFUE HSPE J1 AC Unit Model# SEER Freestanding Stove 4 Fire Place InsertU Outdoor BBQ El Gas Piping Solid-Fuel Appliance � Other Gas Piping Information Not Applicable: Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Applicant Signature: /'-``"ems ' Date: Applicant Printed Name: I N YoL-0 1 hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. i 6/16LP Page 2 of 2 I CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:510 High Street Permit#:2265 Parcel#:00411500100900 Valuation:0,00 OWNER APPLICANT CONTRACTOR Name:CLARK LONNIE M&SANDRA M Name:Evergreen State Heat&AC Name:EVERGREEN STATE HEAT&A/C Address:510 NORTH HIGH ST Address2120 Pacific Ave Address:2120 Pacific Ave City,State Zip:ARLINGTON,WA 98223 City,State Zip:Everett,WA 98201 City,State Zip:Everett,WA 98201 Phone: Phone:425-252-3114 Phone:425-252-3114 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:Evergreen State Heat&AC Name: Address:2120 Pacific Ave Address: City,State,Zip:Everett,WA 98201 City,State,Zip: Phone:425-252-31 t4 Phone: LIC#:EVERGSS0220T EXP: 10/10/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2105 STORIES: CONST.TYPE: RM DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Ariington,mtts be reported on you sales tax return fo and coded ity of Arlin ton#3101. a �`� Bridget Whittaker 11/16/2018 r 61 Signature Print Name Date leas Date CONDITIONS Adhere to approved appliance. Please call for final inspection. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 11/15/2018 Furnace $25.00 11/15/2018 Mechanical Permit Base Fee $25.00 11/15/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon TUD213060MV SUB-1 C TAG: E Upf low/Horizontal Gas Furnace - Variable Speed - 2 Stage Heat TUD2B060A9V3VB TUD2B060G9V3VA AUD2B060A9V3VB 5/8" AUD2B060G9V3VA 1 -1/2" 1 6-1/4 5/8" 1 28-3 8" -5 8" 5/8� 2" 4" DIAMETER FLUE CONNECT 7/8"DIA. HOLES ELECTRICAL " CONNECTION �9-5/8 000 0 T 3/4" 216" O 7/8"HOLE WITH PLUG 3-15/16" Q, -1/ ELECTRICAL CONNECTION 161' \ \\ 8-1/4" Q (ALTERNATE) LL 40" 3-3/4" 3/4" I 2-1/16" I 01-5/8"HOLE ' ` I WITH PLUG(2) ' - 28-1/4" ��. • j 3/4" `l 28-1/4" ` 22-1/2" 23-12" �� y 5-5/16" 3-13/16" 1-1/2"DIA. HOLE �► 3/$" GAS CONNECTION 2-1/8" 0 2015 Ingersoll Rand "UD2BO6OA9V3VB,"UD2B060G9V3VA FURNACE HEATING AIRFLOW(CFM)AND POWER(WATTS)VS.EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SETTING SW7 SW8 0.1 0.3 0.5 0.7 0.9 CFM 589 604 619 604 607 LOW ON ON TEMP.RISE 49 48 47 48 48 WATTS 65 95 125 160 200 HEATING CFM 663 694 684 681 686 1 ST MEDIUM"" ON OFF TEMP.RISE 44 42 42 42 42 STAGE WATTS 75 120 145 185 220 CFM 775 781 776 805 811 HIGH OFF OFF TEMP.RISE 37 37 37 36 36 WATTS 105 145 180 230 270 CFM 813 818 818 837 842 LOW ON ON TEMP.RISE 55 54 54 53 53 WATTS 110 150 185 240 280 HEATING CFM 907 919 942 958 959 2ND MEDIUM"" ON OFF TEMP.RISE 49 48 47 46 46 STAGE WATTS 140 200 240 300 330 CFM 1038 1066 1086 1089 1079 HIGH OFF OFF TEMP.RISE 43 42 41 41 41 WATTS 190 260 325 365 415 *UD2BO6OA9V3VB,"UD2B060G9V3VA FURNACE COOLING AIRFLOW(CFM)AND POWER(WATTS)VS.EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING (TONS) SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9 LOW ON ON OFF ON CFM 499 537 520 520 500 (350 CFM/TON) WATTS 50 80 110 145 175 15 NORMAL ON ON OFF OFF CFM 605 610 610 597 593 (400 CFM/TON) WATTS 60 80 120 155 180 HIGH CFM 649 681 665 665 672 (450 CFM/TON) ON ON ON OFF WATTS 75 110 145 180 220 LOW CFM 680 722 680 696 696 (350 CFM/TON) OFF ON OFF ON WATTS 80 125 150 190 225 NORMAL OFF ON OFF OFF CFM 798 804 809 823 818 2 (400 CFM/TON) WATTS 105 145 170 235 280 HIGH CFM 884 896 924 931 931 (450 CFM/TON) OFF ON ON OFF WATTS 145 180 240 280 330 LOW CFM 858 863 882 894 895 (350 CFM/TON) ON OFF OFF ON WATTS 125 175 220 275 320 2.5 NORMAL ON OFF OFF OFF CFM 984 1017 1038 1017 1017 (400 CFM/TON) WATTS 170 225 295 330 375 HIGH CFM 1125 1138 1150 1161 1161 (450 CFM/TON) ON OFF ON OFF WATTS 245 315 370 435 475 LOW OFF OFF OFF ON CFM 1035 1056 1076 1076 1076 (350 CFM/TON) WATTS 205 265 330 370 430 3"" NORMAL" OFF OFF OFF OFF CFM 1208 1247 1268 1278 1200 (400 CFM/TON) WATTS 300 360 440 485 490 HIGH OFF OFF ON OFF CFM 1380 1410 1402 1350 1235 (450 CFM/TON) WATTS 440 500 550 550 525 NOTES: 1."FIRST LETTER MAY BE"A"OR"T" 2.""FACTORY SETTING. 3.CONTINUOUS FAN SETTING:HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50%OF SELECTED COOLING VALUE. 4.LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT&HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON:HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING. INDOOR BLOWER TIMING COOLING OFF-DELAY OPTIONS Heating: The ECM Fan Control controls the variable speed NOMINAL- indoor blower. The blower"on"time is fixed at 45 seconds after SWITCH SETTINGS SELECTION AIRFLOW ignition. The FAN-OFF period is field selectable by dip switches 5-OFF 6-OFF NONE SAME #2 and#3 on the Integrated Furnace Control at 60, 100, 140, or 180 seconds. The factory setting is 100 seconds, (See unit 5-ON 6-OFF 1.5 MINUTES 100% wiring diagram). Cooling:The fan delay-off period is set by dip switches on the 5-OFF 6-ON 3 MINUTES 50% ECM Fan Control board connected to the Integrated Furnace 5-ON 6-ON ** 50- 100% Control. The options for cooling delay off is field selectable by dip switches #5 and #6. However, dip switch #1 on the Inte- grated Furnace Control must be set to"ON for cooling mode to *-This selection provides ENHANCED MODE,which function properly. is a ramping up and ramping down of the blower speed to The following table and graph explain the delay-off settings: provide improved comfort,quietness,and potential energy savings.See Wiring Diagram notes on the unit or in the Ser- vice Facts for complete wiring setup for ENHANCED MODE. **-This selection provides a ramping up and ramping down The graph which follows,shows the ramping process. of the blower speed to provide improved comfort,quietness,and potential energy savings. The graph below shows the ramping process. 100%if necessary 80% Dehumidify 50% 50% Fast Coil Cooling Efficiency OFF OFF 1 I 7.5 1 I 3 minute minutes minutes General Data o TYPE U flow/Horizontal VENT COLLAR—Size(in.) 4 Round RATINGS 2 HEATEXCHANGEff 1st Stage Input BTUH 39,000 Type-Fired Alum.Steel 1st Stage Capacity BTUH(ICS) 3 31,200 -Unfired 2nd Stage Input BTUH 60,000 Gauge(Fired) 20 2nd Stage Capacity BTUH(ICS) 3 48,000 ORIFICES—Main Temp.rise(Min.-Max.)°F 30-60 Nat.Gas.Qty.—Drill Size 3—45 BLOWER DRIVE DIRECT L.P.Gas Qty.—Drill Size 3—56 Diameter-Width(In.) i 0 x 7 A L Redundant-Two Stage No.Used 1 PIL T AFETY DEVICE Speeds(No.) VARIABLE SPEED Type Hot Surface Ignition CFM vs.in.w.g. See Fan Performance BURNERS—Type Multiport Inshot Motor HP 1/2 Number 3 R.P.M. VARIABLE POWER CONN. V/Ph/Hz 115/1/60 Volts/Ph/Hz 115/1/60 Ampacity(in Amps) 10.5 FLA 7.7 Max.Overcurrent Protection(amps) 15 COMBUSTION FAN-Type Centrifugal PIPE CONN.SIZE(IN.) 1i2 Drive-No.Speeds Direct-2 DIMENSIONS H x W x D Motor HP-RPM 1/100-2543/1727 Crated(In.) 41-3/4 x 19-1/2 x 30-1/2 Volts/Ph/Hz 115/1/60 Uncrated(In.) 40 x 17-1/2 x 28-1/2 F.L.Amps 0.70/0.40 WEIGHT FILTER—Furnished? Yes Shipping(Lbs.)/Net(Lbs) 136/126 Type Recommended High Velocity Hi Vel.(No.-Size-Thk.)Shipped 1 -17 x 25-1 in. O Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3 O Ratings shown are for elevations up to 2000 feet.For elevations above 2000 feet;Ratings should be reduced at the rate of 4%for each 1000 feet above sea level. O Based on U.S.Government Standard Tests. O The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. Mechanical Specifications NATURALGAS MODELS—Central heating BURNERS—Multi-port,in-shotburners will STYLING—Heavy gauge steel and"wrap- furnace designs are certified to ANSI Z21.47 give years of quiet and efficient service. All around" cabinet construction is used in /CSA 2.3 for both natural and L.P.gas. Limit models can be converted to L.P.gas without the cabinet with baked-on enamel finish for setting and rating data were established and changing burners. strength and beauty. The heat exchanger approved under standard rating conditions section of the cabinet is completely lined with using American National Standards Institute INTEGRATED SYSTEM CONTROL—Exclu- foil-faced fiberglass insulation. This results standards. sively designed operational program provides in quiet and efficient operation due to the total control of furnace limit sensors,blowers, excellent acoustical and insulating qualities SAFE OPERATION—The Integrated Sys- gas valve, flame control and includes self of fiberglass. tem Control has solid state devices, which diagnostics for ease of service. continuously monitor for presence of flame, FEATURES AND GENERAL OPERATION AIR DELIVERY—The variable speed,direct- when the system is in the heating mode of drive blower motor, with sufficient airflow — These High Efficiency Gas Furnaces operation. Dual solenoid combination gas range for most heating and cooling require- employ a Hot Surface Ignition system,which valve and regulator provide extra safety. ments, will switch from heating to cooling eliminates the waste of a constantly burning pilot. The integrated system control lights QUICK HEATING—Durable, cycle tested, speeds on demand from room thermostat. the main burners upon a demand for heat heavy gauge aluminized steel heat ex- The blower door safety switch will prevent or changer quickly transfers heat to provide terminate furnace operation when the blower from the room thermostat. Complete front service access. warm conditioned air to the structure. Low door is removed.(Fan relay and 35VA control energy power vent blower,to increase ef- transformer is standard). a. Low energy power venter. ficiency and provide discharge of gas fumes b. Vent proving differential switch. to the outside,allows common venting with hot water heater. Since Ingersoll Rand has a policy of continuous product and product data improvement,it reserves the right to Library - change specifications and design without notice. Product Section Furnaces Product Furnace Technical Literature Model TUD2-9V Printed in U.S.A. Literature Type Submittal Sequence - Ingersoll Rand Date 04/15 7 Tyler,TX5707 6200Trou Highway c File No. TUD2B060A9V-SUB-1C 'ti+0 Intertek Supersedes TUD213O60A9V-SUB-113 Permit#: 2265 Permit Date: 11/15/18 Permit Type: RESIDENTIAL MECHANICAL Project Name: Evergreen Heat- High Street Applicant Name: Evergreen State Heat&AC Applicant Address: 2120 Pacific Ave Applicant, City, State, Zip: Everett,WA 98201 Contact: Ken Salo Phone: 425-252-3114 Email: ken@essmwa.com Scope of Work: Gas furnace change out Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 11/16/2018 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 00411500100900 510 HIGH ST CLARK LONNIE M 111 Single Family &SANDRA M Residence-Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# EVERGREEN STATE Mark Payne 425-252-3114 2120 Pacific Ave CONSTRUCTION COA 601-724-357 HEAT&A/C CONTRACTOR EVERGREEN STATE Mark Payne 425-252-3114 2120 Pacific Ave CONSTRUCTION Labor&EVERGSS0220T HEAT&A/C CONTRACTOR Industries Fees Fee Description Notes Amount Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Total $75.00 Attached Letters Date Letter Description 11/15/2018 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 11/16/2018 Ken Salo 72656479 cc $75.00 Outstanding Balance $0.00 Notes Date Note Created By: 11/16/2018 Approved license.RJ Raelynn Jones 11/15/2018 Permit pending business license. Raelynn Jones Uploaded Files Date File Name 11/16/2018 4201830-2265 Permit for signature.pdf 11/15/2018 4197143-2265 Specs.pdf 11/15/2018 4197142-2265 Application.pdf