Loading...
HomeMy WebLinkAbout16419 40TH DR NE_BLD2210_2026 r - GITY OF ARLINGTON - ARLINGTON, WA. 98223 238 N. OLYMPIC AVE PHONE; (360) 403-3551 BUILDING PERMIT Address:16419 40th DR NE Permit#:2210 Parcel#:00866800023000 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:Sandra Stanford Name:C.M.Heating Name:C.M.HEATING INC Address: 16419 40TH DR NE Address:1415 Broadway Address: 1415 BROADWAY City,State Zip:ARLINGTON,WA 98223-8449 City,State Zip:Everett,WA 98201 City,State Zip:EVERETT,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-6666 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: STORIES: CONST.TYPE: DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC 110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arlington must be reported on your sales tax return form and coded City of Arlington#3101. Ad'.t'l)I IA L IPA Signature Print Name Date R sed B Date CONDITIONS THIS PERMIT AUTHORIZE ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/15/2018 Furnace $25.00 10/15/2018 Mechanical Permit Base Fee $25.00 10/15/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $0.00 Balance Due: $75.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon i RESIDENTIAL MECHANICAL PERMIT APPLICATION , Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address:16419 40th DR NE, ARLINGTON 98223 Project Description:REPLACE GAS FURNACE Owner: SANDRA STANDORD Address: 16419 40TH DR NE City:ARLINGTON State WA Zip Code: 98223 Phone: 360-322-0628 Email:ryansalexander@hotmail.com Applicant: C.M. HEATING INC Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 Phone: 425-259-0550 Email: DEBBIE@CMHEAIING.COM CONTRACTOR INFORMATION Contractor Name:C.M. HEATING INC Address: 1415 BROADWAY City: EVERETT State WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration: 05/19 Phone:425-259-0550 Email:DEBBIE@CMHEAITNG.COM Received STAFF USE ON Y OCT 1 S M18 Permit #: ��U Accepted by: Date: 6/16LP Page 1 of 2 RESIDENTIAL MECHANICAL w • �fl •O PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223 • Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #GDH80603AX AFUE80% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances -�—Applicant Signature: __ Date: 10/12/2018 Applicant Printed Name: Debbie Bauers I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 CITY OF ARLINGTON 238 N. OLYMPIC AVE-ARLINGTON, WA. 98223 ` PHONE; (360) 403-3551 BUILDING PERMIT Address:16419 40th DR NE Permit#:2210 Parcel#:00866800023000 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:Sandra Stanford Name:C.M,Heating Name:C.M.HEATING INC Address: 16419 40TH DR NE Address:1415 Broadway Address: 1415 BROADWAY City,State Zip:ARLINGTON,WA 98223-8449 City,State Zip:Everett,WA 98201 City,State Zip:EVERETT,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-6666 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:C.M.HEATING INC Name: Address: 1415 BROADWAY Address: City,State,Zip:EVERETT,WA 98201 City,State,Zip: Phone:425-259-6666 Phone: LIC#:CMHEAI*095R4 EXP: 05/03/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18,27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC1I0/IRC110. -SALES TAX NOTICE:Salcs tax relating to construction and construction materials in the City of Art g �•t .It e ry cd on"sales tax return form at coded Cily of AjJi gton#3101. _� -ogw ��'� - W V Sigua rc Print Nam Date a asetl By Date CONDITIONS Approved as submitted. Inspection required. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY, ANY CONSTRUCTION ON rHE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/16/2018 Furnace $25.00 10/16/2018 Mechanical Permit Base Fee $25.00 10/16/2018 Processing(Technology Fee $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon GITY OF ARUNGTON \\, % 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:16419 40th DR NE Permit#:2210 Parcel#:00866800023000 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:Sandra Stanford Name:C.M.Heating Name:C.M.HEATING INC Address: 16419 40TH DR NE Address:1415 Broadway Address: 1415 BROADWAY City,State Zip:ARLINGTON,WA 98223-8449 City,State Zip:Everett,WA 98201 City,State Zip:EVERETT,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-6666 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:C.M.HEATING INC Name: Address: 1415 BROADWAY Address: City,State,Zip:EVERETT,WA 98201 City,State,Zip: Phone:425-259-6666 Phone: LIC#:CMHEAI*095R4 EXP: 05/03/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/1RC1I0. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arl' g i/ st e r cd on you sales tax return form and coded City of Arlington#3101. �• W V Signature Print Name Date c •sed By Date CONDITIONS Approved as submitted. Inspection required. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/16/2018 Furnace $25.00 10/16/2018 Mechanical Permit Base Fee $25.00 10/16/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon GMH8/GDH8 Air Conditioning&Heating HEATING INPUT: 40,000-140,000 BTU/H TWO-STAGE CONVERTIBLE MULTI SPEED GAS FURNACES 80°o AFUE Contents Nomenclature........................................2 Product Specifications...........................3 Dimensions............................................5 Airflow Data...........................................7 Wiring Diagram....................................10 Accessories........................................ .11 Minimum Filter Sizes ......................... 11 I .. Standard Features Cabinet Features • Heavy-duty aluminized-steel dual- • Multi-position installation: diameter,tubular heat exchanger GMH8:upflow,horizontal left or right • Two-stage convertible gas valve GDH8:dedicated downflow automatically adjust to high or low stage • Convenient left or right connection • Durable Silicon Nitride igniter for gas and electrical service • Quiet single speed draft inducer • Cabinet air leakage(QLeak)<2% • Self-diagnostic control board with constant memory fault code • Heavy-gauge steel cabinet with • Color-coded low-voltage terminals with provisions durable baked-enamel finish for electronic air cleaner and humidifier • Fully insulated heat exchanger • Multi-speed blower motor and blower section Received • Low continuous fan speed options offer quiet air circulation • California Low NOx emissions standards models available • For installation in California's South Coast Air Quality Management District(SCAQMD)only: This furnace does not meet the SCAQMD Rule 111114 ng/J NOx emission limit,and thus is subject to a mitigation fee of up to ( L I F E T I M E 10 U N I T 10 PARTS HEAT EXCHANGER LIMITED LIMITED $450.This furnace is not eligible for the LIMITED WARRANTY' YEAR WARRANTY'I YEAR WARRANTY' SCAQMD Clean Air Furnace Rebate COMPANY Wml COMPANY WIM BBB C1 �11M OUA4TY8YBTEM OCERDNMERALEYBTEM Program:www.CleanAirFurnaceRebate.com. l` ® CERrIFIEDRYDNVOL CERONMENT DNYOL • AHRI Certified;ETL Listed •Imml. =IED,IW,= Complete warranty details available from your local dealer or at www.goodmanmfg. com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty,online registration must be completed within 60 days of installation.Online registration is not required in California or Quebec. SS-GMH8 www.goodrnanmfg.com 9/18 Supersedes 5/17 NOMENCLATURE G M H 80 040 3 B X • 1 2 4 5,6 7,8,9 10 11 12 13,14 BRAND ENGINEERING G-Goodman®Brand Major/Minor Revisions CONFIGURATION M-Upflow/Horizontal NOx C-Downflow/Horizontal N-Natural Gas D-Dedicated Downflow X-Low NOx GAS VALVE H-Convertible Two-Stage,Single Phase CABINET WIDTH S-Single Stage,Single Speed A-14" C-21" B-17A" D-24%" AFUE 80-80%AFUE MAxIMUM CFM 3-1200CFM MBTU/H 4-1600 CFM 040-40,000 BTU/h 100-100,000 BTU/h 5-2000 CFM 060-60,000 BTU/h 120-120,000 BTU/h 080-80,000 BTU/h 140-140,000 BTU/h 2 www.goodmanmfg.com SS-G M H8 PRODUCT SPECIFICATIONS— GMH8 HEATING CAPACITY Input 40,000 60,000 60,000 80,000 80,000 80,000 100,000 120,000 140,000 Natural Gas Output 32,000 48,000 48,000 64,000 64,000 64,000 80,000 96,000 112,000 LP Gas Output 32,000 48,000 48,000 64,000 64,000 64,000 80,000 96,000 96,000 AFUE' 80 80 80 80 80 80 80 80 80 Available AC @ 0.5"ESP 3 3 4 3 4 5 5 5 5 Temperature Rise Range(°F) 25-55 20-50 20-50 35-65 35-65 35-65 35-65 40-70 40-70 CIRCULATOR BLOWER Size (DxW) 10"x6" 10"x6" 10"x8" 10"x8" 10"x8" 10"x10" 10"x10" 11"x10" 11"x10" Horsepower @1075 RPM %3 % % %3 % '/z % % 3% Speed 4 4 4 4 4 4 4 4 4 Vent Diameter Z 4" 4" 4" 4" 4" 4" 4" 4" 4" No.of Burners 2 3 3 4 4 4 5 6 6 ELECTRICAL DATA Min.Circuit Ampacity 3 4.8 4.8 8.8 4.8 8.8 8.8 8.8 14.7 14.7 Max.Overcurrent Device(amps)4 15 15 15 15 15 15 15 1 15 15 SHIP WEIGHT(LBS) 86 90 98 106 107 114 t__118 1 132 132 ' DOE AFUE based upon Isolated Combustion System(ICS) 3 Vent and combustion air diameters may vary depending upon vent length_Referto the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA B149.1 and CAN/CSA B142.2(in Canada). 3 Minimum Circuit Ampacity=(1,25 x Circulator BlowerAmps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. • Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply. • Gas Service Connection M"FPT • Important;Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. SS-GMH8 www.goodmanmfg.com 3 PRODUCT SPECIFICATIONS— Mie 040 0.0 0r HEATING CAPACITY Input 40,000 60,000 80,000 100,000 Natural Gas Output 32,000 48,000 64,000 80,000 LP Gas Output 32,000 48,000 64,000 80,000 AFUE' 80 80 80 80 Availahll'AC @ 0.5"FSP 25-55 30-60 35-65 40-70 Temperature Rise Range(°F) 3 3 4 5 CIRCULATOR BLOWER Size (DxW) 1OX6 1OX6 1OX8 10X10 Horsepower @1075 RPM 1/3 1/3 1/2 3/4 Speed 4 4 4 4 Vent Diameter Z 4 4 4 4 No.of Burners 2 3 4 5 ELECTRICAL DATA Min.Circuit Ampacity a 4.8 4.8 8.8 12.9 Max.Overcurrent Device(amps)° 15 15 15 15 SHIP WEIGHT(LBS) 88 92 106 1 114 DOE AFUE based upon Isolated Combustion System(ICS) 2 Vent and combustion air diameters may vary depending upon vent length,Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA B149.1 and CAN/CSA B142.2(in Canada). Minimum Circuit Ampacity=(1.25 x Circulator Blower Amps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes. Fxtensive wire n ina will rerjmre larger wire 517e5 • Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply. • Gas Service Connection%"FPT • Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. 4 www.goodmanmfg.com SS-G M H8 GMH8 DIMENSIONS Altemate Gas Inlet I Alt.Flue Outlet—Horizontal Left �B� 194„ l 33%" Alt.Gas Inlet 27%I " _T High-Voltage Inlet 20 I 23s/16" Alt.High Voltage 13YV 15" Low-Voltage Inlet Alt.Law Voltage f �— —2 �! 23„ 8" MODEL .. GMH80403A*B 14" 123/2" GMH80805C*B 21" 19'/z" GMH80603A*B 14" 12%" GMH81005C*B 21" 19'/z" GMH80604B*B 17%" 16" GMH81205D*B 24%" 23" GMH80803B*B 17%" 16" GMH81405D*B 24%" 23" GMH80804B*B 17%" 16" Notes • Line voltage wiring and low-voltage wiring can enter through the right or left side of furnace. • Conversion kits for high-altitude(4500+ft)natural gas operation are available.Contact your Goodman distributor or dealer for details. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS SIDES REAR FRONT' VENT' .• 1" 0" 3" 6" 1" 1" 24"clearance for serviceability recommended. Single Wall Vent(SW)to be used only as a connector.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA B149.1 and CAN/CSA 0142.2(in Canada). Note:GMH8 approved for line contact in the horizontal position. SS-GMH8 www.goodmanmfg.com 5 GDH8 DIMENSIONS 28" A s' 19 B High-Voltage Electrical Low-Voltage , Flartrical �• O 00 0 Gas Inlet 33%" 0 0 0 0 MODELNON-COMBUSTIBLE •.• BASE G D H80403A*B 14" 12'Y2" SBT14 GDH80603A*B 14" 12%=" SBT14 GDH80804B*B 17%" 16" SBT17 G DH81005C*B 21" 19'/:" SBT21 NOTES • Line voltage wiring and low-voltage wiring can enter through the right or left side of furnace. • Conversion kits for high-altitude(4500+ft)natural gas operation are available.Contact your Goodman distributor or dealer for details. • Installer must supply the following gas line fittings,according to which entrance is used: 0 Left:one 909 street elbow;one 2%"pipe nipple;one 909 elbow;straight pipe;one ground joint union 0 Right:Straight pipe to reach gas valve MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS SIDES HEAR I-RONT' VENT .• SW 1,. 01 3„ 6N 1N 1N 24"clearance for serviceability recommended, ] Single Wall Vent(SW)to be used only as a connector.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA B149,1 and CAN/CSA B142.2(in Canada). Note:GMHB approved for line contact in the horizontal position. 6 www.goodmanmfg.com SS-GMH8 GMH8 AIRFLOW DATA (CFM&TEMPERATURE RISE v5.EXTERNAL STATIC PRESSURE) EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) MODEL MOTOR TONS 0.1 SPEED AC' ®®®®®®®®®®®® High 3 1,S21 --- 1,466 --- 1,414 --- 1,373 --- 1,298 --- 1,243 1,164 1,075 GMH8 Med 2.5 1,160 26 1,160 26 1,132 26 1,121 26 1,082 27 1,042 997 925 0403A*B Med-Lo 2 961 31 955 31 948 31 932 32 913 33 882 821 803 Low 1.5 781 38 785 38 781 38 773 38 761 32 745 716 668 High 3 1,422 31 1,352 33 1,307 34 1,197 37 1,157 38 1,092 1,075 983 GMH8 Med 2.5 1,098 40 1,081 41 1,051 42 1,039 43 1,021 44 983 924 868 0603A*13 Med-Lo 2 919 48 913 49 892 50 847 ---- 829 ---- 818 792 728 Low 1.5 7S8 ---- 741 - 741 - 733 - 699 ---- 677 649 626 High 4 2,134 21 2,100 21 2,042 22 1,975 23 1,883 24 1,786 1,700 1,601 GMH8 Med 3.5 1,668 27 1,663 27 1,656 27 1,645 27 1,616 28 1,549 1,492 1,391 0604E*B Med-Lo 3 1,419 31 1,426 31 1,426 31 1,432 31 1,419 31 1,378 1,328 1,261 Low 2.5 1,134 39 1,145 39 1,166 38 1,171 38 1,160 38 1,144 1,111 1,071 High 3 1,607 37 1,S72 38 1,547 39 1,498 40 1,448 41 1,390 1,302 1,222 GMH8 Med 2.5 1,159 51 1,1S6 51 1,145 52 1,127 53 1,108 53 1,075 1,033 957 0803B*B Med-Lo 2 938 63 916 65 916 65 900 ---- 889 --- 86S 829 785 Low 1.5 785 ---- 766 --- 743 ---- 730 ---- 709 -- 683 666 604 High 4 2,051 --- 1,983 ---- 1,895 --- 1,812 --- 1,725 --- 1,627 1,530 1,439 GMH8 Med 3.5 1,736 --- 1,708 35 1,652 36 1,611 37 1,540 38 1,475 1,394 1,307 08046*8 Med-Lo 3 1,493 35 1,668 36 1,459 41 1,429 41 1,389 43 1,339 1,274 1,204 Low 2.5 1,200 49 1,185 50 1,180 50 1,173 51 1,158 51 1,125 1,125 1,080 High 5 2,290 ---- 2,229 ---- 2,155 ---- 2,047 -- 1,960 ---- 1,837 1,712 1,584 GMH8 Med 4 1,852 --- 1,820 -- 1,777 --- 1,719 --- 1,641 36 1,567 1,469 1,382 0805C*B Med-Lo 3.5 1,61S 37 1,592 37 1,5S6 38 1,516 39 1,470 40 1,40S 1,346 1,235 Low 3 1,290 46 1,285 46 1,265 47 1,235 48 1,214 49 1,174 1,044 904 High 5 2,323 --- 2,225 --- 2,120 35 2,040 36 1,974 38 1,801 1,688 1,577 GMH8 Med 4 1,858 40 1,847 40 1,799 41 1,744 42 1,674 44 1,577 1,493 1,399 100SC*B Med-Lo 3.5 1,596 46 1,587 47 1,571 47 1,552 48 1,493 50 1,397 1,326 1,217 Low 3 1,291 57 1,272 S8 1,261 59 1,257 59 1,205 61 1,168 1,118 1,060 High 5 2,469 --- 2,389 --- 2,300 --- 2,223 40 2,131 42 2,027 1,902 1,786 GMH8 Med 4 1,575 56 1,558 S7 1,S45 58 1,513 59 1,500 59 1,419 1,354 1,271 120SD*B Med-Lo 3.5 1,402 63 1,380 64 1,343 66 1,319 67 1,296 69 1,245 1,183 1,106 Low 3 1,200 - 1,186 ---- 1,161 ---- 1,127 ---- 1,082 ---- 1,042 99S 926 High 5 2,469 42 2,389 43 2,300 45 2,223 47 2,131 49 2,027 1,902 1,786 GMH8 Med 4 1,575 66 1,558 67 1,545 67 1,S13 69 1,S00 69 1,419 1,354 1,271 1405D*C Med-Lo 3.5 1,402 - 1,380 - 1,343 -- 1,319 -- 1,296 ---- 1,245 1,183 1,106 Law 3 1,200 ---- 1,186 - 1,161 --- 1,127 - 1,082 ---- 1,042 995 926 @ 0.5"ESP NOTES • CFM in chart is without filter(s).Filters do not ship with this furnace,but must be provided by the installer.If the furnace requires two return filters,this chart assumes both filters are installed. • All furnaces ship as high-speed cooling and medium-speed heating.Installer must adjust blower cooling and heating speed as needed. • For most jobs,400 CFM per ton for cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • This chart is for information only. For satisfactory operation,external static pressure should not exceed value shown on the rating plate. • The dashed(----)areas indicate a temperature rise not recommended for this model. • At higher altitudes,a properly Berated unit will have approximately the same temperature rise at a particular CFM,while ESP at the CFM will be lower. SS-GMH8 www.goodmanmfg.com 7 GDH8 AIRFLOW DATA (CFM&TEMPERATURE RISE v5.EXTERNAL STATIC PRESSURE) ®®®® RISE CFM RISE CFM High 3.0 1,353 --- 1,290 -- 1,246 --- 25 1,149 26 1,116 1,116 1,099 GDH8 Med 2.5 1,183 25 1,113 27 1,098 27 1,052 28 1,039 29 1,006 1,012 969 0403A*B (Med)2 Med-Lo 2.0 980 30 946 31 920 32 900 33 896 33 885 855 804 Low 1.S 778 38 762 39 738 40 746 40 738 40 717 696 678 High 3.0 1,290 34 1,236 36 1,194 37 1,166 38 1,176 38 1,166 1,108 1,029 GDH8 Med 2.5 1,139 39 1,090 41 1,035 43 1,063 42 1,063 42 1020 962 89S 0603A*B (Med)Z Med-Lo 2.0 962 46 927 48 92S 48 941 47 909 49 877 834 779 Low 1.5 787 56 776 57 763 58 744 60 723 --- 690 641 581 High 4.0 2,128 --- 2,063 --- 2,001 --- 1,927 --- 1,824 --- 1,726 1,628 1,529 GDH8 Med 3.5 1,840 --- 1,788 --- 1,745 --- 1,689 3S 1,62S 36 1,550 1,470 1,364 08046*B (Med)2 Med-Lo 3.0 1,602 37 1,558 38 1,543 38 1,493 40 1,455 41 1,402 1,328 1,239 Low 2.5 1,277 46 1,252 47 1,244 48 1,229 48 1,214 49 1,179 1141 1079 High 5.0 2,405 - 2,361 --- 2,250 -- 2,161 - 2,037 36 1,937 1,808 1,689 GDH8 Med 4.0 1,880 39 1,838 40 1,794 41 1,734 43 1,677 44 1,568 1510 1,401 100SC*B (Med)l Med-Lo 3.5 1659 45 1,630 45 1,587 47 1,537 48 1,492 SO 1,445 1,368 1,287 Low 3.0 1,472 50 1,454 51 1,404 53 1,366 54 1,326 56 1300 1228 1139 ' Heating speed as shipped z @ 0.5"ESP NOTES • CFM in chart is without filter(s).Filters do not ship with this furnace,but must be provided by the installer.If the furnace requires two return filters,this chart assumes both filters are installed. • All furnaces ship as high-speed cooling and medium-speed heating.Installer must adjust blower cooling and heating speed as needed. • For most jobs,400 CFM per ton for cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • This chart is for information only. For satisfactory operation,external static pressure should not exceed value shown on the rating plate. The dashed(----)areas indicate a temperature rise not recommended for this model. • At higher altitudes,a properly derated unit will have approximately the same temperature rise at a particular CFM,while ESP at the CFM will be lower. 8 www.goadmanmfg.com SS-G M H8 TEMPERATURE RISE RANGE CHART O 14.1 - O a � x _ °O LL 0 x g 00 CIO = O cc LL a o U 3 -� II �_ x _ O Y 2 - LL D � LL O m - O D - N 0 - r � m m OC - Q - O U - W (n _ 12 L W U - O O w -oo _ O 0 D _ H _ o paC o N X IL I CW O N G O - O W COO - 0 _ m - 00-0 _ 0 H a 0 - 00O' o - O o �o - o - \ o 0) - O co ti H � - 00 0 0 _ LL U O o �p 0 c0 O LO O It - O O co O O Lo(0c� N a) 00 3SI� 3biniVd3dW31 SS-GMH8 www,goodmanmfg.com 9 WIRING DIAGRAM ----- WARNING DISCONNECT POWER BEFORE I--------�NUMIGIiIER U-D INTEGRATED SERVICING•WIRING TO UNIT MUST BE I ---- CONTROL MODULE PROPERLY POLARIZED AND GROUNDED. I IXFAIR(6) GND U woo RO E I 1 IIWNpflER Mvc I% / HI VALVE 1 I MVH(12) pro MVL 12) C )OOLONER AU%ILIARV I PRESSURE ft4d0 y LIMIT CONTROLS SNATCH Z O /M It01 C NO b WN T" i UT a l °¢x TO MO AI 0 hr4Fa c�II 41CR0�Mli(7) •A • BL II ItAlG ltl Q ^ FUSE S F I ORRAARY T \. ! EENNOOTEaCONTROL ♦\ ER AUXILIARY LIMITS ROI la) INrEGR OL —TRM000LE L J' WgRL11-REbEr ROl10Vf v LIMIT CONTROL(S) 3 iiYR(31 ($WGLE CONTROL ON SQW MOOELO) a TD i 21 VAC y O IL NN TRANSFORMA RD > ? g R ifFARTI 115VAC XFMR-N 5 C T lLAMt UENSON 'E m O if NOT SURFACE � s sl ONITER A [:W!-M IIhl a.EArt:N I p IGN rr — tW tN Gl � m D C va 3 go a I RI vAA u.fFN 0 0 O m R% 24V a ¢ � n 0 N 115V S S COOL CIRCULATOR O W BLVJR CIR-N XFMR ON m:�. � O NR ELECTRONIC�1— O 15 PIN PLUG EhC.11 AIR CLEANED/ EhCI 11 O. ON SOME MODELS �•——— W _ ELONER G01/PARINtENT UNE.t1 IRr:-.v '0 � BURNER COMPARTMENT JUNCTION BOX C C C ODOR SNnrcN ��WICER sw�icH ^T( IT1 O vvi ANITCH LOCATEOIN SLOKER 1 V 1 aT CpNPAR1A1jlN�T}ONNSSSO_M,EE MODELS I O/O I I F, f L `./ WARNING: ui D rl RREaaURE yt DISCONNECT POWii 1 q�OM11ECr m E BEFORE SERVICING. I RalAupv L1wr sNnrcH WIRING TO UNIT j w °D MUST BE ) YL PROPERLY I I m vl N1 POLARIZED 1 I = ° AND GROUNDED. — ^^ L GND N eR f w BL OVERCURRENT PROTECTION DEVICE Z AAI OX ' 'M O I JUNCTION HOT BOX SURFACE 2STAGE — LINE-N IGNITER GAS VALVE (HONEY WELL) 0 — GND MI — LINE �T INDUCED DRAFT BLOWER T0115 VAC/1/60H2 \VI PS RU I FLAME POWER SUPPLY WITH SENSOR OVERCURRENTPROTECTION OLLOUT LJMITS DEVICE N If WOLF CONTROL dvEWENOOELE) rya Y m 0 STEADY ON=NORMAL OPERATION 3 0 OFF =CONTROL FAILURE LOW VOLTAGE(24V) EQUIPMENT GND r7L7 ai E v 1 FLASH = SYSTEM LOCKOUT RETRIESIRECYCLES EXCEEDED LOW VOLTAGE FIELD ( ) FIELD GND f m D 2 2 FLASHES=PRESSURE SWITCH STUCK CLOSED HI VOLTAGE(115V) u n m 3 FLASHES=PRESSURE SWITCH STUCK OPEN FIELD SPLICE oHI VOLTAGE FIELD --- 4 FLASHES=OPEN HIGH LIMIT SWITCH(TEMP.) o-5-0 v .3 p 5 FLASHES=FLAME SENSE WITHOUT GAS VALVE JUNCTION E J1NL N IGNITER 6 FLASHES=OPEN ROLLOUT OR OPEN FUSE TERMINAL ¢ N y 7 FLASHES=LOW FLAME SIGNAL INTERNAL TO SWITCH(PRESS.) — ° m 0 `o e B FLASHES=CHECK IGNITER OR IMPROPER GROUND INTEGRATED CONTROL OVERCURRENT w c RAPID FLASHES=REVERSED 115 VAC POLARITYNERIFY GND PLUG CONNECTION PROT.DEVICE v NOTES: COLOR CODES: PK PINK 1.SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2.MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. YL YELLOW BR BROWN 3.IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE OR ORANGE WH WHITE REPLACED,IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE PU PURPLE BL BLUE RATING OF AT LEAST 105'C.USE COPPER CONDUCTORS ONLY. GR GREEN GY GRAY 4.BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE BK BLACK RD RED CORRECT COOLING CFM.(SEE SPEC SHEET FOR AIR FLOW CHART) 5.UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C.AND LOCAL CODES. 6.TO RECALL THE LAST 5 FAULTS,MOST RECENT TO LEAST RECENT,DEPRESS SWITCH 0140F00662 REV.A FOR MORE THAN 2 SECONDS WHILE IN STANDBY(NO THERMOSTAT INPUTS). 10 www.goodmanmfg.com SS-GMH8 1 ACCESSORIES MODEL 040 1.1 1614: 1:1 0:14: 1:1 00 1 . 40 . LPM-06 LP Conversion Kit(Springs&Orifice)' V V V V V V V V V HANG20 High-Altitude Natural Gas Kit(4500+ft) V V V V V V V V V FTK04 Twinning Kit V V V V V V V V V MVK-012 Masonry Vent Kits V V V V V V V MVK-022 Masonry Vent Kits V V AFE18-60A Fossil Fuel Kit V V V V V V V V V ' Honeywell or White-Rodgers valves 2 Upflow applications only MODELDESCRIPTION 4 1.1 1:14 11 LPM-06 LP Conversion Kit(Springs&Orifice)' V V V V HANG20 High-Altitude Natural Gas Kit(4500+ft) V V V V FTK04 Twinning Kit V V V V AFE18-60A Fossil Fuel Kit V V V V SBT14/17/21* DownflowSub-base V V V V I Honeywell or White-Rodgers valves GMH8 MINIMUM FILTER SIZES .. Filter Size(in2) (1)16 x 25(Side)or (1)16 x 25(Side or Bottom) (1)16 x 25 (2)16 x 25(Side)or (2)16 x 25(Side)or (1)14 x 24(Bottom) (Side or Bottom)' (1)20 x 25(Bottom) (1)24 X 24(Bottom) Note: Other size filters of equal or greater surface area maybe used;filters may also be centrally located. ' Use 2-16 x 25 filters on side returns or 20 x 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. GDHS MINIMUM FILTER SIZES MODEL . :141 . :0.0 . :1:14: . 11 Filter Size(in2) (2)10 x 20 or(1)14 x 25 Top Return (2)14 x 20 or (2)14 x 20 or (1)16 x 25 Top Return (1)20 x 25 Top Return Note:Other size filters of equal or greater surface area may be used;filters may also be centrally located. SS-GMH8 www.goodmanmfg.com 11 NorEs Goodman Manufacturing Company,L.P.,reserves the right to discontinue,or change at any time,specifications or designs without notice or without incurring obligations.02018 Goodman Manufacturing Company,L.P. • Houston,Texas • Printed in the USA. 12 www.goodmanmfg.com SS-GMH8 rch L&I ki �� iIndustries"' , Workplace Rights 0 Trades&Licensing Washington State Department of " Labor & Industries C M HEATING INC Owner or tradesperson 1415 BROADWAY EVERETT,WA 98201 Principals 425-259-0550 GARNER,JAMES NICHOLAS,PRESIDENT SNOHOMISH County GARNER,JAMES NICHOLAS,VICE PRESIDENT GARNER,KATHLEEN DIANE,SECRETARY GARNER,KATHLEEN DIANE,TREASURER GARNER,JAMES NICHOLAS,AGENT SMITH,PAMELA (End:01/01/1980) GARNER,PAUL MILTON,PRESIDENT (End: 10/01/2012) Doing business as C M HEATING INC WA UBI No. Business type 601 114 652 Corporation Governing persons JAMES GARNER PAUL M GARNER; KATHLEEN GARNER; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. CMHEAI"095R4 Effective—expiration 12/24/1991—05/03/2019 Bond CBIC $12,000.00 Bond account no. 655840 Received by L&I Effective date 04/24/2002 12/01/2001 Expiration date Until Canceled Insurance American Hallmark Ins Co of Te $1,000,000.00 Policy no. Help us improve 44CL603347 Received by L&I Effective date 04/24/2018 05/03/2018 Expiration date 05/03/2019 Insurance history Savings No o savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations Infraction no. PBATI01045 Satisfied Issue date RCW/WAC 05/16/2014 18.106.020 Violation city Violation amount MOUNTLAKE TERRACE $250.00 Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman,specialty or trainee certificate, temporary permit or medical gas endorsement as required.C M Heating employed Thomas Andrew Holden to perform plumbing installation work;Installed a new gas water heater,when not certified as a plumber as required. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 490,794-01 Doing business as CHIMNEY MASTERS Estimated workers reported Quarter 2 of Year 2018"31 to 50 Workers" L&I account contact T1/NICHOLE CAROW(360)902-5634-Email:CAN1235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/16/2015 No violations Inspection no. 317935327 Location 1415 Broadway Everett,WA 98201 Help us improve Raelynn Jones From: Debbie Bauers <debbie@cmheating.com> Sent: Monday, October 15, 2018 10:49 AM To: Raelynn Jones Subject: [External] - RE: 16419 40th DR NE Hi Raelynn, Yes, it is O Thank you. Debbie From: Raelynn ]ones [mailto:rjones@arlingtonwa.gov] Sent: Monday, October 15, 2018 10:19 AM To: debbie@cmheating.com Cc: Launa Peterson; Kristin Foster Subject: 16419 40th DR NE Good Morning Debbie, I am working on the mechanical permit for 16419 401h Dr NE. Is this a like for like change out? Please advise.Thank you! Sincerely, Raelynn Jones Permit Technician City of Arlington 238 N. Olympic Arlington, WA 98223 Office: 360-403-3436 www.arlingtonwa.sov 1 1 RESIDENTIAL MECHANICAL PERMIT APPLICATION t�N Department of Community & Economic Development City of Arlington • 18204 59th Ave NE • Arlington, WA 98223 • Phone (360) 403-3551 THIS APPLICATION IS TO BE USED WHEN APPLYING FOR NEW MECHANICAL INSTALLATION AND OR GAS PIPING FOR EXISTING RESIDENCES. PLEASE FILL OUT ALL PAGES OF THIS APPLICATION AND INCLUDE ALL INFORMATION. Project Address: 16419 40th DR NE, ARLINGTON 98223 Project Description:REPLACE GAS FURNACE Owner: SANDRA STANDORD Address. 16419 40TH DR NE City. ARLINGTON State.WA Zip Code: 98223 Phone. 360-322-0628 Email:ryansalexander@hotmail.com Applicant: C.M. HEATING INC Address: 1415 BROADWAY City. EVERETT State.WA Zip Code: 98201 Phone. 425-259-0550 Email: DEBBIE@CMHEATING.COM CONTRACTOR INFORMATION Contractor Name:C.M. HEATING INC Address: 1415 BROADWAY City. EVERETT State.WA Zip Code: 98201 License Number:CMHEAI*095R4 Expiration: 05/19 Phone: 425-259-0550 Email:DEBBIE@CMHEATING.COM STAFF USE ONLY Permit #: Accepted by: Date: 6/16LP Page 1 of 2 Y. RESIDENTIAL MECHANICAL PERMIT APPLICATION SING Department of Community& Economic Development City of Arlington • 18204 59th Ave NE• Arlington, WA 98223• Phone(360) 403-3551 SELECT ALL PROPOSED APPLIANCES Furnace (80+) Model #GDH80603AX AFUE80% ❑ Heat Pump Model # AFUE HSPE ❑ AC Unit Model # SEER ❑ Freestanding Stove ❑ Fire Place Insert ❑ Outdoor BBQ ❑ Gas Piping ❑ Solid-Fuel Appliance ❑ Other Gas Piping Information Not Applicable: ❑ Pipe Material: Pipe Size: Distance from Meter to Furthest Appliance: Total BTU's of all Appliances: • New gas piping requires a pressure test hooking to any appliance • Sediment traps (drips) are required on all gas lines • Gas lines are required to be supported/secured every 6 to 8 feet • Proper Combustion air and venting required for all appliances • A shut-off valve is required within 6 feet of all appliances Liz) � Applicant Signature: d5a513be"a92O�db81'b61e6' Date: 10/12/2018 Applicant Printed Name: Debbie Bauers I hereby certify that the above information is correct and that the construction, installation for the above mentioned property will be in accordance with the applicable laws of the City of Arlington and the State of Washington. 6/16LP Page 2 of 2 CITY OF ARLINGTON M 238 N. OLYMPIC AVE- ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:16419 40th DR NE Permit#:2210 Parcel#:00866800023000 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:Sandra Stanford Name:C.M.Heating Name:C.M.HEATING INC Address: 16419 40TH DR NE Address:1415 Broadway Address: 1415 BROADWAY City,State Zip:ARLINGTON,WA 98223-8449 City,State Zip:Everett,WA 98201 City,State Zip:EVERETT,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-6666 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:C.M.HEATING INC Name: Address: 1415 BROADWAY Address: City,State,Zip:EVERETT,WA 98201 City,State,Zip: Phone:425-259-6666 Phone: LIC#:CMHEAI*095R4 EXP. 05/03/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC110/IRC110. SALES TAX NOTICE: Sales tax relating to construction and construction materials in the City of Arl' g i;i st c nW on y sales tax return form a codcd Cily of ' gton#3101, Signs rc Print Name Date c ascd By Date CONDITIONS Approved as submitted. Inspection required. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/16/2018 Furnace $25.00 10/16/2018 Mechanical Permit Base Fee $25.00 10/16/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon ' CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 PHONE; (360) 403-3551 BUILDING PERMIT Address:16419 40th DR NE Permit#:2210 Parcel#:00866800023000 Valuation:0.00 OWNER APPLICANT CONTRACTOR Name:Sandra Stanford Name:C.M.Heating Name:C.M.HEATING INC Address: 16419 40TH DR NE Address:1415 Broadway Address: 1415 BROADWAY City,State Zip:ARLINGTON,WA 98223-8449 City,State Zip:Everett,WA 98201 City,State Zip:EVERETT,WA 98201 Phone: Phone:425-259-0550 Phone:425-259-6666 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name:C.M.HEATING INC Name: Address: 1415 BROADWAY Address: City,State,Zip:EVERETT,WA 98201 City,State,Zip: Phone:425-259-6666 Phone: LIC#:CMHEAI*095R4 EXP: 05/03/2019 LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Residential Mechanical CODE YEAR: 2015 STORIES: CONST.TYPE: DWELLING UNITS: I OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. IBC 110/IRC 110. SALES TAX NOTICE:Sales tax relating to construction and construction materials in the City of Arl' g t/ st ere ed on you sales tax return form and coded City of Arlington#3101. Signature Print Name Date c ased By Date CONDITIONS Approved as submitted. Inspection required. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 10/16/2018 Furnace $25.00 10/16/2018 Mechanical Permit Base Fee $25.00 10/16/2018 Processing/Technology Fee $25.00 Total Due: $75.00 Total Payment: $75.00 Balance Due: $0.00 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon GMH81GDH8Air Conditioning&Heating HEATING INPUT. 40,000-140,000 BTU/H TWO-STAGE CONVERTIBLE MULTI-SPEED GAS FURNACES 80%AFUE Contents Nomenclature........................................2 Product Specifications...........................3 Dimensions............................................5 Airflow Data...........................................7 Wiring Diagram....................................10 Accessories..........................................11 • Minimum Filter Sizes ..........................11 MEL— ism Standard Features Cabinet Features • Heavy-duty aluminized-steel dual- • Multi-position installation: diameter,tubular heat exchanger GMH8: upflow, horizontal left or right • Two-stage convertible gas valve GDH8:dedicated downflow automatically adjust to high or low stage • Convenient left or right connection • Durable Silicon Nitride igniter for gas and electrical service • Quiet single speed draft inducer • Cabinet air leakage(QLeak)<_2% • Self-diagnostic control board with constant memory fault code • Heavy-gauge steel cabinet with • Color-coded low-voltage terminals with provisions durable baked-enamel finish for electronic air cleaner and humidifier • Fully insulated heat exchanger • Multi-speed blower motor and blower section • Low continuous fan speed options offer quiet air circulation • California Low NOx emissions standards models available • For installation in California's South Coast Air Quality Management District(SCAQMD)only: This furnace does not meet the SCAQMD Rule 111114 ng/J NOx emission limit,and thus is subject to a mitigation fee of up to LIFETIME � 10 U N I T 10 PARTS HEAT EXCHANGER REPLACEMENT LIMITED LIMITED $450.This furnace is not eligible for the LI MITE O WARRANTY' YEAR WARRANTY- YEAR WARRANTY' SCAQMD Clean Air Furnace Rebate Fa COMPANYWITH COMPANY WITHL�/I,,�,�/_ QUALITY SYSTEM E C RONIED BY NV GL Program:www.CleanAirFurnaceRebate.com. .6)- CERTIFIEG6YGNVGL CERTIFIEGBYGNVGL • AHRI Certified; ETL Listed •��.a�� 50„RR,- * Complete warranty details available from your local dealer or at www.goodmanmfg. com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation.Online registration is not required in California or Quebec. SS-GMH8 www.goodmanmfg.com 9/18 Supersedes 5/17 NOMENCLATURE G M H 80 040 3 B X ** 1 2 4 5,6 7,8,9 10 11 12 13,14 BRAND F ENGINEERING G-Goodman"Brand Major/Minor Revisions CONFIGURATION M-Upflow/Horizontal NOx C-Downflow/Horizontal N-Natural Gas D-Dedicated Downflow X-Low NOx GAS VALVE H-Convertible Two-Stage,Single Phase CABINET WIDTH S-Single Stage,Single Speed A-14" C-21" B-17Y2" D-24%:" AFUE 80-80%AFUE MAximum CFM 3-1200 CFM MBTU/H 4-1600 CFM 040-40,000 BTU/h 100-100,000 BTU/h 5-2000 CFM 060-60,000 BTU/h 120-120,000 BTU/h 080-80,000 BTU/h 140-140,000 BTU/h 2 www.goodmanmfg.com SS-GMH8 PRODUCT SPECIFICATIONS - GMH8 HEATING CAPACITY Input 40,000 60,000 60,000 80,000 80,000 80,000 100,000 120,000 140,000 Natural Gas Output 32,000 48,000 48,000 64,000 64,000 64,000 80,000 96,000 112,000 LP Gas Output 32,000 48,000 48,000 64,000 64,000 64,000 80,000 96,000 96,000 AFUE' 80 80 80 80 80 80 80 80 80 Available AC @ 0.5"ESP 3 3 4 3 4 5 5 5 5 Temperature Rise Range(7) 25-55 20-50 20-50 35-65 35-65 35-65 35-65 40-70 40-70 CIRCULATOR BLOWER Size (D x W) 10"x 6" 10"x 6" 10"x 8" 10"x 8" 10"x 8" 10"x 10" 10"x 10" 11"x 10" 11"x 10" Horsepower @1075 RPM % % % % % % % % Speed 4 4 4 4 4 4 4 4 4 Vent Diameter Z 4" 4" 4" 4" 4" 4" 4" 4" 4" No.of Burners 2 3 3 4 4 4 5 6 6 ELECTRICAL DATA Min.Circuit Ampacity 3 4.8 4.8 8.8 4.8 8.8 8.8 8.8 14.7 14.7 Max.Overcurrent Device(amps)° 15 15 15 15 15 15 15 15 15 SHIP WEIGHT(LBS) 86 90 98 106 107 114 118 132 132 DOE AFUE based upon Isolated Combustion System(ICS) z Vent and combustion air diameters may vary depending upon vent length.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA B149.1 and CAN/CSA B142.2(in Canada). 3 Minimum Circuit Ampacity=(1.25 x Circulator Blower Amps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. 4 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply. • Gas Service Connection%"FPT • Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. SS-GMH8 www.goodmanmfg.com 3 PRODUCT SPECIFICATIONS - GDHS HEATING CAPACITY Input 40,000 60,000 80,000 100,000 Natural Gas Output 32,000 48,000 64,000 80,000 LP Gas Output 32,000 48,000 64,000 80,000 AFUE' 80 80 80 80 Available AC @ 0.5"ESP 25-55 30-60 35-65 40-70 Temperature Rise Range(°F) 3 3 4 5 CIRCULATOR BLOWER Size (DxW) 10X6 10X6 10X8 10X10 Horsepower @1075 RPM 1/3 1/3 1/2 3/4 Speed 4 4 4 4 Vent Diameter Z 4 4 4 4 No.of Burners 2 3 4 5 ELECTRICAL DATA Min.Circuit Ampacity 3 4.8 4.8 8.8 12.9 Max.Overcurrent Device(amps)° 15 15 15 15 SHIP WEIGHT(LBS) 88 92 106 114 DOE AFUE based upon Isolated Combustion System(ICS) z Vent and combustion air diameters may vary depending upon vent length.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA B149.1 and CAN/CSA B142.2(in Canada). 3 Minimum Circuit Ampacity=(1.25 x Circulator Blower Amps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ° Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC,60 Hz,single-phase electrical supply. • Gas Service Connection%"FPT • Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. 4 www.goodmanmfg.com SS-GMH8 GMH8 DIMENSIONS Alternate Gas Inlet Alt.Flue Outlet—Horizontal Left A 17/16' B 19%„ 33%" Alt.Gas Inlet 2U 235,6" Alt. High Voltage High-Voltage Inlet 0 13Y<<" 15" Low-Voltage Inlet �/ 1Alt.Low Voltage 28" 23" 7GMH80403A*B 14" 12Y2" GMH80805C*B 21" 19Yz" GMH80603A*B 14" 12Y2" GMH81005C*B 21" 19Yz" GMH80604B*B 17%" 16" GMH81205D*B 24%" 23" GMH80803B*B 17%" 16" GMH81405D*B 24%' 23" GMH8080413*13 17%" 16" Notes • Line voltage wiring and low-voltage wiring can enter through the right or left side of furnace. • Conversion kits for high-altitude(4500+ft)natural gas operation are available.Contact your Goodman distributor or dealer for details. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS SIDES REAR FRON-0 VENT 2 .• 1" 0" 3" 24"clearance for serviceability recommended. Single Wall Vent(SW)to be used only as a connector.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA 6149.1 and CAN/CSA B142.2(in Canada). Note:GMH8 approved for line contact in the horizontal position. SS-GMH8 www.goodmanmfg.com 5 GDH8 DIMENSIONS 4 28" 10 4 A 4 19%8 B High-Voltage " Electrical Low-Voltage Electrical O 00 Gas Inlet 33W 0 18%" o 0 0 0 0 0 MODEL • • FLOOR BASE GDH80403A*B 14" 12%" SBT14 GDH80603A*B 14" 12%" SBT14 GDH80804B*B 17'/=" 16" SBT17 GDH81005C*B 21" 19%" SBT21 NOTES • Line voltage wiring and low-voltage wiring can enter through the right or left side of furnace. • Conversion kits for high-altitude(4500+ft)natural gas operation are available.Contact your Goodman distributor or dealer for details. • Installer must supply the following gas line fittings,according to which entrance is used: 0 Left:One 909 street elbow;one 2%"pipe nipple;one 909 elbow;straight pipe;one ground joint union 0 Right:Straight pipe to reach gas valve MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS SIDES REAR FRONT' VENT2 .• SW B 1" 0" 3" 6" ' 24"clearance for serviceability recommended. 2 Single Wall Vent(SW)to be used only as a connector.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1(in the USA)and the Canada National Standard of Canada,CAN/CSA B149.1 and CAN/CSA B142.2(in Canada). Note:GMH8 approved for line contact in the horizontal position. 6 www.goodmanmfg.com SS-GMH8 GMH8 AIRFLOW DATA (CFM&TEMPERATURE RISE vs.EXTERNAL STATIC PRESSURE) EXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) SPEED 0Oi ®®®®®®®®®® CFM CFM CFM High 3 1,521 1,466 --- 1,414 --- 1,373 --- 1,298 --- 1,243 1,164 1,075 GMH8 Med 2.5 1,160 26 1,160 26 1,132 26 1,121 26 1,082 27 1,042 997 925 0403A*B Med-Lo 2 961 31 955 31 948 31 932 32 913 33 882 821 803 Low 1.5 781 38 785 38 781 38 773 38 761 32 745 716 668 High 3 1,422 31 1,352 33 1,307 34 1,197 37 1,157 38 1,092 1,075 983 GMH8 Med 2.5 1,098 40 1,081 41 1,051 42 1,039 43 1,021 44 983 924 868 0603A*B Med-Lo 2 919 48 913 49 892 50 847 ---- 829 ---- 818 792 728 Low 1.5 758 ---- 741 ---- 741 ---- 733 ---- 699 ---- 677 649 626 High 4 2,134 21 2,100 21 2,042 22 1,975 23 1,883 24 1,786 1,700 1,601 GMH8 Med 3.5 1,668 27 1,663 27 1,656 27 1,645 27 1,616 28 1,549 1,492 1,391 0604E*B Med-Lo 3 1,419 31 1,426 31 1,426 31 1,432 31 1,419 31 1,378 1,328 1,261 Low 2.5 1,134 39 1,145 39 1,166 38 1,171 38 1,160 38 1,144 1,111 1,071 High 3 1,607 37 1,572 38 1,547 39 1,498 40 1,448 41 1,390 1,302 1,222 GMH8 Med 2.5 1,159 51 1,156 51 1,145 52 1,127 53 1,108 53 1,075 1,033 957 0803E*B Med-Lo 2 938 63 916 65 916 65 900 ---- 889 ---- 86S 829 785 Low 1.5 785 ---- 766 ---- 743 ---- 730 ---- 709 ---- 683 666 604 High 4 2,051 ---- 1,983 ---- 1,895 --- 1,812 --- 1,725 --- 1,627 1,530 1,439 GMH8 Med 3.5 1,736 --- 1,708 35 1,652 36 1,611 37 1,540 38 1,475 1,394 1,307 0804E*B Med-Lo 3 1,493 35 1,668 36 1,459 41 1,429 41 1,389 43 1,339 1,274 1,204 Low 2.5 1,200 49 1,185 50 1,180 50 1,173 51 1,158 51 1,125 1,125 1,080 High 5 2,290 ---- 2,229 ---- 2,155 ---- 2,047 ---- 1,960 ---- 1,837 1,712 1,584 GMH8 Med 4 1,852 --- 1,820 --- 1,777 --- 1,719 --- 1,641 36 1,567 1,469 1,382 0805C*B Med-Lo 3.5 1,615 37 1,592 37 1,556 38 1,516 39 1,470 40 1,405 1,346 1,235 Low 3 1,290 46 1,285 46 1,265 47 1,235 48 1,214 49 1,174 1,044 904 High 5 2,323 --- 2,225 --- 2,120 35 2,040 36 1,974 38 1,801 1,688 1,577 GMH8 Med 4 1,858 40 1,847 40 1,799 41 1,744 42 1,674 44 1,577 1,493 1,399 1005C*B Med-Lo 3.5 1,596 46 1,587 47 1,571 47 1,552 48 1,493 50 1,397 1,326 1,217 Low 3 1,291 57 1,272 58 1,261 59 1,257 59 1,205 61 1,168 1,118 1,060 High 5 2,469 --- 2,389 --- 2,300 --- 2,223 40 2,131 42 2,027 1,902 1,786 GMH8 Med 4 1,575 56 1,558 57 1,545 58 1,513 59 1,500 59 1,419 1,354 1,271 1205D*B Med-Lo 3.5 1,402 63 1,380 64 1,343 66 1,319 67 1,296 69 1,245 1,183 1,106 Low 3 1,200 ---- 1,186 ---- 1,161 ---- 1,127 ---- 1,082 ---- 1,042 995 926 High 5 2,469 42 2,389 43 2,300 45 2,223 47 2,131 49 2,027 1,902 1,786 GMH8 Med 4 1,575 66 1,558 67 1,545 67 1,513 69 1,500 69 1,419 1,354 1,271 1405D*C Med-Lo 3.5 1,402 ---- 1,380 ---- 1,343 ---- 1,319 ---- 1,296 ---- 1,245 1,183 1,106 Low 1 3 1 1,200 1 1,186 1,161 1,127 1,082 1,042 1 995 1 926 @ 0.5"ESP NOTES • CFM in chart is without filter(s).Filters do not ship with this furnace,but must be provided by the installer.If the furnace requires two return filters,this chart assumes both filters are installed. • All furnaces ship as high-speed cooling and medium-speed heating.Installer must adjust blower cooling and heating speed as needed. • For most jabs,400 CFM per ton for cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • This chart is for information only. For satisfactory operation,external static pressure should not exceed value shown on the rating plate. • The dashed(----)areas indicate a temperature rise not recommended for this model. • At higher altitudes,a properly derated unit will have approximately the same temperature rise at a particular CFM,while ESP at the CFM will be lower. SS-GMH8 www.goodmanmfg.com 7 GDH8 AIRFLOW DATA (CFM&TEMPERATURE RISE vs.EXTERNAL STATIC PRESSURE) MODELEXTERNAL STATIC PRESSURE,(INCHES WATER COLUMN) MOTOR . r 0.2 �� 0.5 0.6 r SPEED AC' CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM High 3.0 1,353 --- 1,290 --- 1,246 --- 1,199 25 1,149 26 1,116 1,116 1,099 GDH8 Med 2.5 1,183 25 1,113 27 1,098 27 1,052 28 1,039 29 1,006 1,012 969 0403A*B (Med)2 Med-Lo 2.0 980 30 946 31 920 32 900 33 896 33 885 855 804 Low 1.5 778 38 762 39 738 40 746 40 738 40 717 696 678 High 3.0 1,290 34 1,236 36 1,194 37 1,166 38 1,176 38 1,166 1,108 1,029 GDH8 Med 2.5 1,139 39 1,090 41 1,035 43 1,063 42 1,063 42 1020 962 895 0603A*B (Med)2 Med-Lo 2.0 962 46 927 48 925 48 941 47 909 49 877 834 779 Low 1.5 787 56 776 57 763 58 744 60 723 --- 690 641 581 High 4.0 2,128 --- 2,063 --- 2,001 --- 1,927 --- 1,824 --- 1,726 1,628 1,529 GDH8 Med 3.5 1,840 --- 1,788 --- 1,745 --- 1,689 35 1,625 36 1,550 1,470 1,364 08046*B (Med)2 Med-Lo 3.0 1,602 37 1,558 38 1,543 38 1,493 40 1,455 41 1,402 1,328 1,239 Low 2.5 1,277 46 1,252 47 1,244 48 1,229 48 1,214 49 1,179 1141 1079 High 5.0 2,405 --- 2,361 --- 2,250 --- 2,161 --- 2,037 36 1,937 1,808 1,689 GDH8 Med 4.0 1,880 39 1,838 40 1,794 41 1,734 43 1,677 44 1,568 1,510 1,401 1005C*B (Med)2 Med-Lo 3.5 1659 45 1,630 45 1,587 47 1,537 48 1,492 50 1,445 1,368 1,287 Low 3.0 1,472 50 1,454 51 1,404 53 1,366 54 1,326 56 1300 1228 1139 Heating speed as shipped z @ 0.5"ESP NOTES • CFM in chart is without filter(s).Filters do not ship with this furnace,but must be provided by the installer.If the furnace requires two return filters,this chart assumes both filters are installed. • All furnaces ship as high-speed cooling and medium-speed heating.Installer must adjust blower cooling and heating speed as needed. • For most jobs,400 CFM per ton for cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • This chart is for information only. For satisfactory operation,external static pressure should not exceed value shown on the rating plate. • The dashed(----)areas indicate a temperature rise not recommended for this model. • At higher altitudes,a properly derated unit will have approximately the same temperature rise at a particular CFM,while ESP at the CFM will be lower. 8 www.goodmanmfg.com SS-GMH8 TEMPERATURE RISE RANGE CHART O LO - O C) - �t x 0 ILL 0 - O U LL M O LL U Z OC I 0 x LL LL L L - m U - O p - N - D - � - � O a _ 2 � V _ W H \� LL - U O O Lu O O o - O Q O N p� 00 N X LY p N - _ 0 00 - o Lu Lu 0 O m 0 - H o - a oo _ C ~ a - 00 = O 0 - °' = O o - ti 00 - m 0 - 0 - LL - U - O o - (0 m - O Ln - O lill Hill Ill 1111 111111111 1111 11 O CD M CD CD CD CD CD CD 00 O W ti O LO t M N 3si� 3,dni d3dW31 SS-GMH8 www.goodmanmfg.com 9 WIRING DIAGRAM WARNING:DISCONNECT POWER BEFORE I-------- HUMIDIFIER -1 INTEGRATED SERVICING.WIRING TO UNIT MUST BE •--- CONTROL MODULE PROPERLY POLARIZED AND GROUNDED. I XFMR(6) GND 2 VC GND(8) HUMIDIFIER MVC(9) C2 GAS VALVE MVH(12) J I MVL(2) Mi i yH I ;�, ID BLOWER AUXILIARY I / PRESSURE LIMIT CONTROLS SWITCH C V SMIN 1N0 StC'o _� IPS(10) C NO G.c�2 aTSEC MODEAU I V TO PSO(4) 10 1 12 �O 'ot K�II MICRO I HLI(T) w / 8 9 WH BL y I IHLO(1) 6 5 m AUTO RESET FUSE m� p R PRIMARY 2 LIMIT \♦ SEE NOTE 6 R02(11) CONTROL _ AUXILIARY BR MITS INTEGRATED Z R01(5) CONTROL MODULE i MANUAL RESET ROLLOUT N +L+ LIMIT CONTROL(S) 3 FS XFMR(3) (SINGLE CONTROL ON SOME MODELS) a-22 i 24 VAC N O 40 VA a O O BL BR TRANSFORMERF+ RD J g XFMR-H 115VAC XFMR-N 2 O r0 FLAME SENSOR C O m A J O ::� FP N HOT SURFACE a IGNITER Qj xFMR-H LINE-H EAC-H I IGN IGN-N m w OPt A - Y Ommm ~ O AA C T Omi ID y t BK C IND I BLWR IND-N n O a z b0 O o C A N N o u �- BK ;FMI ? �Orp COOL- CIRCULATOR OIc BLWR CIR-N Ap p A O WH O NO -p BK ELECTRONIC�1_ O GR 15 PIN PLUG EAC-H AIR CLEANER / EAC a ON SOME MODELS �•--- I N� v BLOWER COMPARTMENT LINE-H LINE-N _ __________ U i BURNER COMPARTMENT JUNCTION BOX N �, C C DOOR SWITCH 24 VAC DOOR � 0 / N HUMIDIFIER SWITCH T T U N SWITCH LOCATED IN BLOWER I '^ COMPARTMENT ON SOME MODELS / I 0 a o .o c WARNING: I I U1 DISCONNECT POWE P YL PRESSURE vL BEFORE SERVICING. 6 I DISCONNECT PRIMARY LIMIT SWITCH WIRING TO UNIT I j R° MUST BE E vL PROPERLY I I m YLflijPOLARIZED I = 2 W AND GROUNDED. — BK L GND N BR Vi BL OVERCURRENT PROTECTION DEVICE z wH � BK PM C HI JUNCTION HOT 1 2 3 BOX Q cc SURFACE 2 STAGE - LINE-N IGNITER GAS VALVE (HONEY WELL) o- - GND PU - LINE H INDUCED DRAFT a BLOWER ( TO 116 VAC/1/60HZ p' PU POWER SUPPLY WITH FLAME OVERCURRENT PROTECTION SENSOR DEVICE ROLLOUT LIMITS T N b4 (SINGLE CONTROL ON SOME MODELS) 3 Y C D STEADY ON=NORMAL OPERATION L LOW VOLTAGE(24V) EQUIPMENT GND /'fj Q O ar OFF =CONTROL FAILURE 6 E � 1 1 FLASH = SYSTEM LOCKOUT RETRIES/RECYCLES EXCEEDED LOW VOLTAGE FIELD --- y c a ( ) FIELD GND u m yo 2 2 FLASHES=PRESSURE SWITCH STUCK CLOSED HI VOLTAGE(115V) 1 16 7' 3 3 FLASHES=PRESSURE SWITCH STUCK OPEN FIELD SPLICE m J HI VOLTAGE FIELD --- 4 4 FLASHES=OPEN HIGH LIMIT SWITCH(TEMP.) v p JUNCTION 3 5 5 FLASHES=FLAME SENSE WITHOUT GAS VALVE IGNITER �L W v 6 6 FLASHES=OPEN ROLLOUT OR OPEN FUSE TERMINAL -0- y 7 7 FLASHES=LOW FLAME SIGNAL INTERNAL TO SWITCH(PRESS.) 8 8 FLASHES=CHECK IGNITER OR IMPROPER GROUND INTEGRATED CONTROL OVERCURRENT � ,� .E c RAPID FLASHES=REVERSED 115 VAC POLARITYNERIFY GND PLUG CONNECTION -CIZF PROT.DEVICE v J NOTES: COLOR CODES: PK PINK 1.SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2.MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. YL YELLOW BR BROWN 3.IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE OR ORANGE WH WHITE REPLACED,IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE PU PURPLE BL BLUE RATING OF AT LEAST 105°C.USE COPPER CONDUCTORS ONLY. GR GREEN GY GRAY 4.BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE BK BLACK RD RED CORRECT COOLING CFM.(SEE SPEC SHEET FOR AIR FLOW CHART) 5.UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C.AND LOCAL CODES. 6.TO RECALL THE LAST 5 FAULTS,MOST RECENT TO LEAST RECENT,DEPRESS SWITCH 0140F00662 REV.A FOR MORE THAN 2 SECONDS WHILE IN STANDBY(NO THERMOSTAT INPUTS). 10 www.goodmanmfg.com SS-GMH8 ACCESSORIES MODELDESCRIPTION 141 1.1 1.143 181 1814: 181 11 1 • 41 • LPM-06 LP Conversion Kit(Springs&Orifice)' V V V V V V V V V HANG20 High-Altitude Natural Gas Kit(4500+ft) V V V V V V V V V FTK04 Twinning Kit V V V V V V V V V MVK-01Z Masonry Vent Kits V V V V V V V MVK-02Z Masonry Vent Kits V V AFE18-60A Fossil Fuel Kit V V V V V V V V V ' Honeywell or White-Rodgers valves z Upflow applications only MODEL DESCRIPTION GDH8 1 141 1.1 1814 11 LPM-06 LP Conversion Kit(Springs&Orifice)' V V V V HANG20 High-Altitude Natural Gas Kit(4500+ft) V V V V FTK04 Twinning Kit V V V V AFE18-60A Fossil Fuel Kit V V V V SBT 14/17/21* Downflow Sub-base V V V V ' Honeywell or White-Rodgers valves GMH8 MINIMUM FILTER SIZES MODEL 141 1.1 1.1� 1:1 1:1�: 1:1 11 1 . 41 • Filter Size(in (1)16 x 25(Side)7or (1)16 x 25(Side or Bottom) 11)16 x 25 (2)16 x 25(Side)or (2)16 x 25(Side)or (1)14 x 24(Botto (Side or Bottom)' (1)20 x 25(Bottom) (1)24 X 24(Bottom) Note: Other size filters of equal or greater surface area may be used;filters may also be centrally located. Use 2-16 x 25 filters on side returns or 20 x 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. GDH8 MINIMUM FILTER SIZES MODEL . :141 1 :1.1 1 :1:14: 1 11 Filter Size(in 2) (2)10 x 20 or(1)14 x 25 Top Return (2)14 x 20 or (2)14 x 20 or (1)16 x 25 Top Return (1)20 x 25 Top Return Note: Other size filters of equal or greater surface area may be used;filters may also be centrally located. SS-GMH8 www.goodmanmfg.com 11 NOTES Goodman Manufacturing Company,L.P.,reserves the right to discontinue,or change at any time,specifications or designs without notice or without incurring obligations.©2018 Goodman Manufacturing Company,L.P. • Houston,Texas • Printed in the USA. 12 www.goodmanmfg.com SS-GMH8 Permit#: 2210 Permit Date: 10/15/18 Permit Type: RESIDENTIAL MECHANICAL Project Name: CM Heating_16419 40th DR Applicant Name: C.M. Heating Applicant Address: 1415 Broadway Applicant, City, State, Zip: Everett,WA 98201 Contact: Debbie Phone: 425-259-0550 Email: debbie@cmheating.com Scope of Work: Replace gas furnace Valuation: 0.00 Square Feet: 0 Number of Stories: 0 Construction Type: Occupancy Group: ID Code: Permit Issued: 10/16/2018 Permit Expires: Form Permit Type: Status: COMPLETE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning 141 Single Family 00866800023000 16419 40TH DR NE Sandra Stanford Residence Condominium Detached Contractors Contractor Primary Contact Phone Address Contractor Type License License# C.M.HEATING INC 425-259-6666 1415 BROADWAY CONSTRUCTION CMHEAI*095R4 CONTRACTOR Fees Fee Description Notes Amount Forced Air Heat fee per Btu $25.00 Mechanical Base Permit Fee $25.00 Processing/Technology $25.00 Total $75.00 Attached Letters Date Letter Description 10/15/2018 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 10/15/2018 DEBBIE BAUERS 72214921 cc $75.00 Outstanding Balance $0.00 Notes Date Note Created By: 10/16/2018 Emailed permit for signature. Kristin Foster Uploaded Files Date File Name 10/16/2018 4050539-2210 Issued Permit.pdf 10/15/2018 4047348-2210 Plans.pdf 10/15/2018 4045573-2210 Apnlication.pdf