Loading...
HomeMy WebLinkAbout19406 68TH DRIVE NE_BLD2249_2026 GITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 - PHONE; (360) 403-3551 BUILDING PERMIT Address:19406 68th Dr NE Permit#:2249 Parcel#:31051400300200 Valuation:45000.00 OWNER APPLICANT CONTRACTOR Name:WESTERN FOREST PRODUCTS US LLC Name:Kara Eberle Name:JR ABBOTT CONSTRUCTION Address:800-1055 W GEORGIA STREET Address:200 West Mercer St.Ste 503 Address:3408 1ST AVENUE S City,State Zip:VANCOUVER,BC V6E3P3 City,State Zip:Seattle,WA 98119 City,State Zip:SEATTLE,WA 98124 Phone: Phone:206-395-7603 Phone:206-467-8500 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Addition CODE YEAR: 2015 STORIES: CONST.TYPE: II B DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF O UPANCY HAS BEEN GRANTED. 1BC110/IRC110. 7andcoded T T Sales tax relating onstruction and construction materials in the City of Arlington must be reported on your sales tax return form ity o i tott#3101. 7 . i. tUl Print Name Date Released By CONDITIONS Adhere to approved plans. Please call for final inspection. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 12/6/2018 Building Permit Fee $856.68 12/6/2018 Building Plan Review Fee $ 12/6/2018 Processing/Technology Fee 556.84 68 $25 56.00 12/6/2018 State Surcharge-Commercial $25.00 Total Due: $1,463.52 Total Payment: $0.00 Balance Due: $1,463.52 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon Permit Information Date 10/31/2018 Permit Number 2249 Project Name WFP Arlington Mill Renovation-Fire Separation Applicant Name Kara Eberle Applicant Address 200 West Mercer St.Ste 503 City,State,Zip Seattle,WA 98119 Contact Kara Eberle Phone 206-395-7603 Email karae@ctagroup.com Permit Type Commercial Addition Site Address 19406 68th Dr NE Valuation 45000.00 Status Applied Permit Issued Permit Expires Square Feet 169058 Type of Construction/Occupancy Load Commercial Addition Number of Stories 1 Proposed Use Fire Separation Assigned To Raelynn Jones Property Parcel Address Legal Owner Owner Phone Zoning 31051400300200 11940668TH DRIVE NE I IWESTERN FOREST PRODUCTS US LLC 1242 Sawmills&Planing Mills Contractors Contractor Name Primary Contact Phone Email Contractor Type License License# 1R ABBOTT CONSTRUCTION O.R.ABBOTT ?06-467-8500 CONTRACTOR it-abor&Industries .11RABBC1022JZ Review Date Type Description I Target Date Completed Date Assi ned To Status 10/31/2018 lCommercial Addition 11/7/2018 Ouilding Iln Review Fees Fee Description Notes Amount Building Permit Fee 322.10.00.00 $856.68 Building Plan Review Fee 345.83.00.00 $556.84 Process in fTech nology Fee 341.43.00.02 $25.00 State Surcharge-Commercial 386.00.01.00 $25.00 Total $1,463.52 Uploaded Files I Upload File Date I File Uploaded By S 10/31/2018 3:20:58 PM 12249 Structural C pdf Jo Raelynn x 10/31/2018 3:20:58 PM _2249 Application.pdf Jones,Raelynn x i f Y O� y COMMERCIAL REMODEL ��QljN�Sp� PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 Project Name/Tenant WFP Arlington Mill Renovation - Fire Separation Site Address 19406 68th Drive NE Bldg./Unit/Suite Primarily F-1 (Construction to separate F-1 IBC Construction Type I I B IBC Occupancy Type and A-2 Occupancies) Description of Use Lumber storage Main Bldg:153,203 SF Building Square Footage Building E:15,855 SF Number of Stories 1 Square Footage per Floor Will there be any installation, modification or removal of the following? (Check all that apply) ❑ Automatic fire extinguishing systems ❑ Compressed gas systems ❑ Fire alarm and detection systems ❑ Fire pumps ❑ Flammable and combustible liquids (tanks, piping etc...) ❑ Hazardous materials ❑ High piled/rack storage ❑ Industrial ovens/furnace ❑ Private fire hydrants ❑ Spraying or dipping operations ❑ Standpipe systems ❑ Temporary membrane structure,tents(>200sq ft)or canopies(>400 sq ft) Provide details on any of the above checked items: Installation,changes, modifications or removal of any of the above may require additional submittals, information,or permits during the plan review or construction process. I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-described property will be in-ccordance wit he laws, rules and regulation of the State of Washington Ap ants Signature ara Eberle, Cushing Terrell Architects Engineers October 30, 2018 Print Applicants Name Date FOR STAFF USE ONLY rt�` eceived 9��ILAO\_ �% "_ OCT 3 0 Permit# Acc y Amount Received Receipt# Date Received REV 2015 Page 7 of 7 _J << � i COMMERCIAL REMODEL ��ilNG�p� PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2) SETS OF CONSTRUCTION PLANS, TWO(2) SETS OF SPECIFICATIONS, TWO(2) SETS OF STRUCTURAL CALCULATIONS, ONE(1) SETS OF NREC ENERGY CODE APPLICATIONS AND ONE(1) OCCUPANTS'S STATEMENT OF INTENDED USE. Type of Permit: (4 Commercial Remodel ( ) Commercial Addition ( )Tenant Improvement Project Address: 19406 68th Drive NE Parcel lD#: 31051400300200 Project DescriptionWFP Arlington Mill Renovation - Fire SeparatioVlegal Description: SEC 14 TWP 31 RGE Project Valuation: $45,000 Owner: Western Forest Products US LLC Phone Number: N/A Address: 800-1055 W Georgia St. city: Vancouver State: BC Zip Code: V6E3P3 Canada Contact Person: Kara Eberle Phone Number: 206.395.7603 Cell Phone: 206.395.7603 E-mail: karae@ctagroup.com Address: 200 West Mercer St. Suite 503 city: Seattle State: WA zip code: 98119 Contractor: Abbott Construction Phone Number: N/A Address: 3408 1 St Ave S. city: Seattle State: WA zip code: 98134 Contractor's License Number: Expiration: Plumbing Contractor: Phone Number: Address: City: State: Zip Code Contractor's License Number:. Expiration: Mechanical Contractor: Phone Number: Address: City: State: Zip Code: Contractor's License Number: Expiration: REV 2015 Page 6 of 7 Gt�Y y - COMMERCIAL REMODEL y�L��G�o PERMIT APPLICATION Department of Community& Economic Development City of Arlington• 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 The building permit does not include any mechanical, electrical, plumbing or fire sprinkler/alarm work. These permits are issued separately. Mechanical, electrical, plumbing, or fire sprinkler/alarm permits require a separate permit application and may also require separate plan review. Please note that any tenant improvement work in a space that involves food handling or preparation requires Snohomish County Health District approval before the permit can be issued. You must provide the Permit Center a copy of the approval letter or the approved plans. Contact the Snohomish County Health District at(425)339-5250 with any questions or for more information. An intake appointment is required for all large Tenant Improvement Building Permit Applications. To determine if your project requires an intake appointment, to schedule an appointment or to ensure that you have the most current information, please contact the City of Arlington Permit Center at(360)403-3551 or by email to ced, arlingtonwa.gov Application by courier or mail will not be accepted. Incomplete applications will not be accepted. I acknowledge that all items designated as submittal requirements must accompany my Building Permit Application to be considered a complete submittal. REV 2015 Page 5 of 7 COMMERCIAL REMODEL y�llNclo PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 - Phone(360)403-3551 The following minimum information is required for your Commercial/Multi-Family Building Permit Application. Mark each box to designate that the information has been provided. Please submit this checklist as part of your submittal documents. Incomplete applications will not be accepted. ® One (1)City of Arlington Commercial/Multi-Family Permit Application (One (1)permit application per building or structure is required) ❑ One (1)City of Arlington Commercial/Multi-Family Submittal Requirements Form ® Two (2)Architectural Drawings ❑X Two (2) Structural Drawings ® Two (2)Structural Calculations ❑ One (1) Project Specification Manuals (if applicable) ❑ One (1) NREC Code Compliance Forms ❑ One (1)Special Inspection Requirements Forms ❑ One (1) Occupant's Statement of Intended Use Form Drawings shall be BOUND SEPARATELY BY TYPE, architectural, structural and landscape, and then ROLLED TOGETHER/N COMPLETE SETS> An intake appointment is required for all new Commercial or Multi-Family Building Permit Applications. To schedule an appointment please contact the City of Arlington Permit Center at(360) 403 3551 or by email to Pre App Appointment Request. acknowledge that all items designated above are included as part of this application. REV 2015 Page 1 of 7 Y 01, COMMERCIAL REMODEL NG�o� PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 A. FEES DUE AT TIME OF PERMIT ISSUANCE B. CODES The City of Arlington currently enforces the following: International Codes 1. 2015 International Building Code(IBC) 2. 2015 International Residential Code(IRC) 3. 2015 International Mechanical Code(IMC) 4. 2015 International Fuel Gas Code(IFGC) 5. 2015 International Fire Code(IFC) 6. 2015 International Plumbing Code(IPC) 7. 2015 International Property Maintenance Code(IPMC) 8. 2015 International Existing Property Code(IEBC) 9. 2015 Washington State Energy Code(WESC) 10. 2009 Accessible&Usable Buildings and Facilities(ICC/ANSI 1417.1) Washington State Amendments 1. WAC 51-50 Washington State Building Code 2. WAC 51-51 Washington State Residential Code 3. WAC 51-52 Washington State Mechanical Code 4. WAC 51-54 Washington State Fire Code 5. WAC 51-56&51-57 Washington State Plumbing Code and Standards 6. WAC 51-11 Washington State Energy Code 7. WAC 296-46B Electrical Safety Standards,Administration,and Installation C. CITY OF ARLINGTON DESIGN REQUIREMENTS Design Wind Speed: 85 miles per hour(Exposure C) Ground Snow Load: 25 pounds per square foot Seismic Zone: D2 Rainfall: 2 inches per hour for roof drainage design. Frost Line Depth: 12 inches Soil Bearing Capacity: 1,500 psf unless a Geo-Technical Report is provided. (IBC Table 1804.2&IRC R401.4.1) D. PLANS AND DRAWINGS Submit two(2)complete sets of drawings and plans. Drawings and plans must be submitted on minimum 18"X 24", or maximum 30"X 42"paper.All sheets are to be the same size and sequentially labeled. Plans are required to be clearly legible,with scaled dimensions, in indelible ink, blue line,or other professional media. Plans will not be accepted that are marked preliminary or not for construction,that have red lines,cut and paste details or those that have been altered after the design professional has signed the plans. Please Note:A separate submittal of plans is required for each building or structure. REV 2015 Page 2 of 7 c'V °f COMMERCIAL REMODEL �Ncso PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 DETAILED SUBMITTAL REQUIREMENTS Mark each box to designate that the information has been provided. Please submit this checklist as part of your submittal documents A. X❑ SITE PLAN - REQUIRED WITH ALL SUBMITTALS (May be included as part of the Architectural Drawing cover Sheet) 1. Drawing shall be prepared at scale not to exceed 1"=20 feet. 2. Show building outline and all exterior improvements. 3. Provide property legal description and show property lines. 4. Provide dimensions from the property lines to a minimum of two building corners(or two identifiable locations for irregular plan shapes). 5. Show building setbacks,easements and street access locations. 6. Indicate North direction. 7. Indicate finish floor elevation for the first level. 8. Provide topographical map of the existing grades and the proposed finished grades with maximum five feet elevation contour lines. 9. Show the location of all existing underground utilities,including water, sewer,gas and electrical. 10. Flood hazard areas,floodways,and design flood elevations as applicable. B. [X] ARCHITECTURAL DRAWINGS 1. ® Cover Sheet a) Building Information 1. Specify model code information. 2. Construction Type. 3. Number of stories and total height in feet. 4. Building square footage(per floor and total) 5. IBC Occupancy Type (show all types by floor and total). 6. Mixed-use ratio(if applicable) 7. Occupant load calculation(show by occupancy type and total) 8. List work to be performed under this permit b) Design Team Information 1. Design Professional in Responsible Charge 2. Architects 3. Structural Engineers 4. Owner 5. Developer 6. Any other Design Team Members 2. ® Floor Plan a) Plan view 1/8"minimum scale. Details a minimum'/-inch scale. b) Plans must show the entire tenant space. c) Specify the use of each room/area. d) Provide an occupant load calculation on the floor plan.(on every floor, in all rooms and spaces) e) Show ALL exits on the plans; include new,existing or eliminated. f) Show Barrier-Free information on the drawings. g) Show the location of all permanent rooms,walls and shafts. h) Note the uses in the adjacent tenant spaces, if applicable. i) Provide a door and door hardware schedule. j) Show the location of all new walls, doors,windows, etc. REV 2015 Page 3 of 7 y COMMERCIAL REMODEL • • PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 k) Provide details and assembly numbers for any fire resistive assemblies. 1) Indicate on the plans all rated walls,doors,windows and penetrations. m) Provide a legend that distinguishes existing walls,walls to be removed and new walls. 3. ❑ N/A Reflected Ceiling Plan a) Plan view 1/8"minimum scale. Details a minimum'/-inch scale. b) Provide ceiling construction details. c) Provide suspended ceiling details complying with IBC 803.9.1.1. Show seismic bracing details. d) Show the location of all emergency lighting and exit signage. e) Detail the seismic bracing of the fixtures. f) Include a lighting fixture schedule. 4. ® Framing Plan a) Specify the size,spacing, span and wood species or metal gage for all stud walls. b) Indicate all wall, beam and floor connections. c) Detail the seismic bracing for all walls. d) Include a stair section showing rise, run, landings, headroom,handrail and guardrail dimensions. 5. ❑N/A Storage Racks (if applicable) a) Structural calculations are required for seismic bracing of storage racks eight feet or greater in height. b) Eight feet or less,show a positive connection to floor or walls. NOTE: High pile storage shall meet the requirements of current International Building and Fire Codes. C. ❑ N/A SPECIAL INSPECTION 1. Where special inspection is required by IBC 1704,the registered design professional in responsible charge shall prepare a special inspection program that will be submitted to the City of Arlington and approved prior to issuance of the building permit to comply with IBC 106.1. D. ❑ N/A WASHINGTON STATE ENERGY CODE 1. One(1)completed Washington State Non-Residential Energy Code Envelope Summary forms. E. OCCUPANT'S STATEMENT OF INTENDED USE 1. The Occupant's Statement of Intended Use form shall be completely filled out and may require the submittal of a Hazardous Materials inventory Statement(HMIS). Contact the Arlington REV 2015 Page 4 of 7 rae.l L J WorkplaceHome fSimflol Contact Labor & Industries Safety&Health (0 Claims&Insurance 0 O Trades&Licensing c Washington State Department of Labor & Industries J R ABBOTT CONSTRUCTION INC Owner or tradesperson 34081 ST AVE S SUITE 101 Principals SEATTLE,WA 98134-1805 206-467-8500 NELSON,RONALD A,PRESIDENT KING County KLEIN,DOUGLAS J,PRESIDENT ■ SPRAGUE,ANDREW W,PRESIDENT ■ STEDMAN,TROY L,PRESIDENT ■ PRICE,MICHAEL W,PRESIDENT ■ SHALLEY,BRANNON E,PRESIDENT SEAMNA,MARK C,SECRETARY FRASER,RICHARD H (End:02/09/2017) ■ FRASER,GWEN F (End:02/09/2017) ■ ABBOTT,JOHN R,PRESIDENT (End:02/09/2017) ■ STRAND,TIMOTHY R,PRESIDENT (End:02/09/2017) ■ MCGOWAN,JOHN P,VICE PRESIDENT (End:02/09/2017) ■ NEWMAN,WENDY P,VICE PRESIDENT (End:02/09/2017) ABBOTT,DAWN E,SECRETARY (End:02109/2017) ROBERTSON,ROBERT M,TREASURER (End:02/09/2017) Doing business as J R ABBOTT CONSTRUCTION INC WA UBI No. Business type 600 479 123 Corporation Governing persons JOHN MCGOWAN MIKE PRICE; MARK SEAMAN; BRANNON SHALLEY; ANDY SPRAGUE; TROY STEDMAN; DOUGLAS JOSEPH KLEIN; RON NELSON; JOHN ABBOTT, WENDY NEWMAN; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Help us improve r � I Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. JRABBC1022JZ Effective—expiration 04/09/1998—03/01/2020 Bond LIBERTY MUTUAL INS CO $12,000.00 Bond account no. 023009859 Received by L&I Effective date 04/24/2006 04/01/2006 Expiration date Until Canceled Insurance Liberty Mutual Fire Insurance $1,000,000.00 Policy no. TB2Z91459332028 Received by L&I Effective date 05/30/2018 06/01/2018 Expiration date 06/01/2019 Insurance history Savings ......................... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&1 tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 458,011-00 Doing business as J R ABBOTT CONSTRUCTION INC Estimated workers reported Pending current quarter filing L&I account contact T5/MELISSA VEST(360)902-5613-Email:VESM235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 04/28/2017 No violations Inspection no. Help us improVe 317944774 Location 2200 South 16th Street Des Moines,WA 98198 Inspection results date 07/14/2016 No violations Inspection no. 317940586 Location 22704 SE 4th Street Sammamish,WA 98074 Inspection results date 10/30/2014 No violations Inspection no. 317608909 Location 380 Winslow Way E Bainbridge Island,WA 98110 Inspection results date 09/17/2014 No violations Inspection no. 317447456 Location 2420 N.Proctor St. Tacoma,WA 98406 Inspection results date 0 9/0 812 0 1 4 No violations Inspection no. 317420651 Location 14550 Interurban Ave S Tukwila,WA 98168 Inspection results date 04/02/2014 No violations Inspection no. 316974104 Location 23320 Hwy 99 Edmonds,WA 98026 lcccss Help us W�YlbElir111t00 Improve E r _ STRUCTURAL 1 ENGINEERS Engineers Northwest Inc.,P.S. WESTERN FOREST PRODUCTS MILL 19406 68T" Drive Northeast Arlington, WA 98233 STRUCTURAL CALCULATIONS FOR FIRE BARRIER OFFICE COPY OF ARLINGTON O ��rhAL F� BUILDING DEPARTMENT APPROVED DATE NO CHANGES AUTHORIZED UNLESS APPROVED BY THE BUILDING INSPECTOR 2015 International Building Code October 29, 2018 Received ENW# 18039000-6 OCT 3 0 ?018 9725 Third Avenue NE,Suite 207 Seattle,WA 98115 . 206,525.7560.fax 206.522.6698 www.engmeersnw.com 1 0/29120 1 8 Design Maps Summary Repor MUM 9esig:: Maps Summary Report ! User—Specified Input Report Title Arlington, WA ^lon Octobur 29, 2018 1 7: 9:54 U'R Auilding Code Reference Document 2012/2015 International Building Code (which utiii..-2s USGS hazard Data available in 20C,3) Site Coordinates 48.171991N, 122.137451W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III Stanwood V. e a IA t P op.r., STlt1.t61 �W15N YES ERVAAPN SUSAW BAY Arlington .� •Warm Beach 1 T44LstdGWN tR itfA1RipoRT - 4 'VLAW i RES(VVATFOV ! „Granits FArTs SGS-Provided Output SS = 1.064 g SMS = 1.143 g S, = 0.762 g SI = 0.414 g SMi = 0.656 g Spl = 0.438 g For information on how the SS and 51'values above have been calculated from probabilistic (risk-targeted) and deterministic ground motions in the dirdction of maximum horizontal response, please return to the application and select the"2009 NEHRP"building code reference document. ' NICER ResponseSpertrum Deskgn ResponseSpecirnm N-IS •ifl: !' "P, II;,() D,, I 1,4:c Ivl. 1h, .. _. .- �.4.0 r.F.e r. I-:i I-�� 1.l:- 1.Cu li" =­ PcPild,T{5iN 1 Pcrkod,T fsrQ lough thf5 lnfort-nation Is ca pr oduct o,f the U,S. (_cc4ogical yurvoy, tYI? '1I-QVlde no warranty; expl�ssed w-Imp lied, as to the :Uracy of the data conLalned the;'rein. This tool Is not a substitute for technlcM sub)ect-rna trot knowledge. https://prod0l-earthquake-cr.usgs.gov/designmaps/us/summary.php?template=minimal&latitude=48.17198911179904&longitude=-l22.1 3 74514471 96... 1!1 1 0/8120 1 8 ATC Hazards by Location A This is a beta release of the new ATC Hazards by Location welasite. Please contact us with feedback. LNTC Hazards by Location earch Information Address: 19406 68th Dr NE,Arlington,WA 98223,USA Coordinates: 48.1726531,-122.13859930000001 Timestarnp: 2018-10-09T00:20.36.166Z Hazard Type: Wind Map Results Nanaimoo Richmondo Surrey . _ r . 8ake(•5iic�1ua4riie Cui+II(O • CtatlunALEolcsl ., _ . 'jNn(ntiu;d Fuc.�� ViMor 151 ft (a .0 Seattler::;tl n.a'r,r•• spnuanr, Seattle �. ��}��a1,�a$mv r .WASHING7 ON .' 1t1 -:r_. ?�''�. •. Lh6Qt Lai. Map dol.,;-:01T Giro7 h: Text R0SIIitS ASCE 7-16 MRI 10-Year 68 mph MRI 25-Year 74 mph MRI 50-Year 79 mph MRI 100 Year _ 84 mph Risk Category I -_ 93 mph Risk Category II 98 mph Risk Category III _ 105 mph Risk Category IV 109 mph ASCE 7-10 MRI 10-Year 72 mph MRI25-Year 79 mph MRI 50-Year 85 mph MRI/00-Year 91 mph Risk Category 1 100 mph Risk Category II 110 mph https://hazards.atcouncil.arg/#/wind?address=19406%2068th%20Dr%20NE%2C%2OArlington%2C°/a20WA%2098223%2C`/`20USA&Iat=48.1726531... 112 ENWENGINEERs NORTHWEST, INC., P.S. - STRUCTURAL ENGINEERS �w,''�?�j� Lt 9725 THIRD Avr NE,Sung 207,SEATTLE,OVA 99115 (206)525--7560 FAX(206)522-6699 � pp PROJECT# f o*yw-F� PROJECI hTAUT-mv Ml:C.L-S , DATE Sum Ec,r ScwA rlRlk PJALI IUR SHEET—Or- By eD C�,7Avv : To pttx(oo FT-ft P..A-F RtiV-P- �0/ (-59-7kr 1 6 2 onJ4 v o ` VuL-r _ ENGINEERS-NORTHWEST,INC.P.S ' SHEET OF ` 9725 THIRD AVE N E (SITTE 207) SE4ll'LE,WA.98115 Property of Engineers Northwest. Inc.,P.S.- Use by others unlawful ASCE 7-10 Wind Loads per ASCE 7-10-Chapter 30-Components&Cladding-h 5 60'-0" Input Cells= Project Number: Project Name: Mill Arlington Location: �— Design By: Program Limitations: 'I. Building must be a low-rise building or 2. Building mean roof height does not exceed 60 feet. 3. Building is enclosed or partially enclosed. BUILDING AND SITE INFORMATION INPUT Building width,B= 98 It Building length,L= 150 ft Building eave height,he- 22 .� ft Building ridge height,h,= 25 _ it Height of parapet,hp= 24.5 It Roof slope,s= 00 In.!t =4,76 degrees Is roof a gable or hip= Gable Risk Category= II Wind velocity,V= 110 milhr = 85 mi/hr(ASD) Exposure= B Topographic factor,K21= q�- Wind directionality factor,Kd= 085 Bldg internal pressure condition= Part Enclosed Wall Effective Wind Area,EWA= +165 Roof Effective Wind Area,EWA= 200 ft-, OUTPUT Mean roof height,h= 22 ft a= 8.8 ft Internal Pressure Coeffs,GCPi= 0.55 -0.55 Pressure exposure coeff,KI,= 064 Velocity pressure,qh= 16.85 psf COMPONENTS AND CLADDING(C&C) p=gh[(GCP)-(GCp;)j(lb/ftr) Wind Pressures for Watts with h 5 60' *Note, Design wind pressures shall not be less than a net pressure of 16psf(tilt) acting in either direction normal to the surface. Wind Pressures Ac it Toward Surface Bldg Surface 4&5= 21.2 psf(LRFD)=12.7 psf(ASD) Wind Pressures Pressures Acting From SurfaCc3From SurfaCc3 Bldg Surface 4= -22.7 psf(LRFD)=-13.6 psf(ASD) Bldg Surface 5= -24 psf(LRFD)=-14.4 psf(ASD) I 5 k s 5 Copy of ASCE7-10 Wind Loads Low Rise xlsx C&C ENGINEERS-NORTHWEST,INC.P.S SHEET OF l 9725 THIRD AVE N E.(SUITE 207) SEATTLE.WA.98115 Wind Pressures_for Roofs(gable roofs.&hin roofs)with h 5 60' 'Note: Design wind pressures shall not be less than a net pressure of 16psf(uft) acting in either direction normal to the surface. Wind Pressures Acting Toward Surface Roof Surface 1,2&3= 12.6 psf(LRFD)=7.6 psf(ASD) Wind Pressures Actina Away From Surface Roof Surface 1 = -24A psf(LRFD)=-14.6 psf(ASD) Roof Surface 2= -27.8 psf(LRFD)=-16.7 psf(ASD) Roof Surface 3= -27.8 psf(LRFD)=-16.7 psf(ASD) Wind Pressures Actina Away From Surface(Overhang Roof Surface 1 = -23.3 psf(LRFD)=-14 psf(ASD) Roof Surface 2= -23.3 psf(LRFD)=-14 psf(ASD) Roof Surface 3= -13.5 psf(LRFD)=-8.1 psf(ASD) i r i t � I r I t H Ui (D lr i I t 1 r r t I 1 — 2- -- -2 _r3 .5. IN ptuapct apttll to of I,ikhur than 3 ft(0-9m)is provided around tht perimeter of•the roo'Nviih 6 r 7". the negative values of GIC,,in Zone 3 shall be equal to those lb)%aue 2 autl posilivc Valne:or(;('p in Zones 3 and 3 shall Iw set t:qual to those for]n+liLtsnes 4 ruttE S resprctivety in Fir;nic.3liA-I. Wind Pressures for Parataets faabfe roofs.8 hf0 roofs)w/th h 5 60' "Note: Design wind pressures shall not be less than a net pressure of 16psf(ult) acting in either direction normal to the surface pp=q,[(GC.)-(GC,,)](lb/ft') Velocity pressure,qN= 17.38 psf Parapet Load Case A Wind load @ corner,p.= 31 A psf(LRFD)=18.8 psf(ASD) Wind load not @ comer,pp= 31.4 psf(LRFD)=18.8 psf(ASD) lie �ryJ''��1 Parapet Load Case B �� Jai/ Wind load @ corner,p4= 27.5 psf(LRFD)=16.5 psf(ASD) Wind load not @ corner,pp= 26.1 psf(LRFD)=15.7 psf(ASD) Windward pniapet Iceward pampet Load Case A Lund Case n Tap aY'parapet -i,30e• — -_;rq F.'B,l .l -,7, .bi rvtYFX .']1•A .� I 4.'1•ie'Nal �'L•�lea�i,e`Nat: A!�u'� fAe3ulivc 4Va11 .l,u u ypr�6! >�'Y Y.w1Al! �y nnnA4S ht, Copy of ASCE7-10 Wind Loads Low Risexlsx C&C ENWENGINEERs NORTHWEST', INC., P.S. - STRUCTURAL ENGINEERS 9725 THIRD AVE NE,SUITE 207,SFAI"I LE,WA 98115 (206)525--7560 Fax(206)522-6698 PRojEc-r# PROJEc~r DATF SUBJECT SHEF,T OF BY S�xSrwst dos To ( c� &A" ZO r Liu L 9v7�x I .2o Z57 zp ems' Project Name: New WorkSpace Page 1 of 1 Model: Beam/Stud—1 Date: 10/15/2018 Code: 2012 NASPEC[AISI S100-2012] Simpson Strong-Tie®CFS Designer'"2.5.3.0 raxobection: (2)600S162-54(50 ksi)Back-To-Back C Stud = 5054.2 Ft-Lb Va= 5645.8 lb I= 5.72 in^4 Loads have not been modified for strength checks Loads have not been modified for deflection calculations 2.50 20.00 N• Bridging Connectors-Design Method=AISI S100 Simpson Strong-Tie Span/CantiLever Bridging Connector Stress Ratio Span N/A Top CantiLever N/A - Shear and Web Crippling Checks Bending and Shear(Unstiffened): 3.6% Stressed @R2 25.00 15.00 Bending and Shear(Stiffened): NA Web Stiffeners Required?: No Simpson Strong-Tie Connectors Connector Anchor Support Rx(lb) Ry(lb) Simpson Strong-Tie Connector Interaction Interaction R1 185 0 FC643.5 Min(4#12-14)&(4)#12 SST X to A36 Steel 18.97% 11.64% R2 240 0 SCB45.5(2)&(2)#12 SST X to A36 Steel 31.58% 30.19% Reference Catalog for connector and anchor requirement notes as well as screw placements requirement Flexural and Deflection Check Mmax Mmax/ Mpos Bracing Ma(Brc) Mpos/ Deflection Span Ft-Lb Maxo Ft-Lb (in) Ft-Lb Ma(Brc) (in) Ratio Span 1140.8 0.226 1140.8 Full 5054.2 0.226 0.756 U397 Top CantiLever 62.5 0.012 39.9 None 4625.7 0.009 0.236 L/255 Distortional Buckling Check Span K-phi Lm Brac Ma-d Mmax/ lb-inlin in Ft-Lb Ma-d Span 0.00 300.0 4316.7 0.264 Top CantiLever 0.00 30.0 4316.7 0.014 SIMPSON STRONG-TIE COMPANY INC. www.strongtie.com Project Name: New WorkSpace Page 1 of 1 Model: Beam/Stud—1 Date:1 011 5/2 0 1 8 Code: 2012 NASPEC fAISI S100-20121 Simpson Strong-TieRO CFS DesignerT°2.5.3.0 Section: 600S162-54(50 ksi)Single C Stud Maxo= 2527.1 Ft-Lb Va= 2822.9 lb I= 2.86 in"4 Loads have not been modified for strength checks N® Loads have not been modified for deflection calculations Bridging Connectors-Design Method=AISI S100 Simpson Strong-Tie Span/CantiLever Bridging Connector Stress Ratio Span N/A Shear and Web Crippling Checks Bending and Shear(Unstiffened): 5.3% Stressed @R1 20.00 i.i 15.00 Bending and Shear(Stiffened): NA Web Stiffeners Required?: No Simpson Strong-Tie Connectors Connector Anchor Support Rx(lb) Ry(lb) Simpson Strong-Tie Connector Interaction Interaction R1 150 0 FCB43.5 Min(4#12-14)&(4)#12 SST X to A36 Steel 15.38% 9.43% R2 150 0 SCB45.5(2)&(2)#12 SST X to A36 Steel 19.74% 18.87% Reference catalog for connector and anchor requirement notes as well as screw placements requirement Flexural and Deflection Check Mmax Mmaxl Mpos Bracing Ma(Brc) Mposl Deflection Span Ft-Lb Maxo Ft-Lb (in) Ft-Lb Ma(Brc) (in) Ratio Span 750.0 0.297 750.0 Full 2527.1 0.297 0.640 L/375 Distortional Buckling Check Span K-phi Lm Brac Ma-d Mmaxt lb-inlin in Ft-Lb Ma-d Span 0.00 240.0 2158.3 0.347 SIMPSON STRONG-TIE COMPANY INC, www.strongtia.com I ENWENGINEERs NORTHWEST, INC., P.S. — STRUCTURAL ENGINEERS 9725 TI[1RD Avr•.NE,Sui iE 207,SEATTLr,WA 99115 (206)525---7560 FAX(206)522-6698 PROJECT# PROJECT- - _ DATE SUBJECT SIILET OF -- �_ By (Ax- . Title Block Line 1 Project Title: Q You can change this area E;gineer: using the"Settings"menu item Project ID: and then using the"Printing& Project Descr: Title Block"selection. Title Block Line 6 Printed:29 0CT 2018, 2 4;PM Steel Beam -- -- -- - File-C1U"mVichz0D-Mop111%6 Software cMrx}htENERCALC,INC 1983 7018.Budd 10 18 9 30 0:6-0: Description: --None- CODE REFERENCES___ _ Calculations per AISC 360-10, IBC 2015, CBC 2016,ASCE 7-10 Load Combination Set:ASCE 7-16 Material Properties Analysis Method: Allowable Strength Design Fy:Steel Yield: 36.0 ksi Beam Bracing: Completely Unbraced E:Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending .h Span=30.0 ft -Applied Loads Service loads entered Load Factors will be applied for calculations Beam self weight NOT internally calculated and added Uniform Load: D=0.0050, Lr=0.0250 k/ft, Tributary Width=10 ft DESIGN SUMMARY _ - • Maximum Bending Stress Ratio = 0.730. 1 Maximum Shear Stress-Ratio= 0.014 : 1 Section used for this span C8x13.75 Section used for this span C8x13.75 Ma:Applied 3.375 k-ft Va:Applied 0.450 k Mn/Omega:Allowable 4.623 k-ft Vn/Omega:Allowable 31.352 k Load Combination +D4Lr+H Load Combination +D+Lr+H Location of maximum on span 15 000ft Location of maximum on span 0.000 ft Span#where maximum occurs Span#1 Span#where maximum occurs Span#1 ' Maximum Deflection iMax Downward Transient Deflection 0.437 in Ratio= 823>=360 Max Upward Transient Deflection 0.000 in Ratio= 0 <360 Max Downward Total Deflection 0.525 in Ratio= 686>=180 Max Upward Total Deflection 0.000 In Ratio= 0<1$0 Maximum Forces &Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values _ _ Sufmwiy of Shear Values Segment Length Span# M V Mmax+ Mmax- Ma Max Mnx Mnx/Omega Cb Rm Va Max Vnx VnxlOmega +D+H - - ---- - - Dsgn.L= 30.00 ft 1 0.122 0.002 0.56 0.56 7.72 4.62 1.14 1.00 0.08 52.36 31,35 +D+L+H Dsgn.L= 30.00 ft 1 0.122 0.002 0.56 0.56 7.72 4.62 1.14 1.00 0.08 52.36 31.35 +D+Lr4H Dsgn.L= 30.00 ft 1 0.730 0.014 3.38 3.38 7.72 4.62 1.14 1.00 0.45 52.36 31.35 +D+S+H Dsgn.L= 30.00 It 1 0.122 0.002 0.56 0.56 7.72 4.62 1.14 1.00 0.08 52.36 31.35 +D+0.750Lr+0.750L+H Dsgn.L= 30.00 ft 1 0.578 0.011 2.67 2.67 7.72 4.62 114 100 0.36 52.36 31.35 +D+0.750L+0.750S+H Dsgn.L= 30.00 ft 1 0.122 0.002 0.56 0.56 7.72 4.62 1.14 1.00 0.08 52.36 31.35 +D+0.60W+H Dsgn.L= 30.0011 1 0.122 0.002 0.56 0.56 7.72 4.62 1.14 1.00 0.08 52.36 31.35 +D+0.750Lr,0.450W+H Dsgn.L= 30.00 ft 1 0.578 0.011 2.67 2.67 7.72 4.62 1.14 1.00 0.36 52.36 31.35 - +0.750S+0.450W+H Dsgn.L= 30.00 ft 1 0.122 0.002 0.56 0.56 7.72 4.62 1.14 1.00 0.08 52.36 31.35 +0.60D+0.60W+0,60H Dsgn.L= 30.00 ft 1 0.073 0.001 0.34 0.34 7.72 4.62 1.14 1.00 0.05 52.36 31.35 +D+0.70E+0.601­1 Dsgn.L= 30.00 ft 1 0.122 0 002 0.56 0,56 7.72 4.62 1.14 1.00 0.08 52.36 31.35 +D+0.750L+0.750 S+0.5250 E+H Dsgn.L= 30.00 ft 1 0.122 0.002 0.56 0.56 7.72 462 114 100 0.08 52.36 31,35 Title Block Line 1 Project Title: You can change this area Engineer: p using the"Settings"menu item Project ID: and then using the"Printing& Project Descr: Title Block'selection. Title Block Line 6 Printed:29 OCT 2018, 2:47PM File=C VJws1nt WesWp111 eW Steel Beam -- Sauarpo"n htENERCAU:,INC 1902010.Build 10 18 930 r:rr: Description; -None- Load Combination Max Stress Ratios _ Summary of Moment Values Summary of Shear Values Segment Length Span# M V Mmax+ Mmax- Ma Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega +0 60D+0.70E+H - -- - -- Dsgn.L= 30.00 ft 1 0.073 0.001 0.34 0.34 7.72 4.62 1.14 1.00 0.05 52.36 31.35 Overall Maximum Deflections Load Combination Span Max.""Deft Location in Span Load Combination Max.'+"DeFl Location in Span +D+Lr+H 1 0.5246 15 086 D 0000 0.000 Vertical Reactions Support notation:Far left is#1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.450 0.450 w Overall MINimum 0.045 0.045 +D+H 0.075 0.075 +D+L+H 0.075 0.075 +D+Lr+H 0.450 0.450 +D+S+H 0.075 0.075 -DA.750Lr+0.750L+H 0.356 0.356 +D+0.750L+0.750S+H 0.075 0.075 +D+0.60W+H 0.075 0.075 +D+0.750Lr+0.450W+H 0.356 0.356 +D+0.750S+0.450W+H 0.075 0.075 A.60D+D.60W+0.60H 0.045 0.045 +0+0.70E+0.60H 0.075 0.075 +D+0.750L+0.750S+0.5250E+H 0.075 0.075 +0.60D+070E4H 0.045 0.045 D Only 0.075 0.075 Lr Only 0.375 0.375 L Only S Only W Only E Only H Only NOTICE ' x TO PERMITEE AND/OR OWNER Cl PARTIAL APPROVAL Cl CORRECTIONS REQUIRED ❑ DO NOT OCCUPY )fAPPROVED PERMIT#: LO_T#: DATE: 1 2-- .(Lt), 16 JOB ADDRESS: L I' '_ TYPE OF INSPECTION: %L ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK:MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION:$50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BY LAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE /BUILDING DEPT. Cl PLANNING DEPT. CITY OF ARLINGTON N 0 T I C E TO PERMITEE AND/OR OWNER ❑ PARTIAL APPROVAL ❑ CORRECTIONS REQUIRED ❑ DO NOT OCCUPY XAPPROVED PERMIT#: Z. LOT#: DATE: .� i JOB ADDRESS: L ' TYPE OF INSPECTION: I ❑ NO PERMIT-STOP WORK-OBTAIN PERMIT:AND MAKE WORK COMPLY WITH CURRENT BUILDING AND/OR PLANNING CODES. ❑ CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT -STOP WORK: MAKE EXISTING WORK COMPLY WITH APPROVED PLAN AND PERMIT OR REMOVE IT. ❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY INSPECTOR. ❑ CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. ❑ WORK NOT READY FOR INSPECTION: $50 REINSPECTION FEE(PER IBC) MUST BE PAID PRIOR TO NEXT INSPECTION. ❑ CONTACT INSPECTOR 360-403-3551 ❑ CALL FOR REINSPECTION z�- THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN DAYS OR PENALTIES IMPOSED BYLAW MAYAPPLY. FOR INSPECTION CALL: 360-403-3417 INSPECTOR DATE /BUILDING DEPT. a PLANNING DEPT. CITY OF ARLINGTON COMMERCIAL REMODEL IN o� PERMIT APPLICATION Department of Community$ Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 Project Name/Tenant WFP Arlington Mill Renovation - Fire Separation Site Address 19406 68th Drive NE Bldg./Unit/Suite Primarily F-1 (Construction to separate F-1 IBC Construction Type II B IBC Occupancy Type and A-2 Occupancies) Description of Use Lumber storage Main Bldg:153,203 SF Building Square Footage Building E:15,855 SF Number of Stories 1 Square Footage per Floor Will there be any installation, modification or removal of the following? (Check all that apply) ❑ Automatic fire extinguishing systems ❑ Compressed gas systems ❑ Fire alarm and detection systems ❑ Fire pumps ❑ Flammable and combustible liquids(tanks, piping etc...) ❑ Hazardous materials ❑ High piled/rack storage ❑ Industrial ovens/furnace ❑ Private fire hydrants ❑ Spraying or dipping operations ❑ Standpipe systems ❑ Temporary membrane structure,tents(>200sq ft)or canopies (>400 sq ft) Provide details on any of the above checked items: Installation,changes, modifications or removal of any of the above may require additional submittals, information,or permits during the plan review or construction process. I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above-described property will be in ccordance wil he laws, rules and regulation of the State of Washington. Ap ants Signature ara Eberle, Cushing Terrell Architects Engineers October 30, 2018 Print Applicants Name Date )� FOR STAFF USE ONLY Permit# Acc y Amount Received Receipt# Date Received REV 2015 Page 7 of 7 i � i t ��. , � Y D+t' COMMERCIAL REMODEL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 THIS APPLICATION MUST BE ACCOMPANIED BY TWO(2) SETS OF CONSTRUCTION PLANS, TWO(2) SETS OF SPECIFICATIONS, TWO(2) SETS OF STRUCTURAL CALCULATIONS, ONE(1) SETS OF NREC ENERGY CODE APPLICATIONS AND ONE(1) OCCUPANTS'S STATEMENT OF INTENDED USE. Type of Permit: (X) Commercial Remodel ( ) Commercial Addition ( )Tenant Improvement Project Address: 19406 68th Drive NE Parcel lD#: 31051400300200 Project DescriptionWFP Arlington Mill Renovation - Fire Separatio0legal Description: SEC 14 TWP 31 RGE Project Valuation: $45,000 Owner: Western Forest Products US LLC Phone Number: N/A Address: 800-1055 W Georgia St. city. Vancouver State: BC Zip Code: V6E3P3 Canada Contact Person: Kara Eberle Phone Number: 206.395.7603 Cell Phone: 206.395.7603 E-mail: karae@ctagroup.com Address: 200 West Mercer St. Suite 503 city: Seattle State: WA Zip Code: 98119 Contractor: Abbott Construction Phone Number: N/A Address: 3408 1 St Ave S. city:. Seattle State: WA Zip Code: 98134 Contractor's License Number: Expiration: Plumbing Contractor: Phone Number: Address: City: State: Zip Code: Contractor's License Number: Expiration: Mechanical Contractor: Phone Number: Address: City:_ State: Zip Code: Contractor's License Number: Expiration: REV 2015 Page 6 of 7 L1�y COMMERCIAL REMODEL �•pLjNG p� PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 The building permit does not include any mechanical, electrical, plumbing or fire sprinkler/alarm work. These permits are issued separately. Mechanical, electrical, plumbing, or fire sprinkler/alarm permits require a separate permit application and may also require separate plan review. Please note that any tenant improvement work in a space that involves food handling or preparation requires Snohomish County Health District approval before the permit can be issued. You must provide the Permit Center a copy of the approval letter or the approved plans. Contact the Snohomish County Health District at(425) 339-5250 with any questions or for more information. An intake appointment is required for all large Tenant Improvement Building Permit Applications. To determine if your project requires an intake appointment, to schedule an appointment or to ensure that you have the most current information, please contact the City of Arlington Permit Center at(360)403-3551 or by email to ced(a�,arlingtonwa.clov Application by courier or mail will not be accepted. Incomplete applications will not be accepted. I acknowledge that all items designated as submittal requirements must accompany my Building Permit Application to be considered a complete submittal. REV 2015 Page 5 of 7 Y U� COMMERCIAL REMODEL PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 The following minimum information is required for your Commercial/Multi-Family Building Permit Application. Mark each box to designate that the information has been provided. Please submit this checklist as part of your submittal documents. Incomplete applications will not be accepted. ® One(1)City of Arlington Commercial/Multi-Family Permit Application (One (1)permit application per building or structure is required) ❑ One (1)City of Arlington Commercial/Multi-Family Submittal Requirements Form ® Two (2)Architectural Drawings ❑X Two(2)Structural Drawings ® Two (2)Structural Calculations ❑ One(1) Project Specification Manuals (if applicable) ❑ One (1) NREC Code Compliance Forms ❑ One (1) Special Inspection Requirements Forms ❑ One (1)Occupant's Statement of Intended Use Form Drawings shall be BOUND SEPARATELY BY TYPE, architectural, structural and landscape, and then ROLLED TOGETHER IN COMPLETE SETS> An intake appointment is required for all new Commercial or Multi-Family Building Permit Applications. To schedule an appointment please contact the City of Arlington Permit Center at(360) 403 3551 or by email to Pre App Appointment Request. I acknowledge that all items designated above are included as part of this application. REV 2015 Page 1 of 7 Gt�Y 01' COMMERCIAL REMODEL • ING�p� PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 A. FEES DUE AT TIME OF PERMIT ISSUANCE B. CODES The City of Arlington currently enforces the following. International Codes 1. 2015 International Building Code(IBC) 2. 2015 International Residential Code(IRC) 3. 2015 International Mechanical Code(IMC) 4. 2015 International Fuel Gas Code(IFGC) 5. 2015 International Fire Code(IFC) 6. 2015 International Plumbing Code (IPC) 7. 2015 International Property Maintenance Code(IPMC) 8. 2015 International Existing Property Code(IEBC) 9. 2015 Washington State Energy Code(WESC) 10. 2009 Accessible&Usable Buildings and Facilities(ICC/ANSI 1417.1) Washington State Amendments 1. WAC 51-50 Washington State Building Code 2. WAC 51-51 Washington State Residential Code 3. WAC 51-52 Washington State Mechanical Code 4. WAC 51-54 Washington State Fire Code 5. WAC 51-56&51-57 Washington State Plumbing Code and Standards 6. WAC 51-11 Washington State Energy Code 7. WAC 296-46B Electrical Safety Standards,Administration,and Installation C. CITY OF ARLINGTON DESIGN REQUIREMENTS Design Wind Speed: 85 miles per hour(Exposure C) Ground Snow Load: 25 pounds per square foot Seismic Zone: D2 Rainfall: 2 inches per hour for roof drainage design. Frost Line Depth: 12 inches Soil Bearing Capacity: 1,500 psf unless a Geo-Technical Report is provided. (IBC Table 1804.2&IRC R401.4.1) D. PLANS AND DRAWINGS Submit two(2)complete sets of drawings and plans. Drawings and plans must be submitted on minimum 18"X 24",or maximum 30"X 42"paper.All sheets are to be the same size and sequentially labeled. Plans are required to be clearly legible,with scaled dimensions, in indelible ink, blue line,or other professional media. Plans will not be accepted that are marked preliminary or not for construction,that have red lines, cut and paste details or those that have been altered after the design professional has signed the plans. Please Note:A separate submittal of plans is required for each building or structure. REV 2015 Page 2 of 7 Y U� COMMERCIAL REMODEL �'AlING,�O� PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone(360)403-3551 DETAILED SUBMITTAL REQUIREMENTS Mark each box to designate that the information has been provided. Please submit this checklist as part of your submittal documents A. X❑ SITE PLAN — REQUIRED WITH ALL SUBMITTALS (May be included as part of the Architectural Drawing cover Sheet) 1. Drawing shall be prepared at scale not to exceed 1"=20 feet. 2. Show building outline and all exterior improvements. 3. Provide property legal description and show property lines. 4. Provide dimensions from the property lines to a minimum of two building corners(or two identifiable locations for irregular plan shapes). 5. Show building setbacks,easements and street access locations. 6. Indicate North direction. 7. Indicate finish floor elevation for the first level. 8. Provide topographical map of the existing grades and the proposed finished grades with maximum five feet elevation contour lines. 9. Show the location of all existing underground utilities, including water,sewer,gas and electrical. 10. Flood hazard areas,floodways, and design flood elevations as applicable. B. ® ARCHITECTURAL DRAWINGS 1. ® Cover Sheet a) Building Information 1. Specify model code information. 2. Construction Type. 3. Number of stories and total height in feet. 4. Building square footage(per floor and total) 5. IBC Occupancy Type (show all types by floor and total). 6. Mixed-use ratio(if applicable) 7. Occupant load calculation(show by occupancy type and total) 8. List work to be performed under this permit b) Design Team Information 1. Design Professional in Responsible Charge 2. Architects 3. Structural Engineers 4. Owner 5. Developer 6. Any other Design Team Members 2. ® Floor Plan a) Plan view 1/8" minimum scale. Details a minimum'/-inch scale. b) Plans must show the entire tenant space. c) Specify the use of each room/area. d) Provide an occupant load calculation on the floor plan.(on every floor, in all rooms and spaces) e) Show ALL exits on the plans; include new, existing or eliminated. f) Show Barrier-Free information on the drawings. g) Show the location of all permanent rooms,walls and shafts. h) Note the uses in the adjacent tenant spaces, if applicable. i) Provide a door and door hardware schedule. j) Show the location of all new walls, doors,windows, etc. REV 2015 Page 3 of 7 G1�Y Off, COMMERCIAL REMODEL • • PERMIT APPLICATION Department of Community& Economic Development City of Arlington • 18204 59th Ave NE •Arlington, WA 98223 • Phone (360)403-3551 k) Provide details and assembly numbers for any fire resistive assemblies. 1) Indicate on the plans all rated walls, doors,windows and penetrations. m) Provide a legend that distinguishes existing walls,walls to be removed and new walls. 3. ❑ N/A Reflected Ceiling Plan a) Plan view 1/8"minimum scale. Details a minimum'/-inch scale. b) Provide ceiling construction details. c) Provide suspended ceiling details complying with IBC 803.9.1.1.Show seismic bracing details. d) Show the location of all emergency lighting and exit signage. e) Detail the seismic bracing of the fixtures. f) Include a lighting fixture schedule. 4. ® Framing Plan a) Specify the size,spacing, span and wood species or metal gage for all stud walls. b) Indicate all wall, beam and floor connections. c) Detail the seismic bracing for all walls. d) Include a stair section showing rise, run, landings, headroom, handrail and guardrail dimensions. 5. ❑N/A Storage Racks(if applicable) a) Structural calculations are required for seismic bracing of storage racks eight feet or greater in height. b) Eight feet or less,show a positive connection to floor or walls. NOTE: High pile storage shall meet the requirements of current International Building and Fire Codes. C. ❑ N/A SPECIAL INSPECTION 1. Where special inspection is required by IBC 1704,the registered design professional in responsible charge shall prepare a special inspection program that will be submitted to the City of Arlington and approved prior to issuance of the building permit to comply with IBC 106.1. D. ❑ N/A WASHINGTON STATE ENERGY CODE 1. One(1)completed Washington State Non-Residential Energy Code Envelope Summary forms. E. OCCUPANT'S STATEMENT OF INTENDED USE 1. The Occupant's Statement of Intended Use form shall be completely filled out and may require the submittal of a Hazardous Materials inventory Statement(HMIS). Contact the Arlington REV 2015 Page 4 of 7 CITY OF ARLINGTON 238 N. OLYMPIC AVE - ARLINGTON, WA. 98223 — PHONE; (360) 403-3551 BUILDING PERMIT Address:19406 68th Dr NE Permit#:2249 Parcel#:31051400300200 Valuation:45000.00 OWNER APPLICANT CONTRACTOR Name:WESTERN FOREST PRODUCTS US LLC Name:Kara Eberle Name:JR ABBOTT CONSTRUCTION Address:800-1055 W GEORGIA STREET Address:200 West Mercer St.Ste 503 Address:3408 1 ST AVENUE S City,State Zip:VANCOUVER,BC V6E3P3 City,State Zip:Seattle,WA 98119 City,State Zip:SEATTLE,WA 98124 Phone: Phone:206-395-7603 Phone:206-467-8500 MECHANICAL CONTRACTOR PLUMBING CONTRACTOR Name: Name: Address: Address: City,State,Zip: City,State,Zip: Phone: Phone: LIC#: EXP: LIC#: EXP: JOB DESCRIPTION PERMIT TYPE: Commercial Addition CODE YEAR: 2015 STORIES: CONST.TYPE: II B DWELLING UNITS: OCC GROUP: BUILDINGS: OCC LOAD: PERMIT APPROVAL I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY; NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18.27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERT4ityotonl#3101. UPANCY HAS BEEN GRANTED. IBC IOARC110. ALESles tax relating onstntction and construction materials in the City of Arlington must be reported on your sales tax return form and cod t Print Name Date Released By D•tc CONDITIONS Adhere to approved plans. Please call for final inspection. THIS PERMIT AUTHORIZS ONLY THE WORK NOTED.THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN(CURBS,SIDEWALKS,DRIVEWAYS,MARQUEES,ETC.)WILL REQUIRE SEPARATE PERMISSION. PERMIT FEES Date Description Fee Amount 12/6/2018 Building Permit Fee $856.68 12/6/2018 Building Plan Review Fee ..84 84$556 12/6/2018 Processing/Technology Fee 556 12/6/2018 State Surcharge-Commercial $2500 $25.00 Total Due: $1,463.52 Total Payment: $0.00 Balance Due: $1,463.52 CALL FOR INSPECTIONS BUILDING(360)403-3417 When calling for an inspection please leave the following information: Permit Number,Type of Inspection being requested,and whether you prefer morning or afternoon RAL �NWENGINEERS STRUCT Engineers Northwest inc.,P.S. WESTERN FOREST PRODUCTS MILL 19406 68T" Drive Northeast Arlington, WA 98233 STRUCTURAL CALCULATIONS FOR FIRE BARRIER SSrG` 2015 International Building Code October 29, 2018 Received ENW# 18039000-6 OCT 3 0 zags P 9725 Third Avenue NE,Suite 207 Seattle,WA 98115 206.525.7560.fax 206.522.6698 www.engineersnw.com 10/29/2018 Design Maps Summary Report 1 M(M Desig:: Maps Summary Report User-Specified input Report Title Arlington, WA Mon October-29, 20 18 1 7:59;54 l I rfi Building Code Reference Document 2012/2015 International Building Code (!vhieh utilizas UGGS hazard data available iu 2003) Site Coordinates 48,171991N, 122.137451W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III Stanwood, �� . � ,r• FBEY HUL r F QK T, _ AW-1AL ��5TILLAAAUISN � SLISAW r�' BAY Arlington . r !"fN �Itrr -�•r�:;�-1 l ' Varm Beach II 1 lql✓ H T JUL r WSINVAPON i granite FAs SGS-Provided Output Ss = 1.064 g SM5 = 1.143 g SDI = 0.762 g SI = 0.414 g SMI = 0.656 9 Sol = 0.438 g For information on how the SS and 51 values above have been calculated from probabilistic (risk-targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the"2009 NEHRP"building code reference document. NIC'FSa Response Spectrum Design Response Sptxl rum sas PA I�, t,M• {.ay 4Pi fr4:i 1,sa a "A2 t'rli• --F-� !-f -,O pi: 01I,i �Ifol 01AMI 1)" I. 14:; tie' IA. e:.�. i.-Nf +.[, �.. I•=1 l.J, 1A I_U, G11 „_,L. 'Inugh this infortvlation is a product of the U.S. Geological Survey, we provide no warranty, expi ssed or impl!ed; as to the ,hracy of the data contained the'ein. This too! is not a sub7t tote for technical;ub)ect-rnnWir knowledje. https://prod0l-earthquake.cr.usgs.gov/designmaps/us/summary.php?template=minimal&latitude=48.17198911179904&longitude=-122.137451447196... 1/1 10/8/2018 ATC Hazards by Location LD, This is a beta release of the new ATC Hazards by Location wrebsite. Please contact us with feedback. OTC Hazards by Location .-arch Information Address: 19406 681h Dr NE,Arlington,WA 98223,USA Coordinates: 48.1726531.-122.13859930000001 Timestamp: 2018-10-09T00:20:36.166Z Hazard Type: Wind Map Results Nanaimoo Rirhmondo Surrey g' - ,e ):uSf2•tl _ d r a G r, Mi- 8aI•e�•5nuquatmie Ctifvlllr ,,,..:1 'IaVIliai f Il'EI. �,,,�,j�c tJ+IliOntil Futrii V}6tot �151 ft1 �_ , . r •!�. r,k�Q�@i. spnti.)nn �t a ,r ��- u• 71, j¢Taeon -WASHINGT0N [7 ✓, ir.: l�r.- 4 t - LL7&"LA" Text Results ASCE=7_16 MRI 10-Year _. ... 68 mph MRI 25-Year 74 mph MRI 50-Year _... . _..... 79 mph MRI 100-Year 84 mph Risk Category I 93 mph Risk Category II . .-. ._.. - 98 mph Risk Category III 105 mph Risk Category IV 109 mph ASCE 7-10 MRI 10-Year 72 mph MRI 25-Year 79 mph MRI 50-Year 85 mph MRI,100-Year 91 mph Risk Category 1 100 mph Risk Category II 110 rn https://hazards.atcouncil.arg/#/wind?address=19406%2068th%2ODr%20NE%2C°/a2OArlington%2C%20WA%2098223%2C"/`20USA&Iat=48.1726531... 1/2 ENWENGINEERsNORTHWEST, INC., P.S. STRUCTURAL ENGINEERS 9725'1'[-]IRD AVE T\C,Surrr 207,Sr_nTrLr,W.A 98115 (206)525--7560 FAX(206)522--6698 PROj cT# atx9` NOJEC'r A'KT11$Ar-nV AAlt-L,S DATE SUBJEC-C - - f-c,&IAC. 60-nf,4 * " R� 1`vARZLI�R SHEEr Or _ By IpC-5c 7-A*j : T'o ot,5rGvj 1=sft OA19 RtVX Lo/ `T""1' 6kt,f FrA,,,". CCT�- : 2-4:15 z I3 4, 1.4kp7�s/L� : ROUT ' L L-r ENGINEERS-NORTHWEST.INC.P.S. SHEET OF 9725 THIRD AVE N E (SI IITE 207.) SEA71'LE,WA.98115 `''•Property of Engineers Northwest.Inc.,P.S.- Use by others unlawful ASCE 7-10 Wind Loads per ASCE 7-10-Chapter 30-Components&Cladding-h<_60'-0" Input Cells= Project Number: Project Name: Mill Arlington T— Location: --� Design By: Program Limitations: 1. Building must be a low-rise building or 2. Building mean roof height does not exceed 60 feet. 3. Building is enclosed or partially enclosed. BUILDING AND SITE INFORMATION INPUT Building width,B= 98 It Building length,L= 150 It Building eave height,he= _ 22 ft Building ridge height,hr= 25 ft Height of parapet,hp= 24.5 It Roof slope,s= 1,0�U in.lft =4.76 degrees Is roof a gable or hip= Gable Risk Category= II Wind velocity,V= 110 mi/hr = 85 mi/hr(ASD) Exposure= Topographic factor,K,I= q Wind directionality factor,Kd= 185 Bldg internal pressure condition= Part _Enclosed Wall Effective Wind Area,EWA= 165 h' Roof Effective Wind Area,EWA= 7 II` OUTPUT Mean roof height,h= 22 ft a= 8.8 It Internal Pressure Coeffs,GCpi= 0.55 -0.55 Pressure exposure coeff,KI,= 0.64 Velocity pressure,q = 16.85 psf COMPONENTS AND CLADDING(C&C) p=gn((GCp)-(GCPi)l(lb/ft2) Wind Pressures for Walls with h<_60' "Note Design wind pressures shall not be less than a net pressure of 16psf(ult) acting in either direction normal to the surface. Wind Pressures Acting Toward Surface Bldg Surface 4&5= 21.2 psf(LRFD)=12.7 psf(ASD) Wind Pressures Acting Away From Surface Bldg Surface 4= -22.7 psf(LRFD)=-13 6 psf(ASD) Bldg Surface 5= -24 psf(LRFD)=-14.4 psf(ASD) I s i+ .may o 5 5 Copy of ASCE7-10 Wind Leads Low Ri se.xIsx C&C EN GIN EERS-NORTHWE ST,INC.P.S SHEET OF 9725 THIRD AVE N E.(SUITE 207) 111 SEATTLE.WA 98115 Wind Pressures for Roofs(gable roofs.&bin roofs)with h <_60' `Note: Design wind pressures shall not be less than a net pressure of 16psf(ult) acting in either direction normal to the surface. Wind Pressures Acting Toward Surface Roof Surface 1,2&3= 12.6 psf(LRFD)=7.6 psf(ASD) Wind Pressures Actina Away From Surface Roof Surface 1 = -24A psf(LRFD)=-14.6 psf(ASD) Roof Surface 2= -27.8 psf(LRFD)=-16.7 psf(ASD) Roof Surface 3= -27.8 psf(LRFD)=-16.7 psf(ASD) Wind Pressures Actlnq Away From Surface(overhang) Roof Surface 1 = -23.3 psf(LRFD)=-14 psf(ASD) Roof Surface 2= -23.3 psf(LRFD)=-14 psf(ASD) Roof Surface 3=�I -13.5 psf(LRFD)=-8.1 psf(ASD) 02 I I 02 1 1 \ 1 I I I H -- a 1 I t i 1 1 1 .5. Ifa pmapet equal to or highur Iwo 3 h ff>.Pm)is provided around Ihi perimeter of the ioal�wdh(i t:7". the negative values of CiC",ill Zone 3 shall Lc equal to th05u 1101 70uc 2 autl positive values o(fiC in ?ones 2 and 3 shall Iw set equal to)hose f01'n;vll"Zones 41uid 5 respeclively in Figure.30.4-1. Wind Pressures for Parapets feeble roofs.&hip roofs ,with h<60' 'Note: Design wind pressures shall not be less than a net pressure of 16psf(ult) acting io either direction normal to the surface- pp=gv[(GCo)-(GCpa)](IblftZ) Velocity pressure,qp= 17.38 psf Parapet Load Casa A Wind load @ corner,pp= 31.4 psf(LRFD)=18.8 psf(ASD) Wind load not @ corner,pp= 31.4 psf(LRFD)=18.8 psf(ASD) Parapet Load Case t3 [� ✓ ��rb l'- Wind load @ corner,pi,= 27.5 psf(LRFD)= 16.5 psf(ASD) Wind load not @ corner,pp= 26.1 psf(LRFD)=15.7 psf(ASD) Windward jv,aper Leeward patupel Load Case A Loud Case Il Top nf'parapot 4,30 c• �rq Fey i:l.i 5331'i•�v .p.r.1 Yr■ "n t. •'. liz lie Nal __—y --4•neau.e`fail: +u3llntl'.vQ an4aal'c Prn-:u u __ IhYALN' :�w7Sl --ter —� ht, Copy of ASCE7-10 Wind Loads Low Rise.xlsx C&C ENWENGINEERs NORTHWEST, INC., P.S. STRUCTURAL ENGINEERS 9725 THIRD AVE NE,SUITE 207,SFAI-I Lb,WA 98115 (206)525-7560 FAX(206)522-6698 PROJECT# PROJEC i' DATE SUfiJ1.C,T SHEET OF BY r SfcZSIMt=t Fe tA-) fUM l r CA b kro a 20 C I Z i C A< Ck K�12 �61) 162 5�- A� 7v d31 � C ST•�, at Tl�cu p, d Project Name: New Workspace Page 1 of 1 Model: Beare/Stud—1 Date:10/15/2018 Code: 2012 NASPEC[AISI S100-2012) Simpson Strong-Tie®CFS DesignerT"2.5.3.0 f Section: (2)600S162-54(50 ksi)Back-To-Back C Stud Maxo= 5054.2 Ft-Lb Va= 5645.8 lb 1=5.72 in^4 Loads have not been modified for strength checks Loads have not been modified for deflection calculations 2.50 20.00 N Bridging Connectors-Design Method=AISI S100 Simpson Strong-Tie Span/Cantilever Bridging Connector Stress Ratio Span N/A Top Cantilever NIA rN Shear and Web Crippling Checks Bending and Shear(Unstiffened): 3.6% Stressed @R2 25.00 15.00 Bending and Shear(Stiffened): NA Web Stiffeners Required?: No r I , Simpson Strong-Tie Connectors Connector Anchor Support Rx(Ib) Ry(lb) Simpson Strong-Tie Connector Interaction Interaction R1 185 0 FCB43.5 Min(4#12-14)&(4)#12 SST X to A36 Steel 18.97% 11.64% R2 240 0 SCB45.5(2)& (2)#12 SST X to A36 Steel 31.58% 30.19% 'Rt:,t i cnce caiaiuy iur connecior anu anuhur requirement notes as weii as screw piacemenis requirement Flexural and Deflection Check Mmax Mmax/ Mpos Bracing Ma(Brc) Mpos/ Deflection Span Ft-Lb Maxo Ft-Lb (in) Ft-Lb Ma(Brc) (in) Ratio Span 1140.8 0.226 1140.8 Full 5054.2 0.226 0.756 U397 Top Cantilever 62.5 0.012 39.9 None 4625.7 0.009 0.236 L/255 Distortional Buckling Check Span K-phi Lm Brac Ma-d Mmaxi lb-in/in in Ft-Lb Ma-d Span 0.00 300.0 4316.7 0.264 Top Cantilever 0.00 30.0 4316.7 0.014 SIMPSON STRONG-TIE COMPANY INC. www.strongfe.com Project Name: New WorkSpace Page 1 of 1 Model: Beam/Stud—1 Date:10/15/2018 Code: 2012 NASPEC[AISI S100-2012] Simpson Strong-Tie®)CFS Designer7°2.5.3.0 Section: 60OS162-54(50 ksi)Single C Stud Maxo— 2527.1 Ft-Lb Va= 2822.9 lb I= 2.86 in^4 Loads have not been modified for strength checks N Loads have not been modified for deflection calculations Bridging Connectors-Design Method=AISI S100 Simpson Strong-Tie Span/Cantilever Bridging Connector Stress Ratio Span N/A - Shear and Web Crippling Checks Bending and Shear(Unstiffened): 5.3% Stressed @R1 20.00 1S.00 Bending and Shear(Stiffened): NA Web Stiffeners Required?: No Simpson Strong-Tie Connectors Connector Anchor Support Rx(lb) Ry(lb) Simpson Strong-Tie Connector Interaction Interaction R1 150 0 FC1343.5 Min(4412-14)& (4)#12 SST X to A36 Steel 15.38% 9.43% R2 150 0 SCB45.5(2)&(2)#12 SST X to A36 Steel 19.74% 18.87% Reference catalog for connector and anchor requirement notes as well as screw placements requirement Flexural and Deflection Check Mmax Mmax/ Mpos Bracing Ma(Brc) Mposl Deflection Span Ft-Lb Maxo Ft-Lb (in) Ft-Lb Ma(Brc) (in) Ratio Span 750.0 0.297 750.0 Full 2527.1 0.297 0.640 L/375 Distortional Bucklinq Check Span K-phi Lm Brac Ma-d Mmax/ lb-in/in in Ft-Lb Ma-d Span 0.00 240.0 2158.3 0.347 SIMPSON STRONG-TIE COMPANY INC. www.strongtie.com I ENWENGINEERs NORTHWEST, INC., P.S. — STRUCTURAL ENGINEERS 9725 Tl=IRD Ave NE,Sui rE 207,SLATTLr,WA 98115 (206)525--•7560 FAX(206)522-6698 PROJECT# PROJECT � DATE- SUBJECT _.. SHEET-OF- By A*W Rue7� � Lgyu GF{� Tille Block Line 1 Project Title: <J You can change this area Engineer: 4 using the"Settings"menu item Project ID: and then using the"Printing& Project Descr: Title Block"selection. Title Block Line 6 Printed 29 ocT 2016. 2A7I'M Steel Beam - - Fde-CW9 sVchz%Desktop11I v6 61 Software copynght ENERCALC,INC 1983 2018,0uM f018 9 30 Description: --None- CODE REFERENCES Calculations per AISC 360-10, IBC 2015, CBC 2016,ASCE 7-10 Load Combination Set:ASCE 7-16 Material Properties _ Analysis Method: Allowable Strength Design Fy:Steel Yield: 36.0 ksi Beam Bracing: Completely Unbraced E:Modulus: 29,000.0 ksi Bending Axis: Major Axis Bending Span=30.0 ft Applied Loads Service loads entered Load Factors will be applied for calculations Beam self weight NOT internally calculated and added Uniform Load: D=0.0050, Lr=0.0250 k/ft, Tributary Width-1.0 ft DESIGN SUMMARY _ _ _ ___ •== , • Maximum Bending Stress Ratio = 0.730: 1 Nlax_imum Shear Stress-Ratio= 0.014 : 1 1 Section used for this span C8x13.75 Section used for this span C8x13.75 Ma:Applied 3.375 k-ft Va:Applied 0.450 k Mn/Omega:Allowable 4.623 k-ft Vn/Omega:Allowable 31.352 k Load Combination +D+Lr+H Load Combination +D+Lr+H Location of maximum on span 15.000ft Location of maximum on span 0.000 ft Span#where maximum occurs Span#1 Span#where maximum occurs Span#1 Maximum Deflection Max Downward Transient Deflection 0.437 in Ratio= 823>=360 Max Upward Transient Deflection 0.000 in Ratio= 0<360 Max Downward Total Deflection 0,525 in Ratio= 686>=180 Max Upward Total Deflection 0.000 In Ratio= 0<180 Maximum Forces $ Stresses for Load Combinations Load Combination tvlax Stress Ratios_ Summary of Moment Values _ _ Summary of Shear Values Segment Length Span# M V Mmax+ Mmax- Ma Max Mnx Mnx/Ornega Cb Rm Va Max Vnx VnxlOmega Dsgn.L= 30.00 If 1 0.122 0.002 0.56 0.56 7.72 4.62 1.14 1.00 0.08 52.36 31.35 +D+L+H Dsgn.L= 30.00 it 1 0.122 0.002 0.56 0.56 7.72 4.62 1.14 1.00 0.08 52.36 31.35 +D+Lr+H Dsg n.L= 30.00 ft 1 0,730 0.014 3.38 3.38 7.72 4.62 1.14 1.00 0.45 52.36 31.35 +D+S+H Dsgn.L= 30.00 It 1 0.122 0.002 0.56 0.56 7.72 4.62 1.14 1.00 0.08 52.36 31.35 +D+0.750Lr+0.750L+H Dsgn.L= 30.00 ft 1 0,578 0.011 2.67 2.67 7,72 4.62 114 1.00 0,36 52.36 31.35 +D+0.750L+0.750S+H Dsgn.L= 30.00 It 1 0.122 0.002 0.56 0.56 7.72 4.62 1.14 1.00 0.08 52.36 31.35 +D+0.60W+H Dsgn.L= 30.00 ft 1 0.122 0 002 0.56 0.56 7.72 4.62 1.14 1.00 0.08 52.36 31.35 +0+0.750Lr+0.450W+H Dsgn.L= 30.00 ft 1 0.578 0,011 2.67 2.67 7.72 4.62 1.14 1.00 0.36 52.36 31.35 •D+0.750S+0A50W+H Dsgn.L= 30.00 ft 1 0.122 0.002 0.56 0.56 7.72 4.62 1.14 1.00 0.08 52.36 31.35 +0.60D+0.60W+0,601-1 Dsg n.L= 30.00 ft 1 0.073 0.001 0.34 0.34 7.72 4.62 1.14 1.00 0.05 52.36 31.35 +D+0.70E-460H Dsgn.L= 30.00 ft 1 0.122 0 002 0.56 0.56 7.72 4.62 1.14 1.00 0.08 52.36 31.35 +0+0.750L40.750 S+0.5250 E+H Dsgn.L= 30.00 ft 1 0122 0.002 0.56 0.56 7.72 4.62 114 100 0.08 52.36 31.35 Title Block Line 1 Project Title: You can change this area Engineer: using the"Settings"menu item Project ID: and then using the"Printing& Project Descr: Title Block"selection. Title Block Line 6 _Panted:29 OCT 2016, 247PM Steel Beam He=CWs=VvchzOwktoplll ec6 Software ajDyrOtENERCA C INC 19B3.201B-Build I 18930 Description; -None- Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span# M V Mmax+ Mmax- Ma Max Mnx Mnx/Omega Cb Rm Va Max Vnx Vnx/Omega Dsgn.L= 30.00 ft 1 0.073 0.001 0.34 0.34 7.72 4.62 1.14 1.00 0.05 52.36 31.35 Overall Maximum Deflections Load Combination Span Max.""Den Location in Span Load Combination Max.'+"Dell Location in Span +p+Lr+H 1 0-5246 15 086 D.00OD 0.000 Vertical Reactions _ _ Support notation:Far left is#1 Values in KIPS Load Combination _ Support 1 Support 2 OverallMAXimum 0.450 0.450 -' Overall MINimum O.D45 0.045 +D+H 0.075 0.075 +D+L+H 0.075 0.075 +D+Lr+H 0.450 0.450 +D+S+H 0.075 0.075 +D+0.75OLr+0.750L+H 0.356 0,356 +D+0.750L+0.750S+H 0.075 0.075 +D+0.60W+H 0.075 0.075 +D+0.750Lr+0.450W+H 0.356 0.356 +D+0.750S+0.450W+H 0.075 0.075 +0.60D+0.60W4601-1 0.045 0.045 +D+0.70E+0.60H 0.075 0.075 +D+0.750L+0.750S+0.5250E+H 0-075 0.075 +0.60D+0 70E-FH 0.045 0.045 D Only 0.075 0.075 Lr Only 0.375 0.375 L Only S Only W Only E Only H Only Permit#: 2249 Permit Date: 10/31/18 Permit Type: COMMERCIAL ADDITION Project Name: WFP Arlington Mill Renovation- Fire Separation Applicant Name: Kara Eberle Applicant Address: 200 West Mercer St. Ste 503 Applicant, City, State, Zip: Seattle,WA 98119 Contact: Kara Eberle Phone: 206-395-7603 Email: karae@ctagroup.com Scope of Work: Fire Separation Valuation: 45000.00 Square Feet: 169058 Number of Stories: 1 Construction Type: Occupancy Group: ID Code: Permit Issued: 12/11/2018 Permit Expires: Form Permit Type: Status: LASERFICHE Assigned To: Raelynn Jones Property Parcel# Address Legal Description Owner Name Owner Phone Zoning WESTERN FOREST 31051400300200 19406 68TH DRIVE NE PRODUCTS US Planing Sawmills& ning Mills LLC Pla Contractors Contractor Primary Contact Phone Address Contractor Type License License# JR ABBOTT J.R.ABBOTT 206-467-8500 3408 1ST CONSTRUCTION Labor&JRABBCI022JZ CONSTRUCTION AVENUE S CONTRACTOR Industries Inspections Date Inspection Type Description Scheduled Date Completed Date Inspector Status 01/02/2019 C20.BUILDING Firewall approved 12/18/2018 12/18/2018 BUILDING Approved FINAL Plan Reviews Date Review Type Description Assigned To Review Status 10/31/2018 COMMERCIAL BUILDING ADDITION Fees Fee Description Notes Amount Building Permit Table 4-1 $856.68 Building Plan Review Table 4-2 $556.84 Processing/Technology $25.00 State Surcharge-Commercial Commercial Only $25.00 Total $1,463.52 Attached Letters Date Letter Description 12/06/2018 Building Permit Payments Date Paid By Description Payment Type Accepted By Amount 12/11/2018 David Garcia 72998621 cc Raelynn Jones $1,463.52 Outstanding Balance $0.00 Uploaded Files Date File Name 01/02/2019 4366795-2249 12-18-2018Inspection Card.pdf 12/11/2018 4316924-2249 Signed permit.pdf 10/31/2018 4140745-2249 Application.pdf 10/31/2018 4140746-2249 Structural Calcs.pdf V W E ►.LL)z NWW NOIJLVUVd3S 3NIJ - NOUVAON3N 11IW NOIDNIINV dMNopwUm<dE£Z96 dM `NOlONMJV u�� 3co CID 3N 3nlba H189 90b6L - o >m V �m❑Z �❑ow O 1 0 o ! U ol LL m a I cx_ �O�FF��W W�ZO IIII 1 ''1 OF W CL 0- Np I ; i A... i \ \ ` \ `\ �." .n O?A �TO Z m 1'III i 11'1 \ ZI 11 I III 1 '' 1 ' ` ❑ :.O W l I - E: 1 - ____________n 1_ J 11 m m m Z I pccEss 68TH DRIVE NE I Z 3 pO1M �� (A DEDICATED PUBLIC I .al W 1 ' 11 1 a RIGHT OF WAV 1 1 ----- _ --- ___ 1}11 a Z LLJ IT nn r1��t1' 1l r LL I \ II I I I �LU 1; i0 .JW o U -- LLJ o O O 1 W 1 I O I W I Sal I; III 2 Y K 1 I O 1 I1 V II 1 i '11 I 1 I I I r I I 1 1 1 1 --- ------ 1 I I / �- ------ ---- T 1 1 1 I It Iq I \`N A I �__�_� (A DEDICATE WAy�IC > z U 0 EdOW S O K 0. O O O wo=r LL-� z m¢a Zrc r3 mago�`Z. 0ww¢°cai w wmor�� F �ooa �O�a1a-FF� OOWWOa z ¢¢ww?Ww Wo�W� m mmmm mmym �1-�w- J »» > 3333. O F ti F w U ❑ �uLLiydCN�l=¢ 0❑W-mod O ¢mw(7?u� O3 - ymwwmm "F—P-� > »»»> 33333 z a 0 O 1 z 2 z p _o =O O z r w O g ¢ H rn r ❑ a - go LL O ti❑F ~Ox w z� O y a z a z ❑ m W U J ¢ 00 o OLL Z Z 5o zY �co J z� a < z m m m �aN� �� w zz`° w�� m >>i I- ❑ OOQ am❑ W 7 O. a Jw 0❑--O J W z Way F F W j U UZ Z z,-W'L >jF m ❑ >o U JQ aa aw.:�.¢ >z r- a o za a Jwz'' o F' Cz (7N u3 m W �W- 0 zF 'L 0� ULLJz OU'ug z..U❑ O W Q U W LL�i O �Cw7 �jZ¢Z» mw3 O' O W F¢ ¢O O >.]g❑U U�¢ Y pU 'n W W m� mp1�- w OpZ W 3 W W x 0 0>u>ym w❑°2ti "''3z �� w ,.zidg a» o Om y w�aU ❑ aa�z r QKQKz��nww Jmw = O VO''O� JJ ZJO.d G Occ OWJW O¢a>O 'i0W J2GZ �h3 tt ZO < .� zLL zy W220 Is -0 WOO JO Qau¢Y> OWO-W >mr- w> J yH ❑ Ow00 »Z»2m OWO.g USZ ZZWK Q O�»Z Fw❑ IIww 'rt I-.- OU'(�UU'C7 22222 ZZZZ O 'aa �Z m2 2=J vI fi (7 QaQa mmy Jg'� �gg�� -J2��g� ZZZ2 0000000 aaaanaa aaaa d OwwO¢- ¢¢mm5 NNr/O1 > U QQQU_3i a a m C�0c7/7UO 52222 owz_ > J3 :y G �ZS2 m mLL�y 7 ❑ Uj �'Sj � ���gs z_zzz oOoOoO❑ aa-'g z�+Nr-� �. °wwo3 c2icii > i-3 U aO❑xaw aaaa da aaaa O KKmmm yyy U Q Z f- W 0 O Z w W W ZLu W 1 m W Imo m Z W U a o w �z 9 z z z o a Q d w W V) w o �� i z e a < a w 0 zXaU w by m z Z U Z z Jx ❑ 0 2w wZ o0 ti U U W rr o ❑ W woJ 3 w z F~ w _ �� 2 zo m� z w ❑ w a N mm� ow mW zx o 0 0 3 x �0 wao �m �~ Qm m �o ww H Fr >w wZm Q I.G w0X m I—LL'H K W 2 Z O Oi" J W 1_. Qm N OZ ~ m 1'2 z Ka O W Z� w 22 R'R'❑❑w U'W'z r- am w 4 w ❑ _J a za- w mm Wzz- mwy m war, w m LG 3wy 2 H Fo J ymN w 0a❑�c~i�� 3.n zz F❑ oow00-Ow a V) > VJ�; 2 U �"'" ❑ oaktF tea❑ azp w. �0 w� _ S Q Qa. W�3 ~mom= Ww a �zz j U�wyp z �zu� i _Q wow��Uwz�zppNorz� wO z�LL�� umzo Uwzw�LLo U ~ x Zzzo OON Mg'If LLB- !- yU y� _ 1- W 2 Z gm O❑ a LL ❑ U d'�m K '...O W W Q Him ,y, m ozm >V W❑Kq>�W�22❑�x�0 K2'wp Y2000 - KZd:CCgC2 W Z CL W a ��__ Z_ _ a0 ¢❑i-I--I❑❑-J V LL m °i ��w a > J wa O VOwJO I,aj2=2zOz jO¢ tixUaa�'- ¢ZwW2222o-'OOOno W zxOI� W 0¢w�� wUaNY (�z.Qa zw¢oQ m>3 ❑ m�V UI�❑m��<zzz"3 a° JOzUF � >�"�z� U UF�Z XX ww Z LL'�I-N V ZO >N =�K3N m �3 1� W O W W�J W..aG G Q.^,O W J000000 O W W yUw=❑x W O W W my N(/JO W W W 2F- W w'- ZoLL¢z�� Owu m� �03 o>go J ¢zoF aaaa¢aaa¢¢aaaaaaa mmmmmmlmmm c x ¢ V W W n~ Ua F U mF U:J UUU UUU UUU ❑❑❑ W Q W Qw IL O�II IL LL Ez Il OLL LLLLLL°LL tiyzNF OC a Uz�J� w2JNU ti wm Q-'-0v, M WW m cri �wm�?z ��=mz�z fY�3Kry1¢- �zt-�w� Z�m�+.a I- 0] x m ma Mze /y� ❑¢x o oc� 0 3 aoVi UO O OLL u�<0 Q�o W.0 ,~/�znwmoo O m c"z W z W m>UUU�PLL J��z2z a¢in� UHmNU v,W mmNU U Sm rAnUO C U^2'm°° Q¢¢¢qq q¢¢¢aq¢a aaaa ❑W wg 0� O OWD zz �F QQw a W 2 ¢m U m m m m m m m m~ U J U 3 0 0 0 U OU O D U O❑❑ W W J O U 3 aC Q❑W W LL LL LL 0 0 0 0 W W W w W LLLLI,I ILLLLLLLLL LL E. J m LL 3 Z w z O ¢ > ❑ a a W 0 ZO m z Z _ 01 (n 5 1— w U J R 2 Q n U ❑ Z z _ O 2 a ° 2 y C ly Z y O O f-J � S C w U U ❑ F _z 1 K ¢ w y ❑ m w ❑ ¢m s Z w ❑m J O J O IL y (� ow oo U o o z �� ��//�� LLO O W wU U OO 2 ¢ a m zr' 0 sit v/ 1� ~ UU �❑wa UUU mwai w 0 �w Q g�� zc2 Qa �❑❑ LL rnm U�"�' c' z Uwe OU¢ aLL C as ¢ aFa ¢ mwLLLL c� < c,z-❑ m m x I- W 3 0 Now-,zzo �' <GW�9z zu�vaN�Nu�O >, o Z ❑U U O U Q U Z O U W F-K F W o�N❑N m O = - L 5 O 0. 0. �ww�azm w �0 O 0 ` Q U U�V U W mC�J 5�liy w� C Z U 1� U) a W 002<L., CC, >¢¢QQ�Q" O O J J F— in .J mUww C—)— zy-~ai zvi, w F- � J 7 W 7WW❑K�-� w2zzz-z Q W ��L// '/^� co m1Q.7HUt�i a<g �OOOO SOU ran O LL VJ /1I " a Wp zz zzzzzz`d ¢Z(~9 U~' ~U'�C~7� woa O U m W Q �/ O o00000000� �=222n2w 2a° ,Q O L Q Vp FFF ti FF'-m ¢mmu�m,_m-� w J N W z U aaaa aao- aaaa aw °you WU LLm C a �8 zr,,xX r�=w zp333 aim OOOz ❑z I— y Z a (n 1, Oo J -owWWWWwwm y0 w_ li of 0 j0 a 2r_��r-���¢� 0`7���nh�� -30��JQ V o3 J�J M �� azzzzzzz3¢ �h��h��� az ar< W z Wo € J W W zcxi Q- �000m "oyy =<aaaaaa Omo�Qzom ��o Uo F r__ a a 0j ZNNN N$R Q3333333 Z�c27w R'IWiw 0m0 Q' W n 3. ;s Y 3r zwz a� NOIIVHVd3S 3111= - NOIIVAON311 IIIW NOIJNIIZIV d�M � o a � 3W NaG CM6 VM`NOiSNM:lV _ w g C 3N 3nRia H189 90ti66 n / m o N z x 0 o CL LL I C7 z m z C7 W U y z Z U g Fy� py a O m mwo �Oy/z 2 O fWf��� y( 3ZC = x Wm �O �p Q U m Z x y 0 m W Z 2 a° ~ n m J �O �q�7zxu�3 wz g0: oqF FwZaw JFHwp ° w yU O � g o 050y�=LL Nj �o syjU ww WOw �pa¢LL �mi w 3 vwi w LLK �a Q J aU U O°p 6LL C2jy� �Ott� O y z 0 z O v~i lgWgy°Ww�pza� °pUzw �F¢Oy O m Z,Q ° 3 �(9 W O 0 O m W U Z m a z- O g U U m U O p Z a z J z y Q G r W O K a W C C W 9 z p Z z N F UUU a>¢z W °3 yi =Oa LLGU-N xQQ y W OZz Z H° O� O O 2 w m° Uy �a jm Oa dLLLd111]]]? O-> O-O D: UW y U'� m -zm y� 00 02G Uzo :i 1 UF�J� 2aFaG� d G Nymj F"a I-0 1- O 0 m m m m gFy[�aF Z QQ W FHh'O wO� U QKv) I W fLQ WL F Cx z>i Zq z U �z F v' >�'>?2�x " Utz aU HyaO as wiQQyy 0 y� r y 03 00 U0 O O 3F �z o w OF °CNO d OF LL�W z o 5— �NN�y y 2-0 O O 6 w ZZ Z 2 °a OF QZ K V Q O W 2 W O y N O w r U' U H m W Z y y W F LL K z la-W w y W 3 W y W C C 0 y W 2 ~ gy3yy3agq O� Fz3 yF z ON W W° O W LL.W U O Y W° Z Y W Q W x -x K �( QQq FX °. O U0z0w a aa� m OU= W KOW 00z 2~ Uzz 0.z UaQ�d'Q z C 2 � z 0y °W DO C W CLL �IILL� a 5 V w w z FZO�OF Cx y ZO mxZzUy�LLZZ C (yOdF Q J H O' w ` m xQ —� o °zf�x� 4�; oNy w3-� zQoo6 000z� zFFFzwN J m w ° zp 5p zw U o�oQo Jy ZW� zzw °zcyn��z o»=3`� c�wp� a' 0 ° i w zw i7� a3 z Q 21z z �,z FOOT ¢m O "mx 7°a Q W F -i I Q ywa yNa Z x r/O� �y m �QC'mC a w Z N m W H Z Q °V W z W W W z 6°O-y Z Z O J� Z N Z Z w H C 6 z o w W w xozx� w �az o��� wLLzm=� w000ga wyo° }• Q o WUZV c7m LLJ °°°� c�oam3o cODUxya P Q. w LL ¢ J ^a i \ w Y I I l I, I J t, I' illy illl .e/b•�Bb .0-.45 -- -- - ------- j'7------ -------------- ------ --- 01 -------- \ 1 , - oamdln \I � U N _ \\\\\\ LU \\\� \ \\\\ \\1 z X zW� a NOI1VNVd3S 3MIJ - NOIIVAON3N -IIIW NOlJNl'lMV dJM r <� W� - to O y F a W O O wn dYa NWW �o £EZ86dM`NOlJNll21d _ �� >mm w 3N 3/�I2�a H189 90ti66 L m ~_N �Z W o co M V■< 3IL LLJ �ocxr, 0 o 3 w °y sW 0 QV m mz �� a �0 w 3- 1 y Wz W0 4 az ---------�---------------- - --------------- ---- -------------------- ------ - -- - --- --- ----- ----- -- - --------- - -=------I-� _____________ r_ I KN 0 KU I I I 1 Z m zQ I I I I 0. rr 0rrn WO K Nm wmo U hz r�m �2 Wa0 U W U I I zC r 0 I - 7• z Ix.UVx-U m0 N pWp �I �Oorrn>x>x o��Jgwgw Z ww�w� pa,w(Q�C7U0 W Z y ¢Za' Id J U) U o Rxw ow a J W w W Q z zxz Nm > �Uw w a LL a z° ...w Z. 0 r °gg y n =N w r Qw m ¢ W U I Z W x O N mw F W �w O SOU' ¢a m K¢ wm C7y ,w U 0 p 0z p °UN w0 a� mU N o f u0 U yz L m 00 poi 0 ¢ m aZ m� wo o°w ? ¢w Y�O w J - 3� v wci --�'- - --- �g g= m�� F g I -- — I Z W" am 0a� y W C W scy W ZNN W 6 1 I w0 7•pZ �U�U °wmwvi rt— I I w� Z_______________ _________ ____ _______ ___ _____________ __ ______ kyky Opm2 x— zW w w w H VJ Q \- — —————— -- Q ¢ z m jj fm O = O @ r vTwN Ua H r0 OZ w�m o g 0y,� 00N� ow maJ g1 a Imo------ --------- a z a 3°j , N W �❑� ¢ I �¢ w w. goal Z�y w N I I N> > WO 0Tm¢ r XW ----------- --------- - -- ----- ----------------------------------- ---- - w N /-- - _ ------ ------ I w _______________________________________ __________________ _______________________________________�______________ I a 'w x I 20 �� I I I I LLo 0 a N a NwM p I I 1 w km ZoWvrig=g= Z N om¢gwyQw�cwic7 O G N m m LL 0 F- w U) G Oda a zo Z. a NOIlVMVd3S 3NI=l - NOIIVAON311 11IW NOIDNIIUV ddM � o � z "W m ££Z96 dM `NOl`JNIlciV a U)�2 O 3N 3/Ub4 H199 901766 N /' m o Z Y o W o > U■< �WuM, z� dog `4 > 5°z W °w �QQLL m oom U C G U Z a V LLo5 Z �Wzn�' m C m0 x- C ps 1- ',8LL0 LLWt m q Q H r 0 j " m p m m o�=° w w wg 0zwb m Q' m _ vyZ wY,oa r W W W Q LL m m Hz r r W e Z y J c� a° 6° �cri � _ W G O > �a >° Z Q r x r z Q' a W gg W W C N �'1 Ws Q� �a Sa g� Gz z W 22 m Zj W 3 I a Zm> Xm Z, --- I Q J_ W II x x ❑ x II M a II wU Z� �:Iooa rav•nev 'NIW..9•Z �y 2pm wa z z 5a WW� N� w aZ Z�Z a UJ 4 V zW� UQ LLY�o C may �¢w'a m far za r�w a ziooa•rad'nev 'NIW..9`Z —________------ —--------- — — — ————II -- -- — — -_-- 4 II p X X U o X u C—D --- C---- a ------ -- i - zi Y a o i r 1 � X X X Z Z � mo 5N WR 3 ZO QD ZWW II m W U' ma. y m >Z III o� °z �r = O° U ZZr �° o o H I� Y7 m Q� rOZ ... .'•I.I I Q r I Z YQ gW N a 3 a Q Z LL Z .. H U LU ...-. JI 0 =m So = ❑ I U z W HEN 2w ~a w U z woo W Q~ a z3'm O w O z J I, J ° � L H I I- - I x— o W o a W y rc o --------- --_ z z m> wd K a O O N Z o a .................... U m fG o 0 � w a 0 z wzgl z KoH Y < O "-Z Gj U QQ Z r aU F . QzW_ mw z� y LLYpO Om °m w rDw \ 0Saxe m� L) NIW.9•.Z 2Ur? �Z �N o z II X x a 11 x .< II °oz I o a Z\ U o w C7>z O Y 6 wo W ---- -9--�J/ - ---`a— A 2 m Z wai"Oz mW OCwLL�W0m O" Qwar'3 mOwV ww = Q R00 a o� OWo ax w =m �5 W =3mma g LQ_QL'' i �W 0m Y7 I Zm U2 w ax ° O �� _.° w ¢m gam I I NR �m z aw a z I _ PZ < a ----- Q ww za z I I Y Wi zs I w W „z .z Z 10 ° I ° Qi O I o/ °I Q` N w I I W w°W 2O m Q Z I I Q p u Sz Kp W LL U w 4 p� y� yr mp m N ❑ rY m z w ❑ Y y w N Q w a U a' 22 m ZZ J as C K z q W d Z 3j Z Fri a o GD� w Xo 0 � a �a r _m as rn r w 7 8 a C:1Users\pmkashp\appdata\local\tsmp\HCPublish_4352\Arlington Mille Personnel BuildingS1.1-General Notes,Founda8on Plan,and SecBons-96-18039000.6.dwg,10.29.18,1:54pm,prakashb,96 mZmO O 2D V�O mZr Nm T 0- y > A O f) DO Ar/ AT Om C O N mmAm z 3 r/J 6yy? z z y O ° rrrrr� v m m a e 0 r 0 m9 O V OOyO O AZ �m20 rllm ZOO mm N O��O mrneA m Z �x1 odW N r zg c g� r� Ap m zr x A x 00 A z 3r zoz O na '1�v m<OA 6° g amoo Do my = m-m 6 zoo 0�1- O� G] �- -I O W�O A AS Amr T- m m C mm C6 r/1 O Z m - m m c,m mzF^m ° x m ti C mA ° m 2 z �Z � � Arc- m zy zzgm m m A �m Jmmm ?: 00� nn m s m =(A T Z mm N N my mmm g 00 o W 00 00- COOy00ril T ° O m� T aa y m r.�rrl i.+ �Z m 3.�- ��e9 m mmM Cfi v�O mmA Cm°n 8m0<�og Ap < aggros zsgms�gOm0 O� O � � vDAZm rJrZ m Xx�l D- O> - G7 m -Pzmr Cyi O �ONv�my mp y00� �AA m 1 A�n�Ym -atiyT c0 Cmb mCO c�5?rA NrmAp ti zoo �rIA�CAi ym Z �C �ryrlo o �00 r-ii�Am O�TgmovaZ FN'��Azy od �z D °.cZ `'a°'ny- F '� ° my O O -i-mm AI�Szz m W� ay C ~ < "� ooZ m2 AO Z mi m w m O zrx W-M ma UJ Oy mamA �- z � SCmpl. TAo_ mT < xr-om 3 N a Z m vO < 2 z0 m 0F8z Z � 0m zO o Ism<'I yO tiv � m Sy m [mmmpv m m fn oT a- 7� m me m zTAm m � - m�C m O y O z o 7t. m~A mm O 1yW m mOD Ozm me r�ii o F O tiv�CxA- W �mo v� min r�°IMMAWAR m ��i,�m yOm-� m Cs' D �g300 zm 1/1 y 0r m m o2 mA T2 m m A m yIy $y p 0 Hm OZ- A m0-grOA A�mC m W 1mO pyO O-aAoo N n O Z D D mO�m mAy Nyag°CZ (� pN fn yy OCZym 1Z12T C Zy q rW-nrrAIZT 5 yy mZ-I n0 Sm 2 m Z Zy DpZ Omg ° 2-'e�C O O p" m 0r AA <� O b m A m r.� z m Om Arp- F �' O -Amy00-Z 0 rn m;Kf�rO mrtriODmo� Om. C'mOZ 3 rt O Z D O[ ZmyDy .e °- D.O-O WW m O mONm�.! DAD§ 2 O r,9 O Z m RIp�T 3A-* Dy DC ryY mO mm Z0C O OA m m2o� N m0 O°!il mmZ omAZ-1 �p m OA N < OZ n'�ny p Z O �y C mDp marOT ti0„� D� ma OT-V m AOAff `4 Z y C W- ��02 D m m3:�F "A �m0 WW -1 rrtrII T vv A m A m r D C SS n,_ m Z C D > a O O p m0 mD Ar000o Z�mC 5m DOm `�;D pN D m0 Zm-io �Kr�vm�'mo Zoi <r DZ° O Z m.'AO_ ZF m r m O-i A O< A O i1 mmO �-o Z r1'I my0 O�'m a� A tir00- mDm mo2� C Z AZ O A Cm�Aa Zm O0'� C O J" gp T- A� �C� mXam° O m0 S §y aD JC �rlW Amy��I1p OZ gF� mOWCp�A��' m12m �mrt10 m(ii mF O D ay<Nm '�fArl;- Omp m Nm ma N m° m ?Tm m m O m0m mo H-06 G'Z.M Nil �mZD m m m m D O y -ii Z m p -i O I �Ic II�'9 z g D 01 8 oA �mA c Wo.•vvrrrlm rzOR ma<3Ci m 2 to To• czi c_z� " vg5 zvzi `o_g i mT1 In moyym m 9!I�g c75 o Z m C "T 3 >9 - v m m a 7C D m0 DD D 0p OzoA�" W m 22 m 2 Sx SXA mG ZOm yTm0 y2 A O T A_-1 tim m r' mvm 1 y mxA C' TO-m ZOy �'o-d+8 A. II+'c d o --IIc -I r� mL 2 Z9Z�� Oa Ar• AC mz x y O _Am c yf m0 om m�n O z- Yi�imm mS O ° aFA n �i� Mm >;ro Om m 2 , mmm,y m +W 5-1 � f.. Z za O -I O y � � Z A Zm8 X gv�Z r� A m' ec S.W-'C'Qg m`�-'.c3 D r a y O� mr`{ Z 00 Om T�2 ° Om O y< '!y m -1 =C =� DA �t1-e y� N A m A m� T � m-1 �6ZjZ (°-jN_O �A- m 3T m m $'S'� R i£�° SOT V��oO N C r0yn cm oyr�fi-rD- T ��II > �i' Z 2 Z O D D'o O -I m o°m _ 3 A O TT,� 2 y x � "( r K rr t0rl m m m im -11 O 'n "e Z r'r myI y qq T 02 CO-A+ "iAmO� g00 -${{ A,y9,yY KmAO 2r�2r � 2 JOm y2 <r yTy om '9� D ZOO 3 A D mo A(pp��OOmON mmy� 51 ZfA'1OZ�F go �'�_ /�.Y�.ZE os �m c Z y Z AD An0 �0a g 2m nI R1 ;D rmj m Omy ma°p A2x O� 2A mJc Z �ml--'d i Ai 2 ~� Z :' A = �m CZTDmn TryArl� °m-o2S�m m m °O� w n ��'e = ? e y O O pD my- A�yy Z� nt�rrrrlI O pmr W io2NZ mCC ym N Km 00 -I�O-2 m <--1 ti m <p AT Z Orr-��V1D -iAs.00 O D�77��A W 13 e' W O� m f� o m Ty O?� C r'CD >SmygyO ism gHTA I.Io-O NAWW p0 a o Wy = amm o i Zj A X�m H Z A N��rmG1 �Dmp 0M C O'OE°DAO Zvr DrAyom a '�'3 2 m AO m O20 m mmnyyl pp20 In�n -1 v m rfAtly$A i O:' TmD m 00A Z3ti0Aml mAOz AATmm OrmAO aZy yArAn 8m ApZj dr. 3 AOz S j AOgmg Am-iyZ m Q m aAO N<p �yN m A AO m 0m : Zi O"m 41 om O ?5x 8m O AT W A OD rA 3 II II G m 91 DD 2 m. Tm M(�MX z �I SIT D bi, x mr rr� '0 .'0 -a p m Z d1 gm fO�rl �ZA m Or Tyln �0 m T Z A;rNm0;1 pp - <ymA Nrm <m m Nm 'gym (A ZO-pe ZCZ2m i j ! m m ti rrl� m- �21" y W 7�g ADIDCmrr/ly 2rnA7C ,�, + fR«li y ••c��rr m m Sir1 NC.Cn mg2r� 0DWAm0 �7.1� °gti0yy 5R ppII m-. mA GZDN"I i O: v m a o 2O m mTDD `�; 5vm OyyZ Z �, Q O �y O Y ° 3 °D <�D �m 'i p WA2 ly rnm D N A -I �08 O- O T-m OA 0 m $tT2 E. .�II rrrr�� �tyy1 y ti m A e A A A m -I Z T 0 0 _ W fn- + m Oo-o yyyy yyyyyyyyyy W- -2 Ne m AW mu1ON- ti: m yyC O m 0 Z O,c' T O "gym rOy Oa3ri m°mm2 mUl Nram m(/JmgmZ zo'mm�m 'ID P' p �JJ O N�n01N m �I 0 O C ° Or ZAr A O m- H y _ A C 2rrIZ_--i m .--II--II-I -I mOCm m < �N N r- a A i ti: ! mI T y rmrI yy(Tmn �p DO D Z'mn O'nmZO yjA yAm +i 7 S <A Z ((nn OA ZA OSZ aaaa �m mC OZ O Or.{_g 2i DA N D3yA- AC poCr7 O-(� V -02 m g 5 r O yo {;m m m Cy ;C 21Am0>y O DZa W O 2 < v -4 Z�D10 m in ` 2 A Di mg Is, rr��AgN °AS TmA OZD T B N +o g m Z -I A C OZ mOC rA oDmDDDDDmmA <O-e�C DD CC O G' m N m2 0I y c L7 rzb; 2- (� O mO O 5' D m Q g A y Z O Z D m i T m c m 4I�f!pY��{{Sa Q y C N Z 2 > m N m K O A: H p A n +Z m Z �8 D 0�- F A(� A N a 1 $ yy yy +�y$+II�- S RZ_ Ooom 11 2a Z OT-{Fri-i O: A Oyy <N 0034� p ZZ Z� yC O is a s o -� D 2 A� S m C�In�C pN°mm 3+ °6p KAD° y m2 S O_ 2 32 mm Z: i m DZZZz m' n,zg Cl9 g �; 80 �nm;C�� m n �m 1n m m Z m mNN Z 2Z �0 0 m O2CC �C Z < N y ° °° N T C p$ OS5m0Z < .�92 rm/1r 4 tjl < 3i Z m mW T c o m� �cz� 8 m o x x m nm"�-o o: m °pm m-; i zD 2 00$ $ v o y op a`6m A'�mAm O§Cyz m mm yAmmyA mDi {y; 6 Amgmc v m5 v-zm? ay5 r7r A mm II m 0 8 Z. 2 06 A2 2a m Om Am rZ>GD) v 0 ti G OZF g LAj 47 G)z OOzr a FmOA trlm AA N o < N o Z A O-IO v m Am Z o�TmZ Am 0 m mT Sm Z �m m AOA. rmaam ° IAInnA ^9 O�m'1mmT T ym0 m- yy m- m m htOm 9 A COO N O A m D p DyCA �O MC - 3 D $ Zm . Z� 7.72<', AO'Ovm N v� yAAOp ym�0 A c x1 O 9nmrT AF �A m2o° D�frnnG czmr�Za ZyZ 2(C'j0 NO Z m_ ZD ?- ° m K z O 8 C O m0 O .��yyyy 5Z 'n Am [+fin yA r79�>cci. o-, y g .'0 ,EON O Do �Orn �O c41 AOg10 � � :m.. Z m0 KO m�WDp Crrl� O Ir19 Sm r~ b2F A m p D.Oy Tm y2O0�ON G1 g0 N� Om3 mmZFi��n g f2 �N °0$',^ O 0C A,�20i bN< lv T -Im2 0 m DO moms §� zo o € o m rmrII I' S ,"0 A frl O Z m yy X 0 T 0 N D W T 2 m rn- O-9rlr W mOW A y �mmA m m8O 4 Oyrb TfrIA N amp °mop = m =D FT mvmy r�Or 00 6 ADAOy Z1y m m D 'D xm~n mn >:NA rmrl2v pAm a�sm�ma ZmOZ°2 m A v0 eAm vmZZ DZ COCA �y 2 m z rp� In Fj yrmm hC +m2 N ;ti�m r� r m yym oAyT� zm<m C° _gpz5 a $ 4+ C yiATm� ° O Z�S' Him g;cl�Zzz m �b�Eo D Aq yyyyp((�� zFOg Cm W�T Drn y gZAT w m yy D D +I 2 7C A r-IT 9 Z� OOOOmA �❑❑ ti r�0 xy S• m O C.. mO v "r' 2 O.. Z omDW� mA Dr3A00 9 soZC 3 2a mm 'S'S'S b�'S �➢ �'m o mZ o 0 om a:m Tat A z c1A m fi yT ; mr m� o dlbmad� m c °$+ z a W + gaco 5 m mr �m gm z No o m 3 D-1 v Gz 8: nl ar, 13N wV v009 m A� p ° m m" Tm m r m r Smr Z�c SQSc QQ s D a Z+ rA h 'I O O �ti ry r'fi ry L1rZm 0008�� "' y F c A mmow^� KCpOAg �n myor-M 1 OOEM Dm mp OmmZ 8) NN4TiNNfT_/+ o+ m Z v 110 mj fmZsy °OcHm;2m ADam p1p av0i Z 2� W mm 0 L1 WA —o---- oo A O K �ymm? o OT m A�7J AD�ta OII yr zm vv. -I 2fn0 < B m *;E k«<5<�<c a ;+-1;+-1�u�v mz;smmzm� :.POOR ZZ3 err�xy ZTnm 2S 20m �. mmmm In tnm�nqp c�00nnmmmm y m p xo Zzry.�ATb f lnPPP ; ,ry. i pJ 9-tnr o;,r-r-g 0 . 0iE- o oboo FPP z`,P.+rn OZ. 3rr�_Auzo < yy z zN Z(�-0 �' Z tip b ',m<2' f�0y' Am Im gNp' g0 Win. C? vG1 mZ A. .m m 1 m = ACmNm� �AOm 71 o. A $ c y A nznA zDD�A�n 2mom A ar r m 6 A H c1� pm'lo� mczi$ ZZD1 IN O m� S � Z A m OOA�Zr OOOI" yOr0 cf p D O 2200ma TTS -I SZ 09; i -IWmWN WAAA5m�0000 ZZ OOO�ynZ�,Z ZOrnOi�ODg D9��02mSi���p�000�rprlO mCm(j p� O (1 Cmm 2`<m MOOM ca p>00 rDZ mg(q m--m mmmmmZ O- 000p O<2-12 mOmm AA -CiCZO DQ fDI fn -1 Z mmr C ti TrrO Am mm0�2-ititipAAA m00 p000 p09�InmZTI~rINNCm Nmllyn y ZCZ)00000r"-AiF,+gnFNCp T-i l�l ill((��m22 C0�iID 222 Cm ZCZ Z Day:1 2(A � 0 m20� mmr� yy 'ppb b rll S AO T m G 0 O O �NtiA Z 1 0_Om A �j ti '•I Z20 ry�[y�W�m�p 51 TT DAr OSZO .mmyo00ZOT2OTrr gm0_mOZZO>pOC - ZOOOO�W�my ZTm R5cAzx m<ZZZm A5 m- �y2mmm ryy 1 00m r7r�� D� rF2Df V trr�n-rnT IraInn AD ZOmQ A<CO mmmmn Cn00D•e•ppD c W tiara 0TN0T<T SS00(D'ip mmyZy �cm0pi m0 D 2 gmr A< pOOA W m OCp O 2 m AO OZZ !!nnO-iLsb TpD 0� m Mm m-Dly DADm OC<2KOm0mm0 Dy Ftip W22m mNm m Zr) -1 O V1 -000- rAm 20mTTO n0�-IZ �T'�fI rN $ W A rDI mID- O M�a Z 0 AZ m mAmO C OZA < �OZ Z p A 3 mp0 0 'AT.TN -fNrl y(m'1�Z j�K(A mA TO y�AO T xqr IInn Z O Z r�IT m m A_ Z ODC rr D O O y DW Zm A rTrl O�rD-W y 0 � sm pTm D O y 0 Z 0 D ZAON N Zm< Omy F A A y O F mAD m ryi2 D2 OCC A m v O oD m >mm ram r� Fob p v m i � < g °AZ D °m�0 Aa; zy1Z A `5 czim z m 59 o Z r9cm, z +N4) T pOi '8f N m�-Imy Amo y A -r A 0 D ms y Oy,� D 92Z�(�p °m(Zp fMo n �m n 2 A M*8 Z O ty/1mv tic �.. Z my Z m20y �Z 2y 2 m T 9 'OmT m <�Z-t OOIm- W!s-s I" 2Dp mz-mom Zr°Za° AF' zA g am g o n DH cNoZ C° Z AON c1 Z>Zg HF Z; -T gT y °O TAI OZOm O 0 y2y °� < 0O°z 0< mA rn ° m Sr Zf°n Zm 0 X S o r m y O m O O ram vmi0 z0 �S 00 m FZ o �o 00 2m A <O VI m3C� IV mxo� rn m~CZm m�nm 0<rArID �.r ommA O �/'� - m 0 mT '^ mA �A Z V/ 'I I <2 v, r3•$Wv m i�$mv HOLD C V' p C O�m g i o 1 1/2"CLR. m ;0 U rtr M M m m HOW La mEv LD -m OCn 4 1 112"CLR. z ' _ z z � -n c I11— D O a 7- Z •> I ri C m D L a .. m e .,v omA g .(1 4 Z o ,'a 2112 i�C D�s� ? m N o V7 Z nno n O c_' a 0z O A ",-•.• ` 9"• 8 Z A v 1 ` �Ajv p ry pCr°rl 0 _�"" inmm m W Z -mi e•,•. Ogg y a i 1 o Otn m..im TZNo5 + . ,." mo T m a OWD m a m m m II n�`1 Zzm !0x mms°� m W=rr, T li rn vm0 r A ''i..' S=~rm- N� ' �-Irn m mmo b ,T-z� b " 'O$� A x>t �Tmx m vmi F g m^�r�Ar j A zo C OAz o•m v 30'-0"VFY. "n T C I DL r- D z myN m o v v D �zof0m D� DTI N in + IV z 9UnDo0 czi'J C7�Amp� M z m _ ` m ro-f 30'-0"VFY. 0 m pmC o . A m o 'y I•-i i J m y ° i SHEET No. DRAWING REVISIONS DATE No. DRAWING SUBMITTALS DATE g m coNTENrs GENERAL NOTES,FOUNDATION PLAN,AND SECTIONS o rn z O .r ,et SUBMIT FOR PERMIT 10-30-2018 V p ONW STRUCTURAL '���titi SUBMIT FOR BID --� ARLINGTON MILLS PERSONNEL BUILDING ENGINEERS SUBMIT FOR CONSTRUCTION Engineers Northwest Inc.,P.S. r 19406 68TH DR, NE 9725 Third Ave NE,Suite 207,Seattle,WA 98115 $� gA ARLINGTON, WA 98233 Ph:(208)525-7560,Fax:(206)522.6698 "essloapL ` wwwangineamnw.com - LATE SIGNER 10.29-2018 C:\Users\prakashp\appdata\local\temp\AcPublish_4352\Adinglon Mills Personnel Building-S2.1-Roof Framing Plan and Sections-96A8039000-6.dwg,10-29-18,1:54pm,prakashp,96 F- a�`^ y0 m�00 VJ Z \ rpm A �_ z Zm M i 2 3m y0 ~ '-6 MAX. ' = 1 — I � CD Z I I, I I II � //�� VJ vw ° 'o0�0 lot [$w, Nxn>t Hm IZ I I mm 7 f FTC o M mii C n A n m 07 II mV1 z MW#vt 0 N ° M V1 4 � N T ! - r V^ v J k °m G, o� m3 m a <3 0 Z o A m C' �$$$��� v c In A --r--f �_ z Z£ Z Z L� m T` '9 �_ � d. z co y 3 0 Z 2 1' O M 1T) C� Z z . O IIii o 0 Z �L g 2'-8 MAX. 0','z Z pm'.I m J mmC V m �7K G) m 'Op x a x.m m ° D A ti-0 O � @Om M T< 0 =Z O itMm I y 30'-0"VFY. _—_ -___-,_ T -- _—___ O N D & � ^Z^ CCZ T r zzm V m ZZ F. � z o� Z M-, ELI r ❑� o — �_�_.__.�._ _._ o Z fv — — (E)PURLIN {f_t PURLIN (F PURI..IN r_ 30'-0"VFY. J i o ° z W SHEET NO, DRAWING REVISIONS DATE NO, DRAWING SUBMITTALS DATE m z Z corlreNITS: ROOF FRAMING PLAN AND SECTIONS z m Q "�' SUBMIT FOR PERMIT 10-30-2018 O A yYeY p W STRUCTURAL �.? • �e SUBMIT FOR BID N 8r N N o ARLINGTON MILLS PERSONNEL BUILDINGWENGINEERs - SUBMIT FOR CONSTRUCTION rn Engineers Northwest Inc.,P.S. 19406 68TH DR. NE _ - 9725 Third Ave NE,Suite 207,Seattle,WA 98115 ARLINGTON, WA 98233 Ph.(206)525-7560,Fax:(206)522-6698 www.enginsersnw.com DATE SIGNED 10-29-�018 —